O A K R I D G E N A T I O N A L LABORATORY operated by
w--
STE
U N I O N CARBIDE CORPORATION for the U. S. ATOMIC ENERGY COMMISSION
ORNL - TM - 3253 0
w
2
DATE
-
-
February 1 0 , 1971
PERIOD BETWEEN EXAMINATION ..--
I@RE PR0CEDUJ.E-3-FOR-THE
,~
U _ . " Y
-I-
-r
AND ULTIMATE . ._...._DISPOSAL n .
".--I.
~
(Phase I11 of Decommissioning P r o g r d
R . H. Guymon
ABSTRACT
T h i s document d e s c r i b e s t h e c o n d i t i o n of t h e MSRE and s p e c i f i e s procedures t o b e followed a f t e r t h e p o s t - o p e r a t i o n examinations and b e f o r e t h e u l t i m a t e d i s p o s a l o f t h e f i s s i l e and r a d i o a c t i v e m a t e r i a l i n t h e r e a c t o r . The f u e l salt w i l l b e k e p t f r o z e n i n t h e s e a l e d d r a i n t a n k s , w i t h i n secondary containment whose o n l y opening i s through f i l t e r s t o a s t a c k . S u r v e i l l a n c e w i l l c o n s i s t of remote monitoring and d a i l y v i s i t s by X-10 p l a n t p e r s o n n e l . P e r s o n n e l a c c e s s w i l l b e c o n t r o l l e d by t h e s e c u r i t y f e n c e around t h e r e a c t o r b u i l d i n g . The MSRE Procedures s p e c i f y remedial a c t i o n s f o r abno-1 c o n d i t i o n s . Also s p e c i f i e d a r e procedures and r e s p o n s i b i l i t i e s f o r maintenance, m o d i f i c a t i o n s , and removal of s u r p l u s equipment.
,
. Keywords: m o l t e n - s a l t r e a c t o r s , MSRE, p r o c e d u r e s , s t o r a g e , s u r v e i l l a n c e , a d m i n i s t r a t i o n , containment, f l o w s h e e t s , maintenance, o p e r a t i o n s , ORNL, p l a n s , t e s t i n g .
NOTICE This document contains information of o preliminary nature and was prepared primarily for internal use a t h e Oak Ridge National Laboratory. It i s subiect to revision or correction and therefore does not represent a final report.
BISTRfBUTION OF THIS DOCUMENT IS UNLIYlTEb
iii
LJ i
Table of Contents Page ~BSTRACT A.
B. C. D.
E.
F. G.
H.
I.
J.
K.
......................... DESCRIPTION AND NORMAL OPERATING CONDITIONS . . . . . . . . . INTRODUCTION
........................ DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. Control-Room Log . . . . . . . . . . . . . . . . . . . . . 2. Periodic Logs . . . . . . . . . . . . . . . . . . . . . . ABNORMAL CONDITIONS ..................... POWER OUTAGES. . . . . . . . . . . . . . . . . . . . . . . . . ANNUUTASKS.. ....................... 1. Recombine Fluorine by Heating t h e Drain Tank . . . . . . . 2. Pressure T e s t o f t h e Reactor and Drain Tank Cells . . . . 3. FD-2 and FP Pressure . . . . . . . . . . . . . . . . . . . 4. Ventilation System . . . . . . . . . . . . . . . . . . . . 5. RC A i r Activity. . . . . . . . . . . . . . . . . . , . . . 6. ~ u m p p u m p s . . . . . . . . . . . . . . . . . . . . . . . . 7. Miscellaneous . . . . . . . . . ‘. . . . . . . . . . . . . MAINTENANCE AND REPAIRS . . . . . . . . . . . . . . . . . . . REMOVAL OF EQUIPMENT OR INSTRUMENTATION . . . . . . . . . . . ACCESSCONTROL. . . ORGANIZATION AND CHANGES . . . . . . . . . . . . . . . . . . . SURVEILLANCE.
REFETBNCES.
...........................
1
1
8 10
10 10
17 25
26
26 28 29 29 30 30
31
34 34
37
38 40
1
c
This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the United States Atomic EnerSy Commission, nor any of their employees, nor m y of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, comgleteness or usefulness of any information, apparatus, ’moduct or process disclosed, or represents that Its me &odd not &fringe privately owned rights.
‘bi 7
I
._ ~
W f B U T l O N OF THIS DOC--
T
IS ZTNL
W
.
A.
INTRODUCTION
The retirement o r decommissioning of t h e MSRE involves s e v e r a l phases. Phase I i s t h e period between t h e end of power operation and t h e postoperation examinations, which is Phase 11. Phase I11 i s t h e i n t e r i m period between t h e completion o f t h e examinations and t h e f i n a l d i s p o s a l which
i s Phase I V . During Phase 111, some of t h e information given i n t h e MSRE Design and Operations Reports (Refs. 1 through 9 ) and t h e f a c i l i t y drawings w i l l s t i l l b e applicable.
Much of t h e equipment w i l l not b e i n s e r v i c e , however,
and most o f t h e procedures which were followed during operation w i l l no longer b e applicable.
This report describes t h e systems which w i l l be
used and s p e c i f i e s t h e normal conditions and s u r v e i l l a n c e required during Phase 111. It a l s o lists t h e more probable abnormal s i t u a t i o n s which could develop and prescribes remedial actions.
The system of access c o n t r o l ,
approvals required f o r maintenance and changes, and r e s p o n s i b i l i t i e s are delineated.
This document supersedes a l l previous operating procedures
f o r t h e MSRE.
B.
DESCRIPTION AND NORMAL OPERATING CONDITIONS
Most of t h e equipment and instrumentation involved during Phase I11 i s shown i n Figure B-1.
Pertinent information on t h e instruments i n
s e r v i c e i s given i n Table B-1.
Plan views of t h e b u i l d i n g showing evacu-
a t i o n routes a r e shown i n Figure B-2.
axe given i n Table B-2. (D-AA-A-40880
The most o f t e n used abbreviations
Master, marked-up,.copies of t h e flowsheets
t o 40890) , t h e instrument application drawings (D-AA-B-40500
t o 40515) and t h e e l e c t r i c a l power d i s t r i b u t i o n drawing (E-20794-ED-153-D)
w i l l be kept up t o date and available i n t h e MSRE c o n t r o l room i n Building 7503.
Another up-to-date
s e t of drawings w i l l be kept i n t h e
outermost room of t h e o f f i c e building (Room 17, Building 7509). About one-half of t h e f u e l s a l t (5,460 l b s ) i s s t o r e d i n FD-1 and t h e o t h e r h a l f (4784 l b s ) i n FD-2.
i
A l l of t h e f l u s h s a l t (9,460 l b s ) i s
,,,
-
2
9' I
I
(3 I
SAMPLER ENRICHER c,
I
ht
'---1
h
I I
r----------
1
I I
1
I
I
I
I ---1 NORTI SERVI
ECTRIC \REA
I I
I
I
I I I
I
I
I I --I
VENT
164
1
I
I
UOUSE
REACTOR
I
h-r'
I
UIGH ACTIVITY ON RM-5658 aU: WILL C W W - S
,-c
I I I
-
AND FROM OTHER H I 8IRE643 AY
SEE D-AA-1-40ab3
FlGlJRE 6-1 5 R E FLOWSHE€T FOR PHASE
m
L.RR
~
Fig. B-1.
S-6.n /
I
MSRE Flowsheet for Phase I11 I
I
I
I
1
Table B-1
No.
Location
Range
NO.
** FE-Sl H20
n-Sl
Stack Pnl.
0-1 in.
LI-RC-C
TR
0-20 i n . H20 LE-RC-C
LI-DTC-AI.
TR.
LI-FSC-A LI-FSC-A
TR
LI-FSC-A
TR TR
*
Primary Element
__
11
LE-DTC-Al
0-52 i n . H20 LELDC-C 11 LE-FSC-A
Variable Monitored
No.
Annunciator Switch No. Setpoint
Stack Flow RC Sump Level DTC Sump Level
DC Sump Level FSC-Sump Level
I1
LE-TC-A
I1
LE-SC-A
SC Sump Level
11
LE-WTC-A
WTC Sump Level
LS-PRS
Pump Room Sump L e v e l
XA-SD-8
LS-PRS
4
---
TC Sump Level
PI-572B
ACR
0-50 pSig
PT-572B
FD-2 Pressure
XA-SD-1
PS-572
PI-589A
ACR
0-50 psig
PT-592B
FP Pressure
XA-SD-2
PS- 589
1.2 psig 40.5 p s i g
PI-927A
Stack Pnl. -8-0 i n . H20 PI-927A
Stack F i l t e r I n l e t Suction
XA-SD-3
PS-927
4-1 i n . H20
PI-RC-A
MCR
-15-50 pSig
RC Pressure
XA-SD-4
PS-RC-1
41 p s i g
RI-565-B
ACR
0-100 mR/hr
RC Air Activity
XA-SD-5
RS-565-B
420 mR/hr
RI-565-C
ACR
XA-SD-5
RS-565-C
420 mR/hr
RI-S1-A
ACR
RI-S1-B
ACR
RI-S1-C
ACR
PT-RC-A
RM-565-B 0-100 mR/hr RM-5654
**** **** ****
*** *** RC Air Activity
RM-Sl-A
Stack B,y a c t i v i t y
XA-SD-6
RS-S1-A
<6000 c/m
RM-Sl-B
Stack u a c t i v i t y
XA-SD-6
RS-S1-B
e6000 c/m
R&SI-C
Stack Iodine Activity
XA-SD-~
RS-S1-C
~ 6 0 0 0c/m
* A l l annunciators repeat a t ORML Central Waste Monitoring F a c i l i t y (Building 3105). ** See c a l i b r a t i o n curve f o r conversion t o ***High a c t i v i t y indication (>20 mR/hr) on ef liot wh e. r RSS-565-B or -C w i l l close HCV-565. **** These a l s o i n d i c a t e as w e l l as annunciate at t h e ORNL
Range switching 1s provided. Monitoring F a c i l i t y (Building 3105).
c
INSTRUMENTATION
__
Read-Out Instrument
oi
Central Waste
W
Table E-1
Instrumentation (continued)
Read-Out Instrument BO.
Location
Range
NO.
0-5000 c p m
RM-7001
RI-7012
Hi Bay Hi Bay
0-25 mR/hr
TR-SD-1-1
ACR
0-1000'F
TR-SD-1-2
ACR
0-1000'F
RM-7012 TE-FD1-19A TE-FD1-5
TR-SD-1-3 ACR
0-1000'F
RI-7001
TR-SD-1-4
ACR
0-1000'F
TR-SD-1-5
ACR
0-1000'F
TR-sD-~-~ ACR
0-1000'F
TR-SD-1-7
ACR
0-1000'F
m-m-1-8
ACR
0-1000'F
TR-SD-1-9
ACR
0-1000'F
TR-SD-1-10 ACR
0-1000'F
TR-SD-1-ll
0-1000'F
*
***#A l l
ACR
*
Primary Element
V a r i a b l e Monitored
NO.
Hi Bay Constant Air Monitor XA-SD-7 Hi Bay Monitron XA-SD-7
-- Probe -- Bottom TE-FDl-15 FD-1 temp. - Lower s i d e TE-FD2-19A FD-2 temp. -- Probe ~ e m 2 - 5 FD-2 temp. -- Bottom ~ ~ 4 ~ 2 - 1FD-2 5 temp. -- Lower s i d e TE-FFT-4 FFT temp. -- Bottom TE-FFT-ll FFT temp. -- Lower Side FFT temp. -- Mid Side TE-FFT-7 TE-DTC-6 DTC temp. -- SE TE-RC-1 RC temp. -- SW
Annunciator Switch no. Setpoint RS-7001
4000 cpm
RS-7012
25 mR/hr
FD.1 temp. FD-1 temp.
annunciators repeat at ORNL Central Waste Monitoring F a c i l i t y (Building 3105).
Range switching is provided. These also indicate as w e l l as annunciate at t h e ORNL Central Waste Monitoring F a c i l f t y (Building 3 0 5 ) .
I
5 ORNL-OWB 74-995
HEALTH PHYSICS
I
-N-
INSTRUMENT
-**a-
SECURITY FENCE
@ TURNSTILE
(OUTBOUND ONLY)
GUARD POST
"2" BUILDING 7509 OFFICE AREA
REMOTE ROOM CONTROL MAINTENANCE ELEVATION 862tt Oin.'"D"
1
ELDG. 7503
- 852-ft
LEVEL
E$E" EOUIPMENT
PLOT PLAN
- M S R E AREA
"F"
ELDG. 7 5 0 3 - 8 4 0 - f t
Fig. B-2.
Ehergency Evacuation Routes
LEVEL
,
I
'
Table B-2 EQUIPMENT AND LOCATION ABBREVIATIONS AB
Auxiliary Board
MB
Main Board
ACB
Auxiliary Charcoal Bed
MCR
Main Control Room
ACR
Auxiliary Control Room
NESA
North E l e c t r i c Service Area
BH
Blower House
PR
Pump Room
CB
Charcoal Bed (main)
PRS
Pump Room Sump
cc
Coolant Cell
RC
Reactor C e l l
CDC
Coolant Drain Cell
RMC
Remote Maintenance P r a c t i c e Cell
CDT
Coolant Drain Tank
sc
Equipment Storage C e l l
CT
Cooling Tower
61
Stack
DC
Decontamination Cell
SESA South E l e c t r i c Service Area
DH
Diesel House
SER
Special Equipment Room
DTC
Drain Tank Cell
SF
Stack Fan
FD
Fuel D r a i n Tank
SFA
Stack F i l t e r ( f a n ) Area
FFT
Fuel Flush Tank
SH
Switch House
FSC
Fuel Storage Cell
ST
Service Tunnel
FST
Fuel Storage Tank
TC
Spare C e l l
HB
High Bay
TR
Transmitter Room
HCP
Heater Control Panel
VH WR WT
Vent House
WTC
Waste Tank C e l l
,
Water Room Liquid Waste Tank
4
7 s t o r e d i n FFT.
The salt i s a t ambient temperature and pressure with all
heaters turned o f f .
The salt fill l i n e s (104, 105, and 106) have been
severed and are blanked i n t h e d r a i n tank c e l l . t r a n s f e r freeze valves (107, 108, and 109).
S a l t i s frozen i n t h e
The equalizer l i n e (521)
between t h e tanks and t h e f u e l c i r c u l a t i n g system has been blanked i n t h e drain Cell.
The helium supply l i n e s (572, 574, 576) a r e capped.
The
vent valves (HCV-573, -575, -577, and -533) a r e open ( s i n c e they a r e f a i l open valves) but HV's-542, vent house a r e closed. tanks.
-52211, -522B, -538B, -57lB, and -561 i n t h e
Thus t h e r e normally i s no purge o r vent f r o m t h e
The drain tanks and t h e f l u s h tank gas spaces a r e interconnected
through t h e vent valves and t h e equalizer valves (HCV-544, -545, -546). The pressure i n t h e tank system i s indicated and annunciated by PIA-572 i n t h e a u x i l i a r y control room.
The drain tank and other temperatures
can be read on TR-SD-1. The f u e l c i r c u l a t i n g system contains only r e s i d u a l amounts of f l u s h salt.
The system w a s opened at t h e r e a c t o r , f u e l pump, heat exchanger,
and l i n e 103.
These openings were sealed i n various ways and were shown
not t o leak excessively a t 5 psig.
Since some of t h e heat exchanger tubes
were cut o u t , t h e main coolant s a l t l i n e s (200 and 201) communicate with t h e f u e l system and were therefore welded shut j u s t outside t h e r e a c t o r cell.
The system i s at ambient temperature and pressure.
The helium
supply l i n e s (516, 592, 593, 596, 589, 599, and 600) a r e capped.
The
main vent l i n e (522) i s closed by HV-522A and t h e upper offgas l i n e (524) i s capped i n t h e Special Equipment Room.
The pressure i s indicated and
annunciated by PIA-589 i n t h e Auxiliary Control Room. The coolant salt (3,575 l b s ) i s i n t h e coolant drain tank, a t ambient temperature and pressure.
Freeze valves 204 and 206 a r e frozen t o separate
it from t h e coolant c i r c u l a t i n g system.
The helium supply valve (HV-
5 U B ) i s closed and t h e vent l i n e i s blanked o f f t o i s o l a t e t h e tank.
The coolant c i r c u l a t i n g system contains only r e s i d u a l amounts of coolant salt. (masking t a p e ) .
It has been opened i n s e v e r a l places and i s l i g h t l y sealed There a r e no helium inputs t o t h e system o r vents from
it.
-6d
The main charcoal beds a r e i s o l a t e d by valves 522B and 557B. a u x i l i a r y charcoal bed i s i s o l a t e d by valves 561 and 5 6 2 ~ .
The
a
U
The r e a c t o r and drain tank c e l l membranes a r e sealed and t h e blocks
are secured.
The v e n t i l a t i o n valves (930B and 955B) a r e closed and locked.
The c e l l s a r e vented t o t h e s t a c k through l i n e 565.
by pressure from a cylinder of nitrogen.) t o r e d by RIA-565 B and C.
(HCV-565 i s kept open
Activity i n t h e l i n e i s moni-
High a c t i v i t y indication on e i t h e r detector
w i l l close HCV-565 and annunciate i n t h e a u x i l i a r y control room.
A l l other
l i n e s and penetrations i n t o t h e c e l l s a r e mechanically sealed. Stack fan SF-1 i s i n s e r v i c e and SF-2 i s i n standby (damper 925 open and 926 closed).
A l l t h r e e s t a c k f i l t e r s a r e i n service.
Most of t h e
building v e n t i l a t i o n flow i s from t h e high bay with smaller amounts from other areas including t h e chemical processing c e l l . bution i s not c r i t i c a l . )
(The r e l a t i v e distri-
The s t a c k flow i s indicated by FI-S1 at t h e stack.
The pressure at t h e inlet t o t h e f i l t e r s is indicated and annunciated by PIA-927A.
The a, B-y, and iodine a c t i v i t i e s i n t h e s t a c k a r e indicated
and annunciated i n t h e a u x i l i a r y control room and a t t h e ORNL Central Waste Monitoring F a c i l i t y (CWMF)
.
A l l water l i n e s t o t h e r e a c t o r and drain tank c e l l s have been disconnected.
The w a t e r l e v e l s i n all c e l l sumps can be checked using t h e bub-
b l e r l e v e l i n d i c a t o r s , but no annunciation is provided.
The waste tank i s
e s s e n t i a l l y empty and can a l s o be checked using a bubbler l e v e l indicator. The pump-room sump, which c o l l e c t s water from t h e f i l t e r p i t , french d r a i n s , e t c . , i s automatically pumped t o t h e drainage d i t c h by t h e sump pumps. High l e v e l i n t h i s sump is annunciated. The f i r e alarm and s p r i n k l e r system is i n se.rvice and maintained by t h e ORNL f i r e department. C.
SURVEILLANCE
Surveillance of t h e MSRE s h a l l be adequate t o prevent t h e development of any condition t h a t would threaten personnel s a f e t y o r t h e continuity of other ORNL a c t i v i t i e s . Radioactive and f i s s i l e materials are s o contained and s i t u a t e d t h a t c r i t i c a l i t y i s prevented and t h e p r o b a b i l i t y of any s i g n i f i c a n t r e l e a s e t o
u=
9 t h e environment i s extremely small.
The p o t e n t i a l s f o r increasing tempera-
t u r e and pressure i n t h e containment o r t h e development of o t h e r potentia l l y damaging conditions a r e l i m i t e d s o t h a t such conditions can arise only slowly, i f at a l l .
Thus t h e continuous presence of personnel at t h e reac-
t o r s i t e i s not required.
Surveillance t h e r e f o r e c o n s i s t s of scheduled
visits f o r data-logging and checking plus t h e continuous monitoring at t h e ORNL Central Waste Monitoring F a c i l i t y of key s i g n a l s f r o m t h e MSRE i n s t r u mentation. Each day a member of t h e ORNL Central Waste Monitoring Group s h a l l e n t e r t h e r e a c t o r b u i l d i n g t o make observations as required on a Daily Log Form.
During t h e l a s t week o f each month a q u a l i f i e d member of t h e Reactor
Division s h a l l make an inspection of t h e r e a c t o r b u i l d i n g , record d a t a , and make checks as required on a Monthly Log Form.
Equipment and instrumenta-
t i o n s h a l l be maintained on a r e g u l a r schedule and as required by personnel of the ORNL Plant and Equipment Division and Instruments and Controls D i v i sion.
When any of a s e l e c t e d l i s t of v a r i a b l e s goes out of limits (prescribed i n Table B-1) alarms occur both i n t h e r e a c t o r b u i l d i n g and at t h e ORNL Central Waste Monitoring F a c i l i t y i n Building 3105.
When an alarm occurs,
one person from t h e group on duty at t h e CWMF s h a l l go t o t h e MSRE s i t e , e n t e r t h e main c o n t r o l room and take appropriate action t o r e s t o r e normal conditions. Corrective actions f o r foreseeable abnormal s i t u a t i o n s a r e prescribed i n Section E of t h e s e Procedures.
I n a d d i t i o n , experienced former members
of t h e MSRE operations s t a f f s h a l l b e designated and a v a i l a b l e on c a l l f o r a s s i s t a n c e i n meeting needs t h a t may a r i s e .
(See Fig. K-1.1
The ORNL P l a n t Protection Division provides p r o t e c t i o n a g a i n s t e n t r y by unauthorized personnel (
-W
Section J) and against f i r e damage.
10
D.
DATA
Control-Room Log
1.
Every s i g n i f i c a n t event o r a c t i o n a f f e c t i n g t h e r e a c t o r s h a l l be recorded i n a journal-type logbook that i s kept i n t h e control room.
Some
items w h i c h s h a l l be included i n t h i s l o g are: Equipment s t a r t e d o r stopped. Valves opened o r closed.
.
Switches o r breakers opened o r closed. Procedures o r p a r t s o f procedures s t a r t e d , worked on pleted.
o r com-'
Changes i n s e t p o i n t s of switches. Annunciations, and action taken. Abnormal conditions o r malfunctioning equipment found. Maintenance and other non-operational jobs done. The person who makes an observation, o r takes action, o r i s i n charge of any Job s h a l l be responsible f o r seeing that an e n t r y i s made.
Log
e n t r i e s s h a l l be s u f f i c i e n t l y descriptive f o r others t o understand and each s h a l l include t i m e , date, and t h e name of the person making the entry
.
Carbon copies of t h e logbook sheets w i l l be removed when t h e monthly l o g i s taken and w i l l be s t o r e d i n a f i l e cabinet i n Room 17, Building
2.
7509.
Periodic Logs The Daily Log includes recording various readings as indicated on
Form D-1.
This form prescribes "Log Limits" and i d e n t i f i e s the appropriate
corrective action i f a variable i s outside these limits.
(Corrective
actions, i d e n t i f i e d on Form D-1 by a l e t t e r , are d e t a i l e d i n Section E of these Procedures. )
The Monthly Log, w h i c h s h a l l b e f i l l e d out during t h e monthly inspection, i s Form D-2.
This form requires reading t h e s a l t tank temperatures, I
t h e w a s t e tank l e v e l and
7
sump l e v e l s .
It a l s o has spaces f o r i n d i c a t i n g
that o t h e r routine monthly t a s k s have been done.
W-
Form D-l DAILY LOG -PHASE III
I 1 i i ! 4 I
*
1
See Section TX-4413
E.
12
v
Form D-l DAILY LOG -PHASE III
.#
1
'Location Description Primary Element
adjustdle #S*
TX-4413
See Section
.
E.,
and will
normally
be set lower than 6000
13
Li
Form D-l DAILY LOG -PHASE III
St See Section TX- 4413
E.
,hd
14 FormD-2 MONTHLYLOG (To be taken during the last week of each month)
I
NOTE: NOTIFY WASTEMONITORINGGROUPBEFORE STARTING What to do if out of Limits
Item
Jan or July
Feb Mar or or AUK Sept
April or act
May June or or Nov Dee
p
Initial
--
Review Daily Logs Review Console Log
-mm
3ecord TR-SD-1 Temps -1 - TE-FDl-19A <200째F (1 2 - TE-FDl-5 !
5- TE-~~2-5 6 - TE-FD2-15 7- TE-FFT-4 8 - TE-FFT-11 9 - TE-FFT-'T LO - TE-DTC-6 Ll - TE-RC-1
'm-4412
I
II II
0 11 1t <150째F 0
c
15 Form D-2 MONTHLYLOG
what.
to do if out of Limits --
--
Q Q Q Q 11
TX- 4412
Jan or July
Feb Mar or or Aug Sept
April or Ott
May June or or Nov Dee
I
em
--
--
--
--
--
16
\
Form D-2 MONTHLYLdG Inspect each of the following areas for hazards Tour the building. Punch~list any repairs or malfunctioning items or abnormal radiation. which are needed. Take cutie pie or chirper on tour. *
North Electric Service f
'Service
Area
Tunnel
Notify key holders (See Section J.) TX- 4412
of abnormal radiation
or contamination
areas.
17
E.
ABNORMAL CONDITIONS
Whenever t h e l o g limits are exceeded o r an annunciation occurs, corrective a c t i o n i s necessary. trouble i s impractical.
To plan i n advance f o r all possible
A n attempt has been made t o a n t i c i p a t e some of
t h e more probable d i f f i c u l t i e s and suggest remedial actions.
"What t o do
i f out of limits" columns have been included i n t h e logs (Forms D-1 and
D-2) and i n t h e ' l i s t of annunciators (Table E-1).
Letters i n these columns
refer t o t h e suggested a c t i o n given i n Table E-2.
Power outages are cov-
ered i n Section F.
18
h,
Table E-1
ANNUNCIATION
What t o Do If Out of L i m i t s
Annunciator No.
Switch No.
XA-SD-1
PS-572
High FD-2 Pressure
G
XA-SD-2
PS-589
High FT Pressure
H
XA-SD-3
PS-927
Low Ventilation Suction
K
XA-SD-4
PS-RC-1
High RC Pressure
F
XA-SD-5
RS-S1-A RS-S1-B
J J
Rs-S1-C
H i Stack Activity ( b y ) H i Stack A c t i v i t y (a) H i Stack A c t i v i t y (Iodine)
XA-SD-6
RS-565B RS-565C
H i RC Air A c t i v i t y H i RC Air A c t i v i t y
I I
XA-SD-7
RS-7001 RS-7012
H i Air A c t i v i t y H i Radiation
L L
XA-SD-8
IS-PRS
H i Pump Room Sump Level
R
*See NOTE:
Cause of Annunciation
J
Table E-2.
Loss of e l e c t r i c a l power w i l l a l s o annunciate a t t h e ORNL Central Waste Monitoring F a c i l i t y (Building 3105).
Table E-2 ABNORMAL CONDITIONS
Variable Out of L i m i t s
Code
Corrective Action
I
W
A
FD-1 Temp
I f TE-FDl-lgA
(TR-SD-1-1) i n d i c a t e s greater than 200°F, other FD-1 temperatures should be checked (TR-SD-1-2 & 3 ) . I f these a r e l e s s than 200°F, n o t i f y t h e MSRE Supervisor on t h e next regular work day. If a l l t h r e e temperatures a r e g r e a t e r than 200°F, n o t i f y him as soon as possible and check t h a t all h e a t e r s are o f f . If TR-SD-1 f a i l s , read t h e temperatures with a portable instrument and have TR-SD-1 repaired on t h e next regular work day.
B
FD-2 Temp
If TE-FD2-lgA (TR-SD-1-4) i n d i c a t e s g r e a t e r than 200°F, other FD-2 .temperatures should be checked (TR-SD-1-5 & 6 ) . If these are less than 2OO0F, n o t i f y t h e MSRE Superv i s o r on t h e next regular work day. I f all t h r e e temperatures a r e greater than 200°F, n o t i f y him as soon as possible and check $hat all h e a t e r s a r e o f f . I f TR-SD-1 f a i l s , read t h e temperatures with a portable instrument and have TR-SD-1 repaired on t h e next regular work day.
C
FFT Temp
I f TE-FFT-4 (TR-SD-1-71 i n d i c a t e s g r e a t e r than 200°F, other f l u s h tank temperatures should be checked (TR-SD-1-8 & 9). I f these are less than 200°F, n o t i f y t h e MSRE Supervisor on t h e next regular work day. I f a l l t h r e e temperatures are g r e a t e r than 200°F, n o t i f y h i m as soon as possible and check t h a t all heaters a r e o f f . If TR-SD-1 fails, read t h e temperatures with a portable instrument and have TR-SD-1 repaired on t h e next regular
D
DTC Temp
, ( TR-SD-L~O) , i n d i c a t e s g r e a t e r than 150°F, other drain tank c e l l temperatures should be checked (Patch panel 208 t o 212). If these are less than 15OoF, n o t i f y t h e MSRE Supervisor on t h e next regular work day. If they a r e g r e a t e r than 15OoF, n o t i f y
20 Table E-2 ABNORMAL CONDITIONS (continued) ~~
Variable Out of L i m i t s
Code ~~
~~
-
Corrective Action
~
D (con't)
!
~
him as soon as possible and check t h a t all i n - c e l l heaters a r e turned n f f . I f TR-SD-1 f a i l s , read t h e temperatures with a portable instrument and have TR-SD-1 repaired on t h e next regular work day.
E
RC Temp
If TE-RC-1 (TR-SD-1-11) i n d i c a t e s g r e a t e r then 150째F, other r e a c t o r c e l l temperatures should be checked. (Patch panel 82 t o 90.) If these are l e s s than 150째F, n o t i f y t h e MSRE supervisor on t h e next regular work day. If they are g r e a t e r than 150째F, n o t i f y him as soon as possible and check t h a t a l l i n - c e l l h e a t e r s a r e turned o f f . If TR-SD-1 f a i l s , read t h e temperatures with a portable instrument and have TR-SD-1 repaired on t h e next regular work day.
F
RC Press.
If PI-RC-A indicates g r e a t e r than 0.5 p s i g o r less than -2 p s i g o r i f XA-SD-4 annunciates, check i n t h e vent house t h a t HCV-565 and V-565A, C , and D a r e open. If n o t , push r e s e t buttons on RE-565 B & C i n t h e control room and open t h e hand valves. If t h e pressure is . s t i l l out of limits and c e l l air a c t i v i t y is normal, vent t h e c e l l by opening V-955 A and B i n t h e s e r v i c e tunnel. After about 30 minutes, close V-955 A and B. Notify t h e MSRE Superv i s o r on t h e next regular work day. If PI-RC-A o r XA-SD-4 f a i l s , have it repaired on t h e next regular work day. If both f a i l , n o t i f y t h e MSRE Supervisor as soon as possible.
G
FD-2 Press.
If PI-572B reaches 2 p s i g o r XA-SD-1 annunciates, vent t h e drain tanks t o t h e stack by opening V-561 and V - 5 6 2 ~i n t h e vent house. When t h e pressure i s 0 t o 1 p s i g , close V-561 and ~-562A. Notify t h e MSRE Supervisor on t h e next regular work day. I f t h e pressure reaches 5 p s i g , n o t i f y t h e MSRE Supervisor as soon as possible. If PI-572B o r XA-SD-1 f a i l s , have it repaired on t h e next regular work day. If both f a i l , n o t i f y t h e MSRE Supervisor as soon as possible.
*
LJ
21 Table E-2 ABNORMAL CONDITIONS ( continued) ~~
Code
H
K
Variable Out of L i m i t s
Corrective Action
FP Press.
I f PI-589A reaches 0.5 p s i g o r i f XA-SD-2 annunciates, vent t h e f u e l system t o t h e s t a c k by opening V-522A, v-561, and V-562~ i n t h e vent house. When t h e pressure i s 0 t o 0 . 1 p s i g , close V-522AY v-561, and V-562A. Notify t h e MSRE Supervisor on t h e next r e g u l a r work day. If t h e pressure reaches 5 p s i g , n o t i f y t h e MSRE Supervisor as soon as possible. If PI-589A o r XA-SD-2 f a i l , have them repaired on t h e next r e g u l a r work day.
RC A c t i v i t y
If RI-565B o r C reach annunciates, ( o r i f c l o s e V-565~ i n t h e t h e MSRE Supervisor work day.
Stack A c t i v i t y
I f RI-S1-A, B y o r C i n t h e a u x i l i a r y c o n t r o l room i n d i c a t e abnormal s t a c k a c t i v i t y , i . e . >1500 c/m, n o t i f y t h e MSRE Supervisor on t h e next r e g u l a r work day. I f any exceed 6000 c/m, n o t i f y him as soon as possible. If any instrument should' f a i l , r e p a i r s should be made as soon as possible.
Ventilation
I f FI-S1 i s less than 0.4 i n . H 2 0 ( - 15,000 cfm) o r i f PI-927A i s l e s s than 1.0 i n . H 2 0 vacuum, o r i f PI-927A annunciates on XA-SD-3, check t h a t one s t a c k fan i s operating properly and t h e r e i s a good flow of a i r i n t o duct 935 i n t h e southeast corner of t h e high bay. If v e n t i l a t i o n i s adequate, n o t i f y t h e MSRE Supervisor on t h e next r e g u l a r work day. If n e i t h e r s t a c k fan i s i n operation, o r if v e n t i l a t i o n flow i s low, start t h e a l t e r n a t e s t a c k fan as follows: Stop both s t a c k fans from t h e c o n t r o l room. Open t h e discharge damper on t h e s t a c k fan t o b e operated (Damper 925 f o r SF #1 - west and damper 926 f o r SF #2 e a s t ) . Close t h e discharge damper
-
20 mR/hr o r i f XA-SD-5 t h e instruments f a i l ) vent house and n o t i f y on t h e next r e g u l a r
f
22
hs
Table E-2 ABNORMAL CONDITIONS (continued)
Code
Variable Out of L i m i t s
K (continued)
L
Personnel Monitors
Corrective Action (926 o r 925) on t h e other s t a c k fan. S t a r t t h e desired s t a c k fan. (It m a y b e necessary t o energize t h e proper breaker i n t h e switch house. This i s G3-24 f o r SF #1and G4-34 f o r SF #2. Notify t h e MSRE Supervisor on t h e next regular work day. I f t h e above does not c o r r e c t t h e d i f f i c u l t y , n o t i f y t h e MSRE Supervisor as soon as possible. I f any of t h e instruments f a i l t o f'unction, have them repaired on t h e next r e g u l a r work day. I f RI-7001 i n d i c a t e s high air a c t i v i t y (>bo00 cpm) o r i f RI-7012 i n d i c a t e s high r a d i a t i o n (>25 mR/hr.) , have Health physics survey t h e area. If abnormal conditions are found,
n o t i f y t h e MSRE Supervisor as soon as possible. I f instrument f a i l u r e occurs, rep a i r s should be made as soon as possible. Notify t h e MSRE Supervisor on the next r e a l m work day. M
WT Level
If WT l e v e l i s g r e a t e r than 100 inches, transf e r t h e contents t o t h e Melton Valley Waste S t a t i o n as follows: C a l l ORNL Waste S t a t i o n (Telephone 3-6234) and r e p o r t volume t o be pumped. When permission t o t r a n s f e r i s obt a i n e d , remove blocks and s e t valves as follows i n t h e Remote Maintenance P r a c t i c e C e l l : Open V-300. Close V-301, V-302, Start V-303, V-3O5Ay V-305BY and V-307. t h e w a s t e pumps. (It may b e necessary t o energize breaker G4-4 i n t h e switch house.) T h r o t t l e V-305A t o give flow acceptable a t Melton Valley Waste S t a t i o n . PI-305 should not exceed 35 psig. When desired amount has been t r a n s f e r r e d , s t o p pump. Close V-300 and 305A and replace blocks on remote maintenance p r a c t i c e c e l l . Record waste tank l e v e l s i n t h e console l o g (before and after t r a n s f e r ) .
hd-
23 Table E-2 ABNORMAL CONDITIONS (continued)
Code
Variable Out of L i m i t s
N
RC Sump
If LI-RC-C i n d i c a t e s a l e v e l g r e a t e r than 15 inches i n t h e r e a c t o r c e l l sump, j e t t h e water t o t h e waste tank as follows: Record LI-RC-C and w a s t e tank l e v e l i n t h e console log. Connect steam t o l i n e 332 on t h e west s i d e of t h e building. Connect instrument a i r o r nitrogen t o t h e valve operators of FCV-333Al and A2 and open them. Open t h e steam supply t o l i n e 332 and j e t t h e sump. When complete, remove steam supply and cap l i n e 332. Remove a i r o r Np supply t o FCV-333Al and A2. Record LI-RC-C and waste tank l e v e l i n t h e console log.
0
DTC sump
If LI-DTC-A1 i n d i c a t e s a l e v e l g r e a t e r than 15 i n . i n t h e drain tank c e l l sump, J e t t h e water t o t h e waste tank as follows: Record LI-DTC-Al and waste tank l e v e l i n t h e console log. Connect steam t o l i n e 342 on t h e west s i d e of t h e building. Connect instrument a i r o r nitrogen t o t h e valve operator of FCV-343Al and A2 and open them. Open t h e steam supply t o l i n e 342 and j e t t h e sump. When complete, remove steam supply and cap l i n e 342. Remove air o r N p supply to F C V - 3 4 W and A 2 . Record LI-DTC-Al and waste tank l e v e l i n t h e console log.
P
DC Sump
If t h e l e v e l i n t h e decontamination c e l l exceeds 1 5 i n . , pump it t o t h e waste tank as
Corrective Action
follows: Record t h e sump l e v e l and t h e w a s t e tank l e v e l i n t h e console log. Remove t h e blocks from t h e remote maintenance p r a c t i c e c e l l . Close V-300, V-302, V-307, and 30%. Open V-303B and V-301. Start waste pump .from RMF'C and pump DC t o WT. Stop pump and close V-303 and V-301. Record DC sump l e v e l , LI-DC and waste tank l e v e l i n t h e console log. '
;W
24 Table E-2
ABNORMAL CONDITIONS (continued) ~~
Code
Variable Out of L i m i t s
Q
Aux. Sumps
Corrective Action If t h e l e v e l i n any o f t h e a u x i l i a r y c e l l sumps exceeds 1 5 i n . , j e t t h e water t o t h e w a s t e tank as follows: Record t h e sump l e v e l and t h e waste tank l e v e l (LI-WT) i n t h e console log. Open proper j e t supply valves ( t h e s e are l o c a t e d i n t h e NE corner of t h e t r a n s m i t t e r room).
Level Element
J e t Supply Valves
Fuel Storage
LE-FSC
V-321, V-311B
Equipment Storage
LE-sc
Waste Tank
LE-WTC
Spare
LE-TC
V-317, V-311B V-315A, V-315B V- 319, V- 311B
Remote Maintenance Practice
None
V-315A, V-323
Cell
When j e t t i n g i s complete, close t h e valves and record t h e sump l e v e l and t h e waste tank l e v e l i n t h e console log.
R
PRS Level
â&#x20AC;&#x2122;
If t h e pump room sump l e v e l annunciates, check t h e pump room t o see i f it i s flooded. (Entrance i s i n t h e SE corner. of t h e high bay.) Do not e n t e r without t h e exhaust fan i n operation and another person on hand f o r emergency. If possible, check t h e f l o a t switches of both sump pumps. If t h e sump cannot be emptied with t h e pumps, t r y j e t t i n g t h e coolant d r a i n c e l l s m p (which connects with t h e pump room) using steam through l i n e s 309 and 310.
25
F.
POWER OUTAGES
A power outage at t h e MSRE should not cause much d i f f i c u l t y and should not be hazardous.
An a l a r m w i l l occur at t h e ORNL Control Waste
Monitoring F a c i l i t y unless they a l s o l o s e power; i n t h a t case no a l a r m
w i l l occur u n t i l t h e i r power t r o u b l e i s corrected. When power i s a v a i l a b l e , a s t a c k fan should be s t a r t e d .
HCV-565
should be opened by pushing t h e r e s e t buttons on RE-565 B and C , and t h e high-bay CAM and monitron should be checked.
A l o g should be taken t o
assure t h a t everything i s within l i m i t s and t h a t nothing appears abnormal i n t h e area.
Check t h a t t h e r e i s no water i n t h e pump room (observe
from 852 l e v e l ) .
Freeze p r o t e c t i o n should be considered i n t h e winter.
The MSRE supervisor should be n o t i f i e d on t h e next regular work day.
ANNUALTASKS
G.
The f u e l and flush salt i n t h e drain tanks w i l l be heated once a year t o recombine fluorine.
An annual check w i l l b e made t o determine t h a t a l l
c
valving and e l e c t r i c a l switches are i n t h e proper position, t h a t standby equipment w i l l operate i f needed and t h a t t h e annunciator and control switches have t h e proper s e t p o i n t s .
The following check lists are used
t o accomplish t h i s .
Init. 1.
Date/Time
Recombine Fluorine by Heating t h e Drain Tank 1.1
-
Close switches 1 7 i n Panel -1-1, s w i t c h e s 1 6 and u i n Panel FD-2-1, and switches 1 6 and 11 i n Panel FFT-1 (North end of 849 l e v e l ) and energize Breaker G5-BB.
-
1.2
Push FD-1-1, FD-2-1, and FFT-1 "ON" buttons and raise o r lower s e t t i n g s t o g e t approximately 9 amps on t h e heaters (HCP-8).
1.3
Open and leave V-561 and 5628 open t o vent t h e drain tanks.
1.4
Record temperatures d a i l y i n Table G l u n t i l t h e salt has been above 300째F f o r a t l e a s t one week (do not exceed 5OOOF).
1.5
Turn h e a t e r s o f f and open switches 1 7 i n Panel FD-1-1, switches 1 - 6 and 11 i n Panel FD-2-1, and switches 1 6 and 11 i n Panel FFT-1 and rack out Breaker G5-BB. Close v-561 and ~-562A.
-
-
1.6 1.7 NOTE:
Record temperatures d a i l y i n Table G l u n t i l temperatures are less than 250째F.
Add helium as necessary through V-518A t o keep FD-1 pressure between 0 and 2 psig. (See G 3 f o r vdving )
.
G-
cd
27 Table G-1
Temperature Readings r
28
LJ Init.
2.
Pressure T e s t of t h e Reactor and Drain Tank C - 1 1 2.1
Connect t h e reference s i d e of t h e hook gage i n t h e t r a n s m i t t e r room t o t h e i n - c e l l reference volume. (Penetration A-27 i n t h e NESA.) Open t h e hook gage equalizer valve.
-
2.2
Connect t h e other s i d e of t h e hook gage t o t h e drain tank c e l l (Penetration A-5 i n t h e NESA).
2.3
Close HCV-565 using handswitch i n t h e control room.
2.4
Connect a portable diesel air compressor t o l i n e 342 at t h e w e s t s i d e o f t h e b u i l d i n g ( 840 l e v e l ) .
2.5
Pressurize t h e c e l l through l i n e 342 t o approximately 6 psig* per PI-RC-A i n t h e c o n t r o l room. As t h e c e l l i s pressurized, note t h e pressure at which PS-RC-1 annunciates on XA-SD-4. psig. If t h e a l a r m does not occur between 0.5 and 1.5, t h e switch should b e reset. Record f i n a l s e t t i n g psig.
-
,
2.6
Disconnect t h e compressor from l i n e 342, cap t h e l i n e and soap check.
2.7
Close t h e hook gage equalizer valve. Record and p l o t t h e hook gage reading and PI-RC-A once per s h i f t u n t i l t h e leak rate i s established (minimum of 48 h r s ) . Acceptable leak rate i s 400 s c f d at 5 psig. U s e t h e following formula f o r calcul a t i n g t h e l e a k rate.
-
AP
L = 1000 t where
2.8
*
= leak rate i n standard cu f t . per day AP = change i n pressure during t e s t i n inches of w a t e r (from t h e hook gage) t = duration of t h e t e s t i n hours. L
When t h e t e s t i s complete, open t h e hook gage equalizer valve.
Do not exceed 10 psig.
-
Date/Time
29
(cd
Init.
3.
2.9
Open HCV-565 and vent t h e c e l l s t o atmospheric pressure.
2.10
Disconnect t h e hook gage and cap t h e l i n e s a t penetrations A-5 and A-27 i n t h e NESA.
FD-2 and FP Pressure
(To b e done a f t e r d r a i n tank temperatures have cooled below 250째F following t h e f l u o r i n e recombination.)
3.1
Connect a nitrogep cylinder with regulator t o
V-518G i n t h e vent house and check t h a t f i t t i n g does not leak. 3.2
Check t h a t t h e a u x i l i a r y charcoal bed i n l e t valve 561 i s closed and V-522B i s closed.
3.3
Open V-522AY and V-518AY B 1 , C 1 , F, and G and p r e s s u r i z e systems u n t i l PS-589 annunciates on 0.6 p s i g on XA-SD-2 p s i g . (Do noi exceed PI-592B.)Adj&t s e t p o i n t i f necessary t o 0.4 t o 0.6 psig. Record f i n a l s e t t i n g psig.
-
4.
3.4
Close V-522A &d p r e s s u r i z e d r a i n tanks u n t i l PS-572 annunciates on XA-SD-1 psig. (Do not exceed 2.5 p s i g on PI-572B.) Reset PS-572 t o 1 . 5 t o 2.5 p s i g i f necessary. Record f i n a l s e t t i n g psig.
3.5
Close v - 5 1 8 ~B1, ~ C 1 , F, and G and remove nitrogen cylinder and cap l i n e a t 5 1 8 ~ .
3.6
Open v-561 and v - 5 6 2 ~ and vent DT's t o atmosp h e r i c pressure.
3.7
Then open V-522A and vent FP t o atmospheric pressure.
3.8
Close V-522AY V-561, and ~-562A.
Ventilation System
4.1
Record FI-SI i n . H20 (should be g r e a t e r than .5 i n . H x P 1 - 9 2 7 A i n . H 2 0 (suction should be more than 1.5 i n . o f water). Record which s t a c k fan i s i n s e r v i c e
Date/Time
W
30
I n i t . Date/Time 4.2
4.3
Stop both stack fans and note pressure a t which PS-927A annunciates on XA-SD-3 i n . H20. If necessary, r e s e t PS-927A t o -0.9 t o -1.1 i n . of water as indicated on PI-927A. Record f i n a l setting i n . H20.
-
Manually switch dampers t o operate a l t e r n a t e s t a c k fan. Damper 925 should be open t o operate SF-1 West. Damper 926 should b e open t o operate SF-2 East.
-
4.4
S t a r t other stack fan and record FI-S1 in. H20 (should be g r e a t e r than .5 i n . H 2 0 ) and PI-927A i n . H20 (suction should be g r e a t e r than -1.5 i n . water). Record which s t a c k f a n i s i n s e r v i c e It may be necessary t o energize t h e proper breaker i n t h e switch house. This i s G3-24 f o r SF #1and G4-34 f o r SF #2.
-
NOTE:
4.5
5.
.
Set up f o r and put SF-1 i n service. breaker G4-34.
Open
-
RC Air Activity
5.1
Check that alarm s e t t i n g s on RS-565B and C a r e 20 mR/hr by pressing t h e alarm buttons. Adjust i f necessary. A d j u s t c a l i b r a t e t o 0.3 mR/hr.
5.2
Have a Health Physicist i n s e r t a source i n l e a d shieldi n g around RE-565B i n t h e vent house and note t h a t XA-SD-5 annunciates and t h a t HCV-565 closes. (Observe valve located below t h e g r a t i n g i n t h e north s i d e of t h e vent house.)
-
5.3
5.4
5.5
6.
Remove source, reset RS-565B i n ACR and note t h a t
HCV-565 opens and XA-SD-5 c l e a r s . Have a Health Physicist i n s e r t a source near ~ and note that XA-SD-5 annunciates and t h a t HCV-565 closes.
~ 5 6 5 ~
Remove source, r e s e t RM-565~ i n ACR and note t h a t HCV-565 opens and XA-SD-5 c l e a r s .
sump Pumps
-
Two people a r e required f o r t h e following. Be Sure t o t u r n on t h e blower and & l o w ’ . t o ’ ~ ’ , f o about r 5 minutes before entering t h e pump room.
-
-
u-
31
Init.
7.
6.1
Add water t o t h e pump room sump. When sump pump "A" s t a r t s , physically hold t h e f l o a t switch on sump pump "A" down.
6.2
Note t h a t sump pump "B" starts and LS-PRS annunciates on XA-SD-8 (before t h e floor i s flooded) s t o p adding water.
6.3
Release both pump f l o a t switches and note t h a t annunciation c l e a r s and both pumps s t o p when sump l e v e l i s normal.
Miscellaneous The following miscellaneous checks should be comp l e t e d annually.
7.1
Check t h a t equipment valves, switches, e t c . as i n d i c a t e d i n Table G-2.
7-2
Check r e s u l t s of annual DOP t e s t o f s t a c k f i l t e r s .
7.3
Review results of monthly s t a c k monitor checks,
7.4
Review r e s u l t s of monthly personnel r a d i a t i o n monitor checks.
7.5
Review l i s t of programmed maintenance being done and r e s u l t s of previous y e a r ' s maintenance work.
are
Date/Time
32 Table G 2 Miscellaneous Equipment Check
33 Table G 2 Miscellaneous Equipment Check ( continued)
Location
What t o Check
Required Condition
Check when Complete
34
H.
LJ
MAINTENANCE AND REPAIRS
Operating equipment which f a i l s should be repaired as soon as possible.
The urgency depends upon t h e consequences.
Table E-2 l i s t s most
of t h e possible process r e p a i r s and d e l i n e a t e s t h e importance of each. Repairs w i l l be done only with t h e approval o f t h e ORNL Central Waste Monitoring Group, t h e MSRE Mdntenance Supervisor, o r t h e MSRE Supervisor ( o r h i s representative).
The person i n i t i a t i n g t h e request f o r r e p a i r s
w i l l be responsible f o r t h e s a f e t y o f personnel and t h e f a c i l i t y . During regular working hours a Punch L i s t form (FORM H-1) w i l l b e
f i l l e a out and given t o t h e Maintenance Supervisor (Fig. K-1) who w i l l expedite t h e r e p a i r s . Any deviation from t h e punch l i s t should be approved by t h e requestor.
When t h e work i s complete, t h e punch l i s t w i l l be re-
turned t o t h e Maintenance Supervisor who w i l l b e responsible f o r e n t e r i n g all d e t a i l s i n t h e console l o g and f i l i n g t h e completed punch l i s t i n
Room 17, Building 7509. On other s h i f t s , t h e ORNL s h i f t supervisor s h a l l arrange t o have t h e r e p a i r s made and s h a l l be responsible f o r g e t t i n g t h e d e t a i l s recorded i n t h e console log. Most of t h e programmed maintenance w i l l b e done during t h e l a s t week of each month when t h e monthly log i s being taken.
Permission m u s t be
obtained f r o m t h e Maintenance Supervisor, t h e MSRE Supervisor, o r h i s r e p r e s e n t a t i v e before doing these.
N o modification w i l l be made t o t h e f a c i l i t y without t h e approval of t h e MSRE Supervisor o r h i s supervisors.
REMOVAL OF EQUIPMENT OR INSTRUMENTATION
I.
Equipment and instrumentation needed f o r t h e i n t e r i m s t o r a g e of t h e f u e l o r f o r t h e f u t u r e t r a n s f e r o r processing of t h e f u e l w i l l b e r e t a i n e d intact.
Other things may be removed i f needed after obtaining t h e approval
of t h e MSRE Surplus Property Custodian, t h e MSRE Supervisor, o r A s s i s t a n t MSRE Supervisor. ORNL-SPP-37).
A l l ORNL procedures w i l l b e s t r i c t l y adhered t o (see
I n addition an MSRE Property Transfer Form 1-1, and Punch
W-
35 Form H-1.
MSRE PUNCH LIST
*
.
To
Priority
Requested by :
Location Equipment, Line No.,
Date
etc.
Description of Work t o be Done:
Precautions : L
Estimated Cost: Approval to proceed:
De scribe work done i f d i f f e r e n t from above :
Job Canpleted and Accepted by:
TX-4410
Date:
Form 1-1.
MSRE SURPLUS EQUIPMENT TRANSFER
Item:
Tag No.
Quantity and Units: Brief Description:
~~
~
Location at MSRE: Property No. : XRequested by: For use in:
Date : MSRP;
Other (specify)
Charge removal costs to:
When needed:
Trans fer approved by :
Date :
Item received by:
Date :
m-4411
37
hr L i s t , Form H-1,
w i l l be f i l l e d out f o r each i t e m o r group of items re-
A f i l e of t h e s e w i l l be maintained i n Room
moved.
17, Building 7509.
If s p e c i a l precautions a r e necessary, these should b e described f u l l y
on t h e Punch L i s t . J.
ACCESS CONTROL
A s indicated i n Fig. B-2, an %foot l i g h t e d s e c u r i t y fence completely
encloses a compact area immediately surrounding t h e MSRE buildings.
Two
gates ir+ t h e fence (North and West Gates) open onto Melton Valley Drive
( a road posted as "Official U s e Only").
The other two gates and t h e o f f i c e
building door a r e i n s i d e t h e controlled-access HFIR-TRU-TURF area.
All
four gates and t h e o f f i c e door w i l l normally b e kept locked. On t h e o f f i c e door and on each of t h e four gates i s a sign of t h e form indicated below, where t h e blanks contain t h e names and phone nuuibers of (1) t h e MSRE Superv i s o r , ( 2 ) t h e Assistant MSRE Supervisor, (3) t h e MSRP Associate Direct&, - -_
__ ____
J
1
CONTROLLED ACCESS AREA DO NOT ENTER WITHOUT PERMESSION t
Persons Authorized t o Give Permission:
I !
i Normal entrance t o t h e MSRE.Area w i l l . on t h e HFIR Access Road, Gate o r t h e South Gate.
en through e i t h e r
he guard gate f f i c e door, t h e E a s t
Keys t o t h e door and t h e s e two gates w i l l be is-
sued t o a l i m i t e d nuniber of people, including t h e MSRP Associate Director, t h e MSRE Supervisor, t h e MSRE Surplus Property Custodian, t h e Assistant
MSRE Supervisor, t h e MSRE Maintenance Supervisor, t h e ORNL Waste Monitoring Group, and t h e ORNL S h i f t Supervisors.
38 The North and West gates w i l l have security-type locks which are controlled by t h e ORNL Guard Department.
Only a l i m i t e d number of people
w i l l be authorized t o have t h e Guard Department open these.
These w i l l
include t h e MSRP Associate Director,' t h e MSRE Supervisor, t h e MSRE Asst. Supervisor, and t h e ORNL Shift Supervisors.
These gates w i l l not be l e f t
open without a guard i n attendance. There w i l l be r a d i a t i o n and contamination outside of t h e containment cells.
Where required, Radiation and Contamination Zones w i l l be i d e n t i -
f i e d and protection provided as prescribed by ORNL procedures.
Monthly
r a d i a t i o n and s a f e t y surveys w i l l b e made t o assure t h a t no inadequately guarded hazards exist.
Those persons having keys w i l l b e advised of any
l i m i t a t i o n s on use of t h e a r e a , and it w i l l b e t h e i r r e s p o n s i b i l i t y t o
so advise anyone t h a t they admit t o t h e area.
K.
ORGANIZATION AND CHANGES
The organization chart f o r t h e MSRE during Phase I11 i s s h m 4n Fig. K-1.
The MSRE supervisor has t h e prime r e s p o n s i b i l i t y f o r t h e area.
H e must approve of any changes i n t h e procedures o r modification of t h e facility.
A master up-to-date
copy of the procedures w i l l b e kept i n
Room 17, Building 7509. A l l changes w i l l b e i n i t i a l e d and dated.
I f sig-
n i f i c a n t modifications are needed, others i n t h e MSRP p r o j e c t w i l l be consulted.
39 MSRP Director
Associate MSRP Director
P. N. Haubenreich MSRE Supervisor
R. H. Guymon
..
Ass ist ant MSRE Supervisor A. I. Krakoviak
A d v i s ors
(former MSRE s t a f f ) General
Surveillance L. C. Lasher W. T. Newton
S h i f t Operators
J. R. P. A.
L. H. H. I.
Crowley Guymon Harley Krakoviak
Electrical T. L, Hudson
Maintenance
Mechanical
*
H. G. Kern
H. E. F e l t s C. T. Carney
M. Richardson R. S. Jackson
Instruments J. L. Redford R. W. Tucker
P a r t s and Supplies
L. P. Pugh
'bit
Remote Maintenance
*
MSRE Maintenance Supervisor Fig. K-1.
J. R. Shugart
MSRE Organization Chart (January, 1971)
40
REFERENCES
1. R. C. Robertson, MSRE Design and Operations Report, P a r t I , Description of Reactor Design, ORNL-TM-728 (Jan. 1965).
2. J. R. Tallackson, MSRE Design and Operations Report, Part 11, Nuclear and Process Instrumentation, ORNL-TM-729 (Feb. 1968).
3. J. R. Engel, B. E. Prince, and H. C. Claiborne, MSRE Design and Operations Report, P a r t 111, Nuclear Analysis, ORNLTM-730 (Feb. 1964). S. E. Beall, P. N. Haubenreich, R. B. Lindauer, and J. R. 4. Tallackson, MSRE Design and Operations Report, P a r t V, Reactor Safety Analysis Report, ORNL-TM-732 (Aug. 1964).
5. P. N. Haubenreich, J. R. Ehgel, C. H. Gabbard, R. H. Guymon, and Operations Report, P a r t V-A, Safety and B. E. Prince, MSRE Desi Analysis of Operation with g3U, ORNL-TM-2111 (Feb. 1968). I I
R . B. Lindauer, MSRE Design and Operations Report, P a r t V I I , 6. Fuel Handling and Processing Plant, ORNCTM-907 ( M a y 1965).
7. R. H. Guymon, MSRE Design and Operations Report, Part V I I I , Operating Procedures, ORNL!CM-908 (Jan. 1966).
8. A . N. Smith, MSRE Design and Operations Report, P a r t I X , Safety Procedures and Emergency Plans, ORNL-TM-909 (June 1965). 9.
E. C. Hise and R. Blumberg, MSRE Design and Operations Report,
Part X, Maintenance Equipment and Procedures, ORNLTM-910 (June 1968).
41
ORNL-TM-3253 I n t e r n a l Distribution 1. R. G. 2. J. L. 3. T. A. 4. C. F. 5. S. E. 6. E. S. 7. E. G. 8. G. E. 9. R. B. 10. W. B. 11. J. L. 12. J. R. 13. S. J. 14. W. P. 15. J. R. 16. D. E. 17. L. M. 18. A. P. 19. W. R. 20. A. G. 21-30. R. H. 31. P. H. 32. P. N. 33. P. W. 34. H. W. 35. T. L. 36. R. S. 37. J. E. 38. S. I. 39. P. R. 40. J. J.
Affel Anderson Arehart Baes Beall Bettis Bohlmann Boyd Briggs Cottrell Crowley Distefano Ditto Eatherly Engel Ferguson Ferris Fraas Grimes Grindell Guymon Harley Haubenreich Hembree, Jr. Hoffman Hudson Jackson Kahn Kaplan Kasten Keyes 41. A. I. JSrakoviak 42. K e r m i t Laughon, AEC-OSR 43-45. L. C. Lasher 46. B. Lieberman 47 M. I. Lundin 48. R. N. Lyon 9
49 50
51 52
53. 54-55 56 57 58. 59 60. 61. 62. 63. 64. 65-67. 68. 69 70
71
72 73 74. 75. 76. 9
77.
78. 79. 80. 81. 82.
G. MacPherson E. MacPherson E. McCoy W. Magnuson C. McCurdy W. McIntosh, AEC-Washington E. McNeese A. J. Miller A. S. Meyer R. L. Moore E. L. Nicholson A. M. Perry L. P. Pugh J. L. Redford M. Richardson M. W. Rosenthal H. M. Roth, AEC-OR0 A. W. Savolainen R . W. Schaich Dunlap Scott M. Shaw, AEC-Washington J. R . Shugart M. J. Skinner W. L. Smalley, AEC-OR0 I. Spiewak D. A. Sundberg R. E. Thoma D. B. Trauger R. W. Tucker B. T. Walters G. M. Matson
H. R. H. D. H. T. L.
83.
J. R. W e i r
84. 85. 86. 87.
M. E. Whatley J. C. White G. D. Whitman Gale Young
88-89. Central Research Library 90.
Y-12 Document Reference Section
91-93. Laboratory Records Department 94. Laboratory Records Department (RC) External D i s t r i b u t i o n
95-96. 97 93.
99. -
Division of Technical Information Extension (DTIE) Laboratory and University Division, (ORO) A. Houtzeel, 176 Second Avenue, Waltham, Mass. 02154 R. C. S t e f f y , Jr., 303 Power Building, Chattanooga, Tenn. 37401