5 valve actuators 2016

Page 1

Valve Actuators

MAXIMATOR air operated valve actuators are piston type design, and are mounted on a manual valve to provide remote control capability. There are two styles of air actuators available, and selection is based on the valve size, system pressure, and air pressure available. Valve Actuator features:  Piston style valve actuator design offers dependable operation and longer actuator cycle life.

Valve Actuator Index Air to Open / Normally Closed . . . . . . . 2 - 3 Air to Close / Normally Open . . . . . . . . . . . 4

 Yoke

style design offers separation from process fluids and actuator air pressure. This design also indicates stem position and allows for easy stem replacement.

 Actuators are mounted on manual valve bodies to provide remote control capabilities in process applications.  Two

different size actuators are available to cover varying plant air supplies.

 Actuators are made of anodized aluminum, which provides good corrosion resistance.  Actuators

are available in normally open or normally closed configuration.

MAXPRO offers a complete line of high pressure valves, fittings and tubing to compliment the valve actuator line. Note: When selecting multiple items, the pressure rating would be that of the lowest rated component.

Maxpro Technologies, Inc. 7728 Klier Drive South · Fairview Pennsylvania 16415 Phone: 814-474-9191 · Fax: 814-474-9391 website: www.maxprotech.com

All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. MT R4 0516

TECHNOLOGIES

1


Air Valve Actuators

®

Air to Open, Normally Closed

TECHNOLOGIES

www.maxprotech.com

Order Information Select the basic manual valve from the appropriate pressure section, then add the actuator suffix number to the end of the manual valve catalog number.

5.67”

Example: 21V4M071-YMNC, medium duty actuator, normally closed. This valve can be operated at 22,500 psi with an air supply of 100 psi to the valve actuator.

Technical Information Max working pressure for actuator

See table below for specific valve type

Max operating temperature for actuator

-20°F to +200°F

Actuator material

Anodized Aluminum

Air connection size:

1/8” NPT

Actuator Type

Valve Size

Ordering Suffix

Piston Area

A

Medium Duty

1/4” - 3/8” - 9/16”

-YMNC

19.6 in.3

5.64”

2.69”

10.09”

1.57”

Heavy Duty

1/4” - 3/8” - 9/16”

-YHNC

39.2 in.3

7.62”

4.72”

12.59”

1.57”

Heavy Duty

3/4” - 1”

-YHNC

39.2 in.3

8.41”

4.72”

13.27”

2.47”

Valve Series

Air Actuator Type Medium Duty

Ordering Suffix -YMNC

21V4

21V6, 15V4, **

21V9, 15V6, 15V8, **

21V12

21V16

Heavy Duty

-YHNC

Medium Duty

-YMNC

-YHNC

Medium Duty

-YMNC

Data Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.)

1-4

6

65 0.19

65 0.19

8

35 0.19

35 0.19

Heavy Duty

-YHNC

(2) 9/32” Dia. Mounting Holes Centered 1 1/8” apart

10

65 75 0.19 0.25 0.25 35 40 0.19 0.25 0.25

12

14

16

18

20

22

85 0.31

95 0.38

45 0.31

50 0.38

95 0.44 0.19 50 0.44 0.19

95 0.50 0.12 50 0.50 0.12

95 0.56 0.06 50 0.56 0.06

100 0.59 0.03 55 0.59 0.03

65

65

75

85

95

95

95

95

0.19

0.19

0.25

0.31

0.38

0.44

0.50

0.56

0.19

0.12

0.06

0.25

Air Pressure (psi)

35

35

40

45

50

50

50

50

Spring Pre-comp. (in.)

0.19

0.19

0.25

0.31

0.38

0.44

0.50

0.56

.019

0.12

0.06

0.25

Air Pressure (psi)

85

90

95

95

Spring Pre-comp. (in.)

0.31

0.34

0.47

0.56

0.15

0.06

65

70

75

75

75

0.28

0.34

0.44

0.50

0.56

0.19

0.12

0.06

0.25

Air Pressure (psi)

50

55

Spring Pre-comp. (in.)

0.19

0.22

Stem Travel (in.) Air Pressure (psi)

65

75

75

Spring Pre-comp. (in.)

0.28

0.38

0.56

0.25

Max. Flow Pressure Value (psi) Cv* 22,500 0.310.22 22,500

18,250 0.750.57 18,250

9,800

0.25

Stem Travel (in.) -YHNC

1/8” NPT

3.94”

Air Pressure (psi)

Stem Travel (in.) -YHNC

D

Spring Pre-comp. (in.)

Stem Travel (in.)

Heavy Duty

C

Air Pressure Required to Open Valve At: System Pressure (ksi)

Stem Travel (in.)

Heavy Duty

Heavy Duty

B

1.290.53 15,700

9,200

0.800.78

6,100

2.730.15

0.06

Air Pressure (psi)

75

75

Spring Pre-comp. (in.)

0.38

0.56

Stem Travel (in.)

0.25

0.06

* Cv value is for straight pattern vee stem valves. Increase this value by 50% for angle pattern valves. Cv Values vary due to compression of actuator spring, and are adjusted based on system pressure. Values shown are for maximum to minimum stem travel position. ** All pipe valves are rated 15,200 psig maximum working pressure, unless air operator is the limiting factor.

2

All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. MT R4 0516


Air Valve Actuators

®

Air to Open, Normally Closed

TECHNOLOGIES

www.maxprotech.com

5.67”

Heavy Duty Actuator

Medium Duty Actuator 1/8” NPT

3.94”

(2) 9/32” Dia. Mounting Holes Centered 1 1/8” apart Valve Series

36V4

36V6, 36V9

65V4, 65V6

Air Actuator Type

Order Suffix

Medium Duty

-YMNC

Heavy Duty

-YHNC

Medium Duty

-YMNC

Heavy Duty

-YHNC

Medium Duty

-YMNC

Heavy Duty

-YHNC

Medium Duty

-YMNC

65V9 Heavy Duty

101V5

(2) 9/32” Dia. Mounting Holes Centered 1 1/8” apart

Heavy Duty

-YHNC

-YHNC

Air Pressure Required to Open Valve At: System Pressure (ksi) Data

Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.) Air Pressure (psi) Spring Pre-comp. (in.) Stem Travel (in.)

Max. Flow Pressure Value (psi) Cv*

1-12

14

16

18

20

22

24

26

28

30

36

45 0.12

55 0.19

55 0.19

55 0.19

55 0.19

65 0.25

65 0.25

65 0.25

75 0.31

85 0.37

25 0.12

30 0.19

30 0.19

30 0.19

30 0.19

35 0.25

35 0.25

35 0.25

40 0.31

45 0.37

36,000

55 .019

55 .019

65 0.25

65 0.25

75 .031

75 0.31

85 .038

85 0.38

95 0.44

100 0.5

36,000

30 0.19

30 0.19

35 0.25

35 0.25

40 0.31

40 0.31

45 0.38

45 0.38

50 0.44

55 0.5

36,000

1-15 55 0.12

20 65 0.19

25 65 0.19

30 65 0.19

35 75 0.25

45 85 0.31

50 85 0.31

55 85 0.31

60 95 0.38

65 100 0.38

65,000

0.08

30 0.12

35 0.19

35 0.19

35 0.19

40 0.25

45 0.31

45 0.31

45 0.31

50 0.38

55 0.44

65,000

0.09

55 0.12

65 0.19

65 0.19

95 0.38

95 0.38

30 0.12

35 0.19

35 0.19

45 0.31

50 0.38

50 0.38

0.14

30 40 0.19

60 50 0.25

70 55 0.28

80 60 0.31

95 0.50 0.12 50 0.50 0.12 101

65,000

20 35 0.12

95 0.44 0.19 50 0.44 0.19 90 70 0.38

100 0.56 0.06 55 0.56 0.66

1-10 35 0.12

75 75 0.25 0.25 0.25 40 40 0.25 0.25 0.25 40 50 40 45 0.19 0.22 0.12

65 0.25 0.19 35 0.25 0.19 75 0.31 0.19 40 0.31 0.19 40 75 0.25 0.25 40 0.25 0.25 85 0.31

90,000

0.090.07

36,000

0.12

0.33

* Cv value is for straight pattern vee stem valves. Increase this value by 50% for angle pattern valves. Cv Values vary due to compression of actuator spring, and are adjusted based on system pressure. Values shown are for maximum to minimum stem travel position.

All general terms and conditions of sale, including limitations of our liability, apply to all products and services sold. MT R4 0516

3


Air Valve Actuators

®

Air to Close, Normally Open

TECHNOLOGIES

www.maxprotech.com

Order Information Select the basic manual valve from the appropriate pressure section, then add the actuator suffix number to the end of the manual valve catalog number. Example: 21V4M071-YMNO, medium duty actuator, normally open. This valve can be operated at 22,500 psi with an air supply of 100 psi to the valve actuator.

Technical Information Max working pressure for actuator

See table below for specific valve type

Max operating temperature for actuator

-20°F to +200°F

Actuator material

Anodized Aluminum

Air connection size:

1/8” NPT Valve Size

Actuator Type

Ordering Suffix

Piston Area

A 3

B

C

Medium Duty

1/4” - 3/8” - 9/16”

-YMNO

19.6 in.

5.64”

2.69”

1.57”

Heavy Duty

1/4” - 3/8” - 9/16”

-YHNO

39.2 in.3

7.63”

4.72”

1.57”

Medium Duty

3/4” - 1”

-YMNO

19.6 in.3

6.43”

2.69”

2.47”

Heavy Duty

3/4” - 1”

-YHNO

39.2 in.3

8.42”

4.72”

2.47”

Valve Series

Air Actuator

(2) 9/32” Dia. Mounting Holes Centered 1 1/8” apart

Air Pressure Regulated to Close Valve At: System Pressure (ksi)

Type

Ordering Suffix

Medium Duty

-YMNO

40

40

40

40

50

60

70

70

Heavy Duty

-YHNO

20

20

20

20

25

30

35

40

21V6, 15V4, **

Medium Duty

-YMNO

45

45

45

45

55

65

75

85

95

100

Heavy Duty

-YHNO

25

25

25

25

30

35

40

45

50

55

21V9, 15V6, ** 15V8, **

Medium Duty

-YMNO

60

60

65

80

100

Heavy Duty

-YHNO

30

30

30

40

50

Medium Duty

-YMNO

80

80

100

Heavy Duty

-YHNO

40

40

50

60

Heavy Duty

-YHNO

50

50

70

100

21V4

21V12 21V16

36V4 36V6 36V9

65V4 65V6 65V9

101V4 101V5 101V6 101V9

1-3

4

6

8

10

12

14

16

18

Max. Pressure (psi)

20

22

85

95

100

22,500

45

50

55

22,500

60

22,500

22,500 10,700

55

60

70

80

85

90

22,500 6,100

75

90

100

13,600 8,800

1-12

14

16

18

20

22

24

26

28

30

36

Medium Duty

-YMNO

25

25

30

35

35

40

45

50

50

55

65

36,000

Heavy Duty

-YHNO

15

15

15

20

20

20

25

25

25

30

35

36,000

Medium Duty

-YMNO

30

35

40

45

50

55

60

65

70

72

85

36,000

Heavy Duty

-YHNO

15

20

20

25

25

30

30

35

35

40

50

36,000

1-15

20

25

30

35

40

45

50

55

60

65

Medium Duty

-YMNO

30

30

30

35

45

50

55

60

70

75

80

65,000

Heavy Duty

-YHNO

15

15

15

20

25

25

30

30

35

40

45

65,000

Medium Duty

-YMNO

35

35

40

50

55

65

70

75

85

90

95

65,000

Heavy Duty

-YHNO

20

20

20

25

30

35

35

40

45

45

50

65,000

Medium Duty Heavy Duty

-YMNO -YHNO

1-10

20

30

40

50

60

70

80

90

101

50

50

50

50

55

65

75

85

95

100

30

30

30

30

30

35

40

40

45

50

Stem Travel (in.)

Flow Value Cv*

0.25

0.31

0.25

0.75

0.38

1.30

0.44

2.50

0.56

3.40

0.19

0.19

0.25

0.12 0.23 0.33

0.08 0.09

0.25

0.14

0.12

0.09

101,000 101,000

* Cv value is for straight pattern vee stem valves. Increase this value by 50% for angle pattern valves. Cv valves vary due to compressionof actuator spring, and are adjusted based on system pressure. Values shown are for maximum to minimum stem travel position. ** All pipe valves are rated 15,200 psig maximum working pressure, unless air operator is the limiting factor. All general terms and conditions of sale, including limitations of

4

our liability, apply to all products and services sold. MT R4 0516


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.