SK-901 & SK-901b user guide

Page 1

USER GUIDE Model SK-901

& SK-901b (Pedi-SK4)

Luxury Whirlpool Pedi-spa Chair


TABLE OF CONTENTS Cosmetronic Warranty Information …………….…................................................................. 2 Cosmetronic Warranty Information …………….…................................................................. 3 Introduction ………………………………………….…................................................................ 4

Important Safety Instructions................................................................................................. 4 Important Safety Information .................................................................................................. 5 Important User Requirements................................................................................................... 6 Health Risk Warnings.............................................................................................................. 4 Pedi-spa Specifications ........................................................................................................... 7 Handset Operation.................................................................................................................... 8 Chair Layout ……...................................................................................................................... 9 Basin Components ………........................................................................................................ 10 Product Usage ……….................................................................................................................. 11 Cleaning Procedures …………................................................................................................. 11 Cleaning Procedures …………................................................................................................. 12 Trouble Shooting ……………………………………………………………………………………… 13 Notes & Contact Details …....................................................................................................... 14 Documentation ………………………………………………………………………….………….... 15

Assembly ………..……………………………………………………………………….………….... 16


Cosmetronic Limited Warranty Cosmetronic UK Ltd ("Cosmetronic/we") conditionally warrants your pedicure spa chair (the "Pedi-spa") in accordance with the terms and conditions set forth below for a period of one (1) year commencing from the original date of shipment (dispatch) of the Pedi-spa, to you. The warranty only applies to the Pedi-spa's original end-user owner – ‘you’ (the "Customer"). This Limited Warranty is non-transferable and replaces any warranties previously published by Cosmetronic UK Ltd for this Pedi spa chair product. Should examination of the Pedi-spa be necessary by C o s m e t r o n i c o r i t s a u t h o r i s e d a g e n t during the applicable warranty period, and this inspection shows it to have a defect in material or workmanship, Cosmetronic will - at its option, repair or replace the defective component or part thereof. Furthermore, C o s m e t r o n i c may at its discretion repair or replace a defective part or component with a refurbished part or component. In some circumstances, we may replace the Pedi-spa, where necessary with a refurbished Pedi-spa. If Cosmetronic elects to replace the Pedi-spa for whatever reason, the replacement pedicure spa w i l l be comparable in style and size to the original Pedi-spa supplied “subject to availability” but may not necessarily be identical in colour or model. You may at your discretion reject such a replacement, but should note that extended repair times, could be incurred, due to parts availability and shipping times. ‘’You” the customer shall bear responsibility for all charges incurred for the return shipment to “us”, and all subsequent shipping costs for the return of it - to “you”, or equally the shipping costs for all replacement components or parts, and the cost of a n y labour incurred in repairing the Pedi-spa that are not covered by the manufacturer’s warranty terms & conditions, to include, but not be limited to, the repairing or replacing o f any components or parts on or off site. The foregoing limited warranty does not apply: • • • • • • • • • • • • • •

To the Pedi-spa, or any components or parts thereof, if subjected to misuse or neglect, or accidental or intentional damage. To the Pedi-spa, or any components or part thereof, if altered or modified in any way. To any expenses incurred by “you” or any third party, including labour or materials charged during the investigation process, removal or reinstallation of the Pedi-spa or any of its components or parts. To any damage o r impairment of the Pedi-spa or i t s f u n c t i o n s , components or parts thereof, caused by any casualty, including without limitation, accident, fire, wind, floods, acts of nature or attempted theft or any other form of force majeure. To any workmanship of a fabricator or installer of the Pedi-spa (other than Cosmetronic). If damage to pump parts and/or motor parts is due to partial of fully obstructed plumbing. If the Pedi-spa is re-sited or removed from its place of original installation. To staining, fading, or discolouration of any portion of the Pedi-spa caused by water additives or improper water treatment or use. To staining, fading or discolouration of the Pedi-spa's upholstered seat, armrests or footrests caused by incorrect cleaning or improper use of chlorine based products. To malfunctions or damage caused by improper installation or maintenance of the Pedi-spa, including but not limited to, failure to comply with local, regional, or national plumbing and electrical building regulations and practices. To damage resulting from a person standing in the Pedi-spa's basin or other similar stress damage caused to that basin. To freight damage incurred outside of ‘in-house’ delivery service. To damage incurred to the Pedi-spa while in possession of any 3 r d party, other than Cosmetronic UK. To any damage incurred through use of excessively high water temperature, higher than the manufacturers recommended guidelines (over 65°c) for safe usage.


This forgoing conditional limited warranty is also conditional upon: • The Pedi-spa being installed by a licensed or approved professional in accordance with •

Cosmetronic's recommended installation instructions. The proper use of cleaning and sanitising solutions in accordance with the instructions p r o v i d e d by Cosmetronic. Repeated use of a n y concentrated b l e a c h o r o t h e r chlorine b a s e d chemicals will void this limited warranty. NEVER allowing the use of a n y ionic array (detox) devices or machines that subject any o f t h e metallic parts to reverse electroplating; any use of such devices will destroy plated parts and void the limited warranty supplied. Shipments to Cosmetronic if requested, of Pedi-spa parts or components thought to be defective. A n y p arts or components may only be returned i f a u t h o r i s e d in advance by Cosmetronic (with written or email RMA, ‘Return Material Authorisation’). Any outward or returns cost must be prepaid prior to any collection/dispatch. Acceptance of Cosmetronic’s appointed couriers terms & conditions of carriage are agreed to by you, at the time of initial dispatch or, for any subsequent return or replacement reasons, unless agreed otherwise by Cosmetronic. Determination by Cosmetronic or its agent, at its reasonable discretion, that there exists a defect in any materials or workmanship.

Repair or replacement of any part or component under this Limited Warranty, or even t h e replacement o f a Pedi-spa, shall not extend the duration of the warranty with respect to a n y such repaired or replaced parts or Pedi-spa ‘beyond’ the o r i g i n a l l y stated warranty period. When a part or component is replaced, it will be under a warranty period o f 90 days, or for the remaining lifespan of t h e original warranty, whichever period is greater. You - the ‘customer’ agrees by using the Pedi-spa that: • The obligations of Cosmetronic shall not extend to any claims of direct or indirect consequential loss or damages, or any injury which may result from such use, including any circumstances beyond the reasonable control of Cosmetronic or its appointed agents to include, but not be limited to any momentary lack of human, parts, or technical resources. • That the obligations of Cosmetronic are limited to those set forth herein. • This warranty is limited to the original owner/end-user and is non-transferable. • Cosmetronic shall not be liable for any other obligations or liabilities, including-but not limited to: obligations or liabilities arising out of breach of contract or warranty, negligence, or other tort or any theory of strict liability with respect to the Pedi-spa or parts or components thereof, or any acts or omissions of Cosmetronic or its agents. • Any assistance by Cosmetronic provided to you outside of i t s terms & conditions, limitations, or exclusions of this limited warranty will not constitute a waiver of any type, of the foregoing terms, limitations, or exclusions, nor will such assistance extend or revive the original warranty terms & conditions. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. NO DEALER, SALES AGENT, OR OTHER THIRD PARTY SHALL HAVE ANY AUTHORITY TO BIND COSMETRONIC TO ANY CHANGES OR ADDITIONS TO THIS WARRANTY OR ITS PRODUCTS. ACCORDINGLY, COSMETRONIC IS NOT RESPONSIBLE FOR ANY SUCH EXTERNAL OR THIRD PARTY WARRANTIES OR REPRESENTATIONS. IN NO EVENT SHALL COSMETRONIC BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER TO INCLUDE, BUT NOT BE LIMITED TO LOSS OF PROFIT, REVENUE OR GOODWILL, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PEDICURE SPA OR ANY COMPONENTS OR PARTS THEREOF FOUND TO BE DEFECTIVE. THIS L I M I T ED W AR R AN T Y G I V E S T H E C U S T O M E R S P E C I F I C L E G AL RIGHTS. YOU, THE CUSTOMER MAY ALSO HAVE OTHER L E G A L RIGHTS WHICH MAY VARY BY REGIONAL OR NATIONAL JURISDICTION.


Introduction Thank you for p u r c h a s i n g y o u r S K - 9 0 8 p e d i c u r e s p a c h a i r f r o m C o s m e t r o n i c U K L t d . T he S K 4 ™ range of pedicure spa chairs (referred to as t h e Pedi-spa) is a highly innovative piec e of professional salon/spa equipment that has been specially manufactured for Cosmetronic UK Ltd and supplied to serve you with dependability and productivity for years to come. Please take the time to thoroughly read this entire user guide before installing or using the Pedi-spa. If you have any queries or questions regarding your Pedi-spa, please contact C o s m e t r o n i c s a l e s & technical support team on 0(044)1322 290101, Monday to Friday between 9am to 5.30pm GMT. All calls made outside of these hours should be left on the answer phone service, leaving your name, contact number, invoice number and Pedi-spa product or model code. All recorded calls will be responded to at the earliest opportunity.

IMPORTANT SAFETY INSTRUCTIONS When using any electrical appliance, basic precautions should always be a d h e r e d t o , a n d t h e s e b a s i c p r e c a u t i o n s s h o u l d a l w a y s include the following: Please read carefully all instructions below before installation or using the Pedi-spa. WARNING – To reduce any risk of injury by scalding, fire or electric shock, you should: 1) ONLY use the Pedi-Spa only for its intended use and design limitations as described in this u s e r g u i d e . Do not use attachments, products, or accessories not recommended by the manufacturer. 2) NEVER operate the Pedi-spa if it has any damaged cables or plugs, or should the Pedispa not be functioning correctly in any way, or if the plugs/handsets have been dropped or damaged, or immersed in water or any other liquid. 3) NEVER fill the foot basin with hot water only! Always half fill with cold water, and then introduce hot water and mix to desired temperature. Never use a hot water supply greater than 65°c. 4) NEVER drop or insert objects into any openings in the chair or its base unit. 5) NEVER use the Pedi-spa unit outdoors or in an excessively moist or humid environment. 6) NEVER s i t e o r u s e t h e P e d i - s p a where aerosol (spray containing alcohol) products are being used (spray tanning), or where p u r e oxygen is being administered.

Save these instructions


Caution 1) NEVER use any pins or other metallic fasteners on the upholstery of the Pedi-spa chair. 2) Carefully examine the upholstery covering and foot basin before each use. 3) Discontinue use of the appliance if the covering shows any sign of deterioration, checking, blistering, or cracking, or any other type of damage or deformation to the Pedi-spa foot bowl. 4) NEVER use the unit if there are any visible signs of water or waste leakage. 5) KEEP DRY – Do not operate the unit in wet rooms or moist/humid environmental conditions.

Warnings 1)

WARNING: To avoid risk of electric shock; do not permit the usage of any corded-m ains supplied electrical appliances within 1.5M of the Pedi-spa footbath (such as hair dryers, lamps, telephones, radios, or televisions) 2) CAUTION: If the unit is used without a mains ‘RCB’ fitted power supply, you should purchase an inline ‘RCD’ (a safety circuit breaker) before using the Pedi-spa. Any such device fitted (RCD) should be regularly tested as per the manufacturer’s instructions. 3) C A U T I O N : Temperatures sufficiently high to cause scalding (from hot water supply) may occur regardless of the mixer control settings, if used unsupervised. Please observe the following points below: a. Do not use on… • Infants • Invalids (where user cannot remove themselves from the spa bowl or chair unaided) • Sleeping or unconscious persons. b. Do not use on… • Persons with insensitivity or hyper-sensitive of the skin. • Persons with any known history of poor blood circulation (may include pregnancy). • Persons with any dermal disease, infectious or otherwise. NB: regularly check all areas of skin in contact with the hot water/basin area of the Pedi-spa to reduce any risk accidental scalding or blistering of the feet or legs. 4) Excessive water t e m p e r a t u r e s are dangerous and s h o u l d b e c h e c k e d p r i o r t o e a c h c l i e n t use. Maximum operating water temperature (for client comfort and safety) should not exceed 107°f (42°c). The maximum supply water temperature should not exceed 149°f (65°c). 5) The P e d i - spa chair has an inbuilt v i b r o - u n it in the seat base. Persons sensitive to this type of relaxing vibration should be careful when using the Pedi-spa. 6) Always enter and exit the pedicure spa slowly and carefully. 7) Never operate any electrical devices in (the water bowl) or near the Pedi-spa chair. 8) This pedicure spa has a maximum weight capacity of 150kg (or 330 pounds). 9) Do not crush the upholstery and avoid sharp folds or creases in the material 10) Do not stand on, or in appliance where possible. 11) Use only whilst seated. 12) Not for use by children! The Pedi-spa must only be used by adults and never unattended. 13) Keep children away from the electrical or water functions of the Pedi-spa chair, including the taps and foot support systems. 14) Connect this appliance to a grounded mains outlet supply only. Consult your installation instructions or your appointed installer if unsure. 15) Never allow post operative clients to use the massage system of the Pedi-spa chair. 16) A comfortable water temperature for use in the Pedi-spa foot bowl should be between 38°c to 42°c, for client comfort and safety. If temperature monitoring facilities are not available, ensure the hot water ‘supply’ is limited to no greater than 50°c (Consult your installer if required). Always cold fill the foot basin with cold water first, and add hot water to mix until the desired temperature is achieved. Note: For safety always verify the correct water temperature range is adhered to, before each use.


IMPORTANT USER REQUIREMENTS Cosmetronic requires (for manufacturer’s warranty compliance) that you appoint only industry accredited plumbers/electricians to p e r f o r m t h e installation process of your newly purchased Pedi-spa chair. Recommend installer’s details can be provided on request, but may prove more expensive than local accredited tradesmen due to travelling distances involved. The Pedi-spa installation must be in compliance with all of your local and n a t i o n a l plumbing and electrical building r e g u l a t i o n s . Your Pedi-spa cannot operate efficiently or safely, unless it is provided with an adequate and stable power supply, sufficient water pressure, constant (regulated) water temperature, and the required drainage facility. It is your responsibility to contact your local council building inspectorate for information regarding the specific local compliance regulations in effect that must be adhered to prior and during the installation of your Pedi-spa chair. Any subsequent inspections or approvals that may be required due to regulation changes are your responsibility. All extended warranty packages or maintenance contracts can be purchased at the time of sale, and are conducted by our approved third party warranty & maintenance team, details are available on request.

HEALTH RISK WARNING Individuals whose feet or legs are inflamed or have any open wounds/sores, or any communicable skin complaint should not be allowed to use the pedicure spa at any time. All users/technicians should advise clients to consult their physician before using the pedicure spa if there is any sign of fungal infection, swelling, fracture, or persistent pain. In some cases diabetics may experience improved circulation in their feet, but should first consult their doctor prior to receiving a pedicure. If the client experiences any pain or discomfort d u r i n g n o r m a l u s e , discontinue the t r e a t m e n t a n d use of the pedicure spa immediately. Your client’s massage and Pedi-spa experience should always be safe, pleasant and comfortable.


PEDICURE SPA SPECIFICATON ½” - 15mm Hot and cold water supply lines are required (hot and cold ‘inline isolator/ball-o-fix valves’ are recommend to be installed (just before/prior to the connections at the rear of the Pedi-spa base unit.) It is also advisable (for hygiene purposes) to install an ‘non return/one way valve’ to the Pedi-spa waste outlet system. Consult your installer for further details SHIPPING INFORMATION Seat collapsed : L (102 cm) x W (57cm) x H (72cm) Base dimensions : L (154 cm) x W (64cm) x H (57cm) Stool carton : L (40 cm) x W (40cm) x H (50cm) Weight : 257 lbs. (117 kg) – Combined total all 3 cartons & packaging PEDI-SPA INFORMATION Overall dimensions, armrests down, with seat upright and forward : L (154cm) x W (57cm) x H (145cm) Overall dimensions, armrests open w/ cup holders exposed, seat upright and forward : L (154cm) x W (117cm) x H (145cm) Minimum area required for full chair and armrest movement : L (195cm) x W (117cm) x H (145cm) Dry weight (complete) Water Fill Line Capacity Whirlpool pump motor Seat upholstery

: 198lbs (90kg) : 17 litres or 4.5 U.S. gallons max : 220-240v : 1/6 hp, 50/60Hz : Polyurethane (PU)

Seat and back motors Roller Massage motor

: 24V DC Linear Actuators (where applicable). P edi -s pa chair requires 17” (44cm) of space between seat back and wall, to allow free movement for adjustment. : 12V AC, Adapter/transformer included

Power source

: 220-240v AC, 2.75 Amps, 50/60 Hz

Warning

: The Pedi-spa must be installed by a licensed electrician/plumber, and conform to all local and national electrical & plumbing regulations in force at time of installation.

Construction

:Metal Frame with Acrylic outer shell and basin, pre-plumbed.

Whirlpool system

: Uses 2 water jet massage channels, no closed loop circulating pipes, making them easy for cleaning and sanitisation. : main On/Off switch to rear of seat for massage unit and seat vibro unit. Fused plug mains, for massage pump system and whirlpool On/Off switch situated in unit base. Separate button operated power-drain pump for basin drain (where option is purchased at time of order). : Tested in accordance with, and found in compliance with the requirements of EN60335 1:2002+A1:2004+A11:2004+A2:2006+A12:2006+A13:2008 and EN 60335-2-32:2003 : This unit may lose one or more functions when power surge in excess of 2KV is applied to the AC input power port and can be restored by replacing the fuse to the main seat switch housing. : One (1) year on parts from date of shipment. Labour, travel, service or freight costs are not included.

Electrical switches

CE Compliance Electrostatic Limits Limited warranty

NB: Due to the manufacturers policy of continuous improvements, all specifications may be subject to change without prior notice. All dimensions and weights are approximate.


Handset Layout LCD Screen Power/Auto On/Off Button

Set Vibro On/Off Button

Neck Massager On/Off Button

Neck Massager Direction Button

Back Massager On/Off Button

Back Massager Direction Button

Backrest Raise Button

Backrest Lower Button

Seat Slide Backward Button

Seat Slide Forward Button

Time Set Function Button Backrest Button Controls the incline Movement

Calf Raise/Lower Button Controls the Forward/Backward Movement

Please note: Pressing the handset buttons using finger nails will cause damage to the handset. This damage is not covered by your manufacturer’s warranty, and it is therefore suggested that you use the ‘pads’ of the finger tips to prevent this from occurring.


Chair Layout

S

Neck rollers

Shoulder rollers

Back rollers

Waist rollers

Flip up Cup holder

Handset holder pouch Massage rollers (Inspection zip flap behind upholstery) Fold up armrests Seat Skirt (Cover frame work)

The handset should be stored in its holder pouch when not in use. The massage roller inspection flap may be removed by removing back upholstery from its Velcro securing point on the top rear of the seat back. You can then gain access to the roller massagers by unzipping the inspection flap. The armrests fold upward (dependant on chosen model) for easier access to the chair, allowing client seating from either side.


Basin Components

This is the basin layout showing most of the components that make up the user functions of the Pedi-spa chair. The picture left shows the left & right feet support for the customer to rest their foot on whilst having their treatment. Visible at the top of the picture is the multi-coloured LED lamp used in conjunction with the whirlpool function to give light therapeutic relaxation during the soak element of the customers pedi-treatment. The remaining components are shown below for your easy viewing.

To the right is the main inlet ‘MIXER’ tap. To use, simply Lift to allow water to flow. To cease water flow, simply Push the lever down until it stops. When filling the bowl It is recommended to semi fill the basin with cold water Initially and then add hot water to mix to the desired Temperature (see operational & safety guidelines pages 4-6)

-

The Picture Left, shows the following components, All which are explained in further detail on the next page.

Shower head Plug drain lifter Pipe-free whirlpool pump Waste plug


Basin Components The main On/Off buttons shown left, are vacuum operated switches for the whirlpool function and the power drain function. The power-drain function is available as an option and may not be on your SK-901 Pedi-spa chair, depend on the version you have chosen (a/b or c). To operate, simply push to activate (once plug is open) and then push again to deactivate.

POWER DRAIN

WHIRLPOOL OPEN

The image to the right shows the pipe-less whirlpool massage system used in your Pedi-spa this is the industry preferred type of circulator due to its inherent advantages for greater hygiene, simplicity and ease of cleaning. To open the circulating pump for cleaning, simply twist the outer casing in a clockwise direction, as shown. After cleaning replace the outer case and tighten by turning in an anti-clockwise direction.

CLOSE To open the basin plug, turn in an anti clockwise direction you may then start the power drain. Once the basin is empty, switch off the power drain and then close the drain plug in a clock wise direction ready for the next fill and treatment.

The shower head handset may be withdrawn from its holder up to a length of 500mm for easy wash down. You may change the output of the shower head by switching from ‘shower spray’ to ‘single jet pour’. To switch between the two outputs, simply click the headset switch to the left or right, for the desired output.


Operation It is advisable to ‘pre-fill’ the Pedi-spa basin prior to client use to ensure the correct operating temperatures are obtained for safety reasons, prior to the client entering the water. This can be done prior to the client being seated, or by ensuring the clients feet are on the foot rests at all times during filling, and you should only allow them to place their feet into the hot water once you ‘the operator’ are satisfied that the temperature is correct. Once the client is seated you may pass them the handset for operating the seat massager unit. They can then select their desired area and style for massage. For ease of use they can simply select the ‘auto’ function on the handset, which is a preset timed & massage program. Once the client is seat and comfortable, and their massage is under way, you may introduce the appropriate treatment ‘products’ to the basin and begin the whirlpool massage function by pressing the whirlpool power button (see basin guide). Always ensure ‘non-foaming’ products are used (see safety guide) to prevent accidental overflow from the basin. Once you have conclude the ‘pedicure’ treatment, turn off the whirlpool massager (see basin guide) and open the plug drain. Once you have opened the plug to allow outflow, you may switch on the ‘power drain’ (when fitted) to commence evacuation of the waste water. Once the basin is completely empty, switch of the power drain by pressing the switch again, at which point you will hear the power drain pump go silent. Always ensure the whirlpool massager and power drain pump are not left running whilst the basin is empty. This is to prevent any accidental damage to your Pedi-spa components due to ‘dry running’, which will not be covered under the manufacturer’s warranty conditions. Before the client is dried and leaves the seat position, always ensure the chair massager function is switched off. Firstly switch off the auto/power button on the handset. If the chair is not to be used again for some time, switch off the power to the chair using the power button on the rear of the seat back. The chair is now ready to be cleaned for use again, by the next client. Once the chair has been cleaned and sanitized (see easy cleaning guide) record the cleaning details in the Pedi-spa cleaning log, ready for inspection should it be requested. It is not always mandatory to keep cleaning logs, but we suggest that you contact your local authority to confirm you regional requirements regarding this issue. Even if you are not legally required to keep a cleaning log, we highly recommend that you do, to ensure a regular cleaning and sanitisation regime that will ensure continued trouble free service. In any cleaning record log, always record cleaning activity for post treatment; end of day, and for weekly ‘deep clean’ procedures. All operators should fully acquaint themselves with the functions, cleaning procedures and safety aspects of the Pedi-spa whirlpool chair prior to any use. Adherence to the manufacturer’s user, cleaning and safety guidelines will ensure years of trouble free treatments for you and your clients. It should be noted that the more effective your cleaning and maintenance regime is, the greater the longevity of your pedicure spa chair will be. Failure to follow the manufacturer’s guidelines for usage and cleaning will result in a decrease to the serviceable lifespan of your Pedi-spa and may also invalidate your manufacturer’s warranty terms and conditions if discovered on inspection, which in turn, could ultimately prove costly for you to rectify.


Pedicure Product Usage Guidelines Due to the vast variation of available pedicure products on the market, it is difficult to list all of the known products that are safe to use in your pedicure spa. However, the following general guidance notes should be followed to ensure safe usage and to avoid damaging your Pedi-spa: • • •

• • •

It is your responsibility to obtain, acknowledge and implement your local, regional and national hygiene regulations regarding the Pedi-spa cleaning and disinfecting requirements. Do not use any type of products containing foaming agents; these will cause excessive foam build up and may result in ‘overflow’ or damage to your chairs internal pumping and electrical systems, and voiding your warranty. Through manufacturer testing it has been determined that products containing nondissolving abrasives (such as sand and sea salts) should not harm the internal component structure of your pedicure spa as long as the entire cleaning procedures required by the manufacturer are followed without deviation. Oil based products may be used in your pedicure spa as long as the cleaning procedures are fully complied with. Please use pedicure products and cleaning solutions in accordance with each manufacturer's directions. Never use any form of acetone or acetone based fluid for internal or external cleaning and sanitising.

Cosmetronic approved Pedi-spas will give you many years of service as provided the proper safety and user precautions are adhered to with regards to precise cleaning and operating instructions are followed. It is the responsibility of the pedicure spa user/owner to properly clean and maintain the pedicure spa to ensure full warranty compliance.

Easy cleaning and disinfecting of your Pedi-spa system Always check with your health & safety/trading standards department for compliance with the required cleaning and disinfecting procedures. It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in good working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection. To clean your pedicure spa, follow these 3 easy steps.

(A) Procedures for Cleaning and Disinfecting Pipe-Free Pedicure spas After each client use, each Pipe-Free Pedi-spa m u s t b e cleaned and disinfected in the following sequence: (1) All water shall be drained from the spa basin. (2) Remove 2 piece inlet housing & impeller. (3) Scrub all visible residues from the inlet housing, impeller, inside walls of the basin, and/or other components and the areas behind or under each with a clean brush and liquid soap (labeled as such on soap product) and water. Then rinse with clean water. (4) Then reinsert the properly cleaned inlet housing & impeller, (5) Refill the basin with clean warm water and circulate (pump through system) the correct amount (read manufacturers label for mixing instructions) of the local authority approved liquid disinfectant, which the product label confirms is a bactericide, fungicide, and virucide, and then circulate through the basin for at least 10 minutes. (6) Drain, rinse and then wipe the basin dry with a clean disposable paper towel. (7) It is advisable that this procedure is recorded in a pedicure-cleaning log. The log should contain the date and time of each cleaning, initials of the person who completed the procedure, and indicate which product was used for sanitization, and that the cleaning was performed after client use, ready for the next customer to inspect upon request.


(B) End of Day Procedures for Cleaning and Disinfecting At the end of every day and after performing the procedures provided in subsection (b) (1 through 6) and after the last client, each pipe-free pedicure spa shall be cleaned and disinfected in the following sequential manner: (1)

Fill the foot basin with warm water and detergent (mixed as per the manufacturer’s instructions on product label) and circulate through the spa system for at least 10 minutes. (2) Drain the detergent solution and rinse the basin with the shower head and then drain. (3) Refill the basin with clean water and add the correct amount of local authority approved liquid disinfectant, (read the manufacturers label for mixing instructions) which the product label confirms is a bactericide, fungicide, and virucide agent, and then circulate through the basin for at least 10 minutes. (4) Then drain, rinse, and wipe the basin dry with a clean disposable paper towel. (5) Then allow the basin to dry completely. (6) Then, record this procedure in the pedicure-cleaning log. The log should contain the date and time of each cleaning, initials of the person who completed the procedure, and indicate which product was used for sanitization, and that the cleaning was performed after client use, and shall indicate that the cleaning was conducted at the end of the day, ready for immediate use the following day.

(C)

End of Week Procedures for Cleaning and Disinfecting

At least once each week, after completing the procedures provided in subsection (B, 1 through 3), the disinfectant solution should be left in the pipe-free system of the Pedi-spa should not be drained until the following sequence of procedures has been followed: (1) The whirlpool system should be switched off, allowing the disinfecting solution to be left in the unit undisturbed for 6 to 10 hours (normally overnight, so as to prevent any down-time during working hours). (2) After the disinfectant solution has been sitting between 6 to 10 hours, rinse t h o r o u g h l y w i t h c l e a n w a t e r and wipe the basin dry with a clean disposable paper towel. (3) Then-record this procedure in the pedicure-cleaning log. The log should contain the date and time of each cleaning, initials of the person who completed the procedure, and indicate which product was used for sanitization. The log-containing the details of the cleaning after each client use, end of day cleaning and end of week cleaning, should be readily available for inspection by clients or for local health authority personnel upon request. Not all regional authorities stipulate maintaining cleaning compliance logs. However, we strongly advise you to maintain some form of cleaning log for your own peace of mind. Non compliance with these procedures (see section 3 if cleaning logs are mandatory by your local authority) may result in an administrative fines, and or prosecution against you should you fail to provide the cleaning log information when requested to do so by your local authorities.

CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Be sure to only use only non-abrasive products to clean your spa.


Troubleshooting Chair massager fails to start

Whirlpool does not start

Confirm mains power supply is switched on at wall socket

Start pedicure procedure

Confirm mains power supply is switched on at wall socket

Confirm main on/off switch is on, at rear of chair back

Start pedicure procedure

Check fuse in mains plug of base unit and replace if required

Check fuse in mains plug of chair unit and replace if required

Start pedicure procedure

Contact technical support for further information and advice

Check fuse in the on/off switch on chair back and replace

Start pedicure procedure

See last page for contact numbers

Confirm handset control is connected to chair correctly

Start pedicure procedure

Contact technical support for further information and advice

See last page for contact numbers

For all other issues contact Cosmetronic Sales & technical team using the details on the last page of this user guide. If you have purchased your Pedi-spa chair from an authorised agent or reseller, please contact them in the first instance for technical support or further advice.


Notes & Contact Details


Documentation Congratulations and thank you for purchasing the SK-901 series whirlpool Pedicure Spa chair. Your choice of Pedi-spa is a reliable, safe and easy to use piece of professional salon equipment manufactured exclusively on your behalf. The SK-901 Pedi-spa is designed to give a luxurious whirlpool treatment to your pedicures, giving your clients an overwhelming feeling of relaxation during their visit to you. The Pedi-spa is only for use by trained beauty or medical professionals. The Pedi-spa must never be used for any purpose other than its intended design & limitations. It is important that you read this user guide in its entirety and retain it for future reference. Should you need to contact us regarding your purchase of this product at a future date, please make a note (in the space below) of the following information upon arrival of your Pedi-spa, as this information will expedite any communication with our after sales or technical support staff, should it be required.

SALON NAME _________________________________________________________________

FULL NAME OF PURCHASER ____________________________________________________

MODEL OF EQUIPMENT ___________SK-901 Pedi-spa_______________________________

DATE OF PURCHASE __________________________________________________________

INVOICE NUMBER _____________________________________________________________

Contact your dealer on ________________________ or

Cosmetronic UK Ltd 76 Spital Street, Dartford, Kent DA1 2DT. T- 0 (044) 1322 29 01 01 F- 0 (044) 1322 29 00 11 E- info@cosmetronic.com W- www.cosmetronic.com


Assembly Guide Chair Assembly 1) Take the seat base section from its packaging and locate

2)

3) 4)

5)

The Chair is now ready for use

over the 4 corresponding fixing holes on the base unit. Ensure the seat is ‘forward’ facing and then insert the four mounting bolts and securely fasten the seat to the base unit. Remove cotter pin from chair base unit and keep close to hand. Place seat back into side locating slots and drop down into position. Next, align seat back to mounting point on chair base and insert cotter pin to hold in position, and then reinsert safety cir-clip to secure. Locate connector leads on chair back marked ‘A’, ‘B’ and ‘C’ and ensure they are freely accessible. Next locate the connector leads on the seat marked ‘A’ , ‘B’ and ‘C’ and ensure they are freely accessible. Connect all leads to their correspondingly marked opposites, A to A, B to B and C to C. Then plug in the hand control set and the chair is ready to be plugged in and used.