Northman
www.northmanfp.com
2
Index Pressure Control Valves
Page(s)
Direct Acting Relief Valves Pilot Control RF-G01 (0.5 GPM Max.) Direct RF-G02 (4.2 GPM Max.)
4 6
Standard RF-*04/06/10 (100 GPM Max.) Low Noise HRF-*04/06/10 (105.6 GPM Max.)
10 14
Standard SRF-*04/06/10 (100 GPM Max.) Low Noise HSRF-*04/06/10 (105.6 GPM Max.)
17 23
Sequence, Unloading, Counterbalance, Relief: SV & SCV Series (66 GPM Max.)
26
Pressure Reducing PRV & PRCV Series (66 GPM Max.)
34
MF-02 (RF-G01/G02) MF-04/06/10 (RF, HRF, SRF, HSRF) SVM-03/06/10 (SV, SCV, PRV, PRCV)
42 44 46
Restrictors Sub Plates
50 58
Lift Valve Pressure Switch
60 62
Pilot Operated Relief Valves
Solenoid Controlled Relief Valves
Pressure Control
Subplates
Flow Control Valves
Accessory Valves
Northman
www.northmanfp.com
33
REMOTE CONTROLLED RELIEF VALVE RF-G01 SERIES
FEATURES •This adjustable pressure relief valve is designed as a remote control valve for a pilot operated pressure control valve.
Symbol
Model Code
Northman
www.northmanfp.com
4
REMOTE CONTROLLED RELIEF VALVE RF-G01 SERIES SPECIFICATIONS MODEL
MAX. PRESSURE BAR (PSI)
PRESSURE ADJ. RANGE BAR(PSI)
FLOW RATE LPM(GPM)
MOUNTING BOLTS MM(INCH)
RF-G01
245(3550)
1:7-69(100-1000) 2:35-138(500-2000) 3:69-245(1000-3550)
2(0.5)
M5x40Lx4 PCS (#10-24UNC-1-1/2"x4 PCS)
DIMENSIONS
Northman
www.northmanfp.com
UNIT: mm(inch) WEIGHT: 1.5 kgs(3.4 lbs)
55
DIRECT TYPE RELIEF VALVE RF-G02 SERIES
FEATURES •This adjustable pressure relief valve is a direct acting valve designed for applications requiring a valve of small maximum flow capacity.
Symbol
Model Code
Northman
www.northmanfp.com
6
DIRECT TYPE RELIEF VALVE RF-G02 SERIES SPECIFICATIONS MODEL
MAX. PRESSURE BAR(PSI)
RF-G02
207(3000)
PRESSURE ADJ. RANGE BAR(PSI) 1:7-69(100-1000) 2:35-138(500-2000) 3:69-207(1000-3000)
PERFORMANCE CURVES TEST CONDITIONS Viscosity: 35 cSt (175 SSU) Temperature: 50째 C (122째 F) MIN. ADJ. PRESSURE
NOMINAL OVERRIDE
Northman
www.northmanfp.com
77
FLOW RATE LPM(GPM)
MOUNTING BOLTS MM(INCH)
16(4.2)
M5x40Lx4 PCS (#10-24UNC-1-1/2"x4 PCS)
DIRECT TYPE RELIEF VALVE RF-G02 SERIES DIMENSIONS
UNIT: mm(inch) WEIGHT: 1.5 kgs(3.4 lbs)
RF-G02
Northman
www.northmanfp.com
8
DIRECT TYPE RELIEF VALVE RF-G02 SERIES DIMENSIONS
UNIT: mm(inch) WEIGHT: 1.5 kgs(3.4 lbs)
MF-02
HOW TO ORDER MF-02-02-N
Northman
E #10-24UNCx12L
F NPT 1/4"
www.northmanfp.com
99
PILOT OPERATED RELIEF VALVE RF SERIES
FEATURES •RF series relief valve is designed on the theory of differential pressure created by flow across the orifice of the balance piston. This differential pressure acts to open the piston against the spring, permitting enough fluid vented to tank at the set pressure. • Piston moves smoothly, and controlled by pilot pressure, provides stable pressure control and good repeatability. Symbol
Model Code
Northman
www.northmanfp.com
10
PILOT OPERATED RELIEF VALVE RF SERIES SPECIFICATIONS MODEL
MAX. PRESSURE BAR (PSI)
PRESSURE ADJ. RANGE BAR (PSI)
MAX. FLOW LPM(GPM)
RF-*04
245 (3550)
1:7-69(100-1000)
100 (25)
RF-*06
2:35-138(500-2000)
200 (50)
RF-*10
3:69-247(1000-3550)
400 (100)
PERFORMANCE CURVES TEST CONDITIONS Viscosity: 35 cSt (175 SSU) Temperature: 50° C (122° F) NOMINAL OVERRIDE MIN. ADJ. PRESSURE
Northman
www.northmanfp.com
11 11
MOUNTING BOLTS (FOR G TYPE) MM(INCH) M12x70L(1/2"x2-3/4") 2PCS M12x90L(1/2"x3-1/2") 2PCS M16x60L(5/8"x2-1/4") 2PCS M16x80L(5/8"x3-1/4") 2PCS M20x70L(3/4"x2-3/4") 2PCS M20x90L(3/4"x3-1/2") 2PCS
PILOT OPERATED RELIEF VALVE RF SERIES DIMENSIONS
UNIT: mm(inch) WEIGHT: 1.5 kgs(3.4 lbs)
RFG-04
RFG-06/10
MODEL RF-G06 RF-G10
A
B
C
D
E
F
G
H
I
J
K
175 (6.89) 184 (7.24)
104 (4.09) 120 (4.72)
160 (6.30) 195 (7.68)
104 (4.09) 125 (4.92)
70 (2.76) 82 (3.23)
66.6 (2.62) 88.9 (3.50)
44.1 (1.74) 63.6 (2.50)
11.1 (1.74) 12.7 (0.50)
19.5 (0.76) 18.5 (0.73)
122 (4.80) 150 (5.91)
23.8 (0.94) 31.8 (1.25)
Northman
www.northmanfp.com
12
WEIGHT KGS LBS 6.7
14.7
10.1
22.1
PILOT OPERATED RELIEF VALVE RF SERIES DIMENSIONS
UNIT: mm(inch) WEIGHT: 1.5 kgs(3.4 lbs)
RF-T*
P PORT
T PORT
G PORT
WEIGHT KGS LBS
111 (4.37) 84.5 (3.33)
PT 1/2"
PT 1/2"
PT 1/4"
3.4
7.5
102 (4.02)
140 (5.51)
103 (4.05)
PT 3/4"
PT 3/4"
PT 1/4"
5.3
11.7
120 (4.72)
183 (7.20)
120 (4.72) PT 1-1/4" PT 1-1/4" PT 1/4"
8.5
18.7
MODEL
A
B
RF-T04 SERIES
MAX. 142 (5.59)
92 (3.62)
RF-T06 SERIES
MAX. 148 (5.83)
RF-T10 SERIES
151 MAX. (5.94)
Northman
www.northmanfp.com
C
13 13
D
LOW NOISE PILOT OPERATED RELIEF VALVE HRF SERIES
FEATURES •HRF series relief valve is designed on the theory of differential pressure created by flow across the orifice of the balance piston. This differential pressure acts to open the piston against the spring, permitting enough fluid vented to tank at the set pressure. • Piston moves smoothly, and controlled by pilot pressure, provides stable pressure control and good repeatability. • Special internal passage design keeps flow noise to a minimum. Symbol
Model Code
Northman
www.northmanfp.com
14
LOW NOISE PILOT OPERATED RELIEF VALVE HRF SERIES SPECIFICATIONS MODEL
MAX. PRESSURE BAR (PSI)
MAX. FLOW LPM (GPM)
MOUNTING BOLTS METER (INCH)
HRF-G03-*-*
242 (3500)
100 (26.4 )
M12x40Lx4(1/2"x1-3/5")
HRF-G06-*-*
200 ( 52.8 )
M16x50Lx4(5/8"x2")
HRF-G10-*-*
400 (105.6)
M20x60Lx4(3/4"x2-2/5")
PERFORMANCE CURVES TEST CONDITIONS Viscosity: 35 cSt (175 SSU) Temperature: 50째 C (122째 F)
Northman
www.northmanfp.com
15 15
LOW NOISE PILOT OPERATED RELIEF VALVE HRF SERIES DIMENSIONS
UNIT: mm(inch) WEIGHT: 1.5 kgs(3.4 lbs)
HRF-G03/G06/G10-R
MODEL HRF-G03 HRF-G06 HRF-G10
A 76(3) 104(4.09) 120(4.72)
B 53.8(2.12) 70(2.76) 82.6(3.25)
C 11.1(0.44) 17(0.67) 18.7(0.74)
D 26.9(1.06) 35(1.38) 41.3(1.63)
MODEL
K
L
N
P
Q
S
T
HRF-G03 HRF-G06 HRF-G10
21(0.83) 25(0.98) 32(1.26)
51(2.01) 51(2.01) 65(2.56)
132(5.2) 132(5.2) 167(6.52)
104(4.09) 104(4.09) 135(5.32)
22(0.86) 27(1.06) 33.5(1.32)
106(4.17) 123(4.84) 155(6.1)
26(1.02) 36.5(1.44) 47(1.85)
Northman
www.northmanfp.com
16
E F G 53.8(2.11) 113.5(4.47) 27(1.06) 66.7(2.63) 98.8(3.89) 33.7(1.33) 88.9(3.5) 89(3.35) 44.9(1.77)
H 171(6.73) 171(6.73) 219(8.62) SUBPLATE TYPE MF-04 MF-06 MF-10
J 13.5(0.53) 17.5(0.69) 21.5(0.85)
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES
FEATURES •SRF-T/G valve is the combination of solenoid operated directional control valve and a RF-G relief valve in one integrated body to provide a wide variety of pressure control possibilities. Solenoid control permits convenient electrical selection of system pressures. Selection for pressure or vent, either of two pressures, or two pressures and vent, or one of three pressures can be achieved by proper selection of the valves listed below.
Model Code
Northman
www.northmanfp.com
17 17
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES SPECIFICATIONS MODEL
MAX. PRESSURE BAR (PSI)
RATED FLOW LPM(GPM)
PRESSURE ADJ. RANGE BAR (PSI)
SRF-G04 SRF-G/T06 SRF-G10
245 (3550)
100(26.4) 200(52.8) 400(105.6)
1: 7-69 (100-1000) 2: 35-138(500-2000) 3: 69-245(1000-3550)
SYMBOLS & FUNCTION TABLES
MODEL 1PN 1NP 2P 2PN
3P
Northman
INPUT SOL b OFF ON NONE OFF ON OFF ON OFF OFF ON OFF
SOL a NONE OFF ON NONE OFF OFF ON OFF OFF ON
www.northmanfp.com
OUTPUT VENTED ADJUSTABLE PRESSURE ADJUSTABLE PRESSURE VENTED ADJUSTABLE PRESSURE AT A ADJUSTABLE PRESSURE AT B VENTED ADJUSTABLE PRESSURE AT A ADJUSTABLE PRESSURE AT B ADJUSTABLE PRESSURE AT C ADJUSTABLE PRESSURE AT A ADJUSTABLE PRESSURE AT B
18
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES DIMENSIONS SRF-G*-1PN/1NP
MODEL SRF-G04 SERIES SRF-G06 SERIES SRF-G10 SERIES MODEL SRF-G04 SERIES SRF-G06 SERIES SRF-G10 SERIES
Northman
A 228.5 (9) 254 (9.61) 281 (11.06)
B 175 (6.89) 175 (6.85) 184 (7.24)
C 78 (3.07) 78 (3.07) 87.5 (3.45)
D 78 (3.07) 60 (2.36) 67 (2.64)
E 57 (0.67) 40 (0.67 47 (0.71)
L
M
N
Y
Z
0 (0) 23.8 (0.94) 31.8 (1.25)
47.5 (2.13) 55.5 (2.19) 76.2 (3.00)
22 (0.87) 11 (0.43) 12.7 (0.50)
13.5 (0.53) 17.5 (0.69) 22 (0.85)
21 (0.83) 26 (1.02) 32 (1.26)
www.northmanfp.com
19 19
G 82 (3.23) 102 (4.09) 124 (4.88) WEIGHT KGS(LBS) 7.5 KGS (16.5 LBS) 8.0 KGS (17.6 LBS) 25 KGS (55.1 LBS)
H 53.8 (2.12) 70 (2.76) 82.6 (3.25) SUBPLATE TYPE MF-04 MF-06 MF-10
J 21.5 (0.89) 19 (0.67) 20 (0.71)
K 53.8 (2.12) 66.7 (2.63) 88.9 (3.5)
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES DIMENSIONS SRF-G06/G10-2P
MODEL
A
G
104 244 (9.61) (4.09) 281 124 SRF-G10 SERIES (11.06) (4.88) SRF-G06 SERIES
Northman
H
J
K
L
M
N
Y
Z
70 (2.76) 82.6 (3.25)
16.9 (0.67) 18 (0.71)
66.7 (2.63) 88.9 (3.5)
23.8 (0.94) 31.8 (1.25)
55.5 (2.19) 76.2 (3.00)
11 (0.43) 12.7 (0.50)
17.5 (0.69) 21.5 (0.85)
26 (1.02) 32 (1.26)
www.northmanfp.com
20
WEIGHT KGS(LBS) 10 KGS (22.0LBS) 27 KGS (59.5LBS)
SUBPLATE TYPE MF-06 MF-10
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES DIMENSIONS SRF-G06/G10-2PN
SRF-G06/G10-3P
MODEL
A
SRF-G06 SERIES SRF-G10 SERIES
Northman
G
244 104 (9.61) (4.09) 281 124 (11.06) (4.88)
H
J
K
L
M
N
Y
Z
70 (2.76) 82.6 (3.25)
16.9 (0.67) 18 (0.71)
66.7 (2.63) 88.9 (3.5)
23.8 (0.94) 31.8 (1.25)
55.5 (2.19) 76.2 (3.00)
11 (0.43) 12.7 (0.50)
17.5 (0.69) 21.5 (0.85)
26 (1.02) 32 (1.26)
www.northmanfp.com
21 21
WEIGHT KGS(LBS) 12 KGS (26.4LBS) 29 KGS (63.9LBS)
SUBPLATE TYPE MF-06 MF-10
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES DIMENSIONS
UNIT: mm(inch) WEIGHT: 8kgs(17.6lbs)
SRF-T06-1PN/1NP
SRF-T06-2P/2PN/3P
Northman
www.northmanfp.com
22
LOW NOISE SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE HSRF SERIES
FEATURES •HSRF-G valve is the combination of solenoid operated directional control valve and a HRF-G relief valve in one integrated body to provide a wide variety of pressure control possibilities. Solenoid control permits convenient electrical selection of system pressures. Selection for pressure or vent, either of two pressures, or two pressures and vent, or one of three pressures can be achieved by proper selection of the valves listed below. • Special internal passage design keeps flow noise to a minimum.
Model Code
Northman
www.northmanfp.com
23 23
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES SPECIFICATIONS MODEL HSRF-G03-*
MAX. PRESSURE BAR(PSI) 242 (3500)
HSRF-G06-*
MAX. FLOW LPM (GPM)
MOUNTING BOLTS METER (INCH)
100 (26.4 )
M12x40Lx4 (1/2"x1-3/5")
200 (52.8 )
M16x50Lx4 (5/8"x2")
SYMBOLS
Northman
www.northmanfp.com
24
SOLENOID CONTROLLED PILOT OPERATED RELIEF VALVE SRF SERIES DIMENSIONS HSRF-G03/06/-1PN/1NP-R
UNIT: mm(inch)
MODEL HSRF-03 HSRF-06
A 76(3) 104(4.09)
B 53.8(2.12) 70(2.76)
C 11.1(0.44) 17(0.67)
D 26.9(1.06) 35(1.38)
E F G 53.8(2.11) 113.5(4.47) 27(1.06) 66.7(2.63) 98.8(3.89) 33.7(1.33)
H 171(6.73) 171(6.73)
J 13.5(0.53) 17.5(0.69)
MODEL HSRF-03 HSRF-06 HSRF-10
K 21(0.83) 25(0.98) 32(1.26)
L 48(1.89) 48(1.89) 48(1.89)
N 220.5(8.7) 220.5(8.7) 235(9.25)
P 206.8(8.1) 206.8(8.1) 220(8.66)
Q 157(6.18) 157(6.18) 172(6.77)
U 22(0.86) 27(1.06) 37(1.46)
V 106(4.17) 123(4.84) 152(5.98)
MODEL HSRF-G03 HSRF-G06
X 26(1.02) 36.5(1.44)
Northman
SUBPLATE TYPE MF-04 MF-06
www.northmanfp.com
25 25
S 132(5.2) 132(5.2) 146(5.75)
T 104(4.09) 104(4.09) 120(4.72)
PRESSURE CONTROL VALVE H & HC TYPE
FEATURES •This series of valve is configured at assembly to function as either a relief valve, sequence valve, unloading valve, or counterbalance valve. They are available with or without a reverse free flow check valve. SYMBOLS
Model Code
Northman
www.northmanfp.com
26
PRESSURE CONTROL VALVE H & HC TYPE SPECIFICATIONS MODEL
MAX. PRESSURE BAR (PSI)
PRESSURE ADJ.RANGE BAR (PSI) 0: 17-35(250-500)
MAX. FLOW LPM(GPM) 50(13)
207 (3000)
1: 35-69 (500-1000)
125(33)
2: 35-138(1000-2000)
250(66)
SV/SCV-*03 SV/SCV-*06 SV/SCV-*10
VALVE TYPE
PERFORMANCE CURVES PRESSURE DROP FOR REVERSED FREE FLOW
Northman
www.northmanfp.com
27 27
PRESSURE CONTROL VALVE H & HC TYPE DIMENSIONS UNIT: mm(inch)
SV-G03/06
MODEL
A
B
C
D
E
F
SV-G03 60 (2.36) 67 (2.64) 41.7 (1.64) 39 (1.54) 89 (3.50) 195 (7.68)
H
BOLT METER(INCH)
170.3 (6.70)
52.3 (2.06)
M10x50x4PCS (3/8"x2"x4PCS)
4
8.8
M10x50x4PCS (3/8"x2"x4PCS)
6.1
13.4
SV-G06 73 (2.87) 81 (3.19) 41.5 (1.63) 39 (1.54) 102 (4.02) 219 (8.62) 192 (7.56) 51 (2.01)
Northman
www.northmanfp.com
28
WEIGHT KGS LBS
G
PRESSURE CONTROL VALVE H & HC TYPE DIMENSIONS SV-G10
Northman
UNIT: mm(inch)
www.northmanfp.com
29 29
PRESSURE CONTROL VALVE H & HC TYPE DIMENSIONS UNIT: mm(inch)
SCV-G03/06
MODEL
A
B
C
D
E
F
G
H
M10x70x4PCS (3/8"x2 -3/4"x4PCS) M10x80x4PCS SCV-G06 108 (4.25) 69 (2.72) 40 (1.57) 73 (2.87) 102 (4.02) 221 (8.70) 188 (7.40) 51 (2.01) (3/8"x3 -1/4"x4PCS) SCV-G03
Northman
87 (3.43) 59 (2.32) 35 (1.38) 60 (2.36) 89 (3.50) 191 (7.52) 170 (6.69)
www.northmanfp.com
30
49.6 (1.95)
BOLT METER(INCH)
WEIGHT KGS LBS 4.8
10.6
7.8
17.2
PRESSURE CONTROL VALVE H & HC TYPE DIMENSIONS SCV-G10
Northman
UNIT: mm(inch)
www.northmanfp.com
31 31
PRESSURE CONTROL VALVE H & HC TYPE DIMENSIONS UNIT: mm(inch)
SV-T03/06/10
MODEL
A
B
C
D
E
F
G
H
SV-T03
42 (1.65)
84 (3.31)
61 (2.40)
74 (2.91)
195 (7.68)
57 (2.24)
106 (4.17)
43 (1.69)
SV-T06
48 (1.89)
96 (3.78)
73 (2.87)
86 (3.39)
219 (8.62)
SV-T10
68.5 (2.70)
137 (5.39)
84 (3.31)
103 (4.05)
272 (10.71)
MODEL
J
K
L
N
Q
SV-T03
70 (2.76)
0 (0)
28 (1.10)
28 (1.10)
SV-T06
80.5 (3.17)
9 (0.35)
33 (1.30)
SV-T10
98 (3.86)
12 (0.47)
40 (1.57)
Northman
www.northmanfp.com
64.5 (2.54) 123.5 (4.86) 50.5 (1.99) 84 (3.31)
149 (5.87)
WEIGHT KGS
LBS
3/8 (1/2)
3.7
8.1
42 (1.65)
3/4 (1)
6.2
13.6
52 (2.05)
11/4 (11/2)
12
26.4
32
66 (2.60)
PRESSURE CONTROL VALVE H & HC TYPE DIMENSIONS UNIT: mm(inch)
SCV-T03/06/10
MODEL
A
B
C
D
E
F
G
H
SCV-T03
41 (1.61)
82 (3.23)
63 (2.48)
96 (3.78)
194 (7.64)
59 (2.32)
110 (4.33)
43 (1.69)
SCV-T06
50 (1.97)
100 (3.94)
76 (2.99)
118 (4.65)
223.5 (8.80)
64.5 (2.54)
123.5 (4.86)
50.5 (1.99)
SCV-T10
68.5 (2.70)
137 (5.39)
84 (3.31)
156 (6.14)
269 (10.59)
84 (3.31)
149 (5.87)
66 (2.60)
MODEL
J
K
L
N
Q
SCV-T03
70 (2.76)
0 (0)
28 (1.10)
28 (1.10)
SCV-T06
80.5 (3.17)
9 (0.35)
33 (1.30)
SCV-T10
98 (3.86)
12 (0.47)
40 (1.57)
Northman
www.northmanfp.com
WEIGHT KGS
LBS
3/8 (1/2)
4.2
4.2
42 (1 65)
3/4 (1)
7.5
16.5
52 (2.05)
11/4 (11/2)
13.8
30.4
33 33
PRESSURE REDUCINGÂ VALVE
FEATURES •The adjustable pressure reducing valve will ensure that the operating pressure in a branch of a hydraulic system will be maintained at a lower setting than that of the main system pressure. It is available with or without a reverse free flow check valve. SYMBOLS
Model Code
Northman
www.northmanfp.com
34
PRESSURE REDUCING VALVE SPECIFICATIONS MODEL
MAX. PRESSURE BAR(PSI)
PRV-*03 PRCV-*03 PRV-*06 PRCV-*06
207(3000)
PRV-*10 PRCV-*10
PRESSURE ADJUSTING RANGE BAR(PSI)
MAX. FLOW LPM(GPM)
MOUNTING BOLTS METER(INCH)
1:7-69(100-1000)
50(13.2)
M10x70(3/8"x2-3/4") 4PCS
2:35-138(500-2000)
125(33)
M10x80(3/8"x3-1/4") 4PCS
3:7-207(1000-3000)
250(66)
M10x90(3/8"x3-1/2") 6PCS
PERFORMANCE CURVES PRESSURE DROP FOR REVERSED FREE FLOW
Northman
www.northmanfp.com
35 35
PRESSURE REDUCING VALVE DIMENSIONS UNIT: mm(inch)
PRV-G03/06
MODEL
A
B
PRV-G03 164 (6.46) 42 (1.65)
C
D
89 (3.23) 44.5 (1.75) 67 (2.64)
PRV-G06 165.8 (6.53) 42 (1.65) 100 (3.94) 50 (1.97)
Northman
E
www.northmanfp.com
F 155.5 (6.12)
G
H
92.4 (3.64) 40.6 (1.60) 35 (1.38)
74 (2.91) 182 (7.17) 111 (4.37) 40 (1.57)
36
J
48 (1.89)
WEIGHT KGS LBS 4.5
10.1
6.8
15.2
PRESSURE REDUCING VALVE DIMENSIONS PRV-G10
Northman
UNIT: mm(inch)
www.northmanfp.com
37 37
PRESSURE REDUCING VALVE DIMENSIONS UNIT: mm(inch)
PRCV-G03/06
MODEL
A
B
C
D
E
F
G
H
J
WEIGHT KGS LBS
PRCV-G03 164 (6.46) 61 (2.40) 90 (3.54) 45 (1.77) 88 (3.46) 155 (6.10) 92.4 (3.64) 45 (1.77) 34.9 (1.37)
5.2
11.45
PRCV-G06 164 (6.46) 70.5 (2.78) 104 (4.09) 52 (2.05) 109 (4.29) 182 (7.17) 111 (4.37) 40 (1.57) 48 (1.89)
8.3
18.28
PRCV-G10 166 (4.57) 79 (3.11) 119 (4.69) 59.5 (2.34) 132 (5.20) 216 (8.50) 146 (5.75) 42 (1.65) 63 (2.48)
18.5
40.78
Northman
www.northmanfp.com
38
PRESSURE REDUCING VALVE DIMENSIONS PRV-T03
Northman
UNIT: mm(inch)
www.northmanfp.com
39 39
PRESSURE REDUCING VALVE DIMENSIONS UNIT: mm(inch)
PRV-T06/10
MODEL
A
B
C
D
E
F
G
H
K
N
PRV-T06 94.8 (3.73) 47.4 (1.87) 150 (5.90) 42 (1.65) 179 (7.06) 97 (3.83) 53.5 (2.11) 33 (1.30) 39 (1.54) 62 (2.44) PRV-T10 132 (5.20) 66 (2.60) 167 (6.57) 52 (2.05) 216 (8.50) 124 (4.88) 64 (2.52) 40 (1.57) 50 (1.97) 79 (3.11)
Northman
www.northmanfp.com
40
P M19 (3/4")
WEIGHT KGS LBS 6
13.2
M32 12 26.45 (1-1/4")
PRESSURE REDUCING VALVE DIMENSIONS UNIT: mm(inch)
PRCV-T06/T10
MODEL
A
B
C
D
E
F
G
H
J
K
N
P
WEIGHT KGS LBS
PRCV-T06
94 48 150 42 179 97.5 44.5 42 9 66 62 (3.70) (1.89) (5.90) (1.65) (7.06) (3.84) (1.75) (1.66) (0.35) (2.60) (2.44)
M19 (3/4")
7.8
17.1
PRCV-T10
137 68.5 167 52 216 124 52 52 12 84 79 (5.40) (2.70) (6.57) (2.05) (8.50) (4.88) (2.04) (2.04) (0.47) (3.31) (3.11)
M32 (1-1/4")
14.4
31.7
Northman
www.northmanfp.com
41 41
SUBPLATE FOR RF-G01 & RF-G02
FEATURES •
Model Code MF-02-02-N
Northman
www.northmanfp.com
42
SUBPLATE FOR RF-G01 & RF-G02 DIMENSIONS MF-**
HOW TO ORDER
E
F
MF-02-02-N
#10-24UNCx12L
NPT 1/4"
Northman
www.northmanfp.com
43 43
SUBPLATE FOR RF-, HRF-, SRF-, HSRF.
FEATURES •
Model Code
Northman
www.northmanfp.com
44
SUBPLATE FOR RF-, HRF-, SRF-, HSRF. DIMENSIONS MF-**
MODEL MF-04 MF-06 MF-10
A 86 (3.39) 108 (4.25) 126 (4.96)
B 60 (2.36) 78 (3.07) 94 (3.70)
MODEL MF-04 MF-06 MF-10
J 123 (4.84) 150 (5.91) 195 (7.68)
L 32 (1.26) 51 (2.01) 62 (2.44)
MODEL
Y
a
b
d
MF-04
32 (1.26)
14.5 (0.57)
11 (0.43)
17.5 (0.69)
MF-06
40 (1.57)
23 (0.91)
13.5 (0.53)
21 (0.83)
MF-10
50 (1.97)
28 (1.10)
17.5 (0.69)
26 (1.02)
Northman
C 13 (0.51) 15 (0.59) 16 (0.63)
D 53.8 (2.12) 70 (2.76) 82.6 (3.25)
E 3.1 (0.12) 4 (0.16) 5.7 (0.22)
F G 26.9 (1.06) 149 (5.87) 35 (1.38) 180 (7.09) 41.3 (1.63) 227 (8.94)
H 13 (0.51) 15 (0.59) 16 (0.63)
N Q T U V X 26 (1.02) 53.8 (2.12) 47.5 (1.87) 0 (0.00) 22.1 (0.87) 22.1 (0.87) 27.2 (1.07) 66.7 (2.63) 55.6 (2.19) 23.8 (0.94) 33.4 (1.31) 11.1 (0.43) 30.2 (1.19) 88.9 (3.5) 76.2 (3.00) 31.8 (1.25) 44.5 (5.44) 12.7 (0.50)
www.northmanfp.com
45 45
e M12x20L (1/2-13UNCx20L) M16x25L (5/8-11UNCx25L) M20x28L (3/4-10UNCx28L)
f 12 (0.47) 12 (0.47) 17 (0.67)
SUBPLATE FOR SV/SCV PRV/PRCV
FEATURES •
Model Code
Northman
www.northmanfp.com
46
SUBPLATE FOR SV/SCV PRV/PRCV DIMENSIONS SVM-03-**
ISO 5781-AG-06-2-A
THIS SUBPLATE IS USED FOR SV/SCV-G03, PRV/PRCV-G03
SUBPLATE
PORT PT
A
B
C
D
E
F
G
SVM-03-03
3/8"
61 (2.40)
21 (0.83)
40.9 (1.61)
-
35 (1.38)
9.6 (0.38)
32 (1.26)
Northman
www.northmanfp.com
47 47
SUBPLATE FOR SV/SCV PRV/PRCV DIMENSIONS SVM-06-**
ISO 5781-AH-08-2-A
THIS SUBPLATE IS USED FOR SV/SCV-G06, PRV/PRCV-G03
SUBPLATE
PORT PT
A
B
C
D
E
F
G
H
J
SVM-06-06
3/4"
124 (4.88)
10 (0.39)
77 (3.03)
27 (1.06)
61.7 (2.43)
-
73 (2.87)
6.4 (0.25)
36 (1.42)
Northman
www.northmanfp.com
48
SUBPLATE FOR SV/SCV PRV/PRCV DIMENSIONS ISO 5781-AJ-10-2-A
SVM-10-**
SUBPLATE
PORT PT
A
B
C
D
E
F
G
SVM-10-10
1-1/4"
150 (5.91)
12 (0.47)
96 (3.78)
30 (1.18)
-
45 (1.77)
13.6 (0.54)
Northman
www.northmanfp.com
49 49
FLOW CONTROLS RESTRICTORS
FEATURES • The TV adjustable valve functions as a needle valve flow restrictor. The TCV adjustable valve functions as a flow control valve, with a needle valve flow restrictor in one direction and free flow in the opposite direction.
Symbol
Model Code
Northman
www.northmanfp.com
50
FLOW CONTROLS RESTRICTORS SPECIFICATIONS MODEL NUMBERS THREAD TYPE SUBPLATE TYPE TV-T03 TV-G03 TCV-T03 TCV-G03 TV-T06 TV-G06 TCV-T06 TCV-G06 TV-T10 TV-G10 TCV-T10 TCV-G10
MAX.OPERATED PRESSURE BAR (PSI)
30 (8) 207 (3000)
PRESSURE DROP FOR REVERSED FREE FLOW
www.northmanfp.com
80 (20) 200 (50)
PERFORMANCE CURVES
Northman
RATED FLOW LPM (GPM)
51 51
WEIGHT KGS (LBS) 1.4(3.1) 1.5(3.1) 2.6(5.7) 3.5(7.7) 5.2(11.5) 7.4(16.3)
1.5(3.1) 2.1(4.6) 2.7(6.0) 4.0(8.8) 6.1(13.5) 8.1(17.8)
FLOW CONTROLS RESTRICTORS DIMENSIONS TV-T03/06/10-** UNIT : WEIGHT : T03 T06 T10
MODEL TV-T03 TV-T06 TV-T10
Northman
mm(inch) kgs(lbs) 1.40(3.08) 2.60(5.72) 5.20(11.44)
A B C D E F G H J L N 70 35 40 143 54 23 42 20 40 19 M10 (2.76) (1.38) (1.57) (5.63) (2.13) (0.91) (1.65) (0.79) (1.57) (0.75) (3/8") 100 50 40 136.5 62 30 62 30 60 19 M19 (3.94) (1.97) (1.57) (5.37) (2.44) (1.18) (2.44) (1.18) (2.36) (0.75) (3/4") 130 65 56 173 73 40 82 40 80 22 M32 (5.12) (2.56) (2.20) (6.81) (2.87) (1.57) (3.23) (1.57) (3.15) (0.87) (1-1/4")
www.northmanfp.com
52
FLOW CONTROLS RESTRICTORS DIMENSIONS TV-G03/06/10-** UNIT : WEIGHT : G03 G06 G10
mm(inch) kgs(lbs) 1.50(3.30) 2.70(5.94) 6.10(13.42)
MODEL TV-G03 TV-G06 TV-G10
A 60 (2.36) 80 (3.15) 100 (3.94)
B 40 (1.57) 58 (2.28) 72 (2.83)
C 20 (0.79) 29 (1.14) 36 (1.42)
D 10 (0.39) 11 (0.43) 14 (0.55)
E 80 (3.14) 92 (3.62) 120 (4.72)
F 60 (2.36) 70 (2.76) 92 (3.62)
G 30 (1.18) 35 (1.38) 46 (1.81)
H 10 (0.39) 11 (0.43) 14 (0.55)
J 45 (1.77) 54 (2.13) 71 (2.80)
MODEL TV-G03
K 15 (0.59)
L 100 (3.94)
N 65 (2.56)
P 30 (1.18)
Q 44 (1.73)
S 19 (0.75)
T 9 (0.35)
U 14 (0.55)
V 8.6 (0.34)
TV-G06
16 (0.63) 117.5 (4.63) 73 (2.87)
42 (1.65)
41.5 (1.63)
23 (0.90)
11 (0.43)
TV-G10
21 (0.83)
55 (2.17)
56 (2.20)
23 (0.90)
13.5 (0.53)
Northman
145 (5.71)
100 (3.94)
www.northmanfp.com
53 53
17.5 (0.69) 10.8 (0.43) 21 (0.83)
1.0 (0.04)
FLOW CONTROLS RESTRICTORS DIMENSIONS TCV-G03/06/10-**
MODEL TCV-G03 TCV-G06 TCV-G10
A B 60 (2.36) 40 (1.57) 80 (3.15) 58 (2.28) 100 (3.94) 72 (2.83)
C 20 (0.79) 29 (1.14) 36 (1.42)
D E F G 10 (0.39) 179 (7.05) 80 (3.14) 60 (2.36) 11 (0.43) 213 (8.39) 95 (3.74) 70 (2.76) 14 (0.55) 228 (8.98) 120 (4.72) 92 (3.62)
MODEL TCV-G03 TCV-G06 TCV-G10
K 10 (0.39) 11 (0.43) 14 (0.55)
N 15 (0.59) 16 (0.63) 21 (0.83)
P 62 (2.44) 74 (2.91) 97 (3.82)
Northman
L 45 (1.77) 54 (2.13) 71 (2.80)
www.northmanfp.com
Q 55 (2.17) 68 (2.68) 82 (3.23)
54
R 35 (1.38) 40 (1.57) 50 (1.97)
H 30 (1.18) 35 (1.38) 46 (1.81)
J 28 (1.10) 30 (1.18) 31 (1.22)
T U V W 19 (0.75) 8.8 (0.35) 14 (0.55) 8.6 (0.34) 19 (0.75) 11 (0.43) 17.5 (0.69) 10.8 (0.43) 22 (0.87) 13.5 (0.53) 21 (0.83) 1 (0.04)
FLOW CONTROLS RESTRICTORS DIMENSIONS TCV-T03/06/10-**
MODEL
A
B
C
D
E
F
G
H
J
L
TCV-T03 70 (2.76) 35 (1.38) 40 (1.57) 180 (7.08) 62.5 (2.46) 58 (2.28) 42 (1.65) 21 (0.82) 40 (1.57) 19 (0.75) TCV-T06 100 (3.94) 50 (1.97) 60 (2.36) 215 (8.46) 83 (3.27) 65 (2.56) 62 (2.44) 31 (1.22) 60 (2.36) 19 (0.75) TCV-T10 130 (5.12) 65 (2.56) 80 (3.15) 228 (8.98) 106 (4.17) 77 (3.03) 82 (3.23) 41 (1.61) 80 (3.15) 22 (0.87)
Northman
www.northmanfp.com
55 55
N M10 (3/8") M19 (3/4") M32 (1-1/4")
FLOW CONTROLS RESTRICTORS DIMENSIONS TV/TCV-G03/06 TV/TCV-G03: ISO 5781-AG-06-2-A TV/TCV-G06: ISO 5781-AH-08-2-A MODEL TV TCV
-3 -6 -3 -6
MODEL C TV/TCV-G03 90 (3.54) TV/TCV-G06 102(4.02)
A PORT
B PORT
CONTROL FLOW IN PORT
CONTROL FLOW OUT PORT
CONTROL FLOW IN PORT OR FREE FLOW OUT PORT
CONTROL FLOW OUT PORT OR FREE FLOW IN PORT
D 66.7(2.63) 79.4(3.13)
E 33.3(1.31) 39.7(1.56)
MODEL TV/TCV-G03 TV/TCV-G06
L 31(1.22) 36(1.42)
Northman
www.northmanfp.com
F 11.7(0.46) 11.3(0.44)
M 31(1.22) 37(1.46)
56
G 173(6.81) 203(7.99)
H 42.9(1.69) 60.3(2.37)
J 32(1.26) 36.5(1.44)
K 64(2.52) 79(3.11)
FLOW CONTROLS RESTRICTORS DIMENSIONS TV/TCV-G10
MODEL TV-G10 TCV-G10
Northman
-3 -6 -3 -6
A PORT
B PORT
CONTROL FLOW IN PORT
CONTROL FLOW OUT PORT
CONTROL FLOW IN PORT OR FREE FLOW OUT PORT
CONTROL FLOW OUT PORT OR FREE FLOW IN PORT
www.northmanfp.com
57 57
FLOW CONTROLS SUBPLATE
FEATURES
Model Code
Northman
www.northmanfp.com
58
FLOW CONTROLS RESTRICTORS DIMENSIONS
MODEL TVM-03 TVM-06 TVM-10
A B C 120 (4.72) 100 (3.94) 10 (0.39) 134 (5.28) 110 (4.33) 12 (0.47) 160 (6.30) 132 (5.20) 14 (0.55)
MODEL
K
L
TVM-03
30 (1.18)
30 (1.18)
25 (0.98) M10 (3/8")
TVM-06
32 (1.26)
35 (1.38)
32 (1.26) M19 (3/4")
TVM-10
34 (1.34)
46 (1.81)
50 (1.97)
Northman
M
D 45 (1.77) 54 (2.13) 71 (2.80)
www.northmanfp.com
E F G 15 (0.59) 60 (2.36) 40 (1.57) 16 (0.63) 82 (3.23) 58 (2.28) 21 (0.83) 100 (3.94) 72 (2.83)
P
M32 (11/4)"
59 59
a M8x15L (5/16"x0.6"L) M10x20L (3/8"x0.8"L) M12x35L (1/2"x1.4"L)
H 10 (0.39) 12 (0.47) 14 (0.55)
I 20 (0.79) 29 (1.14) 36 (1.42)
b
c
d
9 (0.35)
14 (0.55)
10 (0.39)
11 (0.43)
18 (0.71)
12 (0.47)
13 (0.51)
20 (0.79)
14 (0.55)
J 60 (2.36) 70 (2.76) 92 (3.62)
LIFT VALVE
FEATURES • It provides four functions in one integrated body-system relief, check, flow control and solenoid operated directional control feature which is particularly needed by whoever builds hydraulic lifters or uses single acting cylinder for hydraulic control mechanism.
Symbol
Model Code
Northman
www.northmanfp.com
60
LIFT VALVE SPECIFICATIONS MAX. OPERATING PRESSURE MAX. FLOW CAPACITY MAX. FREQUENCIES OF OPERATING MAX. TANK LINE BACK PRESSURE
210 KGF/CM2 (3000PSI) 20 LPM (5.3 GPM) 60 CPM 7 KGF/CM2 (100PSI)
SOLENOID RATINGS COIL DATA(14.7WATTS) SOLENOID COIL AC115 AC230 DC12 DC24
VOLTAGE AC115V/60HZ AC230/60HZ DC12 DC12
HOLDING CURRENT(A) 0.13 0.06 1.22 0.61
SOLENOID RATINGS UNIT: mm(inch) WEIGHT: 1.7 kgs (3.74 lbs)
Northman
www.northmanfp.com
61 61
PISTON TYPE PRESSURE SWITCH
FEATURES •A micro switch will activate when an adjustable pressure setting is reached. It will remain actuated until the pressure falls below the setting.
Symbol
Model Code
Northman
www.northmanfp.com
62
PISTON TYPE PRESSURE SWITCH SPECIFICATIONS Model
Pressure range BAR(PSI)
Adjustment range BAR(PSI)
Max. pressure BAR(PSI)
PS-35-* PS-70-* PS-150-* PS-230-* PS-420-*
35(500) 70(1000) 150(2200) 230(3300) 420(6600)
7-35(100-500) 10-70(150-1000) 30-150(420-2200) 50-230(700-3300) 90-420(1300-6000)
210(3000) 210(3000) 210(3000) 350(5000) 500(7250)
General
Electric data
Mineral oil-based hydraulic fluids, Flame retardant Liquids (HFA, HFB, HFC).
Fluid
Fluid temperatures -30°C~ +110°C (-22°F~+22°F) Viscosity range 10-800 cSt (50-3700 SSU) Fluid cleanliness Switching repeatability Switching rate
Max. permissible oil contamination to NAS 1638 class 9,recommend achieved with filter β10 ≥75 Within 1% of Max. pressure 60 times/min
www.northmanfp.com
According to ISO 4400
Wire size
1.5 mm2 250V.5A 30V.5A 0.8 kg
Contact rating
SWITCHING HYSTERESIS DIAGRAM
Northman
Electrical connections
63 63
Mass
AC DC
PISTON TYPE PRESSURE SWITCH ELECTRICAL CONNECTION SYMBOL
DIMENSIONS
Northman
www.northmanfp.com
UNIT: mm(inch) WEIGHT : 1kgs(2.2lbs)
64
Northman
www.northmanfp.com
65 65