Odin® Foam Division, W.S. Darley & Company
Odin Diesel Mongoose 46/23 Specificationi ®
This model provides a “self-contained” diesel powered “slide-in” type Compressed Air Foam System (CAFS). The CAFS shall be designed to fit into the back of a standard length and width pick-up truck or fire service body. The CAFS shall be designed to discharge water only, air only, foam solution only or compressed air foam from the same discharge outlet. In addition, the consistency of the compressed air foam (expansion ratio), wet/dry shall be fully adjustable. Engine The power to drive the system shall be provided by a Kubota model DH 902, liquid cooled, indirect injection, naturally aspirated diesel engine. The heavy duty rating for this engine is 24.8 hp @ 3600 rpm. Automotive engines or ratings will not be used. The power unit shall have re-borable crankcase of grey cast iron.. The pressurelubricated engine shall have a 12VDC – 40 amp alternator, glow plugs. A remote oil drain shall be supplied. Water Pump The water pump shall be a Darley 2BE single-stage centrifugal pump with a vertically split aluminum case. It shall have replaceable bronze impeller and seal rings on a stainless steel shaft. The pump seal shall be of a mechanical design. Air Compressor The air compressor shall be of the encapsulated screw type, designed and installed to supply a minimum of 50 cfm @ 125 psi (1416 L/min @ 8.6 b) of free air at maximum engine rpm. The compressor air/oil receiver shall be built and designed by the compressor manufacturer. *Manufacturer approved for Flows of 60 cfm @ 150 psi. All air-lines shall be rated to a minimum of 250 psi (17.24 b). All control air fittings shall be of brass of chrome construction. Stainless steel or brass check valves shall be utilized at air injection points to prevent water/solution back-flow into air-lines. Foam Concentrate Proportioner The automatic foam proportioner shall be the Darley Fast Foam 50. It shall be provided and installed to inject foam concentrate into all foam discharges. The proportioner shall automatically meter the correct percentage of foam concentrate, based on current flow, into the water stream. A check valve shall be provided ahead of the foam injection point to prevent foam solution back-flow. The concentrate pump shall be a 12VDC, electrically driven, positive displacement pump. The concentrate pump shall be rated to flow ½ gpm @ 150psi (1.89L/min @ 10.3b). The proportioner on/off switch, ratio controls, operating instructions and low concentrate warning light shall be mounted on the pump panel. Drive System The water pump is directly driven off the engine crankshaft. The air compressor is belt driven off the engine crankshaft and aligned to the crank pulley by attachment to bell housing extension plate. The compressor shall be driven via a dry Gates Power grip® drive system. The complete drive system shall have a 2,000 hour rated service life and shall be designed and rated for the imposed speed and load. Electrical System All electrical equipment installed by the manufacturer shall conform to current automotive electrical system standards and the requirements of the applicable NFPA apparatus standards. The wiring shall be individually and permanently color and function coded. The installation shall meet SAE Standard J1128 in its latest edition for GXL or SXL temperature rating.
i
Specifications are subject to change and improvements without notice. Gates Poly-Chain is a registered trademark of the Gates Corporation, dba The Gates Rubber Company.
®
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
1
Odin® Foam Division, W.S. Darley & Company All exposed wiring shall run in loom with a minimum of 280°F (137.8°C) rating. All wiring loom shall be properly supported and attached to frame members along the entire run. At any point where wire or looms must pass through metal, rubber grommets shall be installed to protect the wire from abrasion. The main low voltage electrical terminal block and circuit breaker panel shall be provided behind the pump operator’s panel in a location providing easy service access. The electrical connections shall be made using heat shrink and/or weatherproof connectors. All electrical circuits shall be protected with automatic reset circuit breakers or fuses. Priming System A Darley air powered jet primer oil-less system shall be utilized. The primer is capable of priming the water pump through 20’ of hard suction hose with an 8’ lift. Primer controls and instruction plate shall be mounted on the operator’s panel. Plumbing, Hoses and Lines All piping shall be stainless steel. Uses of grooved end pipe couplings are required for flexibility and movement of system components on mobile equipment. Hydraulic hoses will only be used for air injection lines and not control air lines. Flexible piping may be used where applicable. Check valves are required throughout the system to maintain integrity and shall be placed so that the air, water foam and foam solution do not inadvertently mix. Drain cocks shall be provided on the water pump to prevent freeze damage. Tank to Pump There shall be a 2.5” tank to pump suction valve fitted in the module and controlled from the operator’s panel. Inlets A 2½” NH male suction inlet with cap and lanyard shall be provided on the operator’s panel. Intake piping is 3” SS plumbing. Water Only Outlet There shall be one 2½” water only discharge with valve operator push pull provided on the control panel. CAF Outlet There shall be a 1½” NH Male CAF outlet on the panel, controlled by the single mix point. A swing check valve shall be installed on the mix point to prevent foam from back flowing into the pump. The CAF mix point controls shall be grouped together on the panel with easy to read calibration marks laser cut into the panel. The mix point foam solution valve shall be an Akron 1 ½” self-locking, swing-out valve. Direct Tank Fill A separate valve with a 2½” NH female swivel connection and plug shall be provided and controlled at the operator’s panel for “direct tank fill” operations with a pressurized water source. Tank Refill A 1½” tank refill line with a 1½” valve and flexible, reinforced wire-braid, hydraulic hose shall be provided. Module Frame The module frame shall be constructed of aluminum and designed for rigorous fire service use. Main structure will use 1.5’ square wall 6061 grade tubing, ¼’ thick wall. The structure will be rectangular in shape to facilitate the full cover lid and sides.
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
2
OdinÂŽ Foam Division, W.S. Darley & Company Lid The lid shall be computer cut, ventilated, diamond plate aluminum with stainless steel hinge and pneumatic gas shock lift struts. The bracing of the lid will sustain the weight of 250 lbs on the module lid when closed. Two snap latches will be incorporated to fasten the lid shut. Corrosion Resistance Treatments Die electric tape (laminating type UHMW) is used through out the construction of the module for dissimilar metal contact surfaces. This will include, but not be limited to control panel to frame, engine mounts to frame, and solution injection unit to frame. All SS screws, which secure the SS panel to the aluminum frame, will be treated with dielectric liquid. The majority of fasteners throughout the module will be SS. All electrical ground connections to the frame will be treated with dielectric silicone compound. Wire ends will have waterproof and corrosion resistant shrink tube, adhesive lined type terminals and connectors. All electrical plugs in the module will be environmentally sealed Deutsch type. The entire surface of the electric fuse / connection box will be treated with a urethane seal coat, to seal out moisture. Control Panel The control panel shall be laser cut, 16 gauge brushed stainless steel with special powder coat infusion on the face. The instruments, indicators and controls that are located on the control panel shall be positioned in a logical manner and clearly marked to provide for simple and easy operation. Color association is used for the handles to specific discharges. The following items shall be mounted on the control panel: 1. Ignition 2. Throttle 3. Fast foam 50 control 4. Primer control 5. CAF valve lever 6. Air valve 7. Operating instructions 8. CAF discharge 9. Water only push pull 10. Water only discharge 11. Primer Vacuum Gauge 12. Water pressure gauge 13. Air pressure gauge 14. Water level gauge 15. Tank to pump Valve 16. Tank refill valve 17. Suction Inlet 18. Direct tank fill push pull 19. Direct tank fill inlet 20. Pump drain 21. Lofa Engine control module a. Hour meter b. Tachometer c. Ignition switch d. Battery charge light e. Glow plug light f. Low oil pressure light g. Engine High Temperature light h. Low water pressure light i. High compressor temperature light
OdinÂŽ Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
3
Odin® Foam Division, W.S. Darley & Company Labels All controls, inlets and discharges shall be clearly labeled. The labels shall comply with applicable NFPA standards. Testing The completed unit shall undergo a manufacturer’s run-in test prior to delivery. The engine, pump and air compressor shall be operated for a minimum period of six (6) hours, during which time the test operator shall monitor and record the functions and performance of each system component. Compressed air foam shall be produced during the test. This testing shall be performed to ensure proper system operation and performance prior to shipment. The manufacturer shall provide written certifications that the tested unit meets all performance criteria contained herein (NFPA). Water flow performance shall be tested in accordance with NFPA 1911. Airflow performance shall be measured with a temperature and pressure compensated air flow meter. Manuals One (1) copy of the Operation and Maintenance Manual and a CD copy shall be provided to the purchaser with each unit. This manual shall include detailed instructions in the operation and maintenance of the overall unit, engine, water pump, air compressor and foam proportioner. Dimensions Length
44” + 6” gap required for air flow
Width
47-3/4”
Height
36”
Weight
1100 lbs
Performance Water Pump Air Compressor
120 gpm @ 100 psi 250 gpm @ 40 psi 50 cfm @ 125 psi
Simultaneous Flow (NFPA)
46 gpm & 23cfm @ 125 psi
Simultaneous Flow
80 gpm & 40cfm @ 100 psi
Engine Horsepower
24.8hp @ 3600 rpm
Warrantyii Engine
1 year
Compressor
1 year
Water Pump
3year/3000 hours
Chemical Injector
1 year
Water Tank
Lifetime
All fabrication and materials are warranted for a period of two (2) years barring accidents, abuse or negligence. Excluding from warranty are all consumables and parts subject to routine replacement. We will repair or assist in the repair or replacement of the product in its entirety.
ii
Covered by the original manufacturer’s warranty.
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
4
Odin® Foam Division, W.S. Darley & Company Mongoose Options The list of options, which follow, can be added to the standard module according to your specifications and needs of operation. These options are not included in the base price of the module. Water Tank The water tank shall be rectangular in configuration and shall have a capacity based on the chassis GVW. The tank shall be constructed of ½” polypropylene sheet. All joints and seams are to be nitrogen welded. The tank cover shall be constructed of ½” polypropylene and shall incorporate hold-downs to assist in keeping the cover rigid under fast filling conditions. The cover shall have a combination vent and manual fill tower. The tower shall have a hinged cover and a ¼” thick polypropylene screen. There shall be two (2) standard tank outlets; one for the tank to pump suction line and one for the tank fill line. An anti-swirl plate shall be installed at the tank-to-pump outlet. A manufacturer’s warranty shall be included for the tank. A polypropylene foam reservoir shall be provided as an integral part of the booster tank and shall contain a low-level sensor in the bottom of the tank to signal when the foam reservoir needs to be filled. The tank shall be plumbed to supply the foam proportioner pump with a minimum ¾” hose (size varies per customer specifications). The tank shall include all fittings, adapters, senders, switches and hoses necessary for tank to module connections. Skid Frame and Water/Foam Tank An aluminum weldment sub-frame shall be provided to support the entire slide-in module, with the base constructed of 2” x 4” x ¼” tubing. The sub frame shall be strong enough to support the weight of the booster tank and pumping equipment while in the apparatus and during loading and unloading and shall be utilized as a base mount for the engine, compressor and pump. Square tubing uprights with angled gussets shall extend up from the rear of the sub frame for attachment of the full width operator’s panel. Provisions shall be incorporated in the sub frame to facilitate using a forklift for loading and unloading of the unit. The tank shall be bolted to the skid frame with stainless steel hardware through full width integral flange mounts at the front and rear. The water tank shall be completely removable without dismounting the skid unit. Remote Start with Throttle Rocker The remote control panel shall be pre-wired with plug-in connectors for ease of installation. The standard wire harness length is twenty-five feet (25’). The remote start option shall include the throttle rocker actuator mounted to the throttle linkage on the engine. The assembly shall include the following components mounted on a placard with the necessary labels permanently painted on the placard. 1) Battery 2) Glow plug 3) Eng Oil psi 4) Eng temp 5) Compressor temp 6) Low water psi. 7) FoamPro Remote On / Off Control (only available w/ FP 2001) OR FRC Tank Vision Mini Water Tank Level Gauge 8) Throttle Rocker Switch 9) Tachometer 10) Hour meter 11) Ignition Switch 12) 97dB Audible Alarm
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
5
Odin® Foam Division, W.S. Darley & Company 1. 5” CAF Discharge with Darley AUTOVALVE Mix Point Controller One (1) 1.5” Compressed Air Foam Mix Point shall be located inside of the module. The 1.5” foam solution valve shall be a 3-piece swing-out valve constructed of brass or stainless steel. The mix point shall be a Darley AUTOVALVEiii. The Darley AUTOVALVE is intended for remote operation. Suggested uses might be Monitor, Front Cannon, or any remote discharge for CAF. The Darley AUTOVALVE control head shall be shipped loose. Discharge Valve The discharge valve shall be a 1½” ball valve mounted on the control panel CAF outlet. Suction Valve A 2.5” gated hydrant type suction valve, with 2.5” male NST threads and cap will be attached to the 2.5” male NST chrome suction intake. Sides The sides shall be computer cut, ventilated, diamond plate aluminum. Economy Hose Reel The hose reel shall be of painted steel construction with fairleads and electric rewind, installed with 100’ of 1” red rubber hose with one 1” plastic ball valve and ¾” tip. The hose reel shall be mounted on top of the water tank and shall have a straight swivel inlet. CAF Hose reel The hose reel shall be of aluminum and alloy construction with fairleads and electric rewind, installed with 100’ of 1” Niedner HotStop hose with one 1” metal pistol grip ball valve and tip. The hose reel shall be mounted on top of the water tank and shall have a straight swivel inlet. Fuel Tank A six-gallon poly fuel tank with a mounting bracket for the fuel tank shall be provided (Shipped loose).
iii
The Darley AUTOVALVE is designed to integrate into a Compressed Air Foam System as a Mix Point control. The function of the AUTOVALVE is to automatically create different Types of Compressed Air Foam, foam solution or compressed air only discharge. The type of foam created by the AUTOVALVE is selected by the apparatus operator.
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
6
Odin® Foam Division, W.S. Darley & Company
Odin® Mongoose “D” 46 /23
Engine Driven C.A.F.S.
Standard Equipment
Engine – Kubota 24.8 hp, water Cooled, 3 cylinder, Diesel Powered, 12 VDC Electric Start Control Panel – Illuminated Laser Cut, Brushed Stainless Steel Panel with infused powder coat painted labels, Foam Injection System Controls Installed Air Compressor – encapsulated screw, Manufacturer approved for Flows of 50 cfm @ 150 psi.
Pump System – Darley Model 2BE with One (1) Fully Adjustable 1½” CAF Discharge Mix Point, 2½” Water Discharge, 2½” Direct Tank Fill, 2½” NPT Suction Inlet, Air jet Primer, 2½” Water and Air Pressure Gauges, Pump Drain Valve, Stainless Steel Plumbing Frame – Lightweight Aluminum Lid – Precision Computer Cut, Ventilated, Hinged, Gas Shock Lift Struts, Latched, Fully Assembled Lid Foam Proportioner System – Darley Fast Foam 50 Class “A” Foam Proportioner
Options 250/15 gallon Water/Foam Poly Tank with Tank Kit, Installed on Full Poly Skid Frame (Larger tanks – Price on Request) 250/15 gallon Water/Foam Poly Tank (Shipped Loose) with Tank Kit – All Fittings, Boots, Clamps, Pipes, and Tank Mount Rubber Necessary to Connect the Module to a Water/Foam Tank (Larger tanks – Price on Request) 1½” Discharge Valve with 1½” NH Chrome Adapter (Necessary for Multiple Discharge Points) Cap – Chrome 1½” NH with Lanyard 2½” Suction valve (Gated hydrant type) Sides – Ventilated, Precision Computer Cut (2 each) Economy Hose Reel - Painted Steel Construction, Installed with 100’ of 1” Red Rubber Hose, 1” Plastic Ball Valve and ¾” Tip. CAF Hose Reel – Aluminum, Installed with 100’ of 1” Niedner Hose, 1” Pistol Grip Ball Valve and Tip Fuel Tank – 6 Gallon Fuel Tank and Mounting Bracket Assembly (shipped loose)
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
7
ON
5.
E R ONL Y
7. AT
H
CO
4.
TE MP
R ES S MP
2.
WATER ONLY DISCHARGE
LY DI SC
8.
W A T E R
FRC
TANK VISION
6.
E-
1/4 -
1/2
3/4 -
F-
W
ODIN FOAM - 1.877.634.6223
%
.
DI SCHA R F.
9.
CON.
LOW
.8 .7 .5 .3 .1 1.0 .9
3. 50
OFF
ON
OFF
10. OPERATING INSTRUCTIONS
NFPA 1906 - 128.2 40 CFM @ 125 PSI
CLOSE AIR VALVE - TURN FOAM SYSTEM OFF FLUSH HOSE WITH WATER REDUCE RPM'S SLOWLY - IDLE 10 SECONDS
SHUTDOWN
THROTTLE PUMP - 90 TO 140 PSI TURN ON FOAM SYSTEM - SET TO .5% OPEN WATER VALVE TO CAF SETTING OPEN AIR VALVE FULLY TO CHANGE FOAM TYPE, ADJUST WATER
ODIN C.A.F.S.OPERATION
START ENGINE - IDLE ONLY PULL PRIMER OUT PUSH HANDLE IN WHEN PRIMED
PRIME PUMP
OPEN TANK TO PUMP VALVE TURN IGNITION SWITCH TO ON WAIT FOR GLOW PLUG LIGHT TO TURN OFF TURN IGNITION SWITCH TO START
STARTING ENGINE
11.
P
US
TO
LTO P R I M
H
UL
S
AR
VAC
30
600 psi
400
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223 N - DR A
20. CTI O
FT
VAC
30
300
600 psi
400
500
EC
T T A NK F
TANK REFILL
TANK TO PUMP
22.
D MP R
0 VAC
30
200
300 400
600 psi
500
N TA
K FI L L -
H
21.
THROTTLE
16.
AIR PRESSURE
100
05.15.11
GE
8
SCALE:
MONGOOSE 'D'PNLLEGEND
MONGOOSE 'D' KUBOTA PANEL LEGEND
TOLEDO, OREGON 97391 - 541.336.5067
SU
0
200
WATER PRESSURE
100
13. 14.
DIRECT TANK FILL
19.
18.
17.
(W H EN EQUIPPED)
Odin Foam
500
PUMP INTAKE
0
300
AIN
DRWN: HAGER
DATE:
C LO
15.
100
200
12.
DI R
1.
NT
THIS DESIGN IS THE PROPERTY OF ODIN FOAM - UNAUTHORIZED REPRODUCTION IS PROHIBITED
1. WATER LEVEL GAUGE 2. COMPRESSOR TEMP LIGHT 3. FAST FOAM 50 CONTROLLER 4. ALARM 5. C.A.F.S. CONTROLER 6. AIR VALVE 7. WATER ONLY DISCHARGE PUSH PULL 8. WATER ONLY DISCHARGE 9. C.A.F. DISCHARGE 10. OPERATING INSTRUCTIONS 11. PRIMER CONTROL 12. PUMP INTAKE GAUGE 13. WATER PRESSURE GAUGE 14. AIR PRESSURE GAUGE 15. LOFA CONTROL BOX 16. THROTTLE 17. TANK TO PUMP VALVE 18. TANK REFILL VALVE 19. DIRECT TANK FILL VALVE 20. SUCTION 21. DIRECT TANK FILL 22. PUMP DRAIN RA
WATE R
YD
C. A
E E
L
PU
OR
IL D I R EC T
CONTROL PANEL
Odin® Foam Division, W.S. Darley & Company PAINTED
P
GE
8.
1. W A T E R
5.
w AD T I E S RC H OA NR L G YE
TEMP
R E SS MP
2. CO
4.
WATER ONLY DISCHARGE
7.
FRC
TANK VISION
6.
E-
1/4 -
1/2
3/4 -
F-
.8 .7 .5 .3 .1
ODIN FOAM - 1.877.634.6223
%
1.0 .9
9.
CON.
LOW
3. 50
D I C S A C F H S A R G E
OFF
ON
OFF
10. OPERATING INSTRUCTIONS
NFPA 1906 - 128.2 40 CFM @ 125 PSI
CLOSE AIR VALVE - TURN FOAM SYSTEM OFF FLUSH HOSE WITH WATER REDUCE RPM'S SLOWLY - IDLE 10 SECONDS
SHUTDOWN
THROTTLE PUMP - 90 TO 140 PSI TURN ON FOAM SYSTEM - SET TO .5% OPEN WATER VALVE TO CAF SETTING OPEN AIR VALVE FULLY TO CHANGE FOAM TYPE, ADJUST WATER
ODIN C.A.F.S.OPERATION
START ENGINE - IDLE ONLY PULL PRIMER OUT PUSH HANDLE IN WHEN PRIMED
PRIME PUMP
OPEN TANK TO PUMP VALVE TURN IGNITION SWITCH TO ON WAIT FOR GLOW PLUG LIGHT TO TURN OFF TURN IGNITION SWITCH TO START
STARTING ENGINE
11.
PR I
M E
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223
9
30
VAC
600 psi
400
(WHEN EQUIPPED)
Odin Foam
SUCTION DRAFT
20.
100
0 VAC
30
300
600 psi
400
500
22.
D MP R
DIRECT TANK FILL
TANK REFILL
TANK TO PUMP
WATER PRESSURE
19.
18.
17.
500
200
13. 0 30
VAC
200
300 400
600 psi
500
16.
DIRECT TANK FILL
21.
THROTTLE
AIR PRESSURE
100
14.
05.15.11
SCALE:
MONGOOSE 'D'PNLLEGEND
MONGOOSE 'D' KUBOTA PANEL LEGEND
TOLEDO, OREGON 97391 - 541.336.5067
DRWN: HAGER
DATE:
TO
L UL
15.
0
300
PUMP INTAKE
100
200
12.
N AI
THIS DESIGN IS THE PROPERTY OF ODIN FOAM - UNAUTHORIZED REPRODUCTION IS PROHIBITED
1. WATER LEVEL GAUGE 2. COMPRESSOR TEMP LIGHT 3. FAST FOAM 50 CONTROLLER 4. ALARM 5. C.A.F.S. CONTROLER 6. AIR VALVE 7. WATER ONLY DISCHARGE PUSH PULL 8. WATER ONLY DISCHARGE 9. C.A.F. DISCHARGE 10. OPERATING INSTRUCTIONS 11. PRIMER CONTROL 12. PUMP INTAKE GAUGE 13. WATER PRESSURE GAUGE 14. AIR PRESSURE GAUGE 15. LOFA CONTROL BOX 16. THROTTLE 17. TANK TO PUMP VALVE 18. TANK REFILL VALVE 19. DIRECT TANK FILL VALVE 20. SUCTION 21. DIRECT TANK FILL 22. PUMP DRAIN
LAZERED OR
PU
CONTROL PANEL
Odin® Foam Division, W.S. Darley & Company
P
DIESEL
AR GE
50
OFF
ON
OFF
10.
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223 10 OPERATING INSTRUCTIONS
NFPA 1906 - 128. 2 40 CFM @ 125 PSI
CLOSE AIR VAL VE - T URN FOAM SYSTEM OFF F LUSH HOSE WITH WAT ER REDUCE RPM'S SL OWL Y - IDLE 10 SECONDS
SHUTDOWN
T HROT TL E PUMP - 90 TO 140 PSI T URN ON F OAM SYST EM - SET T O .5% OPEN WATER VALVE TO CAF SETTING OPEN AIR VALVE FULLY T O CHANGE F OAM TYPE, ADJUST WAT ER
ODIN C.A.F.S.OPERATION
START ENGINE - IDLE ONLY PUL L PRIMER OUT PUSH HANDL E IN WHEN PRIMED
PRIME PUMP
OPEN TANK T O PUMP VAL VE T URN IGNITION SWITCH TO ON WAIT FOR GL OW PLUG LIGHT TO TURN OFF T URN IGNITION SWITCH TO START
STARTING ENGINE
TO
CL
LTO P R I M
H
UL
US
OS
30
300 400
600 psi
C TI O SU
N - DR A
20. FT
30
300 400
600 psi
500
T TA NK F EC
TANK REFILL
TANK TO PUMP
WATER PRESSURE
0
200
MP
DR
22.
0 30
200
300 400
600 psi
500
N TA
K F I LL -
H
21.
THROTTLE
16.
AIR PRESSURE
100
13. 14. 100
DIRECT TANK FILL
19.
18.
17.
Odin Foam
500
PUMP INTAKE
0
200
TOLEDO, OREGON 97391 - 541.336.5067
11.
15.
100
12.
SCALE:
MONGOOSE 'D' KUBOTA NON SKID INSTALLATION ASSEMBLY DATE: 04.21.11 MONGOOSENONSKIDINSTALL DRWN: HAGER
300/20
D I SCHA R F.
9.
ODIN FOAM - 1.877.634.6223
%
.8 .7 .5 .3 .1 1.0 .9
3. CON.
LOW
P P
THIS DESIGN IS THE PROPERTY OF ODIN FOAM - UNAUTHORIZED REPRODUCTION IS PROHIBITED
E R O NL Y
PR E SS
TE M P
M
GE
N AI
THESE DRAWINGS ARE GENERAL SPECIFICATIONS PRIOR TO ENGINEERING PLEASE CONFIRM WITH ODIN FOAM FOR ENGINEERING UPDATES
4.
CO
5.
WATER ONLY DISCHARGE
AT
7.
2.
NT
TANK HEIGHT AND LENGTH VARIES DEPENDENT ON WATER AND CHEMICAL GALLONS
NOTES:
W A T E R
F RC
T ANK VISION
6.
E-
1/4 -
W
LY DISC H ON
8.
F3/4 -
RA YD
WAT E R
. C. A
E E
DI R
1/2
D I R EC T
OR
I
LL
PU
1.
Odin® Foam Division, W.S. Darley & Company
DIESEL
E R ON L Y
PR ES S
O DIN FO AM - 1 .87 7.6 34. 6223
C. A .
D I SCH A R F.
9.
CO N.
%
.8 .7 .5 .3 .1 1.0 .9
3. LOW
GE
GE
50
OFF
ON
OFF
10.
Odin® Mongoose Diesel 46-23 Spec 2014 Odin Foam Div., W.S. Darley www.odinfoam.com 877-634-6223 11 OPERATING INSTRUCTIONS
N FPA 1906 - 128.2 40 CFM @ 125 PSI
11. U TO
O L T PR IM
SH
UL
C LO
S
300 400
600 psi
500
O din F oam
ON- D R A
20. C TI SU FT
300 400
600 psi
500
T TA N K F EC
TANK REFILL
TANK TO PUMP
WATER PRESSURE
0
200
22.
DR MP
0
200
300 400
600 psi
500
N TA
K FI L L -
H
21.
THROTTLE
16.
AIR PRESSURE
100
13. 14. 100
DIRECT TANK FILL
19.
18.
17.
PUMP INTAKE
0
200
TOLEDO, OREGON 97391 - 541.336.5067
CLO SE AIR VAL VE - T URN FO AM SYSTEM OFF F LUSH HOSE WITH WATER REDUCE RPM'S SL O WL Y - IDLE 10 SECONDS
SHUT DOWN
T HROT TL E PUMP - 90 TO 140 PSI T URN ON F OAM SYST EM - SET T O .5% O PEN WATER VALVE TO CAF SETTING O PEN AIR VALVE FULLY T O CHANGE F OAM TYPE, ADJUST WAT ER
ODIN C.A.F.S.OPERAT ION
START ENG INE - IDLE O NLY PUL L PRIMER O UT PUSH HANDL E IN WHENPRIMED
PRIME PUMP
O PEN TANK T O PUMP VAL VE T URN IG NIT IO N SWITCHTO ON WAIT FO R GL OW PLUG LIGHT TO TURNOFF T URN IG NITION SWITCH TO START
START ING ENGINE
15.
100
12.
SCALE:
MONGOOSE 'D' KUBOTA SKID INSTALLATION ASSEMBLY DATE: 04.07.10 MONGOOSESKIDINSTALL DRWN: HAGER
300/20
TE M P
M
P P
THIS DESIGN IS THE PROPERTY OF ODIN FOAM - UNAUTHORIZED REPRODUCTION IS PROHIBITED
4.
CO
5.
WATER ONLY DISCHARGE
AR
N AI
THESE DRAWINGS ARE GENERAL SPECIFICATIONS PRIOR TO ENGINEERING PLEASE CONFIRM WITH ODIN FOAM FOR ENGINEERING UPDATES
2.
NT
TANK HEIGHT AND LENGTH VARIES DEPENDENT ON WATER AND CHEMICAL GALLONS
NOTES:
F RC
W A T E R
7. AT
6.
E-
1/4 -
T ANK VISION
W
LY DI SC H ON
8.
F3/4 -
E
DI R
1/2
E
RA YD
WATE R
L D I R EC T
OR
IL
PU
1.
Odin® Foam Division, W.S. Darley & Company