Assembly instructions MAIOR VISION BALUSTRADE
THE VIDEO OF THE ASSEMBLY (Faraone YouTube channel)
ARCHITETTURE TRASPARENTI
ARCHITETTURE TRASPARENTI
How to mount the MAIOR VISION system
A
MAIOR VISION, with ground fastening featuring external glass, can be used outdoor and indoor.
1 L= resistance to thrust up to 200 Kg/m
INTERNAL L EXTERNAL
L
Drill the ø10 mm holes in the floor according to the instructions. Position the posts every 1,500 mm maximum. Resistance to thrust up to 300 kg/m, position the posts every 1,000 mm maximum.
min. 50mm
B
B
A
2
B
B A
B
B A
B
B
A
B A
A
A
B A
A
B
HOLE a
HOLE b
Art. MR-01-V1B
Art. MR-13/AC/11 MR-01/V5
B A
INTERNAL B
A
A
B A
A
B
B A
B
EXTERNAL
B A
A
A
Insert the relative dowels in the holes.
3
INTERNAL MR-01/G
Guarnizione anti-infiltrazione
MR-01/G anti-infiltration gasket
EXTERNAL
Position the posts vertically by intervening on the adjusters and aiding with a level. MR-01/G
Guarnizione anti-infiltrazione
How to mount the MAIOR VISION system
4 MR-13
INTERNAL EXTERNAL
5
Assemble art. Mr-013, complete with spacers.
CHIUSURA DELLA PINZA SUPERIORE DALL' INTERNO
INTERNAL
EXTERNAL
Place the glass on the lower clamp and insert it also in the upper clamp.
CHIUSURA DELLA PINZA SUPERIORE DALL' INTERNO
6
CHIUSURA DELLA PINZA SUPERIORE DALL' INTERNO
INTERNAL
Closure of the upper clamp from the inside.
EXTERNAL
Assemble and close also the other side of the clamp and finally tighten the mr-13 clamps.
7 INTERNAL
EXTERNAL
Proceed with the fixing of the handrail and the relative caps.
ARCHITETTURE TRASPARENTI
ARCHITETTURE TRASPARENTI
How to mount the MAIOR VISION system
B
MAIOR VISION with fascia mounting featuring full-height external glass, can be used outdoor.
1 L= resistance to thrust up to 200 Kg/m
INTERNAL
L EXTERNAL L
min. 50mm
A
A
Drill the holes in the floor according to the instructions. Upper hole ø16 mm, lower hole ø10 mm. Position the posts every 1,500 mm maximum. Resistance to thrust up to 300 kg/m, position the posts every 1,000 mm maximum.
B B
2
A
A
B B
A
A
A
A B
B
INTERNAL A
A
A
A B
B
B
A
A
B
A
B
Art. MR-01/V1
B
B B
A
HOLE b
Art. MR-01/v3 MR-01/V4
B
B
A
HOLE a
EXTERNAL
A B
B
Insert the relative dowels in the holes.
3
FLOOR screed
Art. MR-01/V3 MR-01/V4
INTERNAL
Art. MR-01/V1
min. 50mm
CONCRET
EXTERNAL Position the pre-assembled posts in correspondence with the holes, fix them to the floor with the appropriate screws.
How to mount the MAIOR VISION system
4 INTERNAL
EXTERNAL
Assemble art. Mr-013, complete with spacers.
5 INTERNAL
EXTERNAL
Place the glass on the lower clamp and insert it also in the upper clamp.
6 INTERNAL
Temporary closure of the clamp only to support the glass before assembly.
7
EXTERNAL
Assemble and close also the other side of the clamp and finally tighten the mr-13 clamps.
INTERNAL
EXTERNAL
Proceed with the fixing of the handrail and the relative caps.
ARCHITETTURE TRASPARENTI
ARCHITETTURE TRASPARENTI
How to mount the MAIOR VISION system
C 1
MAIOR VISION with fascia mounting featuring internal glass, ideal for indoor and outdoor elevated walkways.
INTERNAL Drill the holes in the floor according to the instructions. Upper hole ø16 mm, lower hole ø10 mm. Position the posts every 1,500 mm maximum. Resistance to thrust up to 300 kg/m, position the posts every 1,000 mm maximum.
L
L= resistance to thrust up to 200 Kg/m
EXTERNAL
L
min. 50mm
A
2
B B
A
A
INTERNAL
B
A
A
B B
B
A
B
A
A B
B
A
A
A
A
A
3
A
A
B B
B
A B
HOLE a
HOLE b
Art. MR-01/v3 MR-01/V4
Art. MR-01/V1
B
EXTERNAL
A
Insert the relative dowels in the holes.
B B
A
FLOOR
B B
screed
Art. MR-01/V3 MR-01/V4 Art. MR-01/V1
EXTERNAL
min. 50mm
CONCRET
INTERNAL
Position the pre-assembled posts in correspondence with the holes, fix them to the floor with the appropriate screws.
4 INTERNAL
EXTERNAL Position the posts vertically by intervening on the adjusters and aiding with a level.
How to mount the MAIOR VISION system
5 EXTERNAL
INTERNAL
Loose art. mr-08, insert the lower profile mr04 complete with lower gasket.
6 EXTERNAL
INTERNAL Insert the glass in the lower profile, lay it on the delrin dowels (not supplied).
7 EXTERNAL
INTERNAL
Assemble and close also the other side of the clamp.
8 EXTERNAL
INTERNAL Proceed with the fixing of the handrail and the relative caps.
ARCHITETTURE TRASPARENTI
ARCHITETTURE TRASPARENTI
How to mount the MAIOR VISION system
D
MAIOR VISION with fascia mounting featuring internal glass, ideal to ensure a relevant safety for children when mounted on a stair. Can be used indoor and outdoor. Foro inferiore
1
Foro inferiore
61
L= resistance to thrust up to 200 Kg/m
INTERNAL
61
mm
L EXTERNAL
L
min. 50mm
A B
2
A
A
B
A
A
A
A
B
B
INTERNAL A
A
A
A
Drill the holes in the floor according to the instructions. Upper hole ø16 mm, lower hole ø10 mm. Position the posts every 1,500 mm maximum. Resistance to thrust up to 300 kg/m, position the posts every 1,000 mm maximum.
HOLE a
HOLE b
Art. MR-01/v3 MR-01/V4
Art MR-01/V2
A
B
B
A
A
A
A
B
EXTERNAL
B
A
A
B
Insert the relative dowels in the holes.
3 INTERNAL
FLOOR CONCRET Art. MR-01/V3 MR-01/V4
min. 50mm
Art. MR-01/V2
EXTERNAL Position the pre-assembled posts in correspondence with the holes, fix them to the floor with the appropriate screws.
How to mount the MAIOR VISION system
4 INTERNAL
EXTERNAL
Place the glass on the lower clamp and insert it also in the upper clamp.
5 INTERNAL
Temporary closure of the clamp only to support the glass before assembly.
EXTERNAL
Assemble and close also the other side of the clamp and finally tighten the mr-13 clamps.
6 INTERNAL
EXTERNAL
Proceed with the fixing of the handrail and the relative caps.
ARCHITETTURE TRASPARENTI
FARAONE SRL ARCHITETTURE TRASPARENTI SEDE via Po 12 - 64018 Tortoreto Lido (TE) T 0861 784200 F 0861 781035 @ faraone@araone.it WEB www.faraone.it