SDSU Faculty House 2018

Page 1

SDSU FACULTY HOUSE

Emily Linehan


Brookings City District South Dakota State University Campus Site

7KH GHVLJQ IRU WKH 6'68 )DFXOW\ +RXVH LV D FRXUW\DUG VFKHPH 7KH WZR FRXUW\DUGV DUH SURJUDPPHG VHSDUDWHO\ RQH IRU WKH HQWUDQFH DQG RQH UHVSRQGLQJ GLUHFWO\ WR WKH 6FREH\ FRXUW\DUG 7KH (DVW DQG :HVW ED\V PLUURU 6FREH\ +DOO¶V IRRWSULQW ZLGWK DV ZHOO DV H[WHQG HQFORVH DQG LPSURYH WKH H[LVWLQJ FRXUW\DUG 7KH EXLOGLQJ KHLJKW DOVR PLPLFV WKH FDPSXV DQG UHVLGHQWLDO DGMDFHQFLHV 7KH FRXUW\DUGV OHDG WR RWKHU EXLOGLQJ SURJUDPV ZLWKLQ WKH PL[HG XVHG VWUXFWXUH 7KH EXLOGLQJ ZLOO DFW DV D KRWHO ZLWK JXHVW VXLWHV DQG KLJK TXDOLW\ ORQJ WHUP VWD\ DFFRPPRGDWLRQV 9LVLWRUV LQFOXGH VWDII VWXGHQWV FDPSXV YLVLWRUV DQG ORFDO FRPPXQLW\ PHPEHUV 7KH EXLOGLQJ DOVR SURYLGHV D QHZ KRPH IRU 6'68¶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

6'68 )$&8/7< +286(

South Dakota Brookings Interstates

(PLO\ /LQHKDQ $5&+ %XLOGLQJ 0HGLD 9,, )DOO 6'68 )DFXOW\ +RXVH %URRNLQJV 6RXWK 'DNRWD


Site Plan Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

00-01


Site Diagrams Vehicular Circulation

Courtyard

Surrounding Buildings

Green Spaces

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

00-02


Exploded Floor Plans Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

00-03


Southeast Perspective Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

00-04


West Section Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

00-05


South Section Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

00-06


Design Charette: exploration of possible site layouts using site context to identify potential building layouts and potential courtyards

Design Charette: exploration of possible building layouts using sketches to find necessary program adjacencies

Predesign and Programming

Design Charette: exploration of iterations based on the themes Tray, Wall, and Frame to establish potential building layouts or patterns TRAY WALL FRAME

Design Charette: further explored iterations of possible building forms resulting in a three level H-like form with multiple courtyards

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

01-01


ob ey

Level Three

Programming Sc

ob ey

5.57%

Assembly: 9,370 SF

2.27%

Business: 1,450 SF

Conference Center, Faculty Club Lounge, Restaurant, Commercial Kitchen Offices, Classroom, Teaching Kitchen

17.55% Circulation: 13,715 SF

Halls, Stair Cores, Elevators

34.89% Courtyard: 27064 SF Scobey: 15,567 SF Entrance: 11,497 SF

Level Two

Programming Diagram

Sc

27.73% Residential: 33,702 SF 38 Hotel Units 331 SF-939 SF

11.99% Service: 3,580 SF

Guest Services, Restrooms, Loading, Storage, Mechanical

Total Building Square Footage: 61,817 SF Sc

Ground Level

ob ey

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

01-02


Square Footages Hotel Units: 38 @ 331 SF - 939 SF (23,020 total) Faculty Club Lounge: 1,875 SF Conference Center: 2,450 SF Commercial Kitchen: 2,895 SF Academic Facilities/Offices: 2 @ 150 SF (300 SF total) Academic Facilities/Classroom: 450 SF Academic Facilities/Teaching Kitchen: 700 SF Restrooms: 2 @ 500 SF (1,000 SF total) Scobey Courtyard: 3,264 SF Entrance Courtyard: 3,871 SF Restaurant: 2,150 SF Lobby: 250 SF Storage Rooms: 437.5 SF Mechanical Rooms: 3 @192 SF (576 SF total) Valet Booth: 100 SF 8 Surface parking spaces: 4 ADA Parking Garage: 1st and 2nd Level below grade Passageways: Site Footprint: 165’x230’, 37,950 SF total Allowable Building Footprint: 22,770 SF Total Square Footage: 61,817 SF

SDSU Faculty House- Scobey Courtyard

Space Type: Outdoor Square Footage: 3,264 SF Primary Activity: Recreation Description: Users: Campus guests, long-term stay staff/students Spatial Relationships: President’s House, Alumni Center, 9th Avenue, 9th Street, housing, offices, faculty club lounge, conference center, restaurant Required equipment/furniture: benches, streetlights Other requirements: Paved areas for outdoor lounging Comments:

SDSU Faculty House- Entrance Courtyard

Space Type: Outdoor Square Footage: 1,012 SF (22x46) Primary Activity: Recreation Description: Users: Campus guests, long-term stay staff/students Spatial Relationships: Lobby,faculty lounge, restaurant Required equipment/furniture: benches, streetlights, furniture Other requirements: Paved areas for outdoor lounging Comments:

SDSU Faculty House- Hotel Units

Space Type: Long term Stay hotel Square Footage: 30 @ 331-699 SF & 8 @ 700-939 SF= 33,702 SF total Primary Activity: Sleeping, living, dining, cooking Description: 38 units= 33,702 SF Users: Campus guests, long-term stay staff/students Spatial Relationships: Other hotel units. Elevators, Stairs, President’s House, Alumni Center, 9th Avenue, 9th Street, courtyards Required equipment/furniture: Bed, blankets, pillows, couch, dresser, wardrobe, desk, table, chairs, television, shower, sink, toilet, microwave, oven, refrigerator Other requirements: ADA standards Comments: Studio Suite and Two Bedroom layouts

SDSU Faculty House- Restrooms

Space Type: Personal Square Footage: 2 @ 500 SF Primary Activity: Room for rest and rejuvenation Description: Men’s room and women’s room Users: All users Spatial Relationships: Conference center, club lounge Required equipment/furniture: toilets, sinks, urinals, changing tables, garbages, paper towel holders, hand dryers, coat hooks, stall walls/doors Other requirements: ADA standards Comments:

Programming List

Program Breakdown

SDSU Faculty House- Lobby

Space Type: Entrance Square Footage: 250 SF Primary Activity: Entering Description: 25’x10’, double doors, vestibule first Users: All users Spatial Relationships: Classrooms, Housing Required equipment/furniture: desk, chairs, computer system Other requirements: ADA standards, ramp/sloped entrance Comments:

SDSU Faculty House- Valet Booth

Space Type: Entrance Square Footage: 100 SF Primary Activity: Entering Description: 10’x10’, within vestibule Users: Valet Parkers Spatial Relationships: Lobby, drop off area Required equipment/furniture: desk, chairs, computer system, key locker Other requirements: must comfortable fit three workers Comments:

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

01-03


SDSU Faculty House- Restaurant

SDSU Faculty House- Faculty Club Lounge

SDSU Faculty House- Kitchen

SDSU Faculty House- Conference Center

Space Type: Academic/Public Square Footage: 2,150 SF Primary Activity: Eating, Teaching, Learning Description: Internship based, outside hires if necessary Users: Students, teachers, visitors, public Spatial Relationships: Office, kitchen, bar, courtyard, conference center Required equipment/furniture: tables, chairs, garbage, plates, cups, utensils, napkins, tablecloths Other requirements: table busing station Comments: can be reserved for dinners/catering, must accept HOBO Dough Space Type: Commercial Kitchen, Prep Area, and Dry Storage Square Footage: 2,895 SF Primary Activity: Cooking, meal preparation, services restaurant, caters to conference center Description: Commercial grade Users: Cooks, Staff, Teachers, Students Spatial Relationships: Adjacent to restaurant, Scobey courtyard Required equipment: Walk-in fridges/freezers, ovens, range, dishwasher, three tub sink, pots, pans, utensils, soap, sponges, fans/ventilation Other requirements: Storage space for dry goods Comments:

SDSU Faculty House- Academic Facilities/Offices

Space Type: Academic Square Footage: 2 @ 150 SF each (300 SF total) Primary Activity: Office work Description: Space for employee offices Users: Staff/students Spatial Relationships: President’s House, Alumni Center, 9th Avenue, 9th Street, Club Lounge Required equipment/furniture: desks, chairs, tables, computers, printers Other requirements: Comments:

Space Type: Lounge Square Footage: 1,875 SF Primary Activity: Relaxing, games, television, food, drinks Description: no students allowed Users: SDSU Staff & Faculty, campus guests Spatial Relationships: Commercial kitchen, exit near dumpster, conference center, courtyard, offices Required equipment: Tables, chairs, booths, televisions, couches, pool tables Other requirements: Separate room for reserved dinners up to 50 people Comments: Space Type: Academic/Meeting Square Footage: 2,450 SF Primary Activity: Large meetings, presentations, receptions Description: Large open space Users: SDSU Faculty, Campus Guests Spatial Relationships: Adjacent to club lounge, public restrooms, restaurant, courtyard Required equipment: tables, chairs, stage, microphone, PA system Other requirements: windows for natural light Comments:

SDSU Faculty House- Academic Facilities/Teaching Kitchen: Space Type: Academic/Meeting Square Footage: 700 SF Primary Activity: Class meetings, learning, teaching demonstrations Description: multiple kitchenettes for practicing Users: SDSU students and faculty Spatial Relationships: offices, classroom, courtyard Required equipment: tables, chairs, stage, microphone, PA system Other requirements: windows for natural light Comments:

Programming List Continued

Program Breakdown Continued

SDSU Faculty House- Academic Facility/Classroom Space Type: Academic Square Footage: 450 SF Primary Activity: Teaching, Learning Description: Users: Students, Teachers Spatial Relationships: Offices, teaching kitchen, lobby Required equipment/furniture: tables, chairs, desks, garbage Other requirements: can accommodate 20 students at a time Comments:

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

01-04


Conference Center, Faculty Club Lounge, Restaurant, Commercial Kitchen

OVERVIEW & PROJECT INFORMATION Address: 907 9th Street, Brookings South Dakota Zone: A: Agriculture Applicable Codes: International Building Code 2015 (IBC) Brookings Municipal Code (BMC)

Business

Offices, Classroom, Teaching Kitchen

Circulation

Halls, Stair Cores, Elevators

Occupancy Diagram

Courtyard

Scobey, Entrance

Residential

38 Hotel Units

Service

Sc

Guest Services, Restrooms, Loading, Storage, Mechanical

ob ey

CODE STUDY Overall Building Description: Total Building Area: 61,818 SF Height: 43 Feet Number of Levels: 3 Level 1 Area: 20,605 SF Level 2 Area: 20,605 SF Level 3 Area: 20,605 SF Site Description of Property: 4 feet from sidewalks BMC 26-388

Level Three

Sc

ob ey

Level Two

Building Code Analysis: Occupancy Classification: IBC 303.3 A-2: Assembly IBC 304.1 B: Business IBC 310.3 R-1: Residential Area of Each Occupancy: Assembly: 9,370 SF Conference Center: 2,450 SF Faculty Club Lounge: 1,875 SF Restaurant: 2,150 SF Commercial Kitchen: 2,895 SF Business: 1,450 SF Offices: 300 SF Classroom: 450 SF Teaching Kitchen: 700 SF Residential: 33,702 SF Hotel Units: 33,702 SF Required Occupancy Separation: 1 Hour Type of Construction: Type 2B

Fire Resistive Requirements: IBC Chapter 4: Walls separating dwelling units in the same building, walls separating sleeping units in the same building and walls separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as fire partitions Chapter 7, Table 707.3.10 A, B, R: 2 Hours for fire barrier assemblies or horizontal assemblies between fire areas Occupant Load Calculations: IBC Chapter 10, Table 1004.1.2 1st Level: A-2: 9,370/ 7 net=1,338 people Conference Center: 2,450/ 7= 350 people Faculty Club Lounge: 1,875/ 7=267 people Restaurant: 2,150/ 7= 307 people Commercial Kitchen: 2,895/200 gross= 14 people B: 1891.5/ 100 gross= 18 people Offices: 300/ 100=3 people between 2 offices Classroom: 450/ 20 net= 22 people Teaching Kitchen: 700/ 50 net= 14 people 2nd & 3rd level: R-1: 23,020/ 200 gross= 115 people Hotel Units: 115 people between 38 units Egress Requirements: IBC Chapter 10, 1005.3.1 Exit Width Calculations: Assembly: 914 x .3 = 274.2�=22.85' Business: 18 x .3 = 5.4" Residential: 115 x .3 = 34.5�=2.875' Required Number of Exits: 4 Actual Number of Exits: 12 ,

Fire Areas: Table 412.4.6 2 Hour wall separation

Sc

Ground Level

ob ey

Fire Sprinkler Reasons: IBC Table 504.3 Allowable Height: 55' or three stories above grade Construction Type: Type 2B IBC Table 504.4 Type A-2 must be sprinklered at three stories Basic Allowable Area: IBC Table 506.2 A-2: 28,000 SF B: 69,000 SF R-1: 48,000 SF Actual Building Area A-2: 9,370 SF B: 1,450 SF R-1: 33,702 SF

Building Code Analysis

Assembly

Takeaways: Each occupancy has different requirements according to the IBC. Allowing all residential to be on separate floors than the assembly and business is helpful when dealing with fire regulations.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

02-01


Vertical Circulation

Level Three

Roofs/Canopy

Egress, Circulation, Conveyance

Circulation Diagram

Horizontal Circulation

Level Two

Floors

Stair 3 Stair 1

Ground Level

Elevator Core

Stair 2

Takeaways: Mitsubishi Electric Elevator requires a machine room on the roof. Two of the stair cores have roof access as does the exterior ladder.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

03-01


12 PM

Sun Paths

9 AM

3 PM 12:00 PM

9:00 AM

Summer Solstice

3:00 PM

E

June 21

E

S

June 21

4:45 AM

N

S

June 21

4:45 AM

N

W

E

4:45 AM

N

W

8:12 PM

S

W

8:12 PM

8:12 PM

12:00 PM 9:00 AM

December 21

December 21

December 21

8:01 AM

8:01 AM

E

S

8:01 AM

E

E

S

S

Winter Solstice

3:00 PM

4:48 PM

N

W

4:48 PM

N

W

Takeaways:The sun diagrams show the building roof is not overshadowed by any surrounding building and the shadows cast onto other buildings are minimal.

4:48 PM

N

W

12:00 PM 9:00 AM

3:00 PM

E

S

March 20

E

Spring/Fall Equinox

6:32 AM

E

6:32 AM

6:37 PM

W

N

S

March 20

6:32 AM

6:37 PM

N

S

March 20

6:37 PM

W

N

W

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

04-01


M

WIN

TER

SU

M

SUN

M

ER

SU

N

WIN

TER

SUN

SU

M

M

ER

SU

N

WIN

TER

SUN

M

ER

SU

N

Side Lighting Entrance

SU

Takeaways: The glass canopy provides minimal shade compared to an opaque canopy. Large windows have been placed to allow light into bedroom suites and the main public entrance. There needs to be a way to light the hallway and circulation spaces.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

04-02


M

WIN

TER

SU

M

SUN

M

ER

SU

N

WIN

TER

SU

M

SUN

M

ER

SU

N

WIN

TER

M

ER

SU

N

Side Lighting Restaurant

SU

SUN Takeaways: The open concept restaurant dining room allows light to travel deep into the building. Large windows have been placed to allow light into bedroom suites as well as the public restaurant space. Further Action is needed to allow more light into hallway cooridoors.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

04-03


Cooling Tower

Mechanical

Mechanical

Mechanical

Furnace

Active Heating and Cooling: The building is equipped with a Variable Air Volume System. The furnace is widely used in larger buildings and is suitable for mixed occupancies. Supply and return ductwork make their way vertically and horizontally throughout the building. The supply duct supplies fresh air to each room and the return duct exhausts the stale air. The boiler moves heated water to the fan room and exhausts through the chimney. The chilled water plant moves cold water to the fan room for air supply ducts. The plant exhausts out the cooling tower. Mini-split systems are used in each hotel unit for individual thermal comfort. Mini-splits in hotel units provide heating and cooling for individual thermal comfort. The south side of the building has extended eaves allowing for more solar shading than the north side. Passive Heating: Solar rays cast sun onto the south side of the building and allows warmth in through the large windows. The sun also reduces building heat load through solar panel technology. Passive Cooling: Large operable windows allow for breeze to enter rooms and refresh air naturally. Active Ventilation: The Variable Air Volume System provides ductwork to supply fresh air and collect stale air from each room. Passive Ventilation: Natural ventilation takes place through the large operable windows.

Active and Passive Heating, Cooling, & Ventilation

Ductwork/Vents Return Air Supply Air Bathroom Vents Mini-split Indoor Unit Mini-split Roof Unit Passive Air Movement Large Operable Windows Solar Rays

Takeaways Each hotel unit has a mini-split in their room for desired thermal comfort levels. Supplying ductwork to each unit would be too expensive.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

05-01


Assembly

1. Typical Roof Assembly: Precast Concrete Parapet EPDM Rubber Membrane Plywood Sheathing Precast Pretensed Hollow-core Concrete Slab 5” Cavity Insulation 3 Layers 5/8” Gypsum Board Ceiling Ceiling Painted Finish

Wall Assembly and Envelope Strategies

1

B

2. Typical Floor Assembly: Bamboo Hardwood Finished Floor Plywood Sheathing Precast Pretensed Hollow-core Concrete Slab 5” Cavity Insulation 3 Layers 5/8” Gypsum Board Ceiling Ceiling Painted Finish

2 C

3. Typical Wall Assembly: Brick Veneer Paneling Air Gap Brick Paneling Clip 2” Rigid Insulation Sheathing 3.5” Cavity Insulation (or Insulated Beam W12 x 26) 3 Layers 5/8” Gypsum Board Interior Painted Finish 4. Columns W10 x 49 Columns 5. Footings 72” x 120” x 18” Rectangular Footings

3

A

Envelope Strategies

A. Glass Panel Canopy with Aluminum Frame: Courtyard shading around building envelope Frame tied back to floor slab B. Large Triple-pane Windows: Insulation and sun access to hotel units U value-0.09 C. Brick Veneer Paneling: Designed to match surrounding campus buildings D. Recessed Curtain Wall Entry: Allows light into lobby

Takeaways: The building would benefit from continuous insulation. There needs to be a roof drain connecting to gutters for water management.

D

4 5

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

06-01


Sink

cu it V

Roof Vent

Plumbing

Cir

en t

Bathtub Toilet Washer Hot-Water Heater

Sink Waste Stack

Takeaways: It is difficult to design water supply systems if fixtures do not share walls. The ventilation for each fixture of the main floor teaching kitchen exhausts through wall vents instead of the roof vent.

Sink Bathtub Toilet Washer Hot-Water Heater

W

Sink

Branch Cleanout Sink

ine ly L p up rS e t a

Sink

Sink

Sink Washer

Hot-Water Heater

Water Meter

W

Ventilation System Drain System Cold Water Supply Hot Water Supply Shut Off Valves

ice erv S r ate

in Ma

ut no a e Cl

er ew S ing ild u B

Drain Sink

e Pip

Main Shut Off Valve

Double Sink Overflow Trap

G

e ag b r a

D

al os p s i

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

07-01


/HYHO 7KUHH

/HYHO 7ZR

Commercial Kitchen

*URXQG /HYHO

:HW 3LSH 6SULQNOHU :HW &KHPLFDO )LUH 6XSSUHVVLRQ

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¶V LQVWDOODWLRQ LQVWUXFWLRQV &DELQHWV &DELQHWV XVHG WR KRXVH SRUWDEOH ILUH H[WLQJXLVKHUV VKDOO QRW EH ORFNHG )LUH $ODUP 6\VWHP LQVWDOOHG &DUERQ PRQR[LGH GHWHFWLRQ LQ SODFH

)LUH 6XSSUHVVLRQ

)LUH 6XSSUHVVLRQ

,%&

7DNHDZD\V 6RPH DUHDV RI WKH ILUVW IORRU GR QRW UHTXLUH D VSULQNOHU V\VWHP EXW WKHUH LV VWLOO RQH LQ SODFH

(PLO\ /LQHKDQ $5&+ %XLOGLQJ 0HGLD 9,, )DOO 6'68 )DFXOW\ +RXVH %URRNLQJV 6RXWK 'DNRWD


Secondary Structure: Exterior Walls: Precast Brick Veneer Paneling Interior Walls: 2x4 Metal Stud Frame with Spray Foam Insulation Attachment Canopy: Glass Panels set in an Aluminum Frame attached (with Aluminum Rods) through the Brick Paneling tied to the Hollow-Core Floor Slab with an Anchor

Primary Structure: 3 Precast Prestressed Hollow-Core Concrete Floors

Primary Structure: 4: Cores with 12" Concrete Walls 3:14' x 24' Rectangular Concrete Footings for Stair Cores 1: 20' x 28' Rectangular Concrete Footing for Elevator Core 68: 6' x 4' x 18" Rectangular Concrete Footings for Columns 68: W10x49 Steel Columns 359: W12x26 Steel Beams

Building Structure

Exploded Structure Diagram

Takeaways: Hollow-core floor slabs minimize floor thickness and reduces total building height. Concrete cores minimize lateral movement. Steel framing minimizes on-site erection time and overall construction time.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

08-01


Surface Parking Spaces (8) 2: ADA (5' clearance for Vehicle Exiting/Entering) ADA Curbs Detectable Warnings before Street Crossing Running Slopes: 8% Cross Slopes: 1% Sidewalks Vehicular Access

ADA Site & Parking

Paved Courtyard Space Sidewalks within

Takeaway: The undersigned underground parking would likely have to have a driveway west of the restaurant. The drop off lane had to become wider, shrinking the small green patch it surrounds.

ADA Site Design and Parking Plan

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

09-01


Men's Restroom 2: Stalls with Wall-mounted Toilet Fixtures 1: Equipped with Turn Radius and Handrails 1: Equipped with Hand Rails 3: Urinal Fixtures 5: Wall-Mounted Sink Fixtures (18" depth) 1: within Turn Radius Stall 2: Covered Garbage Cans 1: Changing Table Women's Restroom 5: Stalls with Wall-mounted Toilet Fixtures 1: Equipped with Turn Radius and Handrails 1: Equipped with Hand Rails 5: Wall-Mounted Sink Fixtures (18" depth) 1: within Turn Radius Stall 2: Covered Garbage Cans 1: Changing Table ADA 5' Radius Minimum Clearance ADA 48" x 30" Minimum Clearance for Sinks and Drinking Fountains Drinking Fountains (8) 6: within Lobby space 1: within Faculty Lounge 1: within Classroom Corridor

ADA Restroom Plan

ADA Restroom Plan

Takeaway: Bathrooms will have wallmounted fixtures to accomodate for ADA knee and toe clearances.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

09-02


Elevator Core 2 Electric Elevators: 4' 4" Door Openings Stair Cores (3)

Southeast Stair Core

Mechanical Room Elevator Access Room Storage Room Janitor's Closet

ADA Building Core

ADA Building Core

.

4' - 4 3/4"

West Stair Core

East Building Core

4' - 4 3/4"

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

09-03


Project Checklist Y

?

SDSU FACULTY HOUSE 11/12/2018

N Credit

10 0

Project Name: Date:

Integrative Process

0 Location and Transportation

1 16

Credit

LEED for Neighborhood Development Location

Credit

Sensitive Land Protection

1

2

Credit

High Priority Site

5

Credit

2

0

0 Materials and Resources

13

Prereq

Storage and Collection of Recyclables

Required

Prereq

Construction and Demolition Waste Management Planning

Required

2

Credit

5

Surrounding Density and Diverse Uses

5

Credit

Credit

Access to Quality Transit

5

Credit

Building Life-Cycle Impact Reduction Building Product Disclosure and Optimization - Environmental Product Declarations Building Product Disclosure and Optimization - Sourcing of Raw Materials

1

Credit

Bicycle Facilities

1

Credit

2

1

Credit

Reduced Parking Footprint

1

Building Product Disclosure and Optimization - Material Ingredients Construction and Demolition Waste Management

1

Credit

Green Vehicles

1

4

0

Y

0 Sustainable Sites

16

10

Prereq

Construction Activity Pollution Prevention

Credit

Site Assessment

1

Required

Y

Y

2

Credit

13 0 Y

Y

0 Indoor Environmental Quality

2 2 2

16

Prereq

Minimum Indoor Air Quality Performance

Required

Prereq

Environmental Tobacco Smoke Control

Required

Credit

Enhanced Indoor Air Quality Strategies

2

Credit

Low-Emitting Materials

3

Credit

1

Credit

Site Development - Protect or Restore Habitat

2

1

Credit

Open Space

1

3

Credit

Rainwater Management

3

2

Credit

Construction Indoor Air Quality Management Plan Indoor Air Quality Assessment

Credit

Heat Island Reduction

2

1

Credit

Thermal Comfort

1

Credit

Light Pollution Reduction

1

2

Credit

Interior Lighting

2

3

Credit

Daylight

3

1

Credit

Quality Views

1

1

Credit

Acoustic Performance

1

11 0

0 Water Efficiency

11

Prereq

Outdoor Water Use Reduction

Required

Y

Prereq

Indoor Water Use Reduction

Required

Y

Prereq

2

Building-Level Water Metering Outdoor Water Use Reduction

Required

Credit

6

Credit

Indoor Water Use Reduction

6

2

Credit

Cooling Tower Water Use

2

1

Credit

Water Metering

1

Y

3

0

0 Energy and Atmosphere

2

3

0

0

0

0

33

2

0 Innovation Credit

Innovation

Credit

LEED Accredited Professional

6 5 1

0 Regional Priority

4

Credit

Regional Priority: Specific Credit

Credit

Regional Priority: Specific Credit

1 1

Prereq

Fundamental Commissioning and Verification

Required

Credit

Regional Priority: Specific Credit

1

Y

Prereq

Minimum Energy Performance

Required

Credit

Regional Priority: Specific Credit

1

Y

Prereq

Building-Level Energy Metering

Required

Y

Prereq

Fundamental Refrigerant Management

Required

Credit

Enhanced Commissioning

6

Credit

Optimize Energy Performance

18

Credit

Advanced Energy Metering

1

Credit

Demand Response

2

Credit

Renewable Energy Production

3

Credit

Enhanced Refrigerant Management

1

Credit

Green Power and Carbon Offsets

2

Y

3

43 0

0 TOTALS

LEED Checklist

LEED v4 for BD+C: New Construction and Major Renovation

Possible Points:

Certified: 40 to 49 points, Silver: 50 to 59 points, Gold: 60 to 79 points, Platinum: 80 to 110

Takeaways: Certain points can be earned through small changes in design. Knowing to incorporate these easy changes can lead to an overall better building.

110

Type: LEED BD+C Hospitality Points Earned: 43 Project Gross Square Footage: 61,818 SF Property Area: 165' x 230' The LEED points earned reflect a healthier environment and lifestyle for the users and surrounding sites.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

10-01


Water Efficiency Cooling Tower Water Use 2 Points Variable Air Volume System uses a cooling tower to vent the chilled water plant and is meant to conserve water used for cooling tower makeup while controlling microbes, corrosion, and scale in the condenser water system.

LEED Specifics

Sustainable Sites Open Space 1 Point Courtyard space is larger than 30% of the building footprint with 25% of that space being a green space. The space provides for environmental and social interactions and passive activities.

Energy and Atmosphere Renewable Energy Production 3 Points South facing solar energy panels on the building's roof are used to offset the building's energy demand.

Indoor Environmental Quality Low-Emitting Materials 3 Points Materials are chosen to reduce concentrations of chemical contaminants that can damage air quality, human health, productivity, and the environment. Materials and Resources Construction Demolition and Waste Management 2 Points By using a precast paneling system, the construction process because cleaner with less waste than traditional brick and mortar. The time demand is also less. The construction process will not generate more than 2.5 pounds of waste per square foot of the building's total floor area.

Location and Transportation Bicycle Facilities 1 Point Bicycle storage for short and long term visits promotes healthy transportation and an environmentally responsible alternative to vehicular transportation.

Takeaways: There may be ability to increase the amount of solar panels on the roof to offset the energy costs of the building. The green space in the north courtyard needed to increase slightly to meet the Open Space Credit.

Emily Linehan ARCH522 Building Media VII Fall 2018 SDSU Faculty House Brookings, South Dakota

10-02


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.