Slab Edge Detail (Rebate)
DETAILED DRAWINGS
Nasahi Approved Coating System Metal Batten
Sarking (Recommended) Batten Fixing Internal Wall Lining
Nasahi Panel Panel Fixing DPC
Slab Edge Detail
Max. Panel Overhang 250mm
Min. Rebate Depth (Overhanging) as per NCC
2-3mm Gap F.G.L
Reinforced Concrete Slab
Slab Edge Detail (Rebate)
Sarking (Recommended) Nasahi Approved Coating Nasahi Panel
Batten Fixing Internal Wall Lining
Panel Fixing
20mm Min.
DPC
Cavity Closer Strip (Recommended) FGL
Slab Edge Detail (Overhanging Deepened Edge Beam) Slab Edge Detail (Overhanging) Sarking (Recommended) Batten Fixing
Nasahi Approved Coating
Internal Wall Lining
Nasahi Panel Panel Fixing
Cavity Closer Strip (Recommended)
Flexible Sealant and Backing Rod DPC Masonry Bolts
(ø8mm Zinc Plated)
FGL
20mm Min.
Slab Edge Detail (Overhanging Deepened Edge Beam)
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
Sarking (Recommended) Nasahi Approved Coating
Metal Batten Internal Wall Lining
Nasahi Panel
Batten Fixing Panel Fixing Stepdown as per NCC
Engineered Floor Joists
Cement Sheet Caulking Skirting Tile (Optional) Screed (Slope as per NCC) Waterproof Membrane
Paving Tiles Cement Sheet
DETAIL 1.4 - Balcony Detail (Timber Frame)
Sarking (Recommended) Panel Fixing
Batten Fixing
Nasahi Approved Coating
Metal Batten Internal Wall Lining
Nasahi Panel
Flashing (Min. height 150mm)
Skirting Tile (Optional)
Stepdown as per NCC
Screed (Slope as per NCC) Paving Tiles Waterproofing Membrane
DETAIL 1.5 - Balcony Detail (Concrete Slab)
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
Sarking (Recommended) Panel Fixing Nasahi Approved Coating System 100mm Bugle Head Fixing @ 600mm Ctrs Batten Fixing Metal Batten Nasahi Panel Panel Adhesive
DETAIL 2.1 - External Corner Detail
5-10mm Extra Stud
Sarking (Recommended)
Batten Fixing Panel Fixing
Metal Batten Nasahi Panel Expansion Joint Nasahi Approved Coating System
DETAIL 2.2 - Internal Corner Detail
*NOTE: Internal corners require an extra stud for panel attachment 150mm back from the internal corner.
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS Sarking (Recommended) Nasahi Approved Coating System Nasahi Panel
Batten Fixing
Metal Batten
Internal Wall Lining
Panel Fixing Flashing Flexible Sealant and Backing Rod Window
Internal Wall Lining Metal Batten
DETAIL 3.1 - Window Head
Batten Fixing Flashing Window
Sarking (Recommended)
Nasahi Approved Coating System
Flexible Sealant and Backing Rod Panel Fixing Nasahi Panel
DETAIL 3.2 - Window Jamb
Window Rubber Seal
(By Window Manufacturer)
Min. 15ยบ Fall
10mm Min.
Flashing
Optional Decorative Trim Panel Fixing
Batten Fixing Internal Wall Lining
Nasahi Panel
Metal Batten
Nasahi Approved Coating System
Sarking (Recommended)
DETAIL 3.3 - Window Sill (Decorative Trim)
Window Rubber Seal
(By Window Manufacturer)
Flashing
10mm Min. Min. 15ยบ Fall
Batten Fixing
Panel Fixing
Internal Wall Lining
Nasahi Panel
Metal Batten
Nasahi Approved Coating System
Sarking (Recommended)
DETAIL 3.4 - Window Sill
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
DETAIL 4.1 - Flush Eave
DETAIL 4.2 - Eave Detail (Panel Under)
Internal Wall Lining
Panel Fixing
Batten Fixing
Nasahi Panel
Metal Batten
Nasahi Approved Coating System
Sarking (Recommended)
DETAIL 4.1 - Flush Eave
Eave Detail (Panel Flush With Lining)
Internal Wall Lining
Quad Trim (Optional)
Metal Batten
Panel Fixing
Batten Fixing
Nasahi Panel Nasahi Approved Coating System
Sarking (Recommended)
DETAIL 4.2 - Eave Detail (Panel Under)
Internal Wall Lining Batten Fixing
Quad Trim (Optional)
Panel Fixing
Nasahi Panel
Metal Batten
Nasahi Approved Coating System
DETAIL 4.3 - Eave Detail (Panel Flush With Lining)
Sarking (Recommended)
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
Cladding To Brick Detail
Nasahi Approved Coating System
Metal Batten
Nasahi Panel
Internal Wall Lining
Panel Fixing
Batten Fixing
Panel to Angle Roof Detail (25º)
‘Z’ Flashing
(Behind Sarking)
5-10mm Gap
Sarking (Recommended) Sarking (Recommended)
DETAIL 5.1 - Cladding To Brick Detail Nasahi Approved Coating System Nasahi Panel Panel Fixing 10mm Min. Roof Tiles
Panel to Flat Roof Detail
Batten Fixing Metal Batten Internal Wall Lining Cavity Closer Strip (Recommended) Flashing
(Behind Sarking)
DETAIL 5.2 - Panel to Angle Roof Detail (Up to 25º)
Sarking (Recommended) Nasahi Approved Coating System
Batten Fixing Metal Batten
Panel Fixing
Cavity Closer Strip (Recommended)
Nasahi Panel Roofing
35mm Min.
Flashing
Roof Structure
DETAIL 5.3 - Panel to Flat Roof Detail
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
Inter Floor Junction (No Panel Joint in Joist Zone)
Inter Floor Junction
Sarking (Recommended) Nasahi Approved Coating
Sarking (Recommended)
Internal Wall Lining
Panel Adhesive
Batten Fixing
Nasahi Panel
Nasahi Approved Coating
Flexible Sealant and Backing Rod (Control Joint)
Inter Floor Joist Zone
Internal Wall Lining Batten Fixing
Nasahi Panel Metal Batten
Metal Batten
Panel Fixing
Panel Fixing
Engineered Floor Joists ( ZOYPURHNL
DETAIL 6.1 - Inter Floor Junction (Panel Joint in Joist Zone)
Note: For engineered floor joists, shrinkage V]LY KLW[O VM QVPZ[ panel gap of 5-10mm is acceptable. For non-engineered floor joists, panel gap of 15-20mm is required
Engineered Floor Joists Note: To avoid control joint the joist must close within 600mm panel Inter Floor Joist Zone
DETAIL 6.2 - Inter Floor Junction (No Panel Joint in Joist Zone)
Column Detail
DETAIL 7.1 - Meter Box Installation
Nasahi Approved Coating Nasahi Panel Metal Batten Panel Fixing Flashing
Sarking (Recommended)
Inter Floor Joist Zone
Panel to Panel 100mm Bugle Head Fixing @ 600mm Centres
Batten Fixing Internal Wall Lining
Panel Fixing Nasahi Panel Nasahi Approved Coating
Flexible Sealant and Backing Rod
Panel Adhesive
Meter Box
DETAIL 7.1 - Meter Box Installation
www.nasahi.net.au
DETAIL 8.1 - Column Detail
1300 2 NASAHI
DETAILED DRAWINGS
Parapet Detail
Nasahi Panel
Parapet Capping (By Others)
Batten Fixing
Panel Fixing Cavity Closer Strip (Recommended)
Nasahi Approved Coating
Min. 10mm
Metal Batten
Metal Flashing
Expansion Joint Roofing Fixing (Horizontal) Roof Batten
Sarking (Recommended)
DETAIL 9.1 - Parapet Detail
Nasahi Approved Coating Flexible Sealant and Backing Rod
Panel Gap*
Nasahi Panel
5-10mm
DETAIL 10.1 - Expansion Joint (Horizontal)
*NOTE: Panel gap can be between 5-8mm for an engineered joist frame (shrinkage less than 1%), for non-seasoned joists check with frame manufacturer, or provide 15-20mm.
Nasahi Panel Nasahi Approved Coating Flexible Sealant and Backing Rod
DETAIL 10.2 - Expansion Joint (Vertical)
Light Duty Fixing Anchor
Nasahi Approved Coating
Rainwater Downpipe
Nasahi Panel Bracket Fixing
DETAIL 11.1 - External Fixings to Wall
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
Nasahi Panel Panel Fixing 16mm Batten To Every Stud (Max 600mm Crs) Internal Wall Lining To Be Used Where External Access To Wall Is Available
DETAIL 12.1 - Standard External Wall Detail
Existing Building
20mm Or 50mm Depending On Boundary Wall Installation Method (Stand Up Frame Or Slide In Panels)
Nasahi Panel Panel Fixing (45mm Hex Head Screws) Top Hat Top Hat Fixing (1 leg fixed @ 600mm crs the second leg fixed to top plate, noggins and bottom plates) Internal Wall Lining To Be Used Where External Access To Wall Is Not Available
DETAIL 12.2 - Boundary Wall Fixing Detail A
Existing Building
20mm Or 50mm Depending On Boundary Wall Installation Method (Stand Up Frame Or Slide In Panels)
Nasahi Panel Batten Clip To Top Plate, Noggings & Bottom Plate (Max 600mm Crs) Internal Wall Lining To Be Used Where External Access To Wall Is Not Available
DETAIL 12.3 - Boundary Wall Fixing Detail B
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS min. 50mm
Capping over Boundary Wall Cavity (Recommended)
min. 50mm
Existing Dwelling
Roof Detail as per NCC
Capping over Boundary Wall Cavity (Recommended)
Roof Detail as per NCC Existing Dwelling Metal Tophat
Metal Tophat
Tophat fixing
Tophat fixing
Internal Wall Lining
Internal Wall Lining Panel Adhesive
Panel Adhesive
Panel Fixing
Nasahi Panel
Panel Fixing
Nasahi Panel
DPC 150 step down 2-3mm Gap
DPC 150 step down 2-3mm Gap
min. 70mm
min. 70mm
DETAIL 13.1 - Boundary Wall Detail (Even Slab)
DETAIL 13.2 - Boundary Wall Detail (Uneven Slabs)
www.nasahi.net.au
1300 2 NASAHI
DETAILED DRAWINGS
min. 20mm
min. 20mm
Capping over Boundary Wall Cavity (Required)
Capping over Boundary Wall Cavity (Required)
Existing Dwelling Roof Detail as per NCC
Roof Detail as per NCC
Existing Dwelling Metal Tophat
Metal Tophat Tophat fixing
Tophat fixing
Internal Wall Lining
Internal Wall Lining Panel Adhesive
Panel Fixing
Panel Adhesive
Nasahi Panel
Panel Fixing
Nasahi Panel
DETAIL 13.3 - Boundary Wall Detail (Even Slab, Without Slab Rebate)
DETAIL 13.4 - Boundary Wall Detail (Uneven Slabs, Without Slab Rebate)
www.nasahi.net.au
1300 2 NASAHI