ECPEN13-004 Residential catalogue

Page 1

Designed

colder climates for

Residential catalogue Spli t system Optimal climate control


Designed for living:

solutions for even the coldest regions

For most people, total climate control in the home means having the ability to select a desirable temperature for each room and to have that temperature maintained no matter what the temperature outside – even when it is down to -25ºC – and to do this cost-effectively and energy-efficiently, without drafts, noise, and by blending in within any interior décor. In a domestic setting, this means heating, cooling and high air quality is needed for year round comfort. At Daikin we know that the best way to achieve energy efficiency is to install a heat pump, which draws up to 75% of the output heat from renewable energy (outside air). Especially for the coldest regions, the outdoor units of this heat pump have been redesigned to withstand extreme weather conditions with excellent energy efficiency ratings. Our indoor units have won prestigious design awards for their almost iconic designs that will fit into any décor. We have also designed the indoor units to operate in a whisper-quiet mode and to distribute purified air in a way that does not produce unpleasant air currents. Truly, climate control by design.

2


 Optimised heating solutions down to -25°C outdoor temperatures  Blends unobtrusively with any interior décor  Prevents winter freezing in summer homes  Whisper quiet  Energy efficient

3


Main features Especially designed for colder climates

Optimised heating solutions down to -25°C outdoor temperatures.

Blends

unobtrusively with any interior décor Our floor standing and wall mounted units have been designed to provide

functionality combined with award winning attractive modern lines that blend into the décor of any room.

Wide range available Daikin can offer the optimised solution for every household thanks to the wide range of units available from 2.5 to 8.1 kW heating capacity.

Preventing winter freezing in your summer home

It is possible to set the system to switch on when interior temperatures drop below 10ºC, thus avoiding frozen pipes, and so provide winter protection for unoccupied summer homes, garages and basements. By maintaining this temperature, the system reduces the cost of overwinter heating. 4


Award-winning design Our Daikin Emura range was awarded with several prestigious design awards: iF Product Design award 2010, Reddot design award honourable mention 2010, Good Design and Designpreis Deutschland 2011 Nominee. Daikin Emura was evaluated on a range of criteria including design quality, workmanship and choice of materials, degree of innovation, environmental friendliness, functionality, ergonomics and safety.

5


Innovation in action Europe’s new energy label: raising the bar on energy efficiency To realise its challenging 20-20-20 environmental goals, Europe is imposing minimum efficiency requirements for energy related projects. These minimum requirements for air conditioners below 12 kW come into effect on 1 January 2013, and will be revised upward in 2014. Not only does the Eco-Design Directive systematically raise the minimum requirements with respect to energy performance, the method used to measure this performance has also been changed to better reflect real-life conditions. The new seasonal performance rating provides a much more accurate picture of real-life energy efficiency over an entire heating or cooling season because it takes various temperatures and load conditions into account.

20 30 10

90 100 80

50 60 70 40

capacity

Temperature Nominal 1 Temperature condition: 35°C for cooling 7°C for heating Does not often occur in reality

Seasonal Several rating temperatures for cooling and heating, reflecting actual performance over an entire season

Auxiliary modes

Capacity Nominal Does not reflect partial capacity Benefits of inverter technology not visible

Seasonal Integrates operation at partial instead of full capacity

Nominal Does not take auxiliary power modes into account

Benefits of inverter technology are shown

Seasonal Includes consumption auxiliary modes: • Thermostat off • Standby mode • OFF mode • Crankcase heater

Nominal efficiency gives an indication on how efficient an air conditioner is when operating in a nominal condition. Seasonal efficiency gives an indication on how efficient an air conditioner is when operating over an entire cooling or heating season.

High seasonal energy efficiency: Up to A++ The Daikin heat pumps designed for colder climates have excellent seasonal efficiency ratings.

SCOP & SEER up to A++

Inverter technology Daikin’s inverter technology is a true innovation in the field of climate control. The principle is simple: inverters adjust the power used to suit the actual requirement - no more, no less! This technology provides you with two concrete benefits:

Comfort The inverter repays its investment many times over by improving comfort. An air conditioning system with an inverter continuously

adjusts its cooling and heating output to suit the temperature in the room, thus improving comfort levels.

The inverter reduces system start-up time enabling the required room temperature to be reached more quickly. As soon as the correct temperature is reached, the inverter ensures that it is constantly maintained.

Energy efficiency Because an inverter monitors and adjusts ambient temperature whenever needed, energy consumption drops by 30% compared to a traditional on/off (non-inverter) system! 6


Daikin heat pump models Combining the highest efficiency and year-round comfort with a heat pump system.

Heat pump system:

compared to

COP 4.67

Traditional electrical heating system: COP 1

renewable energy (air) energy

1

1

Did you know that ... Air-to-air heat pumps obtain 75% of their output energy from a renewable source: the ambient air, which is both renewable and inexhaustible. Of course, heat pumps also require electricity to run the system, but increasingly this electricity can also be generated from renewable energy sources (solar energy, wind energy, hydropower, biomass). A heat pump’s efficiency is measured in SCOP (Seasonal Coefficient Of Performance) for heating and SEER ( Seasonal Energy Efficiency Ratio) for cooling.

Online Controller To monitor and control your heat pump system from anywhere via app or internet. Connectable to FTXG25-50JA/W, FVXG25-50K, FVXS25-50F and FTXS35-50J

1 Wired controller

2

PC

3 Smartphone

7


Indoor units are quiet in operation: whisper quiet!

A heating and cooling system should be unobtrusive and that is why Daikin has designed their indoor units to be whisper quiet in operation. All our indoor units can operate below the sound of a quiet conversation and the floor standing Nexura system and our wall mounted FTXS-K series, at 19 dBA, are even more quiet – barely above the sound of rustling leaves.

Sound Scale in dB(A) 100

A plane which takes off

60

Conversation between people

30

Quiet conversation

Whisper quiet Rustling leaves

20 10

Nexura system & FTXS-K series

Pure in-house air For healthy living, it is essential that the air we breathe is clear of dust, bacteria and other harmful particles. To address this, Daikin has fitted their indoor units with a two-stage air filtration system. The air is first passed through an air filter that captures the larger particles such as dust; it is then passed through our special titanium photocatalytic air purification filter . This traps microscopic particles while, at the same time, decomposing odours and deactivating and killing bacteria, viruses and microbes to ensure only clean pure air enters the house.

Dirty air

Clean air Air filter: catches dust

8

Titanium apatite photocatalytic air purification filter: traps microscopic particles, decomposes odours and even deactivates bacteria and viruses.


9


FTXG-JW/A / RXLG-K

Wall Mounted Unit

emura

FTXG-JW

FTXG-JA

FORM. FUNCTION. REDEFINED. Comfort & Efficiency ›› ›› ›› ›› ›› ›› ›› ›› ›› ››

Remarkable blend of iconic design and engineering excellence with an elegant finish in brushed aluminium or matt crystal white Optimised heating solution for your home Energy efficient units: seasonal efficiency ratings up to A++ Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Movement sensor saves power consumption in unoccupied rooms and restarts when a person enters the room Night set mode saves energy by preventing overcooling or overheating during night time Indoor/outdoor unit silent operation: “silent” buttons on the remote control lower the operating sound of the indoor and/or outdoor unit by 3dBA each Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Filter ››

Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

Outdoor units designed for the cold ›› ››

RXLG-K

10

››

Outdoor units optimised to withstand extreme cold conditions Extended operation range for heating down to -25°C in heating Outdoor units for pair application

ARC466A1


Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity

Min./Nom./Max. Min./Nom./Max. Cooling

Seasonal efficiency (according to EN14825) Heating (Average climate)

Energy label Pdesign SEER Annual energy consumption Energy label Pdesign SCOP Annual energy consumption

EER COP Annual energy consumption Energy label Cooling/Heating Colour Unit HeightxWidthxDepth Unit Cooling High/Nom./Low/Silent operation Fan - Air flow rate Heating High/Nom. Cooling High/Nom. Sound power level Heating High Cooling High/Nom./Low/Silent operation Sound pressure level Heating High/Nom./Low/Silent operation Liquid OD OD Piping connections Gas Drain OD Power supply Phase / Frequency / Voltage

Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight

FTXG25JW

FTXG35JW

FTXG50JW

FTXG25JA

FTXG35JA

FTXG50JA

kW kW

1.3/2.5 /3.0 1.3/3.4 /4.5

1.4/3.5 /3.8 1.4/4.0 /5.0

1.3/2.5 /3.0 1.3/3.4 /4.5

1.4/3.5 /3.8 1.4/4.0 /5.0

kW

2.50 6.53 134

1.7/5.0/5.3 1.7/5.8/6.5 A 5.00 5.45 321 A 4.60 3.83 1,682 3.21 3.6 780

1.7/5.0/5.3 1.7/5.8/6.5 A 5.00 5.45 321 A 4.60 3.83 1,682 3.21 3.63 780

A++

kWh

A+ kW kWh

kWh

Unit HeightxWidthxDepth Unit Cooling High/Super low Fan - Air flow rate Heating High/Super low High Sound power level Cooling Cooling High/Silent operation Sound pressure level Heating High/Silent operation Cooling Ambient Min.~Max. Operation range Heating Ambient Min.~Max. Type/GWP Refrigerant Piping length OU - IU Max. Piping connections Level difference IU - OU Max. Phase / Frequency / Voltage Power supply Current - 50Hz Maximum fuse amps (MFA)

2.80 4.25 923 4.46 4.36 280

3.30 4.16 1,112 3.93 4.04 445

A++ 2.50 6.53 134

3.50 6.51 188 A+

2.80 4.25 923 4.46 4.36 280

3.30 4.16 1,112 3.93 4.04 445

A/A Matt crystal white mm kg m³/min m³/min dBA dBA dBA dBA mm mm mm Hz / V

OUTDOOR UNIT Dimensions Weight

3.50 6.51 188

8.8/6.8/4.7/3.8 9.6/7.9 54/56 55 38/32/25/22 39/34/28/25

10.1/7.3/4.6/3.9 10.8/8.6 58/60 58 42/34/26/23 42/36/29/26

9.5 16 or 18

RXLG25K mm kg m³/min m³/min dBA dBA dBA °CDB °CWB m m Hz / V A

Brushed aluminium 295x915x155 11 10.3/8.5/6.7/5.7 8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 11.4/9.8 9.6/7.9 10.8/8.6 60/60 54/56 58/60 60 55 58 44/40/35/32 38/32/25/22 42/34/26/23 44/40/35/32 39/34/28/25 42/36/29/26 6.35 12.7 9.5 18 16 or 18 1~ / 50 / 220-240

RXLG35K

550x765x285 34 33.5/30.1 36.0/30.1 28.3/25.6 30.2/25.6 61 46/43 47/44

RXLG50K 735x825x300 48 50.9/48.9 45/43.1 63 48/44 48/45

RXLG25K

10.3/8.5/6.7/5.7 11.4/9.8 60/60 60 44/40/35/32 44/40/35/32

RXLG35K

550x765x285 34 33.5/30.1 36.0/30.1 28.3/25.6 30.2/25.6 61 46/43 47/44

12.7 18

RXLG50K 735x825x300 48 50.9/48.9 45/43.1 63 48/44 48/45

-10~46 -25~18 R-410A/1,975 20 15

30 20

16

20

20 15

30 20

16

20

1~ / 50 / 220-240

(1) EER/COP according to Eurovent 2012

11


FVXG-K / RXLG-K

Floor standing unit with radiant heat panel

Radiant heat

FVXG-K

ARC466A2

The best of two worlds united Comfort & Efficiency ›› ›› ›› ›› ›› ›› ››

›› ›› ›› ››

The aluminium part of the front panel of the Nexura indoor unit has the capability of warming up, just like a traditional radiator, to add even more comfort on cold days Comfortable vertical auto swing ensures draughtfree operation and prevents ceiling soiling Optimised heating solution for your home Energy efficient units: seasonal efficiency ratings up to A++ Night set mode saves energy by preventing overcooling or overheating during night time ECONO mode decreases power consumption so that other appliances that need large power consumption can be used The indoor unit distributes air at the sound of a whisper. The noise produced amounts to barely 22dB(A) in cooling and 19dB(A) in radiant heat mode. In comparison, the ambient sound in a quiet room amounts to 40dB(A) on average Indoor unit silent operation: “silent” buttons on the remote control lower the operating sound of the indoor unit by 3dBA each Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Filter ››

Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

Flexible Installation ›› ››

Ideal for installation beneath a window Can be installed against a wall or recessed

Outdoor units designed for the cold ›› Outdoor units optimised

RXLG-K

12

to withstand extreme cold conditions ›› Extended operation range for heating down to -25°C in heating ›› Outdoor units for pair application


Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity

Min./Nom./Max. Min./Nom./Max. Cooling

Seasonal efficiency (according to EN14825) Heating (Average climate)

Energy label Pdesign SEER Annual energy consumption Energy label Pdesign SCOP Annual energy consumption

EER COP Annual energy consumption Energy label Cooling/Heating Colour Unit HeightxWidthxDepth Unit Cooling High/Nom./Low/Silent operation Fan - Air flow rate Heating High/Nom. Cooling Nom. Sound power level Heating Nom. Cooling High/Nom./Low/Silent operation Sound pressure level Heating H/N/L/Silent operation/Radiant heat Liquid OD OD Piping connections Gas Drain OD Power supply Phase / Frequency / Voltage Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight

FVXG25K

FVXG35K

FVXG50K

kW kW

1.3/2.5 /3.0 1.3/3.4 /4.5

1.4/3.5/3.8 1.4/4.5 /5.0

kW

2.50 6.46 135 A+ 2.80 4.47 877 4.55 4.36 275

1.7/5.0/5.6 1.7/5.8/8.1 A 5.00 5.31 330 A+ 4.60 4.08 1,577 3.29 (1) 3.67 (1) 760

A++

kWh kW kWh

kWh

mm kg m³/min m³/min dBA dBA dBA dBA mm mm mm Hz / V

OUTDOOR UNIT HeightxWidthxDepth Unit Unit Cooling High/Super low Fan - Air flow rate Heating High/Super low High Sound power level Cooling Cooling High/Silent operation Sound pressure level Heating High/Silent operation Cooling Ambient Min.~Max. Operation range Heating Ambient Min.~Max. Type/GWP Refrigerant Piping length OU - IU Max. Piping connections Level difference IU - OU Max. Phase / Frequency / Voltage Power supply Current - 50Hz Maximum fuse amps (MFA)

Dimensions Weight

3.50 6.33 194 A 3.10 3.87 1,122 3.68 3.72 475 A/A Fresh white (6.5Y 9.5/0.5) 600x950x215 22 9.1/7.2/5.3/4.5 10.2/8.0

8.9/7.0/5.3/4.5 9.9/7.8 52 52 38/32/26/23 39/32/26/22/19

39/33/27/24 40/33/27/23/19 6.35 9.5

m m Hz / V A

12.7 18 1~ / 50 / 220-240

RXLG25K mm kg m³/min m³/min dBA dBA dBA °CDB °CWB

10.6/8.9/7.3/6.0 12.2/10.0 58 58 44/40/36/32 46/40/34/30/26

RXLG35K

RXLG50K

36.0/30.1 30.2/25.6

735x825x300 48 50.9/48.9 45/43.1

550x765x285 34 33.5/30.1 28.3/25.6 61 46/43 47/44

63 48/44 48/45 -10~46 -25~18 R-410A/1,975 20 15

30 20 1~ / 50 / 220-240

16

20

(1) EER/COP according to Eurovent 2012

13


FTXS-K / RXL-K

FTXS-K

ARC466A1

Comfort & Efficiency ›› ›› ›› ›› ›› ›› ›› ››

›› ›› ››

Discreet, modern design. Its smooth curve blends beautifully with the wall resulting in an unobtrusive presence that matches all interior décors. High quality matt crystal white finish Whisper quiet operation: down to 19dBA sound pressure level Optimised heating solution for your home Energy efficient units: seasonal efficiency ratings up to A++ ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode Night set mode saves energy by preventing overcooling or overheating during night time Indoor unit silent operation: “silent” buttons on the remote control lower the operating sound of the indoor unit by 3dBA each Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode

Filter ››

Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

Outdoor units designed for the cold ›› Outdoor units optimised

RXL-K

14

Wall Mounted Unit

to withstand extreme cold conditions ›› Extended operation range for heating down to -25°C in heating ›› Outdoor units for pair application


Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity

Min./Nom./Max. Min./Nom./Max. Cooling

Seasonal efficiency (according to EN14825) Heating (Average climate)

kW kW Energy label Pdesign SEER Annual energy consumption Energy label Pdesign SCOP Annual energy consumption

EER COP Annual energy consumption Energy label Cooling/Heating Colour Unit HeightxWidthxDepth Unit Cooling High/Nom./Low/Silent operation Fan - Air flow rate Heating High/Nom. Cooling Nom. Sound power level Heating Nom. Cooling High/Nom./Low/Silent operation Sound pressure level Heating High/Nom./Low/Silent operation Liquid OD OD Piping connections Gas Drain OD Power supply Phase / Frequency / Voltage Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight

kW kWh kW kWh

kWh

mm kg m³/min m³/min dBA dBA dBA dBA mm mm mm Hz / V

OUTDOOR UNIT Dimensions Weight

Unit HeightxWidthxDepth Unit Cooling High Sound power level Heating High Cooling High/Silent operation Sound pressure level Heating High/Silent operation Cooling Ambient Min.~Max. Operation range Heating Ambient Min.~Max. Type/GWP Refrigerant Piping length OU - IU Max. Piping connections Level difference IU - OU Max. Phase / Frequency / Voltage Power supply Current - 50Hz Maximum fuse amps (MFA)

FTXS20K

FTXS25K

1.3/2.0/2.8 1.3/2.5/4.3 A+ 2.00 5.71 123 A++ 2.30 4.62 698 4.65 4.55 215

1.3/2.5/3.2 1.3/2.8/4.7 A++ 2.50 6.37 137 A+ 2.50 4.51 775 4.39 4.52 285 A/A White 289x780x215 8

8.8/6.7/4.7/3.9 9.5/7.8

9.1/7.0/5.0/3.9 10.0/8.0 58 58

40/32/24/19 40/34/27/19

41/33/25/19 41/34/27/19 6.35 9.5 18 1~ / 50 / 220-240

RXL20K mm kg dBA dBA dBA dBA °CDB °CWB m m Hz / V A

RXL25K 550x765x285 34 62 62 46/43 47/44 -10~46 -25~18 R-410A/1,975 20 15 1~ / 50 / 220-240 10

(1) EER/COP according to Eurovent 2012

15


FTXS-J / RXL-J

Wall Mounted Unit

FTXS-J

ARC452A3

Comfort & Efficiency ›› ›› ››

›› ›› ›› ›› ›› ››

Optimised heating solution for your home Energy efficient units: seasonal efficiency ratings up to A++ 2 area intelligent eye: air flow is sent to a zone other than where the person is located at that moment; if two people are detected in the room, the air flow is projected away from the occupants; if no people are detected, the unit will automatically switch over to the energy-efficient setting ECONO mode decreases power consumption so that other appliances that need large power consumption can be used Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Night set mode saves energy by preventing overcooling or overheating during night time Indoor unit silent operation: “silent” buttons on the remote control lower the operating sound of the indoor unit by 3dBA each Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Filter ››

Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

Outdoor units designed for the cold ›› Outdoor units optimised

RXL-J

16

to withstand extreme cold conditions ›› Extended operation range for heating down to -25°C in heating ›› Outdoor units for pair application


Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity

Min./Nom./Max. Min./Nom./Max. Cooling

Seasonal efficiency (according to EN14825) Heating (Average climate)

kW kW Energy label Pdesign SEER Annual energy consumption Energy label Pdesign SCOP Annual energy consumption

EER COP Annual energy consumption Energy label Cooling/Heating Colour Unit HeightxWidthxDepth Unit Cooling High/Nom./Low/Silent operation Fan - Air flow rate Heating High/Nom. Cooling Nom. Sound power level Heating Nom. Cooling High/Nom./Low/Silent operation Sound pressure level Heating High/Nom./Low/Silent operation Liquid OD OD Piping connections Gas Drain OD Power supply Phase / Frequency / Voltage Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight

kW kWh kW kWh

kWh

mm kg m³/min m³/min dBA dBA dBA dBA mm mm mm Hz / V

OUTDOOR UNIT Dimensions Weight

Unit HeightxWidthxDepth Unit Cooling High Sound power level Heating High Cooling High/Silent operation Sound pressure level Heating High/Silent operation Cooling Ambient Min.~Max. Operation range Heating Ambient Min.~Max. Type/GWP Refrigerant Piping length OU - IU Max. Piping connections Level difference IU - OU Max. Phase / Frequency / Voltage Power supply Current - 50Hz Maximum fuse amps (MFA)

FTXS35J

FTXS42J

FTXS50J

1.4/3.5/4.0 1.4/4.0/5.2 A++ 3.50 6.43 190 A++ 3.60 4.24 1,188 4.07 4.21 430

1.7/4.2/5.0 1.7/5.4/6.0

1.7/5.0/5.3 1.7/5.8/6.5 A

4.20 5.47 269 A 3.90 3.75 1,453 3.47 3.72 605 A/A White 295x800x215 10 11.3/9.0/6.8/5.9 12.2/9.7

11.4/8.7/5.8/4.4 12.4/9.5

m m Hz / V A

4.60 3.94 1,634 3.42 3.79 730

11.6/9.2/7.0/6.0 12.1/9.8 60 60 46/40/34/31 47/41/34/31

59 59 45/37/29/23 45/39/29/26

45/39/33/30 45/39/33/30 6.35 9.5

12.7 18 1~ / 50 / 220-240

RXL35J mm kg dBA dBA dBA dBA °CDB °CWB

5.00 5.30 330

RXL42J

RXL50J 735x825x300 48

550x765x285 34

39 63 63 48/44 48/45 -10~46 -25~18 R-410A/1,975 20 15

30 20 1~ / 50 / 220-240

10

20

(1) EER/COP according to Eurovent 2012

17


FVXS-F / RXL-K/J

FVXS-F

Comfort & Efficiency ›› ›› ›› ›› ›› ›› ›› ››

Optimised heating solution for your home Vertical auto-swing function moves the discharge flaps up and down for efficient air distribution throughout the room Night set mode saves energy by preventing overcooling or overheating during night time Whisper quiet operation: down to 23 dBA sound pressure level Powerful mode can be selected for rapid cooling or heating Home leave operation saves energy during absence Weekly timer: allows to program the unit on a weekly basis Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Filter ››

Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses

Flexible Installation ›› ››

Ideal for installation beneath a window Can be installed against a wall or recessed

Outdoor units designed for the cold ›› ›› ››

Outdoor units optimised to withstand extreme cold conditions Extended operation range for heating down to -25°C in heating Outdoor units for pair application

RXL25K

18

Floor Standing Unit

ARC452A1


Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity

Min./Nom./Max. Min./Nom./Max. Cooling

Seasonal efficiency (according to EN14825) Heating (Average climate)

kW kW Energy label Pdesign SEER Annual energy consumption Energy label Pdesign SCOP Annual energy consumption

EER COP Annual energy consumption Energy label Cooling/Heating Colour Unit HeightxWidthxDepth Unit Cooling High/Nom./Low/Silent operation Fan - Air flow rate Heating High/Nom./Low/Silent operation Cooling High/Nom. Sound power level Heating High/Nom. Cooling High/Nom./Low/Silent operation Sound pressure level Heating High/Nom./Low/Silent operation Liquid OD OD Piping connections Gas Drain OD Power supply Phase / Frequency / Voltage

Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight

kW kWh kW kWh

kWh

mm kg m³/min m³/min dBA dBA dBA dBA mm mm mm Hz / V

OUTDOOR UNIT Dimensions Weight

Unit HeightxWidthxDepth Unit Cooling High Sound power level Heating High Cooling High/Silent operation Sound pressure level Heating High/Silent operation Cooling Ambient Min.~Max. Operation range Heating Ambient Min.~Max. Type/GWP Refrigerant Piping length OU - IU Max. Piping connections Level difference IU - OU Max. Phase / Frequency / Voltage Power supply Current - 50Hz Maximum fuse amps (MFA)

FVXS25F

FVXS35F

FVXS50F

1.3/2.5 /3.0 1.3/3.4 /4.5 B 2.5 4.71 186 A+ 2.60 4.28 850 4.39 4.30 285

1.4/3.50 /3.8 1.4/4.50 /5.0 B 3.50 4.93 248

1.4/5.0 /5.6 1.4/5.8 /8.1 A 5.00 5.53 317 A

2.90 3.83 1,059 3.43 3.69 510 A/A White 600x700x210 14 8.5/6.7/4.9/4.5 9.4/7.3/5.2/4.7 55/52 55/52 39/33/27/24 39/33/27/24 6.35

8.2/6.5/4.8/4.1 8.8/6.9/5.0/4.4 -/52 -/52 38/32/26/23 38/32/26/23

m m Hz / V A

10.7/9.2/7.8/6.6 11.8/10.1/8.5/7.1 56/60 57/60 44/40/36/32 45/40/36/32

9.5

12.7 20 1~ / 50 / 220-240

RXL25K mm kg dBA dBA dBA dBA °CDB °CWB

4.80 3.59 1,874 3.23 3.63 775

RXL35J

RXL50J 735x825x300 48

550x765x285 34 62 62 46/43 47/44

63 63 48/44 48/45 -10~46 -25~18 R-410A/1,975 20 15

30 20 1~ / 50 / 220-240

10

20

(1) EER/COP according to Eurovent 2012

19


Benefits overview We care icons Seasonal efficiency, smart use of energy Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate over an entire heating or cooling season.

INVERTER

Inverter technology In combination with inverter controlled outdoor units

2 area intelligent eye Air flow is sent to a zone other than where the person is located at that moment. If two people are detected in the room, the air flow is projected away from the occupants. If no people are detected, the unit will automatically switch over to the energyefficient setting. Energy saving during operation standby Current consumption is reduced by about 80 % when operating on standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Night set mode Saves energy, by preventing overcooling or overheating during night time.

Comfort Comfort mode The new flap changes the discharge angle horizontally for cooling operation and downward vertically for heating operation. This in order to prevent cold or warm air from blowing directly on the body. Powerful mode If the temperature in the room is too high/low, it can be cooled down/heated quickly by selecting the ‘powerful mode’. After the powerful mode is turned off, the unit returns to the preset mode. Whisper quiet Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neighbourhood. Outdoor unit silent operation Lowers the operation sound of the outdoor unit by 3dB(A) to ensure a quiet environment for the neighbourhood. Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature (heat pump types only). Indoor unit silent operation Lowers the operation sound of the indoor unit by 3dB(A). This function is useful when studying or sleeping. Radiant heat The front panel of the indoor unit radiates additional heat to add to your comfort on cold days

Air flow

Econo mode This function decreases the power consumption so that other applicances that need large power consumption can be used. This function is also energy saving. Movement sensor The sensor detects whether someone is in the room. When the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room.

Fan only The air conditioner can be used as fan, blowing air without cooling or heating.

Air treatment Titanium photocatalytic air purification filter Removes airborne dust particles, decomposes odours and restrains the reproduction of bacteria, viruses, microbes, this to ensure a steady supply of clean air

Remote control & timer Weekly timer Timer can be set to start heating or cooling anytime on a daily or weekly basis.

24 Hour timer Timer can be set to start cooling/heating anytime during a 24-hour period.

Wired remote control Wired remote control to start, stop and regulate the air conditioner from a distance.

Infrared remote control Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance. Centralised control Centralised control to start, stop and regulate several air conditioners from one central point.

Online controller To monitor or control your heat pump system from anywhere via app or internet.

Vertical auto swing Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature distribution. Auto fan speed Automatically selects the necessary fan speed to reach or maintain the set temperature. Horizontal auto swing Possibility to select automatic horizontal moving of the air discharge louvre, for uniform air flow and temperature distribution.

Auto-restart The unit restarts automatically at the original settings after power failure.

Fan speed steps Allows to select up to the given number of fan speed.

Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies.

Humidity control Dry programme Allows humidity levels to be reduced without variations in room temperature.

20

Other functions

Multi model application Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode. VRV for residential application Up to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode.


Wall mounted unit

INVERTER

Floor standing unit

FTXG-J

FTXS-K

FTXS-J

FVXG-K

FVXS-F

Inverter technology

Econo mode

We care icons

2 area intelligent eye

Comfort

Movement sensor

Energy saving during operation standby

Night set mode

Fan only

Comfort mode

Powerful mode

Auto cooling-heating changeover

Whisper quiet

Radiant heat Indoor unit silent operation

Outdoor unit silent operation

Vertical auto swing

Fan speed steps

5

5

5

5

5

Dry programme

Air treatment

Titanium photocatalytic air purification filter

Online controller

Weekly timer

24 Hour timer

Infrared remote control

Wired remote control

Centralised control

Auto-restart

Self-diagnosis

Multi model application

VRV for residential application

Remote control & timer

Auto fan speed

Humidity control

Air Flow

Horizontal auto swing

Other funtions

21


22


Notes

23


Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Fan coil units (FCU) and Air handling units (AHU). Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com

FSC The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin products are distributed by:

ECPEN13-004

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

ECPEN13-004 • XXX • 12 / 12 • Copyright Daikin The present publication supersedes ECPEN12-004. Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.