Specifications CXDI-710C Wireless

System Structure Example

General Radiography

Purpose

Operator Room

Sensor

LANMIT

Method

Scintillator & Amorphous Silicon (a-Si) CsI (Cesium Iodide)

Scintillator

125 × 125 μm

Pixel Pitch Total Pixel Count

2,800 × 3,408 (Approx. 9.5 Million)

Exposure Range

Automatic Range Detection (Max. 350 × 426 mm) Approx. 4 Digits

Dynamic Range

Docking Station

4,096 Steps (12-bit)

Greyscale

65,536 Steps (16-bit)

A/D

Control Station

DICOM 3.0 Compatible, Print Management Service Class (SCU),

DICOM

Storage Service Class (SCU) (JPEG Transfer Syntax Available) Temperature: 5 to 35°C / Humidity: 30 to 80%

Operating Environment

Battery Charger

AC 100V–240V (50/60 Hz)

Voltage Power Consumption

Instantaneous Maximum Load: Up to 78 VA / Standby: Up to 25 W

External Dimensions

384 (W) × 460 (D) × 15.7 (H) mm

Image Capture Room

2.3 kg

Weight (incl. battery)

100 kg @ Ø40mm, 310 kg @ Entire Area

Load Tolerance

IEEE 802.11a/b/g/n (2.4/5.0 GHz)

Wireless Standard

WPA2-PSK (AES)

Encryption

Standard Mode: Battery Specification *1

Maximum 1,000 Images @ 7 Sec. Cycle / Average 140 Images @ 100 Sec. Cycle CXDI-710C Wireless

X-Ray Automatic Detection Mode: Maximum 1,000 Images @ 7 Sec. Cycle / Average 110 Images @ 100 Sec. Cycle

Wiring Cable

Docking Station Charger: Approx. 120 mins.

Battery Charge Time

Multibox

Access Point

Wireless Versatility

Battery Charger: Approx. 150 mins. IPX7*2

Water-resistance Rating

99 Images

On-board Image Storage

Recommended: 52 lines/cm (compatible with 34, 40, 60 lines)*3

Grid

7 years

Service Life

*1 May vary based on operating and environmental factors such as ambient temperature. *2 Based on tests conducted by an independent institution. Certification does not guarantee against failure or damage. Water resistance may be compromised by substantial impacts (dropping, crushing, etc.). *3 Usage restrictions exist. For details, contact the Canon sales team.

Vertical Stand

Status Indicator

X-ray Generator

[Optional]

Docking Station

Battery Charger

Multibox

Wiring Cable

Status Indicator

Specifications are subject to change without notice. Names of companies or products appearing in this document are trademarks and/or registered trademarks of their respective owners.

CANON INC. MEDICAL EQUIPMENT GROUP 30-2, Shimomaruko 3-chome, Ohta-ku, Tokyo 146-8501, Japan Telephone: +81-3-3758-2111 Fax: +81-3-5482-3960 CANON SINGAPORE PTE. LTD. Medical Equipment Dept. 1 Fusionopolis Place, #15-10 Galaxis, Singapore 138522 Telephone: +65-6799-8888 Fax: +65-6799-8882 http://www.canon.com.sg/business/products/digital-radiography/

CANON AUSTRALIA PTY. LTD. Building A, The Park Estate, 5 Talavera Road, Macquarie Park, NSW, 2113, Australia Telephone: +61-2-9805-2074 Email: specialised.imaging@canon.com.au http://www.canon.com.au/Medical CANON KOREA BUSINESS SOLUTIONS INC. MEDICAL EQUIPMENT BUSINESS TEAM 607, Teheran-ro, Gangnam-gu, Seoul, Rep. of KOREA Telephone: +82-2-3450-0727 Fax: +82-2-3456-0655 https://www.canon-bs.co.kr Code: E009E1 © CANON INC. 2017

Light Water weight proof


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.