Vacuum Porcelain Furnace Technical Data: Models: 9495600 CeramFire S 120V 9495601 CeramFire S 230V 9495602 CeramFire S 100V
Performance: Temperature Accuracy: ±3°C from 400 to 1200C (±5.5°F from 750F to 2200°F) Temperature Uniformity: ± 5°C (± 9°F) at steady state.
Weight: Furnace: Shipping:
16kg (35lb) 18kg (40lb)
Safety Information: ETL, CE
Dimensions: Width: Depth: Height Closed: Height Open:
292mm (11.5”) 343mm (13.5”) 348mm (13.7”) 488mm (19.2”)
Electrical Ratings: Volts: 100/120/230V AC, 50/60Hz Watts: 1700W max Watts to Maintain 1000°C (1832˚F): 400W
The CeramFire S Furnace should be used in conjunction with the MaxVac Pump.
Vacuum Porcelain Furnace
Flexible. Simple. Affordable.
DENTSPLY International, Inc., 570 West College Avenue, York, PA 17405-0872, 1-800-243-1942 www.dentsply.com ©2009 DENTSPLY International, Inc. All rights reserved.
PC#9364061 (12/09)
Compact Design Reduced footprint size saves valuable benchtop space.
Vacuum Porcelain Furnace
Feature
Larger Active Heat Zone
Provides temperature uniformity for more consistent firings.
Technology
180 Available user programs
Offers complete flexibility with the ability to enter, customize and save multiple programs.
USB memory loading & backup
Secure method of file transfer and storage.
1200°C (2292°F) Maximum Temp 100°C (212°F) Minimum Temp
Compatible with any porcelain preference.
Smooth muffle movement with stationary work support
Less vibration reduces the chance of damage to the crown or bridge.
Programmable muffle dry position
Allows for pre-dry to remove moisture from the crown or bridge. Muffle slowly lowers to prevent cracking.
Independent low fusing and high fusing temperature calibrations
Furnace will calibrate accurately at both high and low temperatures.
Fast cool down for short times between loads
Maximizes productivity.
Full program flexibility
Ability to change parameters during firing cycle.
Power outage return; Short power outages
Does not interrupt firing cycle or cause loss of vacuum.
Night Mode: Muffle closes when temperature reaches a programmed night temperature
• Prevents moisture absorption • Can be activated during a cycle • Operates independently
Easy temperature and vacuum calibration
Provides operator ability to read and adjust calibrations from the control panel.
Skip Feature
Allows operator to fast forward through the current program to the next function.
Quartz spiral muffle
Ensures homogeneous distribution of heat inside the firing chamber.
Purge Cycles: Vacuum purge for muffle decontamination after the use of silver alloys. Air Purge for Other Alloys.
Cleans muffle.
The DENTSPLY Utility Program allows the user to easily customize firing parameters, edit/delete saved programs, enter new programs, and print customized firing charts; all from the convenience of your PC and easily transferred to the furnace via the USB stick included.
Benefit to Lab
3-Year or 15,000 cycle Warranty (whichever occurs first).
Now Available with a
Digital Single-Setpoint Controller
Vulcan ulcan®3-550 PD (Power Door) Furnace For Hands-Free Operation
Vulcan Benchtop Furnaces ®
Featuring High Performance Hybrid Muffle Technology - Exclusive to Ceramco®'s Neytech brand of furnaces Vulcan® benchtop furnaces are available in three standard muffle sizes and each can be purchased with one of three different controllers. Single setpoint analog controllers are an economical option when rate of temperature climb is not a concern. Single setpoint digital controllers allow the operator to control the rate of temperature climb, and monitor the progress of the program on an easy-to-read, accurate digital display. Three-stage digital programmable models have nine multi-stage programs, a hold temperature program, and a delay start option which allows a program's start time to be delayed for up to seven days. Each Vulcan is constructed with a heavy gauge steel cabinet finished with durable baked enamel coating. A vertical lift door is standard for operator safety and space conservation.
Ceramco®’s Neytech benchtop furnaces feature: • Control option: single point analog, digital or three-stage digital programmable • High performance hybrid muffle design for faster heating and cooling than full firebrick • Safety designed, vertical lift door saves space and directs heat away from the operator • Venturi air exchange (selected models) • Power door (selected models) • 2-year limited warranty
570 West College Avenue, York, PA 17405-0872 Domestic Customer Service: 717-699-4190 International Customer Service Fax: 609-239-0204 www.ceramco.com REF 800357 Rev. 07/06
3-550 A Our New 3-1750A Air Single Exchange Furnace Setpoint Pre-heated air is Digital drawn through the Controller heating chamber Adjust the rate using an exclusive of temperature air venturi exhaust climb to match design. The result is that combustion gases are the requirements of different investments with more rapidly exhausted, increasing combustion this easy-to-program option. uniformity and furnace life. The furnace is designed to meet ASTM D3174 specifications. Above is the rear view of a NeyTech Vulcan furnace with a venturi exhaust system.
Ten Specialty Models The prefix refers to the Controller – ”A” for Analog, Single Set Point; “D” for Single Set Point Digital Control; “3” for Digital, 3 Stage Programmable Control. The numeral refers to the Chamber size in cubic inches-130, 550 and 1750. (For exterior and muffle dimensions see lower left column.) The suffix refers to – “A” for Air Venturi, “PD” for Power Door. *Vulcan benchtop furnaces have a maximum temperature of 1100°C (2012°F).
3-550PD has a Power Door for Hands-Free Operation You can now concentrate on the task of material handling using both hands. The remote switch closure on the Ney Vulcan 3-550PD sets the standard for safety and convenience.
Marking
Watts
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
720 1060
9495120 9495121
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
720 1060
3-130
9493302 9493303
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
720 1060
A-550
9493306 9493307
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
1440 2400
D-550
9495130 9495131
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
1440 2400
3-550
9493308 9493909
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
1440 2400
3-550A
9493985
230V - 50/60Hz
ETL & CE
2200
3-550PD
9493826 9493827
120V - 50/60Hz 200-240V - 50/60Hz
ETL CE
1440 2400
A-1750
9493407 9493657 (Euro)
200-240V - 50/60Hz 230V - 50/60Hz
ETL CE
4800 4370
D-1750
9495140 9495141 (Euro)
200-240V - 50/60Hz 230V - 50/60Hz
ETL CE
4800 4370
3-1750
9493409 9493658 (Euro)
200-240V - 50/60Hz 230V - 50/60Hz
ETL CE
4800 4370
3-1750A
9493990
230V - 50/60Hz
ETL & CE
4370
Model
Number
Voltage
A-130
9493300 9493301
D-130
Exterior Dimensions Model 130 550 3-550A 1750 3-1750A
A 510mm (20.0”) 630mm (25.0”) 630mm (25.0”) 815mm (32.0”) 815mm (32.0”)
350mm 410mm 430mm 545mm 541mm
B (13.8”) (16.0”) (17.0”)* (21.5”) (21.3”)
140mm 230mm 230mm 360mm 360mm
F (5.7”) (9.0”) (9.0”)* (14.0”) (14.0”)
C 290mm (11.5”) 400mm (15.8”) 400mm (15.8”) 610mm (24.0”) 610mm (24.0”)
D 330mm (13.0”) 430mm (17.0”) 489mm (19.3”)* 535mm (21.0”) 584mm (23.0”)*
Internal Muffle Dimensions Model 130 550 3-550A 1750 3-1750A
E 120mm (4.6”) 180mm (7.0”) 180mm (7.0”) 250mm (10.0”) 250mm (10.0”)
Model 130 550 3-550A 1750 3-1750A
Furnace Weight 11 kg (25 lbs.) 20 kg (45 lbs.) 23 kg (51 lbs.) 45 kg (100 lbs.) 55 kg (120 lbs.)
Shipping Weight 16 kg (35 lbs.) 27 kg (60 lbs.) 28 kg (62 lbs.) 61 kg (135 lbs.) 67 kg (148 lbs.)
G 130mm (5.2”) 230mm (9.0”) 230mm (9.0”) 320mm (12.5”) 320mm (12.5”)
* Dimension includes exhaust tube not shown