dr._mach_dental_solutions_english

Page 1

Flossmannstr. 28 · D-85560 Ebersberg Phone: +49 (0) 8092 / 20 93-0 · Fax: +49 (0) 8092 / 20 93-50 www.dr-mach.com · e-mail: info@dr-mach.de

Light systems for dental medicine and oral surgery

Mach M3 Mach M3 with instrument tray Mach M3 with video system Mach M2 Mach 130 Mach lights for KaVo Centro column

Subject to change without notice due to technical modification · 59000252 A01 · Version: 03/2007

Dental Solutions Dr. Mach GmbH & Co. KG

Dental Solutions

O p e r a t i n g

a n d

e x a m i n a t i o n

l i g h t s


Focus on the light!

Dr. Mach sets standards

Introduction

. . . . . . . . . . . . . . . . . . . . . . . . . .

2–3

Advantages

. . . . . . . . . . . . . . . . . . . . . . . . . . .

4–5

in the medical illumination technology since decades.

Dr. Mach operating and examination lights support your professionality by innovative techology and design. Natural colour reproduction and exact illumination of the oral cavity with the Duo-Focus-Technology make

Operating ligths Mach M3 ceiling-, walland mobile lights . . . . . . . . . . . . . . . . . . . . . . . 6 – 7 Mach M3 with instrument tray . . . . . . . . . 8 Mach M3 with video system

. . . . . . . . . . .

9

your work easier and convey safety and trust to your patient.

Your

Team

Small operating lights Mach M2 ceiling-, walland mobile lights . . . . . . . . . . . . . . . . . . . 10 – 11

Examination lights Mach 130 ceiling-, walland mobile lights . . . . . . . . . . . . . . . . . . . 12 – 13

Mach lampheads mounted to KaVo Centro column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 – 15

2

C o n t e n t s

3


Advantages

R9-values between 20 and 70

Ra-values between 50 and 95 Conventional lighting systems

R9 ≥ 90

Ra = 96

Light quality and optics

Additional comfort

Superior colour rendition With a previously unattainable colour rendition Ra = 96 and

Multi-facetted reflector system (only for Mach M3 and Mach M2)

R9(red) ≥ 90 you easily see the tiniest nuances of colour in tissue.

Over 3000 facettes per reflector guarantee a homogenous light field

For recognizing the exact colour spectrum of the wound the exact

and avoid disturbances through shadows in the light field.

rendition of the red colour range is essential. R9(rot) ≥ 90 means for the surgeon a visibly better recognition of details. The colour spectrum of the wound is rendered naturally. The OT-light clearly provides welcome

Dr. Mach light system R96

relief for your eyes.

Cool light Coated cold light reflectors reduce in connection with dielectrically coated cold light filters the heat radiation to a minimum. The

Multi-reflector system (only for Mach M3) Reflectors arranged in circular position increase as

unwanted infrared radiation of the light source is not reflected by the reflectors but released to the upper side (ceiling). The heat increase under the lamphead is avoided. The surgeons head area remains cool.

multiple-reflector system the contrast of the light.

Flow properties Duo-Focus-Technology: Merging of the individual luminous fields (only for Mach M3) By turning of the sterilizable handle the reflectors swivel.

The form of the housing shows excellent flow properties and produces optimum conditions for laminar flow systems.

The three light fields are joined and overlap to one field with

Easy maintenance

increased light intensity.

Without tools and with only a few steps the lamp housings can be opened to have access to all system components. Due to the module technology all components can be easily exchanged. Within 30 seconds you exchange the bulb. The housings are easy to clean.

Mach M3 operating light

Focussing (optional) By turning of the adjustment ring at the sterilizable handle the bulbs are moved inside the reflector up and down. The focussable light beam allows a punctual illumination of deepest wound channels with hight intensity and an exact matching of the light field diameter with the size of the wound field.

Mach M3 operating light

4

A d v a n t a g e s

A d v a n t a g e s

5


Mach M3 operating light

Mach M3 operating light

Mach M3 with ceiling fixation

Mach M3 with ceiling fixation and central spring arm

Ceiling fixation with central spring arm

Mach M3 with cardanic suspension and wall fixation

Performance description Mach M3 F

Mach M3 mobile with four castors

Handling

Ceiling fixation

3 functions via touch panel:

Merging of light fields

• on/off • focussing • light intensity control

Superior colour rendition Multi-facetted reflector system

Technical data Mach M3 light system(1)

Cool light

Mach M3 DF(2)

Mach M3 F(3)

130.000

100.000

Colour rendering index Ra(4) at 4300 Kelvin

96

96

Colour rendering index R9(5) at 4300 Kelvin

≥ 90

≥ 90

12 - 30

17 - 28

4300

4300

Electronic light intensity control at the lamphead

surcharge

surcharge

Photometric radiation equivalent

280 lm/W

280 lm/W

2° C

2° C

150 W

150 W

Light intensity Lux in 1 meter distance

Optimum flow properties Wall fixation

Easy maintenance Housing of die-casted aluminium

Focussable size of the light field (in cm)

The material guarantees sturdyness and long life. The heat leaves the housing at the upper side while the head area remains cool.

Colour temperature (Kelvin)

Mach M3 DF Focussing • punctual illumination of deepest wound channels • exact adjustment of the light field to the size of the wound area

for room height

Additionally to the advantages of the F-model:

Temperature increase in head area Total power consumption Light source Halogen 22,8V / 50W

Mobile light with four castors

Options against surcharge

3

3

Working distance (in cm)

60 - 150

70 - 140

Height adjustment (in cm)

118

118

(1)

external transformer DF-models with Duo-Focus system: merging of light fields and focussing (3) F-models with merging of light fields (4) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100. (5) R9 is the value for the rendering of the colour red. This is not used in calculating the general colour rendering index Ra . The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area. (2)

Focussable DF-model

The light beams of the three reflectors can be merged by the sterilizable handle and –

Electronic light intensity control with on/off-switch

optionally – also focussed.

Dimensions in millimeter

Mechanical on/off-switch at the lamphead

6

O p e r a t i n g

l i g h t s

O p e r a t i n g

l i g h t s

7


Mach M3 operating light

Mach M3 with ceiling fixation

Mach M3 with ceiling fixation and central spring arm

Mach M3 with cardanic suspension and wall fixation

Mach M3 mobile with four castors

Performance description

Handling

Mach M3 F

3 functions via touch panel:

Merging of light fields

• on/off • focussing • light intensity control

Superior colour rendition Multi-facetted reflector system

Technical data Mach M3 light system(1)

Mach M3 DF(2)

Mach M3 F(3)

130.000

100.000

Colour rendering index Ra(4) at 4300 Kelvin

96

96

Colour rendering index R9(5) at 4300 Kelvin

≥ 90

≥ 90

12 - 30

17 - 28

4300

4300

Electronic light intensity control at the lamphead

surcharge

surcharge

Additionally to the advantages of the F-model:

Photometric radiation equivalent

280 lm/W

280 lm/W

Focussing

Temperature increase in head area

2° C

2° C

• punctual illumination of deepest wound channels • exact adjustment of the light field to the size of the wound area

Total power consumption

150 W

150 W

Cool light

Light intensity Lux in 1 meter distance

Optimum flow properties Easy maintenance Housing of die-casted aluminium

Focussable size of the light field (in cm)

The material guarantees sturdyness and long life. The heat leaves the housing at the upper side while the head area remains cool.

Colour temperature (Kelvin)

Mach M3 DF

Light source Halogen 22,8V / 50W

Options against surcharge

3

3

Working distance (in cm)

60 - 150

70 - 140

Height adjustment (in cm)

118

118

(1)

external transformer DF-models with Duo-Focus system: merging of light fields and focussing (3) F-models with merging of light fields (4) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100. (5) R9 is the value for the rendering of the colour red. This is not used in calculating the general colour rendering index Ra . The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area. (2)

Focussable DF-model

The light beams of the three reflectors can be merged by the sterilizable handle and –

Electronic light intensity control with on/off-switch

optionally – also focussed.

Mechanical on/off-switch at the lamphead

6

O p e r a t i n g

l i g h t s

O p e r a t i n g

l i g h t s

7


Available plugs (price on request) * 1-fold electric plug (green) ** 2-fold electric plug (green) for mains supply (with emergency power supply) for *4300 0006 and **4300 0003; **4300 0007

* 1-fold electric plug (red) Free turning and swivelling

Integrated video system

** 2-fold electric plug (red) for central power supply (with emergency power supply)

for *4300 0006 and **4300 0003; **4300 0007

The video- and control signals are not transmitted conventionally by separate cables – but via the electric lines and * sliding contacts of the 1-fold electric plugoperating (green) light.

** 2-fold electric plug (green) for mains supply

Advantages: (without emergency power supply) with illumination The operating light permits continuous rotary movement. for *4300 0006 and **4300 0003; **4300 0007 The upgrading of the camera is significantly cheaper and easier. The camera doesn´t need readjustment dependig on the distance between lamphead and wound area as it is positioned centrally in the lamphead.

8

360°

8

360°

8

Continuous rotation

NEW

Objectiv systems

By a new digital camera remote control can electric now receive * you 1-fold plug digital (red) video signals for the computer or network. ** Analog camera images converted 2-fold electric plugare (red) for central power supply (with emergency power supply) in MPEG4-video signals. These are available through a RJ45 interface at with the illumination remote control and a network cable. for *4300 0006 and **4300 0003; **4300 0007

* 1-fold plug (white) Available digital video systems

4300 4300 4300 4300

0003: 379 0006: 379 0007: 379 0009: 379

x x x x

479 479 479 479

mm, mm, mm, mm,

Video system DIGITAL ECO

2 electric plugs 1 electric plug 4 electric plugs without electric

* special sizes upon request

Everything under control:

** 2-fold plug (white) for potential exchange connection

for *4300 0006 and **4300 **4300 0007 Every computer in the netwotk has access to the video images0003; and they can be saved on a hard disc drive of sufficient capacity. Variations with potential exchange plug or different power circuits upon request Video system DIGITAL PC-CONTROL

As with the video system Digital Eco every computer in the network has withdisc instrument access to the video images and they can beCeiling savedfixation on a hard drive oftray sufficient capacity. Additionally the camera can be controlled by a specially designed software through the PC-screen. This is done by an IP-address designated for the camera remote control.

• max. load capacity 14 kg (please state the exact load when placing orders) • equipped with 1, 2 or 4 electric plugs • also available without electric

Internet

Beamer in the auditorium 1 Beamer in the auditorium 2

Router

PC 3 PC 2 PC 1

Operating light with digital video system in the operation-theatre

MFB-MO(1)

72-fold zoom f = 4.1 to 73.8 mm F1.4-3.0 Auto Focus (integr. focussing system)

OFB-ST(2)

72-fold zoom Auto Focus (integr. focussing system)

Video exit 75 Ohm

Y: VS1.0 Vp-p. Sync. Negative C: Burst 0.300 Vp-p VBS: 1.0 Vp-p Composite

Y: VS1.0 Vp-p. Sync. Negative C: Burst 0.300 Vp-p VBS: 1.0 Vp-p Composite

Image points

752 (H) x 582 (V)

752 (H) x 582 (V)

Horizontal resolution

Over 460 lines

Over 460 lines

Vertical resolution

Over 400 lines

Over 400 lines

Humidity

20 - 85%

20 - 85%

Dimensions (Ø, Length)

80 x 150 mm

80 x 150 mm

Weight

900 g

900 g

Interference radiation in acc.with

FCC class A

FCC class A

(1) (2)

with remote control, with image rotation without remote control, without image rotation

an ergonomic combination

No additional cables are needed for the camera. By a special electronic design the power supply of the operating light is used for the transmission of the control- and video signals.

for relaxed working

For detailed informations please ask for our special catalogue for single lights.

Dimensions in Millimeter

8

Local intranet (LAN)

Colour image camera for visual communication (PAL / NTSC)

Instrument tray Item number:

• 72-fold zoom • focus-control (automatic/manual) • iris-control (automatic/manual) • colour-control • frozen image • optional with image rotation

Dr. Mach camera

Advantages: You don´t need a video card any longer. The images can be directly saved on the computer if sufficient capacity is available. Nevertheless you can further record the signals on video or DVD-recorders. For this the remote control panel is equipped with two S-video (Y/C) connectors.

360°

Camera remote control

Technical data

A Sony camera with 72-fold zoom, autofocus, autoiris and image rotation is used. Via remote control panel it can be controlled at the same time from an auditorium or other rooms.

Digital video system

Mach M3 with video system

Mach M3 operating light with instrument tray

… with instrument tray

Integrated video system

Electric plug system

W i t h

i n s t r u m e n t

t r a y

W i t h

i n t e g r a t e d

v i d e o

s y s t e m

9


Mach M3 with video system

Integrated video system Mach M3 operating light with instrument tray Free turning and swivelling Integrated video system The video- and control signals are not transmitted conventionally by separate cables – but via the electric lines and sliding contacts of the operating light. Advantages: The operating light permits continuous rotary movement. The upgrading of the camera is significantly cheaper and easier. The camera doesn´t need readjustment dependig on the distance between lamphead and wound area as it is positioned centrally in the lamphead.

8

360°

8

360°

8

Continuous rotation

4300 4300 4300 4300

0003: 0006: 0007: 0009:

379 379 379 379

NEW

Objectiv systems

By a new digital camera remote control you can now receive digital video signals for the computer or network. Analog camera images are converted in MPEG4-video signals. These are available through a RJ45 interface at the remote control and a network cable.

479 479 479 479

mm, mm, mm, mm,

Video system DIGITAL ECO

2 electric plugs 1 electric plug 4 electric plugs without electric

Every computer in the netwotk has access to the video images and they can be saved on a hard disc drive of sufficient capacity.

Video system DIGITAL PC-CONTROL

* special sizes upon request

Everything under control:

8

As with the video system Digital Eco every computer in the network has access to the video images and they can be saved on a hard disc drive of sufficient capacity. Additionally the camera can be controlled by a specially designed software through the PC-screen. This is done by an IP-address designated for the camera remote control.

• max. load capacity 14 kg (please state the exact load when placing orders) • equipped with 1, 2 or 4 electric plugs • also available without electric

Router

PC 3 PC 2 PC 1

Operating light with digital video system in the operation-theatre

MFB-MO(1)

72-fold zoom f = 4.1 to 73.8 mm F1.4-3.0 Auto Focus (integr. focussing system)

Available digital video systems x x x x

Internet

Beamer in the auditorium 1 Beamer in the auditorium 2

OFB-ST(2)

Colour image camera for visual communication (PAL / NTSC)

Instrument tray Item number:

Local intranet (LAN)

Dr. Mach camera

Advantages: You don´t need a video card any longer. The images can be directly saved on the computer if sufficient capacity is available. Nevertheless you can further record the signals on video or DVD-recorders. For this the remote control panel is equipped with two S-video (Y/C) connectors.

360°

• 72-fold zoom • focus-control (automatic/manual) • iris-control (automatic/manual) • colour-control • frozen image • optional with image rotation

Technical data

A Sony camera with 72-fold zoom, autofocus, autoiris and image rotation is used. Via remote control panel it can be controlled at the same time from an auditorium or other rooms.

Digital video system

Camera remote control

72-fold zoom Auto Focus (integr. focussing system)

Video exit 75 Ohm

Y: VS1.0 Vp-p. Sync. Negative C: Burst 0.300 Vp-p VBS: 1.0 Vp-p Composite

Y: VS1.0 Vp-p. Sync. Negative C: Burst 0.300 Vp-p VBS: 1.0 Vp-p Composite

Image points

752 (H) x 582 (V)

752 (H) x 582 (V)

Horizontal resolution

Over 460 lines

Over 460 lines

Vertical resolution

Over 400 lines

Over 400 lines

Humidity

20 - 85%

20 - 85%

Dimensions (Ø, Length)

80 x 150 mm

80 x 150 mm

Weight

900 g

900 g

Interference radiation in acc.with

FCC class A

FCC class A

(1) (2)

with remote control, with image rotation without remote control, without image rotation

an ergonomic combination

No additional cables are needed for the camera. By a special electronic design the power supply of the operating light is used for the transmission of the control- and video signals.

for relaxed working

For detailed informations please ask for our special catalogue for single lights.

W i t h

i n s t r u m e n t

t r a y

W i t h

i n t e g r a t e d

v i d e o

s y s t e m

9


Mach M2 with cardanic bow, ceiling fixation

Mach M2 with ceiling fixation and central spring arm

Mach M2 small operating light

Mach M2 small operating light

Ceiling fixation with central spring arm

Mach M2 with wall fixation

Performance description Mach M2

Mach M2 mobile with four castors (optionally with emergency power supply)

Ceiling fixation

Superior colour rendition Multi-facetted reflector system Cool light

Technical Data Mach M2 light system(1)

Optimum flow properties

Mach M2(3)

90.000

60.000

Colour rendering index Ra(4) at 4300 Kelvin

96

96

Colour rendering index R9(5) at 4300 Kelvin

≥ 90

≥ 90

14 - 28

18 (fixed focus)

4300

4300

Electronic light intensity control at the lamphead

surcharge

surcharge

Photometric radiation equivalent

280 lm/W

280 lm/W

Temperature increase in the head area

2° C

2° C

Total power consumption

80 W

80 W

1

1

Emergency light source Halogen IRC 22V / 80W

surcharge

surcharge

Working distance (in cm)

70 - 140

70 - 140

Height adjustment (in cm)

118

118

Light intensity in Lux at 1 meter distance

Easy maintenance Wall fixation

Mach M2 F

Mach M2 F(2)

Additionally to the advantages of the Mach M2:

Focussing

Focussable light field size (in cm) Colour temperature (Kelvin)

Electronic light intensity control

for room height

Options against surcharge The stepless adjustment between 50% and 100% is done through a touch panel at the lamp bow. A LED-display at the touch panel shows the actual setting of the intensity. Mobile light with four castors

Handy small operating light

Light source Halogen IRC 22V / 80W

(1)

external transformer F-models with focussing models with fixed focus (4) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100. (5) R9 is the value for the rendering of the colour red. This is not used in calculating the general colour rendering index Ra . The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area.

Emergency halogen bulb

with the optional advantage

(2) (3)

If the halogen bulb fails during operation the emergeny bulb automatically swivels in the position and continues. Dimensions in millimeter

of focussing

10

O p e r a t i n g

l i g h t s

O p e r a t i n g

l i g h t s

11


Mach M2 small operating light

Mach M2 with cardanic bow, ceiling fixation

Mach M2 with ceiling fixation and central spring arm

Mach M2 with wall fixation

Mach M2 mobile with four castors (optionally with emergency power supply)

Performance description Mach M2 Superior colour rendition Multi-facetted reflector system Cool light Technical Data Mach M2 light system(1)

Optimum flow properties

Mach M2 F(2)

Mach M2(3)

90.000

60.000

Colour rendering index Ra(4) at 4300 Kelvin

96

96

Colour rendering index R9(5) at 4300 Kelvin

≥ 90

≥ 90

14 - 28

18 (fixed focus)

4300

4300

Electronic light intensity control at the lamphead

surcharge

surcharge

Photometric radiation equivalent

280 lm/W

280 lm/W

Temperature increase in the head area

2° C

2° C

Total power consumption

80 W

80 W

1

1

Emergency light source Halogen IRC 22V / 80W

surcharge

surcharge

Working distance (in cm)

70 - 140

70 - 140

Height adjustment (in cm)

118

118

Light intensity in Lux at 1 meter distance

Easy maintenance

Mach M2 F Additionally to the advantages of the Mach M2:

Focussing

Focussable light field size (in cm) Colour temperature (Kelvin)

Options against surcharge Electronic light intensity control The stepless adjustment between 50% and 100% is done through a touch panel at the lamp bow. A LED-display at the touch panel shows the actual setting of the intensity.

Handy small operating light

(1)

external transformer F-models with focussing models with fixed focus (4) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100. (5) R9 is the value for the rendering of the colour red. This is not used in calculating the general colour rendering index Ra . The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area.

Emergency halogen bulb

with the optional advantage

(2) (3)

If the halogen bulb fails during operation the emergeny bulb automatically swivels in the position and continues.

of focussing

10

Light source Halogen IRC 22V / 80W

O p e r a t i n g

l i g h t s

O p e r a t i n g

l i g h t s

11


Mach 130 with ceiling fixation

Mach 130 with wall fixation

Mach 130 examination light

Mach 130 examination light

Mach 130 mobile with four castors

Mach 130 mobile with four castors and emergeny power supply

Performance description Mach 130

Ceiling fixation

Superior colour rendition Exact positioning of the light by the handle and a lateral grip bar Electronic stepless light intensity control by the lampheads’ on/off-switch (turntable potentiometer)

Technical data

Wall fixation On/off-switch + light intensity control

35.000

Colour rendering index Ra(3) at 4300 Kelvin

96

93

Colour rendering index R9(4) at 4300 Kelvin

≥ 90

≥ 80

14 - 25

17 (fixed focus)

4300

4300

standard

standard

50 W

50 W

1

1

230 V / 50 Hz

230 V / 50 Hz

70 - 140

70 - 140

Light field diameter (in cm)

22

22

Height adjustment (in cm)

119

119

mat silk RAL 9010

mat silk RAL 9010

Colour temperatur (Kelvin)

Available also with separate transformer but then without light intensity control

Electronic light intensity control at the lamphead

distance to the lower fixation drilling

min. room height

50.000

Focussable light field size (in cm)

Electronic transformer in the lamphead

Total power consumption

Additionally to the advantages of the Mach 130:

Focussing of the light field by turning of the handle

Mach 130(2)

Light intensity in Lux at 1 meter distance

On/off-switch at the lamphead

Mach 130 F

Mach 130 F(1)

Mach 130 light system

Light source Halogen 22,8V / 50W Mains connection Working distance (in cm)

Cool light

Mobile light with four castors

Coating

Option against surcharge

(1)

F-models with focussing models with fixed focus (3) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100. (4) R9 is the value for the rendering of the colour red. This is not used in calculating the general colour rendering index Ra . The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area. (2)

Compact examination light with the light quality of an operating light for diagnosys and prophylaxis

12

Sterilizable handle

E x a m i n a t i o n

l i g h t s

E x a m i n a t i o n

l i g h t s

Dimensions in millimeter

Sterilizable handle

13


Mach 130 examination light

Mach 130 with ceiling fixation

Mach 130 with wall fixation

Mach 130 mobile with four castors

Mach 130 mobile with four castors and emergeny power supply

Performance description Mach 130 Superior colour rendition Exact positioning of the light by the handle and a lateral grip bar Electronic stepless light intensity control by the lampheads’ on/off-switch (turntable potentiometer) On/off-switch at the lamphead

Technical data Mach 130 F(1)

Mach 130(2)

50.000

35.000

Colour rendering index Ra(3) at 4300 Kelvin

96

93

Colour rendering index R9(4) at 4300 Kelvin

≥ 90

≥ 80

14 - 25

17 (fixed focus)

4300

4300

standard

standard

50 W

50 W

1

1

230 V / 50 Hz

230 V / 50 Hz

70 - 140

70 - 140

Light field diameter (in cm)

22

22

Height adjustment (in cm)

119

119

mat silk RAL 9010

mat silk RAL 9010

Mach 130 light system Light intensity in Lux at 1 meter distance

On/off-switch + light intensity control

Focussable light field size (in cm)

Electronic transformer in the lamphead

Colour temperatur (Kelvin)

Available also with separate transformer but then without light intensity control

Electronic light intensity control at the lamphead

Mach 130 F

Total power consumption

Additionally to the advantages of the Mach 130:

Light source Halogen 22,8V / 50W

Focussing of the light field by turning of the handle

Mains connection Working distance (in cm)

Cool light

Coating

Option against surcharge

(1)

F-models with focussing models with fixed focus (3) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100. (4) R9 is the value for the rendering of the colour red. This is not used in calculating the general colour rendering index Ra . The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area. (2)

Sterilizable handle

Compact examination light with the light quality of an operating light for diagnosys and prophylaxis

12

Sterilizable handle

E x a m i n a t i o n

l i g h t s

E x a m i n a t i o n

l i g h t s

13


Mach operating lights – perfect integration at the KaVo Centro column Working with system

The Mach M3 can also be integrated

Perfect integration Dr. Mach operating and examination lights can be perfectly combined with KaVo Centro, your dental and oral examination and operating unit. Your KaVo Centro column can be loaded with a lot. With multiple horizontal arms for the fixation of instruments, with multiple continuous installation channels and easy installation access and with the safety of a stable two-point-fixation at floor and ceiling. So everything is safe and perfect within reach: monitor, microscope, x-ray unit, instrument tray, operating or examination light. All worksteps are involved in a harmonic process. This allows a calm and relaxed working process that will also convince your patients.

Dr. Mach lights at KaVo Centro: the convenient combination for your practice

With KaVo Centro you have individual configuration and extension options for future technologies independent from product lifetimes of single components. The technical status this way can be continuosly kept on the newest level. The changing or upgrading can be done fully clean at undisturbed practice operation.

14

K a V o

C e n t r o

C o l u m n

K a V o

C e n t r o

C o l u m n

15


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.