2000-90-521tts6x130

Page 1

CODE :

2000.90.521

PT100B-6x130-A304-0000-2,0TTS DESCRIPTION :

PT100B sensor 6x130 mm, 3 wires connection, no process connection with 2m Glass fiber cable.

Glass fiber cable L=3m

3 wires CONNECTION Magnesium Oxide MgO Sensor Detection point

RTD

OPERATING TEMPERATURE : HEAD MATERIAL : IMMERSION MATERIAL : JUNCTION MATERIAL : SENSOR INSULATION : TAPERING : CERTIFICATION : CABLE MATERIAL :

-100°C + 250°C Not available Steel AISI 304 Not available MgO Magnesium Oxide >20Mohm at 25°C (500Vdc) NO NO TTS Glass fiber

Response time of RTD with tube in steel AISI-316/304 MgO insulated, according to B.S. 1904/1984/CEI60751. 50mm water immersion at 1m/sec. speed calculated on 63,2% of thermal gradient, according to stem diameter and thickness. ΔΤ 100% 63.2%

t

CONNECTION CABLE FEATURES SHEATH MATERIAL PVC GSC Silicon rubber TFE Teflon KAP Kapton TTS Glass fiber TTC Ceramic fiber

TEMPERATURE [°C]

ABRASION HUMIDITY RESISTANCE RESISTANCE

FLAME BEHAVIOUR

EXERCISE

INSTANTANEOUS

-30 / + 105

+ 105

Good

Good

Self-extinguish

-40 / + 250

+ 250

Sufficient

Fair

Self-extinguish

-200 / + 260

+ 310

Excellent

Excellent

Self-extinguish

-200 / + 400

+ 440

Fair

Good

Self-extinguish

-200 / + 500

+ 500

Poor

Poor

Inconbustible

+ 1000

+ 1100

Poor

Poor

Inconbustible

Time

External diameter

Internal diameter

t=Time

6 mm 8 mm 10 mm

5 mm 7 mm 9 mm

6,5 S 8,3 S 10,2 S

TEMPERATURE

°C -200 -100 0 100 200 300

TOLERANCE PT100

B Class (+/-°C) 1.3 0.8 0.3 0.8 1.3 1.8