City of London Freemen's School Masterplan & Main House 20.11.17
Consented Masterplan
3. Adopted Masterplan layout
– School embarked on a masterplan in 2008 – To chart a course for physical development of the campus over ten years New Car Park [98 spaces] New Changing Facilities More effective accommodation for dining, functions, student boarding and administration Relocated Junior School playground New Music School New Boarding House Accommodation New Swimming Pool, Energy Centre and School Reception
Hawkins\Brown © | City of London Freemen's School
Current Masterplan – The masterplan proposed four phases of development – Whilst the proposed development of works has remain unchanged the phasing has Extended Car Park - Phase 1 Replacement Swimming Pool - Phase 2 New Changing Room - Phase 2 Refurbishment of Main House to sixth form centre - Phase 3 Energy Centre - Phase 3 Redevelopment of landscape - Phase 4
New Music School - Phase 1 New Boarding House - Phase 1 Landscaping around Philp House site Phase 4 Hawkins\Brown © | City of London Freemen's School
Phase 1 Boarding House
Hawkins\Brown © | City of London Freemen's School
Phase 1 Music School
Hawkins\Brown © | City of London Freemen's School
Phase 2 Swimming Pool
Hawkins\Brown © | City of London Freemen's School
Rationale for Development Pedagogy – Providing flexible environments that respond to educational change and foster collaborative working and independent thought
Hawkins\Brown Š | City of London Freemen's School
Rationale for Development Pedagogy – Providing flexible environments that respond to educational change and foster collaborative working and independent thought Improved Facilities – Dining facility that suits the needs of an establishment of its size – The Junior School to accommodate the number of students – Sixth form has grown from 124 to 220 since being accommodated in the Stable Block – Improve Assembly Hall provision Hawkins\Brown © | City of London Freemen's School
Rationale for Development Planning & Operational Constraints – Owing to planning and operational constraints future proofing is important in any forward planning – Important that decisions made maximize the limited potential the site yields
Hawkins\Brown Š | City of London Freemen's School
Rationale for Development Planning & Operational Constraints – Owing to planning and operational constraints future proofing is important in any forward planning – Important that decisions made maximize the limited potential the site yields Local Competition – The school has already acheived some excellent facilities in the first stages of the Masterplan – Continue it's efforts in order to remain competitive
Rationale for Development Planning & Operational Constraints – Owing to planning and operational constraints future proofing is important in any forward planning – Important that decisions made maximize the limited potential the site yields Local Competition – The school has already acheived some excellent facilities in the first stages of the Masterplan – Continue it's efforts in order to remain competitive Supporting The City of London Corporation – A wider reach Hawkins\Brown © | City of London Freemen's School
Site Analysis Site Constraints Post
– Heritage restrictions across the school campus
Archaeologically sensitive area
SV UTT No Signal
89.81 RS
89.9 2
90.06
90.01 89.79 LB
89.83
87.98 89.85
89.85
88.91
90.19
89.94
TP
89.41
89.98 90.03 90.24
90.17
90.26
89.66
90.61
8
90.94
90.69
90.67
90.94
90.26
?
90.88
Existing plant serves 7 buildings
T5
89.8
SC UTT
Pipe
RS
90.56 90.72
Li m e CTV?
ER
LP
W alk
LP
CTV
Ground Light UTT
BT Flooded Chamber No BT cables visible
BT
UTL Traffic Sensitive
Poor entrance experience
Pa r
k
La
ne
South Wood
Grade II Listed Stable Block 99.06
99.93
PT
PT
PT
PT
PT
PT RE
99.97
100.10
– Restricted expansion opportunities
Impinges on key view of Main House
Gas UTT
– Key views from St Giles Church
North East Wood
88.00
– Existing plant within Philp House
North West Valley and Wood
VP UTT
Grade II* Listed Main House
ue ven eA Lim
Dense main area of accommodation
SV UTT Plastic
N
0
20
40
60
80 M
Hawkins\Brown © | City of London Freemen's School
Site Analysis Site Opportunities Post
– Maintain and improve the important heritage assets Opportunity to re-route traffic
SV UTT No Signal
89.81 2
90.06
88.00
LB
89.85
89.85
88.91
90.19
89.94
TP
89.41
89.98 90.03 90.24
90.17
90.26
89.66
90.61
T5
89.8 8
90.94
90.69
90.67
SC UTT
90.94
90.26
Pipe ?
90.88
Enhance views to Main House
RS
89.9
90.01 89.79
89.83
87.98
Gas UTT
– Use the Main House for teaching & learning
90.56
RS
90.72
ER
LP
CTV
Ground Light UTT
Flooded Chamber No BT cables visible
BT
UTL Traffic Sensitive
Potential zone for development Opportunity for Landscape enhancement 99.06
99.93
PT
Demolish existing Junior School and construct new purpose built facility
PT
PT
PT
PT
PT RE
99.97
100.10
– Set new targets for sustainable development and operation
CTV?
BT
– Raise the visual quality of the campus
LP
VP UTT
SV UTT Plastic
Opportunity to bring Main House into use for teaching
N
0
20
40
60
80 M
Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal
01
01
Key Proposed main entrance from Rookery Hill
02
Proposed reception building
03
Extended and reconfigured car parking layout for 190 cars
04
Coach layby for 4 no. coaches
05
Proposed Junior School building
06
Proposed access road exit
07
Proposed Assembly Hall
08
Proposed dining hall with external dining terraces
09
Proposed boarding house extension
10
Re-landscaped area
11
Main House (Grade II* Listed Building)
12
Swimming pool
13
Existing sports hall
14
03
04
12
02 14
13
05 10
06
11
07
08 09
Proposed vehicular table top crossing
Hawkins\Brown Š | City of London Freemen's School
Masterplan Proposal Junior School 01
01
Sun sail providing shade
Outdoor play space
02
01
03
04
02 03
03
Seating adjacent soft landscape 03
Proposed feature tree planting
Planting for year round interest 04
Shared surface with natural stone Hawkins\Brown Š | City of London Freemen's School
Masterplan Proposal Academic Quarter and Dining Hall 01
02
Stage for outdoor performances
01
03
Amenity spaces 03
04
Educational growing gardens 03
04
Integrated seating for socialising
04
02
External dining terrace Hawkins\Brown Š | City of London Freemen's School
Masterplan Proposal Access Routes and Junior School Play 01
02 02
01 04
Existing junior play to be extended
Enhanched landscape
05
03
02
05
Existing junior play to be extended
Junior hard play area
04 03
Rich sensory planting to provide year round interest Hawkins\Brown Š | City of London Freemen's School
Masterplan Proposal Vehicular Access T5
KEY MAIN ENTRANCE
One-way traffic
Controlled access point
Restricted two-way access for emergency/delivery vehicles and disabled parking
Car parking 190 spaces Coach parking (4 no.) Security Entrance Lodge
Controlled access point EXIT 2 no. disabled parking bays and 5 no. minibus parking bays
Project
Controlled access point 2 no. disabled parking bays
Project Nam Project Addr
Drawing
Existing Mas
3 no. disabled parking bays
Scale
1:1000 @ A3
1:1250 @ A1 0
20
40
60
80 M
Drawn by
MW Job Number
HBXXXX N
Drawing No. & Rev
1692_00_00
Hawkins\Brown Š | City of London Freemen's School
Masterplan Proposal Pedestrian Access T5
KEY Shared cycle and pedestrian routes Pedestrians
Project
Cycle parking
Project Name Project Addre
Cycle parking
Drawing
Existing Mast
Scale
1:1000 @ A3
1:1250 @ A1 0
20
40
60
80 M
Drawn by
Cycle parking
MW Job Number
HBXXXX N
Drawing No. & Revi
1692_00_001
Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 1 – Decant dining & catering into temporary dining – Construct new changing facilities adjacent to Sports Hall – Decant Bursars and Marketing into Philp House
Demolish OFA Club House Decant Bursars and Marketing to Philp House Temporary Dining Facility
Design: 3 months Procurement: 3 months Planning: 3 months Construction: 6 months Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 2 – Refurbish and remodel Main House to provide new Sixth Form Centre – Construct new Energy Centre – Internal refurbishment of Teddy Bear Cottage to provide new Medical Centre
Refurbish & remodel Main House New Energy Centre
Medical Centre relocated to Teddy Bear Cottage
Design: 6 months Planning: 3 months Procurement: 3 months Construction: 18 months Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 3 Upon Completion of works to Main House phasing of masterplan would commence: – Refurbish stable block for Bursars, classrooms and new library – Refurbish existing library for new classrooms – Demolish Philp House
Demolish Philp House Bursars & Marketing; additional classrooms, new Library and Careers Library
Design: 6 months Planning: 3 months Procurement: 6 months Construction: 12 months Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 4 – Construct new entrance lodge and access road – Construct new Junior School – Extend existing car park
Extend car park New Security Entrance Lodge Construct new Junior School
Design: 15 months Planning: 3 months Procurement: 6 months Construction: 15 months Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 5 – Relocate Junior School to new building – Demolish old Junior School
Demolish Junior School
Procurement: 3 months Demolition: 3 months
Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 6 – Extend boarding house – Construct new dining hall
Construct new Dining Hall
Extend Boarding House
Design: 15 months Planning: 3 months Procurement: 6 months Construction: 15 months Hawkins\Brown © | City of London Freemen's School
Masterplan Proposal Phase 7 – Demolish Assembly Hall
Demolish Assembly Hall
Procurement: 3 months Demolition: 3 months
Hawkins\Brown Š | City of London Freemen's School
Masterplan Proposal Phase 8 – Construct new Assembly Hall
Construct new Assembly Hall
Design: 15 months Planning: 3 months Procurement: 6 months Construction: 15 months Hawkins\Brown Š | City of London Freemen's School
Main House Vision
– Create new contemporary sixth form facilities in keeping with Grade II* listed house – Offer the best teaching and learning provision for pupils at the school – Consider what the future of education might look like in the 21st Century – Provide flexible environments that respond to educational change and foster collaborative working and independent thought Hawkins\Brown © | City of London Freemen's School
Main House Brief
– New sixth form centre – New kitchen and dining facilities – New teaching and learning spaces – Refurbished changing rooms – Independent Living Accommodation – Staff and support spaces – New energy Centre
Hawkins\Brown © | City of London Freemen's School
Working with Listed Buildings Neutral
Significant
Detracts
Age of Fabric
City of London Freemen’s School – Conservation Management Plan Some significance 2008
Ground floor
Age of Fabric
City of London Freemen’s School – Conservation Management Plan 2008
Age of Fabric
c. 1790
1939 - 1964
c. 1790 fabric removed
1964
c.1890 - 95
Post 1964
78
1924 - 1939 2.0 Understanding the Asset Age of Fabric
2.0 Understanding the Asset Age of Fabric
Key First and second floor
31 3.0 Assessment of Significance
Highly significant
Significance
Significance: Ground floor City of London Freemen’s School – Conservation Management Plan 2008
79
Age of Fabric
Ground Floor First and Significance second floor
Key First and second floor
c. 1790
1939 - 1964
c. 1790 fabric removed
1964
c.1890 - 95
Post 1964
Highly significant
c. 1790 fabric Significant removed Some significance
1907 - 1939
City of London Freemen’s School – Conservation Management Plan 2008
3.0 Assessment of Significance
c.1890 - 95
29
alan baxter
1924&- associates 1939
alan baxter & associates
Significance
Ground Floor First and second floor
1939 - 1964 Neutral
1964Detracts Post 1964 City of London Freemen’s School – Conservation Management Plan 2008
c. 1790
1929 - 1939
c. 1790 fabric removed
1939 - 1964
c.1890 - 95
1964
1924 - 1929
Post 1964
31
3.0 Assessment of Significance
c. 1790
City of London Freemen’s School – Conservation Management Plan 2008
Hawkins\Brown © | City of London Freemen's School
Principal Rooms
Hawkins\Brown © | City of London Freemen's School
Strip out Historic Adaptions
Hawkins\Brown © | City of London Freemen's School
Addressing Building Issues
Hawkins\Brown © | City of London Freemen's School
18
19
20
21
22
Teaching and Learning 17 18 19 Spaces 20 18
19
20
21
22
P00 For Information Description into it omissions that Rev may have been incorporated P01 Work In Progress P00 For Information as a result of incorrect information provided to the P02 Stage 2 P01 Work In Progress Architect. Those relying on this drawing are P03 Stage 2 Addendum P02 Stage 2 advised to obtain verification of its P03 independent Stage 2 Addendum accuracy.
23
21
22
23
Rev P00 P01 P02 P03
23
UP
UP
Description For Information Work In Progress Stage 2 Stage 2 Addendum
Date 27/01/17 03/03/17 12/05/17 21/07/17
Date 27/01/17 03/03/17 12/05/17 21/07/17
UP UP
UP
GFW6 Inner Hall 37.84 m²
SFG1.1 Project Room 15.06 m²
GFW7 Independent Study 59.42 m²
SFG1.2 Project Room 14.62 m²
GFW8 Sixth Form Common Room 138.00 m²
SFG4 Project Room 39.05 m²
GFW7 Independent Study SFG2 Independent Learning 59.42 m² 42.94 m²
GFW8
UPSixth Form Common Room 138.00 m²
SFGA Circ. 9.34 m²
SFG3 Stairwell 20.56 m²
GFW12.1 Stair 03 29.93 m²
UP
UP
SFGB.2 well/Circulation GFW13 Hall 28.74Entrance m² 48.25 m²
GFW12.1 Stair 03 29.93 m²
SFGC Circ. 16.78 m²
UP
GFW11 Library 51.67 m²
SFGC.3 Circulation 1.13 m²
SFGF Circ. 4.94 m²
UP
SFGC.4 Circ. 6.78 m²
SFGC.1 Circ. 8.96 m²
SFG5 Quiet Space 10.43 m²
UP
GFW11 Library 51.67 m²
SFG9 WC 15.28 m²
SFG8 WC 15.57 m²
SFG10 Project Room 11.89 m²
GFW10 SFG6 ?Loggia 33.39 33.90 m² m²
SFG7 Meeting Room 16.66 m²
GFW10 Loggia 33.39 m²
om
UP
UP
UP
UP
UP
G UP
16
F
UP
F G
H J
16
17
17
Project
Project
CoLFS - Main House CoLFS - Main House Ashtead Park Ashtead Park Ashtead Ashtead Surrey KT21 1ET Project Surrey KT21 1ET CoLFS - Main House Drawing Drawing Ashtead Park Proposed Second Floor Pla Ashtead Proposed Ground Floor Plan East Hawkins\Brown © | City of London Freemen's School Surrey KT21 1ET
15
16
17
18
19 20 21 22 Spaces 23 Teaching and Learning
19
P01 P02 P03
20
Work In Progress Stage 2 Stage 2 Addendum
21
22
03/03/17 12/05/17 21/07/17
23
UP
PLEASE NOTE: This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the accuracy of this drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy.
UP
UP
GFW5 Events Hall/Harkness 59.70 m²
17
GFW6 Inner Hall 37.84 m²
18
Rev P00 P01 P02 P03
GFW7 Independent Study 59.42 m²
19
20
21
22
contractor and such dimensions to be their responsibility. All work must comply with relevant British Standards and Building Regulations requirements. Drawing errors and omissions to be reported to the architect. To be read in conjunction with Architect's specification and other consultant information.
23
Description
Date 27/01/17 03/03/17 12/05/17 21/07/17
For Information Work In Progress Stage 2 Stage 2 Addendum
GFW8 Sixth Form Common Room 138.00 m²
SFG4 Project Room 39.05 m²
UP
SFG3 Stairwell 20.56 m²
SFGC.4 Circ. 6.78 m²
SFGC.1 Circ. 8.96 m²
GC.3 ulation 3 m²
UP
SFG1.2 Project Room 14.62 m² SFG7 Meeting Room 16.66 m²
UP
GFW12.1 Stair 03 29.93 m²
GFWD Stair 04 29.07 m²
UP
SFG5 Quiet Space 10.43 m² GFW13 Entrance Hall 48.25 m²
GFW15.1 Circulation 6.05 m²
GFW11 Library 51.67 m²
GFW14 Head of 6th Form 31.47 m²
GFW15 DDA WC / Baby Change SFG6 9.16 m² ? SFG2 33.90 m² Independent Learning 42.94 m²
SFG4 Project Room 39.05 m²
GFW10 Loggia 33.39 m²
UP
SFG3 Stairwell 20.56 m²
²
UP
SFGC Circ. 16.78 m²
SFGC.3 Circulation 1.13 m²
UP
SFGC.4 Circ. 6.78 m²
SFGC.1 Circ. 8.96 m²
SFG5 Quiet Space 10.43 m²
UP UP
UP
UP
SFGF Circ. 4.94 m² SFG9 WC 15.28 m²
SFG10 Project Room 11.89 m²
ks East
SFG8 WC 15.57 m²
SFG6 ? 33.90 m² SFG7 Meeting Room 16.66 m²
Project
CoLFS - Main House Ashtead Park F Ashtead Surrey KT21 1ET G
16
17
Drawing
Proposed Second Floor Plan H Hawkins\Brown © | City of London Freemen's School J
This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the accuracy of this drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy.
Social and Dining Spaces 20
21
22
Rev P00 P01 P02 P03
23
Description For Information Work In Progress Stage 2 Stage 2 Addendum
Date 27/01/17 03/03/17 12/05/17 21/07/17
UP
UP
GFW7 Independent Study 59.42 m²
GFW8 Sixth Form Common Room 138.00 m²
UP
GFW11 Library 51.67 m²
GFW10 Loggia 33.39 m²
UP
UP
F
16
17
Project
CoLFS - Main House Ashtead Park
Hawkins\Brown © | City of London Freemen's School
Copyright Hawkins\Brown Architects No implied licence exists. This drawing should not be used to calculate areas for the purposes of valuation. Do not scale this drawing. All dimensions to be checked on the site by the contractor and such dimensions to be their responsibility. All work must comply with relevant British Standards and Building Regulations requirements. Drawing errors and omissions to be reported to the architect. To be read in conjunction with Architect's specification and other consultant information.
Independent Living
– 4no 2- bed rooms for short term 07 08 09 10 11 12 stays under supervision
13
14
PLEASE NOTE: This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the accuracy of this drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy. Rev P00 P01
Description For Information Work In Progress
Date 27.01.17 03.03.17
– Allow pupils to experience independence and develop life skills in a safe, secure enivironment
2P Dorm
Ensuite
17 m²
9 m²
2P Dorm
FFL 98850.00
FFL 98850.00
25 m²
Kitchen/Dining 52 m²
FFL 98850.00
Stair 1 11 m²
DN
FFL 98850.00
Circulation
Circulation
21 m²
Refuge
15 m²
WC 4 m²
Grad Assistant/Accessible
Ensuite 7 m²
DN
2P Dorm 22 m²
18 m²
Stair 6 28 m²
FFL 97210.00 FFL 95670.00
FFL 98850.00
FFL 98850.00
2P Dorm 16 m²
Ensuite 9 m²
Project
CoLFS - Main House Ashtead Park Ashtead Surrey KT21 1ET Drawing
Hawkins\Brown © | City of London Freemen's School
Uncovering history - The Orangery
Copyright Hawkins\Brown Architects No implied licence exists. This drawing be used to calculate areas for the purpo valuation. Do not scale this drawing. All dimensions to be checked on the site by contractor and such dimensions to be th responsibility. All work must comply with British Standards and Building Regulatio requirements. Drawing errors and omiss reported to the architect. To be read in conjunction with Architect's specification consultant information.
Key:
Copyright Hawkins\Brown Architects No implied licence exists. This drawing should not be used to calculate areas for the purposes of valuation. Do not scale this drawing. All dimensions to be checked on the site by the contractor and such dimensions to be their responsibility. All work must comply with relevant British Standards and Building Regulations requirements. Drawing errors and omissions to be reported to the architect. To be read in conjunction with Architect's specification and other consultant information.
Accommodation
Administration & School Staff Bathrooms & WC Catering Changing Facilities Circulation Entertainment
15
16
17
Estates Management Kitchen/Dining
18
19
15
Services
20
16
21
22
17
23 19
18
20
21
22
23
Rev P00
Description
PLEASE NOTE: This drawing was prepared, in part, bas survey information provided by others. survey information is believed to be reli Architect assumes no responsibility for accuracy of this drawing or for any erro omissions that may have been incorpor as a result of incorrect information prov Architect. Those relying on this drawin advised to obtain independent verificati accuracy.
Date 27.01.201 7
For Information
Sixth Form Store Teaching
Rev P00 P01
A
Description For Information Work In Progress
UP
1 24-002
B
1 00-0165
UP
C D
Inner Hall 37 m²
8 Dining 59 m²
7
Sixth Form Common Room 37p
2
07-0013 5 1
6 74-001
Events Hall/Harkness 15p
2
Inner Hall
59 m²
74-001
24-002
37 m²
131 m²
Independent Study 18p 58 m²
FFL 95380.00
E
FFL 95380.00
FFL 95380.00
FFL 95450.00
---
F G
Stair 04
FFL 95380.00
24 m²
UP
H
Entrance Hall
31 m²
Teaching Room
UP
Stair 03
51 m²
Corridor 3 m²
K 1
1
00-0163
00-0164
9 m²
5
74-001
1925
Library 20p
Entrance Hall
07-0012 3
51 m²
47 m²
DN
4 Head of 6th Form
DN
FFL 95380.00
1
31 m²
11 m²
M
3
UP
30 m²
FFL 95380.00
WC 9 m² Office Admin
Male WC
FFL 95450.00
2
Corridor 6 m²
00-0161 FFL 95380.00
FFL 95380.00
FFL 95380.00 FFL 95450.00
Loggia 34 m²
N O P Q
00-0154
FFL 95380.00
25 m²
47 m²
J
Headmaster's Secretary's Office
1
Stair 04
Stair 03 18 m² UP
PLEASE NOTE: This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the accuracy of this drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy.
15
1 00-0162
16
17
F Refer to 00-0123
1929 1 loggia marble floors
2000's subdivision raised floor added
02 Ground Floor - PH1 Prop Works East 1 : 100
15
16
F
G H
UP
DN
Current Proposal subdivision floor reinstated
H
DN
Stair 04 25 m²
Project
J CoLFS - Main House Ashtead K Park Ashtead Surrey KT21 1ET 1 1 Drawing
N
00-0163
WC
17 m²
Present Day Date
1 : 100
Drawn By
01/16/17
2
02 Ground Floor Mezz - PH1 Prop Works Checked By 1 : 100 SS
M
SS
N
Job Number
Status
Purpose of Issue
1692
S2
Stage 2
1 : 100
Proposed Ground Floor Pl
00-0164
Scale O @ A1
L 00-0160 00-0161
02 Ground Floor Mezz
Project
CoLFS - Main House Ashtead Park Ashtead Surrey KT21 1ET Drawing
17 m²
WC
1
2
UP
Existing M Plan - Ground Floor (Part 2)
J K
G
WORK IN PROGRESS
Drawing No.
Scale @ A1
Date
1 : 100
01/17/17
Drawn By
Checked By
SS
SS
Job Number
Status
Purpose of
HB1692
WORK IN PROGRESS
Drawing No.
FMH-HBL-ZZ-00-DR-A-00-012
Rev Hawkins\Brown © | City of London Freemen's School
FMH-HBA-ZZ-00-DR-A-00-0104
Celebrating Heritage - Minton Tiled Bathrooms
14
15
16
17
17
18
18 19
19 20
20 21
22
21 23
22
23
Copyright Hawkins\Brown Architects Copyright Hawkins\Brown Architects No implied licence exists. This drawing should not be should used tonot calculate areas for the purposes of No implied licence exists. This drawing valuation. be used to calculate areas for the purposes of Do not scale this drawing. All dimensions to be checked on the site by the valuation. Do not scale this drawing. All dimensions to be checked on the sitecontractor by the and such dimensions to be their responsibility. All work must comply with relevant contractor and such dimensions to be their British Standards and Building Regulations responsibility. All work must comply with relevant requirements. Drawing errors and omissions to be British Standards and Building Regulations reportedtotobe the architect. To be read in requirements. Drawing errors and omissions with Architect's specification and other reported to the architect. To be read conjunction in consultant information. conjunction with Architect's specification and other consultant information. PLEASE NOTE: This drawing was prepared, in part, based on PLEASE NOTE: surveyon information provided by others. While this This drawing was prepared, in part, based survey information is believed to be reliable, the survey information provided by others. While this Architectthe assumes no responsibility for the survey information is believed to be reliable, accuracy of this drawing or for any errors or Architect assumes no responsibility for the omissions that may have been incorporated into it accuracy of this drawing or for any errors or as a result omissions that may have been incorporated intoofit incorrect information provided to the Architect. Those relying on this drawing are as a result of incorrect information provided to the advised Architect. Those relying on this drawing are to obtain independent verification of its accuracy. advised to obtain independent verification of its accuracy.
Indicative area for reuse of B.Finch & Co Ltd interlinked wash basins. Proposed vitrine cubicle
Minton tiled wall
Rev P00 P01
Project Room (6 person capacity) 15 m² Independent Learning (25 Pupils)
Project Room (8 person capacity) 21 m²
Description For Information Work In Progress
Rev P00 P01
Description
For Information Date Work In Progress 27.01.17 03.03.17
Date 27.01.17 03.03.17
Project Room (2-3 person capacity) 15 m²
42 m²
Harkness Room Independent (12(25 person Learning capacity) Pupils)
Office 15 m²
FFL 105400.00 FFL 105400.00
UP Stairwell
FFL 100850.00
20 m²
15 m²
Project Room (12 Pupils) 39 m²
FFL 105400.00
FFL 100850.00 FFL 105400.00
Circulation 9 m²
Catering Office
Stairwell
43 m² 39 m²
Circulation 5 m²
5 m²
DN DN Stairwell/Circulation
ell
28 m²
Display Zone
Display Zone UP
17 m²
6 m²
Display Zone/Stairwell 31 m²
Circulation
Circulation Display Zone 17 m²
Store
4 m² FFL 105400.00
10 m²
Office/Store 17 m²
FFL 105400.00
12 m²
DN
Harkness Room (12 person capacity)
Teaching Room (35 Pupils)
Circulation
35 m²
5 m²
WC
16 m²
Meeting Room 17 m²
FFL 105400.00
33 m²
WC
14 m²
Project Room (2-3 person capacity)
WC
WC
15 m²
15 m²
12 m²
FFL 105400.00
Teaching Room (35 Pupils) 34 m²
FFL 105400.00 FFL 100850.00
Deputy Head 11 m²
Project
Project
CoLFS - Main House Ashtead Park Ashtead Surrey KT21 1ET Drawing
CoLFS - Main House Ashtead Park Ashtead Surrey KT21 1ET Drawing
Hawkins\Brown © | City of London Freemen's School
Copyright Hawkins\Brown Architects No implied licence exists. This drawing should not be used to calculate areas for the purposes of valuation. Do not scale this drawing. All dimensions to be checked on the site by the contractor and such dimensions to be their responsibility. All work must comply with relevant British Standards and Building Regulations requirements. Drawing errors and omissions to be reported to the architect. To be read in conjunction with Architect's specification and other consultant information.
Basement Plan 01
02
03
04
05 06
07
08
09
11 11
10
12 12
13 13
14
15
16
PLEASE NOTE: This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the 17 accuracy of this drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy. Rev P00 P01
DN
19
20
FFL 92150.00
B
FFL 92090.00
UP
UP DN
C DN
DN
614.23
38 m²
FFL 92580.00
IT /Reprographics Office
FFL 92090.00
DN
D
Archives Room
Wine Store 20 m²
Staff Changing Room 18 m²
29 m²
IT/Reprographics Office 47 m²
FFL 92210.00
Staff Changing Room
FFL 92210.00
UP
FFL 92540.00
Corridor/Circulation from Changing Room
Store 54 m²
Changing 01
14 m²
68 m²
22 m²
Changing 02 51 m²
FFL 92150.00
FFL 92150.00
FFL 92150.00
E
FFL 92540.00
Store 22 m²
Corridor 14 m²
Corridor 3 m²
F G
Circulation
30 m²
6 m²
Corridor
H
DN
Circulation
9 m²
Corridor
17 m²
FFL 92150.00
Corridor
Corridor
26 m²
Circulation
15 m²
Circulation
FFL 92150.00
23 m²
18 m²
Lift Car
Refuge
J
40 m²
FFL 92230.00
Plant Room 17 m²
FFL 91860.00
Kitchenette 3 m²
Stair 06 26 m²
WC
14 m²
CCF Storage (Armoury Store)
Key:
Estates Office
FFL 91860.00
Stair 05 9 m²
FFL 92230.00
Plant Room 10 m²
FFL 92150.00
UP
K CCF
Visitor Changing Room
Circulation 16 m²
3 Main House Proposals 3.5 General Arrangement Plans and Proposals 3.5.1 Sub-Basement
Accommodation
M
Administration & School Staff
N O P
Catering
Visitor Changing Room
DN
3 m²
Q
Project
CoLFS - Main House Ashtead Park Ashtead Surrey KT21 1ET
Refer to 00-0121
Circulation Entertainment Estates Management Kitchen/Dining Services Sixth Form Store Teaching Calculating...
Drawing
Proposed Basement Floor Plan West
Store Administration & School Staff
Changing Facilities
Refurbished changing rooms 01 Basement Prop Works East New IT- PH1 workshops New office spaces Energy Centre 09 PROGRESS NewWORK LiftINand stairs Sixth Form Storage Refer to 00-0122
Accommodation Sixth Form
Catering
FFL 92150.00
Visitor Changing Room
Services
Bathrooms & WC Teaching
31 m²
FFL 92150.00
UP
Estates Management
Key:
FFL 92150.00
6th Form Bag Store
46 m²
Entertainment
Kitchen/Dining
Store 17 m²
FFL 92150.00
Circulation
1 : 100
30 m²
45 m²
UP
Changing Facilities
01 Basement - PH1 Prop Works West
Sixth Form Lockers & Bag Store
Visitor Changing Room
21 m²
28 m²
13 m²
Bathrooms & WC
1
21
Date 27.01.17 03.03.17
For Information Work In Progress
A
DN
Energy Centre
Description
18
1
1 : 100
Scale @ A1
Date
1 : 100
01/17/17
Drawn By
Checked By
SS
SS
Job Number
Status
WORK IN PROGRESS
Purpose of Issue
HB1692
Drawing No.
Rev
FMH-HBA-00-B1-DR-A-00-0121
P01
10
11
5 74-001
12
C D
IT Server Room
E
09
Hawkins\Brown © | City 10 11 12 of London Freemen's School 37 m²
FFL 89710.00
Ground Floor Plan
01
02
03
04
05 06
Copyright Hawkins\Brown Architects No implied licence exists. This drawing should not be used to calculate areas for the purposes of valuation. Do not scale this drawing. All dimensions to be checked on the site by the contractor and such dimensions to be their responsibility. All work must comply with relevant British Standards and Building Regulations requirements. Drawing errors and omissions to be reported to the architect. To be read in conjunction with Architect's specification and other consultant information.
07
08
09
10
11
12
13
15 15
14
PLEASE NOTE: This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the accuracy of this drawing or for any errors or 17 18it omissions that may have been incorporated into as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy.
16
Rev P00 P01
Description
19
20
21
22
23
Date 27.01.17 03.03.17
For Information Work In Progress
A
B C D FFL 95360.00 FFL 95440.00
Events Hall/Harkness 15p
Kitchen 17 m²
Kitchen (Reheat facility)
FFL 95380.00
G FFL 95440.00 Circulation
H
K
FFL 96467.46
FFL 96551.79 FFL 96391.28
FFL 95440.00
Key: UP
Stair 05
FFL 96416.80
12 m²
P
Kitchen Store
27 m²
14 m²
WC
13 m²
Stair 04
FFL 95450.00
Stair 03
UP
Accommodation
Administration & School Staff
Bathrooms & WC Catering
UP
30 m²
Corridor Corridor 33m² m²
51 m²
47 m²
6 m² 6 m²
FFL 95360.00
Library 20p
Entrance Hall
Corridor Corridor FFL 95380.00
DN
FFL 95380.00
Female (Pupil) WC 26 m²
Male (Pupil) WC
Head of 6th Form
18 m²
31 m²
WC 9 m²
3 Main House Proposals 3.5 General Arrangement Plans and Proposals 3.5.1 Sub-Basement FFL 95440.00
FFL 95450.00
FFL 95380.00
25 m²
188 m²
J
Refuge 41 m²
FFL 95380.00
Events Hall 96p
47 m²
Stair 01
FFL 95380.00
FFL 95380.00
F
G
Marketing
Independent Study 18p 58 m²
E DN
DN
131 m²
37 m²
37 m²
UP
FFL 96939.14
Inner Hall
59 m²
Servery
47 m²
FFL 97057.10
Sixth Form Common Room 37p
FFL 95440.00
FFL 95440.00
WC
M N O P
FFL 95380.00
FFL 95380.00
FFL 9 m²95380.00
FFL 95450.00
Q
F
Refer to 00-0123
Circulation
G
Refer to 00-0124
Entertainment
Project
Estates Management
Key:
Services
Accommodation Sixth Form
1
02 Ground Floor - PH1 Prop Works West 1 : 100
Store Administration & School Staff
Bathrooms & WC Teaching Catering Changing Facilities Circulation Entertainment Estates Management Kitchen/Dining Services Sixth Form Store Teaching Calculating...
34 m²
FFL 95540.00
Changing Facilities
Kitchen/Dining
Loggia
1
02 Ground Floor - PH1 Prop
CoLFS - Main House Ashtead Park Ashtead Works East Surrey KT21 1ET
H
New (compact) kitchen facilities Sixth Form Dining Room Sixth Form Common Room Teaching Facilities 09 10 11 Library WORK IN PROGRESS Reinstated Loggia Improved C Approach/entry 1 : 100
J K
Drawing
Proposed Ground Floor Plan West
M
Scale @ A1
Date
1 : 100
01/17/17
N
Drawn By
Checked By
SS
SS
O
Job Number
Status
Purpose of Issue
HB1692
Drawing No.
Rev
FMH-HBL-ZZ-00-DR-A-00-0123
P01
5 74-001
12
D
Hawkins\Brown © | City of London Freemen's School IT Server Room 37 m²
2
0
1
Copyright Hawkins\Brown Architects No implied licence exists. This drawing should not be used to calculate areas for the purposes of valuation. Do not scale this drawing. All dimensions to be checked on the site by the contractor and such dimensions to be their responsibility. All work must comply with relevant British Standards and Building Regulations requirements. Drawing errors and omissions to be reported to the architect. To be read in 17 conjunction with Architect's specification and other consultant information.
First Floor Plan 12
01
02
03
04
05 06
07
08
09
10
11
12
13
13
14
15
16
A
B
B
C
C
D
D
19
20
21
22
23
PLEASE NOTE: This drawing was prepared, in part, based on survey information provided by others. While this survey information is believed to be reliable, the Architect assumes no responsibility for the accuracy of this drawing or for any errors or omissions that may have been incorporated into it as a result of incorrect information provided to the Architect. Those relying on this drawing are advised to obtain independent verification of its accuracy.
14
Rev P00 P01
A
18
Description
Date 27.01.17 03.03.17
For Information Work In Progress
Independent Learning (25 Pupils) 42 m²
2P Dorm
Ensuite
17 m²
Staff Room
6 m²
2P Dorm
FFL 98850.00
15 m²
39 m²
UP Stairwell
FFL 100850.00
25 m²
Harkness Room (12 person capacity)
Office
39 m²
FFL 100850.00
FFL 100850.00
20 m²
E
FFL 98850.00
E
Kitchen/Dining 52 m²
11 m²
F Circulation
24 m²
4 m²
Grad Assistant/Accessible
Ensuite 7 m²
18 m²
Key:
DN
G
FFL 103193.94
Stairwell 21 m²
H
Display Zone/Stairwell
Display Zone
Display Zone
17 m²
6 m²
UP
Display Zone
Teaching Room (35 Pupils) 35 m²
K
2P Dorm 22 m²
WC
WC
16 m²
28 m²
14 m²
3 Main House Proposals 3.5 General Arrangement Plans and Proposals 3.5.1 Sub-Basement FFL 97210.00
FFL 98850.00
Ensuite
Accommodation
N
Administration & School Staff
P
Bathrooms & WC
Q
Catering
9 m²
Changing Facilities
FFL 98850.00
Harkness Room (12 person capacity)
2P Dorm 16 m²
FFL 100850.00
M
Deputy Head 11 m²
N O P Q
Project
CoLFS - Main House Ashtead Park Ashtead Surrey KT21 1ET
Entertainment Estates Management
Key:
Kitchen/Dining
Drawing
Services
Proposed First Floor Bursary Plan
Accommodation Sixth Form Store Administration & School Staff
Bathrooms & WC Teaching Catering Changing Facilities
Entertainment Estates Management Kitchen/Dining Services Sixth Form Store
FFL 100850.00
39 m²
Circulation
Circulation
12 m²
DN
Stair 6
FFL 95670.00
Store
4 m²
31 m²
J
WC
DN
M
Circulation
15 m²
Refuge
K
5 m²
F
DN
FFL 98850.00
H
Catering Office
FFL 98850.00
Stair 1
1
Independent Living Teaching Facilities 03 First Floor - PH1 PropNew Works lift and stair core (West Wing) New staircase 09connection to main stair WORK IN PROGRESS 10 11 12 New WC’s to Minton Tiled Rooms 1 : 100
Scale @ A1
Date
1 : 100
01/13/17
Drawn By
Checked By
SS
SS
Job Number
Status
Purpose of Issue
HB1692
S2
Stage 2
Drawing No.
Rev
5
FMH-HBA-00-01-DR-A-00-0126
P01
74-001
WORK IN
Teaching Calculating...
C D
Hawkins\Brown IT©Server | City Room of London Freemen's School E
09
10
11
37 m²
12
Second Floor Plan
12
13
14
15
16
17
18
19
20
21
22
23
A
B C Project Room (8 person capacity)
D
Project Room (6 person capacity) 15 m²
21 m²
Project Room (2-3 person capacity) 15 m²
Independent Learning (25 Pupils)
FFL 105400.00
Stairwell 15 m²
43 m²
FFL 105400.00
39 m²
FFL 105400.00
FFL 105400.00
E
Project Room (12 Pupils)
Circulation 9 m²
Circulation 5 m²
F DN
G Stairwell/Circulation
H
Office/Store
Circulation
Circulation
28 m²
17 m²
10 m²
17 m²
FFL 105400.00
FFL 105400.00
J Harkness Room (12 person capacity)
K
Circulation
Meeting Room
5 m²
17 m²
FFL 105400.00
33 m²
Project Room (2-3 person capacity)
Key:
Teaching Room (35 Pupils)
WC
WC
15 m²
15 m²
34 m²
12 m²
3 Main House Proposals 3.5 General Arrangement Plans and Proposals 3.5.1 Sub-Basement M
Accommodation
Administration & School Staff
Bathrooms & WC Catering
FFL 105400.00
FFL 105400.00
N O P Q
Changing Facilities Circulation Entertainment
Estates Management
Key:
Kitchen/Dining Services
Accommodation Sixth Form Store Administration & School Staff
Bathrooms & WC Teaching Catering Changing Facilities Circulation Entertainment Estates Management Kitchen/Dining
1
New Teaching Facilities 04 Second Floor - PH1 Prop Works New staircase connection to main stair New WC’s to Minton Tiled Rooms 1 : 100
09
Services
10
11
5 74-001
12
WORK IN PROGRE
Sixth Form Store Teaching Calculating...
C D
Hawkins\Brown IT©Server | City Room of London Freemen's School E
09
10
11
37 m²
12
Developing Designs - precedents/building visits/consultation
Hawkins\Brown Š | City of London Freemen's School
Thank you
Any questions?