s
cables
S
FS
FS Cables Front Cover*:Layout 1
18/11/10
15:33
Page 1
the little
FS
red book
Issue 10
cables
the little red book
FS
cables
FS
FS
FS
FS
FS
Issue 10
FS Cables Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX
cables
cables
cables
cables
cables
flexible and FSspecialist FS cables cables
FS Cables
Tel: 01727 840 841 Fax: 01727 840 842 www.fscables.com sales@fscables.com
cables
How to Order:
Payment Options:
By phone
Apply for a credit account
01727 840 841
Please ask your sales contact or visit the website for an account application form
By fax
01727 840 842 By email
By payment card
sales@fscables.com
We accept most major credit, debit and purchasing cards
Our hours are
Mon-Fri 8am to 6pm
Delivery Options: •
Next working-day delivery is standard to mainland UK, free on orders over £100
•
No cut-off time for orders – if we can ship it, we will
•
Same-day deliveries, distance and time permitting
Express Delivery Options for Parcels and Small Drums: Pre 9.00am / Pre 10.30am / Pre 12pm and next working-day service available Pre 10.30am / Pre 12pm and next working-day service available Pre 12pm and next working-day service available Next working-day service only
2-3 day service – please check at time of order. Surcharges apply. Note pallet services differ slightly, with the earliest delivery option being Pre 10.30am.
Many of the cables listed on the following pages would be regarded as specialist within the electrical industry. We regard them as standard. To support this we hold many of them in stock for immediate despatch and in many cases, cut to the length you require – keeping your costs down and reducing the environmental impact through reduced wastage. With constant pressure to keep prices as low as possible it is essential to maintain quality and standards and this has become our mission. The products offered are designed to do the job – your job. Our commitment to service means you’ll receive goods where and when you need them. With stock items there is no order cut-off time, if we can ship it we will. Next working-day delivery to UK mainland is standard. For special and modified products we offer realistic lead times and sensible minimum order quantities. Many stock products can also be modified to meet specific requirements, for example armouring, oversheathing or duct grade for exterior use. Quantities on these can often be as low as 100m. Please see pages 152-153 for more information.
www.fscables.com
DATA
06
COAXIAL
28
HOME AUTOMATION HD
40
BUS
42
AUDIO
49
FIRE & SECURITY
54
LONDON UNDERGROUND
62
TELEPHONE
64
SIGNAL & CONTROL
72
POWER CABLES
96
MARINE, OIL & GAS
102
RUBBER & CRANE
118
ROBOTICS
124
HIGH TEMPERATURE
130
THERMOCOUPLE
138
SPIRAL
142
GLANDS
144
TOOLS
148
SPECIAL MANUFACTURE
152
TECHNICAL TABLES
154
COLOUR CODES
166
4
SERVICE & SUPPORT Same Day Dispatch There is no cut off time for orders received, if we can ship your order we will. For really urgent orders we can courier goods sameday into and around London, time permitting. Modern Warehousing Facility Over 55,000sq ft. of modern warehouse space featuring large, secure loading and unloading facilities and a full size weighbridge. Commitment to Stock Approximately 3000 product lines are held in stock for next working-day delivery, free on orders over £100. Dedicated Export Department Our export team FSC Global are on hand to handle overseas enquiries. Custom Manufacture If you need a cable manufactured to your own specification or standard – talk to us. This can range from a printed or coloured jacket, right down to composite cables containing multiple elements. Armouring and Over-Sheathing Over-sheathing or steel wire armouring (SWA) to an existing cable with short lead times and for quantities as low as 100m. Cut to Length
cables
FS
FS
We cut to length on many product lines meaning you only buy what you need – reducing both your costs and wastage. Order Call-Off Place an order and ‘call it off’ over time as required from our warehouse for just in time deliveries. This both fixes your costs and guarantees supply.
cables
How to find us cables
FS
FS cables
FS Cables are based on Alban Park in St. Albans near J3 of the A1(M) or J22 of M25. If using Sat-Nav please use the postcode AL4 0JJ. Full turn by turn directions are available on the website www.fscables.com/map
www.fscables.com
sales@fscables.com
5
HOW TO USE THIS CATALOGUE
Many of the products listed in this catalogue are available in Low Smoke Halogen Free (LSHF), duct grade or SWA versions. These products are clearly indicated on each page using this key: Low Smoke Halogen Free
Duct Grade
SWA
Low Smoke Halogen Free Low Smoke Halogen Free cables are those which emit minimal levels of toxic fumes and smoke in the event of fire. It does not refer specifically to one particular type of material. They are ideal for installations in confined areas such as computer rooms and other sensitive environments, or areas that may be difficult to evacuate in the event of fire such as airports, hospitals or tube stations. Standard PVC cables are made up of halogens which, when burnt, give off toxic gases such as hydrogen chloride. When exposed to water – moisture in the air or fire sprinkler systems for example, hydrogen chloride forms highly noxious and corrosive hydrochloric acid. Specifying Low Smoke Halogen Free (LSHF) cable goes a long way to reducing this risk.
3m³ smoke test to IEC 61034
Compared to standard PVC which emits around 28% acid gas, LSHF cables produce less than 0.5% HCl (Gases Evolved During Combustion BS EN 50267, IEC 60754-2). Visibility through smoke emission is measured through a 3m³ smoke test (pictured) to IEC 61034. Most LSHF cables produce very little smoke as opposed to standard PVC which gives off dense black smoke. Confusion still surrounds the terminology used to describe LSHF cables. While LSHF, LS0H, LSZH and 0HLS are the same, LSF (Low Smoke & Fume) is not. LSF covers data, control and flexible cables and is normally significantly inferior. LSF cables are often modified PVC compounds and can still emit up to 22% HCl. They should be regarded as only slightly better than PVC in the event of fire. The LSF cables in this catalogue can be regarded as better than standard PVC but are not halogen free. If you are unsure of what you are buying, ask for written confirmation that the cable is LSHF throughout. At FS Cables, when you select LSHF, you can be confident you are buying a high quality Low Smoke Halogen Free cable.
FS
cables
FS
FS
FS
FS
FS
cables
FS
cables
FS Where all the products on a page are LSHF they are indicated with this header.
Duct Grade Duct grade cables feature a tough, water resistant polyethylene (PE) jacket normally over the standard jacket. They are suited for external installations where the cable may be run through ducts or clipped to buildings. They also offer excellent UV resistance.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
SWA cables are ideal for fixed external installations or direct burial or where mechanical protection is required. The cable features protective steel armour wires and a PE, external grade PVC or Low Smoke Halogen Free outer jacket over the duct grade cable above.
cables
SWA
cables
cables
6 Belden No.
1048AH 1215A 1502RHDA 1588AH 3076FHA 3077FHA 3078FHA 3079AHDA 3079E 3082A 3083AA 3084A 3085AA 3102A 3119A 7701H 7702H 7703H 7704H 8102H 8103H 8104 8105 8106H 8107 8108H 8110 8112 8115 8118 8125 8132H 8133H 8162HL 8163HL 8164H 8166 8167H 8168 8170 8175 8178 8185 cables 8205HL 8312 8325 8345 8355 8442HL 8444H 8451HL 8471HDAL cables
FS
FS
cables
FS
FS cables
DATA Belden Page Finder Page
21 22 46 24 42 42 42 45 45 43 43 43 43 44 44 44 44 44 44 17 17 17 17 17 17 17 17 17 17 17 17 56 56 18 18 18 18 18 18 18 18 18 18 7 DS DS DS DS 7 7 8 7, 44, 57
Belden No.
Page
8473HL 7 8618 9 8719HL 8 8720H 8 8723HDAL 12, 56, 60, 61 8728HL 12 8760HDL 8, 60 8761HDL 8 8762HDL 8 8769 13 8770HL 9 8771H 9 8772H 9 8773 13 8774H 13 8775 13 8776 13 8777HDAL 13, 56, 60, 61 8778HL 13 9156H 7 9182H 22 9207H 22 9248 DS 9272H 22 9363 21 9365 21 9368HL 19 9402HL 19 9418HL 10 9463H 22 9491 7 9501HDL 11, 60 9502HL 11 9503HDL 11, 60 9504HDL 11, 60 9505HL 11 9506HL 11, 60 9507H 11 9508HL 11 9509 11 9510HL 11 9515H 11 9519HL 11 9525HL 11 9533L 10 9534HL 10 9535L 10 9536HL 10 9537 10 9538HL 10 9539 10 9891 22
Belden No.
Page
9540HL 10 9541HL 10 9542 10 9543 10 9544 10 9545 10 9546 10 9550 11 9688H 22 9696 DS 9728H 14 9729HDAL 14, 60, 61 9730HL 14 9731H 14 9732 14 9733 14 9734 14 9735 14 9736 14 9737 14 9738 14 9740HL 7 9744H 7 9750H 7 9767 13 9768H 13 9769 13 9773H 19 9774H 19 9829H 20 9830 20 9831 20 9832 20 9833 20 9834 20 9835 20 9836 20 9837 20 9838 20 9839 20 9841HDAL 15, 45 9842HDAL 15, 56, 60, 61 9843H 15 9844H 15 9860 22 9873HL 19 9874 19 9875 19 9876 19 9877 19 9879 19 9880 22
Belden No.
Page
9901H 9907H 9913 9925 9927 9929 9931 9932 9933 9934 9935 9936 9937 9938 9939 9940 9941 9942 9943 9944 9945 9946 9947 9948 9949 9950 9990 9991 YM29560 YR47205
22 22 DS 16 16 16 16 16 16 16 16 16 16 16 20 20 20 20 20 20 20 20 20 20 20 20 DS DS 45 43
Key
H = LSHF D = DUCT A = SWA L = LSF Details of cables listed as DS are available on a separate datasheet. LSF versions are available from stock where indicated In line with the rest of the industry our LSF cables are a modified PVC. If you need halogen free cables please specify LSHF.
FSC stock a wide range of genuine Belden cables and cost effective alternatives with PVC, Low Smoke Halogen Free and duct grade jackets. Armoured versions are also available from stock.
www.fscables.com
sales@fscables.com
7
Unscreened Pairs DATA Unscreened Paired Data Cable N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
General purpose unscreened single and multipair cables with a small outer diameter, frequently used in audio, bus, data, security and instrumentation applications. These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - Single Pair
Technical Information
Tinned copper stranded conductor, PVC insulation on
Voltage Rating:
22AWG -16AWG: 300V 14AWG:
standard cable, twisted into a pair, PVC sheath.
600V
CE: 450/750V† Colour Code:
Part No.
2201PUYL 2201PUYH 2001PUYL 2001PUYH 1801PUYL 1801PUYH 1601PUYL 1601PUYH 1401PUYL 1401PUYH
Alt. to Belden
No. of Pairs
AWG
CSA mm2
Weight kg/km
O/D mm
Capacitance C/C pF/m
8442 LSHF 8205 LSHF 9740 LSHF 8471 LSHF 8473 LSHF
1 1 1 1 1 1 1 1 1 1
22(7) 22(7) 20(7) 20(7) 18(16) 18(16) 16(19) 16(19) 14(42) 14(42)
0.35 0.35 0.56 0.56 0.79 0.79 1.34 1.34 2.01 2.01
23 23 26 26 37 37 56 56 89 89
4.5 4.5 5.0 5.0 6.0 6.0 7.0 7.0 8.5 8.5
99 99 81 81 84 84 108 108 108 108
Construction - Two & Three Pair
Technical Information
Tinned copper stranded conductor, PVC insulation, cores twisted into pairs, pairs laid together, clear tape, PVC sheath.
Voltage Rating:
9744 NH 9156 NH 9750 LSHF
No. of Pairs
AWG
2 2 3 3
22(7) 18(16) 20(7) 20(7)
Colour Code: CSA mm2
0.35 0.79 0.56 0.56
O/D mm
Capacitance C/C pF/m
39 71 67 67
6.2 8.5 7.6 7.6
84 84 80 80
Construction - Multicore
Technical Information
Tinned copper stranded conductor, PVC insulation, cores laid up, clear tape, PVC sheath.
Voltage Rating:
AWG
FS cables
CSA mm2
Weight kg/km
Chart 2 page 166 O/D mm
Capacitance C/C pF/m
FS
FS
FS
FS
9491
3
22(7)
0.35
32
4.9
85
8444 NH
4
22(7)
0.35
34
5.1
111
cables
2204CUYH
No. of Cores
FS
CE: 450/750V
cables
2203CUY
Alt. to Belden
FS
cables
300V
2204CUYH
†
Colour Code: Part No.
FS
Weight kg/km
cables
2202PUYH 1802PUYH 2003PUY 2003PUYH
Alt. to Belden
22AWG -16AWG: 300V 14AWG: 600V CE: 450/750V† Chart 3 page 166 cables
Part No.
1601PUYL
22AWG -18AWG: Black & red 16AWG -14AWG: Black & white
† Applies to CE marked FSC branded stock only
Low Smoke Halogen Free
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
8
DATA Screened Single Pair
Single Pair ScreenedXLPE/Cu/LSHF Data Cable Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV General purpose foil screened single pair cables with a small outer diameter, frequently used in audio, data and instrumentation applications. Polyethylene insulation results in lower signal loss than standard PVC insulation. These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - Screened Single Pair
Technical Information
Tinned copper conductor, polyethylene insulation,
Voltage Rating:
twisted pair, aluminium/polyester foil screen, tinned
300V
16AWG -14AWG:
600V
CE: 450/750V†
copper drain wire, PVC sheath. On duct grade cables
1601POFPL
22AWG -18AWG:
Temperature Rating: 22AWG - 18AWG: +60°C
an additional UV stable LDPE jacket is put over the
16AWG - 14AWG: +80°C
standard PVC cables to give a high degree of weather resistance.
UL Style*:
2092
Colour Code:
Black & clear (Black & white on LSHF cables)
Part No.
1801POFPD cables
FS
FS
Alt. to Belden
No. of Pairs
2201POFPL 8761 2201POFPH LSHF 2201POFPD DUCT 2001POFPL 8762 2001POFPH LSHF 2001POFPD DUCT 1801POFPL 8760 1801POFPH LSHF 1801POFPH06 VIOLET 1801POFPD DUCT 1601POFPL 8719 1601POFPH LSHF 1401POFP 8720 1401POFPH LSHF
1 1 1 1 1 1 1 1 1 1 1 1 1 1
AWG
22(7) 22(7) 22(7) 20(7) 20(7) 20(7) 18(16) 18(16) 18(16) 18(16) 16(19) 16(19) 14(19) 14(19)
CSA mm2
0.35 0.35 0.35 0.56 0.56 0.56 0.79 0.79 0.79 0.79 1.34 1.34 1.92 1.92
cables
cables
4.6 4.6 6.2 5.1 5.1 6.5 6.0 6.0 6.0 7.6 7.9 7.9 9.0 9.0
Technical Information
Tinned copper conductors, polypropylene insulation,
Voltage Rating:
copper drain wire, PVC sheath.
2201POFRL 2201POFRH
Alt. to Belden
8451 LSHF
No. of Pairs
1 1
AWG
22(7) 22(7)
CSA mm2
0.35 0.35
Capacitance pF/m C/C
C/S
79 79 79 89 89 89 79 79 79 79 75 75 79 79
154 154 154 161 161 161 144 144 144 144 144 144 154 154
300V CE: 450/750V†
twisted pair, aluminium/polyester foil screen tinned
Part No.
FS
25 25 27 35 35 38 45 45 45 48 84 84 109 109
O/D mm
Construction - Miniature 22AWG
cables
FS
Weight kg/km
Temperature Rating:
+75°C
Nominal Impedance:
45 Ohms
Colour Code:
Black & red
Weight kg/km
20 20
O/D mm
3.4 3.5
Capacitance pF/m C/C
C/S
111 111
220 220
† Applies to CE marked FSC branded stock only *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
Low Smoke Halogen Free
Duct Grade
www.fscables.com
sales@fscables.com
9
Screened Triple DATA Three Core Overall Screened Data Screened, Cable N2XCH-FE180/E90: XLPE/Cu/LSHF Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV For use as audio or instrumentation wiring.
Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 22AWG, 20AWG & 18AWG
Technical Information
Tinned copper conductor, polyethylene insulation, cores
Voltage Rating:
300V CE: 450/750V†
laid up, aluminium/polyester foil screen, tinned copper drain wire, PVC sheath.
Temperature Rating: UL Style*:
+60°C
Colour Code:
Black, red & clear
2093
1803COFPL Part No.
Alt. to Belden
No. of Cores
AWG
CSA mm2
Weight kg/km
O/D mm
Capacitance pF/m C/C C/S
3 3 3 3 3 3 3
22(7) 22(7) 22(7) 20(7) 20(7) 18(16) 18(16)
0.35 0.35 0.35 0.56 0.56 0.79 0.79
35 35 35 42 42 56 56
5.1 5.1 5.1 5.6 5.6 6.3 6.3
75 75 75 89 89 79 79
2203COFP 8771 2203COFPH LSHF 2203COFPH06 VIOLET 2003COFP 8772 2003COFPH LSHF 1803COFPL 8770 1803COFPH LSHF
134 134 134 167 167 157 157
Construction - 16AWG
Technical Information
Tinned copper conductor, polyethylene insulation,
Voltage Rating:
600V
cores laid up, aluminium/polyester foil screen, tinned
Temperature Rating:
+60°C
copper drain wire, PVC sheath.
UL Style:
2107
Colour Code:
Black, red & clear
No. of Cores
AWG
CSA mm2
Weight kg/km
O/D mm
1603COFP
8618
3
16(19)
1.34
96
8.3
Capacitance pF/m C/C C/S
85
2203COFPH06
FS
FS
FS
cables
FS
FS
FS
FS
FS
151
*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
Low Smoke Halogen Free
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
† Applies to CE marked FSC branded stock only
cables
Alt. to Belden
cables
Part No.
cables
10
DATA Overall Screened Multicores
Overall Screened Multicored Data Screened, Cable RS232 N2XCH-FE180/E90: XLPE/Cu/LSHF Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Uses include RS232, instrumentation and sound applications where balanced lines are not required. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 24AWG
Technical Information - 24AWG & 18AWG
Tinned copper conductor 24(7) AWG, 0.22mm2, PVC insulation. Cores laid up, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), PVC sheath.
Voltage Rating:
300V CE: 450/750V† Temperature Rating: +80°C Capacitance: Up to 8 core: Core to core 108pF/m, Core to screen 213pF/m Above 8 core: Core to core 98pF/m, Core to screen 180pF/m UL Style*: 2464 Colour Code: Up to 10 core Chart 1 page 166 Above 10 core Chart 2 page 166
2415COFYL
1804COFYL cables
FS
Part No.
Alt. to Belden
2403COFYL 2404COFYL 2404COFYH 2405COFYL 2406COFYL 2406COFYH 2407COFY 2408COFYL 2408COFYH 2409COFY 2410COFYL 2410COFYH 2415COFYL 2415COFYH 2420COFY 2425COFY 2430COFY 2440COFY 2450COFY
9533 9534 LSHF 9535 9536 LSHF 9537 9538 LSHF 9539 9540 LSHF 9541 LSHF 9542 9543 9544 9545 9546
No. of Cores
3 4 4 5 6 6 7 8 8 9 10 10 15 15 20 25 30 40 50
Weight kg/km
O/D mm
26 33 33 35 42 42 45 49 49 60 61 61 83 83 104 139 152 195 238
4.2 4.7 4.7 4.8 5.3 5.3 5.3 5.7 5.7 6.2 6.2 6.2 7.3 7.3 8.0 8.6 9.7 10.9 12.5
Construction - 18AWG
FS cables
cables
FS
Tinned copper conductor 18(19) AWG, 0.79mm2, PVC insulation, colour chart 1, page 166. Cores laid up, overall aluminium/polyester foil screen, tinned copper drain wire (20AWG), PVC sheath. Part No.
Alt. to Belden
No. of Cores
Weight kg/km
O/D mm
1804COFYL 1804COFYH
9418 LSHF
4 4
78 78
6.2 6.2
† Applies to CE marked FSC branded stock only
A full range of 22AWG cored cables is available from stock with LSHF and duct grade versions available to order. *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
FS cables
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
11
Overall Screened Multipairs DATA Overall Screened Multipair Data Cable RS232
Widely used for computers, point of sale, control systems and RS232 applications. This is a general purpose overall screened twisted paired cable. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 24AWG
Technical Information - 24AWG & 22AWG
Tinned copper conductor 24(7) AWG,
Voltage Rating:
0.22mm2, PVC insulation. Twisted into
Temperature Rating: Capacitance:
pairs, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), PVC sheath.
UL Style*: Colour Code: Part No.
Alt. to Belden
O/D mm
1 1 1 2 2 3 3 3 4 4 4 5 5 6 6
21 21 44 32 32 49 49 66 54 54 72 66 66 72 72
3.9 3.9 6.2 5.6 5.6 5.9 5.9 8.1 6.7 6.7 8.9 7.4 7.4 7.4 7.4
Part No.
Alt. to Belden
2406POFYD DUCT 2407POFY 9507 2407POFYH LSHF 2408POFYL 9508 2408POFYH LSHF 2409POFY 9509 2410POFYL 9510 2410POFYH LSHF 2415POFY 9515 2415POFYH LSHF 2419POFYL 9519 2419POFYH LSHF 2425POFYL 9525 2425POFYH LSHF 2450POFY 9550
No. of Pairs
Weight kg/km
O/D mm
6 7 7 8 8 9 10 10 15 15 19 19 25 25 50
93 80 80 97 97 104 119 119 160 160 192 192 243 243 460
9.6 7.5 7.5 8.2 8.2 8.5 9.3 9.3 10.5 10.5 11.4 11.4 12.8 12.8 18.0
Construction - 22AWG
2206POFY
FS
Tinned copper conductor 0.34mm2, PVC insulation. Twisted into pairs, overall aluminium/polyester foil screen,
FS
cables
Weight kg/km
2403POFYD
cables
2401POFYL 9501 2401POFYH LSHF 2401POFYD DUCT 2402POFYL 9502 2402POFYH LSHF 2403POFYL 9503 2403POFYH LSHF 2403POFYD DUCT 2404POFYL 9504 2404POFYH LSHF 2404POFYD DUCT 2405POFYL 9505 2405POFYH LSHF 2406POFYL 9506 2406POFYH LSHF
No. of Pairs
300V CE: 450/750V† +80°C 1 Pair: Core to core 131pF/m Core to screen 243pF/m 24AWG: Core to core 98pF/m Core to screen 164pF/m 22AWG: Core to core 114pF/m approx Core to screen 206pF/m approx 2464 Chart 3 page 166
tinned copper drain wire (24AWG), PVC sheath. Part No.
Weight kg/km
22 22 22 22 22 22 22 22 22
2 3 4 5 6 9 11 15 19
38 50 71 81 88 123 160 190 234
† Applies to CE marked FSC branded stock only
O/D mm
FS
FS
FS
FS
5.8 6.1 6.7 cables 7.4 7.9 9.1 9.9 10.9 12.8
cables
cables
No. of Pairs
cables
2202POFY 2203POFY 2204POFY 2205POFY 2206POFY 2209POFY 2211POFY 2215POFY 2219POFY
AWG
*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
Low Smoke Halogen Free
Duct Grade
Tel: 01727 840 841
Fax : 01727 840 842
FS
cables
FS cables
12
DATA Individually Screened Two Pair
Individually Screened Two Pair Data Cable 22AWG N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Used extensively in the security industry for CCTV applications including telemetry. Also suitable for computer and instrumentation applications where it is important to provide a high level of screening from external sources, together with low levels of cross talk between pairs. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - Individually Screened
Technical Information
Tinned copper conductor 22(7) AWG 0.35mm2,
Voltage Rating:
polypropylene insulation, twisted into pairs, each pair
2202PIFR
Temperature Rating: Nominal Impedance: Capacitance:
aluminium/polyester foil screened, common tinned copper drain wire (24AWG), PVC sheath. The duct grade version has a black UV stable polyethylene sheath over the standard PVC cable to provide a high
Colour Code:
300V CE: 450/750V† +60°C 45 Ohms Core to core 115pF/m Core to screen 203pF/m Red/Black & Green/White
degree of weather resistance, while the armoured version is protected by heavy galvanised steel wires and an external grade sheath. Part No.
2202PIFR 2202PIFRW 2202PIFRL 2202PIFRH 2202PIFRH06 2202PIFRD 2202PIFRA
Alt. to Belden
8723 WHITE LSF LSHF VIOLET DUCT SWA
No. of Pairs
AWG
2 2 2 2 2 2 2
22(7) 22(7) 22(7) 22(7) 22(7) 22(7) 22(7)
Weight kg/km
O/D mm
32 32 32 32 32 50 210
4.2 4.2 4.2 4.2 4.2 6.2 9.8
2202PIFRA cables
FS
Construction - Individually and Overall Screened
Technical Information
Tinned copper conductor 22(7) AWG 0.35mm2,
Voltage Rating:
polypropylene insulation, twisted into pairs, each pair Temperature Rating: Nominal Impedance: Capacitance:
individually screened with aluminium/polyester foil and 24AWG tinned copper drain wire, overall aluminium/ polyester foil and 24AWG tinned copper drain wire,
FS cables
PVC sheath.
Part No.
2202PTFRL 2202PTFRH
UL Style: Colour Code:
300V CE: 450/750V† +60°C 45 Ohms Core to core 115pF/m Core to screen 203pF/m 2717 Red/Black & Green/White
Alt. to Belden
No. of Pairs
AWG
Weight kg/km
O/D mm
8728 LSHF
2 2
22(7) 22(7)
42 42
5.2 5.2
cables
FS
† Applies to CE marked FSC branded stock only
FS cables
Low Smoke Halogen Free
Duct Grade
SWA
www.fscables.com
sales@fscables.com
13
Individually Screened Multipairs DATA Individually Screened Multipair Data Cable 22AWG
These cables are used extensively within security, computer and instrumentation applications. Many sizes are also used within the audio field as snake cables where the individual screening of pairs reduces cross talk. The 3 pair version is particularly popular within the security industry for CCTV and access control systems. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 22AWG
Technical Information
Tinned copper conductor 22(7) AWG, 0.35mm2.
Voltage Rating:
Polypropylene insulated. Twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (24AWG), PVC sheath.
Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:
Part No.
Alt. to Belden
No. of Pairs
AWG
300V CE: 450/750V† +80°C 50 Ohms Core to core 98pF/m Core to screen 180pF/m 2919 Chart 3 page 166
Weight kg/km
2203PIFRD
O/D mm
3
22(7)
70
7.0
LSHF
3
22(7)
70
7.0
2203PIFRA
SWA
3
22(7)
330
11.1
2203PIFRD
DUCT
3
22(7)
96
8.6
2206PIFRL
8778
6
22(7)
123
9.2
2206PIFRH
LSHF
6
22(7)
123
9.2
2209PIFR
8774
9
22(7)
177
10.6
2209PIFRH
LSHF
9
22(7)
177
10.6
2211PIFR
8775
11
22(7)
201
11.8
2212PIFR
9768
12
22(7)
226
12.1
2212PIFRH
LSHF
12
22(7)
226
12.1
2215PIFR
8776
15
22(7)
290
13.9
2217PIFR
9769
17
22(7)
331
14.7
2219PIFR
8769
19
22(7)
348
15.3
2227PIFR
8773
27
22(7)
502
18.0
2237PIFR
9767
37
22(7)
739
20.3
2206PIFRL
FS
FS
FS
cables
FS
FS
FS
FS
FS
*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
Low Smoke Halogen Free
Duct Grade
Tel: 01727 840 841
SWA
Fax : 01727 840 842
cables
cables
cables
cables
† Applies to CE marked FSC branded stock only
cables
8777
2203PIFRH
cables
2203PIFRL
cables
14
DATA Individually Screened Multipairs
Individually Screened Multipair Data Cable 24AWG Low Capacitance RS422 For RS422 connection and any other application requiring both low capacitance and excellent isolation between pairs. Used for CAD/CAM and many other industrial applications with high data rates. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
Technical Information
Construction - 24AWG
Voltage Rating:
Tinned copper conductor 24(7) AWG 0.22mm , 2
foam polyolefin insulation. Twisted into pairs, each
2402PIFFD
The insulation and sheath materials are replaced
pair aluminium/polyester foil screened, tinned copper drain wire (24AWG), PVC sheath.
Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:
2406PIFF
cables
FS
FS
Part No.
Alt. to Belden
No. of Pairs
300V CE: 450/750V† +60°C 100 Ohms Core to core 41 pF/m Core to screen 76 pF/m 2463 Chart 3 page 166
Weight kg/km
O/D mm
2402PIFFL
9729
2
66
6.7
2402PIFFH
LSHF
2
66
6.7
2402PIFFD
DUCT
2
79
10.2
2402PIFFA
SWA
2
178
12.6
2403PIFFL
9730
3
80
8.5
2403PIFFH
LSHF
3
80
8.5
2404PIFF
9728
4
97
9.2
2404PIFFH
LSHF
4
97
9.2
2406PIFF
9731
6
137
10.7
2406PIFFH
LSHF
6
137
10.7
2409PIFF
9732
9
203
12.4
2411PIFF
9733
11
226
14.6
2412PIFF
9734
12
242
14.6
2415PIFF
9735
15
300
16.3
2417PIFF
9736
17
326
17.1
2419PIFF
9737
19
348
17.1
2427PIFF
9738
27
557
20.3
cables
† Applies to CE marked FSC branded stock only cables
FS
Some of the above cables are also available in armoured, duct grade or Low Smoke Halogen Free versions even where not listed. Please call for details. * UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
FS cables
Low Smoke Halogen Free
Duct Grade
SWA
www.fscables.com
sales@fscables.com
15
Overall Foil & Braid Screened Pairs DATA
Overall Foil & Braid Screened Paired Data Cable RS485 Capacitance N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire24AWG Resistant (IECLow 60331) LSHF Power Cable – 0.6/1kV Designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 24AWG
Technical Information
Tinned copper conductor 24(7) AWG 0.22mm2,
Voltage Rating:
polyethylene insulation. Twisted into pairs, overall aluminium/polyester foil screened, tinned copper drain wire (24AWG), overall tinned copper braid (90%). PVC sheath.
Part No.
Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:
Alt. to Belden
No. of Pairs
300V CE: 450/750V† +80°C 120 Ohms Core to core 42 pF/m Core to screen 76 pF/m 2919 Chart 5 page 166
Weight kg/km
O/D mm
2401POHPL>
9841
1
64
5.8
2401POHPD
DUCT
1
92
8.4
2401POHPH
LSHF
1
64
5.8
2401POHPA
SWA
1
192
9.6
2402POHPL+
9842
2
95
8.6
2402POHPD
DUCT
2
118
11.1
2402POHPH
LSHF
2
95
8.6
2402POHPA
SWA
2
251
12.5
3
108
9.2
LSHF
3
108
9.2
2404POHP
9844
4
125
9.9
2404POHPH
LSHF
4
125
9.9
2402POHPD
FS
FS
FS
FS
cables
cables
9843
cables
2403POHP 2403POHPH
2401POHPH
cables
† Applies to CE marked FSC branded stock only
> Single pair 2401POHPL is supplied with blue & white cores (Western Electric colour code, page 166) as standard or black & white cores as special order. Please specify if you have a preference at time of order.
FS
FS
FS
cables
FS
2402POHP is an alternative to Allen Bradley type 1747CD * UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or
cables
+
approved by UL. If you require UL approved versions please tell us when you first enquire. Low Smoke Halogen Free
Duct Grade
SWA
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
16
DATA Overall Foil & Braid Screened Cores
Overall Foil & Braid Screened Cored Data Cable RS232 & RS423 A range of high performance cables for use over extended distances at high data rates for RS232 and RS423 applications. Also well suited to industrial measurement where low signal distortion is required. These cables are widely used in CAD/CAM applications.
Technical Information
Construction - 24AWG Tinned copper conductor 24(7) AWG, 0.22mm , foam 2
polyolefin insulation. Cores laid up, overall
2405CODF
aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath.
Part No.
cables
FS
Voltage Rating: Temperature Rating: Capacitance:
Alt. to Belden
No. of Cores
UL Style*: Colour Code:
Weight kg/km
300V +80째C Core to core 40 pF/m Core to screen 72 pF/m 2919 Up to 10 core Chart 1 page 166 Above 10 core Chart 2 page 166
O/D mm
2402CODF
N/A
2
33
4.7
2403CODF
9925
3
38
5.5 5.8
2404CODF
9927
4
45
2405CODF
9929
5
51
6.3
2406CODF
9931
6
58
6.7
2407CODF
9932
7
62
6.8
2408CODF
9933
8
68
7.1 7.6
2409CODF
9934
9
77
2410CODF
9935
10
83
7.8
2415CODF
9936
15
107
8.9
2425CODF
9937
25
165
11.3
2437CODF
9938
37
207
12.7
FS cables
cables
FS
*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
FS cables
www.fscables.com
sales@fscables.com
17
Overall Foil & Braid Screened Pairs DATA Overall Foil & Braid Screened Paired Data Cable RS232 & RS422
A range of high performance cables for use over extended distances at high data rates for RS232 and RS422 applications. Also well suited to industrial measurement applications where low signal distortion is required. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 24AWG
Technical Information
Tinned copper conductor 24(7) AWG, 0.22mm2,
Voltage Rating:
foam polyolefin insulation. Twisted into pairs, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath.
Part No.
Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:
300V CE: 450/750V† +80°C 100 Ohms Core to core 41 pF/m Core to screen 72 pF/m 2919 Chart 5 page 166
Weight kg/km
2402PODF
8102
2
61
6.8
2402PODFH
LSHF
2
61
6.8
2403PODFL
8103
3
71
7.1
2404PODF
8104
4
80
7.6
2405PODF
8105
5
89
7.9
2406PODF
8106
6
104
8.6
2406PODFH
LSHF
6
104
8.6
2407PODF
8107
7
106
8.6
2408PODF
8108
8
118
9.3
2408PODFH
LSHF
8
118
9.3
2410PODF
8110
10
150
10.9
2412PODF
8112
12.5+
165
11.8
2415PODF
8115
15
196
12.6
2418PODF
8118
18
235
13.6
2419PODF
N/A
19
248
13.6
2425PODF
8125
25
297
16.1
FS
FS
cables
FS
FS
FS
FS
FS
Twelve pairs plus one conductor. *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire. Low Smoke Halogen Free
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
+
FS
cables
† Applies to CE marked FSC branded stock only
O/D mm
cables
No. of Pairs
cables
Alt. to Belden
2406PODF
cables
18
DATA Individual & Overall Screened Multipairs
Individual & Overall Screened Multipair Data Cable 24AWG RS422 Low Capacitance Designed for RS422 data connections, this cable combines low capacitance insulation with very high levels of screening to provide high speed, interference free, data transmission. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Technical Information
Construction - 24AWG Tinned copper conductor 24(7) AWG 0.22mm , foam 2
polyolefin insulation. Twisted into pairs, each pair
2402PTMFH
individually aluminium/polyester foil screened with an overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid
cables
FS
Alt. to Belden
2402PTMFL
8162
2402PTMFH
LSHF
Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:
(65%). PVC sheath. Part No.
Voltage Rating:
No. of Pairs
300V CE: 450/750V† +60°C 100 Ohms Core to core 41 pF/m Core to screen 72 pF/m 2493 Chart 3 page 166
Weight kg/km
O/D mm
2
92
8.7
2
92
8.7
2403PTMFL
8163
3
104
9.1
2403PTMFH
LSHF
3
104
9.1
2404PTMF
8164
4
121
9.8
2404PTMFH
LSHF
4
121
9.8
2406PTMF
8166
6
150
11.3
2407PTMF
8167
7
158
11.3
2407PTMFH
LSHF
7
158
11.3
2408PTMF
8168
8
177
12.0
2410PTMF
8170
10
245
15.0
2415PTMF
8175
15
325
17.0
2418PTMF
8178
18
354
17.5
2425PTMF
8185
25
522
21.0
FS cables
cables
FS
FS cables
† Applies to CE marked FSC branded stock only *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
19
Individually Screened Multipairs DATA Individually Screened Multipair Data Cable 20AWG & 18AWG N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Widely used in monitoring, computer, instrumentation and audio applications where the individually screened pairs reduce cross talk. Reduced losses are achieved through the use of 20AWG or 18AWG conductors making this cable ideal for long runs. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - 20AWG
Technical Information
2 Pair - Tinned copper conductor 20(7)AWG, 0.56mm2, PVC insulated, twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (22AWG). PVC sheath.
Voltage Rating:
Multipair - Tinned copper conductor 20(7)AWG, 0.56mm2, polypropylene insulated. Twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (22AWG), PVC sheath.
Part No.
Alt. to Belden
No. of Pairs
Weight kg/km
Temperature Rating: Nominal Impedance: UL Style*: Colour Code:
O/D mm
300V CE: 450/750V† +60°C 45 Ohms+ 2pair: 2464 Above 2pair: 2919 2pair: Red/Black & Green/White Above 2pair: Chart 3 page 166
2009PIFP
Capacitance in pF/m C/S
C/C
2002PIFYL 2002PIFYH 2003PIFPL 2003PIFPH 2006PIFP 2009PIFP 2011PIFP 2012PIFP 2015PIFP
9402 LSHF 9873 LSHF 9874 9875 9876 9877 9879
2 2 3 3 6 9 11 12 15
76 76 104 104 182 270 302 322 384
7.6 7.6 8.4 8.4 10.9 13.6 15.2 15.2 17.0
180 180 98 98 98 98 98 98 98
Construction - 18AWG
Technical Information
2 Pair - Tinned copper conductor 18(19)AWG, 0.96mm2, PVC insulated, twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (20AWG). PVC sheath.
Voltage Rating:
Part No.
Alt. to Belden
No. of Pairs
Weight kg/km
Colour Code:
O/D mm
Capacitance in pF/m C/S
C/C
1802PIFYL 1802PIFYH 1803PIFP 1803PIFPH 1806PIFP 1806PIFPH
9368 LSHF 9773 LSHF 9774 LSHF
2 2 3 3 6 6
103 103 139 139 259 259
9.6 9.6 10.3 10.3 14.3 14.3
187 187 98 98 98 98
FS
FS
FS
FS
FS
FS
FS
FS
335 335cables 180 180 180 180
+
cables
cables
*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.
cables
† Applies to CE marked FSC branded stock only
1802PIFYL
cables
Multipair - Tinned copper conductor 18(19)AWG, 0.96mm2, polypropylene insulated. Twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (20AWG), PVC sheath.
300V CE: 450/750V† +60°C 45 Ohms+ 2pair: 2464 Above 2pair: 2919 2pair: Black/Red Above 2pair: Chart 3 page 166
cables
Temperature Rating: Nominal Impedance: UL Style:
312 312 180 180 180 180 180 180 180
Impedence figure not applicable on two pair version
Low Smoke Halogen Free
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
20
DATA Overall Foil & Braid Screened Pairs & Cores
Overall Foil & Braid Screened Data Cables RS232 & RS422 A range of high performance cables for use over extended distances at high data rates for RS232 applications. They are also well suited to industrial measurement where low signal distortion is required. The 24AWG foil & braid twisted paired cable runs over RS232 & RS422 protocols. Excellent dual screening enables this cable to carry signals over long distances with minimum distortion. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke. Construction - 24AWG
2402PODP
Tinned copper conductor 24(7) AWG, 0.22mm2, polyethylene insulation. Twisted into pairs, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath. Part No.
2402PODP 2402PODPH 2403PODP 2404PODP 2405PODP 2406PODP 2407PODP 2409PODP 2410PODP 2412PODP 2418PODP 2425PODP
Weight kg/km
O/D mm
9829 LSHF 9830 9831 9832 9839 9833 9834 9835 9836 9837 9838
2 2 3 4 5 6 7 9 10 12 18 25
61 61 70 79 84 97 103 130 140 155 225 295
7.4 7.4 7.7 8.4 8.6 9.3 9.4 10.6 11.5 11.8 14.4 17.1
Tinned copper conductor 22(7) AWG, 0.35mm2, semi rigid PVC insulation. Cores laid up, overall. Aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath
Part No.
FS cables
cables
FS
FS cables
2203CODY 2204CODY 2205CODY 2206CODY 2207CODY 2208CODY 2209CODY 2210CODY 2215CODY 2225CODY 2237CODY 2250CODY
UL Style*: Colour Code:
300V +80째C 100 Ohms Core to core 51 pF/m Core to screen 90 pF/m 2919 Chart 5 page 166
No. of Pairs
cables
FS
Technical Information Voltage Rating: Temperature Rating: Nominal Impedance: Capacitance:
Alt. to Belden
Construction - 22AWG
2209CODY
The insulation and sheath materials are replaced
Technical Information Voltage Rating: Temperature Rating: Nominal Impedance: Capacitance: Up to 5core -
300V +80째C 100 Ohms Core to core 121 pF/m, Core to screen 220 pF/m Above 5core -Core to core 115 pF/m Core to screen 207 pF/m UL Style*: 2464 Colour Code: Up to 10 core: Chart 1 page 166 Above 10 core: Chart 2 page 166
Alt. to Belden
No. of Cores
Weight kg/km
9939 9940 9941 9942 9943 9944 9945 9946 9947 9948 9949 9950
3 4 5 6 7 8 9 10 15 25 37 50
41 48 55 63 65 74 85 94 130 189 238 348
O/D mm
5.1 5.5 5.8 6.2 6.3 6.6 7.1 7.6 8.6 10.4 11.7 14.1
*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire. Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
21
Instrumentation, Process Control & PLTC DATA Instrumentation, Process control & PLTC
Industrial process control and instrumentation cables suitable for use in a wide variety of industries from nuclear energy generation to security and access control. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - Individually and Overall Screened Pairs Plain copper conductor 18(7) AWG 0.88mm2, Low Smoke Halogen Free insulation with a nylon skin. Conductors twisted into pairs, black and white numbered pairs, each pair individually aluminium/polyester foil
1802PTFNH
screened with a 20(7) AWG tinned copper drain wire, pairs laid up with isolated screens. Overall screen is aluminium/polyester foil screen with 20(7) AWG tinned copper drain wire. Low Smoke Halogen Free sheath. Part No.
1802PTFNH
Alt. to Belden
No. of Pairs
Weight kg/km
O/D mm
Voltage
1048A LSHF
2
115
9.9
600V
Construction - Overall Screened Triple 14AWG 3 x 14(41) AWG, 2.0mm2, plain copper conductor, (colour code: black, white, red) Low Smoke Halogen Free insulation, polyester tape, 90% tinned copper wire braid, black Low Smoke Halogen Free sheath. Part No.
No. of Cores
Weight kg/km
3
128
1403COBYH
O/D mm
Voltage
9.1
600V
Construction - Overall Screened Triple 22 & 18AWG Tinned copper conductor, colour coded PVC insulation, black, red, white. Aluminium/polyester foil screen with drain wire. PVC jacket.
FS
cables
FS
FS
FS
FS
FS
No. of Cores
AWG
CSA mm2
Weight kg/km
O/D mm
Voltage
2203COFY 1803COFY
9363 9365
3 3
22(7) 18(16)
0.35 0.79
39 64
5.3 6.3
300V 300V
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Low Smoke Halogen Free
cables
FS
Alt. to Belden
cables
FS
Part No.
cables
22
DATA IBM, Ethernet & Twin-Ax Cables
IBM Cables, Ethernet Cables & Twin-Ax Cables Although many of these cables are no longer used on new installations we still have stock of some types which can be useful if you are extending an existing system. Please call us to discuss your needs. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke. Part No.
2202PTDP
Reference
The insulation and sheath materials are replaced
Alt. to Belden
IBM Part No.
Description
O/D mm
IBM Cables 2202PTDP
IBM Type 1A
9688
4716748
2 x 2 x 22AWG
7.8 x 12
2202PTDPH
IBM Type 1A
LSHF
4716734
2 x 2 x 22AWG
7.8 x 12
2404PUY
IBM Type 3
-
-
4 x 2 x 22AWG
4.7
2602PODF
IBM Type 6
1215A
4716743
2 x 2 x 26(7)AWG
8.7
2601PODF
IBM Type 7
-
4716746
1 x 2 x 26(7)AWG
6.3
Description
Stranding AWG
Capacitance pF/m C/C
O/D mm
Trunk
12(1)
Part No.
Alt. to Belden
Ethernet 10BASE5 1201AXDD
9880
85
10.3
2004PTMFH
9901 LSHF
Grey AUI Drop 4 x 2 x 20(7)
55
10.7
2203PTMP
9891
Blue AUI Drop 3 x 2 x 22(7)
55
9.9
Stranding AWG
Capacitance pF/m C/C
O/D mm
+ 1 x 2 x 20(7) Part No.
Alt. to Belden
Description
Ethernet 10BASE2 200278DPH
cables
FS
2001AXD
9907
Thinnet
20(19)
86
4.6
2001AXDH
LSHF
Thinnet
20(19)
86
4.6
Twin-Axial cables were originally developed for I/O switching & process control applications. Now widely used in commercial applications such as building management systems. Most types are also stocked in Low Smoke Halogen Free versions as well as PVC. If the Twin-Ax you are looking for is not shown please call us. Part No.
FS cables
cables
FS
FS cables
Alt. to Belden
AWG
O/D mm
Cap. pF/m C/C
Imp. Ohms
Colour
Twin-Ax 220215FF
9182
22(19)
8.9
29
150
Black
220215FFH
LSHF
22(19)
8.9
29
150
Black
200278BP
9272
20(7)
6.2
65
78
Blue
200278BPH
LSHF
20(7)
6.2
65
78
Blue
200278DP
9463
20(7)
6.2
65
78
Blue
200278DPH
LSHF
20(7)
6.2
65
78
Blue
200210DP
9207
20(7)
8.4
51
100
Black
200210DPH
LSHF
20(7)
8.4
51
100
Black
160212DP
9860
16(1)
11.2
36
124
Black
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
23
Transducer & Load Cell Cables DATA Transducer & Load Cell Cables
Developed for accurate signal transmission in physically demanding conditions the FSC range of transducer and load cell cables cover all the popular types. The ultra tough polyurethane jacket provides excellent protection against both water and mechanical damage. To guard against the effects of nearby power cables or other sources of electromagnetic radiation a choice of either a foil screen with drain wire or a high density tinned copper wire braid is offered.
Construction - Foil Screened
Technical Information
Tinned or plain copper conductor, colour coded PE or
Voltage Rating:
300V
PVC insulation, polyester tape, tinned copper drain
Temperature Rating:
-30ยบC to +80ยบC
wire, inward facing aluminium/polyester tape, tough
Max Conductor Resistance:
polyurethane gloss jacket.
0.09mm2 (28AWG):
232 Ohms per km
0.22mm2 (24AWG):
92 Ohms per km
0.34mm2 (22AWG):
57 Ohms per km
Part No.
Cores x mm2
Weight kg/km
O/D mm
Insulation Type
Screen Type
Colour
9950020408
4 x 0.22
29
4.6
PE
Foil
Orange
9950020608
6 x 0.22
36
6.2
PE
Foil
Orange
9950030408
4 x 0.34
35
6.0
PE
Foil
Orange
9950009405
4 x 0.09
21
4.0
PVC
Foil
Grey
Construction - Braid Screened
Technical Information
Tinned or plain copper conductor, colour coded cold
Voltage Rating:
300V
resistant PVC insulation, polyester tape, high
Temperature Rating:
-30ยบC to +80ยบC
coverage tinned copper wire braid, tough
Max Conductor Resistance:
polyurethane gloss jacket.
0.055mm2 (30AWG):
367 Ohms per km
0.5mm2 (20AWG):
39 Ohms per km
9950020408
9960050400 Weight kg/km
O/D mm
Insulation Type
Screen Type
Colour
12 x 0.055
32
4.3
PVC
Braid
Black
9960020400
4 x 0.22
34
4.7
PVC
Braid
Black
9960050400
4 x 0.50
65
6.8
PVC
Braid
Black
39300112PUR
FS
FS
cables
Cores x mm2
cables
Part No.
cables
FS
FS
FS
FS
FS
cables
cables
Other sizes, colours and insulation types can be supplied for quantities as low as 2km. Cable can be printed with your company name or message and phone number. See pages 152-153 for details.
cables
FS
Full specifications sheets are available on the above giving electrical characteristics and colour codes.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
24
DATA Structured Wiring
Cat5E UTP, Cat5E Screened, Cat 6A Screened & Unscreened & Cat 7 Screened The benefits of running voice, data or video over the same cabling system are considerable. The versatility of the latest structured wiring systems ensure confidence that future needs can be easily met with minimal expense or inconvenience to other network users. The majority of installations use unshielded twisted pair (UTP) cables. Baluns allow RGB video signals to be transmitted using UTP, saving the cost of running dedicated wiring for many dealing room systems. Where higher performance cables for ATM, multimedia and similar applications are required, please call us for the latest information. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
Part No.
Description
Colour Weight kg/km
Cat-5E UTP Solid Conductors C51HR† 1 x 2 x 24AWG UTP LSHF C5E2HR* 2 x 2 x 24AWG UTP LSHF C5EB 4 x 2 x 24AWG UTP PVC C5EC 4 x 2 x 24AWG UTP PE C5ECB 4 x 2 x 24AWG UTP PE C5ER 4 x 2 x 24AWG UTP PVC C5EHB 4 x 2 x 24AWG UTP LSHF C5EHR 4 x 2 x 24AWG UTP LSHF C5ER-Shotgun 4 x 2 x 24AWG UTP PVC C5EHR-Shotgun 4 x 2 x 24AWG UTP LSHF Cat-5E UTP Conductors (Patch) Stranded C5EPB00 4 x 2 x 24AWG UTP PVC C5EPB01 4 x 2 x 24AWG UTP PVC C5EPB03 4 x 2 x 24AWG UTP PVC C5EPB04 4 x 2 x 24AWG UTP PVC C5EPB05 4 x 2 x 24AWG UTP PVC C5EPB06 4 x 2 x 24AWG UTP PVC C5EPB07 4 x 2 x 24AWG UTP PVC C5EPB08 4 x 2 x 24AWG UTP PVC C5EPB09 4 x 2 x 24AWG UTP PVC C5EPB10 4 x 2 x 24AWG UTP PVC C5EPHR00 4 x 2 x 24AWG UTP LSHF C5EPHR01 4 x 2 x 24AWG UTP LSHF C5EPHR03 4 x 2 x 24AWG UTP LSHF C5EPHR04 4 x 2 x 24AWG UTP LSHF cables C5EPHR05 4 x 2 x 24AWG UTP LSHF C5EPHR06 4 x 2 x 24AWG UTP LSHF C5EPHR07 4 x 2 x 24AWG UTP LSHF C5EPHR08 4 x 2 x 24AWG UTP LSHF C5EPHR09 4 x 2 x 24AWG UTP LSHF C5EPHR10 4 x 2 x 24AWG UTP LSHF cables
FS
FS
cables
FS
Grey Grey Grey Black Black Grey Violet Grey Grey Orange
12 22 36 36 36 36 36 36 74 74
Black Blue Red White Grey Violet Pink Orange Yellow Green Black Blue Red White Grey Violet Pink Orange Yellow Green
36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36
O/D mm
The insulation and sheath materials are replaced
Pack Lengths
2.8 Reel 4.4 Reel 5.5 305m Box 5.5 Reel 5.5 305m Box 5.5 Reel 5.5 305m Box 5.5 Reel 10.8 x 6.2 Reel 10.8 x 6.2 Reel 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box Reel Reel Reel Reel Reel Reel Reel Reel Reel Reel
RJ45 Part No.
RJ45 Strain Relief Boot
RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP
RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST
RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP
RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST
† Not to Cat-5E standard * This cable is an alternative to Belden 1588A
FS cables
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
25
Structured Wiring DATA Part No.
Description
Colour
Weight kg/km
O/D mm
Pack Lengths
RJ45 Part No.
RJ45 Strain Relief Boot
Cat 5E FTP Overall Foil Screened Solid Conductors C5EFR
4 x 2 x 24AWG FTP PVC
Grey
40
6.0
Reel
RJ45STPP
RJ45UTPP-ST
C5EFHR
4 x 2 x 24AWG FTP LSHF
Orange
40
6.0
Reel
RJ45STPP
RJ45UTPP-ST
Cat 5E FTP Overall Foil Screened Stranded Conductors (Patch) C5EPFB01
4 x 2 x 24AWG FTP PVC
Blue
40
6.0
305m Box
RJ45STPP
RJ45UTPP-ST
C5EPFB03
4 x 2 x 24AWG FTP PVC
Red
40
6.0
305m Box
RJ45STPP
RJ45UTPP-ST
C5EPFB05
4 x 2 x 24AWG FTP PVC
Grey
40
6.0
305m Box
RJ45STPP
RJ45UTPP-ST
C5EPFB10
4 x 2 x 24AWG FTP PVC
Green
40
6.0
305m Box
RJ45STPP
RJ45UTPP-ST
Cat 6 UTP Solid Conductors C6B
4 x 2 x 24AWG UTP PVC
Grey
43
6.3
305m Box
-
-
C6R
4 x 2 x 24AWG UTP PVC
Grey
43
6.3
Reel
-
-
C6HB
4 x 2 x 24AWG UTP LSHF
Violet
43
6.3
305m Box
-
-
C6HR
4 x 2 x 24AWG UTP LSHF
Grey
43
6.3
Reel
-
-
Cat 6 FTP Solid Conductors C6FR
4 x 2 x 23AWG FTP PVC
Grey
58
7.2
Reel
-
-
C6FHR
4 x 2 x 23AWG FTP LSHF
Orange
58
7.2
Reel
-
-
8.0
Reel
-
-
Reel
-
-
Reel
-
-
Cat 6A F-FTP Individual & Overall Foil Screened Solid Conductors C6GFFH
4 x 2 x 23AWG F-FTP LSHF
Blue
58
Cat 7 S/FTP Individual Foil & Overall Braid Screened Solid Conductors C7HR08
4 x 2 x 23AWG S/FTP LSHF
C7HR08-Shotgun 2 x (2 x 4) x 23AWG S/FTP LSHF
Orange
60
Orange
121 7.7 x 15.7
7.4
C6HB
FS
cables
FS
FS
FS
FS
FS
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Low Smoke Halogen Free
cables
FS
cables
FS
cables
26
DATA External Grade Structured Wiring
External Grade Structured Wiring Category or structured wiring cable has always been on the delicate side, but treated carefully it does the job well. Now there is a cable available to cover the more demanding jobs. Designed for fixed installations, the FSC range of duct grade or armoured Cat-5 & Cat-6 cables have heavy jackets of polyethylene to protect against moisture and give the cables extra strength. The external version is ideal for running through ducts, up the side of a building or up masts. The armoured version is great for direct burial or vandal-plagued installations. These cables are supplied on drums.
Part No.
Description
Weight kg/km
O/D mm
Cat-5E UTP C5EA
C5EC
4 x 2 x 24AWG Cat-5E UTP PE - Weatherproof
40
5.6
C5ED
4 x 2 x 24AWG Cat-5E UTP PVC/PE - Duct Grade
67
8.6
C5EA
4 x 2 x 24AWG Cat-5E UTP PVC/PE/SWA/PE - Armoured
239
12.6
C525D
25 x 2 x 24AWG Cat-5 UTP PVC/PE - Duct Grade
278
17.0
C525A
25 x 2 x 24AWG Cat-5 UTP PVC/PE/SWA/PE - Armoured
598
21.6
Part No.
Description
Weight kg/km
O/D mm
Cat-5E FTP C5EFD
4 x 2 x 24AWG Cat-5E FTP PVC/PE - Duct Grade
68
8.8
C5EFA
4 x 2 x 24AWG Cat-5E FTP PVC/PE/SWA/PE - Armoured
275
12.2
Part No.
Description
Weight kg/km
O/D mm
Cat-6 UTP cables
FS
C6D
C6D
4 x 2 x 23AWG Cat-6 UTP PVC/PE - Duct Grade
86
9.9
C6A
4 x 2 x 23AWG Cat-6 UTP PVC/PE/SWA/PE - Armoured
309
14.2
Weight kg/km
O/D mm
Part No.
FS cables
cables
FS
FS cables
Description
Cat-6 FTP C6FD
4 x 2 x 23AWG Cat-6 FTP PVC/PE - Duct Grade
105
10.2
C6FA
4 x 2 x 23AWG Cat-6 FTP PVC/PE/SWA/PE - Armoured
315
14.5
Please note the armouring and oversheathing process can sometimes affect the performance of the cable. If your installation is likely to require optimum performance please check before installing to ensure it meets your requirement. Duct Grade
SWA
www.fscables.com
sales@fscables.com
27
Cat 3 & Cat 5 Multipair ADSL DATA Cat 3 Multipair & Cat 5 Multipair
With the spread of internet access over broadband, the need for high specification cables has grown. Cable to support ADSL data rates are increasingly being installed in offices, airports, education and commercial centres. Cat-3 multipair is available in 25, 50, 100, 150 & 200 pair configurations and offers substantial benefits in terms of cost, space & weight with significantly reduced installation times when compared with multiple runs of standard 4 pair Cat-5 cable. Multipair Cat-5 offers the same advantages as Cat-3 but at higher data rates. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.
The insulation and sheath materials are replaced
Construction - Cat-3 Multipair
Technical Information
24(1) AWG solid plain copper conductor, colour coded HDPE insulation, twisted into pairs and laid up, polyester tape, PVC sheath.
Minimum Bend Radius: Conductor DCR: Colour Code:
Part No.
Cable Size
Jacket
Weight kg/km
10 x cable O/D ≤ 9,38 Ohm/100m Chart 5 page 166 O/D mm
C310
10 x 2 x 24AWG
PVC
67
7.3
C310H
10 x 2 x 24AWG
LSHF
67
7.3
C325
25 x 2 x 24AWG
PVC
186
11.5
C325H
25 x 2 x 24AWG
LSHF
186
11.5
C350
50 x 2 x 24AWG
PVC
422
17.5
C350H
50 x 2 x 24AWG
LSHF
422
17.5
PVC
710
23.5
100 x 2 x 24AWG
LSHF
710
23.5
C3150
150 x 2 x 24AWG
PVC
880
28.0
C3150H
150 x 2 x 24AWG
LSHF
880
28.0
C3200
200 x 2 x 24AWG
PVC
1047
33.0
C3200H
200 x 2 x 24AWG
LSHF
1047
33.0
Technical Information
24(1) AWG solid plain copper conductor, colour coded PE insulation twisted into pairs. Laid up into a bundle and jacketed in PVC.
Minimum Bend Radius: Conductor DCR: Colour Code:
Part No.
Cable Size
Jacket
Weight kg/km
25 x 2 x 24AWG
PVC
189
13.2
25 x 2 x 24AWG
LSHF
189
13.2
FS
FS
FS
FS
FS
cables
PVC
435
20.8
LSHF
435
20.8
cables
cables
50 x 2 x 24AWG 50 x 2 x 24AWG
cables
C550 C550H
Fax : 01727 840 842
cables
O/D mm
C525
Tel: 01727 840 841
FS
C525H
FS
10 x cable O/D ≤ 9,38 Ohm/100m Chart 5 page 166
C525H
Low Smoke Halogen Free
FS
cables
100 x 2 x 24AWG
C3100H
cables
C3100
Construction - Cat-5 Multipair
C350H
cables
28
COAXIAL RG Coaxial
RG Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV The RG cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be supplied on request as can armoured versions or alternative sheath colours. Twin and multicore versions are available in some types.
Part No.
Description
Imp. Central Ohms Cond.
Shield
Dielectric Outer Weight Sheath kg/km
O/D mm
75 Ohm
390059
cables
FS
FS cables
390006-C
RG6 Type
75
1/1.02
Ali Foil & Braid
FPE
PVC
47
6.8
390006-CH
RG6 Type LSHF
75
1/1.02
Ali Foil & Braid
FPE
LSHF
47
6.8
390006Q
RG6 Quad
75
1/1.02
2 x Ali Foil & Braid
FPE
PVC
49
7.6
390011
RG11 A/U
75
7/0.40
PCWB
PE
PVC
149
10.3
390011H
RG11 A/U LSHF
75
7/0.40
PCWB
PE
LSHF
149
10.3
390011A
RG11 A/U SWA
75
7/0.40
PCWB
PE
LDPE
380
15.7
390059
RG59 B/U
75
1/0.58
PCWB
PE
PVC
60
6.1
390059L
RG59 B/U LSF
75
1/0.58
PCWB
PE
LSF
60
6.1
390059H
RG59 B/U LSHF
75
1/0.58
PCWB
PE
LSHF
60
6.1
390059D
RG59 B/U Duct
75
1/0.58
PCWB
PE
LDPE
60
7.9
390059A
RG59 B/U SWA
75
1/0.58
PCWB
PE
LDPE
60
10.3
390059MB
RG59 Mini Black
75
1/0.41
TCWB
PE
PVC
16
3.6
390059MW
RG59 Mini White
75
1/0.41
TCWB
PE
PVC
16
3.6
390059MBH
RG59 Mini Black LSHF
75
1/0.41
TCWB
PE
LSHF
16
3.6
390059MWH
RG59 Mini White LSHF
75
1/0.41
TCWB
PE
LSHF
16
3.6
390179
RG179 B/U
75
7/0.10
SPCWB
PTFE
FEP
15
2.5
390179Y
RG179 PVC
75
1/0.35
TCWB
PE
PVC
12
2.6
390179H
RG179 LSHF
75
1/0.35
TCWB
PE
LSHF
12
2.6
390179Y-S
RG179 Stranded PVC
75
7/0.10
TCWB
PE
PVC
12
2.6
390179H-S
RG179 Stranded LSHF
75
7/0.10
TCWB
PE
LSHF
12
2.6
390216
RG216
75
7/0.40
2 x PCWB
PE
PVC
169
10.8
390216H
RG216 LSHF
75
7/0.40
2 x PCWB
PE
LSHF
169
10.8
390302
RG302
75
1/0.63
SPCWB
PTFE
FEP
4.7
5.3
Part No.
Description
Imp. Central Ohms Cond.
Shield
Dielectric Outer Weight Sheath kg/km
78, 93 & 95 Ohm 390062
RG62 A/U
93
1/0.69
PCWB
PESS
PVC
60
390062H
RG62 A/U LSHF
93
1/0.69
PCWB
PESS
PVC
60
6.2
390062A
RG62 A/U SWA
93
1/0.69
PCWB
PESS
PVC
210
10.4
390108
RG108 Twin-Ax
78 2 x 7/0.32
TCWB
PE
PVC
48
5.9
390180
RG180
95
SPCWB
PTFE
FEP
29
3.7
1/0.30
cables
FS
FS cables
O/D mm
Low Smoke Halogen Free
Duct Grade
SWA
www.fscables.com
sales@fscables.com
6.2
29
RG Coaxial COAXIAL Sheath, Insulation and Shield Codes FEP FPE LDPE PTFE PESS TCWB
Fluorinated Ethylene Propylene Foamed Polyethylene Low Density Polyethylene PolyTetraFluoroEthylene Polyethylene Semi Solid Tinned Copper Wire Braid
Description
TFE PEAS PVC PEC GFB SPCWB BNC
Crimp Plug
Crimp Jack
TetraFluoroEthylene Polyethylene Air Spaced Polyvinyl Chloride Polyethylene Cellular Glass Fibre Braid Silver Plated Copper Wire Braid
F-Type
Twist-on Plug
Boots
Crimp Plug
N-Type
Crimp Jack
Crimp Plug
TNC
Crimp Jack
Crimp Plug
Crimp Tool
Crimp Jack
Connectors RG6 Type
YB1BC1
YB1BC2
-
-
YB1FC1 YB1BC2
-
-
-
-
YTC2
RG6 Type LSHF
YB1BC1
YB1BC2
-
-
YB1FC1 YB1BC2
-
-
-
-
YTC2
YB1BC1
YB1BC2
-
-
YB1FC1 YB1BC2
-
-
-
-
YTC2
RG11 A/U
YA2BC1
YA2BC2
-
-
YA2FC1 YA2FC2
YA2NC1
YA2NC2
-
-
YTC3
RG11 A/U LSHF
YA2BC1
YA2BC2
-
-
YA2FC1 YA2FC2
YA2NC1
YA2NC2
-
-
YTC3
RG11 A/U SWA
YA2BC1
YA2BC2
-
-
YA2FC1 YA2FC2
YA2NC1
YA2NC2
-
-
YTC3
RG59 B/U PVC
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx
YA1FC1 YA1FC2
YA1NC1
YA1NC2 YA1TC1 YA1TC2
YTC1
RG59 B/U LSF
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx
YA1FC1 YA1FC2
YA1NC1
YA1NC2 YA1TC1 YA1TC2
YTC1
RG59 B/U LSHF
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx
YA1FC1 YA1FC2
YA1NC1
YA1NC2 YA1TC1 YA1TC2
YTC1
RG59 B/U Duct
YA1BC1
YA1BC2
YA1BT1
-
YA1FC1 YA1FC2
YA1NC1
YA1NC2 YA1TC1 YA1TC2
YTC1
RG59 B/U SWA
YA1BC1
YA1BC2
YA1BT1
-
YA1FC1 YA1FC2
YA1NC1
YA1NC2 YA1TC1 YA1TC2
YTC1
RG59 Mini Black
YA8BC1
YA8BC2
-
YA8BX700
-
-
-
-
-
-
YTC1
RG59 Mini White
YA8BC1
YA8BC2
-
YA8BX704
-
-
-
-
-
-
YTC1
RG59 Mini Black LSHF
YA8BC1
YA8BC2
-
YA8BX700
-
-
-
-
-
-
YTC1
RG59 Mini White LSHF
YA8BC1
YA8BC2
-
YA8BX704
-
-
-
-
-
-
YTC1
RG179 B/U
YA7BC1
YA7BC2
-
YA7BX7xx
YA7FC1
-
-
-
-
-
YTC1
RG179 PVC
YA7BC1
YA7BC2
-
YA7BX7xx
YA7FC1
-
-
-
-
-
YTC1
RG179 LSHF
YA7BC1
YA7BC2
-
YA7BX7xx
YA7FC1
-
-
-
-
-
YTC1
RG179 Stranded PVC
YA7BC1
YA7BC2
-
YA7BX7xx
YA7FC1
-
-
-
-
-
YTC1
RG179 Stranded LSHF
YA7BC1
YA7BC2
-
YA7BX7xx
YA7FC1
-
-
-
-
-
YTC1
RG216
-
-
-
-
-
-
-
-
RG216 LSHF
-
-
-
-
-
-
-
RG302
-
-
-
-
-
-
-
Crimp Plug
Crimp Jack
Twist-on Plug
Boots
Crimp Plug
Crimp Jack
Crimp Plug
RG62 A/U
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx
YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1 cables
YA1TC2
RG62 A/U LSHF
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx
YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
RG62 A/U SWA
YA1BC1
YA1BC2
YA1BT1
-
YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
RG108 Twin-Ax
-
-
-
-
-
-
-
-
-
-
-
RG180
-
-
-
-
-
-
-
-
-
-
-
BNC
F-Type
White
Tel: 01727 840 841
-
-
Fax : 01727 840 842
FS -
-
TNC
Crimp Jack
Crimp Plug
FS
Crimp Jack
Crimp Tool
FS YTC1 cables
FS
FS
FS
FS
cables
cables
04
-
FS
cables
To show the colour required please replace xx in the part number with: Black
-
N-Type
Connectors
00
-
cables
Description
-
-
cables
RG6 Quad
cables
30
COAXIAL RG Coaxial
RG Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV The RG cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be supplied on request as can armoured versions or alternative sheath colours. Twin and multicore versions are available in some types.
Part No.
Description
Imp. Central Ohms Cond.
Shield
Dielectric Outer Weight Sheath kg/km
O/D mm
50 Ohm RG Coaxial Cables
390059
cables
FS
FS cables
390008-C
RG 8 Type
50
1/2.74
Ali Foil & TCWB
PE
PE
207
10.2
390008-CH
RG 8 Type LSHF
50
1/2.74
Ali Foil & TCWB
PE
LSHF
207
10.2
390058
RG 58 C/U
50
19/0.18
TCWB
PE
PVC
46
5.1
390058H
RG 58 C/U LSHF
50
19/0.18
TCWB
PE
LSHF
46
5.1
390058D
RG 58 C/U Duct
50
19/0.18
TCWB
PE
LDPE
46
6.5
390058W
RG 58 C/U White
50
19/0.18
TCWB
PE
PVC
46
5.1
390115
RG115 A/U
50
7/0.71
2 x SPCWB
PTFE
GFB
240
10.6
390142
RG142 B/U
50
1/0.91
2 x SPCWB
PTFE
FEP
74
4.9
390165
RG165
50
7/0.81
SPCWB
PTFE
GFB
180
10.4
390174
RG174 A/U
50
7/0.16
TCWB
PE
PVC
16
2.6
390174H
RG174 A/U LSHF
50
7/0.16
TCWB
PE
LSHF
16
2.6
390178
RG178 B/U
50
7/0.10
SPCWB
PTFE
FEP
10
1.8
390179DB
RG178 B/U Double braid
50
7/0.10
2 x SPCWB
PTFE
FEP
14
2.3
390188
RG188
50
7/0.17
SPCWB
PTFE
FEP
17
2.5
390196
RG196
50
7/0.10
SPCWB
PTFE
FEP
9
2.0
390212
RG212
50
1/1.41
2 x SPCWB
PE
PVC
123
8.4
390213
RG213 /U
50
7/0.75
PCWB
PE
PVC
166
10.3
390213H
RG213 /U LSHF
50
7/0.75
PCWB
PE
LSHF
166
10.3
390214
RG214 /U
50
7/0.75
2 x SPCWB
PE
PVC
173
10.8
390214H
RG214 /U LSHF
50
7/0.75
2 x SPCWB
PE
PVC
173
10.8
390218
RG218
50
1/4.95
PCWB
PE
PVC
658
22.0
390223
RG223 /U
50
1/0.90
2 x SPCWB
PE
PVC
49
5.4
390223H
RG223 /U LSHF
50
1/0.90
2 x SPCWB
PE
LSHF
49
5.4
390225
RG225
50
7/0.79
2 x SPCWB
PTFE
GFB
268
10.9
390303
RG303
50
1/0.99
SPCWB
PTFE
FEP
47
5.3
390304
RG304
50
1/1.49
2 x SPCWB
PTFE
FEP
131
7.1
390316
RG316
50
7/0.17
SPCWB
PTFE
FEP
15
2.5
390316DB
RG316 Double Braid
50
7/0.17
2 x SPCWB
PTFE
FEP
22
2.6
390393
RG393
50
7/0.80
2 x SPCWB
PTFE
FEP
245
10.0
390400
RG400
50
19/0.20
2 x SPCWB
PTFE
FEP
55
5.1
cables
FS
FS cables
Low Smoke Halogen Free
Duct Grade
www.fscables.com
sales@fscables.com
31
RG Coaxial COAXIAL Sheath, Insulation and Shield Codes FEP FPE LDPE PTFE PESS TCWB
Fluorinated Ethylene Propylene Foamed Polyethylene Low Density Polyethylene PolyTetraFluoroEthylene Polyethylene Semi Solid Tinned Copper Wire Braid
Description
TFE PEAS PVC PEC GFB SPCWB BNC
Crimp Plug
Crimp Jack
TetraFluoroEthylene Polyethylene Air Spaced Polyvinyl Chloride Polyethylene Cellular Glass Fibre Braid Silver Plated Copper Wire Braid
F-Type
Twist-on Plug
Boots
Crimp Plug
N-Type
Crimp Jack
Crimp Plug
TNC
Crimp Jack
Crimp Plug
Crimp Tool
Crimp Jack
Connectors RG 8 Type
YA9BC1
YA9BC2
-
-
-
-
YA9NC1 YA9NC2
-
-
390L40-T1
RG 8 Type LSHF
YA9BC1
YA9BC2
-
-
-
-
YA9NC1 YA9NC2
-
-
390L40-T1 YTC1
RG 58 C/U
YA3BC1
YA3BC2
YA3BT1
YA3BX700
-
-
YA3NC1 YA3NC1 YA3TC1
YA3TC2
RG 58 C/U LSHF
YA3BC1
YA3BC2
YA3BT1
YA3BX700
-
-
YA3NC1 YA3NC1 YA3TC1
YA3TC2
YTC1
RG 58 C/U Duct
YA3BC1
YA3BC2
YA3BT1
-
-
-
YA3NC1 YA3NC1 YA3TC1
YA3TC2
YTC1
RG 58 C/U White
YA3NC1 YA3NC1 YA3TC1
YA3BC1
YA3BC2
YA3BT1
YA3BX700
-
-
YA3TC2
YTC1
RG115 A/U
-
-
-
-
-
-
-
-
-
-
-
RG142 B/U
-
-
-
-
-
-
-
-
-
-
-
RG165
-
-
-
-
-
-
-
-
-
-
-
RG174 A/U
YA7BC1
YA7BC2
-
YA7BX7xx YA7FC1
-
-
-
-
-
YTC1
RG174 A/U LSHF
YA7BC1
YA7BC2
-
YA7BX7xx YA7FC1
-
-
-
-
-
YTC1
RG178 B/U
YC6BC1
-
-
-
-
-
-
-
-
-
-
RG178 B/U Double Braid
YC6BC1
-
-
-
-
-
-
-
-
-
-
RG188
-
-
-
-
-
-
-
-
-
-
-
RG196
-
-
-
-
-
-
-
-
-
-
-
RG212
-
-
-
-
-
-
-
-
-
-
-
RG213 /U
YA4BC1
YA4BC2
-
-
-
-
YA4NC1 YA4NC2 YA4TC1
YA4TC2
YTC3
RG213 /U LSHF
YA4BC1
YA4BC2
-
-
-
-
YA4NC1 YA4NC2 YA4TC1
YA4TC2
YTC3
RG214 /U
YA5BC1
YA5BC2
-
-
-
-
YA5NC1 YA5NC2
-
-
YTC7
RG214 /U LSHF
YA5BC1
YA5BC2
-
-
-
-
YA5NC1 YA5NC2
-
-
YTC7
RG218
-
-
-
-
-
-
RG223 /U
YA6BC1
YA6BC2
-
-
-
-
YA6NC1 YA6NC2 YA6TC1
-
-
-
YA6TC2
YTC1
RG223 /U LSHF
YA6NC1 YA6NC2 YA6TC1
YA6BC2
-
-
-
-
-
-
-
-
-
-
-
RG303
-
-
-
-
-
-
RG304
-
-
-
-
-
RG316
YC4BC1
YC4BC2
-
-
-
RG316 Double Braid
-
FS
YA6TC2
YTC1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
YC4BC1
YC4BC2
-
-
-
-
-
RG393
-
-
-
-
-
-
-
RG400
YA6BC1
YA6BC2
-
-
-
-
FS
-
FS
-
YC4TC1
YC4TC2
YTC1
-
YC4TC1
YC4TC2
YTC1
cables
YA6NC1 YA6NC2 YA6TC1
-
cables
FS
cables
YA6BC1
RG225
-
-
cables
YA6TC2
YTC1
To show the colour required please replace xx in the part number with: 04
White
Tel: 01727 840 841
FS
FS
Fax : 01727 840 842
FS
FS
cables
cables
Black
cables
00
cables
32
COAXIAL Broadcast Coaxial
Broadcast Coaxial XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV
There is an increasing demand for Broadcast standard video cables. The best known are the BBC specification PSF series for which we stock a range of alternatives.
Part No.
390PS13
Description
Broadcast Coax 390PS12 PSF1/2 Style 390PS12H PSF1/2 Style LSHF 390PS13 PSF1/3 Style 390PS1301 PSF1/3 Style 390PS1302 PSF1/3 Style 390PS1303 PSF1/3 Style 390PS1306 PSF1/3 Style 390PS1310 PSF1/3 Style 390PS13H PSF1/3 Style LSHF 390PS13H01 PSF1/3 Style LSHF 390PS16 PSF1/6 Style 390PS17 PSF1/7 Style 390PS19 PSF1/9 Style Triax
Imp. Ohms
Central Cond.
75 75 75 75 75 75 75 75 75 75 75 75 75
1/0.80 1/0.80 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 7/0.32 1/0.42 1/1.40
Description
Shield
2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x PCWB TCWB 1 x TCWB + 1 x PCWB
Dielectric Outer Sheath
PE PE PE PE PE PE PE PE PE PE PE PPC PEC
PVC LSHF PVC PVC PVC PVC PVC PVC LSHF LSHF PVC PVC PUR
BNC
Colour
Weight kg/km
O/D mm
Cream Cream Cream Blue Brown Red Violet Green Cream Blue Black Cream Red
93 93 74 74 74 74 74 74 74 74 44 14 160
7.5 7.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 5.2 2.9 11.2
Crimp Tool
Crimp Plug
Crimp Jack
YB5BC1 YB5BC1 YC9BC1 -
-
Connectors PSF1/2 Style PSF1/2 Style LSHF PSF1/3 Style PSF1/3 Style LSHF PSF1/6 Style PSF1/7 Style PSF1/9 Style Triax
YTC1 YTC1 -
390CC11 cables
FS
Part No.
FS cables
cables
FS
FS cables
Description
Imp. Central Ohms Cond.
Camera Cable Triax 390CC08 Camera Cable 8 390CC08H Camera Cable 8 LSHF 390CC08P Camera Cable 8 PUR 390CF08 Camera Cable 8 Flexible 390CC11 Camera Cable 11 390CC11H Camera Cable 11 LSHF 390CC11P Camera Cable 11 PUR 390CF11 Camera Cable 11 Flexible 390CC14 Camera Cable 14 390CC14H Camera Cable 14 LSHF 390CC14P Camera Cable 14 PUR
Shield
75 1/1.0 1 x TCWB + 1 x PCWB 75 1/1.0 1 x TCWB + 1 x PCWB 75 1/1.0 1 x TCWB + 1 x PCWB 75 7/0.35 1 x TCWB + 1 x PCWB 75 1/1.40 1 x TCWB + 1 x PCWB 75 1/1.40 1 x TCWB + 1 x PCWB 75 1/1.40 1 x TCWB + 1 x PCWB 75 19/0.30 1 x TCWB + 1 x PCWB 75 7/0.75 1 x TCWB + 1 x PCWB 75 7/0.75 1 x TCWB + 1 x PCWB 75 7/0.75 1 x TCWB + 1 x PCWB
Dielectric Outer Colour Sheath
FPE FPE FPE FPE FPE FPE FPE FPE FPE FPE FPE
PVC LSHF PUR TPE PVC LSHF PUR TPE PVC LSHF PUR
Red Red Red Red Red Red Red Red Red Red Red
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
Weight kg/km
O/D mm
106 106 106 102 160 160 160 158 268 268 268
8.5 8.5 8.5 8.5 11.2 11.2 11.2 11.2 14.0 14.0 14.0
33
Broadcast Coaxial COAXIAL Telecom BT, TZC & RA Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Res LSHF Power Cable – 0.6/1kV The BT range of coaxial cables are to British Telecom specifications and are
used for interconnecting equipment. British Telecom types BT2002 & BT2003 are used for digital telephone and data links. BT2002 is equivalent to ICL Part Number 80047293. TZC coax is to a very similar standard to the BT3002 and is available in both single and multicore options from stock. The cable is designed for Ericsson systems. RA7000 has been developed as a higher performance version of BT2003 but with a smaller overall diameter. RA8000 is a high performance alternative to BT3002 with a much smaller overall diameter. Multicore versions are also available. Part No.
Description
Imp. Ohms
Central Cond.
Shield
Dielectric
Outer Sheath
Weight kg/km
O/D mm
75 75 75 75 75 75 75 75 75
7/0.20 7/0.20 7/0.20 1/0.61 1/0.61 1/0.31 1/0.31 1/0.31 1/0.31
PCWB 2 x PCWB 2 x PCWB 2 x PCWB 2 x PCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB
PEC FPE FPE PE PE PE PE PE PE
PVC PVC LSHF PVC LSHF PVC LSHF PVC PVC
31 51 51 79 79 24 24 214 392
4.6 5.1 5.1 6.7 6.7 3.5 3.5 16.0 19.5
75 75 75
1/0.31 1/0.31 1/0.31
2 x TCWB 2 x TCWB 2 x TCWB
PE PE PE
PVC PVC PVC
24 219 394
3.5 14.5 19.1
75 75 75 75 75 75
1/0.60 1/0.60 1/0.60 1/0.31 1/0.31 1/0.31
Ali Foil & PCWB Ali Foil & PCWB Ali Foil & PCWB Ali Foil & TCWB Ali Foil & TCWB Ali Foil & TCWB
FPE FPE FPE FPE FPE FPE
LSHF LSHF LSHF LSHF LSHF LSHF
30 165 535 13 124 228
4.5 17.2 24.3 2.8 11.0 14.8
Telecom BT Coaxial 3902001 BT2001 3902002 BT2002 3902002H BT2002 LSHF 3902003 BT2003 3902003H BT2003 LSHF 3903002 BT3002 3903002H BT3002 LSHF 3903002/8 BT3002 8core 3903002/16 BT3002 16core TZC Coaxial TZC75024 TZC TZC7502408 TZC 8core TZC7502416 TZC 16core RA Coaxial 390RA7000 RA7000 390RA7000/8 RA7000 8core 390RA7000/16 RA7000 16core 390RA8000 RA8000 390RA8000/8 RA8000 8core 390RA8000/16 RA8000 16core Description
BNC Crimp Plug
Crimp Jack
YB8BC2 YB8BC2 YB7BC2 YB7BC2 YB6BC2 YB6BC2 YB6BC2 YB6BC2
YB84C1 YB84C1 YB74C1 YB74C1 YB64C1 YB64C1 YB64C1 YB64C1
YB84C2 YB84C2 YB74C2 YB74C2 YB64C2 YB64C2 YB64C2 YB64C2
-
YB6BC2 YB6BC2 YB6BC2
YB64C1 YB64C1 YB64C1
YB64C2 YB64C2 YB64C2
-
YB9BC1 YB9BC1 YB9BC1 -
YB9BC2 YB9BC2 YB9BC2 -
YB94C1 YB94C1 YB94C1 -
YB94C2 YB94C2 YB94C2 -
-
Low Smoke Halogen Free
Tel: 01727 840 841
Fax : 01727 840 842
FS
FS
cables
FS
FS
FS
FS
FS
cables
cables
cables
YB6BC1 YB6BC1 YB6BC1
FS
cables
Crimp Plug
cables
TZC Coaxial Connectors TZC TZC 8core TZC 16core RA Coaxial Connectors RA7000 RA7000 8core RA7000 16core RA8000 RA8000 8core RA8000 16core
Crimp Tool
Crimp Jack
cables
Telecom BT Coaxial Connectors BT2001 BT2002 YB8BC1 BT2002 LSHF YB8BC1 BT2003 YB7BC1 BT2003 LSHF YB7BC1 BT3002 YB6BC1 BT3002 LSHF YB6BC1 BT3002 8core YB6BC1 BT3002 16core YB6BC1
T43
3902003
cables
34
COAXIAL URM Coaxial
URM Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV The URM (Uni Radio-Metric) BS 2316 cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be supplied on request, as can armoured, duct grade or alternative sheath colours. URM 70 is widely used for security applications connecting CCTV equipment where the stranded conductor centre is less likely to break than the RG 59 type. This may be important where the camera pans and tilts. Other URM cables are available to order. Part No.
Description
Imp. Ohms
Central Cond.
Shield
Dielectric
Outer Sheath
391043
URM 43
50
391054
URM 54
50
391057
URM 57
391065
URM 65
391067
Weight kg/km
O/D mm
1/0.81
PCWB
PE
PVC
40
5.0
7/0.19
2 x PCWB
PE
PVC
118
8.3
75
1/1.15
PCWB
PE
PVC
158
10.3
75
1/1.15
PCWB
PE
PVC
158
10.3
URM 67
50
7/0.77
PCWB
PE
PVC
162
10.3
URM 67 LSHF
50
7/0.77
PCWB
PE
LSHF
162
10.3
URM 70
75
7/0.19
PCWB
PE
PVC
59
5.8
URM 70 White
75
7/0.19
PCWB
PE
PVC
59
5.8
URM Coaxial Cable
391067
391067H 391070 391070W
391070H cables
FS
391070L
URM 70 LSF
75
7/0.19
PCWB
PE
LSF
59
5.8
391070H
URM 70 LSHF
75
7/0.19
PCWB
PE
LSHF
59
5.8
391070D
URM 70 Duct
75
7/0.19
PCWB
PE
LDPE
72
8.0
391074
URM 74
50
1/4.78
PCWB
PE
PVC
710
22.0
391076
URM 76
50
7/0.32
PCWB
PE
PVC
41
5.1
391091
URM 91
50
7/0.76
2 x PCWB
PE
PVC
170
11.0
391095
URM 95
50
1/0.46
PCWB
PE
Nylon
13
2.3
391106
URM 106
75
1/0.65
SPCWB
PTFE
FEP
45
5.3
391109
URM 109
50
7/0.18
SPCWB
PTFE
FEP
14
2.4
391110
URM 110
50
7/0.11
SPCWB
PTFE
FEP
12
1.8
391111
URM 111
75
7/0.10
SPCWB
PTFE
FEP
14
2.4
391112
URM 112
50
7/0.76
2 x SPCWB
PE
PVC
176
11.0
391115
URM 115
50
1/0.90
2 x PCWB
PE
PVC
85
7.2
391202
URM 202
75
7/0.25
PCWB
PEC
PVC
85
5.1
FS cables
cables
FS
FS cables
Low Smoke Halogen Free
Duct Grade
www.fscables.com
sales@fscables.com
35
URM Coaxial COAXIAL Sheath, Insulation and Shield Codes FEP FPE LDPE PTFE PESS TCWB
Fluorinated Ethylene Propylene Foamed Polyethylene Low Density Polyethylene PolyTetraFluoroEthylene Polyethylene Semi Solid Tinned Copper Wire Braid
Description
TFE PEAS PVC PEC GFB SPCWB
BNC Crimp Plug
Crimp Jack
TetraFluoroEthylene Polyethylene Air Spaced Polyvinyl Chloride Polyethylene Cellular Glass Fibre Braid Silver Plated Copper Wire Braid
F-Type
Twist-on Plug
Boots
Crimp Plug
N-Type
Crimp Jack
Crimp Plug
TNC
Crimp Jack
Crimp Plug
Crimp Tool
Crimp Jack
Connectors URM 43
YA3BC1
YA3BC2
YA3BT1
YA3BX700
-
-
YA3TC2
YTC1
URM 54
-
-
-
-
-
-
-
-
-
-
-
URM 57
-
-
-
-
-
-
-
-
-
-
-
URM 65
-
-
-
-
-
-
-
-
-
-
-
URM 67
YA4BC1
YA4BC2
-
-
-
-
YA4NC1 YA4NC2 YA4TC1
YA4TC2
YTC3
URM 67 LSHF
YA4BC1
YA4BC2
-
-
-
-
YA4NC1 YA4NC2 YA4TC1
YA4TC2
YTC3
URM 70
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
URM 70 White
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
URM 70 LSF
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
URM 70 LSHF
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
URM 70 Duct
YA1BC1
YA1BC2
YA1BT1
-
YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
URM 74
-
-
-
-
-
-
-
-
-
-
-
URM 76
-
-
-
-
-
-
-
-
-
-
-
URM 91
-
-
-
-
-
-
-
-
-
-
-
URM 95
-
-
-
-
-
-
-
-
-
-
-
URM 106
-
-
-
-
-
-
-
-
-
-
-
URM 109
YC4BC1
YC4BC2
-
-
-
-
-
-
YC4TC1
YC4TC2
YTC1
URM 110
-
-
-
-
-
-
-
-
-
-
-
URM 111
-
-
-
-
-
-
-
-
-
URM 112
-
-
-
-
-
-
-
URM 115
-
-
-
-
-
-
-
URM 202
-
-
-
-
-
-
-
Black
04
White
-
-
-
-
-
-
-
-
-
-
cables
FS
FS
FS
FS
FS
cables
cables
cables
Fax : 01727 840 842
-
FS
cables
Tel: 01727 840 841
FS -
cables
00
FS -
cables
To show the colour required please replace xx in the part number with:
YA3NC1 YA3NC1 YA3TC1
cables
36
COAXIAL Digital Satellite & Cable TV Coaxial
Digital Satellite & Cable TV Coaxial The TV range of cable television and video cables is used primarily to carry TV, Satellite and CCTV signals. These cables are all 75 ohm and supplied in a variety of versions to suit different applications. An optional heavy duty tough sheath to improve impact and moisture resistance makes the TV-DB range ideal for pulling into ducts or for direct burial. A version with an aluminium moisture barrier is also available. Cables can be armoured and sheathed with LDPE for quantities as low as 100 metres.
Part No.
392100F Shotgun
cables
FS
FS cables
cables
FS
FS cables
Description
Satellite & Cable TV Coaxial 392100 TV 100 392100W TV 100 White 392100HR TV 100 LSHF 392100F TV 100 392100F/5 TV 100 5core 392100WF TV 100 White 392100H TV 100 LSHF 392100D TV 100 Duct 392100FTV 100 Shotgun Shotgun 392125 TV 125 392125HR TV 125 LSHF 392125DB TV 125 RBS Sheath 392125F TV 125 392125F/5 TV 125 5core 392125HR TV 125 LSHF 392125WH TV 125 White LSHF 392125DBF TV 125 Duct 392167 TV 167 392167DB TV 167 Duct 392167F TV 167 392167H TV 167 LSHF 392233 TV 223 392233DB TV 223 Duct 392233F TV 233 392233H TV 223 LSHF Description
Connectors 392100 392100W 392100HR 392100F 392100F/5 392100WF 392100H 392100D 392100FShotgun 392125 392125HR 392125DB 392125F 392125F/5 392125HR 392125WH 392125DBF
Imp. Ohms
Central Cond.
Shield
Dielectric
Outer Sheath
Weight kg/km
O/D mm
75 75 75 75 75 75 75 75
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB
Airspaced PE Airspaced PE Airspaced PE Foamed PE Foamed PE Foamed PE Foamed PE Foamed PE
PVC PVC LSHF PVC PVC PVC LSHF LDPE
49 49 49 49 630 49 49 70
6.6 6.6 6.6 6.6 22.5 6.6 6.6 6.6
75
1.00
75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.67 1.67 1.67 1.67 2.33 2.33 2.33 2.33
Copper Foil & PCWB
Foamed PE
PVC
100
6.9 x 14.4
Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB
Airspaced PE Airspaced PE Airspaced PE Foamed PE Foamed PE Foamed PE Foamed PE Foamed PE Airspaced PE Airspaced PE Foamed PE Foamed PE Airspaced PE Airspaced PE Foamed PE Foamed PE
PE LSHF PE/PP PE PE LSHF LSHF LDPE PE LDPE PE LSHF PE LDPE PE LSHF
69 69 90 69 80 69 69 90 115 130 115 115 135 147 135 135
8.0 8.0 9.5 8.0 25.5 8.0 8.0 9.5 10.1 11.3 10.1 10.1 12.7 14.4 12.7 12.7
BNC
F-Type
Crimp Tool
Crimp Plug
Crimp Jack
Right Angle Plug
Crimp Plug
Crimp Jack
YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1
YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2
YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8
YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1
YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2
YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2
YB1BC1 YB2BC1 YB2BC1 YC1BC1 YB2BC1 YB2BC1 YB2BC1 YB2BC1 YC1BC1
YB1BC2 YB2BC2 YB2BC2 YC1BC2 YB2BC2 YB2BC2 YB2BC2 YB2BC2 YC1BC2
YB1BC8 -
YB1FC1 YB2FC1 YB2FC1 YC1FC1 YB2FC1 YB2FC1 YB2FC1 YB2FC1 YC1BC1
YB1FC2 YB2FC2 YB2FC2 YC1FC2 YB2FC2 YB2FC2 YB2FC2 YB2FC2 YC1BC2
YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2
Low Smoke Halogen Free
Duct Grade
www.fscables.com
sales@fscables.com
37
Composite Coaxial COAXIAL Composite Coaxial Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
To meet the increasing demands for camera cables containing a coax with power and control cores for Pan, Tilt, Zoom (PTZ) or audio we are now stocking various types. These can either be within one circular jacket for easy glanding or in??????? a shotgun style with a web between the individual elements. Please call to discuss your requirements and ask for details or samples of the current stock range. Part No.
Description Coax
Construction
Power Cores
Signal Cores
Outer Sheath
Weight kg/km
O/D mm
3900592/2
RG59 B/U
2 x 1.5mm²
2 x 0.22mm²
Circular
PVC
185
12.0
3900592/2D
RG59 B/U
2 x 1.5mm²
2 x 0.22mm²
Circular Duct
LDPE
225
14.2
3900592/2H
RG59 B/U
2 x 1.5mm²
2 x 0.22mm²
Circular LSHF
LSHF
140
12.0
390059/2
RG59 B/U
2 x 0.75mm²
-
Shotgun
PVC
92
5.9 x 12.0
390059/3
RG59 B/U
3 x 0.5mm²
-
Shotgun
PVC
92
5.9 x 12.0 6.1 x 12.0
390059/2D
3900592/2
RG59 B/U
2 x 0.75mm²
-
Circular Duct
LDPE
110
390059-Shotgun
2 x RG59 B/U
-
-
Shotgun
PVC
102
6 x 12.4
390059H-Shotgun
2 x RG59 B/U
-
-
Shotgun
LSHF
102
6 x 12.4
URM 70
2 x 0.75mm²
-
Shotgun
PVC
98
6 x 12.0
Construction
Outer Sheath
Weight kg/km
O/D mm
391070/2 Part No.
Description Coax
Screen
390179Y3
3 x RG179
Unscreened
Circular
PVC
63
7.4
390179Y5F-S
5 x RG179
Overall Foil Screen
Circular
PVC
104
9.0
390179Y5FH-S
5 x RG179
Overall Foil Screen
Circular
LSHF
104
9.4
Description
BNC
F-Type
Crimp Plug
Crimp Jack
Twist-on Plug
3900592/2
YA1BC1
YA1BC2
YA1BT1
3900592/2D
YA1BC1
YA1BC2
YA1BT1
3900592/2H
YA1BC1
YA1BC2
390059/2
YA1BC1
390059/3 390059/2D
Boots
Crimp Plug
N-Type
TNC
Crimp Jack
Crimp Plug
Crimp Jack
Crimp Tool
Crimp Jack
Crimp Plug
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YA1BC1
YA1BC2
YA1BT2
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
YTC1
390059-Shotgun
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
390059H-Shotgun
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
391070/2
YA1BC1
YA1BC2
YA1BT1
YA1BX7xx YA1FC1
YA1FC2
YA1NC1 YA1NC2 YA1TC1
YA1TC2
390179Y3
YA7BC1
YA7BC2
-
YA7BX7xx YA7FC1
-
-
-
-
-
390179Y5F-S
YA7BC1
YA7BC2
-
YA7BX7xx YA7FC1
-
-
-
-
-
YTC1
390179Y5FH-S
YA7BC1
YA7BC2
-
YA7BX7xx YA7FC1
-
-
-
-
-
YTC1
Connectors
Low Smoke Halogen Free
White
Duct Grade
Tel: 01727 840 841
Fax : 01727 840 842
FS YTC1 YTC1
YTC1
FS YTC1
YTC1
cables YTC1 YTC1
FS
FS
FS
FS
cables
cables
04
cables
YTC1 cables
Black
FS
cables
00
cables
To show the colour required please replace xx in the part number with:
FS
YA1TC2
cables
38
COAXIAL Antennax Feeder Cables
Antennax Feeder Coax N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Antennax
The AntennaxTM range of high performance, ultra low loss coaxial cables are designed for interconnection of base stations, aerials and transceivers. Developed for microwave, satellite and telecommunication, Antennax coax cables are manufactured to guarantee high levels of performance across the broadband spectrum up to 5.8GHz. Antennax 50 Ohm & 75 Ohm coaxial cables can be used as a direct alternative to traditional corrugated cables while offering similar high performance, greater flexibility and faster termination with reduced risk of kinking.
The flexible braided design allows Antennax cables to be used throughout the installation, removing the need for jumper cables which are traditionally used to terminate corrugated coax cables. 75 Ohm versions are designed for use on wireless broadband video applications and specialised RF communications.
Part No.
Cable Type
Sheath Material
Size mm
Weight kg/km
O/D mm
Antennax 50 Ohm
390L40H
390L19 390L19H 390L20 390L20H 390L24
ANT-195
UV PE
1/0.94
30
4.95
ANT-195H
LSHF
1/0.94
30
4.95
ANT-200
UV PE
1/1.12
30
4.95
ANT-200H
LSHF
1/1.12
30
4.95
ANT-240
UV PE
1/1.42
50
6.1
ANT-240H
LSHF
1/1.42
50
6.1
ANT-300
UV PE
1/1.78
80
7.6
ANT-300H
LSHF
1/1.78
80
7.6
ANT-400
UV PE
1/2.74
100
10.3
ANT-400H
LSHF
1/2.74
100
10.3
ANT-600
UV PE
1/3.61
200
12.7
ANT-600H
LSHF
1/3.61
200
12.7
390L20H75
ANT-200H
LSHF
1/0.64
31
5.0
390L24H75
ANT-240H
LSHF
1/0.82
49
6.1
390L40H75
ANT-400H
LSHF
1/1.65
101
10.3
390L60H75
ANT-600H
LSHF
1/2.74
201
15.0
390L24H 390L30 390L30H 390L40 390L40H 390L60 390L60H Antennax 75 Ohm
cables
FS
FS cables
cables
FS
Full technical datasheets and test reports are available for each cable showing attenuation, return loss and resistance
FS cables
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
39
Antennax Connectors COAXIAL Antennax Feeder Coax N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
The AntennaxTM connectors are matched perfectly with the cables and minimise loss and provide easy termination either in the field or on the assembly bench. To ensure reliable weatherproof terminations a full range of tools, boots, shrouds, self amalgamating tapes and weatherproof PVC tape is also available. It’s as important to us that your installation is reliable and trouble free as it is to you. If the connector type you need is not shown please ask us as we may well be able to supply it.
Female
N-Type Crimp Male
Crimp Tool
Stripping Tool
390L19 -CS7
390L24 -T1
390L24 S1
-
-
390L24 -T1
390L24 -S1
390L24 -CS1
390L24 -CS6
390L24 -CS7
390L24 -T1
390L24 -S1
-
-
-
-
390L30 -T1
390L40 S1
390L40 -CT6
390L40 -CT7
390L40 -CS1
390L40 -CS6
390L40 -CN7
390L40 -T1
390L40 -S1
390L60 -CT6
390L60 -CT7
-
-
-
390L60 TS1
-
-
-
-
-
-
cables
BNC Crimp Male
TNC Crimp
SMA Crimp
-
-
-
-
-
FS
-
-
-
-
Female
Right Angle Male
Male
Female
Reverse Polarity Male
Reverse Polarity Female
Male
Reverse Polarity Male
Reverse Polarity Female
390L19 -CN1
390L19 -CN2
390L19 -CN3
-
-
-
-
-
390L19 -CS6
390L20 390L20 -CB1 -CB2
390L20 -CN1
390L20 -CN2
390L20 -CN3
390L20 390L20 -CT1 -CT2
390L20 -CT6
390L20 -CT7
-
390L24 390L24 -CB1 -CB2
390L24 -CN1
390L24 -CN2
390L24 -CN3
390L24 390L24 -CT1 -CT2
390L24 -CT6
390L24 -CT7
-
390L30 -CN1
390L30 -CN2
-
-
390L40 -CN1
390L40 -CN2
390L40 -CN3
390L60 -CN1
390L60 -CN2
-
Connectors & Accessories -
-
-
390L40 390L40 -CB1 -CB1
-
-
390L40 390L40 -CT1 -CT2
-
-
-
-
-
390L2075 390L2075 -CN1 -CN2
-
390L2075 -CT1
390L2075 -CT2
-
-
-
-
-
390L2475 390L2475 -CN1 -CN2
-
390L2475 -CT1
390L2475 -CT2
-
-
-
-
-
390L4075 390L4075 -CN1 -CN2
-
390L4075 -CT1
390L4075 -CT2
-
-
-
-
-
390L6075 390L6075 -CN1 -CN2
-
390L6075 390L6075 -CT1 -CT2
-
-
-
FS
-
cables
-
-
cables
FS
FS
FS
FS
FS
cables
cables
cables
FS
Please note ANT-600 connectors are clamp style
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
40
HOME AUTOMATION HD Media Composite Cables
HD Media Composite Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Developed to carry HD Video, HDMI and high speed data, all the components in these cables have been developed with both the present and future in mind. By combining all elements within a single tough jacket these HD Media Composite Cables are far less likely to get kinked or damaged during installation and allow general electrical contracting labour to pull in the carcass wiring. The distinctive jacket colour of these cables also enables quick and easy identification. The coaxial cables use a pure copper core with high braid coverage and bonded aluminium foil tape to give outstanding screening performance. The Cat-5 and Cat-6 cables carry signals at rates far in excess of the standard which allows for large file transfer between devices quickly and without corruption. Additionally, with cables containing fibre or building control elements such as KNX, Crestron™, Mode™ or Lutron™ you can be confident that the future is available now. Cables are printed with the area and device numbers on the jacket to make marking or tagging during installation quick and simple. If you have a specific requirement that is not shown please ask as it may have been added since the catalogue was printed. It may also be possible to manufacture it to your requirement in small quantities and with a lead time of only a few weeks.
HD Media Composite Cables
HA1
cables
FS
FS
HA1
HA2
HA3
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Blue Cat 5E UTP 1 x Red Cat 5E UTP Pink Overall PVC Sheath with a White Stripe Overall Diameter: 16.8mm Weight: 210kg/km
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Blue Cat 5E UTP 1 x Red Cat 5E UTP 1 x Grey building Control & Lighting Cable Pink Overall PVC Sheath with a Blue Stripe Overall Diameter: 19.5mm Weight: 270kg/km
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP Pink Overall PVC Sheath with a Black Stripe Overall Diameter: 17.3mm Weight: 220kg/km
HA4
HA5
HA6
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Blue Cat 5E UTP Pink Overall PVC Sheath with a Green Stripe Overall Diameter: 18.7 Weight: 250kg/km
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Blue Cat 5E UTP Pink Overall LSHF Sheath with a Violet Stripe Overall Diameter: 18.7 Weight: 250kg/km
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Orange Fibre Pink Overall PVC Sheath with a Brown Stripe Overall Diameter: 16.6mm Weight: 235kg/km
cables
HA7
cables
FS
FS cables
1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Green KNX Pink Overall PVC Sheath with a Yellow Stripe Overall Diameter: 18.4mm Weight: 260kg/km
www.fscables.com
sales@fscables.com
41
HD Media Composite Cables HOME AUTOMATION Technical Specifications for each element Coaxial Cable Conductor: Dielectric: 1st Screen: 2nd Screen: 3rd Screen: 4th Screen: Sheath:
Bare Copper Foamed PE Bonded Aluminium Foil Aluminium Wire Braid Aluminium Foil Aluminium Wire Braid PVC
Overall Diameter: 7.54mm Impedance: 75 Ohm Nominal Capacitance: 52 pF/Ft ±3 Velocity: 85% Return Loss: ≥ 20dB
Attenuation: 55MHz 5.25 dB/100m 450MHz 14.43 dB/100m 1000MHz 21.49 dB/100m 1800MHz 27.73 dB/100m 3000MHz 37.50 dB/100m
Overall diameter: Impedance:
5.3mm 100 Ohm ±15
Attenuation: 1MHz 2.0 dB/100m 4MHz 4.1 dB/100m 10MHz 6.5 dB/100m 16MHz 8.2 dB/100m 20MHz 9.3 dB/100m 31.25MHz 11.7 dB/100m 62.5MHz 17.0 dB/100m 100MHz 22.0 dB/100m
Overall diameter: Impedance:
6.4mm 100 Ohm ±15
Attenuation: 1MHz 1.9 dB/100m 4MHz 3.7 dB/100m 10MHz 5.9 dB/100m 16MHz 7.5 dB/100m 20MHz 8.4 dB/100m 31.25MHz 10.6 dB/100m 62.5MHz 15.4 dB/100m 100MHz 19.8 dB/100m 155MHz 25.1 dB/100m 200MHz 29.0 dB/100m 250MHz 32.8 dB/100m
HA5
Cat 5E 4Pair UTP PVC Conductor: Solid bare copper 0.51mm Insulation: PE Sheath: PVC Complies to TIA/EIA 568B & ISO/IEC 11801
Cat 6 4Pair UTP PVC Conductor: Solid bare copper 0.570mm Insulation: PE Sheath: PVC
Complies to TIA/EIA 568B & ISO/IEC 11801
No. of Fibres:
4
FS
Fibre Size:
50/125µ
Other fibre combinations and sizes are available to order including 9/125 & 62.5/125, please contact us for more details.
FS
FS
cables
cables
FS
cables
Fibre
cables
Building Control Lighting Cable Conductor: Insulation: Sheath:
22(7)AWG tinned copper PE Foil screened pair with drain wire
Tel: 01727 840 841
18(7) AWG tinned copper PVC PVC
Fax : 01727 840 842
FS
FS
FS
FS
cables
cables
Power Cores – Black & Red
Conductor: Insulation: Screen:
cables
Data Pair – White & blue
cables
42
BUS Industrial & Building Control Databus速 Foundation Fieldbus ISA/SP-50 Profibus PA Type A A single pair 18AWG bi-directional digital Fieldbus cable for type A applications (31.25 KBits/sec) available in PVC, LSHF and SWA versions. Part No.
1801POFOH 1801PODF 1801POFO 1801POFOH 1801POFOA
Alt. to Belden
No. of Pairs
AWG
Sheath Material
Weight kg/km
O/D mm
Screened
Sheath Colour
3076F LSHF SWA
1 1 1 1
18(1) 18(7) 18(7) 18(7)
PVC PVC LSHF SWA/PE
75 51 51 246
8.0 6.4 6.4 9.6
Yes Yes Yes Yes
Blue Orange Orange Black
Databus速 Foundation Fieldbus ISA/SP-50 Type B A single pair 22AWG bi-directional digital Fieldbus cable for type B applications (31.25 KBits/sec) available in PVC, LSHF and SWA versions. Part No.
Alt. to Belden
No. of Pairs
AWG
Sheath Material
Weight kg/km
O/D mm
Screened
2201POFO 2201POFOH 2201POFOA
3077F LSHF SWA
1 1 1
22(7) 22(7) 22(7)
PVC LSHF SWA/PE
29 29 213
4.9 4.9 8.1
Yes Yes Yes
Databus速 Foundation Fieldbus ISA/SP-50 High Speed A high speed single pair 22AWG bi-directional digital Fieldbus cable for 1.0 & 2.5MBit/sec applications available in PVC, LSHF and SWA versions.
cables
FS
FS cables
cables
FS
FS cables
Part No.
Alt. to Belden
No. of Pairs
AWG
Sheath Material
Weight kg/km
O/D mm
Screened
2201POFF 2201POFFH 2201POFFA
3078F LSHF SWA
1 1 1
22(7) 22(7) 22(7)
PVC LSHF SWA/PE
65 65 287
9.4 9.4 12.6
Yes Yes Yes
CAN Bus Cables CAN Bus (Control Area Network) is a non-addressable system which treats all devices as equal allowing for fast transmission of data. Due to its robust nature it has been widely adopted in the automotive industry. While all the types listed below are for high flexing automation applications, static versions can also be supplied. Part No.
28100201 28100202 28100301 28100302 28100501 28100502
No. of Pairs
CSA mm2
Sheath Material
Weight kg/km
O/D mm
Screened
1 2 1 2 1 2
0.22 0.22 0.34 0.34 0.50 0.50
PUR PUR PUR PUR PUR PUR
41 60 53 64 67 75
5.2 8.0 5.9 6.5 7.2 9.0
Yes Yes Yes Yes Yes Yes
Low Smoke Halogen Free
SWA
www.fscables.com
sales@fscables.com
43
Industrial & Building Control BUS CC-Link 1.10 FieldLink® Cables Developed by Mitsubishi, CC-Link allows high speed communication between controllers and field devices. CC-Link is particularly popular in Asia and is used worldwide for time critical applications in conjunction with Mitsubishi Automation products. CC-Link is certified by CLPA and ensures product compatibility. Part No.
2003CODF-03 2003CODFA
Alt. to Belden
No. of Cores
AWG
Sheath Material
Weight kg/km
O/D mm
Screened
YR47205 SWA
3 3
20 20
PVC SWA/PE
186 276
7.6 12.0
Yes Yes
2003CODF-03
N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC DeviceNet™ Thick Cables 60331)
Designed for use on Allen Bradley DeviceNet systems, the ‘thick’ cable construction incorporates a power and data pair for backbone wiring. Several sheathing options are available for different installation environments. These cables are also referred to as DeviceNet Trunk cables. Part No.
15ABDY 15ABDR 15ABDYA 15ABDY-HF
Alt. to Belden
3082A 3083A SWA Hi-FLEX
Pairs x AWG
P: 1Px15 P: 1Px15 P: 1Px15 P: 1Px15
D: 1Px18 D: 1Px18 D: 1Px18 D: 1Px18
Sheath Material
Weight kg/km
PVC CPE SWA/PE PUR
174 174 359 209
O/D mm
Appl.
12.2 Static 12.1 Static 16.1 Static 12.1 Dynamic
Screened
Yes Yes Yes Yes
N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC DeviceNet™ Thin Cables 60331) ‘Thin’ cables are designed to connect sensors, actuators and switches to the DeviceNet backbone
15ABDY
(thick cable) on the Allen Bradley DeviceNet system. Similar in construction to the backbone cable, the ‘thin’ cable incorporates a power and data pair. Several sheathing options are available for different installation environments. These cables are also referred to as DeviceNet Drop cables.
22ABDY 3084A 22ABDR 3085A 22ABDYA SWA 22ABDY-HF Hi-FLEX
Pairs x AWG
P: 1Px22 P: 1Px22 P: 1Px22 P: 1Px22
D: 1Px24 D: 1Px24 D: 1Px24 D: 1Px24
Sheath Material
Weight kg/km
O/D mm
PVC CPE SWA/PE PUR
65 68 240 64
7.0 7.1 11.9 7.0
Appl.
Static Static Static Dynamic
FS
Screened
Yes Yes Yes Yes
FS
cables
FS
FS
FS
FS
FS
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
SWA
FS
cables
Alt. to Belden
cables
Part No.
cables
44
BUS Industrial & Building Control Bus Cables Echelon LonWork System Cabling
2202POFGH
A range of single pair Bus cables is available for the LonWork’s system allowing convenient wiring via the Free Topology concept. Due to the popularity of the system for building management applications in the public sector these cables are now stocked in Low Smoke Halogen Free versions. Duct grade and SWA options can also be manufactured for quantities as low as 100m. Part No.
Alt. to Belden
No. of Pairs
AWG
Sheath Material
1601PUY 1601PUYH 1601PUYD 1601PUYA
8471 LSHF DUCT SWA
1 1 1 1
16(19) 16(19) 16(19) 16(19)
Weight kg/km
PVC LSHF LDPE PE
56 56 89 280
O/D mm
Screened
7.0 7.0 9.5 10.8
No No No No
Echelon LonWork System Cabling Designed for use on industrial and commercial Bus systems, these cables have become increasingly popular on Building Management Systems (BMS). Available as one and two pair cables, screened and unscreened in Low Smoke Halogen Free, they provide the ideal low cost solution to Bus wiring. Part No.
2201PUGH 2202PUGH 2201POFGH 2202POFGH
C5S-HF
Alt. to Belden
No. of Pairs
AWG
7701NH 7702NH 7703NH 7704NH
1 2 1 2
22(1) 22(1) 22(1) 22(1)
Sheath Material
LSHF LSHF LSHF LSHF
Weight kg/km
O/D mm
Screened
14 27 23 36
3.5 5.0 4.5 6.5
No No Yes Yes
N2XCH-FE180/E90: Screened, Industrial EthernetXLPE/Cu/LSHF Cables to IEEE 802.3 Fire Resistant (IEC 60331)
Through the use of Category 5 style cables Industrial Ethernet provides a stable platform for linking automation systems and workstations. They are also suitable for interlinking different Bus protocols such as Profibus and Interbus. The use of finely stranded conductors and PUR sheathing compounds makes them ideal for frequent flexing and dynamic applications.
cables
FS
FS cables
Part No.
C52S-HF C5S-HF
No. of Pairs
AWG
Sheath Material
Weight kg/km
O/D mm
Screened
2 4
24(19) 24(19)
PUR PUR
65 82
6.1 8.0
Yes Yes
Interbus Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC The Interbus open ring topology allows integration of different field devices from control level down 60331) to sensor switches over one system. Unlike traditional ring systems Interbus uses one cable to route data back and forth to all devices. Each device or unit will amplify the signal before sending it on to the next station. The data is transmitted over a 3 pair screened cable. For remote applications a composite data and power cable is available.
cables
FS
FS cables
Part No.
2403POBP 2403POBP-HF 2403/3POBP-HF
Alt. to Belden
Pair x mm2
Sheath Material
O/D mm
Application
Screened
PVC PUR PUR
8.0 8.2 9.3
Static Dynamic Dynamic with remote power
Yes Yes Yes
N/A 3P x 0.22 3102A 3P x 0.22 3119A 3P x 0.22 + 3C 1.0
Low Smoke Halogen Free
Duct Grade
SWA
www.fscables.com
sales@fscables.com
45
Industrial & Building Control Bus Cables BUS Modbus Developed by Modicon, Modbus provides a master/slave communication between intelligent automation devices. Based on Belden 9841, the Modbus cable has an increased jacket thickness to ensure a correct termination into the Modbus connectors.
2201PODF Part No.
Alt. to Belden
2401POHP+ YM29560 2401POHPH+ LSHF
No. of Pairs
AWG
Sheath Material
Sheath Colour
Weight kg/km
O/D mm
Screened
1 1
24(7) 24(7)
PVC LSHF
Grey Grey
63 63
6.7 6.7
Yes Yes
Profibus DP IEC 61158/EN 50170 SINEC L2 A range of single pair Bus cables for process and field communication in cell networks. The Profibus protocol has been widely adopted for production and process automation applications providing transmission rates up to 12Mbits/sec. Part No.
Alt. to Belden
No. of Cond Pairs mm
2201PODF 3079A 2201PODFHA SWA 2201PODFHQ LSHF 2201PODFD DUCT 2201PODFHF Hi-FLEX 2201PODF7 3079E 2201PODFHT HiTEMP
1 1 1 1 1 1 1
0.64 0.64 0.64 0.64 0.64 0.64 0.64
Sheath Material
Sheath FastConn/ Weight Colour Quickstrip kg/km
PVC LSHF LSHF LDPE PUR PVC FEP
Violet Black Violet Black Violet Violet Violet
Yes No Yes No No No No
62 188 64 88 78 65 64
O/D mm
Application
8.0 Static 11.5 Static 8.0 Static 9.5 Wet/outdoor static 8.3 Dynamic 8.0 European type static 7.2 High Temperature
28100703
N2XCH-FE180/E90: Pilz Safety Bus p XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) ® ®
No. of Cores
28100703 28100703H 28100703-HF
3 3 3
CSA mm2
0.75 0.75 0.75
FS
Sheath Material
Sheath Colour
Weight kg/km
O/D mm
Application
PVC LSHF PUR
Yellow Yellow Yellow
89 89 89
7.5 7.5 7.5
Light Flexing Light Flexing Dynamic
cables
Part No.
FS
cables
Safety Bus p is an open Fieldbus system based on well established CAN Bus technology. Safety Bus p® modules must be self monitoring, perform intelligent checks and react independently, therefore remaining ‘safe’. Several versions of Safety Bus p® cables are available depending on the application and environmental conditions.
cables
FS
FS
FS
FS
FS
cables
cables
cables
FS
All trademarks & tradenames are acknowledged. Low Smoke Halogen Free
Duct Grade
Tel: 01727 840 841
SWA
Fax : 01727 840 842
cables
cables
46
BUS System Specific Lighting Control Cables Lutron GRX-CBL-346S Grafik Eye Cables
18/22LCCH
Lutron are world leaders in lighting control systems for prestige residential properties as well as restaurant, retail and commercial applications. In addition to the full range of genuine Lutron cables we are also able to offer a high quality alternative to the GRX-CBL-346S for the GRAFIK Eye® 3000, 4000, 5000 & 6000 systems manufactured using Low Smoke Halogen Free materials throughout. This enables installations in locations that prohibit the use of standard PVC types. Where the cable is run outside duct grade and armoured versions are also popular.
Cable Construction - Power Pair
Technical Information
Conductors: Insulation:
Voltage Rating: Test Voltage: Temperature Rating: Smoke Emission: Halogen Emission:
Colour code: Conductor resistance:
18(7)AWG tinned copper strands Polypropylene insulation – 1.97mm nominal Red & black 23 Ohm/km @ 20°C
300V 1.5kV 0°C to +70°C IEC 61034-1 & 2 IEC 60754-1 & 2
Cable Construction - Data Pair Conductors: Insulation:
22(7)AWG tinned copper strands Polypropylene insulation – 1.83mm nominal Aluminium/polyester screen and 24(7)AWG TCu drain wire Purple & white 58 Ohm/km @ 20°C Core to core 45pF/m nominal 120 Ohm nominal
Screen: Colour code: Conductor resistance: Capacitance: Impedance:
Pair bundles laid up with polyester fillers, polyester tape, blue LSHF sheath.
18/22ECCH
cables
FS
FS cables
cables
FS
FS cables
Part No.
Alternative to
Sheath Colour
O/D mm
Weight kg/km
18/22LCCH 18/22LCCHD 18/22LCCHA
Lutron GRX CBL-346S Duct Grade SWA/PE
Blue Black Black
8.4 10.8 12.3
72 123 259
Mode Lighting Cable N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC If you are installing a Mode Lighting Evolution system we offer an alternative to Belden 1502R. 60331) The cable is electrically the same as the Lutron type above but uses a PVC jacket with a reduced overall diameter for easy routing. Part No.
18/22ECC 18/22ECCH 18/22ECCD 18/22ECCA
Alternative to
Sheath Colour
O/D mm
Weight kg/km
Blue Blue Black Black
6.4 6.4 8.7 10.5
65 65 89 223
Belden 1502R LSHF Duct Grade SWA/PE
Low Smoke Halogen Free
Duct Grade
SWA
www.fscables.com
sales@fscables.com
47
KNX BUS
With the increasing demand for ‘green’ buildings, Intelligent Building Technology systems can contribute to significant energy savings over time. The operation and control of heating, lighting and air condition among others can be aligned with external climate conditions or adjusted by an interface to pre-set levels.
31000502H
FS Cables as member of the KNX association now offers KNX certified cable. This features two twisted pairs of solid conductor with a foil screen and tinned copper drain wire in a green LSHF jacket. It has been tested and certified as being suitable for use in KNX systems and bears the KNX logo. All KNX certified equipment has been tested and certified to meet this high standard and only equipment meeting this can carry the logo. This ensures the quality, reliability and guaranteed compatibility of all KNX devices and equipment.
Part No.
No. of Pairs
Conductor mm
Sheath Colour
Weight kg/km
O/D mm
KNX Reg No
KNX Cable 31000501QH
1 Quad
0.8
Green
57
6.2
N/A
31000502H
2
0.8
Green
62
6.8
150/8928/10
31000502H04
2
0.8
White
62
6.8
150/8928/10
31000502D
2
0.8
Black
95
9.2
150/8928/10
31000502A
2
0.8
Black
300
13.0
150/8928/10
No. of Pairs
Conductor mm
31000501*
1
0.8
31000501H
1
0.8
31000501H190
1
0.8
31000501H320
1
0.8
Part No.
Sheath Colour
Sheath Material
Length
O/D mm
Grey
PVC
Bulk
5.9
Green
LSHF
Bulk
5.2
Green
LSHF
190mm
5.2
Green
LSHF
320mm
5.2
31000502A
KNX Jumper Cables
FS
FS
cables
FS
FS
FS
FS
FS
Duct Grade
Tel: 01727 840 841
SWA
Fax : 01727 840 842
cables
cables
cables
cables
Low Smoke Halogen Free
cables
FS
cables
* This jumper cable has the colour code of black & red.
cables
48
BUS Simmtronic Specs 3 Simmtronic Specs 3 & Lighting Multicores
1801PUYH-01
FS Cables are the sole appointed supplier of the Simmtronic SPECS3 cables. Manufactured to very high tolerances using Low Smoke Halogen Free compounds throughout you can be confident the cable will fit the connectors first time and every time, resulting in a trouble free installation you can rely on. Be careful of imitations, only use the authentic Simmtronic Specs 3 cable printed with the Simmtronic logo. For more information, please go to www.simmtronic.com or call 01992 456 869.
Construction
Plain copper wire strands, class 5 to BS6360, LSHF insulation - colour coded, LSHF sheath - White. 300/500V. -20째C to +90째C static.
C-Bus grey 2201POFPH-05 1 pair 22AWG screened cable for connection of SPX 310 area controllers and SPG.2 gateway modules. Low Smoke Halogen Free throughout. 1801PUYH-04
E-Bus white 1801PUYH-04 1 pair 18AWG unscreened cable for connection of intelligent remote devices to SPX 310 area controllers and SPV.9 lighting control modules. Low Smoke Halogen Free throughout.
O-Bus/M-Bus pink 1801PUYH-07 1 pair 18AWG unscreened cable for communications from the SPX 310 area controller and the SPV.9 lighting control modules. Low Smoke Halogen Free throughout.
E-Bus blue 1801PUYH-01 1 pair 18AWG unscreened cable. Colour coded blue for fast identification this version of E-Bus provides emergency monitoring signals to the SPX 310 area controller or for identification of specific circuits spec 3 system. Low Smoke Halogen Free throughout.
T-Bus grey cables
FS
1801PUYH-07
FS cables
cables
FS
FS cables
2202PTFRH 2 pair 22AWG individual and overall foil screen for dual connections of SPX310 area controllers and SPG.2 gateway modules. Low Smoke Halogen Free throughout.
SPV.9 Plug wiring A full range of Low Smoke Halogen Free flexible cables are available from stock for wiring three and six pin Ensto plugs allowing fast onsite installation. Stocked in either 1mm2 or 1.5mm2. Part No.
31801003 31801503 31801004 31801504 31801005 31801505 31801006 31801506
Cores x mm2
Weight kg/km
O/D mm
3 x 1.0 3 x 1.5 4 x 1.0 4 x 1.5 5 x 1.0 5 x 1.5 6 x 1.0 6 x 1.5
84 120 106 152 134 183 163 201
7.1 8.3 7.9 9.4 8.7 9.4 9.8 10.1
www.fscables.com
sales@fscables.com
49
AUDIO TruSound Microphone & Snake Cables Microphone Cables
Microphone cables come in many shapes and sizes. Super flexibility even at low temperatures is achieved through the use of a special insulation and highly flexible cotton fillers to maintain a constant capacitance and avoid noise when the cable flexes. The spiral copper shield offers excellent screening whilst remaining flexible and providing mechanical support when the cable is under physical stress. The four core microphone cables are a star quad format.
Part No.
Cores x mm2
Stranding No. x mm
Weight kg/km
O/D mm
Colour
TSM02020
2 x 0.22
28 x 0.10
45
5.9
Black
TSM02040
4 x 0.22
28 x 0.10
55
6.5
Black
TSM03020
2 x 0.34
40 x 0.10
52
6.2
Black
TSM03040
4 x 0.34
40 x 0.10
64
6.8
Black
TSM05020
2 x 0.50
28 x 0.15
65
6.7
Black
TSM05040
4 x 0.50
28 x 0.15
75
7.2
Black
TSM02020
Multiple Star Quad Cables Designed for longer runs where it is beneficial to run a number of signals down a single cable using the star quad format. These cables are highly flexible and robust enough for touring applications. Cores x mm2
Stranding No. x mm
Screening
Weight kg/km
O/D mm
Colour
TSQ01010
1 x 4 x 0.15
19 x 0.10
Overall Braid
45
5.5
Black
TSQ02010
1 x 4 x 0.22
28 x 0.10
Overall Braid
60
6.5
Black
TSQ01040
4 x 4 x 0.15
19 x 0.10
Overall Braid
180
11.7
Black
TSQ01080
8 x 4 x 0.15
19 x 0.10
Overall Braid
280
14.9
Black
TSQ01012
12 x 4 x 0.15
19 x 0.10
Overall Braid
420
18.2
Black
TSQ01024
24 x 4 x 0.15
19 x 0.10
Overall Braid
780
25.0
Black
TSQ01010H
1 x 4 x 0.18
7 x 0.18
Overall Foil
50
4.7
Black
TSQ05010H
1 x 4 x 0.50
28 x 0.15
Overall Braid
60
6.5
Black
TSQ01040H
4 x 4 x 0.18
7 x 0.18
Overall Foil
150
11.4
Grey
TSQ01080H
8 x 4 x 0.18
7 x 0.18
Overall Foil
290
15.5
Grey
TSQ01012H
12 x 4 x 0.18
7 x 0.18
Overall Foil
425
19.3
Grey
LSHF versions are also offered for use in sensitive areas or where local regulations permit.
cables
Multipair versions up to 30 pair are available with or without individual pair screens.
FS
FS
cables
Part No.
FS
cables
FS
FS
FS
FS
FS
cables
Snake cables are shown on page 52.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
Low Smoke Halogen Free
cables
50
AUDIO TruSound Parallel Speaker Cable Parallel Speaker Cables
TS804002
Designed for installations in pubs, clubs, gyms and public buildings as well as high end domestic installations, these parallel speaker cables provide easy termination due to the longitudinal core identification. The high number of pure copper strands and low resistance values enable the speaker to operate at optimum levels. The question when specifying is to check the purity of the copper as it is this which gives the lowest resistance figure. In TruSound speaker cables only pure electrolytic copper is used so it can be classed as OFC (Oxygen Free Copper).
Technical Information Minimum Bend Radius: 5 x cable thickness Part No.
Size mm2
Stranding No. x mm
Weight kg/km
O/D mm
Cond. Resistance Ohm/km
Cap pF/m
Test Voltage
Colour
TruSound Parallel Speaker Cable TS800702
0.75
24 x 0.2
23
2.3 x 4.9
26.0
82
2kV
Clear
TS801502
1.5
189 x 0.1
42
2.8 x 5.8
13.3
67
2kV
Clear
TS802502
2.5
322 x 0.1
60
3.6 x 7.4
7.98
57
2kV
Clear
TS804002
4.0
511 x 0.1
105
4.5 x 9.7
4.95
54
2kV
Clear
TS806002
6.0
777 x 0.1
141
6.1 x 12.5
3.3
58
2kV
Clear
TS810002
10.0
1260 x 0.1
252
7.0 x 15.0
1.91
62
2kV
Clear
TruSound Low Smoke Halogen Free Parallel Speaker Cables TS800702H
0.75
24 x 0.2
23
2.3 x 4.9
26.0
82
2kV
White
TS801502H
1.5
189 x 0.1
42
2.8 x 5.8
13.3
67
2kV
White
TS802502H
2.5
322 x 0.1
60
3.6 x 7.4
7.98
57
2kV
White
TS802502H
Flat Speaker Cable
cables
FS
Low profile speaker cable, suitable for laying under carpet, behind decorative moulding, along the ceiling or under furniture. Suitable for fixed installations, this cable uses flexible PVC insulation making it easily routable. Part No.
Size mm2
Stranding No. x mm
Weight kg/km
O/D mm
Cond. Resistance Ohm/Km
Colour
TruSound Flat Speaker Cable
FS cables
TSF01502
1.5
47 x 4 x 0.1
53
12.8 x 2.4
<13.3
White
TSF02502
2.5
80 x 4 x 0.1
60
14.6 x 2.6
<7.98
White
TSF04002
4.0
125 x 4 x 0.1
108
17.5 x 0.3
<4.95
White
cables
FS
FS cables
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
51
TruSound Multicore Speaker Cable AUDIO Multicore Speaker Cable Designed for the professional these multicore speaker cables are extremely flexible due to the high rate of conductor twist and the insulation and jacket materials used. Ideal for winding on and off drums when touring, they even remain flexible at low temperatures making rigging easier. They are also ideal for large fixed installations where sound quality is important.
TSS02504
The range of conductor sizes enables long runs, or shorter runs with very low power loss.
Part No.
Cores x mm2
Stranding No. x mm
Weight kg/km
O/D mm
Cond. Resistance Ohm/km
7.0
<14
Test Voltage
Colour
TruSound Multicore Speaker Cables - Circular TSS01502
2 x 1.5
30 x 0.20
75
2kV
Black
TSS01504
4 x 1.5
30 x 0.20
120
8.6
<14
2kV
Black
TSS02502
2 x 2.5
50 x 0.25
90
7.5
<8
2kV
Black
TSS02504
4 x 2.5
50 x 0.25
175
10.0
<8
2kV
Black
TSS02508
8 x 2.5
50 x 0.25
330
14.0
<8
2kV
Black
TSS04002
2 x 4.0
56 x 0.30
170
10.5
<5
2kV
Black
TSS04004
4 x 4.0
56 x 0.30
265
13.0
<5
2kV
Black
TSS04008
8 x 4.0
56 x 0.30
495
18.5
<5
2kV
Black
TruSound Low Smoke Halogen Free Multicore Speaker Cables - Circular TSS01502H
2 x 1.5
30 x 0.25
65
7.0
<14
2kV
Black
TSS02502H
2 x 2.5
TSS02504H
4 x 2.5
50 x 0.25
85
7.6
<8
2kV
Black
50 x 0.25
145
8.8
<8
2kV
Black
TSS02508H
8 x 2.5
50 x 0.25
300
12.8
<8
2kV
Black
TSS04002H
2 x 4.0
56 x 0.30
125
9.2
<5
2kV
Black
TSS04004H
4 x 4.0
56 x 0.30
223
10.7
<5
2kV
Black
TSS06002H
2 x 6.0
84 x 0.30
170
10.6
<3
2kV
Black
FS
cables
FS
FS
FS
FS
FS
cables
FS
cables
FS
cables
Colour Code - Multicore Circular Speaker Cable: 01
Red
02
Blue
White
Cables with 7 cores and above are number coded
Low Smoke Halogen Free
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
Black
04
cables
03
cables
52
AUDIO TruSound Snake & DMX Cables Snake Cables Snake cables are multicore audio cables usually linking a number of individual microphone cables or audio feeds back to the mixing desk. Ideal for either fixed installation in permanent venues or on temporary installations when the cables will be coiled up and stored after the show.
TSD02010 Part No.
Pairs x AWG
Stranding No. x mm
Weight kg/km
O/D mm
Colour
TSSN0202
2 x 2 x 24
7 x 0.20
68
8.1
Black
TSSN0204
4 x 2 x 24
7 x 0.20
96
8.9
Black
TSSN0208
8 x 2 x 24
7 x 0.20
183
12.1
Black
TSSN0212
12 x 2 x 24
7 x 0.20
243
14.3
Black
TSSN0216
16 x 2 x 24
7 x 0.20
319
16.6
Black
TSSN0220
20 x 2 x 24
7 x 0.20
420
19.0
Black
TSSN0224
24 x 2 x 24
7 x 0.20
486
22.1
Black
TSSN0232
32 x 2 x 24
7 x 0.20
610
24.3
Black
TSSN0240
40 x 2 x 24
7 x 0.20
780
25.8
Black
TSSN0108Q
8 x 4 x 28
7 x 0.127
255
15.1
Black
DMX Cables Developed to ensure accurate transmission of digital AES/EBU audio signals and digital DMX control signals, these cables are used extensively in the entertainment industry. DMX is designed to work between 90立 and 120立 impedance. The level of shielding enables interference-free transmission even over long distances. The tough physical properties of the TruSound DMX cable make it one of the best products on the market.
Part No.
cables
FS
FS
Pairs x mm2
No. of Power Cores x mm2
Weight kg/km
O/D mm
Colour
Black
TSD02010
1 x 2 x 0.22
-
50
6.0
TSD02011
1 x 2 x 0.22
-
50
6.0
Blue
TSD02020
2 x 2 x 0.22
-
75
8.0
Black
TSD02150
1 x 2 x 0.22
3 x 1.5
175
11.6
Black
TSD02250
1 x 2 x 0.22
3 x 2.5
220
13.3
Black
TSD02270
2 x 2 x 0.22
3 x 2.5
380
18.3
Black
TSD021110
4 x 2 x 0.22
3 x 1.5
375
17.4
Black
TSD022110
4 x 2 x 0.22
3 x 2.5
460
19.3
Black
cables
cables
FS
Please note some of the cables above are also available in Low Smoke Halogen Free.
FS cables
www.fscables.com
sales@fscables.com
53
TruSound S-Video & HDMI Cables AUDIO S-Video Cable Using two coaxial cables within one jacket this flexible S-Video cable is suitable for connection of cameras, computers, audio, video & TV units. Each coax is screened with an aluminium foil and high coverage tinned copper wire braid and coloured pvc jacket for easy identification.
TSSV0802 Construction
Technical Information
Fine tinned copper strands 28(7)AWG, foam
Impedance: Capacitance Core to Screen: Temperature Range:
polyethylene insulation, aluminium foil, tinned
75 Ohms +/- 3% 64 pF/m -15°c to +70°C
copper wire braid, PVC jacket. Two cables laid together and circular black PVC sheathed. Part No.
Cores x mm2
Stranding
Weight kg/km
O/D mm
Colour
2 x 0.08
7 x 0.12
70
7.5
Black
TruSound S-Video TSSV0802
HDMI Cable The FSC range of high quality HDMI cables offer a quick and easy way to link devices throughout a building. Supplied either as bulk cables or more convenient to use, made up leads. You can be sure of a clear signal transmission.
Construction
TSHMM02
Fine tinned copper strands 24(7)AWG, foam polyethylene insulation, cores twisted into pairs, each pair overall foil screened in contact with tinned copper drain wire. Fine tinned copper strands 24(7)AWG, polypropylene insulation. Pairs and cores laid together, overall aluminium foil screen and overall tinned copper wire braid, PVC black sheath. Part No.
Weight kg/km
O/D mm
Colour
4 x 2 x 0.22mm² + 7 x 0.22mm²
130
10.0
Black
HDMI plug with solder pins
-
-
-
TSH00215 TSH00215-C1 Part No.
TSHMM02
HDMI 1.3 Male to HDMI 1.3 Male
2m
TSHMM03
HDMI 1.3 Male to HDMI 1.3 Male
3m
TSHMM05
HDMI 1.3 Male to HDMI 1.3 Male
5m
TSHMM10
HDMI 1.3 Male to HDMI 1.3 Male
10m
TSHMM15
HDMI 1.3 Male to HDMI 1.3 Male
15m
TSHMM20
HDMI 1.3 Male to HDMI 1.3 Male
20m
TruSound HDMI Pre-Made Leads
Tel: 01727 840 841
Fax : 01727 840 842
FS
FS
cables
FS
FS
FS
FS
FS
cables
cables
cables
Length
cables
Description
cables
FS
TruSound HDMI Cable & Plug
cables
Description
cables
54
FIRE & SECURITY Fire Alarm Cable
Fire Alarm Cable Standard & Enhanced It is now recognised that in some buildings the continued functioning or circuit integrity of some cables is essential in providing sufficient time for evacuation. The requirements divide ‘soft skin’ cables into 2 groups, Standard and Enhanced. The ‘enhanced’ versions shown below are suitable for installation where evacuation may be delayed, for example in hospitals or high-rise buildings without sprinklers. The ‘enhanced’ group of cables offer a viable alternative to MICC (Mineral Insulated Copper Clad) in many applications with the benefit of faster installation and easier routing. Standard Construction Solid plain copper conductor, flame retardant Low Smoke Halogen Free insulation. Metallic barrier tape with copper earth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath.
38701502E
Technical Information Conductors: Voltage Rating: Resistance to Fire Alone: Resistance to Fire with Water: Resistance to Fire with Mechanical Shock: Approvals:
387E01504E cables
FS
Copper wire to BS 6360 or IEC 60228 300/500V IEC 60331: 3 hours at 750°C, BS 6387 Cat. C: 3 hours at 950°C BS 6387 Cat. W: 15 mins at 650°C, plus 15 mins with water spray BS 6387 Cat. Z: 15 mins at 950°C with mechanical shock BASEC, LPCB, BS7629: Part 1 BS 5839:1 2002 & EN 50200 Standard Grade
Part No.
Cores x mm²
O/D mm
Weight kg/km
38701002E 38701003E 38701004E 38701502E 38701503E 38701504E 38702502E 38702503E 38702504E
2 E 1.0 3 E 1.0 4 E 1.0 2 E 1.5 3 E 1.5 4 E 1.5 2 E 2.5 3 E 2.5 4 E 2.5
7.9 8.2 8.7 8.0 8.3 9.5 9.1 9.8 11.3
80 93 120 98 121 148 139 179 205
Gland
Clip
G251 G251 G251 G251 G251 G252 G252 G252 G252
RCH34 RCH34 RCH37 RCH37 RCH43 RCH47 RCH47 RCH51 RCH54
Standard pack size 100m or 500m. Other sizes are available to order. Also available in black and orange. Enhanced Construction
FS
Plain copper conductor, circuit integrity Low Smoke Halogen Free insulation, metallic barrier tape with copper earth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath. Standards:
cables
cables
FS
FS cables
BS 6387 BS 5839 - 1 BS EN 50200 BS 8434-2:2003 IEC 60332-3
C, W & Z 2002 Enhanced Grade Classification PH 120 120min duration Parts 1 & 3
Part No.
Cores x mm²
O/D mm
Weight kg/km
Part No.
387E01002E
2 E 1.0
7.9
80
387E01504E
387E01003E
3 E 1.0
8.2
93
387E02502E
387E01004E
4 E 1.0
8.7
120
387E01502E
2 E 1.5
8.0
387E01503E
3 E 1.5
8.3
O/D mm
Weight kg/km
4 E 1.5
9.5
148
2 E 2.5
9.1
139
387E02503E
3 E 2.5
9.8
179
98
387E02504E
4 E 2.5
11.8
205
121
387E04002E
2 E 4.0
12.1
269
www.fscables.com
Cores x mm²
sales@fscables.com
55
Firetuf Data & Coaxial FIRE & SECURITY Firetuf Data & Coaxial
Firetuf Data is a group of high performance fire survival data cables manufactured by Draka and designed to carry on functioning even in the event of a fire. This allows safe monitoring of evacuation routes without putting lives at risk. The twisted pair cables provide high data transmission rates and have been developed to mimic Cat-5 cabling as closely as possible. Increasingly popular with system integrators for BMS applications, the cables can be terminated using traditional LAN Insulation Displacement Connectors (IDC) making them ideal for use in horizontal backbone wiring systems in offices and public buildings. Where video is carried the coax performs in a similar way to RG59 which is widely used in the CCTV sector. This allows continued monitoring of fire exits and evacuation routes in the event of a fire. BNC connectors part no. YFTCBC1# are available to suit Firetuf Coax. Where people and property come first the Draka Firetuf Data cable range provides the ideal solution. Technical Information Design:
Generally to ISO/IEC 11801:95, EN 50173 95 and EN 50288-2-1. Suitable for standard insulation displacement connector L.A.N. sockets. RS-485 10Mb/s
Flame Retardant: Smoke Emission: Halogen Emission: Fire Resistant:
IEC 60332-1-2, EN 60332-1-2, IEC 60332-3-24C, EN 60332-3-24C, BS 4066 part 3 IEC 61034-2, EN61034-2, BS EN 50268-2 IEC 60754-1, EN 50267-2-1, IEC 61034-2, EN 50267-2-2, LU 1-085 A2 - toxic fume emissions BS 5839 Clause 26.2E > 2hrs @ 950°C BS 6387 > 3hrs @ 950°C IEC 60331-23 > 3hrs @ 750°C BS EN 50200 > 3hrs @ 950°C BS EN 50200:2000 BS 8438-2:2003 BS 8438-2 Class PH120 (120 minutes) BS 5839-1 2002 +A2 2008
387FTD403
London Underground Standard: LU 1-085-A2 fire safety performance of materials. Approved for use below ground without restriction. Firetuf Data Construction
Draka Part No.
Type
FS
Screen
Sheath
Weight kg/km
O/D mm
6.8
387FTD103
910234 1 Pair 0.63mm [22(1)AWG]
Foil & braid
LSHF Red
48
387FTD203
910244 2 Pair 0.63mm [22(1)AWG]
Foil & braid
LSHF Red
97
387FTD403
910245 4 Pair 0.63mm [22(1)AWG]
Foil & braid
LSHF Red
122
Firetuf Coax Construction
FS
cables
FSC Part No.
cables
22(1)AWG solid plain copper conductor, PE/silicone rubber composite insulation, cores twisted into pairs, pairs laid up, woven glass tape, aluminium screen in contact with stranded tinned copper drain wire, tinned copper wire braid, Low Smoke Halogen Free sheath - red. Colour code : Chart 5 (Western Electric)
387FTD5903
8.1
FS
10.4
cables
FS cables
1/0.65mm solid plain copper conductor, PE/silicone rubber composite dielectric, woven glass tape, two plain copper wire braids, Low Smoke Halogen Free sheath – red Draka Part No.
Type
Screen
Sheath
Weight kg/km
O/D mm
387FTD5903 YFTCBC1# YTC10
660096 -
75Ohm Coax 1/0.65mm BNC Connector BNC Crimp tool
Double braid -
LSHF Red -
110 -
9.1 -
cables
FS
FS
cables
FSC Part No.
Due to the unique size of Firetuf Coax special BNC connectors have been designed as standard types do not fit.
Tel: 01727 840 841
Fax : 01727 840 842
FS
cables
FS cables
56
FIRE & SECURITY Access Control Access Control N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable â&#x20AC;&#x201C; 0.6/1kV Specifically designed for proprietary access control systems, these cables are widely used in public buildings including hospitals, government and local authority offices as well as commercial and retail organisations where security and safety are important.
3993P9CHP The Low Smoke Halogen Free versions ensure minimum risk in the event of fire to both property and personnel.
Composite Access Control - Purple Pipe 3993P9CHP Construction Pair 1:
1 twisted pair 20(7)AWG tinned copper strands, foam PE insulation, 20(7)AWG tinned copper drain wire, aluminium/polyester foil. Colour code: Black/green.
Pairs 2 & 3: 2 twisted pairs 22(7)AWG tinned copper strands, foam PE insulation, 22(7)AWG tinned copper drain wire, each individual pair aluminium/polyester foil screened. Pair colour code: Black/red & black/white. Cores:
9 single cores 22(7)AWG tinned copper wire strands, solid polypropylene insulation. Colour code: Black, white, red, green, brown, blue, orange, yellow, purple. Overall Screen: aluminium/polyester foil, 22(7)AWG tinned copper drain wire.
Sheath:
Low Smoke Halogen Free, purple.
Part No.
3993P9CHP
Alt. to Belden
No. of Pairs
AWG
Screen type
Weight kg/km
O/D mm
-
-
-
-
114
9.1
Alt. to Belden
No. of Pairs
AWG
Access Control
2202PIFR
cables
FS
FS
Part No.
Screen type
Weight kg/km
O/D mm
Protocol
2202PIFRL
8723
2
22
Individual foils
32
4.2
Traditional security
2202PIFRH
8723NH
2
22
Individual foils
32
4.2
Traditional security
2203PIFRL
8777
3
22
Individual foils
32
7.0
Traditional security
2203PIFRH
8777NH
3
22
Individual foils
32
7.0
Traditional security
2402POHPL
9842
2
24
O/A foil & braid
95
8.6
RS-485
2402POHPH 9842NH
2
24
O/A foil & braid
95
8.6
RS-485
2802PODGH 8132NH
2
28
O/A foil & braid
45
5.6
RS-485
2803PODGH 8133NH
3
28
O/A foil & braid
52
6.8
RS-485
cables
cables
FS
FS cables
Access control and door release cables are also available from stock in PVC versions either in standard pack sizes or cut to length from bulk drums.
Low Smoke Halogen Free
www.fscables.com
sales@fscables.com
57
Composite Coaxial & Door Entry FIRE & SECURITY Composite Coaxial & Door Entry To meet the increasing demands for camera cables containing a coax with power and control cores for Pan, Tilt, Zoom (PTZ) or audio we are now stocking at a variety of options. These can either be within one circular jacket for easy glanding or in a shotgun style with a web between the individual elements for branching off at termination points.
3900592/2
Designed to meet the need of the installer of proprietary door entry systems, door entry cables cover video, voice and door release. Stocked on bulk drums, cutting to length is offered to reduce your wastage and cut costs. Armoured and Duct grade versions are also available. Composite Coaxial Part No.
Coax
Power Cores
Signal Cores
Construction
O/D mm
Colour
3900592/2
RG59 B/U
2 x 1.5mm²
2 x 0.22mm²
Circular
10.8
Black
3900592/2D
RG59 B/U
2 x 1.5mm²
2 x 0.22mm²
Circular Duct
13.4
Black
3900592/2H
Black
RG59 B/U
2 x 1.5mm²
2 x 0.22mm²
Circular LSHF
10.8
390059/2
RG59
2 x 0.75mm²
-
Shotgun
12.7 x 6.2
Black
390059/2D
RG59
2 x 0.75mm²
-
Circular Duct
10.3
Black
Shotgun
12.2 x 6.2
Black
Shotgun LSHF 12.2 x 6.2
Black
390059-Shotgun 2 x RG59
-
-
390059H-Shotgun 2 x RG59
-
-
2 x 0.75mm²
-
391070/2
URM70
Shotgun
10.2 x 5.8
White
Door Entry Part No.
Coax
Power Cores
Signal Cores
Construction
O/D mm
Colour
DE12C
7/0.15mm 75 Ω 1 x 1.5mm² + 6 x 1mm²
5 x 0.5mm²
PVC
12.5
Grey
DE5C
7/0.15mm 75 Ω
3 x 0.5mm²
PVC
9.2
White
2 x 1mm²
DE12C
Other constructions are available on short lead-times please call us with your specific requirements.
FS
Alt. to Belden
No. of Pairs
AWG
Screen type
Weight kg/km
O/D mm
Protocol
1601PUYL
8471
1
16
Unscreened
56
7.0
Echelon
1601PUYH
8471NH
1
16
Unscreened
56
7.0
Echelon
FS
cables
FS
FS
FS
FS
FS
Duct Grade
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Low Smoke Halogen Free
FS
cables
Part No.
cables
Bus Wiring & Door Release
cables
58
FIRE & SECURITY Alarm Cables
Alarm Cables Designed for inter-connecting sensors and control panels, alarm cables are widely used within the security industry. Manufactured in white or black as standard, although other colours can be easily and quickly produced for quantities as low as 300m, for example to identify a circuit or blend with a colour scheme. Cables held in stock include standard PVC, Low Smoke Halogen Free, screened and duct grade versions. Technical Information Temperature Rating: Conductor Size:
Max Working Voltage: 50V Max Current: 1 amp per core
0째C to +70째C 0.22mm2 (24AWG)
Construction
39800208W
PVC:
Tinned copper wire strands, PVC insulation, PVC sheath
LSHF:
Tinned copper wire strands, Low Smoke Halogen Free insulation, Low Smoke Halogen Free sheath (with or without aluminium foil screen)
Screened: Tinned copper wire strands, PVC insulation, aluminium foil screen with tinned copper drain wire, PVC sheath Duct:
Tinned copper wire strands, PVC insulation, PVC inner sheath, black LDPE outer sheath
Unscreened Alarm Part No.
Screened Alarm
Cores
Weight kg/km
O/D mm
cables
cables
cables
FS
18
3.4
39900204W
4
24
3.7
39800206W
6
25
4.0
39900206W
6
28
4.3
39800208W
8
30
4.3
39900208W
8
34
4.6
39800212W
12
37
5.5
39900212W
12
47
6.2
Part No.
Cores
Weight kg/km
O/D mm
Weight kg/km
O/D mm
Part No.
Cores
LSHF Foil Screened Alarm Cable
39800204WH
4
18
3.4
39900204WH
4
24
3.7
39800206WH
6
25
4.0
39900206WH
6
28
4.3
39800208WH
8
30
4.3
39900208WH
8
34
4.6
39800212WH
12
42
5.7
Cores
Weight kg/km
O/D mm
Cores
Weight kg/km
O/D mm
Part No.
Duct Grade Screened Alarm Cable
Duct Grade Unscreened Alarm Cable
39200206D
6
52
6.8
39400206D
6
53
7.1
39200208D
8
56
7.1
39400208D
8
58
7.6
39200212D
12
68
8.4
39400212D
12
72
9.0
Core Colour Code 4-core: Red, blue, yellow, black 6-core: Red, blue, yellow, black, white, green 8-core: Red, blue, yellow, black, white, green, orange*, brown 12-core: Red, blue, yellow, black, white, green, orange, brown, grey, pink, violet, turquoise *On duct grade cables core 7 is violet. Brown or black PVC alarm cable also available. Standard packing 100m, 200m & 500m spools.
FS cables
O/D mm
4
Part No.
FS
Weight kg/km
39800204W
LSHF Unscreened Alarm Cable
FS
Cores
PVC Foil Screened Alarm Cable
PVC Unscreened Alarm Cable
39900208WH
Part No.
Low Smoke Halogen Free
Duct Grade
www.fscables.com
sales@fscables.com
59
Outdoor Control FIRE & SECURITY Outdoor Control The FSC range of duct grade YY cable is suitable to be either run through ducts or clipped to buildings or other exposed areas when an armoured cable is not required. The cables are rated to 0.6/1kV and have XLPE insulation, a PVC bedding and a UV stable black polyethylene sheath which also gives additional mechanical strength and water resistance. The colour code is the conventional brown, blue, green/yellow (on three core) for simple wiring. Despite their toughness they remain remarkably flexible.
10001504D
The cable is stocked on bulk drums and can be cut to length to reduce your wastage and save time. If you don’t see the size you require please call us because we offer a cable over-sheathing service. If these cables require added protection we can also armour them with MOQs as low as a hundred metres. Please see page 152-153 for more details or call us with your specific requirements. Despite their toughness they remain remarkably flexible. They can also be used as an alternative to the old Delta Hi-Tuf cables.
Construction
Technical Information
Plain copper wire conductors to IEC 60228 class 5, XLPE colour coded insulation, bedding compound of PVC, UV resistant polyethylene sheath.
Voltage Rating: Conductor Stranding: Temperature Rating: Bending Radius:
0.6/1kV Stranded. IEC 60228 class 5 -30°c to +90°c 10 x overall diameter
For other cables suitable for outdoor applications please see page 60-61 for more details
Part No.
Cores x mm2
Colour Code
Weight kg/km
O/D mm
9.1
2 x 1.0
Blue, Brown
78
10001003D
3 x 1.0
Blue, Brown, Green/Yellow
98
9.2
10001004D
4 x 1.0
Brown, Black, Grey, Green/Yellow
121
9.6
10001005D
5 x 1.0
Blue, Brown, Black, Grey, Green/Yellow
149
10.7
10001502D
2 x 1.5
Blue, Brown
105
9.2
10001503D
3 x 1.5
Blue, Brown, Green/Yellow
156
10.5
10001504D
4 x 1.5
Brown, Black, Grey, Green/Yellow
181
11.4
10001505D
5 x 1.5
Blue, Brown, Black, Grey, Green/Yellow
201
12.3
2 x 2.5
Blue, Brown
154
11.0
3 x 2.5
Blue, Brown, Green/Yellow
183
11.0
10002504D
4 x 2.5
Brown, Black, Grey, Green/Yellow
241
13.1
10002505D
5 x 2.5
Blue, Brown, Black, Grey, Green/Yellow
304
14.2
cables
FS
10002502D 10002503D
FS
cables
FS
FS
FS
FS
FS
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Duct Grade
FS
cables
10001002D
cables
60
FIRE & SECURITY Outdoor Data & Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC Outdoor Data & Coaxial 60331)
2403POFYD
With the increased use of data and signal cables in security, BMS, access control and monitoring applications the need for suitable cables to run outside or through ducts has grown. FS Cables offer an over-sheathing service for any stock product for quantities as low as 100m. The products listed below are all stock items and have heavy additional black UV resistant polyethylene sheaths similar to those used on external telephone cables you see strung between poles or run though ducts.
Part No.
Alternative to Belden
Number of Pairs & AWG
Weight kg/km
O/D mm
Colour
Outdoor Data Cables 1801POFPD
8760
1 x 2 x 18
48
7.6
Black
2202PIFRD
8723
2 x 2 x 22
50
6.2
Black
2203PIFRD
8777
3 x 2 x 22
96
8.6
Black
2401POFYD
9501
1 x 2 x 24
44
6.2
Black
2403POFYD
9503
3 x 2 x 24
66
8.1
Black
2404POFYD
9504
4 x 2 x 24
72
8.9
Black
2406POFYD
9506
6 x 2 x 24
93
9.6
Black
2402PIFFD
9729
2 x 2 x 24
79
10.2
Black
2402POHPD
9842
2 x 2 x 24
118
10.6
Black
Part No.
Description
Number of Pairs & AWG
Weight kg/km
O/D mm
Colour
Exterior Grade Structured Wiring C5ED
C5ED
Cat 5E UTP Duct Grade
4 x 2 x 24
67
8.6
Black
C5EFD
Cat 5E FTP Duct Grade
4 x 2 x 24
68
8.8
Black
C525D
Cat 5 UTP Duct Grade
25 x 2 x 24
278
17.0
Black
C6D
Cat 6 UTP Duct Grade
4 x 2 x 23
86
9.9
Black
C6FD
Cat 6 FTP Duct Grade
4 x 2 x 23
105
10.2
Black
Part No. cables
FS
FS cables
Description
Weight kg/km
O/D mm
Colour
Black
Outdoor Coaxial Cables 390011D
RG11 A/U Duct Grade
194
12.1
390058D
RG58 C/U Duct Grade
59
6.5
Black
390059D
RG59 B/U Duct Grade
70
8.0
Black
391070D
URM 70 Duct Grade
67
7.8
Black
392100D
TV 100 Duct Grade
30
7.0
Black
392125D
TV 125 Duct Grade
52
9.5
Black
392167D
TV 167 Duct Grade
110
11.7
Black
cables
FS
FS cables
Duct Grade
www.fscables.com
sales@fscables.com
61
Armoured Data & Coaxial FIRE & SECURITY N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC Armoured Data & Coaxial 60331) Where data or signal cables may be exposed to mechanical damage an additional protection of galvanised steel wire armour or SWA is ideal. Suitable for direct burial these cables are also popular in applications above ground where accidental or deliberate damage may occur.
390059A
CCTV installation in football stadiums, shopping centres and other public areas need to continue functioning despite the activities of trouble makers. Equally important may be data or security cabling in car parks, warehouses and factories where vehicle damage may severely compromise the operation of business.
Part No.
Alternative to Belden
Number of Pairs & AWG
Weight kg/km
O/D mm
Colour
2202PIFRA
8723
2 x 2 x 22AWG
200
10.0
Black
2203PIFRA
8777
3 x 2 x 22AWG
330
13.3
Black
2402POHPA
9842
2 x 2 x 24AWG
431
16.3
Black
2402PIFFA
9729
2 x 2 x 24AWG
387
15.4
Black
Part No.
Description
Number of Pairs & AWG
Weight kg/km
O/D mm
Colour
Armoured Structured Wiring C5EA
Cat 5E UTP
4 x 2 x 24AWG
259
12.6
C525A
Cat 5E UTP
25 x 2 x 24AWG
540
20.2
Black
C5EFA
Cat 5E FTP
4 x 2 x 24AWG
271
13.0
Black
C6A
Cat 6 UTP
4 x 2 x 23AWG
354
14.3
Black
C6FA
Cat 6 FTP
4 x 2 x 23AWG
386
15.1
Black
Part No.
Description
Weight kg/km
O/D mm
Black
Colour
Armoured Coaxial Cables 390011A
RG11 A/U
367
14.4
Black
390059A
RG59 B/U
235
10.5
Black
390062A
RG62 A/U
214
10.3
Black
FS
cables
FS
FS
FS
FS
FS
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
SWA
cables
FS
cables
FS
cables
62
LONDON UNDERGROUND LU Approved Cables
London Underground Approved Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Designed to meet London Underground (LU) specification for fire performance this collection of cables is also popular on overground railways, other transport systems and other commercial applications where fire and smoke propagation are critical factors. Applications range from CCTV and radio communications to alarm and emergency evacuation circuits. Coaxial Cables Construction Solid plain copper conductor, foamed PE dielectric, copper foil screen, plain copper wire braid, LSHF inner sheath.
390H124HLU
Part No.
390H124HLU
London Underground Standard E4156.1-A3 & E4156.2-A4 Section 12 Approved LSHF Sheath Material to HD 624
Description
Imp. Ohms
Central Cond.
H124 LSHF UV Resistant
75
1/1.00
Dielectric
Sheath Weight kg/km
FPE
O/D mm
LSHF
53
7.0
Triaxial Cables Construction
London Underground Standard
Solid plain copper conductor, foamed PE dielectric, copper foil screen, plain copper wire braid, LSHF inner sheath.
E4156.1-A3 & E4156.2-A4 Section 12 Approved LSHF Sheath Material to HD 624
Part No.
390H124HTLU
Description
Imp. Ohms
Central Cond.
Dielectric
Sheath
Weight kg/km
O/D mm
H124 LSHF UV Resistant
75
1/1.00
FPE
LSHF
99
8.8
Cat 5E FTP LSZH Construction 24(1)AWG solid plain copper conductor, polyolefin insulation, tinned copper drain wire in contact with overall aluminium foil screen, flame retardant LSHF grey sheath. This cable meets the London Underground Code of Practice for Fire Safety of Materials used in the Underground. Part No.
Description
Weight kg/km
O/D mm
Packed
Colour
Cat 5E FTP LSHF
40
6.5
On reels
Grey
64904002 C5EFHRLU cables
FS
Single Core LSHF Construction Class 2 plain copper conductor, single or double layer of LSHF insulation.
FS cables
cables
FS
Part No.
649010xx 649015xx 649025xx 649040xx 649060xx 649100xx 649160xx 649250xx 649350xx
Technical Information Temperature Rating: 90°C Voltage Rating: 450/750V AC Fire Test & Smoke Emission: 1.0-10mm² to LUL 1-085 16 – 35mm² to LUL 2-01001-002 Toxicity: To LUL 1-085
Size mm2
1.0 1.5 2.5 4.0 6.0 10 16 25 35
Insulation Layer
Weight kg/km
O/D mm
Double Double Double Double Double Double Single Single Single
35 40 55 75 100 150 190 300 390
4.7 2.0 5.3 6.0 6.6 7.8 7.6 9.6 10.8
*please see page 91 for colour chart
FS cables
www.fscables.com
sales@fscables.com
63
LU Approved Cables LONDON UNDERGROUND Fire Alarm Cable - Standard Construction
Standards
Solid plain copper conductor, silicone rubber, metallic barrier, tinned copper earth conductor, Low Smoke Halogen Free sheath.
BS5839-1:2002 Clause 26.2d standard BS EN 50200 PH30, PH 60 Annexe E. BS 6387 C, W & Z IEC 60331-2, IEC 60332-3, IEC 60332-1, BS EN 50265, BE EN50266, IEC 60754, BS EN 50267, IEC 61034, BS EN 50268
Cores x mm2
Part No.
Colour
Weight kg/km
387E01504FTER
O/D mm
38701502FTER
2 x 1.5
Red
100
7.7
38701502FTEW
2 x 1.5
White
100
7.7
38701504FTER
4 x 1.5
Red
145
9.2
38701504FTEW
4 x 1.5
White
145
9.2
38702502FTER
2 x 2.5
Red
150
8.9
38702502FTEW
2 x 2.5
White
150
8.9
38702504FTER
4 x 2.5
Red
220
10.9
38702504FTEW
4 x 2.5
White
220
10.9
Fire Alarm Cable - Enhanced Construction
Standards
Solid plain copper conductor, enhanced silicone rubber, glass tape, tinned copper earth conductor, metallic barrier, enhanced Low Smoke Halogen Free sheath.
BS5839-1:2002 Clause 26.2e enhanced BS8434-2:2003 BS EN 50200 PH120 BS 6387 C, W & Z IEC 60332-3, IEC 60332-1, BS EN 50265, BE EN50266, IEC 60754, BS EN 50267, IEC 61034, BS EN 50268
Cores x mm2
Part No.
O/D mm
Red White Red White Red White Red White
130 130 170 170 175 175 250 250
8.6 8.6 10.1 10.1 9.9 9.9 11.9 11.9
Firetuf Data & Coax
FS
FS
FS
FS
cables
For full technical details please see page 55 FSC Part No.
387FTD403
Type
Screen
Sheath
Weight kg/km
O/D mm
387FTD103
910234
Foil & Braid
LSHF red
48
6.8
387FTD203
910244
Foil & Braid
LSHF red
97
387FTD403 387FTD5903
910245 660096
1 Pair 0.63mm [22(1)AWG] 2 Pair 0.63mm [22(1)AWG] 4 Pair 0.63mm 75ohm coax 1/0.65mm
Foil & Braid Double braid
LSHF red LSHF red
122 110
Fax : 01727 840 842
8.1
cables
Tel: 01727 840 841
FS
cables
FS
cables
Draka Part No.
cables
2 x 1.5 2 x 1.5 4 x 1.5 4 x 1.5 2 x 2.5 2 x 2.5 4 x 2.5 4 x 2.5
Weight kg/km
cables
387E01502FTER 387E01502FTEW 387E01504FTER 387E01504FTEW 387E02502FTER 387E02502FTEW 387E02504FTER 387E02504FTEW
Colour
10.4 9.1
FS
cables
FS cables
64
TELEPHONE CW1308 PVC
CW1308 PVC Internal N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Manufactured to British Telecom Specification CW1308, this cable is used for internal connection of telephone systems and Fire resistant screenedequipment. power cables provide EMI screening and circuit integrity in the event of a fire. They are ideal for other communications applications such as fire pumps and ventilation systems in office blocks where electrical interference needs keeping to a minimumand during normal services be maintained for evacuation fire situation. cables meet Insulated sheathed in operation PVC, theseand cables offermust an extremely cost effective generalduring signalacable for fixed The installation. IEC 60331 and are fireisresistant for 3 hours at sizes 750°C. Standard sheath colour white although some are available in black or grey. cablesspecification to DIN 4102 telephone part 12 arecables also available request. AE30 fullSystem range integrity of European is also on available on short lead times, please call us with your requirements. Construction
Technical Information
Solid copper conductor, colour coded PVC insulation,
Conductor Diameter:
0.5mm
twisted in pairs, rip cord, PVC sheath.
Max. Conductor Resistance:
97.8 Ohm/km 12.4 Ohm/km
Earth 1.38mm
Max. Capacitance Unbalanced: 500pF/km
Part No.
30810E
cables
FS
FS cables
cables
FS
FS cables
Temperature Rating:
Working
Min. Bend Radius Fixed:
8 x cable diameter
0°C to +70°C
No. of Pairs
Weight kg/km
O/D mm
30802
2
21
4.5
30803
3
28
5.0
30804
4
34
5.8
30806
6
44
6.8
30810
10
67
8.3
30810E
10+E
85
8.6
30815
15
115
9.8
30820
20
150
10.7
30820E
20+E
183
12.0
30825
25
184
11.4
30825E
25+E
210
12.0
30830
30
226
12.2
30830E
30+E
262
12.9
30840E
40+E
371
15.0
30850E
50+E
427
17.0
30880E
80+E
610
20.2
308100E
100+E
708
27.0
308160E
160+E
1059
30.3
308200E
200+E
1393
33.1
Other pair combinations or larger numbers of pairs and alternative conductor sizes are available on request. Cables ending with E include a 1.38mm Earth core. Colour codes to BT Standards, see page 166-167.
www.fscables.com
sales@fscables.com
65
CW1308 LSHF TELEPHONE CW1308 LSHF Internal
When you need a LSHF internal telephone cable but don’t want to go to the expense of CW1600 this range is ideal. Manufactured generally in accordance with BT CW1308 specification both the insulation and sheath materials have been changed to ones that don’t emit poisonous halogens in the event of a fire. These cables are not to be confused with the cheaper, PVC insulated, modified PVC jacketed LSF versions that have appeared on the market in the last few years. Construction
Technical Information
Solid copper conductor, colour coded Low Smoke
Conductor Diameter:
0.5mm
Halogen Free insulation, twisted into pairs, rip cord,
Max. Conductor Resistance:
97.8 Ohm/km 12.4 Ohm/km
Low Smoke Halogen Free jacket, white. Earth core
Max. Capacitance Unbalanced: 500pF/km
in cables with 10 pairs or more.
Temperature Rating:
Working
Min. Bend Radius Fixed:
8 x cable diameter
Part No.
No. of Pairs
Weight kg/km
O/D mm
30802H
2
22
4.5
30803H
3
31
5.0
30804H
4
34
5.8
30806H
6
50
6.8
30810EH
10+E
102
8.6
30820EH
20+E
161
12.0
30850EH
50+E
352
17.0
308100EH
100+E
687
27.0
Earth 1.38mm
0°C to +70°C
30850EH
FS
cables
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
FS
cables
FS
cables
66
TELEPHONE CW1600 LSHF
CW1600 LSHF Limited Fire Hazard Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: XLPE/Cu/LSHF LSHF Power Cable – 0.6/1kV This cable is similar in design and application to CW1308 but with the addition of an aluminium foil screen and Low Smoke Halogen Free cores and sheath. Used for the internal wiring of buildings where the need to protect people and equipment from smoke and fumes is paramount. CW1600 has the added advantage of an aluminium/polyester foil screen and drain wire. A fire barrier tape is included on cable with more than 6 pairs. A rip cord is located directly under the jacket to make stripping the outer sheath easier. Construction
Technical Information
Solid copper conductor, colour coded Low Smoke Halogen Free
Conductor Diameter:
0.5mm
insulation. Twisted into pairs, screened with an aluminium /
Max. Conductor Resistance:
97.8 Ohm/km 12.4 Ohm/km
polyester tape in contact with solid copper drain wire, fire barrier
Max. Capacitance Unbalanced: 500pF/km
tape on cables with more than 6 pairs, Low Smoke Halogen Free
Temperature Rating:
Working
sheath.
Minimum Bending Radius:
8 x cable diameter
Oxygen Index:
35%
HCl Emissions to:
BT M234
Part No.
60010E
cables
FS
Earth 1.38mm
0°C to +70°C
No. of Pairs
Weight kg/km
O/D mm
60003
3
35
6.0
60004
4
39
6.4
60006
6
66
6.8
60010E
10+E
102
8.6
60020E
20+E
167
12.0
60040E
40+E
295
15.0
60050E
50+E
358
20.0
600100E
100+E
692
26.0
Cables ending with E include a 1.38mm Earth core. Colour codes to BT Standards, see page 166-167. All sizes are normally available from stock. Armoured versions can be produced to order for quantities as low as 100m.
FS cables
cables
FS
FS cables
www.fscables.com
sales@fscables.com
67
Functional Earth & Drop Wire TELEPHONE CW1044 Functional Earth CW1044 is primarily intended to provide a connection to earth for internal telephone systems. It features a single core plain annealed copper conductor which is solid in 1.5mm2 and stranded in all other sizes. 16mm2 and above is stocked in Low Smoke Halogen Free versions only. The insulation is cream with black printing ‘Telecom Functional Earth’.
Part No.
Size mm²
Stranding
Weight kg/km
Nominal O/D mm
044015
1.5
1/1.38
24
3.3
044025
2.5
7/0.67
38
3.9
04404
4.0
7/0.85
57
4.6
04406
6.0
7/1.04
87
5.4
04410
10
7/1.35
110
6.1
04416H
16
7/1.70
172
7.1
04425H
25
7/2.14
285
8.9
04435H
35
7/2.52
380
10.1
04450H
50
19/1.78
510
11.8
04416H
CW1411 & CW1417 BT Drop Wire
37804
The FSC range of self supporting aerial cables is designed for use in local area networks to link between pole and building or two buildings. The high tensile steel strainer wires are incorporated within the cable. A black polyethylene sheath, which is UV stable offers excellent weather resistance. 2 pair Ref: CW1411 4 pair Ref: CW1417 No. of Pairs
37802
10B
2
37804
14 (55m)
4
Conductor Dia. mm
FS
FS
FS
cables
FS
FS
FS
FS
FS
Weight kg/km
Nominal O/D mm
0.5
32
5.3
0.5
35
5.6
Standard packing on Drop Wire is 350m reels.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Low Smoke Halogen Free
cables
BT Ref
cables
Part No.
cables
68
TELEPHONE CW1128
CW1128 External CW1128 external telephone cables are suitable for installation outdoors where an armoured cable is not necessary. They offer a lightweight, compact, tough solution for cables that will have to endure a variety of weather conditions, from rain and snow to bright sunlight. CW1128 is ideal for clipping around the outside of buildings or running through ducting. The outer sheath is made from tough, durable polyethylene which is also UV and sunlight resistant. The pairs are bedded in petroleum jelly to protect against the ingress of moisture.
Construction
Technical Information
Solid plain copper conductor, colour coded polyethylene
Conductor Diameter:
0.5mm
0.9mm
insulation, petroleum jelly filled, separator tape and a black
Max. Conductor Resistance:
91 Ohm/km
28 Ohm/km
polyethylene sheath.
Insulation Resistance:
1500 Mohm/km 1500 Mohm/km
Part No.
Capacitance Unbalanced: >3pair 275pF/m
275pF/m
Colour Code: see page 167
To CW1128
To CW1128
No. of Pairs
Conductor Dia. mm
Weight kg/km
O/D mm
12800502
2 (Quad)
0.5
50
5.9
12800503
3
0.5
58
6.6
12800505
5
0.5
76
8.0
12800510
10
0.5
113
9.5
12800520
20
0.5
184
12.0
12800530
30
0.5
249
13.0
12800550
50
0.5
381
16.5
128005100
100
0.5
710
22.0
Part No.
No. of Pairs
Conductor Dia. mm
Weight kg/km
O/D mm
12800520 Solid 0.5mm
cables
FS
FS cables
Solid 0.9mm 12800901Q
2 (Quad)
0.9
72
7.2
12800905
5
0.9
160
11.5
12800910
10
0.9
261
14.0
12800920
20
0.9
452
18.0
12800950
50
0.9
1076
26.5
128009100
100
0.9
2033
36.0
Aluminium screened/moisture barrier versions of this cable are also available in the style of CW1179 with some sizes from stock. Please call to check availability. cables
FS
FS cables
Duct Grade
www.fscables.com
sales@fscables.com
69
CW1128/1198 TELEPHONE CW1128/1198 Armoured
CW1128/1198 type telephone cables are used for external connection of telephone systems and other communications equipment where the added protection of steel wire armouring is needed. This cable is ideally suited for direct burial. The outer sheath is made from tough, durable polyethylene or external grade PVC which is UV and sunlight resistant. The cores are bedded in petroleum jelly to protect against the ingress of moisture. Construction
Technical Information
Solid plain copper conductor, colour coded
Conductor Diameter:
0.5mm
0.9mm
polyethylene insulation, petroleum jelly filled,
Max. Conductor Resistance:
91 Ohm/km
28 Ohm/km
separator tape, polyethylene bedding, galvanised
Insulation Resistance:
1500 Mohm/km 1500 Mohm/km
steel wire armour and a black or grey polyethylene or
Capacitance Unbalanced: >3pair 275pF/m
275pF/m
external grade PVC sheath.
Colour Code: see page 167
To CW1128
Part No.
No. of Pairs
Conductor Dia. mm
Weight kg/km
To CW1128
O/D mm
19800520
Solid 0.5mm 19800501Q
2 (Quad)
0.5
187
19800505
5
0.5
218
10.1 11.0
19800510
10
0.5
285
12.2
19800520
20
0.5
378
14.5
19800530
30
0.5
621
16.2
19800550
50
0.5
896
20.4
198005100
100
0.5
1368
26.2
Part No.
No. of Pairs
Conductor Dia. mm
Weight kg/km
O/D mm
2 (Quad)
0.9
320
12.8
19800905
5
0.9
496
13.9
19800910
10
0.9
738
17.4
19800920
20
0.9
1257
23.6
19800950
50
0.9
2310
32.3
198009100
100
0.9
3487
40.6 cables
FS
FS
FS
FS
FS
FS
FS
FS
cables
19800901Q
cables
Solid 0.9mm
cables
Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please call to check availability.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
SWA
cables
70
TELEPHONE J-Y(St)Y: PVC Screened
J-Y(St)Y: PVC Screened Telephone Cable Originally developed for use within offices and factories J-Y(St)Y meets the needs of the German telecom installers and increasingly their European counterparts. The larger conductor sizes result in lower losses than the traditional British CW1308. The foil screen also reduces interference either radiating from or picked up by the cable. Other applications include security, agriculture, intercom and bus systems.
Construction
Technical Information
Solid copper wire conductors to IEC 60228 class 1, PVC
Voltage Rating:
300V
insulation, overall foil screen in contact with solid copper
Conductor Stranding:
Solid IEC 60228 class 1
drain wire, PVC sheath – grey.
Temperature Rating:
Static -30°C to +70°C
Core Identification
Bending Radius:
Fixed 7.5 x overall diameter
Flame Retardant:
VDE 0472 test B,
Flexing -5°C to +50°C
Colour code according to DIN VDE 0815.
IEC 60332-1-2, EN 50265-2-1 Manufactured To:
VDE 0815
J-Y(St)Y can be also be supplied with a red outer jacket for identifying fire alarm systems that do not need to meet British building regulations, please put ‘03’ at the end of the part number to specify this cable. Also available unscreened as J-YY
31000602
cables
FS
FS cables
cables
FS
FS cables
Part No.
Pairs x mm
Weight kg/km
O/D mm
Part No.
31000602
2 x 2 x 0.6
45
5.0
31000802
31000603
3 x 2 x 0.6
55
6.4
31000803
31000604
4 x 2 x 0.6
65
6.6
31000605
5 x 2 x 0.6
75
31000606
6 x 2 x 0.6
85
Pairs x mm
Weight kg/km
O/D mm
2 x 2 x 0.8
65
7.0
3 x 2 x 0.8
85
8.6
31000804
4 x 2 x 0.8
105
9.1
7.3
31000805
5 x 2 x 0.8
125
9.6
7.5
31000806
6 x 2 x 0.8
150
11.2
31000608
8 x 2 x 0.6
95
8.0
31000808
8 x 2 x 0.8
180
11.7
31000610
10 x 2 x 0.6
115
10.1
31000810
10 x 2 x 0.8
225
13.3
31000612
12 x 2 x 0.6
130
10.4
31000812
12 x 2 x 0.8
255
14.0
31000616
16 x 2 x 0.6
155
11.0
31000816
16 x 2 x 0.8
320
16.1
31000620
20 x 2 x 0.6
200
12.1
31000820
20 x 2 x 0.8
385
17.0
31000624
24 x 2 x 0.6
225
13.2
31000824
24 x 2 x 0.8
470
19.1
31000630
30 x 2 x 0.6
285
14.0
31000830
30 x 2 x 0.8
570
20.9
31000640
40 x 2 x 0.6
355
15.1
31000840
40 x 2 x 0.8
715
23.2
31000650
50 x 2 x 0.6
440
17.3
31000850
50 x 2 x 0.8
900
26.2
31000660
60 x 2 x 0.6
510
19.2
31000860
60 x 2 x 0.8
1050
28.1
31000680
80 x 2 x 0.6
650
21.3
31000880
80 x 2 x 0.8
1450
31.6
310006100
100 x 2 x 0.6
850
24.0
310008100
100 x 2 x 0.8
1800
33.0
Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please call to check availability.
www.fscables.com
sales@fscables.com
71
J-H(St)H: LSHF Screened TELEPHONE J-H(St)H: LSHF Screened Telephone Cable
J-H(St)H was originally developed in Germany for internal wiring in sensitive areas. A number of things set this apart from the UK internal telephone cable CW1308. The major differences are it is LSHF throughout, screened, comes in 0.6mm or 0.8mm conductor size and has a completely different colour code. It is now finding popularity for wiring everything from intercom and nurse call systems right through to sophisticated security installations where the benefits of a screened LSHF low resistance cable make it an ideal choice.
Construction
Technical Information
Plain copper wire conductors to IEC 60228 class 1, LSHF
Voltage Rating:
300V
insulation, overall foil screen in contact with plain copper
Conductor Stranding:
Solid IEC 60228 class 1
drain wire, LSHF sheath – grey.
Temperature Rating:
Static -30°C to +70°C
Core Identification
Bending Radius:
Fixed 7.5 x overall diameter
Flame Retardant:
IEC 60332-3-24 Cat C
Halogen Emissions:
IEC 60754-2, BS EN 50267
Smoke Emissions:
IEC 61034-2, BS EN 50268
Flexing -5°C to +50°C
Colour code according to DIN VDE 0815.
J-H(St)H can be also be supplied with a red outer jacket for identifying permitted fire alarm systems, please put ‘03’ at the end of the part number to specify this cable.
Part No.
Pairs x mm
Weight kg/km
O/D mm
Part No.
Pairs x mm
Weight kg/km
O/D mm
31000602H
2 x 2 x 0.6
45
5.0
31000802H
2 x 2 x 0.8
65
7.0
31000603H
3 x 2 x 0.6
55
6.4
31000803H
3 x 2 x 0.8
85
8.6
31000604H
4 x 2 x 0.6
65
6.6
31000804H
4 x 2 x 0.8
105
9.1
31000605H
5 x 2 x 0.6
75
7.3
31000805H
5 x 2 x 0.8
125
9.6
31000606H
6 x 2 x 0.6
85
7.5
31000806H
6 x 2 x 0.8
150
11.2
31000602H
95
8.0
31000808H
8 x 2 x 0.8
180
11.7
10 x 2 x 0.6
115
10.1
31000810H
10 x 2 x 0.8
225
13.3
31000612H
12 x 2 x 0.6
130
10.4
31000812H
12 x 2 x 0.8
255
31000616H
16 x 2 x 0.6
155
11.0
31000816H
16 x 2 x 0.8
320
31000620H
20 x 2 x 0.6
200
12.1
31000820H
20 x 2 x 0.8
385
FS
31000624H
24 x 2 x 0.6
225
13.2
31000824H
24 x 2 x 0.8
470
19.1
31000630H
30 x 2 x 0.6
285
14.0
31000830H
30 x 2 x 0.8
570
20.9
31000640H
40 x 2 x 0.6
355
15.1
31000840H
40 x 2 x 0.8
715
31000650H
50 x 2 x 0.6
440
17.3
31000850H
50 x 2 x 0.8
900
31000660H
60 x 2 x 0.6
510
19.2
31000860H
60 x 2 x 0.8
1050
28.1
31000680H
80 x 2 x 0.6
650
21.3
31000880H
80 x 2 x 0.8
1450
31.6
310006100H 100 x 2 x 0.6
850
24.0
310008100H 100 x 2 x 0.8
1800
33.0
14.0 16.1 17.0
FS 23.2
26.2 cables
cables
FS
FS
FS
cables
cables
Fax : 01727 840 842
FS
FS
cables
Tel: 01727 840 841
FS
cables
8 x 2 x 0.6
31000610H
cables
31000608H
cables
72
SIGNAL & CONTROL YY PVC
YY PVC Multicore XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable ideal for use on portable or movable equipment or where flexibility will make installation considerably easier. A 600/1000V grade is now available in sizes above 0.75mm2 as are American UL listed versions. Where resistance to water or many oils is required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times.
Construction
Technical Information
Fine copper wire strands to IEC 60228 class 5 or class 6
Voltage Rating: Temperature Rating:
300/500V Test 3000V Static -20°C to +80°C Flexing -5°C to +70°C Minimum Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter
depending on cross section. PVC insulation with either number or colour coding. A green/yellow earth core is normally included in cables with more than 2 cores in 0.5mm2 and above. Cores twisted together, grey PVC sheath.
Part No.
10001507
Cores x mm²
Weight kg/km
YY Multicore Cable Number Coded 10000502 2 x 0.5 33 10000503 3 x 0.5 43 10000504 4 x 0.5 46 10000505 5 x 0.5 53 10000507 7 x 0.5 75 10000512 12 x 0.5 113 10000518 18 x 0.5 167 10000521 21 x 0.5 194 10000540 40 x 0.5 347
Current Rating:
O/D mm
4.9 5.2 5.7 6.4 6.6 8.9 10.7 11.7 15.5
Part No.
Cores x mm²
Weight kg/km
O/D mm
10001018 10001021 10001025 10001034 10001041 10001042 10001050 10001080
18 x 1.0 21 x 1.0 25 x 1.0 34 x 1.0 41 x 1.0 42 x 1.0 50 x 1.0 80 x 1.0
266 313 356 469 588 601 691 1099
12.4 14.2 14.7 16.6 18.3 18.5 19.9 24.6
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 10 x 1.5 12 x 1.5 14 x 1.5 18 x 1.5 21 x 1.5 25 x 1.5 32 x 1.5 34 x 1.5 42 x 1.5 50 x 1.5 61 x 1.5 65 x 1.5
64 80 99 112 150 212 250 289 362 426 515 634 671 836 973 1181 1359
6.2 6.6 7.3 7.9 8.9 11.2 11.7 12.8 13.9 15.5 17.2 18.7 19.3 20.4 22.6 25.2 26.8
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5
96 125 152 173 238 384 559
7.6 8.0 8.8 9.8 11.9 14.5 17.4
FS cables
10000702 10000703 10000704 10000705 10000707 10000708 10000710 10000712 10000718 10000721 10000725 10000734 10000741 10000742 10000750 10000761
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 8 x 0.75 10 x 0.75 12 x 0.75 18 x 0.75 21 x 0.75 25 x 0.75 34 x 0.75 41 x 0.75 42 x 0.75 50 x 0.75 61 x 0.75
41 54 58 69 97 109 133 151 216 263 296 392 466 496 585 693
5.2 5.7 6.1 6.7 7.2 8.6 9.3 9.9 11.5 13.8 14.1 15.9 16.9 17.6 19.3 20.9
10001502 10001503 10001504 10001505 10001507 10001510 10001512 10001514 10001518 10001521 10001525 10001532 10001534 10001542 10001550 10001561 10001565
FS
10001002 10001003 10001004 10001005 10001007 10001010 10001012
2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 10 x 1.0 12 x 1.0
50 60 63 81 126 157 183
5.5 5.9 6.6 7.1 7.6 9.9 10.5
10002502 10002503 10002504 10002505 10002507 10002512 10002518
cables
FS
cables
FS cables
Refer to IEE Regs Table 4F3A&B
Other core counts and sizes are available please ask for more details. Overall diameters (O/D) are approximate and for guidance only and will vary from one manufacture to another. If the O/D is critical please check at time of order and we will measure it.
www.fscables.com
sales@fscables.com
73
YY PVC SIGNAL & CONTROL Cores x mm²
Weight kg/km
O/D mm
Part No.
10001502C 10001503C 10001504E 10001505E 10001507C 10001512C
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5
64 80 99 112 150 250
6.2 6.6 7.3 7.9 8.9 11.7
10002502C 10002503C 10002504E 10002505E 10002507C 10002512C
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5
96 125 152 173 238 384
7.6 8.0 8.8 9.8 11.9 14.5
10004003C 10004004E 10004005E 10004007C
3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0
260 302 359 482
11.9 12.6 13.8 15.5
10006003C 10006004E 10006005E 10006007C
3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0
319 396 493 660
12.8 13.7 15.8 17.5
10010003C 10010004E 10010005E 10010007C
3 x 10 4 x 10 5 x 10 7 x 10
521 655 798 1063
16.1 17.7 19.8 21.8
10016003C 10016004E 10016005E
3 x 16 4 x 16 5 x 16
920 1095 1379
18.4 20.6 22.9
10025003C 10025004E 10025005E
3 x 25 4 x 25 5 x 25
1371 1592 2012
23.2 25.6 28.4
10035003C 10035004E 10035005E
3 x 35 4 x 35 5 x 35
cables
Part No.
1782 2151 2863
25.7 28.6 31.8
10050003C 10050004E 10050005E
3 x 50 4 x 50 5 x 50
2561 2983 3860
31.1 34.8 38.5
10070003C 10070004E 10070005E
3 x 70 4 x 70 5 x 70
10095003C 10095004E 10095005E
3 x 95 4 x 95 5 x 95
10120004E
4 x 120
10002521 10002525 10002534 10002550
21 x 2.5 25 x 2.5 34 x 2.5 50 x 2.5
737 793 1086 1579
21.5 22.1 23.8 28.9
10004003 10004004 10004005 10004007
3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0
182 235 276 358
9.7 10.6 11.8 13.0
10006003 10006004 10006005 10006007
3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0
273 337 407 498
11.9 12.8 14.3 16.7
10010004 10010005 10010007
4 x 10 5 x 10 7 x 10
532 675 894
15.8 17.9 19.5
10016004 10016005 10016007
4 x 16 5 x 16 7 x 16
849 1053 1389
19.2 21.7 23.8
10025004 10025005 10025007
4 x 25 5 x 25 7 x 25
1275 1580 2109
23.3 25.9 28.5
10035004 10035005
4 x 35 5 x 35
1686 2106
27.3 29.6
10050004
4 x 50
2534
32.1
10070004
4 x 70
3365
36.3
10095004
4 x 95
4535
41.4
10120004
4 x 120
5486
45.3
YY Multicore Cable Colour Coded 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75
41 54 58 69 97 151
5.2 5.7 6.1 6.7 7.2 9.9
10001002C 10001003C 10001004E 10001005E 10001007C 10001012C
2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0
50 60 63 81 126 183
5.5 5.9 6.6 7.1 7.6 10.5
Blue
Brown
3 core
Blue
Brown
Green/Yellow
Tel: 01727 840 841
4 core
Blue
Black
5 core
Blue
Brown
Grey Black
Fax : 01727 840 842
FS
3215 4123 4834 cables 4721 5583 6513
FS
7135
O/D mm
FS
FS
35.5 39.4 44.3cables 41.5 45.9 50.3
FS
52.3
cables
2 core
FS
cables
Colour Code:
Weight kg/km
cables
10000702C 10000703C 10000704E 10000705E 10000707C 10000712C
Cores x mm²
Green/Yellow Grey
Green/Yellow
FS
cables
FS cables
74
SIGNAL & CONTROL LiYY PVC Multicore
LiYY Miniature Signal Cable with DIN 47100 Fire Resistant (IEC 60331) N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, LSHF Power Cable – 0.6/1kV Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable ideal for use on portable or movable equipment or where flexibility will make installation considerably easier. A 600/1000V grade is now available in sizes above 0.75mm2 as are American UL listed versions. Where resistance to water or many oils is required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times. Construction
Technical Information
Fine copper wire strands to IEC 60228 class 5 or class 6
Voltage Rating:
depending on cross section. PVC insulation with DIN 47100 colour coding. Cores twisted together, grey PVC sheath.
0.14mm2 - 0.34mm2: Working 250V Test 1200V 0.5mm2 and above: Working 300/500V Test 3000V Temperature Rating: Static -20°C to +80°C Flexing -5°C to +70°C Minimum Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter Current Rating:
Part No.
30000325
cables
FS
FS cables
cables
FS
FS cables
Cores x mm²
Weight kg/km
O/D mm
LiYY Miniature Signal Cable with DIN 47100 Colour Code 30000102 2 x 0.14 12 3.3 30000103 3 x 0.14 15 3.5 30000104 4 x 0.14 17 3.7 30000105 5 x 0.14 22 4.0 30000107 7 x 0.14 26 4.7 30000112 12 x 0.14 43 5.7 30000118 18 x 0.14 65 7.2 30000121 21 x 0.14 79 7.5 30000125 25 x 0.14 93 8.1 30000132 32 x 0.14 112 8.8 30000140 40 x 0.14 132 9.6 30000152 52 x 0.14 177 10.9 30000161 61 x 0.14 204 11.6 30000202 30000203 30000204 30000205 30000207 30000212 30000218 30000221 30000225 30000232 30000240 30000252 30000261
2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 7 x 0.25 12 x 0.25 18 x 0.25 21 x 0.25 25 x 0.25 32 x 0.25 40 x 0.25 52 x 0.25 61 x 0.25
25 29 31 38 48 75 110 128 146 186 207 258 324
3.7 3.9 4.2 4.6 5.3 7.1 8.2 8.5 9.8 10.7 11.5 12.8 13.9
Refer to IEE Regs Table 4F3A&B
Part No.
Cores x mm²
Weight kg/km
O/D mm
30000302
2 x 0.34
28
4.4
30000303
3 x 0.34
30
4.6
30000304
4 x 0.34
40
4.9
30000305
5 x 0.34
44
5.6
30000307
7 x 0.34
60
6.2
30000312
12 x 0.34
88
8.1
30000318
18 x 0.34
135
9.7
30000321
21 x 0.34
151
10.4
30000325
25 x 0.34
181
11.5
30000332
32 x 0.34
223
12.4
30000340
40 x 0.34
266
13.5
30000352
52 x 0.34
337
15.5
30000361
61 x 0.34
392
16.5
30000502
2 x 0.5
31
4.9
30000503
3 x 0.5
35
5.2
30000504
4 x 0.5
42
5.7
30000505
5 x 0.5
49
6.2
30000507
7 x 0.5
73
7.2
30000512
12 x 0.5
130
9.2
30000518
18 x 0.5
166
11.3
30000521
21 x 0.5
185
13.1
30000525
25 x 0.5
250
13.4
30000532
32 x 0.5
291
14.7
30000540
40 x 0.5
345
16.1
30000552
52 x 0.5
454
19.7
30000561
61 x 0.5
536
20.4
The cables above are colour coded to DIN 47100. This colour code can be found on page 80. Other core counts and sizes are available please ask for more details. Overall diameters (O/D) are approximate and for guidance only and will vary from one manufacture to another. If the O/D is critical please check at time of order and we will measure it.
www.fscables.com
sales@fscables.com
75
Niltox LF-318 LSHF SIGNAL & CONTROL Niltox® LF-318 LSHF Colour Coded Multicore Low Smoke Halogen Free compounds are used to produce this high quality flexible cable that meets the requirements of 318* B and HO5ZZ-F. Niltox LF-318 is ideal for applications where the cable will be visible. Examples include: lighting pendant drops, supply leads and general wiring in public areas.
3180150300
As an option these cables can be oversheathed in a wide variety of colours in Low Smoke Halogen Free compounds. This is particularly useful when quantities are small or cables are needed quickly.
Construction
Technical Information
Fine copper wire strands to IEC 60228 class
Voltage Rating:
5, halogen free insulation, colour coded to
Temperature Rating: Flexing +5°C to +70°C
300/500V
Test 3000V
Static -20°C to +90°C
BS 7671 HD 308 S2. White or black Low Bending Radius:
Smoke Halogen Free outer sheath.
Flexing 15 x cable diameter Static 7.5 x cable diameter
Current Rating:
Refer to IEE Regs Table 4F3A&B
Flame Retardant:
IEC 60332-1-2
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
Cores x mm²
Weight kg/km
O/D mm
Part No.
Cores x mm²
Weight kg/km
O/D mm
31800702xx
2 x 0.75
60
6.3
31802502xx
2 x 2.5
150
9.1
31800703xx
3 x 0.75
70
6.7
31802503xx
3 x 2.5
184
9.8
31800704xx
4 x 0.75
88
7.1
31802504xx
4 x 2.5
228
10.9
31800705xx
5 x 0.75
112
7.8
31802505xx
5 x 2.5
270
11.9
31801002xx
2 x 1.0
71
6.7
31804003xx
3x4
216
14.0
31801003xx
3 x 1.0
84
7.1
31804004xx
4x4
286
15.1
31801004xx
4 x 1.0
106
7.9
31804005xx
5x4
342
15.4
31801005xx
5 x 1.0
134
8.7
31801006xx
6 x 1.0
163
9.8
31806004xx
4x6
338
15.2
31806005xx
5x6
422
17.5
3180150404
2 x 1.5
97
7.7
31801503xx
3 x 1.5
120
8.3
31810004xx
4 x 10
690
22.1
31801504xx
4 x 1.5
152
9.4
31810005xx
5 x 10
884
24.9
31801505xx
5 x 1.5
183
10.4
31801506xx
6 x 1.5
201
10.1
cables
FS
31801502xx
FS
cables
Part No.
FS
cables
FS
FS
FS
FS
FS
cables
To show the colour required please replace xx in the part number with: 04
White
00
Black
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
76
SIGNAL & CONTROL Niltox® LF-319 LSHF
® LF-319 LSHF XLPE/Cu/LSHF Niltox Multicore N2XCH-FE180/E90: Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Developed to meet the need for Low Smoke Halogen Free control cables, the Niltox LF-319 range covers all the popular sizes. Applications include airports, hospitals, lift shafts, tunnels, heating and ventilating controls, in fact anywhere that conventional PVC YY cables were previously used. In addition to its LSHF properties this cable offers a high degree of flame retardance thereby reducing the risk of spreading fire. Stocked on bulk reels, Niltox LF-319 cables can be cut to the length you require. Construction
Technical Information
Fine copper wire strands to IEC 60228 class 5, Low Smoke
Voltage Rating: 300/500V Test 2000V Temperature Rating: Flexing +5ºC to +70ºC Static -20ºC to +90ºC Bending Radius: Flexing 15 x cable diameter Static 7.5 x cable diameter Current Rating: Refer to IEE Regs Table 4F3A&B Flame Retardant: IEC 60332-1-2, IEC 60332-3-24C, UL 1685 Smoke Emission: IEC 61034-2, UL 1685 Halogen Emission: IEC 60754-1 & 2
Halogen Free insulation, black cores with white number coding, a green/yellow earth core is included in cables with more than 2 cores, grey Low Smoke Halogen Free outer sheath.
Part No.
Cores x mm²
Weight kg/km
O/D mm
31900703 31901507
31900704 31900705
cables
FS
FS cables
cables
FS
FS cables
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75
45 55 65 76
Cores x mm²
Weight kg/km
O/D mm
31901502
2 x 1.5
73
6.8
5.5
31901503
3 x 1.5
78
7.1
5.6
31901504
4 x 1.5
105
7.6
31901505
5 x 1.5
133
9.0
31901507
7 x 1.5
165
9.5
31901512
12 x 1.5
274
12.0
31901518
18 x 1.5
402
15.5
31901525
25 x 1.5
533
16.5
Number Coded 31900702
Part No.
6.5 7.3
31900707
7 x 0.75
93
7.5
31900712
12 x 0.75
140
9.1
31900718
18 x 0.75
240
12.5
31901534
34 x 1.5
850
19.9
31900725
25 x 0.75
343
14.3
31901550
50 x 1.5
1285
23.9
31900730
30 x 0.75
470
15.5
31901561
61 x 1.5
1475
25.4
31900734
34 x 0.75
225
16.5
31901565
65 x 1.5
1650
26.2
31900741
41 x 0.75
620
17.8
31900750
50 x 0.75
750
19.8
31902502
2 x 2.5
94
7.7
31902503
3 x 2.5
123
8.7
31902504
4 x 2.5
158
9.3
31902505
5 x 2.5
192
10.1
31902507
7 x 2.5
246
12.5
31902512
12 x 2.5
360
13.5
31902518
18 x 2.5
780
18.3
31902525
25 x 2.5
1050
22.1 9.3
31901002
2 x 1.0
49
6.0
31901003
3 x 1.0
59
6.5
31901004
4 x 1.0
75
6.7
31901005
5 x 1.0
88
7.5
31901007
7 x 1.0
112
8.0
31901012
12 x 1.0
170
10.2
31901018
18 x 1.0
252
12.0
31904002
2 x 4.0
172
31901025
25 x 1.0
363
15.0
31904003
3 x 4.0
185
9.9
31901034
34 x 1.0
685
17.6
31904004
4 x 4.0
198
10.1
31901041
41 x 1.0
790
18.8
31904005
5 x 4.0
270
12.5
21.2
31904007
7 x 4.0
475
13.5
31904012
12 x 4.0
800
18.5
31901050
50 x 1.0
870
Also available with a black sheath in some sizes. Other sizes are available on short lead times.
www.fscables.com
sales@fscables.com
77
Niltox® LF-319 LSHF SIGNAL & CONTROL Part No.
Cores x mm²
Weight kg/km
O/D mm
Part No.
Cores x mm²
Weight kg/km
O/D mm
31906002
2 x 6.0
243
10.9
Colour Coded
31906003
3 x 6.0
260
11.5
31906004
4 x 6.0
285
12.0
31901502C
2 x 1.5
73
6.8
31901503C
3 x 1.5
78
31906005
5 x 6.0
420
7.1
14.5
31901504E
4 x 1.5
105
31906007
7 x 6.0
7.6
640
16.2
31901505E
5 x 1.5
133
9.0
31910003 31910004
3 x 10
550
15.1
31902502C
2 x 2.5
94
7.7
4 x 10
710
16.9
31902503C
3 x 2.5
123
31910005
8.7
5 x 10
875
18.9
31902504E
4 x 2.5
158
9.3
31902505E
5 x 2.5
192
10.1
31904003C
3 x 4.0
185
10.0
31904004E
4 x 4.0
198
10.1
31904005E
5 x 4.0
270
12.5
31906003C
3 x 6.0
260
11.5
31906004E
4 x 6.0
285
12.0
31906005E
5 x 6.0
420
14.5
31910003C
3 x 10
550
15.1
31910004C
4 x 10
710
16.9
31910005C
5 x 10
875
18.9
31916003
3 x 16
850
17.8
31916004
4 x 16
1050
20.0
31916005
5 x 16
1300
22.2
31925003
3 x 25
1150
22.6
31925004
4 x 25
1600
25.5
31925005
5 x 25
2100
28.1
31935003
3 x 35
1600
25.5
31935004
4 x 35
2210
28.3
31935005
5 x 35
2700
31.3
31950003
3 x 50
2600
30.0
31916003C
3 x 16
850
17.8
31950004
4 x 50
3100
33.7
31916004C
4 x 16
1050
20.0
31950005
5 x 50
4000
37.4
31916005C
5 x 16
1300
22.2
31970003
3 x 70
3250
37.2
31925003C
3 x 25
1150
22.6
31970004
4 x 70
4100
41.4
31925004C
4 x 25
1600
25.5
31970005
5 x 70
5500
46.2
31925005C
5 x 25
2100
28.1
31995003
3 x 95
4750
41.5
31935003C
3 x 35
1600
25.5
31995004
4 x 95
5600
46.3
31935004C
4 x 35
31995005
5 x 95
7000
50.8
31935005C
5 x 35
FS
FS
FS
2210
28.3
2700
31.3
cables
cables
31912003
3 x 120
5600
46.0
31950003C
3 x 50
2600
30.0
31912004
4 x 120
7150
50.5
31950004C
4 x 50
3100
33.7
31950005C
5 x 50
4000
37.4
2 core
Blue
Brown
3 core
Blue
Brown
Green/Yellow
Tel: 01727 840 841
4 core
Blue
Black
5 core
Blue
Brown
Grey Black
Fax : 01727 840 842
FS
cables
cables
FS
Colour Code:
cables
cables
FS
Green/Yellow Grey
Green/Yellow
FS
cables
FS cables
78
SIGNAL & CONTROL LiYCY PVC
LiYCY PVC Screened Multicore LiYCY has a tinned copper wire braid screen, providing protection from electromagnetic interference (EMI) and reducing electromagnetic radiation (EMR). This can be important when trying to ensure electromagnetic compatibility (EMC). The braid screened LiYCY miniature signal and data cable range is available colour coded to DIN 47100. Larger core sizes over 0.5mm2 are also available number coded or colour coded. These cables are also available unscreened type LiYY with part numbers starting 300 please see page 74, or with the cores twisted into pairs and overall screens known as LiYCY-TP, part numbers starting 325 please see page 80-81; or twisted pairs without a screen LiYY-TP - part numbers starting 305. For Low Smoke Halogen Free types, please see the LF-315 & LF 329 range, pages 84 and pages 82-83 respectively.
Core Identification
Construction Fine copper wire strands to IEC 60228. PVC insulation
0.14mm2 - 0.34mm2. Colour Coded to DIN 47100.
colour or number coded. Cores twisted together with
Part numbers end in F.
overall polyester tape and tinned copper wire braid.
0.5mm2 - 35mm2. Black cores with white numbers + G/Y.
Grey PVC outer sheath.
Part numbers have no suffix. Technical Information Voltage Rating:
32001503C
Temperature Rating:
0.14mm2 - 0.34mm2:
Working 250V
Test 1000V
0.5mm2 - 1.5mm2:
Working 300V
Test 2000V
2.5mm2 - 6mm2:
Working 500V
Test 2000V
Static -20째C to +80째C
Flexing -5째C to +70째C
Minimum Bending Radius: Static 6 x cable diameter Conductor Stranding:
Part No.
Flexing 15 x cable diameter
Flexible to IEC 60228 Class 5 on 0.5mm2 and above.
Cores x mm2
Weight kg/km
O/D mm
Colour Coded to BS7671 HD 308 S2
cables
FS
FS cables
cables
FS
FS cables
32000702C 32000703C 32000704E 32000705E
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75
56 70 95 130
6.7 7.1 7.6 8.2
32001002C 32001003C 32001004E 32001005E
2x1 3x1 4x1 5x1
84 110 130 156
7.7 8.5 9.2 9.9
32001502C 32001503C 32001504E 32001505E
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5
97 125 165 193
8.1 8.9 9.7 10.5
32002502C 32002503C 32002504E 32002505E
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5
148 188 236 270
10.1 10.6 11.6 12.6
32004003C 32004004E 32004005E
3 x 4.0 4 x 4.0 5 x 4.0
250 302 370
12.4 13.5 14.8
www.fscables.com
sales@fscables.com
79
LiYCY PVC SIGNAL & CONTROL Part No.
Cores x mm²
Weight kg/km
O/D mm
17 30 37 44 51 55 60 77 93 104 115 132 137 173 184 190 198 212 238 260 290 333 382
3.7 4.5 5.1 5.2 5.7 6.1 6.4 7.1 8.1 8.4 8.7 8.9 9.4 10.4 11.4 11.5 11.6 11.9 12.7 13.1 14.3 14.9 15.8
32000302F 2 x 0.34 32000303F 3 x 0.34 32000304F 4 x 0.34 32000305F 5 x 0.34 32000306F 6 x 0.34 32000307F 7 x 0.34 32000308F 8 x 0.34 32000310F 10 x 0.34 32000312F 12 x 0.34 32000314F 14 x 0.34 32000316F 16 x 0.34 32000318F 18 x 0.34 32000321F 21 x 0.34 32000325F 25 x 0.34 32000327F 27 x 0.34 32000330F 30 x 0.34 32000336F 36 x 0.34 32000340F 40 x 0.34 32000352F 52 x 0.34 32000361F 61 x 0.34
33 42 49 59 64 69 84 106 119 132 146 188 193 213 232 253 292 318 400 454
32000502 2 x 0.5 32000503 3 x 0.5 32000504 4 x 0.5 32000507 7 x 0.5 32000512 12 x 0.5 32000518 18 x 0.5 32000525 25 x 0.5
42 5.4 51 5.8 61 6.5 98 7.8 156 10.1 215 11.8 314 14.4
32000702 32000703 32000704 32000705 32000707 32000712 32000718 32000725 32000730
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 30 x 0.75
56 70 95 130 168 232 315 418 500
6.7 7.1 7.6 8.2 8.9 12.0 13.9 16.5 18.0
32001002 32001003 32001004 32001005 32001007 32001012 32001018 32001025 32001034
2x1 3x1 4x1 5x1 7x1 12 x 1 18 x 1 25 x 1 34 x 1
84 110 130 156 192 265 380 475 629
7.7 8.5 9.2 9.9 10.7 13.7 15.9 17.5 21.5
Tel: 01727 840 841
5.0 5.4 5.8 6.1 6.6 6.7 7.4 8.5 8.7 9.1 9.6 10.1 10.9 12.0 12.3 12.7 13.6 14.0 15.8 16.6
Part No.
Cores x Weight mm² kg/km
O/D mm
32001502 32001503 32001504 32001505 32001507 32001512 32001518 32001525 32001530 32001542
2 x 1.5 97 3 x 1.5 125 4 x 1.5 165 5 x 1.5 193 7 x 1.5 245 12 x 1.5 365 18 x 1.5 553 25 x 1.5 720 30 x 1.5 776 42 x 1.5 1140
8.1 8.9 9.7 10.5 11.3 14.5 16.9 20.1 20.7 25.5
32002502 32002503 32002504 32002505 32002507 32002512 32002518
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5
148 188 236 270 340 585 725
10.1 10.6 11.6 12.6 13.7 18.5 19.7
32004003 32004004 32004005 32004007
3x4 4x4 5x4 7x4
250 302 370 473
12.4 13.5 14.8 16.1
32006003 32006004 32006005
3x6 4x6 5x6
285 13.9 412 15.2 505 16.7
32000325F
32010004 4 x 10 620 20.8 32010005 5 x 10 796 22.9 32016004 4 x 16 1090 23.2 32016005 5 x 16 2070 25.6
FS
32025004 4 x 25 1787 28.2 32025005 5 x 25 2047 31.1
FS
32035004 4 x 35 2142 31.5
Fax : 01727 840 842
FS
cables
FS
FS
FS
FS
FS
cables
cables
cables
32000201F 1 x 0.25 32000202F 2 x 0.25 32000203F 3 x 0.25 32000204F 4 x 0.25 32000205F 5 x 0.25 32000206F 6 x 0.25 32000207F 7 x 0.25 32000208F 8 x 0.25 32000210F 10 x 0.25 32000212F 12 x 0.25 32000214F 14 x 0.25 32000216F 16 x 0.25 32000218F 18 x 0.25 32000221F 21 x 0.25 32000224F 24 x 0.25 32000225F 25 x 0.25 32000227F 27 x 0.25 32000230F 30 x 0.25 32000236F 36 x 0.25 32000240F 40 x 0.25 32000244F 44 x 0.25 32000252F 52 x 0.25 32000261F 61 x 0.25
O/D mm
cables
3.6 3.8 4.0 4.3 4.6 5.0 5.2 5.6 6.3 6.4 6.7 7.2 7.6 8.3 9.0 9.0 9.1 9.4 10.0 10.3 11.1 11.5 12.1
Weight kg/km
cables
16 20 25 30 36 40 41 44 56 60 65 81 93 103 117 120 124 136 160 170 186 200 250
Cores x mm²
cables
32000101F 1 x 0.14 32000102F 2 x 0.14 32000103F 3 x 0.14 32000104F 4 x 0.14 32000105F 5 x 0.14 32000106F 6 x 0.14 32000107F 7 x 0.14 32000108F 8 x 0.14 32000110F 10 x 0.14 32000112F 12 x 0.14 32000114F 14 x 0.14 32000116F 16 x 0.14 32000118F 18 x 0.14 32000121F 21 x 0.14 32000124F 24 x 0.14 32000125F 25 x 0.14 32000127F 27 x 0.14 32000130F 30 x 0.14 32000136F 36 x 0.14 32000140F 40 x 0.14 32000144F 44 x 0.14 32000152F 52 x 0.14 32000161F 61 x 0.14
Part No.
cables
80
SIGNAL & CONTROL LiYCY TP PVC
LiYCY TP PVC Screened Paired Cables Popular as a European alternative to the American style data cables, LiYCY-TP has the cores twisted into pairs to reduce cross talk. The DIN 47100 colour code makes it easy to identify each conductor. The effects of electro magnetic interference (EMI) are also minimised by the use of an overall tinned copper wire braid screen. Used extensively for signal & data transmission where flexibility is important LiYCY-TP are designed for fixed or occasional movement although the cable construction make installation and routing through confined spaces simple.
Construction
Technical Information
Plain copper wire conductors to IEC 60228 class 5, PVC
Voltage Rating:
≤ 0.34mm² = 300V ≥ 0.5mm² = 300/500V
insulation, cores twisted in pairs, overall tinned copper wire braid, PVC sheath – Grey. LiHCH-TP which is an LSHF version is also available, please see page 85 for more details.
Conductor Stranding:
Stranded to IEC 60228 class 5
Temperature Rating:
Static -30°C to +80°C Flexing -5 to +70°C
Bending Radius:
Static 5 x overall diameter Flexing 10 x overall diameter
Flame Retardant:
VDE 0472 test B, IEC 60332-1-2, EN 50265-2-1
Manufactured To:
VDE 0814
Colour code:
DIN 47100
32500506F
DIN 47100 European Colour Codes The DIN 47100 standard specifies the core colour for up to 44 cores. Above this it is usual practice to repeat the colours. The first colour is the colour of the base insulation and the second colour is that of either a longitudinal stripe or printed rings.
cables
FS
FS cables
White
16
Yellow/Brown
31
Green/Blue
2
Brown
17
White/Grey
32
Yellow/Blue
3
Green
18
Grey/Brown
33
Green/Red
4
Yellow
19
White/Pink
34
Yellow/Red
5
Grey
20
Pink/Brown
35
Green/Black
6
Pink
21
White/Blue
36
Yellow/Black
7
Blue
22
Brown/Blue
37
Grey/Blue
8
Red
23
White/Red
38
Pink/Blue
9
Black
24
Brown/Red
39
Grey/Red
10
Violet
25
White/Black
40
Pink/Red
11
Grey/Pink
26
Brown/Black
41
Grey/Black
12
Red/Blue
27
Grey/Green
42
Pink/Black
13
White/Green
28
Yellow/Grey
43
Blue/Black
14
Brown/Green
29
Pink/Green
44
Red/Black
15
White/Yellow
30
Yellow/Pink
cables
FS
1
FS cables
www.fscables.com
sales@fscables.com
81
LiYCY TP PVC SIGNAL & CONTROL Part No.
Pairs x mm2
Weight kg/km
O/D mm
Part No.
Pairs x mm2
32500302F 32500303F 32500304F 32500305F 32500306F 32500307F 32500308F 32500310F 32500312F 32500314F 32500316F 32500318F 32500321F 32500325F 32500330F 32500334F 32500340F 32500344F 32500350F
2 x 2 x 0.34 3 x 2 x 0.34 4 x 2 x 0.34 5 x 2 x 0.34 6 x 2 x 0.34 7 x 2 x 0.34 8 x 2 x 0.34 10 x 2 x 0.34 12 x 2 x 0.34 14 x 2 x 0.34 16 x 2 x 0.34 18 x 2 x 0.34 21 x 2 x 0.34 25 x 2 x 0.34 30 x 2 x 0.34 34 x 2 x 0.34 40 x 2 x 0.34 44 x 2 x 0.34 50 x 2 x 0.34
65 87 115 121 139 149 165 232 239 248 267 296 308 410 451 525 623 648 714
7.1 7.8 8.5 9.4 9.9 10.1 10.9 12.2 13.3 13.6 14.6 15.7 16.3 18.1 19.2 20.3 21.6 22.4 23.8
32500502F 32500503F 32500504F 32500505F 32500506F 32500508F 32500510F 32500512F 32500516F 32500520F 32500525F 32500532F
2 x 2 x 0.50 3 x 2 x 0.50 4 x 2 x 0.50 5 x 2 x 0.50 6 x 2 x 0.50 8 x 2 x 0.50 10 x 2 x 0.50 12 x 2 x 0.50 16 x 2 x 0.50 20 x 2 x 0.50 25 x 2 x 0.50 32 x 2 x 0.50
102 135 159 168 210 268 315 355 475 532 623 810
7.8 8.4 9.5 9.9 11.3 12.2 13.6 14.4 16.8 18.5 20.2 22.5
32500702F 32500703F 32500704F 32500705F 32500706F 32500708F 32500710F 32500712F 32500716F 32500720F 32500725F
2 x 2 x 0.75 109 3 x 2 x 0.75 142 4 x 2 x 0.75 179 5 x 2 x 0.75 218 6 x 2 x 0.75 247 8 x 2 x 0.75 306 10 x 2 x 0.75 356 12 x 2 x 0.75 410 16 x 2 x 0.75cables 550 20 x 2 x 0.75 686 25 x 2 x 0.75 810
32500202F 32500203F 32500204F 32500205F 32500206F 32500207F 32500208F 32500210F 32500212F 32500214F 32500216F 32500218F 32500220F 32500224F 32500225F 32500226F 32500230F 32500232F 32500234F 32500236F 32500240F 32500244F 32500246F 32500250F
2 x 2 x 0.25 3 x 2 x 0.25 4 x 2 x 0.25 5 x 2 x 0.25 6 x 2 x 0.25 7 x 2 x 0.25 8 x 2 x 0.25 10 x 2 x 0.25 12 x 2 x 0.25 14 x 2 x 0.25 16 x 2 x 0.25 18 x 2 x 0.25 20 x 2 x 0.25 24 x 2 x 0.25 25 x 2 x 0.25 26 x 2 x 0.25 30 x 2 x 0.25 32 x 2 x 0.25 34 x 2 x 0.25 36 x 2 x 0.25 40 x 2 x 0.25 44 x 2 x 0.25 46 x 2 x 0.25 50 x 2 x 0.25
47 58 75 90 101 123 130 168 196 218 221 250 278 334 337 346 375 403 412 421 489 508 540 640
6.2 6.7 7.5 8.1 8.5 9.0 9.4 10.3 10.9 12.1 12.5 13.4 13.7 14.6 15.2 15.8 16.6 16.9 17.5 17.9 18.4 19.1 19.4 20.5
Tel: 01727 840 841
32501002F 32501003F 32501004F 32501502F 32501503F 32501504F
Fax : 01727 840 842
FS
FS
2 x 2 x 1.0 3 x 2 x 1.0 4 x 2 x 1.0 2 x 2 x 1.5 3 x 2 x 1.5 4 x 2 x 1.5
125 165 220 172 231 270
FS
8.5 9.4 10.2 11.6 12.2 13.5 15.2 16.5 19.0 cables 21.3 22.9
FS
FS
9.2 10.3 11.1 10.3 12.4 13.7
FS
FS
cables
FS
cables
5.4 6.0 6.5 7.2 7.6 7.7 8.2 9.0 9.5 10.1 10.6 11.3 11.6 12.5 12.9 13.1 13.5 13.6 14.6 14.7 15.5 16.2 16.5 17.5
O/D mm
cables
42 51 58 77 86 88 104 128 142 160 156 178 195 239 243 249 287 298 321 330 372 385 433 450
cables
2 x 2 x 0.14 3 x 2 x 0.14 4 x 2 x 0.14 5 x 2 x 0.14 6 x 2 x 0.14 7 x 2 x 0.14 8 x 2 x 0.14 10 x 2 x 0.14 12 x 2 x 0.14 14 x 2 x 0.14 16 x 2 x 0.14 18 x 2 x 0.14 20 x 2 x 0.14 24 x 2 x 0.14 25 x 2 x 0.14 26 x 2 x 0.14 30 x 2 x 0.14 32 x 2 x 0.14 34 x 2 x 0.14 36 x 2 x 0.14 40 x 2 x 0.14 44 x 2 x 0.14 46 x 2 x 0.14 50 x 2 x 0.14
cables
32500102F 32500103F 32500104F 32500105F 32500106F 32500107F 32500108F 32500110F 32500112F 32500114F 32500116F 32500118F 32500120F 32500124F 32500125F 32500126F 32500130F 32500132F 32500134F 32500136F 32500140F 32500144F 32500146F 32500150F
Weight kg/km
cables
82
SIGNAL & CONTROL Niltox® LF-329 LSHF
Niltox® LF-329 Dual Screened LSHF Multicore Niltox LF-329 is a Low Smoke Halogen Free alternative to the popular PVC LiYCY screened signal, control & power cable. Available from 0.75mm2 to 120mm2 these cables are LSHF throughout. Flexibility is excellent making installation easy. Core identification is straightforward with cores being clearly number coded and a green/yellow earth core included in cables with more than 2 cores. Applications include hospitals, airports, computer suites and control rooms, in fact anywhere where power or signals need to be protected from electromagnetic radiation or from corrupting other cables or equipment. The LSHF properties protect both people and equipment.
Construction
Technical Information
Fine copper wire strands to IEC 60228 class 5,
Voltage Rating:
Low Smoke Halogen Free insulation, cores twisted
Temperature Rating: Flexing +5°C to +70°C
300/500V
Static -20°C to +90°C
together, polyester tape, overall foil & tinned Bending Radius:
copper wire braid, grey Low Smoke Halogen Free
Flexing 10 x cable diameter Static 7.5 x cable diameter
sheath. Cores are black with white numbers, a green/yellow earth core is included in cables with more than 2 cores.
Part No.
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-24C, UL 1685
Smoke Emission:
IEC 61034-2, UL 1685
Halogen Emission:
IEC 60754-1 & 2
Cores x mm²
Weight kg/km
O/D mm
Cores x mm²
Weight kg/km
O/D mm
32900702
2 x 0.75
56
6.5
32902502
2 x 2.5
123
8.3
32902503
3 x 2.5
132
32900703
3 x 0.75
54
9.2
6.0
32902504
4 x 2.5
152
32900704
4 x 0.75
74
9.5
6.5
32902505
5 x 2.5
215
10.9
32900705
5 x 0.75
83
7.6
32900707
7 x 0.75
106
8.1
32902507
7 x 2.5
250
12.0
32902512
12 x 2.5
580
32900712
12 x 0.75
200
10.3
15.9
32900718
18 x 0.75
295
12.5
32900725
25 x 0.75
420
14.8
32904002
2 x 4.0
190
10.0
32904003
3 x 4.0
220
11.5
Number Coded 32900707
cables
FS
FS cables
cables
FS
FS cables
Test 2000V
Part No.
32901002
2 x 1.0
60
6.6
32904004
4 x 4.0
310
11.6
32901003
3 x 1.0
66
6.6
32904005
5 x 4.0
395
12.7
32901004
4 x 1.0
83
7.4
32904007
7 x 4.0
510
14.1
32901005
5 x 1.0
100
8.1
32901007
7 x 1.0
130
9.0
32906002
2 x 6.0
280
11.6
32901012
12 x 1.0
270
11.3
32906003
3 x 6.0
325
12.5
32901018
18 x 1.0
390
13.4
32906004
4 x 6.0
360
13.6
32901025
25 x 1.0
545
15.9
32906005
5 x 6.0
520
15.9
32906007
7 x 6.0
675
16.7
32910003
3 x 10
450
15.5
9.1
32910004
4 x 10
790
17.4
5 x 10
620
18.0
32901502
2 x 1.5
32901503 32901504 32901505
72
7.1
3 x 1.5
97
8.1
4 x 1.5
114
8.6
5 x 1.5
135
32901507
7 x 1.5
176
9.7
32910005
32901512
12 x 1.5
300
12.7
32916003
3 x 16
690
19.0
32901518
18 x 1.5
500
14.8
32916004
4 x 16
1300
22.7
32901525
25 x 1.5
710
17.8
32916005
5 x 16
2200
25.3
www.fscables.com
sales@fscables.com
83
Niltox® LF-329 LSHF SIGNAL & CONTROL Part No.
Cores x mm²
Weight kg/km
O/D mm
32925003
3 x 25
1450
23.3
Colour Coded
32925004
4 x 25
1950
26.4
32901502C
2 x 1.5
72
7.1
32901503C
3 x 1.5
97
8.1
32901504C
4 x 1.5
114
8.6
32901505C
5 x 1.5
135
9.1
32925005
5 x 25
2450
Part No.
29.5
Cores x mm²
Weight kg/km
O/D mm
32935003
3 x 35
2000
25.9
32935004
4 x 35
2575
30.5
32902502C
2 x 2.5
123
8.3
32935005
5 x 35
3200
34.0
32902503C
3 x 2.5
132
9.2
32902504C
4 x 2.5
152
9.5
32902505C
5 x 2.5
215
10.9
32904003C
3 x 4.0
220
11.5
32904004E
4 x 4.0
310
11.6
32904005E
5 x 4.0
395
12.7
32950003
3 x 50
3100
30.2
32950004
4 x 50
3600
34.8
32950005
5 x 50
4800
40.0
32970003
3 x 70
3900
37.8
32970004
4 x 70
5000
41.4
32906003C
3 x 6.0
325
12.5
32970005
5 x 70
6600
46.3
32906004E
4 x 6.0
360
13.6
32906005E
5 x 6.0
520
15.9
32910003C
3 x 10
450
15.5
32910004E
4 x 10
790
17.9
620
18.0
32995003
3 x 95
5700
41.3
32995004
4 x 95
6700
46.4
32995005
5 x 95
8400
51.5
32910005E
5 x 10
32912003
3 x 120
6400
46.7
32916003C
3 x 16
690
19.0
32916004E
4 x 16
1300
22.7
32916005E
5 x 16
32925003C
3 x 25
32925004E 32925005E
32935003C
3 x 35
32935004E 32935005E
32912004
4 x 120
8500
51.2
23.3
4 x 25
1950
26.4
5 x 25
2450
29.5
2000 cables
25.9
4 x 35
2575
30.5
5 x 35
3200
34.0
Blue
Brown
Green/Yellow
Tel: 01727 840 841
Blue
Black
5 core
Blue
Brown
Grey
FS
Black
Fax : 01727 840 842
Green/Yellow Grey
FS cables
FS
cables
3 core
4 core
cables
Brown
FS
cables
1450
cables
Blue
FS
25.3
Colour Code: 2 core
FS
2200
Green/Yellow
FS
cables
FS cables
84
SIGNAL & CONTROL Niltox® LF-315 LSHF
Niltox® LF-315 Screened LSHF Multicore Developed for signal and control applications in sensitive areas, the Niltox LF-315 range offers excellent flame retardance while emitting no halogens or other corrosive gases when exposed to fire. These cables are colour coded to the DIN 47100 standard and offer excellent flexibility and durability. Construction
Technical Information
Fine copper wire strands to IEC 60228. Low Smoke
Voltage Rating:
0.14mm2:
Halogen Free insulation, colour coded cores twisted
300V
together with overall PETP tape and tinned copper wire
0.25mm2 to 1.5mm2:
Test 800V
300/500V
braid. Flame retardant halogen free light grey sheath. Temperature Rating:
Test 1200V
Flexing -5°C to +70°C Static -40°C to +80°C
Bending Radius:
Flexing 15 x cable diameter Static 7.5 x cable diameter
31500712
cables
FS
FS cables
cables
FS
Flame Retardant:
IEC 60332-1-2
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
Colour Code:
DIN 47100 see page 80.
Part No.
Cores x mm²
Weight kg/km
O/D mm
Part No.
Cores x mm²
Weight kg/km
O/D mm
31500102
2 x 0.14
18
3.9
31500502
2 x 0.5
42
5.3
31500103
3 x 0.14
22
4.1
31500503
3 x 0.5
49
5.6
31500104
4 x 0.14
24
4.3
31500504
4 x 0.5
64
6.2
31500105
5 x 0.14
29
4.7
31500505
5 x 0.5
79
6.9
31500107
7 x 0.14
32
5.2
31500507
7 x 0.5
99
7.4
31500110
10 x 0.14
46
6.5
31500512
12 x 0.5
142
9.8
31500112
12 x 0.14
53
6.9
31500118
18 x 0.14
72
7.8
31500702
2 x 0.75
49
5.9
31500703
3 x 0.75
64
6.4
31500202
2 x 0.25
21
4.3
31500704
4 x 0.75
81
7.1
31500203
3 x 0.25
23
4.4
31500705
5 x 0.75
106
7.7
31500204
4 x 0.25
27
4.7
31500707
7 x 0.75
122
8.7
31500205
5 x 0.25
34
5.3
31500712
12 x 0.75
187
11.0
31500207
7 x 0.25
41
5.7
31500210
10 x 0.25
55
7.3
31501002
2 x 1.0
61
6.1
31500212
12 x 0.25
64
7.5
31501003
3 x 1.0
82
6.8
31500218
18 x 0.25
89
9.0
31501004
4 x 1.0
102
7.2
31501005
5 x 1.0
119
8.4
31500302
2 x 0.34
25
5.0
31501007
7 x 1.0
149
9.1
31500303
3 x 0.34
30
5.2
31500304
4 x 0.34
36
5.6
31501502
2 x 1.5
76
7.1
31500305
5 x 0.34
44
6.3
31501503
3 x 1.5
104
7.9
31500307
7 x 0.34
54
6.9
31501504
4 x 1.5
117
8.4
31500310
10 x 0.34
76
8.9
31501505
5 x 1.5
149
9.3
31500312
12 x 0.34
86
9.1
31501507
7 x 1.5
188
10.4
Other sizes and numbers of cores are often available on short delivery times, please ask for details.
FS cables
www.fscables.com
sales@fscables.com
85
Niltox® LF-316 LSHF SIGNAL & CONTROL ® LF-316 Screened Niltox LSHF Multipair N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
The Niltox LF-316 paired and screened range of Low Smoke Halogen Free data cables offer excellent flexibility and durability. Identification of the cores is made easy due to the DIN 47100 colour code. The cable is screened with an overall tinned copper wire braid offering excellent protection from electromagnetic interference. Construction
Technical Information
Fine copper wire strands to IEC 60228. Low Smoke
Voltage Rating:
0.14mm2:
Halogen Free insulation, colour coded, two cores
350V
twisted together to form a pair, pairs then twisted
0.25mm2 to 0.75mm2:
Test 800V
500V
together to form multipair cables, overall PETP tape and overall tinned copper wire braid. Flame retardant
Temperature Rating:
Test 1200V
Flexing +5°C to +70°C Static -40°C to +70°C
halogen free grey sheath. Bending Radius:
7.5 x cable diameter
Flame Retardant:
IEC 60332-1-2
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
Colour Code:
DIN 47100 see page 80.
Part No.
Pairs x mm2
Weight kg/km
O/D mm
Part No.
Pairs x mm2
Weight kg/km
O/D mm
31600102
2 x 2 x 0.14
36
5.3
31600501
1 x 2 x 0.5
42
31600103
3 x 2 x 0.14
47
6.2
31600502
2 x 2 x 0.5
76
7.6
31600104
4 x 2 x 0.14
65
7.4
31600503
3 x 2 x 0.5
108
8.9
31600106
6 x 2 x 0.14
86
8.1
31600504
4 x 2 x 0.5
135
10.3
31600505
5 x 2 x 0.5
152
11.5
31600506
6 x 2 x 0.5
168
11.7
31600507
7 x 2 x 0.5
186
11.9
31600512
12 x 2 x 0.5
331
16.0
5.5
7 x 2 x 0.14
94
8.7
31600112
12 x 2 x 0.14
134
10.7
31600201
1 x 2 x 0.25
21
4.5
31600202
2 x 2 x 0.25
44
5.9
31600203
3 x 2 x 0.25
65
7.1
31600204
4 x 2 x 0.25
80
8.0
31600702
2 x 2 x 0.75
106
9.1
3 x 2 x 0.75
138
10.0
6 x 2 x 0.25
114
9.0
31600207
7 x 2 x 0.25
121
9.4
31600704
4 x 2 x 0.75
165
11.6
31600212
12 x 2 x 0.25
173
11.0
31600705
5 x 2 x 0.75
234
13.5
31600707
7 x 2 x 0.75
259
13.8
31600712
12 x 2 x 0.75
439
18.4
31600302
2 x 2 x 0.34
67
7.3
31600303
3 x 2 x 0.34
91
8.5
31600304
4 x 2 x 0.34
109
9.5
31600306
6 x 2 x 0.34
140
10.0
31600307
7 x 2 x 0.34
155
11.0
31600312
12 x 2 x 0.34
246
14.5
cables
FS
31600206
31600703
FS
cables
31600107
31600506
cables
FS
FS
FS
FS
FS
cables
cables
cables
FS
Other sizes and pair counts are often available on short delivery times, please ask for details.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
86
SIGNAL & CONTROL RiserFlex 0.6/1kV RiserFlex 0.6/1kV Developed to meet the latest building requirements this Low Smoke Halogen Free cable is 0.6/1kV rated making it ideal to run in risers or under floors.
32801504E
The conductors are finely stranded to IEC60228 class 5 making installation simple and routing easy. Cores are colour coded to BS7671 in cables up to 5 cores. Above this they are black with white numbers. Cores are also rated at 0.6/1kV to comply with regulations for power cables in protected installations. Applications include wiring to computer systems, lift shafts, HVAC, security systems and BMS. Construction
Technical Information
Fine copper wire strands to IEC
Voltage Rating:
Working 0.6/1kV
60228 class 5, XLPE insulation, cores
Temperature Rating:
Static -20ºC to +80ºC
laid up. Low Smoke Halogen Free
Bending Radius:
Static 7.5 x cable diameter
sheath – black.
Flame Retardant:
IEC 60332-1-2
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
Oxygen Index:
>30% Up to 5 core in accordance with BS7671. Above 5 core, black numbered cores & G/Y earth
Core Identification:
Part No.
32802507
cables
FS
FS cables
Weight kg/km
O/D mm
32800702 32800703 32800704 32800705 32800707
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75
63 74 93 118 147
6.0 6.6 7.1 8.0 9.4
32801002
2x1
75
8.9
32801003
3x1
89
7.4
32801004
4x1
112
8.2
32801005 32801007
5x1 7x1
141 178
9.0 10.0
32801502 32801503
2 x 1.5 3 x 1.5
102 126
7.9 8.6
32801504
4 x 1.5
159
9.3
32801505
5 x 1.5
192
10.4
32801507 32801512
7 x 1.5 12 x 1.5
231 390
11.1 16.6
Part No.
Cores x mm²
Weight kg/km
O/D mm
32802502 32802503 32802504 32802505 32802507
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5
158 194 240 284 361
9.3 9.7 10.8 12.2 13.1
32804003 32804004 32806003 32806004
3x4 4x4 3x6 4x6
228 299 301 356
12.3 13.8 14.1 15.6
32810003 32810004
3 x 10 4 x 10
684 882
16.5 18.4
cables
FS
Cores x mm²
Test 3.5kV
FS cables
www.fscables.com
sales@fscables.com
87
RiserShield 0.6/1kV SIGNAL & CONTROL RiserShield 0.6/1kV RiserShield is a 0.6/1kV dual screened power, control and signal cable using Low Smoke Halogen Free materials throughout. Developed to run alongside power cables RiserShield is particularly popular for running clean supplies to computer equipment.
42601507
The double shield is effective at reducing both radiated and induced interference. The class 5 flexible conductors ensure the cable can be easily routed even through confined spaces.
Construction
Technical Information
Fine copper wire strands to IEC
Voltage Rating:
Working 0.6/1kV
60228 class 5, XLPE insulation, cores
Temperature Rating:
Static -40ºC to +80ºC
laid up, overall foil and tinned copper
Bending Radius:
Static 7.5 x cable diameter
braid. Low Smoke Halogen Free
Flame Retardant:
IEC 60332-1-2
sheath – black.
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
Oxygen Index:
>30% Up to 5 core in accordance with BS7671. Above 5 core, black numbered cores & G/Y earth
Core Identification:
Part No.
O/D mm
42600702
2 x 0.75
105
7.1
42600703
3 x 0.75
111
7.5
42600704
4 x 0.75
132
8.1
42600705
5 x 0.75
149
9.0
42600707
7 x 0.75
215
9.8
42601002
2x1
126
7.8
42601003
3x1
141
8.3
42601004
4x1
167
9.1
42601005
5x1
196
10.1
42601007
7x1
282
10.9
42601502
2 x 1.5
149
8.9
42601503
3 x 1.5
173
9.5
42601504
4 x 1.5
191
10.3
42601505
5 x 1.5
216
11.3
42601507
7 x 1.5
314
12.2
Part No.
Cores x mm²
Weight kg/km
O/D mm
42602502 42602503 42602504 42602505 42602507
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5
206 263 299 329 471
10.3 10.8 11.9 13.0 14.4
42604003 42604004
3x4 4x4
295 376
16.2 17.4
42606003 42606004
3x6 4x6
390 459
19.2 20.8
42610003 42610004
3 x 10 4 x 10
882 1049
42606004E
FS
FS
FS
cables
FS
FS
FS
FS
FS
25.3 28.6
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
Weight kg/km
cables
Cores x mm²
Test 3.5kV
cables
88
SIGNAL & CONTROL Def-Standard PVC
Def-Standard PVC Multicore Originally developed for military use, these cables are now widely used within industry. They offer compact sizing, high working voltage and a large range of sizes to suit most applications. A robust and economical choice which can also be oversheathed or armoured for duct installation or direct burial. These cables should not be used as mains connection cables. Applications include data processing, information transfer, process control and security as well as many industrial applications. Construction Unscreened type 'A' has fine tinned copper wire strands, colour coded PVC insulation, cores twisted together, PVC outer sheath. Screened type 'C' has an overall polyester tape with tinned copper wire braid screen. Screened type 'S' has an overall aluminium/polyester foil screen and tinned copper drain wire. Individually Screened type 'D' has a tinned copper wire braid screen around each core. Duct grade versions have a heavy duty black LDPE sheath over the standard PVC sheath. Type â&#x20AC;&#x2DC;Râ&#x20AC;&#x2122; uses 37 x 0.315mm stranding (2.9mm2) and has a overall tinned copper wire braid like type C. Normally packed on 100m, 500m or 1000m spools, cables can also be cut to length when required. For colour codes up to 36 cores see page 167. Part No.
Size
No. of Cores
Weight kg/km
O/D mm
2 3 4 6 9 12 15 18 25 36 50
7 8 10 14 18 24 27 32 42 63 76
2.5 2.6 2.8 3.3 3.9 4.3 4.5 5.4 5.8 6.4 7.3
2 3 4 6 8 9 12 15 18 25 36 50
9 11 17 22 25 27 44 46 54 64 83 114
3.0 3.2 3.4 3.8 4.2 4.4 4.6 5.4 5.8 6.6 7.2 8.3
2 3 4 6 8 12 18 20 25 36
14 17 22 32 47 56 82 90 100 146
3.4 3.5 3.8 4.8 5.6 6.4 7.4 7.8 8.7 9.8
Unscreened 7/0.1mm - 0.055mm2
39300212
39200102 39200103 39200104 39200106 39200109 39200112 39200115 39200118 39200125 39200136 39200150
7-1-2A 7-1-3A 7-1-4A 7-1-6A 7-1-9A 7-1-12A 7-1-15A 7-1-18A 7-1-25A 7-1-36A 7-1-50A
Braid Screen 7/0.1mm - 0.055mm2 cables
FS
FS cables
39300102 39300103 39300104 39300106 39300108 39300109 39300112 39300115 39300118 39300125 39300136 39300150
7-1-2C 7-1-3C 7-1-4C 7-1-6C 7-1-8C 7-1-9C 7-1-12C 7-1-15C 7-1-18C 7-1-25C 7-1-36C 7-1-50C
Unscreened 7/0.2mm - 0.22mm2
cables
FS
FS cables
39200202 39200203 39200204 39200206 39200208 39200212 39200218 39200220 39200225 39200236
7-2-2A 7-2-3A 7-2-4A 7-2-6A 7-2-8A 7-2-12A 7-2-18A 7-2-20A 7-2-25A 7-2-36A
www.fscables.com
sales@fscables.com
89
Def-Standard PVC SIGNAL & CONTROL Technical Information Voltage Rating: Temperature Rating: Bend Radius: Current Rating: Nominal Conductor Max. Resistance @ 20째C:
Part No.
Size
0.055mm2 0.22mm2,0.5mm2 & 2.9mm2 0째C to +70째C Static 7.5 cable diameter 0.055mm2 0.25 amps 0.055mm2 348 Ohm/km 2.9mm2 6.79 Ohm/km
No. of Cores
Weight kg/km
O/D mm
250V rms up to 1600Hz 440V rms up to 1600Hz
39400508 0.22mm2 1 amp
0.5mm2 2.5 amps
0.22mm2 92 Ohm/km
0.5mm2 40.1 Ohm/km
Part No.
Size
No. of Cores
Weight kg/km
O/D mm
Unscreened 16/0.2mm - 0.5mm2
Unscreened Duct 7/0.2mm - 0.22mm2 39200206D 7-2-6A
6
52
6.8
39200502
16-2-2A
2
35
5.5
39200208D 7-2-8A
8
56
7.1
39200503
16-2-3A
3
42
5.8
39200212D 7-2-12A
12
68
8.4
39200504
16-2-4A
4
54
6.3
39200506
16-2-6A
6
76
7.3
39200508
16-2-8A
8
88
8.6
39200512
16-2-12A
12
120
9.5
39200518
16-2-18A
18
180
11.0
39200525
16-2-25A
25
265
12.5
39200536
16-2-36A
36
341
14.1 6.5
Foil Screened Duct 7/0.2mm - 0.22mm2 39400206D 7-2-6S
6
53
7.1
39400208D 7-2-8S
8
58
7.6
39400212D 7-2-12S
12
72
9.0
Braid Screen 7/0.2mm - 0.22mm2 39300202
7-2-2C
2
25
3.8
39300203
7-2-3C
3
29
4.0
39300204
7-2-4C
4
33
4.3
39300206
7-2-6C
6
57
Braid Screen 16/0.2mm - 0.5mm2 39300502
16-2-2C
2
71
39300503
16-2-3C
3
82
6.8
5.6
39300504
16-2-4C
4
97
7.3 8.3
39300208
7-2-8C
8
66
6.2
39300506
16-2-6C
6
130
39300212
7-2-12C
12
87
6.9
39300508
16-2-8C
8
152
8.8
39300215
7-2-15C
15
105
7.6
39300512
16-2-12C
12
202
10.5
39300218
7-2-18C
18
115
8.4
39300518
16-2-18C
18
270
12.0
39300220
7-2-20C
20
124
8.6
39300525
16-2-25C
25
350
14.1
39300225
7-2-25C
25
153
9.5
39300536
16-2-36C
36
475
16.1
39300236
7-2-36C
36
207
10.7
Ind. Braid Screen Cores 16/0.2mm - 0.5mm2 16-2-4D
4
93
7.5
7-2-2S
2
23
3.7
39600506
16-2-6D
6
121
8.8
39400203
7-2-3S
3
28
4.0
39600507
16-2-7D
7
134
39600512
16-2-12D
12
188
7-2-4S
4
31
4.1
39400206
7-2-6S
6
52
4.8
39400208
7-2-8S
8
60
5.7
39400212
7-2-12S
12
79
6.2
39400218
7-2-18S
18
103
7.9
39400225
7-2-25S
25
141
39400236
7-2-36S
36
175
FS
Foil Screen Cored or Paired 16/0.2mm - 0.5mm2 39400501P
16-2-1PS 1 Pair
38
5.2
39400502P
16-2-2PS 2 Pair
79
7.9
39400502
16-2-2S
2
47
5.0
39400503
16-2-3S
3
56
8.8
39400504
16-2-4S
4
61
10.5
39400506
16-2-6S
6
75
39400508
16-2-8S
8
89
Ind. Braid Screen Cores 7/0.2mm - 0.22mm2
FS 6.0 6.8
cables 7.6
2
21
4.3
39400512
16-2-12S
12
132
9.7
7-2-3D
3
28
4.6
39400518
16-2-18S
18
198
12.6
39600204
7-2-4D
4
38
5.1
39400525
16-2-25S
25
269
14.0
39600206
7-2-6D
6
56
6.0
39400536
16-2-36S
36
387
39600212
7-2-12D
12
112
8.2
39600218
7-2-18D
18
151
9.5
37-3-2R
2
150
39302903
37-3-3R
3
200
10.5
39302904
37-3-4R
4
250
11.0
15.9
cables
39302902
FS
Fax : 01727 840 842
FS cables
6.8
FS
cables
FS
cables
7-2-2D
39600203
Braid Screen 37/0.315mm - 2.9mm2
FS
8.2
39600202
Tel: 01727 840 841
cables
39400204
8.9
11.1
cables
39600504
39400202
Foil Screened 7/0.2mm - 0.22mm2
FS cables
90
SIGNAL & CONTROL Def-Standard LSHF
Def-Standard LSHF Multicore For installations that call for Low Smoke Halogen Free signal cables the Niltox range of LSHF miniature multicores are the ideal solution. Manufactured in the style of the Def Style PVC multicores on pages 88-89, these cables are suitable for use in public buildings & sensitive areas as they contain no Halogen emitting compounds. Screened and unscreened options are held in stock. This cable is not suitable for direct connection to the mains. Construction
Technical Information
Fine tinned copper wire strands, colour coded Low
Voltage Rating:
440V rms up to 1600Hz
Smoke Halogen Free insulation, cores laid-up with
Temperature Rating:
0ยบC to +70ยบC
a Low Smoke Halogen Free outer sheath. Screened type
Current Rating:
0.22mm2 1amp
'C' has a polyester tape with a tinned copper braid
Nominal Conductor
screen. Screened type 'S' has an aluminium foil screen
Max. Resistance @ 20ยบC: 0.22mm2 - 92 ohms per km 0.5mm2 - 40.1 ohms per km
and tinned copper drain wire.
Part No.
Size
No. of Cores
Weight kg/km
Bending Radius:
Static 7.5 x cable diameter.
Flame Retardant:
IEC 60332-1-2
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
O/D mm
LSHF Unscreened 7/0.2mm - 0.22mm2
39200206H
cables
FS cables
cables
FS
FS cables
Part No.
Size
No. of Cores
Weight kg/km
O/D mm
LSHF Unscreened 16/0.2mm - 0.5mm2
39200202H
7-2-2A
2
14
3.4
39200502H
16-2-2A
2
35
5.5
39200203H
7-2-3A
3
17
3.5
39200503H
16-2-3A
3
42
5.8
39200204H
7-2-4A
4
22
3.8
39200504H
16-2-4A
4
54
6.3
39200206H
7-2-6A
6
32
4.8
39200506H
16-2-6A
6
76
7.3
39200208H
7-2-8A
8
47
5.6
39200508H
16-2-8A
8
96
8.6
39200212H
7-2-12A
12
56
6.4
39200512H
16-2-12A
12
120
9.5
39200218H
7-2-18A
18
82
7.4
39200518H
16-2-18A
18
180
11.0
39200225H
7-2-25A
25
100
8.7
39200525H
16-2-25A
25
274
14.1
39200236H
7-2-36A
36
146
9.8
LSHF Braided Screened 16/0.2mm - 0.5mm2 39300502H
16-2-2C
2
71
6.5
39300202H
7-2-2C
2
25
3.8
39300503H
16-2-3C
3
82
6.8
39300203H
7-2-3C
3
29
4.0
39300504H
16-2-4C
4
97
7.3
39300204H
7-2-4C
4
33
4.3
39300506H
16-2-6C
6
130
8.3
39300206H
7-2-6C
6
57
5.6
39300508H
16-2-8C
8
152
8.8
39300208H
7-2-8C
8
66
6.2
39300512H
16-2-12C
12
202
10.5
39300212H
7-2-12C
12
87
6.9
39300518H
16-2-18C
18
270
12.0
39300218H
7-2-18C
18
115
8.4
39300525H
16-2-25C
25
350
14.1
39300225H
7-2-25C
25
153
9.5
39300536H
16-2-36C
36
475
16.1
39300236H
7-2-36C
36
207
10.7
LSHF Braided Screened 7/0.2mm - 0.22mm2
FS
0.5mm2 2.5amps
LSHF Foil Screened 7/0.2mm - 0.22mm2
LSHF Foil Screened 16/0.2mm - 0.5mm2 39400501PH 16-2-1PS 1 Pair
47
5.2
39400202H
7-2-2S
2
23
3.7
39400502PH 16-2-2PS 2 Pair
68
7.6
39400203H
7-2-3S
3
28
4.0
39400502H
16-2-2S
2
47
5.0
39400204H
7-2-4S
4
31
4.1
39400503H
16-2-3S
3
56
6.0
39400206H
7-2-6S
6
52
4.8
39400504H
16-2-4S
4
61
6.8
39400208H
7-2-8S
8
60
5.7
39400506H
16-2-6S
6
75
7.6
39400212H
7-2-12S
12
79
6.2
39400508H
16-2-8S
8
89
8.2
39400218H
7-2-18S
18
103
7.9
39400512H
16-2-12S
12
132
9.7
39400225H
7-2-25S
25
141
8.8
39400518H
16-2-18S
18
198
12.6
www.fscables.com
sales@fscables.com
91
SIGNAL & CONTROL Niltox® LF-316 LSHF LF-249 H05Z-K & H07Z-K (2491B & 6701B)
2491B and 6701B are flexible single cores with class 5 stranding conforming to the harmonisation standard H05Z-K and H07Z-K for Low Smoke Halogen Free single core cable. Applications include panel and conduit wiring where its flexibility makes installation easier. Public and government buildings are increasingly using LSHF cabling to reduce the risk of injury through smoke inhalation in the event of a fire. The cables also produce less corrosive gases when burnt, which is particularly important where sensitive electronic equipment is installed such as in computer rooms.
Construction
Technical Information
Plain fine copper wire strands to IEC 60228 class 5. Thermosetting insulation of Low Smoke Halogen Free compound to BS 7211.
Voltage Rating:
300/500V
Up to 1.0mm2
1.5mm2 and above 450/750V Temperature Rating:
-15°C to +90°C
Current Rating:
4E1A & B
Conductor Stranding:
To IEC 60228 Class 5.
Manufactured to:
BS 7211: 1994
Flame Retardant to:
IEC 60332-1-2
24901501
BASEC approval available on many from stock. If required, please check at time of enquiry. Part No.
Size mm2
No. of Strands/mm
Weight kg/km
O/D mm
249005xx
0.5
16/0.20
10
249007xx
0.75
24/0.20
13
2.4
249010xx
1.0
32/0.20
16
2.5
249015xx
1.5
30/0.25
21
2.9
249025xx
2.5
50/0.25
33
3.6
249040xx
4.0
56/0.30
49
4.2
249060xx
6.0
84/0.30
70
5.0
249100xx
10
80/0.40
125
6.4
249160xx
16
126/0.40
180
8.0
249250xx
25
196/0.40
275
9.5
249350xx
35
276/0.40
380
11.7
249500xx
50
400/0.40
560
12.4
249700xx
70
356/0.50
780
14.5
249950xx
95
485/0.50
1000
17.0
249120xx
120
614/0.50
1300
17.7
249150xx
150
765/0.50
1600
19.5
249185xx
185
944/0.50
2000
22.0
249240xx
240
1225/0.50
2600
2.1
24916099
FS
FS
FS
FS
FS
FS
25.3 cables
cables
FS
cables
FS
cables
To show the colour required please replace xx in the part number with: 04
White
08
Orange
Blue
05
Grey
09
Yellow
02
Brown
06
Violet
10
Green
03
Red
07
Pink
99
Green/Yellow
Standard pack size for conductor sizes up to and including 16mm2 is 100m, with some sizes/colours stocked on 500m reels. 25mm2 and above is normally stocked on bulk reels and can be cut to the length you require. Not all colours are available in the larger sizes.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
Black
01
cables
00
cables
92
SIGNAL & CONTROL SY PVC
SY PVC Steel Braided Multicore Where mechanical protection is called for on a flexible cable, SY is a popular choice. The tough, flexible, clear outer sheath provides excellent abrasion and oil resistance. Suitable as a supply or control cable for motors, plant, machinery and many other applications.
Construction
Technical Information
Fine copper wire strands to IEC 60228 Class 5.
Voltage Rating:
300/500V
Black PVC insulation with white numbers or colour
Temperature Rating:
Static -20°C to +80°C Flexing -5°C to +70°C
coded. Cables with more than 2 cores include a Bending Radius:
green/yellow earth, cores twisted together. Grey
Static 10 x cable diameter Flexing 20 x cable diameter
PVC inner sheath, steel wire braid, clear PVC outer Current Rating:
sheath. Part No.
11001504
cables
FS
FS cables
cables
FS
FS cables
Cores x mm²
Test 3000V
Weight kg/km
O/D mm
Number Coded 11000502 2 x 0.5 11000503 3 x 0.5 11000504 4 x 0.5 11000505 5 x 0.5 11000507 7 x 0.5 11000512 12 x 0.5 11000518 18 x 0.5 11000525 25 x 0.5 11000534 34 x 0.5 11000550 50 x 0.5
73 86 96 107 132 211 261 374 498 665
7.1 7.6 8.0 8.5 9.3 11.5 13.4 15.8 17.4 20.9
11000702 11000703 11000704 11000705 11000707 11000712 11000718 11000725 11000734 11000750
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 34 x 0.75 50 x 0.75
91 93 106 119 158 221 279 397 510 755
7.6 7.8 8.3 8.9 9.7 12.2 13.6 16.7 18.9 23.1
11001002 11001003 11001004 11001005 11001007 11001012 11001018 11001025 11001034 11001050
2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 34 x 1.0 50 x 1.0
96 104 109 127 152 238 326 479 579 848
8.2 8.4 8.8 9.3 9.9 12.5 14.5 17.9 19.3 22.1
www.fscables.com
Refer to IEE Regs Table 4F3A&B Part No.
Cores x mm²
Weight kg/km
O/D mm
11001502 11001503 11001504 11001505 11001507 11001512 11001518 11001525 11001542
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 25 x 1.5 42 x 1.5
102 122 146 158 214 321 464 625 959
8.5 8.7 9.3 9.9 12.4 13.7 16.8 19.8 23.4
11002502 11002503 11002504 11002505 11002507 11002512 11002518
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5
152 169 212 223 295 499 685
9.8 10.1 10.9 11.8 13.0 17.3 19.8
11004003 11004004 11004005 11004007
3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0
241 286 342 460
11.7 12.6 13.9 15.7
11006003 11006004 11006005 11006007
3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0
354 397 496 613
14.1 14.8 16.9 18.4
11010004 11010005 11010007
4 x 10 5 x 10 7 x 10
638 766 979
18.2 19.8 22.2
11016004 11016005 11025004 11025005 11035004 11050004 11070004 11095004
4 x 16 5 x 16 4 x 25 5 x 25 4 x 35 4 x 50 4 x 70 4 x 95
996 1159 1383 1758 1938 2689 3583 4935
21.8 23.5 25.3 28.9 29.7 34.9 44.8 47.8
sales@fscables.com
93
SY PVC SIGNAL & CONTROL Part No.
Cores x mm²
Weight kg/km
O/D mm
Colour Coded
Part No.
Cores x mm²
Weight kg/km
O/D mm
11006003C
3 x 6.0
549
14.7
11000702C
2 x 0.75
91
7.6
11006004E
4 x 6.0
583
15.9
11000703C
3 x 0.75
93
7.8
11006005E
5 x 6.0
674
17.4
11000704E
4 x 0.75
106
8.3
11006007C
7 x 6.0
853
19.1
11000705E
5 x 0.75
119
8.9
11000707C
7 x 0.75
181
12.6
11010003C
3 x 10
744
18.2
11000712C
12 x 0.75
284
12.7
11010004E
4 x 10
956
20.3
11010005E
5 x 10
1091
22.1
11001002C
2 x 1.0
96
8.2
11001003C
3 x 1.0
104
8.4
11016003C
3 x 16
1108
21.2
11001004E
4 x 1.0
109
8.8
11016004E
4 x 16
1395
23.2
11001005E
5 x 1.0
127
9.3
11016005E
5 x 16
1773
25.8
11001007E
7 x 1.0
342
10.8
11001012E
12 x 1.0
343
13.4
11025003C
3 x 25
1681
26.1
11025004E
4 x 25
2103
29.3
11025005E
5 x 25
2529
32.0
11001502C
2 x 1.5
102
8.5
11001503C
3 x 1.5
122
8.7
11001504E
4 x 1.5
146
9.3
11035003C
3 x 35
1973
31.9
11001505E
5 x 1.5
158
9.9
11035004E
4 x 35
2621
32.5
11001507C
7 x 1.5
286
12.7
11035005E
5 x 35
3268
36.2
11001512C
12 x 1.5
446
14.9 11050003C
3 x 50
2731
37.8
11002502C
2 x 2.5
152
9.8
11050004E
4 x 50
3613
38.5
11002503C
3 x 2.5
169
10.1
11050005E
5 x 50
4367
43.9
11002504E
4 x 2.5
212
10.9
11002505E
5 x 2.5
223
11.8
11070003C
3 x 70
2832
46.2
11002507C
7 x 2.5
427
15.4
11070004E
4 x 70
4893
47.4
11002512C
12 x 2.5
665
18.3
11070005E
5 x 70
11004003C
3 x 4.0
241
11.7
11095003C
3 x 95
11004004E
4 x 4.0
286
12.6
11095004E
11004005E
5 x 4.0
342
13.9
11095005E
11004007C
7 x 4.0
649
16.6 11120004E
4 x 120
49.1
4 x 95
6423
51.8
5 x 95
8162
56.5
8235
56.8
cables
4996
FS
cables
11150004E
4 x 150
10324
Blue
Brown
3 core
Blue
Brown
Green/Yellow
Tel: 01727 840 841
4 core
Blue
Black
5 core
Blue
Brown
Grey Black
Fax : 01727 840 842
Green/Yellow Grey
FS cables
63.2
FS
cables
cables
FS
Colour Code: 2 core
FS
52.5
cables
FS
5869
Green/Yellow
FS
cables
FS cables
94
SIGNAL & CONTROL CY PVC
CY PVC Bedded Screened Multicore N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Protecting signals from electromagnetic interference (EMI) or reducing electromagnetic radiation (EMR) from supply cables has substantially increased the need for screened multicore cables. Fine copper wire strands insulated with PVC and combined with pliable oil resistant PVC inner and outer sheaths ensure excellent flexibility, while the tinned copper wire braid forms an effective screen. Clear white numbering on black cores enable fast ‘right first time’ termination, vital when working with large numbers of cores or under artificial lighting which may distort core colours. CY has many uses including general wiring in machine tool applications especially in conjunction with PLC or microprocessor controlled manufacturing operations where signal interference could cause major problems. Also used as a supply cable where circumstances result in power and data cables being run in close proximity to each other. In these cases EMR can be significantly reduced. Construction
Technical Information
Fine copper wire strands to IEC 60228 Class 5. Black PVC
Voltage Rating:
300/500V
insulation with white numbers, a green/yellow earth
Temperature Rating:
Static -20°C to +80°C Flexing -5°C to +70°C
conductor in cables with more than 2 cores. (Colour coded versions also available). Cores twisted together. Grey PVC
Bending Radius:
inner sheath, tinned copper wire braid, clear PVC outer Current Rating:
sheath. Part No.
12001007
cables
FS
FS cables
cables
FS
FS cables
12000502 12000503 12000504 12000505 12000507 12000512 12000518 12000525 12000702 12000703 12000704 12000705 12000707 12000712 12000718 12000725 12001002 12001003 12001004 12001005 12001007 12001012 12001018 12001025 12001041
Test 3000V
Cores x mm²
Weight kg/km
O/D mm
2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 25 x 0.5 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 41 x 1.0
91 102 114 126 155 213 338 406 102 118 134 158 183 263 393 544 117 134 154 182 202 346 476 644 1008
6.8 7.4 7.9 8.6 9.2 11.6 13.4 15.5 7.2 7.7 8.3 8.9 9.7 12.1 15.3 16.8 7.6 8.1 8.6 9.7 10.5 13.4 15.6 18.1 22.1
www.fscables.com
Part No.
Static 10 x cable diameter Flexing 20 x cable diameter Refer to IEE Regs Table 4F3A&B
Cores x mm²
Weight kg/km
O/D mm
12001502
2 x 1.5
142
8.6
12001503
3 x 1.5
165
9.1
12001504
4 x 1.5
189
10.1
12001505
5 x 1.5
223
10.6
12001507
7 x 1.5
268
11.5
12001512
12 x 1.5
441
15.1
12001518
18 x 1.5
626
17.4
12002503
3 x 2.5
214
10.4
12002504
4 x 2.5
258
11.3
12002505
5 x 2.5
306
12.9
12002507
7 x 2.5
422
13.9
12004004
4 x 4.0
411
13.5
12004005
5 x 4.0
482
14.8
12006004
4 x 6.0
533
15.9
12006005
5 x 6.0
657
17.4
12010004
4 x 10
932
19.1
12010005
5 x 10
1085
22.6
12016004E
4 x 16
1195
22.3
12025004E
4 x 25
1918
32.5
12035004E
4 x 35
2516
35.6
12050004E
4 x 50
3374
38.7
12070004E
4 x 70
3819
43.8
12095004E
4 x 95
5859
47.9
12120004E
4 x 120
7351
58.2
sales@fscables.com
95
SIGNAL & CONTROL Equipment Wire LSHF Equipment Wire LSHF
The FSC range of LSHF equipment wire is intended for use with electronic equipment within public buildings, control panels, higher temperature applications, military and commercial data processing, in fact anywhere where the safety of people and property is essential.
Construction
Technical Information
Fine tinned copper wire strands, high performance LSHF insulation.
Voltage Rating:
600V AC
Temperature Rating:
-40°C to +120°C
Test 3000V AC
Minimum Bending Radius: 6 x Overall Diameter
Part No.
AWG
Stranding & mm
CSA mm2
249E3007xx
30
7/0.10
0.057
249E2807xx
28
7/0.13
0.089
249E2619xx
26
19/0.10
249E2419xx
24
249E2219xx 249E2216xx 249E2019xx
Weight kg/km
O/D mm
DC Resistance @ 20°C (Ohms/km)
0.9
0.70
355
1.2
0.78
225
0.155
1.9
0.88
135
19/0.13
0.241
2.7
1.00
85.9
22
19/0.16
0.382
4.0
1.16
53.1
-
16/0.20
0.50
5.2
1.28
40.1
20
19/0.20
0.597
6.2
1.36
32.4
249E2024xx
-
24/0.20
0.75
7.5
1.45
26.7
249E1819xx
18
19/0.25
0.963
9.5
1.60
20.4
249E1832xx
-
32/0.20
1.00
9.5
1.60
20.0
249E1619xx
16
19/0.29
1.229
12.0
1.36
15.7
249E1630xx
-
30/0.25
1.50
14.8
2.00
13.7
249E1419xx
14
19/0.36
1.870
18.5
2.21
10.0
249E1450xx
-
50/0.25
2.50
24.0
2.45
8.21
249E1237xx
12
37/0.32
2.976
29.0
2.74
6.62
Equipment Wire
Resistant to some oils, fuels and acids. Please check at time of order if critical. We are also able to offer LSHF equipment wire to Def-Stan 61-12 Part 18/5.
FS
cables
FS
FS
FS
FS
FS
cables
FS
cables
FS
cables
Versions that have both high (+200ºC) and lower (-60ºC) temperature ratings are also available. To show the colour required please replace xx in the part number with: 04
White
08
Orange
Blue
05
Grey
09
Yellow
02
Brown
06
Violet
10
Green
03
Red
07
Pink
99
Green/Yellow
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
Black
01
cables
00
cables
96
POWER Single Core Enhanced Circuit Integrity
Single Core Enhanced Circuit Integrity Designed for fixed installations where circuit integrity is critical in the event of a fire. The Low Smoke Halogen Free insulation also ensures minimal fumes and smoke are given off providing safety for both personnel and property. Maximum fire performance requires installation in either metal conduit or trunking.
Construction
Technical Information
Stranded plain copper conductor to IEC 60228 Class 2,
Voltage Rating:
0.6/1kV
mica glass tape, LSHF insulation.
Temperature Rating:
-40ºC to +90ºC
Minimum Bending Radius: 8 x cable diameter Flame Retardant:
IEC 60332-1-2, IEC 60332-3-24C
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2, EN 50267-2-1
Fire Resistant:
BS 6387 Categories CWZ (when applied to a single cable appropriately protected in steel conduit)
3871600199
Part No.
cables
FS
FS
Size mm²
No. of Strands/mm
Weight kg/km
Maximum O/D mm
Conductor Res @ 20°C Ohms/km
3871501xx
1.5
7/0.53
33
3.9
12.10
3872501xx
2.5
7/0.67
43
4.6
7.41
3874001xx
4.0
7/0.85
56
5.2
4.61
3876001xx
6.0
7/1.04
87
5.7
3.08
38710001xx
10
7/1.35
150
7.3
1.83
38716001xx
16
7/1.70
201
8.2
1.15
38725001xx
25
7/2.14
323
9.9
0.727
38735001xx
35
7/2.52
415
10.8
0.524
38750001xx
50
19/1.78
553
13.4
0.387
38770001xx
70
19/2.14
776
15.3
0.268
38795001xx
95
19/2.52
1149
17.8
0.193
38712001xx
120
37/2.03
1426
19.3
0.153
38715001xx
150
37/2.25
1731
21.5
0.124
38718501xx
185
37/2.52
2158
23.8
0.0991
38724001xx
240
61/2.25
2931
26.8
0.0754
38730001xx
300
61/2.52
3549
29.8
0.0601
cables
Some sizes and colours are also LPCB approved. If you need this please state at time of enquiry. To show the colour required please replace xx in the part number with: cables
FS
FS cables
00
Black
04
White
08
Orange
01
Blue
05
Grey
09
Yellow
02
Brown
06
Violet
10
Green
03
Red
07
Pink
99
Green/Yellow
www.fscables.com
sales@fscables.com
97
BS 5467 Armoured POWER BS 5467 Armoured PVC Power Cables - 0.6/1kV
BS 5467 cables are used for mains or low voltage power and control circuits. They offer excellent mechanical protection from damage through the use of a heavy galvanised steel wire armour. The GSWA armour and black UV stable water resistant PVC jacket makes them suitable for use inside and outside buildings or for direct burial in the ground.
Construction
Technical Information
Plain copper conductors to IEC 60228 class 2 (stranded), XLPE
Voltage Rating:
insulation, PVC inner sheath, galvanised steel wire armour,
Conductor Stranding: IEC 60228 class 2 shaped or circular
PVC sheath – black.
Temperature Rating:
Core Identification
Bending Radius :
1.5mm² to 16mm²: 6 x overall diameter
2 Core
Brown, blue
Flame Retardant:
IEC 60332-1-2
3 Core
Brown, black, grey
Manufactured To:
BS 5467 / BS 60502
4 Core
Brown, black, grey, blue
5 Core
Brown, black, grey, blue, green/yellow
0.6/1kV -15°C to +90°C max conductor temperature
If a Low Smoke Halogen Free (LSHF) version is required please
7 Core and above, including all sizes of auxiliary cables - White cores with black numbering
Part No.
Cores x mm²
as BS6436, please call for details. Weight kg/km
12.3 12.8 13.5 15.1 15.1 15.9 13.6 14.1 15.0 17.1 17.1 16.3 14.7 15.3 16.4 19.7 19.7 19.7 15.9 16.6 18.7 19.6 cables 18.0 20.0 21.1 20.0 22.0 22.9
54600103E
FS
FS
FS
FS
FS
FS
FS
FS
cables
cables
7.7 8.2 8.9 10.6 10.6 10.9 9.0 9.5 10.4 12.5 12.5 12.1 10.1 10.7 11.8 14.2 14.2 13.9 11.3 11.5 13.2 14.0 13.2 13.9 15.6 14.5 15.8 17.2
O/D mm
cables
305 338 381 426 426 490 352 397 452 549 549 600 419 481 563 810 810 950 498 569 795 865 764 869 1064 900 1159 1410
Dia. over bedding
cables
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 5 x 1.5 7 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 5 x 2.5 7 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 5 x 4.0 5 x 4.0 7 x 4.0 2 x 6.0 3 x 6.0 4 x 6.0 5 x 6.0 2 x 10* 3 x 10* 4 x 10* 2 x 16* 3 x 16* 4 x 16*
A version with PVC insulation and PVC sheath is also available
cables
54600102E 54600103E 54600104E 54600105E 54600105AUX 54600107 54600202E 54600203E 54600204E 54600205E 54600205AUX 54600207 54600402E 54600403E 54600404E 54600405E 54600405AUX 54600407 54600602E 54600603E 54600604E 54600605E 54601002E 54601003E 54601004E 54601602E 54601603E 54601604E
use BS6724 which can be found on page 98.
*Circular or compacted circular stranded conductors (class 2) Weights and dimensions will vary from manufacturer, if critical please check at time of order. Other conductor sizes and core counts available upon request
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
98
POWER BS 6724 Armoured LSHF
BS 6724 Armoured LSHF Power – 0.6/1kV BS 6724 mains voltage armoured power and control cables are manufactured using Low Smoke Halogen Free compounds. This makes them ideal for use in public buildings, tunnels and areas of increased safety such as refineries and power stations where mechanical damage and fire risk is a concern.
Construction
Technical Information
Plain copper conductors to IEC 60228 class 2, XLPE insulation,
Voltage Rating: 0.6/1kV Conductor Stranding: IEC 60228 class 2 shaped or circular Temperature Rating: -15°C to +90°C maximum conductor temperature Bending Radius: 1.5mm² to 16mm²: 6 x overall diameter Flame Retardant: IEC 60332-1-2, IEC 60332-3-24 cat C Smoke Emission: IEC 61034-2, BS EN 50268 Halogen Emission: IEC 60754-2, BS EN 50267 Manufactured To: BS 6724 / IEC 60502
LSHF bedding, galvanised steel wire armour, black LSHF Sheath. Core Identification 2 Core
Brown, blue
3 Core
Brown, black, grey
4 Core
Brown, black, grey, blue
5 Core Brown, black, grey, blue, green/yellow 7 Core and above, including all sizes of auxiliary cables White cores with black numbering
Part No.
72400604E
cables
FS
FS cables
cables
FS
FS cables
72400102E 72400103E 72400104E 72400105E 72400105AUX 72400107 72400202E 72400203E 72400204E 72400205E 72400205AUX 72400207 72400402E 72400403E 72400404E 72400405E 72400405AUX 72400407 72400602E 72400603E 72400604E 72400605E 72401002E 72401003E 72401004E 72401005E 72401602E 72401603E 72401604E
Cores x mm²
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 5 x 1.5 7 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 5 x 2.5 7 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 5 x 4.0 5 x 4.0 7 x 4.0 2 x 6.0 3 x 6.0 4 x 6.0 5 x 6.0 2 x 10* 3 x 10* 4 x 10* 5 x 10* 2 x 16* 3 x 16* 4 x 16*
We are also able to supply fire resistant versions such as Prysmian FP 400, Draka Firetuf power and Nexans NX 400. Please specify sizes and quantity and if you require a specific manufacturer. Weight kg/km
305 338 381 426 426 490 352 397 452 549 549 600 419 481 563 810 810 950 498 639 795 865 764 908 1064 1222 900 1220 1410
Dia. over bedding
O/D mm
7.7 8.2 8.9 10.6 10.6 10.9 9.0 9.5 10.4 12.5 12.5 12.1 10.1 10.7 11.8 14.2 14.2 13.9 11.3 12.0 13.2 14.0 13.2 14.0 15.6 17.1 14.5 15.5 17.2
12.3 12.8 13.5 15.1 15.1 15.9 13.6 14.1 15.0 17.1 17.1 16.3 14.7 15.3 16.4 19.7 19.7 19.7 15.9 16.6 18.7 19.6 18.0 19.5 21.1 22.5 20.0 21.2 22.9
*Circular or compacted circular stranded conductors (class 2) Weights and dimensions will vary from manufacturer, if critical please check at time of order. Other conductor sizes and core counts are available upon request
www.fscables.com
sales@fscables.com
99
Safe-T-Shield POWER Safe-T-Shield N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
Safe-T-Shield Low Smoke Halogen Free cable offers substantial advantages over conventional wiring methods. It is ideal for fixed wiring in hospitals, airports, computer rooms and other sensitive environments. The high level of screening ensures substantially reduced levels of electromagnetic interference (EMI) making it the right choice where electromagnetic capability (EMC) is a priority. Safe-T-Shield is manufactured and tested to the performance criteria of BS 8436. Because it is faster to install and lighter than small armoured cables or conduit, cost savings of up to 40% can be achieved. If the cable is pierced or accidentally cut the aluminium screen and CPC minimise the chance of personal injury. This cable is an alternative to Multi-Plus and we are also able to supply Prysmian LSX® Brand. Construction
Technical Information
Plain copper wire strands to IEC 60228 class 2, Halogen Free
Voltage Rating:
0.6/1kV
XLPE insulation to BS 6899, full size tinned copper earth
Temperature Rating:
-10°C to +90°C
conductor to IEC 60228 class 2, longitudinal aluminium tape,
Sheath Colour:
Low Smoke Halogen Free sheath to BS EN 50267-2-1 & BS EN 61034-2.
Part No.
38801502E
Cores x mm²
2 E 1.5
Conductor Stranding/mm
7/0.53
White, other colours on request All cables have a full size bare earth or CPC.
Current Rating:
Refer to IEE Regs table 4E2A
Flame Retardant:
IEC 60332-1-2
Smoke Emission:
IEC 61034-2
Halogen Emission:
IEC 60754-1 & 2
Weight kg/km
O/D mm
105
9.8
38801503E
3 E 1.5
7/0.53
140
10.3
38801504E
4 E 1.5
7/0.53
160
11.2
38802502E
2 E 2.5
7/0.67
137
10.6
38802503E
3 E 2.5
7/0.67
184
11.1
38802504E
4 E 2.5
7/0.67
258
12.9
7/0.85
209
11.3
7/0.85
267
13.1
38804004E
4 E 4.0
7/0.85
320
14.2
38806002E
2 E 6.0
7/1.04
260
13.2
38806003E
3 E 6.0
7/1.04
330
14.2
38806004E
4 E 6.0
7/1.04
455
14.9
FS
FS
FS
cables
FS
FS
FS
FS
FS
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Standard pack size 100m or 500m. Large sizes can be cut to the length required. Available in black in some sizes, please put B after the part number when ordering. A 300/500V grade, Safe-T-Shield Lite is also available.
cables
2 E 4.0 3 E 4.0
cables
38804002E 38804003E
38802502E
cables
100
POWER NYY
NYY: PVC/PVC Unarmoured PowerScreened, – 0.6/1kV Fire Resistant (IEC 60331) N2XCH-FE180/E90: XLPE/Cu/LSHF LSHF Power Cable – 0.6/1kV
NYY cables are an economical solution to power and control wiring where mechanical protection is not required. Used both indoor and outdoor these cables are suitable for direct burial or through ducts, local regulations permitting. Originating in Germany they are now popular in many parts of the world where cost, weight and size savings through not having an armour can offer many benefits. They are also easy to gland and terminate and require less containment. Construction
Technical Information
Plain copper wire conductors to IEC 60228 class 1 or 2, PVC
Voltage Rating:
insulation, bedding compound, PVC sheath – black.
Conductor Stranding: ≤ 16 mm² solid. IEC 60228 class 1
0.6/1kV
Temperature Rating:
-30°C to +70°C fixed -5°C to +70°C for installation
Bending Radius:
Single core 15 x overall diameter Multi core 12 x overall diameter
Flame Retardant:
VDE 0472 test B, IEC 60332-1-2, EN 50265-2-1
Manufactured To:
VDE 0276 pt 603 up to 5 core, pt 627 for 7 core & above, IEC 60502
NYY can be supplied with a green/yellow earth conductor reference NYY-J or without an earth conductor – reference NYY-O. Core Identification Type
NYY-J with protective earth
1 Core
Green/yellow
Black
2 Core
-
Brown, blue
3 Core
Brown, blue, G/Y earth
Brown, black, grey
4 Core
Brown, black, grey, G/Y earth
Brown, black, grey, blue
NYY-O without protective earth
5 Core
Brown, black, grey, blue, G/Y earth
Black, blue, brown, grey, black
7 Core and above
Number coded with a G/Y earth
Number coded
FS -
cables
Part No. NYY-J
Part No. NYY-O
Cores x mm²
Weight kg/km
O/D mm
N0100102E
2 x 1.5
165
11.0
N0100103E
N0100103
3 x 1.5
185
12.5
N0100104E
N0100104
4 x 1.5
220
13.0
N0100105E
N0100105
5 x 1.5
275
13.5
N0100107E
N0100107
7 x 1.5
355
15.0
N0100110E
N0100110
10 x 1.5
525
18.5
N0100112
12 x 1.5
565
19.0
N0100114E
N0100114
14 x 1.5
615
20.5
N0100116E
N0100116
16 x 1.5
695
20.5
N0100119E
N0100119
19 x 1.5
755
21.5
-
N0100121
21 x 1.5
825
21.5
N0100124E
N0100124
24 x 1.5
945
24.5
N0100130E
N0100130
30 x 1.5
1105
25.5
FS
cables N0100112E
cables
FS
FS cables
www.fscables.com
sales@fscables.com
101
NYY POWER Part No. NYY-J
Part No. NYY-O
Cores x mm²
Weight kg/km
O/D mm
2 x 2.5
210
12.0
N0100203
3 x 2.5
235
13.0
N0100204E
N0100204
4 x 2.5
285
13.5
N0100205E
N0100205
5 x 2.5
350
14.5
N0100207E
-
7 x 2.5
445
16.0
N0100210E
-
10 x 2.5
625
20.0
N0100212E
-
12 x 2.5
675
20.5
N0100214E
-
14 x 2.5
785
21.0
N0100216E
-
16 x 2.5
865
22.5
N0100219E
-
19 x 2.5
920
23.0
N0100221E
-
21 x 2.5
1045
23.5
N0100224E
-
24 x 2.5
1395
26.0
N0100230E
-
30 x 2.5
1445
28.5
N0100401E
N0100401
1 x 4.0
100
9.0
-
N0100402E
2 x 4.0
295
14.0
N0100403E
N0100403
3 x 4.0
325
16.0
N0100404E
N0100404
4 x 4.0
395
17.0
N0100405E
N0100405
5 x 4.0
475
18.0
N0100601E
N0100601
1 x 6.0
125
9.5
-
N0100602E
2 x 6.0
355
15.5
N0100603E
N0100603
3 x 6.0
420
16.0
N0100604E
N0100604
4 x 6.0
515
18.5
N0100605E
N0100605
5 x 6.0
615
19.5
N0101001
N0101001
1 x 10
185
9.5
-
N0101002E
2 x 10
490
16.5
N0101003
N0101003
3 x 10
585
18.0
N0101004
N0101004
4 x 10
725
20.0
N0101005
N0101005
5 x 10
885
21.5
N0101601E
N0101601
1 x 16
245
10.0
-
N0101602E
2 x 16
665
19.0
N0101603E
N0101603
3 x 16
810
20.5
N0101604E
N0101604
4 x 16
1055
22.0
N0101605E
N0101605
5 x 16
1250
N0100604E
FS
FS
FS
FS
FS
FS
FS
FS
24.0 cables
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
cables
cables
Larger sizes up to 630mm² can be supplied cut to length on short lead-times, please call us with your specific requirement.
cables
N0100202E
N0100203E
cables
-
cables
102
MOG BS 6883 0.6/1kV Shipwiring Power
N2XCH-FE180/E90: XLPE/Cu/LSHF BS 6883 0.6/1kV Shipwiring PowerScreened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Originally designed for wiring ships, BS 6883 cables have been widely adopted in other marine installations including oil rigs and platforms. They are available in single and multi core versions both unarmoured (type 657 SW4) and with a galvanized steel wire braid armour (type 658 SW4) for mechanical protection. Construction
Technical Information
657 SW4 Unarmoured
Voltage Rating:
0.6/1kV
Tinned stranded copper conductor, EPR insulation, SW4 LSHF
Conductor Stranding:
IEC 60228 Class 2, tinned copper
elastomeric outer sheath – black.
Temperature Rating:
-30°C to +85°C
Bending Radius Static:
657 SW4
658 SW4
≤ 10mm2
3 x cable OD
4 x cable OD
658 SW4 Armoured Tinned stranded copper conductor, EPR insulation, Halogen Free elastomeric bedding, galvanized steel wire braid armour, SW4 LSHF elastomeric outer sheath - black.
>10mm2 to 25mm2
4 x cable OD
4 x cable OD
> 25mm2
6 x cable OD
6 x cable OD
Oxygen Index of Sheath: >31%
Core Identification
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-22 Cat A
Smoke Emission:
IEC 61034-1 & 2, BS 7622
White cores with black numbers. Colour coded cores available to order. Halogen Emission: Manufactured To:
Part No.
65702512H
cables
FS
FS cables
cables
FS
FS cables
Cores x mm²
Weight kg/km
BS6883 657 SW4 Unarmoured 65701501H 1 x 1.5 42 65701502H 2 x 1.5 105 65701503H 3 x 1.5 130 65701504H 4 x 1.5 155 65701507H 7 x 1.5 260 65701512H 12 x 1.5 405 65701519H 19 x 1.5 590 65701527H 27 x 1.5 820 65702501H 1 x 2.5 57 65702502H 2 x 2.5 145 65702503H 3 x 2.5 180 65702504H 4 x 2.5 215 65702507H 7 x 2.5 365 65702512H 12 x 2.5 585 65702519H 19 x 2.5 860 65704001H 1 x 4.0 82 65704002H 2 x 4.0 225 65704003H 3 x 4.0 270 65704004H 4 x 4.0 355 65706001H 1 x 6.0 105 65706002H 2 x 6.0 285 65706003H 3 x 6.0 350 65706004H 4 x 6.0 445 65710001H 1 x 10 165 65710002H 2 x 10 445 65710003H 3 x 10 565 65710004H 4 x 10 700
O/D mm
6.0 8.5 9.0 10.0 12.0 15.5 19.0 22.0 6.0 9.5 10.0 11.0 13.0 18.0 21.0 7.0 11.5 12.0 13.0 7.0 13.0 13.5 14.5 8.0 14.5 15.5 17.0
www.fscables.com
Part No.
IEC 60754-1 & 2, BS 6425-1 BS 6883/UKOOA
Cores x mm²
Weight kg/km
65716001H
1 x 16
230
9.5
65716002H
2 x 16
630
17.0
65716003H
3 x 16
795
18.0
65716004H
4 x 16
1010
20.0
65725001H
1 x 25
360
12.0
65725002H
2 x 25
965
21.0
65725003H
3 x 25
1240
22.0
65725004H
4 x 25
1570
25.5
65735001H
1 x 35
425
12.5
65735002H
2 x 35
1140
23.0
65735003H
3 x 35
1480
25.0
65735004H
4 x 35
1880
27.0
65750001H
1 x 50
570
14.0
65750002H
2 x 50
1520
26.0
65750003H
3 x 50
1960
28.5
65750004H
4 x 50
2510
32.0
65770001H
1 x 70
785
16.0
65770002H
2 x 70
2070
31.0
65770003H
3 x 70
2700
33.0
65770004H
4 x 70
3490
36.0
65795001H
1 x 95
1060
18.0
65795003H
3 x 95
3680
37.0
65795004H
4 x 95
4780
42.0
65712001H
1 x 120
1300
21.0
65712003H
3 x 120
4490
42.0
65712004H
4 x 120
5830
46.0
sales@fscables.com
O/D mm
BS 6883 0.6/1kV Shipwiring Power MOG Part No.
Cores x mm²
280 310 390 570 780 1080 1430 320 400 460 650 980 1350 1810 420 505 590 510 595 700 680 780 935 960 1120 1370 1250 1500 1850 1455 1950 2380 2160 2640 3300 2930 3630 4340 4720 5830 5820 7180
10.0 10.5 11.5 14.0 18.5 22.0 26.5 11.0 11.5 12.5 15.0 20.0 24.0 29.5 12.0 13.0 14.0 13.0 14.0 15.5 15.0 16.0 18.0 17.5 18.5 20.5 21.0 22.5 25.0 23.5 25.0 28.0 27.0 29.0 32.5 31.0 33.0 37.0 38.0 42.5 41.0 46.0
BS6883 658 SW4 Armoured 65801502H 2 x 1.5 65801503H 3 x 1.5 65801504H 4 x 1.5 65801507H 7 x 1.5 65801512H 12 x 1.5 65801519H 19 x 1.5 65801527H 27 x 1.5 65802502H 2 x 2.5 65802503H 3 x 2.5 65802504H 4 x 2.5 65802507H 7 x 2.5 65802512H 12 x 2.5 65802519H 19 x 2.5 65802527H 27 x 2.5 65804002H 2 x 4.0 65804003H 3 x 4.0 65804004H 4 x 4.0 65806002H 2 x 6.0 65806003H 3 x 6.0 65806004H 4 x 6.0 65810002H 2 x 10 65810003H 3 x 10 65810004H 4 x 10 65816002H 2 x 16 65816003H 3 x 16 65816004H 4 x 16 65825002H 2 x 25 65825003H 3 x 25 65825004H 4 x 25 65835002H 2 x 35 65835003H 3 x 35 65835004H 4 x 35 65850002H 2 x 50 65850003H 3 x 50 65850004H 4 x 50 65870002H 2 x 70 65870003H 3 x 70 65870004H 4 x 70 65895003H 3 x 95 65895004H 4 x 95 65812003H 3 x 120 65812004H 4 x 120
O/D mm
13.5 14.5 16.5 18.0 23.5 27.5 32.0 14.5 16.0 17.0 20.0 25.0 29.0 34.5 16.5 17.0 19.0 18.0 18.5 20.0 20.0 20.5 23.0 23.0 24.0 26.0 26.0 27.5 30.0 28.0 30.0 33.5 32.5 34.0 38.5 37.0 39.0 43.0 44.0 cables 49.0 48.5 54.0
FS
FS
FS
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
65802512H
cables
Dia. over Bedding mm
cables
Weight kg/km
103
cables
104
MOG BS 6883 657-SW4 Shipwiring Instrumentation
N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) BS 6883 657-SW4 Unarmoured Shipwiring Instrumentation LSHF Power Cable – 0.6/1kV Manufactured in both pairs and triples these 150/250V marine instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or where difficult routing is necessary these cables are ideal where no additional mechanical protection is required. Using SW4 Low Smoke Halogen Free sheathing compounds ensures that in the event of a fire the cable offers excellent protection to both people and property by not emitting toxic or corrosive gases.
Construction
Electrical Characteristics
Collectively Screened
Conductor Size:
0.75mm²
1.5mm²
Tinned copper wire conductors to IEC 60228 class 2, EPR
Conductor Resistance:
<24.5 Ohms/km
<12.1 Ohms/km
insulation, cores twisted into pairs or triples, overall foil screen
Insulation Resistance:
940 MOhm x km
730 MOhm x km
and drain wire, SW4 oil resistant LSHF sheath - grey, blue or
Mutual Capacitance @ 800Hz:
black.
Individual Screen:
90nF/km
110nF/km
Collective Screen:
80nF/km
90nF/km
Individually Screened Tinned copper wire conductors to IEC 60228 class 2, EPR
Technical Information
insulation, cores twisted into pairs or triples, each pair or triple aluminum foil screened with a drain wire, SW4 oil
Voltage Rating:
150/250V
Conductor Stranding:
IEC 60228 Class 2,
resistant LSHF sheath – grey, blue or black.
tinned copper conductors
Class 5 conductors to IEC 60228 can be supplied on request.
Temperature Rating:
-30°C to +85°C
Bending Radius Static:
8 x overall diameter
Oxygen Index of Sheath: >31%
Core Identification
Flame Retardant:
Pairs - Black & white
IEC 60332-1-2, IEC 60332-3-22 Cat A, BS 4066-3
Triples - Black, white & red
Smoke Emission:
IEC 61034-1 & 2, BS 7622
Each pair is identified by a numbered tape or printed
Halogen Emission:
IEC 60754-1 & 2, BS 6425-1
numbers on the cores.
Oil Resistant:
BS 7655 SW4 section 2.6
Manufactured To:
BS 6883/UKOOA
Part No. cables
FS
Pairs Collectively Screened 657C0702PHxx 657C0703PHxx 657C0707PHxx 657C0712PHxx 657C0719PHxx 657C0720PHxx 657C0727PHxx
FS cables
657C1502PHxx 657C1503PHxx 657C1507PHxx 657C1512PHxx 657C1520PHxx 657C1527PHxx cables
FS
FS cables
No. of Pairs
mm2
Weight kg/km
O/D mm
2 3 7 12 19 20 27
0.75 0.75 0.75 0.75 0.75 0.75 0.75
180 210 380 610 875 975 1210
12.5 13.0 18.0 23.5 27.0 28.5 32.5
2 3 7 12 20 27
1.5 1.5 1.5 1.5 1.5 1.5
271 310 601 900 1310 1780
14.0 15.8 20.0 26.0 30.5 32.5
www.fscables.com
sales@fscables.com
BS 6883 657-SW4 Shipwiring Instrumentation MOG Part No.
mm2
Weight kg/km
O/D mm
1 2 3 7 12 20 27
0.75 0.75 0.75 0.75 0.75 0.75 0.75
95 165 260 480 750 1150 1600
8.1 12.0 13.0 18.5 22.5 28.0 31.5
1 2 3 7 12 20
1.5 1.5 1.5 1.5 1.5 1.5
135 254 300 690 1110 1850
16.5 14.3 15.0 21.0 27.0 34.5
mm2
Weight kg/km
O/D mm
0.75 0.75 0.75
260 501 805
15.0 20.5 25.0
1.5 1.5 1.5
350 790 1250
15.5 23.4 28.5
0.75 0.75 0.75 0.75
110 300 580 971
8.5 15.0 19.5 25.0
1.5 1.5 1.5 1.5
165 410 900 1500
9.5 17.5 25.0 28.5
No. of Pairs
Pairs Individually Screened 657I0701PHxx 657I0702PHxx 657I0703PHxx 657I0707PHxx 657I0712PHxx 657I0720PHxx 657I0727PHxx 658I1501PHxx 658I1502PHxx 657I1503PHxx 657I1507PHxx 657I1512PHxx 657I1520PHxx Part No.
No. of Triples
Triples Collectively Screened 657C0703THxx 3 657C0707THxx 7 657C0712THxx 12 657C1503THxx 657C1507THxx 657C1512THxx
3 7 12
Triples Individually Screened 657I0701THxx 1 657I0703THxx 3 657I0707THxx 7 657I0712THxx 12
To show the colour required please replace xx in the part number with: 05
Grey
01
Blue
00
Black
FS
FS
FS
cables
FS
FS
FS
FS
FS
cables
1 3 7 12
657C0707PH00
cables
657I1501THxx 657I1503THxx 657I1507THxx 657I1512THxx
105
cables
Other pair and triple configurations available on request
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
106
MOG BS 6883 658-SW4 Shipwiring Instrumentation
N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) BS 6883 658-SW4 Armoured Shipwiring Instrumentation LSHF Power Cable – 0.6/1kV Similar in construction to the BS 6883 657 SW4 instrumentation types, these cables have an additional steel wire braid armour for mechanical protection. Manufactured in both pairs and triples these 150/250V marine instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. They maintain good flexibility for installation on ships and oil rigs. The SW4 Low Smoke Halogen Free sheathing is oil resistant and ensures that in the event of a fire the cable will offer excellent protection to both people and property by not emitting toxic or corrosive gases.
Construction
Electrical Characteristics
Collectively Screened
Conductor Size:
0.75mm²
1.5mm²
Tinned copper wire conductors to IEC 60228 class 2, EPR
Conductor Resistance:
<24.5 Ohms/km
<12.1 Ohms/km
insulation, cores twisted into pairs or triples, overall foil screen
Insulation Resistance:
940 MOhm x km
730 MOhm x km
and drain wire, LSHF bedding, galvanised steel wire braid,
Mutual Capacitance @ 800Hz:
SW4 oil resistant LSHF sheath - grey, blue or black.
Individual Screen:
90nF/km
110nF/km
Collective Screen:
80nF/km
90nF/km
Class 5 conductors to IEC 60228 can be supplied on request. Individually Screened
Technical Information
Tinned copper wire conductors to IEC 60228 class 2, EPR
Voltage Rating:
150/250V
insulation, cores twisted into pairs or triples, each pair or
Conductor Stranding:
IEC 60228 Class 2,
triple aluminum foil screened with a drain wire, LSHF
tinned copper conductors
bedding, galvanised steel wire braid, SW4 oil resistant LSHF
Temperature Rating:
-30°C to +85°C
sheath – grey, blue or black.
Bending Radius Static:
8 x overall diameter
Oxygen Index of Sheath: >31% Core Identification
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-22 Cat A
Pairs - Black & white
Smoke Emission:
IEC 61034-1 & 2, BS 7622
Triples - Black, white & red
Halogen Emission:
IEC 60754-1 & 2, BS 6425-1
Oil Resistant:
BS 7655 SW4 section 2.6
Manufactured To:
BS 6883/UKOOA
Each pair is identified by a numbered tape or printed numbers on the cores. Part No.
No. of Pairs
Pairs Collectively Screened 658C0702PHxx 2 658C0703PHxx 3 658C0707PHxx 7 658C0712PHxx 12 658C0719PHxx 19 658C0720PHxx 20 658C0727PHxx 27 cables
FS
FS cables
658C1502PHxx 658C1503PHxx 658C1507PHxx 658C1512PHxx 658C1520PHxx 658C1527PHxx cables
FS
FS cables
2 3 7 12 20 27
Size mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75
379 420 660 1010 1460 1570 1980
13.5 12.0 16.5 21.5 24.5 25.5 29.0
15.5 16.5 21.0 26.0 29.5 31.5 35.5
1.5 1.5 1.5 1.5 1.5 1.5
477 520 821 1291 2130 2650
14.0 15.0 18.5 24.5 29.0 33.5
17.5 18.5 23.0 30.0 35.5 40.0
www.fscables.com
sales@fscables.com
BS 6883 658-SW4 Shipwiring Instrumentation MOG Part No.
No. of Pairs
Pairs Individually Screened 658I0701PHxx 1 658I0702PHxx 2 658I0703PHxx 3 658I0707PHxx 7 658I0712PHxx 12 658I0720PHxx 20
Weight kg/km
Dia. over Bedding mm
230 420 530 721 1111 1701
7.5 11.0 12.0 16.5 22.0 26.0
11.5 17.0 18.5 21.0 27.0 34.5
1 2 3 7 12 20
1.5 1.5 1.5 1.5 1.5 1.5
290 511 560 980 1670 2430
8.5 13.0 14.0 20.0 25.0 31.5
12.5 18.0 19.0 26.0 32.0 38.0
No. of Triples
Size mm²
Triples Collectively Screened 658C0703THxx 3 658C0707THxx 7 658C0712THxx 12 658C1503THxx 3 658C1507THxx 7 658C1512THxx 12 Triples Individually Screened 658I0701THxx 1 658I0703THxx 3 658I0707THxx 7 658I0712THxx 12
Dia. over Bedding mm
0.75 0.75 0.75
510 820 1290
13.5 18.0 24.0
18.0 22.5 29.0
1.5 1.5 1.5
520 1280 1840
14.5 20.5 27.5
19.5 26.5 33.5
0.75 0.75 0.75 0.75
245 530 898 1530
8.0 14.0 18.5 25.0
12.0 18.5 23.5 31.0
1.5 1.5 1.5 1.5
320 690 1390 2105
9.0 15.5 23.0 29.5
13.0 20.5 27.5 34.5
To show the colour required please replace xx in the part number with: Grey
01
Blue
O/D mm
00
Black
Other pair and triple configurations available on request
FS
FS
FS
cables
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
1 3 7 12
Weight kg/km
658C0707PH05
cables
658I1501THxx 658I1503THxx 658I1507THxx 658I1512THxx
05
O/D mm
0.75 0.75 0.75 0.75 0.75 0.75
658I1501PHxx 658I1502PHxx 658I1503PHxx 658I1507PHxx 658I1512PHxx 658I1520PHxx
Part No.
Size mm²
107
cables
108
MOG BS 7917 0.6/1kV Shipwiring Power
BS 7917 0.6/1kV Shipwiring PowerScreened, – Fire Resistant N2XCH-FE180/E90: XLPE/Cu/LSHF Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Used widely on ships, oil rigs, platforms and refineries where fire resistance to IEC 60331 is vital. BS 7917 cables provide circuit integrity to maintain essential services in the event of a fire. The 657M SW4 unarmoured versions are ideal for applications where small bending radii are required. When mechanical protection is needed the 658M SW4 steel braid armour (GSWB) version provides the solution whilst maintaining good flexibility for installation in restricted areas. Construction
Technical Information
657M SW4 Unarmoured
Voltage Rating:
0.6/1kV
Stranded tinned copper conductor, mica glass tape fire barrier,
Conductor Stranding:
IEC 60228 Class 2, tinned copper
EPR insulation, SW4 LSHF elastomeric outer sheath – black.
Temperature Rating:
-30°C to +85°C
Single core cables are available in green/yellow for earthing
Bending Radius Static:
657M SW4
658M SW4
applications.
≤ 10mm2
3 x cable OD
4 x cable OD
>10mm2 to 25mm2
4 x cable OD
4 x cable OD
> 25mm2
6 x cable OD
6 x cable OD
658M SW4 Armoured Stranded tinned copper conductor, mica glass tape fire barrier, EPR insulation, halogen free thermoplastic elastomeric bedding, galvanized steel wire braid armour, SW4 LSHF elastomeric outer sheath - black. Core Identification White cores with black numbers. Colour coded cores available to order. Part No.
Cores x mm²
Weight kg/km
Oxygen Index of Sheath: >31% Fire Resistant:
IEC 60331-21
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-22 Cat A
Smoke Emission:
IEC 61034-1 & 2, BS 7622
Halogen Emission:
IEC 60754-1 & 2, BS 6425-1
Manufactured To:
BS 7917 / BS 6883
O/D mm
BS 7917 657M SW4 Unarmoured 65701512HM
cables
FS
FS cables
cables
FS
FS cables
Part No.
Cores x mm²
Weight kg/km
O/D mm
65706003HM
3 x 6.0
350
13.5
65701501HM
1 x 1.5
42
6.0
65706004HM
4 x 6.0
445
14.5
65701502HM
2 x 1.5
105
8.5
65710001HM
1 x 10
165
8.0
65701503HM
3 x 1.5
130
9.0
65710002HM
2 x 10
445
14.5
65701504HM
4 x 1.5
155
10.0
65710003HM
3 x 10
565
15.5
65701507HM
7 x 1.5
260
12.0
65710004HM
4 x 10
700
17.0
65701512HM
12 x 1.5
405
15.5
65716001HM
1 x 16
230
9.5
65701519HM
19 x 1.5
590
19.0
65716002HM
2 x 16
630
17.0
65701527HM
27 x 1.5
820
22.0
65716003HM
3 x 16
795
18.0
65702501HM
1 x 2.5
57
6.0
65716004HM
4 x 16
1010
20.0
65702502HM
2 x 2.5
145
9.5
65725001HM
1 x 25
360
12.0
65702503HM
3 x 2.5
180
10.0
65725002HM
2 x 25
965
21.0
65702504HM
4 x 2.5
215
11.0
65725003HM
3 x 25
1240
22.0
65702507HM
7 x 2.5
365
13.0
65725004HM
4 x 25
1570
25.5
65702512HM
12 x 2.5
585
18.0
65735001HM
1 x 35
425
12.5
65702519HM
19 x 2.5
860
21.0
65735002HM
2 x 35
1140
23.0
65704001HM
1 x 4.0
82
7.0
65735003HM
3 x 35
1480
25.0
65704002HM
2 x 4.0
225
11.5
65735004HM
4 x 35
1880
27.0
65704003HM
3 x 4.0
270
12.0
65750001HM
1 x 50
570
14.0
65704004HM
4 x 4.0
355
13.0
65750002HM
2 x 50
1520
26.0
65706001HM
1 x 6.0
105
7.0
65750003HM
3 x 50
1960
28.5
65706002HM
2 x 6.0
285
13.0
65750004HM
4 x 50
2510
32.0
www.fscables.com
sales@fscables.com
109
BS 7917 0.6/1kV Shipwiring Power MOG Part No.
65770001HM 65770002HM 65770003HM 65770004HM 65795001HM
Cores x mm²
Weight kg/km
O/D mm
1 x 70 2 x 70 3 x 70 4 x 70 1 x 95
785 2070 2700 3490 1060
16.0 31.0 33.0 36.0 18.0
Part No.
65795003HM 65795004HM 65712001HM 65712003HM 65712004HM
Cores x mm²
Weight kg/km
O/D mm
3 x 95 4 x 95 1 x 120 3 x 120 4 x 120
3680 4780 1300 4490 5830
37.0 42.0 21.0 42.0 46.0
65801512HM
For green/yellow single cores suffix the part code "E" Part No.
Cores x mm²
Tel: 01727 840 841
Fax : 01727 840 842
13.5 14.5 16.5 18.0 23.5 27.5 32.0 14.5 16.0 17.0 20.0 25.0 29.0 34.5 16.5 17.0 19.0 18.0 18.5 20.0 20.0 20.5 23.0 23.0 24.0 26.0 26.0 27.5 30.0 28.0 30.0 33.5 32.5 cables 34.0 38.5 37.0 39.0 43.0 44.0 49.0 48.5 54.0
FS
FS
FS
FS
FS
FS
FS
FS
cables
cables
cables
10.0 10.5 11.5 14.0 18.5 22.0 26.5 11.0 11.5 12.5 15.0 20.0 24.0 29.5 12.0 13.0 14.0 13.0 14.0 15.5 15.0 16.0 18.0 17.5 18.5 20.5 21.0 22.5 25.0 23.5 25.0 28.0 27.0 29.0 32.5 31.0 33.0 37.0 38.0 42.5 41.0 46.0
cables
280 310 390 570 780 1080 1430 320 400 460 650 980 1350 1810 420 505 590 510 595 700 680 780 935 960 1120 1370 1250 1500 1850 1455 1950 2380 2160 2640 3300 2930 3630 4340 4720 5830 5820 7180
BS 7917 658M SW4 Armoured 65801502HM 2 x 1.5 65801503HM 3 x 1.5 65801504HM 4 x 1.5 65801507HM 7 x 1.5 65801512HM 12 x 1.5 65801519HM 19 x 1.5 65801527HM 27 x 1.5 65802502HM 2 x 2.5 65802503HM 3 x 2.5 65802504HM 4 x 2.5 65802507HM 7 x 2.5 65802512HM 12 x 2.5 65802519HM 19 x 2.5 65802527HM 27 x 2.5 65804002HM 2 x 4.0 65804003HM 3 x 4.0 65804004HM 4 x 4.0 65806002HM 2 x 6.0 65806003HM 3 x 6.0 65806004HM 4 x 6.0 65810002HM 2 x 10 65810003HM 3 x 10 65810004HM 4 x 10 65816002HM 2 x 16 65816003HM 3 x 16 65816004HM 4 x 16 65825002HM 2 x 25 65825003HM 3 x 25 65825004HM 4 x 25 65835002HM 2 x 35 65835003HM 3 x 35 65835004HM 4 x 35 65850002HM 2 x 50 65850003HM 3 x 50 65850004HM 4 x 50 65870002HM 2 x 70 65870003HM 3 x 70 65870004HM 4 x 70 65895003HM 3 x 95 65895004HM 4 x 95 65812003HM 3 x 120 65812004HM 4 x 120
O/D mm
cables
Dia. over Bedding mm
cables
Weight kg/km
cables
110
MOG BS 7917 657M-SW4 Shipwiring Instrumentation
BS 7917 657M-SW4 Fire Resistant Unarmoured Instrumentation N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, FireShipwiring Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Fire resistant instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Mica glass tape fire barriers provide circuit integrity whilst the oil resistant SW4 Low Smoke Halogen Free sheathing compound ensures protection to both people and property during a fire. Construction
Electrical Characteristics
Collectively Screened
Conductor Size:
0.75mm²
1.5mm²
Tinned copper wire conductors to IEC 60228 class 2, mica
Conductor Resistance:
<24.5 Ohms/km
<12.1 Ohms/km
glass tape fire barrier EPR insulation, cores twisted into pairs
Insulation Resistance:
940 MOhm x km 730 MOhm x km
or triples, overall foil screen and drain wire, SW4 oil resistant
Mutual Capacitance @ 800Hz:
LSHF sheath - grey, blue or black.
Collective Screen:
80nF/km
90nF/km
Individual Screen:
90nF/km
110nF/km
Individually Screened Tinned copper wire conductors to IEC 60228 class 2, mica glass
Technical Information
tape fire barrier, EPR insulation, cores twisted into pairs or triples, each pair or triple aluminum foil screened with a drain
Voltage Rating:
150/250V
wire, SW4 oil resistant LSHF sheath – grey, blue or black.
Conductor Stranding:
IEC 60228 Class 2, tinned copper
Temperature Rating:
-30°C to +85°C
Bending Radius Static:
8 x overall diameter
Class 5 conductors to IEC 60228 can be supplied on request.
Oxygen Index of Sheath: >31%
Core Identification Pairs - Black & white Triples - Black, white & red
Fire Resistant:
IEC 60331-21
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-22 Cat A
Each pair is identified by a numbered tape or printed numbers
Smoke Emission:
IEC 61034-1 & 2, BS 7622
on the cores.
Halogen Emission:
IEC 60754-1 & 2, BS 6425-1
Oil Resistant:
BS 7655 SW4 section 2.6
Manufactured To:
BS 7917/UKOOA
Part No.
Pairs Collectively Screened 657C0702PHMxx 657C0703PHMxx 657C0707PHMxx 657C0712PHMxx 657C0719PHMxx 657C0720PHMxx 657C0727PHMxx cables
FS
FS cables
657C1502PHMxx 657C1503PHMxx 657C1507PHMxx 657C1512PHMxx 657C1520PHMxx 657C1527PHMxx cables
FS
FS cables
No. of Pairs
mm²
Weight kg/km
O/D mm
2 3 7 12 19 20 27
0.75 0.75 0.75 0.75 0.75 0.75 0.75
180 230 410 620 900 990 1290
12.5 14.0 19.0 24.5 28.5 30.0 33.0
2 3 7 12 20 27
1.5 1.5 1.5 1.5 1.5 1.5
271 410 680 1050 1480 1860
14.0 16.5 21.0 27.5 31.5 33.0
www.fscables.com
sales@fscables.com
BS 7917 657M-SW4 Shipwiring Instrumentation MOG Part No.
No. of Pairs
Pairs Individually Screened 657I0701PHMxx 657I0702PHMxx 657I0703PHMxx 657I0707PHMxx 657I0712PHMxx 657I0720PHMxx 657I0727PHMxx 658I1501PHMxx 658I1502PHMxx 657I1503PHMxx 657I1507PHMxx 657I1512PHMxx 657I1520PHMxx
Part No.
mm²
Weight kg/km
O/D mm
1 2 3 7 12 20 27
0.75 0.75 0.75 0.75 0.75 0.75 0.75
120 165 280 510 850 1300 1710
9.5 12.0 14.0 19.5 23.5 29.0 33.0
1 2 3 7 12 20
1.5 1.5 1.5 1.5 1.5 1.5
145 254 350 760 1210 1990
17.5 14.3 16.5 23.0 29.0 35.5
mm²
Weight kg/km
O/D mm
0.75 0.75 0.75
280 530 820
16.0 22.0 26.5
1.5 1.5 1.5
375 815 1300
16.5 24.8 30.0
0.75 0.75 0.75 0.75
135 325 595 990
10.0 16.5 21.0 26.0
1.5 1.5 1.5 1.5
187 450 960 1610
11.0 18.5 26.0 30.5
No. of Triples
Triples Collectively Screened 657C0703THMxx 3 657C0707THMxx 7 657C0712THMxx 12 657C1503THMxx 657C1507THMxx 657C1512THMxx
3 7 12
Triples Individually Screened 657I0701THMxx 1 657I0703THMxx 3 657I0707THMxx 7 657I0712THMxx 12
To show the colour required please replace xx in the part number with: 05
Grey
01
Blue
00
Black
FS
FS
FS
cables
FS
FS
FS
FS
FS
cables
1 3 7 12
657C0707PHM00
cables
657I1501THMxx 657I1503THMxx 657I1507THMxx 657I1512THMxx
111
cables
Other pair and triple configurations available on request
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
112
MOG BS 7917 658M-SW4 Shipwiring Instrumentation
BS 7917 658M-SW4 Fire Resistant Armoured Shipwiring Instrumentation N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Manufactured with a galvanised steel wire braid for mechanical protection these fire resistant cables are available in both pairs and triples to provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility and circuit integrity their use has spread from ships to rigs and many onshore/offshore applications. The oil resistant SW4 Low Smoke Halogen Free sheathing compounds ensure that in the event of a fire the cables offer excellent protection to both people and property by not emitting toxic or corrosive gases whilst keeping emergency circuits operating. Construction
Electrical Characteristics
Collectively Screened
Conductor Size:
Tinned copper wire conductors to IEC 60228 class 2, mica glass
Conductor Resistance: <24.5 Ohms/km
<12.1 Ohms/km
tape fire barrier, EPR insulation, cores twisted into pairs or triples,
Insulation Resistance:
730 MOhm x km
overall foil screen and drain wire, LSHF bedding, galvanised steel
Mutual Capacitance @ 800Hz:
wire braid armour, SW4 oil resistant LSHF sheath - grey, blue or
Collective Screen:
80nF/km
90nF/km
black.
Individual Screen:
90nF/km
110nF/km
Individually Screened
0.75mm² 940 MOhm x km
1.5mm²
Technical Information
Tinned copper wire conductors to IEC 60228 class 2, mica glass tape fire barrier, EPR insulation, cores twisted into pairs or
Voltage Rating:
150/250V
triples, each pair aluminum foil screened with a drain wire,
Conductor Stranding:
IEC 60228 Class 2, tinned copper
LSHF bedding, galvanised steel wire braid armour, SW4 oil
Temperature Rating:
-30°C to +85°C
resistant LSHF sheath – grey, blue or black.
Bending Radius Static:
8 x overall diameter
Oxygen Index of Sheath: >31% Class 5 conductors to IEC 60228 can be supplied on request.
Fire Resistant:
IEC 60331-21
Flame Retardant:
IEC 60332-1-2,
Core Identification
IEC 60332-3-22 Cat A
Pairs - Black & white
Smoke Emission:
IEC 61034-1 & 2, BS 7622
Triples - Black, white & red
Halogen Emission:
IEC 60754-1 & 2, BS 6425-1
Oil Resistant:
BS 7655 SW4 section 2.6
Manufactured To:
BS 7917/BS 6883
Each pair is identified by a numbered tape or printed numbers on the cores.
cables
FS
Part No.
No. of Pairs
Pairs Collectively Screened 658C0702PHMxx 2 658C0703PHMxx 3 658C0707PHMxx 7 658C0712PHMxx 12 658C0719PHMxx 19 658C0720PHMxx 20 cables 658C0727PHMxx 27
FS
658C1502PHMxx 658C1503PHMxx 658C1507PHMxx 658C1512PHMxx 658C1520PHMxx 658C1527PHMxx cables
FS
FS cables
2 3 7 12 20 27
mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75
379 460 741 1120 1600 1720 2190
13.5 13.0 17.5 22.5 26.0 27.0 31.0
15.5 17.5 21.5 27.5 32.0 33.0 37.5
1.5 1.5 1.5 1.5 1.5 1.5
477 570 920 1560 2260 2820
13.5 14.5 19.5 26.0 31.0 35.5
17.5 19.0 24.0 31.5 37.5 42.0
www.fscables.com
sales@fscables.com
BS 7917 658M-SW4 Shipwiring Instrumentation MOG Part No.
No. of Pairs
mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
113
Pairs Individually Screened 658I0701PHMxx
1
0.75
260
8.0
12.0
658I0702PHMxx
2
0.75
420
11.0
17.0
658I0703PHMxx
3
0.75
480
13.5
17.5
658I0707PHMxx
7
0.75
795
20.0
22.0
658I0712PHMxx
12
0.75
1225
24.0
28.5
658I0720PHMxx
20
0.75
2050
30.0
36.5
658I0727PHMxx
27
0.75
2410
35.0
41.0
658I1501PHMxx
1
1.5
300
9.5
13.0
658I1502PHMxx
2
1.5
511
13.0
18.0
658I1503PHMxx
3
1.5
650
15.0
21.0
658I1507PHMxx
7
1.5
1030
20.5
25.0
658I1512PHMxx
12
1.5
1650
27.5
32.0
658I1520PHMxx
20
1.5
2690
34.0
41.0
mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
Part No.
No. of Triples
658C0707PHM05
Triples Collectively Screened 658C0703THMxx
3
0.75
550
15.0
19.0
658C0707THMxx
7
0.75
930
19.5
24.5
658C0712THMxx
12
0.75
1450
26.0
31.5
658C1503THMxx
3
1.5
615
15.5
19.5
658C1507THMxx
7
1.5
1010
22.0
25.0
658C1512THMxx
12
1.5
1560
26.0
29.0
Triples Individually Screened 0.75
280
8.5
12.5
3
0.75
590
14.5
19.0
658I0707THMxx
7
0.75
990
20.0
24.5
658I0712THMxx
12
0.75
1650
26.5
32.5
FS
658I1501THMxx
1
1.5
330
10.0
14.0
658I1503THMxx
3
1.5
850
16.5
19.0
658I1507THMxx
7
1.5
1180
20.0
cables 25.0
658I1512THMxx
12
1.5
1740
32.5
38.0
FS
cables
1
658I0703THMxx
cables
FS
658I0701THMxx
FS cables
To show the colour required please replace xx in the part number with: 05
Grey
01
Blue
00
Black
Fax : 01727 840 842
FS
FS
FS
cables
cables
Tel: 01727 840 841
FS
cables
Other pair and triple configurations available on request
cables
114
MOG BFOU Power to IEC 60092-353
BFOU Power to IEC 60092-353 N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV BFOU is similar to RFOU but has the benefit of mica tape around the conductor to maintain circuit integrity for 3 hours when exposed to fire in accordance with IEC 60331-21. Designed to NEK606 and IEC 60092-353 BFOU meets the most stringent fire resistant, flame retardant and low smoke emission tests making it the ideal choice for low voltage power and control applications on FPSO, ship and platform applications. Construction
Technical Information
Tinned stranded copper conductor, mica glass tape fire
Voltage Rating:
0.6/1kV
barrier, EPR insulation, halogen free thermoplastic
Conductor Stranding:
IEC 60228 Class 2, tinned copper
elastomeric bedding, tinned copper wire braid armour,
Current Rating:
FEA-M clause 1881.5 – 11 or IEE regs. table 4H2A+B depending on application
MUD resistant LSHF elastomeric outer sheath. The cross sectional area (mm2) of the screen is shown after the conductor size in the table below.
Black
2 Cores
Light grey, black
3 Cores
Light grey, black, red
4 Cores
Light grey, black, red, blue
-40°C to +85°C
Bending Radius Static:
6 x overall diameter
Oxygen Index of Sheath: >31%
Core Construction 1 Core
Temperature Rating:
5 Cores and above number coded
Fire Resistant:
IEC 60331-21
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-22 Cat A
Smoke Emission:
IEC 61034-1 & 2
Halogen Emission:
IEC 60754-1 & 2
MUD Resistant:
NEK 606 P5/P12
Manufactured To:
IEC 60092-353, NEK 606
3rd Party Approval:
DNV, approvals may vary between manufacture brands.
Cores x mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
2 x 1.5/4 3 x 1.5/4 4 x 1.5/4 7 x 1.5/6
280 310 390 570
10.0 10.5 11.5 14.0
13.5 14.5 16.5 18.0
cables
BFO01512 BFO01519 BFO01527
12 x 1.5/10 19 x 1.5/10 27 x 1.5/10
780 1080 1430
18.5 22.0 26.5
23.5 27.5 32.0
FS
BFO02502 BFO02503 BFO02504 BFO02507 BFO02512 BFO02519 BFO02527
2 x 2.5/4 3 x 2.5/6 4 x 2.5/6 7 x 2.5/6 12 x 2.5/10 19 x 2.5/10 27 x 2.5/16
320 400 460 650 980 1350 1810
11.0 11.5 12.5 15.0 20.0 24.0 29.5
14.5 16.0 17.0 20.0 25.0 29.0 34.5
FS
BFO04002 BFO04003 BFO04004 BFO06002 BFO06003 BFO06004
2 x 4/6 3 x 4/6 4 x 4/6 2 x 6/6 3 x 6/6 4 x 6/6
420 505 590 510 595 700
12.0 13.0 14.0 13.0 14.0 15.5
16.5 17.0 19.0 18.0 18.5 20.0
BFO06004
Part No.
BFOU Power BFO01502 BFO01503 BFO01504 BFO01507
FS
cables
cables
FS cables
www.fscables.com
sales@fscables.com
115
BFOU Power to IEC 60092-353 MOG Part No.
Cores x mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
BFO10002
2 x 10/10
680
15.0
20.0
BFO10003
3 x 10/10
780
16.0
20.5
BFO10004
4 x 10/10
935
18.0
23.0
BFO16002
2 x 16/16
960
17.5
23.0
BFO16003
3 x 16/16
1120
18.5
24.0
BFO16004
4 x 16/16
1370
20.5
26.0
BFO25001
1 x 25/4
480
11.5
15.5
BFO25002
2 x 25/16
1250
21.0
26.0
BFO25003
3 x 25/16
1500
22.5
27.5
BFO25004
4 x 25/16
1850
25.0
30.0
BFO35001
1 x 35/6
640
13.5
17.0
BFO35002
2 x 35/16
1455
23.5
28.0
BFO35003
3 x 35/16
1950
25.0
30.0
BFO35004
4 x 35/16
2380
28.0
33.5
BFO50001
1 x 50/6
820
15.0
19.5
BFO50002
2 x 50/25
2160
27.0
32.5
BFO50003
3 x 50/25
2640
29.0
34.0
BFO50004
4 x 50/25
3300
32.5
38.5
1 x 70/6
1080
16.5
21.0
2 x 70/35
2930
31.0
37.0
BFO70003
3 x 70/35
3630
33.0
39.0
BFO70004
4 x 70/35
4340
37.0
43.0
BFO95001
1 x 95/10
1380
18.5
BFO95003
3 x 95/50
4720
38.0
BFO95004
4 x 95/50
5830
42.5
cables
FS
23.0 44.0 49.0
FS
1 x 120/10
1710
20.5
3 x 120/60
5820
41.0
BFO12004
4 x 120/60
7180
46.0
BFO15001
1 x 150/10
2030
23.0
28.0
BFO18501
1 x 185/10
2510
25.0
30.0
BFO24001
1 x 240/16
3130
28.0
BFO30001
1 x 300/16
3820
31.0
FS
cables
Fax : 01727 840 842
cables
25.5 48.5 54.0
34.0
FS cables
FS
cables
BFO12001 BFO12003
Tel: 01727 840 841
FS
cables
BFO70001 BFO70002
37.0
FS
cables
FS cables
116
MOG BFOU Instrumentation to IEC 60092-376
BFOU Instrumentation to IEC 60092-376 N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV BFOU instrumentation cables are designed to meet the needs of circuit integrity installations within the offshore industry. They are available as collectively or individually screened options for optimum EMI screening. Fire barrier tapes are combined with a Low Smoke Halogen Free sheath to provide uninterrupted signals during a fire situation. BFOU cables are also resistant to MUD and drilling oils and meet the flame retardance requirements of IEC 60332-3-22 Cat A. Construction
Technical Information
Tinned stranded copper conductor, mica tape, EPR insulation,
Voltage Rating:
250V
overall screen of copper backed polyester tape with a stranded
Conductor Stranding:
IEC 60228 Class 2, tinned copper
copper drain wire, inner sheath of halogen free elastomeric,
Temperature Rating:
-40°C to +85°C
tinned copper wire braid armour, MUD resistant - LSHF
Bending Radius Static:
6 x overall diameter
elastomeric sheath. The individually screened version has a
Oxygen Index Of Sheath: >31%
copper backed polyester tape with a stranded copper drain wire
Fire Resistant:
IEC 60331-21
around each pair or triple.
Flame Retardant:
IEC 60332-1-2, IEC 60332-3-22 Cat A
Smoke Emission:
IEC 61034-1 & 2
Halogen Emission:
IEC 60754-1 & 2
MUD Resistant:
NEK606 Collective Screen S4/S8,
Core Identification Pairs - Light blue, black and numbered Triples – Light blue, black, brown and numbered
Individual Screen S3/S7
Electrical Characteristics Conductor Size:
0.75mm²
IEC 60092-376, NEK606
3rd Party Approval:
DNV, approvals may vary between
1.5mm²
manufacture brands.
Conductor Resistance: <26.7 Ohms/km
<13.7 Ohms/km
L/R Ratio:
26.6mH/Ohm
12.7mH/Ohm
Manufactured To:
Mutual Capacitance @ 800Hz: Collective Screen:
100nF/km
110nF/km
Individual Screen:
110nF/km
125nF/km
Part No.
No. of Pairs
mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75
340 421 450 700 915 1100 1600
10.5 12.0 12.5 16.5 19.5 21.0 26.5
14.5 15.5 16.0 21.0 23.5 25.5 31.5
1.5 1.5 1.5 1.5 1.5 1.5 1.5
450 521 600 1020 1330 1620 2450
13.0 14.0 15.0 20.0 23.5 26.0 32.0
16.5 18.4 19.0 25.0 28.5 30.5 38.5
Pairs Collectively Screened BFC00702xx 2 BFC00703xx 3 BFC00704xx 4 BFC00708xx 8 BFC00712xx 12 BFC00716xx 16 BFC00724xx 24 cables
FS
FS
BFC01502xx BFC01503xx cables BFC01504xx BFC01508xx BFC01512xx BFC01516xx BFC01524xx cables
FS
2 3 4 8 12 16 24
FS cables
www.fscables.com
sales@fscables.com
117
BFOU Instrumentation to IEC 60092-376 MOG Part No.
No. of Pairs
Pairs Individually Screened BFI00701xx 1 BFI00702xx 2 BFI00703xx 3 BFI00704xx 4 BFI00708xx 8 BFI00712xx 12 BFI00716xx 16 BFI00724xx 24 BFI01501xx BFI01502xx BFI01503xx BFI01504xx BFI01508xx BFI01512xx BFI01516xx BFI01524xx Part No.
1 2 3 4 8 12 16 24 No. of Triples
Triples Collectively Screened BFC00702Txx 2 BFC00704Txx 4 BFC00708Txx 8 BFC00712Txx 12 BFC00716Txx 16 BFC00724Txx 24 BFC01502Txx BFC01504Txx BFC01508Txx BFC01512Txx BFC01516Txx BFC01524Txx
2 4 8 12 16 24
O/D mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75
200 370 500 519 820 1075 1320 2050
7.5 11.0 12.5 15.0 17.0 20.5 23.0 29.0
11.0 14.5 16.5 18.5 21.5 25.0 27.5 34.5
1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
260 490 601 650 1140 1520 1950 2900
9.0 13.0 15.5 15.5 21.0 25.0 29.0 35.5
12.0 17.0 19.5 19.5 25.0 30.0 34.0 42.0
mm²
Weight kg/km
Dia. over Bedding mm
O/D mm
0.75 0.75 0.75 0.75 0.75 0.75
415 550 880 1180 1400 2150
12.0 14.0 18.5 22.0 24.0 30.0
15.5 18.0 23.0 26.5 29.0 35.0
1.5 1.5 1.5 1.5 1.5 1.5
550 770 1270 1720 2330 3350
14.5 17.0 22.5 27.0 30.0 37.0
18.0 21.0 27.0 32.0 35.0 43.5
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75
220 420 580 591 980 1320 1650 2520
8.0 12.0 14.0 14.5 18.5 22.5 25.5 31.5
11.0 15.0 17.0 20.0 23.0 27.0 30.0 37.5
1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
290 570 730 825 1410 1980 2620 3790
9.5 14.5 17.5 17.0 22.5 28.5 31.5 39.5
12.5 18.5 cables 20.5 21.0 27.0 33.0 37.5 46.5
05
Grey
01
Blue
00
Black
Other pair and triple configurations available on request. 2.5mm2 conductor sizes are available in some sizes, please contact us for more information.
Tel: 01727 840 841
Fax : 01727 840 842
FS
FS
FS
FS
FS
FS
FS
FS
cables
cables
cables
To show the colour required please replace xx in the part number with:
BFC0070805
cables
1 2 3 4 8 12 16 24
Dia. over Bedding mm
cables
BFI01501Txx BFI01502Txx BFI01503Txx BFI01504Txx BFI01508Txx BFI01512Txx BFI01516Txx BFI01524Txx
Weight kg/km
cables
Triples Individually Screened BFI00701Txx 1 BFI00702Txx 2 BFI00703Txx 3 BFI00704Txx 4 BFI00708Txx 8 BFI00712Txx 12 BFI00716Txx 16 BFI00724Txx 24
mm²
cables
118
RUBBER & CRANE H05RR-F
H05RR-F Multicores XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV Used extensively for trailing and flexible supply leads, these rubber cables remain flexible even at sub-zero temperatures. H05RR-F uses a standard grade rubber compound for the outer sheath and is suitable for light duty applications. Application
Technical Information
Light portable tools, temporary or portable lighting,
Voltage Rating:
Working 300/500V
extension leads for indoor or outdoor use where there
Temperature Rating:
-25°C to +60°C
is minimal physical damage expected.
Bending Radius:
Flexing 15 x cable diameter
Test 2000V
Static 6 x cable diameter Construction
Current Rating:
H05RR-F Refer to IEE Regs Table 4HF3A&B
Conductor Stranding: To IEC 60228 Class 5 &
Fine copper wire strands to IEC 60228 class 5.
VDE 0295 Class 5.
Rubber insulation colour coded to BS 7671/HD 308 S2. Cores twisted together. Black rubber outer sheath to BS 6500:2000 table 12 and BS 7919:2001 table 10.
Part No.
55101503
cables
FS
FS cables
Cores x mm²
O/D mm
55100702
2 x 0.75
6.6
55100703
3 G 0.75
7.1
55101002
2 x 1.0
7.1
55101003
3 G 1.0
7.6
55101004
4 G 1.0
8.1
55101502
2 x 1.5
8.8
55101503
3 G 1.5
9.4
55101504
4 G 1.5
10.3
55101505
5 G 1.5
10.6
55102502
2 x 2.5
10.2
55102503
3 G 2.5
10.8
55102504
4 G 2.5
12.1
55102505
5 G 2.5
11.8
G = With
Green/Yellow
X = Without
Green/Yellow
The overall diameter given has been taken from measuring actual cables, however rubber cables vary considerably in diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the stock you will be sent. Also available in a special blue sheathed version suitable for use in drinking water.
cables
FS
FS cables
www.fscables.com
sales@fscables.com
119
H07RN-F RUBBER & CRANE H07RN-F Single & Multicores
Used extensively for trailing and flexible supply leads in either single or multicore versions, these rubber cables remain flexible even at sub-zero temperatures. H07RN-F uses neoprene (PCP) for its sheath. The improved abrasion resistance and the ability to withstand many oils and chemicals make the neoprene sheathed cables suitable for the most arduous conditions. Application
Technical Information
Portable saws, grinders, welders, pumps, transformers, as temporary lighting cable and feed cable to heavy mobile equipment. Single cores and large multicores are often used as distribution cables from mobile generators.
Voltage Rating:
Working 450/750V
Temperature Rating:
-20°C to +60°C. + 85°C for static applications
Bending Radius:
Flexing 15 x cable diameter
Construction
Current Rating:
Fine copper wire strands to IEC 60228 class 5. Rubber insulation colour coded to BS 7671/HD 308 S2 (cables with over 5 cores, A07RN-F, are number coded). Cores twisted together. Black neoprene (PCP) outer sheath to BS 7919:2001 table 14.
Conductor Stranding: To IEC 60228 Class 5 & VDE 0295 Class 5.
Test 3000V
Static 6 x cable diameter
Part No.
92 111 134 48 109 137 169 206 371 546 777 1090 1300 62 162 198 244 299 461 758 1100 1590 88 220 276 343 431 116 295 370 474 585 182 522
8.3 8.9 9.7 5.9 8.7 9.7 10.7 11.6 16.0 20.0 23.5 27.5 31.0 6.5 10.6 11.4 12.6 14.0 18.2 24 24.5 32.1 7.5 12.0 13.1 14.4 16.3 8.3 13.7 14.8 16.7 18.4 10.1 18.1
Green/Yellow
X = Without
57110003 57110004 57110005 57116001 57116002 57116003 57116004 57116005 57125001 57125003 57125004 57125005 57135001 57135003 57135004 57135005 57150001 57150003 57150004 57150005 57170001 57170003 57170004 57170005 57195001 57195003 57195004 57112001 57112003 57112004 57115001 57115004 57118501 57118504 57124001 57130001
3 G 10 4 G 10 5 G 10 1 x 16 2 x 16 3 G 16 4 G 16 5 G 16 1 x 25 3 G 25 4 G 25 5 G 25 1 x 35 3 G 35 4 G 35 5 G 35 1 x 50 3 G 50 4 G 50 5 G 50 1 x 70 3 G 70 4 G 70 5 G 70 1 x 95 3 G 95 4 G 95 1 x 120 3 G 120 4 G 120 1 x 150 4 G 150 1 x 185 4 G 185 1 x 240 1 x 300
Green/Yellow
668 20.1 822 21.6 1010 24.2 250 11.4 738 21.6 906 22.6 1120 24.6 1380 27.1 361 13.4 1360 27.4 1730 30.7 2110 33.6 469 14.7 1700 29.7 2180 33.2 2680 41.3 671 17.5 2410 35.4 3060 39.2 4383 47.3 892 19.6 3180 39.6 4040 43.3 5398 56.2 1140 22.0 4070 45.2 5300 50.5 1420 24.2 4936 cables 53.7 6499 59.5 1760 26.6 8101 65.5 2090 28.8 10029 76.5 2710 32.2 3310 34.9
FS
FS
FS
FS
FS
FS
The overall diameter given has been taken from measuring actual cables, however rubber cables vary considerably in diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the stock you will be sent. Also available in a special blue sheathed version suitable for use in drinking water.
Tel: 01727 840 841
Fax : 01727 840 842
57101503
FS
cables
cables
cables
2 x 1.0 3 G 1.0 4 G 1.0 1 x 1.5 2 x 1.5 3 G 1.5 4 G 1.5 5 G 1.5 7 G 1.5 12 G 1.5 19 G 1.5 27 G 1.5 37 G 1.5 1 x 2.5 2 x 2.5 3 G 2.5 4 G 2.5 5 G 2.5 7 G 2.5 12 G 2.5 19 G 2.5 27 G 2.5 1 x 4.0 2 x 4.0 3 G 4.0 4 G 4.0 5 G 4.0 1 x 6.0 2 x 6.0 3 G 6.0 4 G 6.0 5 G 6.0 1 x 10 2 x 10
O/D mm
cables
O/D mm
Weight kg/km
cables
G = With
Weight kg/km
Cores x mm²
cables
57101002 57101003 57101004 57101501 57101502 57101503 57101504 57101505 57101507 57101512 57101519 57101527 57101537 57102501 57102502 57102503 57102504 57102505 57102507 57102512 57102519 57102527 57104001 57104002 57104003 57104004 57104005 57106001 57106002 57106003 57106004 57106005 57110001 57110002
Cores x mm²
Part No.
H07RN-F Refer to IEE Regs Table 4F1A&B
FS cables
120
RUBBER & CRANE NSHTöu
NSHTöu Drum Reeling N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV NSHTöu is designed specifically for drum reeling applications. On anything from dockside cranes to automated conveyor systems, NSHTöu copes with incredible workloads. Good UV and weather resistance makes the cable suitable for exposed outdoor installation. A special low temperature type is available to work down to -40°C. Other sizes and high tensile versions using Kevlar strain relief elements are also available. Medium and high voltage variants are available usually with red PCP outer sheaths.
Construction
Technical Information
Fine copper wire strands to IEC 60228. Rubber
Voltage Rating:
Working 0.6/1kV
insulation, 4 & 5 core colour coded, six core and above,
Temperature Rating:
Flexing -25°C to +60°C
black with white numbers. Green/yellow earth core in all
Bending Radius:
Up to 20mm diameter: 10 x cable diameter
cables. Cores twisted together with short lay length. Black neoprene (PCP) dual layer outer sheath with
Flexing above 20mm diameter:
integral textile braid.
12.5 x cable diameter Part No.
51106004
cables
FS
FS cables
Cores x mm²
Weight kg/km
O/D mm
51101504
4 x 1.5
301
15
51104005
5x4
636
21
51101505
5 x 1.5
342
16
51104008
8x4
1015
27
51101507
7 x 1.5
419
20
51106004
4x6
688
21
51101512
12 x 1.5
620
22
51106005
5x6
855
23
51101518
18 x 1.5
875
27
51110004
4 x 10
1047
26
51101524
24 x 1.5
1020
29
51110005
5 x 10
1190
28
51101530
30 x 1.5
1362
31
51116004
4 x 16
1280
29
51101542
42 x 1.5
1724
35
51116005
5 x 16
1803
32
51102504
4 x 2.5
374
17
51102505
5 x 2.5
486
19
51125004
4 x 25
2102
35
51102507
7 x 2.5
506
22
51135004
4 x 35
2751
39
51102508
8 x 2.5
704
24
51150004
4 x 50
3695
45
51102512
12 x 2.5
891
26
51170004
4 x 70
5401
49
51195004
4 x 95
6985
57
4 x 120
8294
60
4 x 150
51102516
16 x 2.5
1103
28
Part No.
51102518
18 x 2.5
1208
30
51112004
51102519
19 x 2.5
1282
31
51115004
Cores x mm²
Weight kg/km
FS cables
O/D mm
8989
65
2142
40
51102524
24 x 2.5
1562
35
51301525* 25x1.5+5x1.5(C)
51102530
30 x 2.5
1819
36
51302519* 19x2.5+5x1.5(C)
1757
34
51102536
36 x 2.5
2327
40
51302525* 25x2.5+5x1.5(C)
2010
37
51102542
42 x 2.5
2860
45
51501506
3 x (2 x 1.5)(C)
608
23
51104004
4x4
526
19
51501512
6 x (2 x 1.5)(C)
984
31
* The 5 x 1.5mm2 signal cores are individually screened.
cables
FS
Test 2500V
www.fscables.com
sales@fscables.com
121
Reelflex PUR-H RUBBER & CRANE Reelflex PUR-H Drum Reeling
Reelflex PUR-H is part of the latest generation of drum reeling cables. When compared to the standard rubber NSHTöu, Reelflex PUR-H is significantly smaller in overall diameter and lighter in weight. This allows the use of lighter winding/reeling equipment offering considerable cost savings. Ideal for use inside or in the open air, these cables emit very little smoke and are halogen free, making them suitable for sensitive applications in the event of fire. Construction
Technical Information
Fine copper strands to IEC 60228 insulated with
Voltage Rating:
Working 0.6/1kV
halogen free polyester, cores laid around a central
Temperature Rating:
Fixed Installation -50°C to +80°C
Test 2500V
Flexing -40°C to +80°C
textile suspension unit using a short length of twist. Anti-torsion braid embedded between the inner and
Bending Radius:
Flexing 6 x cable diameter
outer halogen free black polyurethane sheath. Some large sizes may have a split earth construction. Please check at time of order if this is critical.
51101504P 51101505P 51101507P 51101512P 51101518P 51101524P 51101530P 51101542P 51301525 51102504P 51102505P 51102507P 51102512P 51102518P 51102524P 51102530P 51302519 51104004P 51104005P 51106004P 51106005P 51110004P 51110005P 51116004P 51116005P 51125004P 51135004P 51150004P 51170004P 51195004P 51112004P 51115004P
4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 24 x 1.5 30 x 1.5 42 x 1.5 25 x 1.5 + 5 x 1.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5 24 x 2.5 30 x 2.5 19 x 2.5 + 5 x 1.5 4x4 5x4 4x6 5x6 4 x 10 5 x 10 4 x 16 5 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 4 x 120 4 x 150
1200 1500 2000 2500 2500 2500 2500 2500 2500 1500 1800 2500 2500 2500 2500 2500 2500 1800 2000 2000 2500 2000 2500 2500 2500 2500 2500 3000 4200 5700 7200 9000
155 178 231 359 474 590 710 980 730 208 241 308 480 679 820 970 820 281 318 372 426 611 704 924 1067 1270 1720 2630 3326 4695 5565 6933
Tel: 01727 840 841
Fax : 01727 840 842
O/D mm
10.5 11.2 12.6 16.1 17.0 21.1 23.1 27.3 23.4 11.5 12.2 13.2 19.5 19.8 24.1 27.3 24.3 12.7 13.7 14.1 15.1 17.9 19.5 22.3 cables 24.2 25.5 28.3 34.2 39.8 47.1 52.1 56.5
51102518P
FS
FS
FS
FS
FS
FS
FS
FS
cables
cables
cables
Weight kg/km
cables
Tensile Stength Newtons
cables
Cores x mm²
cables
Part No.
cables
122
RUBBER & CRANE Flat PVC Cables
Flat PVC Cables PVC Flat cables offer good low temperature durability, flexing to -15ºC. Their relatively light weight increases the options available to designers as does the tight bending radius of 10 x the thickness of the cable. Used mainly within buildings on a wide variety of applications. These cables are not suitable for use in elevators.
Construction
Technical Information
Fine copper wire strands to IEC 60228 class 5. PVC
Voltage Rating:
insulation, colour coded for cables with 2-5 cores,
0.75 & 1mm2
300/500V
1.5 - 50mm2
450/750V
six cores and above black PVC insulation with white
Temperature Rating:
Flexing -15°C to +70°C
numbers. A green/yellow earth conductor is
Bending Radius:
Flexing 10 x cable thickness
included. Cores laid parallel. Black cold resistant PVC
Current Rating:
Refer to IEE Regs Table 4F3A&B
outer sheath.
Conductor Stranding:
To IEC 60228 Class 5
58101512
cables
FS
FS cables
cables
FS
Part No.
Cores x mm²
Weight kg/km
O/D mm
58100712 58100718 58100724 58101005 58101008 58101012 58101016 58101018 58101024 58101504 58101505 58101507 58101508 58101510 58101512 58101518 58101524 58102504 58102505 58102507 58102508 58102510 58102512 58102524 58104004 58104005 58104007 58106004 58110004 58116004 58125004 58135004 58150004
12 x 0.75 18 x 0.75 24 x 0.75 5 x 1.0 8 x 1.0 12 x 1.0* 16 x 1.0* 18 x 1.0 24 x 1.0 4 x 1.5 5 x 1.5 7 x 1.5 8 x 1.5 10 x 1.5 12 x 1.5 18 x 1.5 24 x 1.5 4 x 2.5 5 x 2.5 7 x 2.5 8 x 2.5 10 x 2.5 12 x 2.5 24 x 2.5 4 x 4.0 5 x 4.0 7 x 4.0 4 x 6.0 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50
260 380 490 120 205 335 465 450 590 170 190 220 270 320 390 670 790 200 260 350 390 490 580 1200 320 400 540 432 680 970 1490 1980 2800
4.2 x 33.8 4.2 x 50.2 4.2 x 65.6 4.4 x 15.5 4.4 x 24.8 9.5 x 22.5 9.5 x 28.7 4.4 x 53.8 4.4 x 70.4 4.5 x 13.6 4.5 x 18.2 4.5 x 23.9 4.9 x 27.2 4.9 x 34.0 4.9 x 39.8 4.9 x 61.6 4.9 x 82.0 5.6 x 16.8 5.6 x 22.0 5.6 x 29.2 5.6 x 32.8 6.0 x 41.4 6.0 x 48.6 6.0 x 104 7.0 x 21.2 7.0 x 27.4 7.0 x 36.6 8.2 x 24.8 10.0 x 29.6 11.2 x 34.4 13.7 x 42.6 15.4 x 47.6 18.2 x 57.5
* Cores laid in Quad Format Low Smoke Halogen Free versions, other core combinations and individually screened cores are available on request. Please call us with your requirements.
FS cables
www.fscables.com
sales@fscables.com
123
Photovoltaic Cables RUBBER & CRANE Photovoltaic Cables With the growth in renewable energy sources the demand for specialist cables to meet specific needs has also increased. While the cables used to link solar panels to each other or to a regulator are relatively simple, the environments they operate in can be very hostile. Ultraviolet (UV) can be extremely damaging to conventional cable, breaking down standard insulation within a matter of months in some cases. Heat and weather can also be very destructive.
PV0400100
The FSC range of solar panel or PV cables are designed to work in extreme conditions with a temperature range up to 120ºC and excellent UV stability.
Construction
Technical Information
Tinned copper class 5 conductors, cross
Voltage Rating:
linked polyolefin insulation, cross linked Temperature Rating:
polyolefin sheath.
Minimum Bending Radius: Part No.
Size mm²
Stranding & mm
Electrical Resistance Ohm/km
Working
0.6/1kV
Test
3000V AC
Static
-40ºC to + 120ºC
Flexing
-40ºC to + 90ºC
4 x cable diameter Weight kg/km
O/D mm
PV02501xx
2.5
50 x 0.26
7.98
47
5.5
PV04001xx
4
56 x 0.31
4.95
76
6.1
PV06001xx
6
84 x 0.31
3.30
105
7.5
PV10001xx
10
80 x 0.41
1.91
151
8.9
PV16001xx
16
128 x 0.41
1.21
232
10.0
PV25001xx
25
200 x 0.41
0.780
342
11.4
PV35001xx
35
280 x 0.41
0.554
473
12.9
PV50001xx
50
400 x 0.41
0.386
648
15.3
PV70001xx
70
356 x 0.51
0.272
861
17.5
PV95001xx
95
485 x 0.51
0.206
1126
20.1
FS
cables
FS
Black
03
Red
FS
FS
cables
cables
00
cables
To show the colour required please replace xx in the part number with:
cables
FS
cables
FS
Cables with different insulation materials and jacket materials may be offered. If you require the cable to have specific approvals please state at time of enquiry.
Tel: 01727 840 841
Fax : 01727 840 842
FS
cables
FS cables
124
ROBOTICS Hi-Flex HF-100 & HF-100-C PUR Hi-Flex HF-100 & HF-100-C PUR Abrasion on cables that are constantly flexing is becoming a much more widespread problem. To overcome this, FS Cables have introduced the HF-100 range of polyurethane sheathed cables which will outlast conventional PVC sheathing.
22501007
The low friction polyurethane sheath resists wear caused by constant rubbing either in a cable chain or where free movement brings the cable into contact with part of the machine. Suitable for use in cable chains as well as for free movement the HF-100 range will provide a long term solution to many regular flexing applications. Both the screened and unscreened versions use fleece tapes and talcum to enable the core bundle and, where appropriate, the screening braid to move as the cable flexes. This reduces the stress imposed on the conductors and braid. Construction - HF-100
Technical Information
Very fine copper wire strands to IEC 60228 Class 6. Black polyolefin insulation with white numbers. A green/yellow earth core is included in cables with more than 2 cores. Cores twisted in layers & fleece taped. Textured grey polyurethane sheath to RAL 7001.
Voltage Rating:
Construction - HF-100-C Screened Very fine copper wire strands to IEC 60228 Class 6. Black polyolefin insulation with white numbers. A green/yellow earth core is included in cables with more than 2 cores. Cores twisted in layers & textile taped. Grey PVC inner sheath. Fleece tape. Tinned copper wire braid. Fleece wrap. Textured grey polyurethane outer sheath to RAL 7001. Part No.
cables
FS
FS
Cores x mm²
O/D mm
HF-100 20500502 20500503 20500504 20500505 20500507 20500512 20500518 20500519 20500520 20500525 20500527 20500530 20500536
2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 19 x 0.5 20 x 0.5 25 x 0.5 27 x 0.5 30 x 0.5 36 x 0.5
5.5 5.8 6.2 6.7 7.7 9.7 11.2 11.6 12.0 13.9 14.4 15.5 16.2
20500702 20500703 20500704 20500705 20500707 20500712 20500718 20500720 20500725 20500727
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 20 x 0.75 25 x 0.75 27 x 0.75
6.1 6.4 6.8 7.4 8.8 10.8 12.7 13.4 15.1 15.6
cables
cables
FS
FS cables
www.fscables.com
300/500V Working Test 3000V Temperature Rating: Flexing -30°C to+80°C Bending Radius: Flexing 5 x cable diameter Current Rating: Refer to IEE Regs Table 4F3A&B Conductor Stranding: To IEC 60228 Class 6 & VDE 0295 Table 4 Also available in 0.14mm2, 0.25mm2 and 0.34mm2 screened or unscreened with DIN47100 colour codes. Please see page 126-127. Reduced overall diameter versions are now available. Please call for details. Part No.
Cores x mm²
O/D mm
20500730 20500736
30 x 0.75 36 x 0.75
16.2 18.0
20501002 20501003 20501004 20501005 20501007 20501012 20501018 20501020 20501025 20501027 20501030 20501036
2x1 3x1 4x1 5x1 7x1 12 x 1 18 x 1 20 x 1 25 x 1 27 x 1 30 x 1 36 x 1
6.7 7.1 7.5 8.6 0.2 12.8 14.3 14.7 16.9 17.6 18.2 20.3
20501502 20501503 20501504 20501505 20501507 20501512 20501518 20501520
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 20 x 1.5
7.9 8.3 8.9 9.9 11.9 14.9 16.8 17.6
sales@fscables.com
125
Hi-Flex HF-100 & HF-100-C PUR ROBOTICS Part No.
20.8 21.1 21.7 23.5
20502503 20502504 20502505 20502507 20502512 20502518 20502525
3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5 25 x 2.5
9.8 10.7 11.5 13.5 17.3 20.3 25.0
20504004 20504005
4x4 5x4
13.1 14.8
20506004 20506005
4x6 5x6
14.9 16.9
20510004
4 x 10
19.2
20516004
4 x 16
24.0
20525004
4 x 25
26.3
Cores x mm²
O/D mm
22500502 22500503 22500504 22500505 22500507 22500512 22500518 22500520 22500525 22500527 22500530 22500536
2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 20 x 0.5 25 x 0.5 27 x 0.5 30 x 0.5 36 x 0.5
8.2 8.9 9.1 9.6 10.8 13.1 14.8 14.9 17.8 18.0 18.1 18.6
22500702 22500703 22500704 22500705 22500707 22500712 22500718 22500720 22500725
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 20 x 0.75 25 x 0.75
8.5 8.9 9.9 10.5 11.7 13.7 15.5 16.3 18.9
Part No.
Tel: 01727 840 841
O/D mm
22500727 22500730 22500736
27 x 0.75 30 x 0.75 36 x 0.75
19.0 19.0 20.4
22501002 22501003 22501004 22501005 22501007 22501012 22501018 22501020 22501025 22501027 22501030 22501036
2x1 3x1 4x1 5x1 7x1 12 x 1 18 x 1 20 x 1 25 x 1 27 x 1 30 x 1 36 x 1
8.9 9.2 9.7 10.5 12.7 14.9 16.9 16.9 21.0 21.1 21.2 22.5
22501502 22501503 22501504 22501505 22501507 22501512 22501518 22501520 22501525 22501527 22501530 22501536
2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 20 x 1.5 25 x 1.5 27 x 1.5 30 x 1.5 36 x 1.5
10.2 10.9 11.8 12.0 13.9 17.0 20.3 20.9 24.1 24.4 24.8 27.0
22502503 22502504 22502505 22502507 22502512 22502518
3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5
11.7 12.7 13.6 15.9 18.1 20.9
22506004
4x6
FS
FS
Fax : 01727 840 842
FS
cables
FS
FS
FS
FS
FS
cables
20.4
cables
cables
25 x 1.5 27 x 1.5 30 x 1.5 36 x 1.5
Cores x mm²
cables
20501525 20501527 20501530 20501536
Part No.
cables
O/D mm
cables
Cores x mm²
cables
126
ROBOTICS HF-120 Unscreened & HF-120-C Screened HF-120 Unscreened & HF-120-C Screened
20500112
Hi-Flex 120 & 120-C screened data cables are designed to last even in the most hostile chain or free movement applications. The HF-120-C copper braid screened version protects the signal from EMI while the TPE insulation supports the highly flexible conductors. Abrasion is reduced to a minimum by using a polyurethane low friction sheath. For maximum life Hi-Flex Data cables should not be exposed to torsional stresses or twisting. Many sizes now available with UL approval.
Construction - HF-120 & HF-120-C
Technical Information
Very fine copper wire strands. Polyolefin insulation colour coded to DIN 47100. Cores twisted in layers & fleece taped. (Screened versions have a tinned copper wire braid & fleece wrap). Low friction polyurethane outer sheath. Colour chart page 80.
Voltage Rating:
Part No.
22500207
cables
FS
FS cables
cables
FS
FS cables
Cores x mm²
Weight kg/km
O/D mm
HF-120 Unscreened 20500102 2 x 0.14 20500103 3 x 0.14 20500104 4 x0.14 20500105 5 x 0.14 20500107 7 x 0.14 20500110 10 x 0.14 20500112 12 x 0.14 20500114 14 x 0.14 20500118 18 x 0.14 20500125 25 x 0.14
22 27 30 36 48 63 69 73 85 125
4.1 4.4 4.7 5.0 5.8 6.0 6.1 6.7 7.0 8.3
20500202 20500203 20500204 20500205 20500207 20500210 20500212 20500214 20500218 20500225
2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 7 x 0.25 10 x 0.25 12 x 0.25 14 x 0.25 18 x 0.25 25 x 0.25
26 30 39 49 59 83 95 106 129 168
4.3 4.6 5.0 5.2 6.1 7.4 8.2 8.5 9.0 11.1
20500302 20500303 20500304 20500305 20500307 20500310 20500312 20500314 20500318 20500325
2 x 0.34 3 x 0.34 4 x 0.34 5 x 0.34 7 x 0.34 10 x 0.34 12 x 0.34 14 x 0.34 18 x 0.34 25 x 0.34
33 43 55 66 79 107 128 148 180 250
4.8 95.2 5.9 6.4 7.3 8.8 8.9 9.4 10.3 12.4
www.fscables.com
Temperature Rating: Bending Radius:
Part No.
250V Working Test 1500V Flexing -30°C to +80°C Flexing 7.5 x cable diameter
Cores x mm²
Weight kg/km
O/D mm
HF-120-C Unscreened 22500102 2 x 0.14 22500103 3 x 0.14 22500104 4 x 0.14 22500105 5 x 0.14 22500107 7 x 0.14 22500110 10 x 0.14 22500112 12 x 0.14 22500114 14 x 0.14 22500118 18 x 0.14 22500125 25 x 0.14
31 35 40 45 59 79 93 102 113 150
4.6 4.8 5.0 5.2 5.7 6.2 6.7 7.4 7.9 9.6
22500202 22500203 22500204 22500205 22500207 22500210 22500212 22500214 22500218 22500225
2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 7 x 0.25 10 x 0.25 12 x 0.25 14 x 0.25 18 x 0.25 25 x 0.25
36 41 47 63 79 10 119 139 158 196
4.8 5.4 5.7 6.1 6.7 68.3 8.6 8.8 9.5 11.5
22500302 22500303 22500304 22500305 22500307 22500310 22500312 22500314 22500318 22500324 22500325
2 x 0.34 3 x 0.34 4 x 0.34 5 x 0.34 7 x 0.34 10 x 0.34 12 x 0.34 14 x 0.34 18 x 0.34 24 x 0.34 25 x 0.34
44 58 79 86 110 153 164 183 224 319 325
5.6 6.0 6.3 6.6 7.9 9.1 9.6 9.8 10.7 13.1 13.2
sales@fscables.com
127
HF-120-C-TP Paired Screened ROBOTICS HF-120-C-TP Paired Screened The Hi-Flex twisted pair data cable is ideally suited to mechanically challenging data transmission applications. The tough polyurethane jacket is cut and abrasion resistant, while being unaffected by many solvents and oils. The tinned copper braid screen copes well with frequent flexing and at the same time maintains signal integrity by minimising the efforts of electromagnetic interference. Many sizes now available with UL approval.
Construction - HF-120-C Screened
Technical Information
Very fine copper wire strands. Polyolefin insulation colour coded to DIN 47100. Cores twisted in pairs and laid up with fleece wrap, tinned copper wire braid. Fleece wrap. Low friction polyurethane outer sheath.
Voltage Rating:
Part No.
22600201 22600202 22600203 22600204 22600205 22600206 22600208 22600210 22600214
Pairs x mm²
Weight kg/km
O/D mm
1 x 2 x 0.25 2 x 2 x 0.25 3 x 2 x 0.25 4 x 2 x 0.25 5 x 2 x 0.25 6 x 2 x 0.25 8 x 2 x 0.25 10 x 2 x 0.25 14 x 2 x 0.25
38 44 46 59 70 79 117 126 163
4.9 5.9 6.2 6.6 7.7 8.2 9.1 10.3 11.2
51 79 90 118 135 162 240 255 328
5.5 7.0 8.4 9.2 10.2 11.3 12.3 14.7 15.9
Pairs x mm²
Weight kg/km
O/D mm
22600701
1 x 2 x 0.75
108
6.1
22600702
2 x 2 x 0.75
115
8.6
22600703
3 x 2 x 0.75
123
9.6
22600704
4 x 2 x 0.75
148
10.4
22600705
5 x 2 x 0.75
180
11.5
22600706
6 x 2 x 0.75
209
12.7
22600708
8 x 2 x 0.75
305
13.8
22600710
10 x 2 x 0.75
327
16.3
22600714
14 x 2 x 0.75
420
17.8
22601001
1x2x1
108
6.3
22601002
2x2x1
128
9.1
22601003
3x2x1
140
22601004
4x2x1
171
22601005
5x2x1
206
9.9
FS
FS
FS
cables
FS
FS
FS
FS
FS
10.8 11.8
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
1 x 2 x 0.5 2 x 2 x 0.5 3 x 2 x 0.5 4 x 2 x 0.5 5 x 2 x 0.5 6 x 2 x 0.5 8 x 2 x 0.5 10 x 2 x 0.5 14 x 2 x 0.5
Part No.
250V Working Test 1500V Flexing -30°C to +80°C Flexing 10 x cable diameter
cables
22600501 22600502 22600503 22600504 22600505 22600506 22600508 22600510 22600514
Temperature Rating: Bending Radius:
22600504
cables
128
ROBOTICS HF-265 PUR Encoder HF-265 PUR Encoder
26500241
Used for precise data transmission, these cables meet the specific requirements of automation control gear manufacture. Fine copper wire strands with high performance insulation and sheathing materials make them ideal for regular flexing applications including use in cable chains where cut and abrasion resistance is vital. Manufactured to DESINA® with UL and CSA approval these cables also conform to EU low voltage guide lines 73/23/EWG ™,ensuring they are widely accepted around the world. A wide variety of core combinations are manufactured as standard but please call us to discuss your specific needs. We are constantly increasing the standard range and will produce special designs for low minimum order quantities.
Construction - HF-265 PUR Encoder
Technical Information
Very fine copper wire strands to IEC 60228 Class 6. Polyproplene insulation, colour coded. Cores twisted in layers, including screened pairs & fleece taped. Tinned copper wire braid. Fleece wrap. Low friction polyurethane outer sheath. Colour green.Please note individual types may vary in construction from the above.
Voltage Rating:
Part No.
cables
FS
FS cables
265001125 265001145 265001545 26500135 26500131 26500145 26500275 26500241 26500345 26500509 26500132 26500134 26500102 26500104 26500108 26500212 26500224 26500144
Temperature Rating: Bending Radius:
Working 300V Test 2000V Flexing -30°C to +80°C Flexing 10 x cable diameter
Cores x mm²
Weight kg/km
O/D mm
System
10 x 0.14 + 2 x 0.5 10 x 0.14 + 4 x 0.5 15 x 0.14 + 4 x 0.5 3 x (2 x 0.14) + 2 x (0.5) 3 x (2 x 0.14) + 2 x (1.0) 4 x 2 x 0.14 + 4 x 0.5 4 x 2 x 0.25 + 2 x 0.5 4 x 2 x 0.25 + 2 x 1.0 4 x 2 x 0.38 + 4 x 0.5 9 x 0.5 3 x (2 x 0.14)+4 x 0.14 + 2 x 0.5 3x(2x0.14)+4x0.14+4x0.23+2x0.5 2 x 2 x 0.18 4 x 2 x 0.18 8 x 2 x 0.18 12 x (2 x 0.25) 4 x (2 x 0.14) 4 x 2 x 0.14 + 4 x 0.25
70 86 127 101 109 111 123 135 199 126 127 149 45 57 126 208 92 97
8.1 8.5 8.9 8.2 8.5 8.3 8.9 8.9 8.7 8.7 9.1 10.2 5.7 6.6 8.7 12.6 5.9 6.3
Heidenhain Heidenhain Bosch Heidenhain/Sinumerik Heidenhain Heidenhain Indramat Indramat Sinumerik Indramat Sinumerik Sinumerik Sinumerik Sinumerik Sinumerik Sinumerik Heidenhain Heidenhain
cables
FS
FS cables
www.fscables.com
sales@fscables.com
129
HF-275 PUR Servo & Feedback Cables ROBOTICS HF-275 PUR Servo & Feedback Cables Cables combining control, signal and power cores are now commonly used in industrial automation. Fine copper wire strands with high performance insulation and sheathing material make them ideal for regular flexing applications. A wide variety of core combinations are manufactured as standard but please call us to discuss your specific needs. We are constantly increasing the standard range and will produce special designs for low minimum order quantities.
Construction - HF-275 PUR Servo
Technical Information
Power cores: very fine copper wire strands, polyolefin insulation with cores 1-3 black with white numbers, the fourth core is a green/yellow earth. Control cores: very fine copper wire strands, black TPE insulation with white numbers. Aluminium/polyester foil with a tinned copper braid screen, around each pair there is a polyester foil wrap. Power & signal cores are twisted together with very short lay lengths. Synthetic fleece with overall tinned copper wire braid, low friction polyurethane sheath.
Voltage Rating:
Part No.
EC 0.6/1kV Power cores Test V. 4000V UL/CSA 1000V Control cores Test V. 2000V Flexing -30°C to +80°C Flexing 7.5 x cable diameter
These cables have UL and CSA approval as well as meeting the requirements of DESINA®.
Weight kg/km
4G 0.75 + 2 x (2 x 0.34) 4G 1 + 2 x (2 x 0.75) 4G 1.5 + 2 x (2 x 0.5) 4G 1.5 + 2 x (2 x 0.75) 4G 2.5 + 2 x (2 x 1.5) 4G 4 + 2 x (2 x 1.5) 4G 6 + 2 x (2 x 1.5) 4G 10 + 2 x (2 x 1.5) 4G 16 + 2 x (2 x 1.5) 4G 25 + 2 x (2 x 1.5) 4G 35 + 2 x (2 x 1.5) 4G 50 + 2 x (2 x 2.5) 4G 1.5 + (2 x 1.5) 4G 2.5 + (2 x 1.5) 4G 4 + (2 x 1.5) 4G 6 + (2 x 1.5) 4G 10 + (2 x 1.5) 4G 16 + (2 x 1.5) 4G 25 + (2 x 1.5) 4G 35 + (2 x 1.5) 4G 50 + (2 x 1.5)
172 286 342 376 447 567 664 893 1298 1784 2588 3348 233 290 376 461 739 1123 1451 1919 2852
O/D mm
11.1 12.1 12.2 12.3 15.1 17.9 18.2 21.9 26.9 29.2 32.7 37.1 12.1 12.9 14.5 17.8 20.6 23.6 cables 28.1 32.1 35.3
FS
FS
FS
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
Cores x mm²
cables
275007403 275010407 275015405 275015407 275025415 275040415 275060415 275100414 275160415 275250415 275350415 275500425 275015215 275025215 275040215 275060215 275100215 275160215 275250215 275350215 275500215
Temperature Rating: Bending Radius:
275025415
cables
130
HIGH TEMPERATURE Silicone Single Cores
Silicone SiF, SiF-GL, SiD Singles N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Silicone insulated conductors offer you an economical solution to many temperature related wiring problems. Capable of working at extremes as far apart as -50°C right up to +180°C, silicone insulated cables have grown substantially in popularity. Flexibility is retained even at very low temperatures where conventional rubber or PVC cable would become brittle and crack. At high temperatures the cable performs normally. In the case of a fire, the silicone changes to form an insulating layer of SiO2 which, provided there is no movement, will maintain cable integrity in the short term. This is important in the event of a fire where equipment needs to be shut down, lighting maintained and alarm systems remain operational. Silicone is relatively inert, that is to say it gives off minimal smoke or fumes when exposed to fire. Airports, hospitals, and other public buildings use silicone cables to wire alarm, lighting, and other essential services. At high temperatures, applications include heating elements, lighting, manufacturing and food processing and for control circuits where heat is involved. At low temperatures silicone insulated cables are used in cold stores and refrigeration plants for lighting, portable equipment and motor feeds.
Technical Information Voltage Rating:
Working
300/500V
Test
2000V
Temperature Rating:
Flexing
-25°C to +180°C
Static
-50°C to +180°C
Static
-50°C to +180°C
SiD Bending Radius:
Flexing
SiF
15 x cable diameter
SiD
Static
7.5 x cable diameter
Static
7.5 x cable diameter
Current Rating:
Refer to IEE Regs Table 4F2A&B
Conductor Stranding:
Flexible cables
To IEC 60228 Class 5 & VDE 0295 Class 5
SiD
To IEC 60228 Class 1 & VDE 0295 Class 1
Most of the silicone insulated cables on the following page are available from stock in standard pack sizes of 100m or 500m. For conductor sizes above 10mm2 the cable can be cut to the length you require. Other voltages, strandings and approvals available on request. Construction - SiF cables
FS
FS cables
cables
FS
FS cables
Fine tinned copper wire strands, class 5, silicone insulation. Part No.
mm²
Weight kg/km
O/D mm
Part No.
mm²
Weight kg/km
451002xx
0.25
5
1.9
451350xx
35
399
10.9
451005xx
0.50
8
2.1
451500xx
50
559
12.6
451007xx
0.75
11
2.4
451700xx
70
766
14.6
451010xx
1.0
13
2.5
451950xx
95
1032
17.5
451015xx
1.5
18
2.8
451120xx
120
1285
18.7
451025xx
2.5
30
3.4
451150xx
150
1565
20.8
451040xx
4.0
48
4.2
451185xx
185
1915
23.7
451060xx
6.0
71
4.9
451240xx
240
2550
26.9
451100xx
10
120
6.7
451300xx
300
3190
30.1
451160xx
16
187
7.7
451400xx
400
4130
36.3
451250xx
25
289
9.8
451510xx
500
5210
40.3
www.fscables.com
sales@fscables.com
O/D mm
Silicone Single Cores HIGH TEMPERATURE
131
Construction - SiD Solid tinned copper wire strands, class 1, silicone insulation. Part No.
mm²
Weight kg/km
O/D mm
Part No.
mm²
Weight kg/km
O/D mm
441005xx 441007xx
0.50
7
1.8
441015xx
1.5
19
2.6
0.75
10
2.0
441025xx
2.5
31
3.2
441010xx
1.0
13
2.1
441040xx
4.0
48
3.7
441060xx
6.0
68
4.2
SiD
Construction - SiF-GL Fine tinned copper wire strands, class 5, silicone insulation. Impregnated glass fibre braid. Various colours. Part No.
mm²
Weight kg/km
O/D mm
Part No.
mm²
46100204 46100504
Weight kg/km
O/D mm
0.25
8
2.4
46106004
0.50
13
3.4
46110004
6.0
80
6.2
10
130
461007xx
0.75
16
3.6
8.2
46116004
16
200
461010xx
1.0
19
9.6
3.8
46125004
25
310
12.0
461015xx
1.5
461025xx
2.5
24
4.3
46135004
35
420
13.5
36
5.0
46150004
50
580
46104004
4.0
15.5
55
5.6
46170004
70
790
18.0
46195004
95
1070
20.0
Construction - SiF-HT Flexible tinned copper wire strands, class 5, silicone high voltage insulation. Part No.
mm²
Volts kV
O/D mm
SiF-GL
Colour
45201000
1.0
7.5
5.0
Red
45501004
1.0
10
7.0
White
Construction - SiF-G-Si-HT
Part No.
mm²
FS
FS
FS
cables
FS
FS
FS
FS
FS
Volts kV
O/D mm
Colour
45601000
1.0
16
8.0
Blue
45601500
1.5
16
8.5
Blue
cables
silicone sheath.
cables
Flexible tinned copper wire strands, class 5, silicone high voltage insulation, glass fibre braid, blue
cables
To show the colour required please replace xx in the part number with: 04
White
08
Orange
Blue
05
Grey
09
Yellow
02
Brown
06
Violet
10
Green
03
Red
07
Pink
99
Green/Yellow
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
Black
01
cables
00
cables
132
HIGH TEMPERATURE Silicone Multicores
Silicone SiHF, SiHFP, SiHF-C-Si Multicores N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Silicone insulated and sheathed multicore cables offer electrical engineers and specifiers a superb range of options. Ideally suited to high or low temperature applications, these cables will work between -50°C and +180°C. When exposed to fire they produce minimal smoke or fumes and can be used to wire public buildings. Options include a galvanised steel wire braid for mechanical protection or a tinned copper wire braid for screening against EMI. Applications within industry include plastic forming and moulding, packaging, food processing, refrigeration, furnaces and lighting.
Technical Information
47101503
Voltage Rating:
Working
300/500V
Test
3000V
Temperature Rating:
Flexing
-25°C to +180°C
Static
-50°C to +180°C
Bending Radius SiHF:
Flexing
15 x cable diameter
Static
7.5 x cable diameter
Braided Cables:
Flexing
20 x cable diameter
Static
10 x cable diameter
Current Rating:
Refer to IEE Regs Table 4F2A&B and 4F3A&B
Conductor Stranding:
To IEC 60228 Class 5 & VDE 0295 Class 5
Construction - SiHF Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone rubber outer sheath. (Some sizes available with black or white sheaths or an overall glass fibre braid).
cables
FS
FS cables
cables
FS
Part No.
Cores x mm²
O/D mm
Part No.
Cores x mm²
O/D mm
47100702 47100703
2 x 0.75*
6.3
3 x 0.75*
7.0
47100704
4 x 0.75
7.7
47100705
5 x 0.75
8.5
47101002
2 x 1.0
7.0
47101003
3 x 1.0*
7.5
47101004
4 x 1.0
8.0
47101005
5 x 1.0
9.0
47101006
6 x 1.0
10.5
47101007
7 x 1.0
10.5
47101502
2 x 1.5
8.0
47101503
3 x 1.5*
8.5
47101504
4 x 1.5
9.0
47101505
5 x 1.5
10.0
47101506
6 x 1.5
10.5
47101507
7 x 1.5
10.5
47101508
8 x 1.5
12.0
47101510
10 x 1.5
14.5
47101512
12 x 1.5
16.0
47101516
16 x 1.5
19.5
47101518
18 x 1.5
20.0
47101520 47101524 47102502 47102503 47102504 47102505 47102507 47102512 47104002 47104003 47104004 47104005 47104007 47106002 47106003 47106004 47106005 47106007 47110004 47116004 47125004 47135004
20 x 1.5 24 x 1.5 2 x 2.5 3 x 2.5* 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0 2 x 6.0 3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0 4 x 10 4 x 16 4 x 25 4 x 35
21.0 23.0 9.5 10.5 11.5 13.0 14.0 19.0 11.0 11.5 13.0 14.5 16.0 12.0 13.0 14.0 16.0 17.5 20.0 22.0 28.0 30.2
* Also available from stock with a black or white sheath
FS cables
www.fscables.com
sales@fscables.com
133
Silicone Multicores HIGH TEMPERATURE Construction - SiHFP Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone rubber sheath. Glass fibre tape with an overall galvanised steel wire braid. Part No.
Steel Braid Armour 48100702 48100703 48100704 48100705 48100706 48100707 48101002 48101003 48101004 48101005 48101006 48101007 48101502 48101503 48101504 48101505 48101506 48101507 48101508 48101510 48101512 48101516
Cores x mm²
O/D mm
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 6 x 0.75 7 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 6 x 1.0 7 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 6 x 1.5 7 x 1.5 8 x 1.5 10 x 1.5 12 x 1.5 16 x 1.5
8.0 8.5 9.5 10.0 11.0 11.0 8.5 9.0 10.0 10.5 11.5 11.5 9.0 9.5 11.0 12.0 13.0 13.0 14.5 16.0 17.5 21.0
Part No.
Cores x mm²
O/D mm
48101518
18 x 1.5
21.5
48101520
20 x 1.5
22.5
48101524
24 x 1.5
24.5
48102502
2 x 2.5
11.0
48102503
3 x 2.5
12.0
48102504
4 x 2.5
13.0
48102505
5 x 2.5
14.5
48102507
7 x 2.5
15.5
48102512
12 x 2.5
20.5
48104002
2 x 4.0
12.5
48104003
3 x 4.0
13.0
48104004
4 x 4.0
14.5
48104005
5 x 4.0
16.0
48104007
7 x 4.0
17.5
48106002
2 x 6.0
13.5
48106003
3 x 6.0
14.5
48106004
4 x 6.0
15.5
48106005
5 x 6.0
17.5
48106007
7 x 6.0
19.0
48110004
4 x 10
21.5
48116004
4 x 16
23.5
48125004
4 x 25
30.0
48102504E
Construction - SiHF-C-Si Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone
Cores x mm²
O/D mm
Copper Braid Screen
FS
Part No.
Cores x mm²
O/D mm
49101502
2 x 1.5
10.6
49100702
2 x 0.75
9.1
49101503
3 x 1.5
11.0
49100703
3 x 0.75
9.5
49101504
4 x 1.5
11.9
49100704
4 x 0.75
10.1
49101505
5 x 1.5
13.2
49100705
5 x 0.75
10.7
49101507
7 x 1.5
14.2 cables
49100707
7 x 0.75
11.6
49101512
12 x 1.5
18.0
49100712
12 x 0.75
14.8
49102502
2 x 2.5
12.0
49101002
2x1
9.4
49102503
3 x 2.5
12.9
49101003
3x1
9.7
49102504
4 x 2.5
14.2
49101004
4x1
10.3
49102505
5 x 2.5
15.4
49101005
5x1
11.2
49102507
7 x 2.5
16.8
49101007
7x1
11.9
cables
FS
FS
FS
cables
cables
Fax : 01727 840 842
FS
FS
cables
Tel: 01727 840 841
FS
FS
cables
Part No.
cables
rubber inner sheath or polyester tape. Tinned copper wire braid. Reddish brown silicone rubber sheath.
cables
134
HIGH TEMPERATURE PTFE Single Cores
PTFE Single Cores BSXLPE/Cu/LSHF 3G 210 N2XCH-FE180/E90: Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV These cables are manufactured to BS 3G 210 and operate up to +200°C or +250°C short term with silver plated copper conductors. Nickel plated conductor versions to work up to +260°C are available to special order. Other standards available include American Mil, VDE, DIN and Lloyds. PTFE is a remarkable material. It is unaffected by most oils, fuels and fluids. The high temperature range makes it resistant to damage from heat sources such as soldering irons or components. Multicore and screened or braid armoured versions can also be manufactured in many sizes and styles. Please note due to the manufacturing process this cable may be supplied in multiple lengths on a reel. For example 100m may be made up of two or more lengths.
Technical Information Voltage Rating:
BSG31819B01
Working
Type A
300V
Type B
600V
Test: 3400V
Type C
1000V
Test: 5000V
Short term
+250°C
Temperature Rating:
Static
-55°C to +200°C
Bending Radius:
Static
6 x cable diameter
Conductor Material:
Test: 2500V
Silver plated copper
Manufactured to BS 3G 210. See page 131 for colour code table. Part No.
cables
FS
BSG31419C04
FS cables
cables
FS
FS cables
AWG
Stranding mm
CSA mm2
Voltage Grade
Weight kg/km
min
O/D mm max
BSG33007Axx
30
7/0.10
0.056
A
1.1
0.50
BSG32807Axx
28
7/0.12
0.089
A
1.4
0.56
0.65 0.71
BSG32807Bxx
28
7/0.12
0.089
B
2.1
0.76
0.96 0.80
BSG32607Axx
26
7/0.15
0.14
A
1.7
0.65
BSG32607Bxx
26
7/0.15
0.14
B
3.09
0.85
1.05
BSG32407Axx
24
7/0.20
0.22
A
3.04
0.80
0.95
BSG32407Bxx
24
7/0.20
0.22
B
3.89
1.00
1.20
BSG32407Cxx
24
7/0.20
0.22
C
4.64
1.26
1.52
BSG32219Axx
22
19/0.15
0.35
A
4.41
0.95
1.10
BSG32219Bxx
22
19/0.15
0.35
B
5.44
1.15
1.35
BSG32219Cxx
22
19/0.15
0.35
C
6.43
1.41
1.67
BSG32019Axx
20
19/0.20
0.61
A
7.19
1.20
1.35
BSG32019Bxx
20
19/0.20
0.61
B
8.43
1.40
1.60
BSG32019Cxx
20
19/0.20
0.61
C
9.08
1.66
1.92
BSG31819Bxx
18
19/0.25
0.96
B
12.1
1.65
1.85
BSG31819Cxx
18
19/0.25
0.96
C
14.3
1.91
2.17
BSG31619Cxx
16
19/0.30
1.23
C
16.5
2.16
2.46
BSG31419Cxx
14
19/0.36
1.94
C
23.9
2.34
2.74
BSG31219Cxx
12
19/0.45
3.08
C
38.5
2.91
3.31
BSG31037Cxx
10
37/0.40
4.65
C
56
3.46
3.86
www.fscables.com
sales@fscables.com
135
P-Temp 260 HIGH TEMPERATURE P-Temp 260 P-Temp-260 cables are designed to operate at conductor temperatures up to +260°C. The PTFE insulation is covered by a layer of mica that is protected from abrasion or mechanical damage by an impregnated and varnished glass fibre braid. The cable is also capable of withstanding higher temperatures for short periods. This is a direct alternative to In-Temp 250 that used to be manufactured by BICC.
76010000
The fine stranded nickel plated copper conductor provides flexibility during installation and routing with substantially improved high temperature performance over tinned or plain copper. Multicore versions can be made to your requirements normally with stainless steel or glass fibre braids. Other types of PTFE insulated wires are also available with tinned, nickel, or silver plated conductors. Please ask for details.
Construction
Technical Information
Fine nickel plated copper wire strands
Voltage Rating:
Working 0.6/1kV Test 5000V
to IEC 60228 Class 5 or finer. White PTFE insulation. Mica tape, impregnated
Temperature Rating:
Static -55°C to +260°C
and varnished glass fibre braid. Standard
Bending Radius:
Static 10 x cable diameter
colour white, other colours to special
Conductor Stranding:
To IEC 60228 class 5 flexible or finer
order.
Part No.
CSA mm2
Stranding x mm
Weight kg/km
O/D mm
Current amps*
76001000
1.0
32 x 0.2
22
3.2
25
76001500
1.5
30 x 0.25
30
3.6
40
76002500
2.5
50 x 0.25
39
3.9
54
76004000
4.0
56 x 0.3
56
4.7
74
76006000
6.0
84 x 0.3
80
6.1
98
76010000
10
133 x 0.3
120
6.9
135
76016000
16
126 x 0.4
193
8.7
180
76025000
25
196 x 0.4
287
10.2
240
cables
FS
FS
FS
cables
FS
cables
cables
cables
Up to 25mm2 held in stock.
FS
cables
*Current rating at +80°C ambient for conductor temperature of +250°C.
FS
We also hold stocks of some sizes of Unipren, Uniefglas, Uniminyvin, Uninyvin and Unitersil. Please ask for details.
Tel: 01727 840 841
Fax : 01727 840 842
FS
cables
FS cables
136
HIGH TEMPERATURE G-Temp 600
G-Temp 600 N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Pure nickel conductors offer excellent high temperature performance. The conductor can withstand temperatures up to +750°C. The high temperature glass insulation enables the nickel conductor to operate continuously at +600°C and for short periods up to +750°C. Applications include furnaces, ovens, kilns and other extremely high temperature environments. These cables can also be supplied in multicore versions with overall glass fibre or stainless steel braids for quantities as low as 100m. Higher voltages are available by special order. These include a mica tape in the cable construction. Please call if you have a specific requirement.
Technical Information
Construction Pure nickel strands, double glass yarn lapped,
Voltage Rating:
Working 250V
impregnated, glass braided, double silicone varnished,
Temperature Rating:
Continuous +600°C Intermittent +750°C
colour natural/white. Part No.
78504056
Nominal CSA mm2
Stranding x mm
Lug Type
Weight kg/km
O/D mm
Current ratings in Amps at +30°C Ambient. Conductor Temp. +180°C +200° +250°C
78500516
0.50
16/0.2
A
9
2.0
5
6
78500724
0.75
24/0.2
A
11
2.3
6
7
7.5 9
78501032
1.0
32/0.2
A
16
2.5
9
9
10
78501530
1.5
30/0.25
B
22
2.7
15
16
17
78502550
2.5
50/0.25
B
32
3.3
21
22
23
78504056
4.0
56/0.3
C
46
3.9
26
28
29
78506084
6.0
84/0.3
C
59
5.2
31
33
34
Nickel Crimp Lugs cables
FS
Copper is not suitable for crimp lugs at very high temperatures due to its greater expansion rate. This can result in nickel conductors simply dropping out. We are able to offer high temperature stable crimp lugs that will work at over +800ºC suitable for use on FSC G-Temp-600.
FS cables
Part No.
Lug Type
Conductor Size Min Max
Stud Size
Max Length
Max Width
LUGN02/1/4
A
0.25mm2
1.0mm2
4mm
14.8
6.8
LUGN10/2/4
B
1.0mm2
2.5mm2
4mm
16.4
8.3
LUGN20/6/4
C
2.5mm2
6.0mm2
4mm
20.0
9.9
cables
FS
FS cables
www.fscables.com
sales@fscables.com
137
318*TQ Heat Resistant Flex HIGH TEMPERATURE 318*TQ Heat Resistant Flex TQ flex is suitable for use on heat resistant applications ranging from lighting to central heating systems and immersion heaters. With colour coloured cores and rated at 85째C this cable is ideal as a power supply lead or a control cable where ambient temperatures exceed the working range of standard PVC cables. The EPR insulation and CSP jacket result in a highly flexible yet tough cable.
Construction
Technical Information
Stranded copper conductors to IEC
Voltage Rating:
300/500V
60228 Class 5, ethylene propylene
Conductor Stranding:
Stranded. IEC 60228 class 5
rubber (EPR, T) insulation colour coded.
Temperature Rating:
-20째c to +85째c
Cores laid up, white chlorosulphonated
Bending Radius:
6 x overall diameter
57101504TQ
polyethylene (CSP, Q) jacket Normally packed on 50m or 100m reels longer lengths may be available. Part No.
Cores x mm2
Weight kg/km
O/D mm
57100702TQ
2 x 0.75
65
6.6
57100703TQ
3 x 0.75
80
7.3
57100704TQ
4 x 0.75
95
7.8
80
7.3
95
7.8
57101004TQ
4 x 1.0
115
8.3
57101502TQ
2 x 1.5
120
8.8
57101503TQ
3 x 1.5
140
9.5
57101504TQ
4 x 1.5
175
10.5
57102502TQ
2 x 2.5
170
10.3
57102503TQ
3 x 2.5
200
11.0
57102504TQ
4 x 2.5
250
12.2
FS
FS
cables
2 x 1.0 3 x 1.0
cables
57101002TQ 57101003TQ
Motorised Valve Extension Cable Ideal for extending the cables on motorised valves on heating systems. Using heat resistant 90째C PVC these cables make connecting up zoned systems simple. The colour code emulates the one used on popular motorised valves.
FS
cables
Construction
FS cables
Stranded copper conductors IEC 60228 class 5, PVC insulation, colour coded. Cores laid up, black heat resistant PVC jacket. Weight kg/km
O/D mm
10000706MV
6 x 0.75
81
6.9
Colour Code: Blue
Brown
Grey
Orange
FS
FS
FS
FS
cables
Cores x mm2
cables
Part No.
Green/Yellow White
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
138
THERMOCOUPLE Thermocouple Cables
Thermocouple Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Thermocouple cables are used to carry a signal from a thermocouple probe to the temperature measuring unit and are made up of a screened positive and negative (orscreening leg) of different metals whichinare same similar those the Fire resistant power cablesconductor provide EMI and circuit integrity thethe event of aorfire. Theyasare idealinfor thermocouple probe. applications such as fire pumps and ventilation systems in office blocks where electrical interference needs keeping to a minimum duringreferred normal to operation and services must be maintained evacuation during a fire situation. The cables meet While commonly as thermocouple cables, most cables are infor fact ‘extension’ or ‘compensating’ cables. IEC 60331 and are fire resistant for 3 hours at 750°C. Extension cables are manufactured with the same metals as the thermocouple probe. Due to the expense of extension cables, compensating often usedpart in their place provideon accurate E30 System integrity cables cables are to DIN 4102 12 are alsoand available request.results over a more limited operating range. As with any other instrumentation or measuring application it can be beneficial to have multiple numbers of pairs. Triples are also available to meet specialist applications. Interference (EMI) is also something to consider and screening, either individually around each pair or collectively around a multi pair is an option. If the cable is likely to suffer mechanical damage or be buried in the ground armouring (SWA) is also available. Cables installed in sensitive locations such as power stations Low Smoke Halogen Free thermocouple cables may be required.
International Colour Codes for Thermocouple Cable Insulation
Cable Type
EUROPEAN BS 4937 Part 30
BRITISH BS 1843
AMERICAN ANSI MC96.1
GERMAN DIN 43710.4
Extension Cables
cables
FS
FS
KX
+ –
+ –
+ –
+ –
JX
+ –
+ –
+ –
+ –
TX
+ –
+ –
+ –
+ –
EX
+ –
+ –
+ –
+ –
NX
+ –
+ –
+ –
+ –
+ –
+ –
+ –
+ –
+ –
+ –
+ –
+ –
Compensating Cables
cables
KCB
Compensation for Type K (was Vx)
RCA/SCA cables
FS
FS cables
Compensation for Type R or S
www.fscables.com
sales@fscables.com
139
Thermocouple Cables THERMOCOUPLE Part No.
Conductor Type
No. of Pairs
Conductor Size
Screening Type
Insulation Material
Sheath Material
1 1 1 1 1 1 1 1
7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm
Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened
PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC
KCB KCB KCB KCB KCB KCB KCB KCB
1 1 1 1 1 1 1 1
7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm
Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened
PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC
TKXO0201 TKXU0201 TKXO0401 TKXU0401 TKXO0502H TKXO0701 TKXU0701 TKXO1501 TKXU1501
KX KX KX KX KX KX KX KX KX
1 1 1 1 1 1 1 1 1
7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 16/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm
Overall Foil Unscreened Overall Foil Unscreened Overall Braid Overall Foil Unscreened Overall Foil Unscreened
PVC PVC PVC PVC LSHF PVC PVC PVC PVC
PVC PVC PVC PVC LSHF PVC PVC PVC PVC
TNXO0201 TNXU0201 TNXO0401 TNXU0401 TNXO0701 TNXU0701 TNXO1501 TNXU1501
NX NX NX NX NX NX NX NX
1 1 1 1 1 1 1 1
7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm
Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened
PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC
TRCO0201 TRCU0201 TRCO0401 TRCU0401 TRCO0701 TRCU0701 TRCO1501 TRCU1501
RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA
1 1 1 1 1 1 1 1
7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm
Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened
PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC
TTXO0201 TTXU0201 TTXO0401 TTXU0401 TTXO0701 TTXU0701 TTXO1501 TTXU1501
TX TX TX TX TX TX TX TX
1 1 1 1 1 1 1 1
7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm
Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened
Screened & Unscreened Single Pairs TJXO0201 JX TJXU0201 JX TJXO0401 JX TJXU0401 JX TJXO0701 JX TJXU0701 JX TJXO1501 JX TJXU1501 JX TKCO0201 TKCU0201 TKCO0401 TKCU0401 TKCO0701 TKCU0701 TKCO1501 TKCU1501
PVC
PVC cables
FS
FS
cables
FS
PVC PVC cables PVC PVC PVC PVC PVC PVC
FS
cables
PVC PVC PVC PVC PVC PVC
FS
cables
Fax : 01727 840 842
FS
cables
Tel: 01727 840 841
cables
*Please note all the above cables are European Colour Coded.
FS
FS cables
140
THERMOCOUPLE Thermocouple Cables
Individually and Collectively Foil Screened Multipairs, PVC, Armoured & Unarmoured Construction - Unarmoured
Construction - Armoured
Conductors insulated in PVC, cores laid up to form a pair,
Conductors insulated in PVC, cores laid up to form a pair, each pair
each pair individually foil screened with drain wire, pairs laid
individually foil screened with drain wire, pairs laid up, overall foil screen
up, overall foil screen with drain wire, PVC outer sheath.
with drain wire, PVC bedding, steel wire armour, PVC outer sheath.
TTXO0505A
cables
FS
FS cables
cables
FS
FS cables
Part No. Unarmoured
Conductor Type
No. of Pairs
Conductor Size mm2
Screening Type
Insulation Material
Sheath Material
Part No. Armoured
TJXI0502 TJXI0504 TJXI0506 TJXI0512 TJXI0516 TJXI0520 TJXI0524 TJXI0702 TJXI0704 TJXI0706 TJXI0712 TJXI0716 TJXI0720 TJXI0724
JX JX JX JX JX JX JX JX JX JX JX JX JX JX
2 4 6 12 16 20 24 2 4 6 12 16 20 24
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75
Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
TJXI0502A TJXI0504A TJXI0506A TJXI0512A TJXI0516A TJXI0520A TJXI0524A TJXI0702A TJXI0704A TJXI0706A TJXI0712A TJXI0716A TJXI0720A TJXI0724A
TKXI0502 TKXI0504 TKXI0506 TKXI0512 TKXI0516 TKXI0520 TKXI0524 TKXI0702 TKXI0704 TKXI0706 TKXI0712 TKXI0716 TKXI0720 TKXI0724
KX KX KX KX KX KX KX KX KX KX KX KX KX KX
2 4 6 12 16 20 24 2 4 6 12 16 20 24
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75
Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
TKXI0502A TKXI0504A TKXI0506A TKXI0512A TKXI0516A TKXI0520A TKXI0524A TKXI0702A TKXI0704A TKXI0706A TKXI0712A TKXI0716A TKXI0720A TKXI0724A
TKCI0502 TKCI0504 TKCI0506 TKCI0512 TKCI0516 TKCI0520 TKCI0524 TKCI0702 TKCI0704 TKCI0706 TKCI0712 TKCI0716 TKCI0720 TKCI0724
KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB
2 4 6 12 16 20 24 2 4 6 12 16 20 24
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75
Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
TKCI0502A TKCI0504A TKCI0506A TKCI0512A TKCI0516A TKCI0520A TKCI0524A TKCI0702A TKCI0704A TKCI0706A TKCI0712A TKCI0716A TKCI0720A TKCI0724A
TNXI0502 TNXI0504 TNXI0506 TNXI0512 TNXI0516 TNXI0520 TNXI0524 TNXI0702 TNXI0704 TNXI0706 TNXI0712 TNXI0716 TNXI0720 TNXI0724
NX NX NX NX NX NX NX NX NX NX NX NX NX NX
2 4 6 12 16 20 24 2 4 6 12 16 20 24
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75
Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
TNXI0502A TNXI0504A TNXI0506A TNXI0512A TNXI0516A TNXI0520A TNXI0524A TNXI0702A TNXI0704A TNXI0706A TNXI0712A TNXI0716A TNXI0720A TNXI0724A
www.fscables.com
sales@fscables.com
141
Thermocouple Cables THERMOCOUPLE Part No. Unarmoured
Conductor Type
No. of Pairs
Conductor Size mm2
Screening Type
Insulation Material
Sheath Material
Part No. Armoured
TRCI0502 TRCI0504 TRCI0506 TRCI0512 TRCI0516 TRCI0520 TRCI0524 TRCI0702 TRCI0704 TRCI0706 TRCI0712 TRCI0716 TRCI0720 TRCI0724
RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA
2 4 6 12 16 20 24 2 4 6 12 16 20 24
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75
Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
TRCI0502A TRCI0504A TRCI0506A TRCI0512A TRCI0516A TRCI0520A TRCI0524A TRCI0702A TRCI0704A TRCI0706A TRCI0712A TRCI0716A TRCI0720A TRCI0724A
TTXI0502 TTXI0504 TTXI0506 TTXI0512 TTXI0516 TTXI0520 TTXI0524 TTXI0702 TTXI0704 TTXI0706 TTXI0712 TTXI0716 TTXI0720 TTXI0724
TX TX TX TX TX TX TX TX TX TX TX TX TX TX
2 4 6 12 16 20 24 2 4 6 12 16 20 24
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75
Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
TTXI0502A TTXI0504A TTXI0506A TTXI0512A TTXI0516A TTXI0520A TTXI0524A TTXI0702A TTXI0704A TTXI0706A TTXI0712A TTXI0716A TTXI0720A TTXI0724A
*For Halogen Free versions please add an H to the end of the part number. These will generally be supplied with XLPE insulation and a LSHF sheath. Please note all the above cables are European Colour Coded
Screened Single pairs, LSHF Fire Resistant, Armoured & Unarmoured Construction - Unarmoured
Construction - Armoured
Conductors stranded and mica taped, XLPE insulated, cores
Conductors stranded and mica taped, XLPE insulated, cores twisted to form a pair, overall foil screen with drain wire, LSHF bedding, steel wire armour, LSHF outer sheath.
twisted to form a pair, overall foil screen with drain wire,
Conductor Type
No. of Pairs
Conductor Size mm2
Screening Type
Insulation Material
TJXO0501M TJXO0701M
JX JX
1 1
0.5 0.75
Overall Foil Overall Foil
XLPE XLPE
TKCO0501M TKCO0701M
KCB KCB
1 1
0.5 0.75
Overall Foil Overall Foil
XLPE XLPE
TKXO0501M TKXO0701M
KX KX
1 1
0.5 0.75
Overall Foil Overall Foil
XLPE XLPE
TNXO0501M TNXO0701M
NX NX
1 1
0.5 0.75
Overall Foil Overall Foil
TRCO0501M TRCO0701M
RCA/SCA RCA/SCA
1 1
0.5 0.75
TTXO0501M TTXO0701M
TX TX
1 1
0.5 0.75
FS
Sheath Material
Part No. Armoured
LSHF LSHF
TJXO0501AM TJXO0701AM
LSHF LSHF
TKCO0501AM TKCO0701AM
FS
cables LSHF
FS
LSHF
cables TKXO0501AM TKXO0701AM
XLPE XLPE
LSHF LSHF
TNXO0501AM TNXO0701AM
Overall Foil Overall Foil
XLPE XLPE
LSHF LSHF
TRCO0501AM TRCO0701AM
Overall Foil Overall Foil
XLPE XLPE
FS
LSHF LSHF
TTXO0501AM TTXO0701AM
FS
cables
FS
cables
Fax : 01727 840 842
cables
Tel: 01727 840 841
FS
cables
Part No. Unarmoured
cables
LSHF outer sheath.
FS cables
142
SPIRAL Spiral Cables
Spiral Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV
FSC offers both signal and power versions of retractable spiral cables. The variations in conductor size, insulation and sheath materials are enormous. Having decided on the conductor size and the number of cores it is important to choose the insulation and sheath materials most suitable for the task. The retracted length of the spiral can be made to your requirements up to 5m. Although once popular, PVC is now giving way to polyurethane as a sheathing material which has a much better memory. Rubber is still popular with hytral used for the highest performance cables. The sizes and types shown on the page opposite are a small selection of the spiral cables offered. There are many other sheathing, insulation materials and voltage ratings as well as screened versions available. Please call with your exact requirement. These cables are manufactured to order, to meet your needs precisely. You can specify tail lengths (the straights at either end). The standard length is at least 150mm and they can be supplied in line or at right angles to the coil. Delivery is normally around 10 working days but please check when ordering. Many other core combinations are available. Please call to discuss your requirements.
Spiral Cable
Construction - PVC Spiral Cable
Technical Information
Fine copper wire strands. PVC insulation, colour coded cores, twisted together, PVC jacket.
Voltage Rating: Working 300/500V Temperature Rating: -5°C to +70°C Approximate Extension Ratio: 3.5:1
Part No.
PVC Spirals 88200702 88200703 88200704 88200705 88201002
cables
FS
cables
cables
FS
FS cables
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.0
Part No.
Cores x mm²
Part No.
Cores x mm²
88201003 88201004 88201005 88201502 88201503 88201504
3 x 1.0 4 x 1.0 5 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5
88201505 88202502 88202503 88202504 88202505
5 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5
Construction: PUR Screened Spiral Cable
Technical Information
Fine copper wire strands of class 5 or 6. TPE insulation, colour coded cores, twisted together, overall tinned copper wire braid, PUR jacket.
Working ≤0.25mm² 100V ≥ 0.5mm² 300V Temperature Rating: -25°C to +80°C Approximate Extension Ratio: 4:1
Part No.
FS
Cores x mm²
Cores x mm²
PUR Screened Spirals 88300102 2 x 0.14 88300103 3 x 0.14 88300104 4 x 0.14 88300105 5 x 0.14 88300106 6 x 0.14 88300107 7 x 0.14 88300108 8 x 0.14 88300112 12 x 0.14 88300118 18 x 0.14 88300125 25 x 0.14
Voltage Rating:
Part No.
Cores x mm²
Part No.
Cores x mm²
88300202 88300203 88300204 88300205 88300206 88300207 88300208 88300212 88300218 88300225
2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 6 x 0.25 7 x 0.25 8 x 0.25 12 x 0.25 18 x 0.25 25 x 0.25
88300503 88300504 88300505 88300506 88300507 88300508 88300512 88300518 88300525
3 x 0.5 4 x 0.5 5 x 0.5 6 x 0.5 7 x 0.5 8 x 0.5 12 x 0.5 18 x 0.5 25 x 0.5
www.fscables.com
sales@fscables.com
143
Spiral Cables SPIRAL Construction: PUR Spiral Cable
Technical Information
Fine copper wire strands of class 5 or 6. TPE or EPR insulation, colour coded cores, twisted together, PUR jacket.
Voltage Rating: Temperature Rating: Approximate Extension Ratio:
Part No.
Cores x mm²
PUR Unscreened Spirals 88100102 2 x 0.14 88100103 3 x 0.14 88100104 4 x 0.14 88100105 5 x 0.14 88100106 6 x 0.14 88100107 7 x 0.14 88100108 8 x 0.14 88100110 10 x 0.14 88100112 12 x 0.14 88100116 16 x 0.14 88100125 25 x 0.14 88100202 2 x 0.25 88100203 3 x 0.25 88100204 4 x 0.25
Part No.
Cores x mm²
88100205 88100206 88100207 88100208 88100210 88100212 88100216 88100225 88100502 88100503 88100504 88100505 88100506 88100507 88100508
5 x 0.25 6 x 0.25 7 x 0.25 8 x 0.25 10 x 0.25 12 x 0.25 16 x 0.25 25 x 0.25 2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 6 x 0.5 7 x 0.5 8 x 0.5
Part No.
Cores x mm²
88100510 88100512 88100516 88100525 88100702 88100703 88100704 88100705 88101002 88101003 88101004 88101005 88101007 88101012 88101502
Part No.
10 x 0.5 12 x 0.5 16 x 0.5 25 x 0.5 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 2 x 1.5
88101503 88101504 88101505 88101507 88101512 88102503 88102504 88102505 88104004 88104005 88106004
Construction: Rubber TPE Spiral Cable
Technical Information
Fine copper wire strands of class 5. Special PVC insulation, colour coded cores, twisted together, black TPE synthetic rubber jacket.
Voltage Rating: Temperature Rating: Approximate Extension Ratio:
Part No.
Cores x mm²
3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 3 x 2.5 4 x 2.5 5 x 2.5 4 x 4.0 5 x 4.0 4 x 6.0
Part No.
Cores x mm²
Part No.
Cores x mm²
88001005 88001007 88001010 88001015 88001502 88001503 88001504 88001505 88001507 88001510 88001515
5 x 1.0 7 x 1.0 10 x 1.0 15 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 10 x 1.5 15 x 1.5
88002502 88002503 88002504 88002505 88002507 88004003 88004004 88004005 88006003 88006004
2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 3 x 4.0 4 x 4.0 5 x 4.0 3 x 6.0 4 x 6.0
FS
LE LC
ST
FS
cables
2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 10 x 0.75 15 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0
Cores x mm²
Working 300/500V -15°C to +80°C 5:1
cables
Rubber TPE Spirals 88000702 88000703 88000704 88000705 88000707 88000710 88000715 88001002 88001003 88001004
Working 300/500V -25°C to +85°C 4:1
FS
ST cables
FS
FS
FS
FS
FS
cables
DS
Length of ST straight tail
LE Length extended
DS Diameter of spiral
Length of tail RA at right angles
LC Length closed
DC
Tel: 01727 840 841
Fax : 01727 840 842
Diameter of cable
cables
cables
RA DC
cables
RA
cables
144
GLANDS Plastic & Brass Industrial
Industrial Glands XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV
FSC offers a range of high quality industrial cable glands manufactured in nylon and metal to meet industry requirements. Metal glands are available in a plain brass or with nickel plating. All the glands have at least one rubber seal to provide environmental protection and an IP (Ingress Protection) rating. To achieve the IP rating shown an additional washer may be required if the enclosure or panel is not threaded. If you are not sure please ask at time of enquiry. We can also supply gland kits complete with accessories, please add a K to the end of the part number. Aluminium glands for terminating AWA type armours and stainless steel glands for specialist applications are also available. A2 nickel plated brass glands for unarmoured cables IP68 rated indoor/outdoor glands with a single rubber seal on the cable sheath. -60°C to +150°C. Sometimes referred to as stuffing glands they are ideal for unarmoured or flexible cables. Part No.
A2
GA2M20SSN GA2M20SN GA2M20N GA2M25N GA2M32N GA2M40N GA2M50SN GA2M50N GA2M63SN GA2M63N GA2M75SN GA2M75N GA2M90N GA2M100N GA2M115N GA2M130N
Description
Thread ISO (mm)
Cable O/D Range (mm)
A2 20S/16 A2 20S A2 20 A2 25 A2 32 A2 40 A2 50S A2 50 A2 63S A2 63 A2 75S A2 75 A2 90 A2 100 A2 115 A2 130
20 20 20 25 32 40 50 50 63 63 75 75 90 100 115 130
3.1 - 8.7 6.1 - 11.7 6.5 - 14.0 11.1 - 20.0 17.0 - 26.3 23.5 - 32.2 31.0 - 38.2 35.6 - 44.1 41.5 - 50.0 47.2 - 56.0 54.0 - 62.0 61.1 - 68.0 66.6 - 79.4 76.0 - 91.0 86.0 - 98.0 97.0 - 115.0
Steel Locknut
GLSM20 GLSM20 GLSM20 GLSM25 GLSM32 GLSM40 GLSM50 GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130
CW nickel plated brass glands for SWA armoured cables Ideal for anchoring the steel wire armour (SWA) on power, data and instrumentation cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on the outer sheath of the cable. -60°C to +150°C.
CW cables
FS
FS cables
cables
FS
FS cables
Part No.
GCWM20SSN GCWM20SN GCWM20N GCWM25SN GCWM25N GCWM32N GCWM40N GCWM50SN GCWM50N GCWM63SN GCWM63N GCWM75S GCWM75N GCWM90N GCWM100N GCWM115N GCWM130N
Description
Thread ISO (mm)
Cable Bedding Diameter
Cable O/D Range (mm)
Steel Locknut
CW 20S/16 CW 20S CW 20 CW 25S CW 25 CW 32 CW 40 CW 50S CW 50 CW 63S CW 63 CW 75S CW 75 CW 90 CW 100 CW 115 CW 130
20 20 20 25 25 32 40 50 50 63 63 75 75 90 100 115 130
8.7 11.7 14.0 19.9 20.0 26.3 32.2 38.2 44.1 50.0 56.0 62.0 68.0 80.0 91.0 98.0 115.0
6.1 - 11.5 9.5 - 15.9 12.5 - 20.9 14.0 - 22.0 18.2 - 26.2 23.7 - 33.9 27.9 - 40.4 35.2 - 46.7 40.4 - 53.1 45.6 - 59.4 54.6 - 65.9 59.0 - 72.1 66.7 - 78.5 76.2 - 90.4 89.1 - 101.5 101.3 - 110.3 114.0 - 123.3
GLSM20 GLSM20 GLSM20 GLSM25 GLSM25 GLSM32 GLSM40 GLSM50 GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130
www.fscables.com
sales@fscables.com
145
Plastic & Brass Industrial GLANDS Industrial Glands XLPE/Cu/LSHF Screened, Fire Resistant (IEC N2XCH-FE180/E90: 60331)
Always use a gland with a maximum size closest to the diameter of the cable so the gland only has to compress a minimal amount. Reducers, enlargers and convertors are available to alter the gland thread size. These can be supplied in metal or plastic to fit pre threaded enclosures or equipment. Adaptors are also available to change one type of thread to another. Combinations include ISO metric, NPT and PG. CX nickel plated glands for braided cables and steel tape armoured cables Designed to secure braid armours and braid screens they can also be used for steel tape armours on fibre optic and instrumentation cables. IP66 rated indoor/outdoor glands that terminate the braid or tape and provide a seal on the cable sheath. -60째C to +150째C. Part No.
Description
Thread ISO (mm)
Cable Bedding Diameter
GCXM20SSN GCXM20SN GCXM20N GCXM25SN GCXM25N GCXM32N GCXM40N GCXM50SN GCXM50N GCXM63SN GCXM63N GCXM75SN GCXM75N GCXM90N GCXM100N GCXM115N GCXM130N
CX 20S/16 CX 20S CX 20 CX 25S CX 25 CX 32 CX 40 CX 50S CX 50 CX 63S CX 63 CX 75S CX 75 CX 90 CX 100 CX 115 CX 130
20 20 20 25 25 32 40 50 50 63 63 75 75 90 100 115 130
8.7 11.7 14.0 19.9 20.0 26.3 32.2 38.2 44.1 50.0 56.0 62.0 68.0 80.0 91.0 98.0 115.0
Cable O/D Range (mm)
6.1 - 11.5 9.5 - 15.9 12.5 - 20.9 14.0 - 22.0 18.2 - 26.2 23.7 - 33.9 27.9 - 40.4 35.2 - 46.7 40.4 - 53.1 45.6 - 59.4 54.6 - 65.9 59.0 - 72.1 66.7 - 78.5 76.2 - 90.4 89.1 - 101.5 101.3 - 110.3 114.0 - 123.3
Steel Locknut
GLSM20 GLSM20 GLSM20 GLSM25 GLSM25 GLSM32 GLSM40 GLSM50 GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130
CX
E1W dual seal nickel plated brass glands for SWA armoured cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on to the inner and outer sheath of the cable. -60째C to +150째C. Part No.
6.1 -11.5 9.5 -15.9 12.5 -20.9 14.0 -22.0 18.2 -26.2 23.7 -33.9 27.9 -40.4 35.2 -46.7 40.4 -53.1 45.6 -59.4 54.6 -65.9 59.0 -72.1 66.7 -78.5 76.2 -90.4 89.1 -101.5 101.3 -110.3 114.0 -123.3
Fax : 01727 840 842
Steel Locknut
E1W
FS
FS
FS
FS
FS
FS
FS
FS
GLSM20 GLSM20 GLSM20 GLSM25 GLSM25 GLSM32 GLSM40 GLSM50cables GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130
cables
cables
cables
Tel: 01727 840 841
3.1 -8.7 6.1 -11.7 6.5 -14.0 11.1 -19.9 11.1 -20.0 17.0 -26.3 22.0 -32.2 29.5 -38.2 35.6 -44.1 40.1 -50.0 47.2 -56.0 52.8 -62.0 59.1 -68.0 66.6 -80.0 76.0 -91.0 86.0 -98.0 97.0 -115.0
Cable O/D Range (mm)
cables
20 20 20 25 25 32 40 50 50 63 63 75 75 90 100 115 130
Cable Bedding Diameter
cables
E1W 20S/16 E1W 20S E1W 20 E1W 25S E1W 25 E1W 32 E1W 40 E1W 50S E1W 50 E1W 63S E1W 63 E1W 75S E1W 75 E1W 90 E1W 100 E1W 115 E1W 130
Thread ISO (mm)
cables
GE1WM20SSN GE1WM20SN GE1WM20N GE1WM25SN GE1WM25N GE1WM32N GE1WM40N GE1WM50SN GE1WM50N GE1WM63SN GE1WM63N GE1WM75SN GE1WM75N GE1WM90N GE1WM100N GE1WM115N GE1WM130N
Description
cables
146
GLANDS Plastic & Brass Industrial
Industrial Glands XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV
If the gland type you require is not shown or you need a specialist gland for a bespoke application please contact us and we will do our best to help you. E1X dual seal nickel plated brass glands for braid armoured cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on to the inner and outer sheath of the cable. -60°C to +150°C. Part No.
E1X
Description
Thread ISO (mm)
Cable Bedding Diameter
Cable O/D Range (mm)
Steel Locknut
GE1XM20SS
E1X 20S/16
GE1XM20S
E1X 20S
20
3.1 - 8.7
6.1 - 11.5
GLSM20
20
6.1 - 11.7
9.5 - 15.9
GE1XM20
E1X 20
GLSM20
20
6.5 - 14.0
12.5 - 20.9
GLSM20
GE1XM25S
E1X 25S
25
11.1 - 19.9
14.0 - 22.0
GLSM25
GE1XM25
E1X 25
25
11.1 - 20.0
18.2 - 26.2
GLSM25
GE1XM32
E1X 32
32
17.0 - 26.3
23.7 - 33.9
GLSM32
GE1XM40
E1X 40
40
22.0 - 32.2
27.9 - 40.4
GLSM40
GE1XM50S
E1X 50S
50
29.5 - 38.2
35.2 - 46.7
GLSM50
GE1XM50
E1X 50
50
35.6 - 44.1
40.4 - 53.1
GLSM50
GE1XM63S
E1X 63S
63
40.1 - 50.0
45.6 - 59.4
GLSM63
GE1XM63
E1X 63
63
47.2 - 56.0
54.6 - 65.9
GLSM63
GE1XM75S
E1X 75S
75
52.8 - 62.0
59.0 - 72.1
GLSM75
GE1XM75
E1X 75
75
59.1 - 68.0
66.7 - 78.5
GLSM75
GE1XM90
E1X 90
90
66.6 - 80.0
76.2 - 90.4
GLSM90
GE1XM100
E1X 100
100
76.0 - 91.0
89.1 - 101.5
GLSM100
GE1XM115
E1X 115
115
86.0 - 98.0
101.3 - 110.3
GLSM115
GE1XM130
E1X 130
130
97.0 - 115.0
114.0 - 123.3
GLSM130
Nylon Cable Glands for unarmoured cablesFire Resistant (IEC N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, 60331)
IP68 rated glands which seal onto the outer sheath. Ideal for use on flexible cables and screened cables where the screen it terminated inside the enclosure. If the gland is not being used on a threaded enclosure you may require a locknut which is sold separately. -30°C to +80°C.
Nylon Gland
cables
FS
ISO Metric Thread Part No.
FS cables
cables
FS
Size
German PG Thread
Spanner Cable O/D Size Range (mm)
Locknut
Part No.
Size
Spanner Size
Cable O/D Range (mm)
Locknut
GLP07x
GNM12x
M12
15
3.0-6.5
GLNM12x
GNP07x
PG7
15
3.0-6.5
GNM16x
M16
19
5.0-10.0
GLNM16x
GNP09x
PG9
19
4.0-8.0
GLP09x
GNM20x
M20
24
6.0-12.0
GLNM20x
GNP11x
PG11
22
5.0-10.0
GLP11x
GNM25x
M25
33
9.0-17.0
GLNM25x
GNP13x
PG13
24
6.0-12.0
GLP13x
GNM32x
M32
42
18.0-25.0 GLNM32x
GNP16x
PG16
27
10.0-14.0
GLP16x
GNM40x
M40
53
22.0-32.0 GLNM40x
GNP21x
PG21
33
13.0-18.0
GLP21x
GNM50x
M50
60
30.0-38.0 GLNM50x
GNP29x
PG29
42
18.0-25.0
GLP29x
GNM63x
M63
68
34.0-42.0 GLNM63x
GNP36x
PG36
53
22.0-32.0
GLP36x
GNP42x
PG42
60
30.0-38.0
GLP42x
GNP48x
PG48
65
34.0-44.0
GLP48x
To show the colour required please replace x in the part number with:
FS cables
0
Black
3
Red
4
White
www.fscables.com
5
Grey - RAL 7001
6
Light Grey - RAL 7035
sales@fscables.com
147
Jointing Kits GLANDS Jointing Kits N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331)
???
A range of jointing kits are provided to enable the safe connection of cables either above or below ground. Suitable for use on data, signal, telephone or power cables with or without armour, the conductors are first jointed using the appropriate connector then the outer shell is put in place and filled with a two part polyurethane resin. The resin is supplied in a fully enclosed easy-mixing sachet for a simple, clean application. These joints will last for years in either fixed or permanent installations. Please note the jointing boxes below include the shells, resin and armour bonds. They do not include the conductor joints which will vary depending on the type of cable and need to be ordered separately. Crimps are also available for telephone cables and solid conductor data cables.
Part No.
Cable O/D Range (mm)
Internal Length (mm)
Internal Width (mm)
Part No.
Cable O/D Range (mm)
Internal Length (mm)
Internal Width (mm)
JK1 JK2 JK3 JK4
12 - 26 14 - 32 23 - 39 28 - 50
185 245 325 375
35 48 52 68
JK5 JK6 JK7 JK8
32 - 58 45 - 75 40 - 89 57 - 95
520 705 862 900
102 124 140 150
Crimp Lugs Crimp Lugs N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC Crimp lug for jointing two power cable conductors. Crimps are sold singularly so you need to order the correct number to suit 60331) the cable you are jointing. Armour bonds are included for jointing SWA cables.
Conductor Size mm²
1.5 2.5 4.0 6.0
Lug Part No.
Conductor Size mm²
LUC015 LUC025 LUC040 LUC060
Lug Part No.
10 16 25 35
Conductor Size mm²
LUC100 LUC160 LUC250 LUC350
50 70 95 120
Description
Max. No. Wires
Length mm
Width mm
Open Height mm
Closed Height mm
8A/1 connector 8B connector 11A connector
2 3 2
14.85 16.25 12.60
9.75 12.65 12.50
9.00 9.00 9.30
6.40 6.40 5.80
Conductor Dia. Min. & Max. mm
FS
0.4 – 0.9 0.4 – 0.9 0.4 – 0.9 cables
FS
2.10 2.10 2.06cables
FS
FS
FS
cables
cables
Fax : 01727 840 842
Max. Dia. inc Insulation mm
FS
cables
Tel: 01727 840 841
FS
cables
cables
8A/1 8B 11A
LUC500 LUC700 LUC950 LUC120
FS
Connectors for Solid Telecom Conductors Part No.
Lug Part No.
cables
148
TOOLS
Tools High quality tools needn’t cost a fortune. Designed with the operator in mind and a long service life you can be confident the FSC range of tools will do the job. Covering crimping, cutting, stripping and installation, these tools have been chosen for their ease of use and cost effectiveness. Try a single piece and if you agree that they are great value for money, enjoy the quantity discounts offered on multiple items.
YTC1
Coax Connector Tools A range of well made and competitively priced tools to crimp most types of connectors from BNC to N-Type onto various coaxial cables. Part No.
YTS1
Description
Handle Colour
YTC1
Crimp Tool 1 for RG58, RG59, RG62, RG59 Mini & PSF 1/3
Yellow
YTC2
Crimp Tool 2 for RG59, CT100, CT125
Green
YTC3
Crimp Tool 3 for RG11, RG213 & CT125 (BNC only)
Blue
YTC10
Crimp Tool 10 for Firetuf Coax Cable 387FTC5903
Blue
Part No.
Description
YTS1
Cable Stripper for RG58 & RG59
YTS2
Cable Stripper for Cat 5E & Cat 6
RJ45 Tools YTC5
Designed to crimp RJ45 connectors up to 10 pin onto solid or stranded conductors. Suitable for most popular RJ45 connectors. Part No.
Description
YTC5
Handle Colour
Crimp tool 5 for RJ45 connectors
Orange
Cable Jacket Strippers cables
FS
YCS1
A safe and quick way of scoring and stripping sheaths and jackets from SWA, LSHF or PVC mains or control cables. Blades are adjustable for depth and direction. Metal cutting parts are used to reduce wear and replacement blades are available to ensure a long service life. Part No.
Description
YCS1
FS cables
Adjustable Cable Slitter for O/D 4.5mm to 25mm
YCS1-Spare
YRT1
Spare Blade for Adjustable Cable Slitter (YCS1)
BNC Removal Tools Allows easy installation and removal of terminated coaxial leads from panels where it can involve working in very tight spaces with large numbers of leads. Part No.
cables
FS
FS cables
Description
YRT1
Removal Tool for BNC connectors 12” long
YRT2
Removal Tool for F-Type connectors 12” long
www.fscables.com
sales@fscables.com
149
TOOLS Kevlar Scissors
YFOS
Designed to cut kevlar, polyaramid or strainer elements in fibre optic cables, these scissors are also ideal to neatly cut copper wire braids on coax or screened data and control cables. Part No.
Description
YFOS
Handle Colour
Scissors for cutting kevlar, polyaramid or braids
Black
Hand Cable Cutters
YCC162
A range of strong yet competitively priced cutters to meet most electricians’ needs. These large heavy duty cable cutters are widely used by wholesalers and cable distributors as well as contractors and installers. Cutting Range
Overall Length mm
YCC162
Part No.
Hand Cable Cutters
Description
Up to 6mm²
160
YCC235
Hand Cable Cutters
Up to 35mm²
235
Cable Cutters - Tubular Steel Handles
YCC350
Compact low cost cutters ideal for site or stockists. Suitable for flexible, data, telecoms and other unarmoured cables. Cutting Range Cu or Al
Overall Length mm
YCC350
Part No.
Hand Cable Cutters
Description
Up to 120mm²
350
YCC540
Hand Cable Cutters
Up to 240mm²
540
YCC700
Hand Cable Cutters
Up to 500mm²
700
Cable Cutters - Cast Aluminium Handles
YCC600
Lightweight yet tough, these cable cutters are ideal where large quantities of cuts are carried out. They are particularly suitable for cable distributors and railway, telecoms and strip-out contractors. Part No.
Overall Length mm
Hand Cable Cutters
Description
Up to 120mm²
320
YCC600
Hand Cable Cutters
Up to 240mm²
600
YCC810
Hand Cable Cutters
Up to 500mm²
810
cables
FS
Cable Cutters - Telescopic Handles
YCCT300
FS
Tough yet compact, these cutters with pull out and twist-to-lock telescopic handles are great for keeping in a tool box. The extending handles also give extra leverage when cutting large cables.
cables
Part No.
Description
FS
cables
Cutting Range Cu or Al
YCC320
Cutting Range Cu or Al
Overall Length mm
Up to 120mm²
300 – 400
Hand Cable Cutters
Up to 240mm²
415 - 565
cables
FS
FS
FS
FS
Cutting Range refers to the total cross-sectional area of the conductors i.e. 1 x 120mm2 or 4 x 25mm2. All dimensions are approximate.
cables
Hand Cable Cutters
YCCT415
cables
YCCT300
FS
Hand cutters should never be forced or have the handles extended to give extra leverage.
Tel: 01727 840 841
Fax : 01727 840 842
cables
cables
150
TOOLS Hydraulic Tools for Cutting Hydraulic cutters are an easy way of cutting large or medium sized copper or aluminium cables. They are particularly useful when working in confined spaces such as panels, transformers or trenches where there may not be sufficient room to use conventional cutters or where the physical force required to cut the cable is too great. Extensively used on site where cutting large armoured cables safely and with minimal effort is required.
YHC600
Hand Operated â&#x20AC;&#x201C; Hydraulic Cutters These hydraulic cutters feature hardened blades to cut most types of telecom, power (including SWA) and large flexible cables. Competitively priced and complete with a steel case these cutters are ideal for use on site. Part No.
Description
Cutting range O/D mm
Cutting Force (Tonnes)
Length mm
YHC600
Hydraulic Cutters
40
12
600
YHC630
Hydraulic Cutters
45
12
630
*YHC600 is also suitable for cutting steel rope up to 28mm in diameter.
YHC560
Hand Operated â&#x20AC;&#x201C; Hydraulic Cutters Features a flip-open cutter head for quick and easy cutting, and a rotatable head for cutting at any angle. The cutter has a two stage hydraulic action for faster cutting and either automatic or manual pressure release at the end or during the cut cycle. Part No.
YHH340
cables
FS
FS
Description
Cutting range O/D mm
Cutting Force
Length mm
YHC560
Hydraulic Cutters
45
60 KN
560
YHC680
Hydraulic Cutters
85
60 KN
680
Hydraulic Cutters Heads Cutting heads are ideal for either working in confined spaces or mounting on equipment or machinery. They can be powered either by hand or foot operated hydraulic pumps or a motorised version linked by a flexible hose. Part No.
Description
Cutting range O/D mm
Cutting Force (Tonnes)
Length mm
YHH340
Hydraulic Cutters
YHH515
Hydraulic Cutters
45
12
340
75
7.5
515
cables
cables
FS
*Please note, all cutters are designed to cut copper and aluminium conductors with most types of insulation or sheath. Some will also cut SWA (armoured cable) and steel tape armour but this will blunt the cutting surface more quickly. Hand cutters should never be forced or have the handles extended to give extra leverage. All dimensions are approximate and colours may vary.
FS cables
www.fscables.com
sales@fscables.com
151
TOOLS Hydraulic Power Pumps
YHP510
Designed to work with hydraulic cutting heads YHH340 & YHH515 the pump will also power crimpers, benders, rebar cutters and hole punches. Part No.
Description
Max. Output Pressure (Low)
Max. Output Pressure (High)
Size mm
YHP510
Hand Hydraulic Power Pumps
20kg/cm²
700kg/cm²
510 x 150 x 200
YHP450
Foot Hydraulic Power Pumps
20kg/cm²
700kg/cm²
450 x 150 x 200
Hand Operated - Hydraulic Tools for Crimping
YHT425
Cost effective crimpers that are easy to operate and ideal for site work. They are packed in a storage box complete with interchangable hexagon crimping dies to cover the crimping range. Fixed crimping head. Part No.
YHT425
Description
Hydraulic Crimp Tool
Crimping Range
Length mm
10 – 120mm²
425
Hand Operated - Hydraulic Tools for Crimping
YHT370
High quality crimpers ideal for rental and hire companies due to their long service life. They are packed in storage cases with a full set of hardened crimping dies to suit. Quick pressure release can be operated at any stage of operation. Rotatable head allows work in confined spaces and both models are suitable for inline crimps. YHT560 has a C shaped crimping head for open access. Part No.
Description
Crimping range
Crimping Force
Length mm
YHT370
Hydraulic Crimp Tool
10 – 150mm²
6
370
YHT560
Hydraulic Crimp Tool
16 – 400mm²
13
560
Compact light weight hole punch for use on panels, trunking and cabinets as well as other mild or stainless steel sheet. Rotatable head allows for comfortable working. Punching Range Part No.
YHP310
Mild Steel ≤ 3mm
Mild Steel ≤ 2mm
16.5 – 60.5
16.5 – 115.5
YHP310
FS
cables
cables
FS
Hand Operated Hydraulic Hole Punch
FS
FS
FS
FS
FS
FS
Stainless Steel ≤ 2mm
16.5 – 60.5 cables
cables
Standard round cutters included, square cutters are also available to order.
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
152
SPECIAL MANUFACTURE N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant Custom-made Cables (IEC 60331) You specify, we supply – with quantities as low as 100 metres in some cases. The options outlined on these pages are the main variations and can be combined in any way to meet your particular specifications. Talk to us about cost-effective solutions for applications that are not mentioned here.
Composite and Special Cables There is an increasing need for cable to be manufactured to customers’ specific requirements. This can be as basic as a special colour code or jacket colour, right through to cables containing mixed core sizes (as well as a coax), with various levels of screening or armouring. At FSC we have considerable experience of ensuring that ‘specials’ meet your design criteria.
Outdoor and Duct Grade Sheaths In situations where the cable runs outside or through ducts polyethylene sheathing is the ideal solution. This material is tough, water-resistant and has natural low friction, making it easy to pull through ducts. It is also ideal for clipping to the outside of buildings offering good resistance to sunlight. cables
FS
FS cables
Two types of polyethylene are used, Low Density (LDPE) and High Density (HDPE). LDPE offers reasonable flexibility and mechanical protection. It is particularly suited to small data cables, while HDPE is much stiffer and is normally used for larger cables where no flexibility is required. Even quantities as low as 100m can be oversheathed, which allows you to use the same basic cable throughout an installation but with the added protection needed.
Special Colours Many cables can be supplied in a range of jacket colours.
cables
FS
FS cables
Existing cables can be coloured either by dyeing if they are PVC, or otherwise oversheathed to match an existing colour scheme or for identifying circuits, for example alarm data wiring. Talk to us about the options available.
www.fscables.com
sales@fscables.com
153
SPECIAL MANUFACTURE Braiding For added protection cables can be braided with a galvanised steel wire braid (GSWB) or heavy tinned copper wire. Braiding maintains a degree of flexibility, which may be important during installation or if the equipment needs to be moved for maintenance or is subject to vibration.
Armouring Armouring is best suited for fixed installations and particularly direct burial. Both types of protection are sheathed with either an exterior grade PVC or polyethylene. Low Smoke Halogen Free sheaths for special installations are also available. Standard cables can be braided or armoured for quantities as low as 100m.
Custom Made Leads & Assemblies For most jobs time is money and you cannot afford to make a mistake. To reduce installation time and cost many system manufactures are now operating a plug and play design allowing the installer to simply plug pre-manufactured leads into modules for right first time termination.
FS
FS
cables
FS
FS
FS
FS
FS
cables
FS
cables
To meet these growing demands we are able to supply many of the coax, data and instrumentation cables listed in the catalogue as pre-terminated leads to save you time and money. All we need to know is the length and the connector type you require - we will do the rest.
Printed Sheaths
cables
Cables can be printed with your company name, telephone number or an identification code such as a batch or location number.
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
154
TECHNICAL Table 4F1A 60oC Thermosetting Insulated Flexible Cables With Sheath, Non-Armoured
Table 4F1A
CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area
1 (mm ) 4 6 10 16 2
25 35 50 70 95
Ambient temperature: 30ยบC Conductor operating temperature: 60ยบC
Single-phase a.c. or d.c.
Three-phase a.c.
Single-phase a.c. or d.c.
1 two-core cable, with or without protective conductor 2
1 three-core, four-core or five-core cable
2 single-core cable
3
4
(A) 30 39 51 73
(A) 26 34 47 63
(A) -
97 -
83 102 124 158 192
140 175 216 258
Refer to Notes 1, 2 & 3 below Notes: 1. The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. If the cable is to be wound on a drum on load the ratings should be reduced in accordance with Note 2 below and for cables which may be covered, Note 3 below. cables
FS
2. Flexible cables wound on reeling drums The current ratings of cables used on reeling drums are to be reduced by the following factors: a) Radial type drum ventilated: unventilated:
FS
b) Ventilated cylindrical type drum 85% 1 layer of cable: 85% 75% 2 layers of cable: 65% 3 layers of cable: 45% 4 layers of cable: 35%
cables A radial type drum is one where spiral layers of cable are accommodated between closely spaced flanges; if fitted with solid flanges the ratings given above should be reduced and the drum is described as non-ventilated. If the flanges have suitable apertures the drum is described as ventilated. A ventilated cylindrical cable drum is one where layers of cable are accommodated between widely spaced flanges and the drum and end flanges have suitable ventilating apertures.
FS
cables
3. Where cable may be covered over or coiled up whilst on load, or the air movement over the cable restricted, the current rating should be reduced. It is not possible to specify the amount of reduction but the table of rating factors for reeling drums can be used as a guide.
FS cables
www.fscables.com
sales@fscables.com
155
Table 4F1B TECHNICAL Table
4F1B
600C Thermosetting Insulated Flexible Cables
VOLTAGE DROP (per ampere per metre): Conductor Two-core crosscable, sectional d.c. area 1
Two-core cable, single-phase a.c.
2
(mm2) (mV/A/m) 4 6 10 16
12 7.8 4.6 2.9
Conductor operating temperature: 60ยบC
d.c.
Single-phase a.c.*
3
4
5
6
(mV/A/m)
(mV/A/m)
(mV/A/m)
(mV/A/m)
12 7.8 4.6 2.9 r
2 single-core cables, touching
1 three-core, four-core or five-core cable, three-phase a.c.
x
10 6.7 4.0 2.5 z
0.175 1.85
r
-
x
-
z
r
x -
z
25
1.80
1.80
1.55
0.150
1.55
-
-
35
-
-
-
-
1.10
0.150
1.15
1.31
1.31
0.21
1.32
-
50
-
-
-
-
0.83
0.145
0.84
0.91
0.91
0.21
0.93
70
-
-
-
-
0.57
0.140
0.58
0.64
0.64
0.20
0.67
95
-
-
-
-
0.42
0.135
0.44
0.49
0.49
0.195
0.53
Notes: * A larger voltage drop will result if the cables are spaced.
These extracts from the 17th Edition Wiring Regulations
FS
FS
FS
cables
FS
FS
FS
FS
FS
cables
Engineering and Technology and British Standards
cables
are reproduced by kind permission of the Institution of Institution. Copyright IET / BSI 2008. The extracts are for guidance only, please refer to
cables
BS 7671: 2008 Requirements for Electrical Installations (IEE Wiring Regulations 17th Edition) for further reference.
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
156
TECHNICAL Table 4D2A & 4D2B Multicore 70oC Thermoplastic Insulated and Thermoplastic Sheathed Cables, Non-Armoured
Table 4D2A
CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area
Reference Method A (enclosed in conduit in thermally insulating wall etc.)
Reference Method B (enclosed in conduit on a wall or in trunking etc.)
1 two1 three1 twocore cable* core cable* core singleor cable* phase 1 four-core singlea.c. or d.c. cable, three- phase phase a.c. a.c. or d.c.
1
Ambient temperature: 30ยบC Conductor operating temperature: 70ยบC Reference Method C (clipped direct)
Reference Method E (free air or on a perforated cable tray etc, horizontal or vertical)
1 three1 two 1 three1 two1 threecore core cable* core cable* core cable* core cable* cable* singleor singleor or phase 1 four-core phase 1 four-core 1 four-core a.c.or d.c. cable, a.c. or d.c. cable, cable, threethreethree phase a.c. phase a.c. phase a.c.
2
3
4
5
6
7
8
9
(mm2)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
1 1.5 2.5 4 6 10 16
11 14 18.5 25 32 43 57
10 13 17.5 23 29 39 52
13 16.5 23 30 38 52 69
11.5 15 20 27 34 46 62
15 19.5 27 36 46 63 85
13.5 17.5 24 32 41 57 76
17 22 30 40 51 70 94
14.5 18.5 25 34 43 60 80
* With or without protective conductor.
Table 4D2B cables
FSConductor cross-
sectional area 1
FS
(mm ) 1 cables 1.5 2.5 4 6 10 16 cables
FS
FS cables
2
VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 70ยบC Two-core cable d.c.
Two-core cable single-phase a.c.
2
3
4
(mV/A/m) 44 29 18 11 7.3 4.4 2.8
(mV/A/m) 44 29 18 11 7.3 4.4 2.8
(mV/A/m) 38 25 15 9.5 6.4 3.8 2.4
www.fscables.com
Three- or four-core cable three-phase a.c.
sales@fscables.com
157
Table 4E2A & 4E2B TECHNICAL
Multicore 90oC Thermosetting Insulated and Thermoplastic Sheathed Cables, Non-Armoured
Table 4E2A
CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area
Reference Method B (enclosed in conduit on a wall or in trunking etc.)
Reference Method A (enclosed in conduit in thermally insulating wall etc.) 1 two1 threecore cable* or four-core singlecable*, phase threea.c. or d.c. phase a.c.
1
2
(mm2) 1 1.5 2.5 4 6 10 16
(A) 14.5 18.5 25 33 42 57 76
Ambient temperature: 30ºC Conductor operating temperature: 90ºC Reference Method E (free air or on a perforated cable tray etc, horizontal or vertical)
Reference Method C (clipped direct)
1 two-core cable*, singlephase a.c. or d.c.
1 threeor four-core cable*, threephase a.c.
1 two-core cable* singlephase a.c.or d.c.
1 threeor four-core cable*, threephase a.c.
1 two-core cable*, singlephase a.c. or d.c.
4
5
6
7
8
9
(A) 15 19.5 26 35 44 60 80
(A) 19 24 33 45 58 80 107
(A) 17 22 30 40 52 71 96
(A) 21 26 36 49 63 86 115
(A) 18 23 32 42 54 75 100
3 (A) 13 16.5 22 30 38 51 68
(A) 17 22 30 40 51 69 91
1 threeor four-core cable*, threephase a.c.
Notes: 1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature (see Regulation 512.1.2) 2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC, the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables (Table 4D2A) must be used (see also Regulation 523.1) * With or without protective conductor.
Table 4E2B VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 90ºC
3
(mV/A/m) 46 31 19 12 7.9 4.7 2.9
(mV/A/m) 46 31 19 12 7.9 4.7 2.9
Tel: 01727 840 841
Fax : 01727 840 842
FS
FS
cables
FS
FS
FS
FS
FS
4
(mV/A/m) 40 27 16 10 6.8 4.0 2.5
cables
cables
cables
2
FS
Three-or four-core cable, three-phase a.c.
cables
Two-core cable single-phase, a.c.
cables
(mm2) 1 1.5 2.5 4 6 10 16
Two-core cable, d.c.
cables
Conductor crosssectional area 1
cables
cables
FS
FS
cables
cables
FS
FS
cables
www.fscables.com
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ยบC, the current ratings given in the equivalent table for 70ยบC thermoplastic insulated cables (Table 4D1A) must be used (see also Regulation 523.1)
1. Where a conductor operates at a temperature exceeding 70ยบC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature (see Regulation 512.1.2)
Notes:
26
35
45
61
81
106
131
158
200
241
6
10
16
25
35
50
70
95
1.5
4
14
19
1
2.5
2
(A)
1
2 cables, singlephase a.c. or d.c.
sales@fscables.com 216
179
141
117
95
73
54
40
31
23
17
13
(A)
3
3 or 4 cables, threephase a.c.
Reference Method A (enclosed in conduit in thermally insulating wall etc.)
(mm2)
Conductor crosssectional area
306
253
198
164
133
100
75
54
42
31
23
17
(A)
4
2 cables, singlephase a.c. or d.c.
269
222
175
144
117
88
66
48
37
28
20
15
(A)
5
3 or 4 cables, threephase a.c.
Reference Method B (enclosed in conduit on a wall or in trunking etc.)
355
293
228
176
143
109
81
59
46
34
25
19
(A)
6
2 cables, singlephase a.c. or d.c. flat and touching
326
268
209
161
130
99
74
54
41
31
23
17.5
(A)
7
3 or 4 cables threephase a. c. flat and touching or trefoil
Reference Method C (clipped direct)
CURRENT-CARRYING CAPACITY (amperes):
377
310
242
200
161
-
-
-
-
-
-
-
(A)
8
342
279
216
176
141
-
-
-
-
-
-
-
(A)
9
2 cables, 3 singlecables, phase a.c. three-phase or d.c. flat a.c.flat
328
268
207
169
135
-
-
-
-
-
-
-
(A)
10
3 cables, threephase a.c. trefoil
Reference Method F (in free air on a perforated cable tray horizontal or vertical etc.) Touching
430
353
275
226
182
-
-
-
-
-
-
-
(A)
11
Horizontal
389
318
246
201
161
-
-
-
-
-
-
-
(A)
12
Vertical
2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat
Spaced by one cable diameter
Reference Method G (in free air)
Ambient temperature: 30ยบC Conductor operating temparature:90ยบC
Table
Single Core 90oC Thermosetting Insulated Cables, Unarmoured, With or Without Sheath
158 TECHNICAL Table 4E1A
4E1A
0.68 0.26 0.73
0.68 0.175 0.71
0.70 0.28 0.75
0.68
70
0.51 0.27 0.58
cables
FS
cables
FS
cables
FS 0.49 0.170 0.52
0.49 0.26 0.56
Notes: *Spacings larger than one cable diameter will result in a larger voltage drop.
0.49
0.99 0.27 1.00
0.99 0.180 1.00
1.00 0.29 1.05
0.99
50
FS cables
Fax : 01727 840 842
95
1.35 0.27 1.35
1.35 0.180 1.35
1.35 0.29 1.35
1.35
x
z
35
r 1.85 0.28 1.85
x
z
1.85 0.190 1.85
r
1.85 0.31 1.90
z
1.85
x
(mV/A/m) 46 31 19 12 7.9 4.7 2.9
25
r
(mV/A/m) 46 31 19 12 7.9 4.7 2.9
(mV/A/m) 46 31 19 12 7.9 4.7 2.9
(mV) 46 31 19 12 7.9 4.7 2.9
5
Cables spaced*
(mm2) 1 1.5 2.5 4 6 10 16
4
3
Cables touching
Reference Methods C, F & G (clipped direct, on tray or in free air)
2
cables
Tel: 01727 840 841
FS
cables
1
Reference Methods A & B (enclosed in conduit or trunking)
2 cables, single-phase a.c.
VOLTAGE DROP (per ampere per metre):
2 cables d.c.
x
z
0.44 0.23 0.50
0.60 0.24 0.65
0.87 0.25 0.90
1.15 0.25 1.15
1.60 0.27 1.65
r
(mV/A/m) 40 27 16 10 6.8 4.0 2.5
Reference Methods A & B Reference (enclosed in conduit or trunking) 6
Conductor operating temperature: 90ยบC
x
z
0.43 0.145 0.45
0.59 0.150 0.61
0.86 0.155 0.87
1.15 0.155 1.15
1.60 0.165 1.60
r
(mV/A/m) 40 27 16 10 6.8 4.0 2.5
Cables touching, Trefoil 7
x
z
0.43 0.170 0.46
0.59 0.175 0.62
0.86 0.180 0.87
1.15 0.180 1.15
1.60 0.190 1.60
r
(mV/A/m) 40 27 16 10 6.8 4.0 2.5
Cables touching, Flat 8
x
z
0.43 0.25 0.49
0.59 0.25 0.65
0.86 0.26 0.89
1.15 0.26 1.20
1.60 0.27 1.65
r
(mV/A/m) 40 27 16 10 6.8 4.0 2.5
Cables spaced*, Flat 9
Reference Methods C, F & G (clipped direct, on tray or in free air)
3 or 4 cables, three-phase a.c.
Table
Conductor crosssectional area
Single Core 90oC PVC Thermosetting Insulated Cables
Table 4E1B TECHNICAL
159
4E1B
FS
FS
cables
FS
cables
160
TECHNICAL Table 4F2A
4F2A
Table
90oC and 180oC Thermosetting Insulated Flexible Cables With Sheath, Non-Armoured Ambient temperature: 30ºC Conductor operating temperature: 90ºC
CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area
d.c. or single-phase a.c. (1 two-core cable, with or without protective conductor)
Three-phase a.c. (1 three-core, four-core or five-core cable)
Single-phase a.c. or d.c., 2 single-core cables, touching
1
2
3
4
(A) 42 55 76 103 136 -
(A) 37 49 66 89 119 146 177 225 273
(A) 200 250 310 369
(mm ) 4 6 10 16 25 35 50 70 95 2
Refer to Notes 1 to 3 on page 154 and Notes 4 to 6 below
RATING FACTOR FOR AMBIENT TEMPERATURE: 90ºC thermosetting insulated cables: cables
FS
Ambient temperature
35ºC 40ºC
45ºC
50ºC
55ºC
60ºC
65ºC
70ºC
75ºC
80ºC
85ºC
Rating factor
0.95 0.91
0.86
0.82
0.76
0.70
0.64
0.57
0.50
0.40
0.28
180ºC thermosetting insulated cables:
FS
Ambient temperature 35ºC to 90ºC cables Rating factor 1.0
95ºC 100ºC 105ºC 110ºC 0.96
0.91
0.86
0.81
115ºC 120ºC 125ºC 130ºC 135ºC 140ºC 145ºC 0.76
0.70
0.64
0.57
0.50
0.40
0.28
Notes: 4. For 180ºC cables the rating factors for ambient temperature allow a conductor operating temperature up to 150ºC. Consult the cable manufacturer for further information. cables
FS
5. The temperature limits given in the 17th Edition Wiring Regulations hould be taken into account when it is intended to operate these cables at maximium permissible temperature.
6. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temeperature (see Regulation 512.1.2)
FS cables
www.fscables.com
sales@fscables.com
161
Table 4F2B TECHNICAL Table
4F2B
90oC and 180oC Thermosetting Insulated Flexible Cables
VOLTAGE DROP (per ampere per metre): Conductor crosssectional area
1 two-core or 2 singlecore cables d.c.
1 (mm2) 4 6 10 16 25 35
2.03 1.42
50 70 95
1.00 0.71 0.54
1 three-core, four-core or five-core cable, three-phase a.c.
Two-core cable, single-phase a.c.
2 single-core cables, touching Single-phase a.c.*
2 (mV/A/m) 13.2 8.5 5.1 3.2
Conductor operating temperature: 90ยบC
3 (mV/A/m) 13.2 8.5 5.1 3.2 r x 2.03 0.175 -
-
4
z 2.04 -
5
(mV/A/m) 11.1 7.4 4.4 2.7 r x 1.73 0.15 1.22 0.15
z 1.73 1.23
0.91 0.62 0.47
0.93 0.64 0.49
0.145 0.14 0.135
r 1.44
(mV/A/m) x 0.21
z 1.46
1.00 0.71 0.54
0.21 0.20 0.195
1.02 0.73 0.57
Notes: 1. The voltage drop figures given above are based on a conductor operating temperature of 90ยบC and are therefore not accurate when the operating temperature is in excess of 90ยบC. In the case of the 180ยบC cables with a conductor temperature of 150ยบC the above resistive values should be increased by a factor of 1.2. 2 * A larger voltage drop will result if the cables are spaced.
FS
cables
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
FS
cables
FS
cables
162
TECHNICAL Table 4F3A
4F3A
Table
Flexible Cords, Non-Armoured
CURRENT-CARRYING CAPACITY (amperes): and MASS SUPPORTABLE (kg): Current-carrying capacity
Conductor cross-sectional area
Single-phase a.c.
Three-phase a.c.
1
Maximum mass supportable by twin flexible cord (see Regulations 522.7.2 and 559.6.1.5)
2
3
4
2
(mm )
(A)
(A)
(kg)
0.5 0.75 1 1.25 1.5 2.5 4
3 6 10 13 16 25 32
3 6 10 16 20 25
2 3 5 5 5 5 5
Where cable is on a reel see the notes to the Table in 4F1A RATING FACTOR FOR AMBIENT TEMPERATURE 60ºC Thermoplastic or Thermosetting Insulated Cords: 35ºC 40ºC 45ºC 50ºC Ambient temperature Correction factor 0.91 0.82 0.71 0.58
55ºC 0.41
90ºC Thermoplastic or Thermosetting Insulated Cords: Ambient temperature 35ºC to 50ºC 55ºC 60ºC 65ºC Correction factor 1.0 0.96 0.83 0.67
70ºC 0.47
Ambient temperature Correction factor
cables
FS180ºC Thermosetting Insulated Cords:
FS
Glass Fibre Cords: Ambient temperature cables Correction factor
35ºC to 120ºC 1.0
125ºC 0.96
130ºC 0.85
135ºC 0.74
140ºC 0.60
145ºC 0.42
35ºC to 150ºC 1.0
155ºC 0.92
160ºC 0.82
165ºC 0.71
170ºC 0.57
175ºC 0.40
cables
FS
FS cables
www.fscables.com
sales@fscables.com
163
Table 4F3B TECHNICAL Table
4F3B
Flexible Cords Current Carrying Capacity / Voltage Drop
VOLTAGE DROP (per ampere per metre):
Conductor operating temperature: 60ยบC*
Conductor cross-sectional area
d.c. or single-phase a.c.
1
2
Three-phase a.c. 3
(mm2) 0.5 0.75 1 1.25 1.5 2.5 4
(mV/A/m) 93 62 46 37 32 19 12
(mV/A/m) 80 54 40 27 16 10
Notes: *The tabulated values above are for 60ยบC thermoplastic or thermosetting insulated flexible cords and for other types of flexible cords they are to be multiplied by the following factors: For 90ยบC Thermoplastic or Thermosetting Insulated
1.09
180ยบC Thermosetting Insulated
1.31
185ยบC Glass Fibre
1.43
FS
cables
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
FS
cables
FS
cables
164
TECHNICAL AWG/Metric Conversion
American Wire Gauge to Metric Conversion - Listed below are some of the most popular strandings, however, many other combinations exist. Resistance figures are approximate and are given for guidance only.
cables
FS
FS cables
cables
FS
FS cables
AWG
Cross Section mm2
Stranding
Resistance Ohm/km
AWG Cross Section Stranding mm2
38
0.008
1 x 0.10
2125
18
0.90
7 x 0.40
38
0.009
7 x 0.04
1930
18
0.96
19 x 0.25
17.9
36
0.013
1 x 0.12
1360
16
1.30
1 x 1.29
13.2
36
0.014
7 x 0.05
1217
16
1.23
19 x 0.28
14.0
34
0.020
1 x 0.16
856
14
2.08
1 x 1.62
8.28
34
0.022
7 x 0.06
777
14
1.94
19 x 0.36
8.86
32
0.032
1 x 0.20
538
12
3.31
1 x 2.05
5.20
32
0.034
7 x 0.08
538
12
3.08
19 x 0.45
5.58
32
0.035
19 x 0.05
446
10
5.26
1 x 2.58
3.28
30
0.051
1 x 0.25
338
10
5.26
19 x 0.6
3.28
30
0.057
7 x 0.10
338
8
8.38
1 x 3.26
2.06
30
0.059
19 x 0.06
286
8
8.35
19 x 0.75
2.06
28
0.080
1 x 0.32
213
6
13.29
1 x 4.11
1.59
28
0.089
7 x 0.12
213
6
13.29
19 x 0.96
1.59
28
0.090
19 x 0.08
186
4
21.15
1 x 5.18
0.815
26
0.128
1 x 0.40
134
4
21.14
19 x 1.19
0.815
26
0.141
7 x 0.16
122
2
33.63
1 x 6.54
0.513
26
0.155
19 x 0.10
113
2
33.61
19 x 1.50
0.513
24
0.205
1 x 0.51
84
1
42.41
1 x 7.34
0.424
24
0.227
7 x 0.20
76
1
42.38
19 x 1.68
0.424
24
0.241
19 x 0.12
69
1/0
53.4
19 x 1.89
0.253
22
0.324
1 x 0.64
53
2/0
67.4
19 x 2.17
0.291
22
0.355
7 x 0.25
48
4/0
107
19 x 2.68
0.182
22
0.382
19 x 0.16
45
250 MCM
127
37 x 2.09
0.139
20
0.519
1 x 0.81
33
300 MCM
152
37 x 2.29
0.119
20
0.563
7 x 0.32
30.4
350 MCM
177
37 x 2.47
0.102
20
0.616
19 x 0.20
28.3
400 MCM
202
37 x 2.64
0.091
18
0.785
16 x 0.25
21.2
500 MCM
253
37 x 2.95
0.072
18
0.823
1 x 1.02
20.9
www.fscables.com
Resistance Ohm/km 19.2
sales@fscables.com
165
Stranding Chart TECHNICAL Cross Section mm2
Nearest AWG Size*
Stranding Class 1
Stranding Class 2
Resistance Ohm/km Classes 1 & 2
Stranding Class 5
Stranding Class 6
Resistance Ohm/km Classes 5 & 6
Approx Weight kg/km
IEC 60228/BS 6360 Conductors for insulated cables 0.14
26
-
-
-
-
18 x 0.10
138
1.35
0.25
24
-
-
-
14 x 0.16
32 x 0.10
79
2.4
0.34
22
-
-
-
19 x 0.16
42 x 0.10
57
3.3
0.50
20
1 x 0.80
7 x 0.30
36.0
16 x 0.21
28 x 0.16
38
4.8
0.75
18
1 x 0.97
7 x 0.37
24.5
24 x 0.21
42 x 0.16
26
7.2
1.0
18
1 x 1.13
7 x 0.43
18.1
32 x 0.21
56 x 0.16
19.5
9.6
1.5
16
1 x 1.38
7 x 0.53
12.1
30 x 0.26
84 x 0.16
13.3
14.4
2.5
14
1 x 1.78
7 x 0.67
7.41
50 x 0.26
140 x 0.16
7.98
24
4.0
12
1 x 2.26
7 x 0.85
4.61
56 x 0.31
224 x 0.16
4.95
38
6.0
10
1 x 2.76
7 x 1.04
3.08
84 x 0.31
192 x 0.21
3.3
58
10
8
1 x 3.57
7 x 1.35
1.83
80 x 0.41
320 x 0.21
1.91
96
16
6
1 x 4.5
17 x 1.70
1.15
128 x 0.41
512 x 0.21
1.21
154
25
4
–
7 x 2.14
0.72
200 x 0.41
800 x 0.21
0.78
240
35
2
–
7 x 2.52
0.52
280 x 0.41
1120 x 0.21
0.55
336
50
1/0
–
19 x 1.78
0.39
400 x 0.41
705 x 0.31
0.39
480
70
2/0
–
19 x 2.14
0.27
356 x 0.51
990 x 0.31
0.27
672
95
3/0
–
19 x 2.52
0.19
485 x 0.51
1340 x 0.31
0.21
912
120
250MCM
–
37 x 2.03
0.15
614 x 0.51
1690 x 0.31
0.16
1152
150
300MCM
–
37 x 2.25
0.12
765 x 0.51
2123 x 0.31
0.13
1440
185
400MCM
–
37 x 2.52
0.1
944 x 0.51
1470 x 0.41
0.11
1776
240
500MCM
–
61 x 2.25
0.07
1225 x 0.51
1905 x 0.41
0.08
2304
300
600MCM
–
61 x 2.52
0.06
1530 x 0.51
2385 x 0.41
0.064
2880
400
750MCM
–
61 x 2.85
0.05
2035 x 0.51
–
0.068
3840
500
1000MCM
–
61 x 3.20
0.04
1768 x 0.60
–
0.0384
4800
FS
FS
cables
FS
FS
FS
FS
FS
cables
cables
FS
The number of strands according to IEC 60228/BS 6360 shown in classes 1 & 2 is obligatory. Stranding shown in classes 5 & 6 gives the maximum strand diameters and may have less strands provided the conductor does not exceed the resistance figures shown. In either case the standard gives the maximum resistance in ohms/km that is permissable for non-tinned conductors. * AWG sizes are approximate and for information only. Please contact us for exact sizing.
Fax : 01727 840 842
cables
cables
cables
Tel: 01727 840 841
cables
cables
166
TECHNICAL Colour Codes - American Style Colour Chart 1: Conductor/Colour
1 2 3 4
Black White Red Green
5 6 7 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red
1 2 3 4 5 6 7 8 9 10 11 12 13
Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White Red/Green Red/Blue Red/Yellow Red/Brown Red/Orange
Brown Blue Orange Yellow
9 10 11
Purple Grey Pink
35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
White/Red/Orange Orange/White/Blue White/Red/Blue Black/White/Green White/Black/Green Red/White/Green Green/White/Blue Orange/Red/Green Blue/Red/Green Black/White/Blue White/Black/Blue Red/White/Blue Green/Orange/Red Orange/Red/Blue Blue/Orange/Red Black/Orange/Red
27 28 29 30 31 32 33 34 35 36 37
Brown/Orange Orange/Yellow Purple/Orange Purple/Red Purple/White Purple/Dark Green Purple/Light Blue Purple/Yellow Purple/Brown Purple/Black Grey/White
Colour Chart 2: Conductor/Colour 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White Orange Black/White/Orange
Colour Chart 3: Pair/Number Colour Combination
cables
FS
1 2 3 4 5 cables 6 7 8 9 10 11 12 13 14 15
FS cables
FS
FS cables
14 15 16 17 18 19 20 21 22 23 24 25 26
Green/White Green/Blue Green/Yellow Green/Brown Green/Orange White/Blue White/Yellow White/Brown White/Orange Blue/Yellow Blue/Brown Blue/Orange Brown/Yellow
Colour Chart 5: Western Electric Standard & CW1308 Telephone Cable Colour Chart
White/Blue White/Orange White/Green White/Brown White/Grey Red/Blue Red/Orange Red/Green Red/Brown Red/Grey Black/Blue Black/Orange Black/Green Black/Brown Black/Grey
Pair number/colour combination. The second colour denotes the band or stripe, however due to environmental issues the cores may be solid colours instead of bi-colours. Blue/White 16 Yellow/Blue Blue/Yellow Orange/White 17 Yellow/Orange Orange/Yellow Green/White 18 Yellow/Green Green/Yellow Brown/White 19 Yellow/Brown Brown/Yellow Grey/White 20 Yellow/Grey Grey/Yellow Blue/Red 21 Purple/Blue Blue/Purple Orange/Red 22 Purple/Orange Orange/Purple Green/Red 23 Purple/Green Green/Purple Brown/Red 24 Purple/Brown Brown/Purple Grey/Red 25 Purple/Grey Grey/Purple Blue/Black 26 Pink/Blue Blue/Pink Orange/Black 27 Pink/Orange Orange/Pink Green/Black 28 Pink/Green Green/Pink Brown/Black 29 Pink/Brown Brown/Pink Grey/Black 30 Pink/Grey Grey/Pink
www.fscables.com
sales@fscables.com
167
Colour Codes - European / UK TECHNICAL CW1600 Colour Codes Pairs
Colour of Insulation A-Wire B-Wire
1 2 3 4 5 6 7 8 9
White/Blue White/Orange White/Green White/Brown White/Grey Red/Blue Red/Orange Red/Green Red/Brown
Pairs
Blue Orange Green Brown Grey Blue Orange Green Brown
Colour of Insulation A-Wire B-Wire
9 10 11 12 13 14 15 16 17
Red/Brown Red/Grey Black/Blue Black/ Orange Black/Green Black/Brown Black/Grey Yellow/Blue Yellow/Orange
Pairs
Brown Grey Blue Orange Green Brown Grey Blue Orange
17 18 19 20 21 22 23 24 25
Colour of Insulation A-Wire B-Wire
Yellow/Orange Yellow/Green Yellow/Brown Yellow/Grey Violet/Blue Violet/Orange Violet/Green Violet/Brown Violet/Grey
Orange Green Brown Grey Blue Orange Green Brown Grey
On cables with over 25 pairs the first 20 pairs will be repeated with coloured separators or binder tapes to indicate each bundle.
Def Style Miniature Cables
CW1128 & CW1128/1198 Colour Coding Pair
A-Wire
B-Wire
1 2 3 4 5 6 7 8 9
White White White White White Red Red Red Red
Blue Orange Green Brown Grey Blue Orange Green Brown
10
Red
Grey
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Colours of tape lappings
1 2 3 4 5
Blue Orange Green Brown Grey
6 7 8 9 10
White Red Black Yellow Violet
Red Blue Green Yellow White Black Brown Violet Orange Pink Turquoise Grey Red/Blue Green/Red Yellow/Red White/Red Red/Black Red/Brown
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
Yellow/Blue White/Blue Blue/Black Orange/Blue Green/Blue* Grey/Blue* Yellow/Green White/Green* Green/Black Orange/Green* Grey/Green Yellow/Brown White/Brown Brown/Black Grey/Brown Yellow/Violet Violet/Black White/Violet
* Note: The colour code of 25 core cables has core colours 23 & 24 replaced with colours 26 & 28. For colour codes above 36 cores please ask for details.
HD 308 S2 BS 7671 Amendment 2: 2004 Colour Code New European Harmonised Standard For Mains Cables
FS
cables
FS
cables
Other colour codes for external telephone cables also exist.
The new colour code for mains cables is obligatory from April 2006 and applies to flexible and fixed cables connected to the mains. It does not apply to control or signal. Two Core Three Core Four Core Five Core Blue Green/Yellow Green/Yellow Green/Yellow Brown Brown Blue cables cables Blue Black Brown Brown Grey Black Cables without earth core: Grey or Green /Yellow Brown Blue Cables without earth core: Black Brown Blue Grey Black Brown Black Cables without earth core: Grey Blue Black DIN 47100 European Colour Codes Brown
FS
FS
Black Grey
See page 80
Tel: 01727 840 841
Fax : 01727 840 842
FS
FS
cables
cables
FS
cables
FS
cables
168
TECHNICAL Colour Codes - BS 5308
BS 5308 Part 1 Colour Code
BS 5308 Part 2 Colour Code
Unscreened & Collective Screened
Unscreened & Collective Screened
Pair No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 cables 46 47 48 49 50 cables
FS
FS FS
A - Wire
B - Wire
Black Black Blue Black Blue Green Black Blue Green Brown Black Blue Green Brown White Black Blue Green Brown White Red Black Blue Green Brown White Red Orange Black Blue Green Brown White Red Orange Yellow Black Blue Green Brown White Red Orange Yellow Grey Black Blue Green Brown White
Blue Green Green Brown Brown Brown White White White White Red Red Red Red Red Orange Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Yellow Yellow Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Violet Violet Violet Violet Violet Violet Violet Turquoise Turquoise Turquoise Turquoise Turquoise
cables
Single Quad (2 pair): Black, Blue, Green, Brown Single Triple: Blue, Black, Green Individually screened pairs can also be identified by a polyester tape over black and blue pairs
FS cables
Pair No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
A - Wire
B - Wire
White White White White White Red Red Red Red Red Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow White-Blue White-Blue White-Blue White-Blue White-Blue Red-Blue Red-Blue Red-Blue Red-Blue Red-Blue Blue-Black Blue-Black Blue-Black Blue-Black Blue-Black Yellow-Blue Yellow-Blue Yellow-Blue Yellow-Blue Yellow-Blue White Orange White Orange White Orange White Orange White Orange Orange-Red Orange-Red Orange-Red Orange-Red Orange-Red
Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey
Single Quad (2 pair): Blue, Green, Orange, Brown Single Triple: Blue, White, Orange Individually screened pairs can also be identified by a polyester tape over white and blue pairs
www.fscables.com
sales@fscables.com
169
LSHF Buyers Guide TECHNICAL Low Smoke Halogen Free Cabling When specifying cable for installations in confined areas, computer rooms and other sensitive environments, Low Smoke Halogen Free cables offer significant advantages over traditional PVC. Hospitals, airports and train stations are just some examples of areas that can be difficult to evacuate in the event of fire. It is now recognised that smoke and poisonous fumes can pose a far greater threat to life and property than the fire itself. Standard PVC cables are made up of halogens which, when burnt, give off toxic gases such as Hydrogen Chloride. When exposed to water – moisture in the air or fire sprinkler systems for example, hydrogen chloride forms highly noxious and corrosive hydrochloric acid.
3m³ smoke test to IEC 61034
The effects of burning PVC are two-fold. Firstly, the dense smoke produced can reduce visibility and obscure exit routes. Secondly the harmful hydrogen chloride gas given off is dangerous to people and also has a corrosive effect on electronic equipment potentially causing random, unpredictable failure over a period of time. Specifying Low Smoke Halogen Free (LSHF) cable goes a long way to reducing this risk. LSHF cables are those which emit negligible amounts of halogens when burnt and have reduced smoke emission properties. Compared with around 28% acid gas emissions of standard PVC, LSHF cables give off less than 0.5% HCl (Gases Evolved During Combustion BS EN 50267, IEC 60754-2). Visibility through smoke emission is measured through a 3m³ smoke test (pictured) to IEC 61034. Confusion still surrounds the terminology used to describe LSHF cables and caution should be exercised when specifying. While LSHF, LS0H, LSZH and 0HLS are the same, it is important to note that LSF is not. LSF (Low Smoke and Fume) often refers to modified PVC compound which can still emit up to 22% HCl and should be regarded as only slightly better than PVC in the event of fire. Also beware standard PVC cables which are over-sheathed with a LSHF compound. When the jacket burns through the PVC inner sheath or insulation will give off poisonous fumes in just the same way. The FSC range of LSHF cables are LSHF throughout – insulation and sheath.
FS
cables
FS
FS
FS
FS
FS
Fax : 01727 840 842
cables
cables
cables
cables
Tel: 01727 840 841
cables
FS
cables
FS
If you are unsure of what you are buying, ask for written confirmation that the cable is LSHF throughout.
cables
170
TECHNICAL Certificates & Trade Associations
ISO 9001 Accredited ISO 9001 is the internationally recognised standard for the quality management of businesses. Quality of service and products has been critical to our operation ever since we began. FS Cables has been a registered company with Quality Certification since 1996.
ISO 14001 Accredited ISO 14001 provides a framework for reducing our environmental footprint through a range of measurable improvement actions. At FS Cables we believe this accreditation demonstrates our commitment to environmental responsibility and sustainability. We have introduced a number of measures ranging from setting up a recycling up a recycling programme programme for for all office all office andand commercial commercial waste waste to car to sharing car sharing andand staffstaff cycling cycling or walking or walking to work. to work.
cables
FS
FS cables
ISO 14001inAccredited Investors People The 14001 ISO Investors provides in People a framework (IIP) Standard for reducing is a business our improvement environmentaltool footprint through designed to advance a range an organisationâ&#x20AC;&#x2122;s of measurable performance improvement through actions. its employees. At FS Cables we believe this accreditation demonstrates our commitment Awarded in 2005, to environmental the IIP Standard responsibility places strong and emphasis sustainability. on the personal development of our staff through regular review, evaluation We have introduced a number of measures ranging from setting up and assessment. a recycling programme for all office and commercial waste to car sharing By establishing and staff a culture cycling of or continuous walking to work. improvement through training we can ensure that you receive the best possible service.
cables
FS
FS cables
www.fscables.com
sales@fscables.com
171
Certificates & Trade Associations TECHNICAL
Link-up Registered
Caplink Ltd T/A Flexible & Specialist Cables Supplier Number: 22288
Date Printed: Expiry Date: Certificate Number:
31 March 2010 28 March 2011 4282-22288/70006
Peter Brookes Rail Sector Manager Achilles Information Limited
Link-up is the UK Rail industry supplier qualification and verification scheme, designed to assure the quality of products and services bought by the rail industry. It is administered on behalf of the rail industry by the Achilles Link-up Team and is supported and used by most of the major rail companies throughout the UK.
BSI Subscribing Member Subscribing membership to the BSI (British Standards Institute) ensures FS Cables can stay up to date with the latest standards and certification programmes. This enables us to adopt best practices in terms of our operations ensuring the products and services we offer our customers are to the highest standards.
KNX Manufacturer Member The KNX standard is an internationally recognised system for home automation and building control.
FS
FS
cables
FS
cables
FS
FS Cables is a manufacturer member of both the KNX worldwide and KNX UK Associations.
CEDIA Trade Supplier The Custom Electronic Design & Installation Association (CEDIA) is an organisation of experienced companies involved in the design andcables cables installation of electronic systems for the home. A number of products for home automation and building control are offered from stock. Please see page 40-41.
Tel: 01727 840 841
Fax : 01727 840 842
FS
FS
cables
cables
FS
cables
FS
cables
172
TECHNICAL Index
318-TQ
137
A Access Control Alarm Cables Antennax™ Feeder Coaxial Armoured Data & Coaxial Cables AUDIO CABLES AWG / Metric Conversion Chart
56 58 38-39 61 49-53 164
B BFOU Instrumentation to IEC 60092-376 BFOU Power to IEC 60092-353 Broadcast & Camera Coaxial BS 5467 Armoured PVC Power 0.6/1kV BS 6724 Armoured LSHF Power 0.6/1kV BS 6883 0.6/1kV Shipwiring Power BS 6883 657-SW4 Unarmoured Shipwiring Instrumentation BS 6883 658-SW4 Armoured Shipwiring Instrumentation BS 7917 0.6/1kV Shipwiring Power Fire Resistant BS 7917 657M-SW4 Unarmoured Shipwiring Instrumentation - Fire Resistant BS 7917 658M-SW4 Armoured Shipwiring Instrumentation - Fire Resistant BUS CABLES
116-117 114-115 32 97 98 102-103
cables cables
FS
FS cables
6-27 42 90 88-89 43 36, 60 52
E Echelon LonWork System Cabling Equipment Wire LSHF
44 95
F FIRE & SECURITY CABLES Fire Alarm Cable Standard & Enhanced Flat PVC Cables 122 Flat Speaker Cables FT Data & Coaxial
54-61 54, 63 50 55, 63
G 106-107
GLANDS G-Temp 600
144-146 136
108-109
H 110-111 112-113 42-48
Cable Standards Cross Reference Chart 172 CAN Bus Cables 42 Cat-3 Multipair 27 Cat-5 Multipair 27 Cat-5E UTP & FTP 24-25, 26, 60-61, 62 Cat-6A UTP & FTP 25, 26, 60-61 Cat-7 25 CC-Link 1.10 FieldLink® Cables 43 COAXIAL CABLES 28-39 COLOUR CODE CHARTS 166-168 Composite Coaxial Cables 37, 57 CUSTOM MANUFACTURED CABLES 152-153 cables CW1044 Functional Earth 67 CW1128 External 68 CW1128/1198 Armoured 69 CW1308 LSHF Internal 65 CW1308 PVC Internal 64 CW1411 & CW1417 BT Drop Wire 67 CW1600 LSHF Limited Fire Hazard 66 CY PVC Bedded Screened Multicore 94
FS
DATA CABLES Databus® Foundation Fieldbus Cables Def-Standard LSHF Multicore Def-Standard PVC Multicore DeviceNet™ Cables Digital Satellite & Cable TV Coaxial DMX Cables
104-105
C
FS
D
H05RR-F H07RN-F HD Media Composite Cables HDMI Cables HF-120 Unscreened & HF-120-C Screened HF-120-C-TP Paired Screened HF-265 PUR Encoder HF-275 PUR Servo & Feedback Cables Hi-Flex HF-100 & HF-100-C PUR HIGH TEMPERATURE CABLES HOME AUTOMATION CABLES
118 119 40-41 53 126 127 128 129 124-125 130-137 40-41
I IBM Cables, Ethernet Cables & Twin-Ax Cables 22 Individual & Overall Screened Multipair Data Cable 24AWG RS422 Low Capacitance 18 Individually Screened Multipair Data Cable 20AWG & 18AWG 19 Individually Screened Multipair Data Cable 22AWG Low Capacitance RS422 13, 56, 60-61 Individually Screened Multipair Data Cable 24AWG Low Capacitance RS422 14, 60-61 Individually Screened Two Pair Data Cable 22AWG 12, 56, 60-61 Industrial Ethernet Cables 44 Instrumentation, Process Control & PLTC 21 Interbus Cables 44
www.fscables.com
sales@fscables.com
173
Index TECHNICAL J
P
J-H(St)H LSHF
71
Jointing Kits
147
J-Y(St)Y PVC
70
Parallel Speaker Cables
50
Photovoltaic cables
123
Pilz Safety Bus®
45
POWER CABLES
K
96-101
Profibus
KNX Cables
47
L LF-249
91
45
P-Temp 260
135
PTFE Single Cores
134
R
LiYCY PVC Screened Multicores
78-79
Reelflex PUR-H Drum Reeling
LiYCY-TP PVC Screened Pairs
80-81
RG Coaxial
LiYY Miniature Signal Cable LONDON UNDERGROUND APPROVED CABLES Lutron Grafik Eye Cables
74
RiserFlex 0.6/1kV86
62-63
RiserShield 0.6/1kV
46
M MARINE, OIL & GAS CABLES
102-117
Microphone Cables
49
Modbus
45
Mode Lighting Cables
46
Multicore Speaker Cables
51
Multiple Star Quad Cables
49
121
28-31, 60-61 87
ROBOTICS CABLES
124-129
RUBBER & CRANE CABLES
118-123
S Safe-T-Shield
99
SIGNAL & CONTROL CABLES
72-95
Silicone Multicores
132-133
Silicone Single Cores
130-131
Simmtronic Specs 3 & Lighting Multicores Single Core Enhanced Circuit Integrity
96
Single Pair Screened Data Cable
N Niltox™ LF-315 LSHF
84
Niltox™ LF-316 LSHF
85
Niltox™ LF-329 LSHF
82-83
Niltox™ LF-318 LSHF
75
Niltox™ LF-319 LSHF
76-77
NSHTöu Drum Reeling
142-143
Stranding Chart
165
Structured Wiring External Grade
26
S-Video Cables
53
SY PVC Steel Braided Multicore
92-93
FS
Telecom BT, TZC & RA Coaxial
Outdoor Control Cables
59
TELEPHONE CABLES
Outdoor Data & Coaxial Cables
60
THERMOCOUPLE CABLES
Overall Foil & Braid Screened Cored Data Cable RS232 & RS423
33 64-71
FS
Three Core Overall Screened Data Cable 16
TOOLS
Transducer & Load Cell Cablescables
Overall Foil & Braid Screened Data Cables RS232 & RS422
FS
154-174
cables
T TECHNICAL TABLES
O
52
SPIRAL CABLES
cables
100-101
8, 60
Snake Cables
120
NYY Unarmoured Power
48
138-141
FS 9
148-151
cables 23
20
Overall Foil & Braid Screened Paired Data Cable
U
24AWG RS485 Low Capacitance
Unscreened Paired Data Cable
15, 56, 60-61
Overall Foil & Braid Screened Paired Data Cable 17
Overall Screened Multicore Data Cable RS232
10
Overall Screened Multipair Data Cable RS232
11, 60
Tel: 01727 840 841
Y
FS
YY PVC
Fax : 01727 840 842
34-35
FS
cables
RS232 & RS422
7, 57 cables
URM Coaxial
59, 72-73
FS
cables
FS cables
174
TECHNICAL Cable Standards Cross Reference Chart Alternative Standard References
Conductor Stranding Standard IEC 60228
Description Conductor class, stranding and resistance for electric cables.
BS 6360
VDE 0295
Alternative Standard References
Flame Retardant Tests Standard
EN 60228
Requirements
IEC 60332-1-2
Vertical flame test on a single wire or cable.
EN 60332-1-2 EN 50265-2-1
IEC 60332-1 BS 4066-1 VDE 0482-265-2-1
IEC 60332-3-21 Cat A F/R
Bunched cables 40 minute burn test. 7.0 litres/metre of combustible material.
EN 60332-3-21 Cat A F/R
EN 50266-2-1 Cat A F/R
IEC 60332-3-22 Cat A
Bunched cables 40 minute burn test. 7.0 litres/metre of combustible material.
EN 60332-3-22 Cat A EN 50266-2-2 Cat A
IEC 60332-3A BS 4066 pt 3A VDE 0482-266-2-2 Cat A
IEC 60332-3-23 Cat B
Bunched cables 40 minute burn test. 3.5 litres/metre of combustible material.
EN 60332-3-23 Cat B EN 50266-2-3 Cat B
IEC 60332-3B BS 4066 pt 3B VDE 0482-266-2-3 Cat B
IEC 60332-3-24 Cat C
Bunched cables 20 minute burn test. 1.5 litres/metre of combustible material.
EN 60332-3-24 Cat C EN 50266-2-4 Cat C
IEC 60332-3C BS 4066 pt 3C VDE 0482-266-2-4 Cat C
IEC 60332-3-25 Cat D
Bunched cables 20 minute burn test. 0.5 litres/metre of combustible material.
EN 60332-3-25 Cat D
EN 50266-2-5 Cat D
Alternative Standard References
Fire Resistant Circuit Integrity Tests IEC 60331-21
Cables up to and including 0.6/1kV. 90 minutes minimum @ 750°C with fire.
IEC 60331-23
Data cables. 90 minutes @ 750°C with fire.
IEC 60331
VDE 0472 FE180
IEC 60331-25
Optical fibre cables. 90 minutes @ 750°C with fire.
IEC 60331-1 & 2
Cables up to and including 0.6/1kV. 120 minutes @ 830°C with fire & mechanical shock.
BS 6387 Cat C
Circuit integrity for 3 hours @ 950°C with fire.
BS 6387 Cat W
Circuit integrity for 30 minutes @ 650°C. 15 mins with fire, 15 mins with fire & water spray.
BS 6387 Cat Z
Circuit integrity for 15 minutes @ 950°C with fire & mechanical shock.
BS 8434-1 Standard
Circuit integrity for 30 minutes @ 850°C. 15mins fire, 15 mins with fire & water spray
BS 5839-1 Clause 26.2d
BS 8434-2 Enhanced
Circuit integrity for 2 hours @ 950°C. 60 mins fire & shock, 60 mins fire, shock & water spray.
BS 5839-1 Clause 26.2e
EN 50200 PH30
Circuit integrity for 30 minutes @ 850°C with fire and mechanical shock.
Similar to BS 8434-1 without the water spray test
EN 50200 PH60
Circuit integrity for 60 minutes @ 850°C with fire and mechanical shock.
EN 50200 PH120
Circuit integrity for 120 minutes @ 850°C with fire and mechanical shock.
cables
FS
FS
Halogen Gas Emission Tests
IEC 60754-1 cables
IEC 60754-2
cables
FS
IEC 61034-2
FS cables
Similar to BS 8434-2 without the water spray test
Alternative Standard References
Determination of halogen acid gas generation. Only suitable for cables with emissions of 5% and above. Not suitable for Low Smoke Halogen Free classification.
EN 50267-2-1
BS 6425-1
VDE 0482-267-2-1
Determination of the degree of acidity of gases evolved EN 50267-2-2 during combustion by measuring pH levels and conductivity. Suitable for Low Smoke Halogen Free classification.
BS 6425-2
VDE 0482-267-2-2
Alternative Standard References
Smoke Generation Tests
IEC 61034-1
IEC 60331-31
Test apparatus for measuring the smoke density of cables.
EN 61034-1
EN 50268-1
BS 7622-1
VDE 0482-1034-1
Test proceedure and requirements. Minimum of 60% light transmission.
EN 61034-2
EN 50268-2
BS 7622-2
VDE 0482-1034-2
www.fscables.com
sales@fscables.com
For additional FREE copies of 'the little red book', or if you would like one sent to a colleague, simply contact us using the methods below. Please provide us with the contact and company name, address, postcode and contact telephone number.
01727 840 841
www.fscables.com/littleredbook
littleredbook@fscables.com Text the word
CABLES to 65000
followed by your name & address
Texts are charged at your standard network rate. Your details are only used for catalogue dispatch and order fulfillment. They are not shared or disclosed with any third party.
www.fscables.com sales@fscables.com
OEM Sales: 01727 849 801 Contractor Sales: 01727 849 802 Wholesaler Sales: 01727 849 849
FS
FS
FS
cables
Great effort has been made to ensure the accuracy of the information in this booklet. However products may vary due to manufacturing changes, technical improvements and commercial factors. In particular, overall diameters and weights are given for guidance only and if critical, they should be confirmed at time of order.
Fax : 01727 840 842
FS
FS
cables
cables
FS
No part of this publication may be reproduced or replicated in any form without the express written permission of Caplink Ltd.
Tel: 01727 840 841
cables
FS
cables
All Trade Marks and Trade Names are acknowledged. Š Copyright Caplink Ltd 2010. All rights reserved.
cables
General Sales: 01727 840 841 Fax: 01727 840 842
FS
cables
FS Cables, Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX
cables
s
cables
S
FS
FS Cables Front Cover*:Layout 1
18/11/10
15:33
Page 1
the little
FS
red book
Issue 10
cables
the little red book
FS
cables
FS
FS
FS
FS
FS
Issue 10
FS Cables Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX
cables
cables
cables
cables
cables
flexible and FSspecialist FS cables cables
FS Cables
Tel: 01727 840 841 Fax: 01727 840 842 www.fscables.com sales@fscables.com
cables