Air Sampling, Monitoring, Treatment & Filtration Vol. 5
SAMPLING
MONITORING FILTRATION TREATMENT
V O L . 5
Gilian® BDX-II Abatement Personal Air Sampling Pump
The Gilian® BDX-II is designed specifically for asbestos and lead abatement applications when constant flow is not required. The built-in rotameter displays flow rates over the entire flow range of 0.5 - 3.0 LPM and an electronic flow control adjustment enables parts to last longer so maintenance is minimized. Sealed flow adjustment and on/off switch protects the Gilian® BDX-II from moisture, dust and fibers.
Features
• Flow rate: 500 - 3,000 cc/min (total)
• Built-in rotameter
• Will operate 10 hours at 2.0 LPM with inlet pressure of 20"
• Rechargeable NiMH battery pack
• Certifications: Not Intrinsic Safe
GIL-801863-171-1201 Gilian® BDX-II Starter Kit
GIL-801863-171-KIT Gilian® BDX-II 5-Pump Kit With 5-Single Unit Chargers
GIL-801863-171-KIT5 Gilian® BDX-II 5-Pump Kit With Gilian® 5-Station Charger
GIL-801863-171Z-KIT5 Gilian® BDX-II 5-Pump Kit With Zefon® 5-Station Charger
- 3,000 cc/min 120V
- 3,000 cc/min
GIL-800511 17.5" x 13" x 7" Carrying Case - -
Starter Kit Includes
• Gilian® BDX-II pump
• 36" tubing
• Clip assembly
• Reversible screwdriver
• Single unit charger
• User manual
5-Pump Kit Includes
• (5) Gilian® BDX-II pumps
• (5) Pieces of 36" tubing
• (5) Clip assemblies
• (5) Reversible screwdrivers
• (5) Single unit chargers or (1) Gilian® 5-station charger or (1) Zefon® 5-station charger
• (5) User manuals
• Heavy-duty foam lined carrying case
Differences Between Basic, Clock & Programmable Models
• The Basic model is straight-forward and easy to use.
• Clock models provide an elapsed-time clock display.
• Programmable models enable a timer which can start or stop the pump at preset time intervals or program a delayed start.
Gilian® LFS-113 Compact, Pocket-Sized, Personal Low Flow Air Sampling Pump
The Gilian® LFS-113 is designed for flow rates between 1 - 350 cc/min, perfect for very low flow application sampling with sorbent tubes. Offers two user selectable sampling modes; the constant flow control mode holds the flow within ±5% of the set flow while the constant pressure control mode (multi-flow) allows multiple samples to be taken simultaneously through the use of a multi-flow manifold. No other pocket-sized pump matches the wide flow range and high back-pressure capability of the Gilian® LFS-113.
Features
• Flow rate: 1 - 350 cc/min (total)
• Dual mode automatic constant flow or constant pressure control
The Gilian® GilAir-3 and Gilian® GilAir-5 pumps are suitable not only for conventional pull-through sampling media but also for bag sampling and other pressure applications. These 3 and 5 LPM air sampling pumps have automatic constant flow compensation, assuring sampling is maintained within ±5% of the initial set point, even with varying back-pressures from flow restrictions or buildup of material on the filter.
Features
• Flow rate:
Gilian® GilAir-3: 1- 3,000 cc/min (total)
Gilian® GilAir-5: 1- 5,000 cc/min (total)
• Optional low flow modules
• Flow fault & test indicators
• External filter housing
• Rechargeable NiMH battery pack
• Certifications: UL - Intrinsic Safe
GIL-800485-171-1201
GIL-800508-171-1205
GIL-800884-171-1201
GIL-800884-171-1205
Need Help Deciding On A Pump?
1. What flow rate do you require?
2. What sampling method are you using?
Answer the following questions to help narrow it down. 4. Will you need a calibrator? 5. Extra bells and whistles? • Data logging
• Bags (need an exhaust port)
• Tubes
• Cassettes
3. What gas (or gases) are you sampling for?
Starter Kit Includes • Gilian® GilAir-3 or Gilian® GilAir-5 pump • 36" tubing • Air boss kit
• Filter cassette holder
• Reversible screwdriver
• Single unit charger
• User manual
5-Pump Kit Includes
• (5) Gilian® GilAir-3 or Gilian® GilAir-5 pumps
• (5) Pieces of 36" tubing
• (5) Air boss kit
• (5) Filter cassette holder
• (5) Reversible screwdriver
• 5-Unit charger
• (5) User manual
• Carrying case
Gilian® GilAir® Plus Personal Air Sampling Pump
The Gilian® GilAir® Plus is the world’s most capable air sampling pump now with 3 new technologies such as Motion Detection, BluetoothTM Connectivity and the CONNECT Mobile App!
Three models to choose from; the basic model, the datalogging pump (DL) model and the standard temperature and pressure (STP) model.
Features
• Flow rate: 1 - 5,100 cc/min (total)
• Flow modes: constant flow or high and low flow constant pressure
• QuadModeSM air sampling technology
• Selectable automatic fault recovery
• SmartCalSM automatic calibration
• High back pressure capability
• Temperature & pressure compensation
• Rechargeable NiMH battery pack
• Certifications: EN 1232 Compliant, ISO 13137:2013 Compliant, Intrinsic Safe, US/Canada NRTL (FM), ATEX, CE Applicable Directives
Starter Kit Includes
• Gilian® GilAir® Plus pump
• Tubing
• Filter cassette holder
• Charcoal tube holder
• 2 mm hex key
• Charging dock with power adapter
• User manual
• Single unit carrying case
• Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software
5-Pump Kit Includes
• (5) Gilian® GilAir® Plus pumps
• (5) Pieces of tubing
• (5) Filter cassette holders
• (5) Charcoal tube holders
• (5) 2 mm hex keys
• 5-Unit power station
• (5) User manuals
• 5-Unit carrying case
• Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software
Differences Between Basic, Data Logging, & STP Models
• The basic model is straight forward and easy to use.
• The data logging model provides additional advanced program functions and allows data logging and transferring of data to a PC. Also available with BluetoothTM option.
• The STP model refers to standard temperature and pressure. These models correct the display flow rate and air volume to standard conditions of temperature and pressure. Also available with BluetoothTM option.
High Efficiency Air Sampling Pumps
Gilian® Power Series Personal Air Sampling Pumps
The Gilian® Power Series is the industry leader in back pressure performance, reliability and ease-of-use. They also provide automatic constant flow controls and the Gilian® 5000 has an optional adapter module, which can handle lower flows under constant pressure control, such as required for multi-flow sorbent sampling.
5-Pump Kit Includes Model Gilian® 800i Gilian® 5000
Includes • (5) Gilian® 800i pumps
• (5) Pieces of 1/4" x 36" tubing
• 5-Unit power station
• (5) User manuals • Carrying case
• (5) Gilian® 5000 pumps
• (5) Filter cassette holders • 5-Unit power station • (5) User manuals • Carrying case
10i
Gilian® 10i pump
3/8" x 36" tubing
Single unit charger
User manual
10i
• (5) Gilian® 10i pumps
• (5) Pieces of 3/8" x 36" tubing • 5-Unit power station
• (5) User manuals • Carrying case
12
Gilian® 12 pump • 3/8" x 36" tubing
Single unit charger
User manual
12
• (5) Gilian® 12 pumps
• (5) Pieces of 3/8" x 36" tubing
• 5-Unit power station
• (5) User manuals
• Carrying case
Gilian®
Gilian®
Gilian®
Gilian® AirCon-2 Portable High Volume Constant Flow Area Air Sampling Pump
The Gilian® AirCon-2 sampler is a high volume unit with an extended flow range, designed for collecting particulate in a given plant area. It is ideal for asbestos background and clearance sampling following NIOSH, OSHA or EPA methodology and for ambient dust monitoring.
Features
• Flow rate: 2 - 30 LPM (total)
• Fully programmable
• Touchpad & LCD display
• Instant fault function
• Instant pressure check
• Operates off either AC or battery power
• Certifications: Not Instrisic Safe
Includes
• Gilian® AirCon-2 pump
• Hose
• Sampling mast
• Support tip
• User manual
GIL-801012-100 Gilian® Aircon-2 DC Programmable Area Air Sampling Pump Only
GIL-801000-2 Power Module 120V/230V/DC With 120V Cord -
GIL-801001 Lead Acid Gel 4-Hour Battery Pack Requires Power Module (GIL-80100-2) To Charge (Note: May Stack (2) For 8-Hour Operation)
GIL-801171-1 22'' x 16'' x 8'' Wheeled Carrying Case For AirCon-2
Zefon® Escort® LC Personal Air Sampling Pump
The Zefon® Escort® LC air sampling pump can be used with a variety of personal and area sampling devices to collect such airborne contaminants as asbestos fibers, toxic gases, vapors, particulates, fumes and mists. It can also be used to sample silica dust, coal dust and organic vapors.
Features
• Flow range: 0.5 - 3 LPM (total)
• Inlet filter traps particulate matter
• Separate LEDs indicate pump operation and low battery
• Stainless steel-filled plastic case provides EMI/RFI protection
• Rechargeable NiMH battery pack
• Certifications: UL Approved as Intrinsically Safe for use in Hazardous Locations, Class I, Groups A, B, C, D; Class II, Groups E, F and G; Class III, Division I Locations
ZE-811741 Protective Leather Holster Case
Personal Pump Accessories
Please refer to page 28 for more information.
Includes
• Escort® LC pump
• Sampling line
• 120V charger
• User manual
5-Pump Kit Includes
• (5) Escort® LC pumps
• (5) Sampling lines
• 5-Unit charger
• User manual
• Carrying case
Sampling Line with Tube Clip ZE-456226
Zefon® Escort ELF® Personal Air Sampling Pump
The Zefon® Escort ELF® air sampling pump features a state of the art electronic laminar flow sensor to provide a constant flow control with ± 2.5% regulation of flow rate from 1 - 3 LPM with automatic compensation for changes in battery voltage, temperature, altitude, and sample load. An internal secondary standard calibrates the pump continuously and needs to be checked against a primary standard only once per month (or every 200 hours for coal mine dust sampling).
Features
• Flow rate: 0.5 - 3 LPM (total)
• Patented electronic laminar flow control
• Inlet filter traps moisture and particular matter
• Stainless steel-filled plastic case provides EMI/RFI protection
• Rated IP65 for resistance to water and dust ingress
• Flow fault indicator shows any sample inlet blockage
• Run/Hold feature allows "time out" during sampling process
• Elapsed time readout and low-battery warning
• Low flow and dual tube sampling available with Zefon® Gemini Twin-Port Sampler
• Rechargeable NiMH battery pack
• Certifications: NIOSH, MSHA, UL, ATEX specific models only
Includes
• Zefon® Escort ELF® pump
• Sampling line
• 120V charger
• User manual
5-Pump Kit Includes
• (5) Zefon® Escort ELF® pumps
• (5) Sampling lines
• 5-Unit charger
• User manual
• Carrying case
* 240V also available
Buck Libra™ L-4 Abatement Personal Air Sampling Pump
The Buck Libra™ L-4 is designed for sampling of asbestos, lead, and other airborne contaminates. This pump is used to draw air contaminants in through a sampling media such as 25 and 37 mm filter cassettes which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Low flows from 5 - 800 cc/min can be obtained using the optional Adjustable Universal Low Flow Holder.
• High impact steel fiber filled Lexan case, antistatic and RFI shielded
• "Auto-Restart" within one minute of a flow fault
• High backpressure capable for 25 mm 0.45 μm asbestos filters
• Built-in washable stainless steel 100 μm filter for economy of use
• Stainless steel belt clip with built-in tripod connector
• Rechargeable NiMH battery pack
• Certifications: CE EMC Directive (EMCD) 89/336/EEC
Sarter Kit Includes
• Buck Libra™ L-4 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Single pack NiMH battery
• 120V charger
• User manual
5-Pump Kit Includes
• (5) Buck Libra™ L-4 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• (5) Single pack NiMH batteries
• QuickFive™ charger 100-240V
• (2) User manuals
• Pelican carrying case model 1500
Buck Libra Plus™ Series Personal Air Sampling Pump
The Buck Libra Plus™ is designed for sampling of asbestos, lead, and other airborne contaminates. These pumps display flow rate, elapsed time and accumulated volume of the sample.
The Buck Libra Plus™ model LP-1 and LP-5 is used to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes whereas the Buck Libra Plus™ model LP-7, LP-12 and LP-20 can also use 47 mm filter cassettes; which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc.
• Displays: elapsed time, accumulated volume and flow rate
• "Auto-Restart" within one minute of a flow fault
• High backpressure capable for 25 mm 0.45 μm asbestos filters
• Built-in washable stainless steel 100 μm filter for economy of use
• Stainless steel belt clip with built-in tripod connector
• Rechargeable NiMH battery pack
• Certifications: CE EMC Directive (EMCD) 89/336/EEC
Includes • Buck Libra Plus™ LP-1, LP-5 or LP-7 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Non-adjustable tube holder
• Single pack NiMH battery
• Standard 120V battery charger
• User manual
5-Pump Kit Includes
Model Buck Libra Plus™ LP-1, LP-5 & LP-7
Includes • (5) Buck Libra Plus™ LP-1, LP-5 or LP-7 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• Non-adjustable tube holder
• (5) Single pack NiMH batteries
• Quick(5)™ charger 100-240V
• (2) User manuals
• Pelican carrying case model 1500
• Buck Libra Plus™ LP-12 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Non-adjustable tube holder
• Triple pack NiMH battery
• Standard 120V battery charger
• User manual
Buck Libra Plus™ LP-12
• (5) Buck Libra Plus™ LP-12 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• Non-adjustable tube holder
• (5) Triple pack NiMH batteries
• Quick(5)™ charger 100-240V
• (2) User manuals
• Pelican carrying case model 1500
• Buck Libra Plus™ LP-20 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Non-adjustable tube holder
• Triple pack NiMH battery
• Standard 120V battery charger
• User manual
• (5) Buck Libra Plus™ LP-20 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• Non-adjustable tube holder
• (5) Triple pack NiMH batteries
• Quick(5)™ charger 100-240V
• (2) User manuals
• Pelican carrying case model 1600
Buck Elite™ Personal Air Sampling Pump
The Buck Elite™ series personal air sampling pump draws air contaminants in through a sampling media such as sorbent tubes, bubble impingers, long duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 0.6 LPM. Low flows from 5 - 99 cc/min can be obtained using the optional Low Flow Holder.
• Capable for data logging and programmable for multiple "Start/ Stop" and duration sampling
• Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case
• Exclusive electronic circuit board for constant flow control
• "Auto-Restart” within one minute of a flow fault
• High backpressure compensation up to 36” of w.c. @ 300 cc/min
• Flow compensation for filter plugging and battery voltage
• Key pad lock system
• Stainless steel belt clip with built-in tripod connector
• Rechargeable NiMH battery pack
• Certifications: CE EMC Directive (EMCD) 89/336/EEC
Starter Kit Includes Model Buck Elite™-1
Includes • Buck Elite™-1 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Non-Adjustable Low Flow Holder
• Single pack NiMH battery
• Standard 120V charger
• User manual
5-Pump Kit Includes
Model Buck Elite™-1
Includes
• (5) Buck Elite™-1 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• (5) Non-Adjustable Low Flow Holders
• (5) Single pack NiMH batteries
• Quick(5)™ 100-240V charger
• (2) User manuals
• Pelican carrying case model 1500
• Buck Elite™-5 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Single pack NiMH battery
• Standard 120V charger
• User manual
• Buck Elite™-12 pump
• 3 ft of vinyl hose
• Luer hose adapter
• Shirt/hose clip
• Triple pack NiMH battery
• Standard 120V charger
• User manual
Buck Elite™-5
• (5) Buck Elite™-5 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• (5) Single pack NiMH batteries
• Quick(5)™ 100-240V charger
• (2) User manuals
• Pelican carrying case model 1500
Buck Elite™-12
• (5) Buck Elite™-12 pumps
• (5) Pieces of 3 ft of vinyl hose
• (5) Luer hose adapters
• (5) Shirt/hose clips
• (5) Triple pack NiMH batteries
• Quick(5)™ 100-240V charger
• (2) User manuals
• Pelican carrying case model 1600
Buck Allin™ & Buck Allin™ Plus Intrinsically Safe Personal Low Flow Air Sampling Pump
The Buck Allin™ & Buck Allin™ Plus series is a personal air sampler suitable for use in locations where flammable gases, vapors, dust, fibers or flying’s are present. The purpose of this pump is to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes, bubble impingers, long-duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 5.0 LPM. Low flows from 5 - 799 cc/min can be obtained using the optional Low Flow Holder.
The Zefon® 23 stroke High Volume Diaphragm area sampling pump is an economical workhorses with a flow range of 3 - 14 LPM. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes.
Includes
• Zefon® High Volume Diaphragm pump with locking flow control valve
• 10 ft tubing
• Hose barb
• On/Off switch
2-Pump Kit Includes
• (2) Zefon® High Volume Diaphragm pumps with locking flow control valves
• (2) pieces of 10 ft tubing
• (2) Hose barbs
• (2) On/Off switches
• (2) Tripod stands
• Heavy duty carrying case Part
ZE-ZTHV01 Zefon® High Volume Diaphragm Pump
ZE-ZTHV01-KIT Zefon® High Volume Diaphragm 2-Pump Kit
ZE-195380 1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter
ZE-195505 3 - 30 LPM Zefon® Non-Adjustable High Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter
CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft
EMS-200550 Premium Telescopic Sampling Tripod Stand
ZE-ZTHV00-KCASE Carrying Case For ZTHV01 Pumps (Holds (2) ZTHV01 Pumps, (2) Stands & Tubing)
*220V also available
*Please refer to page 27 for area pump replacement parts and area pump accessories
New! Now with internal filter/muffler.
No more glass muffler jars!
Zefon® High Volume Rotary Vane Sampling Pump
The Zefon® High Volume Rotary Vane pump is an economical alternative to the Gast brand Rotary Vane pumps with a flow range of 0 - 30 LPM. The workhorses are heavy duty with a 1/10 hp motor that can be used for almost all sampling applications. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes along with all viable impactors (ex: Andersen style impactor).
Flow Rates
PCM cassette: 3 - 15 LPM
TEM cassette: 3 - 10 LPM
Air-O-Cell® cassette: 15 LPM
Viable Impactor: 28.3 LPM
Includes • Zefon® High Volume Rotary Vane pump with flow control valve
• 2 1/4" I.D. tubing set
• On/Off switch
ZE-ZHV00 Zefon® High Volume Rotary Vane Pump
ZE- ZHV00-KIT Zefon® High Volume Rotary Vane 2-Pump Kit
2-Pump Kit Includes
• (2) Zefon® High Volume Rotary Vane pumps with flow control valves
ZE-195380 1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter
ZE-195505
Includes: Hose Barb, Tygon® Tubing & Luer Adapter
3 - 30 LPM Non-Adjustable High Flow Rotameter
Includes: Hose Barb, Tygon® Tubing & Luer Adapter
CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft
EMS-200550 Premium Telescopic Sampling Tripod Stand
ZE-ZHV00-KCASE Carrying Case For ZHV00 Pumps (Holds (2) ZHV00 Pumps, (2) Stands & Tubing)
*220V
*Please refer to page 29 for area pump replacement parts and area pump accessories
The Zefon® Field Rotameters are a low cost way to measure airflow in air sampling applications. They feature a durable acrylic housing with direct reading scales printed on them. Available in three different flow ranges covering a range of 0.2 through 30 LPM. Operation and maintenance are very simple; only a few common sense precautions must be observed to assure long, trouble-free service.
Features
• Scales are large (average 4" length) and easy to read
• The direct reading scales are hot stamped into the plastic and will not wear off
• Mid-range calibration is established with a master flowmeter, providing an accuracy of ±3% Part Number
ZE-116116
® Non-Adjustable Low Flow Field Rotameter
ZE-195380 Zefon® Non-Adjustable Medium Flow Field Rotameter
ZE-195505
- 4 LPM
- 20 LPM
® Non-Adjustable High Flow Field Rotameter 3 - 30 LPM
Includes
• Zefon® Non-Adjustable Field Rotameter (low, medium or high)
• Tygon® tubing
• Hose barb
• Luer adapter
Accurate, Reliable & Portable Primary Calibrators for Fast Calibration of Air Sampling Pumps!
Defender 500 Series
Defender 510
Volumetric Primary Flow Standard
Defender 520
Enhanced Volumetric Primary Flow Standard
Defender 530+
Standardized & Volumetric Primary Flow Standard
Instantly calibrate your air samplers using Quick Start - there is no preparation involved, no messy soap bubble solutions. Alternatively, set your Defender to take hands-free, continuous measurements while you quickly set the flow rate on your pumps. Defender’s many user-selectable options makes customizing your calibrations easy, giving you exactly what you need in the format you prefer. All you have to do is choose between the 510, the 520 or the 530.
5 - 500 cc/min BIO-200-510M: 50 - 5,000 cc/min
BIO-200-510H: 300 - 30,000 cc/min
User Selectable Measurement Units Volumetric ml/min,
PSI, kPa mmHg, PSI, kPa Temperature and Pressure Sensor No Yes, in flow steam Yes, in flow steam
Three Flow Cells Available; Low, Standard & High
Gilian® Gilibrator-2
The Gilian® Gilibrator-2 primary standard accuracy and performance validation for sampling pump airflows from 1 cc/min - 30 LPM.
Features
• Flow rate:
Low Flow Cell: 1 - 250 cc/min (total)
Standard Flow Cell: 20 - 6,000 cc/min (total)
High Flow Cell: 2 - 30 LPM (total)
• Consists of an electronic Gilibrator-2 base which is used with any of three sizes of flow cells
• Cells use a twist-on bayonet design for quick and easy mounting to the base
• These interchangeable cells generate perfect bubble films at the touch of a button
• Infrared sensors read the bubble flow rate, which is then calculated and displayed
• DC power source with internal battery pack
• Certified for accuracy and traceable to NIST
Low, Standard & High Flow Cell Kit Includes
• Control base
• Flow cell (low, standard or high)
• Tubing
• Soap solution with dispenser
• DC charger/AC power supply
• Hard shell carry case
Deluxe Cell Kit Includes
• Control base
• Three interchangeable cells for low, standard and high flow rates
• Tubing
• Soap solution with dispenser
• DC charger/AC power supply
• Hard shell carry case Part Number Description
GIL-800272 Gilian® Gilibrator-2 Low Flow Cell Kit With US Cord
GIL-800271 Gilian® Gilibrator-2 Standard Flow Cell Kit With US Cord
GIL-800270 Gilian® Gilibrator-2 High Flow Cell Kit With US Cord 2 - 30 LPM
GIL-801804 Gilian® Gilibrator-2 Deluxe Cell Kit With All Three Cell Sizes & US Cord
GIL-800450 Soap Solution Flow Cell For Gilian® Gilibrator-2 Calibrator, 8 oz -
Zefon® DigiCal™ Flow Calibrator
The Zefon® DigiCal™ Flow Calibrator provides instantaneous calibration for instruments like the Zefon® Escort® LC pump or the secondary flow standard inside the Escort ELF® sampling pumps. Just press the plunger and the DigiCal™ calibrator does the work. Its unique flow cell replaces conventional bubble tubes and makes calibration easier. The DigiCal™ Calibrator achieves extreme accuracy by utilizing a computerized flow meter that provides instantaneous flow readouts on a digital display.
Features
• Flow rate:
Zefon® DigiCal™ 5: 1 - 6,000 cc/min (total)
Zefon® DigiCal™ 30: 0.1 - 30 LPM (total)
• ± 0.5% accuracy
• Microprocessor controlled to provide fast, accurate, repeatable measurements
• Work at any altitude without correction
• Instant readout of volumetric flow
Includes
• Zefon® DigiCal™ Flow Calibrator
• Soap solution
• Dispenser bottle
• Charger
• User manual
ZE-655273 Soap Bubble Solution For Zefon® DigiCalTM Flow Calibrator, 8 oz
ZE-ZA0122 Pelican 1400 Carrying Case With Pick-N-Pluck Foam
Zefon® Bio-Pump® Plus
The Zefon® Bio-Pump® Plus is the smallest, lightest and easiest to use portable, battery-powered IAQ pumps designed for exclusive use with Air-O-Cell® and Via-Cell® cassettes at a flow rate of 15 LPM.
Features
• Real time display showing actual run time
• Programmable sample time (allows unattended operation)
• "Sample Complete" audible & visual indicators
• "Quick Sample" operation
• Long Lasting NiMH battery provides approx. 8 hours of continuous run time or approx. 100 5-minute samples
Model Zefon® Bio-Pump® Plus Kit
Includes • Zefon® Bio-Pump® Plus pump
• Air flow indicator
• (10) Air-O-Cell® cassettes
• Charger
• Warranty card
• User manual
• Carrying case
Zefon® Bio-Pump® Plus Pro Kit
• Zefon® Bio-Pump® Plus pump
• Air flow indicator
• (10) Air-O-Cell® cassettes
• (25) Bio-Tape™ slides
• Bioisolation filter
• Tripod stand
• Charger
• Warranty card
• User manual
• Carrying case
ZE-ZBP-205 Zefon® Bio-Pump® Plus With 110-230V Charger With North American Plug
ZE-ZBP-PROKIT-PLUS Zefon® Bio-Pump® Plus Pro Kit With Accessories
ZE-ZBP-205-CKIT Zefon® Bio-Pump® Plus With TSI 4046 Calibrator Kit
ZE-ZA0047 Bioisolation Filter For Zefon® Bio-Pump® Plus
ZE-ZA0043 Zefon® Heavy Duty Tripod Stand For Zefon Bio-Pump® Plus
* 230V also available
Zefon® Z-Lite™ IAQ Mold Sampling Starter Kits
The Zefon® Z-Lite™ kits are an easy, convenient way to get everything you need to begin sampling for mold. It is a low maintenance-oscillating pump designed for use with all mold sampling cassettes and impactors.
Model Basic Kit
Zefon
• Zefon
• Air flow indicator
• (10) Air-O-Cell® cassettes
• TSI 4046 calibrator kit
• Charger
• Warranty card
• User manual
• Carrying case
Features
• Flow rate: 3 - 33 LPM
• Built-in adjustable flow meter/regulator
• Rubber suction cup feet to prevent movement while in use
Includes • Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve
• Tubing
• (10) Air-O-Cell® cassettes
• Bioisolation filter
• Tripod stand
• Basic set-up and user instructions
• Toolbox style carrying case
Deluxe Kit
• Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve
• Tubing
• (20) Air-O-Cell® cassettes
• (25) Bio-Tape™ slides
• (10) Mold swabs
• Bioisolation filter
• Tripod stand
• Basic set-up and user instructions
• Toolbox style carrying case
Ultimate Kit
• Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve
• Tubing
• (50) Air-O-Cell® cassettes
• (50) Bio-Tape™ slides
• (50) Mold swabs
• (10) Inner wall attachments
• Bioisolation filter
• Tripod stand
• Basic set-up and user instructions
• Toolbox style carrying case
Buck Bio-Series Pumps
The Buck Bio-Series pumps are simple to operate and provides a selectable, continuous, and constant sample flowrate. Its quiet operation allows unobtrusive sampling in IAQ, medical, clean room, public, and residential building applications. The front key pad is organized into three functional key groups: Power (ONOFF), Timing (1, 2, 5, 10 minute samples) and Calibration (cal mode, increase flow, decrease flow). End of sample notice is provided by the lit LED "Complete" and three short beep.
Buck BioAire™ Bioaerosol Sampling Pump
Features
• Flow rate: 5 - 20 LPM
• Small, lightweight, and compact
• Accepts both Allergenco-D or Air-O-Cell® cassettes
• NiCad batteries with 6 - 8 hours continuous run time at 15 LPM
• Convenient timer for 1, 2, 5, 10 minute samples and continuous mode
• End-of-cycle audible & visual
• Easy keypad calibration without tools
Includes
• Buck BioAire™ pump
• Calibration rotameter assembly (APB-706100)
• Standard smart 120V charger
• User manual
Buck BioAire™ Pump Model B520
APB-108000 Durable Hard Plastic Carrying Case With Foam Insert
Buck BioSlide™ Biocontaminent Sampling Pump
APB-707000 Buck BioSlide™ Pump Model B1020
APB-108000 Durable Hard Plastic Carrying Case With Foam Insert
Features
• Flow rate: 10 - 20 LPM
• Small, lightweight, and compact
• Accepts generic greased slides
• NiCad batteries with 5 - 6 hours continuous run time at 15 LPM
• End-of-cycle and battery level audible & visual
• Tripod mount for area sampling
Includes
• Buck BioSlide™ pump
• Calibration rotameter assembly (APB-706100)
• Standard smart 120V charger
• User manual
Buck Bio-Culture™ Biocontaminent Sampling Pump
Features
• Flow rate: 30 - 120 LPM
• Holds 90 mm agar petri dish
• 380 holes - 1 mm diameter
• Timing routine of 1, 2, 5 & 10 minutes
• Tripod mount to allow 90o sampling
• Sampling head is easily sterilized with gas torch or autoclave
• Four times the flow rate of an Anderson sampler
Includes
• Buck Bio-Culture™ pump
• Pencil torch
• Tripod
• Standard smart 120V charger
• User manual
• Carrying case
APB-708500 Calibration Head For Buck Bio-Culture™ Pump
MicroflowTM α Microbiological Air Sampler
This instrument has been developed for airborne biological contaminants sampling in order to access the level of biocontamination in critical places (ex: clean rooms, operating rooms, pharmaceutical production plants, food and cosmetic industries, water purification plants, landfills, etc.) and in normal working life situations and not (air conditioning and ventilation controls).
MicroflowTM α allows a wide range of airborne bio-contaminant sampling by impacting on agar plates (60 mm + 2 mm contact plate or 90 mm + 2 mm petri dish).
Features
• Flow rate: 30 - 60 - 90 - 100 - 120 LPM
• Used with:
60 + 2 mm contact plate (MicroflowTM α 60)
90 + 2 mm petri dish (MicroflowTM α 90/C)
Both with contact plate and petri dish (MicroflowTM α 60-90/C)
• NiMH rechargeable battery, without memory effect
• Silent microprocessor controlled fan to ensure maximum reliability on the sampled air volume
• Compensation airflow system (in compensated models)
• Low battery control and alarm
• Prompts in 5 languages: English, French, German, Spanish, Italian & functions are "step-by-step" visualized
• Delay start
•Total volume of sampled air programmable from 1 up to 2000 L, with 1 L steps
•Manual sampling for air volumes greater than 2000 L
Includes
MicroflowTM α sampler
• IR remote control
• Pencil torch
• Additional 60 mm aluminum sampling head
• Base for sampler vertical positioning
• Battery charger
• Calibration report
• Warranty card
• User manual
• Carrying case
• Sequential sampling also as required by ISPESL guidelines
• Storing and displayed up to 99 samplings, with record of progressive n number, date, hour, sampling volume or time, flow rate, type of sampling (manual, sequential, programmable)
• USB port to download data to a PC (optional)
• Calibration control function (with optional calibration kit)
• Remote switch with infrared rays control
• Vertical or horizontal sampling (90° and 180°)
• Prepared for mounting on photographic tripod
• MicroflowTM α sampler
• IR remote control
• Pencil torch
• Additional 90 mm aluminum sampling head
• Base for sampler vertical positioning
• Battery charger
• Calibration report
• Warranty card
• User manual
• Carrying case
AQ-G.1004 MicroFlow™ α Kit 60 (For Use With Contact Plates 60 mm ± 2 mm)
AQ-G.1015 MicroFlow™ α Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compen
sation
AQ-G.1015-SS MicroFlow™ α Stainless Steel Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation
AQ-G.1027 MicroFlow™ α Kit 60-90/C (For Use With 60 mm ± 2 mm Contact Plate & With 90 mm ± 2 mm Petri Dishes), With Flow Compensation
AQ-G.1120 Digital Calibration Kit For MicroFlow™ α Includes: Digital Differential Pressure Meter, Fitting Tubes & Conversion Table
AQ-G.1117-A USB Interface For Data Download To PC
Includes: Data Transmission & Data Management Software (In Compliance With UNICHIM No.1962)
(Note: Data download requires a structural modification. In case of later purchase, MicroFlow™ α must be returned to Aquaria S.R.L. for software installation.)
• MicroflowTM α sampler
• IR remote control
• Pencil torch
• 60 & 90 mm aluminum head assembly
• Base for sampler vertical positioning
• Battery charger
• Calibration report
• Warranty card
• User manual
• Carrying case
AQ-A.2004
Zefon® A6 Impactor
The Zefon® A6 Impactor sampler is an exact replica of the popular Andersen N-6 single stage impactor. The Zefon® A6 impactor is an aluminum device consisting of a top inlet "cone", a sampling head impactor stage which contains 400 precision drilled holes and a base section, which holds the agar media. The sampler is held together by three spring clamps and sealed with two o-ring gaskets. When air is drawn through the sampler, multiple jets of air direct any airborne particles toward the surface of the agar collection media surface where the particles are impacted and collected. The agar collection media is then sent to a laboratory for analysis.
ZE-Z-A6-CAL Adapter For "In-Line" Impactor Calibration -
ZE-ZA0043 Zefon® Heavy Duty Tripod Stand For Zefon® A6 Impactor -
InfZ
ne When Using A Zefon® A6 Impactor
Accurate results when using a Zefon® A6 Impactor depend on proper measurement of flow through the impactor inlet. This can be best measured using a bubble or dry piston flow calibrator traceable to NIST standard (such as a Bios Defender or Gilian® Gilibrator) set up with the Zefon® A6 impactor "in-line". To your impactor "in-line", be sure to order the Z-A6-CAL adapter, which fits over the impactor inlet and allows tubing to be connected to it.
Includes
• Zefon® A6 Impactor
• Pump flow meter
• 1/4" I.D. tubing
• Tripod stand
• Carrying case
A Static Conductive Replica Of The 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone
Zefon® 10 mm Static Conductive Nylon Cyclone
The Zefon® 10 mm Conductive Nylon Cyclone (Sensidyne "Dorr-Oliver" style) is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM.
Features
• Flow rate:
ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm
Other applications: 2 LPM with a nominal particle diameter of 3.5 μm
• Conductive, eliminates any possible bias in sampling results from static charging
• Lightweight design only 3.6 oz for the complete assembly including cassette and holder
• Certifications: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust
ZE-ZA0080
ZE-ZA0081
ZE-ZA0063
ZE-ZA0085
ZE-ZA0061
10 mm Nylon Cyclone Efficiency Curve Comparison at 1.7 lpm
Particle Size (µ)
Source: Internal Zefon performance tests with all 4 cyclones under identical conditions
Zefon 10 mm
Heavy Duty
Sensidyne
TSI
Zefon 10 mm
Conductive
Zefon® 10 mm Conductive Nylon Cyclone
Zefon® 10 mm Conductive Nylon Cyclone With Cassette/Cyclone Holder
Zefon® 1 Liter Cyclone Calibration Jar For Aluminum Cyclone & Zefon® Conductive Nylon Cyclone
Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones)
Zefon® Universal Cassette/Cyclone Holder Only
ZE-ZA0082 Replacement Grit Pots, 25/Pack
The cyclone must be used in conjuction with a cassette/cyclone holder. Compatible with both the Zefon® cassette/cyclone holder ZE-ZA0061 or the SKC
10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Sampler For Respirable Dust & Silica
The "Dorr-Oliver" 10 mm Nylon Cyclone is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM.
Features
• Flow rate:
ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm Other applications: 2 LPM with a nominal particle diameter of 3.5 μm
• Certification: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust
Part Number Description
GIL-800061 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone
GIL-7013376 Cyclone Calibration Jar For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone & Inhalable Dust Sampler Head
GIL-200159 Replacement Cyclone Grit Pot For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone
GIL-801124 Replacement Cylcone Vortex Finder Accessory For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone
Inf Z ne
Cyclone Calibration Jar
When ordering a traditional Sensisyne "Dorr-Oliver" cyclone sampler, be sure to also order a Cyclone Calibration Jar GIL-7013376. Since a Sensidyne "Dorr-Oliver" cyclone has only a single hose connection, this jar allows proper placement of the cyclone filter between the sampling pump and the calibrator device.
A replica of the SKC Aluminum Cyclone
Zefon® Aluminum Cyclone For Respirable Dust
The Zefon® Respirable Dust Aluminum Cyclone is used in conjunction with 25 mm or 37 mm 3-piece filter cassettes to separate and remove larger particles from the respirable particles collected on the cassette’s filter. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm at 2.5 LPM flowrate. A cyclone holder and 25 mm or 37 mm 3-piece filter cassette are required for use of the Zefon® Aluminum Cyclone.
Features
• Aluminum construction is static conductive, eliminating interference
• Lightweight design only 1.1 oz
• Fully interchangeable with SKC Aluminum Cyclone
• Certification: specified in NIOSH method 0600 for respirable particulates & NIOSH 7500 for silica, crystalline
Part Number Description
ZE-ZA0060 Zefon® 37 mm Aluminum Cyclone For Respirable Dust
ZE-ZA0075 Zefon® 25 mm Aluminum Cyclone For Respirable Dust
ZE-ZA0062 Zefon® 37 mm Aluminum Cyclone For Respirable Dust With Holder
ZE-ZA0076 Zefon® 25 mm Aluminum Cyclone For Respirable Dust With Holder
ZE-ZA0063 Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone
ZE-ZA0085 Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones
ZE-ZA0061 Zefon® Universal Cassette/Cyclone Holder Only
ZE-ZA0066 Replacement Grit Pots For Aluminum Cyclone, 25/Pack
ZE-ZA0067 Replacement O-Rings For Aluminum Cyclone, 5/Pack
Shown with cassette installed in holder
Zefon® Aluminum Cyclone Calibration Adapter
A chamber specifically designed to fit over the Zefon® Aluminum Cyclone and connect 1/4" I.D. tubing for flow calibration. This provides the best calibration option by taking an actual measurement as close to the cyclone inlet as possible. Chamber fits both Zefon® brand and SKC brand 37 mm and 25 mm aluminum cyclones.
Part Number Description
ZE-ZA0011
Zefon® Aluminum Cyclone Calibration Adapter
Zefon® Calibration Jar
The Zefon® Cyclone Calibration Jar is a container with all the proper fittings and connections to calibrate personal sampling pumps with the Zefon®, SKC, or Sensidyne "Dorr-Oliver" Cyclones and inhalable dust samplers.
Part Number Description
ZE-ZA0063
ZE-ZA0085
Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone
Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne “Dorr-Oliver” Nylon Cyclones
Zefon® Bio-Tape™ - Standardized Method For Surface Sampling
Zefon® Bio-Tape™ provides a standardized surface sampling method used for the determination of possible microbial, bioaerosol, and inorganic dust contamination. It provides the ability to quickly take a sample and measure the relative degree of contamination. It is especially useful when sampling valuable or non-transportable materials and is very effective on smooth areas of concern.
Features
• Provides sample consistency
• Individually serialized for traceability
• Prevents cross contamination
• Eliminates problems of placing tape in a zip bag, or broken glass slides
• Samples may be archived by the laboratory for later review
• Requires less laboratory prep time
Part Number Description
ZE-BT0025
ZE-BT0050
ZE-BT0500
* Limited shelf life
Zefon® Sterile Surface Mold Swabs
Zefon®Bio-Tape™ Slides, 25/Box
Zefon®Bio-Tape™ Slides, 50/Box
Zefon®Bio-Tape™ Slides, 500/Box
Zefon® Sterile Surface Swabs are an easy way to sample suspect areas for mold contamination. Simply swab the suspect area and submit to a laboratory where the sample will be cultured and the type of mold identified. Each swab comes in an easy to use container for sampling, transport and storage.
Part Number Description
ZE-ZA0020
ZE-ZA0023
* Limited shelf life
Zefon® Mold Swab Kit
Zefon® Sterile Mold Surface Swabs
Includes
• (10) Sterile Surface Mold Swabs
• (10) Sterile 10 cm x 5 cm templates
Zefon® Preloaded Air Sampling Filter Cassettes
Zefon® offers a complete line of air sampling cassettes manufactured to meet all applicable NIOSH, OSHA, and EPA standards. All cassette housings are manufactured in-house from polystyrene or polypropylene and are available in two or three piece configurations. Cassettes are individually assembled and preloaded under stringent quality assurance standards with only the finest quality membrane and support pads.
Features
• Fully assembled, preloaded and ready to use
• Leak free construction eliminates sample loss
• Configurations available to conform with most NIOSH standards that require filter cassettes
• Wide selection of filter membrane types
• Available with Zefon® Solu-Sert™ or Gravi-Sert™ filter capsules installed
• Sterile models available for fluid contamination sampling and microbiological analysis
• Ultra Pure PTFE models available for pharmaceutical compound sampling
ZE-7M93M-SB 37 mm 0.8 μm 3-Piece, Styrene, Banded Match-Weighed Filters With Security Band 50/Box
*Limited shelf life
Gravimetric Pre-Weighed Cassettes
Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® pre-weighed cassettes eliminate the inconvenience of pre-weighing filters by providing the filter weight on each cassette prior to sampling.
Features
• Each cassette is labeled with weight and serial number
• Use of pure homopolymer PVC filters provides excellent weight stability
• PVC filters specially designed with no silica and low ash properties
Inf Z ne
Using A Match-Weight Cassette
Using A Pre-Weighed Cassette
Environmental conditions can have a significant effect on filter weight readings. When using Zefon® pre-weighed cassettes, it is important that the post sample weighing is performed under the same environmental conditions used at the Zefon® factory. Those conditions are set at a temperature of 68°F and a relative humidity of 50%.
Using Zefon® pre-weighed cassettes does not comply with OSHA directives which require both the "tare weight" and "secondary weight" to be performed on the same microbalance and environmental conditions. If complying with this directive is a concern, match-weighed cassettes are a good alternative way to save time and still comply with the directive.
The weight tolerance of match weighed filters references the maximum difference in weight from the test (top) filter and the control (bottom) filter. A stated tolerance of 50 μg means that the control filter may differ in weight no more than 50 μg from the test filter. This is important to know during post sample weighing as the weight tolerance of the 2 filters needs to be considered when calculating results.
During manufacture, filters with matched weights (within the given tolerance) are inserted into the cassette in random order. Thus, it is possible for the control filter to weigh more than the test filter before sampling (within the given tolerance). If the control filter still weighs more after sampling, a sample likely was not collected. Please check your equipment for proper operation and pump flow.
Gravimetric Match-Weighed Cassettes
Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® matchweighed cassettes eliminate the need of weighing filters before sampling by providing two filters which are matched in weight. The top filter collects particulate and the bottom filter serves as a control. After sampling, both filters are weighed and the difference in weight equals the amount of contaminate collected.
Matched-Weighed Configuration
Features
• Each cassette labeled with serial number
• Color coded to indicate filter type
• Preloaded - ready to use
Zefon® 25 mm PCM Preloaded Filter Asbestos Sampling Cassettes
Zefon® and EMS offer PCM 25 mm conductive air sampling cassettes designed and manufactured to meet all applicable NIOSH, AHERA, OSHA, and EPA standards. The cassette housings are manufactured in-house from high quality polypropylene and are individually assembled and preloaded under stringent quality control standards.
Features
• 2" conductive extension cowl
• 3-piece housing
• Meets regulatory requirements
• Each cassette comes with a unique serial number
*Limited shelf life
Zefon® Air-O-Cell® Bioaerosol Cassettes
The Zefon® Air-O-Cell® is a unique sampling cassette designed for the rapid collection of a wide range of both viable and non-viable aero-allergens including mold spores, pollen, insect parts, skin cells, fibers and inorganic particulate.
These cassettes can be used with any standard off-the-shelf sampling pump capable of drawing 15 LPM open flow, including the Zefon® Bio-Pump® Plus, a convenient battery powered hand-held pump for ease of sampling.
ZE-AOC050
ZE-AOCCAL
Features
• Industry proven & accepted
• Independently validated
• Laboratory preferred, easy to analyze
• Proven results
• No sample loss during shipping & handling
• Pre-loaded, no slides to prepare
Air Sampling Cassettes
In-Line Calibration Adapter
ZE-AOC-WS10 Air-O-Cell® Inner Wall Samplers
ZE-AOCWS10-KIT Air-O-Cell® Inner Wall Sampler Kit
*Limited shelf life
Inner Wall Sampling Attachments
Zefon® Inner Wall Attachments are used in conjunction with Air-O-Cell®, MoldSNAP™, or Via-Cell® cassettes to non-destructively access microbial contamination in a wall cavity, equipment for proper operation and pump flow.
To use, simply drill a 3/8" hole (preferably by hand), connect the tubing attachment to the cassette and insert the tube into the wall.
& A Plunger Rod
Allergenco-D IAQ Air Sampling Cassettes
The Allergenco-D disposable IAQ air sampling cassette was developed for the sampling and collection of aeroallergens and bioaerosols for quantitative analysis of mold spores, pollen, skin fragments, insects, combustion particles, toners, environmental dusts, construction dusts, and other airborne particulates.
These cassettes employ a patented laminar flow venturi which provides higher readable collection efficiency than other IAQ cassettes as well as a more well defined impaction trace, helping to reduce analysis time.
Features
• Assembled under HEPA hoods
• Laminar flow venturi allows for the most uniform slit deposit in the industry
• Patented design
• Higher collection efficiency than other IAQ slit impactor cassettes
The Most Uniform Slit Sample Trace In The Industry!
Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes
The Allergenco-D Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK).
• Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace
• Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing
• Generous area on the cassette label for field notes such as sample location, dates and time
• Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive
• Designed to stack cassettes for easy storage and use
Micro5 MicroCell IAQ Air Sampling Cassettes
Utilizing a 360o impaction chamber, the Micro5 was pioneered to evenly & quantitatively collect aeroallergens such as pollens, mold & fungal spores, fibers, danders, insect components and other air-borne contaminants.
Features
• Exceptionally uniform collection trace
• Virtually 100% accurate for the entire fungal spore range
• Designed to operate at a flow rate of 5 LPM to ensure optimal collection efficiency
Part Number Description Quantity
EMS-120170 Micro5 Air Sampling Cassettes 50/Box
EMS-120138-M5 Micro5 Inner Wall Samplers 10/Pack
*Limited shelf life
The Most Uniform Slit Sample Trace In The Industry!
Micro5 Posi-Track Full Slide Indoor Air Quality Impactor Cassettes
The Micro5 Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK).
• Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace
• Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing
• Generous area on the cassette label for field notes such as sample location, dates and time
• Minimizes handling and mounting of sample traces for microscopic particle counting
• Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive
• Barcoded serial number (POSI-TRACK) allow for automated input of sample numbers into laboratory software (LIMS) and chain-of custody forms
• Deposition of particles/spores onto the adhesive is very uniform due to the design of the laminar flow venturi within the spore trap
• Designed to stack cassettes for easy storage and use
Zefon® Via-Cell® Bioaerosol Sampling Cassettes
The Zefon® Via-Cell® bioaerosol sampling cassette is designed to collect both viable and non-viable bioaerosols, maintain viability of the viable mold spores and prevent growth during transport to the laboratory. Simply connect it to any pump calibrated to 15 LPM and run your sample. The key to the Via-Cell® is that the media used for collection maintains viability of spores and allows several analysis options.
One Sample, Multiple Analysis Options
Culturable Sampling
The Zefon® Via-Cell® sampler is the perfect tool for collecting viable organisms and culturing them on agar plates. Simply dilute the media in sterile water and transfer to a culture plate.
PCR Analysis
The Zefon® Via-Cell® utilizes a water soluble collection media which is ideal for PCR and other chemical types of analysis. Once the sample is diluted in water, it can be transferred most anywhere.
Direct Microscopy
Samples collected using the Zefon® Via-Cell® sampler may be "pre-screened" using direct microscopy methods, which allows the analyst to decide if additional analysis techniques are needed, which may include culturing or standard direct microscopy analysis.
Part Number Description Quantity
ZE-VIA010 Via-Cell® Air Sampling Cassettes 10/Box
*Limited shelf life
Zefon® Gemini® Twin Port Sorbent Tube Sampler
The Zefon® Gemini® Twin-Port Sorbent Tube Sampler can be used with the Zefon® Escort ELF®, or just about any other sampling pump able to pull a flow rate of 1.5 LPM at 25" of water backpressure. It offers increased flexibility and control in gathering samples through sorbent tubes.
If air is being sampled for two or more contaminants, the Gemini can draw samples at independent flow rates through tubes containing different sorbents. In situations where a single contaminant is being sampled, sampling on two tubes of the same type can be done simultaneously at different flow rates. This type of sampling protects against breakthrough which occurs when a tube’s sampling capacity is exceeded because the concentration of a contaminant is higher than anticipated. Duplicate sampling at the same flow rate can also be done to achieve better results.
Features
• Valved mechanism allows flow control down to 0.001 LPM
• Control the flow rate of each port independently
• Includes tube covers to fit both large and small tube sizes
Part Number Description
ZE-497697
Zefon® Gemini® Twin Port Sampling Kit
Zefon® Sorbent Tubes
Includes
• Zefon® Gemini Twin-Port Sorbent Tube sampler
• Tube protectors
• Y-connectors
• Clips
• Carrying case
Zefon® Sorbent Tubes are high quality glass tubes that are packed with accurately weighed, high-purity sorbents. They are designed to adsorb vapors and gases passed over them when used with low flow sampling pumps and fit a variety of tube holders, including the Zefon® Gemini® Twin Port Sorbent Tube Sampler.
Many Zefon® sorbent tubes are divided into sections, with two absorbent sections being most common. The first section is twice the size of the back section and collects the compounds of interest. The second section is a backup section to determine if airborne contaminants breakthrough occurred on the front section.
Features
• Highest sorbent material purity for contamination-free samples
• Accurate sorbent weight for uniform testing results
• Uniform pressure drop to assure repeatable sampling results
• Designed to comply with all NIOSH specifications for tube dimensions, sorbent quality, particle size, divider composition and pore size
* Microlite sorbent is equivalent to Hydrar, Carulite, and the SKC Anasorb C300.
Personal Pump Accessories
Sample Tubing
Part Number Description
CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft
ZE-456226 3/8'' O.D. x 1/4'' I.D. x 36" Long PVC Tubing With Tube Clip
Cassette Accessories
Part Number Description
ZE-ZA0046 Cassette Opener For 25 mm, 37 mm & Air-O-Cell® Cassettes
ZE-ZA0049 Cassette Opener For 47 mm & Air-O-Cell® Cassettes
ZE-459743 Metal Luer Adapters, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)
ZE-ZA0010 25 mm Conductive Filter Transport Case
Buck Low Flow Sorbent Tube Holders
Available both with and without flow adjustment. Use non-adjustable when using a sampling pump designed specifically for low flow sampling without adapters. Use adjustable flow to use with standard sampling pumps in constant pressure mode. Tube holder comes setup for 6 mm x 70 mm tubes. Additional size tube covers maybe purchased separately.
Sorbent Tube Accessories
Part Number Description
GIL-7015377P Tube Tip Breaker, 5/Pack
APB-109032 Single Tube Holder With Non-Adjustable Flow
APB-109030 Single Tube Holder With Adjustable Flow (5 - 800 cc/min)
APB-109033 Single Tube Holder With Adjustable Flow (5 - 100 cc/min)
APB-109022 6 mm O.D. x 70 mm L Tube Cover
APB-109024 8 mm O.D. x 110 mm L Tube Cover
APB-109026 10 mm O.D. x 150 mm L Tube Cover
APB-109028 10 mm O.D. x 220 mm L Tube Cover
ZE-456226
CY-8860-4335
ZE-ZA0046
ZE-ZA0061
APB-109030
GIL-7015377P Tube Covers
ZE-459743
ZE-ZA0010
ZE-ZA0005
Area Pump Replacement Parts
For Zefon® High Volume Diaphragm Area Sampling Pump
Part Number Description
ZE-03113 1/8" Air Flow Regulator Valve
ZE-03180 1/8" To 1/4" Conversion Fitting
ZE-03200 1/4" Hose Barb
ZE-03184 Rubber Foot For Diaphragm Pumps
ZE-03179 Muffler For Diaphragm Pump
For Zefon® High Volume Rotary Vane Sampling Pump
Part Number Description
ZE-03113 1/8" Air Flow Regulator Valve
ZE-03200 1/4" Hose Barb
ZE-03201 Rubber Foot For ZE-ZHV00 Pump
ZE-AL-9800-52 Exhaust Filter For ZE-ZHV00 Pump
ZE-ZGHV01 Glass Muffler Jar For ZE-ZHV00 Pump
ZE-AA928 Felt Filters For ZE-ZHV00 Pump
Area Pump Accessories
Part Number Description
EMS-200550 Premium Telescopic Sampling Tripod Stand
CY-8860-4335 3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft
ZE-459743 Metal Luer Adapter, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)
ZE-03113
ZE-03113
ZE-ZGHV01
ZE-03180
ZE-AA928
ZE-03200
ZE-03200
ZE-03184
ZE-03201
ZE-03179
ZE-459743
ZE-ZA0005
EMS-200550
CY-8860-4335
Air Sampling Bag Selection Guide
Choosing The Best Film For Your Gas Sampling Bag Needs
Tedlar®
ALTEF
Properties
• Low gas permeation
• High tensile strength
• Max. operating temp: 400°F
• Unaffected by the chemical components of gases commonly sampled
• Developed specifically for gas sampling applications
• Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols
• Max. operating temp: 260°F
• Made of 0.003" thick film
Multi-layer Foil
• Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2
• Foil layers provide very low permeability and complete moisture barrier
• Max. operating temp: 190°F
• Opaqueness protects samples from ultraviolet light
FEP
• One of the most chemically inert materials available for making gas sampling bags
• Max operating temperature: 400°F
• Virtually transparent
PFA
TFM
• Highest purity, most chemically inert film available for making gas sampling bags
• Wide temp range -420°F to 500°F
• High purity, flexible, low permeation versus FEP and PFA
• Translucent
• Wide temperature range; from –328°F to 500°F
Advantages
• Less permeable than FEP, PFA and TFM
• Bags resist puncture in the field
• Less expensive than FEP, PFA, TFM film
• Suitable for sampling most VOC's and many sulfur compounds
• Low VOC background
• Longer sample storage times than most other bag materials
• Does not exhibit background levels of DMAC or phenol
• Lower permeability than Tedlar® to CO2, N2, and CH4
• Superior resistance to solvents
• The only bag material that adequately holds H2S for long periods
• Ideal for collecting low molecular weight compounds
• Sample stability up to 5 days for most compounds
• Very low permeability to O2 and CO2
• Good VOC stability
• Less expensive than Tedlar® and ALTEF
• Works well in extreme temperatures from -400°F to 400°F
• Heavier gauge film is resistant to most severe corrosives as well as tolerates applications involving rough handling or difficult service conditions
• Less expensive than PFA
• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids
• Temps from –400°F to 500°F
• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids
• Sample stability for 4 to 5 days for most compounds
• Withstands temperatures from –400°F to 500°F
Limitations
• Exhibits background levels of DMAC and phenol
• High permeation rate for CO2
• Relatively high permeation rate for O2
• More permeable to most compounds than Tedlar®
• Not suitable for sampling ketones and esters in high concentrations (>30%)
• Less resistance to UV light than Tedlar®
• Many sulfur compounds must be analyzed within 24 hours.
• More expensive than Tedlar®
• Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials
• Recommend analyzing within 48 hours after collection for CH4, H2S, CO, and CO2
• Poor long term storage stability for most VOC's and sulfur compounds
• Much more permeable and more expensive than Tedlar®, ALTEF, and MultiLayer Foil bags
• Lower tensile strength than Tedlar®
• Poor long term storage stability for most VOC's and sulfur compounds
• The most expensive film option for gas sampling bags
• Much more permeable than Tedlar®
• Expensive
• Tears easily
• Low tensile strength
• More permeable than Tedlar®, ALTEF, and Multi-Layer foil bags
Valves And Fittings For Gas Sampling Bags
Polypropylene Locking Combo Vakve with Septum
Type Stainless Steel Fitting for Tubing or Septum
Valves and Fittings
Polypropylene Screw Cap Combo Valve With Replaceable Septum
Polypropylene Locking® Combo Valve With Septum
Features
• On/Off valve function with replaceable septum in a single unit
• Made of Inert polypropylene
• Quick turning screw cap to open and close valve
• Visual confirmation that valve is open or closed
• On/Off valve function with septum in a single unit
• Made of Inert polypropylene
• Push/Pull (On/Off) valve stem
• Quick Locking function, in closed position Fluoropolymer faced septum, with Ultra-low bleed silicone
Stainless Steel TCLP Fitting With Replaceable Septum
Swagelok® Type Stainless Steel Fitting For Tubing Or Septum
Nickel Plated Halkey® Roberts Barbed On/Off Valve
Plastic Jaco® Fitting For Tubing Or Septum
PFA Fitting For Tubing Or Septum
• Stainless steel body construction with aluminum cap
• Designed for use with Zero Headspace Extractors
• Replaceable fluoropolymer faced septum
• Stainless steel construction
• Option of cap for tubing or septum
• Replaceable fluoropolymer faced septum with large area
• Barbed stem for attaching tubing
• Leak resistant seal in closed position
• Compression ferrule secures tubing onto fitting
• Polypropylene molded construction
• Option of cap for tubing, or cap with septum
• Replaceable fluoropolymer faced septum with large area
• PFA fluoropolymer construction
• Option of cap for tubing, or cap with septum
• Compression ferrule secures tubing onto fitting
• Replaceable fluoropolymer faced septum with large area
Tedlar® Gas Sampling Bag With Screw Cap Combo Valve With Replaceable Septum
JIP-GSTP00-0606NSG1B 0.6 L 6" x 6" 3/16" O.D. 10/Pack
JIP-GSTP010707NSG1B 1 L 7" x 7" 3/16" O.D. 10/Pack JIP-GSTP00-0610NSG1B 1.2 L 6" x 6" 3/16" O.D. 10/Pack JIP-GSTP02-0909NSG1B 2 L 9" x 9" 3/16" O.D. 10/Pack
JIP-GSTP03-1010NSG1B 3 L 10" x 10" 3/16" O.D. 10/Pack
JIP-GSTP05-1212NSG1B 5 L 12" x 12" 3/16" O.D. 10/Pack
JIP-GSTP07-1215NSG1B 7 L 12" x 15" 3/16" O.D. 10/Pack
JIP-GSTP08-1217NSG1B 8 L 12" x 17" 3/16" O.D. 10/Pack
JIP-GSTP09-1218NSG1B 9.5 L 12" x 18" 3/16" O.D. 10/Pack
JIP-GSTP10-1219NSG1B 10 L 12" x 19" 3/16" O.D. 10/Pack
JIP-GSTP12-1221NSG1B 12 L 12" x 21" 3/16"
JIP-GSTP16-1818NSG1B
JIP-GSTP25-1824NSG1B 25 L 18" x 24"
JIP-GSTP40-2424NSG1B
JIP-GSTP56-2430NSG1B
JIP-GSTP73-2436NSG1B
JIP-GSTP80-3030NSG1B
JIP-GSTP1003036NSG1B
JIP-SEP5007-NSCV-10
Polypropylene Screw Cap Combo Valve with Replaceable Septum
Stainless Steel Push/Pull Valve
Stainless Steel TCLP Fitting with Replaceable Septum
PFA Fitting Tubing or Septum PTFE On/Off Valve with Stopcock
Nickel Plated HR Barbed On/Off Valve
Plastic Jaco Plating for Tubing or Septum
Swagelok
Direct Read Passive Monitoring System
ChromAir® System Chemical Detection Badges
In some settings, monitoring the amount of exposure is the key to safe working conditions. ChromAir® is designed to detect exposure dose levels to specific toxic chemicals. The ChromAir® chemical exposure monitoring badge offers six exposure levels, with most indicating from one-tenth to two times the Permissible Exposure Limit (PEL) Time Weighted Average (TWA) for an eight-hour work period. To determine the average concentration, users can locate the highest cell with a color change and divide the corresponding dose level (parts per million times hour) by the sampling time in hours.
For higher resolution and accuracy, the ChromAir® badges can-be-used with the ChromAir® color comparators. The color scales on the color comparator identically match the colors formed on the ChromAir® badge.
ChromAir® Badges
MT-380004-10
*1ChromAir® glutaraldehyde STEL badges are for 15 minutes of monitoring only. The scale on the badge is in ppm *2ChromAir® mercury badge and color comparator scale is in mg/m3 hr *3Coefficient must be applied to scale printed on badge
ChromAir® ozone badges are ten times more sensitive to ozone than nitrogen dioxide
Accessories
MT-401966-10
MT-401966-100
MT-401966-500
Features
• Easy to read color change
• Highly sensitive and selective
• Exposure data read directly from badge
• Measure TWA exposure
• Immediate response for short-term exposure measurements
• Patented design minimizes effects of humidity and velocity
• Light-weight and cost effective for personnel and area monitoring
Strap Clips, 10/Pack
Strap Clips, 100/Pack
Strap Clips, 500/Pack
How Colorimetric Detection Chemistry Works
Color originates from the complex and fascinating interaction of visible light with chromophores, or groups of atoms in molecules which are capable of absorbing certain wavelengths of visible light. Due to this absorption phenomenon, these substances are perceived as having color. The hue and depth of the perceived color are related to the specific wavelengths absorbed and the intrinsic absorption efficiency of the molecule, respectively. The distribution of electron density in a molecule is responsible for the absorption characteristics of that molecule. The alteration of electron density distribution in a molecule through reaction with another chemical species forms the basis for colorimetric chemical detection.
SafeAir® System Chemical Detection Badges
When there is a threat of chemical hazard, immediate detection is paramount. The SafeAir® System offers immediate visual confirmation of a specific chemical hazard. SafeAir® chemical detection badges are available for many different toxic industrial chemicals. The highly sensitive and selective sensor in the SafeAir® badge is designed to show a homogeneous and stable color change, which appears as an exclamation point when a particular chemical is present.
For higher resolution and wider range, the SafeAir® badges can-be-used with the SafeAir® color comparator. Slide the SafeAir® badge with the exclamation point facing up into the color comparator and turn the wheel until the colors match. Read the exposure dose in the exposure dose window.
Features
• Easy to use
• Highly sensitive and selective
• Ideal for daily employee screening or leak detection
• Measure TWA exposure
• Immediate, on-site results
• No calibration or laboratory analysis needed
SafeAir® System Badges
Color Comparators
MT-383022 Color Comparator For Phosgene Dura SafeAir® System Badges
Each MT-383020 Color Comparator For Phosgene Medi SafeAir® System Badges
Accessories
MT-401966-10 Strap Clips, 10/Pack
MT-401966-100 Strap Clips, 100/Pack
MT-401966-500 Strap Clips, 500/Pack
MT-401967-500 Adhesive Discs, 500/Pack
The Easiest To Use Colorimetric Gas Detector Tube Pump!
AP-20S Gas Detection Pump
The Sensidyne AP-20S gas detection pump kit when used in conjunction with Sensidyne detector tubes is a portable gas detection system that is lightweight, rugged, and capable of on-the-spot detection of numerous gases and vapors .
Features
• First detector tube pump with an antibacterial blue grip
• Sample flow indicator
• Detector tube tip cutter and storage
• Two-stage locking pump mechanism on the pump handle that allows sampling of either 50 ml or 100 ml sample volumes
• Pump has a positive start and stop for each stroke
• Withstands harsh environments and comes with a lifetime warrant
Includes
• AP-20S gas detection pump
• Two rubber tube-connectors
• Lubricant
• Tube handbook
• Manual
• Transport cage
Part Number Description
GIL-830-0001-01 AP-20S Gas Detection Pump Kit
GIL-830-1001-01 5 m Extension Hose For AP-20S Pump
GIL-830-1002-01 10 m Extension Hose For AP-20S Pump
GIL-830-1003-01 2 m Telescoping Extension Probe
*Sensidyne pump and Sensidyne colorimetric gas detector tubes are not interchangeable with other manufacturers’ pumps and detector tubes
Sensidyne Colorimetric Gas Detector Tubes
The Sensidyne colorimetric gas detector tubes safely allow users to perform field screening and tests for the presence of hazardous and toxic gases, and chemical vapors at a very low cost-per-sample. Gas detector tubes from Sensidyne are precision tubes offering a higher level of accuracy and repeatability for applications where results matter.
Applications
• Metal fabrication
• Degreasing
• Welding
• Sewage & waste water treatment plants
• Aerospace manufacturing
• Hazardous water handling
• Railroad & tank cars
• Parking garages
• Laboratory
• Pharmaceutical & medical manufacturing
• Food manufacturing
Tip Cutter
Sampling Flow Indication
Features
• Detector tubes for hundreds of gases
• Easy to use & provides a low-cost method of routine or spot sampling for gases & vapors
• Most tubes use a single pump stroke
• Plastic coating on the glass makes them shatterproof
• Uses smaller particles, which make the color change brighter and easier to see
• Perfect when sampling for a known target gas
• When the target gas or substance is unknown, the specialty HazMat kits provide an excellent answer for quick identification & measurement
Phosgene Water Vapor Compressed Breathing Air Tube
Phosphine & Arsine Water Vapor
Phosphine Xylene
N,N-Dimethyl Formamide Propane
N,N-Dimethylacetamide Propyl Acetate
N-Butane Propylene
N-Hexane
Propylene Oxide
Chlorine Dioxide Ethyl Acetate Isobutyl Alcohol Nickel Carbonyl Salinity In Water
*Sensidyne pump and Sensidyne colorimetric gas detector tubes are not interchangeable with other manufacturers’ pumps and detector tubes
ADVANTAGES
• Most of our tubes use a single pump stroke
• Pump has a positive start and stop for each stroke
• Uses smaller particles, which make the color change brighter and easier to see
• Plastic coating on the glass, makes them shatterproof
• Pump has an anti-bacterial grip, making it safer to use in medical settings
• Competitive pricing
• Extensive list of gases
Dräger
accuro® Gas Detection
Pump
The Dräger accuro® pump is a manually operated bellows pump that draws a calibrated 100 ml sample through the Short-Term Dräger-Tubes® for the sampling of toxic gases and vapors. It is independent of external energy sources therefore, there are no usage restrictions in areas of explosion hazard. An internal scissor mechanism built into the Dräger accuro® pump bellows provides parallel compression of the pump and an automatic stroke counter, which is integrated in the pump head, records the number of strokes.
Features
• For short-term measurements with a small numbers of strokes
• Hand-operated bellows pump with one-handed operation
• Built-in automatic stroke counter
• End-of-stroke indicator
• Number of Strokes: 1 - 50 strokes and higher
• Stroke volume: 100 ml (±5%)
Part Number Description Includes
DR-6400000 accuro® Pump
DR-8317186 Soft-Side accuro® Pump Kit
DR-4056443 Hard-Side accuro® Pump Kit
DR-6400561 1 m Extension Hose For Dräger accuro® & Dräger X-act® 5000 Pumps
*3 m & 10 m extension hose also available
• accuro® Pump
• Tube Opener
• Allen Wrench
• accuro® Pump
• Tube Opener
• Allen Wrench
• accuro® Pump
• Tube Opener
• Allen Wrench
• Spare Parts Kit
• NylonTransport Case
• Spare Parts Kit
• (10) Rubber Caps
• Pelican® Plastic Transport Case
• 1 m Extension Hose
• Adapter For Simultaneous Test Sets
*Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes
X-act® 5000 Automatic Tube Pump
The Dräger X-act® 5000 all-in-one, automatic tube pump is used in conjunction with Short-Term Dräger-Tubes®, simultest sets, and sorbent tubes for the sampling of toxic gases and vapors in the workplace. The bar code reader transfers all relevant measurement parameters using the bar code on the box of Dräger-Tubes.
DR-4523500 Dräger X-act® 5000 Pump
DR-4523617 Dräger X-act® 5000 Pump Kit
DR-6400561 1 m Extension Hose For Dräger accuro® & Dräger X-act® 5000 Pumps
*3 m, 10 m, 15 m & 30 m extension hose also available
Features
• For short-term measurements with higher numbers of strokes and sample taking with sampling tubes and systems
• Menu-driven automatic pump
• Built-in barcode reader with Class 3R
• Number of strokes: adjustable 1 - 199 strokes
• Stroke volume: 100 ml (±5%)
• (6) AA alkaline batteries or rechargeable NiMH battery pack
• Protection class: Ex-approved, IP 64
*Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes Part
• X-act® 5000 Pump
• Shoulder Strap
• X-act® 5000 Pump
• Shoulder Strap
• 1 m Extension Hose
• Rechargeable NiMH Battery
• 100-240 VAC Charger
• Adapter For Simultaneous Test Sets
Short-Term Dräger-Tubes®
Short-Term Dräger-Tubes® are an easy to use and cost effective way to measure toxic gases and vapors in the workplace. More than 200 different Short-Term Dräger-Tubes® are available to accurately make spot measurements for over 500 gases and vapors. The Short-Term Dräger-Tubes® are used in conjunction with either a manual or an automatic sampling pump using individual Short-Term Dräger-Tubes® or special 5 tube sets for simultaneous measurement.
Applications
• Determining and measuring concentration peaks
• Measuring personal exposure in the inhalation area
• Detecting leaks in pipelines, gas installations, etc.
• Air analysis in sewers, shafts and confined spaces
• Evaluation of concentration fluctuations in the workplace
• Measurement of contaminants in the worker’s breathing zone
• The investigation of confined spaces (ex: grain silos, chemical tanks, sewers) prior to entry
• Check for gas leaks in process pipelines
Acrylonitrile
Air Current (Smoke Tubes)
Features
• More than 200 Short-Term Dräger-Tubes® are available to measure spot concentrations of specific gases
• Designed for on-the-spot measurements at a particular location over a relatively short time period
Amine Test Qualitative
Ammonia
• Perfect when sampling for a known target gas
• Measurements in the range of the occupational exposure limits
• Measurements in the area of emission concentrations
• Measurements may last from 10 seconds to 15 minutes or so depending on the particular Short-Term Dräger-Tubes® and sampling pump
Answer the following questions to help narrow it down.
1. Do you require a portable or fixed gas detector?
2. Do you require a single gas or multi-gas detector?
3. What gas or gases do you need to measure?
Contact us and we will help you pick the right gas detector for your project Still stuck? 1-888-287-3732
4. Do you require an instrument without an internal pump (passive monitoring) or with an internal pump (active monitoring)?
5. Do you require an instrument with or without datalogging?
5 Versions Available CO, H2S, O2, CO/O2 & H2 Compensated CO
GasWatch 3 Single Gas Personal Monitor
The GasWatch 3 is the world’s smallest and lightest single gas and dual gas monitor designed to detect CO, H2S, O2, CO/O2 & H2 Compensated CO. Its compact form provides great comfort and flexibility in how you choose to wear it. It can be worn on your wrist as a watch, or clipped into your breathing zone on your lapel, hard hat or other safety equipment with the 360º rotation alligator clip.
Applications
• Refineries
• Petrochemical facilities
• Sewage treatment plants
• Fire departments
• Chemical plants
• Tunnels
• Mines
• Hazardous waste sites
Features
• Light and compact "watch type" design
• Easily worn clipped in your "breathing zone"
• Available with watch band or alligator clip
• Automatic backlight during alarm
• Sturdy IP-66/68 rated design
• Water, dust and radio frequency (RF) resistant
• Non-compliance indicator
Kit Includes
• GasWatch 3 monitor
• Watch band or alligator clip
• Spring pins (used to mount accessories on to the rear face)
• CR2450 coin-type lithium-ion battery
Gas Detected
Detection Principal
Detection Range (Increments)
Gas Sampling Diffusion
Power Source CR2450 coin-type lithium ion battery
Operating Temp. & Humidity -20°C to +50°C (no sudden changes)
(Approx. 15-minute temporary use environment: -20°C to +60°C) [no sudden changes] 10 to 90% RH (no condensation) (Approx. 15-minute temporary use environment: 0 to 95% RH) [no condensation]
Safety Rating ATEX, IECEx, CSA
RK-73-0022-01 GasWatch 3 For H2S With Wrist Band GW-3 (HS) 0 ~ 30 ppm 30 ~ 100 ppm
RK-73-0023-01 GasWatch 3 For CO With Wrist Band GW-3 (CO)
RK-73-0025-01
GasWatch 3 For CO With H2 Compensated Sensor & Wrist Band GW-3 (C-) 0 ~ 300 ppm
RK-73-0026-01 GasWatch 3 For CO/O2 Combination With Wrist Band GW-3 (CX) (Dual Sensor)
0 ~ 300 ppm O2: 0 ~ 25.0% Vol.
RK-72-0012-01 GasWatch 3 For O2 With Wrist Band GX-3 (O2) 0 ~ 25.0% Vol.
*GasWatch 3 with alligator clip models also available
Accessories & Calibration Equipment
NLB-F105325PN Calibration Gas 25 PPM H2S In N2, 34 Liter Steel Cylinder With CGA 600
NLB-H101650PN Calibration Gas 50 PPM CO In N2, 34 Liter Steel Cylinder With CGA 600
NLB-H1049200PA Calibration Gas 200 PPM H2 in Air, 34 Liter Steel Cylinder With CGA 600
NLB-H1066 Calibration Gas 100% N2, 34 Liter Steel Cylinder With CGA 600
NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
RK-81-1194 Calibration Adapter For GasWatch 3
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-500D Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders
• NLB-F105325PN
• NLB-517
• RK-81-1194
• NLB-H101650PN
• NLB-417
• RK-81-1194
• NLB-H101650PN
• NLBH1049200PA
• NLB-417
• NLB-H101650PN
• NLB-H1066
• NLB-417
• NLB-H1066
• NLB-417
• RK-81-1194
to +50°C (no sudden changes) 10 to 90% RH (no condensation)
• RK-06-1248RK-03
• NLB-500D
• RK-06-1248RK-03
• NLB-500D
• RK-81-1194
• RK-06-1248RK-03
• NLB-500D
• RK-81-1194
• RK-06-1248RK-03
• NLB-500D
• RK-06-1248RK-03
• NLB-500D
4 Versions Available LEL, O2, H2S & CO
03 Series Single Gas Clip-On Personal Monitor
The 03 Series single gas monitors are designed for LEL, O2, H2S or CO detection. Individuals need personal protection in hazardous areas at all times without adding extra bulky equipment and the 03 Series can provide that kind of protection at an affordable price.
Detection Principal
Applications
• Hazardous material
• Mining
• Tunnels
• Refineries / petrochemical
• Water / waste water treatment
• Pharmaceutical manufacturing
• Utilities
• Chemical plants
• Fire services
Features
Kit Includes
• GP-03, OX-03, HS-03 or CO-03 monitor
• Alligator clip
• Screwdriver
• (2) AAA alkaline batteries
• Rubber boot
• Quick reference card
• Small padded case
• Data log 5 to 30 hours with adjustable intervals
Safety Rating ATEX/IECEx approved, CSA classified, "C/US", as intrinsically safe, Class I, Division 1, Groups A, B, C, D
Model
HS-03
OX-03
GP-03
RK-73-0060-50 03 Series For CO CO-03 0 - 500 ppm
RK-73-0062-50 03 Series For H2S HS-03 0 - 100 ppm
RK-72-0010-50 03 Series For O2 OX-03 0 - 40% Vol.
RK-72-0037-50 03 Series For LEL GP-03 0 - 100% LEL
Accessories & Calibration Equipment
• NLB-H101650PA
• NLB-417
• RK-81-1146
• NLB-F105325PN
• NLB-517
• RK-81-1146
• NLB-H1066
• NLB-417
• RK-81-1146
• NLB-H197150LA
• NLB-417
SDM-03 Single Point Calibration Station
• RK-06-1248RK-03
• NLB-500D
• RK-06-1248RK-03
• NLB-500D
• RK-06-1248RK-03
• NLB-500D
• RK-81-1146
• RK-06-1248RK-03
• NLB-500D Part
RK-81-SDM03-01 SDM-03 Single Point Calibration Station For 03 Series With AC Adaptor, Flash Drive, USB Cable & Tubing
NLB-H101650PA Calibration Gas 50 PPM CO In Air, 34 Liter Steel Cylinder With CGA 600
NLB-F105325PN Calibration Gas 25 PPM H2S In N2, 34 Liter Steel Cylinder With CGA 600
NLB-H1066 Calibration Gas 100% N2, 34 Liter Steel Cylinder With CGA 600
NLB-H120815LA Calibration Gas 15% LEL Hexane In Air, 34 Liter Steel Cylinder With CGA 600
NLB-H197150LA Calibration Gas 2.5% CH4 (50% LEL) In Air, 34 Liter Steel Cylinder With CGA 600
NLB-H104950LA Calibration Gas 2.00% H2 (50% LEL) In Air, 34 Liter Steel Cylinder With CGA 600
NLB-H196950LA Calibration Gas 50% LEL Isobutane In Air, 34 Liter Steel Cylinder With CGA 600
NLB-417
NLB-517
0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
RK-81-1146 Calibration Adapter For 03 Series
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-500D Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders
Dräger Pac® Series - Fast & Robust Single Gas Detection Devices
The Dräger Pac® series is available with a wide variety of sensors. They provide fast and reliable gas detection to ensure life safety in your facility.
Features
• Easy to use and are manufactured using the latest technology
• Devices are very robust with a 360° alarm signal, clear color coding as well as a large, language-free display
• The green illuminating D-Light indicates whether the functionality of the device has been tested
• Each sensor variant of the Dräger Pac® series features a clear, well visible color coding, thereby minimizing the chance of mistakes
Dräger Pac® 6000
The Dräger Pac® 6000 disposable personal gas detector measures CO, H2S, SO2 or O2 reliably and precisely, even in the toughest conditions. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years of 24/7 operation (1 year for O2) with virtually no maintenance required.
Dräger Pac® 6000 For Carbon Monoxide (CO)
DR-8326368
DR-8327612
DR-8328273
Dräger Pac® 6000 For Hydrogen Sulfide (H2S)
Dräger Pac® 6000 For Oxygen (O2)
Dräger Pac® 6000 For Sulphur Dioxide (SO2) 0 -
*Fully configurable Dräger Pac® 6000 single gas monitor also available
Dräger Pac® 6500
• NLB-417
• DR-4594501
NLB-F105325PN
• NLB-517
• DR-4594501
• NLB-H107217VN
• NLB-417
• DR-4594501
• NLB-F107910PN
• NLB-517
• DR-4594501
The robust Dräger Pac® 6500 is your reliable companion under tough conditions. The personal single-gas detection device measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a replaceable battery also ensure safety. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery for 2 years of 24/7 operation (1 year for O2). Part Number
• DR-4594501 DR-8327616 Dräger Pac® 6500 For Oxygen (O
• NLB-H107217VN
• NLB-417
• DR-4594501 DR-8328274
Dräger Pac® 6500 For Sulphur Dioxide (SO2)
*Fully configurable Dräger Pac® 6500 single gas monitor also available
• NLB-F107910PN
• NLB-517
• DR-4594501
Dräger Pac® 8000
With the robust Dräger Pac® 8000, you’ll be well equipped for tough conditions: this non-disposable, personal single-gas detection device is a reliable and precise instrument, which detects hazardous concentrations of twenty nine different gases, including special gases like NO2, O3 or COCl2. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery for 2 years of 24/7 operation.
DR-8326350
DR-8328275
Dräger Pac® 8000 For Nitric Oxide (NO)
Dräger Pac® 8000 For Nitrogen Dioxide (NO2 LC)
DR-8326351 Dräger Pac® 8000 For Carbon Dioxide (CO2)
DR-8326352 Dräger Pac® 8000 For Chlorine (CL2)
DR-8328276 Dräger Pac® 8000 For Hydrogen Cyanide (HCN)
DR-8328277 Dräger Pac® 8000 For Ammonia (NH3)
DR-8326355 Description Dräger Pac® 8000 For Phosphine (PH3) 0 -
DR-8326356 Dräger Pac® 8000 For Organic Vapours (OV)
DR-8326357 Dräger Pac® 8000 For Organic Vapours (OV-A)
DR-8326359 Dräger Pac® 8000 For Ozone (O3)
DR-8326360 Dräger Pac® 8000 For Phosgene (COCl2)
• NLB-F166025PN
• NLB-517
• DR-4594501
• NLB-F106710PN
• NLB-517
• DR-4594501
• NLB-H10132.5VN
• NLB-417
• DR-4594501
• NLB-ZB10175PN
• NLB-517SS
• DR-4594118
• NLB-F105110PN
• NLB-517
• DR-4594501
• NLB-F100550PN
• NLB-517SS
• DR-4594118
• NLB-517
• DR-4594501
• NLB-517
• DR-4594501
• NLB-F104010PN
• NLB-517
• DR-4594501
Contact us for more information
Contact us for more information *Fully configurable
Dräger Pac® 8500
The Dräger Pac® 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or a Dräger dual sensor. The dual sensors provide the option of measuring two gases at once: either H2S with CO or O2 with CO. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery. Part
• DR-4594501
•
• DR-4594501
Part Number Description
DR-8325646 GasVision 7 Software License
DR-5600704 USB Communication Cradle For Dräger Pac® Monitors
DR-8318587 Communication Cradle & USB Cable
DR-8317410 Dräger Pac® Bump Test/Calibration Station (Gas Cylinder Sold Separately)
DR-8318588 Bump Test/Calibration Adaptor (Hose, Regulator & Gas Cylinder Sold Separately)
DR- 8321881 Dräger X-dock® 5300 Pac Station, Set Consisting Of One Master (Up To 3 Gases) With Power Supply & One Instrument Module For the Dräger Pac® Series 6000/6500/8000/8500 (Regulator Sold Separately)
NLB-H1016100PN Calibration Gas 100 PPM CO In N2, 34 Liter Steel Cylinder With CGA 600
NLB-F105325PN Calibration Gas 25 PPM H2S In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-H107217VN Calibration Gas 17% O2 In N2, 34 Liter Steel Cylinder With CGA 600
NLB-F107910PN Calibration Gas 10 PPM SO2 In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-F166025PN Calibration Gas 25 ppm NO In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-F106710PN Calibration Gas 10 ppm NO2 In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-H10132.5VN Calibration Gas 2.5% Vol. CO2 In N2, 34 Liter Steel Cylinder With CGA 600
NLB-ZB10175PN Calibration Gas 5 ppm CL2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-F105110PN Calibration Gas 10 ppm HCN In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-F100550PN Calibration Gas 50 ppm NH3 In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-F2199.5PN Calibration Gas 0.5 ppm PH3 In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-F104010PN Calibration Gas 10 ppm Ethylene Oxide (For OV Sensors) in N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-F105325PM73 Calibration Gas 25 PPM H2S / 100 PPM CO / 2.5% CH4 (50% LEL) / 17% O2 In N2, 34 Liter Aluminum Cylinder With CGA C-10
NLB-H1049500PA Calibration Gas 500 ppm H2 In Air, 34 Liter Steel Cylinder With CGA 600
NLB-417
NLB-517
0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
0.5 LMP Regulator With Gauge & Knob For Cylinders With CGA C-10
DR-4594501 10 ft Tygon® Sampling Hose
DR-4594118 5 ft PTFE Lined Reactive Gas Sampling Hose
NLB-500D Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders
Fully Configurable Dräger X-am® 5100 Single Gas Monitor
Dräger X-am® 5100
The Dräger X-am® 5100 is a small lightweight single gas monitor which is specifically designed for the requirements of personal monitoring. It can be equipped with an electrochemical sensor for hydrazine, hydrogen fluoride / hydrogen chloride or hydrogen peroxide.
For manufacturing petrochemical products, aseptic packing, or handling of rocket fuel: the Dräger X-am® 5100 portable single-gas detector ensures safe handling of HF, HCl, H2O2 or hydrazine - thanks to proven Dräger sensor technology and a device design which is perfectly customized to reactive gases.
DR-8322785 High Capacity NiMh Battery & Charger Kit
Accessories
Part Number Description
DR-8317409 USB-IR Communication Cable
DR-8325646 GasVision 7 Software License
DR-6806291 Calibration Adapter With 3 ft Of Tubing
DR-4543755 Deluxe Instrument Transport Case For X-am® 1/2/5000
DR-4543936 High Visibility Yellow Heavy-Duty Transport Case
DR-4594631 Nylon Transport Case
GX-2009 Personal Multi-Gas Monitor
The GX-2009 simultaneously monitors and displays LEL, O2, CO, and H2S. The GX-2009 is also functional with the SDM-2009 single calibration station and the Data Cal 2000 instrument maintenance system. It is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies.
Applications
• Personal monitoring
• Confined spaces
• Refineries / petrochemical
• Oil & gas
• Utilities
• Hazardous material
• Water/waste water treatment
• Fire services
• Construction Features
Kit Includes
• GX-2009 monitor
• Wrist strap
• Alligator clip
• 115/220 VAC adapter for charger
• (2) NiMH battery set with hardware
• BC-2009 charging station base only
• Simultaneous detection of 4 gases, LEL, O2, H2S & CO
• STEL and TWA readouts
• Dual audible alarm ports (95 db @ 30 cm)
• 3 visual alarm LED’s
• Vibration alarm
• Calibration and bump test lock out or reminder controls
• Large capacity data logging standard
• 8 alarm trends
• Log time range of 10 to 300 hours
• 100 calibration records stored
• Automatic backlighting at alarm
• Impact resistant rubber over-mold body, RFI shielded body
• IP-67 water-resistant/dustproof design
Detection Principal Catalytic Combustion Galvanic Cell Electrochemical Cell
Detection Range (Increments) 0 - 100% LEL (1% LEL)
Accuracy (Whichever Is Greater) ± 5% of reading or ±2% LEL ± 0.5% O2 ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 5 ppm CO
Sampling Method Diffusion sampling standard / hand aspirator or motorized pump optional
Power Source (2) direct charging NiMH batteries
Operating Temp. & Humidity -20°C ~ +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing (splash resistant)
Safety Rating IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; (optional MSHA version also available)c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
RK-72-0314RKC GX-2009 4-Gas Personal Monitor For LEL/O2/H2S/CO With Alligator Clip & 115/220 VAC Charger
*Other configurations are also available
*GX-2009 personal multi-gas monitor mining version also available
Accessories & Calibration Equipment
Part Number Description
• NLB-Z105325PM51
• NLB-517
• RK-81-1107RK
• RK-06-1248RK-03
• RK-03NLB-505
RK-81-SDM2009-01 SDM 2009 Single Point Calibration Station For GX-2009 With AC Adaptor, Flash Drive, USB Cable & Tubing
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
RK-81-1107RK Rubber Calibration Sample Cap For GX-2009
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders
PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)
Model GX-2009
World’s Smallest & Lightest 4 Gas Monitor
GX-3R Personal 4-Gas Confined Space Monitor
The GX-3R simultaneously monitors and displays LEL combustibles, O2, CO (H2 compensated CO also available) and H2S. The LEL sensor has a unique design with two active filaments in one sensor to increase its resistance to silicone poisoning. If one filament gets poisoned the second filament takes over.
Features
• Simultaneous detection of 4 gases: LEL, O2, H2S & CO (H2 Compensated CO sensor available)
• Simple 2-button operation
• 3 user adjustable alarm levels
• Audible, visual & vibration alarms
• Non-compliance indicator
• Large LCD Auto-backlit display
• Field replaceable sensors & filters
• Impact resistant body with removable rubber boot
• Water and dust resistant design, IP66/68
Applications
• Personal monitoring
• Confined spaces
• Refineries / petrochemical
• Oil & gas
• Utilities
• Hazardous material
• Water/waste water treatment
• Fire services
• Construction
Model GX-3R
Kit Includes
• GX-3R monitor
• Wrist strap
• Alligator clip
• Rubber boot
Gas Detected Carbon Monoxide (CO) H2 Compensated Carbon Monoxide (CO) Hydrogen Sulfide (H2S) Hydrogen Sulfide (H2S) Only
• Calibration adapter
• Li-Ion battery pack
Combustible Gases (Methane (CH4) as standard Oxygen (O2)
Sensor Slot 1 2 3
Detection Principal
Detection Range (Increments) 0 ~ 2,000 ppm (1 ppm)
• 0 ~ 2,000 ppm CO (1 ppm)
0 ~ 200.0
Accuracy (Whichever Is Greater) ± 5% of reading or ± 2 ppm CO • ± 5% of reading or ± 5 ppm CO
Power Source
Li-Ion battery pack
Sampling Method Diffusion sampling standard / hand aspirator or motorized pump optional
RK-72-RA-C GX-3R 4-Gas Personal Monitor For LEL/O2/Combo H2S & CO With Li-Ion Battery Pack & 100-240 VAC Charger • NLB-Z105325PM51
• NLB-513
• RK-06-1248RK-03
• NLB-505
*Other configurations are also available
Accessories & Calibration Equipment
Part Number Description
RK-81-SDM3R101 SDM-3R Calibration Station With 1 Solenoid, AC Adapter, Flash Drive, USB Cable & Tubing
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-513 0.25 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)
*Optional RP-3R clip-on sample drawing pump also available.
World’s Smallest & Lightest 5 Gas Monitor
GX-3R Pro Personal 4-Gas + Toxic Gas Monitor With Bluetooth
The GX-3R Pro simultaneously monitors and displays 5 different gases. In addition to monitoring standard confined space gases LEL, O2, CO, & H2S, the GX-3R Pro has a 5th channel where you can add infrared or toxic sensors. Two of the four sensor slots have interchangeable sensors providing flexible configurations, which can easily be changed in the field.
The GX-3R Pro utilizes Bluetooth communication to display direct gas readings from the instrument to a phone app, which is available free on either iOS or Android phones. Automatic notifications can be programmed to send text or email messages, if there is an alarm event from the GX-3R Pro.
Accuracy (Whichever Is Greater) ± 5% of reading or ± 5 ppm CO ± 5% of reading or ± 2 ppm H2S
5% of reading or ± 2 ppm H2S ± 5% of reading or ± 2 ppm CO ± 5% of reading or ± 2 % LEL
Sampling Method Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)
RK-72-PAA-C GX-3R Pro 5-Gas Personal Monitor For LEL/O2/Combo H2S & CO/ppm CO2 With Li-Ion Battery Pack & 100-240 VAC Charger
*Other configurations are also available
Accessories & Calibration Equipment
Part Number Description
Calibration Equipment
• NLB-Z105325PM51
• NLB-Z10135000PN
• NLB-513
• RK-06-1248RK-03
• NLB-505
RK-81-SDM3R201 SDM-3R Calibration Station With 2 Solenoids (For 2 Cylinders), AC Adapter, Flash Drive, USB Cable & Tubing
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-Z10135000PN Calibration Gas 5000 PPM CO2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-513 0.25 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)
*Optional RP-3R clip-on sample drawing pump also available
Remote Sample Drawing Pump For GX-3R & GX-3R Pro
RP-3R Clip-On Sample Drawing Pump
The RP-3R are compact, battery operated, motorized sample drawing pumps which attach to either the GX-3R or the GX-3R Pro to change them from diffusion operation to sample drawing operation. The model RP-3R pumps and the GX-3R or GX-3R Pro gas monitor make a complete solution for confined space entry.
Features
• Attaches to the GX-3R in seconds (RP-3R Pro for the GX-3R Pro)
• Compact and lightweight
• 10 hours of operation in normal mode (higher flow mode)
• 16 hours of operation in lower-flow mode (ECO mode)
• Audible and visual alarms for low flow and low battery conditions
• Pilot light to confirm operation
• Quick disconnect fitting for hose connection
• Hoses available up to 100’ length
• Rugged and proven RKI reliability
Kit Incudes
• 4" tapered red rubber nozzle
• "AA" Alkaline battery
• Hydrophobic filters
Model RP-3R
Flow Rate Higher flow mode: 0.5 l/m
Alarm Display
Power Supply
Continuous Operation
l/m
Low flow alarm: Flow blinks YELLOW Low battery alarm: Power LED blinks GREEN
Power Source Li-Ion battery pack or (3) "AA" Alkaline battery pack (interchangeable)
Operating Temp. & Humidity -20°C to +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing
Safety Rating ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)
Part Number Description
RK-72-0292-22-C GX-2012 4-Gas Detector For LEL/O2/H2S/CO With Li-Ion Battery Pack & 100-240 VAC Charger
*Other configurations are also available
Accessories & Calibration Equipment
Part Number Description
Calibration Equipment
• NLB-Z105325PM51
• NLB-8C10
• RK-06-1248RK-03
• NLB-505
RK-81-SDM2012-01 Single Point Calibration Station For GX-2012 & Gas Tracer With AC Adaptor, Flash Drive, USB Cable & Tubing
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-8C10
Demand Flow Regulator For Cylinders With CGA C-10
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders PC-915-1001 Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)
*Optional RP-3R clip-on sample drawing pump also available
Model
Excellent For Gas Line Purge Testing & Detection Of Small Gas Leaks
Gas Tracer Confined Space Multi-Gas / Leak Detector
Built around high-quality micro-sensor technology, the Gas Tracer is RKI’s smallest personal 5-sensor monitor with a built in sample pump.
Features
• Monitors ppm LEL, % Vol. CH4, O2 and CO
• PPM leak detector, detects down to 10 ppm CH4
• "Leak tracker" audible/visual alarm mode for CH4 and CO
• 0 - 100% Vol. CH4 option
• Auto-ranging display of % LEL and % volume
• Barhole test mode
• Bump test reminder option
• Snap-logging - on demand data recording
• Pump pause on demand extends battery life
• Status indicators: pump active, microprocessor status and battery level
• Internal sample drawing pump with up to 50 ft range
• Vibration, visual and audible alarms
• Automatic backlight during alarms
• Calibration reminder with lock out option
• Li-Ion or alkaline battery packs (interchangeable)
• Alarm latching or non-latching
• High impact protective rubber over molding
• Up to 600 hours of data logging with alarm trends
Detection Range 0 ~ 100% LEL 0 ~ 100% Vol. 0 ~ 5000 ppm optional 10,000 ppm range version available 0 ~ 40% Vol. 0 ~ 500 ppm
Accuracy (Whichever Is Greater) ± 5% of reading or ± 2% LEL ± 5% of reading or ± 2% of full scale CH4 ± 10% of reading or ± 50 ppm CH4 ± 5% O2 ± 5% of reading or ± 5 ppm CO
Power Source Li-Ion battery pack or (3) "AA" Alkaline battery pack (interchangeable)
Operating Temp. & Humidity -20°C to +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing
Safety Rating ATEX, TIIS, IECEx, CE, or optionally: c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D Note: Either ATEX (USA and worldwide) or CSA (Canada) version must be specified when ordering.
*Other configurations are also available Model Gas Tracer
Accessories & Calibration Equipment
Part Number
RK-81-SDM2012-01
NLB-J1971500PA
NLB-J1971500PA
• NLB-Z1971
• NLB-J197150LM4
• NLB-8C10
• RK-33-2001RK-01
• RK-06-1248RK-03
• NLB-500C
Description
Single Point Calibration Station For GX-2012 & Gas Tracer With AC Adaptor, Flash Drive, USB Cable & Tubing
Calibration Gas 500 PPM CH4 In Air, 103 Liter Steel Cylinder With CGA C-10
NLB-Z1971 Calibration Gas 100% Vol. CH4, 58 Liter Aluminum Cylinder With CGA C-10
NLB-J197150LM4 Calibration Gas 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 103 Liter Steel Cylinder With CGA C-10
NLB-8C10
RK-33-2001RK-01
RK-06-1248RK-03
Demand Flow Regulator For Cylinders With CGA C-10
6" Humidifier Tube Assembly For Cal Kits With 3/16" Tubing On Ends
3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-500C Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 3 Cylinders
PC-915-1001
Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)
Features
• 0.01 - 50 ppm with 10.0 eV PID lamp and pre-filter tube
• Benzene Select Mode takes timed samples using pre-filter tube
• Benzene Filter Tube Holder
• Long break through times for Benzene filter tubes
• 4 PID options: 10.6 eV (2 ranges), 10.0 eV, and 11.7 eV lamp
• Easily switch VOC target gas
• Available with both 10.0 & 10.6 PID sensors
• Monitor up to 6 gases
• 2 smart sensor slots auto recognize PID, IR, and super toxic sensors
• Internal sample pump
& Accessories
Best Seller!
GX-6000 Up To 6-Gas, Sample Draw Portable Monitor With Choice Of PID, IR & Super Toxic Sensors
The GX-6000 simultaneously monitors up to 6-gases. In addition to the standard 4 confined space gases which include LEL, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. It can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. A benzene-specific version is also available using a pre-filter tube for detecting low levels of benzene.
-20°C ~ +50°C (-4°F to 122°F ), 0- 95% RH non condensing
Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class: Ex ia IIC T4 Ga Others: CE Marking
Part Number Description Calibration Equipment
RK-72-6ABX-C GX-6000 For LEL/ O2/H2S/CO/VOCs (0-6,000 ppm PID) With Li-Ion Battery Pack & 100-240 VAC Charger
*Other configurations are also available
• NLB-J1055100PA
• NLB-Z105325PM51
• NLB-8C10
• RK-06-1248RK-03
• NLB-505
Accessories & Calibration Equipment
Part Number Description
RK-81-SDM6000-01 SDM-6000 Calibration Station For GX-6000 With Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable For PC, 10’ Exhaust Tubing & Single Unit AC Adapter
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-J105100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10
NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders
PC-920-1001 Black NANUK™ Case 920 With Cubed Foam (Other Colors Available Upon Request)
Over 400 Gas Monitoring Configurations
EAGLETM Up To 6-Gas Portable Monitor
The EAGLETM is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, continuous operation adapters, remote alarms and strobes, and dilution fittings, etc.
Applications
• Personal monitoring
• Confined space entry
• Refineries / petrochemical
• Chemical plants
• Hazardous material
• Water/waste water treatment
• Fire services
• Mining
• Line purge testing
• Transformer testing
• Leak investigation
Features
Kit Includes
• EAGLE
• 10" hydrophobic probe (standard gas versions and some super toxic versions only)
• 5 ft polyurethane hose (standard gas versions and some super toxic versions only)
• Shoulder strap with RKI logo
• Internal hydrophobic filter
• (4) "D" alkaline batteries
• Simultaneous detection of up to 6 different gases
• IR Sensors available for CO2, % LEL CH4 or HC, % Vol. CH
• Wide range of toxic gases
• PPM / LEL hydrocarbon detection
• CH4 elimination switch for environmental applications
• Two alarm levels per channel plus TWA and STEL alarms for toxic channels
• Powerful long-life pump up to 125' range with filters
• Dual hydrophobic filters (most versions)
• Transformer testing version available
Part Number Description
RK-72-5401RK EAGLETM For LEL & PPM/O
*Other configurations are also available
**Optional & ONLY used if the customer’s intent is to use the Methane elimination mode
Accessories & Calibration Equipment
Part Number Description
RK-81-SDME2-01 SDM-E2 Calibration For EAGLETM & EAGLETM 2, With AC Adaptor, Flash Drive, USB Cable & Tubing
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-J120815LA Calibration Gas 15% LEL Hexane In Air, 103 Liter Steel Cyl. With CGA C-10
NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505 Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders
RK-49-2150RK-01 Ni-Cad Batteries & 115 VAC Charger For EAGLETM
RK-57-0012RK-01 Factory Installed Data Logging Board For EAGLETM (Part # RK-82-5007RK Also Required)
RK-75-0001RK Factory Installed External Methane Elimination Switch For EAGLETM
RK-33-0156RK-01 Replacement Hydrophobic Filter Element For EAGLETM & EAGLETM 2 Probe, 5/Pack PC-925-1001 Black NANUK™ Case 925 With Cubed Foam (Other Colors Available Upon Request)
Hydrocarbons (CH4, std)
Carbon Monoxide (CO)
Hydrogen Sulfide (H2S)
EAGLETM
Confined Space Gases
0 - 100% LEL ± 5% of reading or ± 2% LEL
0 - 50,000 ppm ± 50 ppm or ± 5% of reading
0 - 40% Vol. ± 0.5% O2
0 - 500 ppm ± 5% of reading or ± 5 ppm CO
0 - 100 ppm ± 5% of reading or ± 2 ppm H2S
Super Toxics & Other Gases
) 0 - 75 ppm
0 - 1 ppm
0 - 200 ppb
0 - 3 ppm
Chlorine Dioxide (ClO2)
Hydrogen Fluoride (HF)
Hydrogen Chloride (HCl)
Hydrogen Cyanide (HCN)
0 - 1 ppm
0 - 5 ppm
0 - 9 ppm
0 - 15 ppm
0 - 30 ppm
Hydrogen Peroxide (H2O2) 0 - 3 ppm
Hydrogen Selenide (H2Se) 0 - 0.2 ppm
Hydrogen Sulfide (H2S)
0 - 1 ppm
0 - 30 ppm
Nitrogen Dioxide (NO2) 0 - 15 ppm
Ozone (O3)
Nitric Oxide (NO)
0 - 1 ppm
0 - 100 ppm
Phosphine (PH3) 0 - 1 ppm
Silane (SiH4) 0 - 15 ppm
Sulfur Dioxide (SO2) 0 - 6 ppm
Carbon Dioxide (CO2)
0 - 5,000 ppm
0 - 10,000 ppm
0 - 5% Vol.
0 - 20% Vol.
0 - 60% Vol.
Methane (CH4) 0 - 100% LEL
Isobutane (iC4H10)
0 - 100% Vol.
0 - 100% LEL
0 - 30% Vol.
Infrared (IR Sensors)
± 10% of reading or ± 5% of full scale
± 5% of reading or ± 2% of full scale
Detection Principal Catalytic Combustion, Electrochemical Cell, Galvanic Cell & Infrared
Sampling Method
Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.
Power Source (4) Alkaline or Ni-Cad, size "D" batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines.)
Operating Temp. & Humidity -10°C to 40°C (14°F to 104°F), 0 to 95% RH, non-condensing
Safety Rating
Intrinsically Safe, Class I, Division 1, Groups A, B, C, D. CSA (C / US) and UL classified (most versions)
Soaring To New Heights! The Legacy Continues With The EAGLETM 2
EagleTM 2 Up To 6-Gas Portable Monitor With Choice Of PID
The EAGLETM 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. The EAGLETM 2 available features include a PID sensor for detecting high or low ppm levels (0 - 50 ppm & 0 - 2,000 ppm) of VOC gases; % Vol. capability for CH4 and H2 using a TC (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % Vol.), CH4 or hydrocarbons in LEL and % Vol. ranges; CH4 elimination feature for environmental applications; and a variety of super toxic gases. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, etc.
Applications
• Personal monitoring
• VOC monitoring
• Confined space entry
• Refineries / petrochemical
• Chemical plants
• Hazardous material
• Water/waste water treatment
• Fire services
• Mining
• Line purge testing
• Transformer testing
• Leak investigation
Features
• Simultaneous detection of up to 6 different gases
• PPM, % LEL, or % Vol. auto-ranging combustible detection
• Specialty Sensors
• PID (Photoionization Detector): low or high range for VOC detection, fence electrode technology for humidity and contamination resistance
SDM-E2 Calibration For EAGLETM & EAGLETM 2, With AC Adaptor, Flash Drive, USB Cable & Tubing
NLB-Z105325PM51 Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10
NLB-J105100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10
NLB-8C10 Demand Flow Regulator For Cylinders With CGA C-10
RK-06-1248RK-03 3/16" I.D. x 5/16" O.D. Polyurethane Calibration Tubing, 3 ft
NLB-505
RK-49-2175RK-01
Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders
Factory Installed 100-240 VAC Battery Charger With (4) "C" NiMH Batteries For EAGLETM 2
RK-33-0156RK-01 Replacement Hydrophobic Filter Element For EAGLETM & EAGLETM 2 Probe, 5/Pack PC-925-1001 Black NANUK™ Case 925 With Cubed Foam (Other Colors Available Upon Request)
Gas Detected Detection Range Accuracy (Whichever Is Greater)
Sampling Method Powerful, long-life internal pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.
Power Source (4) alkaline or NiMH, size "C" batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines.)
Operating Temp. & Humidity -20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing
Safety Rating Intrinsically Safe, Class I, Groups A, B, C, D. Approvals: CSA / CE
* The EAGLETM 2 can be configured with up to 6 gas sensors from the above list
ne
EAGLETM 1
The Major differences
• Ability to detect for more different gases with regard to toxic inorganic compounds, using the large toxic, electrochemical sensors
• Limited as to what sensor configurations it can do, especially when 5 or 6 sensors are considered
• Datalogging is no longer supported
• Longer run time using "D" size batteries (to access the NiCad rechargeable batteries, you must lift off the top case)
• Available for approx. 2 more years
Between The EAGLETM 1 & The EAGLETM 2
VS
EAGLETM 2
• PID capability
• Thermal Conductivity sensor capability, % Vol. as an option to the IR sensors
• Hydrogen specific capability for the % LEL sensor
• Datalogging capabilities is supported
• Shorter run time using "C" size batteries (exterior Alkaline or NiMH battery pack)
Model
The World’s Smallest & Lightest Personal VOC Detector
Cub Personal VOC Detector
The Cub personal PID monitor accurately detects volatile organic (VOC) and total aromatic compounds (TAC). With market leading parts-per-billion (ppb) sensitivity, Cub gives an early warning of hazardous gases, including benzene, before they reach levels which are harmful. Also available is the CubTAC ppm variant with 10.0 eV lamp for the detection of total aromatic compounds (TACs), including benzene.
Features
• Available in three distinct variants: ppm, ppb and TAC mode
• ppm or ppb Cub detects a wide range of over 480 VOCs
• CubTAC detects total aromatic compounds (TACs) down to ppb levels
• Detection range:
• Cub ppm model: 0.1 - 5,000 ppm
• Cub ppb model: 1 ppb - 5,000 ppm
• CubTAC model: 10 ppb - 5,000 ppm
• Optional software upgrade from ppm to ppb
• Lamp:
• Cub ppm & ppb model: 10.6 eV
• CubTAC model: 10.0 eV
• Humidity resistance technology
• Data logging 30,000 readings
• Multi-logging including full list of gases selectable from PC software
• LED audio & vibrate alarm
• Pre-programmed TWA & STEL alarm* (only available for ppb model)
IS-CUBUPG-M2B Cub Software Upgrade From PPM To PPB
IS-LA4TM600 10.6 eV PID Lamp
IS-LA4TS600 10.0 eV PID Lamp
IS-A-846267 White Fence Electrode Stack
IS-A-846417 White With Gold Spot Fence Electrode Stack
IS-871026 PTFE Filter Membrane, Each
IS-A-31063 PID Lamp Cleaning Kit
IS-871200 Calibration Cup
NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600
NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600
NLB-Z11145PA Calibration Gas 5 PPM Benzene In Air, 58 Liter Aluminum Cyl. With CGA C-10
NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
NLB-514 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
or NLB-517
TIGER XT COMPARISON CHART HANDHELD
VOC
Low Cost VOC Detection With Market Leading Accuracy
Tiger XTL Handheld VOC Detector
The Tiger XTL accurately detects volatile organic compounds (VOCs) from 0 - 5,000 ppm with a 0.1 ppm minimum sensitivity, has the fastest response time on the market of just two seconds, and is as quick to clear down. Its revolutionary, patented PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.
Applications
• Environmental monitoring
• Soil contamination detection
• VOCs in landfill
• IAQ measuring industrial volatiles
• Health & safety
• Confined space entry
• First response (screening)
• Wing tank entry
• VOC leak detection
• Fumigation gases
• Fugitive emissions
• Medical gases in hospitals
• Fire and Arson Investigation
Features
• Detection range: 0.1 - 5,000 ppm
• Lamp:
• 10.6 eV (standard)
• 10.0 eV and 11.7 eV (optional also available)
• Patented humidity resistance technology to 99% RH – no compensation needed
• Push-to-log data logging stores up to 80,000 data points in up to 128 user selectable zones
• User selectable response factors for direct concentration readout
LPM Regulator With Gauge & Knob For Cylinders With CGA 600
Handheld Humidity-Resistant VOC Detector
Tiger XT Handheld VOC Detector
The Tiger XT provides a dynamic detection range of 0 - 20,000 parts per million (ppm) with a minimum sensitivity of 0.001 ppm (1 ppb), offering the widest measurement range of any other volatile organic compound (VOC) detector on the market. Its revolutionary, PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.
Applications
• Environmental monitoring
• Soil contamination detection
• VOCs in landfill
• IAQ measuring industrial volatiles
• Leakage in fuel & chemical storage
• Health & safety
• STEL & TWA monitoring
• Confined space entry
• First response (screening)
• Wing tank entry
• VOC leak detection
• Fumigation gases
• Fugitive emissions
• Medical gases in hospitals
• Fire and Arson Investigation
Kit Includes
• Tiger XT instrument (PPM or PPB) with rubber boot
• Lanyard (wrist strap)
• PTFE filter disc (dust filter)
• Carbon zero filter assembly
• PID lamp cleaning kit
• Removal tool MiniPID stack
Features
• Available in two distinct variants: ppm and ppb
• Detection range:
• Tiger ppm model: 0.1 - 20,000 ppm
• Tiger ppb model: 1 ppb - 20,000 ppm
• Optional software upgrade from ppm to ppb
• Lamp:
• Tiger ppm and Tiger ppb models: 10.6 eV (standard)
• 10.0 eV and 11.7 eV (optional also available)
• Patented humidity resistance technology to 99% RH – no compensation needed
• Push-to-log and multi-logging stores up to 120,000 data points including date/time
• Internal gas table with over 700 VOCs and toxic compounds
• Flashing LED & audible alarm
• Selectable vibrating alarm
• Pre-programmed TWA & STEL alarm* (only available for ppb model)
NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600 Accessories & Calibration Equipment *Other
Cylinder With CGA
Instant VOC Detection For Fire & Arson Investigation
Tiger XTL & Tiger XT Handheld VOC Detector With Fire Investigation Kit
The Tiger XTL & Tiger XT PID has been specifically designed to provide you with all the tools for a convenient, easy-to-use solution for the detection of volatile organic compounds (VOCs) within fire and arson investigation applications. Both models incorporate Ion Science’s market-leading PID technology with patented fence electrode system. The advanced three-electrode format ensures increased resistance to humidity and contamination for ultimate reliability and accuracy in the field, as well as reduced drift issues and extended run time.
Kit Includes
• Tiger XTL or Tiger XT instrument with rubber boot
• 1 m flexi-probe
• Bump test pen
• Exhaust barb which can be connected to a collection bag
• (10) PTFE filters
• "AA" Tiger XTL or Tiger XT battery pack for emergency power source
• Charging cradle & travel charge adaptor
• Mains adaptor
• USB cable
• Quick start guide
• Rugged case
NLB-414 or NLB-417
* Used to calibrate for ppb measurements
** Used to calibrate for ppm measurements
Accessories & Calibration Equipment
Number
IS-A-861632 Premium PTFE Filters, 10/Pack NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10
NLB-414 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
NLB-417 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600
Benzene & Total Aromatic Compound (TAC) Detection In One Instrument
Tiger XT Select Benzene & TAC VOC Detector
The Tiger XT Select is a revolutionary hand-held gas detector for the rapid, accurate detection of benzene and Total Aromatic Compounds (TACs). Utilizing the high output Ion Science 10.0 eV detection system, a reading for TACs is seen immediately on start-up. Should aromatics be detected, an ION Science benzene pre-filter tube can be easily attached to ensure fast detection and selective measurement of benzene. Its revolutionary, PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.
Applications
• Confined space entry
• Pre-screening during refinery and plant maintenance
• Marine spill response
• Refinery down-stream monitoring
• Hazardous material response
• Total aromatic compounds (TACs)
• Detection at loading docks and barge operations
Features
• Available in two distinct variants: ppm and ppb
• Selectively detects benzene with benzene pre-filter tubes
NLB-H105510PA Calibration Gas 10 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10
NLB-H1055100PA Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10 NLB-Z11145PA Calibration Gas 5 PPM Benzene In Air, 58 Liter Aluminum Cyl. With CGA C-10
NLB-514 0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
NLB-517 0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10
NLB-J1055100PA
• NLB-Z11145PA
• NLB-514 or NLB-517
NLB-J105510PA*
• NLB-J1055100PA**
• NLB-Z11145PA
• NLB-514 or NLB-517
Also Available... Fixed Systems
Detector Heads
Specialty Portable Monitors
Fixed Systems
VOC Detectors
Leak Detectors
Falco Diffused
Falco Pumped
2
Odour Destroyer & Neutralizer
Aquakem™ Odour Skunk™
Odour SkunkTM is a plant-based product that eliminates nasty odours at the source. While many products only mask offensive odours with strong fragrances, Odour SkunkTM will neutralize them.
Applications
• Residential
• Commercial
• Industrial
• Wastewater
• Chemical odor control
• Food processing
• Sports
• And many more…
Features
• Captures and neutralizes odours
• Non-toxic
• Biodegradable
• Non irritating
• Available without fragrance (minimum quantities required)
Removal Of Odours, Gaseous Or VOC Particulates
Sampson™ Odour Removal Pleated Air Filters
Sampson™ odour removal carbon pleated filters are designed for the control of intermittent odour problems. This filter can also be a low cost method to verify the potential effectiveness of carbon for controlling an odor problem.
Applications
• Office buildings
• Hospitals
• Airports
• Food courts
• Manufacturing facilities
Features
• Wide range of configurations and sizes available
• Available in 1", 2" and 4" depths
• MERV 5, 6
• Carbon enhanced pleated filter for odor removal
• Can be easily adapted to existing HVAC systems
Cannabis Odour Control Media
CannaSorber™
ERE’s special blend air phase media specifically designed to treat odours from cannabis.
Applications
• Curing/drying rooms
• Cutting/deflowering rooms
• Extraction and packaging rooms
• Proprietary blend of selective media for odour and VOC
• Adsorbs terpenoids
• Adsorbs terpenes
• Adsorbs VOCs
• Has a capacity of up to 60% of its own weight
• Particle size: 4 x 8 US mesh
• CCl4 activity min. (ASTM D-3467): 60
• Proprietary blend active ingredient, % wt. min.: 6.0
• Bulk Density lb/ft3: 39
• Bacteria mold controlled media
Features
• High Capacity (MERV 10)
• Available in 1”, 2” & 4” depths
• 100% synthetic pleated media achieves exceptionally high levels of efficiency
• Does not rely on electrostatic charge
• Low resistance to air flow means minimal energy costs
• Moisture resistant and will not promote microbial growth
• Excellent pre-filter for higher efficiency air filters
• Effectively removes airborne irritants
• Protects cooling coils & ductwork of HVAC system
Applications
• Prefilter for high efficiency filters
• Office and retail
• Manufacturing and distribution
• Government and education facilities
• Doctor offices, assisted living facilities and hospitals
• Hotels and airports
• Single and multi-family housing
* Contact customer service for additional sizes and information
Available Air Filters For Many Applications
•
•
UltraSorber-BCTM
The UltraSorber-BCTM activated carbon manufactured from selected grades of bituminous coal ideally suited for VOC gas adsorption. possesses both a high surface area and a large internal pore volume. These properties give the carbon not only high VOC adsorption capacities, but also highly retentive for retaining and preventing the desorption of previously adsorbed organic compounds. Being manufactured from high rank coals results in an inherently low ash content, making these carbons ideally suited for critical gas phase adsorption applications.
Features
• Specifically manufactured from select grades of bituminous coal
• Excellent for applications from general odour abatement to solvent adsorption and recovery
• High surface area and broad pore structure
• Less frequent changeouts = cost effective
• Lower pressure drops
• Packaged in bags, totes, and super sacs
Applications
• Solvent recovery operations
• Chemical process applications
• VOC control from air strippers, soil vapor extraction and air sparge systems
• Control of tank vent emissions
• HVAC
• Odor control
• As a substrate for odor control carbon manufacture and as a catalyst support
UltraSorber-CNSTM
The UltraSorber-CNSTM is a high activity, granular activated carbon manufactured from selected grades of coconut shell. The granular shape of this carbon maximizes its geometric surface area, significantly increasing surface and pore diffusion rates and thereby increasing its effectiveness for the adsorption of VOCs with a short contact time. The high surface area and predominately microporous pore size distribution further enhance the effectiveness of this coconut shell based carbon.
Features
• Specifically manufactured from coconut shells
• Long life expectancy and removal efficiency
• Excellent hardness
• High surface area and micropore structure
• Less carbon changeouts, less dust and fines
• High adsorption capacity, lower pre-soak times, readily wettable
• Packaged in bags, totes, and super sacs
Applications
• Chemical process applications
• VOC control from air strippers, soil vapor extraction and air sparge systems
• Control of tank vent emissions
• HVAC
• Odor control
• Solvent recovery of low boiling point solvents
• Use as a catalyst/catalyst support
UltraSorberTM AMMO-CarbTM
UltraSorberTM AMMO-CarbTM is coal based activated carbon in pelletized or extruded form. The amount of phosphoric impregnation shall be no less than 7% by weight on the media. UltraSorberTM AMMO-CarbTM is designed for vapor phase applications.
UltraSorberTM KOH-CarbTM
Features
• High quality carbon
• Extraordinary surface area
• Fine pore structure
• High density
• Superior hardness
• Sold in bags, drums, and super sacs
Applications
• Paper industry
• Food industry
• Biogas industry
• Process and wastewater treatment industry
Contaminants Removed
• Ammonia
• Urea
The UltrasorberTM KOH-CarbTM is highly active coal based pelletized carbon impregnated with potassium hydroxide. The coal based activated carbon is manufactured for vapor phase applications.
Features
• Hydrogen sulfide removal capacity of 0.10 g/cc
• Impregnated with potassium hydroxide to target acidic gases
• Carbon tetrachloride activity of no less than 60%
• Sold in bags, drums, and super sacs
Applications
• Chemical processing
• Air stripper off-gas VOC removal
• Tank or sump air vents
• General HVAC units
• API separator vents
Contaminants Removed
• Hydrogen Sulfide
• Sulfur Dioxide
• Nitrogen Oxide
UltraSorberTM VPP-CarbTM
The UltraSorberTM VPP-CarbTM uses reactive chemistry to oxidize various pollutants. The UltrasorberTM VPP-Carb is zeolite impregnated with 6% potassium permanganate (KMnO4). Its’ high impregnated level of KMnO4 and insignificant dusting attributes make it an ideal media for gas phase filtration. The media is loaded in tanks, exhaust systems, soil vapor extraction (SVE) systems, air filtration trays and modules.
Features
• Sold in bags, drums, and super sacs
Applications
• Fresh fruit and vegetable transportation
• Refineries
• Pulp and paper mills
• Ground water remediation
• Wastewater treatment
Contaminants Removed
• Dichloroethylene (DCE)
• Trichloroethylene (TCE)
• Hydrogen Sulfide
• Mercaptans
• Acid gases
• Vinyl Chloride
• Common odors
• Aldehydes
• Ethylene
• Amines
• Chlorinated solvents
UltraSorberTM
The UltraSorberTM MER-CarbTM is highly active sulfurized granular activated carbon (GAC) manufactured via high temperature steam activation from selected grades of coconut shell. The MerCarbTM is used in vapor phase applications.
UltraSorberTM
Features
• Impregnated with 10% sulfur content by weight
• Can be loaded in tanks, exhaust systems, general HVAC systems, deep bed scrubbers, etc.
• Sold in bags, drums, and super sacs
Applications
• Manufacturing facilities
• Semiconductor facilities
• Refineries
Contaminants Removed
• Mercury
The UltraSorberTM Voc-CarbTM is a blend of UltraSorber-BCTM & VPP-CarbTM and is commonly used to remove volatile organic compounds (VOC) from vapor/gas phase. The two products blended together casts a wide net to remove a handful of inorganic and organic compounds.
Features
• (GAC) manufactured via high temperature steam activation from selected grades of coconut shell
• VPP-CarbTM its high impregnated level of potassium permanganate and insignificant dusting attributes make it an ideal media
• Potassium permanganate impregnated, 6 % wt. min.
• Sold in bags, drums, and super sacs
Applications
• Air dryers
• Scrubber tanks
• Exhaust systems
• Airports computer rooms
• Trays, modules, air filtration housings
• HVAC
Contaminants Removed
• BTEX
• Acid gases
• Chlorinated solvent
• Diesel fume
• Asphalt fume
• Butadiene
• Smoke
The UltraSorberTM CannaSorbTM is a proprietary blend of selective media for odor and volatile organic compounds (VOC) removal. This media is successful at removing terpenoids and terpenes from vapor phase. Terpenoids and terpenes are large organic compounds produced by cannabis plants. The UltraSorberTM CannaSorbTM is commonly found in the final product handling rooms such as the curing/drying, cutting/deflowering, extraction, and packaging rooms. At the final product handling rooms the odors described as floral, fruity, pungent, or even skunky are strongest.
Features
• Does not promote bacterial or mold growth
• Designed specifically for cannabis grow houses, but can be used in indoor cultivation facilities.
• Sold one cubic foot boxes (33 lbs/box), drums, or supersacks
Applications
• Curing/drying rooms
• Cutting/deflowering rooms
• Extraction and packaging rooms
Contaminants Removed
• Terpenoids
• Terpenes
• Limonene
• Pinene
• Fertilizer VOC
UltraVentTM Air Filter
Reversible Activated Carbon Filter
Differential static pressure across filters will cause differential contaminent accumulation in the media. UltraventTM reversible carbon filter is the only filter to offer a solution with the twist lock flange and end cap allowing to reverse the filter and equalize contaminent distribution in the media.
Most cylindrical-type air filters utilize 65% of the carbon available by only filtering through the top section of the carbon filter, leaving the bottom section unused. UltraventTM’s innovative patented design allows reversal of the filter, benefitting of 100% of the carbon available and extending the units' life span. Manufactured with only the finest high porosity activated carbon, UltraventTM effectively removes 99.5% of odors. Rated for a continuous worry-free operation and available in many different sizes and CFM ratings, UltraventTM filter can be used for industrial, commercial or residential applications.
Features
• Rubber gasket to ensure air tight fitting
• Twist lock Flange. No tools required
• Parts made of high impact resistant polycarbonate
• High quality galvanized steel
• High capacity prefilter:
- 20mm thickness
- Low air resistance
- Antibacterial
- High capacity: 670g /m2
- Flame retardant
• High porosity virgin extruded activated carbon 4mm. Specially designed to remove VOC. 66mm bed thickness
• Convenient elastic band easing installation of the prefilter
• Twist lock end cap. No tools required
UltraSorber-Air™-500
Features
• Maximum Flow: 500 cfm
• Carbon Weight: 2000 lbs
• System Pressure Drop: 19" wc
• Dimensions: 88" H x 46" W
• Capacity: 500 Gallons
• Weight: 650 lbs (Tank) + Media
Applications
• Emissions from industrial plants
• Refinery and chemical plant wastewater
• Soil vapor extraction
• BioVenting
• Emissions from waste processing operations
• Air stripper off-gas VOC removal
• API separator vents
• Waste water and product storage tank vents
• Emergency air quality control
• ACI systems for mercury reduction
• Lift stations
• Industrial odor
• Air treatment
Contaminants Removed
• VOC
• Hydrogen sulfide
• Sulfur dioxide
• Formaldehyde
• Ethylene
• Mercaptans
• Various aldehydes
• Alcohols
• Carbon dioxide
• Nitrogen
• Mercury
• Solvents
UltraVentTM-OD
VOC & Odour Control Ventilator System
UltraVent™ is an effective and easily transportable air purification system for quick response specifically designed to treat toxic vapors, irritant and corrosive gases and other noxious odors in emergency, temporary or fixed situations which uses granular activated carbon to remove organic contaminants from an air stream. UltraVent™ system is easily portable and can be delivered and installed in hours at your facility or site.
Includes
• Metal drum with carbon
• Top mounted blower
• Start Switch with Internal thermal overload protection
• 15 Feet of SOW cable and standard plug
• Dolly with casters for ease of transportation
*Tubing not included
UltraSorberTM-Air Treatment Units
What Is Your Contaminant?
ERE manufactures the UltraSorberTM Air treatment units for many different types of applications. From industrial to commercial applications. Also available in different sizes. Each unit is specifically designed for each application.
UltraSorber-AmmoTM, Ammonia Removal
Media: Anthracite Coal impreg. Phosphoric Acid
UltraSorber-CHLOROTM, Chlorine & Acidic Gas Removal
Media: Zeolite Impreg. with Potassium Permanganate Mixed with Coconut Shell
90-024-55M
When considering activated carbon for air filtration, several factors needs to be taken into account:
• Adsorbate type and concentration
• Oxidation/reaction potential for adsorbed compounds (most commonly associated with ketones)
• Air temperature
•
REPAIR AND CALIBRATION SERVICES
ERE is the Ultimate source in Environmental Equipment. This reputation also demands ultimate service for the equipment. You can rely on ERE’s service department for timely repair and/or calibration of instruments and equipment.
Whether it’s a routine calibration, maintenance or repair, come and join us! The coffee is on us!