force668LM
manual
manual – force669LM
MANUAL CONNECTING POWER SUPPLY FORCE668LM SLIDE BOLT
Unscrew 4 torxscrews in de ForceIQ control box and put the control board upside down
Plug the power supply connectors onto the main board (will only fit one way)
take the power supply out of the box
Snap the power supply onto the plasRc rail of the circuitboard housing
Replace the control box housing in the main control box and Rghten the 4 torx screws
www.flexiforce.com
2
manual – force669LM
ConnecRng LM668 to Force IQ control box. If lock works the wrong way round then swap KL14 and KL15
www.flexiforce.com
3
manual – force669LM SPECIAL SETUP
PROGRAM LOCK 668LM IN FORCE IQ
SPRECIAL SETUP AUTO CLOSE
SPECIAL SETUP AUTO OPEN
SPECIAL SETUP PARTIAL OPEN
SPECIAL SETUP RELAYS
RELAY 1 INACTIVE
R1 TYPE INACTIVE
R1 TYPE END POS.
R1 TYPE MOVEMENT
R1 TYPE EL.LOCK
MODE LOCK OPEN
PRERUN 1 SEC
CONFIRM:SAVE OTHER KEY: ESC.
www.flexiforce.com
4
manual – force669LM
MODE LOCK OPEN
PRERUN 1 SEC
CONFIRM:SAVE OTHER KEY: ESC.
RELAY 1 EL.LOCK
RELAY 2 INACTIVE
R2 TYPE INACTIVE
R2 TYPE END POS.
R2 TYPE MOVEMENT
R2 TYPE EL.LOCK
MODE LOCK OPEN
MODE LOCK CLOSE
CONFIRM:SAVE OTHER KEY: ESC.
RELAY 2 EL.LOCK
SPECIAL SETUP RELAYS
www.flexiforce.com
BACK TO MAIN MENU
5