Atomscope HFX90V Equine Technique Chart

Page 1

DLC Australia Pty Ltd Sourthern Office: 17-19 Horne Street Hoppers Crossing, Vic 3029 Ph:0393609700 Nothern Office: 6/1 Learjet Drive Caboolture Qld 4510 Ph:0754283666 February 2009

EXPOSURE TIME TABLE FOR EQUINE PRACTICE Values are for High-Frequency X-Ray unit Atomscope HFX90V with orthochromatic intensifying screens (”RARE EARTH” - Gadoliniumoxybromide), G R E E N S E N S I T I V E Factor 400. In order to obtain uniform quality of radiographs, it is important to use same filmand chemical brand products consistently. Low quality film material can cause considerable image problems. All data are standard values, slight adjustments might be necessary, depending on the conditions at site. As a general rule, exposures with utilization of an X-ray grid need 2 - 3 times longer exposure times. REGION

X-RAY GRID

FFD cm

KV

TIME sec

Columna vertebralis thoracalis Carpus a-p soft Carpus lateral (flexed) soft Carpus lateral (latero-lateral) hard Processus spinales vertebrae cerv/th Processus spinales vertebrae thorac Processus spinales vertebrae th/ lumb Articulatio cubiti (lateral) Art. metacarpo/-tarsophalangea lat. Os sesamoideum proximale Ossa metacarpalia/-tarsalia II + IV Vertebrae cerviales Phalanx distalis a-p Articulatio genus p-a Articulatio genus (lateral) Caput p-a Caput (lateral) Diverticulum tubae auditivae Articulatio humeri Os naviculare (Oxspring)60°a-p hard Os naviculare (Oxspring) 60°a-p soft Tangential Ueltschi Tarsus a-p Tarsus (lateral) Dentes latero-lateral Dentes ap Digitus III manus/pedis (lat.) hard Digitus III manus/pedis (lat.) soft

w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid with Grid with Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid w/o Grid

75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75

90 66-70 66 74 70 74 78 80 70 66 60 76 76 80 74 78 66 70 84 74 70 60 74 74 74 74 70 60

0.20 0.05 0,08 0,06 0,08 0,12 0,16 0,12 0,08 0,06 0,06 0,12-0,16 0,08 0,30 0,20 0,12 0,22 0,14 0,30 0,26 0,30 0,22 * 0,12 0,08 0,10 0,20 0,08 0,12

75 75 75 75 75 75

KV

TIME sec.

All values are based on medium sized horse

*

When utilizing intensifying screens factor 200 or Mammography-Film 60 kV / 0,50 sec.