Ftth brochure

Page 1

258

FTTH applications

Fiber optic cables (SM / MM)

FiberConnect® Direct buried cable

HDPE outer jacket Strain relief elements Central two-layer loose tube

A-DQ(ZN)2Y 2E9/125 G657A1 5.5 Order no.

84 366012 E

Standardisation

IEC 60794-3

Description

Thermal properties

Longitudinally waterproof optical outdoor cable for direct

Transport/storage

– 25 °C to + 70 °C

burial, installation in conduits, cable ducts and/or cable trays.

Installation

– 5 °C to + 50 °C

Also suitable for vertical ladders. Machine-driven pulling in

Operating tempe-

– 25 °C to + 70 °C

with a winch only permitted with a documenting force measur-

rature

ing device. Mechanical properties Composition Cable core

outer diameter

approx. 5.5 mm

Two-layer loose tube, gel-filled, diameter

Leitungsgewicht

approx. 21.0 kg/km

2.4 mm, colour: yellow (E9/125)

Min. bending radius static

Inner layer: polycarbonate (PC)

09

dynamic

15 × outer diameter 20 × outer diameter

outer layer: polybutylene terephtalate (PBTP)

Max. pull force

600 N

colour code fibers (1–2): red, green

Max. crush resistance

5000 N/dm

Strain relief

Non-metallic (aramid)

Cable jacket

Polyethylene (HDPE)

Fire performance

Colour of jacket

O orange

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

FTTH applications

259

FiberConnect® Micro duct cable

HDPE outer jacket Central loose tube

Fiber optic cables (SM / MM)

with central multi-fiber loose tube

Strain relief elements

A-D(ZN)2Y n… MDC Order no.

84 344 Q Q Q Q

Standardisation

IEC 60794-5

Description

Mechanical properties*

Mini cable for blowing or pulling into micro ducts. The outdoor

Min. bending radius up to

static

25 mm

cable is light and flexible and can be installed with minimal

4 Fibers

dynamic

40 mm

bending radii.

up to

static

40 mm

12 Fibers

dynamic

60 mm

up to

static

60 mm

24 Fibers

dynamic

80 mm

Composition Cable core

Mini loose tube, gel-filled

Strain relief

* with bend-insensitive fibers G.657.A1; bending radii up to 15 mm

Non-metallic (aramid)

Cable jacket

HDPE with Imprint

Colour of jacket

O black

Fire performance Absence of halogen IEC 60754-1 Acidity of combus-

Thermal properties Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 25 °C to + 70 °C

tion gases

rature

Number of fibers

2 4 6 8 10 12 24

IEC 60754-2

09

Outer Ø

Weight

mm

kg/km

2.0 2.0 2.3 2.3 2.3 2.3 3.9

3.9 3.9 4.4 4.4 4.6 4.6 12.7

www.leoni-fiber-optics.com

Max. pull force

Fire load

long-term

Max. crush resistance long-term

N

N/dm

MJ/m

300 300 300 300 300 300 450

500 500 500 200 200 200 200

0.18 0.18 0.22 0.22 0.26 0.26 0.51


260

FTTH applications

FiberConnect® Mini multi-fiber loose tube

Fiber optic cables (SM / MM)

with stranded multi-fiber loose tubes

Loose tube GFR strength member HDPE outer jacket Rip cord

A-DQ2Y n… LTMC Order no.

84 345 Q Q Q Q

Standardisation

IEC 60794-5

Description

Thermal properties

Mini cable for blowing or pulling into micro ducts. The outdoor

Transport/storage

– 25 °C to + 70 °C

cable is light and flexible and can be installed with minimal

Installation

– 5 °C to + 50 °C

bending radii.

Operating tempe-

– 25 °C to + 70 °C

rature Composition Cable core

GFR strength member with stranding

Mechanical properties

elements, designed as gel-filled loose

Min. bending radius static dynamic

tubes and , if applicable, dummy elements

15 × outer diameter 20 × outer diameter

Cable jacket

HDPE with imprint

Max. pull force

500 N

Colour of jacket

O black

Max. crush resistance

500 N/dm

Resistance to impacts

3 impacts/2 Nm

Fire performance Absence of halogen IEC 60754-1 Acidity of combus-

09

IEC 60754-2

tion gases

Number of tubes

Max. number of fibers

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m 18 × m

12 24 36 48 60 72 96 120 144 216

Outer Ø

Weight

mm

kg/km

5.8 5.8 5.8 5.8 5.8 5.8 6.8 7.8 8.8 9.1

26 26 26 26 26 26 39 52 68 73

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

FTTH applications

261

FiberConnect® Outdoor cable with stranded multi-fiber loose tubes

Outer jacket Swelling tape Rip cord Loose tube, gel-filled

Fiber optic cables (SM / MM)

Mini multi-fiber loose tube cable, rodent-protected

Strain relief elements GFR strength member

A-DQ(ZN)B2Y n×m… Order no.

84 376 Q Q Q Q

Standardisation

IEC 60794-5

Description

Thermal properties

Non-metallic rugged mini cable suitble for blowing into FTTH

Transport/storage

– 25 °C to + 70 °C

conduit systems.

Installation

– 5 °C to + 50 °C

Operating tempe-

– 25 °C to + 70 °C

rature

Composition Cable core

GFR strength member with stranding elements, designed as gel-filled loose

Mechanical properties

tubes 1.6 mm and, if applicable, dummy

Min. bending radius static dynamic

elements and swelling tape Armour

15 × outer diameter 20 × outer diameter

Multifunctional, reinforced glass rovings

Max. pull force

1500 N

as non-metallic strain relief elements

Max. crush resistance

1500 N/dm

and rodent protection Cable jacket

HDPE jacket with imprint

Fire performance

Colour of jacket

O black

Absence of halogen IEC 60754-1 Acidity of combustion gases

Number of tubes

Max. number of fibers

1×m 2×m 3×m 4×m 5×m 6×m 8×m 10 × m 12 × m

12 24 36 48 60 72 96 120 144

www.leoni-fiber-optics.com

Outer Ø

Weight

mm

kg/km

8.3 8.3 8.3 8.3 8.3 8.3 9.4 10.3 11.3

68 68 68 68 68 68 84 98 114

IEC 60754-2

09


262

FiberConnect® FTTH indoor cable

Fiber optic cables (SM / MM)

Duplex cable

Outer jacket Tight buffered fiber Strain relief elements

I-V(ZN)H 2… TB600 2.8 Order no.

84 950 120 Q

Standardisation

IEC 60794-2

Description

Thermal properties

For fixed installation inside buildings in cable ducts and

Transport/storage

– 25 °C to + 70 °C

conduits as well as for shunting purposes.

Installation

– 5 °C to + 50 °C

For direct connector assembly.

Operating tempe-

– 5 °C to + 70 °C

rature Composition Cable core

Buffered fiber type TB600,

Mechanical properties

diameter 0.6 mm

outer diameter

2.8 mm

one buffered fiber red, further buffered

Cable weight

7.5 kg/km

fiber yellow (E9/125),

Min. bending radius static

green (G50/125) or blue (G62.5/125)

09

30 mm

dynamic

60 mm

static

15 mm

Strain relief

Non-metallic (aramid)

Cable jacket

Halogen-free, flame-retardant material

G657A1

Colour of jacket

O white

Max. pull force

300 N

Max. crush resistance

100 N/dm

Resistance to impacts

3 impacts/1 Nm

with fiber type

Fire performance Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases Fire load

0.20 MJ/m

www.leoni-fiber-optics.com


FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

263

FiberConnect® FTTH indoor cable

Outer jacket Semi-tight buffered fiber Strain relief elements

Fiber optic cables (SM / MM)

Mini breakout cable

I-V(ZN)H 2… STB900H 2.8 Order no.

84 950 746 Q

Standardisation

IEC 60794-2

Description

Thermal properties

For fixed installation inside buildings in cable ducts and con-

Transport/storage

– 25 °C to + 70 °C

duits as well as for shunting purposes.

Installation

– 5 °C to + 50 °C

Ideal for workstation cabling.

Operating tempe-

– 10 °C to + 70 °C

For direct connector assembly.

rature

Composition

Mechanical properties

Cable core

Buffered fiber type STB900H, diameter

outer diameter

2.8 mm

0.9 mm

Cable weight

8.0 kg/km

one buffered fiber red, further buffered

Min. bending radius static

fiber yellow (E9/125), green (G50/125) or blue (G62.5/125)

with fiber type

30 mm

dynamic

45 mm

static

15 mm

Strain relief

Non-metallic (aramid)

G657A1

Cable jacket

Halogen-free, flame-retardant material

Max. pull force

300 N

Colour of jacket

O white

Max. crush resistance

100 N/dm

Resistance to impacts

3 impacts/1 Nm

Fire performance Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

Smoke density

IEC 61034

Absence of halogen IEC 60754-1 Acidity of combus-

IEC 60754-2

tion gases Fire load

www.leoni-fiber-optics.com

0.20 MJ/m

09


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.