Make the most of your energy

Page 1

Make the most of your energy

Energy Efficiency Solutions guide


Became real Energy Efficiency specialist Visit our web site and lern more!

www.schneider-electric.com


We invite you to discover Energy Efficiency

Contents Why join Energy Efficiency? All committed to Energy Efficiency

Page 5

Distributor and installer: Key pieces in the Detection of Energy Savings

Page 6

Energy savings Power Industry

Page 7

How to evaluate the benefits for users, owners, and occupants?

Page 8

We target the best efficient solutions For residencial

Page 12

For buildings

Page 24

For industry

Page 54

Practical examples of Schneider Electric Energy Efficiency solutions

Page 66

Let’s join now the Energy Efficiency!

Page 120


Develop a common attitude

4


All committed to

Energy Efficiency Companies already participate in this challenge by making their products more sustainable from the moment of their creation, manufacturing, distribution, life cycle and also, thinking about its later recycling. At the same time we implement renewable sources of energy in production plants, which will lead us to a medium-term sustainability action. In a short term we need to invest in the demand, being more efficient in its use, as well as its maintenance and upkeep.

Consultancy and Measurement

Cycle of Continuous Improvement in Energy Efficiency Passive Energy Efficiency

Establish bases Low consumption devices Insulating material Correction of power factor

Active Energy Efficiency

Optimize through automation and control Building Management Solutions Industrial control solutions Motor control solutions Lighting control solutions Intelligent home solutions ‌

Monitor, Maintain, optimize Measurement systems and devices, monitoring services, high‑level software for the analysis of Energy Efficiency

5


Distributor and installer: Key pieces in the

Detection of Energy Savings The installer, being the one who knows the systems and their daily contact with the customer, is the one who detects possible Energy Efficiency savings in order to provide appropriate solutions. All systems, in terms of its use and operation, evolve with the flow of time, just like the manufacturers; evolve with new products that cover new necessities. This vision is the vision, that the installers, with the help of the distributor, offer to the market, making out of the today’s’ systems, the systems of the future, developable, economic and sustainable. For the detection of possible energy savings, it is very important to try to find the advice of the installer and of the distributor, so that they can analyze energy balances, the capacities of the systems and then identify short and medium-term energy savings. This will give us the answer, saying HOW and WHEN to act.

up to

energy saving Our range of products

Professional consultancy of your distributor and installer

6


Energy savings

Power Industry It is necessary to improve the supply, Work on the demand is obligatory now!

Energy Transformation

Energy Distribution

Coal 300 units

105 units

100 units saved in the consumption

100 units

300 units saved in energy production plant

7


How to evaluate the benefits for users, owners, and occupants? The proof by the examples! 50%

up to

ving gy sa ener

Example Control of pumps and fans in building or industry

Motor control with Variable Speed drives In a conventional pumping and ventilation installation, the electric motor is directly supplied by the line supply and runs at its rated speed. With a drive placed between the circuit breaker and motor the saving in electricity cost could reach from 15% and 50% depending on the installation. The return on the investment is usually very quick, between 9 and 24 months. Q Traditional control: 80% of nominal flux A 95% of nominal power

100% 80%

ontrol by a variable speed drive: C 80% of the flux A 50% of nominal power Evaluate your saving and your payback with our Eco8 software!

50%

60% 40% 20% 0%

20%

40%

60%

80%

100%

Measuring system: potential of saving up to 10% energy saving Example An industrial building (source: Gimelec "Efficacité Energétique April 2008")

Q Yearly electrical consumption: 100 MWh QA nnual cost: 120 k€ QE nergy saving target: 10% Implementation of a metering and monitoring solution with power meters, remote monitoring and power monitoring software. Q Investment: 11 k€

8

After report analysis and action implementation, the user has saved 14.4 k€ of his electricity bill that represent 45 days of consumption for production.


Lighting control allows up to 30% savings

Example 1 Potential saving on useless lighting and forgetting lighting-off (source: Cardonnel consultant)

Example 2 Control solution and consumption reduction (source: French Lighting association)

Lighting consumes 14% of all electricity within Europe and 19% of all electricity in the world (source IEA-International Energy Agency). Switching the older lighting to energy saving lighting is a first step that must be completed by the use of efficient devices that will switch-on and switch-off lights when it is necessary and will adapt it according to occupancy and/or brightness.

Type of building

Potential saving

Areas

School

25 to 30%

class rooms, resting areas… lobbies…

Offices

up to 42%

Hospital

18%

rooms

Hotel

20%

rooms, restaurant, lobby

Control solution

Saving

Yearly consumption (kWh/m2)

Manual switch

analyzing basis

19.5

Programmable time switch

10%

15.2

Presence detection

20%

13.2

Dimmers with brightness detection

29%

12

Brightness detection and presence detection

43%

9.6

Power quality and reduction of losses: up to 10 % Analysis: Q Power supply via a 1000 kVAR transformer, 0.8 power factor. Q Reactive energy invoiced: 10% of the total invoice amount.

Solution installed: A 250 kVAR Varset capacitor bank with detuned reactor and maintained the power factor above the re-invoicing limit (0.95), i.e.: Q -10% on the invoice, Q +15% extra available power.

0.82

15 kVAR capacitor banks disconnection

0.84 0.86

Cosphi [1]

Example Enable a bank to no longer pay for reactive energy and to increase the real available power

3 kVAR capacitor banks disconnection

0.88 0.90 0.92 0.94 0.96 0.98 1.00 -0.98 -0.96 26.12

26.18

27.00

27.00

27.12 712 12

day.time

9


Energy

Efficiency

Residential Sector Page 12

10

> Block of flats

Solutions

Buildings Sector

Page 24 > Offices Page 28 > Hotels Page 38 > C ommercial premises and restaurants Page 46 > Schools


for different markets and usage

Industry Sector Page 54 Page 58

> Common solutions > Specific solutions

50%

up to

saving energy

11


Residential sector

Block of flats Solutions in the following areas of application, in order to reach 40% of Energy Efficiency.

3 4

2 1

12

5


1

Management of the ventilation and presence in the parking

14

Variable speed drive Altivar and Argus Motion detectors.

2 Automatic lighting in common zones: Passages, stair cases, elevators...

16

Argus Motion detectors

3 Community Electric Panel

18

4 Automatic management

20

5 Intelligent management

22

Central Measurement Unit PowerLogic, surge arrester Quick PRD, presence detectors by Argus and differential switches REDs.

Argus Motion detectors, dimmers Unica, thermostat programmer Unica or elegance, radiofrequency solutions by Unica and elegance.

KNX-Dali de Schneider Electric and GSM module or automation Internet.

And also...

Control of the lighting in the outside areas of the hotel and watering of the garden

30

Twilight switch IC2000, variable speed drive Altivar, time switch IHP and Central Measurement Unit PM700.

13


> Parking Management of the ventilation and presence in the parking Willing to improve your neighbors’ comfort?

Installer’s efficient recommendation:

Fumes extraction from the parking generates noise that may be bothering for the neighbors of the plot.

How to reduce the noise coming from the ventilation? We suggest reducing decibels by regulating the operation of the motor, start-up and speed. With Altivar variable speed drive we can manage the speed of the ventilator at the start-up and during its operation. Moreover you can control the drive according to the volume of CO2 by means of specific sensors.

Turning light on and off does not satisfy the necessities of the users: – Usually there are few light switches and they are incorrectly distributed. – When switching the light, all lights in the parking are turned on. – Light may remain on.

The installer verifies the ventilation circuit and detects that there is no device that regulates ventilators. Every time ventilators start to operate at 100% of its power, they make bothering noise to the neighbors.

Read more about related application on page 78 How to manage lighting? The installer recommends controlling the activation of lighting by zones by means of Argus Motion detectors. The system assures the correct turning on of the lamps always when necessary.

Read more about related application on page 80, 88

Benefits For the owner of the system: We manage to correctly extract fumes, reducing noise generated by the ventilators. With regard to Energy Efficiency: By carrying out the control of the inverter according to the volume of CO, it is possible

to optimize the power consumption of your installation. By making the lighting system automatic, we manage to control the lighting necessities of the users of the parking.

14


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

Parking needs to comply with the minimum emergency lighting standards required by CTE and ITC-BT-29 of REBT. It’s vital to comply with the specific standard of the ventilation of premises that are especially endangered with fire hazard.

Products involved in this solution:

Variable speed drive Altivar 21

Management of the ventilation and presence in the parking

Factories with the necessity of ventilation, ventilation of fields.

Motion detector Argus 360

15


Residential Sector > Common shared zones Automatic lighting in common zones: corridors, staircases, elevators... Have you thought of having a more comfortable and safe staircase? It is not necessary that all lights in the whole stair case are on, when switching any light switch. It is not comfortable to switch the light when you arrive with your hands full of things.

Installer’s efficient recommendation: The community wants to modernize its shared installations and make them more comfortable for the neighbors and provide correct light at the right moment. The installer recommends to make the lighting of the building automatic and treat each zone as and independent and optimized one. How can we increase the comfort of the neighbors? We know it is not necessary to turn on all the lights in the staircase when someone switches the light. With Argus motion detectors, without the necessity to look for the device and switch the light, lights will be activated on such level where people are detected, enabling intelligent power consumption.

Read more about related application on page 80, 88, 96, 98

Benefits For the owner of the system:

We manage to modernize and improve the operation of our installation. We improve the comfort of the neighbors, by automatic lighting activation.

With regard to Energy Efficiency:

Reasonable and efficient use of electric energy used to illuminate staircase and landings, because only necessary lights are turned on at the moment. Reduce the community’s invoice for the power consumption.

16


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level A

saving energy

Inefficient

Remember...

It needs to comply with minimum emergency lighting required by CTE and ITC‑BT-29 of REBT.

Products involved in this solution:

Motion detector Argus 220

20%

up to

Motion detector Argus empotrable

Automatic lighting in common zones: corridors, staircases, elevators...

Passage zones and shared zones such as corridors, vestibules with elevators and staircases... in hotels, hospitals, offices, schools, public and industrial buildings.

Motion detector Unica

17


> Technical community installation Community Electric Panel

Can you imagine to have the community safe and under control? The aim is to reduce the bills for energy without reducing the comfort. Electrical discharge caused by thunders or manipulation are dangerous to household appliances and electronic devices. We want to have the biggest services continuity possible, especially in elevator and in the parking area..

Installer’s efficient recommendation: Bills for electric energy are very high ad we do not actually know the reason why. By having ME4 power meter you will be able to read the consumption of electric energy of different installations in the building, which will enable you to act in such areas where the consumption is excessive. There is a storm and due to electric discharges various receivers are destroyed. Provide in the community’s general electric panel, surge arrester Quick PRD in order to protect all electronic and electric devices. This device has automatic disconnecting device to assure bigger continuity of the services. Lights in the maintenance area sometimes stay on. By means of a presence detector by Argus we assure the activation of lights only when someone is in the area.

Read more about related application on page 122 By electrical discharge, caused by a storm, the elevator does not work because differential switch was activated. Place differential switches REDs to assure major continuity of the service of the elevator.

Benefits For the owner of the system:

The continuity of the service will increase in common shared zones, which will contribute to bigger comfort. The installation will be protected, which will exclude significant damages to the receivers in different zones.

In terms of Energy Efficiency:

Simply, with the supervision and control of the power consumption of the installation, it’s possible to save up to 10%.

18


Solution may be also applied in:

Community electric panel

Technical installation in the sector of services and in industry.

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

10%

up to

saving energy

Inefficient

Remember...

To be efficient in the management of technical alarms (fire alarms, water and gas leakages). In case the flat was further than 30 meters from the principal electric panel, where Quick PRD is installed, a new limiter should be installed in the electric panel of the said flat. For your safety, you should have highly secure cables “free of halogens” that will not propagate fire with a much reduced gas emission.

Products involved in this solution:

Differential switch REDs

Surge arrester Quick PRD

Presence detector Argus

Power meter ME4zrt

19


> Housing Automatic management

Willing to control your home automatically?

We spend a lot on heating and air conditioning and we do not make use of the sun. We would like to make the best use of the natural source of light, avoiding direct sunrays in summer. Sometimes we leave lights at home on.

Efficient installer’s recommendation: We want to make the utmost use of the sunlight in winter and not let heat out in the summer. With the elegance shades control device, we can program the schedule of opening and closing automatic shades. Moreover, with the elegance light sensor we can pull the shades depending on the brightness outside. We want to regulate or adjust the brightness level according to your needs. With Unica regulators, you will be able to control the lighting of your room or lounge, creating the right atmosphere during your stay, and at the same, time reduce the power consumption. We want to adjust air conditioning to our hourly habits. We can easily do it automatically with the weekly programmable thermostat Unica or elegance. Also available for under floor heating. We want to enrich our electrical system in the fastest and cleanest way. We can install new regulators, shades push buttons, and time-controlled programmable weekly thermostats, without the necessity of laying new lines of electrical wiring. All these applications are possible thanks to radiofrequency solutions such as Unica and elegance.

Read more about related application on page 96, 112

Benefits For the owner of the system:

You will be able to automatically manage the lighting, temperature, awnings, and shades, increasing the comfort of your house.

With regard to Energy Efficiency:

You will save up to 35% with the automation of all the functions.

20


The solution may be also applied in:

Automatic management

The solution may be also applied in hotel lounges and in restaurants in the table areas.

Solutions necessary to obtain Energy Efficiency level

level

Efficient

A

35%

up to

saving energy

Inefficient

Remember...

You can listen to the radio anywhere in your house, thanks to the digital sound broadcasting system by Unica. Emergency lighting is always useful in case of a power outage. Protect your electronic devices with the surge protector and automatic switches against false alarms due to storms. Install water saving system in all faucets and all flush toilets.

Products involved in this solution:

Shades Control System elegance

Thermostat elegance

Regulator Unica

21


Sector Residencial > Housing Intelligent management

If your car is intelligent... Why not your house be intelligent? We want a single intelligent system to manage our home. We want to have an intelligent solution that will ensure us in the future and the possibility to integrate and add new features with the possibility to modify current problems. We want a secure system against failure. We would like to control various devices in our home by means of Inmóvil or internet.

Efficient installer’s recommendation: We want to have an intelligent house that will manage the functions of our house. KNX system gives us all advantages to be able to manage the functions of our home in a simple and powerful way. We want our home automation system not to become outdated and that it gives us the possibility to add new features that we might need tomorrow. Thanks to KNX system by Schneider Electric, you will be able to add and control any product compatible with KNX communication protocol. Moreover, this 100% flexible system, allows you to change the configuration of all controllers of your system. This means that you will be able to change a feature in one light switch, so that it works as shades push-button. We do not want all our system to stop working due to an error or failure. KNX system by Schneider Electric is a powerful system that prevents failures. In the event that an error in the device occurred, the system will keep operating smoothly. We want to be able to control our home through internet or mobile telephone network. You will be able to control the temperature in your house, the lighting, pulling the shades up or down... in a remote way by GSM mobile system or through internet.

Benefits

Read more about related application on page 68, 70

The owner of the system:

With the KNX system by Schneider Electric, your house will have the maximum comfort and safety level. You will have a system without limits, flexible and developable, always that you may need new features to be added.

With regard to Energy Efficiency:

AYou will save up to 35% energy with the automation of all the processes. You will have a system without limits, flexible and developable always that you may need new features to be added.

22


The solution may be also applied in:

Intelligent management

Small buildings, Hotels, schools...

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

35%

up to

saving energy

Inefficient

Remember...

With this KNX system, you will also have the possibility to create different light scenes within the same room, library, offices, or rooms. It can also be used to stimulate your presence, for safety reasons. Emergency lighting will always be useful in case or power outage. Protect your house against technical alarms and be able to detect, on time, water and gas leakages, as well as fires and receive a SMS notification on your mobile phone. Protect your electronic devices with the surge protector and automatic switches against false alarms due to storms.

Products involved in this solution:

Multifunction pushbutton KNX

Motion detector KNX

Actuator/sensor Fan Coil KNX

23


Buildings Sector

Offices Our knowledge on the distribution and automation of energy offers up to 30% in energy savings in office buildings.

3

1

2

24


1

Intelligent Home System

Features module KNX: Thermostat, Push-buttones plus, Motion detector, magnetic window contactors, Actuator/sensor Fan Coil.

24

And also...

Management of the air conditioning and presence in the parking 20 Altivar variable speed drive and Argus movement detectors.

Control of outdoor lighting and watering of a garden

40

Management of air conditioning and lighting in reception and lounges

42

Twilight switch IC2000, variable speed drive Altivar, Time switch IHP and Measuring Central Unit PM700.

KNX system by Schneider Electric.

Make lighting in corridors, staircases, and toilets automatic

44

Motion detector Argus and Twilight detector.

Consumption measurement and energy management 68 Automatic switch Compact NSX, overvoltage limitersQuick PRD and capacitor bank with detuned reactor Varset SAH

25


Buildings Sector > Offices > Offices, lounges and open space Building Automation System

Did you know that the satisfaction of your employees increases the loyalty of your customers?

Efficient installer’s recommendation:

All the lights in room are always turned on.

If the window is open, I do not want to waste energy. We can control the air conditioning system or fan coil by installing contacts on windows and integrating them into the KNX system by Schneider Electric, which will disconnect the air conditioning when it detects that one of the windows is open.

Natural source of light that enters through the windows is not made use of. If the window is open, air conditioning should switch off. The sun can dazzle, when working on the computer.

I want to maximize the natural light coming through the windows of the office. Thanks to KNX-Dali Schneider Electric system, we constantly regulate the lighting of different independent zones, in terms of natural light, and the level of light needed in the work area.

I want my shades to act in an intelligent way. We can combine different solutions for our shades to act in the desired way. We may open or close them via time schedule, or according to the source of natural light. Can I create different scenes that will control various systems of the room? You can create as many scenes as you want. With the KNX system from Schneider Electric, you can close the shades, attenuate the light in the room, and roll down the projector screen by simply pressing a button.

Benefits

Read more about related application on page 68, 70

For the owner of the system:

Everything under control. No need to be aware of the lighting or the shades. The system is automatically controlled. Your employees will have the best working conditions to do their best at work. Your office will have a distinctive quality and image that will be given to the customers With KNX you will have a building automation system capable of controlling all devices.

For the employees:

The working day will be much nicer and you will receive a higher perceived value by the company.

With regard to Energy Efficiency:

With the automation of all processes, you will save up to 30% on energy.

26


The solution may also be applied in:

Building Automation System

Luxury homes, day centers, hotels‌

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

It is CTE requirement to adjust the lighting, depending on the amount of natural light outside. Thanks to Schneider Electric KNX system, we can achieve it. Remember that it is mandatory to have adequate emergency signaling system and fire detection system. Protect your electrical equipment with a Quick PRD against overvoltage (lightning, power surges, etc.).

Products involved in this solution:

Multifunctional button KNX

Motion detector KNX

Actuator/Controller Fan Coil KNX 27


Buildings Sector

Hotels When applying our suggestions and proposals, power consumption in a hotel may be reduced up to 30%.

4 3

1 2

28


outdoor lighting and the 1 Control watering of a garden

Twilight switch IC2000, variable speed drive Altivar, Time switch IHP and Measuring Central Unit PM700.

30

2 Management of air conditioning and lighting in reception and lounges

KNX system by Schneider Electric: push-button and thermostat elegance with touch screen IP.

3 Make lighting in corridors, staircases, and toilets automatic

Motion and twilight detector Argus. Time switch IHP.

4 Manage the lighting and the climate in the room

KNX system Schneider Electric: Presence push-button, Motion detector and Actuator/sensor Fan Coil.

32

34

36

And also...

Management of the air conditioning and presence in a parking

20

Altivar variable speed drive and Argus movement detectors.

Consumption measurement and energy management

68

Automatic switch Compact NSX, overvoltage limiters Quick PRD and capacitor bank with detuned reactor Varset SAH

29


Buildings Sector > Hotels > Outside areas of the hotel Control of the lighting in the outside areas of the hotel and watering of the garden Do you want your guests to enjoy the outdoor spaces of the hotel?

Efficient installer’s recommendation: The illumination of the facade of the building and the light sign remain unnecessarily on during daylight. The installation of a Twilight IC2000 switch, allows automatic switching on and off lighting, depending on natural light.

Read more about related application on page 110 The gardens and exterior lighting of the building needs to strengthen the hotel’s charm. – Gardens need special attention at the time of watering. – The lighting of the gardens, as the sign of the hotel, has both: a functional and aesthetic purpose. – The outdoor pool has to be open from May to October, in the optimum conditions of comfort for guests.

The pool needs to have a water filter while open to the public. Automatic management of the pool by Time IHP, two output switches can control the filter pump and the water supply valve of the footbaths. To regulate the pumping of necessary filtered pool water, install Altivar variable speed drive to achieve optimum flow, and thereby, reduce electricity bill.

Read more about related application on page 116 The gardens maintenance staff are not present every day. By installing a two-channel Time IHP switch, you can independently control garden watering and lighting, activate or deactivate these services according to schedules and seasons.

Read more about related application on page 108

Benefits

These facilities have a high annual consumption reflected in the electricity bill. By installing PM700 Central Unit Measuring, we can measure the annual consumption, the activation and deactivation times, as well as assess active and reactive energy consumed per hour. With this information, we can act appropriately, in order to improve the efficiency of our facility.

For the owner of the system:

Improves the exterior image of the hotel to attract more clients. Improves guests’ comfort.

With regard to Energy Efficiency:

Excellent efficiency in lighting automation, saving up to 15% in electricity bill. Efficient regulation of water pumped into the pool, saving up to 25% of energy. Monitoring of electricity consumption that will provide up to 10% savings.

30


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

In case of storms or humidity, the first one that is activated is the circuit breaker. A REDs can reconnect the installation only if the defect has disappeared, ensuring the safety of persons and of the system. Furthermore, protect your equipment with PRD voltage limiters. Rainwater tanks can help reduce water consumption for garden-watering purposes

Products involved in this solution:

Twilight switch IC2000

Photocell

Time switch IHP

Variable speed drive Measuring Central Unit Altivar 12 PowerLogic PM700

Control of the lighting in the outside areas of the hotel and watering of the garden

External lighting of monuments. Swimming pools and gardens.

31


Buildings Sector > Hotels > Reception and Halls Management of air conditioning and lighting

Would you like to customize the ambience of the guest rooms and adapt it to their needs? Our aim is to obtain the best performance from all hotel areas. The rooms should be universal: today it could be used as a dining room, tomorrow as a conference room and the day after, as an exhibition hall. The customer should find spaces adapted to his or her needs.

Efficient installer’s recommendation: The hotel manager wants all hotel rooms and lounges to offer the maximum flexibility to meet the customers’ needs. How can I get my hotel to be flexible? Thanks to the KNX system by Schneider Electric, you can make your facility 100% flexible. The communication bus allows us to configure our installation, as we want, without the necessity for further construction or designing new cabling structures What advantages in management does KNX offer me? The KNX system allows us to control the lighting, adjusting it to our requirements. We can centralize, regulate, and control the lighting from several points, making all the scenes we want to program. What else does the KNX offer? The KNX system allows us to control much more than just lighting. We can easily manage all devices and services that are connected to the KNX bus. Building management, automatic adjustment hours and conditional regulation, constant regulation of lighting... everything is possible with KNX.

Read more about related application on page 68, 70

Benefits For the owner of the system:

By making the utmost use of your facilities, you can obtain much more performance from your spaces You will be able to get more customers with flexible facilities that meet their needs. With KNX you can develop your installation and modify the control and the management of the different elements.

With regard to Energy Efficiency:

You can make light and air conditioning systems automatic, and make them more efficient at the same time. By implementing a KNX building automation system from Schneider Electric, you may save up to 35% energy.

32


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

level

Efficient

A

35%

up to

saving energy

Inefficient

Remember...

The KNX system is not a proprietary system belonging to a certain manufacturer. Therefore, when launched, you have the possibility to expand its features with product from over 150 companies that make mutually compatible elements.

Management of air conditioning and lighting

Public buildings, offices, luxury homes…

Products involved in this solution:

Push-button elegance KNX

Thermostat KNX

Touch screen IP

33


Buildings Sector > Hotels > Common shared zones Make lighting in corridors, staircases, and toilets automatic What if the common shared areas were more comfortable for the guests? Toilets are common areas for all guests and must be properly air‑conditioned. Common areas should be well lit and ventilated. The lighting should be connected at the precise moment when necessary

Efficient installer’s recommendation: A customer walks into the bathroom and when leaving, leaves the lights on. With Argus motion detector, lights are switched on or off when a guest enters or leaves the area. The bathroom ventilation system is permanently connected. The second independent Argus Motion detector exit is used to turn off the exhaust a few minutes after the sensor detected that the guest left. In the common shared areas with natural source of light, we waste energy by keeping the lights on. With Argus twilight detector, we can regulate the threshold of power in the common shared areas, according to the amount of natural light.

Read more about related application on page 80, 88, 108

A stay with the lights on without people inside it, is a useless waste.

Benefits For the owner of the system:

Give maximum comfort to the clients and considerably reduce the electricity bill.

With regard to Energy Efficiency:

Maintain appropriate lighting levels in all areas saving up to 20%. Provide toilets with a proper ventilation system.

34


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

20%

up to

saving energy

Inefficient

Remember...

To be efficient in the management of technical alarms (fire, water leakages...). It is advisable to install water-saving systems such as automatic faucets with infrared sensors.

Make lighting in corridors, staircases, and toilets automatic

Common shared zones and toilets of any public space, such as restaurants and offices.

Products involved in this solution:

Motion detector Argus

Twilight detector Argus

Time switch IHP

35


Buildings Sector > Hotels > Rooms Manage lighting and atmosphere

What if your guests felt like at home? Difficulty to customize all services, such as air conditioning, shades, and lighting, according to preset schedules or guests’ wishes. The necessity of having a centralized system of lighting, air conditioning, and ventilation working, while guests are not in the room. It is not possible to know the status of the installation from the reception of the hotel.

Efficient installer’s recommendation: It is necessary to maximize the use of natural light. It is possible to achieve it by lighting sectors within the room, depending on natural light. The KNX bus can automatically control it. If the window is open, no energy should be wasted. This is possible to achieve by means of KNX system by Schneider Electric. It is only necessary to introduce to the system sensors that will detect the opening and closing the windows to shut down the air conditioning system. Wake up at dawn with daylight. By installing the automatic shades module integrated into the KNX system by Schneider Electric, the guest can select the time of opening and closing of shades via a user display.

All natural light coming through the windows is not made use of.

Read more about related application on page 68, 70

If someone opens the windows, air conditioning should switch off.

Benefits For the owner of the system:

You will achieve a differentiating element in your hotel. Avoid unnecessary visits of maintenance staff and detect possible failures. No energy is wasted by improper use of the facility, reducing the power consumption to meet the needs of customers.

For your clients:

Your customers will receive personalized services, as if they were at home These special services will enhance the overall customer satisfaction and his/her loyalty towards the hotel.

With regard to Energy Efficiency:

A KNX integrated management system allows saving energy on lighting and air conditioning by up to 30%. These savings are reflected in reducing the electricity bill and in your environmental contribution.

36


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level A

30%

up to

saving energy

Inefficient

Remember...

Manage lighting and the atmosphere

Libraries, day centers, restaurants, hospitals, luxury homes. Shops and shopping centers.

To be efficient in the management of technical alarms (fire, water leaks ...) protect the receivers with Quick PRD overvoltage limiters. Solar equipment for water heating are required by the Technical Building Code and contribute to significant energy saving.

Products involved in this solution:

Multifunction push-button Motion detector KNX KNX

Actuator/sensor Fan Coil KNX

37


Buildings Sector

Commercial premises and restaurants 30% of savings with optimum energy management.

4

2

3 1

38


moods with the use of lighting 1 Create Multifunctional switches Ikeos and twilight switches IC2000 along with

40

Photocells.

2 Customize the lighting and air conditioning in a restaurant

Tele-inverters STD, Altivar variable speed drive, and Time switch IHP.

42

3 Fumes extraction and air conditioning in the kitchen

Variable speed drive Altivar, Time switch IHP and Weekly programmable thermostat programmable Unica.

44

And also...

Management of the air conditioning and presence in a parking

20

Control de la outdoor lighting and watering of a garden

40

Management of air conditioning and lighting in reception and lounges

42

Make lighting in corridors, staircases and toilets automatic

44

Altivar variable speed drive and Argus movement detectors.

Twilight switch IC2000, variable speed drive Altivar, Time switch IHP Measuring Central Unit PM700.

KNX system by Schneider Electric.

Motion detector Argus and Twilight detector.

Consumption measurement and energy management 68 Automatic switch Compact NSX, overvoltage limiters Quick PRD and capacitor bank with detuned reactor Varset SAH

39


Commercial premises Create moods with the use of lighting

Can you increase the customer attraction and the profitability of your facility at the same time? Selling and serving customers is the mission of the employees, but this does not save energy because they cannot manage properly the interior and exterior lighting of the shop. We need to attract our customers’ attention, both outside and inside the shop. We want to use only necessary energy.

Efficient installer’s recommendation: By emphasizing the most important sales spaces and the different needs of each of them, the installer will recommend Ikeos automation system. How can I increase the visibility of my business premises? To turn on the lighted sign, you can connect to one of the Ikeos inputs IC2000; a photocell will be connected when necessary. We can even perform intermittent lighting to increase its visibility.

Read more about related application on page 110 Can I stop worrying about turning off the lights in my warehouse? To turn the lights off automatically, we can use the timer function provided by Ikeos. You will not worry about leaving the light on, because as we leave with our hands full, as the light will turn off automatically.

Read more about related application on page 106 Can I choose when I want the lights to stay on, on my shop window? You can define periods when you want the lights to be switched on, on the shop window, by means of an annual Ikeos Programmable Time Switch. This allows you to define what time and what days the light should stay on. The same function can automatically turn on and off the light and air conditioning in various areas of the store that remain open to the public: changing rooms, display area, and warehouse, preventing that the light is unnecessarily turned on during all night.

Benefits For the owner of the system:

The lighting will cease to be one of your daily tasks, giving you more time to devote to your business and your customers. You will obtain an image of your business that will be more attractive to your customers.

With regard to Energy Efficiency:

Your electricity bill will no more come as a surprise for you, as controlling when the lights turn on and off, will automatically monitor, and reduce electricity costs, increasing your profitability.

40


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

25%

up to

saving energy

Inefficient

Remember...

Create moods with the use of lighting

Lighting customer zones and bars, restaurants, supermarkets and cinemas.

For larger installations where a customer-tailored solution is required, it can be done with the Zelio Logic programming and remote control. Checking temperature in a room with a thermostat and maintaining it on a constant level significantly contributes to saving energy. The installation of motors in awnings and shades, efficiently contributes to the regulation of air conditioning.

Products involved in this solution:

Multifunctional time switch Ikeos

Twilight switch IC2000

Photocell

41


Buildings Sector > Restaurants > Table area Customize lighting and air conditioning

Would you like your customers to come back more often? Common shared areas require warm and customized atmosphere for your customers. Often the air conditioning operates at high level with low performance. It is logical that there are more important things to think about, than to go hours before to connect air conditioning.

Efficient installer’s recommendation: It is possible that for good lighting, you are spending more energy than necessary. By installing STD tele-inverters, it is possible to create scenes and decrease or increase the power of the light. You can create different lighting zones controlled by a tele-inverter: bar area with additional low-energy light, and another area, the restaurant is lit with incandescent lights to regulate their intensity through the push-button. With a long push-movement, the light becomes less or more intense.

Read more about related application on page 92 We want to prevent the ventilation to operate at peak performance when the room is not full. With the Altivar variable speed drive, you can control the speed of ventilation, based on occupancy of the room.

Read more about related application on page 78 We maintain comfortable environment for our clients, without having to worry about turning the air conditioning on and off. Using IHP Time Switch ensures the activation or deactivation of air-conditioning and ventilation, avoiding situations that they are on, when the restaurant is closed.

Read more about related application on page 108

Benefits For the owner of the system:

We will make the client’s stay more pleasant and comfortable by personalizing the environment. Let us make the lifetime of the installation longer, by making smooth stops and starts to avoid the problem of sudden stops.

With regard to Energy Efficiency

Control energy expenditure in three ways: - Decreasing power consumption on light through the tele-inverters. - Using variable speed drives saves up to 50% energy. - By controlling the switching on / off of air conditioning, we will avoid unnecessary power consumption.

42


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

Customize lighting and air conditioning

Libraries, halls of the hotels...

To be efficient in the management of technical alarms (fire, water leaks ...). (Fire, gas and water leakages) and protect your electrical equipment against overvoltage (lightning, power surges ...) with overvoltage limiters.

Products involved in this solution:

Digital tele-inverter STD

Variable speed drive Altivar 21

Time switch IHP

43


Buildings Sector > Restaurants > Kitchen Fumes extraction and air conditioning

What if we could improve the comfort and the performance of your kitchen? The space in the kitchen is small and usually very busy. Add to this, harsh working conditions, such as heat, smoke, odors... There are periods where the kitchen needs high performance or air conditioning and other moments, when such performance is not necessary. Of course, employees should concentrate on improving the quality of the culinary dishes, and not control air conditioning.

Efficient installer’s recommendation: Since the kitchen needs proper ventilation, it should conform to the periods when it is necessary. Therefore, when working in the kitchen does require the maximum performance, it is not necessary that the ventilation engine work at the top speed. Altivar variable speed drive efficiently manages the adjustment of extraction rate by reducing or increasing the speed according to the needs. The drive may connect to a centralized management system for buildings. In addition, with IP54 option, its reliability increases in harsh environment such as the kitchen. It is also possible to detect a fire and not stop the extraction of smoke while gas supply is cut. The demand for smoke extraction is managed using a digital IHP time switch to schedule the hours and days that the ventilation should be activated.

Read more about related application on page 78 If there is air conditioning, it must adapt to the schedules without the obligation of manual adjustments. With Unica weekly programmable thermostat, it is possible to define temperature that should be maintained and comfortable temperatures. This will avoid unnecessary consumption, by means of the automation of air conditioning that will adapt to our preferences.

Read more about related application on page 98

Benefits For the owner of the system:

The business will have a better performance with a better customer service, resulting from the improved working conditions and comfort for the kitchen staff. Extends the life of the installation and protects the motors, preventing the fan to run all the time at full capacity.

With regard to Energy Efficiency

Exhaust power consumption is reduced by 50% when operating at 80% of its efficiency. Scheduling of the air conditioning can save up to 30% by the automatic shutoff.

44


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

Fumes extraction and air conditioning

Ventilation and air conditioning of: fitness clubs, school halls, offices...

To be efficient in the management of technical alarms (fire, water leaks ...). (Fire, gas and water leakages) and protect your electrical equipment against overvoltage (lightning, power surges ...) with overvoltage limiters. The Fire Safety Regulations in buildings and regarding smoke extraction in industrial kitchens with specifications for filter duct fans and hoods.

Products involved in this solution:

Variable speed drive Altivar 21

Time switch IHP

Weekly programmable thermostat Unica

45


Buildings Sector

Schools Implementing Energy Efficiency measures can provide up to 30% savings.

3

46


1

Adapt ventilation to the schedule of the school and lighting in the classrooms 48 Motion detector Argus, Time switch IHP and variable speed drive Altivar 21.

2 Adjust the temperature and lighting according to the use of the gym

50

Variable speed drive Altivar 21, Time switch IHP and Twilight detector Argus.

3 Customize students’ comfort in the library

Variable speed drive Altivar, Time switch IHP and weekly programmable thermostat Unica.

52

And also...

Control of outdoor lighting and watering of the garden 40 Twilight detector IC2000, variable speed drive Altivar, Time switch IHP Central Measuring Unit PM700.

Automate lighting in the corridors, stair cases and bathrooms

44

Measurement of energy consumption and energy management

68

Motion detector Argus and Twilight detector.

Automatic switch Compact NSX, overvoltage limiters Quick PRD and capacitor bank with detuned reactor Varset SAH

47


Buildings Sector > Schools > Classrooms Adapt ventilation and lighting to the schedule of the school What if teachers can better teach their classes and students improve their grades? Students and teachers need to have the best conditions to make the utmost use of the lessons. The classrooms have no proper ventilation or lighting that would be adapted to their function.

Efficient installer’s recommendation: The lighting is too intense or not enough intense, depending on time of the day and seasons. Argus detector system turns the light on or off, depending on the natural light and the presence of the students.

Read more about related application on page 80, 88 The classrooms are enclosed spaces with a large number of people inside and correct air exchange is necessary. You can manage the ventilation in relation to the occupation of the classrooms and to the schedule defined by a programmable IHP switch. In addition, the use of Altivar 21 variable speed drive to control the fan speed, depending on the required flow, saves energy. Read more about related application on page 78, 108

Benefits For the owner of the system:

The improvement of working and learning conditions for teachers and students.

With regard to Energy Efficiency:

Significant savings in electricity bill as opposed to lighting and ventilation that is not automated.

48


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficien

level

A

30%

up to

saving energy

Inefficient

Remember...

To be efficient in the management of technical fire alarms as well as signs and emergency lighting. The classrooms in grammar schools must have a quantity of 300 lux complying with EN 12464-1.

Products involved in this solution:

Motion detector Argus

Time switch IHP

Adapt ventilation and lighting to the schedule of the school

Meeting rooms in office buildings or conference rooms in hotels.

Variable speed drive Altivar 21

49


Buildings Sector > Schools > Gym Adjust the temperature and lighting according to the needs Why waste the opportunity to save energy in your gym?

This is a system with very diverse zones (changing rooms, activity lounges…) Different energy management will be required in changing rooms, activity room, and a swimming pool. The user does not care about the power consumption in various installations. Moisture extractor in the showers runs continuously.

Read more about related application on page 98

Efficient installer’s recommendation: We must ensure that moisture in the showers does not reach too high levels. There are several methods; the most effective alternative in this case is to control the fan speed through an Altivar variable speed drive and a humidistat. The fan works at a speed that is adjusted to the degree of moisture, and therefore saves energy. In the multi-activity room, we need to manage the lighting and ventilation in an optimal way, according to occupation. With Argus detectors, we can turn on the lighting and the ventilation only when users are present in the room. We will also optimize the consumption of the ventilation engine with the implementation of an Altivar drive.

Read more about related application on page 78 For a long time during the day, there is enough natural light to illuminate the gym without having all the lights on. By Argus twilight detectors, we will manage the turning of lights on and off in order to make the best use of natural light. We can reach an integrated and centralized solution through a KNX solution. In the pool, we define the turning on and off of the air conditioning, ventilation and lighting according to a preset schedule of activities. Depending on your needs, with IHP time switch, we can define the activation of the air conditioning or ventilation, some time before the opening, as well as lighting, with the arrival of the personnel. We may also optimize the pumping of water with an Altivar drive that will provide bigger or smaller flow.

Benefits

Read more about related application on page 76, 78

For the owner of the system:

Your costs will be much more adapted to the lower power consumption and your service will be more tailored to the users’ needs. The lifecycle of your facilities will be longer, thanks to a smooth start, caused by the variable speed drive.

With regard to Energy Efficiency:

Significant energy saving of 30% with the use of presence detectors, and up to 50% with the use of inverters.

50


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

With Zelio Logic and a GSM modem, you can receive technical alarm messages on your mobile phone. If your system allows it, you can install photovoltaic panels to generate electricity, or a thermal plant to heat water for the system. Centralized facilities of air conditioning or ventilation of more than 10,000 mÂł / h must meet specific regulations regarding equipment characteristics.

Products involved in this solution:

Variable speed drive Altivar 21

Time switch IHP

Twilight detector Argus

Adjust the temperature and lighting according to the needs

First-aid-rooms, public sports facilities, private gyms, SPA centers.

51


Buildings Sector > Schools > Library Custom the level of comfort for the student

Did you know that better comfort equals to a better performance? We have a large space with lots of light during specific times of the day. We want to use natural light in areas that face the exterior side. We need quiet environment suitable for studying.

Efficient installer’s recommendation: The lighting is turned on in all areas regardless of the actual occupancy of the space. Argus presence detectors installed in strategic areas, ensure illumination only where needed, so it is possible to take advantage of natural light.

Read more about related application on page 80, 82, 88 File areas are usually aisles with bookshelves, and do not need to be permanently illuminated. At the beginning and the end of the aisle, install an Argus motion detector to turn on the light during the time of the book search. The reading area is usually situated in the area with more natural light. By installing IC2000 twilight detector with its photocell, we will activate the lights in the area, where the external light source is not enough.

Read more about related application on page 110 Avoid situations when the library is closed and the air conditioning is working. By means of IHP time switch, schedule the activation and deactivation of the air conditioning.

Read more about related application on page 76

Benefits For the owner of the system:

You will get more performance and comfort for library users.

With regard to Energy Efficiency:

Considerable savings in lighting and air conditioning ensuring that they are used only when necessary. We can get up to 20% savings with these solutions.

52


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

20%

up to

saving energy

Inefficient

Remember...

Be efficient in the management of technical alarms (fire, gas, and water leakages) and protect your electrical equipment against overvoltage (lightning, power surges ...) with surge protectors.

Custom the level of comfort for the student

Hotel common shared zones, warehouses, offices, public libraries...

Products involved in this solution:

Motion detector Argus

Time switch IHP

Motion detector Argus 220

Twilight detector IC2000

Photocell

53


Industry sector

Common solutions Solutions that help to save energy of up to 30%.

1

2

54


1

Measurement of energy consumption and energy management

56

Automatic switch Compact NSX, overvoltage limiters Quick PRD and capacitor bank with detuned reactor Varset SAH

And also...

Control of outdoor lighting

40

Twilight detector IC2000, Time switch IHP and Central Measuring Unit PM700.

55


Industry Sector > Common solutions > Technical system Measurement of energy consumption and energy management What if the consumption of you installation was in your hands?

Efficient installer’s recommendation:

The equipment has high consumption and the continuity of service is basically important.

We operate in the field of industry and want to parameterize the values of protections, so we have to go to the electrical board. With Modbus communication module, we manage to analyze the energy consumption, cost allocation, and analyze the quality of supply remotely, from the offices without having to go to that certain spot.

We have a continuous demand for increasing productivity. We need that equipment that is critical to the production be protected against electric shock caused by lightning or supply defects.

The electricity bill is very high and has many take-off points in different areas. Protecting your installation with the new Compact NSX range, with advanced control unit, you will be able to see the consumption of each line of the system, in order to detect excessive consumption.

Transitory surge, due to a storm or a manipulation of the network, can cause damage to the receivers. Install a Quick PRD surge arrester to protect all electrical and electronic equipment. This device incorporates an automatic shutdown to provide greater continuity of service. The lights in the technical rooms often remain turned on. Using Argus motion detector we ensure the turning on of light, only when required by the user. Any industry can have many engines that generate reactive power as well as harmonics in the installation. They prevent the increase of the power consumption and, this, the electricity bill. Placing Varset SAH capacitor bank with detuned reactor you can correct the generation of reactive power to reduce the electricity bill. You will also have your equipment protected against harmonic damages that occur in engines.

Benefits For the owner of the system:

Your business will improve its productivity through the reduction of failures:

With regard to Energy Efficiency:

A much more efficient use of energy. We will reduce the electricity bill up to 30% with the implementation of condenser batteries. In addition, supervision and monitoring of the installation power consumption contributes to a more efficient use of energy and contributes to a more conscious behavior, allowing to save up to 10%.

56


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

Efficient

level

A

30%

up to

saving energy

Inefficient

Remember...

Be efficient in the management of technical alarms (fire, gas, and water leakages) and ensure continuity of service with the range of REDs switches. The solar equipment for hot water is required by the Technical Building Code and contribute to significant energy saving.

Products involved in this solution:

Circuit breakers Compact NSX

Surge arrester Quick PRD

Motion detector Argus

Measurement of consumption and energy management

Technical system in a medium or large-sized sector of services.

Capacitor bank Varset SAH

57


Industry sector

Specific solutions Solutions tailored to each company to achieve 30% of savings.

58


1

Management of loads

2

Management of lighting in docks and picking areas

60

RelĂŠ Zelio Control, power suplly Phaseo and touch screen Magelis.

62

Motion detector Argus 360, Twilight detector IC2000 and Photocell.

3

Automation of conveyors

64

Programmable robot Twido, variable speed drive Altivar 312, button Harmony and contactors TeSys T.

59


Specific solutions > Workshops Management of loads

Why not intelligently manage the turning on and off, of the loads to reduce your bill? I am heavily penalized for exceeding the maximum contracted power or I have to contract a higher power than that what I need. If there is a voltage drop, I cannot give priority to certain areas of operation.

Efficient installer’s recommendation: How to reduce the contracted power without lowering the performance of my mains? It is possible to sequence start-up peaks of the systems or loads in such a way, that they are not added and that the resulting start-up peak, be much smaller. This may be achieved by installing a programmable Logic Zelio relay. As you have up to 10 outputs of up to 6 A, it is not necessary to place interface relays, and it is very practical for situations where the box space is limited. With 7 poles, it is possible to activate sequentially up to 10 different areas. If necessary, more Zelios in Ethernet may be connected in cascade, in order to incorporate as many zones as desired. For a more intuitive management, you can incorporate Magelis touch screen.

Read more about related application on page 120 If the network drops temporarily, I would like to try to maintain some of the facilities working. Zelio Logic Relay can be programmed to give priorities and to alleviate non-priority loads. The installing a Phaseo power supply, keeps critical parts of the installation in progress. As an advanced installation, it would be possible to establish different control areas, designating different groups of loads in each of them.

Benefits For the owner of the system:

Lengthen the lifecycle of the installation, as the sequential turning on and off, makes that transient voltage peaks are absorbed by other loads on the network.

With regard to Energy Efficiency:

Decrease your electricity bill, by reaching a lower contracted power.

60


The solution may be also applied in:

Management of loads

Hotels, hospitals, cinemas, restaurants, large warehouses, industrial workshops, offices...

Solutions necessary to obtain Energy Efficiency level

level

Efficient

A

10%

up to

saving energy

Inefficient

Remember...

In case of the activation of a fuse due to storms, humidity or false alarms, a RED can reconnect the installation only if the defect has disappeared, ensuring the safety of persons and of the installation and service continuity. In industrial premises, cables must not propagate fire and have limited smoke emission and reduced opacity.

Products involved in this solution:

Programmable relay Zelio Logic

Touch screen Magelis

Power supply Phaseo

61


Specific solutions > Logistics and Warehouse Management of lighting on docks and picking areas

Do you want to ensure proper illumination of the dock, only when needed? The docks and picking area are different large areas that do not require lighting 24 hours a day. Only when used, they must be properly lit to enable the preparation of material.

Efficient installer’s recommendation: The lighting stays on because it is often connected manually and the proper use of the facility depends on employees. It is possible that when closing the dock there are some lights that are switched on during all night. Employees are loaded with material and cannot comfortably operate the lights in different areas. We can strategically place Argus motion detectors in each work area, to light only the areas where work is performed. This is how we can create different areas with independent administration in order to optimize the use of energy. With Twilight IC2000 detector and the photoelectric cell, you can regulate the threshold of light in each area, depending on external light entering into the dock.

We do not always take advantage of natural light during the day.

Read more about related application on page 80, 110

Benefits For the owner of the system:

Improved working conditions through the automation of lighting… It may also lead to avoiding accidents.

With regard to Energy Efficiency:

Potential reduction in the electricity bill with energy saving of up to 15%.

62


The solution may also be applied in:

Solutions necessary to obtain Energy Efficiency level

level

Efficient

A

saving energy

Inefficient

Remember...

15%

up to

Install Primalum emergency signs provide safe lighting quantity in case of power outage.

Management of lighting on docks and picking areas

Trespass areas of occasional use in any building.

Products involved in this solution:

Motion detector Argus 360

Twilight detector IC2000

Photocell

63


Sector Industry > Specific solutions > Logistics and Warehouse Automation of conveyors

What if you consumed only the necessary energy? Some conveyors work even if there are no products on them. When the demand for production decreases, the speed of the conveyors and their power consumption remains at the same level of 100%.

Efficient installer’s recommendation: Start or stop the conveyor depending on whether there are products on it, or not: For small installations, or such of just one conveyor, it is necessary to connect OsiSense products sensors, directly to the coils of the TeSys contactors. If you wanted a more efficient solution, we would suggest you to install low consumption TeSys contactors. For medium-sized installations, or such with various conveyors, we could make a simple control with a Twido controler. It can capture all signals from OsiSense detectors and can synchronize the turning on/off of the conveyors. Reduce or increase the production rate, depending on the need: By installing Altivar variable speed drives, we can adjust the speed and the consumption, depending on the demand. We can do it by manually increasing or decreasing the speed, or with the orders issued by Twido controler. Signals power consumption can be reduced. We can achieve this using low power push buttons Harmony that also significantly increases its lifecycle.

Benefits For the owner of the system:

Proper automation will avoid premature wear of the material, and will also reduce machine stoppages due to failures and consequently, will increase its productivity. By reducing your electricity bill, you will reduce your production costs, using only the necessary amount of energy.

With regard to Energy Efficiency:

Low power TeSys contactors reduce your power consumption by 55%, when compared with traditional contactors.

64


The solution may also be applied in:

Interpact

Twido Multi 9

Solutions necessary to obtain Energy Efficiency levelQ2 GV2

Remember...

ny Preventa

level

Efficient

30%

up to

A

Automation of band conveyors

Loading docks, packaging machinery, supermarket band conveyor.

saving energy

Inefficient

Phaseo

Protect your industrial facility with a range of Preventa security products that ensure the protection and immediate stop in an emergency. This will help to meet the machines required standards. Be efficient in the management of technical alarms (fire, gas, and water KM1 leakages) TeSys Dand protect your electrical equipment against overvoltage (lightning, power surges ...) with surge protectors. In case of storms, humidity, or false alarms, the first thing to actuate is the circuit breaker. A REDs can reconnect the installation only if the defect has disappeared, ensuring the safety of persons and of the installation.

Products involved in this solution: Altivar 312

Harmony bajo consumo

Harmony bajo consumo Programmable controler Twido

Variable speed drive Altivar 312

Low-power led Harmony

OsiSense Detectors OsiSense

Contactors TeSys D

65


Practical examples

of Schneider Electric Energy Efficiency solutions

Sustained Energy Savings Measurement and monitoring

Customer commitment

Energy Efficiency needs a structured ­approach. Metering, remote ­monitoring and control provide information that helps customers to be aware of the role they play in energy savings and to keep sustained savings.


Content HVAC Control (Heating Ventilation Air Condition) Automate lighting, temperature and shutter control in office buildings Combine lighting, temperature and shutter control in office buildings Manage load shedding of your home electrical Installation Manage ventilation in hotel bathroom Manage water heating in public buildings Ensure effective operation of a cooling tower fan Lighting Control Automate lighting of a building hall Automate lighting of access to your home Automate public lighting according to sunrise and sunset Automate lighting of surroundings of a building Control lighting in classrooms Control office lighting locally Create restaurant mood lighting Ensure effective lighting of the entrance of a block of flats Manage automatic lighting by presence detection in home Manage automatic lighting in large areas with movement detectors Manage lighting in a garage Manage lighting in a hotel corridor Manage lighting in building stairways Manage lighting in various parts of a shop Monitor lighting time and manage the bells in a school Optimise hotel car park lighting Optimise room lighting through the use of dimmers Optimise shop-window lighting

Key EE product

Page

KNX

68

KNX, Argus

70

CDS RTC IHP Altivar 21

72 74 76 78

CDM Argus CDM

80 82

IC Astro IC 100 CDP ARGUS IHP STD 400, STD1000

84 86 88 90 92

MIN

94

CDM Unica

96

CDM Unica MIN MIN Unica Timer IKEOS IHP IC2000 Unica Dimmer IC2000P+

98 100 102 104 106 108 110 112 114

Motor Control Optimise pumping for swimming pool Altivar 12 Optimise swimming pool water management IHP2c Energy Saving with Zelio Logic

116 118 120

Energy managament Monitor and analyse elecrical consumption of a shopping centre

122

67


Energy Efficiency practical solutions

HVAC Control Automate lighting, temperature and shutter control in office buildings

Customer’s needs

Our recommendation

The facility manager wants to realise substantial energy savings by controlling all the parameters of lighting, heating and shutters and further to be able to extend easily the system at any time without laying new cables.

With the KNX bus system all devices will be connected via a single bus line. When you activate a sensor (example: a pushbutton), an actuator (example the roller shutter control) will carry out all the switching commands required. For this demand we will use a multi-function pushbutton in association with a brightness and presence sensor and with lighting, heating and sunblind actuators.

Energy Efficiency core products KNX ARTEC multi-function push-button with room temperature control unit. Convenient control unit with 4 operating buttons with room temperature control unit and display: QQ Functions of the multi-function push-button: OO Switching, toggling, dimming, blind control, pulse edges trigger, alarm functions, cyclic reading of external temperature values,… QQ Functions of the room temperature control unit: OOType of control: 2-step control, continuous PI control, switching PI control (PWM) Output: continuous in the range 0…100% or switching On-Off.

KNX

Bus system components!

KNX multi-function pushbutton

68


> Energy Efficiency benefits > Automation avoids relying on uncertain human action and secure savings while providing increased comfort and safety.

HVAC Control

> Energy saving by automatically extinguishing when it is not necessary.

Solution diagram

50%

up to

ving gy sa ener

KNX multi-function pushbutton

System component

Lighting control

Heating control

Sunblind control

KNX

KNX power supply

KNX Argus Presence sensor

KNX control unit

KNX Fan

Heating valve drive

KNX Blind

Blind

Fan coil Window contrast

Metallic grill

Remote control

Product

Description

Unit

Reference

KNX, multi-function

Multi-function pushbutton with room temperature control unit

1

628719

KNX, Power supply

Power supply 160 REG-K

1

684016

KNX ARGUS

ARGUS Presence with constant lighting control and IR receiver

1

630919

Remote control

IR-remote control Distance 2010

1

570222

KNX, Control unit

Control unit 0-10 V REG-K

1

646991

KNX, Fan

Fan coil actuator

1

645094

KNX, Blind

Blind actuator REG-K

1

649804

69


Energy Efficiency practical solutions

HVAC Control Combine lighting, temperature and shutter control in office buildings

Customer’s needs

Our recommendation

The facility manager of an office building wants to increase the users comfort in offices and realise elementary energy savings by controlling lights and heating.

via a single bus line a multi-function pushbutton in combination with lighting and heating switch actuators and with a presence detector. With this intelligent system, lighting will be dependent on people’s presence and heating control will be adjusted at the requested temperature and set into standby whenever a window is opened.

Energy Efficiency core products QQ KNX ARTEC multi-function pushbutton QQ with convenient control unit with 4 operating buttons with room temperature control unit and display: QQ Functions of the multi-function push-button: OO Switching, toggling, dimming, blind control, pulse edges trigger, alarm functions, cyclic reading of external temperature values … QQ Functions of the room temperature control unit: OO Type of control: 2-step control, continuous PI control, switching PI control (PWM) OO Output: continuous in the range 0…100% or switching On-Off. QQ KNX ARGUS Presence: OO Angle of detection: 360° OO Range: a radius of max. 7 m from installation site (at a mounting height of 2.50 m). OO Number of zones: 136 w. 544 switching segments OO Light sensor: infinitely adjustable from approx. 10 to 1000 lux using the ETS.

KNX

Bus system components!

KNX multi-function pushbutton

70

KNX ARGUS


> Energy Efficiency benefits > Automation avoids relying on uncertain human action and secure savings while providing increased comfort and safety.

HVAC Control

> Energy saving by automatically extinguishing when it is not necessary.

Solution diagram

35%

up to

ving gy sa ener

KNX multi-function pushbutton

System component

Lighting control

Heating control

KNX

KNX power supply

KNX Presence sensor

KNX Switch actuator

KNX Binary input module

Window contrast

Product

Description

KNX Heating actuator

Thermoel. valve drive

Unit

Reference

KNX, multi-function

Multi-function pushbutton with room temperature control unit

1

628719

KNX, Power supply

Power supply 160 REG-K

1

684016

KNX, ARGUS

ARGUS Presence

1

630819

KNX,Switch

Switch actuator REG-K

1

649204

KNX, Binary

Binary input REG-K

1

644492

KNX, Heating

Heating actuator REG-K

1

645129

71


Energy Efficiency practical solutions

HVAC Control Manage load shedding of your home electrical installation

Customer’s needs

Our recommendation

The homeowner would like to reduce his electricity bill by reduction of subscribed demand while avoiding breaking of the central circuit breaker when power consumption exceeds the power subscribed.

Installing a CDS load shedding contactor will permit to temporally stop supply to non-essential circuits and reduce output power.

Energy Efficiency core products QQ CDS are especially designed QQ to manage load shedding of electrical loads in residential and tertiary installations up to 36 kVA QQ The CDS single-phase load-shedding contactor sheds and restores loads in cascade of 2 nonpriority circuits (heating) in order to supply the priority circuit (lighting) according to the setpoint defined by the user (threshold set by knurled knob on the front face of the CDS) QQ The CDS reference 15908 is a single phase load-shedding contactor of 2 circuits in cascade mode.

CDS Prevent overconsumption!

CDS

72


> Energy Efficiency benefits > Increase the number of loads that can be managed without increasing subscribed demand. > Enhance continuity of supply: as soon as the power consumed approaches the power set, CDS sheds non-priority loads in cascade.

HVAC Control

> Reduce electricity bill by reduction of the power subscribed.

Solution diagram

10%

up to

L N 1 C60N Q1

ving gy sa ener

3

2 4

4 5 6 CDS

7

DPN Q2

N

1

DPN Q3

N

1

2

N DPN Q4

1

O - OFF

O - OFF

N

9 10 12

N

2

Living room lighting

H1

N

2

H2

DPN Q5

O - OFF

O - OFF

N

1

X1 X2

Bedroom lighting

N

2

X1 X2

Bedroom lighting

QQ The references and characteristics QQ of C60 breakers depend on the installed power and type of load QQ Indicator lights H1 and H2 indicate the load shed circuit QQ All the power circuits (heating, lighting) must be protected by circuit-breakers Product

Description

Unit

Reference

CDS

Load-shedding contactor

1

15908

C60N

Modular Circuit Breaker 2 poles

1

24206

DPN

Modular Circuit Breaker 1 pole + N

4

19252

H1

White indicator

1

18322

H2

Red indicator

1

18320

73


Energy Efficiency practical solutions

HVAC Control Manage ventilation in hotel bathroom

Customer’s needs

Our recommendation

The hotel manager wishes to lower the electrical energy consumption while providing guests with maximum comfort by installing an automatic bathroom ventilation system.

Ensure that the bathroom ventilation system is operational while the bathroom is in use and that it remains on only for a few minutes after the light has been switched off. A time-delay relay is used to prevent the extractor from switching off immediately and to ensure that it remains on during an adjustable time-delay period.

Energy Efficiency core products The solution is to use an RTC relay to supply the extractor when the bathroom light is switched on: QQ The ON-QQ OFF switch controls the lighting and ventilation at the same time QQ When the hotel guest switches off the lighting, the RTC relay continues to operate the ventilation QQ The ventilator stops after a preset operating time to ensure that any unpleasant smells and moisture are removed but prevents energy waste.

RTC Just enough!

RTC

74


> Automation ensures considerable energy saving by automatically extinguishing lighting and ventilation when it is not necessary. > The time delay can be set from 0.1 second to 100 hours.

HVAC Control

> Energy Efficiency benefits

Solution diagram

15%

up to

ving gy sa ener

Sw

Ventilation

Lighting

QQ The RTC QQ relay supplies its output 18 as soon as input Y1 is activated QQ The time delay starts when RTC input Y1 is disabled

Product

Description

Unit

Reference

RTC

Time delay relay

1

16067

C60N

Modular Circuit Breaker 1 pole

1

24050

Sw

ON-OFF switch

1

AYA0100121

75


Energy Efficiency practical solutions

HVAC Control Manage water heating in public buildings

Customer’s needs

Our recommendation

The technical supervisor of the city council wants to increase user comfort and make energy savings by controlling water heating in public buildings.

In public buildings, hot water tanks may be controlled by the combination of an IHP 1c programmable time switch and a CT contactor, equipped with an ACTc auxiliary contact.

Energy Efficiency core products Different types of operations are available: QQ Normal operation: OO the IHP 1c programmable time switch controls water heating. QQ Exceptional override operation: OO water heating may be started up by the user outside the programmed times, by pressing on the pushbutton. QQ Return to normal operation: OO since the last order received has priority, normal switching takes over again at the time of the next switching operation of the IHP 1c.

IHP Efficiency at your fingertips!

IHP 1c

76


> Automation ensures considerable energy saving by automatically extinguishing water heating when it is not necessary. > Easy modification of time switch program for special events and vacation avoids useless energy spending.

HVAC Control

> Energy Efficiency benefits

Solution diagram

10%

up to

L N C60N Q1

1

ving gy sa ener

3

2

4

S1

L

IHP 1c

ACTc T

L

1 3

23

O - OFF

X N

N 46

2 4

H1

CT + ACTo+f KM1

24

X1

X2

Gymnasium water heating

Unit

Reference

IHP 1C

Product

Description Programmable time switch

1

CCT15720

C60N

Modular Circuit Breaker 2 poles

1

24076

ACTc

CT auxiliary contactor

1

18308

CT

Contactor with manual operation

1

15391

ACTo+f

Auxiliary contact for CT contactor

1

15914

H1

Red indicator light

1

18320

77


Energy Efficiency practical solutions

HVAC Control Ensure effective operation of a cooling tower fan

Customer’s needs

Our recommendation

In an operation involving heat extraction from process cooling water, the customer wants to maximise the energy efficiency of the cooling tower, and reduce the electricity bill.

Using a variable speed drive, you can start the fan and control its speed. The drive is equipped with built-in PID control, and can even be connected to a building management system.

Energy Efficiency core products The Altivar 21 drive is easily integrated into building management system (BMS) as it offers several communication cards as options, LonWorks, BACnet, METASYS N2, APOGEE FLN: QQ Optimise and regulate water temperature in the heat rejection loop of the chilled water system QQ Increase the fan speed when more cooling is needed QQ Decrease the fan speed when there is little demand for cooling.

ATV 21 A new breath for your applications!

ATV 21

78


> Energy Efficiency benefits HVAC Control

> Speed control can generate huge energy savings in these applications. The return on investment is very short, usually between 9 and 24 months by reducing the electricity bill for large office buildings, hospitals and schools.

Solution diagram

30%

up to

1

3

5

2

4

6

ving gy sa ener

ATV21

Q1

5

3

1

1 Q2 2 3

4

5

6

T1

S2 1 Q3 2

S1

A1

A1 FLA

FLC

KM1 13 14

6

4

2

KM1

KM1 A2

From BMS

CC

PLC

VIA

P24

F

RC

RY

FLB

FLA

L3

FLC

CC

V

W W1

L1 U U1

V1

A1

L2

RUN

From BMS

M 3

Product

Speed Reference

Unit

Reference

ATV 21

Variable speed drive

Description

1

ATV21HU75N4

Q1

Circuit breaker

1

GV2L20

KM1

Contactor

1

LC1D09M5

Q2

Circuit breaker (rated at twice the nominal primary current of T1)

1

GV2L

Q3

Control circuit breaker

1

GB2CB05

S1, S2

Pushbuttons

1

XB2B or XA2B

T1

100 VA transformer 220 V secondary

1

-

79


Energy Efficiency practical solutions

Lighting Control Automate lighting of a building hall

Customer’s needs

Our recommendation

The facility manager wants to increase user comfort and make energy savings.

A 360° movement detector Argus installed on the ceiling of the entrance hall ensures automatic control of lighting only in case of presence of a person or of any other motion and according to brightness level. A switch (optional) hidden from user’s view, allows ON override of lighting if required.

Energy Efficiency core products QQ The CDM Argus 360 movement QQ detector allows a 360° detection in a radius of 12 m: OO it ensures automatic lighting of the hall according to a preset brightness threshold OO the brightness threshold is adjustable between 2000 lux (tripping in broad daylight) and 2 lux (tripping in darkness) OO the time delay keeps lighting switched on for a preset time after the last movement detection OO the time delay is adjustable between 10 seconds and 15 minutes. QQ Control of single-phase loads without relays up to a power of 1 kW.

CDM ARGUS With movement comes light! 80

CDM Argus 360


> Absence of switches within the reach of users avoids untimely switch-on and leads to power saving. > Automation ensures major energy savings, increased comfort and enhanced safety.

Lighting Control

> Energy Efficiency benefits

Solution diagram

15%

up to

L N 1 C60N

1

2

C60N

ving gy sa ener

2 Sw

13 L N L'

CDM ARGUS 360

A1

CT

A2 2 4

Lighting

QQ Parallel connection of several CDMs is possible to cover large QQ surfaces or to ensure coverage of several zones QQ The rating of the CT contactor protection circuit-breaker depends on installed power and load type QQ To cancel the switch Sw, connect the CDM Argus 360 output directly to the A1 input of the contactor CT Product

Description

Unit

Reference.

CDM ARGUS 360

Movement detector

1

564419

C60N

Modular Circuit Breaker 1 pole

1

24170

C60N

Modular Circuit Breaker 1 pole

1

24177

CT

Modular contactor 2 poles

1

15381

Sw

Switch

1

AYA0100121

81


Energy Efficiency practical solutions

Lighting Control Automate lighting of access to your home

Customer’s needs

Our recommendation

The private home-owner wants to ensure that exterior light automatically turns on when somebody comes in but only when it’s dark. It’s a matter of energy savings without compromising on comfort or safety.

A 180° movement detector installed at compulsory passing places ensures automatic control of lighting in the presence of a person or of any other motion and according to brightness level.

Energy Efficiency core products QQ The CDM 180 movement detector QQ allows detection within a 12 m by 6 m range 180°: OO it ensures automatic lighting of access points according to a preset brightness threshold OO the brightness threshold is adjustable between 1000 lux (tripping in broad daylight) and 2 lux (tripping in darkness) OO the time delay keeps lighting switched on during a preset time after the last movement detection OO the time delay is adjustable between 5 seconds and 12 minutes. QQ An optional Sw switch can be associated. It allows ON override of lighting if required QQ Control of single-phase loads without relays up to a power of 1 kW.

CDM With movement comes light!

CDM 180

82


> Energy saving by automatically extinguishing lighting when it is not necessary. > Automation avoids relying on uncertain human action and secures savings while providing increased comfort and safety.

Lighting Control

> Energy Efficiency benefits

Solution diagram

50%

up to

L N 1

ving gy sa ener

C60N

2

CDM 180

Sw

N

LS

L

Lighting

QQ The rating of QQ the protection circuit-breaker depends on installed power and load type QQ To cancel the Sw switch, connect directly the lighting circuit to the CDM 180 output LS

Product

Description

Unit

Reference

CDM 180

Movement detector

1

16974

C60N

Modular Circuit Breaker 1 pole

1

24177

Sw

Optional switch

1

AYA0100121

83


Energy Efficiency practical solutions

Lighting Control Automate public lighting according to sunrise and sunset

Customer’s needs

Our recommendation

The mayor of the commune wants to increase the reliability of public lighting operation to increase the comfort and safety of his citizens. But in the meantime he wants to monitor lighting operation time to make energy savings.

Use an astronomic programmable light sensitive switch allowing automatic switch-on and switch-off of lighting according to sunrise and sunset times.

He also wants to emphasise his architectural heritage thanks to nighttime lighting.

Energy Efficiency core products QQ The IC Astro light sensitive QQ switch is configured only according to the place of installation: OO either by selection of a country or town OO or by its geographical coordinates, latitude and longitude. Q A difference in sunrise and sunset times is adjustable separately by + 120 mn Q Intuitive programming and program saved up to 12 years if mains fail Q ON override external contact.

IC With darkness comes light!

IC Astro

84


> Energy Efficiency benefits Lighting Control

> Power saving by automatically extinguishing lighting when it is not necessary. > The change to summer/winter time is automatic. > Manual override of temporary or permanent ON and OFF status is possible.

Solution diagram

30%

up to

L3 L2

ving gy sa ener

L1 N 1

C60N

C60N

1

2

3

5

2 4 6 L

CT

IC Astro

N

4

6

1 3 5

A1 2 4 6

Lighting

QQ Maximum admissible power QQ of the IC Astro output contact depends on the load type QQ The rating of the CT contactor protection circuit-breaker depends on installed power and load type Product

Description

Unit

Reference

IC Astro

Light sensitive switch

1

15223

C60N

Modular Circuit Breaker 1 pole

1

24170

C60N

Modular Circuit Breaker 3 poles

1

24215

CT

Modular contactor 3 poles

1

15383

85


Energy Efficiency practical solutions

Lighting Control Automate lighting of surroundings of a building

Customer’s needs

Our recommendation

When a public or tertiary building requires illumination of its surroundings at night-fall, simple time programming is not sufficient to ensure safety and energy saving at the same time as the brightness threshold varies according to season and climate. The site manager wishes to light up the surroundings when the natural brightness threshold becomes insufficient, and switch off automatically when daylight is sufficient again.

The IC 100 light-sensitive switch is the ideal product for problem-free management of these needs. Once installed and its threshold set, it will automatically switch on and turn off the lighting at the right time. AÂ built-in time delay avoids untimely closing or tripping during undesired transient brightness conditions.

Energy Efficiency core products The solution is to set the lighting operation threshold on the IC 100 light-sensitive switch according to the external brightness measured by the wall-mounted cell: QQ The photoelectric cell detects low QQ brightness, causes closure of IC 50 contact and ensures lighting QQ The IC 100 monitoring light comes on when brightness threshold is reached and switches off lighting QQ Time delay on closing and breaking of contact: 10 seconds QQ Setting the tripping threshold from 2 to 100 lux.

IC With darkness comes light!

IC 100

86


> Energy saving by automatically extinguishing lighting when it is not necessary. > Automation ensures major energy savings, increased comfort and enhanced safety.

Lighting Control

> Energy Efficiency benefits

Solution diagram

15%

up to

L N

ving gy sa ener

1

C60N

Cell

2 I IC 100

N

Lighting

QQ For higher powers, relay using a CT contactor and its protective QQ circuit-breaker: their ratings depend on installed power and load type

Product

Description

Unit

Reference

IC 100

Light sensitive switch

1

15482

C60N

Modular Circuit Breaker 1 pole

1

24170

Cell

Wall-mounted cell

1

CCT15268

87


Energy Efficiency practical solutions

Lighting Control Control lighting in classrooms

Customer’s needs

Our recommendation

The training room fluorescent lights must come on when the presence of students in the room is detected, but only when the natural lighting is insufficient. They must go off when the natural lighting is sufficient or as soon as the room is empty, leading to energy saving.

Thanks to the CDP ARGUS presence detector’s lighting control, which is dependent on movement and brightness, only classrooms which are in use will be lit.

Energy Efficiency core products QQ The CDP QQ ARGUS allows the lighting to be set from 10 to 1000 lux QQ It detects the slightest motions within a radius of 14 metres at a mounting height of 2.5 metres QQ Thanks to the 2 relay outlets not only the lighting but also the HVAC can be controlled with just one device QQ You can also manually switch the lighting ON and OFF at any time using a pushbutton.

CDP ARGUS Keeping energy costs down!

CDP ARGUS

88


> Automation ensures considerable energy savings. > Additional energy saving potential can be gained by including the heating or air conditioning in the system: example by using night economy when no movement is detected.

Lighting Control

> Energy Efficiency benefits

Solution diagram

20%

up to

L N C60N

ving gy sa ener

1 3

Vigi C60

2 4

CDP L N L’ + ARGUS N L+1-10 V ballast

N L+1-10 V ballast

Fluorescent strip light

Fluorescent strip light

QQ The maximum switching current per relay: OO 10 A, AC 230 V, cos phi 0.6 OO Incandescent lamp max. 2300 W OO Halogen lamp max. 2000 W. QQ The diagram shows the TT earthing system used in France: OO The earthing system must be appropriate with the regulations in force in the country where the lighting is in use.

Product

Description

Unit

Reference

CDP ARGUS

Argus presence detector

1

MTN550590

Vigi C60

Add-on residual current module

1

26549

C60N

Modular Circuit Breaker 2 poles

1

24204

89


Energy Efficiency practical solutions

Lighting Control Control office lighting locally

Customer’s needs

The facility manager wants to optimise his operating cost by saving lighting energy in the offices.

Our recommendation Using IHP+2c and TL to control office lighting locally by pushbuttons and centrally by a programmable time switch.

Energy Efficiency core products The solution is to control the lighting of the building: QQ by a centralized order transmitted by QQ an impulse type IHP+ 2c to the ATLc+s impulse relay auxiliary. QQ The IHP+ 2c functions provide the benefit of centralised: OO time programming OO manual override operation. QQ locally by means of push-buttons and benefit from TL functions: OO blue remote control OFF on the TL OO manual operation using the TL toggle.

IHP Efficiency at your fingertips!

IHP+2c

90


> Energy saving by automatically extinguishing lighting when it is not necessary. > Easy modification of time switch program for special events and vacation avoiding useless energy spending.

Lighting Control

> Energy Efficiency benefits

Solution diagram

25%

up to

L N 1 3

2

1 3

C60N Q1

4

2

ving gy sa ener

C60N Q2

4

S1

S2 C2

TL+ATLc+s

1

A1

TL+ATLc+s

2 A2 on off

Office lighting

Product

1

A1

2 A2 on off

L

3

N

5

IHP+2c

46 C1

Office lighting

Unit

Reference

IHP+2c

Description Programmable time switch

1

CCT15723

C60N

Modular Circuit Breaker 2 poles

2

24204

TL

Impulse switch

2

15510

ATLc+s

Impulse relay

2

15409

91


Energy Efficiency practical solutions

Lighting Control Create restaurant mood lighting

Customer’s needs

Our recommendation

The restaurant manager wishes to control separately the lighting in the bar (halogen lighting) and in the restaurant (incandescent lighting) to create different atmosphere and adapt consumption.

The solution is to separate the bar and restaurant lighting systems into two separate areas. Two pushbuttons that can be accessed from the bar are used to vary the lighting manually. The Extra Low Voltage halogen lights in the bar are powered by a remote control dimmer via electronic transformers. The incandescent lights in the restaurant are powered by two associated remote control dimmers.

Energy Efficiency core products QQ The solution is to create two separate QQ areas controlled by two different types of dimmers: OO The bar area is lit by extra low voltage lighting: the Tve700 dimmer is associated with TFu electronic transformers OO The restaurant area is lit by incandescent lights. QQ The use of optical coupling to associate the Vo1000 and Tvo1000 dimmers increases the electrical output QQ The pushbuttons are used to adjust the brightness: OO a short press switches the lighting ON or OFF OO a long press increases or reduces the light output. QQ The dimmer direction is stored: OO a new long press increases or decreases the light output, according to the current dimmer direction. QQ No wiring is required, as the dimmers are associated via a fibre-optic BUS.

TV Light under your control! STD400

92

STD1000


> Energy Efficiency benefits Lighting Control

> The room lighting can be adapted to the customer’s requirements. > Dimming your light level ensures major energy saving, increased comfort.

Solution diagram

10%

up to

L N

C60N

1

3

2

ving gy sa ener

4 Restaurant area

Bar area PB

PB 1 3

1 3 STD400

2

4

STD1000

STD1000

TFu105 TFu105

2 4

2

4

Bar lighting Bar lighting

Restaurant Restaurant lighting lighting

Product

Description

Unit

Reference

STD400

Dimmer

1

CCTDD20001

STD1000

Dimmer

1

CCTDD20003

C60N

Modular Circuit Breaker 1 pole

1

24170

PB

Pushbutton

-

-

93


Energy Efficiency practical solutions

Lighting Control Ensure effective lighting of the entrance of a block of flats

Customer’s needs

Our recommendation

Shared building premises (entrance halls, cellars, garages,...) have the specific feature of episodic and irregular use. Moreover, they are normally located in dark places requiring lighting at all times of the day and night. Permanent lighting of these places is incompatible with the notion of energy savings.

By using one MINp timer, it is easy to efficiently manage temporary lighting of shared building premises. The early switch-off warning reduces light intensity by 50% just before the end of the period, thus enabling the restart a new 3-minute period in complete safety without reaching total darkness. If permanent lighting is needed (servicing, maintenance,...), the ON override function will ensure continuous operation of lights.

Energy Efficiency core products MINp timer with switch-off warning function integrated in the product: QQ The switch-off time delay can be set between 0.5 and 20 min QQ 1h fixed time delay is started by pressing the control pushbutton for more than 2 s QQ The MINp timers can control lighting up to 3600 W QQ Optional override in ON position.

MIN Just enough light!

MINp

94


> Energy Efficiency benefits Lighting Control

> Energy saving by automatically extinguishing lighting when it is not necessary. > Comfort and safety increased with the associated early switch-off warning.

Solution diagram

30%

up to

L N

ving gy sa ener

1 C60N

2

MINp

L

3 N

4

Lighting

QQ The MINp timer requires connection of pushbuttons in the installation phase QQ For higher powers, relay with a CT contactor and its protective circuit-breaker: their ratings depend on installed power and load type

Unit

Reference

MINp

Product

Description Timer

1

CCT15233

C60N

Modular Circuit Breaker 1 pole

1

24177

95


Energy Efficiency practical solutions

Lighting Control Manage automatic lighting by presence detection in home

Customer’s needs

Our recommendation

Parents want to reduce lighting-related energy spending while improving comfort and safety when their children enter the entrance halls, small corridors, garage, laundry rooms, … and when their hands are not free.

With Unica movement detectors the lighting switches on automatically when we need it. They can be flush or surface-mounted in indoor installation and quickly installed in place of single-circuit switches without changing the wiring.

Energy Efficiency core products Lighting control with the combination of people presence, time delay and luminosity threshold QQ Two types of operating modes are available: OO manual: the load is controlled by push-button OO automatic: the load is controlled by the detection of movement and by a predefined luminosity threshold. QQ Type of loads: OO incandescent: 230 VAC OO halogen lamps: 300 W max.

Unica CDM Light under your control! Movement detector switch

96


> Power saving by automatically extinguishing lighting when it is not necessary. > Automation ensures major energy saving, increased comfort and enhanced safety. > Lighting time is reduced to the minimum thanks to adjustable time setting from 2 s to 20Â minutes and with a luminosity threshold from 5 to 1000 lux.

Lighting Control

> Energy Efficiency benefits

Solution diagram Unica

Unica

Standard mounting: with or without normally-open pushbuttons for manual override

20%

up to

ving gy sa ener

Parallel mounting: used to extend the detection zone; with or without normally-open pushbuttons (5 pushbuttons) for manual override

Unica

Examples of substitution

Unica

Unica

Product

Description

Unica

Movement detector switch 300 W

PB

Pushbutton NO

Unit 1 to 3 Up to 5

Reference MGU3.524.18 —

97


Energy Efficiency practical solutions

Lighting Control Manage automatic lighting in large areas with movement detectors

Customer’s needs

Our recommendation

The building manager wants to reduce lightingrelated energy consumption and improve user comfort in the large entrance halls, long corridors, large conference rooms,…

With Unica movement detectors the lighting switches on automatically when we need it. They can be flush or surface-mounted in indoor installation.

Energy Efficiency core products Lighting control with combination of people presence, time delay and luminosity threshold QQ Two types of operating modes are available: OO Manual: the load is controlled by pushbutton OO Automatic: the load is controlled by detection of movement and by a predefined luminosity threshold. QQ Type of load: OO Incandescent lamps: 2300 W max OO Halogen lamps: 200 W max OO Low Voltage halogen with transformer: 1150 VA max OO Dimmable compact fluo lamps: 500 VA max.

Unica CDM Light under your control!

98

Movement detector switch


> Power saving by automatically extinguishing lighting when it is not necessary. > Automation ensures major energy saving, increase comfort and enhanced safety. > Lighting time is reduced to the minimum thanks to adjustable time setting from 2 s to 20Â minutes and with a luminosity threshold from 5 to 1000 lux.

Lighting Control

> Energy Efficiency benefits

Solution diagram L

L

20%

up to

Unica

ving gy sa ener

N

N Standard mounting using a maximum of 5 normally-open pushbuttons for manual override

L

L Unica

Unica

S1

Unica

L

L

N

S2 N

N

N Master-slave mounting: 5 slave movement detectors can be connected to a master; used to the extend the detection zone; a maximum of 5 normally-open pushbuttons per slave for manual override

Product

Description

Unica

Movement detector switch 300 W

PB

Pushbutton NO

Unit 1 to 3 Up to 5

Reference MGU3.524.18 –

99


Energy Efficiency practical solutions

Lighting Control Manage lighting in a garage

Customer’s needs

Our recommendation

The private home-owner wants to increase comfort without increasing his energy bill.

Set lighting times to a minimum in passageways using a timer to: QQ switch off one or more lights without using two-way pushbutton cabling (impulse relay function); keep lighting on for a pre-set time QQ switch it off automatically. Override timer for permanent lighting on need. Use “Switch-off warning” to improve safety.

Energy Efficiency core products The solution is to use a MINt timer: QQ Switch-off time delay can be set between 0.5 and 20 min QQ 1h fixed time delay can be started by pressing the control pushbutton for more than 2 s QQ The MINt timers can control lighting up to 3600 W QQ An “impulse relay function” is integrated in the product, allowing the lighting to be switched off or on by pressing a short time on the control pushbuttons QQ Automatic selection of the control pushbuttons connection facilitates installation QQ Mechanical compatibility with electrical distribution comb busbar enables easy installation on symmetrical rail QQ 30 luminous pushbuttons can be installed in parallel (up to 150 mA consumption) QQ The integrated “Switch-off warning” function warns that lighting is about to be switched off by flickering of the lamplight.

MIN Just enough light! MINt

100


> Automation ensures more energy savings and comfort with silent electronic timers. > The “impulse relay” reduces the time the load is switched on. > Different override modes (permanent, long duration) cover the various operation needs in the garage (long time repair,...). > User safety is increased using “Switch-off warning” function.

Lighting Control

> Energy Efficiency benefits

Solution diagram

30%

up to

L N

ving gy sa ener

1 C60N

2

MINt

L

3 N

4

3

Lighting

QQ The protection circuit-breaker rating depends on the installed power QQ CT contactor, if the power consumption exceeds 3600 W

Unit

Reference

MINt

Product

Description Timer

1

CCT15234

C60N

Modular Circuit Breaker 1 pole

1

24177

101


Energy Efficiency practical solutions

Lighting Control Manage lighting in a hotel corridor

Customer’s needs

Our recommendation

The hotel manager wants to increase user comfort and save on lightingrelated energy costs.

Set lighting times to a minimum in passageways using a timer to: QQ switch on one or more lights from one or more control points; keep lighting on for a pre-set time QQ switch it off automatically. Override timer for permanent lighting on need. Use “Switch-off warning” to improve user safety.

Energy Efficiency core products QQ MINs timer associated with PRE switch-off warning OO The switch-off time delay can be set between 0.5 and 20 min OO The MINs timers can control lighting up to 2300 W QQ Automatic selection of the control pushbuttons connection facilitates installation QQ Mechanical compatibility with the electrical distribution comb busbar makes the product easy to install on symmetrical rail QQ 30 luminous pushbuttons can be installed in parallel (up to 150 mA consumption).

MIN Just enough light!

MINs

102


> Automation provides significant energy savings and greater comfort with silent electronic timers. > Different override modes (permanent, long duration) cover the hotels various operation needs (cleaning, maintenance,...).

Lighting Control

> Energy Efficiency benefits

Solution diagram

30%

up to

L N

ving gy sa ener

1 C60N

2 A2

A1

L

3 N

4

3

MINs

PRE

Lighting

QQ The protection circuit-breaker rating depends on the installed power QQ CT contactor, if the power consumption exceeds 2300 W

Unit

Reference

MINs

Product

Description Timer

1

CCT15232

C60N

Modular Circuit Breaker 1 pole

1

24170

PRE

Switch-off warning

1

15376

103


Energy Efficiency practical solutions

Lighting Control Manage lighting in building stairways

Customer’s needs

Our recommendation

Oversight or neglect? A Building manager has observed that the communal area lightings are very often switched-on! He would like to remedy this situation and to reduce lightingrelated energy consumption while improving user comfort. His objective is to cut by 10% the related lighting consumption in these areas.

Control the switch-on time with a Unica time delay switch. Additional remote push-buttons could be connected for remote control. The Unica switches can be flush-mounted or surface-mounted in indoor installation with a wide choice of cover frames to fit all the decors.

Energy Efficiency core products QQ Easy location of the time delay switch QQ in the dark by a large blue locator lamp on the front QQ The time delay is adjustable between 2 seconds and 12 minutes QQ Lighting control with time delay switches may also be used in entrance halls, corridors, toilets,…

Unica Timer Light under your control! 104

Time delay switch


> Just push the button and the lighting switches on, for just as long as you need it. > The timer is adjustable from 2 s to 12 min. You can save at least 400 lighting hours per area and per year (one hour less per day).

Lighting Control

> Energy Efficiency benefits

Solution diagram Unica

10%

up to

ving gy sa ener

Connection diagram: up to 25 normally-open pushbuttons may be connected for remote control

Product

Description

Unit

Reference

Unica

Time delay switch

1

MGU353518

C60N

Modular Circuit Breaker 1 pole

1

24177

PB

Pushbutton NO

up to 25 –

105


Energy Efficiency practical solutions

Lighting Control Manage lighting in various parts of a shop

Customer’s needs

Our recommendation

The shop manager wants to control the energy consumption while maintaining an appropriate lighting level in the different parts of his shop.

A time switch IKEOS offers all the necessary features in a single product: QQ Shop and window lighting limited to opening times QQ Time delay of storeroom lighting QQ Flashing of the illuminated shop sign in association with a light sensitive switch when night falls.

Energy Efficiency core products The ITM multifunctional time switch is used to control 4 output channels (C1 to C4) according to the status of 3 inputs (E1 to E3). The E3 input is conditioned by the level of external brightness controlled by the light sensitive switch. Output

Use

C1

Window lighting

Type of input used Functions -

Connected components -

C2

Stock room lighting Timer

E1

Control input

Pushbutton PB

C3

Sales area lighting Weekly time

E2

Override input programming

Switch Sw

C4

Neon sign

E3

Condition input

Light sensitive switch

IKEOS Program, time delay, count. IKEOS: let yourself be guided! IKEOS

106

Type of function used Input Programming Weekly time programming

Flashing


> Automation ensures better control of energy expenses by automatically extinguishing lighting when it is not necessary. > Energy saving while emphasising the shop window and lighted signs.

Lighting Control

> Energy Efficiency benefits

Solution diagram L N

25%

up to C60N

1

C60N

1

ving gy sa ener

Cell

2

2 L

L N 12 3

BP

IKEOS

3 5

IC2000

Sw

N4

1 C60N

2 13 A1

CT

A2 2 4 Window

1 C60N

1 C60N

2 13 A1

CT

A2 2 4

2 13 A1

CT

A2 2 4

Storeroom

6

1 C60N

2 13 A1

CT

A2 2 4

Sales

Sign

QQ Output C1 allows lighting of the shop window at the required times and days QQ Output C2, programmed in timer function, receives the operating authorisation from pushbutton PB connected to input E1 QQ Output C3 authorises lighting of the sales area at the required times and days. It can be forced by the switch Sw cabled to the input E2 QQ Output C4 makes the shop sign flash when the light sensitive switch connected to E3 enables it to do so Product

Description

Unit

Reference

IKEOS

ITM Multifunctional switch

1

15270

IC 2000

Light sensitive switch

1

CCT15368

Cell

Wall-mounted cell

1

CCT15268

C60N

Modular Circuit Breaker 1 pole

2

24170

C60N

Modular Circuit Breaker 1 pole

4

24177

CT

Modular contactor 2 poles

4

15381

Memory

Memory cartridge

1

15280

107


Energy Efficiency practical solutions

Lighting Control Monitor lighting time and manage the bells in a school

Customer’s needs

Our recommendation

The school director wants to optimise his operating costs by saving lighting energy and to automatically start school bells at the right time.

Limit the amount of lighting used to the number of hours required for school activities by programming the times during which classrooms and common areas need to be lit. Monitor how long the lighting is used and be informed when the time is exceeded (for maintenance purposes). Program bell operating times and durations.

Energy Efficiency core products QQUse IHP+2c programmable time switch to program: OO on IHP+2c output 1; the days and times when the lighting should be switched on (example: Monday to Friday 8 h 15 to 9 h 30 and 15 h 30 to 18 h 30) OO on IHP+2c output 2; the day, time and duration of school bell operation using the pulse function (example: Monday to Friday every hour from 8 h 30 to 16 h 30, the bells operate 20 s). QQ Use a pushbutton connected to the external input 1 for off-hours timer operations QQ 84 switching operations to offer large programming capacities QQ Output operating hours counter for maintenance purposes QQ Mechanical compatibility with electrical distribution comb busbar for easier installation on symmetrical rail QQ Screw-less terminals for easy and fast connection.

IHP Efficiency at your fingertips!

IHP+2c

108


> Energy saving by automatically extinguishing lighting when it is not necessary. > Easy modification of time switch program for special events and vacation, avoiding useless energy spending. > Automatic summer/winter time change.

Lighting Control

> Energy Efficiency benefits

Solution diagram

50%

up to

L

ving gy sa ener

N 1

1

C60N

2

1

C60N

C60N

2 IHP+2c

L

3

1 3

5

CT A1

PB Ext1 N

4

2 4

6

A2

School bells

Lighting

QQ Circuit-breakers to protect the devices and lighting circuits QQ CT contactor, to manage the school lighting QQ The characteristics of protection circuit-breakers and CT contactor depend on the installed power and type of load Unit

Reference

IHP+2c

Product

Description Programmable time switch

1

CCT15852

C60N

Modular Circuit Breaker 1 pole

2

24170

C60N

Modular Circuit Breaker 1 pole

1

24177

CT

Modular contactor 2 poles

1

15381

PB

Pushbutton

1

—

109


Energy Efficiency practical solutions

Lighting Control Optimise hotel car park lighting

Customer’s needs

Our recommendation

The hotel manager wishes to optimise car park lighting operation and control energy costs. He wants to increase the hotel guests’ comfort and safety.

A light sensitive switch automatically controls the car park lighting (ON or OFF) according to the external brightness and the predetermined light sensitive switch threshold.

Energy Efficiency core products The solution is to set the lighting operation threshold on the IC2000 light-sensitive switch according to the external brightness measured by the wall-mounted cell: QQ Adjustable brightness threshold from 2 to 2000 lux QQ Screw-less terminals for easy and fast connection QQ Delivered rotating wall-mounted cell for easier installation.

IC With darkness comes light!

IC2000

110


> Energy Efficiency benefits Lighting Control

> Power saving by automatically extinguishing lighting when it is not necessary. > Avoiding relying upon uncertain human action secures savings. > A heightened feeling of safety is provided at minimum cost as the lighting is always “ON� when it is dark.

Solution diagram

25%

up to

L3 L2

ving gy sa ener

L1 N C60N

1

1

Cell

2

3

5

C60N

2 4 6 L

3 5

IC2000

1 3 5 A1

N

4

6

CT

A2 2 4 6

Car park lighting

QQ Circuit-breakers to protect the devices and the lighting circuits QQ CT contactor, if power consumption exceeds 2300 W QQ The characteristics of protection circuit-breakers and CT contactor depend on the installed power and type of load Unit

Reference

IC2000

Product

Description Light sensitive switch

1

CCT15368

C60N

Modular Circuit Breaker 3 poles

1

24215

C60N

Modular Circuit Breaker 1 pole

1

24170

CT

Modular contactor 3 poles

1

15383

Cell

Wall-mounted cell

1

CCT15268

111


Energy Efficiency practical solutions

Lighting Control Optimise room lighting through the use of dimmers

Customer’s needs

Our recommendation

The homeowner wants to reduce lighting-related energy consumption, change room atmosphere and improve comfort.

Using a dimmer enables the homeowner to control light level independently and allows him to control light sources from one or several control points.

Energy Efficiency core products Four Unica dimmer switches are available, according to the type of load to be controlled, the type of dimming (push button or rotary) and the possibility of associating them with other control devices. QQ Unica dimmer switches can: OO save energy, since dimmed lighting uses less electricity than full power lighting OO extend the lifetime of the light using the soft-on dimmer function OO adapt the light level to fit the desired atmosphere in the room OO regulate the lighting by simply pressing or rotating, according to the choice of product OO be installed easily without changing the wiring.

Unica Dimmer Light under your control! Dimmer

112

Dimmer


> Wall box dimmers allow reduction of energy used for lighting. > Instead of having lights only ON or OFF, light level can be adjusted to required level. > Dimming your light level by 25% saves 20% in energy.

Lighting Control

> Energy Efficiency benefits

Solution diagram

L

Unica

20%

up to

N

ving gy sa ener

L

Product

Description

Unit

Reference

Unica

Pushbutton dimmer switch

1

MGU50.515.18Z

C60N

Modular Circuit Breaker 1 pole

1

24177

PB

Pushbutton

up to 25 –

113


Energy Efficiency practical solutions

Lighting Control Optimise shop-window lighting

Customer’s needs

Our recommendation

The shop owner wants to light up the shop window at nightfall and save energy by automatically switching off the lighting late at night when the streets are empty. He wants to prevent the lighting from switching on, on shop closure days.

A programmable light-sensitive switch automatically controls shop-window lighting according to brightness and/or the time of the day.

Energy Efficiency core products QQ IC2000 P+ light sensitive switch associated with a wall-mounted cell: OO program on the IC2000P+, the period when you might need light (example: from 9 p.m. to 6 a.m. except Sunday) OO set the lighting operation threshold on the IC2000P+ according to the external brightness (example: 20 lux). QQ Switching the external input on turns on the light permanently QQ The IC2000P+ can control lighting up to 2300 W QQ Adjustable light level from 2 to 2100 lux QQ Adjustable time delay to prevent unwanted operation in case of short variance of light.

IC With darkness comes light! IC2000P+

114


> The change to summer/winter time is automatic. > Excellent shop-window lighting as soon as night starts to fall.

Lighting Control

> Energy Efficiency benefits > Power saving by automatically extinguishing lighting when it is not necessary and when there are fewer passers-by.

Solution diagram

25%

up to

L

ving gy sa ener

N 1

Cell

C60N

2

1

C60N

2 L

3 5

IC2000P+

N

4 6

Shop-window lighting

QQ Circuit-breakers to protect the devices and lighting circuits QQ CT contactor, if power consumption exceeds 2300 W

Product

Description

IC2000P+

Light sensitive switch

Unit

Reference

1

15483 24170

C60N

Modular Circuit Breaker 1 pole

1

C60N

Modular Circuit Breaker 1 pole

1

24177

Cell

Wall-mounted cell

1

CCT15268

115


Energy Efficiency practical solutions

Motor Control Optimise pumping for swimming pool

Customer’s needs

Our recommendation

The private home-owner wants to save energy while optimising the water flow in his filtration system, keeping water moving for chemical dispensers and chlorinator efficiency.

To minimise the pump energy costs, you should operate at the lowest possible flow rate. With a variable speed drive ATV 12 placed between the circuit breaker and the motor, flow variation is achieved by electronically controlling the speed of the motor.

Energy Efficiency core products The Altivar 12 drive combines all the functions that your application requires: QQ Reduction of energy consumption QQ Flow variation QQ Simplicity of use QQ Motor protection.

ATV 12 Real efficiency at a reduced size!

ATV 12

116


> Energy Efficiency benefits Motor Control

> At 80% of the flow, power consumption drops by 50% using a variable speed drive! > Energy savings reach huge amounts, optimising water flows for any application, filtration, cleaning, spa and heating‌

Solution diagram

30%

up to

ving gy sa ener

ATV 12

200...240 V 50/60 Hz N 5

Q2 1 2

6

3

3 4 5 6

3 4

1 2

Q1

T1

S2 1 Q3 2

S1

Q2

A1 RA

KM1 13 14

LI4

LI3

LI2

LI1

+5V

DO

RC

RA AI1

0V

W/T3

S/L2/N M1 3

RC

KM1 A2

KM1

W1

V/T2

4

R/L1

V1

U1

U/T1

2

KM1

A1

A1

+ 15 V

1

L

Variable pump

3-phase motor 200...240 V

Pressure sensor 0-20 mA 4-20 mA 0+5 V 0+10 V

Product

Description

A1

ATV 12 variable speed drive

1

Unit

Reference ATV12H018M2

Q1

Circuit breaker

1

GV2ME07

KM1

Contactor

1

LC1K09

P1

Potentiometer 22kOhm

1

RV1202

117


Energy Efficiency practical solutions

Motor Control Optimise swimming pool water management

Customer’s needs

Our recommendation

The swimming pool manager wants to optimise the operation of the various pool areas:

Automated pool management via a dual-output programmable time switch.

QQ the swimming pool water must be filtered continuously on the days the pool is open

The first output controls the pool water filtering pump and the second controls the footbath water supply solenoid valve.

QQ the water supply to the footbaths must only be operational during opening times.

Energy Efficiency core products The solution is to use IHP 2c programmable time switch: QQ To program on IHP 2c output 1; the days and times the pool water will be filtered (example: every day from 8 a.m. to 8 p.m.) QQ To program on IHP 2c output 2; the days and times the footbaths will be operational (example: filled with water ½ h before the swimming pool opens and emptied ½ hour after it closes) QQ Up to 6 years power backup in the event of mains failure.

IHP 2c Efficiency at your fingertips!

IHP 2c

118


> Energy Efficiency benefits Motor Control

> Optimised management of swimming pool operation. > Possibility of temporary or continuous override operation (ON or OFF). > Automatic summer/winter time change.

Solution diagram

25%

up to

L3 L2

ving gy sa ener

L1 N C60N

1

1

C60N

2

1

3

2 L

3

5

2 4 6 L 3 5

5 A1

IHP 2c

N

4

C60N

CT

A2

6

Footbaths

2 4 6

Pool filtering pump

QQ Circuit-breakers to protect the various devices QQ The footbath water-filling solenoid valve is directly controlled by the IHP 2c switch contact QQ The characteristics of protection circuit-breakers and CT contactor depend on the installed power and type of load Product

Description

IHP 2c

Programmable time switch

Unit

Reference

1

CCT15852 24170

C60N

Modular Circuit Breaker 1 pole

1

C60N

Modular Circuit Breaker 1 pole

1

24177

C60N

Modular Circuit Breaker 3 poles

1

24215

CT

Modular contactor 3 poles

1

15383

119


Energy Efficiency practical solutions

Motor Control Home Automation

Customer’s needs

Our recommendation

The home occupant wants to centrally control the heating system, the water heater, electric blinds, lighting, the swimming-pool management and lighting system and garden plant watering.

Zelio Logic offers an easy and flexible way to save energy, comfortable conditions, full control, and notification in case of errors: QQ All systems can be controlled via mobile phone (change configuration / switch systems on-off / error messages). QQ Flexible and configurable thanks to its central controller. QQ Accessible via touch screen for control and visualisation. QQ Can connect to Unica Wireless products for wireless control*.

Energy saving with simple products Zelio Logic is designed to control up to 16 channels (outputs) according to the signals received through its 24 inputs. All functions are specified by the software of the module, Zelio Soft 2. Output

Programming

5 6

Blinds control command

Daily schedule & local control

Swimming pool pump control command Zelio logic on-screen level display Motorized garden valve switch control command

Tank diesel limit level control / alarm

2 3 4

7

8

120

Function

Daily schedule / local control / time delay / creation of scenarios Swimming-pool lighting Daily schedule / local control / time delay / command creation of scenarios Burner switch on Weekly schedule command Motorised heating radiator valve switch on Time delay in relation to the burner command Blinds control command Daily schedule & local control

1

RF lighting command

Input

Input type

Input product

4

Simple contact

4

Simple contact

Brightness sensor with adjustable limits Brightness sensor with adjustable limits

2

Simple contact

Room thermostat

2

Simple contact

Room thermostat

1

Simple switch

3

RF switch

Switch / button General purpose RF relay receiver

Button

Zelio Logic Æ1 button

8

Analog signal

Ultrasound sensor

Button

Zelio Logic Z2 button

Daily schedule & local control / operational limit scenario creation

Daily schedule & local control


> Energy Efficiency benefits Motor Control

> Room temperature control with a daily schedule. > Water heater control with switching on/off schedule. > Lighting control with creation of scenarios according to ambient luminosity. > Swimming-pool management system control (temperature / pump / lighting). > Houseplant watering control with a daily schedule. > Energy saving with full control of heating & lighting.

Program and save!

30%

up to

ving gy sa ener

Solution Diagram

Products used Description

Unit

Code

Zelio Logic Unit (16 inputs / 10 outputs 24VDC)

1

SR3B261BD

Communication module

1

SR2COM01

GSM modem

1

SR2MOD02

Power supply 24 VDC / 1.2 A

1

ABL8MEM24012

Photocell switch IC 2000

1

CCT15368

Ultrasonic sensor 1m 0-10 V output

1

XX930A1A1M12

General purpose RF transmitter

1

CCT1A030

General purpose RF relay receiver

1

CCT1A031

Mixed-component RF transmitter-receiver

1

MGU3.572.XX

121


Energy Efficiency practical solutions

Energy Management Monitor and analyse electrical consumption of a shopping centre

Customer’s needs

Our recommendation

The manager wants to identify excessive or unnecessary electrical energy use by controlling the consumption in different areas of the shopping centre and to allocate cost to the appropriate cost centre.

A three-phase meter with neutral ME4zrt counts the total energy consumed by the installation; measurement is taken using current transformers. A three-phase meter ME3zr measures the energy of the specific furnace circuit. A 3 single-phase meter ME1zr measures the active energy of the other circuits. A yellow indicator light on the front face of the meter flashes according to consumption.

Energy Efficiency core products PowerLogic ME W/hr meters are designed for measurement of Watt-hours by a single-phase or three-phase electrical circuit.

ME Make sure you don’t miss anything! ME3zr

122

ME4zrt

ME1zr


> Permanent visualisation of consumption helps to encourage more efficient use of energy and create more disciplined behaviour among those in charge of business lines.

Energy Management

> Energy Efficiency benefits

Solution Diagram

10%

up to

ving gy sa ener

Products used Product

Description

Unit

Reference

ME3zr

Three-phase meter

1

17076

ME4zrt

Three-phase with neutral meter

1

17072

ME1zr

Single-phase meter

3

17067

C60N

MCB 4 poles

1

24234

C60N

MCB 3 poles

1

24221

C60N

MCB 2 poles

3

24208

TI 75/5

Current transformer 75/5

3

16502

123


Ideas and recommendations

to be Efficient

124


Ideas to be

Efficient Tips and best practices for saving energy in the daily people’s lives. Residential sector Replace traditional bulbs with tungsten filaments by compact fluorescent lamps (CFLs) or LED technology. Traditional bulbs consume up to 75% more energy. Turn off the lights when leaving a room, because the peak consumption at turning on the light is equivalent to an average of 24 seconds of operation for fluorescent tubes, one to two seconds for LED technology, and less than a second, for compact fluorescent lamps. However, repeated turning off and on of low energy lamps and fluorescent tubes shortens their lifecycles. Keep clear and unobstructed areas, where radiators are located, otherwise their performance is negatively affected. Buy appliances with the best energy class. There are 7 kinds of energy efficiency, identified by a color coding and letters (from the green color and the letter A for the most efficient equipment, to the red color and the letter G for the least efficient ones). Turn off televisions and video game consoles, their residual consumption may cost up to €60 a year.

125


Ideas to be

Efficient Buildings sector Select appropriately the temperature preset on the thermostats. Each additional degree of temperature can generate increases in heating costs by up to 8%. Make sure that the heating is synchronized with the periods when the building is occupied. Insulate properly the building envelope; the heat loss can be reduced by 90%. Clean the lamps regularly (once a year). The dirt on them can significantly reduce the efficiency of lighting. Regularly clean the windows. The dirt on the glass hinders the natural light. Also, make sure that the blinds are opened to allow the use of natural light. Leaving the copying machine in hibernation when not in use, and turn off at the end of the day, a copier that is left overnight uses enough energy to make 1,500 copies. Program monitors to go into hibernation mode when inactivity is detected; they consume two-thirds of the energy required by Computers. When the employees leave their jobs, computers should be shut down.

126


Ideas to be

Efficient Industry sector Shutdown, whenever possible, all ancillary facilities where production machinery is not working. The consumption of manufacturing plants when they are not in operation, but on standby, can be up to 30%, because although the machines are off, ancillary facilities stay on. Install more efficient electric motors; in a typical factory they consume 60% of energy. An electric motor can consume the energy that is equivalent to its purchase price in 2 months’ time. It is important to select power that is adequate for the load they will support, since the efficiency of an engine that works outside its nominal point drops dramatically. Avoid installing oversized power motors and use variable speed drives to maximize engine performance at different operating regimes. Immediately repair leaks in compressed air systems. All gaskets, seals, hoses and couplings should be checked frequently. An effective leak detection system is very useful and its cost of implementing it is reduced. Install quick opening doors or strip curtains in all the interior doors of trucks. In many cases, they become amortized in less than a year. The batteries of electric trucks should be loaded after hours of peak electricity demand (evening/night).

127


Notes

128


Notes

129


Energy Efficiency label Our EE labels help you make the right choice

This Energy Efficiency solutions label indicates the potential energy savings you can expect from the solution. These solutions enable sustained energy efficiency.

This Energy Efficiency label marks the products which are at the heart of the solution. Thanks to these ranges you can make the difference compared to a traditional solution.

Schneider Electric Polska Sp. z o.o. ul. Iłżecka 24, 02-135 Warszawa Centrum Obsługi Klienta: 0 801 171 500, 0 22 511 84 64 www.schneider-electric.pl Nr.: PD4PLKATKT28750 130

Schneider Electric enables you to make a concrete difference! April 2010


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.