YAMA INSURGENTES REFORMA WELL v2 - C&S
Feature L01: Light Exposure and Education Part 1: Ensure Indoor Light Exposure
MODELING REPORT
MODELING REPORT- YAMA INSURGENTES REFORMA
Spatial Daylight Autonomy 200/40%
Score=47.71 % PASS
Summary Floor name
Ground Level
Regularly Occupied Area (sf)
sDA Rendering
Percentage of analysis points >200 lux for > 40% of hours
19,504.7
61.86 % N
Level +2
26,308.3
53.66 % N
Level +3
29,375.7
29.19 % N
Level +4
29,375.7
36.17 % N
Level +5
29,375.7
43.48 % N
Floor name
Level +6
Regularly Occupied Area (sf)
sDA Rendering
Percentage of analysis points >200 lux for > 40% of hours
29,375.7
45.46 %
N
Level +7
29,375.7
45.50 % N
Level +8
29,375.7
46.67 % N
Level +9
29,375.7
47.00 %
N
Level +10
29,375.7
46.91 % N
Level +11
29,375.7
47.10 % N
Level +12
29,375.7
47.38 % N
Floor name
Level +13
Regularly Occupied Area (sf)
sDA Rendering
Percentage of analysis points >200 lux for > 40% of hours
29,375.7
47.35 %
N
Level +14
29,375.7
48.01 % N
Level +15
29,375.7
48.25 % N
Level +16
29,375.7
49.44 %
N
Level +17
29,375.7
50.98 % N
Level +18
29,375.7
52.62 % N
Level +19
29,375.7
55.65 % N
Floor name
Regularly Occupied Area (sf)
Level +20
24,353.1
sDA Rendering
Percentage of analysis points >200 lux for > 40% of hours
50.07 % N N
Level +21
11,732.2
67.81 % N
SIMULATION DETAILS Design:
INSURGENTES REFORMA_WELL sDA
Period:
01/01 -12/31
Occupancy:
8:00 AM – 6:00 PM
Location:
Av de los Insurgentes Sur 64, Juárez, Cuauhtémoc, 06600 Ciudad de México, CDMX, México (19.43° , -99.16°)
North Angle:
27.00°
Sky Type:
Clear
Quality:
High
Details: -MF = 1; (145 sun patches) -ab = 6; -ad = 10000; -lw = 0.0001 Grid Spacing:
2.0 ft
Total Area:
582,181.2 ft2
Illuminance Target:
200 lux
Time Threshold:
40%
Materials:
Glass: SG_COOL LITE ST 120 (20.8% VT), Translucent_Glass_Safety (85% VT) Opaque: Ceiling (80.00% Ref.), Floor (20.00% Ref.), Wall (50.00% Ref.)
Date Created:
05/15/2020 2:40 PM
Simulation Duration (2x acceleration) : Original File Name:
15m 37s INSURGENTES REFORMA_WELL.dae.dae
LightStanza Software Version : 4.16.0 Radiance Version:
5.2
GROUND LEVEL
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
sDA Score= 61.86%
sDA Met= YES
sDA Score= 53.66%
sDA Met= YES
sDA Score= 29.19%
sDA Met= NO
LEVEL +2
Lorem ipsum Lorem ipsum
Lorem ipsum
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
LEVEL +3
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
LEVEL +4
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
sDA Score= 36.17%
sDA Met= NO
LEVEL +5 to +19
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
sDA Score= 43.48 to 55.65%
sDA Met= YES
LEVEL +20
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
sDA Score= 50.07%
sDA Met= YES
LEVEL +21
Scale showing area that gets 200 lux a year for more than 40% of occupied time.
sDA Score= 67.81%
sDA Met= YES