M A N U A L WIRELESS PASSDOOR SWITCH ON 1034FLN
1034-OSE INSTALLATION / MAINTENANCE
TWO THOUSAND SEVENTEEN
15-02-2017
FOR 1034-OSE WIRELESS PASSDOOR SWITCH ON 1034FLN
1
2
3
4
Max. 2 Nm
5
6
7 79 236 991
1
Version 2 28-05-2013
CONNECT RECEIVER TO MOTOR CONTROL
9
8
The set is already programmed ! CONNECTIONS: RECEIVER
FUNCTION
MOTOR
TERMINAL
12/24V
+VCC
TERMINAL
0V
GND
TERMINAL
C
PASSDOOR CONNECTION
TERMINAL 4
S
PASSDOOR CONNECTION
79 236 991
2
Version 2 28-05-2013
06/02/15
Instruction Manual
GB
(WIRELESSBAND 1.01.0) SLIM) (WIRELESSBAND
Translation of the original instructions
TÜV Certificate nºM6A 14 12 90800 001
1. GENERAL
Radio transmission system for resistive safety edges. The system consists of a transmitter unit and a receiver unit. Important: - Insert battery 1 first and then battery 2! Unless this order is observed, correct function is not guaranteed. The batteries must be suitable for use at temperatures of -20°C and above
1.1 SAFETY INSTRUCTIONS - Reaction time < 60ms (according TÜV test report AV86368T Certificate nº M6A 14 12 90800 001) - EN13849-1 Cat2 PL-C with TEST. - Device with SELV/PELV Power Supply
2.2 RECEIVER
2.1 TRANSMITTER
4
7
6
3
5
1 2
1234567-
Terminals Battery1 CR2032 Battery 2 CR2032 LED DIP - Switch Push button Antenna
2.1.1 TRANSMITTER TYPICAL CONNECTIONS 1 1
2 2
3
Safety Edge Common Safety Edge Common
Safety Edge
Safety Edge Com
2
3 3
4
4 5
1234567-
1
2
Terminals LED 1 Push button DIP - Switch LED 2 Buzzer Antenna
2.2.1 RECEIVER CONNECTIONS 2
VCC1 VCC2
Inhibitor
2.1.1 OTHER TRANSMITTER CONNECTIONS 1 2
6
7
1
Resistive Safety Edge 8K2 or Resistive Safety Edge 8K2 or Mechanical Safety Edge Mechanical Safety Edge (Choose in transmitter options (Option 1)) (Choose in transmitter options (Option 1))
1
3
3
C
4
5
B
S
6
7
TEST
TEST RELAY (Choose transmitter option 3 for contact NO or NC)
+/~ -/~ 12/24V AC/DC
OUTPUT TYPE - Contact (3-5) - Resistive safety edge 8k2 (3-4) 8K2
System safety
B
C
S
B
C
S
Common Inhibitor Com Inhibitor
Contact Inhibition Contact Inhibition Resistive Safety Edge 8K2 oror Resistive Safety Edge 8K2 Mechanical Safety Edge Mechanical Safety Edge (Choose in in transmitter options (Option 1))1)) (Choose transmitter options (Option
Fail / Sensor active / Sensor not memorized
2.2.2 LED INDICATOR LED ON - Security OK LED OFF - Obstacle detected
2.1.3 TRANSMITTER OPTION SELECTOR
2.2.3 RECEIVER OPTION SELECTOR ON
ON
SAFETY EDGE TYPE
1
2
ON
1
Resistive safety edge
CLASS 2
1
2
1
2
ON
1
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
Enabled (Conforms normative UNE-EN 13849-2) Disabled (Stock configuration)
ON
ON
TRANSMITTER FREQUENCY
1 ON
Contact safety edge 869,85 Mhz (setting MUST match that of receiver) 868,95 Mhz (setting MUST match that of receiver)
TRANSMITTER FREQUENCY
1 ON
1
2
869,85 Mhz (setting MUST match that of transmitter) 868,95 Mhz (setting MUST match that of transmitter)
ON
RECEIVER TYPE TEST
1 ON
1
Normally Open contact Normally Close contact
ON
AUTOMATIC FREQUENCY AGILITY
1 ON
1
WIRELESSBAND 1.0 SLIM
Enabled Disabled
1-2
06/02/15
GB 3. START-UP 2
-
+
l
ium cel
l
0 CR2 32
12/24V
0V
ium cel
l
ith
l
ith
0 CR2 32
l
+
+ +
0 CR2 32
ith
1
AC/DC
PROG.
2. CONNECT RECEIVER POWER SUPPLY
ium cel
l
1. INSERT BATTERIES
M
>1m
3. CHECK OPTION SELECTORS
12/24V
220V
CONTROL UNIT
4. CARRY OUT CODE MEMORIZATION (POINT 4.)
5. INSTALL AND WIRE TRANSMITTER ON DOOR
OK?
RECEIVER
ON
TRANSMITTER
6. MINIMUM DISTANCE 1 m.
7. INSTALL AND WIRE RECEIVER
OK?
9. TEST SAFETY EDGE ON DOOR
8. TURN ON POWER SUPPLY
4. PROGRAMMING PROCESS CODE MEMORIZATION
1.5s PROG.
10s
PROG.
PRESS RECEIVER
1 X BEEP
RELEASE
MEMORY RESET
1 X BEEP
WAIT
2 X BEEP
SAVE & EXIT
3s
1.5s PROG.
PROG.
PRESS RECEIVER
PRESS TRANSMITTER BUTTON
1 X BEEP
KEEP IT PRESSED
PROG.
# BEEPS
RELEASE
10s
WAIT
2 X BEEP
SAVE & EXIT
MEMORY FULL INDICATOR In case of full memory you will hear several acoustic signals for 10 seconds upon trying to memorize a new transmitter. LOW BATTERY INDICATOR Low battery indication consists on 4 acoustic sounds each time a message is received from a programmed transmitter. Both, warning LED and buzzer are set on simultaneously. TECHNICAL SPECIFICATIONS
Receiver suply voltatge Transmitter suply voltatge Receiver memory Receiver Output Receiver Power consumption Ball pressure test (IEC 695-10-2) Pollution degree Protection class (IEC 60529) Frecuency Channels Range Working temperature Software Rated transient over voltage Transmitter power consumption Machine Security Normative Reaction time
12/24 AC/DC 2x lithium battery 3V DC type CR2032 14 transmitters Relay,micro disconnection 1B 0.5 W - 12 V / 1,2 W - 24 V PCB (125ºC) WRAP (75ºC) 2 Ip55 868.95MHz & 869.85MHz 100m -35ºC to +55ºC Class A 330V Transmitting 17mA / stand by 16uA 13849-2008 PL-C Category 2, with TEST 60 ms (according TÜV test report AV86368T Certificate nº M6A 14 12 90800 001)
WARNING!! - Installation, start-up, modification and retrofitting of the system may only be carried out by a qualified person. - Switch off the operating voltage before working on the system. - The system doesn’t have fuse protection. Is recommended include exterior protection minimum 100mA and maximum 250mA.
CE DECLARATION OF CONFORMITY Aplicaciones electrónicas y de Radiofrecuencia S.L Pol. Sot dels Pradals C/ Sot dels pradals, 4 08500 Vic (Barcelona) B61840732 DECLARES, under her own responsibility that product complies with the requirements of the R&TTE 99/05/CE European parliament directive of March 9th 1999. This directive was transposed to the Spanish legislation by means of Real Decree 1890/2000 in November 20th of 2000. For more information visit the website www.aerf.eu