SBA-SENSOR Automatic bottom adjustment
SBA-SENSOR Automatische vloer aanpassing
DEUTSCH ENGLISH
Automatische Bodenanpassung
NEDERLANDS
SBA-SENSOR
SBA - SENSOR
ENGLISH
The SBS-Sensor is used for automatic bottem adjustment when using sectional -, industrial- and high-speed doors. It solves all problems that may occur by elongation of ropes or changes in bottom condition (floor pavement). These circumstances normaly make a readjustment of the final end positions necessary. If you use the SBA-Sensor this is a thing of the past.
INSTALLATION OF THE SBA-SENSORS During the installation of the SBA-Sensors the whole unit has to be de-energized!
Installation of the SBA - Sensors directly at the door Fix the SBA-Sensor with 2or 4 screws (sheet-metal screws M6) directly on the surface of the door. In this case the sensor has to be assembled in a way that the extended plunger is positioned approximately at the same level as the bottom edge of the rubber-lip. The plunger has to be brought in this position by unsrewing it.
door plug socket sheet metal screws
bottom edge rubber-lip
plunger 2
SBA - SENSOR Connect the SBA-Sensor (2-phase) to the existing clamp or clip it on the board in the door plug socket! The GREEN wire (Signal) has to be connected to the OSE rail. The BROWN wire has to be connected to the helix cable.
cabelentries
cover
ENGLISH
Installation of the SBA - Sensors in the door plug socket
gasket
microswitch plug screwterminal Art. No. 920091000010
board counternut
plunger plug plugterminal Art. No. 920092000010
3
SBA - SENSOR
ENGLISH
Connection and wiring diagramm
2 01
LERN
GN RT GE
TASTATUR ZEIT 67
345
+12V SIG 0V
TOP
89
8,2 kV J1 OSE
ZU
white IMP
green brown
Schloss STOP
AUF
grey
yellow
Connection helix cable yellow grey white brown green
SBA-socket Microswitch SK-+S SK -+S SK
SK SK
S+-
SK S+-
S+-
SK
SK
S+-
slack rope switch
4
Copyright. No part of this manual may be reproduced without our prior consent. Subject to changes which are in the interest of technical improvements.
wicket-door or slack rope switch