Specifications CXDI-710C Wireless
System Structure Example
General Radiography
Purpose
Operator Room
Sensor
LANMIT
Method
Scintillator & Amorphous Silicon (a-Si) CsI (Cesium Iodide)
Scintillator
125 × 125 μm
Pixel Pitch Total Pixel Count
2,800 × 3,408 (Approx. 9.5 Million)
Exposure Range
Automatic Range Detection (Max. 350 × 426 mm) Approx. 4 Digits
Dynamic Range
Docking Station
4,096 Steps (12-bit)
Greyscale
65,536 Steps (16-bit)
A/D
Control Station
DICOM 3.0 Compatible, Print Management Service Class (SCU),
DICOM
Storage Service Class (SCU) (JPEG Transfer Syntax Available) Temperature: 5 to 35°C / Humidity: 30 to 80%
Operating Environment
Battery Charger
AC 100V–240V (50/60 Hz)
Voltage Power Consumption
Instantaneous Maximum Load: Up to 78 VA / Standby: Up to 25 W
External Dimensions
384 (W) × 460 (D) × 15.7 (H) mm
Image Capture Room
2.3 kg
Weight (incl. battery)
100 kg @ Ø40mm, 310 kg @ Entire Area
Load Tolerance
IEEE 802.11a/b/g/n (2.4/5.0 GHz)
Wireless Standard
WPA2-PSK (AES)
Encryption
Standard Mode: Battery Specification *1
Maximum 1,000 Images @ 7 Sec. Cycle / Average 140 Images @ 100 Sec. Cycle CXDI-710C Wireless
X-Ray Automatic Detection Mode: Maximum 1,000 Images @ 7 Sec. Cycle / Average 110 Images @ 100 Sec. Cycle
Wiring Cable
Docking Station Charger: Approx. 120 mins.
Battery Charge Time
Multibox
Access Point
Wireless Versatility
Battery Charger: Approx. 150 mins. IPX7*2
Water-resistance Rating
99 Images
On-board Image Storage
Recommended: 52 lines/cm (compatible with 34, 40, 60 lines)*3
Grid
7 years
Service Life
*1 May vary based on operating and environmental factors such as ambient temperature. *2 Based on tests conducted by an independent institution. Certification does not guarantee against failure or damage. Water resistance may be compromised by substantial impacts (dropping, crushing, etc.). *3 Usage restrictions exist. For details, contact the Canon sales team.
Vertical Stand
Status Indicator
X-ray Generator
[Optional]
Docking Station
Battery Charger
Multibox
Wiring Cable
Status Indicator
Specifications are subject to change without notice. Names of companies or products appearing in this document are trademarks and/or registered trademarks of their respective owners.
CANON INC. MEDICAL EQUIPMENT GROUP 30-2, Shimomaruko 3-chome, Ohta-ku, Tokyo 146-8501, Japan Telephone: +81-3-3758-2111 Fax: +81-3-5482-3960 CANON SINGAPORE PTE. LTD. Medical Equipment Dept. 1 Fusionopolis Place, #15-10 Galaxis, Singapore 138522 Telephone: +65-6799-8888 Fax: +65-6799-8882 http://www.canon.com.sg/business/products/digital-radiography/
CANON AUSTRALIA PTY. LTD. Building A, The Park Estate, 5 Talavera Road, Macquarie Park, NSW, 2113, Australia Telephone: +61-2-9805-2074 Email: specialised.imaging@canon.com.au http://www.canon.com.au/Medical CANON KOREA BUSINESS SOLUTIONS INC. MEDICAL EQUIPMENT BUSINESS TEAM 607, Teheran-ro, Gangnam-gu, Seoul, Rep. of KOREA Telephone: +82-2-3450-0727 Fax: +82-2-3456-0655 https://www.canon-bs.co.kr Code: E009E1 © CANON INC. 2017
Light Water weight proof