12/1/2015 5:23:55 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
Murphy USA 200 Peach Street El Dorado, AR 71730
Project Team Architect Westlake Reed Leskosky 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
HEADQUARTERS RENOVATION
Structural Engineers Westlake Reed Leskosky 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
BID/PERMIT SET 12/01/2015 Architectural Symbol Legend
Project Description COMPLETE INTERIOR RENOVATION OF EXISTING 140,000 SF, 4-STORY HEADQUARTERS FOR MURPHY USA. RENOVATION INCLUDES REDISTRIBUTION OF OFFICE DEPARTMENTS, OPEN OFFICE SPACE, VENDOR DEMONSTRATION AREA, PROTOTYPE STORE (N.I.C.), AND UPDATED AMENITIES SUCH AS A CAFETERIA, VENDING, TRAINING ROOMS, EXTERIOR PATIO IMPROVEMENTS AND CONFERENCE/TEAMING SPACES.
Room name
1
ROOM TAG WITH AREA
101
R101
150 SF
View Name 1/8" = 1'-0"
REFERENCE SHEET
NEW COLUMN CENTER LINE THE BUILDING IS OCCUPANCY GROUP B BUSINESS. THERE IS NO PROPOSED CHANGE IN BUILDING USE GROUP. THERE ARE ACCESSORY PA AND M GROUPS ON THE FIRST FLOOR, BUT NO MIXED OCCUPANCIES. THE FLOOR AREA AND SO OCCUPANCY COUNT IS BEING SLIGHTLY INCREASED DUE TO A PATIO ENCLOSURE AND A CONFERENCE ROOM STRUCTURE ON FLOORS 2-4 . THE BUILDING IS FULLY SPRINKLERED EXCEPT AT ATRIUM CEILING. THE ATRIUM SMOKE EXHAUST SYSTEM IS BEING UPGRADED TO MEET CURRENT CODE. A FORMAL ANAYLSIS HAS BEEN GENERATED BASED ON A COMPUTATIONAL MODEL WHICH SERVED AS A BASIS OF DESIGN WHICH IS AVAILABLE FOR REVIEW IN THE SPECIFICATION APPENDIX.
EXISTING COLUMN CENTER LINE
NEW WALL
CONTRACT LIMIT LINE
EXISTING WALL
SIM
1 A101
DEMOLITION
CALLOUT TAG 1
1 A101
1 A101
1 HOUR RATED WALL
SIM
DETAIL CUT
A101
Vicinity Map
DETAIL VIEW TAG
2 HOUR RATED WALL
SIM
BUILDING SECTION CUT SIM
3
WALL SECTION CUT WALL TYPE
A301
DOOR TYPE
1t
WINDOW TYPE
Name Elevation
ELEVATION LEVEL
1
INTERIOR ELEVATION TAG
1
EXTERIOR ELEVATION TAG
4
A101
101
1i
3 HOUR RATED WALL
2
XX.XXX ?
PROJECT SITE
KEYNOTE TAG CSI DIVISION
CODE REFERENCES
Drawn by:
MM
Checked by:
Checker
Architectural Abbreviation Legend AFF. ACOUST. ACOUST. ACP ACT AWC AWF AWP ADJ. SH. A/C AHU ALT. AL. ALUM. AB. L APPROX. ARCH. A.D. ASPH. ASSY. @ AUTO AWN. AESS
ABOVE FINISHED FLOOR ACOUSTIC ACOUSTICAL ACOUSTICAL CEILING PANEL ACOUSTICAL CEILING TILE ACOUSTICAL WALL CARPET ACOUSTICAL WALL FABRIC ACOUSTICAL WALL PANEL ADJUSTABLE SHELF AIR CONDITIONING AIR HANDLING UNIT ALTERNATE ALUMINUM ALUMINUM ANCHOR BOLT ANGLE APPROXIMATE ARCHITECT ASH DUMP ASPHALT ASSEMBLY AT, ABOUT, AROUND AUTOMATIC AWNING ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
BALC. B BSMT BATH. BM B.R. BMRK BLK BLKG BD BK.SH. BOTT. BRKT. BR B.C. BLDG. BLT-IN BUR
BALCONY BASE BASEMENT BATHROOM BEAM BEDROOM BENCH MARK BLOCK BLOCKING BOARD BOOK SHELVES BOTTOM BRACKET BRICK BROOM CLOSET BUILDING BUILT IN BUILT-UP ROOF
CAB. C CPT CSMT C.I. CB CLG CEM CL CER C.T. CO CLR CLO COL CBP CONC CMU CONST. CONT. CONTR C.J. COP C.G. CORR. CTR CSMS CSWS CRS. CC
CABINET CARPET CARPET CASEMENT CAST IRON CATCH BASIN CEILING CEMENT CENTER LINE CERAMIC CERAMIC TILE CLEAN OUT OR CASED OPENING CLEAR CLOSET COLUMN COMPOSITE BUILDING PANELS CONCRETE CONCRETE MASONRY UNIT CONSTRUCTION CONTINUOUS CONTRACTOR CONTROL JOINT COPPER CORNER GUARD CORRIDOR COUNTER COUNTERSUNK METAL SCREW COUNTERSUNK WOOD SCREW COURSES CUBICLE CURTAIN
DL DET DIA DIFF DIM DO DR DP DH DN DS D DWR DWG DWGS DF DUP.
DEAD LOAD DETAIL DIAMETER DIFFUSER DIMENSION DITTO DOOR DOOR PROTECTOR DOUBLE HUNG DOWN DOWN SPOUT DRAIN DRAWER DRAWING DRAWINGS DRINKING FOUNTAIN DUPLICATOR
EA E E.W.C. ELEC. ELECT. ELEV. ELEV. EMERG EG ENGR EQ. EQUIP EXIST. E.T.R. EXP EB EXP JT EXPC EXT. E.I.F.S.
EACH EAST ELECTRIC WATER COOLER ELECTRICAL ELECTRICAL ELEVATION ELEVATOR EMERGENCY END GUARD ENGINEER EQUAL EQUIPMENT EXISTING EXISTING TO REMAIN EXPANSION EXPANSION BOLT EXPANSION JOINT EXPOSED CONSTRUCTION EXTERIOR EXTERIOR INSULATION AND FINISH SYSTEM
FWC FWS FT F.N.D. F.N.DISP. FG F.V. FIN F.G. FDV F.E. FEC FHC FP FP FIX FLASH. FLEX. FL F.D. FD FLUOR FT. FTG. FDN. FR'MG FURN
FABRIC WALL COVERING FABRIC WALL SYSTEM FEET FEMININE NAPKIN DISPENSER FEMININE NAPKIN DISPOSAL FIBER GLASS FIELD VERIFY FINISH FINISH GRADE FIRE DEPARTMENT VALVE FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FIREPROOF FIREPROOFING FIXTURE FLASHING FLEXIBLE FLOOR FLOOR DRAIN FLOOR DRAIN FLUORESCENT FOOT FOOTING FOUNDATION FRAMING FURNACE
GA GALV GEN. GL GLB G.B. GR GT GFI
GAGE GALVANIZED GENERATOR GLASS GLASS BLOCK GRAB BAR GRADE GRANITE TILE GROUND FAULT CIRCUIT INTERRUPTER GUTTER GYPSUM BOARD
GUTT GYP. BD. HR HDW HD WD HD HVAC
H.P. HC HM HORIZ HB HOSP HC HB HR
HAND RAIL HARDWARE HARDWOOD HEAD HEATING, VENTILATING, AND AIR CONDITIONING HEIGHT HEIGHT HIGH PERFORMANCE ARCHITECTURAL COATING HIGH POINT HOLLOW CORE HOLLOW METAL HORIZONTAL HOSE BIBB HOSPITAL HOT AND COLD HOSE BIBB HOUR
IN INFO I.D. INS INSUL. IR INT
INCH INFORMATION INSIDE DIAMETER INSULATED INSULATION INTEGRAL RESILIENT BASE INTERIOR
JAN. JT. JST
JANITOR JOINT JOIST
LAB LAM LC LAV LT.
LABORATORY LAMINATE LAUNDRY CHUTE LAVATORY LIGHT
HGT. HT HPAC
LIN. DIFF. LIN LL LLV L.P.
LINEAR DIFFUSER LINEN CLOSET LIVE LOAD LONG LEG VERTICAL LOW POINT
MACH. MH MFD MFR MT MK MB MAS'Y M.O. MAT'L MAX. MECH. M.C. MEMB. MTL MFTSM MIN. MIN MISC MOD MLDG
MACHINE MANHOLE MANUFACTURED MANUFACTURER MARBLE TILE MARK MARKER BOARD MASONRY MASONRY OPENING MATERIAL MAXIMUM MECHANICAL MEDICINE CHEST MEMBRANE METAL MINERAL-FILLED THERMOPLASTIC SURFACING MATERIAL MINIMUM MINUTE MISCELLANEOUS MODIFIED MOLDING
NF NOM. N N/A N.I.C. N.T.S NO
NATURAL FINISH NOMINAL NORTH NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE NUMBER
OFF O.C. OPN'G OPP O.H. ORCH. OP OPL O.D. O.H. O.H. OFE
OFFICE ON CENTER OPENING OPPOSITE OPPOSITE HAND ORCHESTRA ORNAMENTAL PAINT ORNAMENTAL PLASTER OUTSIDE DIAMETER OVERHANG OVERHEAD OWNER FURNISHED EQUIPMENT, CONTRACTOR INSTALLED OXYGEN
OXY P P2M
PAINT PAINT TO MATCH, PATCH TO MATCH PT'D. PAINTED PR PAIR PNL PANEL P.T.D. PAPER TOWEL DISPENSER PART'N PARTITION PTC PEDESTRIAN TRAFFIC COATING PERF PERFORATED PCS PIECES PL PLASTIC LAMINATE P.LAM. PLASTIC LAMINATE PLAS PLASTIC OR PLASTER PL PLATE P.S.F. POUNDS PER SQUARE FOOT P.S.I. POUNDS PER SQUARE INCH P.C. PRECAST CONCRETE PC CONC PRECAST CONCRETE PREFAB PREFABRICATED PRE PREFINISHED PP PRIME PAINT PROD. PRODUCTION PRJ. PROJECTOR SCREEN SCR. QTY Q.T.
QUANTITY QUARRY TILE
R RDWD REF REF REINF REBAR REX REQ'D R RSF RA REV R R&S R.D.
RADIUS REDWOOD REFERENCE REFRIGERATOR REINFORCING REINFORCING BAR REMOVE EXISTING REQUIRED RESILIENT BASE RESILIENT SHEET FLOORING RETURN AIR REVISION RISERS ROD AND SHELF ROOF DRAIN
RM RO R.S. R.S.C.
ROOM ROUGH OPENING ROUGH SAWN ROUGH SAWN CEDAR
SCH SECT SHTHG SHT SH SLV SIM SPR SL GL DR SP S.A.P. S SC SPECS SQ SF SQ FT S&V S.S. STD STL C SJ S STN STOR STRUCT. S4S S1S S3S S2S SUSP SW SYM
SCHEDULE SECTION SHEATHING SHEET SHELF SHORT LEG VERTICAL SIMILAR SINGLE PLY ROOFING SLIDING GLASS DOOR SOLID POLYMER SOUND ABSORTIVE PANELS SOUTH SPECIAL COATING SPECIFICATIONS SQUARE SQUARE FEET SQUARE FEET STAIN AND VARNISH STAINLESS STEEL STANDARD STEEL STEEL CHANNEL STEEL JOIST STONE STONE STORAGE STRUCTURAL SURFACE FOUR SIDES SURFACE ONE SIDE SURFACE THREE SIDES SURFACE TWO SIDES SUSPENDED SWITCH SYMMETRICAL
TB TELE. TV TEMP TEMP TCSS TCS TERR THICK TH'K. T.T.D. T&G T.O.S. T.O.STL. TRD TYP
TACKBOARD TELEPHONE TELEVISION TEMPERED TEMPORARY TERNE COATED STAINLESS STEEL TERNE COATED STEEL TERRAZZO THICK TOILET TISSUE DISPENSER TONGUE AND GROOVE TOP OF SLAB TOP OF STEEL TREAD TYPICAL
U.C. U.C. U.C.R.
UNDER CABINET UNDER COUNTER UNDER COUNTER REFRIGERATOR UNFINISHED UNLESS NOTED OTHERWISE
UNFIN U.N.O. V VAC V.B. VEN VP V.P. V.I.F. VERT. VEST. VCT VWC MAT W.B.R. W CAB WC WP WC WP WRB WP WT WWF W WF WTH WIND. W.O. W/ W/O WD. WP WP
VACUUM VAPOR BARRIER VENEER VENEER PANELING VENEER PLASTER VERIFY IN FIELD VERTICAL VESTIBULE VINYL COMPOSITION TILE VINYL WALL COVERING WALK-OFF MAT WALL BUMPER RAIL WALL CABINET WALL CARPET WALL PROTECTOR WATER CLOSET WATER PROOF WATER RESISTANT CEMENT BOARD WEATHER PROOF WEIGHT WELDED WIRE FABRIC WEST WIDE FLANGE WIDTH WINDOW WINDOW OPENING WITH WITHOUT WOOD WOOD PANELING WORK POINT
APPLICABLE BUILDING CODE:
2012 ARKANSAS FIRE PREVENTION CODE VOL II
ZONING CODE:
CITY OF EL DORADO ZONING CODE
ACCESSIBILITY CODE:
2012 ARKANSAS FIRE PREVENTION CODE VOL II
FIRE CODE:
2012 ARKANSAS FIRE PREVENTION CODE VOL I
MECHANICAL CODE:
ARKANSAS STATE MECHANICAL CODE
PLUMBING CODE:
2006 ICC ARKANSAS SPECIFIC PLUMBING CODE
ELECTRICAL CODE:
ARKANSAS (NATIONAL) ELECTRICAL CODE
ENERGY CODE:
ARKANSAS ENERGY CODE / ASHRAE 90.1 2007 WITH AMMENDMENTS
HEALTH CODE:
2012 ARKANSAS STATE BOARD OF HEALTH RULES AND REGULATIONS PERTAINING TO FOOD ESTABLISHMENTS
SIGNAGE CODE:
CITY OF EL DORADO SIGNAGE ORDINANCE
PRESERVATION CODE:
CITY OF EL DORADO HISTORIC DISTRICT DESIGN GUIDELINES
OTHER:
2006 INTERNATIONAL FUEL GAS CODE
CHAPTER 29
PLUMBING SYSTEMS
TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES OCCUPANCY Business, B WATER CLOSETS 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 LAVATORIES 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 DRINKING FOUNTAINS 1 per 100 OTHER 1 Service Sink MURPHY USA - PLUMBING FIXTURE COUNT REQUIRED FLR. PERSONS WC LAVS B 45 1.80 1.13 1 611 13.22 8.64 2 430 9.60 6.38 3 398 8.96 5.98 417 9.34 6.21 4 T 1901 42.92 28.33
DF 0.45 6.11 4.30 3.98 4.17 19.01
PROVIDED WC LAVS 1 1 13 9 12 8 12 8 15 10 53 36
DF* 1 6 4 4 4 19
*WATER COOLERS WILL BE ADDED TO MEET REQUIREMENTS. NOTE: Occupant load used to calculate plumbing fixtures.
MEP Engineers Westlake Reed Leskosky 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
Civil Engineers
McClelland Consulting Engineers, Inc. 900 West Markham Street Little Rock, Arkansas 72201 501.371.0272
Fire Protection Engineers
Drawing Index GENERAL G-001 COVER SHEET G-100 LIFE SAFETY PLANS G-101 LIFE SAFETY PLANS CIVIL C-101 C-111 C-121 C-131
EXISTING CONDITIONS PLAN EROSION CONTROL & DEMOLITION PLAN UTILITY PLAN & DRAINAGE PLAN CIVIL MISCELLANEOUS DETAILS
STRUCTURAL S-001 GENERAL STRUCTURAL NOTES S-002 GENERAL STRUCTURAL NOTES S-100 BASEMENT PLAN S-101 FIRST FLOOR FRAMING / FOUNDATION PLAN S-101A CANOPY FOUNDATION PLANS S-102 SECOND FLOOR FRAMING PLAN S-102A CANOPY ROOF FRAMING PLANS S-103 THIRD FLOOR FRAMING PLAN S-104 FOURTH FLOOR FRAMING PLAN S-105 ROOF FRAMING PLAN S-501 TYPICAL CONCRETE SECTIONS & DETAILS S-502 CONCRETE SECTIONS & DETAILS S-503 CONCRETE SECTIONS & DETAILS S-504 TYPICAL CONCRETE SECTIONS & DETAILS S-510 COLUMN SCHEDULES, ANCHOR BOLTS & BASE PLATES S-511 TYPICAL STEEL SECTIONS & DETAILS S-512 TYPICAL STEEL SECTIONS & DETAILS S-513 STEEL SECTIONS & DETAILS S-514 STEEL SECTIONS & DETAILS S-515 CANOPY MEMBER GEOMETRY S-516 CANOPY MEMBER GEOMETRY S-517 CANOPY SECTIONS & DETAILS S-518 CANOPY SECTIONS & DETAILS S-520 TYPICAL MASONRY SECTIONS & DETAILS ARCHITECTURAL AD-100 BASEMENT DEMO PLAN AD-101 FIRST FLOOR DEMO PLAN AD-102 SECOND FLOOR DEMO PLAN AD-103 THIRD FLOOR DEMO PLAN AD-104 FOURTH FLOOR DEMO PLAN AD-105 PENTHOUSE DEMO PLAN AD-120 BASEMENT DEMO REFLECTED CEILING PLAN AD-121 FIRST FLOOR DEMO REFLECTED CEILING PLAN AD-122 SECOND FLOOR DEMO REFLECTED CEILING PLAN AD-123 THIRD FLOOR DEMO REFLECTED CEILING PLAN AD-124 FOURTH FLOOR DEMO REFLECTED CEILING PLAN AD-125 PENTHOUSE FLOOR REFLECTED CEILING PLAN A-100 BASEMENT PLAN A-101 FIRST FLOOR PLAN A-102 SECOND FLOOR PLAN A-103 THIRD FLOOR PLAN A-104 FOURTH FLOOR PLAN A-105 PENTHOUSE FLOOR PLAN A-106 ENCLOSED PATIO ALTERNATE A-120 BASEMENT REFLECTED CEILING PLAN A-121 FIRST FLOOR REFLECTED CEILING PLAN A-122 SECOND FLOOR REFLECTED CEILING PLAN A-123 THIRD FLOOR REFLECTED CEILING PLAN A-124 FOURTH FLOOR REFLECTED CEILING PLAN A-125 PENTHOUSE FLOOR REFLECTED CEILING PLAN A-201 EXTERIOR ELEVATIONS A-301 BUILDING SECTIONS A-310 WALL SECTIONS A-401 ENLARGED RESTROOM PLANS & ELEVATIONS A-402 ENLARGED PLANS & ELEVATIONS A-403 ENLARGED PLANS & ELEVATIONS A-411 INTERIOR ELEVATIONS A-412 INTERIOR ELEVATIONS A-421 ENLARGED STAIR PLANS & SECTIONS A-422 ENLARGED STAIR PLANS & SECTIONS A-423 STAIR DETAILS A-431 ENLARGED PLANS & ELEVATIONS - OVAL CONF. A-432 SECTIONS & DETAILS - OVAL CONF. A-441 ENLARGED ELEVATOR PLANS & ELEVATIONS A-501 EXTERIOR DETAILS A-502 EXTERIOR DETAILS A-503 EXTERIOR DETAILS A-511 INTERIOR DETAILS A-512 INTERIOR DETAILS A-513 INTERIOR DETAILS A-531 MILLWORK DETAILS A-532 MILLWORK DETAILS A-533 MILLWORK DETAILS A-561 CEILING DETAILS A-562 CEILING DETAILS A-600 PARTITION TYPES A-610 DOOR AND FRAME SCHEDULE A-615 DOOR HEAD AND JAMB DETAILS INTERIORS I-001 FINISH SCHEDULE I-002 FURNITURE SCHEDULE I-100 BASEMENT FINISH PLAN I-101 FIRST FLOOR FINISH PLAN I-102 SECOND FLOOR FINISH PLAN I-103 THIRD FLOOR FINISH PLAN I-104 FOURTH FLOOR FINISH PLAN I-105 PENTHOUSE FLOOR FINISH PLAN I-200 BASEMENT FURNITURE PLAN I-201 FIRST FLOOR FURNITURE PLAN I-202 SECOND FLOOR FURNITURE PLAN I-203 THIRD FLOOR FURNITURE PLAN I-204 FOURTH FLOOR FURNITURE PLAN
FIRE PROTECTION F-001 FIRE PROTECTION SYMBOL LEGEND, GENERAL NOTES, AND ABBREVIATIONS FD-100 BASEMENT FIRE PROTECTION DEMOLITION PLAN FD-101 FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN FD-102 SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN FD-103 THIRD FLOOR FIRE PROTECTION DEMOLITION PLAN FD-104 FOURTH FLOOR FIRE PROTECTION DEMOLITION PLAN FD-105 PENTHOUSE AND ATRIUM FIRE PROTECTION DEMOLITION PLAN F-100 BASEMENT AND CANOPY FIRE PROTECTION PLAN F-101 FIRST FLOOR FIRE PROTECTION PLAN F-102 SECOND FLOOR FIRE PROTECTION PLAN F-103 THIRD FLOOR FIRE PROTECTION PLAN F-104 FOURTH FLOOR FIRE PROTECTION PLAN F-105 PENTHOUSE AND ATRIUM FIRE PROTECTION PLAN F-501 FIRE PROTECTION DETAILS PLUMBING P-001 PLUMBING GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND SCHEDULES PD-100.1 BASEMENT SANITARY, STORM, & VENT PIPING DEMOLITION PLAN PD-100.2 BASEMENT DOMESTIC WATER PIPING DEMOLITION PLAN PD-101.1 FIRST FLOOR SANITARY, STORM, & VENT PIPING DEMOLITION PLAN PD-101.2 FIRST FLOOR DOMESTIC WATER PIPING DEMOLITION PLAN PD-102.1 SECOND FLOOR SANITARY, STORM, & VENT PIPING DEMOLITION PLAN PD-102.2 SECOND FLOOR DOMESTIC WATER PIPING DEMOLITION PLAN PD-103.1 THIRD FLOOR SANITARY, STORM, & VENT PIPING DEMOLITION PLAN PD-103.2 THIRD FLOOR DOMESTIC WATER PIPING DEMOLITION PLAN PD-104.1 FOURTH FLOOR SANITARY, STORM, & VENT PIPING DEMOLITION PLAN PD-104.2 FOURTH FLOOR DOMESTIC WATER PIPING DEMOLITION PLAN P-100.1 BASEMENT SANITARY, STORM, & VENT PIPING PLAN P-100.2 BASEMENT DOMESTIC WATER PIPING PLAN P-101.1 FIRST FLOOR SANITARY, STORM, & VENT PIPING PLAN P-101.2 FIRST FLOOR DOMESTIC WATER PIPING PLAN P-102.1 SECOND FLOOR SANITARY, STORM, & VENT PIPING PLAN P-102.2 SECOND FLOOR DOMESTIC WATER PIPING PLAN P-103.1 THIRD FLOOR SANITARY, STORM, & VENT PIPING PLAN P-103.2 THIRD FLOOR DOMESTIC WATER PIPING PLAN P-104.1 FOURTH FLOOR SANITARY, STORM, & VENT PIPING PLAN P-104.2 FOURTH FLOOR DOMESTIC WATER PIPING PLAN P-501 PLUMBING DETAILS P-502 PLUMBING DETAILS P-901 STACK DIAGRAM MECHANICAL M-001 MECHANICAL SYMBOLS & ABBREVIATIONS MD-100 MECHANICAL BASEMENT FLOOR PLAN - DEMOLITION MD-101 MECHANICAL FIRST FLOOR PLAN - DEMOLITION MD-102 MECHANICAL SECOND FLOOR PLAN - DEMOLITION MD-103 MECHANICAL THIRD FLOOR PLAN - DEMOLITION MD-104 MECHANICAL FOURTH FLOOR PLAN - DEMOLITION MD-105 MECHANICAL PENTHOUSE FLOOR PLAN - DEMOLITION M-100 MECHANICAL BASEMENT FLOOR PLAN - NEW WORK M-101 MECHANICAL FIRST FLOOR PLAN - NEW WORK M-102 MECHANICAL SECOND FLOOR PLAN - NEW WORK M-103 MECHANICAL THIRD FLOOR PLAN - NEW WORK M-104 MECHANICAL FOURTH FLOOR PLAN - NEW WORK M-105 MECHANICAL PENTHOUSE PLAN - NEW WORK MP-100 MECHANICAL PIPING BASEMENT FLOOR PLAN MP-101 MECHANICAL PIPING FIRST FLOOR PLAN MP-102 MECHANICAL PIPING SECOND FLOOR PLAN MP-103 MECHANICAL PIPING THIRD FLOOR MP-104 MECHANICAL PIPING FOURTH FLOOR M-401 MECHANICAL ENLARGED PLAN - SIMILAR EAST AND WEST MECHANCIAL ROOMS M-501 MECHANICAL DETAILS M-502 MECHANICAL DETAILS M-503 MECHANICAL DETAILS M-601 MECHANICAL SCHEDULES M-602 MECHANICAL SCHEDULES M-603 MECHANICAL SCHEDULES M-701 MECHANICAL CONTROLS M-702 MECHANICAL CONTROLS ELECTRICAL E-001 ELECTRICAL GENERAL NOTES E-002 ELECTRICAL SYMBOLS AND ABBREVIATIONS ED-100 BASEMENT ELECTRICAL DEMOLITION PLAN ED-101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN ED-102 SECOND FLOOR ELECTRICAL DEMOLITION PLAN ED-103 THIRD FLOOR ELECTRICAL DEMOLITION PLAN ED-104 FOURTH FLOOR ELECTRICAL DEMOLITION PLAN ED-105 PENTHOUSE ELECTRICAL DEMOLITION PLAN ED-601 DEMO SINGLE-LINE DIAGRAM ED-602 DEMO SINGLE-LINE DIAGRAM EL-100 BASEMENT LIGHTING PLAN EL-101 FIRST FLOOR LIGHTING PLAN EL-102 SECOND FLOOR LIGHTING PLAN EL-103 THIRD FLOOR LIGHTING PLAN EL-104 FOURTH FLOOR LIGHTING PLAN EL-105 PENTHOUSE LIGHTING PLAN EL-611 INTERIOR LIGHTING FIXTURE SCHEDULE EL-612 LIGHTING CONTROL SCHEDULE & TYPICAL CONTROL DIAGRAM EL-613 LIGHTING DETAILS EP-100 BASEMENT POWER PLAN EP-101 FIRST FLOOR POWER PLAN EP-102 SECOND FLOOR POWER PLAN EP-103 THIRD FLOOR POWER PLAN EP-104 FOURTH FLOOR POWER PLAN EP-105 PENTHOUSE POWER PLAN EP-200 BASEMENT MECHANICAL POWER PLAN
EP-201 EP-202 EP-203 EP-204 EP-205 EY-100 EY-101 EY-102 EY-103 EY-104 EY-105 E-401 E-402 E-501 E-502 E-601 E-602 E-612 E-631 E-632 E-633 E-634
FIRST FLOOR MECHANICAL POWER PLAN SECOND FLOOR MECHANICAL POWER PLAN THIRD FLOOR MECHANICAL POWER PLAN FOURTH FLOOR MECHANICAL POWER PLAN PENTHOUSE MECHANICAL POWER PLAN BASEMENT SPECIAL SYSTEMS PLAN FIRST FLOOR SPECIAL SYSTEMS PLAN SECOND FLOOR SPECIAL SYSTEMS PLAN THIRD FLOOR SPECIAL SYSTEMS PLAN FOURTH FLOOR SPECIAL SYSTEMS PLAN PENTHOUSE SPECIAL SYSTEMS PLAN ENLARGED ELECTRICAL ROOM PLANS ENLARGED PLANS ELECTRICAL DETAILS ELECTRICAL DETAILS SINGLE-LINE DIAGRAM SINGLE-LINE DIAGRAM MECHANICAL EQUIPMENT SCHEDULE ELECTRICAL PANEL SCHEDULES ELECTRICAL PANEL SCHEDULES ELECTRICAL PANEL SCHEDULES ELECTRICAL PANEL SCHEDULES
Jensen Hughes, Inc. 3610 Commerce Drive, Suite 817 Baltimore, MD 21227 410.737.8677
Landscape Architects P. Allen Smith & Associates P.O. Box 164870 Little Rock, Arkansas 72216 501.376.1894
TELECOMMUNICATION TD-100 BASEMENT TELECOMMUNICATION DEMO PLAN TE-001 TELECOMMUNICATION ABBREVIATIONS, GEN. NOTES, LEGENDS & SYMBOLS TE-100 BASEMENT TELECOMMUNICATION PLANS TE-101 FIRST FLOOR TELECOMMUNICATION PLAN TE-102 SECOND FLOOR TELECOMMUNICATION PLAN TE-103 THIRD FLOOR TELECOMMUNICATION PLAN TE-104 FOURTH FLOOR TELECOMMUNICATION PLAN TE-111 FIRST FLOOR TELECOMMUNICATION RCP TE-112 SECOND FLOOR TELECOMMUNICATION RCP TE-113 THIRD FLOOR TELECOMMUNICATION RCP TE-114 FOURTH FLOOR TELECOMMUNICATION RCP TE-401 WIRING CLOSET 121 PLANS TE-402 WIRING CLOSET 140 PLANS TE-403 WIRING CLOSET 228 PLANS TE-404 WIRING CLOSET 246 PLANS TE-405 WIRING CLOSET 327 PLANS TE-406 WIRING CLOSET 344 PLANS TE-407 WIRING CLOSET 418 PLANS TE-408 WIRING CLOSET 448 PLANS TE-501 TELECOMMUNICATION DETAILS TE-502 TELECOMMUNICATION DETAILS TE-601 TELECOMMUNICATION RISER DIAGRAM AUDIO VISUAL TA-001 AV NOTES TA-101 1ST FLOOR AV WIRING DEVICE PLAN TA-102 2ND FLOOR AV WIRING DEVICE PLAN TA-103 3RD FLOOR AV WIRING DEVICE PLAN TA-104 4TH FLOOR AV WIRING DEVICE PLAN TA-111 1ST FLOOR AV EQUIPMENT PLAN TA-112 2ND FLOOR AV EQUIPMENT PLAN TA-113 3RD FLOOR AV EQUIPMENT PLAN TA-114 4TH FLOOR AV EQUIPMENT PLAN TA-201 1ST FLOOR AV WIRING DEVICE RCP TA-202 2ND FLOOR AV WIRING DEVICE RCP TA-203 3RD FLOOR AV WIRING DEVICE RCP TA-204 4TH FLOOR AV WIRING DEVICE RCP TA-211 1ST FLOOR AV EQUIPMENT RCP TA-212 2ND FLOOR AV EQUIPMENT RCP TA-213 3RD FLOOR AV EQUIPMENT RCP TA-214 4TH FLOOR AV EQUIPMENT RCP TA-301 AV ELEVATIONS TA-501 AV DETAILS TA-511 AV RACK ELEVATIONS TA-601 AV WIRING DEVICE SCHEDULE TA-602 AV WIRING DEVICE SCHEDULE TA-603 AV WIRING DEVICE SCHEDULE TA-604 AV WIRING DEVICE SCHEDULE TA-605 AV WIRING DEVICE SCHEDULE TA-606 AV WIRING DEVICE SCHEDULE TA-611 AV BLOCK DIAGRAM TA-612 AV BLOCK DIAGRAM TA-613 AV BLOCK DIAGRAM TA-614 AV BLOCK DIAGRAM TA-615 AV BLOCK DIAGRAM TA-616 AV BLOCK DIAGRAM TA-621 AV CONDUIT RISER DIAGRAM & SCHEDULE
Murphy USA
Commision # 15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
COVER SHEET
CD
G-001
12/1/2015 4:22:26 PM
1005.3.2 Other egress components. The capacity, in inches (mm), of means of egress components other than stairways shall be calculated by multiplying the occupant load served by such component by a means of egress capacity factor of 0.2 inch (5.1 mm) per occupant.
CODE SUMMARY CHAPTER 3
USE AND OCCUPANCY (Arkansas Fire Prevention Code Volume II Building)
Exception: For other than Group H and I-2 occupancies, the capacity, in inches (mm), of means of egress components other than stairways shall be calculated by multiplying the occupant load served by such component by a means of egress capacity factor of 0.15 inch (3.8 mm) per occupant in buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2 and an emergency voice/alarm communication system in accordance with Section 907.5.2.2.
302 CLASSIFICATION 304 Business Group (B) CHAPTER 4
SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY (Arkansas Fire Prevention Code Volume II Building)
1005.6 Egress convergence. Where the means of egress from stories above and below converge at an intermediate level, the capacity of the means of egress from the point of convergence shall not be less than the sum of the required capacities for the two adjacent stories.
404 ATRIUMS 404.3 Automatic sprinkler protection. An approved automatic sprinkler system shall be installed throughout the entire building.
404.5 Smoke control. A smoke control system shall be installed in accordance with Section 909.
Exceptions: 1.
Exception: A fire barrier is not required where a glass wall forming a smoke partition is provided. The glass wall shall comply with all of the following: 1. Automatic sprinklers are provided along both sides of the separation wall and doors, or on the room side only if there is not a walkway on the atrium side. The sprinklers shall be located between 4 inches and 12 inches (102 mm and 305 mm) away from the glass and at intervals along the glass not greater than 6 feet (1829 mm). The sprinkler system shall be designed so that the entire surface of the glass is wet upon activation of the sprinkler system without obstruction; 1.1. The glass wall shall be installed in a gasketed frame in a manner that the framing system deflects without breaking (loading) the glass before the sprinkler system operates; and Where glass doors are provided in the glass wall, they shall be either self-closing or automatic-closing.
Exceptions: 2. Where the ceiling of the atrium is more than 55 feet (16 764 mm) above the floor, sprinkler protection at the ceiling of the atrium is not required. TYPES OF CONSTRUCTION (Arkansas Fire Prevention Code Volume II Building)
CONSTRUCTION TYPE: I-B TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) BUILDING ELEMENT Primary structural frame (see Section 202) Bearing walls f,g Exterior Interior Nonbearing walls and partitions Exterior Nonbearing walls and partitions e Interior Floor construction and associated secondary members (see Section 202) Roof construction and associated secondary members (see Section 202)
TYPE I A B a a 3 2 3a 3
2a 2
TYPE II Ad B 1 0 1 1
0 0
TYPE III Ad B 1 0 2 1
TYPE IV HT HT
2 0
2 1/HT
TYPE V Ad B 1 0 1 1
0 0
0
0
0
0
0
See Section 602.4.6
0
0
2
2
1
0
1
0
HT
1
0
11/2 b
1b,c
1
0c
1
0
HT
1b,c
0
FIRE AND SMOKE PROTECTION FEATURES (Arkansas Fire Prevention Code Volume II Building)See Fire Protection Drawings for more information
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 2 " WIDTH PROVIDED = 36"
9
2. 3.
TOILET
MECH EQUIPMENT ROOM
U
7
FIBER TELECOM
CR
MEANS OF EGRESS (Arkansas Fire Prevention Code Volume I Fire)
1003 GENERAL MEANS OF EGRESS 1003.3 Protruding objects. Protruding objects shall comply with the requirements of Sections 1003.3.1 through 1003.3.4. 1003.3.1 Headroom. Protruding objects are permitted to extend below the minimum ceiling height required by Section 1003.2 provided a minimum headroom of 80 inches (2032 mm) shall be provided for any walking surface, including walks, corridors, aisles and passageways. Not more than 50 percent of the ceiling area of a means of egress shall be reduced in height by protruding objects.
Checked by:
1 MAIL ROOM MAIN ELECTRICAL
9
2
Accessory storage areas, mechanical equipment room Business area Assembly (Unconcentrated) Mercantile
300 gross 100 gross 15 net 60 gross
Exception: Where approved by the building official , the actual number of occupants for whom each occupied space, floor or building is designed, although less than those determined by calculation, shall be permitted to be used in the determination of the design occupant load .
15 BUILDING OPERATIONS/ MECHANICS
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 0 " WIDTH PROVIDED =
TRAVEL DISTANCE: 135' < 300'
3
Drawn by:
MM
1005 EGRESS WIDTH 1005.1 Minimum required egress width. The means of egress width shall not be less than required by this section. 1005.3.1 Stairways. The capacity, in inches (mm), of means of egress stairways shall be calculated by multiplying the occupant load served by such stairway by a means of egress capacity factor of 0.3 inch (7.6 mm) per occupant. Where stairways serve more than one story, only the occupant load of each story considered individually shall be used in calculating the required capacity of the stairways serving that story. Exception: For other than Group H and I-2 occupancies, the capacity, in inches (mm), of means of egress stairways shall be calculated by multiplying the occupant load served by such stairway by a means of egress capacity factor of 0.2 inch (5.1 mm) per occupant in buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2 and an emergency voice/alarm communication system in accordance with Section 907.5.2.2.
DOOR TAG
1-HR RATED WALL 2-HR RATED WALL 3-HR RATED WALL
00 BASEMENT - LIFE SAFETY
2
1/16" = 1'-0"
EGRESS OCCUPANCY LOAD
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 24 " WIDTH PROVIDED = 72"
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 24 " WIDTH PROVIDED = 72"
160
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 5 " WIDTH PROVIDED = 72"
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 5 " WIDTH PROVIDED = 72"
ENCLOSED PATIO
32
BASEMENT LEVEL
45
FIRST FLOOR
611
SECOND FLOOR
430
THIRD FLOOR
399
FOURTH FLOOR
417
31
63
COVERED PATIO
PENTHOUSE LEVEL
TOTAL: FROM ABOVE
7.
In other than Group R-1 occupancies, the minimum widths shall not apply to interior egress doors within a dwelling unit or sleeping unit that is not required to be an Accessible unit, Type A unit or Type B unit. Door openings required to be accessible within Type B units shall have a minimum clear width of 31.75 inches (806 mm).
1008.1.1.1 Projections into clear width. There shall not be projections into the required clear width lower than 34 inches (864 mm) above the floor or ground. Projections into the clear opening width between 34 inches (864 mm) and 80 inches (2032 mm) above the floor or ground shall not exceed 4 inches (102 mm).
121
FROM BELOW DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 19 " WIDTH PROVIDED = 36" STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 25 " WIDTH PROVIDED = 44" DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 11 " WIDTH PROVIDED = 36"
TRAINING B USE GROUP A (ACCESSORY) AREA < 10%
50
108
50
USE GROUP A (ACCESSORY) AREA < 10%
NW STAIR 1
REF KITCHEN
121
54
VESTIBULE
8 71
STORAGE A
STORAGE B
1
1
51
51
78
160
NE STAIR 2
STORAGE
STORAGE
WOMENS TOILET
1
1
U
CONFERENCE
6
OFFICE WIRING CLOSET ELEC.
COPY
OFFICE
OFFICE
OFFICE
14
2
2
2
2
FEC2 MENS TOILET
2
U
U
CONFERENCE
U
10 27
9
18
12
12 OPEN WORKSTATION AREA
OPEN WORKSTATION AREA
Exist Access Travel Distance (w/Sprinkers) = 300'
11
38
1021 NUMBER OF EXITS AND CONTINUITY 1021.1 Exits from stories. All spaces within each story shall have access to the minimum number of approved independent exits as specified in Table 1021.1 based on the occupant load of the story . For the purposes of this chapter, occupied roofs shall be provided with exits as required for stories.
10
Exceptions:
18
34 11
9
Murphy USA
ATRIUM
TRAVEL DISTANCE: 125' < 300'
23 11
OFFICE
Exit access stairways and ramps that comply with Exception 3 or 4 of Section 1016.1 shall be permitted to provide the minimum number of approved independent exits required by Table 1021.1 on each story .
22 OFFICE
COPY
OFFICE
OFFICE
2
1
2
2
11
OFFICE
OFFICE
OFFICE
2
2
2
3 13 MENS TOILET
Minimum number of exits (per story) 2 3 4
7 FIRE AND SMOKE PROTECTION FEATURES 715.1 General. Joints installed in or between fire-resistance-rated walls, floor or floor/ceiling assemblies and roofs or roof/ceiling assemblies shall be protected by an approved fire-resistant joint system designed to resist the passage of fire for a time period not less than the required fire-resistance rating of the wall, floor or roof in or between which it is installed. Fire-resistant joint systems shall be tested in accordance with Section 715.3. Exception: Fire-resistant joint systems shall not be required for joints in all of the following locations: 1. Floors within a single dwelling unit. 2. Floors where the joint is protected by a shaft enclosure in accordance with Section 713. 3. Floors within atriums where the space adjacent to the atrium is included in the volume of the atrium for smoke control purposes. 4. Floors within malls. 5. Floors and ramps within open and enclosed parking garages or structures constructed in accordance with Sections 406.5 and 406.6, respectively. 6. Mezzanine floors. 7. Walls that are permitted to have unprotected openings. 8. Roofs where openings are permitted. 9. Control joints not exceeding a maximum width of 0.625 inch (15.9 mm) and tested in accordance with ASTM E 119 or UL 263.
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 15 " WIDTH PROVIDED = 36" STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 20 " WIDTH PROVIDED = 44" DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 12 " WIDTH PROVIDED = 36"
2
2
1016 EXIT ACCESS TRAVEL DISTANCE 1016.1 Travel distance limitations Exits shall be so located on each story such that the maximum length of exit access travel, measured from the most remote point within a story along the natural and unobstructed path of egress travel to an exterior exit door at the level of exit discharge, an entrance to a vertical exit enclosure, an exit passageway, a horizontal exit, an exterior exit stairway or an exterior exit ramp, shall not exceed the distances given in Table 1016.1.
Occupant Load 1-500 501-1,000 More than 1,000
90
75
82
OFFICE
4
2
54
FE
FEC1
MECH
1,908
100
DINING ROOM TRAINING A
Exception: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the floor.
3.
6
USE GROUP A (ACCESSORY) AREA < 10%
OFFICE
STORAGE
1
2
ELEVATOR 1
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 24 " WIDTH PROVIDED = 44"
MURPHY USA STORE
MECH
18
JAN.
47 34
83
58 9
FEC1
47
5
SE STAIR 4
LOBBY TOILET ROOM
106
U
81
34
CONFERENCE
CONFERENCE
CONFERENCE
CONFERENCE
VENDOR CONFERENCE
17
17
17
17
21
18
VENDOR CONFERENCE
37
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 8 " WIDTH PROVIDED = 36
128
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 13 " WIDTH PROVIDED = 36
CUSTOMER EXPERIENCE
4
01 FIRST FLOOR - LIFE SAFETY
13
57
102
Westlake Reed Leskosky
1
U
94
1/16" = 1'-0"
U
13
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 13 " WIDTH PROVIDED = 36
1
14
LOBBY OPEN WORKSTATION AREA
120
ELEC.
USE GROUP M (ACCESSORY) AREA < 10%
71
Commision # 15054.00 200 Peach Street El Dorado, AR 71730
3
U
27
U
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 18 " WIDTH PROVIDED = 36
2
ELEVATOR 2
U
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 11 " WIDTH PROVIDED = 36"
OFFICE
FILE/ WORK WIRING CLOSET
24
WOMENS TOILET
Maximum Design Occupant Load Basement - 7,811 GSF First Floor - 34,913 GSF Second Floor - 32,983 GSF Third Floor - 31,750 GSF Fourth Floor - 30,572 GSF Penthouse Level - 4,796 GSF
FIRE EXTINGUISHER IN CABINET
FEC
PRINT ROOM
FEC2
Checker
1004 OCCUPANT LOAD 1004.1 Design occupant load
FIRE EXTINGUISHER WALL MOUNTED WITH BRACKET
FE
ELEV. EQUIP.
Exception: Door closers and stops shall not reduce headroom to less than 78 inches (1981 mm). A barrier shall be provided where the vertical clearance is less than 80 inches (2032 mm) high. The leading edge of such a barrier shall be located 27 inches (686 mm) maximum above the floor.
CARD READER
CG
OFFICE
CHAPTER 10
EGRESS PATH OR EXIT
U
Width of door leaves in revolving doors that comply with Section 1008.1.4.1 shall not be limited.
Exterior door openings in dwelling units and sleeping units, other than the required exit door, shall not be less than 76 inches (1930 mm) in height.
CONVERGENCE LOAD
TRAVEL DISTANCE
Door openings to storage closets less than 10 square feet (0.93 m2) in area shall not be limited by the minimum width.
6.
OCCUPANT LOAD
STORAGE
Door openings to resident sleeping units in Group I-3 occupancies shall have a clear width of not less than 28 inches (711 mm).
Door openings within a dwelling unit or sleeping unit shall not be less than 78 inches (1981 mm) in height.
00
FE
U
The minimum and maximum width shall not apply to door openings that are not part of the required means of egress in Group R-2 and R-3 occupancies.
5.
UNOCCUPIED
RECEIVING
Exceptions: 1.
U
00 5
1008 DOORS, GATES AND TURNSTILES 1008.1.1 Size of doors. The minimum width of each door opening shall be sufficient for the occupant load thereof and shall provide a clear width of 32 inches (813 mm). Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear width of 32 inches (813 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches (813 mm). The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal. Means of egress doors in a Group I-2 occupancy used for the movement of beds shall provide a clear width not less than 411/2 inches (1054 mm). The height of door openings shall not be less than 80 inches (2032 mm).
8. CHAPTER 7
In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal exit and located at or above the levels of exit discharge.
Exceptions: 1. The clear width of 48 inches (1219 mm) between handrails is not required in buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2. 2. Areas of refuge are not required at stairways in buildings equipped throughout by an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2. 3. The clear width of 48 inches (1219 mm) between handrails is not required for stairways accessed from a horizontal exit. 4. Areas of refuge are not required at stairways serving open parking garages. 5. Areas of refuge are not required for smoke protected seating areas complying with Section 1028.6.2. 6. The areas of refuge are not required in Group R-2 occupancies.
4. For SI: 1 foot = 304.8 mm. a. Roof supports: Fire-resistance ratings of primary structural frame and bearing walls are permitted to be reduced by 1 hour where supporting a roof only. b. Except in Group F-1, H, M and S-1 occupancies, fire protection of structural members shall not be required, including protection of roof framing and decking where every part of the roof construction is 20 feet or more above any floor immediately below. Fire-retardant-treated wood members shall be allowed to be used for such unprotected members. c. In all occupancies, heavy timber shall be allowed where a 1-hour or less fire-resistance rating is required. d. An approved automatic sprinkler system in accordance with Section 903.3.1.1 shall be allowed to be substituted for 1-hour fire-resistancerated construction, provided such system is not otherwise required by other provisions of the code or used for an allowable area increase in accordance with Section 506.3 or an allowable height increase in accordance with Section 504.2. The 1-hour substitution for the fire resistance of exterior walls shall not be permitted. e. Not less than the fire-resistance rating required by other sections of this code. f. Not less than the fire-resistance rating based on fire separation distance (see Table 602). g. Not less than the fire-resistance rating as referenced in Section 704.10
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 2 " WIDTH PROVIDED = 44"
1007.3 Stairways. In order to be considered part of an accessible means of egress , an exit access stairway as permitted by Section 1016.1 or exit stairway shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor-level landing or shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit .
See Table 602 0
36
FIRE PUMP
404.6 Enclosure of atriums. Atrium spaces shall be separated from adjacent spaces by a 1-hour fire barrier constructed in accordance with Section 707 or a horizontal assembly constructed in accordance with Section 711, or both.
CHAPTER 6
LIFE SAFETY LEGEND
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 6 " WIDTH PROVIDED = 48"
1007 ACCESSIBLE MEANS OF EGRESS 1007.2.1 Elevators required. In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying with Section 1007.4.
404.4 Fire alarm system. A fire alarm system shall be provided in accordance with Section 907.2.14.
1.2.
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
19
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 19 " WIDTH PROVIDED = 36
VENDOR CONFERENCE
21
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 25 " WIDTH PROVIDED = 44"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
LIFE SAFETY PLANS
123
CD
G-100
12/1/2015 4:22:46 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
OFFICE
2 STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 19 " WIDTH PROVIDED = 44"
94
VP OFFICE
OFFICE
3
3
OFFICE
CONTROLLER
8
14
OFFICE
TREASURY
2
9 DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 15 " WIDTH PROVIDED = 36"
80
EXPANSION
2
FILES/ WORK
CHECK ROOM NW STAIR 1
NE STAIR 2
3
2 94
AUDIT
OFFICE
6
2
CORRIDOR
26
U
ROOF
26
26
FILE/ WORK
OUTSIDE AUDITORS
3
9
1
WOMENS TOILET TEAMING
CONFERENCE
COPY
OFFICE
OFFICE
OFFICE
21
11
2
2
2
2
COFFEE/ KITCHEN
U
FEC2
MECH
2 53
ELEC.
CATWALK
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 12 " WIDTH PROVIDED = 36"
10
37
37
MENS TOILET
54
WIRING CLOSET
CONFERENCE
U
13
U
UNOCCUPIED
00
OCCUPANT LOAD
00
U
U CONFERENCE
LIFE SAFETY LEGEND
80
REF
COMM.
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 16 " WIDTH PROVIDED = 44"
CONVERGENCE LOAD
17
13
VP OFFICE
EGRESS PATH OR EXIT
CATWALK
CATWALK
3 OFFICE
17
2
HSSE
10 ROOF
OFFICE
2
OFFICE
OFFICE
2
2
ROOF
OPEN TO BELOW
TRAVEL DISTANCE OFFICE OF THE CEO
OPEN TO BELOW
16
COPY
CR
12
OFFICE
2
2 32
OFFICE
WIRING CLOSET
16
2
FIRE EXTINGUISHER WALL MOUNTED WITH BRACKET
FE
CONFERENCE
INSURANCE
CARD READER
U
17
FIRE EXTINGUISHER IN CABINET
FEC
7 CONFERENCE
17 ELEVATOR 1
ELEVATOR 2
ELEVATOR 1 MENS TOILET
ELEVATOR PENTHOUSE
MECH
U
MECH
U
6
STORAGE -1
U
FEC2
U STORAGE-2
79
11
3
92
ELEC.
6 EXECUTIVE VISITING
OFFICE WOMENS TOILET
59
COPY
TOILET
1
U
1
120
1-HR RATED WALL JAN
TOILET
2-HR RATED WALL
U
A/V ROOM
U
2
LEGAL
3-HR RATED WALL
83
MEETING CONFERENCE
6
13
13
35
EXECUTIVE
SE STAIR 4
16
CONFERENCE
15 STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 24 " WIDTH PROVIDED = 44"
1
3
118
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 18 " WIDTH PROVIDED = 36"
ROOF
FE
35
120
EXECUTIVE BOARDROOM
OFFICE
OFFICE
OFFICE
CONFERENCE
4
4
5
22
WET BAR
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 19 " WIDTH PROVIDED = 36" STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 25 " WIDTH PROVIDED = 44"
123
70 OFFICE
1
3
4
05 PENTHOUSE FLOOR - LIFE SAFETY PLAN
3
1/16" = 1'-0"
DOOR TAG
MECH
KITCHEN
2
U 28
U
PENTHOUSE STAIR
3
OFFICE
2
FE
59
STORAGE
3
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 0 " WIDTH PROVIDED =
ELEVATOR 2
TRAVEL DISTANCE: 165' < 300'
04 FOURTH FLOOR - LIFE SAFETY 1/16" = 1'-0"
EGRESS OCCUPANCY LOAD BASEMENT LEVEL
45
FIRST FLOOR
611
SECOND FLOOR
430
THIRD FLOOR
399
FOURTH FLOOR
417
PENTHOUSE LEVEL
TOTAL:
DIRECTOR'S OFFICE
2
2
2
2
DIRECTOR'S OFFICE
MANAGER'S OFFICE
DIRECTOR'S OFFICE
2
2
2
DIRECTOR'S OFFICE
DIRECTOR'S OFFICE
NW STAIR 1
25
2 116
80
75
25
NE STAIR 2
2
50
6
35
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 20 " WIDTH PROVIDED = 44"
75
1 MERCHANDISE DISPLAY AREA
18
MECH
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 12 " WIDTH PROVIDED = 36"
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 15 " WIDTH PROVIDED = 36"
COFFEE/ KITCHEN
SR. DIRECTOR'S OFFICE
2
NW STAIR 1
100
FEC2 TEAMING
19
GUEST OFFICE
6
OPEN WORKSTATION AREA
17
TEAMING
MANAGER OFFICE
OPEN WORKSTATION AREA
2
34
2
SR. DIRECTOR'S OFFICE
17
SR. DIRECTOR'S OFFICE
2
FILES/ STORAGE
1
20
OPEN TO BELOW 16
10
TEAMING
WOMENS TOILET
DATA CENTER
2
U
11
MANAGER'S OFFICE
MENS TOILET
51
U
TEAMING
TEAMING
4
22
18
OPEN WORKSTATION AREA
OPEN TO BELOW
16
21
16
32
2
SR. DIRECTOR'S OFFICE
Commision # 15054.00 200 Peach Street El Dorado, AR 71730
2 TEAMING
3
CONFERENCE
22
2
TRAVEL DISTANCE: 125' < 300'
ELEVATOR 2
MENS TOILET
SR. MANAGER'S OFFICE
18
MANAGER'S OFFICE
U ELEVATOR 1
CONFERENCE
VP OFFICE
3
WIRING CLOSET
2
Murphy USA
TEAMING
2 SR. VP OFFICE
DIRECTOR'S OFFICE
36
11
DIRECTOR'S OFFICE
2
CONFERENCE
17
WIRING CLOSET
U
Westlake Reed Leskosky
ELEVATOR 2
ELEVATOR 1
MENS TOILET
54
55
FEC2
ELEC.
U
ADMINISTRATIVE ASSISTANT
1
TEAMING
1
6
2
COFFEE
2
2
MANAGER'S OFFICE
REF
U
MECH
FEC1
SR. DIRECTOR' S OFFICE
2
2
42
U FEC2
U
WOMENS TOILET
53
35 1
ADMINISTRATIVE ASSISTANT
2
JAN
WOMENS TOILET
TEAMING
U
U
16
FEC1
106
51
45
2
103
102 COPY
MANAGER'S OFFICE
2
106
18
26
51
1
25 VP OFFICE
HUDDLE SR. MANAGER'S OFFICE
5
10
SE STAIR 4
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 16 " WIDTH PROVIDED = 36"
2
102
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 21 " WIDTH PROVIDED = 44"
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 21 " WIDTH PROVIDED = 44"
3
103
02 SECOND FLOOR - LIFE SAFETY 1/16" = 1'-0"
ELEC.
72
U
DIRECTOR'S OFFICE
MECH
1
2 COPY
1
29
FILES/ STORAGE
JAN
2
U
28
56
121
48 DIRECTOR'S OFFICE
OPEN WORKSTATION AREA
28
2 OPEN TO BELOW
SE STAIR 4
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 19 " WIDTH PROVIDED = 36"
2 DIRECTOR'S OFFICE
11
2
1
1
30
TEAMING
DIRECTOR'S OFFICE
5
2
03 THIRD FLOOR - LIFE SAFETY
45
2
FEC1
COATS
DIRECTOR'S OFFICE
SR. DIRECTOR'S OFFICE
OPEN WORKSTATION AREA
MANAGER'S OFFICE
2
1
ENGINEERING CONFERENCE
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 16 " WIDTH PROVIDED = 36"
1
KITCHEN
COATS
MM
106
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 16 " WIDTH PROVIDED = 36"
10
19
Drawn by:
55 FILE/ STORAGE
SR. DIRECTOR'S OFFICE
16
1/16" = 1'-0"
45
NE STAIR 2
GUEST OFFICE
10
32
2
UP
11
CONFERENCE
Checked by:
7
2
1
2
14
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 22 " WIDTH PROVIDED = 44"
9
41
17
22
28
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 16 " WIDTH PROVIDED = 36"
2
2
MANAGER'S OFFICE
U
CONFERENCE
OPEN WORKSTATION AREA
19
HUDDLE
17
UP
35
2
TEAMING
WIRING CLOSET
U
14
41
58
ELEC.
11
3
Checker
MENS TOILET
U
WIRING CLOSET
TRAVEL DISTANCE: 133' < 300'
2
PRIVACY
2
40
VP OFFICE
2
FIRE DATA CENTERDATA CENTER SUPPRESSION UPS STORAGE VALVE
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 22 " WIDTH PROVIDED = 44"
106
2
1
FEC1
U
SR. MANAGER'S OFFICE
2
MECH
36 ELEC.
24
48
GUEST OFFICE
U
3
2
1
2
WOMENS TOILET SR. MANAGER'S OFFICE
REF
4
OPEN WORKSTATION AREA
24
100
COPY
CONFERENCE
SR. DIRECTOR'S OFFICE
COPY
SR. MANAGER'S OFFICE
OPEN WORKSTATION AREA
2
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 15 " WIDTH PROVIDED = 44"
1,908
FEC2
SR. DIRECTOR'S OFFICE
FEC1
DOOR REQ. WIDTH (PER 1005.1) OL x .15 = 18 " WIDTH PROVIDED = 36"
116
MANAGER'S OFFICE
REF
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 24 " WIDTH PROVIDED = 44"
DIRECTOR'S OFFICE
6
121
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
LIFE SAFETY PLANS
STAIR REQ. WIDTH (PER 1005.1) OL x .2 = 25 " WIDTH PROVIDED = 44"
TEAMING
11
CD
G-101
12/1/2015 4:26:13 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
GENERAL NOTES - DEMOLITION 1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE. 7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
U
KEYNOTES
0.0 D.004 DN D.007
##.###
DEMO CMU WALL - ALLOW FOR NEW CMU TO BE TOOTHED-IN AND SALVAGE 10" HIGH HEADER BLOCKS FOR RE-USE IF PRACTICAL. REMOVE PORTION OF CONCRETE REQUIRED FOR NEW STRUCTURAL WORK - SEE STRUC.
SERVICE DOCK
DEMOLITION PLAN LEGEND 0.8 1
CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
2
FIRE PUMP
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
3
4
RECEIVING 5
B01
STG.
STAIRS S-01
MECH. EQUIPMENT ROOM
B14
UP
B02
6
7
STG. 8
B05
9
D.004
ELEV #3
10
TELEPHONE EQUIPMENT ROOM
LAB
BUILDING SUPPLY
B07
B04
B10
ELEV MACH RM
CORR.
B08
B06
11
D.004
12
13
ELECT. ROOM
D.004
14
B09
STORAGE RM - 1
15
Murphy USA
B11
16
VAULT 17
Checker
B03
18
Commision #15054.00 200 Peach Street El Dorado, AR 71730
D.007
Checked by:
19
Westlake Reed Leskosky
20 The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
Drawn by:
Author
BASEMENT DEMO PLAN 1
BASEMENT DEMO PLAN 1/8" = 1'-0"
CD
AD-100
12/1/2015 4:26:23 PM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
E.027
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
D.036
D.036
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
D.036
0.0
DEMOLITION PLAN LEGEND
D.036 D.010 D.012
DN
DN
D.011
D.013
CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
D.012
D.041
D.013 D.011
D.011
D.039
GENERAL NOTES - DEMOLITION
D.012
E.025 D.012
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
D.041
D.030
D.030
D.045
D.045
D.041
D.041
D.030
D.030
D.030
0.8 1 D.009
D.009
D.010
D.009
2 D.011
D.041 D.011
3
4
5 D.003
UP
UP
NW STAIR 1
6
NE STAIR 2
S-1
DN
S-2
7
2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE.
8
7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
9
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
D.003
D.018
NW CORE #1
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN.
KEYNOTES
D.001
ELEV #3
10 D.017
C-1
NE CORE #2 C-2
D.037
D.001
PERIMETER WALLS AND CENTRAL PLUMBING CHASE WALLS TO REMAIN. REMOVE ALL OTHER COMPONENTS OF THE RESTROOMS INCLUDING FLOORING, TOILET PARTITIONS, PLUMBING FIXTURES, HARDWARE, ACCESSORIES, MIRRORS, COUNTERTOPS, CEILINGS, LIGHTING, DIFFUSERS, WALL TILE, WALLCOVERINGS, ETC.
D.002
REMOVE EXISTING FOUNTAINS AND PLANTERS AT CENTRAL ATRIUM REMOVE EXISTING VESTIBULE WALL AND GLASS SLIDING DOORS MONUMENTAL STAIR - REMOVE ALL FLOOR THINSET TILE, LINEAR METAL SOFFIT/CEILING AND OUTER GLASS RAILING. INNER GLASS RAILING TO REMAIN. REMOVE PORTION OF CONCRETE REQUIRED FOR NEW STRUCTURAL WORK - SEE STRUC. REMOVE EXISTING WINDOW SYSTEM REMOVE EXISTING THINSET TILE REMOVE EXSTING SLAB ON GRADE REMOVE EXISTING PIPE RAILINGS REMOVE EXISTING STAIR REMOVE EXISTING DRINKING FOUNTAIN MODULE SLAB ON GRADE TRENCHING AS REQUIRED FOR ADDITION OF SANITARY LINES TO EXISTING SYSTEM. NOTIFY ARCHITECT OF CONFLICTS WITH EXISTING POWER/DATA FLOOR DISTRIBUTION - SEE PLUM. REMOVE EXISTING DOOR - RETAIN EXISTING DOOR FRAME REMOVE EXISTING RECEPTION DESK REMOVE EXISTING STONE SILL. REMOVE EXISTING FLOOR DRAIN REMOVE AND SALVAGE DOOR AND FRAME AND REMOVE ADJACENT WALLS TO ALLOW FOR NEW AHU SAW CUT 2" FROM TOP OF EXISTING RETAINING WALL TO ALLOW FOR GRANITE CAP SHAFT TO BE FILLED IN. SEE STRUCT. DWGS REMOVE PORTION OF EXISTING RETAINING WALL - SEE STRUC. REMOVE PORTION OF EXISTING CONSTRUCTION REQUIRED TO ALLOW FOR POWER/DATA DROPS. SAW CUT PORTION OF EXISTING STONE SILL TO ACCOmmODATE NEW EXTERIOR DOOR. REFLASH AND SEAL AS REQUIRED AT CUT END. SALVAGE STONE PANEL CLADDING. REINSTALL IN NEW LOCATION. EXISTING COMPOSITE DECK TO REMAIN SALVAGE EXISTING FLOOR DRAIN. REINSTALL IN SAME LOCATION IN NEW SLAB ON GRADE.
11
D.040
12 D.001
ELEC. CL.
D.003
13
14 D.006
15
16
17
18
19
D.001 D.021
D.006
D.007 D.009 D.010 D.011 D.012 D.013 D.017 D.018
D.021 D.022 D.030 D.036 D.037 D.039 D.040 D.041
20
D.042 D.045
D.002
21 E.023
22
##.###
E.025 E.027
D.007
23
24
25
ELEV #1
ELEV #2 ELEC.
26
D.040
SE CORE #4
SW CORE #3
SLAB DEMO FOR STORE (N.I.C.)
C-3
27
C-4
D.017 D.037
D.022
28
Murphy USA
JAN.
D.001
29
Checker
30 D.018
31
Commision #15054.00 200 Peach Street El Dorado, AR 71730
D.003
SW STAIR 3
SE STAIR 4
Checked by:
S-3 UP
UP
S-4
32
E.023
Westlake Reed Leskosky
33 D.003
35
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
36
FIRST FLOOR DEMO PLAN
34
Author
D.042
D.042
37
Drawn by:
CD 1
FIRST FLOOR DEMO PLAN 1/8" = 1'-0"
AD-101
12/1/2015 4:26:33 PM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
0.0
GENERAL NOTES - DEMOLITION
0.8 1
2
3
4
5
NE STAIR 2 UP
UP S-2
NW STAIR 1 DN
6
DN
S-1
7 UP
UP
8
9
D.001
NW CORE #1
ELEV #3
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE. 7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS. 8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
10 D.017
KEYNOTES
##.###
NE CORE #2
C-1 D.040
C-2
D.037
D.001
PERIMETER WALLS AND CENTRAL PLUMBING CHASE WALLS TO REMAIN. REMOVE ALL OTHER COMPONENTS OF THE RESTROOMS INCLUDING FLOORING, TOILET PARTITIONS, PLUMBING FIXTURES, HARDWARE, ACCESSORIES, MIRRORS, COUNTERTOPS, CEILINGS, LIGHTING, DIFFUSERS, WALL TILE, WALLCOVERINGS, ETC.
D.006
MONUMENTAL STAIR - REMOVE ALL FLOOR THINSET TILE, LINEAR METAL SOFFIT/CEILING AND OUTER GLASS RAILING. INNER GLASS RAILING TO REMAIN. REMOVE EXISTING DRINKING FOUNTAIN MODULE REMOVE EXISTING RAILING AT ATRIUM SAW CUT EXISTING SLAB ON METAL DECK TO ALLOW FOR NEW COLUMN CONNECTIONS. COORDINATE REQUIREMENTS WITH STRUCTURAL CONNECTION DETAILS FOR EACH LOCATION. REMOVE AND SALVAGE DOOR AND FRAME AND REMOVE ADJACENT WALLS TO ALLOW FOR NEW AHU SHAFT TO BE FILLED IN. SEE STRUCT. DWGS SAW CUT EXISTING CONCRETE SLAB ON METAL DECK FOR NEW SHAFT - SEE MECH.
11
12 D.001
ELEC. CL.
13
D.017 D.023 D.029
14 D.037
15
D.040 D.044
16
DEMOLITION PLAN LEGEND 17 D.006
CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
18
19 DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
20
21 D.023
D.029 TYP.
22
23
24
25
ELEV #1
ELEV #2
D.001
ELEC.
26
SE CORE #4
SW CORE #3 D.040 C-3
27
C-4
D.017 D.037
28
Murphy USA
JAN.
D.001
D.044
29
Checker
30
31 DN
DN
Checked by:
SW STAIR 3 UP
Commision #15054.00 200 Peach Street El Dorado, AR 71730
S-3
SE STAIR 4 S-4
32
UP
Westlake Reed Leskosky
33
34
35
Author
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
SECOND FLOOR DEMO PLAN
37
Drawn by:
CD 1
SECOND FLOOR DEMO PLAN 1/8" = 1'-0"
AD-102
12/1/2015 4:26:43 PM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
GENERAL NOTES - DEMOLITION
0.8 1
2
3
4
5
NE STAIR 2 UP
UP
NW STAIR 1 DN
6
S-2 DN
S-1
7
D.001
NW CORE #1
ELEV #3
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE.
8
7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
9
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
KEYNOTES
10 D.017
C-1
NE CORE #2
D.001
PERIMETER WALLS AND CENTRAL PLUMBING CHASE WALLS TO REMAIN. REMOVE ALL OTHER COMPONENTS OF THE RESTROOMS INCLUDING FLOORING, TOILET PARTITIONS, PLUMBING FIXTURES, HARDWARE, ACCESSORIES, MIRRORS, COUNTERTOPS, CEILINGS, LIGHTING, DIFFUSERS, WALL TILE, WALLCOVERINGS, ETC.
12
D.006
13
D.017 D.023 D.029
MONUMENTAL STAIR - REMOVE ALL FLOOR THINSET TILE, LINEAR METAL SOFFIT/CEILING AND OUTER GLASS RAILING. INNER GLASS RAILING TO REMAIN. REMOVE EXISTING DRINKING FOUNTAIN MODULE REMOVE EXISTING RAILING AT ATRIUM SAW CUT EXISTING SLAB ON METAL DECK TO ALLOW FOR NEW COLUMN CONNECTIONS. COORDINATE REQUIREMENTS WITH STRUCTURAL CONNECTION DETAILS FOR EACH LOCATION. REMOVE AND SALVAGE DOOR AND FRAME AND REMOVE ADJACENT WALLS TO ALLOW FOR NEW AHU SHAFT TO BE FILLED IN. SEE STRUCT. DWGS SAW CUT EXISTING CONCRETE SLAB ON METAL DECK FOR NEW SHAFT - SEE MECH.
D.040 C-2
D.037
11
D.001
ELEC. CL.
##.###
14 D.037
15
16
D.040 D.044
DEMOLITION PLAN LEGEND
17
CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
D.006
18
19
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
20
21 D.029 D.023
22
23
24
25
ELEV #1
ELEV #2
D.001
ELEC.
26
SE CORE #4
SW CORE #3 D.040
C-3
27
C-4
D.017 D.037
28
Murphy USA
JAN.
D.001
D.044
29
Checker
30
31 DN
DN
Checked by:
SW STAIR 3 UP
S-3
SE STAIR 4 S-4
32
UP
Westlake Reed Leskosky
33
35
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
36
THIRD FLOOR DEMO PLAN
Author
34
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
37
CD 1
THIRD FLOOR DEMO PLAN 1/8" = 1'-0"
AD-103
12/1/2015 4:26:53 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW 0.0
GENERAL NOTES - DEMOLITION
0.8 1
2
3
4
5
NW STAIR 1
NE STAIR 2
S-1
6
S-2 DN
DN
7
8
9
D.001
NW CORE #1
ELEV #3
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE. 7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS. 8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
KEYNOTES
10 D.017
C-1
NE CORE #2
D.040
C-2
D.037
D.001
PERIMETER WALLS AND CENTRAL PLUMBING CHASE WALLS TO REMAIN. REMOVE ALL OTHER COMPONENTS OF THE RESTROOMS INCLUDING FLOORING, TOILET PARTITIONS, PLUMBING FIXTURES, HARDWARE, ACCESSORIES, MIRRORS, COUNTERTOPS, CEILINGS, LIGHTING, DIFFUSERS, WALL TILE, WALLCOVERINGS, ETC.
D.006
MONUMENTAL STAIR - REMOVE ALL FLOOR THINSET TILE, LINEAR METAL SOFFIT/CEILING AND OUTER GLASS RAILING. INNER GLASS RAILING TO REMAIN. REMOVE EXISTING DRINKING FOUNTAIN MODULE REMOVE EXISTING RAILING AT ATRIUM REMOVE EXISTING COUNTERTOPS REMOVE EXISTING BATHROOM FINISHES REMOVE AND SALVAGE DOOR AND FRAME AND REMOVE ADJACENT WALLS TO ALLOW FOR NEW AHU SHAFT TO BE FILLED IN. SEE STRUCT. DWGS SAW CUT EXISTING CONCRETE SLAB ON METAL DECK FOR NEW SHAFT - SEE MECH. SALVAGE CUSTOM RECESSED DOOR AND FRAME ASSEMBLY .DISMANTLE AND REASSEMBLE IN NEW LOCATION.
11
12 D.001
ELEC. CL.
13
14
15
D.017 D.023 D.024 D.027 D.037 D.040 D.044 E.014
16
##.###
DEMOLITION PLAN LEGEND 17 D.006
CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
18
19 DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
20 D.023
21
22
23
24
25
ELEV #1
ELEV #2
D.001
ELEC.
26
D.024
SW CORE #3
SE CORE #4
D.027
STORAGE
D.040
C-3
COPY
EXECUTIVE KITCHEN
C-4
D.017
PENTHOUSE STAIR
D.024
D.001
D.024
D.027
28
JAN.
D.044
S-6
MEETING ROOM
31
4' - 4"
Checked by:
SW STAIR 3
29
30
EXECUTIVE DN
Murphy USA
A/V ROOM
D.024
D.024
Checker
D.037
UP
EXECUTIVE OFFICE
27
Commision #15054.00 200 Peach Street El Dorado, AR 71730
DN
EXECUTIVE MEETING ROOM
SE STAIR 4
S-3
32
S-4
Westlake Reed Leskosky
E.014
33
EXECUTIVE BOARDROOM D.024 D.024
EXECUTIVE OFFICE
EXECUTIVE OFFICE
EXECUTIVE OFFICE
MEETING ROOM
34
35
Author
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FOURTH FLOOR DEMO PLAN
37
Drawn by:
CD 1
FOURTH FLOOR DEMO PLAN 1/8" = 1'-0"
AD-104
12/1/2015 4:27:02 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - DEMOLITION
0.8 1
2
3
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC.
4
4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN).
5
5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE.
6
7
6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE.
8
7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
9
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
10
KEYNOTES
11 D.043
12
13
D.044
##.###
REMOVE EXISTING LOUVER FOR NEW LOUVER REPLACEMENT - SEE ROOF PLAN AND MECH. SAW CUT EXISTING CONCRETE SLAB ON METAL DECK FOR NEW SHAFT - SEE MECH.
DEMOLITION PLAN LEGEND
14 CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
15
16
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
17
18
19
20
21
22
23
24 D.043
D.043
25
26
STORAGE-2 P-05
MECH P-04
ELEVATOR PENTHOUSE P-03
MECH 27
P-02
STORAGE -1 P-01
28
DN
D.044
29
Murphy USA
Checker
30
31
Commision #15054.00 200 Peach Street El Dorado, AR 71730
32
Checked by:
Westlake Reed Leskosky 33
34
35
Author
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
PENTHOUSE DEMO PLAN
37
Drawn by:
CD 1
PENTHOUSE FLOOR DEMO PLAN 1/8" = 1'-0"
AD-105
12/1/2015 4:27:10 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
GENERAL NOTES - DEMOLITION 1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE. 7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS. 8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
KEYNOTES
##.###
0.0
DEMOLITION PLAN LEGEND CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
0.8
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
1
2
3
4
RECEIVING 5
B01
STG.
STAIRS S-01
MECH. EQUIPMENT ROOM
B14
B02
6
7
STG. 8 B05
9
10
TELEPHONE EQUIPMENT ROOM
BUILDING SUPPLY
B07
B10
ELEV MACH RM
CORR.
B08
B06
11
LAB 12
B04
13
ELECT. ROOM 14
B09
STORAGE RM - 1
Murphy USA
15
Checker
B11
16
VAULT B03
17
Checked by:
Westlake Reed Leskosky 18
19
Author
20
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
BASEMENT DEMO REFLECTED CEILING PLAN 1
00 BASEMENT EXISTING REFLECTED CEILING PLAN 1/8" = 1'-0"
CD
AD-120
12/1/2015 4:27:26 PM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
GENERAL NOTES - DEMOLITION
D.031
D.020
D.020
D.020 D.031
D.031
D.031
0.8 1
2
D.015
3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC.
4
4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN).
5
5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE.
7
8
9
ELEV #3
2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE).
3
6
NW CORE #1
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN.
6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE. 7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS. 8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
10
KEYNOTES
NE CORE #2
C-1
C-2
11
12
ELEC. CL.
D.015 D.016 D.020 D.031 D.035
##.###
REMOVE EXISTING LINEAR METAL CEILING / SOFFIT REMOVE EXISTING SUSPENDED GYPSUM CEILING REMOVE EXTERIOR STONE PANEL CLADDING REMOVE EXISTING STUCCO SOFFIT AND LIGHT FIXTURES REMOVE EXISTING LIGHT FIXTURES. PATCH AND REPAIR STUCCO SOFFIT - TYP.
13
DEMOLITION PLAN LEGEND 14 CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
15 D.035
16 DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
D.035
17 D.015
18
19
20
21 D.035 D.016
22
D.016
D.035
23
24
25
ELEV #1
ELEV #2 ELEC.
26
SE CORE #4
SW CORE #3
27
D.016 C-4
C-3
28
D.015
JAN.
29
Murphy USA
30
Checker
D.016
31
Checked by:
32 D.015
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
33
34
35
Author
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FIRST FLOOR DEMO REFLECTED CEILING PLAN
37
Drawn by:
D.015
1
01 FIRST FLOOR EXISTING REFLECTED CEILING PLAN 1/8" = 1'-0"
CD
AD-121
12/1/2015 4:27:42 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - DEMOLITION
D.035
D.035
D.035
0.8 1
2
3.9
3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC.
4
4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN).
5
5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE.
7
6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE.
8
7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
9
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
6
S-2
S-1
NW CORE #1
ELEV #3
2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE).
3
NE STAIR 2 NW STAIR 1
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN.
KEYNOTES
10
##.###
NE CORE #2
C-1
C-2
11
D.015 D.031 D.035
REMOVE EXISTING LINEAR METAL CEILING / SOFFIT REMOVE EXISTING STUCCO SOFFIT AND LIGHT FIXTURES REMOVE EXISTING LIGHT FIXTURES. PATCH AND REPAIR STUCCO SOFFIT - TYP.
12
ELEC. CL.
DEMOLITION PLAN LEGEND 13 CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
14
15 DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
16 D.035
D.035
17 D.015
18
19
20
21
22 D.035
D.035
23
24
25
ELEV #1
ELEV #2 ELEC.
26
SW CORE #3
SE CORE #4
C-3
C-4
27
28
JAN.
29
Murphy USA
Checker
30
Checked by:
31
SW STAIR 3
SE STAIR 4
S-3
S-4
32
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
33
34
35 D.015
Author
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
SECOND FLOOR DEMO REFLECTED CEILING PLAN
37
Drawn by:
D.035
1
02 SECOND FLOOR EXISTING REFLECTED CEILING PLAN 1/8" = 1'-0"
D.031
D.035
CD
AD-122
12/1/2015 4:27:59 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - DEMOLITION
D.035
D.035
D.035
0.8 1
2
3 3.9
4
5
NE STAIR 2 NW STAIR 1
6
S-2
S-1
7
NW CORE #1
ELEV #3
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE). 3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC. 4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN). 5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE.
8
7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
9
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
10
KEYNOTES
##.###
NE CORE #2
C-1
C-2
11
12
ELEC. CL.
D.015 D.035
REMOVE EXISTING LINEAR METAL CEILING / SOFFIT REMOVE EXISTING LIGHT FIXTURES. PATCH AND REPAIR STUCCO SOFFIT - TYP.
DEMOLITION PLAN LEGEND
13 CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
14
15
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
D.035
16 D.035
17 D.015
18
19
20
21 D.035
22 D.035
23
24
25
ELEV #1
ELEV #2 ELEC.
26
SW CORE #3
SE CORE #4
C-3
C-4
27
28
JAN.
29
Murphy USA
Checker
30
Checked by:
31
SW STAIR 3
SE STAIR 4
S-3
S-4
32
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
33
34
35
Author
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
THIRD FLOOR DEMO REFLECTED CEILING PLAN
37
Drawn by:
D.035
1
03 THIRD FLOOR EXISTING REFLECTED CEILING PLAN 1/8" = 1'-0"
D.035
D.035
CD
AD-123
12/1/2015 4:28:14 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - DEMOLITION D.035
D.035
D.035
D.035
D.035
0.8 1
2
3.9
NW STAIR 1
NE STAIR 2
S-1
S-2
3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC.
4
4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN).
5
5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE.
6
ELEV #3
2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE).
3
7
NW CORE #1
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN.
6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE.
8
7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS.
9
8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
10
KEYNOTES
##.###
NE CORE #2
C-1
C-2
11
12
D.014 D.016 D.028 D.031 D.035
ELEC. CL. D.038
13
14
15
E.006 E.013 E.014
REMOVE EXISTING SUSPENDED ACOUSTIC TILE CEILING REMOVE EXISTING SUSPENDED GYPSUM CEILING REMOVE EXISTING CEILING TILES - CEILING GRID TO REMAIN REMOVE EXISTING STUCCO SOFFIT AND LIGHT FIXTURES REMOVE EXISTING LIGHT FIXTURES. PATCH AND REPAIR STUCCO SOFFIT - TYP. REMOVE WOOD VENEER ON SOFFIT. PATCH WITH GWB AND PAINT TO MATCH EXISTING CEILING TO REMAIN WOOD PANEL AT DOOR FRAME TO REMAIN SALVAGE CUSTOM RECESSED DOOR AND FRAME ASSEMBLY .DISMANTLE AND REASSEMBLE IN NEW LOCATION.
DEMOLITION PLAN LEGEND
16 CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
D.035
D.035
17
18
OPEN TO ABOVE
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
19
20
21
22 D.035
D.035
23
24
25
ELEV #1
ELEV #2 ELEC.
26
SE CORE #4
SW CORE #3 STORAGE
C-3
COPY
E.006
D.028
EXECUTIVE OFFICE
TOILET D.028
EXECUTIVE KITCHEN
27
C-4
E.006
28
D.031
A/V ROOM
PENTHOUSE STAIR
JAN.
S-6
29
Murphy USA
D.014
D.014
TOILET 30
Checker
D.028 D.028
EXECUTIVE
MEETING ROOM EXECUTIVE MEETING ROOM
Checked by:
SW STAIR 3
E.006
31
D.038
SE STAIR 4
S-3
32
S-4 E.014
Westlake Reed Leskosky
E.013
33 D.028
EXECUTIVE OFFICE D.016
EXECUTIVE OFFICE
EXECUTIVE OFFICE
D.016
34
EXECUTIVE BOARDROOM
D.028
MEETING ROOM
35
D.016
36 E.006 E.006
Author Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FOURTH FLOOR DEMO REFLECTED CEILING PLAN
37 D.035
1
04 FOURTH FLOOR EXISTING REFLECTED CEILING PLAN 1/8" = 1'-0"
D.035
D.035
D.035
D.035
CD
AD-124
12/1/2015 5:57:17 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT 0.0
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - DEMOLITION 0.8 1
2
3 3.9
1. TOTAL INTERIOR GUT AND REMODEL. REMOVE ALL INTERIOR PARTITIONS, DOORS & HARDWARE, WINDOWS, ATRIUM RAILINGS, TOILET PARTITIONS/ ACCESSORIES, PLUMBING FIXTURES, MILLWORK/ CASEWORK, CEILINGS, LIGHTING, BRANCH DUCTWORK, DIFFUSERS, CONDUITS, PIPING, FLOOR FINISHES, CABLING, ETC. UNLESS NOTED HEREIN. 2. PORTIONS OF CORE ELEMENTS ARE TO BE RETAINED SUCH AS, THE FOUR EXIT STAIRS AND RAILINGS, THE THREE ELEVATORS AND SHAFTS, THE MONUMENTAL STAIR AT ATRIUM, THE CORE MECHANICAL, ELECTRICAL & JANITORIAL ROOMS, THE PERIMETER WALLS OF THE RESTROOMS, THE PENTHOUSE ROOMS AND THE GYPSUM BOARD ENCLOSURE AT INTERIOR COLUMNS (SHOWN HALF-TONE).
4
3. ALL FINISHES IN THESE CORE SPACES ARE TO BE REMOVED TO STRUCTURE IN PREPARATION FOR NEW FINISHES THROUGHOUT, INCLUDING ELEVATOR CAB FINISHES, ETC.
5
4. REMOVE ALL ADHESIVES AND RESIDUE FROM FLOORING FINISHES, PATCH AND GRIND CONCRETE SLABS SMOOTH TO PREPARE FOR NEW FINISHES (EXISTING UTILITY TRENCHES TO REMAIN).
6
7
8
9
10
5. PATCH AND RESURFACE ALL EXISTING GYPSUM WALLBOARD SURFACES AT INTERIOR OF BUILDING PERIMETER, OUTSIDE FACE OF BUILDING CORES, AND AT ALL COLUMNS UNLESS NOTED OTHERWISE. 6. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS DOOR RECESSED HINGES AND CLOSERS INCLUDING REVOLVING DOORS. NOTIFY ARCHITECT OF ANY CONFLICTS SUCH AS POWER/DATA TRENCH LOCATIONS. COORDINATE LOCATIONS AND REQUIREMENTS WITH FLOOR PLAN AND DOOR/HARDWARE SCHEDULE. 7. EXISTING POWER/DATA FLOOR RACEWAYS MUST BE SEALED OFF COMPLETELY USING COMPATIBLE CLOSURE PLATES PER MANUF. REQUIREMENTS PRIOR TO ANY ADJACENT CONCRETE PATCH POURS. 8. ALL EXISTING ATRIUM PLANTERS INCLUDING ASSOCIATED DRAINS ARE TO BE DEMOLISHED. FLOOR TO BE PATCHED TO MAINTAIN 2 HR. RATING - SEE PLUM. DEMO FOR MORE INFO.
KEYNOTES
11
12
D.032 D.033
##.###
REMOVE EXISTING LOUVER TO BE REPLACED REMOVE EXISTING SUSPENDED DRUM LIGHTS
13
D.033
D.033
D.033
14
DEMOLITION PLAN LEGEND CONTINUOUS LINE INDICATES EXISTING CONSTRUCTION TO REMAIN
15
16 D.033
D.033
DASHED LINE INDICATES CONDITION TO BE DEMOLISHED
17
D.033
ATRIUM
18
P-10
19 D.033 D.033
20
D.033
21
22 D.033 D.033
23
D.033
24 D.032
25
26
MECH STORAGE-2 P-05 ETR
P-04 ETR
ELEVATOR PENTHOUSE P-03 ETR
MECH 27
P-02 ETR
STORAGE -1 P-01 ETR
28
29
Murphy USA 30
Checker
31
32
Checked by:
33
Commision # 15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
34
35
36
Author
37
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
PENTHOUSE FLOOR DEMO REFLECTED CEILING PLAN
Drawn by:
CD 1
05 PENTHOUSE FLOOR DEMO REFLECTED CEILING PLAN 1/8" = 1'-0"
AD-125
SECONDARY 12/1/2015 4:13:15 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
U
X
GENERAL NOTES - FLOOR PLAN
CC 1.
34
15' - 0"
2. 3. 4. 5. OPEN TO BELOW 6. 7. 8.
37
9. 10.
11. 12.
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
SERVICE COURT 75' - 0"
N.I.C. - INDICATES AREA NOT IN CONTRACT
60' - 0"
KEYNOTES
##.###
43 03.005 05.002 05.037 10.004 12.012 26.002 32.001
K A
B
C
D
E
F
G
H
J
L
M
N
P
Q
R
S
T
U
V
EXISTING SOUTH CANOPY ROOF SEE LANDSCAPE FOR IMPROVEMENTS
RAISED CONCRETE SLAB - SEE STRUC. STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. CONCRETE FILLED STEEL PIPE BOLLARD CORNER GUARD - STAINLESS STEEL STAINLESS STEEL ENTRANCE FLOOR MAT AND FRAME IN-GRADE LIGHT FIXTURE - SEE ELECTRICAL THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB.
0.0
17' - 3 1/2"
DN
49
SERVICE DOCK 05.002
3' - 1"
001
30' - 0"
3
0.8 1
SOUTH CANOPY ROOF PLAN 1/8" = 1'-0"
2 CHILLERS
FIRE PUMP
3
4 U
X
05.037
CC
RECEIVING 001
34
STAIRS S1.0
FIBER TELECOM
SLOPE
32.001
K
011
010
STORAGE 010
9
A
12' - 5"
7' - 9"
9' - 2 1/2"
10 HOT WATER SYSTEMS
CORRIDOR ELEV. EQUIP.
8 03.005 003A
7' - 8"
004
011
19 BAYS @ 5'-0" = 95' - 0"
37
7
002
8' - 9"
A-503
30' - 0"
MECH EQUIPMENT ROOM
K2
4
1' - 11 1/2"
12.012
4 A-403
012
UP A-201
6
TOILET
S-01
115' - 4 1/2"
SLOPE
15' - 0"
1
5
10.004
A
008
12
75' - 0"
009
EX2
EX2
EX2
EX2
007B
007
43
ALIGN
MAIN ELECTRICAL
ALIGN
13 K2
27' - 6" VIF
14
Checker
26.002 26.002
26.002 26.002
15
003
MAIL ROOM
A
004
30' - 0"
003B
005
REPAIR VAPOR BARRIER AT SLAB AND DAMP/WATERPROOFING AT WALL TO ENSURE CONTINUITY OF MOISTURE RESISTANT SYSTEMS
17
7' - 2"
18 SEE STRUC.
19
EX2
EX2
EX2
20
49
3 A-403
Drawn by:
MM
30' - 0"
2 A-403
Commision #15054.00 200 Peach Street El Dorado, AR 71730
16
BUILDING OPERATIONS/ MECHANICS
EX2
Murphy USA
K
PRINT ROOM
Checked by:
11
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
BASEMENT PLAN
1 A-403 19 BAYS @ 5'-0" = 95' - 0"
2
SOUTH CANOPY FLOOR PLAN 1/8" = 1'-0"
1
00 BASEMENT 1/8" = 1'-0"
CD
A-100
12/1/2015 4:13:27 PM
SECONDARY 3
2
1
A-310
A-310
A-310
4 A-310
A
B
C
D
E
F
6 A-422
G
H
J
K
L
M
N
P
E.024
Q
R
S
T
U
V
W
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
05.002
4 A-422
5 A-422
E.027
X
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT MM
NN
PP
RR
SS
UU
07.007
A-201
VV
WW
1 A-106
05.002
07.013
SEE LANDSCAPE DRAWINGS
TT
6
0.0
A-201
CJ
A-201
145D
05.016
08.021
8
133A A
A
D1
CONFERENCE
G2
A
3' - 9"
111C
09.013 D1
WOMENS TOILET
9
105 A
A
10' - 0"
9' - 1 1/2"
11
OFFICE
129
131
G1
A
G1
G1
A
D1
G1 D1
5' - 10"
111B
07.007
G3
12
104
104
13
08.001 08.004 08.013 08.020
6'-3"
13
UP
06.008 06.009
07.013 D1
D1
05.011
128
MENS TOILET D1
01.001 01.003 05.002
05.016 05.017
OFFICE
130
D1
G2
138
D1
105
133C
133C
10' - 0"
OFFICE
22
132
E.003
142
10' - 0"
COPY
132
OFFICE
140
7 A-421
11' - 11"
11' - 11"
140
G1
A
8' - 3"
A-402
06.009
138
E
WIRING CLOSET
8
10 A
12' - 7 1/2"
A
CONFERENCE
S2.1
137B
39' - 1"
ELEC.
133
23' - 4"
18' - 7 1/2"
133B
133B
7 A-401
6' - 5"
7' - 1"
136
133A
A 144
108
A
143
A
STORAGE D
142
5' - 0 1/2"
ELEC.
D1
16' - 9 1/2"
KEYNOTES
7
A
16' - 3"
14' - 9 1/2"
141 106
143
G1
BREAKOUT
129
A
11' - 11"
OFFICE
STORAGE
130
6' - 5 1/2"
D1
N.I.C. - INDICATES AREA NOT IN CONTRACT
6
S-2
19' - 3"
131
E.002
D
A-411
09.003
A
11' - 5 1/2"
141
6 A-402
25' - 2 1/2"
11' - 5 1/2"
OFFICE
NE STAIR 2
6' - 9"
A
G3
G3
26' - 8 1/2" G2
UP
14
08.021 09.003
15
09.013
16
G3 44' - 2"
44' - 2"
36 BAYS @ 5'-0" = 180' - 0"
45' - 2 1/2"
200' - 4 1/2"
27' - 6"
A-411
OPEN WORKSTATION AREA OA-W1
OPEN WORKSTATION AREA
17
OA-E1
18
ATRIUM 2' - 6"
111 08.013
05.011
G3
08.013
19
01.001
20 G3
##.###
9
137A
08.020
134
134B
135B
G3
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
5
KITCHEN
134A
3' - 5 1/2"
135A
G3
A
12.
01.003 TYP
128
A
33' - 8"
11.
REF
6' - 8"
A
137
F
09.003
D
D
D
1' - 0 1/2" 6' - 9"
VESTIBULE 137E
146B
3
135
1' - 0 1/2" 145B
146A
6' - 8"
D
137
DINING ROOM
08.021
6' - 9"
STORAGE B
9. 10.
4
30' - 0"
STORAGE A
4 A-402
16' - 5 1/2"
A
146B
S1.1
F
146A
145A
1' - 0 1/2"
G4
6. 7. 8.
2
31' - 2 1/2"
32.001
137D
A
1/8" / 1'-0"
48' - 2 1/2"
44' - 5"
5' - 10"
UP
106
1
60' - 0"
145B
6' - 9"
MECH
0.8
05.002
1/8" / 1'-0"
TRAINING B
08.001
145A
30' - 0"
E-3
2. 3. 4. 5.
26.001
3' - 5 1/2"
TRAINING A
EJ
SERVICE ELEVATOR
05.017
07.013
4
5' - 0"
05.002 6' - 4"
1 A-502
14' - 7"
EXTERIOR VESTIBULE 137B
3.9
DN
A-201
1.
08.004
1/8" / 1'-0"
S-1
7
GENERAL NOTES - FLOOR PLAN
32.002 08.004
10
NW STAIR 1
1/8" / 1'-0"
A-411
05.002
32.005
3
EJ 07.007
01.003 TYP
5
A-201
05.016
05.002
2
25' - 2 1/2"
17' - 6"
05.016
A-201 A-503
157
137C
3' - 1"
8
ALIGN NEW SLAB TO EXISTING SLAB EDGE
1/8" / 1'-0"
157B
05.016
157D
ENCLOSED PATIO
157A
158
05.002
A-503
157C
145C
05.002
DN
COVERED PATIO 3/8" / 1'-0"
-2' - 6"
SEE LANDSCAPE DRAWINGS
8
3/8" / 1'-0"
1/8" / 1'-0"
32.002
5 A-502
20' - 5"
07.007
1/8" / 1'-0"
A-201
1" / 1'-0"
SEE LANDSCAPE DRAWINGS
17' - 3 1/2"
17' - 3 1/2"
47' - 1"
1
11.002 12.005 12.012 21.003 26.001 32.001 32.002 32.005 E.002 E.003 E.023 E.024 E.027
DASHED LINE INDICATES EDGE OF FLOOR OPENING ABOVE PAINT ALL WALLS AND RAILINGS WITHIN STAIRWELL STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. STEEL COLUMN WITH 2 HR. INTUMESCENT COATING - SEE STRUC. STAINLESS STEEL RAILING 2" X 3/4" BAR STOCK 3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH 1/2" EXTERIOR GRADE PLYWOOD PROVIDE 5/8" FIRE-RETARDANT PLYWOOD SHEATHING REINFORCEMENT FOR WALL MOUNTED DISPLAYS. SEE TA-DWGS FOR MORE INFO. 2" X 3" ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER SEE CIVIL 3.5" X 3.5" SQUARE ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER - SEE CIVIL OPERABLE FOLDING PARTITION SSG ALUMINUM CURTAIN WALL SYSTEM SOLAR CONTROL GLAZING SURFACE FILM ON EXISTING EXTERIOR WINDOWS ACCESSIBLE PUSH BUTTON AUTOMATIC DOOR OPENER AND CARD READER COMBINATION ACCESSIBLE PUSH BUTTON AUTOMATIC DOOR OPENER CUSTOM GRAPHIC / INFOGRAPHIC FULL HEIGHT (+/- 9') WALL COVERING. CONTRACTOR TO INSTALL, OWNER TO PROVIDE GRAPHIC DESIGN. PROVIDE LEVEL 5 GWB FINISH IN PREPARATION FOR ALL GRAPHIC WALL COVERING U.N.O. ADD (1) 5/8" GWB LAYER TO EXISTING PARTITION AND ACOUSTICALLY SEAL ALL GAPS AND PENTRATIONS. COPIER BY OWNER WORKSTATIONS - SEE INTERIORS STAINLESS STEEL ENTRANCE FLOOR MAT AND FRAME EMERGENCY KEY CABINET - COORDINATE LOCATION WITH FIRE MARSHALL LIGHT FIXTURE - SEE ELECTRICAL THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB. GRANITE SLAB ON 1/2" SETTING BED EXISTING SERVICE ELEVATOR TO REMAIN EXISTING GYPSUM BOARD COLUMN WRAP TO REMAIN SALVAGE STONE PANEL CLADDING. REINSTALL IN NEW LOCATION. EXISTING FLOOR DRAIN TO REMAIN SALVAGE EXISTING FLOOR DRAIN. REINSTALL IN SAME LOCATION IN NEW SLAB ON GRADE.
21
D1
152 D1
D1
F
D1 D1
D1
109
D1
ELEVATOR 1 E-1
D 14' - 1 1/2"
2' - 2 1/2"
13' - 5"
11 1/2"
1 1/2"
8' - 1"
124
123
D1
1 A-513
D1
7' - 6"
12' - 6"
122
13' - 9 1/2"
123
124
125
125
120
6' - 8"
17' - 3 1/2"
A G1
OFFICE
FILE/ WORK WIRING CLOSET
A
121
122 A
A
120
C2
C2
8' - 10 1/2"
ELEC.
57' - 4 1/2"
26
1 A-441
LOBBY 112 5
A-411
101
A-411
06.009
CONFERENCE
CONFERENCE
CONFERENCE
155
154
153
1 A-201
E
E
G2
06.009
08.021
VENDOR CONFERENCE
VENDOR CONFERENCE
116
117
E
S4.1
LOBBY TOILET ROOM
SE STAIR 4
114A
UP
G2
E
31
S-4
01.003
VENDOR CONFERENCE
34
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
35
FIRST FLOOR PLAN
TYP
118
15' - 0"
08.013
12.012 15' - 0"
15' - 0"
26.001
Drawn by:
37 21.003
1
01 FIRST FLOOR 1/8" = 1'-0"
Westlake Reed Leskosky
32
33 7' - 6 3/8"
Commision #15054.00 200 Peach Street El Dorado, AR 71730
36 08.013
15' - 0"
06.008
19' - 9 1/2"
112C 06.009
E
112
114
12
30
153
154
155
156 156
17' - 4"
CONFERENCE
06.009
10 116
E.023 4
G2
G2
159
G2 06.009
06.009
112D
5' - 7 1/2"
TYP
CUSTOMER EXPERIENCE
E.023 A-411
114A
10 A-512
08.020 G2
29
6 A-401
5' - 2 1/2"
CORRIDOR
JAN. 101
3
G2
28
CORRIDOR 119
G3 45' - 10"
Murphy USA
103
7
A
27
103
6
G3
UP
G2
113
MECH
A
11' - 3"
ALIGN
MURPHY USA STORE
118
7' - 8 1/2"
3 A-441
24
09.013
25
117A
G3
A
6 A-531
23
121
117B
ALIGN 159
S3.1
E-2
09.003
G3
6' - 3"
SW CORRIDOR
8' - 4 1/2"
Checker
OFFICE
G3
A
OA-S1
Checked by:
ELEVATOR 2
15' - 7"
110
26.001
OFFICE
22 10' - 0"
29' - 11 1/2"
5' - 2 1/2"
OPEN WORKSTATION AREA
WOMENS TOILET
MM
12' - 4 1/2"
8' - 10 1/2"
16' - 2 1/2"
D
01.003
10' - 0"
102 D
163
OFFICE G3
D1
A
10' - 0"
111A
1 A-512
160
149
110
G3
8' - 11"
109
160
STORAGE
10' - 6 1/2"
MENS TOILET
10' - 0"
G1
OFFICE
151
150
09.013
149
D1
OFFICE
COPY
D1
OFFICE
10' - 11"
G1
6' - 3"
147
41' - 3"
D1
14' - 9 1/2"
D1
3
5' - 4"
G1
115
OFFICE
15' - 5 1/2"
D1
112A
148
15' - 7"
2
A-301
112B
D1
OFFICE
G1
7' - 8 1/2"
4
G1
27' - 6"
15' - 10"
D1
5' - 6 1/2"
148
D1
152
6' - 7 1/2"
G1
14' - 9 1/2" 7 A-401
147
17' - 4"
10' - 6 1/2"
13 A-512 TYP.
G1
83' - 10 1/2"
151
D1
150
D1
SEE
2 / A-100
FOR CANOPY FLOOR PLAN
42 BAYS @ 5'-0" = 210' - 0"
CD
A-101
B
3
2
1
A-310
A-310
A-310
A-310
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
SLOPE
SLOPE
A
4
CC
DD
EE
FF
GG
HH
JJ
KK
SLOPE
12/1/2015 4:13:52 PM
SECONDARY
07.013
LL
MM
NN
PP
QQ 2 A-106
GUTTER HIGH POINT
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
2 A-502 07.007
GUTTER .5% SLOPE
6" GUTTER 1% SLOPE
05.019
0.0
GUTTER .5% SLOPE
SLOPED GUTTER
GUTTER .5% SLOPE
A-201 8
GUTTER HIGH POINT
GENERAL NOTES - FLOOR PLAN
1 3/4" / 1'-0"
GUTTER HIGH POINT
SLOPE
07.007
SLOPE
10' - 0"
GUTTER .5% SLOPE
7' - 3 1/2"
1.
2. 3. 4. 5.
08.006
07.001
08.006 07.007 GUTTER .5% SLOPE
16' - 0 1/2"
G1
D1
SR. DIRECTOR'S OFFICE
G1
240
OA-N2 232
1
11
16' - 0 1/2"
OPEN WORKSTATION AREA
D1
232
D1
0.8
GUTTER .5% SLOPE
117' - 11"
DIRECTOR'S OFFICE
10' - 2 1/2"
EQ.
SLOPE
1 3/4" / 1'-0"
GUTTER .5% SLOPE
3' - 1"
47' - 6"
07.013
10' - 2 1/2"
17' - 3 1/2"
GUTTER .5% SLOPE
A-501
4 A-502
2
3
EQ.
236
PRIVACY
237
238
D1
E.007 ALIGN
ALIGN
1' - 5 1/2"
241 D1
06.009
UP
D
243
D1
17' - 1"
G1
MANAGER'S OFFICE
8' - 8 1/2"
208
10' - 0"
ALIGN 08.011
8' - 11" 06.009 10' - 0"
D1
225
WIRING CLOSET
E-2
1 SIM. A-441
ALIGN D1
2XX
14.001
ADMINISTRATIVE ASSISTANT KITCHEN
COPY
217 D
17' - 1" 06.009
50' - 5"
17' - 1"
216 7' - 6"
DIRECTOR'S OFFICE D1
G1
248
D
FILES/ STORAGE
42' - 10 1/2"
17' - 2 1/2"
249
D
D1
OA-S2
D1
16' - 1 1/2"
10' - 5"
TEAMING
G1
10' - 4"
DIRECTOR'S OFFICE 219
D1
MECH
27
203 203
200
29
200
6' - 5"
D1
9 A-512
30
31 DN
SE STAIR 4 UP
S-4
251
34
16' - 2"
06.009
TEAMING
G1 D1
08.013
252
Drawn by:
37
1
02 SECOND FLOOR 1/8" = 1'-0"
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
SECOND FLOOR PLAN
36
27' - 8 1/2"
42 BAYS @ 5'-0" = 210' - 0"
Commision #15054.00 200 Peach Street El Dorado, AR 71730
32
35 OPEN TO BELOW
Murphy USA
JAN
6' - 5 1/2"
DIRECTOR'S OFFICE
219
08.013 16' - 0 1/2"
26
202
09.003
33
220 43' - 10"
MM
250
D1
251
06.009
D1
ELEC.
S4.2
G1
10' - 7 1/2"
D1
DIRECTOR'S OFFICE
10' - 5"
UP
250
OPEN WORKSTATION AREA
G1
221
25
ALIGN
10' - 2 1/2"
DN
D1
221
DIRECTOR'S OFFICE
10' - 7"
Checked by:
S3.2
ALIGN
24
09.013 17' - 3"
28
249
5' - 9"
62' - 6"
6' - 3"
Checker
D1
247
247
D1
D1
COATS 218
CONFERENCE
2
23
248
1 A-402
TEAMING
246
A
A-411
246
E-1
06.009
A
17' - 1"
12' - 0 1/2"
9' - 2 1/2"
TEAMING
5' - 5 1/2"
ELEVATOR 1
ELEVATOR 2
G2
245
CORRIDOR
223 6' - 9 1/2"
6' - 5 1/2"
245
22
9' - 0"
7 A-431
ALIGN
222
A
16
21
D1
SR. DIRECTOR'S OFFICE
6' - 7"
224
G1
REF
210
E.001
224
D
G1
3' - 9"
D1
09.003
WOMENS TOILET
A-412
253
D1
215 E.001
SR. MANAGER'S OFFICE
D1
2
3
14.001
210
A-301
11' - 0"
4
19
20
253
G1
10' - 1 1/2"
211
211
10' - 0"
A-432
17
D1
6' - 10"
10' - 6"
CONFERENCE
2 16' - 8"
MANAGER'S OFFICE
10' - 7 1/2" 5' - 3"
209
08.013
214 06.009
1
16
TEAMING
10' - 3"
OPEN TO BELOW
12.005 14.001 E.001 E.002 E.003 E.007
DASHED LINE INDICATES EDGE OF FLOOR OPENING ABOVE CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING PROVIDE 5/8" FIRE-RETARDANT PLYWOOD SHEATHING REINFORCEMENT FOR WALL MOUNTED DISPLAYS. SEE TA-DWGS FOR MORE INFO. STANDING SEAM ZINC ROOF OVER INSULATED STEEL DECK 2" X 3" ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER SEE CIVIL 3.5" X 3.5" SQUARE ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER - SEE CIVIL SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED GLASS GUARDRAIL W/S.S. STANDOFFS SOLAR CONTROL GLAZING SURFACE FILM ON EXISTING EXTERIOR WINDOWS CUSTOM GRAPHIC / INFOGRAPHIC FULL HEIGHT (+/- 9') WALL COVERING. CONTRACTOR TO INSTALL, OWNER TO PROVIDE GRAPHIC DESIGN. PROVIDE LEVEL 5 GWB FINISH IN PREPARATION FOR ALL GRAPHIC WALL COVERING U.N.O. ADD (1) 5/8" GWB LAYER TO EXISTING PARTITION AND ACOUSTICALLY SEAL ALL GAPS AND PENTRATIONS. WORKSTATIONS - SEE INTERIORS NEW STAINLESS STEEL ELEVATOR DOORS EXISTING PASSENGER ELEVATOR TO REMAIN EXISTING SERVICE ELEVATOR TO REMAIN EXISTING GYPSUM BOARD COLUMN WRAP TO REMAIN EXISTING RAISED FLOORING TO REMAIN
18
14' - 9 1/2"
10' - 0"
5' - 0"
01.001
G1
209
34' - 11 1/2"
OA-E2
DIRECTOR'S OFFICE
D1
MENS TOILET
OPEN WORKSTATION AREA
G1
15' - 8"
D1
09.013
15
09.003
225
D1
6' - 8"
D1
16
27' - 6"
227
G1
OA-W2
226
08.011 08.013 09.003
3' - 9" 10' - 0"
18' - 9"
A-412
227
8' - 11"
30' - 4 1/2" 14' - 10"
213
06.009
9' - 11"
200' - 4 1/2"
212
OPEN WORKSTATION AREA
D1
08.006
09.013
GUEST OFFICE
08.013
7 A-401
204
204
TEAMING TEAMING
226
12
14
A
D1
VP OFFICE
MENS TOILET
ALIGN
228
DN
06.009
D
G2
13 A-512 TYP.
07.001 07.007 07.013
01.001
229
D1
10
09.003
D1
ALIGN
A-411
06.009
11
D1
6 A-421
TYP.
9' - 1 1/2"
244
9
205
228 1
10' - 0"
14' - 9 1/2"
WIRING CLOSET
36 BAYS @ 5'-0" = 180' - 0"
E.003
WOMENS TOILET
205
13
10' - 1 1/2"
229
17' - 3 1/2"
01.001 05.019
D1
##.###
8
6' - 7"
243
244
A
KEYNOTES
7 A-401
D
D
206
ALIGN
N.I.C. - INDICATES AREA NOT IN CONTRACT
7
9' - 0"
43' - 11 1/2"
206
ELEC.
6
S-2
6' - 5"
E.007
85' - 0"
27' - 6"
E.002
A
D1
FILE/ STORAGE
MECH
06.009
NE STAIR 2
DATA CENTER
SERVICE ELEVATOR E-3
UP
242
233
CONFERENCE
242
233B UP
2YY
09.013
D1
DN
239
233A
MANAGER'S OFFICE
G1
TEAMING
E.007
11.
5
S2.2
A-402
H 230
CORRIDOR
21
241
4
8' - 1 1/2"
D
230
S1.2
DN
D1
D1
5' - 6"
S-1
SR. DIRECTOR'S OFFICE
FIRE DATA CENTER DATA CENTER SUPPRESSION UPS STORAGE VALVE 235
10.
12.
A 11' - 0 1/2"
10' - 7 1/2"
NW STAIR 1
234
G1
238
231
A
ALIGN 237
COPY
D1
UP
ALIGN
D 234
10' - 5"
231
SR. MANAGER'S OFFICE
10' - 5"
D1
GUEST OFFICE
7. 8. 9.
240 D1
3.9
6.
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
CD
A-102
SECONDARY 12/1/2015 4:14:04 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - FLOOR PLAN 1.
3' - 1"
0.8
332
G1
G1
334
338
D1
D1
D1
OPEN WORKSTATION AREA
DIRECTOR'S OFFICE 335
335
D1
SR. MANAGER'S OFFICE
G1
339
3' - 11 1/2"
D1
ALIGN
ALIGN
3' - 9"
ALIGN
3 A-402
MERCHANDISE DISPLAY AREA
G2 13
A-412
MECH 306
352
15' - 10"
CONFERENCE
341
REF
SR. MANAGER'S OFFICE
D1
D1
09.003
7 A-401
D1
ALIGN
E.003
TYP.
08.013
MENS TOILET
WIRING CLOSET
09.013
12
12.005 14.001 E.001 E.002 E.003
14
327
TEAMING HUDDLE
17' - 1"
336
D1 G1
326 326
D1
OPEN WORKSTATION AREA
06.009
6' - 3 5/8"
GUEST OFFICE
25' - 1 1/2"
6' - 8"
312
A-412
23' - 2 1/2"
14
10' - 5 1/2"
11
13
A
D1
09.003
DASHED LINE INDICATES EDGE OF FLOOR OPENING ABOVE PROVIDE 5/8" FIRE-RETARDANT PLYWOOD SHEATHING REINFORCEMENT FOR WALL MOUNTED DISPLAYS. SEE TA-DWGS FOR MORE INFO. SOLAR CONTROL GLAZING SURFACE FILM ON EXISTING EXTERIOR WINDOWS CUSTOM GRAPHIC / INFOGRAPHIC FULL HEIGHT (+/- 9') WALL COVERING. CONTRACTOR TO INSTALL, OWNER TO PROVIDE GRAPHIC DESIGN. PROVIDE LEVEL 5 GWB FINISH IN PREPARATION FOR ALL GRAPHIC WALL COVERING U.N.O. ADD (1) 5/8" GWB LAYER TO EXISTING PARTITION AND ACOUSTICALLY SEAL ALL GAPS AND PENTRATIONS. WORKSTATIONS - SEE INTERIORS NEW STAINLESS STEEL ELEVATOR DOORS EXISTING PASSENGER ELEVATOR TO REMAIN EXISTING SERVICE ELEVATOR TO REMAIN EXISTING GYPSUM BOARD COLUMN WRAP TO REMAIN
A
VP OFFICE 328 17' - 3 1/2"
10
304
304
327
G1
10' - 7 1/2"
ALIGN
328
9
305
308
14' - 10"
WOMENS TOILET
305
01.001 06.009
17' - 1"
6 A-421
##.###
09.003
7' - 11 1/2"
10' - 5"
7' - 11 1/2"
ELEC.
KEYNOTES
8
329
306
09.013
N.I.C. - INDICATES AREA NOT IN CONTRACT
7
341
A
6
S-2
ALIGN
G1 329
NE STAIR 2 DN
D1
COPY
06.009
85' - 0"
E-3
UP
OA-N3
355 15' - 7"
SERVICE ELEVATOR
12.
339
ALIGN
A
11.
5
3' - 11 1/2"
330 D1
ALIGN
G1
G1
4
338
D1
DIRECTOR'S OFFICE
10' - 7 1/2"
10' - 7 1/2"
S1.3
G1
9. 10.
DIRECTOR'S OFFICE
S2.3
G1
331
7. 8.
3
D1
330
E.002
D1
6.
2
337
MANAGER'S OFFICE G1
331
DN
G1
D1
SR. DIRECTOR'S OFFICE
334 10' - 5"
10' - 5"
DIRECTOR'S OFFICE D1
S-1
333 333
D1
UP
D1
337 332
NW STAIR 1
MANAGER'S OFFICE
15' - 7"
D1
D1
1
16' - 0 1/2"
10' - 5"
D1
59' - 2"
8' - 1 1/2"
DIRECTOR'S OFFICE
15' - 10"
10' - 2 1/2"
42' - 11" 10' - 2 1/2"
10' - 2 1/2"
16' - 0 1/2"
2. 3. 4. 5.
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
OA-E3
15
16
17
4
D1
06.009 D1
TEAMING
3
SR. DIRECTOR'S OFFICE 343
A
314
A
22 D1
D1
320
OPEN WORKSTATION AREA
8' - 2 1/2"
09.003
317
S4.3
9 A-512
30
31
SR. DIRECTOR'S OFFICE
G1 D1
D1
351
50' - 5"
SE STAIR 4 UP
S-4
32
G1 A-412
HUDDLE 318
Commision #15054.00 200 Peach Street El Dorado, AR 71730
350
35
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
36
THIRD FLOOR PLAN
34
16' - 0 1/2"
D1
VP OFFICE 351
Westlake Reed Leskosky
33
17 12' - 6"
10' - 3 1/2"
319
G1
E
G2
D1
SR. MANAGER'S OFFICE
29
300
DN
ENGINEERING CONFERENCE
17' - 1"
Murphy USA
JAN
26
350
50' - 5"
319
349
317
G1
16' - 0 1/2"
8' - 1 1/2"
344
COPY
06.009
OA-S3
320
303
2' - 10 1/2"
D1
27
303
A
G1 16' - 0 1/2"
10' - 7 1/2" 10' - 5"
A
321
D1
4' - 11"
A-402 D
MECH
17' - 1"
COATS 316
26
302
10' - 5"
8' - 8"
D1
MANAGER'S OFFICE
MANAGER'S OFFICE
MANAGER'S OFFICE 348
321 D1
ELEC.
3' - 11 1/2"
G1
D1
S3.3
Checker Checked by:
UP
315
15' - 5 1/2"
322 17' - 1"
G1
25
D1
COFFEE
12' - 3"
SR. DIRECTOR' S OFFICE
17' - 3 1/2" 346
28
348
ALIGN
DN
ADMINISTRATIVE ASSISTANT 347
3' - 11 1/2"
09.003
2 A-402
322
D1
24 09.013
G1
14.001
D
323
62' - 6"
310
ALIGN
TEAMING
3' - 11"
310
E-2
E-1
346
01.001
1 SIM. A-441
10' - 5"
7' - 9" 10' - 5 1/2"
5' - 4 1/2"
06.009
WOMENS TOILET
ELEVATOR 2
ELEVATOR 1
14.001
D
344
A
G1
A
WIRING CLOSET
324 D1
ALIGN
309
E.001
ALIGN
309
E.001
ALIGN
MENS TOILET
16
23
SR. VP OFFICE
A
5' - 4 1/2"
G2
17' - 3 1/2"
A-412
DIRECTOR'S OFFICE D1 324
09.013
10' - 4"
06.009
ALIGN
14' - 9 1/2"
325
D1
345
D1
21
G1
17' - 1"
REF
7 A-401
A-412
17' - 0 1/2"
SR. DIRECTOR'S OFFICE
345
343 12
G1
D1
2
A-301
325
CONFERENCE
20 D1
311 311
9' - 10 1/2"
340
9' - 7"
G1
342
D1
1
19
353
SR. DIRECTOR'S OFFICE
ATRIUM A-432
08.013
10' - 0"
D1
19' - 8"
353 342
ALIGN
2
MANAGER OFFICE
D1
G1 D1
313
CONFERENCE
D
TEAMING
OPEN TO BELOW
OA-W3
13 A-512 TYP.
340
15' - 0"
D
18
9' - 9 1/2"
08.013
FILES/ STORAGE
06.009
OPEN WORKSTATION AREA
4' - 3 1/2"
01.001
8' - 11" 30' - 4 1/2"
36 BAYS @ 5'-0" = 180' - 0"
183' - 1"
D
08.013
D1
MM
37
Drawn by:
CD 1
03 THIRD FLOOR 1/8" = 1'-0"
42 BAYS @ 5'-0" = 210' - 0"
A-103
SECONDARY 12/1/2015 4:14:15 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
GENERAL NOTES - FLOOR PLAN 1.
3' - 1"
0.8 16' - 0 1/2"
16' - 4"
D1
56' - 7"
4' - 9"
28' - 11 1/2"
21' - 1 1/2"
35' - 5 1/2"
G1
A
VP OFFICE
D1
D1
434 G1
2
15' - 2 1/2"
OFFICE 436
WIRING CLOSET
OFFICE
418
472
15' - 10"
S2.4 438
439
440
441
OFFICE
442
440
6' - 8"
D1
D1
A-402
9' - 1 1/2"
10' - 2 1/2"
OFFICE
OFFICE
439
438
8' - 11 1/2"
5 A-402
6 A-421
05.001
10 08.002 08.013
11
08.002
MENS TOILET
G3
G2
A
11' - 5 1/2"
18' - 4"
D1
12
13 17' - 3 1/2"
6' - 8" 09.013
CONFERENCE
4
444
OFFICE
D1
VP OFFICE 443
15
D1
415
G1
A
D1
OFFICE
16
443
445
11.002 12.005 12.010 12.011
445
15' - 10"
09.013
14
A-412
444
09.003
09.003
404
404
6' - 5 1/2"
05.001 06.009
J10 A-615
A
9
KEYNOTES
405
D1
06.009
A
WOMENS TOILET
405
09.003
24
A-412
31' - 5 1/2"
8
D1
06.009
A
A
G1
10' - 2 1/2"
7 A-401
G3
16' - 9"
7' - 5 1/2"
E.003
D1
N.I.C. - INDICATES AREA NOT IN CONTRACT
7
A
441 E
G1
10' - 2 1/2"
COPY
COFFEE/ KITCHEN
A-412
10' - 2 1/2"
D1
CONFERENCE A
10
G1
10' - 5"
1
471
D
27' - 6"
421
16' - 1"
10' - 3"
A
D1
472
418
421
06.009
G1
11' - 3"
CONFERENCE
11' - 0 1/2"
ALIGN
G2
G1
ALIGN
6' - 6" 06.009
422
6' - 3 1/2"
08.002 A
420
17' - 3"
11' - 8 1/2"
431
G3
408
21' - 2"
TEAMING
G3
481
6' - 5 1/2"
ELEC.
G2
6
DN
482
A-412
A
A
S-2
435
G3
OUTSIDE AUDITORS
NE STAIR 2
6' - 8"
3
11.002
16' - 4"
G3
A
406
REF
45' - 0"
A
A-412 7
8' - 11"
E-3
G3 G3
G3
437
428 6
11. 12.
437
431
17' - 1"
429
14' - 7"
E.002
406
10' - 9 1/2"
426A
FILE/ WORK
SERVICE ELEVATOR MECH
G1
14' - 10 1/2"
6' - 5 1/2"
A
429
6' - 5 1/2"
G3
428
OFFICE
14' - 9"
CORRIDOR
ALIGN
427
6' - 3 1/2"
S1.4
426A
D1
FILES/ WORK
G1
D
430
442
G3
EXPANSION 12' - 6"
G3
433
14' - 7 1/2"
423 A 426
DN
A
A
435 D1
427
CHECK ROOM
5
CONTROLLER
G1
433
3' - 4 1/8"
10' - 7 1/2"
S-1
AUDIT
426
423
OFFICE
14' - 7"
TREASURY
6' - 3 1/2"
2
424
26' - 6"
D1 A
6' - 3"
A
4
A-412 10' - 0"
424
7. 8.
10.
436
434
31' - 3"
10' - 5"
D1
6.
9.
A
D1
OFFICE
3
G1
449B
425 D1 425
NW STAIR 1
1
16' - 0 1/2"
OFFICE 15' - 2 1/2"
10' - 2 1/2"
16' - 0 1/2"
2. 3. 4. 5.
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
14.001 22.002 E.001 E.002 E.003 E.014
##.###
STEEL BEAM W/2 HR. SPRAY-ON FIREPROOFING - SEE STRUC. PROVIDE 5/8" FIRE-RETARDANT PLYWOOD SHEATHING REINFORCEMENT FOR WALL MOUNTED DISPLAYS. SEE TA-DWGS FOR MORE INFO. ACCORDION DOOR SOLAR CONTROL GLAZING SURFACE FILM ON EXISTING EXTERIOR WINDOWS CUSTOM GRAPHIC / INFOGRAPHIC FULL HEIGHT (+/- 9') WALL COVERING. CONTRACTOR TO INSTALL, OWNER TO PROVIDE GRAPHIC DESIGN. PROVIDE LEVEL 5 GWB FINISH IN PREPARATION FOR ALL GRAPHIC WALL COVERING U.N.O. ADD (1) 5/8" GWB LAYER TO EXISTING PARTITION AND ACOUSTICALLY SEAL ALL GAPS AND PENTRATIONS. COPIER BY OWNER WORKSTATIONS - SEE INTERIORS REPLACE EXISTING MARBLE COUNTERTOPS WITH NEW MARBLE COUNTERTOPS RECLAD EXISTING MARBLE COUNTERTOP WITH NEW QUARTZ COUNTERTOP NEW STAINLESS STEEL ELEVATOR DOORS SINK, SEE PLUMBING EXISTING PASSENGER ELEVATOR TO REMAIN EXISTING SERVICE ELEVATOR TO REMAIN EXISTING GYPSUM BOARD COLUMN WRAP TO REMAIN SALVAGE CUSTOM RECESSED DOOR AND FRAME ASSEMBLY .DISMANTLE AND REASSEMBLE IN NEW LOCATION.
D1
17
420
416 D1
D1
D1
A
419
G2 409
08.002 484
6' - 5 1/2"
9' - 1 1/2"
A
10' - 10" D1
7' - 8 1/2"
D1
E-2
14.001
EXECUTIVE VISITING
14' - 7"
469
SIM. 24 A-401
ELEC.
STORAGE
COPY
464
455
A
LEGAL
467
12.010
16' - 0"
12.010
4' - 6"
462
12' - 9"
5' - 9 1/2"
18' - 10"
9
8' - 11 1/2" 458A
459
460
461
A
G4
G4
A
17' - 0 1/2"
15' - 2 1/2"
OFFICE
A
461
OFFICE
G1
466
A
OFFICE
CONFERENCE
459
458
460
466
14' - 9 1/2"
EXECUTIVE BOARDROOM 22.002 12.010
12.010
E.014 J8 A-615
OFFICE
30
31 DN
32
453
35
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
36
FOURTH FLOOR PLAN
34
457 08.013
5' - 2 1/2"
20' - 0"
21' - 0 1/2"
28' - 2"
458B
Westlake Reed Leskosky
33
WET BAR 457
Commision #15054.00 200 Peach Street El Dorado, AR 71730
SE STAIR 4 S-4
456
G4
A
23 A-401
A-412
453A
A
9 A-512 S4.4
452
EXECUTIVE
468B
A
A
MEETING TOILET
8
A-412
451
456
11
7' - 3 1/2"
29
A/V ROOM
CONFERENCE G4
Murphy USA
400
12.011
G1
468
D1
28
JAN
12.011
A
06.009
27
403
462
463
13' - 11 1/2"
CONFERENCE
403
UP
463
13' - 6 1/2" 16' - 0 1/2"
1' - 10"
S-6
450
451
3' - 7 1/2"
467
ALIGN 18' - 2"
G2
S3.4 DN
MECH
KITCHEN
12.010
465 6' - 5 1/2"
6' - 5 1/2"
468D
15 ALIGN
PENTHOUSE STAIR
A
A
26
402
A-412 G3
24 09.013
25
465
G1
A
454
14.001
A
G1
23 483
ALIGN
469
14' - 7"
470
470
410
410
21' - 0 1/2"
A
WOMENS TOILET
OFFICE
1 A-441
TOILET
1' - 11"
OFFICE
G3
448 A
08.002
ELEVATOR 2
E-1
10' - 7 1/2"
D1
22
WIRING CLOSET
E.001
ELEVATOR 1
ALIGN G3
10' - 5"
E.001
6' - 5 1/2"
409
2
A-432
13' - 9 1/2"
413
A-301
12.005
10' - 5 1/2"
CONFERENCE
5
4
1
06.009 A-412
A-432
411
D1
09.013
21
3
413
MENS TOILET
A-432
449A
A
419
D1
2
448
414
20
453B
G1
G1
447 A
1
4
411
10' - 3"
INSURANCE
CONFERENCE
OFFICE
19
449
1
A-431
OFFICE
ATRIUM
A
08.013
15' - 2 1/2"
D1
D1
450
23
9' - 11 1/2"
A-402
G1
OFFICE OF THE CEO
447
10' - 10"
417
414
Checker
18
G1
446
33' - 9 1/2"
3' - 9 1/2"
COPY 10' - 3"
51' - 5 1/2"
49' - 2 1/2"
415
D
Checked by:
OFFICE
OPEN TO BELOW
08.013
7 A-401
D1
9' - 5"
OFFICE
10' - 5"
HSSE
10' - 3"
36 BAYS @ 5'-0" = 180' - 0"
446 A
MM
37 A
Drawn by:
13 A-512
CD
TYP.
42 BAYS @ 5'-0" = 210' - 0"
1
04 FOURTH FLOOR 1/8" = 1'-0"
A-104
12/1/2015 4:14:24 PM
SECONDARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
GENERAL NOTES - FLOOR PLAN 1.
3' - 1"
0.8 1
2
3
2. 3. 4. 5.
6. 7. 8. 9. 10.
3.9
4
5
11. 12.
6
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
N.I.C. - INDICATES AREA NOT IN CONTRACT
7
8 ROOF
9
10
11
KEYNOTES 12
13
05.014 08.011 08.013 11.007 D.043
14
##.###
LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD GLASS GUARDRAIL W/S.S. STANDOFFS SOLAR CONTROL GLAZING SURFACE FILM ON EXISTING EXTERIOR WINDOWS FALL PROTECTION ROOF ANCHOR REMOVE EXISTING LOUVER FOR NEW LOUVER REPLACEMENT - SEE ROOF PLAN AND MECH.
08.011
15 08.011
08.011
16
08.013
ROOF
OPEN TO BELOW 4' - 0"
1.
18
2.
19 08.013
4' - 0"
3.
ROOFING TO BE PATCHED AND REPAIRED PER MANUFACTURER WARRANTY REQUIREMENTS TO ACCOMMODATE M.E.P. PENETRATIONS INCLUDING BUT NOT LIMITED TO EXHAUST FAN CURBS, PLUMBING VENTS, POWER CONDUITS, ETC. ALL BLOCKING, FLASHING AND SEALANTS TO BE REPLACED AT NEW LOUVER LOCATIONS. MATCH EXISTING FLASHING MATERIAL AND CONFIGURATION WITH FULL PERIMETER BACKER ROD AND SEALANT AT BOTH INTERIOR AND EXTERIOR SIDES. LOUVER COLOR PREFINISHED TO MATCH EXISTING. EXISTING EXTERIOR DOOR TO BE REFINISHED. REMOVE ALL OXIDATION, CLEAN, PRIME AND PAINT TO LIKE NEW CONDITION, COLOR TO MATCH EXISTING.
20 4' - 5"
STEEL FALL PROTECTION ANCHOR TO BE WELDED TO EXISTING STEEL COLUMN AT 4'-6" AFF - SEE STRUC.
11.007 TYP.
1
21
2 A-432
4
A-301
2
22
3 ANCHORS TO ALIGN AND CONNECT W/ STEEL BEAMS BELOW SLAB SEE STRUC.
3 A-432
D.043
17
ROOF
4' - 5"
36 BAYS @ 5'-0" = 180' - 0"
183' - 1"
PENTHOUSE/ROOF PLAN NOTES:
23 05.014
08.011
D.043
08.011 4
24 D.043
A-441
25
DN F
26
STORAGE-2
ELEVATOR PENTHOUSE
MECH P-04
P-05
P-03
MECH P-02
STORAGE -1
27
P-01
DN
28
Murphy USA 29
Checker
30
31
Checked by:
A-412
32
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
33
35
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
36
PENTHOUSE FLOOR PLAN
ROOF
34
MM
37
Drawn by:
CD 42 BAYS @ 5'-0" = 210' - 0"
1
05 PENTHOUSE FLOOR 1/8" = 1'-0"
A-105
SECONDARY 12/1/2015 4:14:46 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
GENERAL NOTES - FLOOR PLAN 1.
2. 3. 4. 5.
6. 7. 8. 9. 10.
11. 12.
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY DESIGNER OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE A-600 FOR PARTITION TYPES SEE A-610 FOR DOOR SCHEDULE ALL DIMENSIONS ARE FINISH TO FINISH U.O.N. WHEN PATCHING TO MATCH EXISTING WALLS, THE CONTRACTOR SHALL REPAIR WALLS USING SUCH METHODS AND SUCH MATERIALS TO MAINTAIN THE ORIGINAL FIRE AND SOUNDS RATINGS. ALL ITEMS TO REMAIN THAT ARE DAMAGED BY DEMOLITION OR NEW CONSTRUCTION SHALL BE REFINISHED AND REPAIRED TO MATCH ORIGINAL CONDITION. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT. PROVIDE CONT. 20 GA. SHEET METAL BLOCKING TO ANCHOR WALL MOUNTED ITEMS INCLUDING SHELVING AND CASEWORK U.O.N. ALL FLOOR SLAB PENETRATIONS SHALL BE SEALED WITH U.L. FIRESTOPPING AND/OR CONCRETE TO MAINTAIN FIRE RATING. CONTRACTOR SHALL ENSURE THAT EXISTING GAS, STORMWATER, ELECTRICAL, PHONE, SANITARY, POTABLE AND NON-POTABLE WATER AND ALL OTHER UTILITIES ARE MAINTAINED IN SERVICE AT ALL TIMES DURING CONSTRUCTION UNLESS OTHERWISE INSTRUCTED BY OWNER. REPAIR AND REPLACE ANY EXPOSED STRUCTURE OR CONSTRUCTION THAT WAS PREVIOUSLY COVERED WITH FIREPROOFING OR INSTALLED WITH THERMAL INSULATION. SEE SHEET A-106 FOR ALTERNATE #2. REFER TO SPEC SECTION 012300 FOR DESCRIPTION.
N.I.C. - INDICATES AREA NOT IN CONTRACT
KEYNOTES 05.002 05.017 05.019 08.006 32.001 E.019
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
##.###
STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. 3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. EXISTING CONCRETE RETAINING WALL TO REMAIN.
RR
47' - 6"
0.0
10' - 0"
SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED
7' - 3 1/2"
CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING
3' - 1"
0.8
1
ENLARGED ROOF PLAN - ENCLOSURE ALT #2
2 CC
DD
1/4" = 1'-0"
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
75' - 0"
0.0
Murphy USA
3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH
1
Commision #15054.00 200 Peach Street El Dorado, AR 71730
THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB.
17' - 3 1/2"
20' - 4 1/2"
Checked by:
Checker
A-422
Westlake Reed Leskosky
EXISTING CONCRETE RETAINING WALL TO REMAIN.
STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. TYP. ALL COLUMNS.
EXTERIOR THERMAL GLASS AND ALUMINUM ENTRANCE WITH EXIT ONLY HARDWARE ACTIVATED BY SMOKE EVACUATION SYSTEM
0.8
3' - 1"
T
Drawn by:
MM
1
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
ENCLOSED PATIO ALTERNATE
CD 1
ENLARGED PLAN - ENCLOSURE ALT #2 1/4" = 1'-0"
A-106
PRIMARY 12/1/2015 4:14:57 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
GENERAL NOTES REFLECTED CEILING PLAN 1. REFLECTED CEILING PLANS CONSTITUTE A GRAPHIC REPRESENTATION OF CEILING-MOUNTED ELEMENTS FOR THE PURPOSE OF COORDINATION. REFER TO THE APPROPRIATE DISCIPLINE FOR INFORMATION REGARDING EACH OF THESE ELEMENTS. 2. ALL CEILING HEIGHTS AT 9'-0" AFF, U.N.O. CEILING HEIGHT S ARE FROM FINISH FLOOR TO FINISH CEILING. REFER TO REFLECTED CEILING PLANS FOR HEIGHTS. 3. CEILING GRIDS OR TILES SHALL BE CENTERED IN SPACE UNLESS NOTED OR DIMENSIONED OTHERWISE. ALIGN CEILING GRIDS AND FIXTURES AS NOTED OR DIMENSIONED. 4. WHERE FIXTURE OR DEVICES ARE SHOWN IN THE CEILING PANEL, THEY SHALL BE CENTERED IN THE PANEL UNLESS OTHERWISE INDICATED. 5. SUSPEND ACOUSTICAL CEILING TYPICALLY 1" ABOVE ADJACENT GYPSUM WALL BOARD SOFFITS AND BULKHEADS UNLESS NOTED OTHERWISE. 6. ALL SOFFITS AND BULKHEADS SHALL BE BRACED LATERALLY TO RESIST HORIZONTAL MOVEMENT. 7. IF A FIXTURE OR OTHER CEILING DEVICE IS NOT SHOWN OR DIMENSIONED - CONFIRM LOCATION WITH ARCHITECT. 8. IN THE EVENT OF CONFLICTS BETWEEN REFLECTED CEILING PLANS AND CORRESPONDING DISCIPLINES, BRING THE CONFLICT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.
REFLECTED CEILING PLAN LEGEND
OPEN TO ABOVE
SUSPENDED 2'x4' LAY-IN ACOUSTICAL CEILING TILE SUSPENDED 2'x4', 4"X4' LAY-IN TECHNICAL CEILING PANEL SUSPENDED 2'x2' LAY-IN ACOUSTICAL CEILING TILE GYPSUM BOARD CEILING, PAINTED
EXP
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
EXPOSED TO STRUCTURE, PAINTED
U SOUND ABSORBING ACOUSTICAL PLASTER ASSEMBLY RECESSED ADJUSTABLE FIXTURE
0.0
LAY-IN LIGHT FIXTURE
17' - 3 1/2"
4" CONTINUOUS LINEAR LIGHT FIXTURE CJ
CONTROL JOINT SPEAKER - SEE A/V
SERVICE DOCK
SPRINKLER HEAD
N.I.C. - INDICATES AREA NOT IN CONTRACT
3' - 1"
0.8 1
KEYNOTES 2
07.002
##.###
EXTERIOR GRADE GYPSUM BOARD SOFFIT PANEL PAINTED.
3
4
TOILET RECEIVING
012
001
MECH EQUIPMENT ROOM
5
002 EXP
EXP EXP
6 EXP
7 S
T
U
V
W
X
AA
BB
CC
DD
EE
FF 011
8 EXP
9 19 BAYS @ 5'-0" = 95' - 0"
37
FIBER TELECOM
115' - 4 1/2"
R
10
11
CORRIDOR ELEV. EQUIP. MAIN ELECTRICAL
EXP
008
12
009
007 EXP
EXP
13
Murphy USA
EXP
MAIL ROOM
Checker
43
14
004 9' - 0" AFF
15
PRINT ROOM 003
Checked by:
9' - 0" AFF
BUILDING OPERATIONS/ MECHANICS
16
Westlake Reed Leskosky
17
005
07.002
18 9' - 0" AFF
19 18 BAYS @ 5'-0" = 90' - 0"
20
MM
49
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
BASEMENT REFLECTED CEILING PLAN
CD 2
SOUTH CANOPY RCP 1/8" = 1'-0"
1
00 BASEMENT REFLECTED CEILING PLAN 1/8" = 1'-0"
A-120
12/1/2015 4:15:30 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
0.0
COVERED PATIO
ENCLOSED PATIO
158
157
SLOPE
17' - 3 1/2"
8' - 10" AFF
08.006
GENERAL NOTES REFLECTED CEILING PLAN
3' - 1"
0.8 9' - 0" AFF
12.001
12.001
12.001
10
12.001
12.002
9
12.002
A-562
27.005
TRAINING A
27.005
TRAINING B
8
145A
3.9
145B
A-561
1
2. ALL CEILING HEIGHTS AT 9'-0" AFF, U.N.O. CEILING HEIGHT S ARE FROM FINISH FLOOR TO FINISH CEILING. REFER TO REFLECTED CEILING PLANS FOR HEIGHTS.
2
3. CEILING GRIDS OR TILES SHALL BE CENTERED IN SPACE UNLESS NOTED OR DIMENSIONED OTHERWISE. ALIGN CEILING GRIDS AND FIXTURES AS NOTED OR DIMENSIONED.
3
4. WHERE FIXTURE OR DEVICES ARE SHOWN IN THE CEILING PANEL, THEY SHALL BE CENTERED IN THE PANEL UNLESS OTHERWISE INDICATED.
12.002
A-561
DINING ROOM 4
135
9' - 0" AFF
9' - 0" AFF
5. SUSPEND ACOUSTICAL CEILING TYPICALLY 1" ABOVE ADJACENT GYPSUM WALL BOARD SOFFITS AND BULKHEADS UNLESS NOTED OTHERWISE.
9' - 0" AFF
5 27.006
27.006 13
STORAGE A
STORAGE B
146A EXP
134
6
S-2
137
146B EXP
NE STAIR 2
A-562
VESTIBULE
6. ALL SOFFITS AND BULKHEADS SHALL BE BRACED LATERALLY TO RESIST HORIZONTAL MOVEMENT. 7. IF A FIXTURE OR OTHER CEILING DEVICE IS NOT SHOWN OR DIMENSIONED - CONFIRM LOCATION WITH ARCHITECT.
KITCHEN
NW STAIR 1 S-1
1. REFLECTED CEILING PLANS CONSTITUTE A GRAPHIC REPRESENTATION OF CEILING-MOUNTED ELEMENTS FOR THE PURPOSE OF COORDINATION. REFER TO THE APPROPRIATE DISCIPLINE FOR INFORMATION REGARDING EACH OF THESE ELEMENTS.
9' - 0" AFF
9' - 0" AFF
8. IN THE EVENT OF CONFLICTS BETWEEN REFLECTED CEILING PLANS AND CORRESPONDING DISCIPLINES, BRING THE CONFLICT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.
7
REFLECTED CEILING PLAN LEGEND CJ
CJ
14
CJ
A-562
OFFICE
OFFICE
141
143
MECH
STORAGE
STORAGE
ELEC.
133A
133B
133C
EXP
EXP
EXP
OFFICE
130
129
128
CONFERENCE OFFICE WIRING CLOSET
9' - 0" AFF
EXP
11
A-561
EXP
12
MENS TOILET
RECESSED ADJUSTABLE FIXTURE
104
9' - 0" AFF
14
LAY-IN LIGHT FIXTURE
13
A-562
4" CONTINUOUS LINEAR LIGHT FIXTURE
14
12.001
13
OPEN WORKSTATION AREA
A-562
OA-W1
CJ
CONTROL JOINT SPEAKER - SEE A/V
13 A-562
15
OPEN WORKSTATION AREA
9' - 0" AFF 200' - 4 1/2"
EXPOSED TO STRUCTURE, PAINTED SOUND ABSORBING ACOUSTICAL PLASTER ASSEMBLY
A-562
9' - 0" AFF
108
GYPSUM BOARD CEILING, PAINTED
14
131
140 EXP
ELEC.
10
7
COPY
132
142
SUSPENDED 2'x2' LAY-IN ACOUSTICAL CEILING TILE
14 A-562
OFFICE
SUSPENDED 2'x4', 4"X4' LAY-IN TECHNICAL CEILING PANEL
105 9' - 0" AFF
138
OFFICE
SUSPENDED 2'x4' LAY-IN ACOUSTICAL CEILING TILE
9
WOMENS TOILET
CONFERENCE
106
8
SPRINKLER HEAD
13 A-562
16
N.I.C. - INDICATES AREA NOT IN CONTRACT
12.001
OA-E1
13
9' - 0" AFF
A-562
17
KEYNOTES
##.###
12 36 BAYS @ 5'-0" = 180' - 0"
9' - 0" AFF
9' - 0" AFF
4
A-562
4
08.006
18
A-562
A-562
9' - 0" AFF EXP
EXP
EXP
9' - 0" AFF
19
EXP
OPEN TO ABOVE
12.001 12.002 27.005 27.006 E.006
SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED MANUAL ROLLER SHADE MOTORIZED ROLLER SHADE. PROJECTOR - SEE AV PROJECTOR SCREEN - SEE AV EXISTING CEILING TO REMAIN
12.001
20
9' - 0" AFF 9' - 0" AFF
10
12.001
ATRIUM
A-562
21
111
22
OFFICE 148
OFFICE
OFFICE
OFFICE
151
152
COPY
OFFICE 120
150
147
OFFICE
OFFICE
OFFICE
125
124
123
23
FILE/ WORK WIRING CLOSET 121
122
9' - 0" AFF 14
12.001
EXP
9' - 0" AFF
24
9' - 0" AFF
STORAGE
A-562
160
OFFICE 149
ELEVATOR 1
ELEVATOR 2
E-1
E-2
25
ELEC.
MENS TOILET 109 9' - 0" AFF
102
CORRIDOR
14
26
E.006 E.006
119
A-562 EXP
MURPHY USA STORE
7 A-561
14
LOBBY
A-562
112
27 9' - 0" AFF
MECH
113
103
28
CJ
13
OPEN WORKSTATION AREA
A-562
OA-S1
WOMENS TOILET 110
Checked by:
Checker
14
4
JAN.
10' - 0" AFF
29
101 6 A-562
CUSTOMER EXPERIENCE
A-562
A-562
4
CJ
A-561
9' - 0" AFF
U.L. C-AJ-7027 SEAL AT FLOOR PENETRATION FOR DUCT SHAFT
30
31
Commision #15054.00 200 Peach Street El Dorado, AR 71730
32
Westlake Reed Leskosky
114
LOBBY TOILET ROOM
CJ
SW STAIR 3
114A
SE STAIR 4 S-4
S-3
CORRIDOR
33
159
34
CONFERENCE
CONFERENCE
CONFERENCE
CONFERENCE
156
155
154
153
OPEN TO ABOVE
VENDOR CONFERENCE
VENDOR CONFERENCE
116
117
VENDOR CONFERENCE
35
118
MM
36
Drawn by:
Murphy USA
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FIRST FLOOR REFLECTED CEILING PLAN
37 12.002
12.002
12.002
12.002 SEE
2 / A-120
12.002 FOR CANOPY RCP 42 BAYS @ 5'-0" = 210' - 0"
12.002
12.002
12.002
CD
A-121
12/1/2015 4:15:50 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
GENERAL NOTES REFLECTED CEILING PLAN
3' - 1"
0.8
12.001
12.001
DIRECTOR'S OFFICE
SR. DIRECTOR'S OFFICE
12.001
12.001
OPEN WORKSTATION AREA
232 9' - 0" AFF
240 9' - 0" AFF
OA-N2
231
SR. DIRECTOR'S OFFICE
NW STAIR 1
234
S-1
235
4
230
9' - 0" AFF
A-562 9' - 0" AFF
EXP
9' - 0" AFF
FIRE DATA CENTER DATA CENTER SUPPRESSION PRIVACY 238 VALVE UPS STORAGE
COPY
236
TEAMING
237
239
EXP
NE STAIR 2
242
S-2
9' - 0" AFF
EXP
7
6. ALL SOFFITS AND BULKHEADS SHALL BE BRACED LATERALLY TO RESIST HORIZONTAL MOVEMENT.
8. IN THE EVENT OF CONFLICTS BETWEEN REFLECTED CEILING PLANS AND CORRESPONDING DISCIPLINES, BRING THE CONFLICT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.
REFLECTED CEILING PLAN LEGEND
A-562
8
SUSPENDED 2'x4' LAY-IN ACOUSTICAL CEILING TILE
A-562
233
FILE/ STORAGE
SUSPENDED 2'x4', 4"X4' LAY-IN TECHNICAL CEILING PANEL
243
ETR
13
SUSPENDED 2'x2' LAY-IN ACOUSTICAL CEILING TILE
205 14
MANAGER'S OFFICE
MECH
9
WOMENS TOILET
9' - 0" AFF
10
A-562
244
EXP
A-562
11
7
9' - 0" AFF
14
A-561
GYPSUM BOARD CEILING, PAINTED
EXP
12
204
RECESSED ADJUSTABLE FIXTURE
9' - 0" AFF
208 9' - 0" AFF CJ
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
14 13
12.001
WIRING CLOSET
LAY-IN LIGHT FIXTURE
13
A-562
4" CONTINUOUS LINEAR LIGHT FIXTURE
A-562
14
228
229
CJ
9' - 0" AFF
13
5 A-421
227
SPRINKLER HEAD
15
213
GUEST OFFICE
CONTROL JOINT SPEAKER - SEE A/V
TEAMING
9' - 0" AFF
EXPOSED TO STRUCTURE, PAINTED SOUND ABSORBING ACOUSTICAL PLASTER ASSEMBLY
MENS TOILET
A-562
13
CONFERENCE
5. SUSPEND ACOUSTICAL CEILING TYPICALLY 1" ABOVE ADJACENT GYPSUM WALL BOARD SOFFITS AND BULKHEADS UNLESS NOTED OTHERWISE.
14
13
DATA CENTER
9' - 0" AFF
4. WHERE FIXTURE OR DEVICES ARE SHOWN IN THE CEILING PANEL, THEY SHALL BE CENTERED IN THE PANEL UNLESS OTHERWISE INDICATED.
6
CJ
A-562
3
A-562
EXP
ELEC.
3. CEILING GRIDS OR TILES SHALL BE CENTERED IN SPACE UNLESS NOTED OR DIMENSIONED OTHERWISE. ALIGN CEILING GRIDS AND FIXTURES AS NOTED OR DIMENSIONED.
7. IF A FIXTURE OR OTHER CEILING DEVICE IS NOT SHOWN OR DIMENSIONED - CONFIRM LOCATION WITH ARCHITECT.
CJ
206
2
5
MANAGER'S OFFICE 4
9' - 0" AFF
E.006
2. ALL CEILING HEIGHTS AT 9'-0" AFF, U.N.O. CEILING HEIGHT S ARE FROM FINISH FLOOR TO FINISH CEILING. REFER TO REFLECTED CEILING PLANS FOR HEIGHTS.
4
241
9' - 0" AFF
1
SR. MANAGER'S OFFICE
9' - 0" AFF
GUEST OFFICE
1. REFLECTED CEILING PLANS CONSTITUTE A GRAPHIC REPRESENTATION OF CEILING-MOUNTED ELEMENTS FOR THE PURPOSE OF COORDINATION. REFER TO THE APPROPRIATE DISCIPLINE FOR INFORMATION REGARDING EACH OF THESE ELEMENTS.
A-562
16
9' - 0" AFF
N.I.C. - INDICATES AREA NOT IN CONTRACT
9 12.001
A-562
A-562
OPEN WORKSTATION AREA
36 BAYS @ 5'-0" = 180' - 0"
9' - 0" AFF 12.001
9' - 0" AFF
9' - 0" AFF
OPEN WORKSTATION AREA
OPEN TO ABOVE
OA-W2
9' - 0" AFF
TEAMING
13
20
211
DIRECTOR'S OFFICE
9' - 0" AFF
TEAMING
225
215
9' - 0" AFF
SR. DIRECTOR'S OFFICE
12.001
245
12.001
22
9' - 0" AFF
23
VP OFFICE
14
224
CONFERENCE 247
WIRING CLOSET CJ 9' - 0" AFF
9' - 0" AFF
ELEVATOR 1
MENS TOILET
A-562
ELEVATOR 2
9' - 0" AFF
9' - 0" AFF A-562
9' - 0" AFF
A-562
A-562
7 A-561
ADMINISTRATIVE ASSISTANT
EXP
26
6
223
26.006
9' - 0" AFF
Checker
A-562
KITCHEN
26.006
217
COPY
27
248
A-561
MECH 203
9' - 0" AFF
FILES/ STORAGE
CJ
COATS
Murphy USA
JAN
249 09.007
28
9' - 0" AFF
216
TEAMING 222 8' - 8" AFF
14
6
A-561
A-562
210
DIRECTOR'S OFFICE
9' - 5" AFF
14
WOMENS TOILET
ELEC. 202
14
209
25
13
E-2
E-1
13
24
9' - 0" AFF
246
1
A-562
21
253
A-561
9' - 0" AFF
E.006
29
200
9' - 0" AFF 09.007
218 13
5
A-562
A-561
DIRECTOR'S OFFICE
4 9' - 5" AFF
A-562 EXP
OPEN WORKSTATION AREA
EXP
Checked by:
221
6
OA-S2
A-561
9' - 0" AFF
4
4
13
A-562
A-562
A-561 EXP
30
31
EXP
DIRECTOR'S OFFICE 6
250
A-561
SE STAIR 4 S-4
32
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
9' - 0" AFF
33
DIRECTOR'S OFFICE
9' - 0" AFF
TEAMING
251
220 9' - 0" AFF
34
9' - 0" AFF 9' - 0" AFF
219
35
9' - 0" AFF
9' - 0" AFF
DIRECTOR'S OFFICE
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
07.002 12.001
12.001 12.001
12.001
36
12.001 9' - 0" AFF
SECOND FLOOR REFLECTED CEILING PLAN
37
MM Drawn by:
EXTERIOR GRADE GYPSUM BOARD SOFFIT PANEL PAINTED. KNIFE EDGE CEILING TRIM MANUAL ROLLER SHADE CONTINUOUS LINEAR CONCEALED COLOR LED COVE LIGHTING. SEE ELECTRICAL EXISTING CEILING TO REMAIN
SR. MANAGER'S OFFICE
11
MANAGER'S OFFICE
19
##.###
9' - 0" AFF
CONFERENCE
226
18
07.002 09.007 12.001 26.006
9' - 0" AFF
OA-E2
214
6 A-431
A-562
12.001
KEYNOTES
17
13
42 BAYS @ 5'-0" = 210' - 0"
1
02 SECOND FLOOR REFLECTED CEILING PLAN 1/8" = 1'-0"
CD
A-122
PRIMARY 12/1/2015 4:16:10 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
17' - 3 1/2"
0.0
GENERAL NOTES REFLECTED CEILING PLAN
3' - 1"
0.8 1 12.001
12.001
12.001
DIRECTOR'S OFFICE
12.001
MANAGER'S OFFICE
332 9' - 0" AFF
337
333
MANAGER'S OFFICE
331
NW STAIR 1 S-1
330
3
4. WHERE FIXTURE OR DEVICES ARE SHOWN IN THE CEILING PANEL, THEY SHALL BE CENTERED IN THE PANEL UNLESS OTHERWISE INDICATED.
4
338 9' - 0" AFF
9' - 0" AFF
5
SR. MANAGER'S OFFICE
DIRECTOR'S OFFICE
EXP
9' - 0" AFF
EXP
EXP
5
EXP
7
EXP 13
4
A-562
4
COPY
A-562
CONFERENCE
6
S-2
A-561
13
A-562
CJ
355 8' - 8" AFF
329
8. IN THE EVENT OF CONFLICTS BETWEEN REFLECTED CEILING PLANS AND CORRESPONDING DISCIPLINES, BRING THE CONFLICT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.
REFLECTED CEILING PLAN LEGEND
8
SUSPENDED 2'x4' LAY-IN ACOUSTICAL CEILING TILE SUSPENDED 2'x4', 4"X4' LAY-IN TECHNICAL CEILING PANEL
9
SR. MANAGER'S OFFICE
COFFEE/ KITCHEN 356 9' - 0" AFF
341
306
14
SUSPENDED 2'x2' LAY-IN ACOUSTICAL CEILING TILE
A-562 7
WOMENS TOILET 305
A-561
10
EXP 8' - 8" AFF
11
13 A-562
3 A-561
14
MENS TOILET
A-562
304
GYPSUM BOARD CEILING, PAINTED
EXP
RECESSED ADJUSTABLE FIXTURE
A-562
308
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF 14 13
12.001
WIRING CLOSET
LAY-IN LIGHT FIXTURE
13
4" CONTINUOUS LINEAR LIGHT FIXTURE
A-562
A-562
14
327
VP OFFICE
CJ
HUDDLE 9' - 0" AFF
5 A-421
336
GUEST OFFICE
Sim
312
200' - 4 1/2"
SPRINKLER HEAD
15
OPEN WORKSTATION AREA
326 9' - 0" AFF 9' - 0" AFF
12.001
13
N.I.C. - INDICATES AREA NOT IN CONTRACT
16
A-562
OA-E3
KEYNOTES
17 13
9' - 0" AFF
A-562
340
313 OPEN TO ABOVE
12.001
MANAGER OFFICE
9' - 0" AFF
09.007 12.001 26.006
##.###
KNIFE EDGE CEILING TRIM MANUAL ROLLER SHADE CONTINUOUS LINEAR CONCEALED COLOR LED COVE LIGHTING. SEE ELECTRICAL
19
353
OPEN WORKSTATION AREA
CONFERENCE
OA-W3
311
13
18
FILES/ STORAGE
TEAMING
9' - 0" AFF
CONTROL JOINT SPEAKER - SEE A/V
TEAMING
328
36 BAYS @ 5'-0" = 180' - 0"
EXPOSED TO STRUCTURE, PAINTED SOUND ABSORBING ACOUSTICAL PLASTER ASSEMBLY
12
13
ELEC.
6. ALL SOFFITS AND BULKHEADS SHALL BE BRACED LATERALLY TO RESIST HORIZONTAL MOVEMENT.
14
A-562
A-562
5. SUSPEND ACOUSTICAL CEILING TYPICALLY 1" ABOVE ADJACENT GYPSUM WALL BOARD SOFFITS AND BULKHEADS UNLESS NOTED OTHERWISE.
7. IF A FIXTURE OR OTHER CEILING DEVICE IS NOT SHOWN OR DIMENSIONED - CONFIRM LOCATION WITH ARCHITECT.
NE STAIR 2
339 9' - 0" AFF
335
9' - 0" AFF
MECH
3. CEILING GRIDS OR TILES SHALL BE CENTERED IN SPACE UNLESS NOTED OR DIMENSIONED OTHERWISE. ALIGN CEILING GRIDS AND FIXTURES AS NOTED OR DIMENSIONED.
OA-N3 9' - 0" AFF
DIRECTOR'S OFFICE
CJ
2
DIRECTOR'S OFFICE
OPEN WORKSTATION AREA
334
9' - 0" AFF
2. ALL CEILING HEIGHTS AT 9'-0" AFF, U.N.O. CEILING HEIGHT S ARE FROM FINISH FLOOR TO FINISH CEILING. REFER TO REFLECTED CEILING PLANS FOR HEIGHTS.
9' - 0" AFF
9' - 0" AFF
DIRECTOR'S OFFICE
9' - 0" AFF
SR. DIRECTOR'S OFFICE
1. REFLECTED CEILING PLANS CONSTITUTE A GRAPHIC REPRESENTATION OF CEILING-MOUNTED ELEMENTS FOR THE PURPOSE OF COORDINATION. REFER TO THE APPROPRIATE DISCIPLINE FOR INFORMATION REGARDING EACH OF THESE ELEMENTS.
12.001
SR. DIRECTOR'S OFFICE
9' - 0" AFF
20
SR. DIRECTOR'S OFFICE
342 4
A-562
21
345
A-432 9' - 0" AFF
SR. DIRECTOR'S OFFICE 12.001
TEAMING
A-432
CONFERENCE 325
324
22
343
1
DIRECTOR'S OFFICE
12.001
314
23
SR. VP OFFICE 346
WIRING CLOSET 344
14
9' - 0" AFF
1
A-562
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
ELEVATOR 1
14
A-561 EXP
WOMENS TOILET 310
A-562
E-2
A-562
ELEC.
A-561
A-561
302
26.006
TEAMING
9' - 5" AFF
SR. DIRECTOR' S OFFICE
13
A-562
Checker
9' - 0" AFF
CJ
9' - 0" AFF
6
A-561
COFFEE
A-561
4
315
MANAGER'S OFFICE
A-561
9' - 5" AFF
348
COATS
A-562
316
A-562
EXP
Checked by:
EXP
6 A-561
OPEN WORKSTATION AREA
MANAGER'S OFFICE
ENGINEERING CONFERENCE
29
300
5
13
A-561
A-562
30
31
SE STAIR 4 S-4
A-561
SR. DIRECTOR'S OFFICE
317 9' - 0" AFF
32
33
9' - 0" AFF
34
VP OFFICE
A-561
12.001
12.001
HUDDLE
12.001
318
12.001
12.001
35
9' - 0" AFF
36
12.001
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
THIRD FLOOR REFLECTED CEILING PLAN
37
MM Drawn by:
351 9' - 5" AFF
319
Westlake Reed Leskosky
350
4
SR. MANAGER'S OFFICE
Commision #15054.00 200 Peach Street El Dorado, AR 71730
349
6
OA-S3
320
Murphy USA
JAN
COPY 8' - 8" AFF
321
28
CJ
09.007 EXP
303
9' - 0" AFF
09.007
4
EXP
MECH
8' - 8" AFF
4
A-562
MANAGER'S OFFICE
27
347 6
26
ADMINISTRATIVE ASSISTANT
26.006
322
14
25
13 5
323 8' - 8" AFF
14
9' - 0" AFF
5
7
309
ELEVATOR 2
9' - 0" AFF
9' - 0" AFF
A-562
MENS TOILET A-562
12.001
A-562
E-1
13
24
42 BAYS @ 5'-0" = 210' - 0"
1
03 THIRD FLOOR REFLECTED CEILING PLAN 1/8" = 1'-0"
CD
A-123
PRIMARY 12/1/2015 4:16:28 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
WW
17' - 3 1/2"
0.0
GENERAL NOTES REFLECTED CEILING PLAN
3' - 1"
0.8 1 12.001 12.001
OFFICE
12.001
12.001
12.001
425
OFFICE
TREASURY
424
426
12.001
12.001
12.001
12.001
VP OFFICE
OFFICE
434
436
EXPANSION
CONTROLLER
430
AUDIT 427
CHECK ROOM
S-1
423 EXP
4. WHERE FIXTURE OR DEVICES ARE SHOWN IN THE CEILING PANEL, THEY SHALL BE CENTERED IN THE PANEL UNLESS OTHERWISE INDICATED.
FILES/ WORK
4
4
4
A-562
A-562
A-562
EXP
3
5 437
NW STAIR 1
3. CEILING GRIDS OR TILES SHALL BE CENTERED IN SPACE UNLESS NOTED OR DIMENSIONED OTHERWISE. ALIGN CEILING GRIDS AND FIXTURES AS NOTED OR DIMENSIONED.
435
433
EXP
EXP
EXP
NE STAIR 2
6
CORRIDOR
A-562
6. ALL SOFFITS AND BULKHEADS SHALL BE BRACED LATERALLY TO RESIST HORIZONTAL MOVEMENT.
8. IN THE EVENT OF CONFLICTS BETWEEN REFLECTED CEILING PLANS AND CORRESPONDING DISCIPLINES, BRING THE CONFLICT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.
7
EXP
OFFICE
13
5. SUSPEND ACOUSTICAL CEILING TYPICALLY 1" ABOVE ADJACENT GYPSUM WALL BOARD SOFFITS AND BULKHEADS UNLESS NOTED OTHERWISE.
7. IF A FIXTURE OR OTHER CEILING DEVICE IS NOT SHOWN OR DIMENSIONED - CONFIRM LOCATION WITH ARCHITECT.
S-2
EXP
2. ALL CEILING HEIGHTS AT 9'-0" AFF, U.N.O. CEILING HEIGHT S ARE FROM FINISH FLOOR TO FINISH CEILING. REFER TO REFLECTED CEILING PLANS FOR HEIGHTS.
2
4
OFFICE
1. REFLECTED CEILING PLANS CONSTITUTE A GRAPHIC REPRESENTATION OF CEILING-MOUNTED ELEMENTS FOR THE PURPOSE OF COORDINATION. REFER TO THE APPROPRIATE DISCIPLINE FOR INFORMATION REGARDING EACH OF THESE ELEMENTS.
428
REFLECTED CEILING PLAN LEGEND
14
426A
A-562
CJ 9' - 0" AFF
CJ
8 SUSPENDED 2'x4' LAY-IN ACOUSTICAL CEILING TILE SUSPENDED 2'x4', 4"X4' LAY-IN TECHNICAL CEILING PANEL
9
OUTSIDE AUDITORS
FILE/ WORK MECH
429
406
COFFEE/ KITCHEN 431 8' - 8" AFF
422
CONFERENCE
TEAMING
COPY 441
442
471
14
OFFICE
OFFICE
OFFICE
439
440
7
438
405
SUSPENDED 2'x2' LAY-IN ACOUSTICAL CEILING TILE
10 GYPSUM BOARD CEILING, PAINTED
A-561
NW CORRIDOR
EXP
9' - 0" AFF
481
WOMENS TOILET
A-562
11
EXP
EXPOSED TO STRUCTURE, PAINTED
MENS TOILET COMM.
ELEC.
407
408
08.002
9' - 0" AFF 12.001
CONFERENCE
WIRING CLOSET
OFFICE
418
472
H10
14
A-561
A-615
A-562
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
9' - 0" AFF
08.002
SOUND ABSORBING ACOUSTICAL PLASTER ASSEMBLY
404
3
12 RECESSED ADJUSTABLE FIXTURE
CONFERENCE
14
444
A-562
LAY-IN LIGHT FIXTURE 4" CONTINUOUS LINEAR LIGHT FIXTURE
14
9' - 0" AFF
421
13
CJ
VP OFFICE 443
12.001
CONTROL JOINT SPEAKER - SEE A/V
15
SPRINKLER HEAD
OFFICE 415
16
OFFICE 200' - 4 1/2"
HSSE
N.I.C. - INDICATES AREA NOT IN CONTRACT
445
9' - 0" AFF
420
17 12.001
13 A-562
36 BAYS @ 5'-0" = 180' - 0"
KEYNOTES
13
OFFICE
OFFICE 416
A-562
9' - 0" AFF
12.001
A-562
18
446
OPEN TO ABOVE
13
##.###
9' - 0" AFF 9' - 0" AFF
19
08.002 12.001 12.002 E.012
ACCORDION DOOR MANUAL ROLLER SHADE MOTORIZED ROLLER SHADE. EXISTING CEILING GRID AND LIGHT FIXTURES TO REMAIN. REPLACE EXISTING ACOUSTICAL CEILING TILE WITH NEW ACT AND PAINT EXISTING GRID
9' - 0" AFF
COPY CONFERENCE
417
20
447
411
9' - 0" AFF
12.001
OFFICE
OFFICE OF THE CEO
21
449
OFFICE 414
12.001
3
9' - 0" AFF
22
WIRING CLOSET 448
A-432
INSURANCE
23
419
24
CONFERENCE 14
413
08.002
1
A-562 9' - 0" AFF
ELEVATOR 1
9' - 0" AFF
E-1 08.002
A-562
ELEVATOR 2
9' - 0" AFF
E-2 9' - 0" AFF
9' - 0" AFF
MENS TOILET 409
25
9' - 0" AFF
ELEC.
9' - 0" AFF
A-562
14
WOMENS TOILET
26
402
14 7
2
A-561
A-562
EXP
OFFICE
OFFICE
470
469
A-562
EXECUTIVE VISITING 465
410
2 9' - 3" AFF
PENTHOUSE STAIR
A-562
COPY
STORAGE
455
464
KITCHEN
TOILET
27
S-6
MECH
450
454
403
ETR
A/V ROOM
E.012
28
Murphy USA
JAN
451
29
400
TOILET 452
14 A-562 CJ
Checker
CJ
EXECUTIVE CONFERENCE
462
MEETING
463
E.012
456
LEGAL
30 9' - 0" AFF
31
E.012
Commision #15054.00 200 Peach Street El Dorado, AR 71730
468
SE STAIR 4
Checked by:
CONFERENCE
S-4
467
EXECUTIVE BOARDROOM
32
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE
WET BAR
461
460
459
458
457
11
466 9' - 0" AFF
12.002
12.002
12.002
A-562
E.012
12.002
34
35 11
E.012 12.002
12.002
A-562 12.002
11
36
A-562
12.001
Westlake Reed Leskosky
33
453 E.012
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FOURTH FLOOR REFLECTED CEILING PLAN
37
MM Drawn by:
CJ
42 BAYS @ 5'-0" = 210' - 0"
1
04 FOURTH FLOOR REFLECTED CEILING PLAN 1/8" = 1'-0"
CD
A-124
12/1/2015 4:16:44 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
17' - 3 1/2"
0.0
GENERAL NOTES REFLECTED CEILING PLAN
3' - 1"
0.8 1
2
1. REFLECTED CEILING PLANS CONSTITUTE A GRAPHIC REPRESENTATION OF CEILING-MOUNTED ELEMENTS FOR THE PURPOSE OF COORDINATION. REFER TO THE APPROPRIATE DISCIPLINE FOR INFORMATION REGARDING EACH OF THESE ELEMENTS. 2. ALL CEILING HEIGHTS AT 9'-0" AFF, U.N.O. CEILING HEIGHT S ARE FROM FINISH FLOOR TO FINISH CEILING. REFER TO REFLECTED CEILING PLANS FOR HEIGHTS. 3. CEILING GRIDS OR TILES SHALL BE CENTERED IN SPACE UNLESS NOTED OR DIMENSIONED OTHERWISE. ALIGN CEILING GRIDS AND FIXTURES AS NOTED OR DIMENSIONED.
3
4. WHERE FIXTURE OR DEVICES ARE SHOWN IN THE CEILING PANEL, THEY SHALL BE CENTERED IN THE PANEL UNLESS OTHERWISE INDICATED.
4
5. SUSPEND ACOUSTICAL CEILING TYPICALLY 1" ABOVE ADJACENT GYPSUM WALL BOARD SOFFITS AND BULKHEADS UNLESS NOTED OTHERWISE.
5
6. ALL SOFFITS AND BULKHEADS SHALL BE BRACED LATERALLY TO RESIST HORIZONTAL MOVEMENT. 7. IF A FIXTURE OR OTHER CEILING DEVICE IS NOT SHOWN OR DIMENSIONED - CONFIRM LOCATION WITH ARCHITECT.
6 8. IN THE EVENT OF CONFLICTS BETWEEN REFLECTED CEILING PLANS AND CORRESPONDING DISCIPLINES, BRING THE CONFLICT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION.
7
8
REFLECTED CEILING PLAN LEGEND SUSPENDED 2'x4' LAY-IN ACOUSTICAL CEILING TILE
9 SUSPENDED 2'x4', 4"X4' LAY-IN TECHNICAL CEILING PANEL
10
SUSPENDED 2'x2' LAY-IN ACOUSTICAL CEILING TILE GYPSUM BOARD CEILING, PAINTED
11 EXP
12
EXPOSED TO STRUCTURE, PAINTED SOUND ABSORBING ACOUSTICAL PLASTER ASSEMBLY RECESSED ADJUSTABLE FIXTURE
13 LAY-IN LIGHT FIXTURE
14
4" CONTINUOUS LINEAR LIGHT FIXTURE CJ
15
CONTROL JOINT SPEAKER - SEE A/V SPRINKLER HEAD
200' - 4 1/2"
16 N.I.C. - INDICATES AREA NOT IN CONTRACT
17
36 BAYS @ 5'-0" = 180' - 0"
KEYNOTES ATRIUM
##.###
18
P-10
19
20 EXISTING TO REMAIN
21
22
23
24
25
26
STORAGE-2 P-05 ETR
MECH P-04 ETR
ELEVATOR PENTHOUSE
MECH 27
P-02
P-03
ETR
STORAGE -1 P-01
ETR
ETR
28
29
Murphy USA
Checker
30
31
Checked by:
32
Westlake Reed Leskosky
33
34
35
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
PENTHOUSE FLOOR REFLECTED CEILING PLAN
37
MM Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
42 BAYS @ 5'-0" = 210' - 0"
1
05 PENTHOUSE FLOOR REFLECTED CEILING PLAN 1/8" = 1'-0"
CD
A-125
12/1/2015 4:17:21 PM
WW
VV
UU
TT
SS
RR
PP
NN
MM
LL
KK
JJ
HH
GG
FF
EE
DD
CC
BB
AA
X
W
V
U
T
S
R
Q
P
N
M
L
K
J
H
G
F
E
D
C
B
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
A TOP OF LIMESTONE 2 72' - 8"
D.043
D.043
D.043
BOTTOM OF LIMESTONE 64' - 0" TOP OF LIMESTONE 57' - 8"
General Notes 1. 2.
SEE SHEET A-106 FOR ALTERNATE #2. SEE STRUCTURAL DRAWINGS FOR STEEL CANOPY GEOMETRY.
04 FOURTH FLOOR 40' - 0"
KEYNOTES 05.017 05.019
03 THIRD FLOOR 26' - 8" 1
2
A-310
A-310
3
4
A-310
A-310
08.008 26.001 26.007 D.043 08.008
07.001
08.006
07.001 07.017 08.003 08.006
08.006
3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING STANDING SEAM ZINC ROOF OVER INSULATED STEEL DECK ZINC COMPOSITE MATERIAL PANEL REVOLVING DOOR SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED GLASS TYPE 6. SEE GLASS TYPE LEGEND LIGHT FIXTURE - SEE ELECTRICAL LED STEPLIGHT REMOVE EXISTING LOUVER FOR NEW LOUVER REPLACEMENT - SEE ROOF PLAN AND MECH.
02 SECOND FLOOR 13' - 4"
GLASS TYPES
05.019
NOTE: TYPES BELOW ARE INDICATED FOR CONVIENENCE. SEE TECHNICAL SPECIFICATION SECTION 088000 FOR GLASS TYPE DESCRIPTIONS.
6 A-201
26.001
05.017
05.017
ALIGN
26.007
1
3/8" CLEAR, FULLY TEMPERED GLASS
2
9/16" CLEAR, LAMINATED GLASS
3
1/2" CLEAR, FULLY TEMPERED - LOW IRON
4
9/16" CLEAR, LAMINATED GLASS - LOW IRON
5
CLEAR, FIRE-RATED SAFETY GLASS
6
5/8" LAMINATED SAFETY GLASS, SELF CLEANING COATING ON TOP SURFACE, 80% LIGHT TRANSMISSION PVB INTERLAYER
7
10-5/16" LOW IRON, TEMPERED CHANNEL GLASS SYSTEM (DOUBLE GLAZED IN CURVED TRACK)
8
1" CLEAR, TEMPERED INSULATED GLASS UNIT (IGU)
T
TEMPERED (SEE ELEVATIONS FOR LOCATIONS)
01 FIRST FLOOR 0' - 0"
05.017
BLANK OFF EXISTING LOUVER
00 BASEMENT -14' - 0"
8
BUILDING ELEVATION - NORTH
GLASS NOTES:
1/8" = 1'-0"
1. 2.
0.0 0.8
0.8
3.
1
0.0 QQ
PP
NN
MM
LL
KK
JJ
HH
GG
4.
FF
5. 5' - 5"
6' - 4"
6' - 4"
5' - 5"
7
02 SECOND FLOOR 13' - 4"
A-502
A-502 07.017
9
A-615
A-615
1 1
A-502
A-615
1
1
1
1
1
1
1
1
1
1
1
8' - 10"
1
8' - 10"
10' - 10"
9
7
02 SECOND FLOOR 13' - 4"
A-502
07.017
3
6.
OPP.
7
9
4' - 5"
ULTRA-QUICK DRYING TYPE SEALANT MUST BE USED FOR ALL GLASS LAMINATE LOCATIONS. ALL SEALANTS AT BUTTGLAZED JOINTS TO BE TRANSLUCENT COLOR U.O.N. ALL GLASS IN DOORS, ADJACENT TO DOORS AND WITHIN 18" FROM FLOOR MUST BE SAFETY GLASS (TEMPERED OR LAMINATED). ALL GLASS OVERHEAD MUST BE SAFETY GLASS (LAMINATED TYPE ONLY). ALL EXTERIOR INSULATED GLAZING MUST MEET OR EXCEED LOCAL AND FEDERAL ENERGY CODES. SHOP DRAWINGS ARE REQUIRED FOR ALL GLAZING AND ALL SIZES TO BE VERIFIED BASED ON FIELD CONDITIONS U.O.N.
1
1 1
7
3
A-502
A-615
A-502
6' - 0" 5' - 0"
5' - 0"
5' - 0"
5' - 0"
OPP.
6
01 FIRST FLOOR 0' - 0" 1' - 2"
5' - 0"
5' - 0"
5' - 0"
5' - 0"
5' - 0"
10' - 10"
4' - 5"
##.###
EQ
01 FIRST FLOOR 0' - 0"
EQ
1' - 2"
CLEAR ANODIZED ALUMINUM FRAME
CLEAR ANODIZED ALUMINUM FRAME CLEAR ANODIZED ALUMINUM FRAME
7
ENLARGED ELEVATION
6
1/4" = 1'-0"
ENLARGED ELEVATION
5
1/4" = 1'-0"
ENLARGED ELEVATION 1/4" = 1'-0"
Murphy USA
6 08.003
Checked by:
A-615
1
T
V
6
4
A-615
A-615
MM Drawn by:
A-501
1
3
3
A-615
A-615
1
1
A-501
A-615
H
4
4
A-501
A-615
1
1
A-501
A-615
EXISTING OPENING
EXISTING OPENING
EXISTING OPENING
ENLARGED ELEVATION 1/4" = 1'-0"
X
AA
BB
5 A-615
08.003
ENLARGED ELEVATION 1/4" = 1'-0"
1
2
2
A-615
A-615
01 FIRST FLOOR 0' - 0"
27' - 6" VIF EXISTING OPENING CLEAR ANODIZED ALUMINUM FRAME
DARK BRONZE ANODIZED ALUMINUM FRAME
2
W
1
12' - 6" VIF
DARK BRONZE ANODIZED ALUMINUM FRAME
V
A-615
1
12' - 6" VIF
3
5
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
27' - 6" VIF
ENLARGED ELEVATION - NORTH ENTRY 1/4" = 1'-0"
J
4
1
CLEAR ANODIZED ALUMINUM FRAME
4
S
EXISTING OPENING
W
9' - 0" VIF
X
EXISTING OPENING
AA
9' - 0" VIF
Checker
BB
1
01 FIRST FLOOR 0' - 0"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
EXTERIOR ELEVATIONS
ENLARGED ELEVATION - SOUTH ENTRY 1/4" = 1'-0"
CD
A-201
12/1/2015 4:18:11 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
KEYNOTES 05.001 05.006 05.014 08.010 08.011 21.001
STEEL PANELS AT THIS LOCATION TO BE FURRED-OUT FLUSH WITH EXISTING GLASS ELEVATOR ENCLOSURE.
##.###
STEEL BEAM W/2 HR. SPRAY-ON FIREPROOFING - SEE STRUC. REPLACE EXISTING GLAZING STANDOFFS WITH STAINLESS STEEL STANDOFFS LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD 1/2" TEMPERED, LOW-IRON GLASS GLASS GUARDRAIL W/S.S. STANDOFFS GLASS PARTITION AT ATRIUM ENCLOSURE - SEE F-DWGS FOR SPRINKLER REQUIREMENTS.
4 A-441
4' - 0"
PENTHOUSE ROOF 70' - 4"
15' - 7 1/2"
PENTHOUSE ROOF 70' - 4"
NOTE: HAIRLINE BASE JOINTS - TYP.
14' - 8 1/2"
08.010 TYP. 05.014
05.014
05 PENTHOUSE FLOOR 54' - 8 1/2"
11' - 0"
05 PENTHOUSE FLOOR 54' - 8 1/2"
NOTE: 08.011 TYP.
2
NOTE: 3/4" JOINTS AT CEILING - TYP.
4
MAINTAIN HORIZ. JOINTS AROUND CORNERS
A-441
A-432
04 FOURTH FLOOR 40' - 0"
04 FOURTH FLOOR 40' - 0"
13' - 4"
NOTE: TEAMING
9 A-511
OPEN WORKSTATION AREA
ALIGN FACES OF GLASS AND STEEL PANELS
314
OA-W3
03 THIRD FLOOR 26' - 8"
11 ALIGN JOINTS TYP.
03 THIRD FLOOR 26' - 8"
13' - 4"
A-561
OPEN WORKSTATION AREA
OPEN WORKSTATION AREA
05.006
TEAMING
TYP.
215
OA-E2
OA-W2
02 SECOND FLOOR 13' - 4"
12
02 SECOND FLOOR 13' - 4"
13' - 4"
A-562
21.001
ATRIUM
21.001
111
01 FIRST FLOOR 0' - 0" 5' - 0"
4
5' - 0"
5' - 0"
5' - 0"
3' - 9" 2' - 6" 3' - 9"
5' - 0"
5' - 0"
5' - 0"
5' - 0"
01 FIRST FLOOR 0' - 0"
3' - 9"
21.001
ATRIUM - W 3
1/8" = 1'-0"
21.001 EXISTING ELEVATOR GLASS ENCLOSURE
ATRIUM - S 1/8" = 1'-0"
PENTHOUSE ROOF 70' - 4"
PENTHOUSE ROOF 70' - 4"
4 A-441
05 PENTHOUSE FLOOR 54' - 8 1/2"
05 PENTHOUSE FLOOR 54' - 8 1/2"
05.001
TYP.
Murphy USA
05.014
04 FOURTH FLOOR 40' - 0"
OPEN WORKSTATION AREA
9 A-511
9 A-511
Commision #15054.00 200 Peach Street El Dorado, AR 71730
05.014 TYP.
TEAMING 312
OA-W3
03 THIRD FLOOR 26' - 8"
Checked by:
Checker
04 FOURTH FLOOR 40' - 0"
03 THIRD FLOOR 26' - 8"
OPEN WORKSTATION AREA
TEAMING 213
OA-E2
02 SECOND FLOOR 13' - 4"
02 SECOND FLOOR 13' - 4"
ALIGN JOINTS - TYP.
Author
OPEN WORKSTATION AREA
Drawn by:
OA-E1
OA-W1
3' - 8"
2
5' - 1"
ATRIUM - E 1/8" = 1'-0"
5' - 0"
5' - 0"
5' - 0"
3' - 9" 2' - 6" 3' - 9"
5' - 0"
5' - 0"
01 FIRST FLOOR 0' - 0"
01 FIRST FLOOR 0' - 0" SEE SHEET A-421 FOR STAIR
1
ATRIUM - N 1/8" = 1'-0"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
BUILDING SECTIONS
OPEN WORKSTATION AREA
12 A-562
Westlake Reed Leskosky
CD
A-301
12/1/2015 4:18:24 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
General Notes 1. 2.
4
3.9
3
2
1' - 0"
1
0.8
0.0
17' - 6"
7' - 3 1/2"
EQ
11 A-501
6' - 3"
3' - 9"
1
2' - 6"
2' - 6"
0.8
0.0
6"
KEYNOTES
##.###
EQ 10 A-501
3 A-501 1 3/4" / 1 '-0"
7' - 10 1/2" 7 A-501
8 A-501
08.006 08.006
23' - 4 1/2"
10 A-501
26.008 05.019
03.001 03.007 03.012
6' - 3"
1 3/4" / 1 '-0"
08.006
10 A-501
3' - 9"
08.006
2' - 6"
05.002
3' - 0"
02 SECOND FLOOR 13' - 4"
7 A-501
8 A-501
05.016 05.017
2' - 4"
5
SEE SHEET A-106 FOR ALTERNATE #2. SEE STRUCTURAL DRAWINGS FOR STEEL CANOPY GEOMETRY.
05.018
26.008
26.008
05.019
5 05.024 05.025 05.040 07.001 07.002 07.004 07.005 07.007
A-501 05.019
08.006 05.040
05.019
05.019 07.007
8
A-422
08.004
A-422 2 A-503
05.017
10 A-503
05.017
08.021 09.001 26.007 26.008 26.010 32.001
05.025
32.002
05.018
2 A-501
05.002 1 A-615
08.004 08.006
11' - 0"
3
8 A-503
32.002
32.001
NEW SLAB ON GRADE. - SEE STRUCTURAL COMPACTED GRANULAR BASE NEW CAST IN PLACE CONCRETE RETAINING WALL AND FOUNDATION. SEE STRUCT. STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. STAINLESS STEEL RAILING 2" X 3/4" BAR STOCK 3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH AESS TUBE SECTION W/ HIGH PERFORMANCE COATING. SEE STRUCTURAL. CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING STEEL ANGLE - SEE STRUCT. COLD FORM METAL FRAMING HSS 6"X4"X1/4" - SEE STRUC. STANDING SEAM ZINC ROOF OVER INSULATED STEEL DECK EXTERIOR GRADE GYPSUM BOARD SOFFIT PANEL PAINTED. VAPOR BARRIER 3" RIGID INSULATION AT PERIMETER 2" X 3" ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER SEE CIVIL SSG ALUMINUM CURTAIN WALL SYSTEM SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED ACCESSIBLE PUSH BUTTON AUTOMATIC DOOR OPENER SUSPENDED GYPSUM BOARD CEILING LED STEPLIGHT LINEAR LED LUMINAIRE LED DOWNLIGHT - SEE ELECTRICAL THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB.
01 FIRST FLOOR 0' - 0" 03.012
EXISTING CONCRETE BEAM
32.002
EXISTING COMPOSITE STEEL AND CONCRETE DECK
WALL SECTION - CANOPY SECTION - N2
4
3
3/8" = 1'-0"
7
6
5
4
3
2
1
0.8
WALL SECTION - CANOPY SECTION - NW 3/8" = 1'-0"
1
0.0
0.8
0.0
10 A-502
3 A-501 7' - 10 1/2"
10' - 0"
17' - 10 1/2"
VARIES
8' - 0" 07.001
08.006 10 A-501
05.024
05.024
6 A-501
7 A-501
9 A-501
7 A-501
1 3/4" / 1 '-0"
9 A-502
Murphy USA
26.008 05.019
Checker
05.019 07.002
9 A-561
26.010
Checked by:
05.002
08.021 1' - 0"
05.016
7
2
A-422
A-422
08.004
03.007
A-503
1/8" / 1'-0"
6 A-502
05.025 05.017
32.002
03.007
07.004
03.001
07.005
WALKWAY SEE LANDSCAPE
26.007 05.017 05.017
MM
1" / 1'-0"
Drawn by:
WALL SECTION - CANOPY SECTION - N 3/8" = 1'-0"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
WALL SECTIONS
03.012
CD
SEE LANDSCAPE
2
Westlake Reed Leskosky
05.018
05.016
11 32.002
Commision #15054.00 200 Peach Street El Dorado, AR 71730
09.001
1
WALL SECTION - ENCLOSED PATIO 3/8" = 1'-0"
A-310
EQUIPMENT SCHEDULE
LAVATORY MOUNTED SOAP DISPENSER WALL MOUNTED SOAP DISPENSER GRAB BARS
BOBRICK, B-822 BRADLEY CORP, 6563
C1 C2 C3 C4 D E1 E2
PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER SEMI-RECESSED NAPKIN/TAMPON VENDOR COMBINATION UNIT CLASSIC SERIES SURFACE MOUNTED SEAT COVER DISPENSER MIRROR
BOBRICK, B-39003 BOBRICK, B-38032 BOBRICK, B-35903 WP255 DOLPHIN PRESTIGE PAPER TOWEL DISPENSER BOBRICK, B-3706 25 BRADLEY CORP, 591-000000 BOBRICK, B-221
G H
COPIER REFRIGERATED DISPLAY CASE
J1 J2 K L M N O1 O2 P Q R S
MICROWAVE MICROWAVE ICED TEA MACHINE COFFEE MAKER UNDER COUNTER ICE MAKER OVEN/STOVE REFRIGERATOR COFFEE / KITCHEN REFRIGERATOR VENT-A-HOOD DISHWASHER ICE MACHINE U.C. TRASHCAN ASSEMBLY
T
DIMENSIONS W
H
4 13/16"
3 5/16" 3 3/4"
14 5/8" 8 3/16"
COUNTERTOP-MOUNTED CIRCULAR WASTE CHUTE
MIRRORED GLASS, FRAMELESS, MOUNTED WITH CONCEALED FASTENERS CANON IMAGERUNNER ADVANCE C5250 WITH FINISHER 24" MARVEL LOW PROFILE BEVERAGE REFRIGERATOR ADA HEIGHT, MODEL NO. MA24BRG3 GENERAL ELECTRIC, MODEL NO. JES2051DN1WW, SERIAL NO. FS 903010 GE PROFILE SERIES 2.2 CU. FT.COUNTERTOP MICROWAVE OVEN BUNN TB3 SERIES SUMMIT BIM44GADA GENERAL ELECTRIC, MODEL NO. JB960C0B4CC, SERIAL NO. ZZ2 67918Q GE PROFILE, MODEL NO. PFS22MBSAWW, SERIAL NO. HH045850 LIEBHERR FREESTANDING 24" STAINLESS STEEL REFRIGERATOR WHIRLPOOL, MODEL NO. RH2630XJT0, SERIAL NO. FRL08 80867 KENMORE, MODEL NO. 665.13092N410, SERIAL: F44309289, TYPE:583-1 KOLD DRAFT, MODEL NO. GT551AHK REV-A-SHELF DOUBLE BOTTOM MOUNT ALUMINUM WASTE CONTAINERS, MODEL NO. 5349-2150DM - 50QT - BRUSHED / WHITE BOBRICK B-532
MEP+T REQUIREMENTS PROVIDED BY
8 3/16" 6 1/4" 13" 3 15/16" 13 7/8" 17 1/8"
17 1/4" 13" 3 3/4" 11 23/32" 7 15/16" 4 1/2"
56" 55 1/8" 18 15/16" 5 27/32" 27 7/8" 30 5/8"
15 3/4"
2"
11"
18"
1/8"
SPEC SECTION
INSTALLED BY
CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR
ALIGN DEVICES ALONG CENTERLINE
COMMENTS
REFER TO TYPICAL FIXTURE AND ACCESSORIES MOUNTING HEIGHTS (1/A-410) FOR DIMENSIONS
CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR
5"
T
3"
33 1/2"
24 3/8"
28 1/8"
23 7/8"
25 5/8"
31 1/8"
19 1/4" 24 1/8" 23"
23 7/8" 19 3/4" 12"
13 5/8" 14" 34"
14 1/2" 30" 33 7/8" 24 13/16" 17 5/8" 24" 34"
ID
22.001 F
A1
GENERAL NOTES ENLARGED PLANS & ELEVATIONS
T-4
1.
CONTRACTOR CONTRACTOR FP
23 1/2" 25 3/8" 34 13/16" 23 5/8" 30" 25 3/16" 42 1/2"
LEGEND FS = FIRE ALARM STROBE T = THERMOSTAT ID - ROOM ID PLAQUE (NIC) FP = FIRE ALARM PULL STATION L = SWITCH CR = CARD READER PP = PUSH PLATE T/D = TELE-DATA P = POWER RECEPTACLE
FS
OWNER OWNER CONTRACTOR CONTRACTOR OWNER CONTRACTOR OWNER OWNER CONTRACTOR OWNER OWNER CONTRACTOR OWNER OWNER OWNER CONTRACTOR
32 3/8" 46 1/2" 69" 79 3/16" 6" 34 1/2" 66 3/4"
15" 60 5/16"
CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR
PP
CR
2.
L
EQ EQ EQ
T/D
GUIDELINES IF t IS LESS THAN OR EQUAL TO 3'-0", X=t/2
P
EQ
2' - 6"
EQ
E.016
t
25
1
2
A-533
A-533 09.020 09.021 22.001 22.002 22.003 22.004 E.015 E.016
TOILET 454 - W 1/4" = 1'-0"
1/2" = 1'-0"
FF
KK
T
-DENOTES WALL FINISH
X
DENOTES EQUIPMENT - REFER TO SHEET A-401 FOR EQUIPMENT LIST
KEYNOTES
TYPICAL DEVICE MOUNTING LOCATIONS JJ
X
1 1/2"
X
CONTRACTOR CONTRACTOR
FURNITURE PROVIDED FOR REFERENCE ONLY - REFER TO I-200 SERIES FOR FURNITURE PLANS REFER TO I-100 SERIES FOR ROOM FINISH SCHEDULE AND FINISH PLANS.
5' - 3 1/8"
IF t IS GREATER THAN 3'-0", X = 1'-0"
EQ
18"
A1 A2 B
F
L
BASIS OF DESIGN
4' - 0"
DESCRIPTION
5' - 0"
ID
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
EDGE OF DOOR FRAME, WINDOW FRAME, OR WALL CORNER
6' - 11 1/2"
12/1/2015 4:18:42 PM
PRIMARY
LL
##.###
REFINISH PARTITIONS, SEE FINISH SCHEDULE REFINISH CABINETS, ALT #3 TOILET, SEE PLUMBING SINK, SEE PLUMBING DRINKING FOUNTAIN, SEE PLUMBING URINAL, SEE PLUMBING EXISTING URINAL TO REMAIN EXISTING TOILET TO REMAIN
GG T-4
14
27
29
21 25
A-401
22
A-401
T-4
T-4
T-4
13
C4
T
20
12
19
28
30
T
TOILET 452 - W
22 ENLARGED PLAN - TOILET 454
24
14
23
1/4" = 1'-0"
21
1/4" = 1'-0"
TOILET 454 - N
TOILET 454 - E
20
1/4" = 1'-0"
TOILET 454 - S
19
1/4" = 1'-0"
1/4" = 1'-0"
ENLARGED PLAN - TOILET 452 1/4" = 1'-0"
A-562 F
F
C1 F
09.021
F
T-4 1' - 4" 2' - 2"
T-4
T-4 C4
T-4
T-4
T-4
09.020 A1
22.002 4' - 0"
SSM-2
E.015 09.021 E.016
A1
A1 8
22.001
B
22.001
ADA
A-533
18
22.004
E2
22.002
MENS TOILET - E
ADA E1
B
16
E2
MENS TOILET - S
1/4" = 1'-0"
MENS TOILET - N
14
1/4" = 1'-0"
MENS TOILET - W
17
1/4" = 1'-0"
15
22.002
A1
E.015
E.016
E.015
TOILET 452 - N
13
1/4" = 1'-0"
TOILET 452 - E
12
1/4" = 1'-0"
E.016
TOILET 452 - S 1/4" = 1'-0"
14 A-562
C1
1/4" = 1'-0"
F
F
D
2' - 2" 1' - 4"
3' - 0"
T-4
T-4
B
T-4
T-4
22.002 4' - 0"
MENS TOILET 17
2' - 9"
22.001
8
A1
A1
WOMENS TOILET - E
11
10
1/4" = 1'-0"
3' - 2"
D
22.001
7' - 8"
22.001
E2
B
ADA
F
5' - 1"
5' - 0"
7' - 11"
A-533
3' - 0" 18
1' - 6"
1' - 6"
3' - 2"
F
16
A-401
10"
5' - 0"
SSM-2
E2
15 4' - 2"
109
E1
PP
WOMENS TOILET - N
9
1/4" = 1'-0"
WOMENS TOILET - S
8
1/4" = 1'-0"
WOMENS TOILET - W 1/4" = 1'-0"
A 7' - 11"
J
F
11
A-411
4' - 9 7/8" 5' - 0"
2' - 11"
22.003
F 10
2
4' - 1"
8 5' - 0"
2' - 11 1/2" 2' - 10 1/2"
A-401
11
1' - 0"
3
9
Checked by:
2' - 6"
F T
Checker
110
114A
5
A-401
WOMENS TOILET
C2
LOBBY TOILET ROOM
4 9' - 8 3/4"
1' - 6"
31
114A
3' - 2"
5' - 1"
T
CHASE WIDTH 10 3/8"
1' - 6"
1' - 6"
A
TYPICAL ENLARGED TOILET ROOM
6
1/4" = 1'-0"
T-4
32
A2 22.002
E2
1/4" = 1'-0"
5
LOBBY TOILET ROOM - E
LOBBY TOILET ROOM - N
4
1/4" = 1'-0"
11
ADA
A-533
LOBBY TOILET ROOM - S
3
1/4" = 1'-0"
22.001
1/4" = 1'-0"
Drawn by:
STANDARD URINAL
ADA URINAL
STANDARD ADA WATER WATER CLOSET CLOSET
SINK
A1
A2
B
TYPICAL FIXTURE AND ACCESSORIES MOUNTING HEIGHTS 1
Typical Mounting Heights 1/4" = 1'-0"
C1
C3
D
E1
E2
F
7" - 9"
16"-18"
1' - 3" MIN
OC
C2 ACCESSIBLE STALL SIDE WALL ELEVATION
ACCESSIBLE STALL REAR WALL ELEVATION
0' - 6" MAX 0' - 8" MIN TOE CLEARANCE KNEE CLEAR1' - 7" ANCE MIN DEPTH TYP. LAVATORY DIMENSIONS
TO BOTTOM OF REFLECTING SURFACE
3' - 4" MAX
TO SURFACE
2' - 10"
TO APRON
2' - 5"
TO SINK BOTTOM
2' - 3"
TOE CLEAR.
2' - 10"
3' - 0"
MIN
TO CONTROLS 1' - 7 3/16"
3' - 4"
BOTTOM OF REFLECTING SURFACE
40" MAX
2.00 MIN 31"
TO CONTROLS
6"
3' - 4" MAX
40"
37"
34"
34"
19"
16"
MAX
19"
24"
MAX
42"
40" CL OF DISPENSER
EX
PARTITION MOUNTED
60"
18"
AH
EXISTING TO REMAIN
1' - 0"
0' - 9" MIN
3' - 6"
CORNER
Westlake Reed Leskosky 2
LOBBY TOILET ROOM - W 1/4" = 1'-0"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
5' - 4 1/4" CONTROLS LOCATED 38" - 48" A.F.F. GIVE EASY ACCESS FOR ALL USERS
MAX 6"
Commision #15054.00 200 Peach Street El Dorado, AR 71730
ADA
ENLARGED PLAN - LOBBY TOILET ROOM
Murphy USA
F
B
B
5' - 0"
MAX 12"
T-4 A2
33
7
T-4
T-4
ENLARGED RESTROOM PLANS & ELEVATIONS
CD
A-401
5 26.001
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
5 A-533
A-533
2' - 6"
IPT-2
PL-1 PL-1
6"
PL-1
6"
12/1/2015 4:19:08 PM
PRIMARY
G
G
G
G
G
G
12.003 IPT-2
SSM-1
GENERAL NOTES ENLARGED PLANS & ELEVATIONS
2' - 10"
5' - 6"
7' - 0"
5' - 6"
7' - 0"
12.003
1' - 8"
IPT-2
PL-1 EQ
EQ
1.
EQ
2.
6
9' - 9 1/2"
A-533
29
COATS COPY - N
28
1/4" = 1'-0"
COATS 316-N
27
1/4" = 1'-0"
COPY 216 - E
COPY 349 - S
26
1/4" = 1'-0"
COPY 355 - S
25
1/4" = 1'-0"
COPY 441 - S
24
1/4" = 1'-0"
FURNITURE PROVIDED FOR REFERENCE ONLY - REFER TO I-200 SERIES FOR FURNITURE PLANS REFER TO I-100 SERIES FOR ROOM FINISH SCHEDULE AND FINISH PLANS.
X
1/4" = 1'-0" X
5
-DENOTES WALL FINISH DENOTES EQUIPMENT - REFER TO SHEET A-401 FOR EQUIPMENT LIST
A-533 5
5
13' - 9"
A-533
EQ
EQ
EQ
A-533
EQ
H
C3
H
KEYNOTES
5
O2
J2
L
22.002
A-533
K 12.003
IPT-2
SSM-1
7 A-533
PL-1
PL-1 EQ
EQ
EQ
EQ
9' - 10 1/8"
6' - 10 1/2" 6
EQ
EQ
6' - 10 1/2"
EQ
EQ
12' - 1 1/8"
6
G
A-533
23
EQ
7' - 0 3/8"
EQ
1' - 3"
4' - 0"
6
3
A-533
A-533
EQ
9' - 8"
22
2' - 2 5/8"
4
3' - 6"
1/4" = 1'-0"
3' - 6"
COPY 234 - W
21
1/4" = 1'-0"
20
1/4" = 1'-0"
KITCHEN 431 - E
A-533
15' - 10 1/8"
1
COFFEE / KITCHEN 431 - S
19
1/4" = 1'-0"
M
6' - 7 1/2"
A-533
COPY 131 - E
S
2"
A-533
COPY 417 - E
22.002 22.005 26.001 26.009
1' - 3"
2' - 10"
SSM-1 PL-1
2' - 1"
COAT CLOSET; PROVIDE CHROME ROD AND HIGH-PRESSURE LAMINATE SHELF, CONTINUOUS SINK, SEE PLUMBING BOTTLE FILLING STATION - SEE PLUMBING LIGHT FIXTURE - SEE ELECTRICAL UNDER CABINET LIGHTING, SEE ELECTRICAL
2' - 11"
2' - 6"
OPEN TO BEYOND
1' - 8"
PL-1
T-5
ALIGN
2' - 10"
SSM-1
PL-1
1' - 8"
2' - 6"
4' - 2 1/16"
SSM-1 2' - 10"
PL-1
PL-1
2' - 10"
2' - 8 1/16" 1' - 6"
SSM-1
PL-1
2' - 10"
2' - 10" 1' - 8 1/16" 2' - 6"
PL-1
1 5/8"
IPT-2
2' - 10"
IPT-2
IPT-2
##.###
A-533
COFFEE / KITCHEN 431 - N
18
1/4" = 1'-0"
2
1/4" = 1'-0"
5 H
O2
A-533
PL-1
PL-1 EQ
EQ EQ
4' - 0 1/8" 3
4' - 0 1/2"
A-533
7' - 3"
KITCHEN 356 - E 1/4" = 1'-0"
1' - 3" 2' - 11"
S
ALIGN
M
1' - 5 1/2"
2"
EQ 2' - 3 3/4"
4
3' - 6"
3' - 6"
A-533
1/4" = 1'-0"
1' - 0"
EQ
1' - 4"
4' - 0"
2' - 5 1/2"
KITCHEN 315 - W
14
KITCHEN 217 - W
13
1/4" = 1'-0"
KITCHEN 217 - E
12
3
4
A-533
A-533
1/4" = 1'-0"
1/4" = 1'-0"
1/4" = 1'-0"
V
W
L
K
N
A-533
K
A-533
P
L
REF
KK 1' - 9"
1 5/8"
2' - 1 3/4"
2' - 5"
3' - 0"
3' - 0"
3' - 6"
16' - 8 1/4"
1 A-533
M
2"
2' - 7 1/2"
EQ
2' - 11"
EQ
3' - 0"
2' - 6"
T-5
J1 J1
SSM-1 PL-1
3' - 6"
3' - 6"
1' - 3" 3' - 0" 1' - 0 1/4"
PL-1
3' - 6"
Q
3' - 0"
2' - 10"
2' - 10"
2' - 5 1/2"
1 1/4"
7 3/8"
2' - 11 3/4"1' - 6 1/4" 2' - 6"
T-4 S
MM
NN
PP
18
FE 2' - 11 3/4"1' - 6 1/4" 2' - 6"
1' - 2"
2' - 6"
LL
PL-1
3' - 8 1/4"
1' - 3"
3' - 0"
O1
SSM-1
PL-1
22.002
IPT-2 2' - 11"
2' - 11"
T-5
22.002
1' - 8"
PL-1
1 3/4"2' - 0"
2' - 6"
1' - 0"
C3
IPT-2
2 3/8"
3' - 6"
1' - 6" 2' - 0"
2
1
1
A-533
A-533
A-533
3' - 6"
14' - 0 1/2"
20
A-402 19
9
STORAGE T-5
D
10
133B 10' - 0"
SSM-1
3' - 0 3/16"
R
PL-1
10
S
11 1/8"
9
13' - 8 3/8"
3' - 0"
A-533
2' - 1"
5
5
X
A
26.009
J2
EQ
KITCHEN 217 N
11 U
O2
PL-1
A-533
1/4" = 1'-0"
5
SSM-1
9' - 8"
2
COFFEE/KITCHEN 356 - N
15
A-533
6' - 1 1/2"
15' - 5 1/4"
1
KITCHEN 356 - S
16
L 7
A-533
17
H
K
2' - 10"
2' - 10"
7
2' - 10"
SSM-1
H
C3
1' - 0"
2' - 6"
T-5
SSM-1
2' - 2"
1' - 8"
ALIGN
22.002 C3
1 3/4" PL-1
A-533
J2
IPT-2
2' - 10"
H
C3
COFFEE/ KITCHEN
3' - 4 1/8"
11
431 22.005
2 A-533 9 3/4" 18' - 0 3/8"
KITCHEN 217 - S
9
1/4" = 1'-0"
KITCHEN 134 - S
8
1/4" = 1'-0"
U
1/4" = 1'-0"
V
W
KITCHEN 134 - E
6
1/4" = 1'-0"
A-402
2' - 0 7/8"
EQ
V
BB
W ALIGN
10' - 0"
ALIGN
1' - 3"
AA
BB
CC
Commision #15054.00 200 Peach Street El Dorado, AR 71730
ALIGN
16' - 8 1/4"
EQ
H
10' - 0"
EQ
1' - 3"
1' - 3"
27
REF
17
10
14
315
H
A-402
14' - 7 1/2"
H
7' - 7"
EQ
11
H
13' - 9"
2' - 0 3/4"
29
H 28
316
ENLARGED PLAN
12
14' - 7 3/8"
26.009
ENLARGED PLAN 1/4" = 1'-0"
2
ENLARGED PLAN 1/4" = 1'-0"
1' - 11 7/8"
216
A-402
28
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
29
ENLARGED PLANS & ELEVATIONS
H 27
218
A-402
30
FE
3
COPY
H
G
COATS 29
F2
30
A-402 A
A-402 10
26.009
COATS
13
3' - 0"
3' - 0"
22.005 EQ
1' - 3"
7
1' - 3"
1' - 6"
2' - 6"
2' - 6"
217
10 16
356
2' - 1"
6
A-402
COFFEE
2' - 1"
3' - 11"
13' - 11 7/8"
COFFEE/ KITCHEN
13' - 2 1/8"
9 1/2"
KITCHEN 3' - 9 3/8"
15
11
H
11 2' - 3 3/4"
3' - 0"
1' - 3"
28
Westlake Reed Leskosky
22.005
3' - 0"
D
FEC1
5' - 10 3/8"
5
3' - 0"
D
FEC1
2' - 3"
26.009
134
1/4" = 1'-0"
X
EQ
9
6' - 1 3/4"
A-402
Murphy USA
1/4" = 1'-0"
26.009 D
9
AH
G
355
8
Drawn by:
AA
ALIGN
KITCHEN
4
X 16' - 8 1/4"
3' - 0"
7 1/2"
4
ALIGN
A
COPY
G
W
8
25
1' - 9"
Checked by:
Checker
2' - 0"
7
1/4" = 1'-0"
QQ 1' - 3"
3' - 0"
ENLARGED PLAN
5
X
A
REF
STORAGE 133B
9"
PP
7
REF
NN
KITCHEN 134 - N
REF
10
1
ENLARGED PLAN 1/4" = 1'-0"
CD
A-402
12/1/2015 4:19:18 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
GENERAL NOTES ENLARGED PLANS & ELEVATIONS
EQUIPMENT SCHEDULE - BASEMENT EQUIPMENT
ID AA BB CC DD EE FF GG HH II JJ KK LL MM NN OO PP QQ RR SS TT UU VV WW XX YY ZZ AAA BBB CCC DDD EEE FFF GGG HHH JJJ LLL MMM
DESCRIPTION IMAGE PRESS C800 COPIER/PRINTER C700 COPIER/PRINTER LARGE PAPER CUTTER EXTERNAL FOLDING UNIT SMALL LAMINATING MACHINE LARGE LAMINATING MACHINE PAPER JOGGER COVERBIND MACHINE PAPER PALLET BOOK PUNCHES COIL CRIMPER CORNER ROUNDER ELECTRIC STAPLER PADDY WAGON DRILL BINDING MACHINE STEP STOOL ANTI-FATIGUE FLOOR MAT TALL CHAIR FOR WORK TABLE WIRE CART HEAVY DUTY CART SHELVING - HEAVY DUTY SHELVING BOOK CASE LARGE WORK TABLE SMALL TABLE BIG DRINK COOLER FED EX SHIPPING / RECEIVING POSTAGE FED EX MAIL SORTING BINS MAIL SORTING TABLE BULK MAILER BUILDING OPS. MECHANICS WORKSTATION MEETING TABLE COOLER WORK TABLE
DIMENSIONS W 32" 32" 51" 24 1/2" 7 3/4" 19 3/4" 11 1/2" 25" 48" 21" 10 1/2" 5" 6 5/16" 30" 19 1/2" 14" 20" 36" 25" 23" 24" 24" 24" 13" 48" 36" 30" 48" 36" 24" 16" 48" 24" 48" 30" 30" 48"
L 108" 108" 60 1/2" 49" 20 7/8" 42" 15 1/4" 29 1/2" 48" 22 1/2" 14 1/2" 10 1/2" 9 19/32" 30" 31 1/2" 19" 26" 144" 25" 42" 52 1/4" 72" 72" 34 1/2" 96" 96" 78 1/8" 96" 96" 60" 165" 96" 72" 72" 72" 48" 96"
MEP+T REQUIREMENTS
H 56" 56" 52 1/2" 27" 4 1/8" 28 3/4" 15 1/4" 17" 4" 8 1/2" 5 3/4" 5 3/4" 5 5/16" 66 1/2" 59 1/4" 12" 30" 1/8" 47" 38" 41" 84" 72" 72" 36" 36" 78 5/8"
PROVIDED BY OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER
INSTALLED BY
SPEC SECTION
COMMENTS 1. 2.
X
-DENOTES WALL FINISH
KEYNOTES
L
G
G
FURNITURE PROVIDED FOR REFERENCE ONLY - REFER TO I-200 SERIES FOR FURNITURE PLANS REFER TO I-100 SERIES FOR ROOM FINISH SCHEDULE AND FINISH PLANS.
H
J
K
M
N
P
Q
R
S
T
##.###
U
L
8
H
AAA
9
9
STORAGE 010
6
10
RECEIVING
MECH EQUIPMENT ROOM
001
002
10
II
7
11
BBB
11
II
CCC
12
12
ENLARGED PLAN - RECEIVING - 001
4
LL
1/4" = 1'-0"
JJ
JJ
GG KK
MM
NN
XX
CC
OO
ZZ
MAIL ROOM 004
13
13 TT
PRINT ROOM A
B
C
D
E
F
G
DDD
14
FFF
003
ZZ SS
RR
14
SS
MMM
XX RR VV GG EE
PP
UU
15
15 FF
15
BUILDING OPERATIONS/ MECHANICS
Checker
005
YY
YY
EEE
LLL
Murphy USA VV
EEE
16
16
16
DD
HH
Commision #15054.00 200 Peach Street El Dorado, AR 71730
GGG JJJ
BB
AA RR
HHH
HHH
17
17
Checked by:
17
Westlake Reed Leskosky 18
18
VV
18
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
19
ENLARGED PLANS & ELEVATIONS
VV
WW HHH
HHH
19
Author
19
Drawn by:
CD 3
ENLARGED PLAN - 005 & 006 1/4" = 1'-0"
2
ENLARGED PLAN - MAIL ROOM 004 1/4" = 1'-0"
1
ENLARGED PLAN - PRINT ROOM-003 1/4" = 1'-0"
A-403
02 SECOND FLOOR 13' - 4"
A-561
2
NEW GYP SOFFIT ABOVE MODULAR WALL
2
OPEN TO BEYOND
9' - 0"
12/1/2015 4:20:01 PM
7
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
2
WALL MOUNTED INTERACTIVE DISPLAY SEE AUDIO/VISUAL
OPEN TO BEYOND
SEMI-RECESSED FEC
KEYNOTES 05.014 EQ
EQ
05.032
EQ
08.003 08.017 09.006
10.003
EXISTING FIRE ALARM HORN
13
OUTSIDE CONFERENCE 132 - N
12
1/4" = 1'-0"
CUSTOMER EXPERIENCE - E 1/4" = 1'-0"
10.003 22.003 23.002 27.001 E.010
E.010
EXISTING TACKBOARD W/ GLASS DOOR
EXISTING HOSE CABINET
E.022 E.023
2
09.006
11
2
2
2
EXISTING RECESSED FIRE EXSTINGUISHER CABINET
22.003
2
2
2
2
5 EQ. SPACES
MODULAR WALL PANEL
3 EQ. SPACES
GLASS TYPES NOTE: TYPES BELOW ARE INDICATED FOR CONVIENENCE. SEE TECHNICAL SPECIFICATION SECTION 088000 FOR GLASS TYPE DESCRIPTIONS.
1/4" = 1'-0" 9
E.022
23.002
23.002
23.002
A-561
05.014
23.002
23.002
1
3/8" CLEAR, FULLY TEMPERED GLASS
2
9/16" CLEAR, LAMINATED GLASS
3
1/2" CLEAR, FULLY TEMPERED - LOW IRON
4
9/16" CLEAR, LAMINATED GLASS - LOW IRON
5
CLEAR, FIRE-RATED SAFETY GLASS
6
5/8" LAMINATED SAFETY GLASS, SELF CLEANING COATING ON TOP SURFACE, 80% LIGHT TRANSMISSION PVB INTERLAYER
7
10-5/16" LOW IRON, TEMPERED CHANNEL GLASS SYSTEM (DOUBLE GLAZED IN CURVED TRACK)
8
1" CLEAR, TEMPERED INSULATED GLASS UNIT (IGU)
T
TEMPERED (SEE ELEVATIONS FOR LOCATIONS)
E.022
13 9 7
A-562
A-441
3
3
EQ
9
3
EQ
EQ
3
EQ
3
3
EQ
3
EQ
EQ
3
EQ
E.022
BREAK-OUT 133 - N
8
1/4" = 1'-0"
E.022
05.032
GLASS NOTES: 1.
ENCLOSED PATIO - S
2.
1/4" = 1'-0" 3.
E.023
08.003
E.023
05.014
E.022
4. 5. 6.
OPEN TO BEYOND
CENTER DOOR CONTROL ON PANEL (TYP.) SEE A-401 FOR MOUNTING HEIGHT
7
LOBBY - S
6
1/4" = 1'-0"
LOBBY - E
5
1/4" = 1'-0"
ULTRA-QUICK DRYING TYPE SEALANT MUST BE USED FOR ALL GLASS LAMINATE LOCATIONS. ALL SEALANTS AT BUTTGLAZED JOINTS TO BE TRANSLUCENT COLOR U.O.N. ALL GLASS IN DOORS, ADJACENT TO DOORS AND WITHIN 18" FROM FLOOR MUST BE SAFETY GLASS (TEMPERED OR LAMINATED). ALL GLASS OVERHEAD MUST BE SAFETY GLASS (LAMINATED TYPE ONLY). ALL EXTERIOR INSULATED GLAZING MUST MEET OR EXCEED LOCAL AND FEDERAL ENERGY CODES. SHOP DRAWINGS ARE REQUIRED FOR ALL GLAZING AND ALL SIZES TO BE VERIFIED BASED ON FIELD CONDITIONS U.O.N.
3
OPEN TO BEYOND 2' - 6"
MURPHY USA STORE N.I.C
1
3
3
EQ
EQ
08.017
1' - 0"
1
LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD STEEL COLUMN WITH 1 HR. INTUMESCENT COATING - SEE STRUC. REVOLVING DOOR FROSTED PRIVACY FILM APPLIED TO GLASS METAL INFILL PANEL FOR ADA DRINKING FOUNTAIN. MATCH EXISTING CONSTRUCTION, EXISTING PANELS TO BE REFINISHED FIRE EXSTINGUISER SIGN DOUBLE SIDED DRINKING FOUNTAIN, SEE PLUMBING SUPPLY AIR JET NOZZLE - SEE MECHANICAL WALL MOUNTED MONITOR - SEE AV METAL PANELS TO BE REFINISHED - PAINT TO MATCH GLAZED PARTITION ALUMINUM FRAMES EXISTING STONE PANEL CLADDING TO REMAIN SALVAGE STONE PANEL CLADDING. REINSTALL IN NEW LOCATION.
2
CUSTOMER EXPERIENCE - S
10
1/2" = 1'-0"
##.###
SEE SHEET A-531 FOR RECEPTION DESK
LOBBY - W 1/4" = 1'-0"
E.023
4
2
2
2
2
2
2
2
2
2
2
2
2
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
CORRIDOR 159 - S 1/4" = 1'-0"
3
3
3
3
3
3
3
3
3
3
3
3
3
11 EQ. SPACES
3
CORRIDOR 159 - N
Murphy USA
1/4" = 1'-0"
FIRST FLOOR INTERIOR ELEVATIONS Checker
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Checked by:
Westlake Reed Leskosky 2
2
2
2
2
2
EQ
EQ
EQ
EQ
EQ
EQ
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
INTERIOR ELEVATIONS
Drawn by:
AH
2
SECOND FLOOR INTERIOR ELEVATIONS
OUTSIDE CONFERENCE 247 - E 1/4" = 1'-0"
1
OUTSIDE CONFERENCE 229 - W 1/4" = 1'-0"
CD
A-411
12/1/2015 4:20:33 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
KEYNOTES 5"
09.023 12.010 27.001 D.038
9' - 0"
E.026 2
2
EQ
17
2
2
2
EQ
EQ
EQ
EQ
OUTSIDE ENGINEERING CONFERENCE 317 - N
16
1/4" = 1'-0"
TEAMING - TYP.
OUTSIDE CONFERENCE 467_S
15
1/4" = 1'-0"
GLASS TYPES
1/4" = 1'-0"
NOTE: TYPES BELOW ARE INDICATED FOR CONVIENENCE. SEE TECHNICAL SPECIFICATION SECTION 088000 FOR GLASS TYPE DESCRIPTIONS.
ALUMINUM CORNER CAP TRANSITION BETWEEN GLAZING AND DOOR TO BE ALL PART OF ONE SYSTEM / MANUFACTURER
1
1
EQ
14
2
EQ
2
EQ
OUTSIDE GUEST OFFICE 326 - W
13
1/4" = 1'-0"
2
EQ
2
EQ
2
EQ
OUTSIDE CONFERENCE 329 - W
12
1/4" = 1'-0"
1
3/8" CLEAR, FULLY TEMPERED GLASS
2
9/16" CLEAR, LAMINATED GLASS
3
1/2" CLEAR, FULLY TEMPERED - LOW IRON
4
9/16" CLEAR, LAMINATED GLASS - LOW IRON
5
CLEAR, FIRE-RATED SAFETY GLASS
6
5/8" LAMINATED SAFETY GLASS, SELF CLEANING COATING ON TOP SURFACE, 80% LIGHT TRANSMISSION PVB INTERLAYER
7
10-5/16" LOW IRON, TEMPERED CHANNEL GLASS SYSTEM (DOUBLE GLAZED IN CURVED TRACK)
8
1" CLEAR, TEMPERED INSULATED GLASS UNIT (IGU)
T
TEMPERED (SEE ELEVATIONS FOR LOCATIONS)
2
EQ
EQ
THIRD FLOOR 325 CONFERENCE - W
GLASS NOTES:
1/4" = 1'-0"
1. 2. 3.
THIRD FLOOR INTERIOR ELEVATIONS
4. 5.
11
4
4
EQ
EQ
EQ
3
3
3
3
3
3
3
3
3
3
8' - 11 1/2" VIF
6.
4
3
11 EQ. SPACES
OUTSIDE CONFERENCE 463 - N
10
1/4" = 1'-0"
CERAMIC TILE - SEE FINISH SCHEDULE REPLACE EXISTING MARBLE COUNTERTOPS WITH NEW MARBLE COUNTERTOPS WALL MOUNTED MONITOR - SEE AV REMOVE WOOD VENEER ON SOFFIT. PATCH WITH GWB AND PAINT TO MATCH EXISTING MILLWORK TO REMAIN
10 A-533
2
EQ
##.###
CORRIDOR 400 - N
4
EQ
EQ
4
4
4
EQ.
EQ.
EXECUTIVE - S
9
1/4" = 1'-0"
4
ULTRA-QUICK DRYING TYPE SEALANT MUST BE USED FOR ALL GLASS LAMINATE LOCATIONS. ALL SEALANTS AT BUTTGLAZED JOINTS TO BE TRANSLUCENT COLOR U.O.N. ALL GLASS IN DOORS, ADJACENT TO DOORS AND WITHIN 18" FROM FLOOR MUST BE SAFETY GLASS (TEMPERED OR LAMINATED). ALL GLASS OVERHEAD MUST BE SAFETY GLASS (LAMINATED TYPE ONLY). ALL EXTERIOR INSULATED GLAZING MUST MEET OR EXCEED LOCAL AND FEDERAL ENERGY CODES. SHOP DRAWINGS ARE REQUIRED FOR ALL GLAZING AND ALL SIZES TO BE VERIFIED BASED ON FIELD CONDITIONS U.O.N.
1/4" = 1'-0"
PAINT TO MATCH ADJACENT GWB SOFFIT
D.038 09.023
2
2
3
3
3
3
EQ
EQ
EQ
EQ
EQ
EQ
12.010
E.026
8
EXECUTIVE SUITE 462 - W
7
1/4" = 1'-0"
EXPANSION 430 - S
6
1/4" = 1'-0"
3
3
2
2
2
2
EQ
EQ
EQ
EQ
EQ
EQ
EXPANSION 430 - W
5
1/4" = 1'-0"
HSSE 419 - E
4
1/4" = 1'-0"
CONFERENCE 444 1/4" = 1'-0"
Murphy USA 3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2
2
EQ
EQ
EQ
EQ
EQ
EQ
EQ
Checked by:
Checker
3
11 EQ. SPACES
3
Drawn by:
AH
FOURTH FLOOR INTERIOR ELEVATIONS
OUTSIDE AUDITORS 422 -N 1/4" = 1'-0"
2
TREASURY 426 - S 1/4" = 1'-0"
1
OUTSIDE CONFERENCE 421 - W 1/4" = 1'-0"
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
INTERIOR ELEVATIONS
CD
A-412
X
4
AA
2
A-421
05.005
A-421
W
05.005
1' - 0"
1' - 0"
A-421
W
4
X 1' - 10 1/2"
12/1/2015 4:21:33 PM
W
2
UP
X
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
AA
AA
A-421
DN
UP
14
14
14
KEYNOTES
9 A-423
##.###
08.011
05.028
05.005
26.008 E.009
SLOPED
15
15
05.028 08.011 09.012
GWB SLOPED
GWB SLOPED
E.009 PTD.
26.008 E.009
15
STAINLESS STEEL 1 1/2" DIA. HANDRAIL MOUNTED TO GLASS GUARDRAIL STAINLESS STEEL EDGE GLASS GUARDRAIL W/S.S. STANDOFFS NEW TERRAZZO LANDINGS AND TREADS ON EXISTING STAIR CONSTRUCTION LINEAR LED LUMINAIRE EXISTING STRUCTURAL STEEL TO REMAIN
08.011
16
12
3
3
A-421
A-421
16
17
17
10 A-423
10 A-423
A-423
16
17
LINE OF EXISTING STEEL
7
ENLARGED STAIR PLAN 01
6
3/8" = 1'-0"
17
16
15
14
ENLARGED STAIR PLAN 02 3/8" = 1'-0"
W
13
Monumental Stair RCP
5
X
3/8" = 1'-0"
AA
3 A-421
2
4
A-421
A-421
04 FOURTH FLOOR 40' - 0"
13' - 4"
1 A-423
03 THIRD FLOOR 26' - 8"
2
11 A-423
13' - 4"
A-423
2 A-423
09.012 TYP
3 A-423
08.011
02 SECOND FLOOR 13' - 4"
Murphy USA
TYP
Checker
Commision #15054.00 200 Peach Street El Dorado, AR 71730
3' - 6"
13' - 4"by: Checked
Westlake Reed Leskosky E.009
1' - 0"
3' - 0"
A-423
3' - 0"
12
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
ALIGN GLASS JOINT TO EXSITING BOTTOM OF STEEL MITRED EDGE
26.008
9
12
A-423
A-423
01 FIRST FLOOR 0' - 0"
MM Drawn by:
1
3D AXON - MONUMENTAL STAIR
EQ
EQ
EQ
ENLARGED STAIR PLANS & SECTIONS
3' - 7"
CD 4
Monumental Stair Section 3/8" = 1'-0"
3
Monumental Stair Section - Transverse 3/8" = 1'-0"
2
Monumental Stair Elevation 3/8" = 1'-0"
A-421
SECONDARY 12/1/2015 4:21:49 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
KEYNOTES 03.007 03.012 05.002 4
05.016 05.017
A-310
07.007
F
E
D
C
B
05.016 5' - 3"
A
U
T
S
R
Q
22.010 22.011 26.005 26.007 32.001
P
05.017 1' - 3"
1' - 0"
5' - 0"
5' - 0"
5' - 0"
5' - 0"
3' - 0"
05.017
1' - 3"
32.002
05.016 3
5' - 0"
26.007 32.004 32.005 E.009 E.019 E.024
26.007
A-503 32.001
3"
2' - 6"
3' - 0"
3' - 0"
3"
01 FIRST FLOOR 0' - 0"
##.###
COMPACTED GRANULAR BASE NEW CAST IN PLACE CONCRETE RETAINING WALL AND FOUNDATION. SEE STRUCT. STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. STAINLESS STEEL RAILING 2" X 3/4" BAR STOCK 3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH 2" X 3" ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER SEE CIVIL SLOT TRENCH DRAIN - SEE PLUMBING STORM WATER PVC PIPING - SEE PLUMBING UPLIGHT FIXTURE - SEE ELECTRICAL LED STEPLIGHT THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB. GRANITE STEP ON 1/2" SETTING BED GRANITE SLAB ON 1/2" SETTING BED EXISTING STRUCTURAL STEEL TO REMAIN EXISTING CONCRETE RETAINING WALL TO REMAIN. EXISTING FLOOR DRAIN TO REMAIN
1/8" / 1'-0"
E.019
E.019
03.007
8
STAIR EX-1 - SECTION
7
3/8" = 1'-0"
4
A
B
C
D
A-310
7 A-503
1' - 3"
RAMP SECTION 3/8" = 1'-0"
P
E
32.002
Q
R
S 26' - 0"
T
26.005
U
05.017
CC
DD 1 A-503
6" 6"
4' - 0"
1' - 3"
26.005 1 1/2" 1/2"
05.017 -0' - 6"
2"
05.016 E.024 2
1
A-422
A-422
7
05.016
7' - 2"
05.016
EQ
CJ -2' - 6" 3/8" / 1'-0"
0' - 0"
SEE LANDSCAPE DRAWINGS
0.0
3 05.017
1' - 3"
1/8" / 1'-0"
05.016
1 1/2"
A-503
2"
A-422
05.016 CJ 3
10
32.005
A-422 22.010
11
8
05.017
A-503
A-503
EQ
A-422 CJ
32.005
RAMP PLAN
5
3/8" = 1'-0"
1 1/2" 2"
05.016
1/2"
05.002
STAIR EX-2 - PLAN
4
3/8" = 1'-0"
CONCRETE BACKUP WALL 05.017
6
STAIR EX-1 - PLAN 3/8" = 1'-0"
A
B
C
D
4
E
F
G
A-310
N
P
Q
R
S
T
U CC
07.007
1' - 0" (4) EQ. TREADS = 4' - 0" 1' - 2" 05.017
26.007
32.004
1"
Murphy USA
DD
26' - 0" 32.005
22.011
1' - 0" (4) EQ. TREADS 4' - 0"
1' - 2"
1"
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Checker
26.007 26.007 05.017
3' - 0"
A-503
32.001
2' - 2 7/8"
ALIGN NEW SLAB TO EXISTING SLAB
1"
32.002
05.017
2"
03.007 1/8" / 1'-0"
A-503 3"
03.012
3' - 0"
7
1/8" / 1'-0"
3' - 0"
4 1/2"
Checked by:
26.007
1 1/8"
1 26.007
6 A-503 9 A-503
Author Drawn by:
STAIR EX-1 - SECTION 3/8" = 1'-0"
03.007
03.012
8" 1' - 0" 8"
3
E.009 32.002
EXISTING CONCRETE WALL GRIND SURFACE AND PAINT TO MATCH EXISTING
01 FIRST FLOOR 0' - 0"
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
ENLARGED STAIR PLANS & SECTIONS
8" 1' - 0"
2
RAMP SECTION 3/8" = 1'-0"
1
STAIR EX-2 - SECTION 3/8" = 1'-0"
CD
A-422
12/1/2015 4:22:04 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
KEYNOTES 03.005 03.010 05.003 05.004 05.005 05.014 05.024 05.025 05.026 05.027 05.028 06.006 07.003 08.011 09.001 09.012 09.015 09.016 09.017 09.019 10.005 26.008 E.009 E.020 E.021
14 W
X
3
4
A-423
A-421
AA
##.###
RAISED CONCRETE SLAB - SEE STRUC. FULL EPOXY SETTING BED OVER STEEL PAN 1/4" TO 3/8" UNDERNEATH TREAD STAINLESS STEEL RAILING CAP STAINLESS STEEL STRUCTURAL GLASS POINT FITTING STAINLESS STEEL 1 1/2" DIA. HANDRAIL MOUNTED TO GLASS GUARDRAIL LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD STEEL ANGLE - SEE STRUCT. COLD FORM METAL FRAMING NEW STAINLESS STEEL 1 1/2" DIA. HANDRAIL MOUNTED TO EXISTING GLASS GUARDRAIL WELDED STEEL FRAME TO EXISTING HSS STAINLESS STEEL EDGE WOOD BLOCKING - FIRE RETARDANT SILICONE SEALANT GLASS GUARDRAIL W/S.S. STANDOFFS SUSPENDED GYPSUM BOARD CEILING NEW TERRAZZO LANDINGS AND TREADS ON EXISTING STAIR CONSTRUCTION REFINISH EXISTING BASE SHOE WITH STAINLESS STEEL CLADDING NEW TERRAZZO FINISH ON CONCRETE PAD ON SLAB ON GRADE EPOXY TERRAZZO TAPE AND SPACKLE FLANGE IN GYP CEILING 1/2" BLACK EPOXY ABRASIVES STOP 3" FROM BOTH ENDS LINEAR LED LUMINAIRE EXISTING STRUCTURAL STEEL TO REMAIN EXISTING GLASS GUARDRAIL TO REMAIN EXISTING STEEL PAN STAIR
2" 05.004
26.008
09.016 1/4"
1/2"
1/2"
10.005
E.009 ALIGN
03.005
1/2"
E.021
3"
3 1/2"
03.010
WELD TO EXISTING STRUCTURAL STEEL
PAINT RISERS TYP.
STAIR DETAIL - PLATFORM
17
DETAIL - STAIR TREAD
11
3" = 1'-0"
2"
E.009
09.017
01 FIRST FLOOR 0' - 0"
12
8 A-423
ALIGN
1" "
6 5/8"
05.028
0 3/8
1/2"
R 0' -
3" = 1'-0"
W
E.009 2"
08.011
1/4"
07.003 05.028
1/2" TEMPERED GLASS
10
17
PLAN DETAIL - 01 LANDING 1 1/2" = 1'-0"
MITRED CORNERS 09.012
W
01 FIRST FLOOR 0' - 0"
9
STAIR DETAIL - BASE SHOE @ GROUND LEVEL 3" = 1'-0"
8
STAIR LANDING DETAIL 5
1 5/16"
4 A-423
W
X
05.024
3" = 1'-0"
17
1 3/4" 1"
05.014
1 1/2"
1 1/2" 05.003 07.003
05.005
E.020
WELD STEEL ANGLE TO EXISTING STRUCTURAL STEEL 1 1/2"
3' - 9 3/8"
05.026
3"
26.008
3' - 0"
09.001 05.014
08.011
MITRED CORNER 05.014
5' - 5 3/8"
MITRED CORNER 08.011
STAIR LANDING DETAIL 3 3" = 1'-0" 5 A-423
17 17
09.012
09.015
3"
3" = 1'-0"
6
3"
STAIR LANDING DETAIL 4
Murphy USA 05.028
ALIGN
7
05.004 05.025 05.024
E.009
05.014
09.001 1 5/16"
09.012
Westlake Reed Leskosky
26.008
05.028
09.019
05.027
2"
1/8"
05.014
E.009
E.021
09.019 6 A-423
Commision #15054.00 200 Peach Street El Dorado, AR 71730
1' - 3"
Checked by:
Checker
06.006
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
26.008
7 A-423
ALIGN
STAIR DETAILS
ALIGN
Drawn by:
Author
2 1/2"
5
STAIR LANDING DETAIL 2 3" = 1'-0"
4
STAIR LANDING DETAIL 1 3" = 1'-0"
3
STAIR DETAIL - LANDING 01 1 1/2" = 1'-0"
2
STAIR DETAIL - STRINGER 1 1/2" = 1'-0"
1
Stair Detail - Landing Glass Guardrail 1 1/2" = 1'-0"
CD
A-423
SECONDARY Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
12/1/2015 4:22:37 PM
N N
P
Q
R
S
P
T
Q
R
S
MOCKUP: FULL-HEIGHT OF OVAL CONF. WALL AT THIS LEVEL WITH OUTER AND INNER PORTIONS SHOWN IN ANNOTATION BUBBLE. (SEE 2/A-432 FOR MORE INFO.)
18
EXISTING W33 BEAM BEYOND
T
ALIGN - LOWER COVE PORTION ONLY AT SECOND FLOOR CEILING
10
18
GENERAL NOTES ENLARGED PLANS & ELEVATIONS
STEEL COL. W/ 2-HR. INTUMESCENT COATING
A-561
1.
05.011
2.
CENTERLINE OF CURTAIN TRACK
19
19
X
F13 ADJUSTABLE DOWNLIGHT
08.009
20
KEYNOTES
1" CONT. OFFSET SLOT DIFFUSER 4" PLENUM DASHED-IN ABOVE 05.011 CEILING SPEAKER SEE AV.
20
06.003
ALIGN
4' - 5"
17' - 6"
2
##.###
STEEL COLUMN WITH 2 HR. INTUMESCENT COATING - SEE STRUC. ARCHITECTURAL GRADE VENEER 1/2" PLYWOOD - SEE FINISH PLANS SOLID WOOD FRAME/MOULDING 10-5/16" DOUBLE GLAZED, LOW IRON, TEMPERED CHANNEL GLASS SYSTEM W/ CURVED TRACKS 1/2" TEMPERED, LOW-IRON GLASS PROJECTOR - SEE AV PROJECTOR SCREEN - SEE AV
4 A-432
25' - 5 1/4"
1
08.010 27.005 27.006
1 A-561
A-431
06.005 08.009
MOUNT PROJECT POLE AT CENTER OF ELLIPSE
ELLIPTICAL COLUMN GRID WIDTH - SEE STRUC.
-DENOTES WALL FINISH
CONCEALED SPRINKLER HEAD (EXTENDED COVERAGE)
TYP.
2' - 10"
12'-8 5/8"
CURTAIN TRACK TO SHIFT 3" OUTWARD TO COMPENSATE FOR CURTAIN COMPACTION WITHIN POCKET
FURNITURE PROVIDED FOR REFERENCE ONLY - REFER TO I-200 SERIES FOR FURNITURE PLANS REFER TO I-100 SERIES FOR ROOM FINISH SCHEDULE AND FINISH PLANS.
5
ELLIPSE CENTER: AT GRID INTERSECTION
STARTING POINT: CENTER CHANNEL GLASS ON AXIS
11
21
21
A-561
A-432 A-431
4
4' - 5"
2
3
22
12'-8 5/8"
22
6 A-511
2 A-561
4' - 0"
7
23
24
24
4' - 0"
OVAL CONFERENCE 211
6
3/8" = 1'-0"
Q
5
23
R
19
4
3/8" = 1'-0"
20
21
22
23
Murphy USA
OVAL CONF. 211 - E 3/8" = 1'-0"
Q
23
Checker
R
3/8" = 1'-0"
S
OVAL CONF. 211 - N S
OVAL CONFERENCE 211 - RCP
22
21
20
19
Commision #15054.00 200 Peach Street El Dorado, AR 71730 4
EQ
EQ
HAIRLINE JOINTS U.O.N.
A-511
Checked by:
Westlake Reed Leskosky 06.005
27.005 27.006 06.005
06.003
05.011 08.010 LIGHTING CONTROLS CENTER ON PANEL 06.003
ENLARGED PLANS & ELEVATIONS - OVAL CONF.
Drawn by:
AH
08.009
WOOD BASE TO ALIGN WITH CHANNEL GLASS BASE
3
OVAL CONF. 211 - S 3/8" = 1'-0"
2
OVAL CONF. 211 - W 3/8" = 1'-0"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
1
2
1
A-511
A-511
OVAL ENTRY - TYP. 3/8" = 1'-0"
CD
A-431
12/1/2015 4:22:57 PM
SECONDARY N
P
Q
R
S
T
2' - 0 1/2"
U
LOCATION AND SIZE OF TRACK ANCHORS TO BE VERIFIED ON SHOP DWGS.
CENTER OF TRACK 2' - 0"
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
EDGE OF SLAB
FALL PROTECTION ANCHORS SEE STRUC.
08.009 +/- 6" 3
3"
+/- 10 1/2"
4 1/2" 03.002
05 PENTHOUSE FLOOR 54' - 8 1/2" ROOF 54' - 0" T.O. CONF. ROOF 53' - 4"
A-432
06.007 05.012 05.013 PAINT BTM. TO MATCH CEILING
GENERAL NOTES ENLARGED PLANS & ELEVATIONS
26.006
1.
07.003
2.
05.020 L2"X2" CURVED TO MATCH TRACK
X
09.004 JUTE WEBBING AND FABRIC TO COVER CARRIER. CLIP SEWN TO 1" WEB STRAP. WHIP STICH AT BTM. HEM
MINIMIZE
05.001
MAXIMIZE 09.008
05.011 05.012 05.013 05.020 06.003 06.005 06.006 06.007 07.003 08.009
05.011 OVAL CONF. STRUC: CONCRETE/MTL DECK ON STEEL FRAMING AND COLUMNS (2HR. PROTECTED) SEE STRUC.
09.001 23.001 OFFSET, CURVED TYPE FLANGE 09.002 SEE SPEC APPENDIX FOR BASIS-OF-DESIGN ACOUSTIC PLASTER DETAILS
1 A-432
04 FOURTH FLOOR 40' - 0"
4 A-432
-DENOTES WALL FINISH
KEYNOTES 03.002
05.001
FURNITURE PROVIDED FOR REFERENCE ONLY - REFER TO I-200 SERIES FOR FURNITURE PLANS REFER TO I-100 SERIES FOR ROOM FINISH SCHEDULE AND FINISH PLANS.
08.011 09.001 09.002 09.004
09.008 23.001 26.006
##.###
CONCRETE ON METAL DECK - 2 HR. RATED (NO FIREPROOFING REQD.) - SEE STRUC. STEEL BEAM W/2 HR. SPRAY-ON FIREPROOFING - SEE STRUC. STEEL COLUMN WITH 2 HR. INTUMESCENT COATING - SEE STRUC. 8" AESS CURVED CHANNEL CONT. CURVED BENT PLATE - SEE STRUC. CONT. ALUM. ANGLE - TYPE 6063 ARCHITECTURAL GRADE VENEER 1/2" PLYWOOD - SEE FINISH PLANS SOLID WOOD FRAME/MOULDING WOOD BLOCKING - FIRE RETARDANT WOOD SHIM - SURFACES TO BE PLUM AND LEVEL SILICONE SEALANT 10-5/16" DOUBLE GLAZED, LOW IRON, TEMPERED CHANNEL GLASS SYSTEM W/ CURVED TRACKS GLASS GUARDRAIL W/S.S. STANDOFFS SUSPENDED GYPSUM BOARD CEILING ACOUSTIC PLASTER CEILING CURVED CURTAIN TRACK. DOUBLE LAYERED CURTAIN WHITE BACKING FACING CHANNEL GLASS. SEE SPECS FOR MORE INFO. CURVED 1/4" GWB SOFFIT ON LIGHT GA. FRAMING SUPPLY AIR SLOT DIFFUSER - SEE MECHANICAL CONTINUOUS LINEAR CONCEALED COLOR LED COVE LIGHTING. SEE ELECTRICAL
SECTION DETAIL AT OVAL CONF.
4
1 1/2" = 1'-0"
GRAY TONE DENOTES EXISTING STRUC.
OVAL ENTRY MILLWORK
22
5/8" GWB BOTH SIDES OF 3-5/8" STUDS AT 24" O.C. W/3-1/2" SOUND BATTS TO MAINTAIN ACOUSTIC BARRIER AT EACH FLOOR. SEAL ALL GAPS AND PENETRATIONS
8 1/2" 8"
ROOF 54' - 0"
T.O. CONF. ROOF 53' - 4"
9"
4"
8 1/4"
7"
ALIGN
C.L. OF BEAMS INSIDE OVAL ENTRY
08.011
C.L. OF COL. INSIDE OVAL ENTRY
03 THIRD FLOOR 26' - 8"
1' - 4"
4"
05 PENTHOUSE FLOOR 54' - 8 1/2"
06.005 06.003 03.002
06.007 06.006 05.001
11 A-561
2"
1' - 2" 1' - 4"
SECTION AT OVAL ENTRY ROOF 1 1/2" = 1'-0"
Checker
22
02 SECOND FLOOR 13' - 4"
7"
08.011
NOTE: THIRD FLOOR CONDITION SIMILAR
Checked by:
06.006
04 FOURTH FLOOR 40' - 0"
03.002
06.007 2"
1' - 2" 1' - 4"
BM Drawn by:
1
1/2" = 1'-0"
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
SECTIONS & DETAILS OVAL CONF.
05.001
SECTION at OVAL CONF.
Commision #15054.00 200 Peach Street El Dorado, AR 71730
9"
06.003
2
Murphy USA
C.L. OF BEAMS INSIDE OVAL ENTRY
C.L. OF COL. INSIDE OVAL ENTRY
3
SECTION AT OVAL ENTRY 4TH FLR. 1 1/2" = 1'-0"
CD
A-432
PRIMARY 12/1/2015 4:23:16 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
KEYNOTES 05.006 05.010 05.014 05.015 06.002 06.006 14.001 E.001 E.011
##.###
REPLACE EXISTING GLAZING STANDOFFS WITH STAINLESS STEEL STANDOFFS MISC. STEEL L-BRACING LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD CUSTOM STEEL CLEAT PANEL ATTACHMENT STRUCTURAL GRADE PLYWOOD SHEATHING. WOOD BLOCKING - FIRE RETARDANT NEW STAINLESS STEEL ELEVATOR DOORS EXISTING PASSENGER ELEVATOR TO REMAIN EXISTING LIGHT GA. FRAMING TO REMAIN
GENERAL STEEL PANEL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
BACKING BASED ON 3/4" FIRE RETARDANT PLYWOOD. ALL PANELS TO BE FULLY LAMINATED TO PREVENT OILCANNING. ALL PANELS TO BE MECHANICALLY FASTENED AT TOP A MINIMUM OF 3 TIMES EQUALLY SPACED. STEEL FINISH IS CUSTOM AND MUST GO THROUGH A HOT OXIDATION PROCESS BEFORE LAMINATION. STEEL THICKNESS TO BE A MIN. OF 20 GA. STEEL MUST WRAP EDGES, NO SEAMS ALLOWED. CLEAT ATTACHMENTS CAN BE AN APPROVED PROPRIETARY SYSTEM MADE FOR SIMILAR TYPE OF INTERIOR PANELS. ALL PANELS TO HAVE A CLEAR COAT SEALER. ALL FASTENERS MUST BE CONCEALED ALL FASTENERS INTO EXISTING SURFACE MUST BE SECURED TO PARTITION FRAMING. SCREWS ONLY IN CONTACT WITH EXISTING GWB/CEMENT BOARD ARE NOT ACCEPTABLE. ALL WOOD BLOCKING/FURRING TO BE FIRE RETARDANT.
6" 3"
HAIRLINE MITER JOINTS AT CORNERS TYP.
ALIGN
BLACK OXIDE STEEL LAMINATE DIRECTLY TO EXISTING HEAD AND JAMB
3"
EXISTING GLASS PANEL IN FRONT OF ELEVATORS
FURR-OUT TIGHT AGAINST EXISTING ELEVATOR JAMB ALIGN
05.006 BLACK OXIDE STEEL COVER PLATE
NOTE: CONT. REVERSE BEVEL EDGE AT OPENING
11
STEEL PANEL CORNER DETAIL
10
3" = 1'-0"
STEEL PANEL AT ELEVATOR GLAZING
SEALANT NOT REQUIRED
EXISTING ELEVATOR LANTERN
STEEL PANEL AT ELEV. LIGHT
9
3" = 1'-0"
CEILING - SEE RCP
8
3" = 1'-0"
HAIRLINE JOINT AT TRANSOM TO ALIGN W/JAMB AS SHOWN ON ELEVATION
STEEL PANEL AT GLASS
7
3" = 1'-0"
EXISTING ATRIUM CEILING COFFER BEYOND
BLACK ANODIZED COVER PLATE
STEEL PANEL JOINT 3" = 1'-0"
6
3/4"
3/4"
EXISTING ELEVATOR DOOR JAMB
ALIGN PANEL JOINT AND GLASS CENTERS
A-441 (3) FLAT HEAD WOOD SCREWS MIN. AT TOP OF EACH PANEL EQUALLY SPACED
NOTE: SEE DETAIL 4 FOR MORE INFO.
7
CONCEALED CLEAT TYPE WALL ATTACHMENT
6
A-441
A-615
LIGHT GA. BLACK OXIDE STEEL W/CLEAR SEALER
4' - 6"
3/4" PLYWOOD BACKING 05.014
6
STEEL PANEL AT CEILING
05.014
3" = 1'-0"
3' - 1"
IF WOOD BLOCKING/FURRING USED IT MUST BE FIRE RETARDANT HAIRLINE JOINT
NOTE: SEE DETAIL 4 FOR MORE INFO.
EXISTING ELEVATOR WALL SURFACE - ALL FURRING/CLEATS MUST BE SECURLY FASTENED TO EXISTING METAL FRAMING
5
2"
14.001
BLACK ANODIZED ALUM. COVER BASE PLATE
3
14.001
A-441
LOBBY - N 3/8" = 1'-0"
BLACK ANODIZED ALUM. COVER PLATE - TYP.
U
STEEL PANEL BASE DETAIL
3/4"
5
3" = 1'-0"
V
W
X
AA
BB
CC
DD
EE
Murphy USA
PAINT ALL EXPOSED SURFACES FLAT BLACK REVERSE BEVEL EDGES AT ALL EXPOSED JOINTS U.N.O.
Checked by:
Checker
E.001
E.001 11 A-441
4
Commision #15054.00 200 Peach Street El Dorado, AR 71730
10 A-441
8 A-441
STEEL PANELS FACING ATRIUM 3" = 1'-0"
G3
25
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
NOTE: SEE DETAIL 4 FOR MORE INFO.
26 STEEL FINISH TO WRAP BACK OF PANEL AT REVEAL
Author Drawn by:
Westlake Reed Leskosky
14.001
05.014
05.014
9 A-441
14.001
ENLARGED ELEVATOR PLANS & ELEVATIONS
CONT. 3/8" REVEAL BTWN. CEILING AND PANEL
CD 2
STEEL PANEL AT ATRIUM SOFFIT 3" = 1'-0"
1
01 FIRST FLOOR - ELARGED ELAVATOR PLAN 3/8" = 1'-0"
A-441
12/1/2015 4:23:28 PM
4
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
3.9 1' - 0"
0.0
08.008 08.018
4"
07.003
6" 1"
4"
4"
07.014
08.008
NOTCH ALUMINUM RAFTER TO ALLOW INTERNAL WEEPAGE CHANNEL TO DRAIN INTO GUTTER
08.006 1"
1"
6" NOTCH ALUMINUM RAFTER TO ALLOW INTERNAL WEEPAGE CHANNEL TO DRAIN INTO GUTTER. 05.020
08.006 ALUMINUM SHIM AS REQD. 05.020
05.020
3"
08.008 08.006
1 7/8"
07.015 4"
General Notes 1. 2.
GUTTER SLOPE .5% OVER 30'-0"
NOTCH ALUMINUM RAFTER. CAP ENDS W/ .050 ALUMINUM CLOSURE
08.006
07.008
KEYNOTES
07.008 07.015
05.040
GUTTER LOW POINT STEEL STIFFENER PLATES 5'-0" O.C. SEE STRUCTURAL.
05.019
07.007
10 7/8"
BEAM BEYOND
05.017 05.018
8"
05.019
STRUCTURAL STEEL BEYOND
05.019 05.019
05.018
05.019
05.020 05.025 05.031 05.036 05.038 05.039 05.040 05.043 06.008 07.003 07.007
26.008
11
07.008 07.009 07.010 07.014 07.015
SECTION DETAIL
10
3" = 1'-0"
SECTION DETAIL
SECTION DETAIL
9
3" = 1'-0"
8
3" = 1'-0"
SECTION DETAIL
7
3" = 1'-0"
SECTION DETAIL 3" = 1'-0"
0.0
5"
5" 08.008
EAF910
EAF910
3"
3"
2 1/2"
05.039 NOTCHED AT ENDS
07.022 07.023 07.024 07.025 08.004 08.006 08.008 08.018
08.008
08.006
08.006
05.018
08.019 09.011 12.001 22.011 26.005 26.008 32.001 E.028
##.###
3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH AESS TUBE SECTION W/ HIGH PERFORMANCE COATING. SEE STRUCTURAL. CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING CONT. ALUM. ANGLE - TYPE 6063 COLD FORM METAL FRAMING STAINLESS STEEL Z CLIP ASSEMBLY SHIM AS REQUIRED STEEL BEAM W/1 HR. SPRAY-ON FIREPROOFING - SEE STRUC. CONT. STAINLESS STEEL ANGLE WITH SLOTTED CONNECTION .050 ALUMINUM CLOSURE PLATE HSS 6"X4"X1/4" - SEE STRUC. STEEL BASE PLATE - SEE STRUCTURAL 1/2" EXTERIOR GRADE PLYWOOD SILICONE SEALANT 2" X 3" ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER SEE CIVIL ZINC BOX GUTTER SEALANT W/ BACKER ROD PERMEABLE WEATHER RESISTIVE BARRIER METAL GUTTER STAY ATTACHED AT RAFTER AND MIDSPAN RUBBER MEMBRANE BETWEEN ALUMINUM RAFTER AND STEEL ZINC FLASHING DRIP EDGE TERMINATION BAR ZINC FLASHING STEEL STIFFENER SSG ALUMINUM CURTAIN WALL SYSTEM SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED GLASS TYPE 6. SEE GLASS TYPE LEGEND ALUMINUM CLOSURE CHANNEL ADHERED TO LAMINATED GLASS 1" INSULATED GLASS UNIT (IGU) - SEE ELEVATIONS FINISH CEILING - SEE RCP & FINISH SCHEDULE MANUAL ROLLER SHADE STORM WATER PVC PIPING - SEE PLUMBING UPLIGHT FIXTURE - SEE ELECTRICAL LINEAR LED LUMINAIRE THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. EXISTING STUCCO SOFFIT TO REMAIN. PATCH AS REQD.
#4
#4
1' - 4"
SEE SHEET A-106 FOR ALTERNATE #2. SEE STRUCTURAL DRAWINGS FOR STEEL CANOPY GEOMETRY.
08.008 3"
GUTTER SLOPE 1% OVER 30'-0"
3 3/4"
07.015
'-0" 1 3/4" / 1
07.014
08.006 05.036
08.018
05.019
05.019
05.019
1' - 0"
07.015
1' - 0"
07.015
1/4" 1 1/2"
07.007 26.005 05.038
06.008
6
TYP GLASS SUPPORT FRAME 3" = 1'-0"
5
TYP GLASS SUPPORT END 3" = 1'-0"
05.031
1
05.025 BRACING AS REQ'D 05.017
06.008 7"
0.8
07.010 07.023 07.024
05.025
07.025 E.028 09.011
2' - 8"
02 SECOND FLOOR 13' - 4"
3' - 8"
3/4" MIN
12.001
07.009 08.004
GUTTER SLOPE .5% OVER 45'-0"
2 3/4"
08.019
07.008 05.039
4
Murphy USA
CURTAIN WALL - HEAD 3" = 1'-0"
22.011
Checker
1 05.031
INSULATING GLASS SEE ELEVATIONS FOR TYPE
05.043
05.019
Checked by:
07.022
01 FIRST FLOOR 0' - 0"
5/8" GWB
ALUMINUM GLAZING CURTAINWALL SYSTEM SEALANT W/ BACKER ROD MAINTAIN UNOBSTRUCTED WEEP OUTLET
FINISH FLOOR - SEE FINISH PLANS
REPLACE BLOCKING AS REQD.
6" 05.036
01 FIRST FLOOR 0' - 0"
1
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
EXTERIOR DETAILS
3" = 1'-0"
26.008
MM Drawn by:
CURTAINWALL SILL
Westlake Reed Leskosky
REPAIR FLASHING AS REQD.
SCHEDULED WALL BASE 32.001
Commision #15054.00 200 Peach Street El Dorado, AR 71730
CD 3
SECTION DETAIL 3" = 1'-0"
2
SECTION DETAIL 3" = 1'-0"
A-501
12/1/2015 4:23:44 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
0.0
07.026 07.027 07.028 E.022 7"
07.029
0.8
07.030 COLUMN CENTERLINE
05.045 07.025
5" 07.025
07.009
3/4"
07.023
07.022
06.006
07.022
" -3
General Notes
07.014
1. 2.
07.027
07.034
3/4"
07.029 07.030
07.036
05.020
02 SECOND FLOOR 13' - 4"
07.006
KEYNOTES
05.019 NOTCH ALUMINUM RAFTER GUTTER HIGH POINT .5 % SLOPE
2 3/16"
07.035
07.028 3"
07.021 WRAP COLUMN BEYOND
03.001 03.007 03.012 SEE SECTION DETAIL 9 / A-502
05.014 05.017
05.032 05.018
07.032
05.019
05.046 SEE PLAN DETAIL
06.008
REPAIR SPRAYED ON FIREPROOFING AS REQD.
2 / A-502
05.020 05.025 05.031 05.032
07.016 06.006
05.035
05.018 05.036
05.033 05.034 05.035 05.036 05.045
07.006
07.022 2" 6"
SECTION DETAIL
07.021
3" = 1'-0"
1/8" / 1'-0"
07.026
1' - 3"
07.027
1 1/2"
05.046 06.006 06.008 07.004 07.005 07.006 07.009 07.010 07.012 07.014 07.016
05.035 07.017
07.028
1' - 1 1/2"
07.029
2"
10
07.024
09.001
08.004
07.025
07.030
STEEL BEYOND W 1 HR SPRAY ON FIREPROOFING
07.021
09.024 08.019
4"
05.035 6" 08.008 1 1/2"
08.006
3/4"
06.006
9
1"
5"
07.017 07.018 07.019 07.020 07.021 07.022 07.023 07.024 07.025 07.026 07.027
SECTION DETAIL 3" = 1'-0"
8
0.0 05.020
05.032
07.009
08.019
EXTERIOR MOCK UP EXTENTS FF
07.012 08.004
05.034
07.009
1/4" 3/4"
3"
05.036
09.023
1' - 1"
01 FIRST FLOOR 0' - 0"
09.025
07.028 07.029
08.004 05.017
1/4"
08.019
07.030 07.032 07.033 07.034 07.035 07.036 07.037 08.004 08.006
07.022 07.021
GROUT SOLID
05.031
07.009 5"
6"
SEE SHEET A-106 FOR ALTERNATE #2. SEE STRUCTURAL DRAWINGS FOR STEEL CANOPY GEOMETRY.
07.028
06.006
GUTTER HIGH POINT .5% GUTTER SLOPE OVER 35'
1'
08.006
07.026
07.033
7 1/4"
08.008
2 3/4"
2 1/2"
" -3
1'
4"
CUSTOM IGU EDGE. REINFORCE WITH EMBEDDED STEEL AS REQD.
8"
1"
07.017 07.010
05.025 07.016
1' - 6"
2' - 3"
3"
03.012
06.008
26.007
08.019
0.0
05.033 05.032 1' - 4 1/2"
07.021
06.006
08.008 08.019 09.001 09.023 09.024 09.025 26.007 32.002 E.022
##.###
NEW SLAB ON GRADE. - SEE STRUCTURAL COMPACTED GRANULAR BASE NEW CAST IN PLACE CONCRETE RETAINING WALL AND FOUNDATION. SEE STRUCT. LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD 3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH AESS TUBE SECTION W/ HIGH PERFORMANCE COATING. SEE STRUCTURAL. CUSTOM BUILT UP SECTION, WELDED, TAPERED AESS W/ HIGH PERFORMANCE COATING CONT. ALUM. ANGLE - TYPE 6063 COLD FORM METAL FRAMING STAINLESS STEEL Z CLIP ASSEMBLY SHIM AS REQUIRED STEEL COLUMN WITH 1 HR. INTUMESCENT COATING - SEE STRUC. L 4"X6" CONTINUOUS - SEE STRUC. HSS 4"X4"X1/4" - SEE STRUCT. CONTINUOUS BENT PLATE - SEE STRUC. STEEL BEAM W/1 HR. SPRAY-ON FIREPROOFING - SEE STRUC. 1 1/2" METAL ROOF DECK W/ 1 HR. SPRAY-ON FIRE PROOFING SEE STRUC. STEEL BEAM W/1 HR. INTUMESCENT COATING - SEE STRUC. WOOD BLOCKING - FIRE RETARDANT 1/2" EXTERIOR GRADE PLYWOOD VAPOR BARRIER 3" RIGID INSULATION AT PERIMETER MINERAL INSULATION - FILL ALL VOIDS SEALANT W/ BACKER ROD PERMEABLE WEATHER RESISTIVE BARRIER ZINC COMPOSITE MATERIAL FACADE SYSTEM METAL GUTTER STAY ATTACHED AT RAFTER AND MIDSPAN 4" MIN SPRAY-ON INSULATION: CLOSED-CELL SPF W/ R-6 PER 1” THICK ZINC COMPOSITE MATERIAL PANEL STRUCTURAL THERMAL BREAK PLATE COMPRESSIBLE FILL EXPANSION JOINT SELF ADHESIVE FLASHING ZINC FLASHING DRIP EDGE TERMINATION BAR ZINC FLASHING STEEL STIFFENER DOUBLE LOCK 1" STANDING SEAM ZINC ROOFING HYDROPHOBIC WEATHER-RESISTIVE BARRIER BREATHABLE DIMPLED UNDERLAYMENT HIGH TEMPERATURE UNDERLAYMENT 4" INSULATED ROOF DECKING COMPRISED OF 3/4" EXTERIOR GRADE PLYWOOD + 3 1/4" RIGID INSULATION. MIN R-21 VAPOR RETARDER SELF ADHESIVE PERMEABLE WEATHER RESISTIVE BARRIER EXPANSION JOINT ASSEMBLY COVER ELASTOMERIC MEMBRANE .060" SLOPED WELDED STAINLESS STEEL GUTTER LINER HOT FLUID APPLIED WATERPROOFING 1/2" RIGID INSULATION SSG ALUMINUM CURTAIN WALL SYSTEM SLOPED GLAZING ASSEMBLY EXTRUDED ALUMINUM ANODIZED GLASS TYPE 6. SEE GLASS TYPE LEGEND 1" INSULATED GLASS UNIT (IGU) - SEE ELEVATIONS SUSPENDED GYPSUM BOARD CEILING CERAMIC TILE - SEE FINISH SCHEDULE ALUMINUM 'F' SHAPE REVEAL MOLDING STAINLESS STEEL TILE EDGE LED STEPLIGHT THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB. EXISTING STONE PANEL CLADDING TO REMAIN
05.031
07.012 05.017 07.022
07.017
09.001
3"
07.009 08.004
SIDEWALK - SEE LANDSCAPE
SLOPED 08.019
5"
7 QQ
6
SECTION DETAIL
SECTION DETAIL
5
3" = 1'-0"
PLAN DETAIL 3" = 1'-0"
3" = 1'-0"
1' - 3" 07.016 05.025 05.019
1/2"
07.012
07.022 06.008
05.018
Murphy USA
3"
07.010
1/4"
07.017
1/4"
09.023
08.019
03.001
08.004 07.009
07.004
MAINTAIN UNOBSTRUCTED WEEP OUTLET
07.005 3/8"
3"
07.021 WRAP COLUMN
Commision #15054.00 200 Peach Street El Dorado, AR 71730
07.009 07.017 SLOPE 07.032 06.008
1/8" / 1'-0"
0.8 08.019
Westlake Reed Leskosky
05.018
07.012 05.046
3/4"
05.014
07.022
05.032
9"
TERMINATE INTUMESCENT COATING AT LINE OF WRB
07.037
07.020
7"
Checked by:
03.007
SLOPE
0.8
5" SLOPE
6"
Checker
07.018
FF
05.036
LAP WRB OVER BEAM
08.004 07.019
07.020 3/4"
07.019 07.017
07.017
07.009 07.012
32.002 E.022
1"
07.017
03.012
EXTERIOR DETAILS
07.010
Drawn by:
Author
03.007
07.016
07.012
05.036
05.025
3 5/8"
4
PLAN DETAIL 3" = 1'-0"
3
SECTION DETAIL 3" = 1'-0"
2
PLAN DETAIL 3" = 1'-0"
1/2"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
E.022
2"
1
PLAN DETAIL 3" = 1'-0"
CD
A-502
A
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
G
6"
4"
6"
4"
MAX.
U
6"
MAX.
05.016
1 1/2"
12/1/2015 4:24:00 PM
SECONDARY
07.017 07.009
1/8" / 1'-0"
07.011
1' - 0"
32.005
1/2"
8 1/2"
5 1/2"
3 1/2"
32.001
06.008 32.001
07.017
05.017
E.025 1/2"
07.017
General Notes
05.031 07.009
1/8" / 1'-0"
32.004
1. 2.
07.019 03.008 5 1/2"
ALIGN
4"
KEYNOTES 07.017
3/8"
3/8"
8"
03.006 03.008 03.009 03.012
CONC. FILL - SEE STRUCT.
03.009 05.024
03.012
8"
4"
POST WIDTH + 1" MIN
03.012
04.001
03.012
05.002 05.016 05.017
SECTION DETAIL
9
3" = 1'-0"
DETAIL - RAILING AT SLAB ON GRADE 6" = 1'-0"
E
SECTION DETAIL
8
3" = 1'-0"
G
3" = 1'-0"
6" 05.017
DETAIL - GRANITE @ SLAB EDGE 1"
06.008
32.004
32.005
32.001
07.009
1/8" / 1'-0"
05.025
07.009 07.011
0.0
07.013 07.017 07.019 07.031 10.006 22.010 22.011 26.005 32.001
6"
5 1/2"
1 1/2"
1 1/2"
3" = 1'-0"
1/2"
1' - 2"
05.024 05.025 05.028 05.029 05.031 05.038 06.008 07.007
1/2"
1' - 0"
SECTION DETAIL
26.005
6"
10
7
4"
11
SEE SHEET A-106 FOR ALTERNATE #2. SEE STRUCTURAL DRAWINGS FOR STEEL CANOPY GEOMETRY.
32.005
4"
32.002
32.002
01 FIRST FLOOR 0' - 0"
01 FIRST FLOOR 0' - 0"
3/4" MAX
3/4" MAX
05.002
0.0
6" 3/8"
1/8" / 1'-0"
ROUTE PIPING BELOW LIGHT FIXTURE
2"
32.002
6"
EQ
COVER
32.004 32.005 E.025
4"
05.016
1"
1/2" 1 1/2"
L/2
0.8
1' - 0"
07.007
26.005
1 1/2"
CAST IN PLACE CONCRETE FOOTING - SEE STRUCTURAL PREFORMED POST HOLE NON METALLIC NON SHRINK GROUT NEW CAST IN PLACE CONCRETE RETAINING WALL AND FOUNDATION. SEE STRUCT. PORTLAND CEMENT MORTAR BED W/ WIRE MESH REINFORCEMENT STEEL COLUMN W/ HOT DIPPED GALVANIZING AND HIGH PERFORMING COATING - SEE STRUC. STAINLESS STEEL RAILING 2" X 3/4" BAR STOCK 3/16" THK. CUSTOM STAINLESS STEEL PLATE W/SHOT BLASTED BLACK OXIDE FINISH STEEL ANGLE - SEE STRUCT. COLD FORM METAL FRAMING STAINLESS STEEL EDGE 1/2" DIA. X 6" LONG SS DOWEL 2 PER STONE STAINLESS STEEL Z CLIP ASSEMBLY SHIM AS REQUIRED CONT. STAINLESS STEEL ANGLE WITH SLOTTED CONNECTION 1/2" EXTERIOR GRADE PLYWOOD 2" X 3" ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER SEE CIVIL SEALANT W/ BACKER ROD EMBEDDED POST PROTECTED WITH CATALYZED POLYURETHANE 3.5" X 3.5" SQUARE ZINC DOWNSPOUT TO TIE INTO SITE STORM WATER - SEE CIVIL ZINC COMPOSITE MATERIAL PANEL COMPRESSIBLE FILL LATEX SCREED 5/8" GRIDLINE ENTRY MAT WITH HIDDEN LOCK DOWNS SLOT TRENCH DRAIN - SEE PLUMBING STORM WATER PVC PIPING - SEE PLUMBING UPLIGHT FIXTURE - SEE ELECTRICAL THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB. GRANITE STEP ON 1/2" SETTING BED GRANITE SLAB ON 1/2" SETTING BED EXISTING COMPOSITE DECK TO REMAIN
06.008
EQ
07.017
##.###
22.011
05.002
05.017 07.013
05.029
PLAN DETAIL
5
04.001
2"
1 1/2"
3" = 1'-0" 05.002 3"
1/4"
1/4"1 1/2"
03.006
01 FIRST FLOOR 0' - 0"
4"
05.017
1/4"
3"
05.038
05.038
32.004 05.017 05.031 22.011 VARIES
EASED EDGES 03.012
2 1/2"
1 1/2"
1' - 0"
1 1/2" 1 1/2"
2"
3' - 2"
3' VARIES - 2 1/2"
3" = 1'-0" 05.016
1 1/2"
2' - 2 3/4"
1' - 3"
2' - 6"
SECTION DETAIL @ STAIR
3/4"
6
1 1/2"
03.012
3"
3"
05.017
1/2"
05.038 1/4"
1/4" 3/8" / 1'-0"
1/8" / 1'-0"
07.009
05.031
05.017 32.002
05.017
32.004
1 1/2"
1' - 3"
1 1/2"
01 FIRST FLOOR 0' - 0"
3"
3' - 0"
22.010
3"
SLOPED
SEE LANDSCAPE
Murphy USA
VARIES
Commision #15054.00 200 Peach Street El Dorado, AR 71730
VARIES
Checker
4" MIN
03.012
4" MIN
Checked by:
Westlake Reed Leskosky
LINE OF WALL BEYONG
3"
2"
05.031
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350 32.002
EXTERIOR DETAILS
1/4" MAX SLOPED
07.031
MM
05.028 32.001
CD
Drawn by:
10.006
4
SECTION DETAIL 6" = 1'-0"
3
SECTION DETAIL 3" = 1'-0"
2
SECTION DETAIL 3" = 1'-0"
1
SECTION DETAIL - EMBEDDED DOWNSPOUT 3" = 1'-0"
A-503
12/1/2015 4:24:13 PM
SECONDARY Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
05.003
P
KEYNOTES
3' - 6"
2" EQ EQ
1 1/2"
08.009
GLASS GUARDRAIL 06.003 ALIGN JOINT W/GLASS
06.005
07.003
20
20
20 06.005
SEAL JOINTS BETWEEN WOOD AND GWB
06.005
(2) 3/4" GWB ON 1 5/8" CHANNELS. 2 HR. FIRE RATED COLUMN ENCLOSURE (UL X528)
FINISH SURFACE W/ BLACK P.LAM.
06.003 08.010 06.007
06.007
4"
12
PLAN DETAIL AT OVAL ENTRY WEST
11
3" = 1'-0"
05.003 05.010 06.003 06.004 06.005 06.007 07.003 08.009
06.007
06.005
FINISH FLOOR
##.###
08.010 08.011 09.010
STAINLESS STEEL RAILING CAP MISC. STEEL L-BRACING ARCHITECTURAL GRADE VENEER 1/2" PLYWOOD - SEE FINISH PLANS 1 3/4" WOOD DOOR SOLID WOOD FRAME/MOULDING WOOD SHIM - SURFACES TO BE PLUM AND LEVEL SILICONE SEALANT 10-5/16" DOUBLE GLAZED, LOW IRON, TEMPERED CHANNEL GLASS SYSTEM W/ CURVED TRACKS 1/2" TEMPERED, LOW-IRON GLASS GLASS GUARDRAIL W/S.S. STANDOFFS LIGHT GA. METAL FRAMING
06.003
PLAN DETAIL AT CHANNEL GLASS 3" = 1'-0"
08.011
05.010
10 N
3" = 1'-0"
P 11 A-511
05.010
6'-2 1/2" 5' - 7 1/2"
4' - 4"
7" 06.003
20
2"
3' - 8"
OVAL ENTRY PLAN DETAIL AT COL.
1 1/2"
06.007
12 A-511
10 A-511
06.005 07.003
4'-4 1/4"
08.010
8
OVAL ENTRY GLASS JAMB 3" = 1'-0"
4"
05.010
SECTION DETAIL - TYP. GLASS RAILING
08.010
CURTAIN POCKET FINISH INSIDE W/BLACK P.LAM.
7 A-511
21
7
5"
OVAL ENTRY JAMB DETAIL 3" = 1'-0"
2 4'-2"
A-432
3'-4"
REPLACE EXISTING RAILING WITH STAINLESS STEEL (S.S.) VERSION
06.005
2" 9'-11 1/2"
10"
9'-7 1/2"
CONT. S.S. RECTANGULAR LOW PROFILE GUARDRAIL CAP TO REPLACE EXISTING
8 A-511
1 1/2"
07.003
1 1/2" = 1'-0"
9'-11 1/2"
9
3-1/2" ACOUSTIC INSULATION BATTS TO UNDERSIDE OF STRUC. DECK.
06.004
EXISTING GLASS GUARDRAIL TO REMAIN IN PLACE
S.S. HEAVY DUTY SOSS HINGE
1 1/2"
2"
ACOUSTIC SEAL
06.005
2"
EXISTING GLASS SHOE TO RECEIVE STAINLESS STEEL WRAP. MINIMIZE JOINTS AND ADHERE PER MANUF. INSTRUCTIONS
5 A-511
1'-5 1/4"
06.007
06.003
22
5
OVAL ENTRY DOOR JAMB 3" = 1'-0"
FINISH FLOOR 1
Murphy USA
A-432
OVAL ENTRY ENLARGED PLAN 1" = 1'-0"
Checker
EXISTING GWB SURFACE TO REMAIN
6
ALLOW SPACE FOR GLASS SETTING
Commision #15054.00 200 Peach Street El Dorado, AR 71730
3/8" CLNG. REVEAL
2"
Checked by:
Westlake Reed Leskosky 06.005 07.003 06.003 08.010
4
OVAL ENTRY HEAD DETAIL 3" = 1'-0"
09.010
08.010
BM
1/16" THK. MAX. 06.003 ALUM. FLAT BAR FOR 06.007 RECESSED REVEAL
06.005 06.007
Drawn by:
1/2"
FIN. FLR. OVER CONC.
3
SECTION DETAIL - TYP. GLASS RAILING (ALT-1) 1 1/2" = 1'-0"
FIN. FLR. OVER CONC. CONT. BLACK SETTING BLOCK
SEE DEMO RCP PLANS
OVAL ENTRY BASE DETAIL 3" = 1'-0"
INTERIOR DETAILS
07.003
06.005
2
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
1
OVAL ENTRY SILL DETAIL 3" = 1'-0"
CD
A-511
12/1/2015 4:24:23 PM
PRIMARY
SCHEDULED PARTITION
JJ 1' - 3"
1' - 3"
3/4" CLOSED CELL DUROMETER (40+/-) NEOPRENE TAPE WITH PRESSURE SENSITIVE ADHESIVE & PEEL OFF COVER. COMPRESS TO 3/8", FLOOR TO CEILING HGT. IN ONE CONTINUOUS PIECE.
EDGE ALIGNMENT SHOWN (CONDITION VARIES): SEE FLOOR PLAN FOR EDGE OR CENTER ALIGNMENT CONDITIONS
1' - 3"
REFER TO FINISH SCHEDULE 8 7/8"
KEYNOTES
DASHED LINE DENOTES PARTITION AT PERPENDICULAR CONDITIONS - SEE FLOOR PLAN FOR LOCATIONS 05.023
E.018 SHEET WALL PROTECTION
1/4"
DOOR
CORNER BEAD (TYP.)
31
ACOUSTIC SEALANT (TYP.)
RESINOUS FLOORING RESINOUS FLOORING DIVIDER STRIP
CENTER LINE OF MULLION
RUBBER TRANSITION STRIP SIM. TO JOHNSONITE CTA-XX-K
09.010 09.014 27.001 E.018 FEC01
##.###
CONTINUOUS 20 GAUGE SHEET METAL BLOCKING AS REQUIRED LIGHT GA. METAL FRAMING 5/8" TYPE X GYPSUM WALL BOARD WALL MOUNTED MONITOR - SEE AV EXISTING STEEL COLUMN WITH SPRAY ON FIREPROOFING TO REMAIN SEMI-RECESSED FIRE EXTINGUISHER CABINET
TILE TYPICAL MULLION
3/8"
2" FOR FIELD VARIATION SKIM WALL LEVEL WITH FACE OF WALL PROTECTION
MOLDING AS SPECIFIED
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
BASE AS SCHEDULED
GLASS CONCRETE SLAB 27.001
27.001
FLOOR AS SCHEDULED
13
PARTITION PLAN DETAIL AT MULLLION 3" = 1'-0" J
14
CONCRETE TO CARPET FLOORING TRANSITION
05.023
05.023
1' - 2"
6" = 1'-0"
1' - 2"
5' - 0"
SECTION @ WALL PROTECTION
15
3 1/2"
12" = 1'-0"
09.014 DOOR DOOR
09.010
CERAMIC TILE FLOORING CERAMIC TILE FLOORING
METAL TRANSITION SCHLUTER SCHIENE AE100 SATIN ANODIZED ALUMINUM FINISH CARPET FLOAT AS SHOWN
1:25 MAX. SLOPE DOWN
EXISTING EXTERIOR ENVELOPE
3/8"
3/8"
CONCRETE SLAB
1/16"
METAL TRANSITION SCHLUTER RENO-V #AEVT100B20 SATIN ANODIZED ALUMINUM FINISH SEALED CONCRETE OR RESILIENT FLOORING
3 1/2"
MIN. GROUT JOINT
MIN. GROUT JOINT
CONCRETE SLAB
32 FEC01
12
TILE TO CONCRETE OR RESILIENT FLOORING TRANSITION 12" = 1'-0"
11
TILE TO CARPET FLOORING TRANSITION
10
12" = 1'-0"
CUSTOMER EXPERIENCE DISPLAY WALL
9
1 1/2" = 1'-0"
PLAN DETAIL - FIRE RATED SHAFT 1 1/2" = 1'-0"
DOOR DOOR CERAMIC TILE FLOORING
CARPET
MIN. GROUT JOINT METAL TRANSITION SCHLUTER RENO-V #AEVT100B20 SATIN ANODIZED ALUMINUM FINISH
RUBBER TRANSITION STRIP SIM. TO JOHNSONITE CTA-XX-HT
CONCRETE OR RESILIENT FLOORING 3/8"
RESILIENT FLOORING
2MM 1/16"
1/4"
CONCRETE SLAB
8
CONCRETE SLAB
CARPET TO RESILIENT FLOORING TRANSITION 12" = 1'-0"
7
TERRAZZO TO CONCRETE OR RESILIENT FLOORING TRANSITION 12" = 1'-0"
DOOR CARPET FLOAT TO ALIGN TOP OF CARPET PILE WITH TOP OF ADJACENT CARPET SEAL SEAM AS REQUIRED
DOOR
3/8"
3/8"
1/16"
3/8"
CARPET
1:25 MAX. SLOPE DOWN
CARPET FLOAT TO ALIGN TOP OF CARPET PILE WITH TOP OF FINISHED FLOOR
1:25 MAX. SLOPE DOWN
3/8"
3/8"
3/8"
1/4"
1/4"
METAL TRANSITION SCHLUTER SCHIENE AE100 SATIN ANODIZED ALUMINUM FINISH
CONCRETE SLAB
WAINSCOT TRIM (25N036XXX)
CARPET TO CARPET FLOORING TRANSITION 12" = 1'-0"
5
TERRAZZO TO CARPET FLOORING TRANSITION 12" = 1'-0"
4
METAL "J" TRIM
OUTSIDE CORNER (25N032XXX)
BUTT JOINT
INSIDE CORNER (25N035XXX)
"H" JOINT MOLDING (25N033XXX)
WHERE CAULKED BUTT JOINT IS NOT SPECIFIED
FOR SOILED AND CLEAN UTILITIES AND HOUSEKEEPING
Murphy USA
CAULKED BUTT JOINT TYP., UNO
SHEET WALL PROTECTION TRIM PIECES
Commision #15054.00 200 Peach Street El Dorado, AR 71730
12" = 1'-0"
R
Checked by:
Checker
CONCRETE SLAB
6
3/ 8"
TERRAZZO FLOORING
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
DOOR
DOOR SEALED CONCRETE
(2) 3/4" GWB ON 1 5/8" CHANNELS. 2 HR. FIRE RATED COLUMN ENCLOSURE (UL X528)
TERRAZZO FLOORING RUBBER TRANSITION STRIP SIM. TO JOHNSONITE CTA-XX-J
METAL TRANSITION SCHLUTER SCHIENE AE100 SATIN ANODIZED ALUMINUM FINISH
CARPET
CONCRETE SLAB
CD
Drawn by:
CONCRETE SLAB
3
CONCRETE TO CARPET FLOORING TRANSITION 12" = 1'-0"
2
TERRAZZO TO CERAMIC TILE FLOORING TRANSITION 12" = 1'-0"
INTERIOR DETAILS
3/8"
3/8"
Author
1/4"
CERAMIC TILE FLOORING
25
1
FIRE RATED COL. WRAP 1 1/2" = 1'-0"
A-512
12/1/2015 4:24:32 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
ACOUSTIC PARTITION DETAILS
CONTINUOUS ACOUSTICAL SEALANT AROUND ENTIRE PERIMETER (TYP.)
24" MIN.
1/8" CLEAR TYP. (CONDUIT OR PIPE SHALL NOT CONTACT WALL)
TYPICAL OUTLET BOX
BOX PAD (TYP.) SIMILAR FOR DOUBLE STUD PARTITION
ACOUSTICAL SEALANT
SCHEDULED PARTITION
SINGLE CONDUIT, CABLE OR PIPE
TYPICAL SINGLE STUD PARTITION WITH SOUND ISOLATION 24" MIN.
CAULKING COMPOUND, CLOSED CELL POLYURETHANE FOAM OR FIRE RATED SILICONE FOAM
SCHEDULED PARTITION
SIMILAR FOR SINGLE STUD PARTITION
1/2" CLEAR (TYP.)
TYPICAL DOUBLE STUD PARTITION (SIMILAR FOR STAGGERED STUDS) WITH SOUND ISOLATION
MULTIPLE CONDUIT
NOTE: SEPARATE CONDUIT FOR OUTLET BOXES ON 2 SIDES OF PARTITION. NO CONTACT BETWEEN STUDS
CONDUIT SLEEVE CAULKING COMPOUND, CLOSED CELL POLYURETHANE FOAM OR FIRE RATED SILICONE FOAM
NOTES: 1. PLACE OUTLET BOXES IN SEPARATE STUD SPACES 2. BACK-TO-BACK OUTLETS NOT PERMITTED. 3. PLUG ALL UNUSED KNOCK-OUTS IN OUTLET BOXES WITH KNOCK-OUT CAPS. 4. PROVIDE BACKING EQUIVALENT TO "LOWRY'S" OUTLET BOX PADS (HARRY A. LOWRY & ASSOCIATES INC. (800) 225-8231) 5. DEPTH OF OUTLET BOX MUST BE COMPATIBLE WITH STUD SIZE IN ORDER TO ACCOMMODATE BOX PAD. 6. ACOUSTICAL BOX PAD REQUIREMENT APPLIES TO ALL PARTITIONS WITH ACOUSTICAL INSULATION. 7. USE OF MUD RINGS WITHOUT ELECTRICAL BOXES SHOULD NOT BE ALLOWED.
1/8" CLEAR TYP. (CONDUIT OR PIPE SHALL NOT CONTACT WALL)
SLEEVE W/MULTIPLE CABLES
PENETRATIONS OF ACOUSTICAL PARTITIONS BY, CONDUIT, CABLE, PIPES ETC. SHALL BE ACOUSTICALLY SEALED AS SHOWN. ANY GAP LARGER THAN 1/2" SHALL BE COVERED WITH GYPSUM BOARD, LAPPED A MINIMUM OF 2" AND SCREWED BEFORE USING ACOUSTICAL SEALANT. CABLE TRAYS SHOULD NOT PENETRATE SLAB-TO-SLAB PARTITIONS. A CONDUIT SLEEVE SHOULD BE USED AT SUCH PENETRATIONS AND SEALED AS SHOWN ON THIS DETAIL. FLEXIBLE DUCT, PIPE, CONDUIT, ETC. CONNECTIONS SHOULD BE INCORPORATED BETWEEN ROOMS WHERE RESILIENTLY ISOLATED FLOORS, WALLS OR CEILING LIDS OCCUR.
APPLIES TO POWER, PHONE, COMMUNICATIONS, ETC.
4
OUTLET BOX DETAILS
3
3" = 1'-0"
PARTITION PENETRATION DETAILS 3" = 1'-0"
STRUCTURE ABOVE
ACOUSTICAL SEAL (SEE DETAIL)
CONTINUOUS METAL RUNNER SCHEDULED PARTITION
THERMAL INSULATION WHERE OCCURS
Murphy USA
Checker
Commision #15054.00 200 Peach Street El Dorado, AR 71730 COLUMN ENCLOSURE SLAB TO SLAB
Checked by:
Westlake Reed Leskosky AIR DUCT 1/2" GAP
CONTINUOUS ACOUSTICAL SEALANT TO CLOSE OFF GAP
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
CEILING AS SCHEDULED
Drawn by:
Author
INTERIOR DETAILS PENETRATIONS OF ACOUSTICAL PARTITIONS BY DUCTWORK SHALL BE ACOUSTICALLY SEALED AS SHOWN. ANY GAP LARGER THAN 1/2" SHALL BE COVERED WITH GYPSUM BOARD, LAPPED A MINIMUM OF 2" AND SCREWED BEFORE USING ACOUSTICAL SEALANT.
2
DUCT PENETRATION OF ACOUSTIC PARTITION 3" = 1'-0"
SCHEDULED PARTITION
1
PARTITION INTERSECTION @ FURRED COLUMN (TYP) 3" = 1'-0"
CD
A-513
1
2
A-532
A-532
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
ALIGN
12/1/2015 4:24:43 PM
PRIMARY
3/4" SOLID SURFACE
FILE CABINET
1
2
A-532
A-532
U 4 A-531 4
EQ
A-531
EQ
EQ 2"
9' - 0"
3"
2"
10
1' - 3" ALIGN
BASE
RECEPTION DESK CABINETS NORTH 1/4" = 1'-0" 3
2' - 2"
ALIGN
A-532
10
A-531
9
RECEPTION DESK SOUTH 1/4" = 1'-0"
5 5
4
A-532
A-532
LINE OF DESKTOP
1
2
A-531
A-531 ALIGN
1' - 6"
9' - 8"
2' - 3"
6' - 1"
9"
1' - 2"
V
FILE CABINET 3' - 2 13/16"
3 A-532
A-531
2' - 5 1/16"
3
8
A-531
RECEPTION DESK NORTH 1/4" = 1'-0"
FILE CABINET
5
4
1
2
A-532
A-532
A-531
A-531
15' - 7" 10' - 9"
4' - 10"
9
A-531
9 3/4"
8
RECEPTION DESK EAST 1/4" = 1'-0"
3"
7 3/4" BASE WOOD VENEER
ALIGN WOOD VENEER FORM ABOVE
8' - 11"
4
5
A-531
A-532
A-532
4' - 10"
WOOD VENEER FORM ABOVE
15' - 7"
30
3/4" SOLID SURFACE ON 3/4" PLYWOOD
29
28
A-531
RECEPTION DESK - ENLARGED PLAN
3 A-532
3 A-531
7
6
1
A-531
6' - 8" 10' - 9"
31
2
5
1 1/2" = 1'-0"
RECEPTION DESK WEST 1/4" = 1'-0"
4' - 2" 6"
1' - 3"
2' - 5"
3/8" SOLID SURFACE COUNTER TOP 1' - 9"
2' - 5"
WOOD VENEER PANEL 8"
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
3/4" SOLID SURFACE
Commision #15054.00 200 Peach Street El Dorado, AR 71730
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
PLAM ON 3/4" SUBSTRATE
Author
2"
4" 3"
4
RECEPTION DESK DETAIL 0 1 1/2" = 1'-0"
3
RECEPTION DESK DETAIL 1 1 1/2" = 1'-0"
2
RECEPTION DESK DETAIL 2 1 1/2" = 1'-0"
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
MILLWORK DETAILS
WIRE PULL
BASE, SEE FINISH SCHEDULE
2' - 6"
2' - 4"
2' - 6" 1' - 2"
FILE DRAWER W/ LOCK
3/4" SOLID SURFACE
2"x2"x1/4" STEEL ANGLE COUNTER SUPPORT AT 2'-8" O.C. MAX W/ WELDED STEEL GUSSET PLATE MAY OCCUR
2' - 10"
5"
2' - 10"
FILE CABINET
2' - 6"
BASE CABINET
DRAWER
Westlake Reed Leskosky 3' - 6"
DRAWER
5"
ALIGN
2"
2"
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
2' - 10"
Checked by:
Checker
SOLID SURFACE
Drawn by:
Murphy USA
4' - 2"
9"
CD 1
RECEPTION DESK DETAIL 3 1 1/2" = 1'-0"
A-531
PRIMARY 12/1/2015 4:24:50 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
3' - 8" 1' - 3"
2' - 5"
3/8" SOLID SURFACE COUNTER TOP
1' - 0"
WOOD VENEER PANEL
5"
DRAWER
1' - 2"
FILE DRAWER W/ LOCK
3"
WIRE PULL
4"
1' - 0"
PLAM ON 3/4" SUBSTRATE
BASE, SEE FINISH SCHEDULE
5
3' - 6"
3' - 6"
DRAWER
5"
ALIGN
2' - 6"
2"
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
3"
A-532
5
RECEPTION DESK DETAIL 4 1 1/2" = 1'-0"
3' - 8" 1' - 3"
2' - 5"
Murphy USA
2' - 2" 3/8" SOLID SURFACE COUNTER TOP
3/8" SOLID SURFACE COUNTER TOP
1 1/2" = 1'-0"
2"
3/4" BOTTOM PANEL
RECEPTION DESK DETAIL 6 1 1/2" = 1'-0"
EQ
MILLWORK DETAILS
BLOCKING, TYPICAL
BASE, SEE FINISH SCHEDULE
4"
3 3/4"
BASE, SEE FINISH SCHEDULE 3"
3"
2
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
3/4" BOTTOM PANEL
BLOCKING, TYPICAL
SILL PLATE W/1/4" DIA. X 1-3/4" LONG HILTI KWIK-CONN INTO CONC. @ 18" O.C.
2' - 6"
2' - 0" FILE DRAWER W/ LOCK
P.LAM. ON 3/4" SUBSTRATE
P.LAM. ON 3/4" SUBSTRATE
1' - 0"
3
1/4" BACKING PANEL
EQ
1/4" BACKING PANEL
2' - 6"
1' - 7 1/4"
2' - 4"
WIRE PULL
11 3/4"
4
ALIGN
3' - 6"
3' - 6" 2' - 4"
1' - 2"
AH
1' - 0"
FILE CABINET
BASE, SEE FINISH SCHEDULE
Drawn by:
WIRE PULL
ADJUSTABLE SHELVES ON PIN-TYPE SUPPORTS
POWER & TECH MAY OCCUR REFER TO ELEC. & TECH DWGS.
RECEPTION DESK DETAIL 5
ALIGN
2' - 6"
2"
2" 2' - 6" 3' - 6"
3"
COORDINATE BRACKET LOCATION W/ UNDERMOUNT KEYBOARD TRAY. PROVIDE BLOCKING AS REQ.
Westlake Reed Leskosky
FILE DRAWER W/ LOCK
COORDINATE GROMMETS WITH WORKSTATIONS
BASE, SEE FINISH SCHEDULE
SEALANT
SEALANT
DRAWER
2"x2"x1/4" STEEL ANGLE COUNTER SUPPORT AT 2'-8" O.C. MAX W/ WELDED STEEL GUSSET PLATE MAY OCCUR
Commision #15054.00 200 Peach Street El Dorado, AR 71730
2"
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" PLYWOOD
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" SUBSTRATE
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" SUBSTRATE
5"
DIAGONAL CROSS BRACING @ EACH VERTICAL FRAME
WOOD VENEER PANEL
1' - 0"
WOOD VENEER PANEL
Checked by:
Checker
MONITOR AND MONITOR ARM
RECEPTION DESK DETAIL 7 1 1/2" = 1'-0"
1
RECEPTION DESK DETAIL 8 1 1/2" = 1'-0"
CD
A-532
PRIMARY 12/1/2015 4:25:06 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT GREATER THAN OR EQUAL TO 'X'
FAUCET MOUNTED TO FACE OF MIRROR
SPOUT
FAUCET TOUCHLESS SENSOR MOUNTED TO FACE OF MIRROR
ALIGN
X
9 1' - 6"
A-533
7' - 2 3/4"
SHIPLAP JOINT
MICROSOFT SURFACE HUB (84")
2' - 10"
CORK BACKING
MICROSOFT SURFACE HUB 84" MOUNTING HARDWARE
MICROSOFT SURFACE HUB MOUNTING HARDWARE
MICROSOFT SURFACE HUB (84")
4' - 6"
9' - 0"
11"
3' - 10 1/8"
9' - 0"
2' - 1 3/4"
2" WIRE MGMT ACCESS
PROVIDE WIRE MANAGEMENT ACCESS
WOOD VENEER BEYOND
6' - 6"
6' - 6"
POWER RECEPTACLE, SEE ELEC.
11
DETAIL - LOBBY TOILET ROOM SINK 1 1/2" = 1'-0"
1' - 9" U.N.O. WOOD VENEER
FAUCET MOUNTED TO FACE OF MIRROR OVERFLOW HOLES OCCUR AT PUBLIC RESTROOMS
SEALANT
PLYWOOD FRAME FIT AROUND STEEL COUNTER SUPPORTS
EXTRUDED ALUMINUM PULLTYPE REVEAL
1' - 6 1/4"
3/4" PLYWOOD SUBSTRATE
IN-WALL STL. COUNTER SUPPORT ANCHORED TO 16 GA STUDS. SUPPORTS 1,000 LBS. OFFSET TRAP TO CLEAR VALENCE PANEL
2' - 10"
P. LAM. SHELF ON PIN-TYPE SUPPORTS
ALIGN
WIRE MANAGEMENT ACCESS
2' - 3 1/2"
P. LAM. ON 3/4" SUBSTRATE P. LAM. BACK PANEL, COLOR TO MATCH CABINET INTERIOR
2" WIRE MGMT ACCESS DATA RECEPTACLE, SEE TECH. POWER RECEPTACLE, SEE ELEC.
1 1/2" 5"
1 3/4"
SOLID SURFACE COUNTERTOP
FAUCET TOUCHLESS SENSOR MOUNTED TO FACE OF MIRROR
SOLID SURFACE TOP W/ INTEGRAL SINK BOWLS, INTEGRAL BACKSPLASH, LOOSE SIDE SPLASH(ES). NO DRIP EDGE
PROVIDE REMOVABLE ATTACHMENT AT PANEL, PROVIDE FIXED END PANEL OF SAME CONSTRUCTION FOR ATTACHMENT IF NO PARALLEL WALL OCCURS.
4"
0"
1/4" WOOD TRIM BASE, SEE FINISH SCHEDULE 8"
9' - 9"
1 1/2"
3"
CONT. SILL PLATE W/(5) 1/4" DIA. X 1-3/4" LONG HILTI KWIKCONN INTO CONC. @ 24" O.C.
10' - 0"
10
TEAMING AREA STORAGE AND TV DISPLAY 1 1/2" = 1'-0"
TEAMING AREA TV HOUSING AND CABINETRY
9
3
4
A-533
A-533
1 1/2" = 1'-0"
8
COUNTER W/ SINK 1 1/2" = 1'-0"
P.LAM. COUNTERTOP ON 3/4" SUBSTRATE
LINE OF COUNTERTOP ABOVE
SEALANT
SOLID SURFACE RETURN ON SUBSTRATE
4" BACKSPLASH MAY OCCUR, REFER TO ELEVATIONS
P.LAM. SOFFIT MAY OCCUR FIXTURE TYPE F26 SEE ELEC. DWGS
3' - 0"
DRAWER
6" X 20 GA CONTINUOUS REINFORCING PLATE
BASE SEE FINISH SCHEDULE
ADJUSTABLE SHELVES ON PIN-TYPE SUPPORTS
1' - 10 1/2"
BASE SEE FINISH SCHEDULE
2' - 10"
2' - 0"
WIRE PULL REFRIGERATED DISPLAY CASE
REFRIGERATED DISPLAY CASE
6" X 20 GA CONTINUOUS REINFORCING PLATE
VARIES, REFER TO ELEVATIONS
5 1/2"
2"
4"
1' - 0"
2' - 0" U.N.O.
BASE, SEE FINISH SCHEDULE
1 1/2"
1 1/2"
5 15/16"
1/4" BACKING PANEL
ADJUSTABLE SHELVES ON PIN-TYPE SUPPORTS
P.LAM. ON 3/4" SUBSTRATE 1/4" BACKING PANEL
P.LAM. ON 3/4" SUBSTRATE
6" X 20 GA CONTINUOUS REINFORCING PLATE WIRE PULL
2"
ALIGN
VARIES - REFER TO INTERIOR ELEVATIONS
4' - 0"
VARIES - REFER TO INTERIOR ELEVATIONS
4"
ALIGN
2"
3/4" BOTTOM PANEL
2"
3"
BASE, SEE FINISH SCHEDULE
FIXTURE TYPE F27 SEE ELEC. DWGS 1' - 0"
BLOCKING, TYPICAL
VARIES - REFER TO ENLARGED PLANS
KITCHEN / COFFEE BAR DETAIL PLAN
7
6
1 1/2" = 1'-0"
COPY ROOM BASE CABINET
5
1 1/2" = 1'-0"
WALL CABINET
Murphy USA
1 1/2" = 1'-0"
2' - 0" U.N.O.
SOLID SURFACE COUNTERTOP ON (2) 3/4" SUBSTRATE
P.LAM. ON 3/4" SUBSTRATE SOLID SURFACE BEYOND
1/4" BACKING PANEL
P.LAM. ON 3/4" SUBSTRATE
P.LAM. ON 3/4" SUBSTRATE
ADJUSTABLE SHELVES ON PIN-TYPE SUPPORTS
4
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
MILLWORK DETAILS
4"
3"
1' - 0"
KITCHEN / COFFEE BAR DETAIL @ U.C. REFRIDGERATOR 1 1/2" = 1'-0"
BASE, SEE FINISH SCHEDULE
3
2' - 0"
1' - 0"
KITCHEN / COFFEE BAR DETAIL @ CABINET 1 1/2" = 1'-0"
BLOCKING, TYPICAL
2
3"
SINK BASE CABINET 1 1/2" = 1'-0"
4"
2' - 0"
Commision #15054.00 200 Peach Street El Dorado, AR 71730
1/4" BACKING PANEL 3/4" BOTTOM PANEL
3/4" BOTTOM PANEL
BLOCKING, TYPICAL
4"
Drawn by:
4"
AH
3/4" BOTTOM PANEL BASE, SEE FINISH SCHEDULE BASE CABINET BEYOND
6" X 20 GA CONTINUOUS REINFORCING PLATE
WIRE PULL
1' - 10 1/2"
1/4" BACKING PANEL
1' - 10 1/2"
A-533
WIRE PULL
2' - 10"
7
ADJUSTABLE SHELF ON PIN-TYPE SUPPORTS
1' - 10 1/2"
A-533
SOLID SURFACE BEYOND
2' - 10"
2' - 8"
2' - 10"
REFRIGERATED DISPLAY CASE
DRAWER
SINK (SEE PLUMBING)
WIRE PULL
7
5 1/2"
5 1/2"
SOLID SURFACE
4" BACKSPLASH MAY OCCUR, REFER TO ELEVATIONS
2"
4" BACKSPLASH MAY OCCUR, REFER TO ELEVATIONS 6" X 20 GA. CONTINUOUS METAL REINFORCING PLATE
2"
DRAWER
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" SUBSTRATE SEALANT
SEALANT
2" 5 1/2"
ALIGN
Checked by:
P. LAM ON 3/4" SUBSTRATE
2' - 0" U.N.O.
2' - 10"
3' - 0"
2"
Checker
3' - 0"
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" SUBSTRATE
SOLID SURFACE COUNTERTOP ON (2) LAYERS 3/4" SUBSTRATE
BASE, SEE FINISH SCHEDULE
1
3"
BASE CABINET W/ DRAWER 1 1/2" = 1'-0"
BLOCKING, TYPICAL BASE, SEE FINISH SCHEDULE
CD
A-533
PRIMARY 12/1/2015 4:25:17 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
1
0.8
1/4" CURVED GWB ON EA. SIDE OF 3 5/8" MTL STUDS @ 24" O.C. W/3-1/2" ACOUSTIC INSULATION BATTS - SEAL ALL GAPS AND PENETRATIONS
REPAIR EXISTING SPRAYED ON FIREPROOFING AS REQ'D. 3/8" MIN
STEEL ANGLE BRACING LIGHT GA. FRAMING AND BRACING TO STRUC. DECK
DENOTES BTM. OF EXIST. W33 BEAM SUSPENDED GYPSUM BOARD CEILING
RECESSED CHANNEL GLASS TRACK
ARCH. FIN. GRADE SOLID WD. FRAME
MAXIMIZE HGT UNDER EXISTING W33 BEAM
1/4" CURVED GWB PREFINISH WHITE
1/4" CURVED GWB ON MTL FRAMING
1 1/2"
3/8" EXTRUDED ALUM. REVEAL
SUPPLY AIR JET NOZZLE - SEE MECHANICAL
3/8" CURVED "W' REVEAL SEE RCP FOR CEILING INFO.
SEE RCP FOR CEILING TYPE ARCH. FIN. GRADE PLYWOOD VERTICAL WD. FRAME BEYOND
11
SEE RCP FOR CEILING INFO.
2"
SEE RCP FOR CEILING HEIGHT
CURTAIN TRACK
OVAL CONFERENCE ENTRY CONDITION
10
3" = 1'-0"
COLD FORM METAL FRAMING LIGHT GA. BLACK OXIDE COATED STEEL WITH CLEAR SEALER LAMINATED TO 3/4" FIRE RETARDANT PLYWOOD
OVAL CONF. PERIMETER SOFFIT AT 2ND FLOOR CEILING
3/8" ALUMINUM REVEAL
3" = 1'-0" LED DOWNLIGHT - SEE F2B ELECTRICAL
RETURN AIR SLOT - SEE MECHANICAL
4 1/2"
ALIGN TO EXISTING STONE PANEL BEYOND
SUSPENDED GYPSUM BOARD CEILING
N
9 NEW BEAM ONLY TO SUPPORT DOOR (NOT PART OF SUPER STRUCTURE, FIRE PROOFING NOT REQ'D.) - SEE STRUCT DWGS
EXPOSED BEAMS, DUCTS, CONDUITS, ETC TO BE PAINTED, SEE FINISH SCHEDULE
OPERABLE PARTITION +/- 2' - 8", SEE RCP
GYP BD CEILING
EXISTING MODULAR WALL ASSEMBLY
DETAIL - CEILING @ OPERABLE PARTITION
7
3" = 1'-0"
DETAIL - EXPOSED CEILING @ MODULAR WALL 1 1/2" = 1'-0"
FIXTURE TYPE F19 SEE ELEC. DWGS ACT CEILING KNIFE EDGE TRIM
GYP BOARD CEILING
DETAIL - KNIFE PROFILE HEIGHT TRANSITION
6
3" = 1'-0"
5
ACT CEILING GYP BD CEILING
SEE RCP FOR CEILING HEIGHT
EXISTING GWB ABOVE MODULAR WALL
SEE RCP FOR CEILING HEIGHT
ACT CEILING SOFFIT EXTENDER
EXTRUDED ALUM. CEILING TRIM
SEE RCP FOR CEILING HEIGHT
CABLE MOUNTED LIGHT FIXTURE, FIXTURE TYPE F5 SEE EL-DWGS SEE RCP FOR CEILING HEIGHT
ALIGN
CONTINOUS ACOUSTICAL SEAL
SEE RCP FOR CEILING HEIGHT
BOLTED CONNECTION SHOWN SECURE TO STEEL PER PARTITION MANUF. RECOMMENDATIONS
SEE RCP FOR CEILING HEIGHT
3" = 1'-0"
CONTINUE GWB HEADER ABOVE MODULAR WALL: 5/8" GWB ON LIGHT GA. FRAMING UP TO STRUC. DECK
2 LAYERS OF 5/8" GYP BD, ON 1-5/8" LIGHT GA. FRAMING, EACH SIDE
8
DETAIL - HEIGHT TRANSITION @ ENCLOSED PATIO
DETAIL - HEIGHT TRANSITION GYP - ACT 1 1/2" = 1'-0"
19
Murphy USA
Checked by:
Checker
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
PROVIDE LIGHT GA. OVERHEAD BRACING TO STRUC. DECK
EXTRUDED ALUM. CEILING TRIM
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
4
3/8" ALUM. REVEAL
3
DETAIL - LEVEL CHANGE @ ACT-ACOUS. PLASTER 1 1/2" = 1'-0"
SCHEDULED CEILING RECESSED MOTORIZED PROJECTOR SCREEN
2
DETAIL - PROJECTOR SCREEN 1 1/2" = 1'-0"
SEE RCP FOR CEILING HEIGHT
ACOUSTIC PLASTER CEILING
SEE RCP FOR CEILING HEIGHT
ACOUSTIC PLASTER CEILING
DETAIL - ACOUSTIC PLASTER - GYP 3" = 1'-0"
SEE RCP FOR CEILING HEIGHT
GYP. BOARD CEILING
ACT CEILING
CEILING DETAILS SCHEDULED CEILING PROJECTOR
1
DETAIL - PROJECTOR 1 1/2" = 1'-0"
SEE RCP FOR CEILING HEIGHT
Drawn by:
Author
SEE RCP FOR CEILING HEIGHT
PROVIDE LIGHT GA. OVERHEAD BRACING TO STRUC. DECK
CD
A-561
PRIMARY 12/1/2015 4:25:27 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
LIGHT FIXTURE PER ELEC. DWGS COORDINATE OPENING SIZE
3 5/8" MTL STUDS W/ ACCOUSTIC INSULATION STEEL ANGLE BRACING NOTE: PARTITION BRACING MUST ALLOW SPACE FOR HVAC
SCHEDULED CEILING, SEE RCP
14
SEE RCP FOR CEILING HEIGHT
SEE RCP FOR CEILING HEIGHT
GYP. BOARD
SEE RCP FOR CEILING HEIGHT
METAL FURRING CHANNELS AND SUPPORTS
DETAIL - COVE LIGHT @ BATHROOM WALL 3" = 1'-0"
13
3/8" ALUM. REVEAL
GYP BD CEILING ACT CEILING
OFFSET SLOT DIFFUSER - SEE MECH.
GLAZING CHANNEL
SEE PLAN FOR PARTITION TYPE
ACT CEILING
5/8" GYP BD CEILING
DETAIL - GYP - ACT
12
3" = 1'-0"
DETAIL - ACT TO GYP TRANSITION @ GLASS PARTITION 3" = 1'-0"
PROVIDE 3 5/8" METAL STUD FRAMING AT PERIMETER, BRACE TO STRUCTURE ABOVE AS NEEDED
EXISTING AIR DIFFUSER EXISTING WALL
REFER TO MEACHANICAL DRAWINGS FOR LOCATION OF ABOVE-CEILING EQUIPMENT REQUIRING ACCESS NEW BLACKOUT DRAPE ON EXISTING TRACK
11
WALL MOLDING ACT CEILING
ACOUSTIC PLASTER CEILING
SEE RCP FOR CEILING HEIGHT
SEE RCP FOR CEILING HEIGHT
SEE RCP FOR CEILING HEIGHT
MOTORIZED SHADE
ACT CEILING 3/8" ALUM. REVEAL
LOCKABLE ACCESS PANEL DOOR W/ 5/8" GYP. BOARD INFILL. PAINT TO MATCH ADJACENT CEILING
DETAIL - SHADE @ EXECUTIVE SUITE 3" = 1'-0"
SEE REFLECTED CEILING PLAN
DETAIL - WINDOW SHADE @ EXTERIOR WALL
10
3" = 1'-0"
DETAIL - ACOUSTIC PLASTER - ACT
9
8
3" = 1'-0"
DETAIL - ACCESS PANEL 3" = 1'-0"
WALL BEYOND 9
5/ 8"
GYP BD CEILING
DETAIL - COVE LIGHT @ LOBBY
DETAIL - LINEAR DIFFUSER @ TECHZONE CEILING
5
3" = 1'-0"
4
3" = 1'-0"
ACT CEILING
DETAIL - ACT - EXPOSED - ACT 1 1/2" = 1'-0"
Murphy USA
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
5/8" GYP. BD. PAINTED
ALIGN
Author
SEE RCP FOR CEILING HEIGHT
WALL BEYOND
ACT CEILING
Drawn by:
EDGE OF WALL BEYOND
3
DETAIL - ACT @ WALL 3" = 1'-0"
2
ACT CEILING EXTRUDED ALUM. EDGE TRIM
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
ANGLE MOLDING
ALIGN SOFFIT W/ WALL BEYOND
CORNER BEAD TRIM
DETAIL - HEIGHT TRANSITION - ACT - GYP W/ INTERIOR ACT EDGE TRIM 3" = 1'-0"
GYP CEILING
GYP CEILING
SEE RCP FOR CEILING HEIGHT
SEE RCP FOR CEILING HEIGHT
Checked by:
EXTRUDED ALUM. EDGE TRIM
5/8" GYP. BD. CEILING
SEE RCP FOR CEILING HEIGHT
6
EXTRUDED ALUM. EDGE TRIM
SEE RCP FOR CEILING HEIGHT
3" = 1'-0"
ACT CEILING
3/8"
DETAIL - HEIGHT TRANSITION - ACOUSTIC PLASTER - GYP.
Checker
7
SPLINE CLIP
COLUMN, BEAMS, AND DUCTS TO BE PAINTED, SEE FINISH SCHEDULE
COLUMN BEYOND
SEE RCP FOR CEILING HEIGHT
ACOUSTIC PLASTER
SEE RCP FOR CEILING HEIGHT
FIBERGLASS MESH TAPE
ACOUSTIC PLASTER CEILING
3 1/2"
SEE RCP FOR CEILING HEIGHT
1' - 0"
SEE RCP FOR CEILING HEIGHT
CORNER BEAD TRIM PER ACOUSTIC PLASTER MANUF.
0' -
CONTINUOUS KNIFE EDGE CEILING TRIM,TAPED AND SPACKLED. FIXTURE TYPE F18 SEE ELEC. DWGS
SEE RCP FOR CEILING HEIGHT
SEE RCP FOR CEILING HEIGHT
R
SEE RCP FOR CEILING HEIGHT
1/4" BENT GYP BD, TAPED AND SPACKLED
ALIGN TRIM WITH FACE OF COLUMN
5/8" GYP BD CEILING
ALIGN TRIM WITH FACE OF COLUMN
ANGLE MOLDING
SEE RCP FOR CEILING HEIGHT
19
WALL BEYOND
1
DETAIL - HEIGHT TRANSITION - GYP - GYP 3" = 1'-0"
CEILING DETAILS
CD
A-562
12/1/2015 4:25:37 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT 2" WIDE x 14 GAUGE, COLD FORMED PLATES @ 16" O.C. ATTTACHED TO DECK FLUTES 14 GA. STL. PLATE AS REQ'D TOP OF STEEL DECK FILL VOID AREAS W/ SOUND INSUL., FOR SMOKE PARTITIONS SMOKESTOP ALL VOID AREAS TIGHT TO UNDERSIDE OF STRUCTURAL W/ SAFING
FIRESTOP W/ U.L. OR W.H.I. APPROVED (1) HR. JOINT FIRESTOP SYSTEM.
FIRESTOP W/ U.L. OR W.H.I. APPROVED (1) HR. JOINT FIRESTOP SYSTEM.
FILL ALL VOID AREAS TIGHT TO UNDERSIDE OF STRUCTURE WITH MINERAL WOOL FIRE SAFING
NOTE: REFER TO FLOOR PLANS FOR WALL GRAPHIC LOCATIONS THAT REQUIRE A LEVEL 5 FINISH.
UL1479 ACOUSTICAL SEALANT JOINT SYSTEM EACH SIDE
HEAD OF PARTITION PARALLEL TO METAL DECK FILL VOID AREAS W/ SOUND INSUL., FOR SMOKE PARTITIONS SMOKESTOP ALL VOID AREAS TIGHT TO UNDERSIDE OF STRUCTURAL W/ SAFING
HEAD OF PARTITION PARALLEL TO METAL DECK
HEAD OF PARTITION PARALLEL TO METAL DECK
FIRESTOP W/ U.L. OR W.H.I. APPROVED (1) HR. JOINT FIRESTOP SYSTEM.
DEFLECTION SLIP TRACK (TYPICAL)
FIRESTOP W/ U.L. OR W.H.I. APPROVED (1) HR. JOINT FIRESTOP SYSTEM.
14 GA. STL. PLATE AS REQ'D
HEAD OF PARTITION PARALLEL TO METAL DECK HEAD OF PARTITION PARALLEL TO METAL DECK BOTTOM OF STEEL DECK
BOTTOM OF STEEL DECK
BOTTOM OF STEEL DECK
SEALANT, BOTH SIDES
SEALANT, BOTH SIDES
FIRE RATED SEALANT, BOTH SIDES
HEAD OF PARTITION PERPENDICULAR TO METAL DECK
HEAD OF PARTITION PERPENDICULAR TO METAL DECK
FILL ALL VOID AREAS TIGHT TO UNDERSIDE OF STRUCTURE WITH MINERAL WOOL FIRE SAFING
BOTTOM OF STEEL DECK
HEAD OF PARTITION PERPENDICULAR TO METAL DECK
BOTTOM OF STEEL DECK UL1479 ACOUSTICAL SEALANT JOINT SYSTEM EACH SIDE
BOTTOM OF CONC. SLAB
BOTTOM OF CONC. SLAB
BOTTOM OF CONC. SLAB
SEALANT, BOTH SIDES
FIRE/SMOKE SEALANT, BOTH SIDES
FIRE/SMOKE SEALANT, BOTH SIDES
HEAD OF PARTITION AT CONCRETE SLAB
HEAD OF PARTITION AT CONCRETE SLAB
HEAD OF PARTITION PERPENDICULAR TO METAL DECK
3 1/2" SOUND ATTENUATION BATT INSULATION
HEAD OF PARTITION PERPENDICULAR TO METAL DECK
HEAD OF PARTITION AT CONCRETE SLAB
4 7/8"
EXISTING OR NEW STUCTURE; REFER TO PLAN
6 1/8" 6"
4 7/8"
DEFLECTION SLIP TRACK (TYPICAL)
ACOUSTIC CEILING INSULATION ABOVE ENTIRE CEILING ON ROOM SIDE OF D1 PARTITION TYPES - TYP . FINISHED CEILING MAY OCCUR, REFER TO FINISH SCHEDULE.
FINISHED CEILING MAY OCCUR, REFER TO FINISH SCHEDULE.
METAL STUDS @ 16" O.C.
METAL STUDS @ 16" O.C.
METAL STUDS @ 16" O.C.
FINISHED CEILING MAY OCCUR, REFER TO FINISH SCHEDULE.
FINISHED CEILING, REFER TO FINISH SCHEDULE.
6"
FINISHED CEILING MAY OCCUR, REFER TO FINISH SCHEDULE.
1 LAYER OF 5/8" GYP. BD.
1 LAYER OF 5/8" GYP. BD.
2 LAYER OF 5/8" GYP. BD.
3 1/2" SOUND ATTENTUATION BATT INSULATION MAY OCCUR
3 1/2" SOUND ATTENTUATION BATT INSULATION MAY OCCUR
3 1/2" SOUND ATTENTUATION BATT INSULATION MAY OCCUR
20 GAUGE, METAL STUDS @ 24" O.C. METAL STUDS @ 16" O.C. 1 LAYER OF ACOUSTICALLY ENHANCED 5/8" GYP. BD.
FINISHED CEILING, REFER TO FINISH SCHEDULE. ACOUSTIC INSULATION PER TYPE D1
1 LAYER OF ACOUSTICALLY ENHANCED 5/8" GYP. BD.
METAL STUDS @ 16" O.C. 1 LAYER OF 5/8" GYP. BD.
1 LAYER OF 5/8" GYP. BD.
2 LAYER OF 5/8" GYP. BD.
1 LAYER OF 5/8" GYP. BD.
1 LAYER OF 5/8" GYP. BD.
3 1/2" SOUND ATTENUATION BATT INSULATION
1 LAYER OF 5/8" GYP. BD.
SEALANT, BOTH SIDES
FIRE/SMOKE SEALANT, BOTH SIDES
FIRE/SMOKE SEALANT, BOTH SIDES
SEALANT, BOTH SIDES
UL1479 ACOUSTICAL SEALANT JOINT SYSTEM EACH SIDE
REFER TO FINISH SCHEDULE FOR BASE
REFER TO FINISH SCHEDULE FOR BASE
REFER TO FINISH SCHEDULE FOR BASE
REFER TO FINISH SCHEDULE FOR BASE
REFER TO FINISH SCHEDULE FOR BASE
REFER TO FINISH SCHEDULE FOR BASE
SEALANT
FINISH FLOOR
FINISH FLOOR
FINISH FLOOR
FINISH FLOOR
4 7/8"
A
NON-FIRE RATED, NON-BEARING PARTITION3 5/8" MTL. STUDS W/ 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (4 7/8" WIDE)
A1
NON-FIRE RATED, NON-BEARING PARTITION6" MTL. STUDS W/ 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (7 1/4" WIDE)
A2
NON-FIRE RATED, NON-BEARING PARTITION2 1/2" MTL. STUDS W/ 1/2" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (3 1/2" WIDE)
4 7/8"
4 7/8"
4 7/8"
6 1/8"
B
1 HR. FIRE RATED (UL DESIGN NO. U465) NON-BEARING PARTITION- 3 5/8" MTL. STUDS W/ 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (4 7/8" WIDE)
C
2 HR. FIRE RATED (UL DESIGN NO. U411) NON-BEARING PARTITION- 3 5/8" MTL. STUDS W/ (2) LAYERS 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (6 1/8" WIDE)
B1
1 HR. FIRE RATED (UL DESIGN NO. U465) NON-BEARING PARTITION- 6" MTL. STUDS W/ 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (7 1/4" WIDE)
C1
2 HR. FIRE RATED (UL DESIGN NO. U411) NON-BEARING PARTITION- 6" MTL. STUDS W/ (2) LAYERS 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (8 1/2" WIDE)
C2
FINISH FLOOR
D D1
NON-FIRE RATED, NON-BEARING PARTITION3 5/8" MTL. STUDS W/ 5/8" GYP. BD. EACH SIDE TO 6" ABOVE FINISHED CEILING (4 7/8" WIDE)
E
F
NON-FIRE RATED, ACOUSTIC, NON-BEARING, PARTITION- 3 5/8" MTL. STUDS W/ 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (4 7/8" WIDE) (STC-50 ) (SEE ACOUSTIC DETAILS 4-7 ON A-513 FOR MORE INFO.)
SAME AS ABOVE EXCEPT W/ACOUSTIC INSULATION AND SEALANT AT ALL GAPS AND PENETRATIONS (SEE ACOUSTIC DETAILS 4 & 5 ON A-513 FOR MORE INFO.)
NON-RATED NON-BEARING PARTITION- 3 5/8" MTL. STUDS W/ (2) LAYERS 5/8" GYP. BD. EACH SIDE TO STRUCTURE ABOVE (6 1/8" WIDE) SEAL ALL GAPS AND PENETRATIONS WITH ACOUSTIC SEALANT. (SEE ACOUSTIC DETAILS 4-7 ON A-513 FOR MORE INFO.)
2" WIDE x 14 GAUGE, COLD FORMED PLATES @ 16" O.C. ATTTACHED TO DECK FLUTES
14 GA. STL. PLATE AS REQ'D
14 GA. STL. PLATE AS REQ'D
BOTTOM OF STEEL DECK
BOTTOM OF STEEL DECK
BOTTOM OF STEEL DECK
F1
NON-FIRE RATED FURRING7/8" HAT CHANNELS W/ 5/8" GYP BD. ONE SIDE TO 6" ABOVE CEILING. (1 1/2" WIDE)
F2
NON-FIRE RATED FURRING2 1/2" MTL. STUDS W/ 5/8" GYP BD. ONE SIDE TO 6" ABOVE CEILING. (3 1/8" WIDE)
14 GA. STL. PLATE AS REQ'D
REFER TO STRUCTURAL FOR SIZE & SPACING OF STAGGERED WALL SUPPORT ANGLES
FIRE RATED JOINT SYSTEM MATCHING HOURLY WALL RATINGS 14 GA. STL. PLATE AS REQ'D
NON-FIRE RATED FURRING3 5/8" MTL. STUDS W/ 5/8" GYP BD. ONE SIDE TO 6" ABOVE CEILING. (4 1/4" WIDE)
HEAD OF PARTITION PARALLEL TO METAL DECK
COMPRESSIBLE MATERIAL
FIRE RATED JOINT SYSTEM MATCHING HOURLY WALL RATINGS DEFLECTION TRACK - TYP.
DEFLECTION TRACK - TYP.
DEFLECTION TRACK - TYP.
HEAD OF PARTITION PARALLEL TO METAL DECK PARTITION HEAD PARALLEL TO DECK
PARTITION HEAD PARALLEL TO DECK
PARTITION HEAD PARALLEL TO DECK
BOTTOM OF STEEL DECK
SHAFT SIDE BOTTOM OF STEEL DECK
BOTTOM OF STEEL DECK
BOTTOM OF STEEL DECK
DEFLECTION TRACK - TYP.
DEFLECTION TRACK - TYP.
DEFLECTION TRACK - TYP.
HEAD OF PARTITION PERPENDICULAR TO METAL DECK FINISHED CEILING, REFER TO FINISH SCHEDULE.
REFER TO STRUCTURAL FOR SIZE & SPACING OF STAGGERED WALL SUPPORT ANGLES
EDGE OF OF CONC. SLAB 3 - 5/8" MTL STUDS @ 16" O.C.
3 - 5/8" MTL STUDS @ 16" O.C.
5/8" GWB. W/ACOUSTIC INSULATION (SEAL ALL GAPS & PENETRATIONS)
5/8" GWB. W/ACOUSTIC INSULATION (SEAL ALL GAPS & PENETRATIONS)
STEEL ANGLE BRACING ABOVE GLASS PARTITIONS
STEEL ANGLE BRACING ABOVE GLASS PARTITIONS
WOOD BLOCKING SHOWN MUST BE FIRE RETARDANT
WOOD BLOCKING SHOWN MUST BE FIRE RETARDANT
3 - 5/8" MTL STUDS @ 16" O.C. 5/8" GWB. W/ACOUSTIC INSULATION PARTITION TYPE G2 ONLY PROVIDE CONT. HEADER ABOVE GLASS PARTITIONS
ALIGN
PLYWOOD BLOCKING SHOWN MUST BE FIRE RETARDANT 2 1/2"
CEILING LINE
CEILING LINE
CEILING LINE
GLAZING CHANNEL, ALLOW SPACE FOR GLASS SETTING. (MINIMIZE HEIGHT)
REVEAL AT HEAD & JAMBS - TYP.
DOUBLE HEAD - STAGGER JOINTS AT WALL CORNERS
HEAD OF PARTITION AT CONCRETE SLAB
Checker
GLASS TYPE 4 - SEE SPECS
Checked by:
GLASS TYPE 3 - SEE SPECS
SEE I-DWGS FOR FINISH FLOOR INFO.
Murphy USA
FINISHED CEILING MAY OCCUR, REFER TO FINISH SCHEDULE. REFER TO STRUCTURAL FOR GROUT AND REINFORCEMENT INFORMATION
C-H STUDS FULL HEIGHT AT 24" O.C. 1 LAYER OF 1" GYP. BD. LINER PANEL U.L. APPROVED 3" MINERAL WOOL SOUND ATTENUATION BATT INSULATION 2 LAYERS OF 5/8" GYP. BD.
SHAFT SIDE
SEALANT, BOTH SIDES
REFER TO FINISH SCHEDULE FOR BASE
REFER TO FINISH SCHEDULE FOR WALL BASE
FINISH FLOOR
FIRE RATED JOINT SYSTEM MATCHING HOURLY WALL RATINGS
2"
EXISTING CONCRETE SLAB WITH WELD MESH 1" BELOW SURFACE
G1
PROPRIETARY GLASS PARTITION SYSTEM GLASS TYPE 1, W/O GWB/INSUL. ABV. 2" FRAME W/REVEAL AT HEAD & JAMBS
C.M.U. W/ HORIZONTAL REINF. @ 16" O.C. VERTICALLY; REFER TO STRUCT. FOR VERT. REINF.
G2
PROPRIETARY GLASS PARTITION SYSTEM GLASS TYPE 2, W/ GWB/INSUL. ABV. 2" FRAME W/REVEAL AT HEAD & JAMBS
G3
FRAMELESS GLASS PARTITION (BUTT-GLAZED, EXPOSED CHANNELS)
G4
FRAMELESS GLASS PARTITION (BUTT-GLAZED, NO EXPOSED CHANNELS)
H
PARTIAL HEIGHT PARTITION 3 5/8" MTL. STUDS @ 16" O.C. W/ 5/8" GWB. EACH SIDE (4 7/8" WIDE)
REFER TO FINISH SCHEDULE FOR BASE FINISH FLOOR
VARIES
4 7/8"
J J1
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
FINISH FLOOR SAW CUT EXISTING SLAB 3/4" DEEP MAX. TO RECESS GLASS W/SETTING BLOCK. SEAL GAPS WITH FLOOR SETTING COMPOUND
EXPOSED SHOE (MINIMIZE HEIGHT)
MM
HEAD OF PARTITION PERPENDICULAR TO METAL DECK
SECURE TO FRAMING PER MANUF.
CLEAR SAFETY GLASS (VARIES PER TYPE BELOW)
COMPRESSIBLE MATERIAL
FIRE RATED JOINT SYSTEM MATCHING HOURLY WALL RATINGS
GLAZING CHANNEL ABOVE CEILING, ALLOW SPACE FOR GLASS SETTING
SEE I-DWGS FOR FINISH FLOOR INFO.
Drawn by:
CORNER PROTECTION GWB BEAD
SEE INTERIOR ELEVATION
LIGHT GA. DIAGONAL BRACING
2 HR. FIRE RATED (UL DESIGN NO. U415 SYSTEM B) NON-ACOUSTIC, NONBEARING SHAFT WALL - 2 1/2" MTL. C-H STUDS W/ (2) LAYER OF 5/8" GYP. BD. ON FINISH SIDE & 1" GYP. LINER PANELS ON SHAFT SIDE (3 3/4 WIDE)
2 HR. FIRE RATED (UL DESIGN NO. U415 SYSTEM B) NON-ACOUSTIC, NONBEARING SHAFT WALL- 4" MTL. C-H STUDS W/ (2) LAYER OF 5/8" GYP. BD. ON FINISH SIDE & 1" GYP. LINER PANELS ON SHAFT SIDE (5 1/4" WIDE)
K
NON-FIRE RATED, NON-BEARING CMU PARTITION- 8" LIGHTWEIGHT CONCRETE BLOCK. (7 5/8" WIDE)
K1
NON-FIRE RATED, NON-BEARING CMU PARTITION- 6" LIGHTWEIGHT CONCRETE BLOCK. (5 5/8" WIDE)
K2
2-HR. FIRE RATED U.L. U905, NON-BEARING CMU PARTITION- 8" CONCRETE BLOCK. FULLY GROUTED (7 5/8" WIDE) NOTE: CMU TO MATCH EXISTING CMU TYPE AND DIMENSION. TOOTH-IN NEW CMU INTO EXISTING CMU. AVOID CUTTING EXISTING CMU IF AT ALL POSSIBLE.
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
PARTITION TYPES
CD
A-600
12/1/2015 4:25:53 PM
DOOR No
WIDTH
001 003A 003B 004 007B 010 011 S1.0
4' - 0" 6' - 0" 3' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
DOOR TYPE
HEIGHT THICKNESS 7' - 0" 7' - 2" 7' - 2" 7' - 2" 7' - 2" 7' - 2" 7' - 2" 8' - 10"
101 103 104 105 106 109 110 111A 111B 111C 112 112A 112B 112C 112D 114A 115 116 117A 117B 118 120 121 122 123 124 125 128 129 130 131 132 133 133A 133B 133C 134A 134B 135A 135B 137 137A 137B 137C 137D 137E 138 140 141 142 143 144 145A 145B 145C 145D 146A 146B 147 148 149 150 151 152 153 154 155 156 157A 157B 157C 157D 159 160 S1.1 S2.1 S3.1 S4.1
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 6" 3' - 6" 3' - 9" 8' - 0" 6' - 0" 7' - 5 1/2" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 6" 3' - 6" 3' - 0" 3' - 0" 3' - 0" 6' - 4" 6' - 4" 8' - 0" 12' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 6" 3' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 5' - 11 1/2" 5' - 11 1/2" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 11" 9' - 0" 9' - 2" 8' - 9" 8' - 9" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 9' - 0" 9' - 2" 8' - 10" 8' - 10" 8' - 10" 9' - 2" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 8" 8' - 8" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10"
200 203 204 205 206 209 210 211 219 221 224 225 226 227 228 229 230 231 232 233A 233B 234 237 238 240 241 242 243 244 245 246 247 248 249 250
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 8" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 7' - 10" 7' - 10" 8' - 10" 7' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10"
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
DOOR MATERIAL
FRAME FRAME TYPE MATERIAL
JAMB DETAIL
DOOR AND FRAME SCHEDULE HARDWARE SET
FIRE RATING
COMMENTS 13, EXISTING DOOR
F A F A A A
HM HM HM HM HM HM
2 1 2 1 1 1
WD WD WD WD WD WD WD GL GL GL AL/GL GL GL AL/GL AL/GL WD GL WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD GL WD WD WD WD WD
HM HM HM HM HM HM
EX EX EX EX
EX EX EX EX ETR EX EX
J5 J4 J5 J5 J5 J5
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 0 1/2" 0' - 0 1/2"
A A A A A A A C C C
0' - 0 1/2" 0' - 0 1/2" 0' - 2 1/4" 0' - 2 1/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 2" 0' - 2"
C2 C2 D2 D2 A C A A A A A A A A A A A A A A A C A A A A A
0' - 1 3/4" 0' - 2 1/4" 0' - 2 1/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 2 1/4" 0' - 2 1/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 0 1/2" 0' - 2 1/4" 0' - 2 1/4" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
C3 D2 D2 C C A A A A A C A2 A2 D2 D2 A A A A A A A A A A A A C2 C2 D2 D2 C A B B B B
AL/GL AL/GL AL/GL AL/GL GL GL WD WD WD WD WD GL WD WD AL/GL AL/GL WD WD WD WD WD WD WD WD WD WD WD WD GL GL AL/GL AL/GL GL WD WD/GL WD/GL WD/GL WD/GL
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
A A A A A A A A A A A A A A A A A A A A A A
WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD
3 3 3 3 3 3 1 4 3 3 3 EX EX 1
AL AL AL AL AL AL AL AL AL AL AL EX EX AL
J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J3 J3 J1
A A A A A A A A A A A A
WD WD WD WD WD WD WD WD WD WD WD WD
1 3 3 3 1 3 3 1 4 3 1 3
AL AL AL AL AL AL AL AL AL AL AL AL
J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1
EX EX
2 2 1
AL AL AL
90 MIN 90 MIN
13 13, EXISTING DOOR
J3 J3 J3 J3
1 1 1 1
J3 J3
1 1 13 13 13 13, REVOLVING DOOR 6, 13 6 6, 13, 16
J1
4 4 4 4 3 1 1 3 3 3 3 3 3 3 4
AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL
J2 J2 J2 J2 J1 J1 J1 J1 J1 J1 J1 J1 J1 J2 J2
1 1 1 1 1
AL AL AL AL AL
J1 J1 J1 J1 J1
5 5 5 5 5 13 5 5 5 5 5 5 5 5 13
6, 14 6, 14 13, REVOLVING DOOR 6 6, 13, 16 6 6 6, 16
2 2
AL AL
1 1 4 3 3
AL AL AL AL AL
J1 J1 J1 J1 J1
2 2 2 2 1 1 3 3 1 1 3 3 4 4 4 4
AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL
J1 J1
2 2
AL AL
1 EX EX EX EX
AL EX EX EX EX
J1 J3 J3 J3 J3
EX
EX
J3
1
EX EX
EX EX ETR EX EX
J3 J3
1 1
J3 J3
1 1 5, 9 5 5 5 5 5 5 13 5 5 5 5 1, 13 1, 13
EX EX
13 5, 13 5 5 13 5, 6, 14 5, 6, 14 6 6
J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J2 J2
5 5 5 5 5 5 5 5 5 6 6 6, 14 6, 14 13 90 MIN 90 MIN 90 MIN 90 MIN
1 1 1, 13 1, 13
13, EXISTING DOOR 5 5 5 5 5 5 13 5 5
DOOR TYPE
HEIGHT THICKNESS
DOOR MATERIAL
DOOR No
WIDTH
251 253 S1.2 S2.2 S3.2 S4.2
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10"
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
A A B B B B
WD WD WD/GL WD/GL WD/GL WD/GL
303 304 305 306 309 310 311 317 319 320 321 322 324 325 326 327 328 329 330 331 332 333 334 335 337 338 339 340 341 342 343 344 345 346 348 350 351 353 S1.3 S2.3 S3.3 S4.3
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 8" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10"
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A B B B B
WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD/GL WD/GL WD/GL WD/GL
403 404 405 406 409 410 411 413 414 415 416 417 418 419 420 421 423 424 425 426 426A 427 428 429 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449A 449B 450 451 453B 456 458A 458B 459 460 461 462 463 465 466 467 468B 468D 469 470 472 481 482 483 484 S1.4 S2.4 S3.4 S4.4
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 2" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 1 3/4" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 3" 6' - 3" 6' - 3" 6' - 3" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 8" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 9' - 0" 8' - 10" 9' - 0" 8' - 10" 9' - 0" 9' - 0" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 7' - 0" 8' - 10" 8' - 10" 9' - 0" 9' - 0" 8' - 10" 9' - 0" 9' - 0" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 8' - 10" 8' - 10" 8' - 10" 8' - 10"
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 0 1/2" 0' - 0 1/2" 0' - 0 1/2" 0' - 1 3/4" 0' - 0 1/2" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
A A A A A A A A A A A A A C C A A A A C C C C A C C A A C A A A A A A A A A A A A A C C
WD WD WD WD WD WD WD WD WD WD WD WD WD GL GL WD WD WD WD GL GL GL GL WD GL GL WD WD GL WD WD WD WD WD WD WD WD WD WD WD WD WD GL GL
A A EX EX A
WD WD EX EX WD
0' - 1 3/4"
0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 0 1/2" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 1' - 6" 1' - 6" 1' - 6" 1' - 6" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4" 0' - 1 3/4"
A EX A A A A A C A A A H H H H B B B B
WD EX WD WD WD WD WD GL WD WD WD PRE PRE PRE PRE WD/GL WD/GL WD/GL WD/GL
FRAME FRAME TYPE MATERIAL
JAMB DETAIL
HARDWARE SET
FIRE RATING
COMMENTS
3 3 EX EX EX EX
AL AL EX EX EX EX
J1 J1 J3 J3 J3 J3
EX EX
J3 J3
1 1
EX EX
EX EX ETR EX EX
J3 J3
4 3 3 3 3 3 4 1 1 3 4 3 3 3 3 3 3 3 3 3 1 3 3 3 1 3 3 3 3 3 3 EX EX EX EX
AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL EX EX EX EX
J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J1 J3 J3 J3 J3
1 1 5, 9 5 5 5 5 5 5 5 5 13 5 5 5 5 5 5 5 5 5 5 5
EX EX
EX EX ETR EX EX
J3 J3
1 1
J3 J3
4 3 3 3 3 1
AL AL AL AL AL AL
J1 J1 J1 J1 J1 J1
4 1 3 3
AL AL AL AL
J1 J1 J1 J1
1 1 5, 9 5 5 5 5 5 13 13 13 5 5, 23 5 5
EX EX
90 MIN 90 MIN 90 MIN 90 MIN
90 MIN 90 MIN 90 MIN 90 MIN
5 5 1 1 1 1
GENERAL DOOR SCHEDULE NOTES 1.
2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12.
13. 14.
5 5 5 13 5 5 5 5 5 5 1 1 1 1
SCHEDULE ABBREVIATIONS NOTE: ABBREVIATIONS BELOW ARE RELATIVE TO THE DOOR SCHEDULE. PROJECT STANDARD ABBREVIATIONS ARE SHOWN ON G-001 HM AL GL WD MTL EX PRE
AL
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16.
J1 7, 13
3 3
AL AL
J1 J1
3 3 3 3 3 3 4 3 4 3 3 3 1
AL AL AL AL AL AL AL AL AL AL AL AL AL
J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J1 J1 J1
1 1
AL AL
J1 J1
1
AL
J1
WD
J8 J7
1 3 4 3
WD AL AL AL AL
J7 J1 J1 J1 J1
5 5 5 13
3 3 1
AL AL AL
EX EX EX EX
EX EX EX EX
J2 J2 J1 J10 J10 J10 J10 J3 J3 J3 J3
5 5 5 6 6 6 6 1 1 1 1
NEW DOOR IN EXISTING FRAME NEW DOOR AND FRAME IN EXISTING OPENING REMOVE AND REPLACE ALL EXPOSED BRASS DOOR HARDWARE. EXISTING DOOR TO BE RELOCATED PER PLANS ACOUSTICAL SEAL (SEE DOOR SEAL DETAIL ON A-615) SMOKE EVACUATION ACTIVATED NOT USED NOT USED WOOD DOOR TO MATCH WOOD AT OVAL ENTRY MILLWORK NOT USED NOT USED NOT USED CARD READER PER HARDWARE SCHEDULE PANIC BAR EGRESS FUNCTION HARDWARE REQUIRED. NOT USED ADA AUTOMATIC OPENER - PUSH BUTTON CONTROL TO BE INTEGRATED WITH CARD READER PANEL TO REPLACE ACCESS CONTROLS CUT INTO EXISTING STONE PANEL. INCLUDE COST OF CUTTING STONE OPENING TO ACCOMMODATE DOOR CONTROLS WHERE THEY OCCUR.
5 5 13 5 5 5 5 5 5 5 5 5 5 5 5 13 13 13 13, EXISTING DOOR 13 13 3 3 3 3, 4 3, 13
90 MIN 90 MIN 90 MIN 90 MIN
Murphy USA
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky POCKET DETAIL SEE
J10 / A-615 SEE SCHEDULE
SCHED. D.O.
SCHED. D.O.
3'-0" U.N.O. ON PLAN
SCHED. D.O.
SCHED. D.O.
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
VARIES - SEE PLAN
X
MM
3' - 10"
5" 4"
DOOR AND FRAME SCHEDULE
SCHED. D.O.
X
SEE SCHEDULE
2' - 0"
DIVIDE EQUALLY
Drawn by:
HOLLOW METAL ALUMINUM GLASS WOOD - SOLID CORE METAL EXISTING (TO REMAIN OR REMOVE/REINSTALL) PREFINISHED PER MANUF.
SCHEDULE NOTES AND COMMENTS
13 1
CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND NOTIFY ARCHITECT OF ANY DISCREPENCIES BETWEEN DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING WITH ANY WORK. SEE ELEVATIONS AND PARTITION TYPES FOR GLASS TYPES AS NOTED IN GLAZING SCHEDULE SPECIFICATIONS REFER TO SPECIFICATIONS FOR HARDWARE SCHEDULE. SEE FINISH LEGEND FOR DOOR AND FRAME FINISHES. SEE SHEET A-615 FOR JAMB DETAILS. ALL GLASS DOORS, DOORS WITH GLASS AND GLASS DIRECTLY ADJACENT TO DOORS MUST BE SAFETY TYPE GLAZING (TEMPERED OR LAMINATED) ALL EXTERIOR FRAMESTO BE THERMALLY ISOLATED WITH FULL PERIMETER INTEGRAL WEATHER SEALS U.O.N. ALL HARDWARE FINISH TO BE SATIN CHROME OR STAINLESS STEEL UNLESS OTHERWISE NOTED ALL CARD READERS TO BE STORE ROOM FUNCTION U.O.N. ALL SECURE DOORS MUST BE ALLOWED TO EGRESS DURING FIRE ALARM ACTIVATION. ALL EXTERIOR DOORS AND GLAZING TO BE LATERALLY BRACED AT HEAD WITH STEEL ANGLES TO STRUCTURAL DECK U.O.N. DOOR SIZES SHOWN ARE REVIT MODEL GENERATED AND MAY VARY FROM ACTUAL DOOR SIZES REQUIRED. DOOR SIZES TO BE VERIFIED AND APPROVED BY ARCHITECT DURRING SUBMITTAL PROCESS. ALL WOOD DOOR AND FRAMES IN EXECUTIVE SUITE AREA (SOUTH PORTION OF 4TH FLOOR) ARE TO MATCH EXISTING ADJACENT CUSTOM WOOD DOORS. SEE SPECS FOR ALTERNATE 3. CONCRETE SLAB REMOVAL REQUIRED TO ACCOMODATE FRAMELESS GLASS AND REVOLVING DOOR TYPES.
5
Checked by:
Checker
DOOR AND FRAME SCHEDULE
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
FINISH FLOOR 0'-0"
A
A2
B
C
C2
C3
D
D2
H
FLUSH DOOR
DOUBLE DOOR
FLUSH DOOR W/VISION LIGHT
GLASS DOOR W/PATCH FITTINGS
DOUBLE GLASS DOOR W/PATCH FITTINGS
AUTOMATIC ALL GLASS SLIDING DOORS
SINGLE-LITE DOOR
DOUBLE SINGLE-LITE DOOR
HORIZONTAL SLIDING ACCORDIAN DOOR
DOOR TYPES: SEE DOOR SCHEDULE FOR DOOR SIZE
1 SINGLE DOOR
2 DOUBLE DOOR
3
4
DOOR W/SIDELITE
DOOR W/BUT-GLAZED INTERIOR STOREFRONT
FRAME TYPES: SEE DOOR DETAILS FOR FRAME INFORMATION
CD
A-610
12/1/2015 4:26:06 PM
SECONDARY
2 SELF ADHESIVE SILICONE OR NEOPRENE SEALS SHOWN IN A NONCOMPRESSED POSITION
CMU - SEE PARTITION TYPES
2"
ALIGN
1/2"
H.M. FRAME W/REVEAL TO MATCH EXISTING
SOLID CORE WOOD DOOR (TYP.)
+/10" HIGH CMU HEADER TO MATCH EXISTING CONT. SEAL EA. SIDE
1 1/2"
1/2" 1 1/2"
CONT. GWB BEAD
STRIKE JAMB
HINGE JAMB FOAM SEAL
H.M. FRAME W/REVEAL TO MATCH EXISTING AT CMU CONDITIONS - FILL W/GROUT
NEW DOOR - SEE SCHEDULE
NEW DOOR - SEE SCHEDULE
2"
GWB BEAD
CEILING AT HEAD CONDITION
EXISTING FRAME TO BE RETROFITED WITH NEW DOOR AND HARDWARE
1/2"
1/2"
CEILING AT HEAD CONDITION
ALL INTERIOR FRAMES TO HAVE REVEAL TO MATCH EXISTING U.O.N.
ALIGN
MATCHING ALUM . COVER PLATES BY SAME MANUF.
4 7/8"
ALIGN
1/2"
CEILING AT HEAD CONDITION
ALIGN
2"
4 7/8"
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
(HEAD SIMILAR)
SOLID CORE
NEW DOOR - SEE SCHEDULE
ACOUSTIC SEAL
J1
ALUM. JAMB - TYP.
J2
3" = 1'-0"
ALUM. DBL. JAMB
J3
3" = 1'-0"
JAMB AT EXIST. FRAME
J4
3" = 1'-0"
H.M. JAMB AT GWB
J5
3" = 1'-0"
1/4" MAX.
H.M. JAMB AT CMU
AUTOMATIC DOOR BOTTOM
3" = 1'-0"
ASTRAGAL SEAL
SEE 7 / A-502 FOR EXTERIOR WALL ASSEMBLY
MATCH EXIST.
CLEAR SILICONE SEALANT (ULTRAQUICK DRYING TYPE FOR GLASS LAMINATES) MINIMIZE JOINT
MATCH EXIST.
Q
2"
FRAMELESS GLASS PARTITION
MATCH EXISTING ADJACENT REVEAL GWB BEAD
T
NATIONAL GUARD
5050
109N
423N
PEMKO
S 88
355CS
434A
REESE
797
MORTISE
371
ZERO
DB 043 1840
369
NOTES: 1. INSTALL DOOR IN FRAME WITH 1/8" MAX. TOLERANCE @ HEAD, HINGE & STRIKE JAMB.
ARCH. FINISH GRADE VENEER PLYWOOD TO MATCH EXISTING
2. PERIMETER SEAL SHALL ALWAYS BE MIN. SEMI COMPRESSED WITH DOOR CLOSED.
SEALANT W/ BACKER ROD
3. IF TOLERANCE @ PERIMETER IS GREATER THAN 1/8" & DOOR CANNOT BE ADJUSTED, REPLACE WITH 1/2" SEAL INSTEAD OF 1/4" SEAL.
FINISH CEILING - SEE RCP & FINISH SCHEDULE
33
4. ALL GAPS @ INTERSECTION OF ASTRAGAL & AUTOMATIC DOOR BOTTOM SHALL BE SEALED. 5. FOR DOUBLE INTERCONNECTING DOORS PROVIDE PERIMETER SEALS AND AUTOMATIC DOOR BOTTOMS ON BOTH DOORS.
CENTER OF PARTITION AND GLASS
FRAMELESS GLASS PARTITION
9
EXISTING MTL. STUD TO REMAIN
ACOUSTIC DOOR SEAL
PERIMETER ASTRAGAL
ULTRA
WOOD BLOCKING - FIRE RETARDANT
MAINTAIN EXISTING REVEAL BETWEEN NEW AND OLD CONSTRUCTION
CLEAR SILICONE SEALANT (ULTRA-QUICK DRYING TYPE FOR GLASS LAMINATES) MINIMIZE JOINT
CENTER OF PARTITION AND GLASS
AUTOMATIC DOOR BOTTOM
MANUFACTURER
8
PATIO ENCLOSURE DOOR - HEAD
DOOR SEAL DETAILS 3" = 1'-0"
3" = 1'-0"
WOOD FRAME AND DOOR TO MATCH EXISTING WOOD DOORS
QQ BACKER ROD AND SEALANT EXISTING BEAM
DOOR SWEEP 1/2" RIGID INSULATION
WOOD JAMBS AT EXEC. STE.
THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB. 3/8"
J7
MAINTAIN EXISTING REVEAL BETWEEN NEW AND OLD CONSTRUCTION
3" = 1'-0" EXISTING WOOD MILLWORK AND RCESSED DOOR ASSEMBLY
1/8" / 1'-0"
01 FIRST FLOOR 0' - 0"
EXISTING FLOOR
SEALANT W/ BACKER ROD NON-POROUS SHIM/BLOCKING BED OF SEALANT
RETROFIT JAMB AT EXEC. STE.
J8
3" = 1'-0"
2 LAYERS OF 5/8" GYP BD. ON 3-5/8" LIGHT GA. FRAMING, EACH SIDE
NEW CAST IN PLACE CONCRETE RETAINING WALL AND FOUNDATION. SEE STRUCT.
7 4
PATIO ENCLOSURE DOOR - SILL 3" = 1'-0" PROVIDE STEEL PLATE ATTACHMENT PER ACCORDIAN DOOR MANUF.
34
1
BATT INSULATION
FINISH CEILING - SEE RCP & FINISH SCHEDULE
FINISH CEILING - SEE RCP & FINISH SCHEDULE SILICONE SEALANT
STEEL ANGLE - SEE STRUCT. SEALANT W/ BACKER ROD
EXISTING STUCCO SOFFIT TO REMAIN. PATCH AS REQD.
SEALANT W/ BACKER ROD FINISH CEILING - SEE RCP & FINISH SCHEDULE
FINISH CEILING - SEE RCP & FINISH SCHEDULE
MANUAL ROLLER SHADE
ENTRY DOOR HEAD - NORTH VESTIBULE 3" = 1'-0"
GYP. BOARD CEILING
ACT CEILING
SEALANT W/ BACKER ROD
SEALANT W/ BACKER ROD
6
ALIGN
SEE RCP FOR CEILING HEIGHT
WOOD BLOCKING - FIRE RETARDANT
SEE RCP FOR CEILING HEIGHT
EXTRUDED ALUM. ACT EDGE TRIM
ENTRY DOOR HEAD - SOUTH VESTIBULE
5
3" = 1'-0"
4
H10
ACCORDIAN DOOR HEAD 3" = 1'-0"
Murphy USA
EXTERIOR DOOR - HEAD 3" = 1'-0"
34
Checker
1' - 6"
FINISHED FLOOR - SEE FLOOR FINISH PLANS
BACKER ROD AND SEALANT
BACKER ROD AND SEALANT
THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON NEW CONCRETE SLAB.
STAINLESS STEEL ENTRANCE FLOOR MAT AND FRAME WN 1:25 MAX. SLOPE DO
01 FIRST FLOOR 0' - 0" NON-POROUS SHIM/BLOCKING
NON-POROUS SHIM/BLOCKING
6"
BED OF SEALANT
08.002
BED OF SEALANT
EXPANSION JOINT
Author
1/2" RIGID INSULATION
NON-POROUS SHIM/BLOCKING
NON METALLIC NON SHRINK GROUT
ENTRY DOOR SILL - NORTH VESTIBULE 3" = 1'-0"
DOOR HEAD AND JAMB DETAILS
BED OF SEALANT FINISHED FLOOR - SEE FLOOR FINISH PLANS
3
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
3/4"
3/4"
1:25 MAX. SLOPE DOWN
5/8"
1:25 MAX. SLOPE DOWN
SEALANT W/ BACKER ROD
CLEAR
NON METALLIC NON SHRINK GROUT
THRESHOLD W/ THERMAL BREAK NON METALLIC NON SHRINK GROUT THERMALIZED GRANITE TILE ON THINSET TILE MASTIC SETTING BED ON EXISTING CONCRETE SLAB. 3/8" / 1'-0"
1' - 6"
Checked by:
THRESHOLD W/ THERMAL BREAK
DOOR SWEEP
Westlake Reed Leskosky
SSG ALUMINUM CURTAIN WALL SYSTEM
SSG ALUMINUM CURTAIN WALL SYSTEM THRESHOLD W/ THERMAL BREAK
CLEAR
DOOR SWEEP
DOOR SWEEP
SEALANT W/ BACKER ROD
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
1 4
2
ENTRY DOOR SILL SOUTH VESTIBULE 3" = 1'-0"
1
EXTERIOR DOOR - SILL 3" = 1'-0"
CD J10
ACCORDIAN DOOR JAMB 3" = 1'-0"
A-615
12/1/2015 4:43:55 PM
PRIMARY FINISH ROOM SCHEDULE Room No 00 BASEMENT 001 002 003 004 005 007 008 009 010 011 012 E-3 S-01
Room Name RECEIVING MECH EQUIPMENT ROOM PRINT ROOM MAIL ROOM BUILDING OPERATIONS/ MECHANICS MAIN ELECTRICAL CORRIDOR ELEV. EQUIP. STORAGE FIBER TELECOM TOILET SERVICE ELEVATOR STAIRS
Drawn by:
Author
Checked by:
Checker
OA-E1 OA-S1 OA-W1 S-1 S-2 S-3 S-4
North
West
Millwork Finish Vertical Horizontal Transaction
Ceiling Finish
Comments
CONC-1 CONC-1 CONC-1 CONC-1 CONC-1
RB-1 RB-1 RB-1 RB-1 RB-1
IPT-2A IPT-2A IPT-2 IPT-2 IPT-2
IPT-2A IPT-2A IPT-2 IPT-2 IPT-2
IPT-2A IPT-2A IPT-2 IPT-2 IPT-2
IPT-2A IPT-2A IPT-2 IPT-2 IPT-2
IPT-1 IPT-1 ACT-1 ACT-1 ACT-1
------
------
------
------
CONC-1 CONC-1 CONC-1 CONC-1 CONC-1 CONC-1 RF-1 RF-1
RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 ---
IPT-2A IPT-2A IPT-2A IPT-2 IPT-2A IPT-2A -IPT-2
IPT-2A IPT-2A IPT-2A IPT-2 IPT-2A IPT-2A -IPT-2
IPT-2A IPT-2A IPT-2A IPT-2 IPT-2A IPT-2A -IPT-2
IPT-2A IPT-2A IPT-2A IPT-2 IPT-2A IPT-2A -IPT-2
IPT-1 IPT-1 IPT-1 ACT-1 IPT-1 IPT-1 -AF-1
---------
---------
---------
---------
CONC-1 CONC-1 CONC-1 T-3 T-3 CONC-1 CONC-1 T-3 T-3 TERR-1 TERR-1 NIC TERR-1 T-3 CPT-1 CPT-1 CPT-1 CPT-2 CPT-2 VCT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-3 CPT-1 VCT-1 VCT-1 CONC-1 RF-1 T-2 TERR-1 WOM-1 CPT-1 VCT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-1 VCT-1 CPT-2 CPT-2 CPT-2 VCT-3 CPT-2 CPT-2 CPT-1 CPT-1 CPT-1 CPT-1 STONE PAVING STONE PAVING CPT-2 VCT-1 CPT-2 TERR-1 TERR-1 CPT-1
RB-1 RB-1 RB-1 T-3 T-3 RB-1 RB-1 T-3 T-3 TERR-1 TERR-1 NIC TERR-1 T-3 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RF-1 T-2 TERR-1 TERR-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 --RB-1 RB-1 RB-1 TERR-1 TERR-1 --
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 NIC IPT-2 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2A IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 NIC IPT-2 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2A IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 NIC IPT-2 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A T-4 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 NIC IPT-2 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A T-4 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
---PL-1 PL-1 --PL-1 PL-1 SSM-1 SSM-1 NIC SSM-1 PL-1 -------------PL-1 ----PL-1 -SSM-1 -------------PL-1 ---------------
---SSM-2 SSM-2 --SSM-2 SSM-2 SSM-1 SSM-1 NIC SSM-1 SSM-2 -------------SSM-1 ----SSM-1 -SSM-1 -------------SSM-1 ---------------
---------SSM-1 SSM-1 NIC SSM-1 ---------------------SSM-1 -----------------------------
ELEVATOR 2
CPT-1
--
--
--
--
--
--
--
--
--
OPEN WORKSTATION AREA OPEN WORKSTATION AREA OPEN WORKSTATION AREA NW STAIR 1 NE STAIR 2 SW STAIR 3 SE STAIR 4
CPT-2 CPT-2 CPT-2 RF-1 RF-1 RF-1 RF-1
RB-1 RB-1 RB-1 -----
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
ACT-2, IPT-1 ACT-2, IPT-1 ACT-2, IPT-1 AF-1 AF-1 AF-1 AF-1
--------
--------
--------
--------------------------------T-5 AT BACKSPLASH, SEE ELEVATIONS -----PAINT ALL EXPOSED CEILING AREAS, IPT-1 --PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 -------------------REFER TO SECTION 140120.71 - ELEVATOR REHABILITION FOR CAB FINISHES, INTERIOR OF ELEVATOR SHAFT TO BE PAINTED IPT-5 (BLACK) REFER TO SECTION 140120.71 - ELEVATOR REHABILITION FOR CAB FINISHES, INTERIOR OF ELEVATOR SHAFT TO BE PAINTED IPT-5 (BLACK) PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 -----
CPT-2 CPT-2 CONC-1 CONC-1 CONC-1 T-3 T-3 CONC-1 CONC-1 T-3 T-3 CPT-1 CPT-2 CPT-2 CPT-2 CPT-2 VCT-3 T-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-2 CPT-1 CPT-2 CPT-2 CPT-2 VCT-2 VCT-3 VCT-2 VCT-2 VCT-1 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-1 CPT-2 CPT-2 VCT-2 CPT-1 CPT-2 VCT-1 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2
RB-1 RB-1 RB-1 RB-1 RB-1 T-3 T-3 RB-1 RB-1 T-3 T-3 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 T-2 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2
AF-1,IPT-1 IPT-1 IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A AF-1, IPT-1 AF-1, IPT-1 AF-1, IPT-1 AF-1, IPT-1 AF-1, IPT-1 ACT-1 ACT-1 ACT-2, IPT-1 ACT-2 AF-1, IPT-1 ACT-2 AF-1, IPT-1 ACT-2, IPT-1 ACT-2 ACT-2 ACT-2 ACT-2 IPT-1 ACT-2 ACT-2 ACT-2 ACT-2 IPT-1 ACT-1 IPT-1 IPT-1 IPT-1 ACT-2, IPT-1 AF-1, IPT-1 ACT-2 ACT-2 ACT-2 ACT-1 ACT-2 ACT-2 IPT-1 ACT-2 ACT-2 ACT-1 ACT-2 ACT-2 AF-1, IPT-1 ACT-2 ACT-2, IPT-1 ACT-2, IPT-1 ACT-2, IPT-1 ACT-2, IPT-1
-----PL-1 PL-1 --PL-1 PL-1 --WP-1 WP-1 WP-1 PL-1 PL-1 ----------------PL-1 ----WP-1 -------------------
-----SSM-2 SSM-2 --SSM-2 SSM-2 --SSM-2 SSM-2 SSM-2 SSM-1 SSM-1 ----------------SSM-1 ----SSM-2 -------------------
-----------------------------------------------------------
-----------DRAPERY (D-1) AT PERIMETER. -----T-5 AT BACKSPLASH, SEE ELEVATIONS PAINT ALL EXPOSED CEILING AREAS, IPT-1 ----PAINT ALL EXPOSED CEILING AREAS, IPT-1 ---------EXISTING RAISED ACCESS FLOORING TO REMAIN. -EXISTING RAISED ACCESS FLOORING TO REMAIN. EXISTING RAISED ACCESS FLOORING TO REMAIN. -PAINT ALL EXPOSED CEILING AREAS, IPT-1 ---------------PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1
01 FIRST FLOOR 101 JAN. 102 ELEC. 103 MECH 104 MENS TOILET 105 WOMENS TOILET 106 MECH 108 ELEC. 109 MENS TOILET 110 WOMENS TOILET 111 ATRIUM 112 LOBBY 113 MURPHY USA STORE 114 CUSTOMER EXPERIENCE 114A LOBBY TOILET ROOM 116 VENDOR CONFERENCE 117 VENDOR CONFERENCE 118 VENDOR CONFERENCE 119 CORRIDOR 120 OFFICE 121 WIRING CLOSET 122 FILE/ WORK 123 OFFICE 124 OFFICE 125 OFFICE 128 OFFICE 129 OFFICE 130 OFFICE 131 COPY 132 CONFERENCE 133A STORAGE 133B STORAGE 133C ELEC. 134 KITCHEN 135 DINING ROOM 136 BREAKOUT 137 VESTIBULE 138 CONFERENCE 140 WIRING CLOSET 141 OFFICE 142 OFFICE 143 OFFICE 145A TRAINING A 145B TRAINING B 146A STORAGE A 146B STORAGE B 147 OFFICE 148 OFFICE 149 OFFICE 150 COPY 151 OFFICE 152 OFFICE 153 CONFERENCE 154 CONFERENCE 155 CONFERENCE 156 CONFERENCE 157 ENCLOSED PATIO 158 COVERED PATIO 159 CORRIDOR 160 STORAGE 161 NW CORRIDOR 162 NE CORRIDOR 163 SW CORRIDOR E-1 ELEVATOR 1
E-2
Floor Finish Base Finish
Wall Finish Eash South
02 SECOND FLOOR 2XX CORRIDOR 2YY CORRIDOR 200 JAN 202 ELEC. 203 MECH 204 MENS TOILET 205 WOMENS TOILET 206 MECH 208 ELEC. 209 MENS TOILET 210 WOMENS TOILET 211 CONFERENCE 212 TEAMING 213 TEAMING 214 TEAMING 215 TEAMING 216 COPY 217 KITCHEN 218 COATS 219 DIRECTOR'S OFFICE 220 TEAMING 221 DIRECTOR'S OFFICE 222 TEAMING 223 ADMINISTRATIVE ASSISTANT 224 MANAGER'S OFFICE 225 DIRECTOR'S OFFICE 226 VP OFFICE 227 GUEST OFFICE 228 WIRING CLOSET 229 CONFERENCE 230 SR. DIRECTOR'S OFFICE 231 GUEST OFFICE 232 DIRECTOR'S OFFICE 233 DATA CENTER 234 COPY 235 DATA CENTER UPS 236 DATA CENTER STORAGE 237 FIRE SUPPRESSION VALVE 238 PRIVACY 239 TEAMING 240 SR. DIRECTOR'S OFFICE 241 SR. MANAGER'S OFFICE 242 MANAGER'S OFFICE 243 FILE/ STORAGE 244 MANAGER'S OFFICE 245 SR. DIRECTOR'S OFFICE 246 WIRING CLOSET 247 CONFERENCE 248 DIRECTOR'S OFFICE 249 FILES/ STORAGE 250 DIRECTOR'S OFFICE 251 DIRECTOR'S OFFICE 252 TEAMING 253 SR. MANAGER'S OFFICE OA-E2 OPEN WORKSTATION AREA OA-N2 OPEN WORKSTATION AREA OA-S2 OPEN WORKSTATION AREA OA-W2 OPEN WORKSTATION AREA
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
FINISH ROOM SCHEDULE
IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A AF-1, IPT-1 AF-1, IPT-1 NIC AF-1, IPT-1 IPT-1A ACT-2 ACT-2 ACT-2 IPT-1 ACT-2 IPT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-1 ACT-2 ACT-1 ACT-1 IPT-1 ACT-1 ACT-2, IPT-1A AF-1, IPT-1 IPT-1 ACT-2 IPT-1 ACT-2, IPT-1 ACT-2 ACT-2 ACT-2, IPT-1 ACT-2, IPT-1 ACT-1 ACT-1 ACT-2 ACT-2 ACT-2 ACT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 --IPT-1 ACT-1 IPT-1 IPT-1 AF-1, IPT-1 --
Room No
Room Name
Floor Finish Base Finish
Wall Finish Eash South
North
West
Ceiling Finish
Millwork Finish Vertical Horizontal Transaction
Comments
03 THIRD FLOOR 3XX CORRIDOR 3YY CORRIDOR 300 JAN 302 ELEC. 303 MECH 304 MENS TOILET 305 WOMENS TOILET 306 MECH 308 ELEC. 309 MENS TOILET 310 WOMENS TOILET 311 CONFERENCE 312 TEAMING 313 TEAMING 314 TEAMING 315 COFFEE 316 COATS 317 ENGINEERING CONFERENCE 318 HUDDLE 319 SR. MANAGER'S OFFICE 320 MANAGER'S OFFICE 321 MANAGER'S OFFICE 322 SR. DIRECTOR' S OFFICE 323 TEAMING 324 DIRECTOR'S OFFICE 325 CONFERENCE 326 GUEST OFFICE 327 WIRING CLOSET 328 VP OFFICE 329 CONFERENCE 330 DIRECTOR'S OFFICE 331 DIRECTOR'S OFFICE 332 DIRECTOR'S OFFICE 333 MANAGER'S OFFICE 334 MANAGER'S OFFICE 335 DIRECTOR'S OFFICE 336 HUDDLE 337 SR. DIRECTOR'S OFFICE 338 DIRECTOR'S OFFICE 339 SR. MANAGER'S OFFICE 340 FILES/ STORAGE 341 SR. MANAGER'S OFFICE 342 SR. DIRECTOR'S OFFICE 343 SR. DIRECTOR'S OFFICE 344 WIRING CLOSET 345 SR. DIRECTOR'S OFFICE 346 SR. VP OFFICE 347 ADMINISTRATIVE ASSISTANT 348 MANAGER'S OFFICE 349 COPY 350 SR. DIRECTOR'S OFFICE 351 VP OFFICE 352 MERCHANDISE DISPLAY AREA 353 MANAGER OFFICE 355 COPY 356 COFFEE/ KITCHEN OA-E3 OPEN WORKSTATION AREA OA-N3 OPEN WORKSTATION AREA OA-S3 OPEN WORKSTATION AREA OA-W3 OPEN WORKSTATION AREA
CPT-2 CPT-2 CONC-1 CONC-1 CONC-1 T-3 T-3 CONC-1 CONC-1 T-3 T-3 CPT-2 CPT-2 CPT-2 CPT-2 T-2 CPT-2 CPT-1 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-1 CPT-2 VCT-2 CPT-2 CPT-1 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-1 CPT-2 CPT-2 CPT-2 VCT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-3 CPT-2 CPT-2 CPT-2 CPT-2 VCT-3 T-2 CPT-2 CPT-2 CPT-2 CPT-2
RB-1 RB-1 RB-1 RB-1 RB-1 T-3 T-3 RB-1 RB-1 T-3 T-3 RB-1 RB-1 RB-1 RB-1 T-2 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 T-2 RB-1 RB-1 RB-1 RB-1
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2
IPT-2 IPT-2 IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2
IPT-1 IPT-1 IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A AF-1, IPT-1 AF-1, IPT-1 AF-1, IPT-1 AF-1, IPT-1 ACT-1 ACT-2, IPT-1 ACT-2 AF-1, IPT-1 ACT-2 ACT-2 ACT-2 ACT-2 AF-1, IPT-1 ACT-2 ACT-2 ACT-2 IPT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 AF-1, IPT-1 ACT-2 ACT-2 ACT-2 ACT-1 ACT-2 ACT-2 ACT-2 IPT-1 ACT-2 ACT-2 ACT-2, IPT-1 ACT-2 ACT-1 ACT-2 ACT-2, IPT-1 ACT-2, IPT-1 ACT-2 ACT-1 ACT-1 ACT-2, IPT-1 ACT-2, IPT-1 ACT-2, IPT-1 ACT-2, IPT-1
-----PL-1 PL-1 --PL-1 PL-1 WP-1 WP-1 WP-1 WP-1 PL-1 --WP-1 ----WP-1 -------------------------PL-1 ----PL-1 PL-1 -----
-----SSM-2 SSM-2 --SSM-2 SSM-2 SSM-2 SSM-2 SSM-2 SSM-2 SSM-1 --SSM-2 ----SSM-2 -------------------------SSM-1 ----SSM-1 SSM-1 -----
-------------------------------------------------------------
---------------T-5 AT BACKSPLASH, SEE ELEVATIONS PAINT ALL EXPOSED CEILING AREAS, IPT-1 ------------------------------PAINT ALL EXPOSED CEILING AREAS, IPT-1 ---PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 --T-5 AT BACKSPLASH, SEE ELEVATIONS PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1
04 FOURTH FLOOR 400 JAN 402 ELEC. 403 MECH 404 MENS TOILET 405 WOMENS TOILET 406 MECH 407 COMM. 408 ELEC. 409 MENS TOILET 410 WOMENS TOILET 411 CONFERENCE 413 CONFERENCE 414 OFFICE 415 OFFICE 416 OFFICE 417 COPY 418 WIRING CLOSET 419 INSURANCE 420 HSSE 421 CONFERENCE 422 OUTSIDE AUDITORS 423 CHECK ROOM 424 OFFICE 425 OFFICE 426 TREASURY 426A CORRIDOR 427 AUDIT 428 OFFICE 429 FILE/ WORK 430 EXPANSION 431 COFFEE/ KITCHEN 433 OFFICE 434 VP OFFICE 435 CONTROLLER 436 OFFICE 437 FILES/ WORK 438 OFFICE 439 OFFICE 440 OFFICE 441 COPY 442 CONFERENCE 443 VP OFFICE 444 CONFERENCE 445 OFFICE 446 OFFICE 447 OFFICE 448 WIRING CLOSET 449 OFFICE OF THE CEO 450 KITCHEN 451 A/V ROOM 452 TOILET 453 EXECUTIVE BOARDROOM
CONC-1 CONC-1 CONC-1 T-3 T-3 CONC-1 CONC-1 CONC-1 T-3 T-3 CPT-1 CPT-1 CPT-2 CPT-1 CPT-2 VCT-3 VCT-2 CPT-2 CPT-2 CPT-1 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 T-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 VCT-3 CPT-1 CPT-3 CPT-1 CPT-3 CPT-3 CPT-3 VCT-2 CPT-3 T-2 VCT-2 T-3 CPT-3
RB-1 RB-1 RB-1 T-3 T-3 RB-1 RB-1 RB-1 T-3 T-3 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 T-2 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 WB-1 RB-1 WB-1 WB-1 WB-1 RB-1 WB-1 T-2 RB-1 T-3 WB-1
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 T-4 WC-1
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 T-4 WC-1
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 T-4 WC-1
IPT-2A, WP-1 IPT-2A IPT-2A T-4 T-4 IPT-2A IPT-2A IPT-2A T-4 T-4 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2A IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 T-4 WC-1
IPT-1A IPT-1 IPT-1 IPT-1A IPT-1A IPT-1 IPT-1 IPT-1 IPT-1A ACT-3 AF-1, IPT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-1 IPT-1 ACT-2, IPT-1 ACT-2, IPT-1 ACT-2 ACT-2, IPT-1 ACT-2 ACT-2 ACT-2 ACT-2, IPT-1 IPT-1 ACT-2, IPT-1 ACT-2 ACT-2 ACT-2, IPT-1 ACT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 IPT-1 ACT-2, IPT-1 IPT-1 IPT-1 IPT-1A ACT-3
---PL-1 PL-1 ---PL-1 WP-1 -----PL-1 --------------PL-1 --------PL-1 ----------PL-1 --
---SSM-2 SSM-2 ---SSM-2 SSM-2 -----SSM-1 --------------SSM-1 --------SSM-1 ----------SSM-2 --
-----------------------------------------------------
FLOOR FINISH PATTERNS: HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
BY OWNER
CPT-1: CARPET TERR-1: TERRAZZO
CPT-1: CARPET
CPT-2: CARPET
CPT-3: CARPET
WOM-1: WALK OFF MAT
VCT-1: VINYL COMPOSITION TILE
VCT-2: VINYL COMPOSITION TILE (SDT)
VCT-3: VINYL COMPOSITION TILE
T-2: FLOOR TILE
T-3: FLOOR TILE
CONC-1: SEALED CONCRETE
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
454 455 456
TOILET COPY MEETING
T-3 VCT-1 CPT-3
T-3 RB-1 WB-1
T-4 IPT-2 WC-1
T-4 IPT-2 WC-1
T-4 IPT-2 WC-1
T-4 IPT-2 WC-1
IPT-1A ACT-1 ACT-3
PL-1 ---
SSM-2 ---
----
457 458
WET BAR CONFERENCE
T-2 CPT-3
T-2 WB-1
IPT-2A WC-1
IPT-2A WC-1
IPT-2A WC-1
IPT-2A WC-1
ACT-3 ACT-3
---
SSM-2 --
SSM-2 --
459 460 461 462 463 464 465 466 467 468 469 470 471 472 480 481 482 483 484 S-6
OFFICE OFFICE OFFICE EXECUTIVE CONFERENCE STORAGE EXECUTIVE VISITING OFFICE CONFERENCE LEGAL OFFICE OFFICE TEAMING OFFICE CENTRAL CORRIDOR NW CORRIDOR NE CORRIDOR SW CORRIDOR SE CORRIDOR PENTHOUSE STAIR
CPT-3 CPT-3 CPT-3 CPT-3 CPT-1 VCT-1 CPT-3 CPT-3 CPT-1 CPT-3 CPT-3 CPT-3 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 CPT-2 NIC
WB-1 WB-1 WB-1 WB-1 RB-1 RB-1 WB-1 WB-1 RB-1 WB-1 WB-1 WB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 NIC
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 NIC
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 NIC
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 NIC
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 NIC
ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-1 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2 ACT-2, IPT-1 ACT-2 IPT-1 IPT-1 IPT-1 IPT-1 IPT-1 NIC
---------WP-1 ---------NIC
---------SSM-2 ---------NIC
---------SSM-2 ---------NIC
---------REUSE EXISTING CEILING GRID, REPAIR AND PAINT DRAPERY (D-1) AT PERIMETER. ------PAINT ALL EXPOSED CEILING AREAS, IPT-1 PAINT ALL EXPOSED CEILING AREAS, IPT-1 -PAINT ALL EXPOSED CEILING AREAS, IPT-1 ---PAINT ALL EXPOSED CEILING AREAS, IPT-1 -PAINT ALL EXPOSED CEILING AREAS, IPT-1 --PAINT ALL EXPOSED CEILING AREAS, IPT-1 T-5 AT BACKSPLASH, SEE ELEVATIONS --------------------REUSE EXISTING CEILING GRID, REPAIR AND PAINT. REPLACE DRAPERY IF PRESENT (D-2). --REUSE EXISTING CEILING GRID, REPAIR AND PAINT. REPLACE DRAPERY IF PRESENT (D-2). -REUSE EXISTING CEILING GRID, REPAIR AND PAINT. REPLACE DRAPERY IF PRESENT (D-2). ------------PAINT ALL EXPOSED CEILING AREAS, IPT-1 --------
CONC-1 CONC-1 CONC-1 CONC-1 CONC-1 RF-1
RB-1 RB-1 RB-1 RB-1 RB-1 --
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-2 IPT-2 IPT-2 IPT-2 IPT-2 --
IPT-1 IPT-1 IPT-1 IPT-1 IPT-1 --
-------
-------
-------
-------
05 PENTHOUSE FLOOR P-01 STORAGE -1 P-02 MECH P-03 ELEVATOR PENTHOUSE P-04 MECH P-05 STORAGE-2 P-10 ATRIUM
FINISH LEGEND
RF-1: RESINOUS FLOORING
Murphy USA
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FINISH SCHEDULE
CD
I-001
12/1/2015 4:44:01 PM
PRIMARY Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
FURNITURE BLOCK KEY BLOCK
DESCRIPTION
RECEPTION, WAITING AREAS
BLOCK
DESCRIPTION
CONFERENCE, TRAINING, TEAMING, WORK AREAS
BLOCK
DESCRIPTION
OPEN OFFICE AREAS
CREDENZA 18" D X 60" W X 36" H
WORK SURFACE 12" D X 36" W
LOUNGE CHAIR 30" W X 32" D, SEAT H: 16"
CREDENZA, LARGE 18" D X 96" W X 36" H
WORK SURFACE 21" D X 36" W
END TABLE, ROUND 24" DIA X 20" H
END TABLE, SQUARE 18" D X 24" W X 20" H
CONFERENCE TABLE, 8 SEAT 48" D X 102" W X 30" H CONFERENCE TASK CHAIR 28" W X 28" D, SEAT H: 14-18"
EXEC COCKTAIL TABLE 18" D X 60" W
LOUNGE CHAIR, LEATHER 30" W X 32" D, SEAT H: 16"
WORK SURFACE 24" D X 30" W
EXEC END TABLE, ROUND 24" DIA X 20" H
WORK SURFACE 24" D X 36" W
EXEC END TABLE, SQUARE 18" D X 24" W X 20" H
WORK SURFACE 25" D X 36" W DINING, KITCHEN, COFFEE AREAS
DESCRIPTION
EXECUTIVE SUITE, PRIVATE OFFICES, AND CONFERENCE ROOMS
COCKTAIL TABLE 18" D X 60" W
CONFERENCE TABLE, 6 SEAT 48" D X 72" L X 30" H CONFERENCE TASK CHAIR 28" W X 28" D, SEAT H: 14-18"
BLOCK
WORK SURFACE 30" D X 30" W
BAR STOOL, COUNTER HEIGHT 28" W X 28" D, SEAT H: 20"
TYPE 'A' WORK STATION, U CONFIGURATION 104" D X 104" W, HEIGHT VARIES EXECUTIVE TASK CHAIR, LEATHER 24" D X 24" W, SEAT H: 14-18" SIDE CHAIRS W/ ARMS 22" D X 22" W, SEAT H: 16"
WORK SURFACE 12" D X 36" W BAR STOOL, BAR HEIGHT 28" W X 28" D, SEAT H: 30" DINING TABLE, 2 SEAT 30" D X 32" W X 30" H DINING CHAIR ,W/O ARMS 20" W X 20" D, SEAT H: 16"
DINING TABLE, 4 SEAT 42" DIA X 30" H DINING CHAIR ,W/O ARMS 20" W X 20" D, SEAT H: 16"
CONFERENCE TABLE, 10 SEAT 48" D X 126" W X 30" H CONFERENCE TASK CHAIR 28" W X 28" D, SEAT H: 14-18"
WORK SURFACE 36" D X 36" W
WORK SURFACE 96" D X 96" W X 30" H TASK CHAIR 22" D X 22" W, SEAT H: 14-18" CONFERENCE TABLE, 14 SEAT 48" D X 180" W X 30" H CONFERENCE TASK CHAIR 28" W X 28" D, SEAT H: 14-18"
WORK STATION 96" D X 96" W X 30" H TASK CHAIR 22" D X 22" W, SEAT H: 14-18"
DINING TABLE, BAR HEIGHT, 4 SEAT 42" DIA X 30" H DINING CHAIR ,W/O ARMS 20" W X 20" D, SEAT H: 16" CONFERENCE TABLE, 4 SEAT 48" DIA X 30" H CONFERENCE TASK CHAIR 28" W X 28" D, SEAT H: 14-18"
TYPE 'A' WORK STATION, U CONFIGURATION 104" D X 104" W, HEIGHT VARIES EXECUTIVE TASK CHAIR 24" D X 24" W, SEAT H: 14-18" SIDE CHAIRS W/O ARMS 22" D X 22" W, SEAT H: 16"
TRAINING TABLE, 2 SEAT 24" D X 54" W X 30" H SIDE CHAIR 20" W X 20" D, SEAT H: 16"
TYPE 'B' WORK STATION, U CONFIGURATION 104" D X 104" W, HEIGHT VARIES EXECUTIVE TASK CHAIR 24" D X 24" W, SEAT H: 14-18" SIDE CHAIRS W/O ARMS 22" D X 22" W, SEAT H: 16"
WORK SURFACE 30" D X 36" W
WORK SURFACE 18" D X 36" W
EXEC CREDENZA, LARGE 18" D X 96" W X 36" H
CONFERENCE TABLE, 6 SEAT 72" DIA X 30" H CONFERENCE TASK CHAIR 28" W X 28" D, SEAT H: 14-18"
LATERAL FILE, 5 HIGH 18" D X 36" W X 72" H
PODIUM 22" D X 36" W X 54" H
LOUNGE CHAIR W/ TABLET ARM 30" D X 32" W, SEAT H: 16"
TYPE 'A' WORK STATION, EXEC CONFIGURATION 104" D X 104" W, HEIGHT VARIES EXECUTIVE TASK CHAIR, LEATHER 24" D X 24" W, SEAT H: 14-18" SIDE CHAIRS W/ ARMS 22" D X 22" W, SEAT H: 16"
EXEC CREDENZA 18" D X 60" W X 36" H
PRIVATE OFFICE AREAS
FILING
LATERAL FILE, 3 HIGH 18" D X 36" W X 36" H
TYPE 'A' WORK STATION, EXEC CONFIGURATION 114" D X 114" W, HEIGHT VARIES EXECUTIVE TASK CHAIR, LEATHER 24" D X 24" W, SEAT H: 14-18" SIDE CHAIRS W/ ARMS 22" D X 22" W, SEAT H: 16"
EXEC CONFERENCE TABLE, 6 SEAT 48" D X 72" L X 30" H CONFERENCE TASK CHAIR, LEATHER 28" W X 28" D, SEAT H: 14-18"
EXEC CONFERENCE TABLE, 10 SEAT 48" D X 126" W X 30" H CONFERENCE TASK CHAIR, LEATHER 28" W X 28" D, SEAT H: 14-18"
TYPE 'B' WORK STATION, SMALL CONFIGURATION 78" D X 72" W, HEIGHT VARIES EXECUTIVE TASK CHAIR 24" D X 24" W, SEAT H: 14-18" SIDE CHAIRS W/O ARMS 22" D X 22" W, SEAT H: 16"
CONFERENCE TABLE, 4 SEAT 48" DIA X 30" H SIDE CHAIRS W/O ARMS 22" D X 22" W, SEAT H: 16"
Checked by:
Checker
Murphy USA
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
Drawn by:
Author
FURNITURE SCHEDULE
CD
I-002
PRIMARY 12/1/2015 4:44:13 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
FINISH LEGEND FLOOR FINISH PATTERNS: HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
BY OWNER
CPT-1: CARPET TERR-1: TERRAZZO
CPT-1: CARPET
CPT-2: CARPET
SERVICE COURT CPT-3: CARPET
WOM-1: WALK OFF MAT
VCT-1: VINYL COMPOSITION TILE
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
VCT-2: VINYL COMPOSITION TILE (SDT)
U
VCT-3: VINYL COMPOSITION TILE
0.0
T-2: FLOOR TILE
T-3: FLOOR TILE
CONC-1: SEALED CONCRETE
SERVICE DOCK
0.8
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
1 RF-1: RESINOUS FLOORING
FIRE PUMP
2 CHILLERS 3
3.9
4
RECEIVING 5
001 CONC-1
6
TOILET MECH EQUIPMENT ROOM
012 CONC-1
UP
002
7
CONC-1
FIBER TELECOM
8
011 CONC-1
9
10 HOT WATER SYSTEMS CONC-1
11
ELEV. EQUIP. 12
009 CONC-1
CORRIDOR 008
13
CONC-1
MAIN ELECTRICAL CONC-1
14
007
Checker
004
003
CONC-1
CONC-1
Murphy USA
15
17
005
Checked by:
PRINT ROOM
16
BUILDING OPERATIONS/ MECHANICS CONC-1
MAIL ROOM
Commision #15054.00 200 Peach Street El Dorado, AR 71730
CONC-1
18
19
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
Drawn by:
Author
BASEMENT FINISH PLAN
1
00 BASEMENT FINISH PLAN 1/8" = 1'-0"
CD
I-100
12/1/2015 4:44:32 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW 0.0
DN
COVERED PATIO
ENCLOSED PATIO
158
157
STONE PAVING
T-2
FINISH LEGEND 0.8 1
EXTERIOR VESTIBULE 158
BY OWNER
STONE PAVING
STONE PAVING
3
TRAINING A
TRAINING B
145A
145B
DINING ROOM
CPT-2
CPT-2
135
CPT-1: CARPET TERR-1: TERRAZZO
4 REF CPT-1: CARPET
T-2
KITCHEN UP
DN
14
134
A-512
RF-1
2
NW STAIR 1
VESTIBULE
RF-1
STORAGE A
S-1
STORAGE B
VCT-1
146A
146B
HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
2
137B
COVERED PATIO
FLOOR FINISH PATTERNS:
137
5 CPT-2: CARPET
UP
NE STAIR 2
A-512
6
S-2
WOM-1
RF-1
VCT-1
CPT-3: CARPET
7 2
NW CORRIDOR
8
8
A-512
A-512 CPT-2
161
141
143
A-512
CPT-2
CPT-2
OFFICE
E-3
106
OFFICE
12
108
WIRING CLOSET
OFFICE
140
142
CONC-1
12
A-512
CONC-1
A-512
CONFERENCE
COPY
OFFICE
OFFICE
OFFICE
132
131
130
129
128
CPT-1
VCT-3
CPT-2
CPT-2
CPT-2
CPT-1 6
CPT-2
VCT-2
8
CONC-1
133B
133C
2
WOMENS TOILET
A-512
105 T-3
9
10
WOM-1: WALK OFF MAT
VCT-1: VINYL COMPOSITION TILE
VCT-2: VINYL COMPOSITION TILE (SDT)
TERR-1
138
A-512
133A
12
136
CONFERENCE 3
8
ELEC. STORAGE
BREAKOUT
CONC-1
ELEC.
CONC-1
A-512
TERR-1
STORAGE
SERVICE ELEVATOR
MECH
162
14
A-512
NE CORRIDOR
11
MENS TOILET
2
A-512
104
A-512
A-512
VCT-3: VINYL COMPOSITION TILE
12 T-2: FLOOR TILE
T-3
13 5 A-512
UP
T-3: FLOOR TILE
5
6
8
A-512
A-512
A-512
14 CONC-1: SEALED CONCRETE
15
OPEN WORKSTATION AREA
OPEN WORKSTATION AREA OA-W1
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
16
OA-E1
TERR-1
CPT-2
RF-1: RESINOUS FLOORING
17
CPT-2
18
ATRIUM 111
19
TERR-1
20
21 8 A-512
22
OFFICE 148
OFFICE
COPY
OFFICE
OFFICE
150
151
152
VCT-3
CPT-2
A-512
OFFICE 11
125
124
123
122
121
5
OFFICE
CPT-2
CPT-2
VCT-2
A-512
120
5
7
A-512
A-512
STORAGE
ELEVATOR 1
ELEVATOR 2
160
E-1
E-2
149
CPT-1
23
25
ELEC. 102
VCT-1
SW CORRIDOR
MURPHY USA STORE
163
113
110
MECH
CONC-1
103 CONC-1 7
11
OPEN WORKSTATION AREA
A-512
OA-S1
LOBBY 7 TERR-1
A-512
JAN. 101
CONC-1
SW STAIR 3 5
114
A-512
TERR-1
Murphy USA 30
5
5
CORRIDOR
A-512
A-512
159
TERR-1
5
5
A-512
A-512
TERR-1
31 RF-1
114A
SE STAIR 4
TERR-1
5
5
5
5
A-512
A-512
A-512
A-512
UP
Checked by:
Checker
LOBBY TOILET ROOM
CUSTOMER EXPERIENCE
UP
S-4
32
33
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
34
CONFERENCE
CONFERENCE
CONFERENCE
CONFERENCE
156
155
154
153
CPT-1
CPT-1
CPT-1
CPT-1
ENTRANCE FLOOR GRILL 4
Author
A-503
Drawn by:
29
CORRIDOR 119
RF-1
27
28
112
CPT-2
S-3
26
A-512
CPT-2
WOMENS TOILET
24
CPT-2
CPT-2
A-512 T-3
T-3
OFFICE
CPT-2
8
109
OFFICE
CPT-2
CPT-2
MENS TOILET
OFFICE
CPT-2
147
WIRING CLOSET
FILE/ WORK
STONE PAVING
VENDOR CONFERENCE
VENDOR CONFERENCE
VENDOR CONFERENCE
116
117
118
CPT-1
CPT-1
CPT-1
36
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
37
FIRST FLOOR FINISH PLAN
35
CD
I-101
12/1/2015 4:45:01 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
0.0
FINISH LEGEND FLOOR FINISH PATTERNS:
0.8
HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
1
DIRECTOR'S OFFICE
SR. DIRECTOR'S OFFICE
OPEN WORKSTATION AREA
232
BY OWNER
240
2
OA-N2
CPT-2
CPT-1: CARPET TERR-1: TERRAZZO
CPT-2
3
CPT-2
3.9
GUEST OFFICE
8
231
SR. MANAGER'S OFFICE
8
A-512
A-512
241
CPT-2
CPT-2
COPY UP
NW STAIR 1
SR. DIRECTOR'S OFFICE
RF-1
S-1
CPT-1: CARPET
4
234 VCT-3
230 DN
DATA CENTER UPS
DATA CENTER STORAGE
235
236
VCT-2
VCT-2
FIRE SUPPRESSION VALVE
PRIVACY
237
CPT-2
238
MANAGER'S OFFICE
TEAMING 239
NE STAIR 2
242
UP
E-3
8
243
WOMENS TOILET
11
205
A-512
VCT-1
244
208
A-512
VCT-1: VINYL COMPOSITION TILE
9
VCT-2: VINYL COMPOSITION TILE (SDT)
10 VCT-3: VINYL COMPOSITION TILE
CPT-2
11 T-2: FLOOR TILE
8 A-512
CONC-1
8
T-3
MANAGER'S OFFICE
CONC-1
3
WOM-1: WALK OFF MAT
FILE/ STORAGE
VCT-2
ELEC.
7
A-512
A-512
206
CPT-3: CARPET
8 UP
233
MECH
6
S-2
DATA CENTER
SERVICE ELEVATOR
CPT-2: CARPET
DN CPT-2
8 A-512
UP
RF-1
CPT-2
VCT-1
CPT-2
5
CORRIDOR
CORRIDOR
2YY
2YY
5
11
MENS TOILET
A-512
204
12
T-3
T-3: FLOOR TILE
A-512 6 A-512
13
WIRING CLOSET
CONC-1: SEALED CONCRETE
DN
228
CONFERENCE
14
VCT-2
229
TEAMING
TEAMING
212
213
CPT-2
CPT-2
CPT-1
GUEST OFFICE
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
15
OPEN WORKSTATION AREA
227 CPT-2
16
RF-1: RESINOUS FLOORING
OA-E2
TERR-1
17
CPT-2
18
OPEN WORKSTATION AREA
TEAMING 19
214
OA-W2
CPT-2
CPT-2
20
CONFERENCE 6
DIRECTOR'S OFFICE
A-512
SR. MANAGER'S OFFICE
211
21
253
CPT-1
SR. DIRECTOR'S OFFICE
225
22
245
TEAMING
CPT-2
VP OFFICE
ATRIUM
215
CONFERENCE
MANAGER'S OFFICE
226
23
CPT-2
CPT-2
224
WIRING CLOSET
247
246
CPT-1
CPT-2
6
VCT-2 CPT-2
MENS TOILET
11
209
A-512
CORRIDOR
ELEVATOR 1
ELEVATOR 2
E-1
E-2
2XX
T-3
ADMINISTRATIVE ASSISTANT
T-2
11
223
T-3
WOMENS TOILET 210
11
TEAMING
A-512
222 CPT-2
COPY KITCHEN
T-2
217
25
CORRIDOR
8
ELEC.
2XX
A-512
202
MECH
CONC-1
VCT-3
26
203 CONC-1
248
3
CPT-2
A-512
216
REF
CPT-2
A-512
DIRECTOR'S OFFICE
A-512
24
27
28
FILES/ STORAGE 249 CPT-2
3 A-512
JAN CONC-1
200
29
COATS 218
8
30
Checked by:
Checker
A-512
DIRECTOR'S OFFICE
SW STAIRDN 3 S-3
RF-1
221
UP
OPEN WORKSTATION AREA OA-S2
31
DIRECTOR'S OFFICE RF-1 CPT-2
CPT-2
TEAMING
DIRECTOR'S OFFICE
220
251
CPT-2
CPT-2
SE STAIR 4 UP
S-4
32
34
Author Drawn by:
CPT-2
TEAMING 252
Westlake Reed Leskosky
33
35
219
Commision #15054.00 200 Peach Street El Dorado, AR 71730
DN
250
CPT-2
DIRECTOR'S OFFICE
Murphy USA
36
CPT-2
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
SECOND FLOOR FINISH PLAN
37
CD
I-102
12/1/2015 4:45:20 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
FINISH LEGEND EXTERIOR VESTIBULE
0.8
137B
DIRECTOR'S OFFICE
MANAGER'S OFFICE
332
333
CPT-2
CPT-2
1
SR. DIRECTOR'S OFFICE
FLOOR FINISH PATTERNS: HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
2
337
BY OWNER CPT-2
3
MANAGER'S OFFICE
DIRECTOR'S OFFICE
3.9
OPEN WORKSTATION AREA
331 CPT-2
DIRECTOR'S OFFICE
334
OPEN WORKSTATION AREA
CPT-2
OA-N3
DIRECTOR'S OFFICE
STAIRS UP NW STAIR 1 S-01 S-1
4
338
CPT-1: CARPET
CPT-2
5
OA-N3
DIRECTOR'S OFFICE
CPT-2
330
RF-1
CPT-1: CARPET TERR-1: TERRAZZO
SR. MANAGER'S OFFICE
CPT-2
UP
NE STAIR 2
339
335
RF-1
DN
306
E-3
MERCHANDISE DISPLAY AREA
CONFERENCE 6
CPT-1
8
COPY
A-512
355
VCT-3
SR. MANAGER'S OFFICE
REF
COFFEE/ KITCHEN
352
329
CONC-1
CPT-2
CPT-2
SERVICE ELEVATOR
MECH
S-2
DN CPT-2
WOMENS TOILET
11 A-512
8
WOM-1: WALK OFF MAT
9
VCT-1: VINYL COMPOSITION TILE
341 T-2
10
CPT-2
CPT-2
VCT-2: VINYL COMPOSITION TILE (SDT)
11 VCT-3: VINYL COMPOSITION TILE
CPT-2 11
A-512
CORRIDOR
8
CORRIDOR
A-512
3XX
11
MENS TOILET
A-512
304
3XX
A-512
CONC-1
CPT-3: CARPET
356
3
308
7
T-3
305
A-512
ELEC.
CPT-2: CARPET
6
5
12 T-2: FLOOR TILE
T-3
A-512
13 T-3: FLOOR TILE
VP OFFICE
WIRING CLOSET
328
327
TEAMING
VCT-2
CPT-2
312
HUDDLE 336
GUEST OFFICE
14
OPEN WORKSTATION AREA
CONC-1: SEALED CONCRETE
15
OA-E3
CPT-2
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
CPT-2
326
16 TERR-1
CPT-2
RF-1: RESINOUS FLOORING
17
18
FILES/ STORAGE
OPEN WORKSTATION AREA
340
TEAMING
OPEN TO BELOW
MANAGER OFFICE
CPT-2
OA-W3
CONFERENCE CPT-2
311
CPT-2
ATRIUM
CPT-1
SR. DIRECTOR'S OFFICE
CPT-2
342
SR. DIRECTOR'S OFFICE
20
CPT-2
SR. DIRECTOR'S OFFICE
A-512 6
TEAMING
SR. VP OFFICE
DIRECTOR'S OFFICE
WIRING CLOSET
309
A-512
24
CPT-2
344 VCT-2
CPT-2
MENS TOILET
ELEVATOR 1
ELEVATOR 2
E-1
E-2
25
CORRIDOR
8
ELEC.
A-512
302
CORRIDOR
3YY
T-3
3YY
CORRIDOR 11
TEAMING
MECH
CONC-1
ADMINISTRATIVE ASSISTANT
T-2
347
CPT-2
CPT-2
CONC-1
A-512
11
SR. DIRECTOR' S OFFICE
310
A-512
322
COFFEE 315
T-2
MANAGER'S OFFICE
3
348
A-512
REF
WOMENS TOILET
CPT-2
JAN 300
CONC-1
Checked by:
Checker
316
MANAGER'S OFFICE
DN RF-1
MANAGER'S OFFICE 320 CPT-2
30
ENGINEERING CONFERENCE
COPY
8
349
A-512
OPEN WORKSTATION AREA
CPT-1
SR. DIRECTOR'S OFFICE
SE STAIR 4 S-4
32
33
350
OA-S3
Author
Westlake Reed Leskosky
CPT-2
VP OFFICE
A-512
SR. MANAGER'S OFFICE
HUDDLE
319
318
35
36
CPT-2 CPT-2
37
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
34
CPT-2
6
351
CPT-2
DN
UP
OA-S3 CPT-2
31
RF-1
317
OPEN WORKSTATION AREA
Murphy USA
CPT-2
VCT-3
321 CPT-2
29
CPT-2
COATS
UP
27
3
28
T-3
S-3
26
303
3YY
A-512
323
SW STAIR 3
23
346
CPT-2
324
11
22
CPT-2
314
CPT-1
CPT-2
343
A-512
325
21
345
6
CONFERENCE
19
353
313
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
THIRD FLOOR FINISH PLAN
CD
I-103
12/1/2015 4:45:43 PM
PRIMARY
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
FINISH LEGEND FLOOR FINISH PATTERNS:
0.8 1
OFFICE
2
425
TREASURY
CPT-2
VP OFFICE
OFFICE
434
436
426
CPT-2
OFFICE
AUDIT
430
424
427
CPT-2
CPT-2
CPT-2
3
CPT-1: CARPET TERR-1: TERRAZZO
4
CPT-1: CARPET
5
CPT-2: CARPET
CONTROLLER 435 CPT-2
OFFICE 433
FILES/ WORK
CPT-2
NW STAIR 1
437
CHECK ROOM RF-1
S-1
423
DN
NE STAIR 2
RF-1
6 CPT-3: CARPET
S-2
CPT-2
DN
OFFICE
CPT-2
7
428
CORRIDOR
NW CORRIDOR
WOM-1: WALK OFF MAT
CPT-2
CPT-2
426A
481
BY OWNER
CPT-2
EXPANSION
CPT-2
3.9
HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
6
8
NE CORRIDOR
A-512
A-512
482
8 VCT-1: VINYL COMPOSITION TILE
REF
MECH 406
SERVICE ELEVATOR
CONC-1
E-3
T-2
FILE/ WORK 429
OUTSIDE AUDITORS
TEAMING
422
471
CPT-2
CONFERENCE
COPY
OFFICE
OFFICE
OFFICE
442
441
440
439
438
CPT-2
CPT-2
COFFEE/ KITCHEN
CPT-2
CPT-1
VCT-3
CPT-2
11
WOMENS TOILET
A-512
405
T-3
VCT-2: VINYL COMPOSITION TILE (SDT)
10 VCT-3: VINYL COMPOSITION TILE
11
431
COMM.
ELEC.
3
407
408
A-512
CPT-2 11 8
CONC-1
T-2: FLOOR TILE
CENTRAL CORRIDOR
A-512
A-512
CONC-1
MENS TOILET
11 A-512
5
480
T-3
CONFERENCE
WIRING CLOSET
OFFICE
418
472
421
13 444 6
CPT-1
A-512
443
OFFICE
A-512
14
CONC-1: SEALED CONCRETE
15
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
16
RF-1: RESINOUS FLOORING
VP OFFICE
A-512 6
T-3: FLOOR TILE
CONFERENCE
VCT-2
6
12
404
A-512
CPT-1
9
CPT-3
415
OFFICE 445
CPT-1 TERR-1
HSSE
CPT-3
17
420
OFFICE
CPT-2
416
CENTRAL CORRIDOR
CPT-2
480
OFFICE 18
446
CPT-2
CPT-3
CENTRAL CORRIDOR
OPEN TO BELOW
8
OFFICE OF THE CEO
480
A-512
COPY
19
449 CPT-2
417
OFFICE
ATRIUM CONFERENCE
VCT-3
20
CPT-3
447 CPT-3
21
411
6 A-512
CPT-1
OFFICE INSURANCE
6
448
CPT-2
419
22
WIRING CLOSET
414
A-512
VCT-2
23
6
CPT-2
A-512
8
CONFERENCE
24
A-512
413 CPT-1
MENS TOILET
11
409 T-3
CPT-2
LEGAL
OFFICE
OFFICE
468
470
469
CPT-3
CPT-3
CPT-3
T-3
WOMENS TOILET
11
410
A-512
E-1
E-2
11 A-512
A-512
STORAGE EXECUTIVE VISITING
ELEVATOR 2 11
CPT-2
A-512
ELEVATOR 1
T-2
464
11
VCT-1
A-512
Checker Checked by:
SW STAIR 3 S-3
402
A-512
6 A-512
A-512
8
TOILET
403
455
454
CONC-1
VCT-1
T-3
KITCHEN 450
3
8
11
A-512
A-512
3
CONFERENCE
CONFERENCE CPT-1
CONC-1
29
A-512
452
A/V ROOM
MEETING
468
28
TOILET T-3
451
8
JAN
VCT-2
A-512
400
31
CPT-3
EXECUTIVE
CPT-3
DN
CPT-3
6
RF-1
A-512
CPT-1
EXECUTIVE BOARDROOM
SE STAIR 4 S-4
33
Westlake Reed Leskosky
453 CPT-3
OFFICE OFFICE 466 CPT-3
Author
Commision #15054.00 200 Peach Street El Dorado, AR 71730
32
34
WET BAR
Drawn by:
Murphy USA
30
456
462
467
27
A-512
T-2
A-512
LEGAL
MECH
COPY
UP
CPT-3
463
26
CONC-1
11
DN
RF-1
S-6
11
SW CORRIDOR 483
ELEC.
465
A-512
6
25
PENTHOUSE STAIR
461 CPT-3
OFFICE
OFFICE
CONFERENCE
457
460
459
458
T-2
CPT-3
CPT-1
CPT-3
35
11 A-512
36
37
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FOURTH FLOOR FINISH PLAN
CD
I-104
12/1/2015 4:45:50 PM
PRIMARY A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
AA
BB
CC
DD
EE
FF
GG
HH
JJ
KK
LL
MM
NN
PP
RR
SS
TT
UU
VV
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
WW
0.0
FINISH LEGEND FLOOR FINISH PATTERNS: HATCH PATTERN INDICATES EXTENTS AND DIRECTION OF FLOOR FINISH MATERIAL. SEE ARCHITECTUAL PLANS FOR INSTALL AND TRANSITION DETAILS.
0.8 1
3.9
BY OWNER
2
CPT-1: CARPET TERR-1: TERRAZZO
3
CPT-1: CARPET
4
CPT-2: CARPET
5 CPT-3: CARPET
6 WOM-1: WALK OFF MAT
7 VCT-1: VINYL COMPOSITION TILE
8 ROOF VCT-2: VINYL COMPOSITION TILE (SDT)
9 VCT-3: VINYL COMPOSITION TILE
10 T-2: FLOOR TILE
11
12
T-3: FLOOR TILE
13
CONC-1: SEALED CONCRETE
14
R-1: RUBBER FLOORING, TREAD, RISER, NOSING
15
RF-1: RESINOUS FLOORING
16
17
18
OPEN TO BELOW
19
20
21
22
23
24
25
26
STORAGE-2
MECH P-04
P-05
P-03 CONC-1
CONC-1
ELEVATOR PENTHOUSE CONC-1
MECH P-02 CONC-1
STORAGE -1
27
P-01 CONC-1 DN
28
Murphy USA
Checker
29
30
Checked by:
31
32
33 ROOF
34
Author
35
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
36
37
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
PENTHOUSE FLOOR FINISH PLAN
CD
I-105
PRIMARY 12/1/2015 4:45:57 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
FURNITURE LEGEND FURNITURE LAYOUTS: FURNITURE LAYOUTS INDICATE LOCATION AND QUANTITY OF FURNITURE FOR REFERENCE ONLY. ALL FURNITURE TO BE FINIALIZED, SUPPLIED, AND INSTALL BY OWNER. SEE SHEET F-100 FOR FURNITURE ANNOTATION AND BLOCKING KEY.
N.I.C. - INDICATES AREA NOT IN CONTRACT
FIRE PUMP
CHILLERS
RECEIVING 001
MECH EQUIPMENT ROOM
TOILET
002
012
UP
FIBER TELECOM 011
STORAGE 010
HOT WATER SYSTEMS
ELEV. EQUIP. 009
CORRIDOR
MAIL ROOM
008
004
Murphy USA
MAIN ELECTRICAL 007
PRINT ROOM
Checker
003
Checked by:
Westlake Reed Leskosky
BUILDING OPERATIONS/ MECHANICS
Author
005
Drawn by:
Commision #15054.00 200 Peach Street El Dorado, AR 71730
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
BASEMENT FURNITURE PLAN
CD 1
BASEMENT FURNITURE PLAN 1/8" = 1'-0"
I-200
PRIMARY 12/1/2015 4:46:06 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
DN
ENCLOSED PATIO 157
COVERED PATIO 158
FURNITURE LEGEND FURNITURE LAYOUTS: FURNITURE LAYOUTS INDICATE LOCATION AND QUANTITY OF FURNITURE FOR REFERENCE ONLY. ALL FURNITURE TO BE FINIALIZED, SUPPLIED, AND INSTALL BY OWNER. SEE SHEET F-100 FOR FURNITURE ANNOTATION AND BLOCKING KEY.
N.I.C. - INDICATES AREA NOT IN CONTRACT
DINING ROOM 135
TRAINING A
TRAINING B
145A
145B
REF
UP
NW STAIR 1 DN
VESTIBULE
S-1
STORAGE A
STORAGE B
146A
146B
143
OFFICE
106
141
NE STAIR 2 S-2
134
137
OFFICE
MECH
UP
KITCHEN
STORAGE
STORAGE
ELEC.
133A
133B
133C
WOMENS TOILET 105
OFFICE COPY
142
WIRING CLOSET
131
140
MENS TOILET
ELEC.
CONFERENCE
108
104
138
CONFERENCE
OFFICE
OFFICE
OFFICE
132
130
129
128
UP
OPEN WORKSTATION AREA OA-E1
OPEN WORKSTATION AREA OA-W1
ATRIUM 111
COPY
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
FILE/ WORK
150
151
152
125
124
123
122
OFFICE 120
OFFICE
WIRING CLOSET
148
121
OFFICE 147
MENS TOILET
OFFICE
STORAGE
109
149
160
ELEVATOR 1
ELEVATOR 2
E-1
E-2
ELEC. 102
MURPHY USA STORE
MECH 103
113
LOBBY 112
WOMENS TOILET
JAN.
110
101
OPEN WORKSTATION AREA
Murphy USA
CORRIDOR 119
OA-S1
Checker
CUSTOMER EXPERIENCE
LOBBY TOILET ROOM
114
114A
UP
UP
S-4
Checked by:
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FIRST FLOOR FURNITURE PLAN
Author Drawn by:
SE STAIR 4
Commision #15054.00 200 Peach Street El Dorado, AR 71730
1
FIRST FLOOR FURNITURE PLAN 1/8" = 1'-0"
CONFERENCE
CONFERENCE
CONFERENCE
CONFERENCE
156
155
154
153
VENDOR CONFERENCE
VENDOR CONFERENCE
VENDOR CONFERENCE
116
117
118
CD
I-201
PRIMARY 12/1/2015 4:46:26 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
OPEN WORKSTATION AREA
FURNITURE LEGEND
OA-N2
SR. DIRECTOR'S OFFICE
FURNITURE LAYOUTS: FURNITURE LAYOUTS INDICATE LOCATION AND QUANTITY OF FURNITURE FOR REFERENCE ONLY. ALL FURNITURE TO BE FINIALIZED, SUPPLIED, AND INSTALL BY OWNER.
240
SEE SHEET F-100 FOR FURNITURE ANNOTATION AND BLOCKING KEY.
DIRECTOR'S OFFICE
SR. MANAGER'S OFFICE
232
241
N.I.C. - INDICATES AREA NOT IN CONTRACT
GUEST OFFICE 231
MANAGER'S OFFICE
PRIVACY SR. DIRECTOR'S OFFICE
238
242
230
DATA CENTER FIRE DATA CENTER UPS SUPPRESSION STORAGE 235 VALVE 236
COPY UP
234
NW STAIR 1
TEAMING
237
S-1
UP
239
NE STAIR 2 S-2
DN
DN
UP
UP
DATA CENTER 233
FILE/ STORAGE
WOMENS TOILET
243
205
MECH 206
ELEC.
MANAGER'S OFFICE
MENS TOILET
244
204
208
TEAMING
DN
WIRING CLOSET
213
228
CONFERENCE 229
OPEN WORKSTATION AREA OA-E2
GUEST OFFICE 227
OPEN WORKSTATION AREA
TEAMING 212
OA-W2
TEAMING
OPEN TO BELOW
214
DIRECTOR'S OFFICE 225
SR. MANAGER'S OFFICE
SR. DIRECTOR'S OFFICE
253
245
CONFERENCE 247
CONFERENCE 211
TEAMING
VP OFFICE
WIRING CLOSET 246
215
226
MENS TOILET
MANAGER'S OFFICE
209
ELEVATOR 1
ELEVATOR 2
E-1
E-2
ELEC.
224
202
DIRECTOR'S OFFICE
ADMINISTRATIVE ASSISTANT MECH
223
248
203
KITCHEN 217
WOMENS TOILET
TEAMING
REF
210
COPY
222
216
FILES/ STORAGE
JAN
249
200
Murphy USA
COATS
Checker
OPEN WORKSTATION AREA
218
Commision #15054.00 200 Peach Street El Dorado, AR 71730
OA-S2 DN
DN
Checked by:
SE STAIR 4 UP
UP
DIRECTOR'S OFFICE
TEAMING
221
220
DIRECTOR'S OFFICE 250
OPEN TO BELOW
Drawn by:
Author
DIRECTOR'S OFFICE
TEAMING
DIRECTOR'S OFFICE
252
251
S-4
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
SECOND FLOOR FURNITURE PLAN
219
CD 1
SECOND FLOOR FURNITURE PLAN 1/8" = 1'-0"
I-202
PRIMARY 12/1/2015 4:46:39 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
DIRECTOR'S OFFICE
MANAGER'S OFFICE
MANAGER'S OFFICE
332
334
333
OPEN WORKSTATION AREA
SR. DIRECTOR'S OFFICE 337
OA-N3
FURNITURE LEGEND
DIRECTOR'S OFFICE
DIRECTOR'S OFFICE
338
331
FURNITURE LAYOUTS: FURNITURE LAYOUTS INDICATE LOCATION AND QUANTITY OF FURNITURE FOR REFERENCE ONLY. ALL FURNITURE TO BE FINIALIZED, SUPPLIED, AND INSTALL BY OWNER.
SR. MANAGER'S OFFICE
DIRECTOR'S OFFICE
SEE SHEET F-100 FOR FURNITURE ANNOTATION AND BLOCKING KEY.
339
330
N.I.C. - INDICATES AREA NOT IN CONTRACT
UP
UP
NW STAIR 1 S-1
NE STAIR 2
DN
S-2
DN
CORRIDOR 3XX
COPY 355
CONFERENCE MECH
MERCHANDISE DISPLAY AREA
WOMENS TOILET 305
REF
352
329
SR. MANAGER'S OFFICE
306
341
CORRIDOR 3XX
COFFEE/ KITCHEN
MENS TOILET
356
ELEC.
304
308
TEAMING
WIRING CLOSET
312
327
VP OFFICE HUDDLE
328
336
OPEN WORKSTATION AREA
GUEST OFFICE 326
OA-E3
FILES/ STORAGE TEAMING
OPEN TO BELOW
MANAGER OFFICE
340
353
313
SR. DIRECTOR'S OFFICE
ATRIUM
OPEN WORKSTATION AREA
CONFERENCE
OA-W3
311
SR. DIRECTOR'S OFFICE
342
345
SR. DIRECTOR'S OFFICE 343
CONFERENCE 325
TEAMING
WIRING CLOSET
MENS TOILET
ELEVATOR 1
ELEVATOR 2
E-1
E-2
DIRECTOR'S OFFICE
309
324 3YY
346
ADMINISTRATIVE ASSISTANT
CORRIDOR
SR. VP OFFICE
344
314
CORRIDOR
ELEC.
3YY
302
MECH
347
TEAMING
303
323
COFFEE WOMENS TOILET
JAN
315
310
300
REF
MANAGER'S OFFICE
COATS
SR. DIRECTOR' S OFFICE
316
322
ENGINEERING CONFERENCE 317
DN
348
COPY DN
349
SE STAIR 4 UP
UP
Checker
MANAGER'S OFFICE
SR. DIRECTOR'S OFFICE
Checked by:
321
350
OPEN WORKSTATION AREA
MANAGER'S OFFICE
OA-S3
320
S-4
Commision #15054.00 200 Peach Street El Dorado, AR 71730
Westlake Reed Leskosky
HUDDLE 318
Murphy USA
VP OFFICE 351
SR. MANAGER'S OFFICE
Author
319
The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
THIRD FLOOR FURNITURE PLAN
Drawn by:
CD 1
03 THIRD FLOOR FURN 1/8" = 1'-0"
I-203
PRIMARY 12/1/2015 4:46:48 PM
Issued / Revised No. Date Description 1 12/01/2015 BID/PERMIT
FURNITURE LEGEND FURNITURE LAYOUTS:
OFFICE 425
VP OFFICE
OFFICE
434
436
FURNITURE LAYOUTS INDICATE LOCATION AND QUANTITY OF FURNITURE FOR REFERENCE ONLY. ALL FURNITURE TO BE FINIALIZED, SUPPLIED, AND INSTALL BY OWNER. SEE SHEET F-100 FOR FURNITURE ANNOTATION AND BLOCKING KEY.
OFFICE 424
OFFICE
N.I.C. - INDICATES AREA NOT IN CONTRACT
FILES/ WORK
433
437
TREASURY 426
NW STAIR 1
NE STAIR 2
CHECK ROOM
S-1
S-2
423
DN
DN
AUDIT CORRIDOR
EXPANSION
427
OFFICE
426A
CONTROLLER
430
428
435
REF
FILE/ WORK
WOMENS TOILET 405
429
COPY TEAMING
MECH
441
471
406
COFFEE/ KITCHEN COMM.
431
407
ELEC.
OFFICE
OUTSIDE AUDITORS
472
422
408
CONFERENCE
OFFICE
OFFICE
OFFICE
442
440
439
438
MENS TOILET 404
CONFERENCE
WIRING CLOSET
444
418
CONFERENCE 421
OFFICE
OFFICE
VP OFFICE
415
445
443
HSSE 420
OFFICE
OFFICE
446
416 OPEN TO BELOW
COPY
OFFICE OF THE CEO
ATRIUM
417
449
OFFICE 447
OFFICE 414
WIRING CLOSET 448
INSURANCE
CONFERENCE
419
411
MENS TOILET 409
CONFERENCE
OFFICE
OFFICE
413
470
469
EXECUTIVE VISITING
ELEVATOR 1
ELEVATOR 2
E-1
E-2
465
COPY
PENTHOUSE STAIR
ELEC.
455
S-6
402
MECH STORAGE
TOILET
KITCHEN
464
454
450
403
UP
WOMENS TOILET
JAN
TOILET
410
400
452
A/V ROOM 451
LEGAL 468
EXECUTIVE
MEETING
462
456
Murphy USA
DN
DN
SE STAIR 4 S-4
CONFERENCE
Checker
463
CONFERENCE 467
459
453
Checked by:
CONFERENCE 458
OFFICE 466
OFFICE
OFFICE
461
460
WET BAR 457
Westlake Reed Leskosky The Hanna Building 1422 Euclid Avenue, Suite 300 PlayhouseSquare Cleveland, Ohio 44115 216.522.1350
FOURTH FLOOR FURNITURE PLAN
Author Drawn by:
EXECUTIVE BOARDROOM
OFFICE
Commision #15054.00 200 Peach Street El Dorado, AR 71730
CD 1
FOURTH FLOOR FURNITURE PLAN 1/8" = 1'-0"
I-204