Product portfolio
Chillers and air side equipment
High efficiency and versatility Daikin chillers and air side equipment provide the ultimate in reliability and flexibility. Our chillers, fan coils and air handlers deliver superior efficiency across a wide range of applications. Daikin reimagines and delivers revolutionary air conditioning to the world. As the industry leader, we will continue creating new values by anticipating the future needs of customers for all environments.
Air cooled chillers and condensing units Extra low
Reduced
Low
Standard
Sound version High ambient
Premium
High
Standard
Efficiency version
Screw
Scroll
Swing
Free cooling
Inverter
Refrigerant
Compressor
Cooling only
0
EWAQ~ADVP
R-410A
•
EWAQ~ACV3/ACW1
R-410A
•
EWAQ~BA*
R-410A
•
EWAQ~E-
R-410A
•
EWAQ~F-
R-410A
•
EWAQ~GZ
R-410A
EWAD~E-
R-134a
•
•
EWAD~D-
R-134a
•
•
•
EWAD~C-
R-134a
•
•
•
EWAD~CZ
R-134a
EWAD~CF
R-134a
EWAD~TZ
NEW
R-134a
•
•
•
•
•
•
•
•
•
•
•
•
• • •
•
•
•
•
•
•
•
•
•
• • •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Heat pump
0
EWYQ~ADVP
R-410A
•
EWYQ~ACV3/ACW1
R-410A
•
EWYQ~BA*
R-410A R-410A
SEHVX-AAW SERHQ-AAW1
NEW
•
•
•
•
•
•
•
•
•
•
•
•
•
EWYQ~F-
R-410A
EWYQ~GZ
R-410A
•
EWYD~BZ
R-134a
•
•
•
•
•
•
•
•
•
•
•
•
2
• •
•
Condensing unit ERAD~E-
•
0 R-134a
•
•
•
•
Cooling capacity (kW) Heating capacity (kW) 17.5
200
500
1,000
2,000
5.3~7.2 8.6~17.0 16.6~64.5 172~334 165~672 196~395 98~411 177~620 617~2,002 696~1,795 602~1,555 170~710 17.5
200
500
1,000
2,000
500
1,000
2,000
5.3~7.2 5.6~8.2 8.6~17.0 9.9~14.8 16.6~64.5 16.2~63.7 20.7~74.3 21.3~63.7 158~624 173~674 188~380 182~362 247~580 271~618 17.5
200 116~488
3
Water cooled and condenserless chillers
Sound version Standard
High
Standard
Efficiency version Centrifugal
Screw
Scroll
Inverter
Refrigerant
Compressor
Water cooled chillers (Cooling only & Heating only)
•
•
•
•
•
R-134a
•
•
•
•
EWWD~I-
R-134a
•
•
•
•
EWWD~H-
R-134a
•
•
•
R-410A
•
•
•
EWWP~KBW1N
R-407C
EWWD~J-
R-134a
EWWD~G-
•
Water cooled chillers (Cooling only) EWWQ~B-
•
Condenserless chillers
•
•
•
•
•
R-134a
•
•
•
R-134a
•
•
•
EWLP~KBW1N
R-407C
EWLD~J-
R-134a
EWLD~GEWLD~I-
•
Water cooled centrifugal chillers EWWD~FZ
R-134a
•
•
•
•
DWSC DWDC
R-134a
optional
•
•
•
6,000 RT CENTRIFUGAL
R-134a
•
•
•
4
Cooling capacity (kW) Heating capacity (kW) 0
17.5
200
500
1,000
2,000 21800
1,000
2,000 21800
1,000
2,000 21800
1,000
2,000 21800
12.9~194 16.7~249 120~568 142~681 165~602 209~743 332~1,503 424~1,951 368~1,212 454~1,488 0
17.5
200
500 379~2,156
0
17.5
200
500
12.1~62.4 110~529 160~524 315~1,433 0
17.5
200
500 113~1,054 300~4,500
600~9,000 [ 2 x 10,900 ]
21,800
5
Fan coil units Type
Ceiling mounted cassette
Model
FWG-AT/AF
Round flow cassette - Brushless DC fan motor unit for ceiling mounting - 360째 air discharge ensures uniform air flow - Integrated fresh air intake - Easy installation in corners - Standard drain pump with 850 mm lift
FWC-BT/BF
Cooling: 2.0 - 5.2 kW Heating: 2.9 - 6.7 kW
4-way blow ceiling mounted cassette - AC fan motor unit for ceiling mounting - Integrated fresh air intake - Horizontal auto swing - Easy installation in corners - Standard drain pump with 750 mm lift
FWF-BT/BF
Cooling: 2.49 - 4.54 kW Heating: 3.52 - 5.28 kW
4-way blow ceiling mounted cassette - AC fan motor unit for ceiling mounting - Easy installation and maintenance - High power air flow - Standard drain pump with 700 mm lift
FWF-CT
Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW
FWZ-AT/AF
Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW
FWV-DAT/DAF
Cooling: 1.46 -8.02 kW Heating: 1.90 - 10.03 kW
FWR-AT/AF
Cooling: 2.64 - 10.08 kW Heating: 2.46- 11.18 kW
FWL-DAT/DAF
Cooling: 1.46 - 8.02 kW Heating: 1.90 - 10.03 kW
FWS-AT/AF
Cooling: 2.64 - 10.08 kW Heating: 2.46 - 11.18 kW
FWM-DAT/DAF
Cooling: 1.46 -8.02 kW Heating: 1.90 - 10.03 kW
FWT-CT
Cooling: 2.43 - 5.28 kW Heating: 3.22 - 7.33 kW
FWE-CT/CF
Cooling: 2.10 - 9.96 kW Heating: 2.3 - 13.00 kW
Medium ESP ducted unit - Brushless DC fan motor unit for horizontal concealed mounting - Instant adjustment to temperature and relative humidity changes - Available static pressure up to 80 Pa - Low sound levels
FWP-AT
Cooling: 2.61 - 6.47 kW Heating: 5.47 - 12.28 kW
Medium ESP ducted unit - AC fan motor unit for horizontal concealed mounting - Available static pressure up to 80 Pa - 7-speed electrical motors (thermal protection on windings) - Easy maintenance
FWB-BT
Cooling: 2.61 - 10.34 kW Heating: 5.47 - 18.78 kW
FWD-AT/AF
Cooling: 3.90 - 18.30 kW Heating: 4.05 - 21.92 kW
Floor standing unit - AC fan motor unit for horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance Flexi type unit with cabinet - Brushless DC fan motor unit for horizontal or vertical mouting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels Flexi type unit with cabinet - AC fan motor unit for horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance
Flexi type unit
Flexi type unit without cabinet - Brushless DC fan motor unit for horizontal or vertical concealed mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels Flexi type unit without cabinet - AC fan motor unit for horizontal or vertical concealed mounting - Insulated valve packages, no extra drain pan required - Fast-on connections for electrical options: no tools needed - Easy maintenance
Wall mounted unit
Wall mounted unit - AC fan motor unit for wall mounting - High aesthetic cabinet design - Optimum air distribution - Easy installation - 3-speed fan motor Low ESP ducted unit - AC fan motor unit for horizontal concealed mounting - Available static pressure up to 50 Pa - Easy installation and maintenance - 4-speed fan motor - High power air flow
Concealed ceiling unit
High ESP ducted unit - AC fan motor unit for horizontal or vertical concealed mounting - Available static pressure up to 120 Pa - Easy maintenance
6
Capacity
4-way blow ceiling mounted cassette - Brushless DC fan motor unit for ceiling mounting - High efficiency, continuous air flow regulation and fan speed modulation - Reduced sound emissions - Easy installation and maintenance
Floor standing unit - Brushless DC fan motor for vertical mounting - Continuous air flow regulation and fan speed modulation - Up to 70% energy savings - Low sound levels
Floor standing unit
Product name
NEW
Cooling: 5.8~ 8.7 kW Heating: 7.5 ~ 12.1 kW
Capacity class (kW) 1
2
3
4
5
6
7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
10
•
11
12
~
18
• •
•
• •
• •
•
•
9
• •
•
8
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
•
•
•
•
•
•
•
•
• •
•
• •
•
•
7
Air handling units Air flow (m3/h x 1,000)
D-AHU Professional
Professional
›› Pre-configured sizes ›› Tailored to the individual customer ›› Modular construction
140
120
Energy
D-AHU Energy
100
90
›› High-end solution for optimised energy consumption ›› High efficiency components ›› Strong Return on Investment
Easy
›› Space-optimised unit ›› Preconfigured sizes
Compact
›› Smart design ›› Heat recovery ›› EC fan technology ›› Predefined sizes
80
70
60
50
40
D-AHU Easy
D-AHU Compact
20 750 m3/h up to 144,000 m3/h
750 m3/h
500 m3/h
up to 100,000 m3/h
up to 33,000 m3/h
500m3/h up to 25,000 m3/h
0
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor) Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com
ECPEN15 - 401
450 · 10/14
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. The present publication supersedes ECPEN14-440. Printed on non-chlorinated paper. Prepared by La Movida, Belgium.