Technical Detail Drawings

Page 1

Slab Edge Detail (Rebate)

DETAILED DRAWINGS

Nasahi Approved Coating System Metal Batten

Sarking (Recommended) Batten Fixing Internal Wall Lining

Nasahi Panel Panel Fixing DPC

Slab Edge Detail

Max. Panel Overhang 250mm

Min. Rebate Depth (Overhanging) as per NCC

2-3mm Gap F.G.L

Reinforced Concrete Slab

Slab Edge Detail (Rebate)

Sarking (Recommended) Nasahi Approved Coating Nasahi Panel

Batten Fixing Internal Wall Lining

Panel Fixing

20mm Min.

DPC

Cavity Closer Strip (Recommended) FGL

Slab Edge Detail (Overhanging Deepened Edge Beam) Slab Edge Detail (Overhanging) Sarking (Recommended) Batten Fixing

Nasahi Approved Coating

Internal Wall Lining

Nasahi Panel Panel Fixing

Cavity Closer Strip (Recommended)

Flexible Sealant and Backing Rod DPC Masonry Bolts

(ø8mm Zinc Plated)

FGL

20mm Min.

Slab Edge Detail (Overhanging Deepened Edge Beam)

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

Sarking (Recommended) Nasahi Approved Coating

Metal Batten Internal Wall Lining

Nasahi Panel

Batten Fixing Panel Fixing Stepdown as per NCC

Engineered Floor Joists

Cement Sheet Caulking Skirting Tile (Optional) Screed (Slope as per NCC) Waterproof Membrane

Paving Tiles Cement Sheet

DETAIL 1.4 - Balcony Detail (Timber Frame)

Sarking (Recommended) Panel Fixing

Batten Fixing

Nasahi Approved Coating

Metal Batten Internal Wall Lining

Nasahi Panel

Flashing (Min. height 150mm)

Skirting Tile (Optional)

Stepdown as per NCC

Screed (Slope as per NCC) Paving Tiles Waterproofing Membrane

DETAIL 1.5 - Balcony Detail (Concrete Slab)

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

Sarking (Recommended) Panel Fixing Nasahi Approved Coating System 100mm Bugle Head Fixing @ 600mm Ctrs Batten Fixing Metal Batten Nasahi Panel Panel Adhesive

DETAIL 2.1 - External Corner Detail

5-10mm Extra Stud

Sarking (Recommended)

Batten Fixing Panel Fixing

Metal Batten Nasahi Panel Expansion Joint Nasahi Approved Coating System

DETAIL 2.2 - Internal Corner Detail

*NOTE: Internal corners require an extra stud for panel attachment 150mm back from the internal corner.

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS Sarking (Recommended) Nasahi Approved Coating System Nasahi Panel

Batten Fixing

Metal Batten

Internal Wall Lining

Panel Fixing Flashing Flexible Sealant and Backing Rod Window

Internal Wall Lining Metal Batten

DETAIL 3.1 - Window Head

Batten Fixing Flashing Window

Sarking (Recommended)

Nasahi Approved Coating System

Flexible Sealant and Backing Rod Panel Fixing Nasahi Panel

DETAIL 3.2 - Window Jamb

Window Rubber Seal

(By Window Manufacturer)

Min. 15ยบ Fall

10mm Min.

Flashing

Optional Decorative Trim Panel Fixing

Batten Fixing Internal Wall Lining

Nasahi Panel

Metal Batten

Nasahi Approved Coating System

Sarking (Recommended)

DETAIL 3.3 - Window Sill (Decorative Trim)

Window Rubber Seal

(By Window Manufacturer)

Flashing

10mm Min. Min. 15ยบ Fall

Batten Fixing

Panel Fixing

Internal Wall Lining

Nasahi Panel

Metal Batten

Nasahi Approved Coating System

Sarking (Recommended)

DETAIL 3.4 - Window Sill

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

DETAIL 4.1 - Flush Eave

DETAIL 4.2 - Eave Detail (Panel Under)

Internal Wall Lining

Panel Fixing

Batten Fixing

Nasahi Panel

Metal Batten

Nasahi Approved Coating System

Sarking (Recommended)

DETAIL 4.1 - Flush Eave

Eave Detail (Panel Flush With Lining)

Internal Wall Lining

Quad Trim (Optional)

Metal Batten

Panel Fixing

Batten Fixing

Nasahi Panel Nasahi Approved Coating System

Sarking (Recommended)

DETAIL 4.2 - Eave Detail (Panel Under)

Internal Wall Lining Batten Fixing

Quad Trim (Optional)

Panel Fixing

Nasahi Panel

Metal Batten

Nasahi Approved Coating System

DETAIL 4.3 - Eave Detail (Panel Flush With Lining)

Sarking (Recommended)

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

Cladding To Brick Detail

Nasahi Approved Coating System

Metal Batten

Nasahi Panel

Internal Wall Lining

Panel Fixing

Batten Fixing

Panel to Angle Roof Detail (25º)

‘Z’ Flashing

(Behind Sarking)

5-10mm Gap

Sarking (Recommended) Sarking (Recommended)

DETAIL 5.1 - Cladding To Brick Detail Nasahi Approved Coating System Nasahi Panel Panel Fixing 10mm Min. Roof Tiles

Panel to Flat Roof Detail

Batten Fixing Metal Batten Internal Wall Lining Cavity Closer Strip (Recommended) Flashing

(Behind Sarking)

DETAIL 5.2 - Panel to Angle Roof Detail (Up to 25º)

Sarking (Recommended) Nasahi Approved Coating System

Batten Fixing Metal Batten

Panel Fixing

Cavity Closer Strip (Recommended)

Nasahi Panel Roofing

35mm Min.

Flashing

Roof Structure

DETAIL 5.3 - Panel to Flat Roof Detail

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

Inter Floor Junction (No Panel Joint in Joist Zone)

Inter Floor Junction

Sarking (Recommended) Nasahi Approved Coating

Sarking (Recommended)

Internal Wall Lining

Panel Adhesive

Batten Fixing

Nasahi Panel

Nasahi Approved Coating

Flexible Sealant and Backing Rod (Control Joint)

Inter Floor Joist Zone

Internal Wall Lining Batten Fixing

Nasahi Panel Metal Batten

Metal Batten

Panel Fixing

Panel Fixing

Engineered Floor Joists ( ZOYPURHNL

DETAIL 6.1 - Inter Floor Junction (Panel Joint in Joist Zone)

Note: For engineered floor joists, shrinkage V]LY KLW[O VM QVPZ[ panel gap of 5-10mm is acceptable. For non-engineered floor joists, panel gap of 15-20mm is required

Engineered Floor Joists Note: To avoid control joint the joist must close within 600mm panel Inter Floor Joist Zone

DETAIL 6.2 - Inter Floor Junction (No Panel Joint in Joist Zone)

Column Detail

DETAIL 7.1 - Meter Box Installation

Nasahi Approved Coating Nasahi Panel Metal Batten Panel Fixing Flashing

Sarking (Recommended)

Inter Floor Joist Zone

Panel to Panel 100mm Bugle Head Fixing @ 600mm Centres

Batten Fixing Internal Wall Lining

Panel Fixing Nasahi Panel Nasahi Approved Coating

Flexible Sealant and Backing Rod

Panel Adhesive

Meter Box

DETAIL 7.1 - Meter Box Installation

www.nasahi.net.au

DETAIL 8.1 - Column Detail

1300 2 NASAHI


DETAILED DRAWINGS

Parapet Detail

Nasahi Panel

Parapet Capping (By Others)

Batten Fixing

Panel Fixing Cavity Closer Strip (Recommended)

Nasahi Approved Coating

Min. 10mm

Metal Batten

Metal Flashing

Expansion Joint Roofing Fixing (Horizontal) Roof Batten

Sarking (Recommended)

DETAIL 9.1 - Parapet Detail

Nasahi Approved Coating Flexible Sealant and Backing Rod

Panel Gap*

Nasahi Panel

5-10mm

DETAIL 10.1 - Expansion Joint (Horizontal)

*NOTE: Panel gap can be between 5-8mm for an engineered joist frame (shrinkage less than 1%), for non-seasoned joists check with frame manufacturer, or provide 15-20mm.

Nasahi Panel Nasahi Approved Coating Flexible Sealant and Backing Rod

DETAIL 10.2 - Expansion Joint (Vertical)

Light Duty Fixing Anchor

Nasahi Approved Coating

Rainwater Downpipe

Nasahi Panel Bracket Fixing

DETAIL 11.1 - External Fixings to Wall

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

Nasahi Panel Panel Fixing 16mm Batten To Every Stud (Max 600mm Crs) Internal Wall Lining To Be Used Where External Access To Wall Is Available

DETAIL 12.1 - Standard External Wall Detail

Existing Building

20mm Or 50mm Depending On Boundary Wall Installation Method (Stand Up Frame Or Slide In Panels)

Nasahi Panel Panel Fixing (45mm Hex Head Screws) Top Hat Top Hat Fixing (1 leg fixed @ 600mm crs the second leg fixed to top plate, noggins and bottom plates) Internal Wall Lining To Be Used Where External Access To Wall Is Not Available

DETAIL 12.2 - Boundary Wall Fixing Detail A

Existing Building

20mm Or 50mm Depending On Boundary Wall Installation Method (Stand Up Frame Or Slide In Panels)

Nasahi Panel Batten Clip To Top Plate, Noggings & Bottom Plate (Max 600mm Crs) Internal Wall Lining To Be Used Where External Access To Wall Is Not Available

DETAIL 12.3 - Boundary Wall Fixing Detail B

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS min. 50mm

Capping over Boundary Wall Cavity (Recommended)

min. 50mm

Existing Dwelling

Roof Detail as per NCC

Capping over Boundary Wall Cavity (Recommended)

Roof Detail as per NCC Existing Dwelling Metal Tophat

Metal Tophat

Tophat fixing

Tophat fixing

Internal Wall Lining

Internal Wall Lining Panel Adhesive

Panel Adhesive

Panel Fixing

Nasahi Panel

Panel Fixing

Nasahi Panel

DPC 150 step down 2-3mm Gap

DPC 150 step down 2-3mm Gap

min. 70mm

min. 70mm

DETAIL 13.1 - Boundary Wall Detail (Even Slab)

DETAIL 13.2 - Boundary Wall Detail (Uneven Slabs)

www.nasahi.net.au

1300 2 NASAHI


DETAILED DRAWINGS

min. 20mm

min. 20mm

Capping over Boundary Wall Cavity (Required)

Capping over Boundary Wall Cavity (Required)

Existing Dwelling Roof Detail as per NCC

Roof Detail as per NCC

Existing Dwelling Metal Tophat

Metal Tophat Tophat fixing

Tophat fixing

Internal Wall Lining

Internal Wall Lining Panel Adhesive

Panel Fixing

Panel Adhesive

Nasahi Panel

Panel Fixing

Nasahi Panel

DETAIL 13.3 - Boundary Wall Detail (Even Slab, Without Slab Rebate)

DETAIL 13.4 - Boundary Wall Detail (Uneven Slabs, Without Slab Rebate)

www.nasahi.net.au

1300 2 NASAHI


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.