CS-2000 Technical Brochure - 0714

Page 1

CS-2OOO

®

Industry leading system for more than 8 years with over 20,000 successful cases.

Class III

“The CS-2000 is an indispensable appliance in my treatment of Class III malocclusion.” Dr. Ted Bennion, DMD MS

“A great appliance for Class II and Class III cases. Easy to place and highly effective!”

Class II

Dr. Eric W. Brust, DDS MS

• Easy To Place • Little To No Maintenance • Increased Performance • Increased Control • Up to 5mm of Correction • 350 Grams of Low Continuous Force

New Components!

Phone: 866.346.5665 | Fax: 314.426.1967 | www.dynaflex.com


Your Class II & Class III Solution This revolutionary system will guarantee results with your Class II and Class III orthodontic cases. The CS-2000® Niti springs are a DynaFlex® exclusive, utilizing a patented, low-continuous force (350 grams), closed coil spring and a specially built “key-hole” end which fits over a patented slotted base pivot similar to a Herbst® housing nut.

600

CS-2000® SPRING

Load (g)

500 400 300 200 100 0

10 20 30 40 50 60 Position (mm)

Case photos compliments of Dr. Andy Hayes of St. Louis, MO BEFORE

• Improved Performance • Simple • Effective • Guaranteed Results

AFTER

PUBLISHED ARTICLE Class III correction using an inter-arch spring-loaded module Visit www.dynaflex.com/cs-2000-information/ Authors: Robert Vanlaecken, Michael O Williams, Thomas Razmus, Erdogan Gunel, Chris Martin, Peter Ngan Journal: Progress in Orthodontics

NEWLY RE-DESIGNED: The newly designed collared pivot allows for an arch wire to slide easily through the base and reduces the possibility of abrasion. The new hybrid screw can be active or passive allowing you the ability to lock the pivot to the archwire, if desired. The pivot is designed to be used on the archwire or can also be welded to a band or crown for amazing versatility. * For detailed information on Class III Correction, reference:

“Class III correction using an inter-arch spring loaded module”. Robert VanLaecken, DDS M.S., West Virginia University, Department of Orthodontics.


Easy 10 minute Step By Step Instructions for Archwire Placement Class II

Class III LOWER ARCH

STEP 1:

Place 2 pivots on the upper archwire, position pivots distal to the upper canines, insert and ligate archwire.

STEP 1:

Place 2 pivots on the lower archwire, position pivots distal to the lower canines, insert and ligate archwire. UPPER ARCH

STEP 2:

STEP 2:

STEP 3:

STEP 3:

Outside the mouth, assemble two spring, screw and pivot combinations. To guarantee pivot will slide onto archwire, do not over tighten screw at this point. Place assembled components onto the lower archwire. Insert and ligate archwire, positioning the pivots mesial to the lower first molars. Now, tighten screw as needed.

Outside the mouth, assemble two spring, screw and pivot combinations. To guarantee pivot will slide onto archwire, do not over tighten screw at this point. Place assembled components onto the upper archwire. Insert and ligate archwire, positioning the pivots mesial to the upper first molars. Now, tighten screw as needed.

Using a hemostat, stretch spring eyelet onto the upper pivot and secure in place with a screw.

Using a hemostat, stretch spring eyelet onto the lower pivot and secure in place with a screw.

F or use in a passive position, simply break off the tip of the hybrid screw, allowing the pivot to move freely along archwire. For use in the active position, simply insert the screw into pivot and tighten to lock into desired position on the archwire.

Will actively lock on archwires larger than .016 x .022

TIPS At subsequent visits, reposition the pivots or change from 10mm springs to 7mm springs for further activation. In the resting jaw position the spring should have less than 2mm of activation.


Example of Laboratory Options

(upper view)

(lower view) (laboratory option)

There are multiple options to use CS-2000速 in Class II & III along with upper and lower fixed appliances. See CS-2000 educational animations at www.dynaflex.com

Use your QR code reader to view or download a prescription or visit www.dynaflex.com.

Results Matter The CS-2000速 Appliance has been used successfully for over 8 years with thousands of patients seeing remarkable results with little to no compliance necessary. Case photos compliments of Dr. Michael Williams of Gulfport, MS

BEFORE

Class II Treated Case BEFORE

AFTER

PROGRESS

AFTER

Class III Treated Case


“The Dynaflex® CS-2000® appliance has greatly improved our abilities to correct Class III malocclusions. We love how easy it is to place and it is as durable a product as I have used for inter-arch correction. The design is excellent and we have improved our overall results while shortening our treatment time using this product. We do really enjoy using these appliances, and they have not only held-up well, they really work.”

– Dr. Anthony Harwell and Dr. Tony Harwell CS-2000® 5-Patient Kit

Pivot Wire inserted into pivot

Screw 10 mm 7 mm Niti Springs

Sterilizable Allen Pencil (optional)

Part #

To Order: 866.346.5665 or www.dynaflex.com

Description

Price

349.00

#3800-5E 5-Patient Kit - 10mm

$

#3815-7E 5-Patient Kit - 7mm

$

10-Patient Kit - 10mm

$

#3809 CS-2000® Niti Spring 10mm

$

#3811 CS-2000® Niti Spring 7mm

$

includes 10 (10mm) CS-2000 Niti Springs, 20 slotted pivots, 20 hybrid screws & an Allen Pencil includes 10 (7mm) CS-2000 Niti Springs, 20 slotted pivots, 20 hybrid screws & an Allen Pencil

#3800-10E

includes 20 (10mm) CS-2000 Niti Springs, 40 slotted pivots, 40 hybrid screws & an Allen Pencil

#3810-E

Pivot with Slotted Base .022 x .025

#3815-5E

Screw for pivot

#3823-E

Allen pencil (sterilizable)

349.00 649.00

17.50 each 17.50 each $ 10.00 each $ 1.95 each $ 28.50


P.O. Box 99 St. Ann, MO 63074 866-346-5665

“The CS-2000® is by far the most efficient and patient-friendly appliance on the market for dental correction of Class III malocclusions. For my nonsurgical adolescent and adult class III patients, you could say “it’s the only game in town.”

Quickly Becoming The

Dr. Andy Hayes, DDS, MSD

MOST ADVANCED & EASIEST TO USE

St. Louis Orthodontic Group

Class II & Class III Corrector Available Today! “The introduction of the CS-2000® springs has been an extraordinary addition to our practice. Patient compliance with elastics is no longer an issue!” Dr. Mel Collazo DDS, MS, PA Collazo Orthodontics • Little Rock, Arkansas

PROVEN RESULTS! BEFORE

PROGRESS

AFTER

Case photos compliments of Dr. Andy Hayes of St. Louis, MO

031114 © 2014 DynaFlex® , St. Louis, MO 63074. Printed in U.S.A. All rights reserved. It is a violation of copyright law to reproduce all or part of this material, including photography, without the permission of DynaFlex®. CS-2000® patent pending. Spring Patent 6719557


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.