WOYR2.E51383 - Switches, Appliance and Special Use - Component
Seite 1 von 3
WOYR2.E51383 Switches, Appliance and Special Use - Component Enhanced searching capability for this category can be found in UL's iQ Family of Databases (iq.ul.com). Page Bottom
Switches, Appliance and Special Use - Component See General Information for Switches, Appliance and Special Use - Component EAO AG
E51383
TANNWALDSTRASSE 88 4601 OLTEN, SWITZERLAND Investigated to ANSI/UL 1054
Cat. No.
Amps
Volts
Hz
Load
Endurance
Temp C
POL/ THR
Per Pole/ Circuit Code
SPCOA
01,14,41 w/suff. 5
250
60
GP
6K
65
M-M
-/-
2
0.4
125
DC
-
6K
0.2
250
DC
-
6K
10
250
60
GP
6K
65
M/2
-/-
2
0.4
125
DC
-
6K
0.2
250
DC
-
6K
0.6
125
DC
-
6K
0.4
250
DC
-
6K
1/M
-/-
2, Note 1
65
M/1
PP/-
2, 6 (16)
6K
85
M/1
PP/-
2, 6 (16)
50
1/M
-/-
2, Note 1
02, 03 w/suff.
11,15,21,30, 31-1##, 31-2##, 31-33#, 31-35#, 31-39#, 31/51, 32 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
65
22 followed by 6 suffixes numbers, f/b 65, with or without letters 10
250
60
GP
6K
22 followed by 6 suffixes numbers, with or without letters 10
250
60
GP
31-30, 31-31, 31-32, 31-36, 31-37, 31-38 6
250
60
GP
6K
5
75
DC
-
6K
0.5
250
DC
-
6K
51-12#, 51-13#, 51-14#, 51-15#, 51-19#, 51-23#, 51-25#, 51-261, 51-262, 51-263, 51-264, 51-271, 51-272, 51273, 51-274, 51-281, 51-282, 51-283, 51-284, 51-29#, 51-33#, 51-35# 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
65
1/M
-/-
2, Note 1
51-16#, 51-17#, 51-18# 51-265, 51-275, 51-285, 51-30#, 51-31#, 51-32#, 51-36#, 51-37#, 51-38# 6
250
60
GP
6K
5
75
DC
-
6K
0.5
250
DC
-
6K
50
1/M
-/-
2, Note 1
mhtml:file://C:\Users\belinda.graf\Desktop\WOYR2_E51383 - Switches, Appliance a... 17.10.2012
WOYR2.E51383 - Switches, Appliance and Special Use - Component
Seite 2 von 3
51-39#, 51-4##, 51-7## 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
65
1/M
-/-
2, Note 1
50
M/2
PP/-
-
65
1/M
-/-
2, Note 1
50
1/M
-/-
2, Note 1
51.971.022, 51.973.022, 71.671.026, 51.972.022, 31.970.022, 71.672.026 6
250
-
GP
6K
0.5
250
DC
-
6K
5
75
DC
-
6K
52-1##, 52-2##, 52-7## 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
52-571, -572, -573, -574 6
250
60
GP
6K
5
75
DC
-
6K
0.5
250
DC
-
6K
61 f/b by 82, 84, 85, 86 or 87 f/b suffixes for use with actuator assembly Cat. No. 61 f/b by 1-9, f/b 1-9, f/b by 1-8, f/b by 0-8 f/b 0 or 8, f/b by 2, 5, D, K or X 6
250
60
GP
6K
3
277
60
R
6K
5
250
60
GP
6K
60
M/1
PP/-
-
-/-
2
ACCESSORY INDICATOR - Cat. No. 61-00, f/b 0 through 5, f/b 0 or 9, f/b .0 or .02 0.125
48
DC
-
-
60
-
E may be f/b by CO, f/b 16, may be f/b 0, 1 or 2, f/b by 1, 2 or 3 f/b 0, 1 or 2, f/b by 0 or 5, f/b by 2,4,5 or 7 5
250
60
GP
6K
65
M/M
-/-
2
INDICATOR SERIES 01, followed by -030, -031, -741, -742, -040, -041, -701, -702, -050, -051, -703 or -704, followed by .002, .005 or .006 -
-
-
GP
-
65
-
-/-
-
-/-
-
INDICATOR SERIES 11, followed by -030, -031 or -742, followed by .805 or .806 -
-
-
GP
-
65
-
INDICATOR SERIES 14, followed by -030, -031, -741, -742, -040 or -041 followed by .002, .005 or .006 -
-
-
GP
-
65
-
-/-
-
INDICATOR SERIES 31, followed by -030, -031, -040, -041, -701, -702, -050, -051, -703 or -704, followed by .002, .005 or .006 -
-
-
GP
-
65
-
-/-
-
INDICATOR SERIES 51, followed by -030, -031, -032, -741, -742, -040, -041, -042, -701, -702, -050, -051, -052, 703 or -704, followed by .002, .005, .006, .002F, .005F or .006F -
-
-
GP
-
65
-
-/-
-
Switch Cat. No. 618, f/b 1, 2, 4 or 5, f/b 0-9, f/b by 0-2, f/b 2, 5 or 8 for use with actuator assembly Cat. No. 61 f/b by 1-9, f/b 1-9, f/b by 1-8, f/b by 0-8 f/b 0 or 8, f/b by 2, 5, D, K or X 6
250
60
GP
6K
3
277
60
R
6K
50
M/1
PP/-
-
# - 0-9, A-Z. Note 1 - When provided with an integral fuse holder, a Listed miniature fuse shall be employed and not exceed 6.3A. Note 2 - INDICATOR SERIES 61-00 the switch type 61 may used as terminal. After assembling of the indicator to the switch type 61, no further switching is possible.
Marking: Company name, catalog, model or part number, electrical ratings and the Recognized Component Mark, smallest unit container in which the product is packaged.
on the product or on the
mhtml:file://C:\Users\belinda.graf\Desktop\WOYR2_E51383 - Switches, Appliance a... 17.10.2012
WOYR2.E51383 - Switches, Appliance and Special Use - Component
Seite 3 von 3
Last Updated on 2011-09-26 Questions?
Print this page
Terms of Use
Page Top
Š 2012 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Š 2012 UL LLC".
mhtml:file://C:\Users\belinda.graf\Desktop\WOYR2_E51383 - Switches, Appliance a... 17.10.2012
WOYR8.E51383 - Switches, Appliance and Special Use Certified for Canada - Com... Seite 1 von 2
WOYR8.E51383 Switches, Appliance and Special Use Certified for Canada - Component Enhanced searching capability for this category can be found in UL's iQ Family of Databases (iq.ul.com). Page Bottom
Switches, Appliance and Special Use Certified for Canada - Component See General Information for Switches, Appliance and Special Use Certified for Canada - Component EAO AG
E51383
TANNWALDSTRASSE 88 4601 OLTEN, SWITZERLAND Cat. No.
Amps
Volts
Hz
Load
Endurance
Temp C
POL/ THR
Per Pole/ Circuit Code
SPCOA
01,14,41 w/suff. 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
10
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
0.6
125
DC
-
6K
0.4
250
DC
-
6K
65
M-M
-/-
2
65
M/2
-/-
2
65
1/M
-/-
2, Note 1
50
1/M
-/-
2, Note 1
02, 03 w/suff.
11,15,21,30, 31-1##, 31-2##, 31-33#, 31-35#, 31-39#, 31/51, 32 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
31-30, 31-31, 31-32, 31-36, 31-37, 31-38 6
250
60
GP
6K
5
75
DC
-
6K
0.5
250
DC
-
6K
51-12#, 51-13#, 51-14#, 51-15#, 51-19#, 51-23#, 51-25#, 51-261, 51-262, 51-263, 51-264, 51-271, 51-272, 51273, 51-274, 51-281, 51-282, 51-283, 51-284, 51-29#, 51-33#, 51-35# 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
65
1/M
-/-
2, Note 1
51-16#, 51-17#, 51-18# 51-265, 51-275, 51-285, 51-30#, 51-31#, 51-32#, 51-36#, 51-37#, 51-38# 6
250
60
GP
6K
5
75
DC
-
6K
0.5
250
DC
-
6K
50
1/M
-/-
2, Note 1
65
1/M
-/-
2, Note 1
65
1/M
-/-
2, Note 1
51-39#, 51-4##, 51-7## 5
250
60
GP
6K
0.4
125
DC
-
6K
0.2
250
DC
-
6K
60
GP
6K
52-1##, 52-2##, 52-7## 5
250
mhtml:file://C:\Users\belinda.graf\Desktop\WOYR8_E51383 - Switches, Appliance a... 17.10.2012
WOYR8.E51383 - Switches, Appliance and Special Use Certified for Canada - Com... Seite 2 von 2
0.4
125
DC
-
6K
0.2
250
DC
-
6K
52-571, -572, -573, -574 6
250
60
GP
6K
5
75
DC
-
6K
0.5
250
DC
-
6K
50
1/M
-/-
2, Note 1
E may be f/b by CO, f/b 16, may be f/b 0, 1 or 2, f/b by 1, 2 or 3 f/b 0, 1 or 2, f/b by 0 or 5, f/b by 2,4,5 or 7 5
250
60
GP
6K
65
M/M
-/-
2
# - 0-9, A-Z. Note 1 - When provided with an integral fuse holder, a Listed miniature fuse shall be employed and not exceed 6.3A. Note 2 - INDICATOR SERIES 61-00 the switch type 61 may used as terminal. After assembling of the indicator to the switch type 61, no further switching is possible. * - CTI PLC is marked on individual board.
Marking: Markings on the switch body consist of at least items (a) and (b) or (c) as noted below (other markings shall be on the smallest shipping package): (a) Manufacturer's identifier (such as name or trademark, as described in the UL file) (b) Electrical ratings (c) Catalog or model number (or equivalent) (d) Factory code (as described in the UL Report, if more than one location)
(e) Recognized Component Mark for Canada,
Last Updated on 2009-07-29 Questions?
Print this page
Terms of Use
Page Top
Š 2012 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Š 2012 UL LLC".