Sub-Octa Abutment System Sub Octa Abutment
Octa Healing Cap
Abutment Diameter
Cuff
Code No.
Ø4.8
1mm 1.5mm 2.5mm 3.5mm 4.5mm 5.5mm
DSOA480 DSOA481 DSOA482 DSOA483 DSOA484 DSOA485
Abutment Diameter
Code No. DIOHC
Ø4.8
Impression Coping
Part
Abutment Diameter
Type
Ø4.8
Pick-Up
Code No. DIOIO DIOIN
Transfer
DIOTI
Pick-Up
Transfer
Ⅳ. Components of Dentis Products |
59
1
Lab Analog
Abutment Diameter
Code No. DIOLA
Ø4.8
Gold Cylinder
Octa
N-Octa
60
Abutment Diameter
Type
Code No.
Ø4.8
Octa N-Octa
DIOGCO DIOGCN
Sub-Octa Abutment System Plastic Cylinder
Abutment Diameter
Type
Code No.
Ø4.8
Octa N-Octa
DIOPO DIOPN
Part Octa
N-Octa
Ⅳ. Components of Dentis Products |
61
1
4) O-Ring Abutment System
O-Ring
O-Ring Retainer
O-Ring Lab Analog
O-Ring Abutment Driver
O-Ring Abutment
Healing Abutment
Cover Screw
Submerged Fixture
62
1.25 Hex Driver
O-Ring Abutment System O-Ring Abutment
Abutment Diameter
Cuff
Code No.
Ø3.4 Ø4.5 Ø4.5
0.5mm 2mm 4mm
DSORA00 DSORA20 DSORA40
Cuff: 0.5, 2, 4mm
Part
O-Ring Lab Analog
Code No. DOLA
O-Ring Retainer
Code No. DOR
O-Ring
Code No. ORING
Ⅳ. Components of Dentis Products |
63
1
3. Dentis External Implant System Flow External Fixture
Fixture Mount can be used for Imperssion Coping and Free Abutment. Fixture mount is economical and makes it simple for dental prosthetics. Mount could be used as transfer type of impression coping and final abutment after inserted fixture. Tapered design Root Form Design achieved superb initial fixation strength also in places where condition of the bone is not good, makes an easy and stable surgery possible and reduces surgery time. Micro-Thread for Bone Loss Prevention It prevents water absorption of the cortex due to bacterial infection and minimizes bone loss, breaking due to internal stress and stimulus of the cortical bone with stable initial fixation strength and wedges in thin cortex as well.
Ă— 50
Safe cutting edge It minimizes resistance of the bone during insertion of the implant and functions to provide safe and smooth insertion.
RBM Surface Treatment (1.5-1.8um) It maximizes osseointegration.
Ă— 5,000
64
External Implant System Products ø2.4
Part ø3.5 0.7㎜
Mini L
Implant Diameter
ø3.5
ø2.8
Platform Diameter
ø3.5
Length
Code
8.0mm
DEFM3508
10.0mm
DEFM3510
12.0mm
DEFM3512
14.0mm
DEFM3514
ø2.7
ø4.1 0.7㎜
Regular Implant Diameter
L
ø4.1
Platform Diameter
ø4.1
ø3.4
Length
Code
8.0mm
DEFR4108
10.0mm
DEFR4110
12.0mm
DEFR4112
14.0mm
DEFR4114
ø3.4
ø5.1 0.7㎜
Wide L
ø4.4
Implant Diameter
ø5.1
Platform Diameter
ø5.1
Length
Code
8.0mm
DEFW5108
10.0mm
DEFW5110
12.0mm
DEFW5112
14.0mm
DEFW5114
Ⅳ. Components of Dentis Products |
65
1
Prosthetic Flow Diagrams for External Type Implant 1) Cemented Abutment System
Hex
N-Hex
15째
Cemented Abut.
25째
Hex
Angled Abut.
N-Hex
Gold UCLA
Hex
N-Hex
Plastic UCLA
Lab Analog
Hex
Impression Coping(Pick-up)
Healing Abutment
Cover Screw
Mount
External Fixture
66
N-Hex
Impression Coping(Transfer)
1.2 Hex Driver
Cemented Abutment System Mount
Platform Diameter
Code No.
Mini
DEFMM
Regular
DEFMR
Wide
DEFMW
Part
Short Mount
Platform Diameter
Code No.
Mini
DEFMSM
Regular
DEFMSR
Wide
DEFMSW
Platform Diameter
Code No.
Mini
DECSM
Regular
DECSR
Wide
DECSW
6.5mm
Cover Screw
Healing Abutment
Platform Diameter
Cuff
Code No.
Mini
2mm 3mm 4mm 5.5mm 7mm
DEHM420 DEHM430 DEHM440 DEHM455 DEHM470
2mm 3mm 4mm 5.5mm 7mm
DEHR520 DEHR530 DEHR540 DEHR555 DEHR570
2mm 3mm 4mm 5.5mm 7mm
DEHR620 DEHR630 DEHR640 DEHR655 DEHR670
2mm 3mm 4mm 5.5mm 7mm
DEHW620 DEHW630 DEHW640 DEHW655 DEHW670
Cuff: 2, 3, 4, 5.5, 7mm
Regular
Wide
Ⅳ. Components of Dentis Products |
67
1
Impression Coping
Platform Diameter Pick-Up
Impression Coping
Code No. Hex N-Hex
DEIM40H DEIM40N
Regular
Hex N-Hex Hex N-Hex
DEIR50H DEIR50N DEIR60H DEIR60N
Wide
Hex N-Hex
DEIW60H DEIW60N
Mini
Pick-Up
Type
Type
Platform Diameter Transfer
Code No. Hex N-Hex
DETIM40H DETIM40N
Regular
Hex N-Hex Hex N-Hex
DETIR50H DETIR50N DETIR60H DETIR60N
Wide
Hex N-Hex
DETIW60H DETIW60N
Mini
Hex
N-Hex
Transfer Lab Analog
Cemented Abutment
Platform Diameter
Hex
Cuff: 1, 2, 3, 4mm N-Hex
68
Mini
DELAM
Regular
DELAR
Wide
DELAW
Type Cuff Length
Code No. Mini DECAM416H DECAM426H DECAM436H DECAM446H
Regular DECAR516H DECAR616H DECAR526H DECAR626H DECAR536H DECAR636H DECAR546H DECAR646H
Wide DECAW616H DECAW626H DECAW636H DECAW646H
8mm
DECAM418H DECAM428H DECAM438H DECAM448H
DECAR518H DECAR528H DECAR538H DECAR548H
DECAR618H DECAR628H DECAR638H DECAR648H
DECAW618H DECAW628H DECAW638H DECAW648H
N-Hex 1mm 2mm 3mm 4mm
6mm
DECAM416N DECAM426N DECAM436N DECAM446N
DECAR516N DECAR526N DECAR536N DECAR546N
DECAR616N DECAR626N DECAR636N DECAR646N
DECAW616N DECAW626N DECAW636N DECAW646N
1mm 2mm 3mm 4mm
8mm
DECAM418N DECAM428N DECAM438N DECAM448N
DECAR518N DECAR528N DECAR538N DECAR548N
DECAR618N DECAR628N DECAR638N DECAR648N
DECAW618N DECAW628N DECAW638N DECAW648N
Hex L
Code No.
1mm 2mm 3mm 4mm
6mm
1mm 2mm 3mm 4mm
Cemented Abutment System Angled Abutment
Cuff: 2, 4mm 15°
Type
Cuff
Length
15°
2mm 4mm
8mm
25°
2mm 4mm
8mm
Platform Diameter Mini DEAAM4215 DEAAM4415
Regular DEAAR5215 DEAAR6215 DEAAR5415 DEAAR6415
Wide DEAAW6215 DEAAW6415
DEAAM4225 DEAAM4425
DEAAR5225 DEAAR6225 DEAAR5425 DEAAR6425
DEAAW6225 DEAAW6425
Part
25°
Gold UCLA
Type
Platform Diameter
Hex
Mini DEGUMH
Regular DEGURH
Wide DEGUWH
N-Hex
DEGUMN
DEGURN
DEGUWN
Hex
N-Hex
Plastic UCLA
Type
Platform Diameter
Hex
Mini DEPMH
Regular DEPRH
Wide DEPWH
N-Hex
DEPMN
DEPRN
DEPWN
Hex
N-Hex
Ⅳ. Components of Dentis Products |
69
1
2) Estheticone Abutment System
Hex
N-Hex
Hex
Gold Cylinder
N-Hex
Plastic Cylinder
Lab Analog
Impression Coping(Transfer)
Impression Coping(Pick-up)
Estheticone Driver
Estheticone Abut.
Healing Cap
Cover Screw
Healing Abutment
Mount
External Fixture
70
1.2 Hex Driver
Estheticone Abutment System Estheticone Abutment
Platform Diameter
Cuff
Code No.
Ø4.1
1mm 2mm 3mm 4mm
DEEA10 DEEA20 DEEA30 DEEA40
Ø5.1
1mm 2mm 3mm 4mm
DEWA10 DEWA20 DEWA30 DEWA40
Cuff:1, 2, 3, 4mm
Healing Cap
Impression Coping
Platform Diameter
Code No.
Ø4.1
DEEHC
Ø5.1
DEWHC
Platform Diameter Ø4.1 Ø5.1
Part
Type Pick-Up
Code No.
Hex N-Hex
DEESIH DEESIN
Hex N-Hex
DEWSIH DEWSIN
Pick-Up
Impression Coping
Platform Diameter
Type
Ø4.1
Transfer
Ø5.1
Code No. DEETI DEWTI
Transfer
Ⅳ. Components of Dentis Products |
71
1
Lab Analog
Gold Cylinder
Hex
N-Hex
72
Platform Diameter
Code No.
Ø4.1
DEELA
Ø5.1
DEWLA
Platform Diameter
Type
Code No.
Ø4.1
Hex N-Hex
DEEGCH DEEGCN
Ø5.1
Hex N-Hex
DEWGCH DEWGCN
Estheticone Abutment System Plastic Cylinder
Platform Diameter
Type
Code No.
Ø4.1
Hex N-Hex
DEMPH DEMPN
Ø5.1
Hex N-Hex
DEWPH DEWPN
Part
Hex
N-Hex
Ⅳ. Components of Dentis Products |
73
1
3) O-Ring Abutment System
O-Ring
O-Ring Retainer
O-Ring Lab Analog
O-Ring Abutment Driver
O-Ring Abutment
Healing Abutment
Cover Screw
Mount
External Fixture
74
1.2 Hex Driver
O-Ring Abutment System O-Ring Abutment
Cuff:2, 4mm
Abutment Diameter
Cuff
Code No.
Ø4.1
2mm 4mm
DEORRA20 DEORRA40
Ø5.1
2mm 4mm
DEORWA20 DEORWA40
Part
O-Ring Lab Analog
Code No. DOLA
O-Ring Retainer
Code No. DOR
O-Ring
Code No. ORING
Ⅳ. Components of Dentis Products |
75
1
4. Dentis SAVE Submerged Implant System Flow SAVE Submerged Fixture
“Convenient”No Mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however Dentis Nomount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth. Convenient Compatibility of Superstructure It is economical to use with Dentis’superstructure so there is no need for additional SAVE Abutment System. Platform Switching System Further loss of the alveolar bone is not allowed. It reduces alveolar bone loss to the maximum in the Fixture Should region using Platform Switching Process. Micro-thread for Bone Loss Prevention Dentis Implant Micro-thread minimizes bone loss, breaking due to internal stress and appropriate stimulus of the cortical bone together with stable initial fixation. Optimum RBM Surface Treatment Roughness measurement of the surface is Ra: 1.5-1.8um. This measurement is the most ideal value for osseointegration.
× 5,000
Safe Cutting Edge / Taper Design It has been designed for excellent osseointegration as well as excellent initial fixation as it remarkably reduces excessive friction with the bone due to uniform transmission of strength during insertion.
76
SAVE Submerged Implant System Products
Part
ø5.5 SAVE Submerged Fixture Size ø5.5 0.4㎜
ø5.5 0.4㎜
7.0㎜
8.0㎜
ø4.8
ø5.5
ø5.5
0.4㎜
0.4㎜
10.0㎜
12.0㎜
ø4.8 ø4.8 ø4.8
Code Length
DSFS5507 7mm
Code Length
DSFS5508 8mm
Code Length
DSFS5510 10mm
Code Length
DSFS5512 12mm
ø6.0 SAVE Submerged Fixture Size ø6.0 0.4㎜
0.4㎜
0.4㎜
7.0㎜
8.0㎜
ø5.3
ø6.0
ø6.0
ø6.0
0.4㎜
10.0㎜
12.0㎜
ø5.3 ø5.3 ø5.3
Code Length
DSFS6007 7mm
Code Length
DSFS6008 8mm
Code Length
DSFS6010 10mm
Code Length
DSFS6012 12mm
Ⅳ. Components of Dentis Products |
77
1
5. Dentis SAVE Internal Implant System Flow SAVE Internal Fixture
“Convenient”No Mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however Dentis Nomount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.
Micro-thread for Bone Loss Prevention Dentis Implant Micro-thread minimizes bone loss, breaking due to internal stress and appropriate stimulus of the cortical bone together with stable initial fixation.
Optimum RBM Surface Treatment Roughness measurement of the surface is Ra: 1.5~1.8um. This measurement is the most ideal value for osseointegration.
× 50
× 5,000
Safe Cutting Edge / Taper Design It has been designed for excellent osseointegration as well as excellent initial fixation as it remarkably reduces excessive friction with the bone due to uniform transmission of strength during insertion.
78
SAVE Internal Implant System Products
Part
ø5.5 SAVE Internal Fixture Size ø6.0 0.65㎜
ø6.0 0.65㎜
2.0㎜
2.0㎜
7.0㎜
8.0㎜
ø6.0
ø6.0 0.65㎜
0.65㎜
2.0㎜
2.0㎜
10.0㎜
12.0㎜
ø4.8 ø4.8
ø5.5
ø4.8
ø5.5
ø4.8 ø5.5
ø5.5
Code Length
DIFS5507 7mm
Code Length
DIFS5508 8mm
Code Length
DIFS5510 10mm
Code Length
DIFS5512 12mm
ø6.0 SAVE Internal Fixture Size ø6.0
ø6.0
0.65㎜ 2.0㎜
0.65㎜ 2.0㎜
7.0㎜
8.0㎜
ø6.0
ø6.0
0.65㎜ 2.0㎜
0.65㎜ 2.0㎜
10.0㎜
12.0㎜
ø5.3 ø5.3 ø5.3 ø5.3
Code Length
DIFS6007 7mm
Code Length
DIFS6008 8mm
Code Length
DIFS6010 10mm
Code Length
DIFS6012 12mm
Ⅳ. Components of Dentis Products |
79
1
Cover Screw
Platform Diameter
Cuff
Code No.
Ø6.0(SAVE only)
2mm
DISCS60
Platform Diameter
Cuff
Code No.
Ø6.0(SAVE only)
3mm 4mm 5.5mm
Platform Diameter
Type
Ø6.0(SAVE only)
Pick-Up
2mm
Healing Abutment
DIHS30 DIHS40 DIHS55
Cuff:3, 4, 5.5mm
Impression Coping
Pick-Up
80
Code No. DIPIS60
InOcta Abutment System Lab Analog
Platform Diameter
Code No.
Ø6.0(SAVE only)
DILAS
Part
InOcta Abutment
Platform Diameter
Type
Cuff
Code No.
Ø6.0(SAVE only)
Octa
1mm 2mm 3mm 4mm
DICOS10 DICOS20 DICOS30 DICOS40
N-Octa
1mm 2mm 3mm 4mm
DICOS10N DICOS20N DICOS30N DICOS40N
6mm
Octa
Cuff:1, 2, 3, 4mm N-Octa
Ⅳ. Components of Dentis Products |
81
1
Dentis Surgical Kit Part
â…¤
1. Characteristics of Surgical Tool 2. Combined KIT 3. SAVE KIT 4. PRO KIT
1
Ⅴ. Dentis Surgical Kit 1. Characteristics of Surgical Tool 1) DENTIS Multi Surgical Kit
SAVE KIT
Combined KIT
PRO KIT
2) Stopper drill
ø2.2 12mm Twist Drill
ø2.8 12mm Twist Drill
ø3.5 12mm Twist Drill
ø3.7 12mm Twist Drill
ø4.1 12mm Twist Drill
ø4.3 12mm Twist Drill
ø4.8 12mm Twist Drill
ø5.1 12mm Twist Drill
The Special Features of Safe Stopper Twist Drill 1. SAFE DRILL STOPPER The Stopper of 3-Blade Safe Tapered Twist Drill is used to prevent nerves injury from excessive drilling. 2. 3-BLADE SAFE TWIST DRILL 3-blade Safe Tapered Twist drill, produced only by DENTIS Company, has excellent cutting capability to prevent bone heating and drilling can operated at a low speed. It could easily extract bone chips and is stable for surgical operation. 3. TAPER 3-blade Safe Tapered Twist Drill, produced only by DENTIS Company, can be used at a low drilling speed to taper into the bone and gives accurate surgical operation.
3) Multi stopper drill - Stopper Basically 2mm Rotary Stopper is fitted. Attaching and detaching is smooth and easy. When stopper makes contact with the bone, it stops rotating, hence does not damage the bone. 2㎜
3㎜
4㎜
-Drill short
Long
ø5.5-S Drill
8㎜ 7㎜ 6㎜
2㎜ stopper
3㎜ stopper
8㎜ 7㎜ 6㎜
7㎜
4㎜ stopper
6㎜
ø5.5-L Drill
12㎜ 10㎜
2㎜ stopper
4㎜ stopper
12㎜ 10㎜
Basically Rotating Stopper is fitted. Short drill is 10mm and Long drill is 14mm. If a 4-mm stopper is fitted, the short drill can be adjusted to 8mm and the long drill to 12mm. It is convenient and possible to use without the stopper depending on the shape of the bone during surgery.
84
10㎜
4) Excellent Enhancement of W/C Coating Treatment Tungsten Carbide Coating is 4 times stronger and easier to drill than other drills and Part
minimizes bone heating during drilling.
5‘C ) onvenient’Depth Gauge It is easy to check the space between fixtures and the depth of Mesiodistal and the location of buccolongual during initial drilling.
6‘C ) onvenient’No-Mount Driver Dentis No-mount Driver can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.
7) Multiple Tap Drill It is manufactured for Machine and Hand use, using an adaptor that can be attached to 3 kinds of drivers(Rachet Long, Rachet Short for Machine use and Ratchet for Hand use)
8) Torque Rachet Convenient fittings and accurate torque value are measured in units 15NCm, 25NCm, and 35NCm. It is be managed efficiently by simply disassembling it and can be easily cleaned inside after operation.
Ⅴ. Dentis Surgical Kit |
85
1
Combined KIT Internal / Submerged Kit External Kit
86
Internal/Submerged Fixture Dentis Internal Fixture Surgical Drilling Sequence Insertion Method Depending on the Bone Condition (Drilling Sequence) Part Ø3.7 Fixture Criterion D4 Bone
point drill →2.2drill →2.8drill →3.7 Fixture
D2-3 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill →Ø3.7 Fixture
D1 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill →3.7 Tap drill →Ø3.7 Fixture
Ø4.3 Fixture Criterion D4 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill→Ø4.3 Fixture
D2-3 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →Ø4.3 Fixture
D1 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →4.3 Tap drill →Ø4.3 Fixture
Ø4.8 Fixture Criterion D4 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →Ø4.8 Fixture
D2-3 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →4.8 Fixture drill →Ø4.8 Fixture
D1 Bone
point drill →2.2drill →2.8drill →3.7 Fixture drill→4.3 Fixture drill →4.8 Fixture drill →4.8 Tap drill →Ø4.8 Fixture
External Fixture Dentis Internal Fixture Surgical Drilling Sequence Insertion Method Depending on the Bone Condition (Drilling Sequence) Ø3.5 Fixture Criterion D4 Bone
point drill →2.2drill →2.8drill →Ø3.5 Fixture
D2-3 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →Ø3.5 Fixture
D1 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →3.5 Tap drill →Ø3.5 Fixture
Ø4.1 Fixture Criterion D4 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →Ø4.1 Fixture
D2-3 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →Ø4.1 Fixture
D1 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →4.1 Tap drill →Ø4.1 Fixture
Ø5.1 Fixture Criterion D4 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →Ø5.1 Fixture
D2-3 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →5.1 Fixture drill →Ø5.1 Fixture
D1 Bone
point drill →2.2drill →2.8drill →3.5 Fixture drill →4.1 Fixture drill →5.1 Fixture drill →5.1 Tap drill →Ø5.1 Fixture
Ⅴ. Dentis Surgical Kit |
87
1
KIT 5.5, 6.0 Fixture [Exclusive use] Surgical Kit Internal / Submerged [Multiple Use] Stopper Drill
Drill Basically Rotating Stopper is fitted. Short drill is 8 mm and Long drill is 12mm. If a 4-mm stopper is fitted, the short drill can be adjusted to 6mm and the long drill to 10mm. It is convenient and possible to use without the stopper depending on the shape of the bone during surgery. Stopper Basically 2mm Rotary Stopper is fitted. Attaching and detaching is smooth and easy. When stopper makes contact with the bone, it stops rotating, hence reduce damage to the aveolar bone. No-Mount Driver No-mount Driver can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.
88
Part
The Function of Path Guide during Insertion of Many Fixtures Diagnosis of the Length and Size of Dental Prosthesis Simultaneously During Insertion
PROKIT, first in the world, developed for diagnosis or use in operation, consists of a system that can be used for getting dental impression for prosthesis during surgery, as it provides all kinds of abutments that can be used in Internal Fixture and Internal Submerged Fixture. It is easy to distinguish inside of the mouth or during operation due to color coding surface treatment according to the shape and type. It is made of titanium like the surgical superstructure which is not made of plastic. It can also be used in all kind of dental autoclave just as other operating tools.
â…¤. Dentis Surgical Kit ď˝œ
89
1
Surgical Kit and Tool Part
â…Ľ
1. Drilling Sequences : Internal and Submerged Type 2. Drilling Sequences : External Type
1
â…Ľ. Surgical Kit and Tool 1. Drilling Sequences : Internal and Submerged Type
92
Part
Ⅵ. Surgical Kit and Tool |
93
1
94
2. Drilling Sequences : External Type
Part
Ⅵ. Surgical Kit and Tool |
95
1
96
Part
Ⅵ. Surgical Kit and Tool |
97
1
Abutment Prosthetic Protocol Part
â…Ś
1. Abutment System Selection Guide 2. Impression Taking : Internal Type 3. Impression Taking : Submerged Type 4. Impression Taking : External Type
1
Ⅶ. Abutment Prosthetic Protocol 1. Abutment System Selection Guide ● Fixture
● Abutment
● Gold Cylinder
Solid 4mm
Healing Abutment
5.5mm
7mm
4mm
Solid Abutment
5.5mm
7mm
Excellent Solid Abutment
InOcta Cover Screw Free Abutment
InOcta Abut.
Angled Abutment (15°. 25°)
SynOcta Abut.
Octa
N-Octa
Gold Cylinder Octa
N-Octa
Gold UCLA
Octa Octa Abutment
Internal Fixture
Sole 4.5mm Healing Abutment
5.5mm Sole Abutment
6.5mm
Couple Cover Screw Free Abutment
Couple Abutment
Angled Abutment (15°. 25°)
Gold UCLA
Hex
N-Hex
Sub-Octa Submerged Fixture
Healing Cover Screw Abutment
Sub-Octa Abutment
Gold Cylinder Octa
N-Octa
Hex
N-Hex
Cemented Cemented Abutment
Angled Abutment (15°. 25°)
Gold UCLA
Mount
Estheticone
External Fixture
100
Estheticone Abutment
Gold Cylinder Hex
N-Hex
● Plastic Cylinde / Coping
● Impression Coping / Cap
● Lab Analog
● O-ring
Part O-Ring
Plastic Coping
Single
Bridge
Impression Cap Pick-Up
Positioning Cylinder
Shoulder Analog & Pin
Lab Analog
Retainer
Impression Coping Transfer
Octa
Lab Analog Pick-Up
Lab Analog
Impression Coping Transfer
N-Octa
Plastic Cylinder
Octa
N-Octa
Lab Analog
Abutment
O-Ring
Plastic Coping Single
Impression Cap
Bridge Pick-Up
Lab Analog
Retainer
Impression Coping Transfer
Hex
Hex
N-Hex
Pick-Up
Hex
N-Hex
Lab Analog
Lab Analog
Impression Coping Transfer
N-Hex
Plastic Cylinder
Octa
Lab Analog
N-Octa Pick-Up
Abutment
Impression Coping Transfer
O-Ring
Plastic UCLA
Hex
N-Hex
Hex
N-Hex
Hex
Pick-Up
Plastic Cylinder
Hex
N-Hex
N-Hex
Lab Analog
Retainer
Impression Coping Transfer
Lab Analog
Abutment
Lab Analog
Ⅶ. Abutment Prosthetic Protocol | 101
1
2. Impression Taking : Internal Type
Solid Abutment (indirect impression method) - Solid (indirect impression method)Abutment level impression method of Int. - Type is applicable for every case of Cemented type prosthesis as Single unit and Multi unit.
1. Removing a Cover Screw from the fixture.
6.Removing the tray (pattern).
11. Equipping a plastic coping (or Plastic coping work).
102
2.Combining a Solid abutment with fixture.
7.Equipping a Lab analog.
12. Cutting the coping for a moderate height.
3.Combining an impression cap.
8.Building the soft gingiva.
13. Wax-up.
4.Equipping a positioning cylinder.
9.Pouring stone in the pattern.
14. Final process for the Crown (or Bridge).
5.Capping the tray for impression taking.
10. Removing the pattern from the stone, and then making the complete working model.
15. Combining the Crown (or Bridge) for the complete implant system.
Solid Abutment (Direct impression method) - Abutment level impression method of Int. - Type is applicable for every case of Cemented type prosthesis as Single unit and Multi unit.
Part
1. Removing a Cover Screw from the fixture.
5. Pouring stone in the pattern.
2.Combining a Solid with implanted fixture directly.
6. Removing the pattern from the stone, and then making the complete working model.
7. Wax-up.
3.Capping the tray for direct impression.
8. Final process for the Crown (or Bridge).
4.Removing the tray (pattern).
9. Combining the Crown (or Bridge) for the complete implant system.
Excellent solid Abutment (Direct impression method) - Excellent solid required for expanding the size of abutment and crown around pre-molar and molar area's prosthesis in order to take stabilization of prosthesis.
1. Removing a Cover Screw from the fixture.
5.Pouring stone in the pattern.
2. Combining the Excellent Solid with implanted fixture directly.
6.Removing the pattern from the stone, and then making the complete working model.
7.Wax-up.
3. Capping the tray for direct impression.
8.Final process for the Crown (or Bridge).
4.Removing the tray (pattern).
9.Combining the Crown (or Bridge) for the complete implant system.
â…Ś. Abutment Prosthetic Protocol ď˝œ 103
1
Free Abutment - Free abutment may used as a standard abutment or an angled abutment through the milling work and adjustment of cuff height.
9.Removing the pattern from the stone, and then making the complete working model.
11. Wax-up.
13.Combining the Crown (or Bridge) for the complete implant system. 1. Removing a Cover Screw from the fixture.
10.Milling.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2.Equipping a Free Abutment and Guide pin.
3.Capping the open tray for making a pattern.
4.Removing the Guide pin.
5.Removing the tray (pattern).
6.Equipping the Guide pin on the same position of tray (pattern).
7.Equipping Lab analog and then building a soft gingiva.
8.Pouring stone in the pattern.
Transfer (Close Tray)
2.Equipping a Free Abutment.
104
3.Capping the tray for making a pattern.
4.Removing the tray (pattern).
5.Combining Lab analog with Free Abutment.
6.Equipping the combined Lab analog with Free Abutment in the pattern.
7.Building a soft gingiva.
8.Pouring stone in the pattern.
InOcta Abutment - The impression work for InOcta Abutment would be done in the fixture stage and it's applicable for both - Single unit case and Multi unit case. All the prosthetic working would be processed in the Lab. - Thus, it brings reduction of the chair time. It's cemented type and it's also available for SCRP type prosthetics.
Part
9. Removing the pattern from 10. Equipping Abutment the stone, and then making on the working model. the complete working model.
13. Combining the Crown (or Bridge) for the complete implant system.
1. Removing a Cover Screw from the fixture.
11. Wax-up.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2.Equipping Pick-up 3.Capping the type impression open tray for coping. making a pattern.
4.Removing the Guide pin.
5.Removing the tray (pattern).
6.Equipping the Guide pin on the same position of tray (pattern).
7. Equipping Lab analog and then building a soft gingiva.
6. Equipping Lab analog and then building a soft gingiva.
7. Pouring stone in the pattern.
8.Pouring stone in the pattern.
Transfer (Close Tray)
2. Equipping Transfer type impression coping.
3. Capping the tray for making a pattern.
4. Removing the tray (pattern).
5. Combining Lab analog with Transfer.
8. Removing the pattern from the stone, and then removing Transfer.
â…Ś. Abutment Prosthetic Protocol ď˝œ 105
1
Angled Abutment - Angled Abutment demanded for the case of bad insertion path to reward the angle, and Dentis provides, inclined Angled Abutment.
9.Combining Abutment on the working model.
10. Wax-up.
12. Combining the Crown (or Bridge) for the complete implant system. 1. Removing cover screw from the fixture.
11. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2.Equipping Pick-up type Impression coping.
3.Capping the open tray for making a pattern.
4.Removing the guide pin.
5.Removing the tray (pattern).
6.Equipping the Guide pin on the same position of tray (pattern).
7.Equipping Lab analog and then building a soft gingiva.
8.Pouring stone in the pattern.
Transfer (Close Tray)
2. Equipping Transfer type Impression coping.
106
3. Capping the tray for making a pattern.
4. Removing the tray (pattern).
5. Combining Lab analog with Transfer.
6. Equipping Lab analog and then building a soft gingiva.
7. Pouring stone in the pattern.
8. Removing the pattern from the stone, and then removing Transfer.
SynOcta Abutment - The impression work for SynOcta Abutment would be done in the fixture stage and it's applicable for both Single unit case and Multi unit case. All the prosthetic working would be processed in the Lab. - Thus, it brings reduction of the chair time. It's cemented type and it's also available for SCRP type prosthetics.
Part
9. Removing the pattern from the stone, and then making the complete working model.
10. Equipping Abutment on the working model.
13. Combining the Crown (or Bridge) for the complete implant system. 1. Removing cover screw from the fixture.
11. Wax-up.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2. Equipping Pick-up type Impression coping.
3. Capping the open tray for making a pattern.
4. Removing the guide pin.
5. Removing the tray (pattern).
6. Equipping the Guide pin on the same position of tray (pattern).
7. Equipping Lab analog and then building a soft gingiva.
8. Pouring stone in the pattern.
7. Pouring stone in the pattern.
8. Removing the pattern from the stone, and then removing Transfer.
Transfer (Close Tray)
2. Equipping Transfer type Impression coping.
3. Capping the tray for making a pattern.
4. Removing the tray (pattern).
5. Combining Lab analog with Transfer.
6. Equipping Lab analog and then building a soft gingiva.
â…Ś. Abutment Prosthetic Protocol ď˝œ 107
1
Gold UCLA Abutment - Gold UCLA Abutment is applicable for a very low occlusion case which requires esthetics and for a screw type prosthetics.
9. Removing the pattern from the stone, and then making the complete working model.
10. Equipping Gold UCLA on the working model. 13. Combining the Crown (or Bridge) for the complete implant system.
1. Removing cover screw from the fixture.
11. Wax-up.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2. Equipping Pick-up type Impression coping.
3. Capping the open tray for making a pattern.
4. Removing the guide pin.
5. Removing the tray (pattern).
6. Equipping the Guide pin on the same position of tray (pattern).
7. Equipping Lab analog and then building a soft gingiva.
8. Pouring stone in the pattern.
Transfer (Close Tray)
2. Equipping Transfer type Impression coping.
108
3. Capping the tray for making a pattern.
4. Removing the 5. Combining 6. Equipping Lab tray (pattern). Lab analog analog and then with Transfer. building a soft gingiva.
7. Pouring stone in the pattern.
8. Removing the pattern from the stone, and then removing Transfer.
Octa Abutment - It's demanded to be used in Multi case of screw type with bad implant path.
Part
10. Removing the pattern from the stone, and then making the complete working model.
1. Removing cover screw from the fixture.
11. Equipping Gold Cylinder.
14. Combining the Crown (or Bridge) for the complete implant system. 12. Wax-up.
2.Equipping Octa Abutment.
13. Final process for the Crown (or Bridge).
Pick up (Open Tray)
3.Equipping Pick-up type Impression coping.
4.Capping the tray for making a pattern.
5.Removing the guide pin.
6.Removing the tray (pattern).
7. Equipping the Guide pin on the same position of tray (pattern).
8.Equipping Lab analog and then building a soft gingiva.
9.Pouring stone in the pattern.
Transfer (Close Tray)
3. Equipping Transfer type Impression coping.
4. Capping the tray for making a pattern.
5. Removing the tray (pattern).
6. Combining Lab analog with Transfer.
7. Equipping Lab analog and then building a soft gingiva.
8. Pouring 9. Removing the stone in the pattern from the pattern. stone, and then removing Transfer.
â…Ś. Abutment Prosthetic Protocol ď˝œ 109
1
O-ring Abutment - O-ring Abutment is attachment-retained type prosthesis for the full denture case; the O-ring connected with prosthesis as the connector.
6.Pouring stone in the pattern.
1. Removing cover screw from the fixture.
7.Removing the pattern from the stone, and then making the complete working model.
2.Equipping Ball Abutment.
8.Equipping retainer on the balls.
3.Capping the tray for making a pattern. 9.Denture work.
4.Removing the tray (pattern).
10. Combining the Denture for the complete implant system. 5.Equipping Lab Analog in the position.
110
3. Impression Taking : Submerged Type
Part
Sole Abutment - Abutment level impression method of Sub - Type is applicable for every case of Cemented type prosthesis as Single unit and Multi unit.
1. Removing Healing Abutment.
5.Removing the tray (pattern).
6.Equipping Lab Analog in the position.
10. Plastic coping work.
11. Cutting the coping for a moderate height.
2.Equipping Sole Abutment.
3.Equipping Impression cap.
7.Building a soft gingiva.
12. Wax-up.
4.Capping the tray for making a pattern.
8.Pouring stone in the pattern.
13. Final process for the Crown (or Bridge).
9.Removing the pattern from the stone, and then making the complete working model.
14. Combining the Crown (or Bridge) for the complete implant system.
â…Ś. Abutment Prosthetic Protocol ď˝œ 111
1
Free Abutment - Free abutment may used as a standard abutment or an angled abutment through the milling work and adjustment of cuff height.
9.Removing the pattern from the 10. Milling. stone, and then making the complete working model.
13. Combining the Crown (or Bridge) for the complete implant system. 1. Removing Healing Abutment.
11. Wax-up.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2.Equipping a Free Abutment and Guide pin.
3.Capping the open tray for making a pattern.
4.Removing the Guide pin.
5.Removing the tray (pattern).
6.Equipping the 7. Equipping Lab Guide pin on the analog and then same position of building a soft tray (pattern). gingiva.
8.Pouring stone in the pattern.
6.Equipping the 7.Building a combined Lab analog soft gingiva. with Free Abutment in the pattern.
8.Pouring stone in the pattern.
Transfer (Close Tray)
2.Equipping a Free Abutment.
112
3.Capping the tray for making a pattern.
4.Removing the tray (pattern).
5.Combining Lab analog with Free Abutment.
Couple Abutment - The impression work for Couple Abutment would be done in the fixture stage and it's applicable for both Single unit case and Multi unit case. All the prosthetic working would be processed in the Lab. Thus, it brings reduction of the chair time. It's cemented type and it's also available for SCRP type prosthetics.
Part
9. Removing the pattern from the stone, and then making the complete working model.
10. Equipping Abutment on the working model.
13. Combining the Crown (or Bridge) for the complete implant system. 1. Removing Healing Abutment. 11. Wax-up.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2. Equipping Pick-up type Impression coping.
3. Capping the open tray for making a pattern.
4. Removing the guide pin.
5. Removing the tray (pattern).
6. Equipping the Guide pin on the same position of tray (pattern).
7. Equipping Lab analog and then building a soft gingiva.
5. Combining Lab analog with Transfer.
6. Equipping Lab analog and then building a soft gingiva.
7. Pouring stone in the pattern.
8. Pouring stone in the pattern.
Transfer (Close Tray)
2. Equipping Transfer type Impression coping.
3. Capping the tray for making a pattern.
4. Removing the tray (pattern).
8. Removing the pattern from the stone, and then removing Transfer.
â…Ś. Abutment Prosthetic Protocol ď˝œ 113
1
Gold UCLA Abutment - Gold UCLA Abutment is applicable for a very low occlusion case which requires esthetics and for a screw type prosthetics.
9. Removing the pattern from the stone, and then making the complete working model.
10. Equipping Gold UCLA on the working model.
13. Combining the Crown (or Bridge) for the complete implant system. 1. Removing Healing Abutment.
11. Wax-up.
12. Final process for the Crown (or Bridge).
Pick up (Open Tray)
2. Equipping Pick-up type Impression coping.
3. Capping the open tray for making a pattern.
4. Removing the guide pin.
5. Removing the tray (pattern).
6. Equipping the 7. Equipping Lab Guide pin on the analog in the same position of pattern and then tray (pattern). building a soft gingiva.
5. Combining Lab analog with Transfer.
6. Equipping Lab analog and then building a soft gingiva.
8. Pouring stone in the pattern.
Transfer (Close Tray)
2. Equipping 3. Capping the tray for Transfer type making a pattern. Impression coping.
114
4. Removing the tray (pattern).
7. Pouring stone in the pattern.
8. Removing the pattern from the stone, and then removing Transfer.