Electrak Intersoc modular desk power system Intersoc is a complete modular desk power system designed to meet the increasing power and communication needs of the modern workplace. Available in standard and clean earth versions, its unique design features enable rapid configuration and workstation relocation.
®
INTERSOC UNDER-DESK Intersoc modules have been designed with speed of installation and flexibility in mind. Modular configuration enables thousands of different combinations to be made. Simple push-fit connection means that, if expansion is required, modules can simply be disconnected and additional modules inserted. The range can be factory configured or assembled on site. And with simple screw holes in the feed units and end caps, Intersoc can be easily installed on to any fixing surface.
®
INTERSOC DESKTOP Intersoc desktop units offer all you will ever need in a sleek aluminium finish. With a range of mounting options to complement furniture arrangement, the range provides a quality solution for easy access to desktop power and data.
32
032_033P_D2010.indd 32
09/06/2010 09:48
QUALITY CONNECTIONS All sockets push-ďŹ t together with busbar interconnection that needs no wiring.
INTERNATIONAL SOCKETS BRITISH STANDARD Cyprus, Hong Kong, Ireland, Kuwait, Malaysia, Oman, Qatar, Singapore, UAE, UK SCHUKO Austria, Finland, Germany, Greece, Holland, Hungary, Iceland, Latvia, Luxembourg, Norway, Poland, Portugal, Romania, Russia, Sweden, Turkey
15 A ROUND PIN India, South Africa, Sri Lanka 5 A ROUND PIN India, Sri Lanka 15 A & 20 A NORTH AFRICA USA, Brazil, Canada, Philippines, Saudi Arabia, Thailand
CHINESE & AUSTRALIAN Argentina, Australia, China
33
032_033P_D2010.indd 33
09/06/2010 09:49
034_036P_D2010 v3.qxd
4/6/10
13:40
Page 34
NEW
Intersoc® desk modules under-desk modular system
- - /- - - /- IAB340A
IAB301A
Dimensions and technical information (p. 40-42) The Intersoc 32 A under-desk range is a complete modular power system. All modules are busbar interconnected with no terminals and simply push-fit and lock together enabling rapid configuration and easy workstation reconfiguration The Intersoc modular system meets the requirements of BS 7671 : 2008, and relevant components are available in both standard and low noise / clean earth versions. Individually fused sockets are also available to meet the requirements of BS 6396 : 2008
Pre-wired Intersoc feed modules
Pack
Cat. Nos.
1 1 1 1
IAB002A IAB003A IAB004A IAB005A
1 1 1 1 1 1 1 1
IAB311A IAB312A IAB315A IAB316A IAB340A IAB341A IAB344A IAB345A
3 m unfused metal tap-off DP1332 5 m unfused metal tap-off DP1532 3 m 13 A fused 543·7 metal tap-off DP1327 5 m 13 A fused 543·7 metal tap-off DP1527 3 m unfused VO nylon tap-off DV1332 5 m unfused VO nylon tap-off DV1532 3 m 13 A fused 543·7 VO nylon tap-off DV1327 5 m 13 A fused 543·7 VO nylon tap-off DV1527
1 1 1 1 1 1 1 1
IAC311A IAC312A IAC315A IAC316A IAC340A IAC341A IAC344A IAC345A
3 m unfused metal tap-off JP2332 5 m unfused metal tap-off JP2532 3 m 13 A fused 543·7 metal tap-off JP2327 5 m 13 A fused 543·7 metal tap-off JP2527 3 m unfused VO nylon tap-off JV2332 5 m unfused VO nylon tap-off JV2532 3 m 13 A fused 543·7 VO nylon tap-off JV2327 5 m 13 A fused 543·7 VO nylon tap-off JV2527
Pack
Cat. Nos.
BS 1363 13 A fused plug 13 A fused plug with 2 m 1·5 mm2 cable 13 A fused plug with 3 m 1·5 mm2 cable 13 A fused plug with 4 m 1·5 mm2 cable 13 A fused plug with 5 m 1·5 mm2 cable Standard earth tap-offs (E24)
Low noise / clean earth tap-offs (E25)
Intersoc feed modules Standard earth 1 1 1 1 1 1
IAB201A IAB201B IAB201C IAB201D IAB301A IAB301E
Rewirable feed module (for cable) Feed module with male GST connector Feed module with male ST connector Feed module with 20 A Neutrik connector 32 A rewirable feed module (for flexible conduit) Feed module with 32 A Neutrik connector
1 1 1 1 1 1
IAC201A IAC201B IAC201C IAC201D IAC301A IAC301E
Rewirable feed module (for cable) Feed module with male GST connector Feed module with male ST connector Feed module with 20 A Neutrik connector 32 A rewirable feed module (for flexible conduit) Feed module with 32 A Neutrik connector
Low noise / clean earth
34
Pre-wired connectors BS 1363 13 A fused plug pre-wired to GST 18/3 connector
1 1 1 1
IAB002B IAB003B IAB004B IAB005B
13 A fused plug with 2 m 1·5 mm2 cable 13 A fused plug with 3 m 1·5 mm2 cable 13 A fused plug with 4 m 1·5 mm2 cable 13 A fused plug with 5 m 1·5 mm2 cable BS 1363 13 A fused plug pre-wired to ST 18/3 connector
1 1 1 1
IAB002C IAB003C IAB004C IAB005C
13 A fused plug with 2 m 1·5 mm2 cable 13 A fused plug with 3 m 1·5 mm2 cable 13 A fused plug with 4 m 1·5 mm2 cable 13 A fused plug with 5 m 1·5 mm2 cable BS 1363 13 A fused plug pre-wired to 20 A Neutrik connector
1 1 1 1
IAB002D IAB003D IAB004D IAB005D
13 A fused plug with 2 m 1·5 mm2 cable 13 A fused plug with 3 m 1·5 mm2 cable 13 A fused plug with 4 m 1·5 mm2 cable 13 A fused plug with 5 m 1·5 mm2 cable Standard earth tap-offs (E24) pre-wired to 32 A Neutrik connector
1 1 1 1 1 1 1 1
IAB311E IAB312E IAB315E IAB316E IAB340E IAB341E IAB344E IAB345E
3 m unfused metal tap-off DP1332 5 m unfused metal tap-off DP1532 3 m 13 A fused 543·7 metal tap-off DP1327 5 m 13 A fused 543·7 metal tap-off DP1527 3 m unfused VO nylon tap-off DV1332 5 m unfused VO nylon tap-off DV1532 3 m 13 A fused 543·7 VO nylon tap-off DV1327 5 m 13 A fused 543·7 VO nylon tap-off DV1527 Low noise / clean earth tap-offs (E25) prewired to 32 A Neutrik connector
1 1 1 1 1 1 1 1
IAC311E IAC312E IAC315E IAC316E IAC340E IAC341E IAC344E IAC345E
3 m unfused metal tap-off JP2332 5 m unfused metal tap-off JP2532 3 m 13 A fused 543·7 metal tap-off JP2327 5 m 13 A fused 543·7 metal tap-off JP2527 3 m unfused VO nylon tap-off JV2332 5 m unfused VO nylon tap-off JV2532 3 m 13A fused 543·7 VO nylon tap-off JV2327 5 m 13A fused 543·7 VO nylon tap-off JV2527
034_036P_D2010 v3.qxd
4/6/10
13:41
Page 35
Intersoc® desk modules
NEW
under-desk modular system (continued)
IAB401A
IAB420A
IAC502A
IAB403A
IAB502B
IAC504A
IAB408A
IAB504E
IAC504D
Dimensions and technical information (p. 40-42) The Intersoc 32 A under-desk range is a complete modular power system. All modules are busbar interconnected with no terminals and simply push-fit and lock together enabling rapid configuration and easy workstation reconfiguration The Intersoc modular system meets the requirements of BS 7671 : 2008, and relevant components are available in both standard and low noise / clean earth versions. Individually fused sockets are also available to meet the requirements of BS 6396 : 2008 Pack
1 1 1 1 1 1 1 1 1 1 1 1 1
Cat. Nos.
IAB401A IAB402A IAB403A IAB408A IAB405A IAB410A IAB420A IAB430A IAB440A IAB450A IAB460A IAB470A IAB404A
Protection and switching modules Suitable for standard and low noise / clean earth systems With fuse With fuse and sw/neon With fuse and neon With neon With 30 mA RCD With 6 A MCB With 16 A MCB With 20 A MCB With 32 A MCB With 16 A RCBO With 20 A RCBO With 32 A RCBO 32 A max. single isolation module
Socket modules – standard (black) 2 gang unfused 1 1 1
IAB502A IAB502B IAB502C
90° angled sockets 45° angled sockets 135° angled sockets 2 gang individually fused
1 1 1 1 1 1
IAB532A IAB532B IAB532C IAB552A IAB552B IAB552C
1 1 1 1 1
IAB504A IAB504B IAB504C IAB504D IAB504E
3·15 A – 90° angled sockets 3·15 A – 45° angled sockets 3·15 A – 135° angled sockets 5 A – 90° angled sockets 5 A – 45° angled sockets 5 A – 135° angled sockets 4 gang unfused
Socket modules – low noise / clean earth (green)
Pack
Cat. Nos.
1 1 1
IAC502A IAC502B IAC502C
90° angled sockets 45° angled sockets 135° angled sockets
1 1 1 1 1 1
IAC532A IAC532B IAC532C IAC552A IAC552B IAC552C
3·15 A – 90° angled sockets 3·15 A – 45° angled sockets 3·15 A – 135° angled sockets 5 A – 90° angled sockets 5 A – 45° angled sockets 5 A – 135° angled sockets
1 1 1 1 1
IAC504A IAC504B IAC504C IAC504D IAC504E
90° angled sockets 45° angled sockets 135° angled sockets 45°/45°/135°/135° angled sockets 45°/90°/90°/135° angled sockets
1 1 1 1 1 1 1 1 1 1
IAC534A IAC534B IAC534C IAC534D IAC534E IAC554A IAC554B IAC554C IAC554D IAC554E
2 gang unfused
2 gang individually fused
4 gang unfused
4 gang individually fused 3·15 A – 90° angled sockets 3·15 A – 45° angled sockets 3·15 A – 135° angled sockets 3·15 A – 45°/45°/135°/135° angled sockets 3·15 A – 45°/90°/90°/135° angled sockets 5 A – 90° angled sockets 5 A – 45° angled sockets 5 A – 135° angled sockets 5 A – 45°/45°/135°/135° angled sockets 5 A – 45°/90°/90°/135° angled sockets
90° angled sockets 45° angled sockets 135° angled sockets 45°/45°/135°/135° angled sockets 45°/90°/90°/135° angled sockets 4 gang individually fused
1 1 1 1 1 1 1 1 1 1
IAB534A IAB534B IAB534C IAB534D IAB534E IAB554A IAB554B IAB554C IAB554D IAB554E
3·15 A – 90° angled sockets 3·15 A – 45° angled sockets 3·15 A – 135° angled sockets 3·15 A – 45°/45°/135°/135° angled sockets 3·15 A – 45°/90°/90°/135° angled sockets 5 A – 90° angled sockets 5 A – 45° angled sockets 5 A – 135° angled sockets 5 A – 45°/45°/135°/135° angled sockets 5 A – 45°/90°/90°/135° angled sockets
35
034_036P_D2010 v3.qxd
4/6/10
13:41
Page 36
Intersoc® desk modules
NEW
under-desk modular system (continued)
IAZ001A
IAB603A
Dimensions and technical information (p. 40-42) The Intersoc 32 A under-desk range is a complete modular power system. All modules are busbar interconnected with no terminals and simply push-fit and lock together enabling rapid configuration and easy workstation reconfiguration A wide range of interconnection solutions are available with various cabling types. When 16 A cabling interconnection is used with 32 A under-desk solutions, suitable de-rating protection devices must be incorporated to protect the cables Pack
Cat. Nos.
1 1 1 1
IAB600A IAB600B IAB600C IAB600D
Interconnection – power out (male)
Cat. Nos
1 1 1 1 1 1 1
IAB603B IAB605B IAB610B IAB620B IAB630B IAB640B IAB650B
0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length
1 1 1 1 1 1 1
IAB603C IAB605C IAB610C IAB620C IAB630C IAB640C IAB650C
0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length
1 1 1 1 1 1 1
IAB603D IAB605D IAB610D IAB620D IAB630D IAB640D IAB650D
0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length
1 1 1 1 1 1 1
IAB603BB IAB605BB IAB610BB IAB620BB IAB630BB IAB640BB IAB650BB
0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length
1 1 1 1 1 1 1
IAB603CC IAB605CC IAB610CC IAB620CC IAB630CC IAB640CC IAB650CC
16 A male Intersoc to female GST
16 A components Rewirable male interconnect Male interconnect with female GST connector Male interconnect with female ST connector Male interconnect with 20A Neutrik connector 32 A components 1
IAB700A
Rewirable male interconnect
Interconnection – power in (female) 16 A components 1 1 1 1
IAB201A IAB660B IAB660C IAB660D
1
IAB301A
Rewirable female interconnect Female interconnect with male GST connector Female interconnect with male ST connector Female interconnect with 20A Neutrik connector
16 A male Intersoc to female ST
32 A components Rewirable female interconnect
Pre-wired interconnection 16 A male to female Intersoc 2P + E 1 1 1 1 1 1 1
IAB603A IAB605A IAB610A IAB620A IAB630A IAB640A IAB650A
1 1 1 1 1 1 1
IAB703A IAB705A IAB710A IAB720A IAB730A IAB740A IAB750A
0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length 32 A male to female Intersoc 2P + E 0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length
Pre-wired interconnection (continued)
Pack
16 A male Intersoc to 20 A Neutrik connector
16 A male to female GST connection leads
16 A male to female ST connection leads 0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length 20 A Neutrik to Neutrik connection leads 1 1 1 1 1 1 1
IAB603DD IAB605DD IAB610DD IAB620DD IAB630DD IAB640DD IAB650DD
To be used as part of a 16 A system 0·3 m length 0·5 m length 1 m length 2 m length 3 m length 4 m length 5 m length
End cap 36
1
IAZ001A
Blank end cap
037_039P_D2010 v3.qxd
4/6/10
16:07
Page 37
Intersoc® desk modules 16 A popular starter modules
TACB032B
TAAA052B
TADB054B
TACA034B
Dimensions and technical information (p. 40-42) Mains connection to these modules will be via an integral GST 18/3 connector or rewirable terminals. Starter modules can be used independently by adding a blank end cap (Cat. No. IAZ001A) or extended by adding additional socket modules. Can also be linked to other modules via flexible cable The last module in any run or combination must have a blank end cap to cover the open end Pack
Cat. Nos.
Rewirable feed and open end
Pack
Cat. Nos.
2 gang – modules without master switch or fuse
2 gang – modules without master switch or fuse 1 1 1 1
TAAA032A TAAA032B TAAA052A TAAA052B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
1 1 1 1
TAAB032A TAAB032B TAAB052A TAAB052B
TAAA034A TAAA034B TAAA054A TAAA054B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
1 1 1 1
TACA032A TACA032B TACA052A TACA052B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
1 1 1 1
TAAB034A TAAB034B TAAB054A TAAB054B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
1 1 1 1
TACB032A TACB032B TACB052A TACB052B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
2 gang – modules with master switch / neon
2 gang – modules with master switch / neon
4 gang – modules with master switch / neon
4 gang – modules with master switch / neon 1 1 1 1
TACA034A TACA034B TACA054A TACA054B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
1 1 1 1
TACB034A TACB034B TACB054A TACB054B
TADA032A TADA032B TADA052A TADA052B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
1 1 1 1
TADB032A TADB032B TADB052A TADB052B
TADA034A TADA034B TADA054A TADA054B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A 4 gang – modules with master 13 A fuse and switch / neon
4 gang – modules with master 13 A fuse and switch / neon 1 1 1 1
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A 2 gang – modules with master 13 A fuse and switch / neon
2 gang – modules with master 13 A fuse and switch / neon 1 1 1 1
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A 4 gang – modules without master switch or fuse
4 gang – modules without master switch or fuse 1 1 1 1
GST 18/3 feed and open end
1 1 1 1
TADB034A TADB034B TADB054A TADB054B
90º angled sockets individually fused at 3·15 A 45º angled sockets individually fused at 3·15 A 90º angled sockets individually fused at 5 A 45º angled sockets individually fused at 5 A
37
037_039P_D2010 v3.qxd
4/6/10
14:07
Page 38
Intersoc® desk modules 16 A popular starter modules – add-on options
Mains power lead
4 socket in-feed module (see p. 37)
IAB002B
Interlink GST connectors and flexible lead IAB603BB
TACB034B
2 socket module IAB532B
- -/---- -/ Power out interconnect with GST connector IAB600B
IAB504B
IAB502B
Power in interconnect with GST connector IAB660B
IAB600A
IAB534B
Blank end cap IAZ001A
IAB201A
Dimensions and technical information (p. 40-42) Mains connection to these modules will be via an integral GST 18/3 connector or rewirable terminals. Starter modules can be used independently by adding a blank end cap (IAZ001A) or extended by adding additional socket modules. Modules can also be interlinked via flexible cable The last module in any run or combination must have a blank end cap to cover the open end Pack
Cat. Nos.
1
IAB002B
1
IAB003B
1
IAB005B
Mains power leads
Pack
Cat. Nos.
1 1
IAZ001A IAB600B
1
IAB660B
1 1
IAB600A IAB201A
1
IAB603BB
1
IAB605BB
4 gang unfused
1
IAB610BB
45º angled sockets 135º angled sockets 90º angled sockets
1
IAB620BB
2 gang individually fused
1
IAB630BB
2 m 13 A fused BS 1363 plug to female GST connector with 1·5 mm2 cable 3 m 13 A fused BS 1363 plug to female GST connector with 1·5 mm2 cable 5 m 13 A fused BS 1363 plug to female GST connector with 1·5 mm2 cable
Additional socket modules 2 gang unfused 1 1 1
IAB502B IAB502C IAB502A
1 1 1
IAB504B IAB504C IAB504A
45º angled sockets 135º angled sockets 90º angled sockets
1 1 1
IAB532B IAB532C IAB532A
3·15 A – 45º angled sockets 3·15 A – 135º angled sockets 3·15 A – 90º angled sockets
1 1 1
IAB534B IAB534C IAB534A
3·15 A – 45º angled sockets 3·15 A – 135º angled sockets 3·15 A – 90º angled sockets
4 gang individually fused
38
End caps / interconnection Blank end cap Power out - male interconnect with female GST connector Power in - female interconnect with male GST connector Power out - male interconnect rewirable 16 A rewirable feed module (please note : also used as female interconnect rewirable power in) 0·3 m 16 A male to female GST connectors with 1·5 mm2 cable 0·5 m 16 A male to female GST connectors with 1·5 mm2 cable 1 m 16 A male to female GST connectors with 1·5 mm2 cable 2 m 16 A male to female GST connectors with 1·5 mm2 cable 3m 16 A male to female GST connectors with 1·5 mm2 cable
037_039P_D2010 v3.qxd
4/6/10
14:17
Page 39
Intersoc® HDU and VDU modules horizontal and vertical desktop units
HA1952AC Horizontal on-desk unit VA1452AC Vertical on-desk unit
Dimensions and technical information (p. 40-41) Desktop units offer power and data solutions with a range of mounting options to compliment your furniture arrangements All units are housed in an aluminium extrusion and are available in either horizontal or vertical orientation Any combination of socket outlets and other services can be integrated into the aluminium housing to suit individual customer requirements including switching of individual sockets Pack
Cat. Nos.
16 A horizontal desktop units (HDU)
Pack
Cat. Nos.
All units are supplied with sockets angled at 90º Where data is offered, units come complete with 3 m data leads & RJ45 plugs
All units are supplied with sockets angled at 45º Where data is offered, units come complete with 3 m data leads & RJ45 plugs
1 m power lead – BS 1363 13 A fused plug 1 1
HA1952AA HA1952AB
1
HA1952AC
1 1
HA1953AA HA1954AA
1 1
HA3952AA HA3952AB
1
HA3952AC
1 1
HA3953AA HA3954AA
1 1
HB1932AA HB1932AB
1
HB1932AC
1 1
HB1933AA HB1934AA
2 sockets individually fused at 5 A 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets 3 sockets individually fused at 5 A 4 sockets individually fused at 5 A
1 m power lead – BS 1363 13 A fused plug 1 1
VA1452AA VA1452AB
1
VA1452AC
1 1
VA1453AA VA1454AA
1 1
VA3452AA VA3452AB
1
VA3452AC
1 1
VA3453AA VA3454AA
1 1
VB1432AA VB1432AB
1
VB1432AC
1 1
VB1433AA VB1434AA
3 m power lead – BS 1363 13 A fused plug 2 sockets individually fused at 5 A 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets 3 sockets individually fused at 5 A 4 sockets individually fused at 5 A
H001
Horizontal desktop unit fixing clamp
10
H002
Desktop adhesive strip
2 sockets individually fused at 5 A 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets 3 sockets individually fused at 5 A 4 sockets individually fused at 5 A 1 m power lead – male GST connector
Fixings 2
2 sockets individually fused at 5 A 2 sockets individually fused at 5 A + 1 x RJ45 CAT 5e data outlet 2 sockets individually fused at 5 A + 2 x RJ45 CAT 5e data outlets 3 sockets individually fused at 5 A 4 sockets individually fused at 5 A 3 m power lead – BS 1363 13 A fused plug
1 m power lead – male GST connector 2 sockets individually fused at 3·15 A 2 sockets individually fused at 3·15 A + 1 x RJ45 CAT 5e data outlet 2 sockets individually fused at 3·15 A + 2 x RJ45 CAT 5e data outlets 3 sockets individually fused at 3·15 A 4 sockets individually fused at 3·15 A
16 A vertical desktop units (VDU)
2 sockets individually fused at 3·15 A 2 sockets individually fused at 3·15 A + 1 x RJ45 CAT 5e data outlet 2 sockets individually fused at 3·15 A + 2 x RJ45 CAT 5e data outlets 3 sockets individually fused at 3·15 A 4 sockets individually fused at 3·15 A Fixings
2
V001
Vertical desktop unit fixing clamp
Any combination of socket and service outlets can be configured on request (eg USB, IBM, Co-axial, SGVA, RJ45 etc.) Contact us on +44 (0) 845 600 6266 39
040_043P_D2010 v3.qxd
4/6/10
17:26
Page 40
Intersoc® under-desk and desktop modules technical information
■ Under-desk and popular range dimensions (mm) 2 socket in-feed module
Blank end cap
4 socket in-feed module
GST interconnect male
Rewirable interconnect male
60
GST interconnect female
23
411·5
291·5
Rewirable interconnect female
2 socket module
50
4 socket module
67
End view
60
32
60
75
156·5
110·5
MCB, RCD protection module
276·5
Protection module
60
Interconnection Rewirable infeed has 16 mm Ø hole for flexible cable entry cable restraint
60
174·5
77·5
50
115·5
■ Socket outlet orientation Socket outlets are available in a selection of socket angles
45˚
90˚
135˚
Unfused
Individually fused 3·15 A or 5 A IEC fuses
■ Desktop range dimensions (mm) 2 socket individually fused unit
2 socket individually fused and 1 RJ45 unit 293
218
4 socket individually fused unit
2 socket individually fused and 2 RJ45 unit
368
348
Vertical
Horizontal
3 socket individually fused unit
40
293
40
100
All dimensions (mm) are nominal
40
100
040_043P_D2010 v3.qxd
4/6/10
17:40
Page 41
■ Under-desk and popular range testing and accreditation
■ Under-desk and desktop British Standards BS 6396 : 2008 Electrical Systems in Office Furniture and Office Screens BS 7671 : 2008 Requirements for Electrical Installation (IEE Wiring Regulations 17th Edition) Electricity at Work Regulations 1989
Conform to BS 5733 and the relevant parts of BS 1363 part 2 Manufactured within an approved ISO 9001 : 2008 facility Quality assurance certificate No. 10270
Health & Safety Legislation Below is a brief outline of the main criteria within the standards :
Electrical test data Rated current Rated voltage Frequency
BS 6396 : 2008 was published with regard to the use of electrical equipment within general office furniture and screens. This standard sets out in its scope the use and testing of electrical socket outlets and associated wiring when used together with a 13 A BS 1363 fused plug for mains supply and makes provision for the routing of cables through furniture
up to 32 A 250 V ~ 50/60 Hz
Conductor resistance at 20°C
For compliance with this standard, socket outlet configurations 2 or 4 outlets should be individually fused at 5 A and 6 outlets individually fused at 3·15 A
2 socket module 4 socket module
A note on individual socket fusing – BS 6396 Compliance :
1·4 mΩ 2·8 mΩ
The standard requires individual socket fusing (as per the table below) Total number of sockets 2 or 4 sockets 5 or 6 sockets
Volt drop Live and neutral 2 socket module 4 socket module Protection module
2·8 m V/A 5·6 m V/A 4·0 m V/A
BS 7671 : 2008 (17th Edition). The Health and Safety Executive states that installations which conform to the standards laid down in BS 7671 : 2008 are regarded by the HSE as likely to achieve conformity with the relevant parts of the Electricity at Work Regulations 1989
(depending on device)
In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2
2·0 m V/A 29 m V/Am 2·0 m V/A 11 m V/Am
Special note should be taken of regulation 543·7 within BS 7671 : 2008 - Earthing requirements for the installation of equipment having high protective conductor currents Regulation 543·7 has particular importance when there is a requirement for a quantity of information technology equipment being supplied from a final circuit in a location where the sum of their protective currents exceeds 10 mA in normal use. Due to current in the protective conductor arising from the use of IT equipment, there is a requirement to provide mechanically protected 4 mm2 conductor (543·7·1·3(ii)). Intersoc achieves this when wired in accordance with the installation sheets by providing mechanically protected 5 mm2 protective conductors within the product
2·0 m V/A 29 m V/Am 11 m V/Am
Earth fault loop impedance 2 socket module 4 socket module Protection module
2·8 mΩ 5·6 mΩ 4·0 mΩ
Material specification Under desk : Module housing Socket outlets Busbars Other metalwork
(depending on device)
In-feeds : 16 A +1·5 mm2 32 A +4 mm2 Interconnections : 16 A/32 A +1·5 mm2 +4 mm2
Individually fused at 5A 3·15 A
2·0 mΩ 29 mΩ/m 2·0 mΩ 11 mΩ/m
On desk : Module housing Module fascia Socket outlets End caps
2·0 mΩ 29 mΩ/m 11 mΩ/m
VØ flame retardant ABS polycarbonate high conductivity copper C101 phosphor bronze PB102 PB103, brass CZ108 high conductivity copper C101 aluminium VØ flame retardant ABS polycarbonate VØ flame retardant ABS
Mechanical data Number of conductors Busbar conductor cross-sectional area 16 A rewirable in-feed terminal capacity 32 A rewirable in-feed terminal capacity
3 5 mm2 10 mm2 10 mm2
41
040_043P_D2010 v3.qxd
4/6/10
17:46
Page 42
Intersoc® under-desk modules installation and configuration
■ Installation To connect and disconnect Intersoc modules 1. Connection / disconnection to be made by a competent person 2. Before connecting modules ensure they are the correct way up and in line 3. Push modules together one at a time 4. Modules self-lock when fully pushed together 5. To disconnect modules slide green latch to unlock module and pull apart 6. Always end module run with blank end cap or interconnect
Module self-locking latch
Underside of modules shown
To fix modules to surface 1. Insert through all fixing holes no. 8 pozi-pan screw or M4 bolt to required length 2. Tighten screw / bolt down to mounting surface
Slide green latch
Blank end cap
2 socket module
4 socket in-feed module shown, extended to 6 sockets by adding a 2 socket module and closed by a blank end cap
16 A 4 socket in-feed module
■ Product configuration 1. Select the type of distribution system - standard, or low noise / clean earth 2. Select the means of powering the system - cable or power track tap-off 3. Select the type of in-feed module to match the cable capacity - 16 A or 32 A 4. Select the means of protection 5. Select the number of socket modules from the 2 or 4 gang range (individually fused or non-fused) 6. Select the orientation of the sockets (socket angle) 7. Select the interconnection units if required 8. Finish system with the end cap (All modules push fit and lock together on-site or can be factory assembled to customer requirement)
iiiiiil
Floor grommet
llllllllllllllllllllllllll llllllll lllllllllllllll Underfloor power track
42
1
2
l l ll ll l
lllll 32 A in-feed connected to tap-off and left underfloor until required
l l ll
Tap-off
llll l
lllllllllllllllll
lllllll
Raised floor
l l ll l ll ll l
l ll l
l ll l
In-feed and power module push together and lock with cam lock lever
Tap-off and in-feed pulled through floor grommet after testing and when required