'the little red book' Issue 10

Page 1

s

cables

S

FS

FS Cables Front Cover*:Layout 1

18/11/10

15:33

Page 1

the little

FS

red book

Issue 10

cables

the little red book

FS

cables

FS

FS

FS

FS

FS

Issue 10

FS Cables Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX

cables

cables

cables

cables

cables

flexible and FSspecialist FS cables cables

FS Cables

Tel: 01727 840 841 Fax: 01727 840 842 www.fscables.com sales@fscables.com

cables


How to Order:

Payment Options:

By phone

Apply for a credit account

01727 840 841

Please ask your sales contact or visit the website for an account application form

By fax

01727 840 842 By email

By payment card

sales@fscables.com

We accept most major credit, debit and purchasing cards

Our hours are

Mon-Fri 8am to 6pm

Delivery Options: •

Next working-day delivery is standard to mainland UK, free on orders over £100

No cut-off time for orders – if we can ship it, we will

Same-day deliveries, distance and time permitting

Express Delivery Options for Parcels and Small Drums: Pre 9.00am / Pre 10.30am / Pre 12pm and next working-day service available Pre 10.30am / Pre 12pm and next working-day service available Pre 12pm and next working-day service available Next working-day service only

2-3 day service – please check at time of order. Surcharges apply. Note pallet services differ slightly, with the earliest delivery option being Pre 10.30am.


Many of the cables listed on the following pages would be regarded as specialist within the electrical industry. We regard them as standard. To support this we hold many of them in stock for immediate despatch and in many cases, cut to the length you require – keeping your costs down and reducing the environmental impact through reduced wastage. With constant pressure to keep prices as low as possible it is essential to maintain quality and standards and this has become our mission. The products offered are designed to do the job – your job. Our commitment to service means you’ll receive goods where and when you need them. With stock items there is no order cut-off time, if we can ship it we will. Next working-day delivery to UK mainland is standard. For special and modified products we offer realistic lead times and sensible minimum order quantities. Many stock products can also be modified to meet specific requirements, for example armouring, oversheathing or duct grade for exterior use. Quantities on these can often be as low as 100m. Please see pages 152-153 for more information.

www.fscables.com

DATA

06

COAXIAL

28

HOME AUTOMATION HD

40

BUS

42

AUDIO

49

FIRE & SECURITY

54

LONDON UNDERGROUND

62

TELEPHONE

64

SIGNAL & CONTROL

72

POWER CABLES

96

MARINE, OIL & GAS

102

RUBBER & CRANE

118

ROBOTICS

124

HIGH TEMPERATURE

130

THERMOCOUPLE

138

SPIRAL

142

GLANDS

144

TOOLS

148

SPECIAL MANUFACTURE

152

TECHNICAL TABLES

154

COLOUR CODES

166


4

SERVICE & SUPPORT Same Day Dispatch There is no cut off time for orders received, if we can ship your order we will. For really urgent orders we can courier goods sameday into and around London, time permitting. Modern Warehousing Facility Over 55,000sq ft. of modern warehouse space featuring large, secure loading and unloading facilities and a full size weighbridge. Commitment to Stock Approximately 3000 product lines are held in stock for next working-day delivery, free on orders over £100. Dedicated Export Department Our export team FSC Global are on hand to handle overseas enquiries. Custom Manufacture If you need a cable manufactured to your own specification or standard – talk to us. This can range from a printed or coloured jacket, right down to composite cables containing multiple elements. Armouring and Over-Sheathing Over-sheathing or steel wire armouring (SWA) to an existing cable with short lead times and for quantities as low as 100m. Cut to Length

cables

FS

FS

We cut to length on many product lines meaning you only buy what you need – reducing both your costs and wastage. Order Call-Off Place an order and ‘call it off’ over time as required from our warehouse for just in time deliveries. This both fixes your costs and guarantees supply.

cables

How to find us cables

FS

FS cables

FS Cables are based on Alban Park in St. Albans near J3 of the A1(M) or J22 of M25. If using Sat-Nav please use the postcode AL4 0JJ. Full turn by turn directions are available on the website www.fscables.com/map

www.fscables.com

sales@fscables.com


5

HOW TO USE THIS CATALOGUE

Many of the products listed in this catalogue are available in Low Smoke Halogen Free (LSHF), duct grade or SWA versions. These products are clearly indicated on each page using this key: Low Smoke Halogen Free

Duct Grade

SWA

Low Smoke Halogen Free Low Smoke Halogen Free cables are those which emit minimal levels of toxic fumes and smoke in the event of fire. It does not refer specifically to one particular type of material. They are ideal for installations in confined areas such as computer rooms and other sensitive environments, or areas that may be difficult to evacuate in the event of fire such as airports, hospitals or tube stations. Standard PVC cables are made up of halogens which, when burnt, give off toxic gases such as hydrogen chloride. When exposed to water – moisture in the air or fire sprinkler systems for example, hydrogen chloride forms highly noxious and corrosive hydrochloric acid. Specifying Low Smoke Halogen Free (LSHF) cable goes a long way to reducing this risk.

3m³ smoke test to IEC 61034

Compared to standard PVC which emits around 28% acid gas, LSHF cables produce less than 0.5% HCl (Gases Evolved During Combustion BS EN 50267, IEC 60754-2). Visibility through smoke emission is measured through a 3m³ smoke test (pictured) to IEC 61034. Most LSHF cables produce very little smoke as opposed to standard PVC which gives off dense black smoke. Confusion still surrounds the terminology used to describe LSHF cables. While LSHF, LS0H, LSZH and 0HLS are the same, LSF (Low Smoke & Fume) is not. LSF covers data, control and flexible cables and is normally significantly inferior. LSF cables are often modified PVC compounds and can still emit up to 22% HCl. They should be regarded as only slightly better than PVC in the event of fire. The LSF cables in this catalogue can be regarded as better than standard PVC but are not halogen free. If you are unsure of what you are buying, ask for written confirmation that the cable is LSHF throughout. At FS Cables, when you select LSHF, you can be confident you are buying a high quality Low Smoke Halogen Free cable.

FS

cables

FS

FS

FS

FS

FS

cables

FS

cables

FS Where all the products on a page are LSHF they are indicated with this header.

Duct Grade Duct grade cables feature a tough, water resistant polyethylene (PE) jacket normally over the standard jacket. They are suited for external installations where the cable may be run through ducts or clipped to buildings. They also offer excellent UV resistance.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

SWA cables are ideal for fixed external installations or direct burial or where mechanical protection is required. The cable features protective steel armour wires and a PE, external grade PVC or Low Smoke Halogen Free outer jacket over the duct grade cable above.

cables

SWA

cables

cables


6 Belden No.

1048AH 1215A 1502RHDA 1588AH 3076FHA 3077FHA 3078FHA 3079AHDA 3079E 3082A 3083AA 3084A 3085AA 3102A 3119A 7701H 7702H 7703H 7704H 8102H 8103H 8104 8105 8106H 8107 8108H 8110 8112 8115 8118 8125 8132H 8133H 8162HL 8163HL 8164H 8166 8167H 8168 8170 8175 8178 8185 cables 8205HL 8312 8325 8345 8355 8442HL 8444H 8451HL 8471HDAL cables

FS

FS

cables

FS

FS cables

DATA Belden Page Finder Page

21 22 46 24 42 42 42 45 45 43 43 43 43 44 44 44 44 44 44 17 17 17 17 17 17 17 17 17 17 17 17 56 56 18 18 18 18 18 18 18 18 18 18 7 DS DS DS DS 7 7 8 7, 44, 57

Belden No.

Page

8473HL 7 8618 9 8719HL 8 8720H 8 8723HDAL 12, 56, 60, 61 8728HL 12 8760HDL 8, 60 8761HDL 8 8762HDL 8 8769 13 8770HL 9 8771H 9 8772H 9 8773 13 8774H 13 8775 13 8776 13 8777HDAL 13, 56, 60, 61 8778HL 13 9156H 7 9182H 22 9207H 22 9248 DS 9272H 22 9363 21 9365 21 9368HL 19 9402HL 19 9418HL 10 9463H 22 9491 7 9501HDL 11, 60 9502HL 11 9503HDL 11, 60 9504HDL 11, 60 9505HL 11 9506HL 11, 60 9507H 11 9508HL 11 9509 11 9510HL 11 9515H 11 9519HL 11 9525HL 11 9533L 10 9534HL 10 9535L 10 9536HL 10 9537 10 9538HL 10 9539 10 9891 22

Belden No.

Page

9540HL 10 9541HL 10 9542 10 9543 10 9544 10 9545 10 9546 10 9550 11 9688H 22 9696 DS 9728H 14 9729HDAL 14, 60, 61 9730HL 14 9731H 14 9732 14 9733 14 9734 14 9735 14 9736 14 9737 14 9738 14 9740HL 7 9744H 7 9750H 7 9767 13 9768H 13 9769 13 9773H 19 9774H 19 9829H 20 9830 20 9831 20 9832 20 9833 20 9834 20 9835 20 9836 20 9837 20 9838 20 9839 20 9841HDAL 15, 45 9842HDAL 15, 56, 60, 61 9843H 15 9844H 15 9860 22 9873HL 19 9874 19 9875 19 9876 19 9877 19 9879 19 9880 22

Belden No.

Page

9901H 9907H 9913 9925 9927 9929 9931 9932 9933 9934 9935 9936 9937 9938 9939 9940 9941 9942 9943 9944 9945 9946 9947 9948 9949 9950 9990 9991 YM29560 YR47205

22 22 DS 16 16 16 16 16 16 16 16 16 16 16 20 20 20 20 20 20 20 20 20 20 20 20 DS DS 45 43

Key

H = LSHF D = DUCT A = SWA L = LSF Details of cables listed as DS are available on a separate datasheet. LSF versions are available from stock where indicated In line with the rest of the industry our LSF cables are a modified PVC. If you need halogen free cables please specify LSHF.

FSC stock a wide range of genuine Belden cables and cost effective alternatives with PVC, Low Smoke Halogen Free and duct grade jackets. Armoured versions are also available from stock.

www.fscables.com

sales@fscables.com


7

Unscreened Pairs DATA Unscreened Paired Data Cable N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

General purpose unscreened single and multipair cables with a small outer diameter, frequently used in audio, bus, data, security and instrumentation applications. These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - Single Pair

Technical Information

Tinned copper stranded conductor, PVC insulation on

Voltage Rating:

22AWG -16AWG: 300V 14AWG:

standard cable, twisted into a pair, PVC sheath.

600V

CE: 450/750V† Colour Code:

Part No.

2201PUYL 2201PUYH 2001PUYL 2001PUYH 1801PUYL 1801PUYH 1601PUYL 1601PUYH 1401PUYL 1401PUYH

Alt. to Belden

No. of Pairs

AWG

CSA mm2

Weight kg/km

O/D mm

Capacitance C/C pF/m

8442 LSHF 8205 LSHF 9740 LSHF 8471 LSHF 8473 LSHF

1 1 1 1 1 1 1 1 1 1

22(7) 22(7) 20(7) 20(7) 18(16) 18(16) 16(19) 16(19) 14(42) 14(42)

0.35 0.35 0.56 0.56 0.79 0.79 1.34 1.34 2.01 2.01

23 23 26 26 37 37 56 56 89 89

4.5 4.5 5.0 5.0 6.0 6.0 7.0 7.0 8.5 8.5

99 99 81 81 84 84 108 108 108 108

Construction - Two & Three Pair

Technical Information

Tinned copper stranded conductor, PVC insulation, cores twisted into pairs, pairs laid together, clear tape, PVC sheath.

Voltage Rating:

9744 NH 9156 NH 9750 LSHF

No. of Pairs

AWG

2 2 3 3

22(7) 18(16) 20(7) 20(7)

Colour Code: CSA mm2

0.35 0.79 0.56 0.56

O/D mm

Capacitance C/C pF/m

39 71 67 67

6.2 8.5 7.6 7.6

84 84 80 80

Construction - Multicore

Technical Information

Tinned copper stranded conductor, PVC insulation, cores laid up, clear tape, PVC sheath.

Voltage Rating:

AWG

FS cables

CSA mm2

Weight kg/km

Chart 2 page 166 O/D mm

Capacitance C/C pF/m

FS

FS

FS

FS

9491

3

22(7)

0.35

32

4.9

85

8444 NH

4

22(7)

0.35

34

5.1

111

cables

2204CUYH

No. of Cores

FS

CE: 450/750V

cables

2203CUY

Alt. to Belden

FS

cables

300V

2204CUYH

Colour Code: Part No.

FS

Weight kg/km

cables

2202PUYH 1802PUYH 2003PUY 2003PUYH

Alt. to Belden

22AWG -16AWG: 300V 14AWG: 600V CE: 450/750V† Chart 3 page 166 cables

Part No.

1601PUYL

22AWG -18AWG: Black & red 16AWG -14AWG: Black & white

† Applies to CE marked FSC branded stock only

Low Smoke Halogen Free

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


8

DATA Screened Single Pair

Single Pair ScreenedXLPE/Cu/LSHF Data Cable Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV General purpose foil screened single pair cables with a small outer diameter, frequently used in audio, data and instrumentation applications. Polyethylene insulation results in lower signal loss than standard PVC insulation. These cables can also be supplied with PE sheaths for running in ducts or in SWA versions for direct burial. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - Screened Single Pair

Technical Information

Tinned copper conductor, polyethylene insulation,

Voltage Rating:

twisted pair, aluminium/polyester foil screen, tinned

300V

16AWG -14AWG:

600V

CE: 450/750V†

copper drain wire, PVC sheath. On duct grade cables

1601POFPL

22AWG -18AWG:

Temperature Rating: 22AWG - 18AWG: +60°C

an additional UV stable LDPE jacket is put over the

16AWG - 14AWG: +80°C

standard PVC cables to give a high degree of weather resistance.

UL Style*:

2092

Colour Code:

Black & clear (Black & white on LSHF cables)

Part No.

1801POFPD cables

FS

FS

Alt. to Belden

No. of Pairs

2201POFPL 8761 2201POFPH LSHF 2201POFPD DUCT 2001POFPL 8762 2001POFPH LSHF 2001POFPD DUCT 1801POFPL 8760 1801POFPH LSHF 1801POFPH06 VIOLET 1801POFPD DUCT 1601POFPL 8719 1601POFPH LSHF 1401POFP 8720 1401POFPH LSHF

1 1 1 1 1 1 1 1 1 1 1 1 1 1

AWG

22(7) 22(7) 22(7) 20(7) 20(7) 20(7) 18(16) 18(16) 18(16) 18(16) 16(19) 16(19) 14(19) 14(19)

CSA mm2

0.35 0.35 0.35 0.56 0.56 0.56 0.79 0.79 0.79 0.79 1.34 1.34 1.92 1.92

cables

cables

4.6 4.6 6.2 5.1 5.1 6.5 6.0 6.0 6.0 7.6 7.9 7.9 9.0 9.0

Technical Information

Tinned copper conductors, polypropylene insulation,

Voltage Rating:

copper drain wire, PVC sheath.

2201POFRL 2201POFRH

Alt. to Belden

8451 LSHF

No. of Pairs

1 1

AWG

22(7) 22(7)

CSA mm2

0.35 0.35

Capacitance pF/m C/C

C/S

79 79 79 89 89 89 79 79 79 79 75 75 79 79

154 154 154 161 161 161 144 144 144 144 144 144 154 154

300V CE: 450/750V†

twisted pair, aluminium/polyester foil screen tinned

Part No.

FS

25 25 27 35 35 38 45 45 45 48 84 84 109 109

O/D mm

Construction - Miniature 22AWG

cables

FS

Weight kg/km

Temperature Rating:

+75°C

Nominal Impedance:

45 Ohms

Colour Code:

Black & red

Weight kg/km

20 20

O/D mm

3.4 3.5

Capacitance pF/m C/C

C/S

111 111

220 220

† Applies to CE marked FSC branded stock only *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

Duct Grade

www.fscables.com

sales@fscables.com


9

Screened Triple DATA Three Core Overall Screened Data Screened, Cable N2XCH-FE180/E90: XLPE/Cu/LSHF Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV For use as audio or instrumentation wiring.

Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 22AWG, 20AWG & 18AWG

Technical Information

Tinned copper conductor, polyethylene insulation, cores

Voltage Rating:

300V CE: 450/750V†

laid up, aluminium/polyester foil screen, tinned copper drain wire, PVC sheath.

Temperature Rating: UL Style*:

+60°C

Colour Code:

Black, red & clear

2093

1803COFPL Part No.

Alt. to Belden

No. of Cores

AWG

CSA mm2

Weight kg/km

O/D mm

Capacitance pF/m C/C C/S

3 3 3 3 3 3 3

22(7) 22(7) 22(7) 20(7) 20(7) 18(16) 18(16)

0.35 0.35 0.35 0.56 0.56 0.79 0.79

35 35 35 42 42 56 56

5.1 5.1 5.1 5.6 5.6 6.3 6.3

75 75 75 89 89 79 79

2203COFP 8771 2203COFPH LSHF 2203COFPH06 VIOLET 2003COFP 8772 2003COFPH LSHF 1803COFPL 8770 1803COFPH LSHF

134 134 134 167 167 157 157

Construction - 16AWG

Technical Information

Tinned copper conductor, polyethylene insulation,

Voltage Rating:

600V

cores laid up, aluminium/polyester foil screen, tinned

Temperature Rating:

+60°C

copper drain wire, PVC sheath.

UL Style:

2107

Colour Code:

Black, red & clear

No. of Cores

AWG

CSA mm2

Weight kg/km

O/D mm

1603COFP

8618

3

16(19)

1.34

96

8.3

Capacitance pF/m C/C C/S

85

2203COFPH06

FS

FS

FS

cables

FS

FS

FS

FS

FS

151

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

† Applies to CE marked FSC branded stock only

cables

Alt. to Belden

cables

Part No.

cables


10

DATA Overall Screened Multicores

Overall Screened Multicored Data Screened, Cable RS232 N2XCH-FE180/E90: XLPE/Cu/LSHF Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Uses include RS232, instrumentation and sound applications where balanced lines are not required. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 24AWG

Technical Information - 24AWG & 18AWG

Tinned copper conductor 24(7) AWG, 0.22mm2, PVC insulation. Cores laid up, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), PVC sheath.

Voltage Rating:

300V CE: 450/750V† Temperature Rating: +80°C Capacitance: Up to 8 core: Core to core 108pF/m, Core to screen 213pF/m Above 8 core: Core to core 98pF/m, Core to screen 180pF/m UL Style*: 2464 Colour Code: Up to 10 core Chart 1 page 166 Above 10 core Chart 2 page 166

2415COFYL

1804COFYL cables

FS

Part No.

Alt. to Belden

2403COFYL 2404COFYL 2404COFYH 2405COFYL 2406COFYL 2406COFYH 2407COFY 2408COFYL 2408COFYH 2409COFY 2410COFYL 2410COFYH 2415COFYL 2415COFYH 2420COFY 2425COFY 2430COFY 2440COFY 2450COFY

9533 9534 LSHF 9535 9536 LSHF 9537 9538 LSHF 9539 9540 LSHF 9541 LSHF 9542 9543 9544 9545 9546

No. of Cores

3 4 4 5 6 6 7 8 8 9 10 10 15 15 20 25 30 40 50

Weight kg/km

O/D mm

26 33 33 35 42 42 45 49 49 60 61 61 83 83 104 139 152 195 238

4.2 4.7 4.7 4.8 5.3 5.3 5.3 5.7 5.7 6.2 6.2 6.2 7.3 7.3 8.0 8.6 9.7 10.9 12.5

Construction - 18AWG

FS cables

cables

FS

Tinned copper conductor 18(19) AWG, 0.79mm2, PVC insulation, colour chart 1, page 166. Cores laid up, overall aluminium/polyester foil screen, tinned copper drain wire (20AWG), PVC sheath. Part No.

Alt. to Belden

No. of Cores

Weight kg/km

O/D mm

1804COFYL 1804COFYH

9418 LSHF

4 4

78 78

6.2 6.2

† Applies to CE marked FSC branded stock only

A full range of 22AWG cored cables is available from stock with LSHF and duct grade versions available to order. *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

FS cables

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


11

Overall Screened Multipairs DATA Overall Screened Multipair Data Cable RS232

Widely used for computers, point of sale, control systems and RS232 applications. This is a general purpose overall screened twisted paired cable. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 24AWG

Technical Information - 24AWG & 22AWG

Tinned copper conductor 24(7) AWG,

Voltage Rating:

0.22mm2, PVC insulation. Twisted into

Temperature Rating: Capacitance:

pairs, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), PVC sheath.

UL Style*: Colour Code: Part No.

Alt. to Belden

O/D mm

1 1 1 2 2 3 3 3 4 4 4 5 5 6 6

21 21 44 32 32 49 49 66 54 54 72 66 66 72 72

3.9 3.9 6.2 5.6 5.6 5.9 5.9 8.1 6.7 6.7 8.9 7.4 7.4 7.4 7.4

Part No.

Alt. to Belden

2406POFYD DUCT 2407POFY 9507 2407POFYH LSHF 2408POFYL 9508 2408POFYH LSHF 2409POFY 9509 2410POFYL 9510 2410POFYH LSHF 2415POFY 9515 2415POFYH LSHF 2419POFYL 9519 2419POFYH LSHF 2425POFYL 9525 2425POFYH LSHF 2450POFY 9550

No. of Pairs

Weight kg/km

O/D mm

6 7 7 8 8 9 10 10 15 15 19 19 25 25 50

93 80 80 97 97 104 119 119 160 160 192 192 243 243 460

9.6 7.5 7.5 8.2 8.2 8.5 9.3 9.3 10.5 10.5 11.4 11.4 12.8 12.8 18.0

Construction - 22AWG

2206POFY

FS

Tinned copper conductor 0.34mm2, PVC insulation. Twisted into pairs, overall aluminium/polyester foil screen,

FS

cables

Weight kg/km

2403POFYD

cables

2401POFYL 9501 2401POFYH LSHF 2401POFYD DUCT 2402POFYL 9502 2402POFYH LSHF 2403POFYL 9503 2403POFYH LSHF 2403POFYD DUCT 2404POFYL 9504 2404POFYH LSHF 2404POFYD DUCT 2405POFYL 9505 2405POFYH LSHF 2406POFYL 9506 2406POFYH LSHF

No. of Pairs

300V CE: 450/750V† +80°C 1 Pair: Core to core 131pF/m Core to screen 243pF/m 24AWG: Core to core 98pF/m Core to screen 164pF/m 22AWG: Core to core 114pF/m approx Core to screen 206pF/m approx 2464 Chart 3 page 166

tinned copper drain wire (24AWG), PVC sheath. Part No.

Weight kg/km

22 22 22 22 22 22 22 22 22

2 3 4 5 6 9 11 15 19

38 50 71 81 88 123 160 190 234

† Applies to CE marked FSC branded stock only

O/D mm

FS

FS

FS

FS

5.8 6.1 6.7 cables 7.4 7.9 9.1 9.9 10.9 12.8

cables

cables

No. of Pairs

cables

2202POFY 2203POFY 2204POFY 2205POFY 2206POFY 2209POFY 2211POFY 2215POFY 2219POFY

AWG

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

Duct Grade

Tel: 01727 840 841

Fax : 01727 840 842

FS

cables

FS cables


12

DATA Individually Screened Two Pair

Individually Screened Two Pair Data Cable 22AWG N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Used extensively in the security industry for CCTV applications including telemetry. Also suitable for computer and instrumentation applications where it is important to provide a high level of screening from external sources, together with low levels of cross talk between pairs. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - Individually Screened

Technical Information

Tinned copper conductor 22(7) AWG 0.35mm2,

Voltage Rating:

polypropylene insulation, twisted into pairs, each pair

2202PIFR

Temperature Rating: Nominal Impedance: Capacitance:

aluminium/polyester foil screened, common tinned copper drain wire (24AWG), PVC sheath. The duct grade version has a black UV stable polyethylene sheath over the standard PVC cable to provide a high

Colour Code:

300V CE: 450/750V† +60°C 45 Ohms Core to core 115pF/m Core to screen 203pF/m Red/Black & Green/White

degree of weather resistance, while the armoured version is protected by heavy galvanised steel wires and an external grade sheath. Part No.

2202PIFR 2202PIFRW 2202PIFRL 2202PIFRH 2202PIFRH06 2202PIFRD 2202PIFRA

Alt. to Belden

8723 WHITE LSF LSHF VIOLET DUCT SWA

No. of Pairs

AWG

2 2 2 2 2 2 2

22(7) 22(7) 22(7) 22(7) 22(7) 22(7) 22(7)

Weight kg/km

O/D mm

32 32 32 32 32 50 210

4.2 4.2 4.2 4.2 4.2 6.2 9.8

2202PIFRA cables

FS

Construction - Individually and Overall Screened

Technical Information

Tinned copper conductor 22(7) AWG 0.35mm2,

Voltage Rating:

polypropylene insulation, twisted into pairs, each pair Temperature Rating: Nominal Impedance: Capacitance:

individually screened with aluminium/polyester foil and 24AWG tinned copper drain wire, overall aluminium/ polyester foil and 24AWG tinned copper drain wire,

FS cables

PVC sheath.

Part No.

2202PTFRL 2202PTFRH

UL Style: Colour Code:

300V CE: 450/750V† +60°C 45 Ohms Core to core 115pF/m Core to screen 203pF/m 2717 Red/Black & Green/White

Alt. to Belden

No. of Pairs

AWG

Weight kg/km

O/D mm

8728 LSHF

2 2

22(7) 22(7)

42 42

5.2 5.2

cables

FS

† Applies to CE marked FSC branded stock only

FS cables

Low Smoke Halogen Free

Duct Grade

SWA

www.fscables.com

sales@fscables.com


13

Individually Screened Multipairs DATA Individually Screened Multipair Data Cable 22AWG

These cables are used extensively within security, computer and instrumentation applications. Many sizes are also used within the audio field as snake cables where the individual screening of pairs reduces cross talk. The 3 pair version is particularly popular within the security industry for CCTV and access control systems. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 22AWG

Technical Information

Tinned copper conductor 22(7) AWG, 0.35mm2.

Voltage Rating:

Polypropylene insulated. Twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (24AWG), PVC sheath.

Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:

Part No.

Alt. to Belden

No. of Pairs

AWG

300V CE: 450/750V† +80°C 50 Ohms Core to core 98pF/m Core to screen 180pF/m 2919 Chart 3 page 166

Weight kg/km

2203PIFRD

O/D mm

3

22(7)

70

7.0

LSHF

3

22(7)

70

7.0

2203PIFRA

SWA

3

22(7)

330

11.1

2203PIFRD

DUCT

3

22(7)

96

8.6

2206PIFRL

8778

6

22(7)

123

9.2

2206PIFRH

LSHF

6

22(7)

123

9.2

2209PIFR

8774

9

22(7)

177

10.6

2209PIFRH

LSHF

9

22(7)

177

10.6

2211PIFR

8775

11

22(7)

201

11.8

2212PIFR

9768

12

22(7)

226

12.1

2212PIFRH

LSHF

12

22(7)

226

12.1

2215PIFR

8776

15

22(7)

290

13.9

2217PIFR

9769

17

22(7)

331

14.7

2219PIFR

8769

19

22(7)

348

15.3

2227PIFR

8773

27

22(7)

502

18.0

2237PIFR

9767

37

22(7)

739

20.3

2206PIFRL

FS

FS

FS

cables

FS

FS

FS

FS

FS

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

Duct Grade

Tel: 01727 840 841

SWA

Fax : 01727 840 842

cables

cables

cables

cables

† Applies to CE marked FSC branded stock only

cables

8777

2203PIFRH

cables

2203PIFRL

cables


14

DATA Individually Screened Multipairs

Individually Screened Multipair Data Cable 24AWG Low Capacitance RS422 For RS422 connection and any other application requiring both low capacitance and excellent isolation between pairs. Used for CAD/CAM and many other industrial applications with high data rates. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

Technical Information

Construction - 24AWG

Voltage Rating:

Tinned copper conductor 24(7) AWG 0.22mm , 2

foam polyolefin insulation. Twisted into pairs, each

2402PIFFD

The insulation and sheath materials are replaced

pair aluminium/polyester foil screened, tinned copper drain wire (24AWG), PVC sheath.

Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:

2406PIFF

cables

FS

FS

Part No.

Alt. to Belden

No. of Pairs

300V CE: 450/750V† +60°C 100 Ohms Core to core 41 pF/m Core to screen 76 pF/m 2463 Chart 3 page 166

Weight kg/km

O/D mm

2402PIFFL

9729

2

66

6.7

2402PIFFH

LSHF

2

66

6.7

2402PIFFD

DUCT

2

79

10.2

2402PIFFA

SWA

2

178

12.6

2403PIFFL

9730

3

80

8.5

2403PIFFH

LSHF

3

80

8.5

2404PIFF

9728

4

97

9.2

2404PIFFH

LSHF

4

97

9.2

2406PIFF

9731

6

137

10.7

2406PIFFH

LSHF

6

137

10.7

2409PIFF

9732

9

203

12.4

2411PIFF

9733

11

226

14.6

2412PIFF

9734

12

242

14.6

2415PIFF

9735

15

300

16.3

2417PIFF

9736

17

326

17.1

2419PIFF

9737

19

348

17.1

2427PIFF

9738

27

557

20.3

cables

† Applies to CE marked FSC branded stock only cables

FS

Some of the above cables are also available in armoured, duct grade or Low Smoke Halogen Free versions even where not listed. Please call for details. * UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

FS cables

Low Smoke Halogen Free

Duct Grade

SWA

www.fscables.com

sales@fscables.com


15

Overall Foil & Braid Screened Pairs DATA

Overall Foil & Braid Screened Paired Data Cable RS485 Capacitance N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire24AWG Resistant (IECLow 60331) LSHF Power Cable – 0.6/1kV Designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 24AWG

Technical Information

Tinned copper conductor 24(7) AWG 0.22mm2,

Voltage Rating:

polyethylene insulation. Twisted into pairs, overall aluminium/polyester foil screened, tinned copper drain wire (24AWG), overall tinned copper braid (90%). PVC sheath.

Part No.

Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:

Alt. to Belden

No. of Pairs

300V CE: 450/750V† +80°C 120 Ohms Core to core 42 pF/m Core to screen 76 pF/m 2919 Chart 5 page 166

Weight kg/km

O/D mm

2401POHPL>

9841

1

64

5.8

2401POHPD

DUCT

1

92

8.4

2401POHPH

LSHF

1

64

5.8

2401POHPA

SWA

1

192

9.6

2402POHPL+

9842

2

95

8.6

2402POHPD

DUCT

2

118

11.1

2402POHPH

LSHF

2

95

8.6

2402POHPA

SWA

2

251

12.5

3

108

9.2

LSHF

3

108

9.2

2404POHP

9844

4

125

9.9

2404POHPH

LSHF

4

125

9.9

2402POHPD

FS

FS

FS

FS

cables

cables

9843

cables

2403POHP 2403POHPH

2401POHPH

cables

† Applies to CE marked FSC branded stock only

> Single pair 2401POHPL is supplied with blue & white cores (Western Electric colour code, page 166) as standard or black & white cores as special order. Please specify if you have a preference at time of order.

FS

FS

FS

cables

FS

2402POHP is an alternative to Allen Bradley type 1747CD * UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or

cables

+

approved by UL. If you require UL approved versions please tell us when you first enquire. Low Smoke Halogen Free

Duct Grade

SWA

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


16

DATA Overall Foil & Braid Screened Cores

Overall Foil & Braid Screened Cored Data Cable RS232 & RS423 A range of high performance cables for use over extended distances at high data rates for RS232 and RS423 applications. Also well suited to industrial measurement where low signal distortion is required. These cables are widely used in CAD/CAM applications.

Technical Information

Construction - 24AWG Tinned copper conductor 24(7) AWG, 0.22mm , foam 2

polyolefin insulation. Cores laid up, overall

2405CODF

aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath.

Part No.

cables

FS

Voltage Rating: Temperature Rating: Capacitance:

Alt. to Belden

No. of Cores

UL Style*: Colour Code:

Weight kg/km

300V +80째C Core to core 40 pF/m Core to screen 72 pF/m 2919 Up to 10 core Chart 1 page 166 Above 10 core Chart 2 page 166

O/D mm

2402CODF

N/A

2

33

4.7

2403CODF

9925

3

38

5.5 5.8

2404CODF

9927

4

45

2405CODF

9929

5

51

6.3

2406CODF

9931

6

58

6.7

2407CODF

9932

7

62

6.8

2408CODF

9933

8

68

7.1 7.6

2409CODF

9934

9

77

2410CODF

9935

10

83

7.8

2415CODF

9936

15

107

8.9

2425CODF

9937

25

165

11.3

2437CODF

9938

37

207

12.7

FS cables

cables

FS

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

FS cables

www.fscables.com

sales@fscables.com


17

Overall Foil & Braid Screened Pairs DATA Overall Foil & Braid Screened Paired Data Cable RS232 & RS422

A range of high performance cables for use over extended distances at high data rates for RS232 and RS422 applications. Also well suited to industrial measurement applications where low signal distortion is required. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 24AWG

Technical Information

Tinned copper conductor 24(7) AWG, 0.22mm2,

Voltage Rating:

foam polyolefin insulation. Twisted into pairs, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath.

Part No.

Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:

300V CE: 450/750V† +80°C 100 Ohms Core to core 41 pF/m Core to screen 72 pF/m 2919 Chart 5 page 166

Weight kg/km

2402PODF

8102

2

61

6.8

2402PODFH

LSHF

2

61

6.8

2403PODFL

8103

3

71

7.1

2404PODF

8104

4

80

7.6

2405PODF

8105

5

89

7.9

2406PODF

8106

6

104

8.6

2406PODFH

LSHF

6

104

8.6

2407PODF

8107

7

106

8.6

2408PODF

8108

8

118

9.3

2408PODFH

LSHF

8

118

9.3

2410PODF

8110

10

150

10.9

2412PODF

8112

12.5+

165

11.8

2415PODF

8115

15

196

12.6

2418PODF

8118

18

235

13.6

2419PODF

N/A

19

248

13.6

2425PODF

8125

25

297

16.1

FS

FS

cables

FS

FS

FS

FS

FS

Twelve pairs plus one conductor. *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire. Low Smoke Halogen Free

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

+

FS

cables

† Applies to CE marked FSC branded stock only

O/D mm

cables

No. of Pairs

cables

Alt. to Belden

2406PODF

cables


18

DATA Individual & Overall Screened Multipairs

Individual & Overall Screened Multipair Data Cable 24AWG RS422 Low Capacitance Designed for RS422 data connections, this cable combines low capacitance insulation with very high levels of screening to provide high speed, interference free, data transmission. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Technical Information

Construction - 24AWG Tinned copper conductor 24(7) AWG 0.22mm , foam 2

polyolefin insulation. Twisted into pairs, each pair

2402PTMFH

individually aluminium/polyester foil screened with an overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid

cables

FS

Alt. to Belden

2402PTMFL

8162

2402PTMFH

LSHF

Temperature Rating: Nominal Impedance: Capacitance: UL Style*: Colour Code:

(65%). PVC sheath. Part No.

Voltage Rating:

No. of Pairs

300V CE: 450/750V† +60°C 100 Ohms Core to core 41 pF/m Core to screen 72 pF/m 2493 Chart 3 page 166

Weight kg/km

O/D mm

2

92

8.7

2

92

8.7

2403PTMFL

8163

3

104

9.1

2403PTMFH

LSHF

3

104

9.1

2404PTMF

8164

4

121

9.8

2404PTMFH

LSHF

4

121

9.8

2406PTMF

8166

6

150

11.3

2407PTMF

8167

7

158

11.3

2407PTMFH

LSHF

7

158

11.3

2408PTMF

8168

8

177

12.0

2410PTMF

8170

10

245

15.0

2415PTMF

8175

15

325

17.0

2418PTMF

8178

18

354

17.5

2425PTMF

8185

25

522

21.0

FS cables

cables

FS

FS cables

† Applies to CE marked FSC branded stock only *UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


19

Individually Screened Multipairs DATA Individually Screened Multipair Data Cable 20AWG & 18AWG N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Widely used in monitoring, computer, instrumentation and audio applications where the individually screened pairs reduce cross talk. Reduced losses are achieved through the use of 20AWG or 18AWG conductors making this cable ideal for long runs. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - 20AWG

Technical Information

2 Pair - Tinned copper conductor 20(7)AWG, 0.56mm2, PVC insulated, twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (22AWG). PVC sheath.

Voltage Rating:

Multipair - Tinned copper conductor 20(7)AWG, 0.56mm2, polypropylene insulated. Twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (22AWG), PVC sheath.

Part No.

Alt. to Belden

No. of Pairs

Weight kg/km

Temperature Rating: Nominal Impedance: UL Style*: Colour Code:

O/D mm

300V CE: 450/750V† +60°C 45 Ohms+ 2pair: 2464 Above 2pair: 2919 2pair: Red/Black & Green/White Above 2pair: Chart 3 page 166

2009PIFP

Capacitance in pF/m C/S

C/C

2002PIFYL 2002PIFYH 2003PIFPL 2003PIFPH 2006PIFP 2009PIFP 2011PIFP 2012PIFP 2015PIFP

9402 LSHF 9873 LSHF 9874 9875 9876 9877 9879

2 2 3 3 6 9 11 12 15

76 76 104 104 182 270 302 322 384

7.6 7.6 8.4 8.4 10.9 13.6 15.2 15.2 17.0

180 180 98 98 98 98 98 98 98

Construction - 18AWG

Technical Information

2 Pair - Tinned copper conductor 18(19)AWG, 0.96mm2, PVC insulated, twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (20AWG). PVC sheath.

Voltage Rating:

Part No.

Alt. to Belden

No. of Pairs

Weight kg/km

Colour Code:

O/D mm

Capacitance in pF/m C/S

C/C

1802PIFYL 1802PIFYH 1803PIFP 1803PIFPH 1806PIFP 1806PIFPH

9368 LSHF 9773 LSHF 9774 LSHF

2 2 3 3 6 6

103 103 139 139 259 259

9.6 9.6 10.3 10.3 14.3 14.3

187 187 98 98 98 98

FS

FS

FS

FS

FS

FS

FS

FS

335 335cables 180 180 180 180

+

cables

cables

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire.

cables

† Applies to CE marked FSC branded stock only

1802PIFYL

cables

Multipair - Tinned copper conductor 18(19)AWG, 0.96mm2, polypropylene insulated. Twisted into pairs, each pair aluminium/polyester foil screened, tinned copper drain wire (20AWG), PVC sheath.

300V CE: 450/750V† +60°C 45 Ohms+ 2pair: 2464 Above 2pair: 2919 2pair: Black/Red Above 2pair: Chart 3 page 166

cables

Temperature Rating: Nominal Impedance: UL Style:

312 312 180 180 180 180 180 180 180

Impedence figure not applicable on two pair version

Low Smoke Halogen Free

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


20

DATA Overall Foil & Braid Screened Pairs & Cores

Overall Foil & Braid Screened Data Cables RS232 & RS422 A range of high performance cables for use over extended distances at high data rates for RS232 applications. They are also well suited to industrial measurement where low signal distortion is required. The 24AWG foil & braid twisted paired cable runs over RS232 & RS422 protocols. Excellent dual screening enables this cable to carry signals over long distances with minimum distortion. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke. Construction - 24AWG

2402PODP

Tinned copper conductor 24(7) AWG, 0.22mm2, polyethylene insulation. Twisted into pairs, overall aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath. Part No.

2402PODP 2402PODPH 2403PODP 2404PODP 2405PODP 2406PODP 2407PODP 2409PODP 2410PODP 2412PODP 2418PODP 2425PODP

Weight kg/km

O/D mm

9829 LSHF 9830 9831 9832 9839 9833 9834 9835 9836 9837 9838

2 2 3 4 5 6 7 9 10 12 18 25

61 61 70 79 84 97 103 130 140 155 225 295

7.4 7.4 7.7 8.4 8.6 9.3 9.4 10.6 11.5 11.8 14.4 17.1

Tinned copper conductor 22(7) AWG, 0.35mm2, semi rigid PVC insulation. Cores laid up, overall. Aluminium/polyester foil screen, tinned copper drain wire (24AWG), overall tinned copper braid (65%). PVC sheath

Part No.

FS cables

cables

FS

FS cables

2203CODY 2204CODY 2205CODY 2206CODY 2207CODY 2208CODY 2209CODY 2210CODY 2215CODY 2225CODY 2237CODY 2250CODY

UL Style*: Colour Code:

300V +80째C 100 Ohms Core to core 51 pF/m Core to screen 90 pF/m 2919 Chart 5 page 166

No. of Pairs

cables

FS

Technical Information Voltage Rating: Temperature Rating: Nominal Impedance: Capacitance:

Alt. to Belden

Construction - 22AWG

2209CODY

The insulation and sheath materials are replaced

Technical Information Voltage Rating: Temperature Rating: Nominal Impedance: Capacitance: Up to 5core -

300V +80째C 100 Ohms Core to core 121 pF/m, Core to screen 220 pF/m Above 5core -Core to core 115 pF/m Core to screen 207 pF/m UL Style*: 2464 Colour Code: Up to 10 core: Chart 1 page 166 Above 10 core: Chart 2 page 166

Alt. to Belden

No. of Cores

Weight kg/km

9939 9940 9941 9942 9943 9944 9945 9946 9947 9948 9949 9950

3 4 5 6 7 8 9 10 15 25 37 50

41 48 55 63 65 74 85 94 130 189 238 348

O/D mm

5.1 5.5 5.8 6.2 6.3 6.6 7.1 7.6 8.6 10.4 11.7 14.1

*UL style numbers are given for cross reference purposes only. Not all the cables on this page are tested to or approved by UL. If you require UL approved versions please tell us when you first enquire. Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


21

Instrumentation, Process Control & PLTC DATA Instrumentation, Process control & PLTC

Industrial process control and instrumentation cables suitable for use in a wide variety of industries from nuclear energy generation to security and access control. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - Individually and Overall Screened Pairs Plain copper conductor 18(7) AWG 0.88mm2, Low Smoke Halogen Free insulation with a nylon skin. Conductors twisted into pairs, black and white numbered pairs, each pair individually aluminium/polyester foil

1802PTFNH

screened with a 20(7) AWG tinned copper drain wire, pairs laid up with isolated screens. Overall screen is aluminium/polyester foil screen with 20(7) AWG tinned copper drain wire. Low Smoke Halogen Free sheath. Part No.

1802PTFNH

Alt. to Belden

No. of Pairs

Weight kg/km

O/D mm

Voltage

1048A LSHF

2

115

9.9

600V

Construction - Overall Screened Triple 14AWG 3 x 14(41) AWG, 2.0mm2, plain copper conductor, (colour code: black, white, red) Low Smoke Halogen Free insulation, polyester tape, 90% tinned copper wire braid, black Low Smoke Halogen Free sheath. Part No.

No. of Cores

Weight kg/km

3

128

1403COBYH

O/D mm

Voltage

9.1

600V

Construction - Overall Screened Triple 22 & 18AWG Tinned copper conductor, colour coded PVC insulation, black, red, white. Aluminium/polyester foil screen with drain wire. PVC jacket.

FS

cables

FS

FS

FS

FS

FS

No. of Cores

AWG

CSA mm2

Weight kg/km

O/D mm

Voltage

2203COFY 1803COFY

9363 9365

3 3

22(7) 18(16)

0.35 0.79

39 64

5.3 6.3

300V 300V

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Low Smoke Halogen Free

cables

FS

Alt. to Belden

cables

FS

Part No.

cables


22

DATA IBM, Ethernet & Twin-Ax Cables

IBM Cables, Ethernet Cables & Twin-Ax Cables Although many of these cables are no longer used on new installations we still have stock of some types which can be useful if you are extending an existing system. Please call us to discuss your needs. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke. Part No.

2202PTDP

Reference

The insulation and sheath materials are replaced

Alt. to Belden

IBM Part No.

Description

O/D mm

IBM Cables 2202PTDP

IBM Type 1A

9688

4716748

2 x 2 x 22AWG

7.8 x 12

2202PTDPH

IBM Type 1A

LSHF

4716734

2 x 2 x 22AWG

7.8 x 12

2404PUY

IBM Type 3

-

-

4 x 2 x 22AWG

4.7

2602PODF

IBM Type 6

1215A

4716743

2 x 2 x 26(7)AWG

8.7

2601PODF

IBM Type 7

-

4716746

1 x 2 x 26(7)AWG

6.3

Description

Stranding AWG

Capacitance pF/m C/C

O/D mm

Trunk

12(1)

Part No.

Alt. to Belden

Ethernet 10BASE5 1201AXDD

9880

85

10.3

2004PTMFH

9901 LSHF

Grey AUI Drop 4 x 2 x 20(7)

55

10.7

2203PTMP

9891

Blue AUI Drop 3 x 2 x 22(7)

55

9.9

Stranding AWG

Capacitance pF/m C/C

O/D mm

+ 1 x 2 x 20(7) Part No.

Alt. to Belden

Description

Ethernet 10BASE2 200278DPH

cables

FS

2001AXD

9907

Thinnet

20(19)

86

4.6

2001AXDH

LSHF

Thinnet

20(19)

86

4.6

Twin-Axial cables were originally developed for I/O switching & process control applications. Now widely used in commercial applications such as building management systems. Most types are also stocked in Low Smoke Halogen Free versions as well as PVC. If the Twin-Ax you are looking for is not shown please call us. Part No.

FS cables

cables

FS

FS cables

Alt. to Belden

AWG

O/D mm

Cap. pF/m C/C

Imp. Ohms

Colour

Twin-Ax 220215FF

9182

22(19)

8.9

29

150

Black

220215FFH

LSHF

22(19)

8.9

29

150

Black

200278BP

9272

20(7)

6.2

65

78

Blue

200278BPH

LSHF

20(7)

6.2

65

78

Blue

200278DP

9463

20(7)

6.2

65

78

Blue

200278DPH

LSHF

20(7)

6.2

65

78

Blue

200210DP

9207

20(7)

8.4

51

100

Black

200210DPH

LSHF

20(7)

8.4

51

100

Black

160212DP

9860

16(1)

11.2

36

124

Black

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


23

Transducer & Load Cell Cables DATA Transducer & Load Cell Cables

Developed for accurate signal transmission in physically demanding conditions the FSC range of transducer and load cell cables cover all the popular types. The ultra tough polyurethane jacket provides excellent protection against both water and mechanical damage. To guard against the effects of nearby power cables or other sources of electromagnetic radiation a choice of either a foil screen with drain wire or a high density tinned copper wire braid is offered.

Construction - Foil Screened

Technical Information

Tinned or plain copper conductor, colour coded PE or

Voltage Rating:

300V

PVC insulation, polyester tape, tinned copper drain

Temperature Rating:

-30ยบC to +80ยบC

wire, inward facing aluminium/polyester tape, tough

Max Conductor Resistance:

polyurethane gloss jacket.

0.09mm2 (28AWG):

232 Ohms per km

0.22mm2 (24AWG):

92 Ohms per km

0.34mm2 (22AWG):

57 Ohms per km

Part No.

Cores x mm2

Weight kg/km

O/D mm

Insulation Type

Screen Type

Colour

9950020408

4 x 0.22

29

4.6

PE

Foil

Orange

9950020608

6 x 0.22

36

6.2

PE

Foil

Orange

9950030408

4 x 0.34

35

6.0

PE

Foil

Orange

9950009405

4 x 0.09

21

4.0

PVC

Foil

Grey

Construction - Braid Screened

Technical Information

Tinned or plain copper conductor, colour coded cold

Voltage Rating:

300V

resistant PVC insulation, polyester tape, high

Temperature Rating:

-30ยบC to +80ยบC

coverage tinned copper wire braid, tough

Max Conductor Resistance:

polyurethane gloss jacket.

0.055mm2 (30AWG):

367 Ohms per km

0.5mm2 (20AWG):

39 Ohms per km

9950020408

9960050400 Weight kg/km

O/D mm

Insulation Type

Screen Type

Colour

12 x 0.055

32

4.3

PVC

Braid

Black

9960020400

4 x 0.22

34

4.7

PVC

Braid

Black

9960050400

4 x 0.50

65

6.8

PVC

Braid

Black

39300112PUR

FS

FS

cables

Cores x mm2

cables

Part No.

cables

FS

FS

FS

FS

FS

cables

cables

Other sizes, colours and insulation types can be supplied for quantities as low as 2km. Cable can be printed with your company name or message and phone number. See pages 152-153 for details.

cables

FS

Full specifications sheets are available on the above giving electrical characteristics and colour codes.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


24

DATA Structured Wiring

Cat5E UTP, Cat5E Screened, Cat 6A Screened & Unscreened & Cat 7 Screened The benefits of running voice, data or video over the same cabling system are considerable. The versatility of the latest structured wiring systems ensure confidence that future needs can be easily met with minimal expense or inconvenience to other network users. The majority of installations use unshielded twisted pair (UTP) cables. Baluns allow RGB video signals to be transmitted using UTP, saving the cost of running dedicated wiring for many dealing room systems. Where higher performance cables for ATM, multimedia and similar applications are required, please call us for the latest information. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

Part No.

Description

Colour Weight kg/km

Cat-5E UTP Solid Conductors C51HR† 1 x 2 x 24AWG UTP LSHF C5E2HR* 2 x 2 x 24AWG UTP LSHF C5EB 4 x 2 x 24AWG UTP PVC C5EC 4 x 2 x 24AWG UTP PE C5ECB 4 x 2 x 24AWG UTP PE C5ER 4 x 2 x 24AWG UTP PVC C5EHB 4 x 2 x 24AWG UTP LSHF C5EHR 4 x 2 x 24AWG UTP LSHF C5ER-Shotgun 4 x 2 x 24AWG UTP PVC C5EHR-Shotgun 4 x 2 x 24AWG UTP LSHF Cat-5E UTP Conductors (Patch) Stranded C5EPB00 4 x 2 x 24AWG UTP PVC C5EPB01 4 x 2 x 24AWG UTP PVC C5EPB03 4 x 2 x 24AWG UTP PVC C5EPB04 4 x 2 x 24AWG UTP PVC C5EPB05 4 x 2 x 24AWG UTP PVC C5EPB06 4 x 2 x 24AWG UTP PVC C5EPB07 4 x 2 x 24AWG UTP PVC C5EPB08 4 x 2 x 24AWG UTP PVC C5EPB09 4 x 2 x 24AWG UTP PVC C5EPB10 4 x 2 x 24AWG UTP PVC C5EPHR00 4 x 2 x 24AWG UTP LSHF C5EPHR01 4 x 2 x 24AWG UTP LSHF C5EPHR03 4 x 2 x 24AWG UTP LSHF C5EPHR04 4 x 2 x 24AWG UTP LSHF cables C5EPHR05 4 x 2 x 24AWG UTP LSHF C5EPHR06 4 x 2 x 24AWG UTP LSHF C5EPHR07 4 x 2 x 24AWG UTP LSHF C5EPHR08 4 x 2 x 24AWG UTP LSHF C5EPHR09 4 x 2 x 24AWG UTP LSHF C5EPHR10 4 x 2 x 24AWG UTP LSHF cables

FS

FS

cables

FS

Grey Grey Grey Black Black Grey Violet Grey Grey Orange

12 22 36 36 36 36 36 36 74 74

Black Blue Red White Grey Violet Pink Orange Yellow Green Black Blue Red White Grey Violet Pink Orange Yellow Green

36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36

O/D mm

The insulation and sheath materials are replaced

Pack Lengths

2.8 Reel 4.4 Reel 5.5 305m Box 5.5 Reel 5.5 305m Box 5.5 Reel 5.5 305m Box 5.5 Reel 10.8 x 6.2 Reel 10.8 x 6.2 Reel 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5

305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box 305m Box Reel Reel Reel Reel Reel Reel Reel Reel Reel Reel

RJ45 Part No.

RJ45 Strain Relief Boot

RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP

RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST

RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP RJ45UTPP

RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST RJ45UTPP-ST

† Not to Cat-5E standard * This cable is an alternative to Belden 1588A

FS cables

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


25

Structured Wiring DATA Part No.

Description

Colour

Weight kg/km

O/D mm

Pack Lengths

RJ45 Part No.

RJ45 Strain Relief Boot

Cat 5E FTP Overall Foil Screened Solid Conductors C5EFR

4 x 2 x 24AWG FTP PVC

Grey

40

6.0

Reel

RJ45STPP

RJ45UTPP-ST

C5EFHR

4 x 2 x 24AWG FTP LSHF

Orange

40

6.0

Reel

RJ45STPP

RJ45UTPP-ST

Cat 5E FTP Overall Foil Screened Stranded Conductors (Patch) C5EPFB01

4 x 2 x 24AWG FTP PVC

Blue

40

6.0

305m Box

RJ45STPP

RJ45UTPP-ST

C5EPFB03

4 x 2 x 24AWG FTP PVC

Red

40

6.0

305m Box

RJ45STPP

RJ45UTPP-ST

C5EPFB05

4 x 2 x 24AWG FTP PVC

Grey

40

6.0

305m Box

RJ45STPP

RJ45UTPP-ST

C5EPFB10

4 x 2 x 24AWG FTP PVC

Green

40

6.0

305m Box

RJ45STPP

RJ45UTPP-ST

Cat 6 UTP Solid Conductors C6B

4 x 2 x 24AWG UTP PVC

Grey

43

6.3

305m Box

-

-

C6R

4 x 2 x 24AWG UTP PVC

Grey

43

6.3

Reel

-

-

C6HB

4 x 2 x 24AWG UTP LSHF

Violet

43

6.3

305m Box

-

-

C6HR

4 x 2 x 24AWG UTP LSHF

Grey

43

6.3

Reel

-

-

Cat 6 FTP Solid Conductors C6FR

4 x 2 x 23AWG FTP PVC

Grey

58

7.2

Reel

-

-

C6FHR

4 x 2 x 23AWG FTP LSHF

Orange

58

7.2

Reel

-

-

8.0

Reel

-

-

Reel

-

-

Reel

-

-

Cat 6A F-FTP Individual & Overall Foil Screened Solid Conductors C6GFFH

4 x 2 x 23AWG F-FTP LSHF

Blue

58

Cat 7 S/FTP Individual Foil & Overall Braid Screened Solid Conductors C7HR08

4 x 2 x 23AWG S/FTP LSHF

C7HR08-Shotgun 2 x (2 x 4) x 23AWG S/FTP LSHF

Orange

60

Orange

121 7.7 x 15.7

7.4

C6HB

FS

cables

FS

FS

FS

FS

FS

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Low Smoke Halogen Free

cables

FS

cables

FS

cables


26

DATA External Grade Structured Wiring

External Grade Structured Wiring Category or structured wiring cable has always been on the delicate side, but treated carefully it does the job well. Now there is a cable available to cover the more demanding jobs. Designed for fixed installations, the FSC range of duct grade or armoured Cat-5 & Cat-6 cables have heavy jackets of polyethylene to protect against moisture and give the cables extra strength. The external version is ideal for running through ducts, up the side of a building or up masts. The armoured version is great for direct burial or vandal-plagued installations. These cables are supplied on drums.

Part No.

Description

Weight kg/km

O/D mm

Cat-5E UTP C5EA

C5EC

4 x 2 x 24AWG Cat-5E UTP PE - Weatherproof

40

5.6

C5ED

4 x 2 x 24AWG Cat-5E UTP PVC/PE - Duct Grade

67

8.6

C5EA

4 x 2 x 24AWG Cat-5E UTP PVC/PE/SWA/PE - Armoured

239

12.6

C525D

25 x 2 x 24AWG Cat-5 UTP PVC/PE - Duct Grade

278

17.0

C525A

25 x 2 x 24AWG Cat-5 UTP PVC/PE/SWA/PE - Armoured

598

21.6

Part No.

Description

Weight kg/km

O/D mm

Cat-5E FTP C5EFD

4 x 2 x 24AWG Cat-5E FTP PVC/PE - Duct Grade

68

8.8

C5EFA

4 x 2 x 24AWG Cat-5E FTP PVC/PE/SWA/PE - Armoured

275

12.2

Part No.

Description

Weight kg/km

O/D mm

Cat-6 UTP cables

FS

C6D

C6D

4 x 2 x 23AWG Cat-6 UTP PVC/PE - Duct Grade

86

9.9

C6A

4 x 2 x 23AWG Cat-6 UTP PVC/PE/SWA/PE - Armoured

309

14.2

Weight kg/km

O/D mm

Part No.

FS cables

cables

FS

FS cables

Description

Cat-6 FTP C6FD

4 x 2 x 23AWG Cat-6 FTP PVC/PE - Duct Grade

105

10.2

C6FA

4 x 2 x 23AWG Cat-6 FTP PVC/PE/SWA/PE - Armoured

315

14.5

Please note the armouring and oversheathing process can sometimes affect the performance of the cable. If your installation is likely to require optimum performance please check before installing to ensure it meets your requirement. Duct Grade

SWA

www.fscables.com

sales@fscables.com


27

Cat 3 & Cat 5 Multipair ADSL DATA Cat 3 Multipair & Cat 5 Multipair

With the spread of internet access over broadband, the need for high specification cables has grown. Cable to support ADSL data rates are increasingly being installed in offices, airports, education and commercial centres. Cat-3 multipair is available in 25, 50, 100, 150 & 200 pair configurations and offers substantial benefits in terms of cost, space & weight with significantly reduced installation times when compared with multiple runs of standard 4 pair Cat-5 cable. Multipair Cat-5 offers the same advantages as Cat-3 but at higher data rates. Low Smoke Halogen Free versions are available where indicated with by those that do not emit halogens or toxic smoke.

The insulation and sheath materials are replaced

Construction - Cat-3 Multipair

Technical Information

24(1) AWG solid plain copper conductor, colour coded HDPE insulation, twisted into pairs and laid up, polyester tape, PVC sheath.

Minimum Bend Radius: Conductor DCR: Colour Code:

Part No.

Cable Size

Jacket

Weight kg/km

10 x cable O/D ≤ 9,38 Ohm/100m Chart 5 page 166 O/D mm

C310

10 x 2 x 24AWG

PVC

67

7.3

C310H

10 x 2 x 24AWG

LSHF

67

7.3

C325

25 x 2 x 24AWG

PVC

186

11.5

C325H

25 x 2 x 24AWG

LSHF

186

11.5

C350

50 x 2 x 24AWG

PVC

422

17.5

C350H

50 x 2 x 24AWG

LSHF

422

17.5

PVC

710

23.5

100 x 2 x 24AWG

LSHF

710

23.5

C3150

150 x 2 x 24AWG

PVC

880

28.0

C3150H

150 x 2 x 24AWG

LSHF

880

28.0

C3200

200 x 2 x 24AWG

PVC

1047

33.0

C3200H

200 x 2 x 24AWG

LSHF

1047

33.0

Technical Information

24(1) AWG solid plain copper conductor, colour coded PE insulation twisted into pairs. Laid up into a bundle and jacketed in PVC.

Minimum Bend Radius: Conductor DCR: Colour Code:

Part No.

Cable Size

Jacket

Weight kg/km

25 x 2 x 24AWG

PVC

189

13.2

25 x 2 x 24AWG

LSHF

189

13.2

FS

FS

FS

FS

FS

cables

PVC

435

20.8

LSHF

435

20.8

cables

cables

50 x 2 x 24AWG 50 x 2 x 24AWG

cables

C550 C550H

Fax : 01727 840 842

cables

O/D mm

C525

Tel: 01727 840 841

FS

C525H

FS

10 x cable O/D ≤ 9,38 Ohm/100m Chart 5 page 166

C525H

Low Smoke Halogen Free

FS

cables

100 x 2 x 24AWG

C3100H

cables

C3100

Construction - Cat-5 Multipair

C350H

cables


28

COAXIAL RG Coaxial

RG Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV The RG cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be supplied on request as can armoured versions or alternative sheath colours. Twin and multicore versions are available in some types.

Part No.

Description

Imp. Central Ohms Cond.

Shield

Dielectric Outer Weight Sheath kg/km

O/D mm

75 Ohm

390059

cables

FS

FS cables

390006-C

RG6 Type

75

1/1.02

Ali Foil & Braid

FPE

PVC

47

6.8

390006-CH

RG6 Type LSHF

75

1/1.02

Ali Foil & Braid

FPE

LSHF

47

6.8

390006Q

RG6 Quad

75

1/1.02

2 x Ali Foil & Braid

FPE

PVC

49

7.6

390011

RG11 A/U

75

7/0.40

PCWB

PE

PVC

149

10.3

390011H

RG11 A/U LSHF

75

7/0.40

PCWB

PE

LSHF

149

10.3

390011A

RG11 A/U SWA

75

7/0.40

PCWB

PE

LDPE

380

15.7

390059

RG59 B/U

75

1/0.58

PCWB

PE

PVC

60

6.1

390059L

RG59 B/U LSF

75

1/0.58

PCWB

PE

LSF

60

6.1

390059H

RG59 B/U LSHF

75

1/0.58

PCWB

PE

LSHF

60

6.1

390059D

RG59 B/U Duct

75

1/0.58

PCWB

PE

LDPE

60

7.9

390059A

RG59 B/U SWA

75

1/0.58

PCWB

PE

LDPE

60

10.3

390059MB

RG59 Mini Black

75

1/0.41

TCWB

PE

PVC

16

3.6

390059MW

RG59 Mini White

75

1/0.41

TCWB

PE

PVC

16

3.6

390059MBH

RG59 Mini Black LSHF

75

1/0.41

TCWB

PE

LSHF

16

3.6

390059MWH

RG59 Mini White LSHF

75

1/0.41

TCWB

PE

LSHF

16

3.6

390179

RG179 B/U

75

7/0.10

SPCWB

PTFE

FEP

15

2.5

390179Y

RG179 PVC

75

1/0.35

TCWB

PE

PVC

12

2.6

390179H

RG179 LSHF

75

1/0.35

TCWB

PE

LSHF

12

2.6

390179Y-S

RG179 Stranded PVC

75

7/0.10

TCWB

PE

PVC

12

2.6

390179H-S

RG179 Stranded LSHF

75

7/0.10

TCWB

PE

LSHF

12

2.6

390216

RG216

75

7/0.40

2 x PCWB

PE

PVC

169

10.8

390216H

RG216 LSHF

75

7/0.40

2 x PCWB

PE

LSHF

169

10.8

390302

RG302

75

1/0.63

SPCWB

PTFE

FEP

4.7

5.3

Part No.

Description

Imp. Central Ohms Cond.

Shield

Dielectric Outer Weight Sheath kg/km

78, 93 & 95 Ohm 390062

RG62 A/U

93

1/0.69

PCWB

PESS

PVC

60

390062H

RG62 A/U LSHF

93

1/0.69

PCWB

PESS

PVC

60

6.2

390062A

RG62 A/U SWA

93

1/0.69

PCWB

PESS

PVC

210

10.4

390108

RG108 Twin-Ax

78 2 x 7/0.32

TCWB

PE

PVC

48

5.9

390180

RG180

95

SPCWB

PTFE

FEP

29

3.7

1/0.30

cables

FS

FS cables

O/D mm

Low Smoke Halogen Free

Duct Grade

SWA

www.fscables.com

sales@fscables.com

6.2


29

RG Coaxial COAXIAL Sheath, Insulation and Shield Codes FEP FPE LDPE PTFE PESS TCWB

Fluorinated Ethylene Propylene Foamed Polyethylene Low Density Polyethylene PolyTetraFluoroEthylene Polyethylene Semi Solid Tinned Copper Wire Braid

Description

TFE PEAS PVC PEC GFB SPCWB BNC

Crimp Plug

Crimp Jack

TetraFluoroEthylene Polyethylene Air Spaced Polyvinyl Chloride Polyethylene Cellular Glass Fibre Braid Silver Plated Copper Wire Braid

F-Type

Twist-on Plug

Boots

Crimp Plug

N-Type

Crimp Jack

Crimp Plug

TNC

Crimp Jack

Crimp Plug

Crimp Tool

Crimp Jack

Connectors RG6 Type

YB1BC1

YB1BC2

-

-

YB1FC1 YB1BC2

-

-

-

-

YTC2

RG6 Type LSHF

YB1BC1

YB1BC2

-

-

YB1FC1 YB1BC2

-

-

-

-

YTC2

YB1BC1

YB1BC2

-

-

YB1FC1 YB1BC2

-

-

-

-

YTC2

RG11 A/U

YA2BC1

YA2BC2

-

-

YA2FC1 YA2FC2

YA2NC1

YA2NC2

-

-

YTC3

RG11 A/U LSHF

YA2BC1

YA2BC2

-

-

YA2FC1 YA2FC2

YA2NC1

YA2NC2

-

-

YTC3

RG11 A/U SWA

YA2BC1

YA2BC2

-

-

YA2FC1 YA2FC2

YA2NC1

YA2NC2

-

-

YTC3

RG59 B/U PVC

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx

YA1FC1 YA1FC2

YA1NC1

YA1NC2 YA1TC1 YA1TC2

YTC1

RG59 B/U LSF

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx

YA1FC1 YA1FC2

YA1NC1

YA1NC2 YA1TC1 YA1TC2

YTC1

RG59 B/U LSHF

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx

YA1FC1 YA1FC2

YA1NC1

YA1NC2 YA1TC1 YA1TC2

YTC1

RG59 B/U Duct

YA1BC1

YA1BC2

YA1BT1

-

YA1FC1 YA1FC2

YA1NC1

YA1NC2 YA1TC1 YA1TC2

YTC1

RG59 B/U SWA

YA1BC1

YA1BC2

YA1BT1

-

YA1FC1 YA1FC2

YA1NC1

YA1NC2 YA1TC1 YA1TC2

YTC1

RG59 Mini Black

YA8BC1

YA8BC2

-

YA8BX700

-

-

-

-

-

-

YTC1

RG59 Mini White

YA8BC1

YA8BC2

-

YA8BX704

-

-

-

-

-

-

YTC1

RG59 Mini Black LSHF

YA8BC1

YA8BC2

-

YA8BX700

-

-

-

-

-

-

YTC1

RG59 Mini White LSHF

YA8BC1

YA8BC2

-

YA8BX704

-

-

-

-

-

-

YTC1

RG179 B/U

YA7BC1

YA7BC2

-

YA7BX7xx

YA7FC1

-

-

-

-

-

YTC1

RG179 PVC

YA7BC1

YA7BC2

-

YA7BX7xx

YA7FC1

-

-

-

-

-

YTC1

RG179 LSHF

YA7BC1

YA7BC2

-

YA7BX7xx

YA7FC1

-

-

-

-

-

YTC1

RG179 Stranded PVC

YA7BC1

YA7BC2

-

YA7BX7xx

YA7FC1

-

-

-

-

-

YTC1

RG179 Stranded LSHF

YA7BC1

YA7BC2

-

YA7BX7xx

YA7FC1

-

-

-

-

-

YTC1

RG216

-

-

-

-

-

-

-

-

RG216 LSHF

-

-

-

-

-

-

-

RG302

-

-

-

-

-

-

-

Crimp Plug

Crimp Jack

Twist-on Plug

Boots

Crimp Plug

Crimp Jack

Crimp Plug

RG62 A/U

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx

YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1 cables

YA1TC2

RG62 A/U LSHF

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx

YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

RG62 A/U SWA

YA1BC1

YA1BC2

YA1BT1

-

YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

RG108 Twin-Ax

-

-

-

-

-

-

-

-

-

-

-

RG180

-

-

-

-

-

-

-

-

-

-

-

BNC

F-Type

White

Tel: 01727 840 841

-

-

Fax : 01727 840 842

FS -

-

TNC

Crimp Jack

Crimp Plug

FS

Crimp Jack

Crimp Tool

FS YTC1 cables

FS

FS

FS

FS

cables

cables

04

-

FS

cables

To show the colour required please replace xx in the part number with: Black

-

N-Type

Connectors

00

-

cables

Description

-

-

cables

RG6 Quad

cables


30

COAXIAL RG Coaxial

RG Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV The RG cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be supplied on request as can armoured versions or alternative sheath colours. Twin and multicore versions are available in some types.

Part No.

Description

Imp. Central Ohms Cond.

Shield

Dielectric Outer Weight Sheath kg/km

O/D mm

50 Ohm RG Coaxial Cables

390059

cables

FS

FS cables

390008-C

RG 8 Type

50

1/2.74

Ali Foil & TCWB

PE

PE

207

10.2

390008-CH

RG 8 Type LSHF

50

1/2.74

Ali Foil & TCWB

PE

LSHF

207

10.2

390058

RG 58 C/U

50

19/0.18

TCWB

PE

PVC

46

5.1

390058H

RG 58 C/U LSHF

50

19/0.18

TCWB

PE

LSHF

46

5.1

390058D

RG 58 C/U Duct

50

19/0.18

TCWB

PE

LDPE

46

6.5

390058W

RG 58 C/U White

50

19/0.18

TCWB

PE

PVC

46

5.1

390115

RG115 A/U

50

7/0.71

2 x SPCWB

PTFE

GFB

240

10.6

390142

RG142 B/U

50

1/0.91

2 x SPCWB

PTFE

FEP

74

4.9

390165

RG165

50

7/0.81

SPCWB

PTFE

GFB

180

10.4

390174

RG174 A/U

50

7/0.16

TCWB

PE

PVC

16

2.6

390174H

RG174 A/U LSHF

50

7/0.16

TCWB

PE

LSHF

16

2.6

390178

RG178 B/U

50

7/0.10

SPCWB

PTFE

FEP

10

1.8

390179DB

RG178 B/U Double braid

50

7/0.10

2 x SPCWB

PTFE

FEP

14

2.3

390188

RG188

50

7/0.17

SPCWB

PTFE

FEP

17

2.5

390196

RG196

50

7/0.10

SPCWB

PTFE

FEP

9

2.0

390212

RG212

50

1/1.41

2 x SPCWB

PE

PVC

123

8.4

390213

RG213 /U

50

7/0.75

PCWB

PE

PVC

166

10.3

390213H

RG213 /U LSHF

50

7/0.75

PCWB

PE

LSHF

166

10.3

390214

RG214 /U

50

7/0.75

2 x SPCWB

PE

PVC

173

10.8

390214H

RG214 /U LSHF

50

7/0.75

2 x SPCWB

PE

PVC

173

10.8

390218

RG218

50

1/4.95

PCWB

PE

PVC

658

22.0

390223

RG223 /U

50

1/0.90

2 x SPCWB

PE

PVC

49

5.4

390223H

RG223 /U LSHF

50

1/0.90

2 x SPCWB

PE

LSHF

49

5.4

390225

RG225

50

7/0.79

2 x SPCWB

PTFE

GFB

268

10.9

390303

RG303

50

1/0.99

SPCWB

PTFE

FEP

47

5.3

390304

RG304

50

1/1.49

2 x SPCWB

PTFE

FEP

131

7.1

390316

RG316

50

7/0.17

SPCWB

PTFE

FEP

15

2.5

390316DB

RG316 Double Braid

50

7/0.17

2 x SPCWB

PTFE

FEP

22

2.6

390393

RG393

50

7/0.80

2 x SPCWB

PTFE

FEP

245

10.0

390400

RG400

50

19/0.20

2 x SPCWB

PTFE

FEP

55

5.1

cables

FS

FS cables

Low Smoke Halogen Free

Duct Grade

www.fscables.com

sales@fscables.com


31

RG Coaxial COAXIAL Sheath, Insulation and Shield Codes FEP FPE LDPE PTFE PESS TCWB

Fluorinated Ethylene Propylene Foamed Polyethylene Low Density Polyethylene PolyTetraFluoroEthylene Polyethylene Semi Solid Tinned Copper Wire Braid

Description

TFE PEAS PVC PEC GFB SPCWB BNC

Crimp Plug

Crimp Jack

TetraFluoroEthylene Polyethylene Air Spaced Polyvinyl Chloride Polyethylene Cellular Glass Fibre Braid Silver Plated Copper Wire Braid

F-Type

Twist-on Plug

Boots

Crimp Plug

N-Type

Crimp Jack

Crimp Plug

TNC

Crimp Jack

Crimp Plug

Crimp Tool

Crimp Jack

Connectors RG 8 Type

YA9BC1

YA9BC2

-

-

-

-

YA9NC1 YA9NC2

-

-

390L40-T1

RG 8 Type LSHF

YA9BC1

YA9BC2

-

-

-

-

YA9NC1 YA9NC2

-

-

390L40-T1 YTC1

RG 58 C/U

YA3BC1

YA3BC2

YA3BT1

YA3BX700

-

-

YA3NC1 YA3NC1 YA3TC1

YA3TC2

RG 58 C/U LSHF

YA3BC1

YA3BC2

YA3BT1

YA3BX700

-

-

YA3NC1 YA3NC1 YA3TC1

YA3TC2

YTC1

RG 58 C/U Duct

YA3BC1

YA3BC2

YA3BT1

-

-

-

YA3NC1 YA3NC1 YA3TC1

YA3TC2

YTC1

RG 58 C/U White

YA3NC1 YA3NC1 YA3TC1

YA3BC1

YA3BC2

YA3BT1

YA3BX700

-

-

YA3TC2

YTC1

RG115 A/U

-

-

-

-

-

-

-

-

-

-

-

RG142 B/U

-

-

-

-

-

-

-

-

-

-

-

RG165

-

-

-

-

-

-

-

-

-

-

-

RG174 A/U

YA7BC1

YA7BC2

-

YA7BX7xx YA7FC1

-

-

-

-

-

YTC1

RG174 A/U LSHF

YA7BC1

YA7BC2

-

YA7BX7xx YA7FC1

-

-

-

-

-

YTC1

RG178 B/U

YC6BC1

-

-

-

-

-

-

-

-

-

-

RG178 B/U Double Braid

YC6BC1

-

-

-

-

-

-

-

-

-

-

RG188

-

-

-

-

-

-

-

-

-

-

-

RG196

-

-

-

-

-

-

-

-

-

-

-

RG212

-

-

-

-

-

-

-

-

-

-

-

RG213 /U

YA4BC1

YA4BC2

-

-

-

-

YA4NC1 YA4NC2 YA4TC1

YA4TC2

YTC3

RG213 /U LSHF

YA4BC1

YA4BC2

-

-

-

-

YA4NC1 YA4NC2 YA4TC1

YA4TC2

YTC3

RG214 /U

YA5BC1

YA5BC2

-

-

-

-

YA5NC1 YA5NC2

-

-

YTC7

RG214 /U LSHF

YA5BC1

YA5BC2

-

-

-

-

YA5NC1 YA5NC2

-

-

YTC7

RG218

-

-

-

-

-

-

RG223 /U

YA6BC1

YA6BC2

-

-

-

-

YA6NC1 YA6NC2 YA6TC1

-

-

-

YA6TC2

YTC1

RG223 /U LSHF

YA6NC1 YA6NC2 YA6TC1

YA6BC2

-

-

-

-

-

-

-

-

-

-

-

RG303

-

-

-

-

-

-

RG304

-

-

-

-

-

RG316

YC4BC1

YC4BC2

-

-

-

RG316 Double Braid

-

FS

YA6TC2

YTC1

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

YC4BC1

YC4BC2

-

-

-

-

-

RG393

-

-

-

-

-

-

-

RG400

YA6BC1

YA6BC2

-

-

-

-

FS

-

FS

-

YC4TC1

YC4TC2

YTC1

-

YC4TC1

YC4TC2

YTC1

cables

YA6NC1 YA6NC2 YA6TC1

-

cables

FS

cables

YA6BC1

RG225

-

-

cables

YA6TC2

YTC1

To show the colour required please replace xx in the part number with: 04

White

Tel: 01727 840 841

FS

FS

Fax : 01727 840 842

FS

FS

cables

cables

Black

cables

00

cables


32

COAXIAL Broadcast Coaxial

Broadcast Coaxial XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV

There is an increasing demand for Broadcast standard video cables. The best known are the BBC specification PSF series for which we stock a range of alternatives.

Part No.

390PS13

Description

Broadcast Coax 390PS12 PSF1/2 Style 390PS12H PSF1/2 Style LSHF 390PS13 PSF1/3 Style 390PS1301 PSF1/3 Style 390PS1302 PSF1/3 Style 390PS1303 PSF1/3 Style 390PS1306 PSF1/3 Style 390PS1310 PSF1/3 Style 390PS13H PSF1/3 Style LSHF 390PS13H01 PSF1/3 Style LSHF 390PS16 PSF1/6 Style 390PS17 PSF1/7 Style 390PS19 PSF1/9 Style Triax

Imp. Ohms

Central Cond.

75 75 75 75 75 75 75 75 75 75 75 75 75

1/0.80 1/0.80 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 1/0.60 7/0.32 1/0.42 1/1.40

Description

Shield

2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x PCWB TCWB 1 x TCWB + 1 x PCWB

Dielectric Outer Sheath

PE PE PE PE PE PE PE PE PE PE PE PPC PEC

PVC LSHF PVC PVC PVC PVC PVC PVC LSHF LSHF PVC PVC PUR

BNC

Colour

Weight kg/km

O/D mm

Cream Cream Cream Blue Brown Red Violet Green Cream Blue Black Cream Red

93 93 74 74 74 74 74 74 74 74 44 14 160

7.5 7.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 5.2 2.9 11.2

Crimp Tool

Crimp Plug

Crimp Jack

YB5BC1 YB5BC1 YC9BC1 -

-

Connectors PSF1/2 Style PSF1/2 Style LSHF PSF1/3 Style PSF1/3 Style LSHF PSF1/6 Style PSF1/7 Style PSF1/9 Style Triax

YTC1 YTC1 -

390CC11 cables

FS

Part No.

FS cables

cables

FS

FS cables

Description

Imp. Central Ohms Cond.

Camera Cable Triax 390CC08 Camera Cable 8 390CC08H Camera Cable 8 LSHF 390CC08P Camera Cable 8 PUR 390CF08 Camera Cable 8 Flexible 390CC11 Camera Cable 11 390CC11H Camera Cable 11 LSHF 390CC11P Camera Cable 11 PUR 390CF11 Camera Cable 11 Flexible 390CC14 Camera Cable 14 390CC14H Camera Cable 14 LSHF 390CC14P Camera Cable 14 PUR

Shield

75 1/1.0 1 x TCWB + 1 x PCWB 75 1/1.0 1 x TCWB + 1 x PCWB 75 1/1.0 1 x TCWB + 1 x PCWB 75 7/0.35 1 x TCWB + 1 x PCWB 75 1/1.40 1 x TCWB + 1 x PCWB 75 1/1.40 1 x TCWB + 1 x PCWB 75 1/1.40 1 x TCWB + 1 x PCWB 75 19/0.30 1 x TCWB + 1 x PCWB 75 7/0.75 1 x TCWB + 1 x PCWB 75 7/0.75 1 x TCWB + 1 x PCWB 75 7/0.75 1 x TCWB + 1 x PCWB

Dielectric Outer Colour Sheath

FPE FPE FPE FPE FPE FPE FPE FPE FPE FPE FPE

PVC LSHF PUR TPE PVC LSHF PUR TPE PVC LSHF PUR

Red Red Red Red Red Red Red Red Red Red Red

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com

Weight kg/km

O/D mm

106 106 106 102 160 160 160 158 268 268 268

8.5 8.5 8.5 8.5 11.2 11.2 11.2 11.2 14.0 14.0 14.0


33

Broadcast Coaxial COAXIAL Telecom BT, TZC & RA Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Res LSHF Power Cable – 0.6/1kV The BT range of coaxial cables are to British Telecom specifications and are

used for interconnecting equipment. British Telecom types BT2002 & BT2003 are used for digital telephone and data links. BT2002 is equivalent to ICL Part Number 80047293. TZC coax is to a very similar standard to the BT3002 and is available in both single and multicore options from stock. The cable is designed for Ericsson systems. RA7000 has been developed as a higher performance version of BT2003 but with a smaller overall diameter. RA8000 is a high performance alternative to BT3002 with a much smaller overall diameter. Multicore versions are also available. Part No.

Description

Imp. Ohms

Central Cond.

Shield

Dielectric

Outer Sheath

Weight kg/km

O/D mm

75 75 75 75 75 75 75 75 75

7/0.20 7/0.20 7/0.20 1/0.61 1/0.61 1/0.31 1/0.31 1/0.31 1/0.31

PCWB 2 x PCWB 2 x PCWB 2 x PCWB 2 x PCWB 2 x TCWB 2 x TCWB 2 x TCWB 2 x TCWB

PEC FPE FPE PE PE PE PE PE PE

PVC PVC LSHF PVC LSHF PVC LSHF PVC PVC

31 51 51 79 79 24 24 214 392

4.6 5.1 5.1 6.7 6.7 3.5 3.5 16.0 19.5

75 75 75

1/0.31 1/0.31 1/0.31

2 x TCWB 2 x TCWB 2 x TCWB

PE PE PE

PVC PVC PVC

24 219 394

3.5 14.5 19.1

75 75 75 75 75 75

1/0.60 1/0.60 1/0.60 1/0.31 1/0.31 1/0.31

Ali Foil & PCWB Ali Foil & PCWB Ali Foil & PCWB Ali Foil & TCWB Ali Foil & TCWB Ali Foil & TCWB

FPE FPE FPE FPE FPE FPE

LSHF LSHF LSHF LSHF LSHF LSHF

30 165 535 13 124 228

4.5 17.2 24.3 2.8 11.0 14.8

Telecom BT Coaxial 3902001 BT2001 3902002 BT2002 3902002H BT2002 LSHF 3902003 BT2003 3902003H BT2003 LSHF 3903002 BT3002 3903002H BT3002 LSHF 3903002/8 BT3002 8core 3903002/16 BT3002 16core TZC Coaxial TZC75024 TZC TZC7502408 TZC 8core TZC7502416 TZC 16core RA Coaxial 390RA7000 RA7000 390RA7000/8 RA7000 8core 390RA7000/16 RA7000 16core 390RA8000 RA8000 390RA8000/8 RA8000 8core 390RA8000/16 RA8000 16core Description

BNC Crimp Plug

Crimp Jack

YB8BC2 YB8BC2 YB7BC2 YB7BC2 YB6BC2 YB6BC2 YB6BC2 YB6BC2

YB84C1 YB84C1 YB74C1 YB74C1 YB64C1 YB64C1 YB64C1 YB64C1

YB84C2 YB84C2 YB74C2 YB74C2 YB64C2 YB64C2 YB64C2 YB64C2

-

YB6BC2 YB6BC2 YB6BC2

YB64C1 YB64C1 YB64C1

YB64C2 YB64C2 YB64C2

-

YB9BC1 YB9BC1 YB9BC1 -

YB9BC2 YB9BC2 YB9BC2 -

YB94C1 YB94C1 YB94C1 -

YB94C2 YB94C2 YB94C2 -

-

Low Smoke Halogen Free

Tel: 01727 840 841

Fax : 01727 840 842

FS

FS

cables

FS

FS

FS

FS

FS

cables

cables

cables

YB6BC1 YB6BC1 YB6BC1

FS

cables

Crimp Plug

cables

TZC Coaxial Connectors TZC TZC 8core TZC 16core RA Coaxial Connectors RA7000 RA7000 8core RA7000 16core RA8000 RA8000 8core RA8000 16core

Crimp Tool

Crimp Jack

cables

Telecom BT Coaxial Connectors BT2001 BT2002 YB8BC1 BT2002 LSHF YB8BC1 BT2003 YB7BC1 BT2003 LSHF YB7BC1 BT3002 YB6BC1 BT3002 LSHF YB6BC1 BT3002 8core YB6BC1 BT3002 16core YB6BC1

T43

3902003

cables


34

COAXIAL URM Coaxial

URM Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV The URM (Uni Radio-Metric) BS 2316 cables listed cover the majority of high frequency data and signal transmission requirements. Other types can be supplied on request, as can armoured, duct grade or alternative sheath colours. URM 70 is widely used for security applications connecting CCTV equipment where the stranded conductor centre is less likely to break than the RG 59 type. This may be important where the camera pans and tilts. Other URM cables are available to order. Part No.

Description

Imp. Ohms

Central Cond.

Shield

Dielectric

Outer Sheath

391043

URM 43

50

391054

URM 54

50

391057

URM 57

391065

URM 65

391067

Weight kg/km

O/D mm

1/0.81

PCWB

PE

PVC

40

5.0

7/0.19

2 x PCWB

PE

PVC

118

8.3

75

1/1.15

PCWB

PE

PVC

158

10.3

75

1/1.15

PCWB

PE

PVC

158

10.3

URM 67

50

7/0.77

PCWB

PE

PVC

162

10.3

URM 67 LSHF

50

7/0.77

PCWB

PE

LSHF

162

10.3

URM 70

75

7/0.19

PCWB

PE

PVC

59

5.8

URM 70 White

75

7/0.19

PCWB

PE

PVC

59

5.8

URM Coaxial Cable

391067

391067H 391070 391070W

391070H cables

FS

391070L

URM 70 LSF

75

7/0.19

PCWB

PE

LSF

59

5.8

391070H

URM 70 LSHF

75

7/0.19

PCWB

PE

LSHF

59

5.8

391070D

URM 70 Duct

75

7/0.19

PCWB

PE

LDPE

72

8.0

391074

URM 74

50

1/4.78

PCWB

PE

PVC

710

22.0

391076

URM 76

50

7/0.32

PCWB

PE

PVC

41

5.1

391091

URM 91

50

7/0.76

2 x PCWB

PE

PVC

170

11.0

391095

URM 95

50

1/0.46

PCWB

PE

Nylon

13

2.3

391106

URM 106

75

1/0.65

SPCWB

PTFE

FEP

45

5.3

391109

URM 109

50

7/0.18

SPCWB

PTFE

FEP

14

2.4

391110

URM 110

50

7/0.11

SPCWB

PTFE

FEP

12

1.8

391111

URM 111

75

7/0.10

SPCWB

PTFE

FEP

14

2.4

391112

URM 112

50

7/0.76

2 x SPCWB

PE

PVC

176

11.0

391115

URM 115

50

1/0.90

2 x PCWB

PE

PVC

85

7.2

391202

URM 202

75

7/0.25

PCWB

PEC

PVC

85

5.1

FS cables

cables

FS

FS cables

Low Smoke Halogen Free

Duct Grade

www.fscables.com

sales@fscables.com


35

URM Coaxial COAXIAL Sheath, Insulation and Shield Codes FEP FPE LDPE PTFE PESS TCWB

Fluorinated Ethylene Propylene Foamed Polyethylene Low Density Polyethylene PolyTetraFluoroEthylene Polyethylene Semi Solid Tinned Copper Wire Braid

Description

TFE PEAS PVC PEC GFB SPCWB

BNC Crimp Plug

Crimp Jack

TetraFluoroEthylene Polyethylene Air Spaced Polyvinyl Chloride Polyethylene Cellular Glass Fibre Braid Silver Plated Copper Wire Braid

F-Type

Twist-on Plug

Boots

Crimp Plug

N-Type

Crimp Jack

Crimp Plug

TNC

Crimp Jack

Crimp Plug

Crimp Tool

Crimp Jack

Connectors URM 43

YA3BC1

YA3BC2

YA3BT1

YA3BX700

-

-

YA3TC2

YTC1

URM 54

-

-

-

-

-

-

-

-

-

-

-

URM 57

-

-

-

-

-

-

-

-

-

-

-

URM 65

-

-

-

-

-

-

-

-

-

-

-

URM 67

YA4BC1

YA4BC2

-

-

-

-

YA4NC1 YA4NC2 YA4TC1

YA4TC2

YTC3

URM 67 LSHF

YA4BC1

YA4BC2

-

-

-

-

YA4NC1 YA4NC2 YA4TC1

YA4TC2

YTC3

URM 70

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

URM 70 White

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

URM 70 LSF

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

URM 70 LSHF

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

URM 70 Duct

YA1BC1

YA1BC2

YA1BT1

-

YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

URM 74

-

-

-

-

-

-

-

-

-

-

-

URM 76

-

-

-

-

-

-

-

-

-

-

-

URM 91

-

-

-

-

-

-

-

-

-

-

-

URM 95

-

-

-

-

-

-

-

-

-

-

-

URM 106

-

-

-

-

-

-

-

-

-

-

-

URM 109

YC4BC1

YC4BC2

-

-

-

-

-

-

YC4TC1

YC4TC2

YTC1

URM 110

-

-

-

-

-

-

-

-

-

-

-

URM 111

-

-

-

-

-

-

-

-

-

URM 112

-

-

-

-

-

-

-

URM 115

-

-

-

-

-

-

-

URM 202

-

-

-

-

-

-

-

Black

04

White

-

-

-

-

-

-

-

-

-

-

cables

FS

FS

FS

FS

FS

cables

cables

cables

Fax : 01727 840 842

-

FS

cables

Tel: 01727 840 841

FS -

cables

00

FS -

cables

To show the colour required please replace xx in the part number with:

YA3NC1 YA3NC1 YA3TC1

cables


36

COAXIAL Digital Satellite & Cable TV Coaxial

Digital Satellite & Cable TV Coaxial The TV range of cable television and video cables is used primarily to carry TV, Satellite and CCTV signals. These cables are all 75 ohm and supplied in a variety of versions to suit different applications. An optional heavy duty tough sheath to improve impact and moisture resistance makes the TV-DB range ideal for pulling into ducts or for direct burial. A version with an aluminium moisture barrier is also available. Cables can be armoured and sheathed with LDPE for quantities as low as 100 metres.

Part No.

392100F Shotgun

cables

FS

FS cables

cables

FS

FS cables

Description

Satellite & Cable TV Coaxial 392100 TV 100 392100W TV 100 White 392100HR TV 100 LSHF 392100F TV 100 392100F/5 TV 100 5core 392100WF TV 100 White 392100H TV 100 LSHF 392100D TV 100 Duct 392100FTV 100 Shotgun Shotgun 392125 TV 125 392125HR TV 125 LSHF 392125DB TV 125 RBS Sheath 392125F TV 125 392125F/5 TV 125 5core 392125HR TV 125 LSHF 392125WH TV 125 White LSHF 392125DBF TV 125 Duct 392167 TV 167 392167DB TV 167 Duct 392167F TV 167 392167H TV 167 LSHF 392233 TV 223 392233DB TV 223 Duct 392233F TV 233 392233H TV 223 LSHF Description

Connectors 392100 392100W 392100HR 392100F 392100F/5 392100WF 392100H 392100D 392100FShotgun 392125 392125HR 392125DB 392125F 392125F/5 392125HR 392125WH 392125DBF

Imp. Ohms

Central Cond.

Shield

Dielectric

Outer Sheath

Weight kg/km

O/D mm

75 75 75 75 75 75 75 75

1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00

Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB

Airspaced PE Airspaced PE Airspaced PE Foamed PE Foamed PE Foamed PE Foamed PE Foamed PE

PVC PVC LSHF PVC PVC PVC LSHF LDPE

49 49 49 49 630 49 49 70

6.6 6.6 6.6 6.6 22.5 6.6 6.6 6.6

75

1.00

75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75

1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.67 1.67 1.67 1.67 2.33 2.33 2.33 2.33

Copper Foil & PCWB

Foamed PE

PVC

100

6.9 x 14.4

Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB Copper Foil & PCWB

Airspaced PE Airspaced PE Airspaced PE Foamed PE Foamed PE Foamed PE Foamed PE Foamed PE Airspaced PE Airspaced PE Foamed PE Foamed PE Airspaced PE Airspaced PE Foamed PE Foamed PE

PE LSHF PE/PP PE PE LSHF LSHF LDPE PE LDPE PE LSHF PE LDPE PE LSHF

69 69 90 69 80 69 69 90 115 130 115 115 135 147 135 135

8.0 8.0 9.5 8.0 25.5 8.0 8.0 9.5 10.1 11.3 10.1 10.1 12.7 14.4 12.7 12.7

BNC

F-Type

Crimp Tool

Crimp Plug

Crimp Jack

Right Angle Plug

Crimp Plug

Crimp Jack

YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1 YB1BC1

YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2 YB1BC2

YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8 YB1BC8

YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1 YB1FC1

YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2 YB1FC2

YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2

YB1BC1 YB2BC1 YB2BC1 YC1BC1 YB2BC1 YB2BC1 YB2BC1 YB2BC1 YC1BC1

YB1BC2 YB2BC2 YB2BC2 YC1BC2 YB2BC2 YB2BC2 YB2BC2 YB2BC2 YC1BC2

YB1BC8 -

YB1FC1 YB2FC1 YB2FC1 YC1FC1 YB2FC1 YB2FC1 YB2FC1 YB2FC1 YC1BC1

YB1FC2 YB2FC2 YB2FC2 YC1FC2 YB2FC2 YB2FC2 YB2FC2 YB2FC2 YC1BC2

YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2 YTC2

Low Smoke Halogen Free

Duct Grade

www.fscables.com

sales@fscables.com


37

Composite Coaxial COAXIAL Composite Coaxial Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

To meet the increasing demands for camera cables containing a coax with power and control cores for Pan, Tilt, Zoom (PTZ) or audio we are now stocking various types. These can either be within one circular jacket for easy glanding or in??????? a shotgun style with a web between the individual elements. Please call to discuss your requirements and ask for details or samples of the current stock range. Part No.

Description Coax

Construction

Power Cores

Signal Cores

Outer Sheath

Weight kg/km

O/D mm

3900592/2

RG59 B/U

2 x 1.5mm²

2 x 0.22mm²

Circular

PVC

185

12.0

3900592/2D

RG59 B/U

2 x 1.5mm²

2 x 0.22mm²

Circular Duct

LDPE

225

14.2

3900592/2H

RG59 B/U

2 x 1.5mm²

2 x 0.22mm²

Circular LSHF

LSHF

140

12.0

390059/2

RG59 B/U

2 x 0.75mm²

-

Shotgun

PVC

92

5.9 x 12.0

390059/3

RG59 B/U

3 x 0.5mm²

-

Shotgun

PVC

92

5.9 x 12.0 6.1 x 12.0

390059/2D

3900592/2

RG59 B/U

2 x 0.75mm²

-

Circular Duct

LDPE

110

390059-Shotgun

2 x RG59 B/U

-

-

Shotgun

PVC

102

6 x 12.4

390059H-Shotgun

2 x RG59 B/U

-

-

Shotgun

LSHF

102

6 x 12.4

URM 70

2 x 0.75mm²

-

Shotgun

PVC

98

6 x 12.0

Construction

Outer Sheath

Weight kg/km

O/D mm

391070/2 Part No.

Description Coax

Screen

390179Y3

3 x RG179

Unscreened

Circular

PVC

63

7.4

390179Y5F-S

5 x RG179

Overall Foil Screen

Circular

PVC

104

9.0

390179Y5FH-S

5 x RG179

Overall Foil Screen

Circular

LSHF

104

9.4

Description

BNC

F-Type

Crimp Plug

Crimp Jack

Twist-on Plug

3900592/2

YA1BC1

YA1BC2

YA1BT1

3900592/2D

YA1BC1

YA1BC2

YA1BT1

3900592/2H

YA1BC1

YA1BC2

390059/2

YA1BC1

390059/3 390059/2D

Boots

Crimp Plug

N-Type

TNC

Crimp Jack

Crimp Plug

Crimp Jack

Crimp Tool

Crimp Jack

Crimp Plug

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YA1BC1

YA1BC2

YA1BT2

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

YTC1

390059-Shotgun

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

390059H-Shotgun

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

391070/2

YA1BC1

YA1BC2

YA1BT1

YA1BX7xx YA1FC1

YA1FC2

YA1NC1 YA1NC2 YA1TC1

YA1TC2

390179Y3

YA7BC1

YA7BC2

-

YA7BX7xx YA7FC1

-

-

-

-

-

390179Y5F-S

YA7BC1

YA7BC2

-

YA7BX7xx YA7FC1

-

-

-

-

-

YTC1

390179Y5FH-S

YA7BC1

YA7BC2

-

YA7BX7xx YA7FC1

-

-

-

-

-

YTC1

Connectors

Low Smoke Halogen Free

White

Duct Grade

Tel: 01727 840 841

Fax : 01727 840 842

FS YTC1 YTC1

YTC1

FS YTC1

YTC1

cables YTC1 YTC1

FS

FS

FS

FS

cables

cables

04

cables

YTC1 cables

Black

FS

cables

00

cables

To show the colour required please replace xx in the part number with:

FS

YA1TC2

cables


38

COAXIAL Antennax Feeder Cables

Antennax Feeder Coax N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Antennax

The AntennaxTM range of high performance, ultra low loss coaxial cables are designed for interconnection of base stations, aerials and transceivers. Developed for microwave, satellite and telecommunication, Antennax coax cables are manufactured to guarantee high levels of performance across the broadband spectrum up to 5.8GHz. Antennax 50 Ohm & 75 Ohm coaxial cables can be used as a direct alternative to traditional corrugated cables while offering similar high performance, greater flexibility and faster termination with reduced risk of kinking.

The flexible braided design allows Antennax cables to be used throughout the installation, removing the need for jumper cables which are traditionally used to terminate corrugated coax cables. 75 Ohm versions are designed for use on wireless broadband video applications and specialised RF communications.

Part No.

Cable Type

Sheath Material

Size mm

Weight kg/km

O/D mm

Antennax 50 Ohm

390L40H

390L19 390L19H 390L20 390L20H 390L24

ANT-195

UV PE

1/0.94

30

4.95

ANT-195H

LSHF

1/0.94

30

4.95

ANT-200

UV PE

1/1.12

30

4.95

ANT-200H

LSHF

1/1.12

30

4.95

ANT-240

UV PE

1/1.42

50

6.1

ANT-240H

LSHF

1/1.42

50

6.1

ANT-300

UV PE

1/1.78

80

7.6

ANT-300H

LSHF

1/1.78

80

7.6

ANT-400

UV PE

1/2.74

100

10.3

ANT-400H

LSHF

1/2.74

100

10.3

ANT-600

UV PE

1/3.61

200

12.7

ANT-600H

LSHF

1/3.61

200

12.7

390L20H75

ANT-200H

LSHF

1/0.64

31

5.0

390L24H75

ANT-240H

LSHF

1/0.82

49

6.1

390L40H75

ANT-400H

LSHF

1/1.65

101

10.3

390L60H75

ANT-600H

LSHF

1/2.74

201

15.0

390L24H 390L30 390L30H 390L40 390L40H 390L60 390L60H Antennax 75 Ohm

cables

FS

FS cables

cables

FS

Full technical datasheets and test reports are available for each cable showing attenuation, return loss and resistance

FS cables

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


39

Antennax Connectors COAXIAL Antennax Feeder Coax N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The AntennaxTM connectors are matched perfectly with the cables and minimise loss and provide easy termination either in the field or on the assembly bench. To ensure reliable weatherproof terminations a full range of tools, boots, shrouds, self amalgamating tapes and weatherproof PVC tape is also available. It’s as important to us that your installation is reliable and trouble free as it is to you. If the connector type you need is not shown please ask us as we may well be able to supply it.

Female

N-Type Crimp Male

Crimp Tool

Stripping Tool

390L19 -CS7

390L24 -T1

390L24 S1

-

-

390L24 -T1

390L24 -S1

390L24 -CS1

390L24 -CS6

390L24 -CS7

390L24 -T1

390L24 -S1

-

-

-

-

390L30 -T1

390L40 S1

390L40 -CT6

390L40 -CT7

390L40 -CS1

390L40 -CS6

390L40 -CN7

390L40 -T1

390L40 -S1

390L60 -CT6

390L60 -CT7

-

-

-

390L60 TS1

-

-

-

-

-

-

cables

BNC Crimp Male

TNC Crimp

SMA Crimp

-

-

-

-

-

FS

-

-

-

-

Female

Right Angle Male

Male

Female

Reverse Polarity Male

Reverse Polarity Female

Male

Reverse Polarity Male

Reverse Polarity Female

390L19 -CN1

390L19 -CN2

390L19 -CN3

-

-

-

-

-

390L19 -CS6

390L20 390L20 -CB1 -CB2

390L20 -CN1

390L20 -CN2

390L20 -CN3

390L20 390L20 -CT1 -CT2

390L20 -CT6

390L20 -CT7

-

390L24 390L24 -CB1 -CB2

390L24 -CN1

390L24 -CN2

390L24 -CN3

390L24 390L24 -CT1 -CT2

390L24 -CT6

390L24 -CT7

-

390L30 -CN1

390L30 -CN2

-

-

390L40 -CN1

390L40 -CN2

390L40 -CN3

390L60 -CN1

390L60 -CN2

-

Connectors & Accessories -

-

-

390L40 390L40 -CB1 -CB1

-

-

390L40 390L40 -CT1 -CT2

-

-

-

-

-

390L2075 390L2075 -CN1 -CN2

-

390L2075 -CT1

390L2075 -CT2

-

-

-

-

-

390L2475 390L2475 -CN1 -CN2

-

390L2475 -CT1

390L2475 -CT2

-

-

-

-

-

390L4075 390L4075 -CN1 -CN2

-

390L4075 -CT1

390L4075 -CT2

-

-

-

-

-

390L6075 390L6075 -CN1 -CN2

-

390L6075 390L6075 -CT1 -CT2

-

-

-

FS

-

cables

-

-

cables

FS

FS

FS

FS

FS

cables

cables

cables

FS

Please note ANT-600 connectors are clamp style

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


40

HOME AUTOMATION HD Media Composite Cables

HD Media Composite Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Developed to carry HD Video, HDMI and high speed data, all the components in these cables have been developed with both the present and future in mind. By combining all elements within a single tough jacket these HD Media Composite Cables are far less likely to get kinked or damaged during installation and allow general electrical contracting labour to pull in the carcass wiring. The distinctive jacket colour of these cables also enables quick and easy identification. The coaxial cables use a pure copper core with high braid coverage and bonded aluminium foil tape to give outstanding screening performance. The Cat-5 and Cat-6 cables carry signals at rates far in excess of the standard which allows for large file transfer between devices quickly and without corruption. Additionally, with cables containing fibre or building control elements such as KNX, Crestron™, Mode™ or Lutron™ you can be confident that the future is available now. Cables are printed with the area and device numbers on the jacket to make marking or tagging during installation quick and simple. If you have a specific requirement that is not shown please ask as it may have been added since the catalogue was printed. It may also be possible to manufacture it to your requirement in small quantities and with a lead time of only a few weeks.

HD Media Composite Cables

HA1

cables

FS

FS

HA1

HA2

HA3

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Blue Cat 5E UTP 1 x Red Cat 5E UTP Pink Overall PVC Sheath with a White Stripe Overall Diameter: 16.8mm Weight: 210kg/km

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Blue Cat 5E UTP 1 x Red Cat 5E UTP 1 x Grey building Control & Lighting Cable Pink Overall PVC Sheath with a Blue Stripe Overall Diameter: 19.5mm Weight: 270kg/km

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP Pink Overall PVC Sheath with a Black Stripe Overall Diameter: 17.3mm Weight: 220kg/km

HA4

HA5

HA6

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Blue Cat 5E UTP Pink Overall PVC Sheath with a Green Stripe Overall Diameter: 18.7 Weight: 250kg/km

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Blue Cat 5E UTP Pink Overall LSHF Sheath with a Violet Stripe Overall Diameter: 18.7 Weight: 250kg/km

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Orange Fibre Pink Overall PVC Sheath with a Brown Stripe Overall Diameter: 16.6mm Weight: 235kg/km

cables

HA7

cables

FS

FS cables

1 x Black Coaxial Cable 1 x White Coaxial Cable 1 x Grey Cat 6 UTP 1 x Violet Cat 6 UTP 1 x Green KNX Pink Overall PVC Sheath with a Yellow Stripe Overall Diameter: 18.4mm Weight: 260kg/km

www.fscables.com

sales@fscables.com


41

HD Media Composite Cables HOME AUTOMATION Technical Specifications for each element Coaxial Cable Conductor: Dielectric: 1st Screen: 2nd Screen: 3rd Screen: 4th Screen: Sheath:

Bare Copper Foamed PE Bonded Aluminium Foil Aluminium Wire Braid Aluminium Foil Aluminium Wire Braid PVC

Overall Diameter: 7.54mm Impedance: 75 Ohm Nominal Capacitance: 52 pF/Ft ±3 Velocity: 85% Return Loss: ≥ 20dB

Attenuation: 55MHz 5.25 dB/100m 450MHz 14.43 dB/100m 1000MHz 21.49 dB/100m 1800MHz 27.73 dB/100m 3000MHz 37.50 dB/100m

Overall diameter: Impedance:

5.3mm 100 Ohm ±15

Attenuation: 1MHz 2.0 dB/100m 4MHz 4.1 dB/100m 10MHz 6.5 dB/100m 16MHz 8.2 dB/100m 20MHz 9.3 dB/100m 31.25MHz 11.7 dB/100m 62.5MHz 17.0 dB/100m 100MHz 22.0 dB/100m

Overall diameter: Impedance:

6.4mm 100 Ohm ±15

Attenuation: 1MHz 1.9 dB/100m 4MHz 3.7 dB/100m 10MHz 5.9 dB/100m 16MHz 7.5 dB/100m 20MHz 8.4 dB/100m 31.25MHz 10.6 dB/100m 62.5MHz 15.4 dB/100m 100MHz 19.8 dB/100m 155MHz 25.1 dB/100m 200MHz 29.0 dB/100m 250MHz 32.8 dB/100m

HA5

Cat 5E 4Pair UTP PVC Conductor: Solid bare copper 0.51mm Insulation: PE Sheath: PVC Complies to TIA/EIA 568B & ISO/IEC 11801

Cat 6 4Pair UTP PVC Conductor: Solid bare copper 0.570mm Insulation: PE Sheath: PVC

Complies to TIA/EIA 568B & ISO/IEC 11801

No. of Fibres:

4

FS

Fibre Size:

50/125µ

Other fibre combinations and sizes are available to order including 9/125 & 62.5/125, please contact us for more details.

FS

FS

cables

cables

FS

cables

Fibre

cables

Building Control Lighting Cable Conductor: Insulation: Sheath:

22(7)AWG tinned copper PE Foil screened pair with drain wire

Tel: 01727 840 841

18(7) AWG tinned copper PVC PVC

Fax : 01727 840 842

FS

FS

FS

FS

cables

cables

Power Cores – Black & Red

Conductor: Insulation: Screen:

cables

Data Pair – White & blue

cables


42

BUS Industrial & Building Control Databus速 Foundation Fieldbus ISA/SP-50 Profibus PA Type A A single pair 18AWG bi-directional digital Fieldbus cable for type A applications (31.25 KBits/sec) available in PVC, LSHF and SWA versions. Part No.

1801POFOH 1801PODF 1801POFO 1801POFOH 1801POFOA

Alt. to Belden

No. of Pairs

AWG

Sheath Material

Weight kg/km

O/D mm

Screened

Sheath Colour

3076F LSHF SWA

1 1 1 1

18(1) 18(7) 18(7) 18(7)

PVC PVC LSHF SWA/PE

75 51 51 246

8.0 6.4 6.4 9.6

Yes Yes Yes Yes

Blue Orange Orange Black

Databus速 Foundation Fieldbus ISA/SP-50 Type B A single pair 22AWG bi-directional digital Fieldbus cable for type B applications (31.25 KBits/sec) available in PVC, LSHF and SWA versions. Part No.

Alt. to Belden

No. of Pairs

AWG

Sheath Material

Weight kg/km

O/D mm

Screened

2201POFO 2201POFOH 2201POFOA

3077F LSHF SWA

1 1 1

22(7) 22(7) 22(7)

PVC LSHF SWA/PE

29 29 213

4.9 4.9 8.1

Yes Yes Yes

Databus速 Foundation Fieldbus ISA/SP-50 High Speed A high speed single pair 22AWG bi-directional digital Fieldbus cable for 1.0 & 2.5MBit/sec applications available in PVC, LSHF and SWA versions.

cables

FS

FS cables

cables

FS

FS cables

Part No.

Alt. to Belden

No. of Pairs

AWG

Sheath Material

Weight kg/km

O/D mm

Screened

2201POFF 2201POFFH 2201POFFA

3078F LSHF SWA

1 1 1

22(7) 22(7) 22(7)

PVC LSHF SWA/PE

65 65 287

9.4 9.4 12.6

Yes Yes Yes

CAN Bus Cables CAN Bus (Control Area Network) is a non-addressable system which treats all devices as equal allowing for fast transmission of data. Due to its robust nature it has been widely adopted in the automotive industry. While all the types listed below are for high flexing automation applications, static versions can also be supplied. Part No.

28100201 28100202 28100301 28100302 28100501 28100502

No. of Pairs

CSA mm2

Sheath Material

Weight kg/km

O/D mm

Screened

1 2 1 2 1 2

0.22 0.22 0.34 0.34 0.50 0.50

PUR PUR PUR PUR PUR PUR

41 60 53 64 67 75

5.2 8.0 5.9 6.5 7.2 9.0

Yes Yes Yes Yes Yes Yes

Low Smoke Halogen Free

SWA

www.fscables.com

sales@fscables.com


43

Industrial & Building Control BUS CC-Link 1.10 FieldLink® Cables Developed by Mitsubishi, CC-Link allows high speed communication between controllers and field devices. CC-Link is particularly popular in Asia and is used worldwide for time critical applications in conjunction with Mitsubishi Automation products. CC-Link is certified by CLPA and ensures product compatibility. Part No.

2003CODF-03 2003CODFA

Alt. to Belden

No. of Cores

AWG

Sheath Material

Weight kg/km

O/D mm

Screened

YR47205 SWA

3 3

20 20

PVC SWA/PE

186 276

7.6 12.0

Yes Yes

2003CODF-03

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC DeviceNet™ Thick Cables 60331)

Designed for use on Allen Bradley DeviceNet systems, the ‘thick’ cable construction incorporates a power and data pair for backbone wiring. Several sheathing options are available for different installation environments. These cables are also referred to as DeviceNet Trunk cables. Part No.

15ABDY 15ABDR 15ABDYA 15ABDY-HF

Alt. to Belden

3082A 3083A SWA Hi-FLEX

Pairs x AWG

P: 1Px15 P: 1Px15 P: 1Px15 P: 1Px15

D: 1Px18 D: 1Px18 D: 1Px18 D: 1Px18

Sheath Material

Weight kg/km

PVC CPE SWA/PE PUR

174 174 359 209

O/D mm

Appl.

12.2 Static 12.1 Static 16.1 Static 12.1 Dynamic

Screened

Yes Yes Yes Yes

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC DeviceNet™ Thin Cables 60331) ‘Thin’ cables are designed to connect sensors, actuators and switches to the DeviceNet backbone

15ABDY

(thick cable) on the Allen Bradley DeviceNet system. Similar in construction to the backbone cable, the ‘thin’ cable incorporates a power and data pair. Several sheathing options are available for different installation environments. These cables are also referred to as DeviceNet Drop cables.

22ABDY 3084A 22ABDR 3085A 22ABDYA SWA 22ABDY-HF Hi-FLEX

Pairs x AWG

P: 1Px22 P: 1Px22 P: 1Px22 P: 1Px22

D: 1Px24 D: 1Px24 D: 1Px24 D: 1Px24

Sheath Material

Weight kg/km

O/D mm

PVC CPE SWA/PE PUR

65 68 240 64

7.0 7.1 11.9 7.0

Appl.

Static Static Static Dynamic

FS

Screened

Yes Yes Yes Yes

FS

cables

FS

FS

FS

FS

FS

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

SWA

FS

cables

Alt. to Belden

cables

Part No.

cables


44

BUS Industrial & Building Control Bus Cables Echelon LonWork System Cabling

2202POFGH

A range of single pair Bus cables is available for the LonWork’s system allowing convenient wiring via the Free Topology concept. Due to the popularity of the system for building management applications in the public sector these cables are now stocked in Low Smoke Halogen Free versions. Duct grade and SWA options can also be manufactured for quantities as low as 100m. Part No.

Alt. to Belden

No. of Pairs

AWG

Sheath Material

1601PUY 1601PUYH 1601PUYD 1601PUYA

8471 LSHF DUCT SWA

1 1 1 1

16(19) 16(19) 16(19) 16(19)

Weight kg/km

PVC LSHF LDPE PE

56 56 89 280

O/D mm

Screened

7.0 7.0 9.5 10.8

No No No No

Echelon LonWork System Cabling Designed for use on industrial and commercial Bus systems, these cables have become increasingly popular on Building Management Systems (BMS). Available as one and two pair cables, screened and unscreened in Low Smoke Halogen Free, they provide the ideal low cost solution to Bus wiring. Part No.

2201PUGH 2202PUGH 2201POFGH 2202POFGH

C5S-HF

Alt. to Belden

No. of Pairs

AWG

7701NH 7702NH 7703NH 7704NH

1 2 1 2

22(1) 22(1) 22(1) 22(1)

Sheath Material

LSHF LSHF LSHF LSHF

Weight kg/km

O/D mm

Screened

14 27 23 36

3.5 5.0 4.5 6.5

No No Yes Yes

N2XCH-FE180/E90: Screened, Industrial EthernetXLPE/Cu/LSHF Cables to IEEE 802.3 Fire Resistant (IEC 60331)

Through the use of Category 5 style cables Industrial Ethernet provides a stable platform for linking automation systems and workstations. They are also suitable for interlinking different Bus protocols such as Profibus and Interbus. The use of finely stranded conductors and PUR sheathing compounds makes them ideal for frequent flexing and dynamic applications.

cables

FS

FS cables

Part No.

C52S-HF C5S-HF

No. of Pairs

AWG

Sheath Material

Weight kg/km

O/D mm

Screened

2 4

24(19) 24(19)

PUR PUR

65 82

6.1 8.0

Yes Yes

Interbus Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC The Interbus open ring topology allows integration of different field devices from control level down 60331) to sensor switches over one system. Unlike traditional ring systems Interbus uses one cable to route data back and forth to all devices. Each device or unit will amplify the signal before sending it on to the next station. The data is transmitted over a 3 pair screened cable. For remote applications a composite data and power cable is available.

cables

FS

FS cables

Part No.

2403POBP 2403POBP-HF 2403/3POBP-HF

Alt. to Belden

Pair x mm2

Sheath Material

O/D mm

Application

Screened

PVC PUR PUR

8.0 8.2 9.3

Static Dynamic Dynamic with remote power

Yes Yes Yes

N/A 3P x 0.22 3102A 3P x 0.22 3119A 3P x 0.22 + 3C 1.0

Low Smoke Halogen Free

Duct Grade

SWA

www.fscables.com

sales@fscables.com


45

Industrial & Building Control Bus Cables BUS Modbus Developed by Modicon, Modbus provides a master/slave communication between intelligent automation devices. Based on Belden 9841, the Modbus cable has an increased jacket thickness to ensure a correct termination into the Modbus connectors.

2201PODF Part No.

Alt. to Belden

2401POHP+ YM29560 2401POHPH+ LSHF

No. of Pairs

AWG

Sheath Material

Sheath Colour

Weight kg/km

O/D mm

Screened

1 1

24(7) 24(7)

PVC LSHF

Grey Grey

63 63

6.7 6.7

Yes Yes

Profibus DP IEC 61158/EN 50170 SINEC L2 A range of single pair Bus cables for process and field communication in cell networks. The Profibus protocol has been widely adopted for production and process automation applications providing transmission rates up to 12Mbits/sec. Part No.

Alt. to Belden

No. of Cond Pairs mm

2201PODF 3079A 2201PODFHA SWA 2201PODFHQ LSHF 2201PODFD DUCT 2201PODFHF Hi-FLEX 2201PODF7 3079E 2201PODFHT HiTEMP

1 1 1 1 1 1 1

0.64 0.64 0.64 0.64 0.64 0.64 0.64

Sheath Material

Sheath FastConn/ Weight Colour Quickstrip kg/km

PVC LSHF LSHF LDPE PUR PVC FEP

Violet Black Violet Black Violet Violet Violet

Yes No Yes No No No No

62 188 64 88 78 65 64

O/D mm

Application

8.0 Static 11.5 Static 8.0 Static 9.5 Wet/outdoor static 8.3 Dynamic 8.0 European type static 7.2 High Temperature

28100703

N2XCH-FE180/E90: Pilz Safety Bus p XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) ® ®

No. of Cores

28100703 28100703H 28100703-HF

3 3 3

CSA mm2

0.75 0.75 0.75

FS

Sheath Material

Sheath Colour

Weight kg/km

O/D mm

Application

PVC LSHF PUR

Yellow Yellow Yellow

89 89 89

7.5 7.5 7.5

Light Flexing Light Flexing Dynamic

cables

Part No.

FS

cables

Safety Bus p is an open Fieldbus system based on well established CAN Bus technology. Safety Bus p® modules must be self monitoring, perform intelligent checks and react independently, therefore remaining ‘safe’. Several versions of Safety Bus p® cables are available depending on the application and environmental conditions.

cables

FS

FS

FS

FS

FS

cables

cables

cables

FS

All trademarks & tradenames are acknowledged. Low Smoke Halogen Free

Duct Grade

Tel: 01727 840 841

SWA

Fax : 01727 840 842

cables

cables


46

BUS System Specific Lighting Control Cables Lutron GRX-CBL-346S Grafik Eye Cables

18/22LCCH

Lutron are world leaders in lighting control systems for prestige residential properties as well as restaurant, retail and commercial applications. In addition to the full range of genuine Lutron cables we are also able to offer a high quality alternative to the GRX-CBL-346S for the GRAFIK Eye® 3000, 4000, 5000 & 6000 systems manufactured using Low Smoke Halogen Free materials throughout. This enables installations in locations that prohibit the use of standard PVC types. Where the cable is run outside duct grade and armoured versions are also popular.

Cable Construction - Power Pair

Technical Information

Conductors: Insulation:

Voltage Rating: Test Voltage: Temperature Rating: Smoke Emission: Halogen Emission:

Colour code: Conductor resistance:

18(7)AWG tinned copper strands Polypropylene insulation – 1.97mm nominal Red & black 23 Ohm/km @ 20°C

300V 1.5kV 0°C to +70°C IEC 61034-1 & 2 IEC 60754-1 & 2

Cable Construction - Data Pair Conductors: Insulation:

22(7)AWG tinned copper strands Polypropylene insulation – 1.83mm nominal Aluminium/polyester screen and 24(7)AWG TCu drain wire Purple & white 58 Ohm/km @ 20°C Core to core 45pF/m nominal 120 Ohm nominal

Screen: Colour code: Conductor resistance: Capacitance: Impedance:

Pair bundles laid up with polyester fillers, polyester tape, blue LSHF sheath.

18/22ECCH

cables

FS

FS cables

cables

FS

FS cables

Part No.

Alternative to

Sheath Colour

O/D mm

Weight kg/km

18/22LCCH 18/22LCCHD 18/22LCCHA

Lutron GRX CBL-346S Duct Grade SWA/PE

Blue Black Black

8.4 10.8 12.3

72 123 259

Mode Lighting Cable N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC If you are installing a Mode Lighting Evolution system we offer an alternative to Belden 1502R. 60331) The cable is electrically the same as the Lutron type above but uses a PVC jacket with a reduced overall diameter for easy routing. Part No.

18/22ECC 18/22ECCH 18/22ECCD 18/22ECCA

Alternative to

Sheath Colour

O/D mm

Weight kg/km

Blue Blue Black Black

6.4 6.4 8.7 10.5

65 65 89 223

Belden 1502R LSHF Duct Grade SWA/PE

Low Smoke Halogen Free

Duct Grade

SWA

www.fscables.com

sales@fscables.com


47

KNX BUS

With the increasing demand for ‘green’ buildings, Intelligent Building Technology systems can contribute to significant energy savings over time. The operation and control of heating, lighting and air condition among others can be aligned with external climate conditions or adjusted by an interface to pre-set levels.

31000502H

FS Cables as member of the KNX association now offers KNX certified cable. This features two twisted pairs of solid conductor with a foil screen and tinned copper drain wire in a green LSHF jacket. It has been tested and certified as being suitable for use in KNX systems and bears the KNX logo. All KNX certified equipment has been tested and certified to meet this high standard and only equipment meeting this can carry the logo. This ensures the quality, reliability and guaranteed compatibility of all KNX devices and equipment.

Part No.

No. of Pairs

Conductor mm

Sheath Colour

Weight kg/km

O/D mm

KNX Reg No

KNX Cable 31000501QH

1 Quad

0.8

Green

57

6.2

N/A

31000502H

2

0.8

Green

62

6.8

150/8928/10

31000502H04

2

0.8

White

62

6.8

150/8928/10

31000502D

2

0.8

Black

95

9.2

150/8928/10

31000502A

2

0.8

Black

300

13.0

150/8928/10

No. of Pairs

Conductor mm

31000501*

1

0.8

31000501H

1

0.8

31000501H190

1

0.8

31000501H320

1

0.8

Part No.

Sheath Colour

Sheath Material

Length

O/D mm

Grey

PVC

Bulk

5.9

Green

LSHF

Bulk

5.2

Green

LSHF

190mm

5.2

Green

LSHF

320mm

5.2

31000502A

KNX Jumper Cables

FS

FS

cables

FS

FS

FS

FS

FS

Duct Grade

Tel: 01727 840 841

SWA

Fax : 01727 840 842

cables

cables

cables

cables

Low Smoke Halogen Free

cables

FS

cables

* This jumper cable has the colour code of black & red.

cables


48

BUS Simmtronic Specs 3 Simmtronic Specs 3 & Lighting Multicores

1801PUYH-01

FS Cables are the sole appointed supplier of the Simmtronic SPECS3 cables. Manufactured to very high tolerances using Low Smoke Halogen Free compounds throughout you can be confident the cable will fit the connectors first time and every time, resulting in a trouble free installation you can rely on. Be careful of imitations, only use the authentic Simmtronic Specs 3 cable printed with the Simmtronic logo. For more information, please go to www.simmtronic.com or call 01992 456 869.

Construction

Plain copper wire strands, class 5 to BS6360, LSHF insulation - colour coded, LSHF sheath - White. 300/500V. -20째C to +90째C static.

C-Bus grey 2201POFPH-05 1 pair 22AWG screened cable for connection of SPX 310 area controllers and SPG.2 gateway modules. Low Smoke Halogen Free throughout. 1801PUYH-04

E-Bus white 1801PUYH-04 1 pair 18AWG unscreened cable for connection of intelligent remote devices to SPX 310 area controllers and SPV.9 lighting control modules. Low Smoke Halogen Free throughout.

O-Bus/M-Bus pink 1801PUYH-07 1 pair 18AWG unscreened cable for communications from the SPX 310 area controller and the SPV.9 lighting control modules. Low Smoke Halogen Free throughout.

E-Bus blue 1801PUYH-01 1 pair 18AWG unscreened cable. Colour coded blue for fast identification this version of E-Bus provides emergency monitoring signals to the SPX 310 area controller or for identification of specific circuits spec 3 system. Low Smoke Halogen Free throughout.

T-Bus grey cables

FS

1801PUYH-07

FS cables

cables

FS

FS cables

2202PTFRH 2 pair 22AWG individual and overall foil screen for dual connections of SPX310 area controllers and SPG.2 gateway modules. Low Smoke Halogen Free throughout.

SPV.9 Plug wiring A full range of Low Smoke Halogen Free flexible cables are available from stock for wiring three and six pin Ensto plugs allowing fast onsite installation. Stocked in either 1mm2 or 1.5mm2. Part No.

31801003 31801503 31801004 31801504 31801005 31801505 31801006 31801506

Cores x mm2

Weight kg/km

O/D mm

3 x 1.0 3 x 1.5 4 x 1.0 4 x 1.5 5 x 1.0 5 x 1.5 6 x 1.0 6 x 1.5

84 120 106 152 134 183 163 201

7.1 8.3 7.9 9.4 8.7 9.4 9.8 10.1

www.fscables.com

sales@fscables.com


49

AUDIO TruSound Microphone & Snake Cables Microphone Cables

Microphone cables come in many shapes and sizes. Super flexibility even at low temperatures is achieved through the use of a special insulation and highly flexible cotton fillers to maintain a constant capacitance and avoid noise when the cable flexes. The spiral copper shield offers excellent screening whilst remaining flexible and providing mechanical support when the cable is under physical stress. The four core microphone cables are a star quad format.

Part No.

Cores x mm2

Stranding No. x mm

Weight kg/km

O/D mm

Colour

TSM02020

2 x 0.22

28 x 0.10

45

5.9

Black

TSM02040

4 x 0.22

28 x 0.10

55

6.5

Black

TSM03020

2 x 0.34

40 x 0.10

52

6.2

Black

TSM03040

4 x 0.34

40 x 0.10

64

6.8

Black

TSM05020

2 x 0.50

28 x 0.15

65

6.7

Black

TSM05040

4 x 0.50

28 x 0.15

75

7.2

Black

TSM02020

Multiple Star Quad Cables Designed for longer runs where it is beneficial to run a number of signals down a single cable using the star quad format. These cables are highly flexible and robust enough for touring applications. Cores x mm2

Stranding No. x mm

Screening

Weight kg/km

O/D mm

Colour

TSQ01010

1 x 4 x 0.15

19 x 0.10

Overall Braid

45

5.5

Black

TSQ02010

1 x 4 x 0.22

28 x 0.10

Overall Braid

60

6.5

Black

TSQ01040

4 x 4 x 0.15

19 x 0.10

Overall Braid

180

11.7

Black

TSQ01080

8 x 4 x 0.15

19 x 0.10

Overall Braid

280

14.9

Black

TSQ01012

12 x 4 x 0.15

19 x 0.10

Overall Braid

420

18.2

Black

TSQ01024

24 x 4 x 0.15

19 x 0.10

Overall Braid

780

25.0

Black

TSQ01010H

1 x 4 x 0.18

7 x 0.18

Overall Foil

50

4.7

Black

TSQ05010H

1 x 4 x 0.50

28 x 0.15

Overall Braid

60

6.5

Black

TSQ01040H

4 x 4 x 0.18

7 x 0.18

Overall Foil

150

11.4

Grey

TSQ01080H

8 x 4 x 0.18

7 x 0.18

Overall Foil

290

15.5

Grey

TSQ01012H

12 x 4 x 0.18

7 x 0.18

Overall Foil

425

19.3

Grey

LSHF versions are also offered for use in sensitive areas or where local regulations permit.

cables

Multipair versions up to 30 pair are available with or without individual pair screens.

FS

FS

cables

Part No.

FS

cables

FS

FS

FS

FS

FS

cables

Snake cables are shown on page 52.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

Low Smoke Halogen Free

cables


50

AUDIO TruSound Parallel Speaker Cable Parallel Speaker Cables

TS804002

Designed for installations in pubs, clubs, gyms and public buildings as well as high end domestic installations, these parallel speaker cables provide easy termination due to the longitudinal core identification. The high number of pure copper strands and low resistance values enable the speaker to operate at optimum levels. The question when specifying is to check the purity of the copper as it is this which gives the lowest resistance figure. In TruSound speaker cables only pure electrolytic copper is used so it can be classed as OFC (Oxygen Free Copper).

Technical Information Minimum Bend Radius: 5 x cable thickness Part No.

Size mm2

Stranding No. x mm

Weight kg/km

O/D mm

Cond. Resistance Ohm/km

Cap pF/m

Test Voltage

Colour

TruSound Parallel Speaker Cable TS800702

0.75

24 x 0.2

23

2.3 x 4.9

26.0

82

2kV

Clear

TS801502

1.5

189 x 0.1

42

2.8 x 5.8

13.3

67

2kV

Clear

TS802502

2.5

322 x 0.1

60

3.6 x 7.4

7.98

57

2kV

Clear

TS804002

4.0

511 x 0.1

105

4.5 x 9.7

4.95

54

2kV

Clear

TS806002

6.0

777 x 0.1

141

6.1 x 12.5

3.3

58

2kV

Clear

TS810002

10.0

1260 x 0.1

252

7.0 x 15.0

1.91

62

2kV

Clear

TruSound Low Smoke Halogen Free Parallel Speaker Cables TS800702H

0.75

24 x 0.2

23

2.3 x 4.9

26.0

82

2kV

White

TS801502H

1.5

189 x 0.1

42

2.8 x 5.8

13.3

67

2kV

White

TS802502H

2.5

322 x 0.1

60

3.6 x 7.4

7.98

57

2kV

White

TS802502H

Flat Speaker Cable

cables

FS

Low profile speaker cable, suitable for laying under carpet, behind decorative moulding, along the ceiling or under furniture. Suitable for fixed installations, this cable uses flexible PVC insulation making it easily routable. Part No.

Size mm2

Stranding No. x mm

Weight kg/km

O/D mm

Cond. Resistance Ohm/Km

Colour

TruSound Flat Speaker Cable

FS cables

TSF01502

1.5

47 x 4 x 0.1

53

12.8 x 2.4

<13.3

White

TSF02502

2.5

80 x 4 x 0.1

60

14.6 x 2.6

<7.98

White

TSF04002

4.0

125 x 4 x 0.1

108

17.5 x 0.3

<4.95

White

cables

FS

FS cables

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


51

TruSound Multicore Speaker Cable AUDIO Multicore Speaker Cable Designed for the professional these multicore speaker cables are extremely flexible due to the high rate of conductor twist and the insulation and jacket materials used. Ideal for winding on and off drums when touring, they even remain flexible at low temperatures making rigging easier. They are also ideal for large fixed installations where sound quality is important.

TSS02504

The range of conductor sizes enables long runs, or shorter runs with very low power loss.

Part No.

Cores x mm2

Stranding No. x mm

Weight kg/km

O/D mm

Cond. Resistance Ohm/km

7.0

<14

Test Voltage

Colour

TruSound Multicore Speaker Cables - Circular TSS01502

2 x 1.5

30 x 0.20

75

2kV

Black

TSS01504

4 x 1.5

30 x 0.20

120

8.6

<14

2kV

Black

TSS02502

2 x 2.5

50 x 0.25

90

7.5

<8

2kV

Black

TSS02504

4 x 2.5

50 x 0.25

175

10.0

<8

2kV

Black

TSS02508

8 x 2.5

50 x 0.25

330

14.0

<8

2kV

Black

TSS04002

2 x 4.0

56 x 0.30

170

10.5

<5

2kV

Black

TSS04004

4 x 4.0

56 x 0.30

265

13.0

<5

2kV

Black

TSS04008

8 x 4.0

56 x 0.30

495

18.5

<5

2kV

Black

TruSound Low Smoke Halogen Free Multicore Speaker Cables - Circular TSS01502H

2 x 1.5

30 x 0.25

65

7.0

<14

2kV

Black

TSS02502H

2 x 2.5

TSS02504H

4 x 2.5

50 x 0.25

85

7.6

<8

2kV

Black

50 x 0.25

145

8.8

<8

2kV

Black

TSS02508H

8 x 2.5

50 x 0.25

300

12.8

<8

2kV

Black

TSS04002H

2 x 4.0

56 x 0.30

125

9.2

<5

2kV

Black

TSS04004H

4 x 4.0

56 x 0.30

223

10.7

<5

2kV

Black

TSS06002H

2 x 6.0

84 x 0.30

170

10.6

<3

2kV

Black

FS

cables

FS

FS

FS

FS

FS

cables

FS

cables

FS

cables

Colour Code - Multicore Circular Speaker Cable: 01

Red

02

Blue

White

Cables with 7 cores and above are number coded

Low Smoke Halogen Free

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

Black

04

cables

03

cables


52

AUDIO TruSound Snake & DMX Cables Snake Cables Snake cables are multicore audio cables usually linking a number of individual microphone cables or audio feeds back to the mixing desk. Ideal for either fixed installation in permanent venues or on temporary installations when the cables will be coiled up and stored after the show.

TSD02010 Part No.

Pairs x AWG

Stranding No. x mm

Weight kg/km

O/D mm

Colour

TSSN0202

2 x 2 x 24

7 x 0.20

68

8.1

Black

TSSN0204

4 x 2 x 24

7 x 0.20

96

8.9

Black

TSSN0208

8 x 2 x 24

7 x 0.20

183

12.1

Black

TSSN0212

12 x 2 x 24

7 x 0.20

243

14.3

Black

TSSN0216

16 x 2 x 24

7 x 0.20

319

16.6

Black

TSSN0220

20 x 2 x 24

7 x 0.20

420

19.0

Black

TSSN0224

24 x 2 x 24

7 x 0.20

486

22.1

Black

TSSN0232

32 x 2 x 24

7 x 0.20

610

24.3

Black

TSSN0240

40 x 2 x 24

7 x 0.20

780

25.8

Black

TSSN0108Q

8 x 4 x 28

7 x 0.127

255

15.1

Black

DMX Cables Developed to ensure accurate transmission of digital AES/EBU audio signals and digital DMX control signals, these cables are used extensively in the entertainment industry. DMX is designed to work between 90立 and 120立 impedance. The level of shielding enables interference-free transmission even over long distances. The tough physical properties of the TruSound DMX cable make it one of the best products on the market.

Part No.

cables

FS

FS

Pairs x mm2

No. of Power Cores x mm2

Weight kg/km

O/D mm

Colour

Black

TSD02010

1 x 2 x 0.22

-

50

6.0

TSD02011

1 x 2 x 0.22

-

50

6.0

Blue

TSD02020

2 x 2 x 0.22

-

75

8.0

Black

TSD02150

1 x 2 x 0.22

3 x 1.5

175

11.6

Black

TSD02250

1 x 2 x 0.22

3 x 2.5

220

13.3

Black

TSD02270

2 x 2 x 0.22

3 x 2.5

380

18.3

Black

TSD021110

4 x 2 x 0.22

3 x 1.5

375

17.4

Black

TSD022110

4 x 2 x 0.22

3 x 2.5

460

19.3

Black

cables

cables

FS

Please note some of the cables above are also available in Low Smoke Halogen Free.

FS cables

www.fscables.com

sales@fscables.com


53

TruSound S-Video & HDMI Cables AUDIO S-Video Cable Using two coaxial cables within one jacket this flexible S-Video cable is suitable for connection of cameras, computers, audio, video & TV units. Each coax is screened with an aluminium foil and high coverage tinned copper wire braid and coloured pvc jacket for easy identification.

TSSV0802 Construction

Technical Information

Fine tinned copper strands 28(7)AWG, foam

Impedance: Capacitance Core to Screen: Temperature Range:

polyethylene insulation, aluminium foil, tinned

75 Ohms +/- 3% 64 pF/m -15°c to +70°C

copper wire braid, PVC jacket. Two cables laid together and circular black PVC sheathed. Part No.

Cores x mm2

Stranding

Weight kg/km

O/D mm

Colour

2 x 0.08

7 x 0.12

70

7.5

Black

TruSound S-Video TSSV0802

HDMI Cable The FSC range of high quality HDMI cables offer a quick and easy way to link devices throughout a building. Supplied either as bulk cables or more convenient to use, made up leads. You can be sure of a clear signal transmission.

Construction

TSHMM02

Fine tinned copper strands 24(7)AWG, foam polyethylene insulation, cores twisted into pairs, each pair overall foil screened in contact with tinned copper drain wire. Fine tinned copper strands 24(7)AWG, polypropylene insulation. Pairs and cores laid together, overall aluminium foil screen and overall tinned copper wire braid, PVC black sheath. Part No.

Weight kg/km

O/D mm

Colour

4 x 2 x 0.22mm² + 7 x 0.22mm²

130

10.0

Black

HDMI plug with solder pins

-

-

-

TSH00215 TSH00215-C1 Part No.

TSHMM02

HDMI 1.3 Male to HDMI 1.3 Male

2m

TSHMM03

HDMI 1.3 Male to HDMI 1.3 Male

3m

TSHMM05

HDMI 1.3 Male to HDMI 1.3 Male

5m

TSHMM10

HDMI 1.3 Male to HDMI 1.3 Male

10m

TSHMM15

HDMI 1.3 Male to HDMI 1.3 Male

15m

TSHMM20

HDMI 1.3 Male to HDMI 1.3 Male

20m

TruSound HDMI Pre-Made Leads

Tel: 01727 840 841

Fax : 01727 840 842

FS

FS

cables

FS

FS

FS

FS

FS

cables

cables

cables

Length

cables

Description

cables

FS

TruSound HDMI Cable & Plug

cables

Description

cables


54

FIRE & SECURITY Fire Alarm Cable

Fire Alarm Cable Standard & Enhanced It is now recognised that in some buildings the continued functioning or circuit integrity of some cables is essential in providing sufficient time for evacuation. The requirements divide ‘soft skin’ cables into 2 groups, Standard and Enhanced. The ‘enhanced’ versions shown below are suitable for installation where evacuation may be delayed, for example in hospitals or high-rise buildings without sprinklers. The ‘enhanced’ group of cables offer a viable alternative to MICC (Mineral Insulated Copper Clad) in many applications with the benefit of faster installation and easier routing. Standard Construction Solid plain copper conductor, flame retardant Low Smoke Halogen Free insulation. Metallic barrier tape with copper earth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath.

38701502E

Technical Information Conductors: Voltage Rating: Resistance to Fire Alone: Resistance to Fire with Water: Resistance to Fire with Mechanical Shock: Approvals:

387E01504E cables

FS

Copper wire to BS 6360 or IEC 60228 300/500V IEC 60331: 3 hours at 750°C, BS 6387 Cat. C: 3 hours at 950°C BS 6387 Cat. W: 15 mins at 650°C, plus 15 mins with water spray BS 6387 Cat. Z: 15 mins at 950°C with mechanical shock BASEC, LPCB, BS7629: Part 1 BS 5839:1 2002 & EN 50200 Standard Grade

Part No.

Cores x mm²

O/D mm

Weight kg/km

38701002E 38701003E 38701004E 38701502E 38701503E 38701504E 38702502E 38702503E 38702504E

2 E 1.0 3 E 1.0 4 E 1.0 2 E 1.5 3 E 1.5 4 E 1.5 2 E 2.5 3 E 2.5 4 E 2.5

7.9 8.2 8.7 8.0 8.3 9.5 9.1 9.8 11.3

80 93 120 98 121 148 139 179 205

Gland

Clip

G251 G251 G251 G251 G251 G252 G252 G252 G252

RCH34 RCH34 RCH37 RCH37 RCH43 RCH47 RCH47 RCH51 RCH54

Standard pack size 100m or 500m. Other sizes are available to order. Also available in black and orange. Enhanced Construction

FS

Plain copper conductor, circuit integrity Low Smoke Halogen Free insulation, metallic barrier tape with copper earth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath. Standards:

cables

cables

FS

FS cables

BS 6387 BS 5839 - 1 BS EN 50200 BS 8434-2:2003 IEC 60332-3

C, W & Z 2002 Enhanced Grade Classification PH 120 120min duration Parts 1 & 3

Part No.

Cores x mm²

O/D mm

Weight kg/km

Part No.

387E01002E

2 E 1.0

7.9

80

387E01504E

387E01003E

3 E 1.0

8.2

93

387E02502E

387E01004E

4 E 1.0

8.7

120

387E01502E

2 E 1.5

8.0

387E01503E

3 E 1.5

8.3

O/D mm

Weight kg/km

4 E 1.5

9.5

148

2 E 2.5

9.1

139

387E02503E

3 E 2.5

9.8

179

98

387E02504E

4 E 2.5

11.8

205

121

387E04002E

2 E 4.0

12.1

269

www.fscables.com

Cores x mm²

sales@fscables.com


55

Firetuf Data & Coaxial FIRE & SECURITY Firetuf Data & Coaxial

Firetuf Data is a group of high performance fire survival data cables manufactured by Draka and designed to carry on functioning even in the event of a fire. This allows safe monitoring of evacuation routes without putting lives at risk. The twisted pair cables provide high data transmission rates and have been developed to mimic Cat-5 cabling as closely as possible. Increasingly popular with system integrators for BMS applications, the cables can be terminated using traditional LAN Insulation Displacement Connectors (IDC) making them ideal for use in horizontal backbone wiring systems in offices and public buildings. Where video is carried the coax performs in a similar way to RG59 which is widely used in the CCTV sector. This allows continued monitoring of fire exits and evacuation routes in the event of a fire. BNC connectors part no. YFTCBC1# are available to suit Firetuf Coax. Where people and property come first the Draka Firetuf Data cable range provides the ideal solution. Technical Information Design:

Generally to ISO/IEC 11801:95, EN 50173 95 and EN 50288-2-1. Suitable for standard insulation displacement connector L.A.N. sockets. RS-485 10Mb/s

Flame Retardant: Smoke Emission: Halogen Emission: Fire Resistant:

IEC 60332-1-2, EN 60332-1-2, IEC 60332-3-24C, EN 60332-3-24C, BS 4066 part 3 IEC 61034-2, EN61034-2, BS EN 50268-2 IEC 60754-1, EN 50267-2-1, IEC 61034-2, EN 50267-2-2, LU 1-085 A2 - toxic fume emissions BS 5839 Clause 26.2E > 2hrs @ 950°C BS 6387 > 3hrs @ 950°C IEC 60331-23 > 3hrs @ 750°C BS EN 50200 > 3hrs @ 950°C BS EN 50200:2000 BS 8438-2:2003 BS 8438-2 Class PH120 (120 minutes) BS 5839-1 2002 +A2 2008

387FTD403

London Underground Standard: LU 1-085-A2 fire safety performance of materials. Approved for use below ground without restriction. Firetuf Data Construction

Draka Part No.

Type

FS

Screen

Sheath

Weight kg/km

O/D mm

6.8

387FTD103

910234 1 Pair 0.63mm [22(1)AWG]

Foil & braid

LSHF Red

48

387FTD203

910244 2 Pair 0.63mm [22(1)AWG]

Foil & braid

LSHF Red

97

387FTD403

910245 4 Pair 0.63mm [22(1)AWG]

Foil & braid

LSHF Red

122

Firetuf Coax Construction

FS

cables

FSC Part No.

cables

22(1)AWG solid plain copper conductor, PE/silicone rubber composite insulation, cores twisted into pairs, pairs laid up, woven glass tape, aluminium screen in contact with stranded tinned copper drain wire, tinned copper wire braid, Low Smoke Halogen Free sheath - red. Colour code : Chart 5 (Western Electric)

387FTD5903

8.1

FS

10.4

cables

FS cables

1/0.65mm solid plain copper conductor, PE/silicone rubber composite dielectric, woven glass tape, two plain copper wire braids, Low Smoke Halogen Free sheath – red Draka Part No.

Type

Screen

Sheath

Weight kg/km

O/D mm

387FTD5903 YFTCBC1# YTC10

660096 -

75Ohm Coax 1/0.65mm BNC Connector BNC Crimp tool

Double braid -

LSHF Red -

110 -

9.1 -

cables

FS

FS

cables

FSC Part No.

Due to the unique size of Firetuf Coax special BNC connectors have been designed as standard types do not fit.

Tel: 01727 840 841

Fax : 01727 840 842

FS

cables

FS cables


56

FIRE & SECURITY Access Control Access Control N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Specifically designed for proprietary access control systems, these cables are widely used in public buildings including hospitals, government and local authority offices as well as commercial and retail organisations where security and safety are important.

3993P9CHP The Low Smoke Halogen Free versions ensure minimum risk in the event of fire to both property and personnel.

Composite Access Control - Purple Pipe 3993P9CHP Construction Pair 1:

1 twisted pair 20(7)AWG tinned copper strands, foam PE insulation, 20(7)AWG tinned copper drain wire, aluminium/polyester foil. Colour code: Black/green.

Pairs 2 & 3: 2 twisted pairs 22(7)AWG tinned copper strands, foam PE insulation, 22(7)AWG tinned copper drain wire, each individual pair aluminium/polyester foil screened. Pair colour code: Black/red & black/white. Cores:

9 single cores 22(7)AWG tinned copper wire strands, solid polypropylene insulation. Colour code: Black, white, red, green, brown, blue, orange, yellow, purple. Overall Screen: aluminium/polyester foil, 22(7)AWG tinned copper drain wire.

Sheath:

Low Smoke Halogen Free, purple.

Part No.

3993P9CHP

Alt. to Belden

No. of Pairs

AWG

Screen type

Weight kg/km

O/D mm

-

-

-

-

114

9.1

Alt. to Belden

No. of Pairs

AWG

Access Control

2202PIFR

cables

FS

FS

Part No.

Screen type

Weight kg/km

O/D mm

Protocol

2202PIFRL

8723

2

22

Individual foils

32

4.2

Traditional security

2202PIFRH

8723NH

2

22

Individual foils

32

4.2

Traditional security

2203PIFRL

8777

3

22

Individual foils

32

7.0

Traditional security

2203PIFRH

8777NH

3

22

Individual foils

32

7.0

Traditional security

2402POHPL

9842

2

24

O/A foil & braid

95

8.6

RS-485

2402POHPH 9842NH

2

24

O/A foil & braid

95

8.6

RS-485

2802PODGH 8132NH

2

28

O/A foil & braid

45

5.6

RS-485

2803PODGH 8133NH

3

28

O/A foil & braid

52

6.8

RS-485

cables

cables

FS

FS cables

Access control and door release cables are also available from stock in PVC versions either in standard pack sizes or cut to length from bulk drums.

Low Smoke Halogen Free

www.fscables.com

sales@fscables.com


57

Composite Coaxial & Door Entry FIRE & SECURITY Composite Coaxial & Door Entry To meet the increasing demands for camera cables containing a coax with power and control cores for Pan, Tilt, Zoom (PTZ) or audio we are now stocking at a variety of options. These can either be within one circular jacket for easy glanding or in a shotgun style with a web between the individual elements for branching off at termination points.

3900592/2

Designed to meet the need of the installer of proprietary door entry systems, door entry cables cover video, voice and door release. Stocked on bulk drums, cutting to length is offered to reduce your wastage and cut costs. Armoured and Duct grade versions are also available. Composite Coaxial Part No.

Coax

Power Cores

Signal Cores

Construction

O/D mm

Colour

3900592/2

RG59 B/U

2 x 1.5mm²

2 x 0.22mm²

Circular

10.8

Black

3900592/2D

RG59 B/U

2 x 1.5mm²

2 x 0.22mm²

Circular Duct

13.4

Black

3900592/2H

Black

RG59 B/U

2 x 1.5mm²

2 x 0.22mm²

Circular LSHF

10.8

390059/2

RG59

2 x 0.75mm²

-

Shotgun

12.7 x 6.2

Black

390059/2D

RG59

2 x 0.75mm²

-

Circular Duct

10.3

Black

Shotgun

12.2 x 6.2

Black

Shotgun LSHF 12.2 x 6.2

Black

390059-Shotgun 2 x RG59

-

-

390059H-Shotgun 2 x RG59

-

-

2 x 0.75mm²

-

391070/2

URM70

Shotgun

10.2 x 5.8

White

Door Entry Part No.

Coax

Power Cores

Signal Cores

Construction

O/D mm

Colour

DE12C

7/0.15mm 75 Ω 1 x 1.5mm² + 6 x 1mm²

5 x 0.5mm²

PVC

12.5

Grey

DE5C

7/0.15mm 75 Ω

3 x 0.5mm²

PVC

9.2

White

2 x 1mm²

DE12C

Other constructions are available on short lead-times please call us with your specific requirements.

FS

Alt. to Belden

No. of Pairs

AWG

Screen type

Weight kg/km

O/D mm

Protocol

1601PUYL

8471

1

16

Unscreened

56

7.0

Echelon

1601PUYH

8471NH

1

16

Unscreened

56

7.0

Echelon

FS

cables

FS

FS

FS

FS

FS

Duct Grade

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Low Smoke Halogen Free

FS

cables

Part No.

cables

Bus Wiring & Door Release

cables


58

FIRE & SECURITY Alarm Cables

Alarm Cables Designed for inter-connecting sensors and control panels, alarm cables are widely used within the security industry. Manufactured in white or black as standard, although other colours can be easily and quickly produced for quantities as low as 300m, for example to identify a circuit or blend with a colour scheme. Cables held in stock include standard PVC, Low Smoke Halogen Free, screened and duct grade versions. Technical Information Temperature Rating: Conductor Size:

Max Working Voltage: 50V Max Current: 1 amp per core

0째C to +70째C 0.22mm2 (24AWG)

Construction

39800208W

PVC:

Tinned copper wire strands, PVC insulation, PVC sheath

LSHF:

Tinned copper wire strands, Low Smoke Halogen Free insulation, Low Smoke Halogen Free sheath (with or without aluminium foil screen)

Screened: Tinned copper wire strands, PVC insulation, aluminium foil screen with tinned copper drain wire, PVC sheath Duct:

Tinned copper wire strands, PVC insulation, PVC inner sheath, black LDPE outer sheath

Unscreened Alarm Part No.

Screened Alarm

Cores

Weight kg/km

O/D mm

cables

cables

cables

FS

18

3.4

39900204W

4

24

3.7

39800206W

6

25

4.0

39900206W

6

28

4.3

39800208W

8

30

4.3

39900208W

8

34

4.6

39800212W

12

37

5.5

39900212W

12

47

6.2

Part No.

Cores

Weight kg/km

O/D mm

Weight kg/km

O/D mm

Part No.

Cores

LSHF Foil Screened Alarm Cable

39800204WH

4

18

3.4

39900204WH

4

24

3.7

39800206WH

6

25

4.0

39900206WH

6

28

4.3

39800208WH

8

30

4.3

39900208WH

8

34

4.6

39800212WH

12

42

5.7

Cores

Weight kg/km

O/D mm

Cores

Weight kg/km

O/D mm

Part No.

Duct Grade Screened Alarm Cable

Duct Grade Unscreened Alarm Cable

39200206D

6

52

6.8

39400206D

6

53

7.1

39200208D

8

56

7.1

39400208D

8

58

7.6

39200212D

12

68

8.4

39400212D

12

72

9.0

Core Colour Code 4-core: Red, blue, yellow, black 6-core: Red, blue, yellow, black, white, green 8-core: Red, blue, yellow, black, white, green, orange*, brown 12-core: Red, blue, yellow, black, white, green, orange, brown, grey, pink, violet, turquoise *On duct grade cables core 7 is violet. Brown or black PVC alarm cable also available. Standard packing 100m, 200m & 500m spools.

FS cables

O/D mm

4

Part No.

FS

Weight kg/km

39800204W

LSHF Unscreened Alarm Cable

FS

Cores

PVC Foil Screened Alarm Cable

PVC Unscreened Alarm Cable

39900208WH

Part No.

Low Smoke Halogen Free

Duct Grade

www.fscables.com

sales@fscables.com


59

Outdoor Control FIRE & SECURITY Outdoor Control The FSC range of duct grade YY cable is suitable to be either run through ducts or clipped to buildings or other exposed areas when an armoured cable is not required. The cables are rated to 0.6/1kV and have XLPE insulation, a PVC bedding and a UV stable black polyethylene sheath which also gives additional mechanical strength and water resistance. The colour code is the conventional brown, blue, green/yellow (on three core) for simple wiring. Despite their toughness they remain remarkably flexible.

10001504D

The cable is stocked on bulk drums and can be cut to length to reduce your wastage and save time. If you don’t see the size you require please call us because we offer a cable over-sheathing service. If these cables require added protection we can also armour them with MOQs as low as a hundred metres. Please see page 152-153 for more details or call us with your specific requirements. Despite their toughness they remain remarkably flexible. They can also be used as an alternative to the old Delta Hi-Tuf cables.

Construction

Technical Information

Plain copper wire conductors to IEC 60228 class 5, XLPE colour coded insulation, bedding compound of PVC, UV resistant polyethylene sheath.

Voltage Rating: Conductor Stranding: Temperature Rating: Bending Radius:

0.6/1kV Stranded. IEC 60228 class 5 -30°c to +90°c 10 x overall diameter

For other cables suitable for outdoor applications please see page 60-61 for more details

Part No.

Cores x mm2

Colour Code

Weight kg/km

O/D mm

9.1

2 x 1.0

Blue, Brown

78

10001003D

3 x 1.0

Blue, Brown, Green/Yellow

98

9.2

10001004D

4 x 1.0

Brown, Black, Grey, Green/Yellow

121

9.6

10001005D

5 x 1.0

Blue, Brown, Black, Grey, Green/Yellow

149

10.7

10001502D

2 x 1.5

Blue, Brown

105

9.2

10001503D

3 x 1.5

Blue, Brown, Green/Yellow

156

10.5

10001504D

4 x 1.5

Brown, Black, Grey, Green/Yellow

181

11.4

10001505D

5 x 1.5

Blue, Brown, Black, Grey, Green/Yellow

201

12.3

2 x 2.5

Blue, Brown

154

11.0

3 x 2.5

Blue, Brown, Green/Yellow

183

11.0

10002504D

4 x 2.5

Brown, Black, Grey, Green/Yellow

241

13.1

10002505D

5 x 2.5

Blue, Brown, Black, Grey, Green/Yellow

304

14.2

cables

FS

10002502D 10002503D

FS

cables

FS

FS

FS

FS

FS

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Duct Grade

FS

cables

10001002D

cables


60

FIRE & SECURITY Outdoor Data & Coaxial N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC Outdoor Data & Coaxial 60331)

2403POFYD

With the increased use of data and signal cables in security, BMS, access control and monitoring applications the need for suitable cables to run outside or through ducts has grown. FS Cables offer an over-sheathing service for any stock product for quantities as low as 100m. The products listed below are all stock items and have heavy additional black UV resistant polyethylene sheaths similar to those used on external telephone cables you see strung between poles or run though ducts.

Part No.

Alternative to Belden

Number of Pairs & AWG

Weight kg/km

O/D mm

Colour

Outdoor Data Cables 1801POFPD

8760

1 x 2 x 18

48

7.6

Black

2202PIFRD

8723

2 x 2 x 22

50

6.2

Black

2203PIFRD

8777

3 x 2 x 22

96

8.6

Black

2401POFYD

9501

1 x 2 x 24

44

6.2

Black

2403POFYD

9503

3 x 2 x 24

66

8.1

Black

2404POFYD

9504

4 x 2 x 24

72

8.9

Black

2406POFYD

9506

6 x 2 x 24

93

9.6

Black

2402PIFFD

9729

2 x 2 x 24

79

10.2

Black

2402POHPD

9842

2 x 2 x 24

118

10.6

Black

Part No.

Description

Number of Pairs & AWG

Weight kg/km

O/D mm

Colour

Exterior Grade Structured Wiring C5ED

C5ED

Cat 5E UTP Duct Grade

4 x 2 x 24

67

8.6

Black

C5EFD

Cat 5E FTP Duct Grade

4 x 2 x 24

68

8.8

Black

C525D

Cat 5 UTP Duct Grade

25 x 2 x 24

278

17.0

Black

C6D

Cat 6 UTP Duct Grade

4 x 2 x 23

86

9.9

Black

C6FD

Cat 6 FTP Duct Grade

4 x 2 x 23

105

10.2

Black

Part No. cables

FS

FS cables

Description

Weight kg/km

O/D mm

Colour

Black

Outdoor Coaxial Cables 390011D

RG11 A/U Duct Grade

194

12.1

390058D

RG58 C/U Duct Grade

59

6.5

Black

390059D

RG59 B/U Duct Grade

70

8.0

Black

391070D

URM 70 Duct Grade

67

7.8

Black

392100D

TV 100 Duct Grade

30

7.0

Black

392125D

TV 125 Duct Grade

52

9.5

Black

392167D

TV 167 Duct Grade

110

11.7

Black

cables

FS

FS cables

Duct Grade

www.fscables.com

sales@fscables.com


61

Armoured Data & Coaxial FIRE & SECURITY N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC Armoured Data & Coaxial 60331) Where data or signal cables may be exposed to mechanical damage an additional protection of galvanised steel wire armour or SWA is ideal. Suitable for direct burial these cables are also popular in applications above ground where accidental or deliberate damage may occur.

390059A

CCTV installation in football stadiums, shopping centres and other public areas need to continue functioning despite the activities of trouble makers. Equally important may be data or security cabling in car parks, warehouses and factories where vehicle damage may severely compromise the operation of business.

Part No.

Alternative to Belden

Number of Pairs & AWG

Weight kg/km

O/D mm

Colour

2202PIFRA

8723

2 x 2 x 22AWG

200

10.0

Black

2203PIFRA

8777

3 x 2 x 22AWG

330

13.3

Black

2402POHPA

9842

2 x 2 x 24AWG

431

16.3

Black

2402PIFFA

9729

2 x 2 x 24AWG

387

15.4

Black

Part No.

Description

Number of Pairs & AWG

Weight kg/km

O/D mm

Colour

Armoured Structured Wiring C5EA

Cat 5E UTP

4 x 2 x 24AWG

259

12.6

C525A

Cat 5E UTP

25 x 2 x 24AWG

540

20.2

Black

C5EFA

Cat 5E FTP

4 x 2 x 24AWG

271

13.0

Black

C6A

Cat 6 UTP

4 x 2 x 23AWG

354

14.3

Black

C6FA

Cat 6 FTP

4 x 2 x 23AWG

386

15.1

Black

Part No.

Description

Weight kg/km

O/D mm

Black

Colour

Armoured Coaxial Cables 390011A

RG11 A/U

367

14.4

Black

390059A

RG59 B/U

235

10.5

Black

390062A

RG62 A/U

214

10.3

Black

FS

cables

FS

FS

FS

FS

FS

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

SWA

cables

FS

cables

FS

cables


62

LONDON UNDERGROUND LU Approved Cables

London Underground Approved Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Designed to meet London Underground (LU) specification for fire performance this collection of cables is also popular on overground railways, other transport systems and other commercial applications where fire and smoke propagation are critical factors. Applications range from CCTV and radio communications to alarm and emergency evacuation circuits. Coaxial Cables Construction Solid plain copper conductor, foamed PE dielectric, copper foil screen, plain copper wire braid, LSHF inner sheath.

390H124HLU

Part No.

390H124HLU

London Underground Standard E4156.1-A3 & E4156.2-A4 Section 12 Approved LSHF Sheath Material to HD 624

Description

Imp. Ohms

Central Cond.

H124 LSHF UV Resistant

75

1/1.00

Dielectric

Sheath Weight kg/km

FPE

O/D mm

LSHF

53

7.0

Triaxial Cables Construction

London Underground Standard

Solid plain copper conductor, foamed PE dielectric, copper foil screen, plain copper wire braid, LSHF inner sheath.

E4156.1-A3 & E4156.2-A4 Section 12 Approved LSHF Sheath Material to HD 624

Part No.

390H124HTLU

Description

Imp. Ohms

Central Cond.

Dielectric

Sheath

Weight kg/km

O/D mm

H124 LSHF UV Resistant

75

1/1.00

FPE

LSHF

99

8.8

Cat 5E FTP LSZH Construction 24(1)AWG solid plain copper conductor, polyolefin insulation, tinned copper drain wire in contact with overall aluminium foil screen, flame retardant LSHF grey sheath. This cable meets the London Underground Code of Practice for Fire Safety of Materials used in the Underground. Part No.

Description

Weight kg/km

O/D mm

Packed

Colour

Cat 5E FTP LSHF

40

6.5

On reels

Grey

64904002 C5EFHRLU cables

FS

Single Core LSHF Construction Class 2 plain copper conductor, single or double layer of LSHF insulation.

FS cables

cables

FS

Part No.

649010xx 649015xx 649025xx 649040xx 649060xx 649100xx 649160xx 649250xx 649350xx

Technical Information Temperature Rating: 90°C Voltage Rating: 450/750V AC Fire Test & Smoke Emission: 1.0-10mm² to LUL 1-085 16 – 35mm² to LUL 2-01001-002 Toxicity: To LUL 1-085

Size mm2

1.0 1.5 2.5 4.0 6.0 10 16 25 35

Insulation Layer

Weight kg/km

O/D mm

Double Double Double Double Double Double Single Single Single

35 40 55 75 100 150 190 300 390

4.7 2.0 5.3 6.0 6.6 7.8 7.6 9.6 10.8

*please see page 91 for colour chart

FS cables

www.fscables.com

sales@fscables.com


63

LU Approved Cables LONDON UNDERGROUND Fire Alarm Cable - Standard Construction

Standards

Solid plain copper conductor, silicone rubber, metallic barrier, tinned copper earth conductor, Low Smoke Halogen Free sheath.

BS5839-1:2002 Clause 26.2d standard BS EN 50200 PH30, PH 60 Annexe E. BS 6387 C, W & Z IEC 60331-2, IEC 60332-3, IEC 60332-1, BS EN 50265, BE EN50266, IEC 60754, BS EN 50267, IEC 61034, BS EN 50268

Cores x mm2

Part No.

Colour

Weight kg/km

387E01504FTER

O/D mm

38701502FTER

2 x 1.5

Red

100

7.7

38701502FTEW

2 x 1.5

White

100

7.7

38701504FTER

4 x 1.5

Red

145

9.2

38701504FTEW

4 x 1.5

White

145

9.2

38702502FTER

2 x 2.5

Red

150

8.9

38702502FTEW

2 x 2.5

White

150

8.9

38702504FTER

4 x 2.5

Red

220

10.9

38702504FTEW

4 x 2.5

White

220

10.9

Fire Alarm Cable - Enhanced Construction

Standards

Solid plain copper conductor, enhanced silicone rubber, glass tape, tinned copper earth conductor, metallic barrier, enhanced Low Smoke Halogen Free sheath.

BS5839-1:2002 Clause 26.2e enhanced BS8434-2:2003 BS EN 50200 PH120 BS 6387 C, W & Z IEC 60332-3, IEC 60332-1, BS EN 50265, BE EN50266, IEC 60754, BS EN 50267, IEC 61034, BS EN 50268

Cores x mm2

Part No.

O/D mm

Red White Red White Red White Red White

130 130 170 170 175 175 250 250

8.6 8.6 10.1 10.1 9.9 9.9 11.9 11.9

Firetuf Data & Coax

FS

FS

FS

FS

cables

For full technical details please see page 55 FSC Part No.

387FTD403

Type

Screen

Sheath

Weight kg/km

O/D mm

387FTD103

910234

Foil & Braid

LSHF red

48

6.8

387FTD203

910244

Foil & Braid

LSHF red

97

387FTD403 387FTD5903

910245 660096

1 Pair 0.63mm [22(1)AWG] 2 Pair 0.63mm [22(1)AWG] 4 Pair 0.63mm 75ohm coax 1/0.65mm

Foil & Braid Double braid

LSHF red LSHF red

122 110

Fax : 01727 840 842

8.1

cables

Tel: 01727 840 841

FS

cables

FS

cables

Draka Part No.

cables

2 x 1.5 2 x 1.5 4 x 1.5 4 x 1.5 2 x 2.5 2 x 2.5 4 x 2.5 4 x 2.5

Weight kg/km

cables

387E01502FTER 387E01502FTEW 387E01504FTER 387E01504FTEW 387E02502FTER 387E02502FTEW 387E02504FTER 387E02504FTEW

Colour

10.4 9.1

FS

cables

FS cables


64

TELEPHONE CW1308 PVC

CW1308 PVC Internal N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Manufactured to British Telecom Specification CW1308, this cable is used for internal connection of telephone systems and Fire resistant screenedequipment. power cables provide EMI screening and circuit integrity in the event of a fire. They are ideal for other communications applications such as fire pumps and ventilation systems in office blocks where electrical interference needs keeping to a minimumand during normal services be maintained for evacuation fire situation. cables meet Insulated sheathed in operation PVC, theseand cables offermust an extremely cost effective generalduring signalacable for fixed The installation. IEC 60331 and are fireisresistant for 3 hours at sizes 750°C. Standard sheath colour white although some are available in black or grey. cablesspecification to DIN 4102 telephone part 12 arecables also available request. AE30 fullSystem range integrity of European is also on available on short lead times, please call us with your requirements. Construction

Technical Information

Solid copper conductor, colour coded PVC insulation,

Conductor Diameter:

0.5mm

twisted in pairs, rip cord, PVC sheath.

Max. Conductor Resistance:

97.8 Ohm/km 12.4 Ohm/km

Earth 1.38mm

Max. Capacitance Unbalanced: 500pF/km

Part No.

30810E

cables

FS

FS cables

cables

FS

FS cables

Temperature Rating:

Working

Min. Bend Radius Fixed:

8 x cable diameter

0°C to +70°C

No. of Pairs

Weight kg/km

O/D mm

30802

2

21

4.5

30803

3

28

5.0

30804

4

34

5.8

30806

6

44

6.8

30810

10

67

8.3

30810E

10+E

85

8.6

30815

15

115

9.8

30820

20

150

10.7

30820E

20+E

183

12.0

30825

25

184

11.4

30825E

25+E

210

12.0

30830

30

226

12.2

30830E

30+E

262

12.9

30840E

40+E

371

15.0

30850E

50+E

427

17.0

30880E

80+E

610

20.2

308100E

100+E

708

27.0

308160E

160+E

1059

30.3

308200E

200+E

1393

33.1

Other pair combinations or larger numbers of pairs and alternative conductor sizes are available on request. Cables ending with E include a 1.38mm Earth core. Colour codes to BT Standards, see page 166-167.

www.fscables.com

sales@fscables.com


65

CW1308 LSHF TELEPHONE CW1308 LSHF Internal

When you need a LSHF internal telephone cable but don’t want to go to the expense of CW1600 this range is ideal. Manufactured generally in accordance with BT CW1308 specification both the insulation and sheath materials have been changed to ones that don’t emit poisonous halogens in the event of a fire. These cables are not to be confused with the cheaper, PVC insulated, modified PVC jacketed LSF versions that have appeared on the market in the last few years. Construction

Technical Information

Solid copper conductor, colour coded Low Smoke

Conductor Diameter:

0.5mm

Halogen Free insulation, twisted into pairs, rip cord,

Max. Conductor Resistance:

97.8 Ohm/km 12.4 Ohm/km

Low Smoke Halogen Free jacket, white. Earth core

Max. Capacitance Unbalanced: 500pF/km

in cables with 10 pairs or more.

Temperature Rating:

Working

Min. Bend Radius Fixed:

8 x cable diameter

Part No.

No. of Pairs

Weight kg/km

O/D mm

30802H

2

22

4.5

30803H

3

31

5.0

30804H

4

34

5.8

30806H

6

50

6.8

30810EH

10+E

102

8.6

30820EH

20+E

161

12.0

30850EH

50+E

352

17.0

308100EH

100+E

687

27.0

Earth 1.38mm

0°C to +70°C

30850EH

FS

cables

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

FS

cables

FS

cables


66

TELEPHONE CW1600 LSHF

CW1600 LSHF Limited Fire Hazard Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: XLPE/Cu/LSHF LSHF Power Cable – 0.6/1kV This cable is similar in design and application to CW1308 but with the addition of an aluminium foil screen and Low Smoke Halogen Free cores and sheath. Used for the internal wiring of buildings where the need to protect people and equipment from smoke and fumes is paramount. CW1600 has the added advantage of an aluminium/polyester foil screen and drain wire. A fire barrier tape is included on cable with more than 6 pairs. A rip cord is located directly under the jacket to make stripping the outer sheath easier. Construction

Technical Information

Solid copper conductor, colour coded Low Smoke Halogen Free

Conductor Diameter:

0.5mm

insulation. Twisted into pairs, screened with an aluminium /

Max. Conductor Resistance:

97.8 Ohm/km 12.4 Ohm/km

polyester tape in contact with solid copper drain wire, fire barrier

Max. Capacitance Unbalanced: 500pF/km

tape on cables with more than 6 pairs, Low Smoke Halogen Free

Temperature Rating:

Working

sheath.

Minimum Bending Radius:

8 x cable diameter

Oxygen Index:

35%

HCl Emissions to:

BT M234

Part No.

60010E

cables

FS

Earth 1.38mm

0°C to +70°C

No. of Pairs

Weight kg/km

O/D mm

60003

3

35

6.0

60004

4

39

6.4

60006

6

66

6.8

60010E

10+E

102

8.6

60020E

20+E

167

12.0

60040E

40+E

295

15.0

60050E

50+E

358

20.0

600100E

100+E

692

26.0

Cables ending with E include a 1.38mm Earth core. Colour codes to BT Standards, see page 166-167. All sizes are normally available from stock. Armoured versions can be produced to order for quantities as low as 100m.

FS cables

cables

FS

FS cables

www.fscables.com

sales@fscables.com


67

Functional Earth & Drop Wire TELEPHONE CW1044 Functional Earth CW1044 is primarily intended to provide a connection to earth for internal telephone systems. It features a single core plain annealed copper conductor which is solid in 1.5mm2 and stranded in all other sizes. 16mm2 and above is stocked in Low Smoke Halogen Free versions only. The insulation is cream with black printing ‘Telecom Functional Earth’.

Part No.

Size mm²

Stranding

Weight kg/km

Nominal O/D mm

044015

1.5

1/1.38

24

3.3

044025

2.5

7/0.67

38

3.9

04404

4.0

7/0.85

57

4.6

04406

6.0

7/1.04

87

5.4

04410

10

7/1.35

110

6.1

04416H

16

7/1.70

172

7.1

04425H

25

7/2.14

285

8.9

04435H

35

7/2.52

380

10.1

04450H

50

19/1.78

510

11.8

04416H

CW1411 & CW1417 BT Drop Wire

37804

The FSC range of self supporting aerial cables is designed for use in local area networks to link between pole and building or two buildings. The high tensile steel strainer wires are incorporated within the cable. A black polyethylene sheath, which is UV stable offers excellent weather resistance. 2 pair Ref: CW1411 4 pair Ref: CW1417 No. of Pairs

37802

10B

2

37804

14 (55m)

4

Conductor Dia. mm

FS

FS

FS

cables

FS

FS

FS

FS

FS

Weight kg/km

Nominal O/D mm

0.5

32

5.3

0.5

35

5.6

Standard packing on Drop Wire is 350m reels.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Low Smoke Halogen Free

cables

BT Ref

cables

Part No.

cables


68

TELEPHONE CW1128

CW1128 External CW1128 external telephone cables are suitable for installation outdoors where an armoured cable is not necessary. They offer a lightweight, compact, tough solution for cables that will have to endure a variety of weather conditions, from rain and snow to bright sunlight. CW1128 is ideal for clipping around the outside of buildings or running through ducting. The outer sheath is made from tough, durable polyethylene which is also UV and sunlight resistant. The pairs are bedded in petroleum jelly to protect against the ingress of moisture.

Construction

Technical Information

Solid plain copper conductor, colour coded polyethylene

Conductor Diameter:

0.5mm

0.9mm

insulation, petroleum jelly filled, separator tape and a black

Max. Conductor Resistance:

91 Ohm/km

28 Ohm/km

polyethylene sheath.

Insulation Resistance:

1500 Mohm/km 1500 Mohm/km

Part No.

Capacitance Unbalanced: >3pair 275pF/m

275pF/m

Colour Code: see page 167

To CW1128

To CW1128

No. of Pairs

Conductor Dia. mm

Weight kg/km

O/D mm

12800502

2 (Quad)

0.5

50

5.9

12800503

3

0.5

58

6.6

12800505

5

0.5

76

8.0

12800510

10

0.5

113

9.5

12800520

20

0.5

184

12.0

12800530

30

0.5

249

13.0

12800550

50

0.5

381

16.5

128005100

100

0.5

710

22.0

Part No.

No. of Pairs

Conductor Dia. mm

Weight kg/km

O/D mm

12800520 Solid 0.5mm

cables

FS

FS cables

Solid 0.9mm 12800901Q

2 (Quad)

0.9

72

7.2

12800905

5

0.9

160

11.5

12800910

10

0.9

261

14.0

12800920

20

0.9

452

18.0

12800950

50

0.9

1076

26.5

128009100

100

0.9

2033

36.0

Aluminium screened/moisture barrier versions of this cable are also available in the style of CW1179 with some sizes from stock. Please call to check availability. cables

FS

FS cables

Duct Grade

www.fscables.com

sales@fscables.com


69

CW1128/1198 TELEPHONE CW1128/1198 Armoured

CW1128/1198 type telephone cables are used for external connection of telephone systems and other communications equipment where the added protection of steel wire armouring is needed. This cable is ideally suited for direct burial. The outer sheath is made from tough, durable polyethylene or external grade PVC which is UV and sunlight resistant. The cores are bedded in petroleum jelly to protect against the ingress of moisture. Construction

Technical Information

Solid plain copper conductor, colour coded

Conductor Diameter:

0.5mm

0.9mm

polyethylene insulation, petroleum jelly filled,

Max. Conductor Resistance:

91 Ohm/km

28 Ohm/km

separator tape, polyethylene bedding, galvanised

Insulation Resistance:

1500 Mohm/km 1500 Mohm/km

steel wire armour and a black or grey polyethylene or

Capacitance Unbalanced: >3pair 275pF/m

275pF/m

external grade PVC sheath.

Colour Code: see page 167

To CW1128

Part No.

No. of Pairs

Conductor Dia. mm

Weight kg/km

To CW1128

O/D mm

19800520

Solid 0.5mm 19800501Q

2 (Quad)

0.5

187

19800505

5

0.5

218

10.1 11.0

19800510

10

0.5

285

12.2

19800520

20

0.5

378

14.5

19800530

30

0.5

621

16.2

19800550

50

0.5

896

20.4

198005100

100

0.5

1368

26.2

Part No.

No. of Pairs

Conductor Dia. mm

Weight kg/km

O/D mm

2 (Quad)

0.9

320

12.8

19800905

5

0.9

496

13.9

19800910

10

0.9

738

17.4

19800920

20

0.9

1257

23.6

19800950

50

0.9

2310

32.3

198009100

100

0.9

3487

40.6 cables

FS

FS

FS

FS

FS

FS

FS

FS

cables

19800901Q

cables

Solid 0.9mm

cables

Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please call to check availability.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

SWA

cables


70

TELEPHONE J-Y(St)Y: PVC Screened

J-Y(St)Y: PVC Screened Telephone Cable Originally developed for use within offices and factories J-Y(St)Y meets the needs of the German telecom installers and increasingly their European counterparts. The larger conductor sizes result in lower losses than the traditional British CW1308. The foil screen also reduces interference either radiating from or picked up by the cable. Other applications include security, agriculture, intercom and bus systems.

Construction

Technical Information

Solid copper wire conductors to IEC 60228 class 1, PVC

Voltage Rating:

300V

insulation, overall foil screen in contact with solid copper

Conductor Stranding:

Solid IEC 60228 class 1

drain wire, PVC sheath – grey.

Temperature Rating:

Static -30°C to +70°C

Core Identification

Bending Radius:

Fixed 7.5 x overall diameter

Flame Retardant:

VDE 0472 test B,

Flexing -5°C to +50°C

Colour code according to DIN VDE 0815.

IEC 60332-1-2, EN 50265-2-1 Manufactured To:

VDE 0815

J-Y(St)Y can be also be supplied with a red outer jacket for identifying fire alarm systems that do not need to meet British building regulations, please put ‘03’ at the end of the part number to specify this cable. Also available unscreened as J-YY

31000602

cables

FS

FS cables

cables

FS

FS cables

Part No.

Pairs x mm

Weight kg/km

O/D mm

Part No.

31000602

2 x 2 x 0.6

45

5.0

31000802

31000603

3 x 2 x 0.6

55

6.4

31000803

31000604

4 x 2 x 0.6

65

6.6

31000605

5 x 2 x 0.6

75

31000606

6 x 2 x 0.6

85

Pairs x mm

Weight kg/km

O/D mm

2 x 2 x 0.8

65

7.0

3 x 2 x 0.8

85

8.6

31000804

4 x 2 x 0.8

105

9.1

7.3

31000805

5 x 2 x 0.8

125

9.6

7.5

31000806

6 x 2 x 0.8

150

11.2

31000608

8 x 2 x 0.6

95

8.0

31000808

8 x 2 x 0.8

180

11.7

31000610

10 x 2 x 0.6

115

10.1

31000810

10 x 2 x 0.8

225

13.3

31000612

12 x 2 x 0.6

130

10.4

31000812

12 x 2 x 0.8

255

14.0

31000616

16 x 2 x 0.6

155

11.0

31000816

16 x 2 x 0.8

320

16.1

31000620

20 x 2 x 0.6

200

12.1

31000820

20 x 2 x 0.8

385

17.0

31000624

24 x 2 x 0.6

225

13.2

31000824

24 x 2 x 0.8

470

19.1

31000630

30 x 2 x 0.6

285

14.0

31000830

30 x 2 x 0.8

570

20.9

31000640

40 x 2 x 0.6

355

15.1

31000840

40 x 2 x 0.8

715

23.2

31000650

50 x 2 x 0.6

440

17.3

31000850

50 x 2 x 0.8

900

26.2

31000660

60 x 2 x 0.6

510

19.2

31000860

60 x 2 x 0.8

1050

28.1

31000680

80 x 2 x 0.6

650

21.3

31000880

80 x 2 x 0.8

1450

31.6

310006100

100 x 2 x 0.6

850

24.0

310008100

100 x 2 x 0.8

1800

33.0

Larger pair counts and screened or moisture barrier versions to CW1179 are also available. Please call to check availability.

www.fscables.com

sales@fscables.com


71

J-H(St)H: LSHF Screened TELEPHONE J-H(St)H: LSHF Screened Telephone Cable

J-H(St)H was originally developed in Germany for internal wiring in sensitive areas. A number of things set this apart from the UK internal telephone cable CW1308. The major differences are it is LSHF throughout, screened, comes in 0.6mm or 0.8mm conductor size and has a completely different colour code. It is now finding popularity for wiring everything from intercom and nurse call systems right through to sophisticated security installations where the benefits of a screened LSHF low resistance cable make it an ideal choice.

Construction

Technical Information

Plain copper wire conductors to IEC 60228 class 1, LSHF

Voltage Rating:

300V

insulation, overall foil screen in contact with plain copper

Conductor Stranding:

Solid IEC 60228 class 1

drain wire, LSHF sheath – grey.

Temperature Rating:

Static -30°C to +70°C

Core Identification

Bending Radius:

Fixed 7.5 x overall diameter

Flame Retardant:

IEC 60332-3-24 Cat C

Halogen Emissions:

IEC 60754-2, BS EN 50267

Smoke Emissions:

IEC 61034-2, BS EN 50268

Flexing -5°C to +50°C

Colour code according to DIN VDE 0815.

J-H(St)H can be also be supplied with a red outer jacket for identifying permitted fire alarm systems, please put ‘03’ at the end of the part number to specify this cable.

Part No.

Pairs x mm

Weight kg/km

O/D mm

Part No.

Pairs x mm

Weight kg/km

O/D mm

31000602H

2 x 2 x 0.6

45

5.0

31000802H

2 x 2 x 0.8

65

7.0

31000603H

3 x 2 x 0.6

55

6.4

31000803H

3 x 2 x 0.8

85

8.6

31000604H

4 x 2 x 0.6

65

6.6

31000804H

4 x 2 x 0.8

105

9.1

31000605H

5 x 2 x 0.6

75

7.3

31000805H

5 x 2 x 0.8

125

9.6

31000606H

6 x 2 x 0.6

85

7.5

31000806H

6 x 2 x 0.8

150

11.2

31000602H

95

8.0

31000808H

8 x 2 x 0.8

180

11.7

10 x 2 x 0.6

115

10.1

31000810H

10 x 2 x 0.8

225

13.3

31000612H

12 x 2 x 0.6

130

10.4

31000812H

12 x 2 x 0.8

255

31000616H

16 x 2 x 0.6

155

11.0

31000816H

16 x 2 x 0.8

320

31000620H

20 x 2 x 0.6

200

12.1

31000820H

20 x 2 x 0.8

385

FS

31000624H

24 x 2 x 0.6

225

13.2

31000824H

24 x 2 x 0.8

470

19.1

31000630H

30 x 2 x 0.6

285

14.0

31000830H

30 x 2 x 0.8

570

20.9

31000640H

40 x 2 x 0.6

355

15.1

31000840H

40 x 2 x 0.8

715

31000650H

50 x 2 x 0.6

440

17.3

31000850H

50 x 2 x 0.8

900

31000660H

60 x 2 x 0.6

510

19.2

31000860H

60 x 2 x 0.8

1050

28.1

31000680H

80 x 2 x 0.6

650

21.3

31000880H

80 x 2 x 0.8

1450

31.6

310006100H 100 x 2 x 0.6

850

24.0

310008100H 100 x 2 x 0.8

1800

33.0

14.0 16.1 17.0

FS 23.2

26.2 cables

cables

FS

FS

FS

cables

cables

Fax : 01727 840 842

FS

FS

cables

Tel: 01727 840 841

FS

cables

8 x 2 x 0.6

31000610H

cables

31000608H

cables


72

SIGNAL & CONTROL YY PVC

YY PVC Multicore XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable ideal for use on portable or movable equipment or where flexibility will make installation considerably easier. A 600/1000V grade is now available in sizes above 0.75mm2 as are American UL listed versions. Where resistance to water or many oils is required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times.

Construction

Technical Information

Fine copper wire strands to IEC 60228 class 5 or class 6

Voltage Rating: Temperature Rating:

300/500V Test 3000V Static -20°C to +80°C Flexing -5°C to +70°C Minimum Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter

depending on cross section. PVC insulation with either number or colour coding. A green/yellow earth core is normally included in cables with more than 2 cores in 0.5mm2 and above. Cores twisted together, grey PVC sheath.

Part No.

10001507

Cores x mm²

Weight kg/km

YY Multicore Cable Number Coded 10000502 2 x 0.5 33 10000503 3 x 0.5 43 10000504 4 x 0.5 46 10000505 5 x 0.5 53 10000507 7 x 0.5 75 10000512 12 x 0.5 113 10000518 18 x 0.5 167 10000521 21 x 0.5 194 10000540 40 x 0.5 347

Current Rating:

O/D mm

4.9 5.2 5.7 6.4 6.6 8.9 10.7 11.7 15.5

Part No.

Cores x mm²

Weight kg/km

O/D mm

10001018 10001021 10001025 10001034 10001041 10001042 10001050 10001080

18 x 1.0 21 x 1.0 25 x 1.0 34 x 1.0 41 x 1.0 42 x 1.0 50 x 1.0 80 x 1.0

266 313 356 469 588 601 691 1099

12.4 14.2 14.7 16.6 18.3 18.5 19.9 24.6

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 10 x 1.5 12 x 1.5 14 x 1.5 18 x 1.5 21 x 1.5 25 x 1.5 32 x 1.5 34 x 1.5 42 x 1.5 50 x 1.5 61 x 1.5 65 x 1.5

64 80 99 112 150 212 250 289 362 426 515 634 671 836 973 1181 1359

6.2 6.6 7.3 7.9 8.9 11.2 11.7 12.8 13.9 15.5 17.2 18.7 19.3 20.4 22.6 25.2 26.8

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5

96 125 152 173 238 384 559

7.6 8.0 8.8 9.8 11.9 14.5 17.4

FS cables

10000702 10000703 10000704 10000705 10000707 10000708 10000710 10000712 10000718 10000721 10000725 10000734 10000741 10000742 10000750 10000761

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 8 x 0.75 10 x 0.75 12 x 0.75 18 x 0.75 21 x 0.75 25 x 0.75 34 x 0.75 41 x 0.75 42 x 0.75 50 x 0.75 61 x 0.75

41 54 58 69 97 109 133 151 216 263 296 392 466 496 585 693

5.2 5.7 6.1 6.7 7.2 8.6 9.3 9.9 11.5 13.8 14.1 15.9 16.9 17.6 19.3 20.9

10001502 10001503 10001504 10001505 10001507 10001510 10001512 10001514 10001518 10001521 10001525 10001532 10001534 10001542 10001550 10001561 10001565

FS

10001002 10001003 10001004 10001005 10001007 10001010 10001012

2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 10 x 1.0 12 x 1.0

50 60 63 81 126 157 183

5.5 5.9 6.6 7.1 7.6 9.9 10.5

10002502 10002503 10002504 10002505 10002507 10002512 10002518

cables

FS

cables

FS cables

Refer to IEE Regs Table 4F3A&B

Other core counts and sizes are available please ask for more details. Overall diameters (O/D) are approximate and for guidance only and will vary from one manufacture to another. If the O/D is critical please check at time of order and we will measure it.

www.fscables.com

sales@fscables.com


73

YY PVC SIGNAL & CONTROL Cores x mm²

Weight kg/km

O/D mm

Part No.

10001502C 10001503C 10001504E 10001505E 10001507C 10001512C

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5

64 80 99 112 150 250

6.2 6.6 7.3 7.9 8.9 11.7

10002502C 10002503C 10002504E 10002505E 10002507C 10002512C

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5

96 125 152 173 238 384

7.6 8.0 8.8 9.8 11.9 14.5

10004003C 10004004E 10004005E 10004007C

3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0

260 302 359 482

11.9 12.6 13.8 15.5

10006003C 10006004E 10006005E 10006007C

3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0

319 396 493 660

12.8 13.7 15.8 17.5

10010003C 10010004E 10010005E 10010007C

3 x 10 4 x 10 5 x 10 7 x 10

521 655 798 1063

16.1 17.7 19.8 21.8

10016003C 10016004E 10016005E

3 x 16 4 x 16 5 x 16

920 1095 1379

18.4 20.6 22.9

10025003C 10025004E 10025005E

3 x 25 4 x 25 5 x 25

1371 1592 2012

23.2 25.6 28.4

10035003C 10035004E 10035005E

3 x 35 4 x 35 5 x 35

cables

Part No.

1782 2151 2863

25.7 28.6 31.8

10050003C 10050004E 10050005E

3 x 50 4 x 50 5 x 50

2561 2983 3860

31.1 34.8 38.5

10070003C 10070004E 10070005E

3 x 70 4 x 70 5 x 70

10095003C 10095004E 10095005E

3 x 95 4 x 95 5 x 95

10120004E

4 x 120

10002521 10002525 10002534 10002550

21 x 2.5 25 x 2.5 34 x 2.5 50 x 2.5

737 793 1086 1579

21.5 22.1 23.8 28.9

10004003 10004004 10004005 10004007

3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0

182 235 276 358

9.7 10.6 11.8 13.0

10006003 10006004 10006005 10006007

3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0

273 337 407 498

11.9 12.8 14.3 16.7

10010004 10010005 10010007

4 x 10 5 x 10 7 x 10

532 675 894

15.8 17.9 19.5

10016004 10016005 10016007

4 x 16 5 x 16 7 x 16

849 1053 1389

19.2 21.7 23.8

10025004 10025005 10025007

4 x 25 5 x 25 7 x 25

1275 1580 2109

23.3 25.9 28.5

10035004 10035005

4 x 35 5 x 35

1686 2106

27.3 29.6

10050004

4 x 50

2534

32.1

10070004

4 x 70

3365

36.3

10095004

4 x 95

4535

41.4

10120004

4 x 120

5486

45.3

YY Multicore Cable Colour Coded 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75

41 54 58 69 97 151

5.2 5.7 6.1 6.7 7.2 9.9

10001002C 10001003C 10001004E 10001005E 10001007C 10001012C

2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0

50 60 63 81 126 183

5.5 5.9 6.6 7.1 7.6 10.5

Blue

Brown

3 core

Blue

Brown

Green/Yellow

Tel: 01727 840 841

4 core

Blue

Black

5 core

Blue

Brown

Grey Black

Fax : 01727 840 842

FS

3215 4123 4834 cables 4721 5583 6513

FS

7135

O/D mm

FS

FS

35.5 39.4 44.3cables 41.5 45.9 50.3

FS

52.3

cables

2 core

FS

cables

Colour Code:

Weight kg/km

cables

10000702C 10000703C 10000704E 10000705E 10000707C 10000712C

Cores x mm²

Green/Yellow Grey

Green/Yellow

FS

cables

FS cables


74

SIGNAL & CONTROL LiYY PVC Multicore

LiYY Miniature Signal Cable with DIN 47100 Fire Resistant (IEC 60331) N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, LSHF Power Cable – 0.6/1kV Flexibility is ensured through the use of fine copper wire stranding and pliable PVC compounds. This makes the cable ideal for use on portable or movable equipment or where flexibility will make installation considerably easier. A 600/1000V grade is now available in sizes above 0.75mm2 as are American UL listed versions. Where resistance to water or many oils is required, polyurethane (PUR) jackets offer excellent protection and are available on short lead times. Construction

Technical Information

Fine copper wire strands to IEC 60228 class 5 or class 6

Voltage Rating:

depending on cross section. PVC insulation with DIN 47100 colour coding. Cores twisted together, grey PVC sheath.

0.14mm2 - 0.34mm2: Working 250V Test 1200V 0.5mm2 and above: Working 300/500V Test 3000V Temperature Rating: Static -20°C to +80°C Flexing -5°C to +70°C Minimum Bending Radius: Static 6 x cable diameter Flexing 15 x cable diameter Current Rating:

Part No.

30000325

cables

FS

FS cables

cables

FS

FS cables

Cores x mm²

Weight kg/km

O/D mm

LiYY Miniature Signal Cable with DIN 47100 Colour Code 30000102 2 x 0.14 12 3.3 30000103 3 x 0.14 15 3.5 30000104 4 x 0.14 17 3.7 30000105 5 x 0.14 22 4.0 30000107 7 x 0.14 26 4.7 30000112 12 x 0.14 43 5.7 30000118 18 x 0.14 65 7.2 30000121 21 x 0.14 79 7.5 30000125 25 x 0.14 93 8.1 30000132 32 x 0.14 112 8.8 30000140 40 x 0.14 132 9.6 30000152 52 x 0.14 177 10.9 30000161 61 x 0.14 204 11.6 30000202 30000203 30000204 30000205 30000207 30000212 30000218 30000221 30000225 30000232 30000240 30000252 30000261

2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 7 x 0.25 12 x 0.25 18 x 0.25 21 x 0.25 25 x 0.25 32 x 0.25 40 x 0.25 52 x 0.25 61 x 0.25

25 29 31 38 48 75 110 128 146 186 207 258 324

3.7 3.9 4.2 4.6 5.3 7.1 8.2 8.5 9.8 10.7 11.5 12.8 13.9

Refer to IEE Regs Table 4F3A&B

Part No.

Cores x mm²

Weight kg/km

O/D mm

30000302

2 x 0.34

28

4.4

30000303

3 x 0.34

30

4.6

30000304

4 x 0.34

40

4.9

30000305

5 x 0.34

44

5.6

30000307

7 x 0.34

60

6.2

30000312

12 x 0.34

88

8.1

30000318

18 x 0.34

135

9.7

30000321

21 x 0.34

151

10.4

30000325

25 x 0.34

181

11.5

30000332

32 x 0.34

223

12.4

30000340

40 x 0.34

266

13.5

30000352

52 x 0.34

337

15.5

30000361

61 x 0.34

392

16.5

30000502

2 x 0.5

31

4.9

30000503

3 x 0.5

35

5.2

30000504

4 x 0.5

42

5.7

30000505

5 x 0.5

49

6.2

30000507

7 x 0.5

73

7.2

30000512

12 x 0.5

130

9.2

30000518

18 x 0.5

166

11.3

30000521

21 x 0.5

185

13.1

30000525

25 x 0.5

250

13.4

30000532

32 x 0.5

291

14.7

30000540

40 x 0.5

345

16.1

30000552

52 x 0.5

454

19.7

30000561

61 x 0.5

536

20.4

The cables above are colour coded to DIN 47100. This colour code can be found on page 80. Other core counts and sizes are available please ask for more details. Overall diameters (O/D) are approximate and for guidance only and will vary from one manufacture to another. If the O/D is critical please check at time of order and we will measure it.

www.fscables.com

sales@fscables.com


75

Niltox LF-318 LSHF SIGNAL & CONTROL Niltox® LF-318 LSHF Colour Coded Multicore Low Smoke Halogen Free compounds are used to produce this high quality flexible cable that meets the requirements of 318* B and HO5ZZ-F. Niltox LF-318 is ideal for applications where the cable will be visible. Examples include: lighting pendant drops, supply leads and general wiring in public areas.

3180150300

As an option these cables can be oversheathed in a wide variety of colours in Low Smoke Halogen Free compounds. This is particularly useful when quantities are small or cables are needed quickly.

Construction

Technical Information

Fine copper wire strands to IEC 60228 class

Voltage Rating:

5, halogen free insulation, colour coded to

Temperature Rating: Flexing +5°C to +70°C

300/500V

Test 3000V

Static -20°C to +90°C

BS 7671 HD 308 S2. White or black Low Bending Radius:

Smoke Halogen Free outer sheath.

Flexing 15 x cable diameter Static 7.5 x cable diameter

Current Rating:

Refer to IEE Regs Table 4F3A&B

Flame Retardant:

IEC 60332-1-2

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

Cores x mm²

Weight kg/km

O/D mm

Part No.

Cores x mm²

Weight kg/km

O/D mm

31800702xx

2 x 0.75

60

6.3

31802502xx

2 x 2.5

150

9.1

31800703xx

3 x 0.75

70

6.7

31802503xx

3 x 2.5

184

9.8

31800704xx

4 x 0.75

88

7.1

31802504xx

4 x 2.5

228

10.9

31800705xx

5 x 0.75

112

7.8

31802505xx

5 x 2.5

270

11.9

31801002xx

2 x 1.0

71

6.7

31804003xx

3x4

216

14.0

31801003xx

3 x 1.0

84

7.1

31804004xx

4x4

286

15.1

31801004xx

4 x 1.0

106

7.9

31804005xx

5x4

342

15.4

31801005xx

5 x 1.0

134

8.7

31801006xx

6 x 1.0

163

9.8

31806004xx

4x6

338

15.2

31806005xx

5x6

422

17.5

3180150404

2 x 1.5

97

7.7

31801503xx

3 x 1.5

120

8.3

31810004xx

4 x 10

690

22.1

31801504xx

4 x 1.5

152

9.4

31810005xx

5 x 10

884

24.9

31801505xx

5 x 1.5

183

10.4

31801506xx

6 x 1.5

201

10.1

cables

FS

31801502xx

FS

cables

Part No.

FS

cables

FS

FS

FS

FS

FS

cables

To show the colour required please replace xx in the part number with: 04

White

00

Black

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables


76

SIGNAL & CONTROL Niltox® LF-319 LSHF

® LF-319 LSHF XLPE/Cu/LSHF Niltox Multicore N2XCH-FE180/E90: Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Developed to meet the need for Low Smoke Halogen Free control cables, the Niltox LF-319 range covers all the popular sizes. Applications include airports, hospitals, lift shafts, tunnels, heating and ventilating controls, in fact anywhere that conventional PVC YY cables were previously used. In addition to its LSHF properties this cable offers a high degree of flame retardance thereby reducing the risk of spreading fire. Stocked on bulk reels, Niltox LF-319 cables can be cut to the length you require. Construction

Technical Information

Fine copper wire strands to IEC 60228 class 5, Low Smoke

Voltage Rating: 300/500V Test 2000V Temperature Rating: Flexing +5ºC to +70ºC Static -20ºC to +90ºC Bending Radius: Flexing 15 x cable diameter Static 7.5 x cable diameter Current Rating: Refer to IEE Regs Table 4F3A&B Flame Retardant: IEC 60332-1-2, IEC 60332-3-24C, UL 1685 Smoke Emission: IEC 61034-2, UL 1685 Halogen Emission: IEC 60754-1 & 2

Halogen Free insulation, black cores with white number coding, a green/yellow earth core is included in cables with more than 2 cores, grey Low Smoke Halogen Free outer sheath.

Part No.

Cores x mm²

Weight kg/km

O/D mm

31900703 31901507

31900704 31900705

cables

FS

FS cables

cables

FS

FS cables

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75

45 55 65 76

Cores x mm²

Weight kg/km

O/D mm

31901502

2 x 1.5

73

6.8

5.5

31901503

3 x 1.5

78

7.1

5.6

31901504

4 x 1.5

105

7.6

31901505

5 x 1.5

133

9.0

31901507

7 x 1.5

165

9.5

31901512

12 x 1.5

274

12.0

31901518

18 x 1.5

402

15.5

31901525

25 x 1.5

533

16.5

Number Coded 31900702

Part No.

6.5 7.3

31900707

7 x 0.75

93

7.5

31900712

12 x 0.75

140

9.1

31900718

18 x 0.75

240

12.5

31901534

34 x 1.5

850

19.9

31900725

25 x 0.75

343

14.3

31901550

50 x 1.5

1285

23.9

31900730

30 x 0.75

470

15.5

31901561

61 x 1.5

1475

25.4

31900734

34 x 0.75

225

16.5

31901565

65 x 1.5

1650

26.2

31900741

41 x 0.75

620

17.8

31900750

50 x 0.75

750

19.8

31902502

2 x 2.5

94

7.7

31902503

3 x 2.5

123

8.7

31902504

4 x 2.5

158

9.3

31902505

5 x 2.5

192

10.1

31902507

7 x 2.5

246

12.5

31902512

12 x 2.5

360

13.5

31902518

18 x 2.5

780

18.3

31902525

25 x 2.5

1050

22.1 9.3

31901002

2 x 1.0

49

6.0

31901003

3 x 1.0

59

6.5

31901004

4 x 1.0

75

6.7

31901005

5 x 1.0

88

7.5

31901007

7 x 1.0

112

8.0

31901012

12 x 1.0

170

10.2

31901018

18 x 1.0

252

12.0

31904002

2 x 4.0

172

31901025

25 x 1.0

363

15.0

31904003

3 x 4.0

185

9.9

31901034

34 x 1.0

685

17.6

31904004

4 x 4.0

198

10.1

31901041

41 x 1.0

790

18.8

31904005

5 x 4.0

270

12.5

21.2

31904007

7 x 4.0

475

13.5

31904012

12 x 4.0

800

18.5

31901050

50 x 1.0

870

Also available with a black sheath in some sizes. Other sizes are available on short lead times.

www.fscables.com

sales@fscables.com


77

Niltox® LF-319 LSHF SIGNAL & CONTROL Part No.

Cores x mm²

Weight kg/km

O/D mm

Part No.

Cores x mm²

Weight kg/km

O/D mm

31906002

2 x 6.0

243

10.9

Colour Coded

31906003

3 x 6.0

260

11.5

31906004

4 x 6.0

285

12.0

31901502C

2 x 1.5

73

6.8

31901503C

3 x 1.5

78

31906005

5 x 6.0

420

7.1

14.5

31901504E

4 x 1.5

105

31906007

7 x 6.0

7.6

640

16.2

31901505E

5 x 1.5

133

9.0

31910003 31910004

3 x 10

550

15.1

31902502C

2 x 2.5

94

7.7

4 x 10

710

16.9

31902503C

3 x 2.5

123

31910005

8.7

5 x 10

875

18.9

31902504E

4 x 2.5

158

9.3

31902505E

5 x 2.5

192

10.1

31904003C

3 x 4.0

185

10.0

31904004E

4 x 4.0

198

10.1

31904005E

5 x 4.0

270

12.5

31906003C

3 x 6.0

260

11.5

31906004E

4 x 6.0

285

12.0

31906005E

5 x 6.0

420

14.5

31910003C

3 x 10

550

15.1

31910004C

4 x 10

710

16.9

31910005C

5 x 10

875

18.9

31916003

3 x 16

850

17.8

31916004

4 x 16

1050

20.0

31916005

5 x 16

1300

22.2

31925003

3 x 25

1150

22.6

31925004

4 x 25

1600

25.5

31925005

5 x 25

2100

28.1

31935003

3 x 35

1600

25.5

31935004

4 x 35

2210

28.3

31935005

5 x 35

2700

31.3

31950003

3 x 50

2600

30.0

31916003C

3 x 16

850

17.8

31950004

4 x 50

3100

33.7

31916004C

4 x 16

1050

20.0

31950005

5 x 50

4000

37.4

31916005C

5 x 16

1300

22.2

31970003

3 x 70

3250

37.2

31925003C

3 x 25

1150

22.6

31970004

4 x 70

4100

41.4

31925004C

4 x 25

1600

25.5

31970005

5 x 70

5500

46.2

31925005C

5 x 25

2100

28.1

31995003

3 x 95

4750

41.5

31935003C

3 x 35

1600

25.5

31995004

4 x 95

5600

46.3

31935004C

4 x 35

31995005

5 x 95

7000

50.8

31935005C

5 x 35

FS

FS

FS

2210

28.3

2700

31.3

cables

cables

31912003

3 x 120

5600

46.0

31950003C

3 x 50

2600

30.0

31912004

4 x 120

7150

50.5

31950004C

4 x 50

3100

33.7

31950005C

5 x 50

4000

37.4

2 core

Blue

Brown

3 core

Blue

Brown

Green/Yellow

Tel: 01727 840 841

4 core

Blue

Black

5 core

Blue

Brown

Grey Black

Fax : 01727 840 842

FS

cables

cables

FS

Colour Code:

cables

cables

FS

Green/Yellow Grey

Green/Yellow

FS

cables

FS cables


78

SIGNAL & CONTROL LiYCY PVC

LiYCY PVC Screened Multicore LiYCY has a tinned copper wire braid screen, providing protection from electromagnetic interference (EMI) and reducing electromagnetic radiation (EMR). This can be important when trying to ensure electromagnetic compatibility (EMC). The braid screened LiYCY miniature signal and data cable range is available colour coded to DIN 47100. Larger core sizes over 0.5mm2 are also available number coded or colour coded. These cables are also available unscreened type LiYY with part numbers starting 300 please see page 74, or with the cores twisted into pairs and overall screens known as LiYCY-TP, part numbers starting 325 please see page 80-81; or twisted pairs without a screen LiYY-TP - part numbers starting 305. For Low Smoke Halogen Free types, please see the LF-315 & LF 329 range, pages 84 and pages 82-83 respectively.

Core Identification

Construction Fine copper wire strands to IEC 60228. PVC insulation

0.14mm2 - 0.34mm2. Colour Coded to DIN 47100.

colour or number coded. Cores twisted together with

Part numbers end in F.

overall polyester tape and tinned copper wire braid.

0.5mm2 - 35mm2. Black cores with white numbers + G/Y.

Grey PVC outer sheath.

Part numbers have no suffix. Technical Information Voltage Rating:

32001503C

Temperature Rating:

0.14mm2 - 0.34mm2:

Working 250V

Test 1000V

0.5mm2 - 1.5mm2:

Working 300V

Test 2000V

2.5mm2 - 6mm2:

Working 500V

Test 2000V

Static -20째C to +80째C

Flexing -5째C to +70째C

Minimum Bending Radius: Static 6 x cable diameter Conductor Stranding:

Part No.

Flexing 15 x cable diameter

Flexible to IEC 60228 Class 5 on 0.5mm2 and above.

Cores x mm2

Weight kg/km

O/D mm

Colour Coded to BS7671 HD 308 S2

cables

FS

FS cables

cables

FS

FS cables

32000702C 32000703C 32000704E 32000705E

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75

56 70 95 130

6.7 7.1 7.6 8.2

32001002C 32001003C 32001004E 32001005E

2x1 3x1 4x1 5x1

84 110 130 156

7.7 8.5 9.2 9.9

32001502C 32001503C 32001504E 32001505E

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5

97 125 165 193

8.1 8.9 9.7 10.5

32002502C 32002503C 32002504E 32002505E

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5

148 188 236 270

10.1 10.6 11.6 12.6

32004003C 32004004E 32004005E

3 x 4.0 4 x 4.0 5 x 4.0

250 302 370

12.4 13.5 14.8

www.fscables.com

sales@fscables.com


79

LiYCY PVC SIGNAL & CONTROL Part No.

Cores x mm²

Weight kg/km

O/D mm

17 30 37 44 51 55 60 77 93 104 115 132 137 173 184 190 198 212 238 260 290 333 382

3.7 4.5 5.1 5.2 5.7 6.1 6.4 7.1 8.1 8.4 8.7 8.9 9.4 10.4 11.4 11.5 11.6 11.9 12.7 13.1 14.3 14.9 15.8

32000302F 2 x 0.34 32000303F 3 x 0.34 32000304F 4 x 0.34 32000305F 5 x 0.34 32000306F 6 x 0.34 32000307F 7 x 0.34 32000308F 8 x 0.34 32000310F 10 x 0.34 32000312F 12 x 0.34 32000314F 14 x 0.34 32000316F 16 x 0.34 32000318F 18 x 0.34 32000321F 21 x 0.34 32000325F 25 x 0.34 32000327F 27 x 0.34 32000330F 30 x 0.34 32000336F 36 x 0.34 32000340F 40 x 0.34 32000352F 52 x 0.34 32000361F 61 x 0.34

33 42 49 59 64 69 84 106 119 132 146 188 193 213 232 253 292 318 400 454

32000502 2 x 0.5 32000503 3 x 0.5 32000504 4 x 0.5 32000507 7 x 0.5 32000512 12 x 0.5 32000518 18 x 0.5 32000525 25 x 0.5

42 5.4 51 5.8 61 6.5 98 7.8 156 10.1 215 11.8 314 14.4

32000702 32000703 32000704 32000705 32000707 32000712 32000718 32000725 32000730

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 30 x 0.75

56 70 95 130 168 232 315 418 500

6.7 7.1 7.6 8.2 8.9 12.0 13.9 16.5 18.0

32001002 32001003 32001004 32001005 32001007 32001012 32001018 32001025 32001034

2x1 3x1 4x1 5x1 7x1 12 x 1 18 x 1 25 x 1 34 x 1

84 110 130 156 192 265 380 475 629

7.7 8.5 9.2 9.9 10.7 13.7 15.9 17.5 21.5

Tel: 01727 840 841

5.0 5.4 5.8 6.1 6.6 6.7 7.4 8.5 8.7 9.1 9.6 10.1 10.9 12.0 12.3 12.7 13.6 14.0 15.8 16.6

Part No.

Cores x Weight mm² kg/km

O/D mm

32001502 32001503 32001504 32001505 32001507 32001512 32001518 32001525 32001530 32001542

2 x 1.5 97 3 x 1.5 125 4 x 1.5 165 5 x 1.5 193 7 x 1.5 245 12 x 1.5 365 18 x 1.5 553 25 x 1.5 720 30 x 1.5 776 42 x 1.5 1140

8.1 8.9 9.7 10.5 11.3 14.5 16.9 20.1 20.7 25.5

32002502 32002503 32002504 32002505 32002507 32002512 32002518

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5

148 188 236 270 340 585 725

10.1 10.6 11.6 12.6 13.7 18.5 19.7

32004003 32004004 32004005 32004007

3x4 4x4 5x4 7x4

250 302 370 473

12.4 13.5 14.8 16.1

32006003 32006004 32006005

3x6 4x6 5x6

285 13.9 412 15.2 505 16.7

32000325F

32010004 4 x 10 620 20.8 32010005 5 x 10 796 22.9 32016004 4 x 16 1090 23.2 32016005 5 x 16 2070 25.6

FS

32025004 4 x 25 1787 28.2 32025005 5 x 25 2047 31.1

FS

32035004 4 x 35 2142 31.5

Fax : 01727 840 842

FS

cables

FS

FS

FS

FS

FS

cables

cables

cables

32000201F 1 x 0.25 32000202F 2 x 0.25 32000203F 3 x 0.25 32000204F 4 x 0.25 32000205F 5 x 0.25 32000206F 6 x 0.25 32000207F 7 x 0.25 32000208F 8 x 0.25 32000210F 10 x 0.25 32000212F 12 x 0.25 32000214F 14 x 0.25 32000216F 16 x 0.25 32000218F 18 x 0.25 32000221F 21 x 0.25 32000224F 24 x 0.25 32000225F 25 x 0.25 32000227F 27 x 0.25 32000230F 30 x 0.25 32000236F 36 x 0.25 32000240F 40 x 0.25 32000244F 44 x 0.25 32000252F 52 x 0.25 32000261F 61 x 0.25

O/D mm

cables

3.6 3.8 4.0 4.3 4.6 5.0 5.2 5.6 6.3 6.4 6.7 7.2 7.6 8.3 9.0 9.0 9.1 9.4 10.0 10.3 11.1 11.5 12.1

Weight kg/km

cables

16 20 25 30 36 40 41 44 56 60 65 81 93 103 117 120 124 136 160 170 186 200 250

Cores x mm²

cables

32000101F 1 x 0.14 32000102F 2 x 0.14 32000103F 3 x 0.14 32000104F 4 x 0.14 32000105F 5 x 0.14 32000106F 6 x 0.14 32000107F 7 x 0.14 32000108F 8 x 0.14 32000110F 10 x 0.14 32000112F 12 x 0.14 32000114F 14 x 0.14 32000116F 16 x 0.14 32000118F 18 x 0.14 32000121F 21 x 0.14 32000124F 24 x 0.14 32000125F 25 x 0.14 32000127F 27 x 0.14 32000130F 30 x 0.14 32000136F 36 x 0.14 32000140F 40 x 0.14 32000144F 44 x 0.14 32000152F 52 x 0.14 32000161F 61 x 0.14

Part No.

cables


80

SIGNAL & CONTROL LiYCY TP PVC

LiYCY TP PVC Screened Paired Cables Popular as a European alternative to the American style data cables, LiYCY-TP has the cores twisted into pairs to reduce cross talk. The DIN 47100 colour code makes it easy to identify each conductor. The effects of electro magnetic interference (EMI) are also minimised by the use of an overall tinned copper wire braid screen. Used extensively for signal & data transmission where flexibility is important LiYCY-TP are designed for fixed or occasional movement although the cable construction make installation and routing through confined spaces simple.

Construction

Technical Information

Plain copper wire conductors to IEC 60228 class 5, PVC

Voltage Rating:

≤ 0.34mm² = 300V ≥ 0.5mm² = 300/500V

insulation, cores twisted in pairs, overall tinned copper wire braid, PVC sheath – Grey. LiHCH-TP which is an LSHF version is also available, please see page 85 for more details.

Conductor Stranding:

Stranded to IEC 60228 class 5

Temperature Rating:

Static -30°C to +80°C Flexing -5 to +70°C

Bending Radius:

Static 5 x overall diameter Flexing 10 x overall diameter

Flame Retardant:

VDE 0472 test B, IEC 60332-1-2, EN 50265-2-1

Manufactured To:

VDE 0814

Colour code:

DIN 47100

32500506F

DIN 47100 European Colour Codes The DIN 47100 standard specifies the core colour for up to 44 cores. Above this it is usual practice to repeat the colours. The first colour is the colour of the base insulation and the second colour is that of either a longitudinal stripe or printed rings.

cables

FS

FS cables

White

16

Yellow/Brown

31

Green/Blue

2

Brown

17

White/Grey

32

Yellow/Blue

3

Green

18

Grey/Brown

33

Green/Red

4

Yellow

19

White/Pink

34

Yellow/Red

5

Grey

20

Pink/Brown

35

Green/Black

6

Pink

21

White/Blue

36

Yellow/Black

7

Blue

22

Brown/Blue

37

Grey/Blue

8

Red

23

White/Red

38

Pink/Blue

9

Black

24

Brown/Red

39

Grey/Red

10

Violet

25

White/Black

40

Pink/Red

11

Grey/Pink

26

Brown/Black

41

Grey/Black

12

Red/Blue

27

Grey/Green

42

Pink/Black

13

White/Green

28

Yellow/Grey

43

Blue/Black

14

Brown/Green

29

Pink/Green

44

Red/Black

15

White/Yellow

30

Yellow/Pink

cables

FS

1

FS cables

www.fscables.com

sales@fscables.com


81

LiYCY TP PVC SIGNAL & CONTROL Part No.

Pairs x mm2

Weight kg/km

O/D mm

Part No.

Pairs x mm2

32500302F 32500303F 32500304F 32500305F 32500306F 32500307F 32500308F 32500310F 32500312F 32500314F 32500316F 32500318F 32500321F 32500325F 32500330F 32500334F 32500340F 32500344F 32500350F

2 x 2 x 0.34 3 x 2 x 0.34 4 x 2 x 0.34 5 x 2 x 0.34 6 x 2 x 0.34 7 x 2 x 0.34 8 x 2 x 0.34 10 x 2 x 0.34 12 x 2 x 0.34 14 x 2 x 0.34 16 x 2 x 0.34 18 x 2 x 0.34 21 x 2 x 0.34 25 x 2 x 0.34 30 x 2 x 0.34 34 x 2 x 0.34 40 x 2 x 0.34 44 x 2 x 0.34 50 x 2 x 0.34

65 87 115 121 139 149 165 232 239 248 267 296 308 410 451 525 623 648 714

7.1 7.8 8.5 9.4 9.9 10.1 10.9 12.2 13.3 13.6 14.6 15.7 16.3 18.1 19.2 20.3 21.6 22.4 23.8

32500502F 32500503F 32500504F 32500505F 32500506F 32500508F 32500510F 32500512F 32500516F 32500520F 32500525F 32500532F

2 x 2 x 0.50 3 x 2 x 0.50 4 x 2 x 0.50 5 x 2 x 0.50 6 x 2 x 0.50 8 x 2 x 0.50 10 x 2 x 0.50 12 x 2 x 0.50 16 x 2 x 0.50 20 x 2 x 0.50 25 x 2 x 0.50 32 x 2 x 0.50

102 135 159 168 210 268 315 355 475 532 623 810

7.8 8.4 9.5 9.9 11.3 12.2 13.6 14.4 16.8 18.5 20.2 22.5

32500702F 32500703F 32500704F 32500705F 32500706F 32500708F 32500710F 32500712F 32500716F 32500720F 32500725F

2 x 2 x 0.75 109 3 x 2 x 0.75 142 4 x 2 x 0.75 179 5 x 2 x 0.75 218 6 x 2 x 0.75 247 8 x 2 x 0.75 306 10 x 2 x 0.75 356 12 x 2 x 0.75 410 16 x 2 x 0.75cables 550 20 x 2 x 0.75 686 25 x 2 x 0.75 810

32500202F 32500203F 32500204F 32500205F 32500206F 32500207F 32500208F 32500210F 32500212F 32500214F 32500216F 32500218F 32500220F 32500224F 32500225F 32500226F 32500230F 32500232F 32500234F 32500236F 32500240F 32500244F 32500246F 32500250F

2 x 2 x 0.25 3 x 2 x 0.25 4 x 2 x 0.25 5 x 2 x 0.25 6 x 2 x 0.25 7 x 2 x 0.25 8 x 2 x 0.25 10 x 2 x 0.25 12 x 2 x 0.25 14 x 2 x 0.25 16 x 2 x 0.25 18 x 2 x 0.25 20 x 2 x 0.25 24 x 2 x 0.25 25 x 2 x 0.25 26 x 2 x 0.25 30 x 2 x 0.25 32 x 2 x 0.25 34 x 2 x 0.25 36 x 2 x 0.25 40 x 2 x 0.25 44 x 2 x 0.25 46 x 2 x 0.25 50 x 2 x 0.25

47 58 75 90 101 123 130 168 196 218 221 250 278 334 337 346 375 403 412 421 489 508 540 640

6.2 6.7 7.5 8.1 8.5 9.0 9.4 10.3 10.9 12.1 12.5 13.4 13.7 14.6 15.2 15.8 16.6 16.9 17.5 17.9 18.4 19.1 19.4 20.5

Tel: 01727 840 841

32501002F 32501003F 32501004F 32501502F 32501503F 32501504F

Fax : 01727 840 842

FS

FS

2 x 2 x 1.0 3 x 2 x 1.0 4 x 2 x 1.0 2 x 2 x 1.5 3 x 2 x 1.5 4 x 2 x 1.5

125 165 220 172 231 270

FS

8.5 9.4 10.2 11.6 12.2 13.5 15.2 16.5 19.0 cables 21.3 22.9

FS

FS

9.2 10.3 11.1 10.3 12.4 13.7

FS

FS

cables

FS

cables

5.4 6.0 6.5 7.2 7.6 7.7 8.2 9.0 9.5 10.1 10.6 11.3 11.6 12.5 12.9 13.1 13.5 13.6 14.6 14.7 15.5 16.2 16.5 17.5

O/D mm

cables

42 51 58 77 86 88 104 128 142 160 156 178 195 239 243 249 287 298 321 330 372 385 433 450

cables

2 x 2 x 0.14 3 x 2 x 0.14 4 x 2 x 0.14 5 x 2 x 0.14 6 x 2 x 0.14 7 x 2 x 0.14 8 x 2 x 0.14 10 x 2 x 0.14 12 x 2 x 0.14 14 x 2 x 0.14 16 x 2 x 0.14 18 x 2 x 0.14 20 x 2 x 0.14 24 x 2 x 0.14 25 x 2 x 0.14 26 x 2 x 0.14 30 x 2 x 0.14 32 x 2 x 0.14 34 x 2 x 0.14 36 x 2 x 0.14 40 x 2 x 0.14 44 x 2 x 0.14 46 x 2 x 0.14 50 x 2 x 0.14

cables

32500102F 32500103F 32500104F 32500105F 32500106F 32500107F 32500108F 32500110F 32500112F 32500114F 32500116F 32500118F 32500120F 32500124F 32500125F 32500126F 32500130F 32500132F 32500134F 32500136F 32500140F 32500144F 32500146F 32500150F

Weight kg/km

cables


82

SIGNAL & CONTROL Niltox® LF-329 LSHF

Niltox® LF-329 Dual Screened LSHF Multicore Niltox LF-329 is a Low Smoke Halogen Free alternative to the popular PVC LiYCY screened signal, control & power cable. Available from 0.75mm2 to 120mm2 these cables are LSHF throughout. Flexibility is excellent making installation easy. Core identification is straightforward with cores being clearly number coded and a green/yellow earth core included in cables with more than 2 cores. Applications include hospitals, airports, computer suites and control rooms, in fact anywhere where power or signals need to be protected from electromagnetic radiation or from corrupting other cables or equipment. The LSHF properties protect both people and equipment.

Construction

Technical Information

Fine copper wire strands to IEC 60228 class 5,

Voltage Rating:

Low Smoke Halogen Free insulation, cores twisted

Temperature Rating: Flexing +5°C to +70°C

300/500V

Static -20°C to +90°C

together, polyester tape, overall foil & tinned Bending Radius:

copper wire braid, grey Low Smoke Halogen Free

Flexing 10 x cable diameter Static 7.5 x cable diameter

sheath. Cores are black with white numbers, a green/yellow earth core is included in cables with more than 2 cores.

Part No.

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-24C, UL 1685

Smoke Emission:

IEC 61034-2, UL 1685

Halogen Emission:

IEC 60754-1 & 2

Cores x mm²

Weight kg/km

O/D mm

Cores x mm²

Weight kg/km

O/D mm

32900702

2 x 0.75

56

6.5

32902502

2 x 2.5

123

8.3

32902503

3 x 2.5

132

32900703

3 x 0.75

54

9.2

6.0

32902504

4 x 2.5

152

32900704

4 x 0.75

74

9.5

6.5

32902505

5 x 2.5

215

10.9

32900705

5 x 0.75

83

7.6

32900707

7 x 0.75

106

8.1

32902507

7 x 2.5

250

12.0

32902512

12 x 2.5

580

32900712

12 x 0.75

200

10.3

15.9

32900718

18 x 0.75

295

12.5

32900725

25 x 0.75

420

14.8

32904002

2 x 4.0

190

10.0

32904003

3 x 4.0

220

11.5

Number Coded 32900707

cables

FS

FS cables

cables

FS

FS cables

Test 2000V

Part No.

32901002

2 x 1.0

60

6.6

32904004

4 x 4.0

310

11.6

32901003

3 x 1.0

66

6.6

32904005

5 x 4.0

395

12.7

32901004

4 x 1.0

83

7.4

32904007

7 x 4.0

510

14.1

32901005

5 x 1.0

100

8.1

32901007

7 x 1.0

130

9.0

32906002

2 x 6.0

280

11.6

32901012

12 x 1.0

270

11.3

32906003

3 x 6.0

325

12.5

32901018

18 x 1.0

390

13.4

32906004

4 x 6.0

360

13.6

32901025

25 x 1.0

545

15.9

32906005

5 x 6.0

520

15.9

32906007

7 x 6.0

675

16.7

32910003

3 x 10

450

15.5

9.1

32910004

4 x 10

790

17.4

5 x 10

620

18.0

32901502

2 x 1.5

32901503 32901504 32901505

72

7.1

3 x 1.5

97

8.1

4 x 1.5

114

8.6

5 x 1.5

135

32901507

7 x 1.5

176

9.7

32910005

32901512

12 x 1.5

300

12.7

32916003

3 x 16

690

19.0

32901518

18 x 1.5

500

14.8

32916004

4 x 16

1300

22.7

32901525

25 x 1.5

710

17.8

32916005

5 x 16

2200

25.3

www.fscables.com

sales@fscables.com


83

Niltox® LF-329 LSHF SIGNAL & CONTROL Part No.

Cores x mm²

Weight kg/km

O/D mm

32925003

3 x 25

1450

23.3

Colour Coded

32925004

4 x 25

1950

26.4

32901502C

2 x 1.5

72

7.1

32901503C

3 x 1.5

97

8.1

32901504C

4 x 1.5

114

8.6

32901505C

5 x 1.5

135

9.1

32925005

5 x 25

2450

Part No.

29.5

Cores x mm²

Weight kg/km

O/D mm

32935003

3 x 35

2000

25.9

32935004

4 x 35

2575

30.5

32902502C

2 x 2.5

123

8.3

32935005

5 x 35

3200

34.0

32902503C

3 x 2.5

132

9.2

32902504C

4 x 2.5

152

9.5

32902505C

5 x 2.5

215

10.9

32904003C

3 x 4.0

220

11.5

32904004E

4 x 4.0

310

11.6

32904005E

5 x 4.0

395

12.7

32950003

3 x 50

3100

30.2

32950004

4 x 50

3600

34.8

32950005

5 x 50

4800

40.0

32970003

3 x 70

3900

37.8

32970004

4 x 70

5000

41.4

32906003C

3 x 6.0

325

12.5

32970005

5 x 70

6600

46.3

32906004E

4 x 6.0

360

13.6

32906005E

5 x 6.0

520

15.9

32910003C

3 x 10

450

15.5

32910004E

4 x 10

790

17.9

620

18.0

32995003

3 x 95

5700

41.3

32995004

4 x 95

6700

46.4

32995005

5 x 95

8400

51.5

32910005E

5 x 10

32912003

3 x 120

6400

46.7

32916003C

3 x 16

690

19.0

32916004E

4 x 16

1300

22.7

32916005E

5 x 16

32925003C

3 x 25

32925004E 32925005E

32935003C

3 x 35

32935004E 32935005E

32912004

4 x 120

8500

51.2

23.3

4 x 25

1950

26.4

5 x 25

2450

29.5

2000 cables

25.9

4 x 35

2575

30.5

5 x 35

3200

34.0

Blue

Brown

Green/Yellow

Tel: 01727 840 841

Blue

Black

5 core

Blue

Brown

Grey

FS

Black

Fax : 01727 840 842

Green/Yellow Grey

FS cables

FS

cables

3 core

4 core

cables

Brown

FS

cables

1450

cables

Blue

FS

25.3

Colour Code: 2 core

FS

2200

Green/Yellow

FS

cables

FS cables


84

SIGNAL & CONTROL Niltox® LF-315 LSHF

Niltox® LF-315 Screened LSHF Multicore Developed for signal and control applications in sensitive areas, the Niltox LF-315 range offers excellent flame retardance while emitting no halogens or other corrosive gases when exposed to fire. These cables are colour coded to the DIN 47100 standard and offer excellent flexibility and durability. Construction

Technical Information

Fine copper wire strands to IEC 60228. Low Smoke

Voltage Rating:

0.14mm2:

Halogen Free insulation, colour coded cores twisted

300V

together with overall PETP tape and tinned copper wire

0.25mm2 to 1.5mm2:

Test 800V

300/500V

braid. Flame retardant halogen free light grey sheath. Temperature Rating:

Test 1200V

Flexing -5°C to +70°C Static -40°C to +80°C

Bending Radius:

Flexing 15 x cable diameter Static 7.5 x cable diameter

31500712

cables

FS

FS cables

cables

FS

Flame Retardant:

IEC 60332-1-2

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

Colour Code:

DIN 47100 see page 80.

Part No.

Cores x mm²

Weight kg/km

O/D mm

Part No.

Cores x mm²

Weight kg/km

O/D mm

31500102

2 x 0.14

18

3.9

31500502

2 x 0.5

42

5.3

31500103

3 x 0.14

22

4.1

31500503

3 x 0.5

49

5.6

31500104

4 x 0.14

24

4.3

31500504

4 x 0.5

64

6.2

31500105

5 x 0.14

29

4.7

31500505

5 x 0.5

79

6.9

31500107

7 x 0.14

32

5.2

31500507

7 x 0.5

99

7.4

31500110

10 x 0.14

46

6.5

31500512

12 x 0.5

142

9.8

31500112

12 x 0.14

53

6.9

31500118

18 x 0.14

72

7.8

31500702

2 x 0.75

49

5.9

31500703

3 x 0.75

64

6.4

31500202

2 x 0.25

21

4.3

31500704

4 x 0.75

81

7.1

31500203

3 x 0.25

23

4.4

31500705

5 x 0.75

106

7.7

31500204

4 x 0.25

27

4.7

31500707

7 x 0.75

122

8.7

31500205

5 x 0.25

34

5.3

31500712

12 x 0.75

187

11.0

31500207

7 x 0.25

41

5.7

31500210

10 x 0.25

55

7.3

31501002

2 x 1.0

61

6.1

31500212

12 x 0.25

64

7.5

31501003

3 x 1.0

82

6.8

31500218

18 x 0.25

89

9.0

31501004

4 x 1.0

102

7.2

31501005

5 x 1.0

119

8.4

31500302

2 x 0.34

25

5.0

31501007

7 x 1.0

149

9.1

31500303

3 x 0.34

30

5.2

31500304

4 x 0.34

36

5.6

31501502

2 x 1.5

76

7.1

31500305

5 x 0.34

44

6.3

31501503

3 x 1.5

104

7.9

31500307

7 x 0.34

54

6.9

31501504

4 x 1.5

117

8.4

31500310

10 x 0.34

76

8.9

31501505

5 x 1.5

149

9.3

31500312

12 x 0.34

86

9.1

31501507

7 x 1.5

188

10.4

Other sizes and numbers of cores are often available on short delivery times, please ask for details.

FS cables

www.fscables.com

sales@fscables.com


85

Niltox® LF-316 LSHF SIGNAL & CONTROL ® LF-316 Screened Niltox LSHF Multipair N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

The Niltox LF-316 paired and screened range of Low Smoke Halogen Free data cables offer excellent flexibility and durability. Identification of the cores is made easy due to the DIN 47100 colour code. The cable is screened with an overall tinned copper wire braid offering excellent protection from electromagnetic interference. Construction

Technical Information

Fine copper wire strands to IEC 60228. Low Smoke

Voltage Rating:

0.14mm2:

Halogen Free insulation, colour coded, two cores

350V

twisted together to form a pair, pairs then twisted

0.25mm2 to 0.75mm2:

Test 800V

500V

together to form multipair cables, overall PETP tape and overall tinned copper wire braid. Flame retardant

Temperature Rating:

Test 1200V

Flexing +5°C to +70°C Static -40°C to +70°C

halogen free grey sheath. Bending Radius:

7.5 x cable diameter

Flame Retardant:

IEC 60332-1-2

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

Colour Code:

DIN 47100 see page 80.

Part No.

Pairs x mm2

Weight kg/km

O/D mm

Part No.

Pairs x mm2

Weight kg/km

O/D mm

31600102

2 x 2 x 0.14

36

5.3

31600501

1 x 2 x 0.5

42

31600103

3 x 2 x 0.14

47

6.2

31600502

2 x 2 x 0.5

76

7.6

31600104

4 x 2 x 0.14

65

7.4

31600503

3 x 2 x 0.5

108

8.9

31600106

6 x 2 x 0.14

86

8.1

31600504

4 x 2 x 0.5

135

10.3

31600505

5 x 2 x 0.5

152

11.5

31600506

6 x 2 x 0.5

168

11.7

31600507

7 x 2 x 0.5

186

11.9

31600512

12 x 2 x 0.5

331

16.0

5.5

7 x 2 x 0.14

94

8.7

31600112

12 x 2 x 0.14

134

10.7

31600201

1 x 2 x 0.25

21

4.5

31600202

2 x 2 x 0.25

44

5.9

31600203

3 x 2 x 0.25

65

7.1

31600204

4 x 2 x 0.25

80

8.0

31600702

2 x 2 x 0.75

106

9.1

3 x 2 x 0.75

138

10.0

6 x 2 x 0.25

114

9.0

31600207

7 x 2 x 0.25

121

9.4

31600704

4 x 2 x 0.75

165

11.6

31600212

12 x 2 x 0.25

173

11.0

31600705

5 x 2 x 0.75

234

13.5

31600707

7 x 2 x 0.75

259

13.8

31600712

12 x 2 x 0.75

439

18.4

31600302

2 x 2 x 0.34

67

7.3

31600303

3 x 2 x 0.34

91

8.5

31600304

4 x 2 x 0.34

109

9.5

31600306

6 x 2 x 0.34

140

10.0

31600307

7 x 2 x 0.34

155

11.0

31600312

12 x 2 x 0.34

246

14.5

cables

FS

31600206

31600703

FS

cables

31600107

31600506

cables

FS

FS

FS

FS

FS

cables

cables

cables

FS

Other sizes and pair counts are often available on short delivery times, please ask for details.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


86

SIGNAL & CONTROL RiserFlex 0.6/1kV RiserFlex 0.6/1kV Developed to meet the latest building requirements this Low Smoke Halogen Free cable is 0.6/1kV rated making it ideal to run in risers or under floors.

32801504E

The conductors are finely stranded to IEC60228 class 5 making installation simple and routing easy. Cores are colour coded to BS7671 in cables up to 5 cores. Above this they are black with white numbers. Cores are also rated at 0.6/1kV to comply with regulations for power cables in protected installations. Applications include wiring to computer systems, lift shafts, HVAC, security systems and BMS. Construction

Technical Information

Fine copper wire strands to IEC

Voltage Rating:

Working 0.6/1kV

60228 class 5, XLPE insulation, cores

Temperature Rating:

Static -20ºC to +80ºC

laid up. Low Smoke Halogen Free

Bending Radius:

Static 7.5 x cable diameter

sheath – black.

Flame Retardant:

IEC 60332-1-2

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

Oxygen Index:

>30% Up to 5 core in accordance with BS7671. Above 5 core, black numbered cores & G/Y earth

Core Identification:

Part No.

32802507

cables

FS

FS cables

Weight kg/km

O/D mm

32800702 32800703 32800704 32800705 32800707

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75

63 74 93 118 147

6.0 6.6 7.1 8.0 9.4

32801002

2x1

75

8.9

32801003

3x1

89

7.4

32801004

4x1

112

8.2

32801005 32801007

5x1 7x1

141 178

9.0 10.0

32801502 32801503

2 x 1.5 3 x 1.5

102 126

7.9 8.6

32801504

4 x 1.5

159

9.3

32801505

5 x 1.5

192

10.4

32801507 32801512

7 x 1.5 12 x 1.5

231 390

11.1 16.6

Part No.

Cores x mm²

Weight kg/km

O/D mm

32802502 32802503 32802504 32802505 32802507

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5

158 194 240 284 361

9.3 9.7 10.8 12.2 13.1

32804003 32804004 32806003 32806004

3x4 4x4 3x6 4x6

228 299 301 356

12.3 13.8 14.1 15.6

32810003 32810004

3 x 10 4 x 10

684 882

16.5 18.4

cables

FS

Cores x mm²

Test 3.5kV

FS cables

www.fscables.com

sales@fscables.com


87

RiserShield 0.6/1kV SIGNAL & CONTROL RiserShield 0.6/1kV RiserShield is a 0.6/1kV dual screened power, control and signal cable using Low Smoke Halogen Free materials throughout. Developed to run alongside power cables RiserShield is particularly popular for running clean supplies to computer equipment.

42601507

The double shield is effective at reducing both radiated and induced interference. The class 5 flexible conductors ensure the cable can be easily routed even through confined spaces.

Construction

Technical Information

Fine copper wire strands to IEC

Voltage Rating:

Working 0.6/1kV

60228 class 5, XLPE insulation, cores

Temperature Rating:

Static -40ºC to +80ºC

laid up, overall foil and tinned copper

Bending Radius:

Static 7.5 x cable diameter

braid. Low Smoke Halogen Free

Flame Retardant:

IEC 60332-1-2

sheath – black.

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

Oxygen Index:

>30% Up to 5 core in accordance with BS7671. Above 5 core, black numbered cores & G/Y earth

Core Identification:

Part No.

O/D mm

42600702

2 x 0.75

105

7.1

42600703

3 x 0.75

111

7.5

42600704

4 x 0.75

132

8.1

42600705

5 x 0.75

149

9.0

42600707

7 x 0.75

215

9.8

42601002

2x1

126

7.8

42601003

3x1

141

8.3

42601004

4x1

167

9.1

42601005

5x1

196

10.1

42601007

7x1

282

10.9

42601502

2 x 1.5

149

8.9

42601503

3 x 1.5

173

9.5

42601504

4 x 1.5

191

10.3

42601505

5 x 1.5

216

11.3

42601507

7 x 1.5

314

12.2

Part No.

Cores x mm²

Weight kg/km

O/D mm

42602502 42602503 42602504 42602505 42602507

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5

206 263 299 329 471

10.3 10.8 11.9 13.0 14.4

42604003 42604004

3x4 4x4

295 376

16.2 17.4

42606003 42606004

3x6 4x6

390 459

19.2 20.8

42610003 42610004

3 x 10 4 x 10

882 1049

42606004E

FS

FS

FS

cables

FS

FS

FS

FS

FS

25.3 28.6

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

Weight kg/km

cables

Cores x mm²

Test 3.5kV

cables


88

SIGNAL & CONTROL Def-Standard PVC

Def-Standard PVC Multicore Originally developed for military use, these cables are now widely used within industry. They offer compact sizing, high working voltage and a large range of sizes to suit most applications. A robust and economical choice which can also be oversheathed or armoured for duct installation or direct burial. These cables should not be used as mains connection cables. Applications include data processing, information transfer, process control and security as well as many industrial applications. Construction Unscreened type 'A' has fine tinned copper wire strands, colour coded PVC insulation, cores twisted together, PVC outer sheath. Screened type 'C' has an overall polyester tape with tinned copper wire braid screen. Screened type 'S' has an overall aluminium/polyester foil screen and tinned copper drain wire. Individually Screened type 'D' has a tinned copper wire braid screen around each core. Duct grade versions have a heavy duty black LDPE sheath over the standard PVC sheath. Type ‘R’ uses 37 x 0.315mm stranding (2.9mm2) and has a overall tinned copper wire braid like type C. Normally packed on 100m, 500m or 1000m spools, cables can also be cut to length when required. For colour codes up to 36 cores see page 167. Part No.

Size

No. of Cores

Weight kg/km

O/D mm

2 3 4 6 9 12 15 18 25 36 50

7 8 10 14 18 24 27 32 42 63 76

2.5 2.6 2.8 3.3 3.9 4.3 4.5 5.4 5.8 6.4 7.3

2 3 4 6 8 9 12 15 18 25 36 50

9 11 17 22 25 27 44 46 54 64 83 114

3.0 3.2 3.4 3.8 4.2 4.4 4.6 5.4 5.8 6.6 7.2 8.3

2 3 4 6 8 12 18 20 25 36

14 17 22 32 47 56 82 90 100 146

3.4 3.5 3.8 4.8 5.6 6.4 7.4 7.8 8.7 9.8

Unscreened 7/0.1mm - 0.055mm2

39300212

39200102 39200103 39200104 39200106 39200109 39200112 39200115 39200118 39200125 39200136 39200150

7-1-2A 7-1-3A 7-1-4A 7-1-6A 7-1-9A 7-1-12A 7-1-15A 7-1-18A 7-1-25A 7-1-36A 7-1-50A

Braid Screen 7/0.1mm - 0.055mm2 cables

FS

FS cables

39300102 39300103 39300104 39300106 39300108 39300109 39300112 39300115 39300118 39300125 39300136 39300150

7-1-2C 7-1-3C 7-1-4C 7-1-6C 7-1-8C 7-1-9C 7-1-12C 7-1-15C 7-1-18C 7-1-25C 7-1-36C 7-1-50C

Unscreened 7/0.2mm - 0.22mm2

cables

FS

FS cables

39200202 39200203 39200204 39200206 39200208 39200212 39200218 39200220 39200225 39200236

7-2-2A 7-2-3A 7-2-4A 7-2-6A 7-2-8A 7-2-12A 7-2-18A 7-2-20A 7-2-25A 7-2-36A

www.fscables.com

sales@fscables.com


89

Def-Standard PVC SIGNAL & CONTROL Technical Information Voltage Rating: Temperature Rating: Bend Radius: Current Rating: Nominal Conductor Max. Resistance @ 20째C:

Part No.

Size

0.055mm2 0.22mm2,0.5mm2 & 2.9mm2 0째C to +70째C Static 7.5 cable diameter 0.055mm2 0.25 amps 0.055mm2 348 Ohm/km 2.9mm2 6.79 Ohm/km

No. of Cores

Weight kg/km

O/D mm

250V rms up to 1600Hz 440V rms up to 1600Hz

39400508 0.22mm2 1 amp

0.5mm2 2.5 amps

0.22mm2 92 Ohm/km

0.5mm2 40.1 Ohm/km

Part No.

Size

No. of Cores

Weight kg/km

O/D mm

Unscreened 16/0.2mm - 0.5mm2

Unscreened Duct 7/0.2mm - 0.22mm2 39200206D 7-2-6A

6

52

6.8

39200502

16-2-2A

2

35

5.5

39200208D 7-2-8A

8

56

7.1

39200503

16-2-3A

3

42

5.8

39200212D 7-2-12A

12

68

8.4

39200504

16-2-4A

4

54

6.3

39200506

16-2-6A

6

76

7.3

39200508

16-2-8A

8

88

8.6

39200512

16-2-12A

12

120

9.5

39200518

16-2-18A

18

180

11.0

39200525

16-2-25A

25

265

12.5

39200536

16-2-36A

36

341

14.1 6.5

Foil Screened Duct 7/0.2mm - 0.22mm2 39400206D 7-2-6S

6

53

7.1

39400208D 7-2-8S

8

58

7.6

39400212D 7-2-12S

12

72

9.0

Braid Screen 7/0.2mm - 0.22mm2 39300202

7-2-2C

2

25

3.8

39300203

7-2-3C

3

29

4.0

39300204

7-2-4C

4

33

4.3

39300206

7-2-6C

6

57

Braid Screen 16/0.2mm - 0.5mm2 39300502

16-2-2C

2

71

39300503

16-2-3C

3

82

6.8

5.6

39300504

16-2-4C

4

97

7.3 8.3

39300208

7-2-8C

8

66

6.2

39300506

16-2-6C

6

130

39300212

7-2-12C

12

87

6.9

39300508

16-2-8C

8

152

8.8

39300215

7-2-15C

15

105

7.6

39300512

16-2-12C

12

202

10.5

39300218

7-2-18C

18

115

8.4

39300518

16-2-18C

18

270

12.0

39300220

7-2-20C

20

124

8.6

39300525

16-2-25C

25

350

14.1

39300225

7-2-25C

25

153

9.5

39300536

16-2-36C

36

475

16.1

39300236

7-2-36C

36

207

10.7

Ind. Braid Screen Cores 16/0.2mm - 0.5mm2 16-2-4D

4

93

7.5

7-2-2S

2

23

3.7

39600506

16-2-6D

6

121

8.8

39400203

7-2-3S

3

28

4.0

39600507

16-2-7D

7

134

39600512

16-2-12D

12

188

7-2-4S

4

31

4.1

39400206

7-2-6S

6

52

4.8

39400208

7-2-8S

8

60

5.7

39400212

7-2-12S

12

79

6.2

39400218

7-2-18S

18

103

7.9

39400225

7-2-25S

25

141

39400236

7-2-36S

36

175

FS

Foil Screen Cored or Paired 16/0.2mm - 0.5mm2 39400501P

16-2-1PS 1 Pair

38

5.2

39400502P

16-2-2PS 2 Pair

79

7.9

39400502

16-2-2S

2

47

5.0

39400503

16-2-3S

3

56

8.8

39400504

16-2-4S

4

61

10.5

39400506

16-2-6S

6

75

39400508

16-2-8S

8

89

Ind. Braid Screen Cores 7/0.2mm - 0.22mm2

FS 6.0 6.8

cables 7.6

2

21

4.3

39400512

16-2-12S

12

132

9.7

7-2-3D

3

28

4.6

39400518

16-2-18S

18

198

12.6

39600204

7-2-4D

4

38

5.1

39400525

16-2-25S

25

269

14.0

39600206

7-2-6D

6

56

6.0

39400536

16-2-36S

36

387

39600212

7-2-12D

12

112

8.2

39600218

7-2-18D

18

151

9.5

37-3-2R

2

150

39302903

37-3-3R

3

200

10.5

39302904

37-3-4R

4

250

11.0

15.9

cables

39302902

FS

Fax : 01727 840 842

FS cables

6.8

FS

cables

FS

cables

7-2-2D

39600203

Braid Screen 37/0.315mm - 2.9mm2

FS

8.2

39600202

Tel: 01727 840 841

cables

39400204

8.9

11.1

cables

39600504

39400202

Foil Screened 7/0.2mm - 0.22mm2

FS cables


90

SIGNAL & CONTROL Def-Standard LSHF

Def-Standard LSHF Multicore For installations that call for Low Smoke Halogen Free signal cables the Niltox range of LSHF miniature multicores are the ideal solution. Manufactured in the style of the Def Style PVC multicores on pages 88-89, these cables are suitable for use in public buildings & sensitive areas as they contain no Halogen emitting compounds. Screened and unscreened options are held in stock. This cable is not suitable for direct connection to the mains. Construction

Technical Information

Fine tinned copper wire strands, colour coded Low

Voltage Rating:

440V rms up to 1600Hz

Smoke Halogen Free insulation, cores laid-up with

Temperature Rating:

0ยบC to +70ยบC

a Low Smoke Halogen Free outer sheath. Screened type

Current Rating:

0.22mm2 1amp

'C' has a polyester tape with a tinned copper braid

Nominal Conductor

screen. Screened type 'S' has an aluminium foil screen

Max. Resistance @ 20ยบC: 0.22mm2 - 92 ohms per km 0.5mm2 - 40.1 ohms per km

and tinned copper drain wire.

Part No.

Size

No. of Cores

Weight kg/km

Bending Radius:

Static 7.5 x cable diameter.

Flame Retardant:

IEC 60332-1-2

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

O/D mm

LSHF Unscreened 7/0.2mm - 0.22mm2

39200206H

cables

FS cables

cables

FS

FS cables

Part No.

Size

No. of Cores

Weight kg/km

O/D mm

LSHF Unscreened 16/0.2mm - 0.5mm2

39200202H

7-2-2A

2

14

3.4

39200502H

16-2-2A

2

35

5.5

39200203H

7-2-3A

3

17

3.5

39200503H

16-2-3A

3

42

5.8

39200204H

7-2-4A

4

22

3.8

39200504H

16-2-4A

4

54

6.3

39200206H

7-2-6A

6

32

4.8

39200506H

16-2-6A

6

76

7.3

39200208H

7-2-8A

8

47

5.6

39200508H

16-2-8A

8

96

8.6

39200212H

7-2-12A

12

56

6.4

39200512H

16-2-12A

12

120

9.5

39200218H

7-2-18A

18

82

7.4

39200518H

16-2-18A

18

180

11.0

39200225H

7-2-25A

25

100

8.7

39200525H

16-2-25A

25

274

14.1

39200236H

7-2-36A

36

146

9.8

LSHF Braided Screened 16/0.2mm - 0.5mm2 39300502H

16-2-2C

2

71

6.5

39300202H

7-2-2C

2

25

3.8

39300503H

16-2-3C

3

82

6.8

39300203H

7-2-3C

3

29

4.0

39300504H

16-2-4C

4

97

7.3

39300204H

7-2-4C

4

33

4.3

39300506H

16-2-6C

6

130

8.3

39300206H

7-2-6C

6

57

5.6

39300508H

16-2-8C

8

152

8.8

39300208H

7-2-8C

8

66

6.2

39300512H

16-2-12C

12

202

10.5

39300212H

7-2-12C

12

87

6.9

39300518H

16-2-18C

18

270

12.0

39300218H

7-2-18C

18

115

8.4

39300525H

16-2-25C

25

350

14.1

39300225H

7-2-25C

25

153

9.5

39300536H

16-2-36C

36

475

16.1

39300236H

7-2-36C

36

207

10.7

LSHF Braided Screened 7/0.2mm - 0.22mm2

FS

0.5mm2 2.5amps

LSHF Foil Screened 7/0.2mm - 0.22mm2

LSHF Foil Screened 16/0.2mm - 0.5mm2 39400501PH 16-2-1PS 1 Pair

47

5.2

39400202H

7-2-2S

2

23

3.7

39400502PH 16-2-2PS 2 Pair

68

7.6

39400203H

7-2-3S

3

28

4.0

39400502H

16-2-2S

2

47

5.0

39400204H

7-2-4S

4

31

4.1

39400503H

16-2-3S

3

56

6.0

39400206H

7-2-6S

6

52

4.8

39400504H

16-2-4S

4

61

6.8

39400208H

7-2-8S

8

60

5.7

39400506H

16-2-6S

6

75

7.6

39400212H

7-2-12S

12

79

6.2

39400508H

16-2-8S

8

89

8.2

39400218H

7-2-18S

18

103

7.9

39400512H

16-2-12S

12

132

9.7

39400225H

7-2-25S

25

141

8.8

39400518H

16-2-18S

18

198

12.6

www.fscables.com

sales@fscables.com


91

SIGNAL & CONTROL Niltox® LF-316 LSHF LF-249 H05Z-K & H07Z-K (2491B & 6701B)

2491B and 6701B are flexible single cores with class 5 stranding conforming to the harmonisation standard H05Z-K and H07Z-K for Low Smoke Halogen Free single core cable. Applications include panel and conduit wiring where its flexibility makes installation easier. Public and government buildings are increasingly using LSHF cabling to reduce the risk of injury through smoke inhalation in the event of a fire. The cables also produce less corrosive gases when burnt, which is particularly important where sensitive electronic equipment is installed such as in computer rooms.

Construction

Technical Information

Plain fine copper wire strands to IEC 60228 class 5. Thermosetting insulation of Low Smoke Halogen Free compound to BS 7211.

Voltage Rating:

300/500V

Up to 1.0mm2

1.5mm2 and above 450/750V Temperature Rating:

-15°C to +90°C

Current Rating:

4E1A & B

Conductor Stranding:

To IEC 60228 Class 5.

Manufactured to:

BS 7211: 1994

Flame Retardant to:

IEC 60332-1-2

24901501

BASEC approval available on many from stock. If required, please check at time of enquiry. Part No.

Size mm2

No. of Strands/mm

Weight kg/km

O/D mm

249005xx

0.5

16/0.20

10

249007xx

0.75

24/0.20

13

2.4

249010xx

1.0

32/0.20

16

2.5

249015xx

1.5

30/0.25

21

2.9

249025xx

2.5

50/0.25

33

3.6

249040xx

4.0

56/0.30

49

4.2

249060xx

6.0

84/0.30

70

5.0

249100xx

10

80/0.40

125

6.4

249160xx

16

126/0.40

180

8.0

249250xx

25

196/0.40

275

9.5

249350xx

35

276/0.40

380

11.7

249500xx

50

400/0.40

560

12.4

249700xx

70

356/0.50

780

14.5

249950xx

95

485/0.50

1000

17.0

249120xx

120

614/0.50

1300

17.7

249150xx

150

765/0.50

1600

19.5

249185xx

185

944/0.50

2000

22.0

249240xx

240

1225/0.50

2600

2.1

24916099

FS

FS

FS

FS

FS

FS

25.3 cables

cables

FS

cables

FS

cables

To show the colour required please replace xx in the part number with: 04

White

08

Orange

Blue

05

Grey

09

Yellow

02

Brown

06

Violet

10

Green

03

Red

07

Pink

99

Green/Yellow

Standard pack size for conductor sizes up to and including 16mm2 is 100m, with some sizes/colours stocked on 500m reels. 25mm2 and above is normally stocked on bulk reels and can be cut to the length you require. Not all colours are available in the larger sizes.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

Black

01

cables

00

cables


92

SIGNAL & CONTROL SY PVC

SY PVC Steel Braided Multicore Where mechanical protection is called for on a flexible cable, SY is a popular choice. The tough, flexible, clear outer sheath provides excellent abrasion and oil resistance. Suitable as a supply or control cable for motors, plant, machinery and many other applications.

Construction

Technical Information

Fine copper wire strands to IEC 60228 Class 5.

Voltage Rating:

300/500V

Black PVC insulation with white numbers or colour

Temperature Rating:

Static -20°C to +80°C Flexing -5°C to +70°C

coded. Cables with more than 2 cores include a Bending Radius:

green/yellow earth, cores twisted together. Grey

Static 10 x cable diameter Flexing 20 x cable diameter

PVC inner sheath, steel wire braid, clear PVC outer Current Rating:

sheath. Part No.

11001504

cables

FS

FS cables

cables

FS

FS cables

Cores x mm²

Test 3000V

Weight kg/km

O/D mm

Number Coded 11000502 2 x 0.5 11000503 3 x 0.5 11000504 4 x 0.5 11000505 5 x 0.5 11000507 7 x 0.5 11000512 12 x 0.5 11000518 18 x 0.5 11000525 25 x 0.5 11000534 34 x 0.5 11000550 50 x 0.5

73 86 96 107 132 211 261 374 498 665

7.1 7.6 8.0 8.5 9.3 11.5 13.4 15.8 17.4 20.9

11000702 11000703 11000704 11000705 11000707 11000712 11000718 11000725 11000734 11000750

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 34 x 0.75 50 x 0.75

91 93 106 119 158 221 279 397 510 755

7.6 7.8 8.3 8.9 9.7 12.2 13.6 16.7 18.9 23.1

11001002 11001003 11001004 11001005 11001007 11001012 11001018 11001025 11001034 11001050

2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 34 x 1.0 50 x 1.0

96 104 109 127 152 238 326 479 579 848

8.2 8.4 8.8 9.3 9.9 12.5 14.5 17.9 19.3 22.1

www.fscables.com

Refer to IEE Regs Table 4F3A&B Part No.

Cores x mm²

Weight kg/km

O/D mm

11001502 11001503 11001504 11001505 11001507 11001512 11001518 11001525 11001542

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 25 x 1.5 42 x 1.5

102 122 146 158 214 321 464 625 959

8.5 8.7 9.3 9.9 12.4 13.7 16.8 19.8 23.4

11002502 11002503 11002504 11002505 11002507 11002512 11002518

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5

152 169 212 223 295 499 685

9.8 10.1 10.9 11.8 13.0 17.3 19.8

11004003 11004004 11004005 11004007

3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0

241 286 342 460

11.7 12.6 13.9 15.7

11006003 11006004 11006005 11006007

3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0

354 397 496 613

14.1 14.8 16.9 18.4

11010004 11010005 11010007

4 x 10 5 x 10 7 x 10

638 766 979

18.2 19.8 22.2

11016004 11016005 11025004 11025005 11035004 11050004 11070004 11095004

4 x 16 5 x 16 4 x 25 5 x 25 4 x 35 4 x 50 4 x 70 4 x 95

996 1159 1383 1758 1938 2689 3583 4935

21.8 23.5 25.3 28.9 29.7 34.9 44.8 47.8

sales@fscables.com


93

SY PVC SIGNAL & CONTROL Part No.

Cores x mm²

Weight kg/km

O/D mm

Colour Coded

Part No.

Cores x mm²

Weight kg/km

O/D mm

11006003C

3 x 6.0

549

14.7

11000702C

2 x 0.75

91

7.6

11006004E

4 x 6.0

583

15.9

11000703C

3 x 0.75

93

7.8

11006005E

5 x 6.0

674

17.4

11000704E

4 x 0.75

106

8.3

11006007C

7 x 6.0

853

19.1

11000705E

5 x 0.75

119

8.9

11000707C

7 x 0.75

181

12.6

11010003C

3 x 10

744

18.2

11000712C

12 x 0.75

284

12.7

11010004E

4 x 10

956

20.3

11010005E

5 x 10

1091

22.1

11001002C

2 x 1.0

96

8.2

11001003C

3 x 1.0

104

8.4

11016003C

3 x 16

1108

21.2

11001004E

4 x 1.0

109

8.8

11016004E

4 x 16

1395

23.2

11001005E

5 x 1.0

127

9.3

11016005E

5 x 16

1773

25.8

11001007E

7 x 1.0

342

10.8

11001012E

12 x 1.0

343

13.4

11025003C

3 x 25

1681

26.1

11025004E

4 x 25

2103

29.3

11025005E

5 x 25

2529

32.0

11001502C

2 x 1.5

102

8.5

11001503C

3 x 1.5

122

8.7

11001504E

4 x 1.5

146

9.3

11035003C

3 x 35

1973

31.9

11001505E

5 x 1.5

158

9.9

11035004E

4 x 35

2621

32.5

11001507C

7 x 1.5

286

12.7

11035005E

5 x 35

3268

36.2

11001512C

12 x 1.5

446

14.9 11050003C

3 x 50

2731

37.8

11002502C

2 x 2.5

152

9.8

11050004E

4 x 50

3613

38.5

11002503C

3 x 2.5

169

10.1

11050005E

5 x 50

4367

43.9

11002504E

4 x 2.5

212

10.9

11002505E

5 x 2.5

223

11.8

11070003C

3 x 70

2832

46.2

11002507C

7 x 2.5

427

15.4

11070004E

4 x 70

4893

47.4

11002512C

12 x 2.5

665

18.3

11070005E

5 x 70

11004003C

3 x 4.0

241

11.7

11095003C

3 x 95

11004004E

4 x 4.0

286

12.6

11095004E

11004005E

5 x 4.0

342

13.9

11095005E

11004007C

7 x 4.0

649

16.6 11120004E

4 x 120

49.1

4 x 95

6423

51.8

5 x 95

8162

56.5

8235

56.8

cables

4996

FS

cables

11150004E

4 x 150

10324

Blue

Brown

3 core

Blue

Brown

Green/Yellow

Tel: 01727 840 841

4 core

Blue

Black

5 core

Blue

Brown

Grey Black

Fax : 01727 840 842

Green/Yellow Grey

FS cables

63.2

FS

cables

cables

FS

Colour Code: 2 core

FS

52.5

cables

FS

5869

Green/Yellow

FS

cables

FS cables


94

SIGNAL & CONTROL CY PVC

CY PVC Bedded Screened Multicore N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Protecting signals from electromagnetic interference (EMI) or reducing electromagnetic radiation (EMR) from supply cables has substantially increased the need for screened multicore cables. Fine copper wire strands insulated with PVC and combined with pliable oil resistant PVC inner and outer sheaths ensure excellent flexibility, while the tinned copper wire braid forms an effective screen. Clear white numbering on black cores enable fast ‘right first time’ termination, vital when working with large numbers of cores or under artificial lighting which may distort core colours. CY has many uses including general wiring in machine tool applications especially in conjunction with PLC or microprocessor controlled manufacturing operations where signal interference could cause major problems. Also used as a supply cable where circumstances result in power and data cables being run in close proximity to each other. In these cases EMR can be significantly reduced. Construction

Technical Information

Fine copper wire strands to IEC 60228 Class 5. Black PVC

Voltage Rating:

300/500V

insulation with white numbers, a green/yellow earth

Temperature Rating:

Static -20°C to +80°C Flexing -5°C to +70°C

conductor in cables with more than 2 cores. (Colour coded versions also available). Cores twisted together. Grey PVC

Bending Radius:

inner sheath, tinned copper wire braid, clear PVC outer Current Rating:

sheath. Part No.

12001007

cables

FS

FS cables

cables

FS

FS cables

12000502 12000503 12000504 12000505 12000507 12000512 12000518 12000525 12000702 12000703 12000704 12000705 12000707 12000712 12000718 12000725 12001002 12001003 12001004 12001005 12001007 12001012 12001018 12001025 12001041

Test 3000V

Cores x mm²

Weight kg/km

O/D mm

2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 25 x 0.5 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 41 x 1.0

91 102 114 126 155 213 338 406 102 118 134 158 183 263 393 544 117 134 154 182 202 346 476 644 1008

6.8 7.4 7.9 8.6 9.2 11.6 13.4 15.5 7.2 7.7 8.3 8.9 9.7 12.1 15.3 16.8 7.6 8.1 8.6 9.7 10.5 13.4 15.6 18.1 22.1

www.fscables.com

Part No.

Static 10 x cable diameter Flexing 20 x cable diameter Refer to IEE Regs Table 4F3A&B

Cores x mm²

Weight kg/km

O/D mm

12001502

2 x 1.5

142

8.6

12001503

3 x 1.5

165

9.1

12001504

4 x 1.5

189

10.1

12001505

5 x 1.5

223

10.6

12001507

7 x 1.5

268

11.5

12001512

12 x 1.5

441

15.1

12001518

18 x 1.5

626

17.4

12002503

3 x 2.5

214

10.4

12002504

4 x 2.5

258

11.3

12002505

5 x 2.5

306

12.9

12002507

7 x 2.5

422

13.9

12004004

4 x 4.0

411

13.5

12004005

5 x 4.0

482

14.8

12006004

4 x 6.0

533

15.9

12006005

5 x 6.0

657

17.4

12010004

4 x 10

932

19.1

12010005

5 x 10

1085

22.6

12016004E

4 x 16

1195

22.3

12025004E

4 x 25

1918

32.5

12035004E

4 x 35

2516

35.6

12050004E

4 x 50

3374

38.7

12070004E

4 x 70

3819

43.8

12095004E

4 x 95

5859

47.9

12120004E

4 x 120

7351

58.2

sales@fscables.com


95

SIGNAL & CONTROL Equipment Wire LSHF Equipment Wire LSHF

The FSC range of LSHF equipment wire is intended for use with electronic equipment within public buildings, control panels, higher temperature applications, military and commercial data processing, in fact anywhere where the safety of people and property is essential.

Construction

Technical Information

Fine tinned copper wire strands, high performance LSHF insulation.

Voltage Rating:

600V AC

Temperature Rating:

-40°C to +120°C

Test 3000V AC

Minimum Bending Radius: 6 x Overall Diameter

Part No.

AWG

Stranding & mm

CSA mm2

249E3007xx

30

7/0.10

0.057

249E2807xx

28

7/0.13

0.089

249E2619xx

26

19/0.10

249E2419xx

24

249E2219xx 249E2216xx 249E2019xx

Weight kg/km

O/D mm

DC Resistance @ 20°C (Ohms/km)

0.9

0.70

355

1.2

0.78

225

0.155

1.9

0.88

135

19/0.13

0.241

2.7

1.00

85.9

22

19/0.16

0.382

4.0

1.16

53.1

-

16/0.20

0.50

5.2

1.28

40.1

20

19/0.20

0.597

6.2

1.36

32.4

249E2024xx

-

24/0.20

0.75

7.5

1.45

26.7

249E1819xx

18

19/0.25

0.963

9.5

1.60

20.4

249E1832xx

-

32/0.20

1.00

9.5

1.60

20.0

249E1619xx

16

19/0.29

1.229

12.0

1.36

15.7

249E1630xx

-

30/0.25

1.50

14.8

2.00

13.7

249E1419xx

14

19/0.36

1.870

18.5

2.21

10.0

249E1450xx

-

50/0.25

2.50

24.0

2.45

8.21

249E1237xx

12

37/0.32

2.976

29.0

2.74

6.62

Equipment Wire

Resistant to some oils, fuels and acids. Please check at time of order if critical. We are also able to offer LSHF equipment wire to Def-Stan 61-12 Part 18/5.

FS

cables

FS

FS

FS

FS

FS

cables

FS

cables

FS

cables

Versions that have both high (+200ºC) and lower (-60ºC) temperature ratings are also available. To show the colour required please replace xx in the part number with: 04

White

08

Orange

Blue

05

Grey

09

Yellow

02

Brown

06

Violet

10

Green

03

Red

07

Pink

99

Green/Yellow

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

Black

01

cables

00

cables


96

POWER Single Core Enhanced Circuit Integrity

Single Core Enhanced Circuit Integrity Designed for fixed installations where circuit integrity is critical in the event of a fire. The Low Smoke Halogen Free insulation also ensures minimal fumes and smoke are given off providing safety for both personnel and property. Maximum fire performance requires installation in either metal conduit or trunking.

Construction

Technical Information

Stranded plain copper conductor to IEC 60228 Class 2,

Voltage Rating:

0.6/1kV

mica glass tape, LSHF insulation.

Temperature Rating:

-40ºC to +90ºC

Minimum Bending Radius: 8 x cable diameter Flame Retardant:

IEC 60332-1-2, IEC 60332-3-24C

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2, EN 50267-2-1

Fire Resistant:

BS 6387 Categories CWZ (when applied to a single cable appropriately protected in steel conduit)

3871600199

Part No.

cables

FS

FS

Size mm²

No. of Strands/mm

Weight kg/km

Maximum O/D mm

Conductor Res @ 20°C Ohms/km

3871501xx

1.5

7/0.53

33

3.9

12.10

3872501xx

2.5

7/0.67

43

4.6

7.41

3874001xx

4.0

7/0.85

56

5.2

4.61

3876001xx

6.0

7/1.04

87

5.7

3.08

38710001xx

10

7/1.35

150

7.3

1.83

38716001xx

16

7/1.70

201

8.2

1.15

38725001xx

25

7/2.14

323

9.9

0.727

38735001xx

35

7/2.52

415

10.8

0.524

38750001xx

50

19/1.78

553

13.4

0.387

38770001xx

70

19/2.14

776

15.3

0.268

38795001xx

95

19/2.52

1149

17.8

0.193

38712001xx

120

37/2.03

1426

19.3

0.153

38715001xx

150

37/2.25

1731

21.5

0.124

38718501xx

185

37/2.52

2158

23.8

0.0991

38724001xx

240

61/2.25

2931

26.8

0.0754

38730001xx

300

61/2.52

3549

29.8

0.0601

cables

Some sizes and colours are also LPCB approved. If you need this please state at time of enquiry. To show the colour required please replace xx in the part number with: cables

FS

FS cables

00

Black

04

White

08

Orange

01

Blue

05

Grey

09

Yellow

02

Brown

06

Violet

10

Green

03

Red

07

Pink

99

Green/Yellow

www.fscables.com

sales@fscables.com


97

BS 5467 Armoured POWER BS 5467 Armoured PVC Power Cables - 0.6/1kV

BS 5467 cables are used for mains or low voltage power and control circuits. They offer excellent mechanical protection from damage through the use of a heavy galvanised steel wire armour. The GSWA armour and black UV stable water resistant PVC jacket makes them suitable for use inside and outside buildings or for direct burial in the ground.

Construction

Technical Information

Plain copper conductors to IEC 60228 class 2 (stranded), XLPE

Voltage Rating:

insulation, PVC inner sheath, galvanised steel wire armour,

Conductor Stranding: IEC 60228 class 2 shaped or circular

PVC sheath – black.

Temperature Rating:

Core Identification

Bending Radius :

1.5mm² to 16mm²: 6 x overall diameter

2 Core

Brown, blue

Flame Retardant:

IEC 60332-1-2

3 Core

Brown, black, grey

Manufactured To:

BS 5467 / BS 60502

4 Core

Brown, black, grey, blue

5 Core

Brown, black, grey, blue, green/yellow

0.6/1kV -15°C to +90°C max conductor temperature

If a Low Smoke Halogen Free (LSHF) version is required please

7 Core and above, including all sizes of auxiliary cables - White cores with black numbering

Part No.

Cores x mm²

as BS6436, please call for details. Weight kg/km

12.3 12.8 13.5 15.1 15.1 15.9 13.6 14.1 15.0 17.1 17.1 16.3 14.7 15.3 16.4 19.7 19.7 19.7 15.9 16.6 18.7 19.6 cables 18.0 20.0 21.1 20.0 22.0 22.9

54600103E

FS

FS

FS

FS

FS

FS

FS

FS

cables

cables

7.7 8.2 8.9 10.6 10.6 10.9 9.0 9.5 10.4 12.5 12.5 12.1 10.1 10.7 11.8 14.2 14.2 13.9 11.3 11.5 13.2 14.0 13.2 13.9 15.6 14.5 15.8 17.2

O/D mm

cables

305 338 381 426 426 490 352 397 452 549 549 600 419 481 563 810 810 950 498 569 795 865 764 869 1064 900 1159 1410

Dia. over bedding

cables

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 5 x 1.5 7 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 5 x 2.5 7 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 5 x 4.0 5 x 4.0 7 x 4.0 2 x 6.0 3 x 6.0 4 x 6.0 5 x 6.0 2 x 10* 3 x 10* 4 x 10* 2 x 16* 3 x 16* 4 x 16*

A version with PVC insulation and PVC sheath is also available

cables

54600102E 54600103E 54600104E 54600105E 54600105AUX 54600107 54600202E 54600203E 54600204E 54600205E 54600205AUX 54600207 54600402E 54600403E 54600404E 54600405E 54600405AUX 54600407 54600602E 54600603E 54600604E 54600605E 54601002E 54601003E 54601004E 54601602E 54601603E 54601604E

use BS6724 which can be found on page 98.

*Circular or compacted circular stranded conductors (class 2) Weights and dimensions will vary from manufacturer, if critical please check at time of order. Other conductor sizes and core counts available upon request

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


98

POWER BS 6724 Armoured LSHF

BS 6724 Armoured LSHF Power – 0.6/1kV BS 6724 mains voltage armoured power and control cables are manufactured using Low Smoke Halogen Free compounds. This makes them ideal for use in public buildings, tunnels and areas of increased safety such as refineries and power stations where mechanical damage and fire risk is a concern.

Construction

Technical Information

Plain copper conductors to IEC 60228 class 2, XLPE insulation,

Voltage Rating: 0.6/1kV Conductor Stranding: IEC 60228 class 2 shaped or circular Temperature Rating: -15°C to +90°C maximum conductor temperature Bending Radius: 1.5mm² to 16mm²: 6 x overall diameter Flame Retardant: IEC 60332-1-2, IEC 60332-3-24 cat C Smoke Emission: IEC 61034-2, BS EN 50268 Halogen Emission: IEC 60754-2, BS EN 50267 Manufactured To: BS 6724 / IEC 60502

LSHF bedding, galvanised steel wire armour, black LSHF Sheath. Core Identification 2 Core

Brown, blue

3 Core

Brown, black, grey

4 Core

Brown, black, grey, blue

5 Core Brown, black, grey, blue, green/yellow 7 Core and above, including all sizes of auxiliary cables White cores with black numbering

Part No.

72400604E

cables

FS

FS cables

cables

FS

FS cables

72400102E 72400103E 72400104E 72400105E 72400105AUX 72400107 72400202E 72400203E 72400204E 72400205E 72400205AUX 72400207 72400402E 72400403E 72400404E 72400405E 72400405AUX 72400407 72400602E 72400603E 72400604E 72400605E 72401002E 72401003E 72401004E 72401005E 72401602E 72401603E 72401604E

Cores x mm²

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 5 x 1.5 7 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 5 x 2.5 7 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 5 x 4.0 5 x 4.0 7 x 4.0 2 x 6.0 3 x 6.0 4 x 6.0 5 x 6.0 2 x 10* 3 x 10* 4 x 10* 5 x 10* 2 x 16* 3 x 16* 4 x 16*

We are also able to supply fire resistant versions such as Prysmian FP 400, Draka Firetuf power and Nexans NX 400. Please specify sizes and quantity and if you require a specific manufacturer. Weight kg/km

305 338 381 426 426 490 352 397 452 549 549 600 419 481 563 810 810 950 498 639 795 865 764 908 1064 1222 900 1220 1410

Dia. over bedding

O/D mm

7.7 8.2 8.9 10.6 10.6 10.9 9.0 9.5 10.4 12.5 12.5 12.1 10.1 10.7 11.8 14.2 14.2 13.9 11.3 12.0 13.2 14.0 13.2 14.0 15.6 17.1 14.5 15.5 17.2

12.3 12.8 13.5 15.1 15.1 15.9 13.6 14.1 15.0 17.1 17.1 16.3 14.7 15.3 16.4 19.7 19.7 19.7 15.9 16.6 18.7 19.6 18.0 19.5 21.1 22.5 20.0 21.2 22.9

*Circular or compacted circular stranded conductors (class 2) Weights and dimensions will vary from manufacturer, if critical please check at time of order. Other conductor sizes and core counts are available upon request

www.fscables.com

sales@fscables.com


99

Safe-T-Shield POWER Safe-T-Shield N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

Safe-T-Shield Low Smoke Halogen Free cable offers substantial advantages over conventional wiring methods. It is ideal for fixed wiring in hospitals, airports, computer rooms and other sensitive environments. The high level of screening ensures substantially reduced levels of electromagnetic interference (EMI) making it the right choice where electromagnetic capability (EMC) is a priority. Safe-T-Shield is manufactured and tested to the performance criteria of BS 8436. Because it is faster to install and lighter than small armoured cables or conduit, cost savings of up to 40% can be achieved. If the cable is pierced or accidentally cut the aluminium screen and CPC minimise the chance of personal injury. This cable is an alternative to Multi-Plus and we are also able to supply Prysmian LSX® Brand. Construction

Technical Information

Plain copper wire strands to IEC 60228 class 2, Halogen Free

Voltage Rating:

0.6/1kV

XLPE insulation to BS 6899, full size tinned copper earth

Temperature Rating:

-10°C to +90°C

conductor to IEC 60228 class 2, longitudinal aluminium tape,

Sheath Colour:

Low Smoke Halogen Free sheath to BS EN 50267-2-1 & BS EN 61034-2.

Part No.

38801502E

Cores x mm²

2 E 1.5

Conductor Stranding/mm

7/0.53

White, other colours on request All cables have a full size bare earth or CPC.

Current Rating:

Refer to IEE Regs table 4E2A

Flame Retardant:

IEC 60332-1-2

Smoke Emission:

IEC 61034-2

Halogen Emission:

IEC 60754-1 & 2

Weight kg/km

O/D mm

105

9.8

38801503E

3 E 1.5

7/0.53

140

10.3

38801504E

4 E 1.5

7/0.53

160

11.2

38802502E

2 E 2.5

7/0.67

137

10.6

38802503E

3 E 2.5

7/0.67

184

11.1

38802504E

4 E 2.5

7/0.67

258

12.9

7/0.85

209

11.3

7/0.85

267

13.1

38804004E

4 E 4.0

7/0.85

320

14.2

38806002E

2 E 6.0

7/1.04

260

13.2

38806003E

3 E 6.0

7/1.04

330

14.2

38806004E

4 E 6.0

7/1.04

455

14.9

FS

FS

FS

cables

FS

FS

FS

FS

FS

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Standard pack size 100m or 500m. Large sizes can be cut to the length required. Available in black in some sizes, please put B after the part number when ordering. A 300/500V grade, Safe-T-Shield Lite is also available.

cables

2 E 4.0 3 E 4.0

cables

38804002E 38804003E

38802502E

cables


100

POWER NYY

NYY: PVC/PVC Unarmoured PowerScreened, – 0.6/1kV Fire Resistant (IEC 60331) N2XCH-FE180/E90: XLPE/Cu/LSHF LSHF Power Cable – 0.6/1kV

NYY cables are an economical solution to power and control wiring where mechanical protection is not required. Used both indoor and outdoor these cables are suitable for direct burial or through ducts, local regulations permitting. Originating in Germany they are now popular in many parts of the world where cost, weight and size savings through not having an armour can offer many benefits. They are also easy to gland and terminate and require less containment. Construction

Technical Information

Plain copper wire conductors to IEC 60228 class 1 or 2, PVC

Voltage Rating:

insulation, bedding compound, PVC sheath – black.

Conductor Stranding: ≤ 16 mm² solid. IEC 60228 class 1

0.6/1kV

Temperature Rating:

-30°C to +70°C fixed -5°C to +70°C for installation

Bending Radius:

Single core 15 x overall diameter Multi core 12 x overall diameter

Flame Retardant:

VDE 0472 test B, IEC 60332-1-2, EN 50265-2-1

Manufactured To:

VDE 0276 pt 603 up to 5 core, pt 627 for 7 core & above, IEC 60502

NYY can be supplied with a green/yellow earth conductor reference NYY-J or without an earth conductor – reference NYY-O. Core Identification Type

NYY-J with protective earth

1 Core

Green/yellow

Black

2 Core

-

Brown, blue

3 Core

Brown, blue, G/Y earth

Brown, black, grey

4 Core

Brown, black, grey, G/Y earth

Brown, black, grey, blue

NYY-O without protective earth

5 Core

Brown, black, grey, blue, G/Y earth

Black, blue, brown, grey, black

7 Core and above

Number coded with a G/Y earth

Number coded

FS -

cables

Part No. NYY-J

Part No. NYY-O

Cores x mm²

Weight kg/km

O/D mm

N0100102E

2 x 1.5

165

11.0

N0100103E

N0100103

3 x 1.5

185

12.5

N0100104E

N0100104

4 x 1.5

220

13.0

N0100105E

N0100105

5 x 1.5

275

13.5

N0100107E

N0100107

7 x 1.5

355

15.0

N0100110E

N0100110

10 x 1.5

525

18.5

N0100112

12 x 1.5

565

19.0

N0100114E

N0100114

14 x 1.5

615

20.5

N0100116E

N0100116

16 x 1.5

695

20.5

N0100119E

N0100119

19 x 1.5

755

21.5

-

N0100121

21 x 1.5

825

21.5

N0100124E

N0100124

24 x 1.5

945

24.5

N0100130E

N0100130

30 x 1.5

1105

25.5

FS

cables N0100112E

cables

FS

FS cables

www.fscables.com

sales@fscables.com


101

NYY POWER Part No. NYY-J

Part No. NYY-O

Cores x mm²

Weight kg/km

O/D mm

2 x 2.5

210

12.0

N0100203

3 x 2.5

235

13.0

N0100204E

N0100204

4 x 2.5

285

13.5

N0100205E

N0100205

5 x 2.5

350

14.5

N0100207E

-

7 x 2.5

445

16.0

N0100210E

-

10 x 2.5

625

20.0

N0100212E

-

12 x 2.5

675

20.5

N0100214E

-

14 x 2.5

785

21.0

N0100216E

-

16 x 2.5

865

22.5

N0100219E

-

19 x 2.5

920

23.0

N0100221E

-

21 x 2.5

1045

23.5

N0100224E

-

24 x 2.5

1395

26.0

N0100230E

-

30 x 2.5

1445

28.5

N0100401E

N0100401

1 x 4.0

100

9.0

-

N0100402E

2 x 4.0

295

14.0

N0100403E

N0100403

3 x 4.0

325

16.0

N0100404E

N0100404

4 x 4.0

395

17.0

N0100405E

N0100405

5 x 4.0

475

18.0

N0100601E

N0100601

1 x 6.0

125

9.5

-

N0100602E

2 x 6.0

355

15.5

N0100603E

N0100603

3 x 6.0

420

16.0

N0100604E

N0100604

4 x 6.0

515

18.5

N0100605E

N0100605

5 x 6.0

615

19.5

N0101001

N0101001

1 x 10

185

9.5

-

N0101002E

2 x 10

490

16.5

N0101003

N0101003

3 x 10

585

18.0

N0101004

N0101004

4 x 10

725

20.0

N0101005

N0101005

5 x 10

885

21.5

N0101601E

N0101601

1 x 16

245

10.0

-

N0101602E

2 x 16

665

19.0

N0101603E

N0101603

3 x 16

810

20.5

N0101604E

N0101604

4 x 16

1055

22.0

N0101605E

N0101605

5 x 16

1250

N0100604E

FS

FS

FS

FS

FS

FS

FS

FS

24.0 cables

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

cables

cables

Larger sizes up to 630mm² can be supplied cut to length on short lead-times, please call us with your specific requirement.

cables

N0100202E

N0100203E

cables

-

cables


102

MOG BS 6883 0.6/1kV Shipwiring Power

N2XCH-FE180/E90: XLPE/Cu/LSHF BS 6883 0.6/1kV Shipwiring PowerScreened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Originally designed for wiring ships, BS 6883 cables have been widely adopted in other marine installations including oil rigs and platforms. They are available in single and multi core versions both unarmoured (type 657 SW4) and with a galvanized steel wire braid armour (type 658 SW4) for mechanical protection. Construction

Technical Information

657 SW4 Unarmoured

Voltage Rating:

0.6/1kV

Tinned stranded copper conductor, EPR insulation, SW4 LSHF

Conductor Stranding:

IEC 60228 Class 2, tinned copper

elastomeric outer sheath – black.

Temperature Rating:

-30°C to +85°C

Bending Radius Static:

657 SW4

658 SW4

≤ 10mm2

3 x cable OD

4 x cable OD

658 SW4 Armoured Tinned stranded copper conductor, EPR insulation, Halogen Free elastomeric bedding, galvanized steel wire braid armour, SW4 LSHF elastomeric outer sheath - black.

>10mm2 to 25mm2

4 x cable OD

4 x cable OD

> 25mm2

6 x cable OD

6 x cable OD

Oxygen Index of Sheath: >31%

Core Identification

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission:

IEC 61034-1 & 2, BS 7622

White cores with black numbers. Colour coded cores available to order. Halogen Emission: Manufactured To:

Part No.

65702512H

cables

FS

FS cables

cables

FS

FS cables

Cores x mm²

Weight kg/km

BS6883 657 SW4 Unarmoured 65701501H 1 x 1.5 42 65701502H 2 x 1.5 105 65701503H 3 x 1.5 130 65701504H 4 x 1.5 155 65701507H 7 x 1.5 260 65701512H 12 x 1.5 405 65701519H 19 x 1.5 590 65701527H 27 x 1.5 820 65702501H 1 x 2.5 57 65702502H 2 x 2.5 145 65702503H 3 x 2.5 180 65702504H 4 x 2.5 215 65702507H 7 x 2.5 365 65702512H 12 x 2.5 585 65702519H 19 x 2.5 860 65704001H 1 x 4.0 82 65704002H 2 x 4.0 225 65704003H 3 x 4.0 270 65704004H 4 x 4.0 355 65706001H 1 x 6.0 105 65706002H 2 x 6.0 285 65706003H 3 x 6.0 350 65706004H 4 x 6.0 445 65710001H 1 x 10 165 65710002H 2 x 10 445 65710003H 3 x 10 565 65710004H 4 x 10 700

O/D mm

6.0 8.5 9.0 10.0 12.0 15.5 19.0 22.0 6.0 9.5 10.0 11.0 13.0 18.0 21.0 7.0 11.5 12.0 13.0 7.0 13.0 13.5 14.5 8.0 14.5 15.5 17.0

www.fscables.com

Part No.

IEC 60754-1 & 2, BS 6425-1 BS 6883/UKOOA

Cores x mm²

Weight kg/km

65716001H

1 x 16

230

9.5

65716002H

2 x 16

630

17.0

65716003H

3 x 16

795

18.0

65716004H

4 x 16

1010

20.0

65725001H

1 x 25

360

12.0

65725002H

2 x 25

965

21.0

65725003H

3 x 25

1240

22.0

65725004H

4 x 25

1570

25.5

65735001H

1 x 35

425

12.5

65735002H

2 x 35

1140

23.0

65735003H

3 x 35

1480

25.0

65735004H

4 x 35

1880

27.0

65750001H

1 x 50

570

14.0

65750002H

2 x 50

1520

26.0

65750003H

3 x 50

1960

28.5

65750004H

4 x 50

2510

32.0

65770001H

1 x 70

785

16.0

65770002H

2 x 70

2070

31.0

65770003H

3 x 70

2700

33.0

65770004H

4 x 70

3490

36.0

65795001H

1 x 95

1060

18.0

65795003H

3 x 95

3680

37.0

65795004H

4 x 95

4780

42.0

65712001H

1 x 120

1300

21.0

65712003H

3 x 120

4490

42.0

65712004H

4 x 120

5830

46.0

sales@fscables.com

O/D mm


BS 6883 0.6/1kV Shipwiring Power MOG Part No.

Cores x mm²

280 310 390 570 780 1080 1430 320 400 460 650 980 1350 1810 420 505 590 510 595 700 680 780 935 960 1120 1370 1250 1500 1850 1455 1950 2380 2160 2640 3300 2930 3630 4340 4720 5830 5820 7180

10.0 10.5 11.5 14.0 18.5 22.0 26.5 11.0 11.5 12.5 15.0 20.0 24.0 29.5 12.0 13.0 14.0 13.0 14.0 15.5 15.0 16.0 18.0 17.5 18.5 20.5 21.0 22.5 25.0 23.5 25.0 28.0 27.0 29.0 32.5 31.0 33.0 37.0 38.0 42.5 41.0 46.0

BS6883 658 SW4 Armoured 65801502H 2 x 1.5 65801503H 3 x 1.5 65801504H 4 x 1.5 65801507H 7 x 1.5 65801512H 12 x 1.5 65801519H 19 x 1.5 65801527H 27 x 1.5 65802502H 2 x 2.5 65802503H 3 x 2.5 65802504H 4 x 2.5 65802507H 7 x 2.5 65802512H 12 x 2.5 65802519H 19 x 2.5 65802527H 27 x 2.5 65804002H 2 x 4.0 65804003H 3 x 4.0 65804004H 4 x 4.0 65806002H 2 x 6.0 65806003H 3 x 6.0 65806004H 4 x 6.0 65810002H 2 x 10 65810003H 3 x 10 65810004H 4 x 10 65816002H 2 x 16 65816003H 3 x 16 65816004H 4 x 16 65825002H 2 x 25 65825003H 3 x 25 65825004H 4 x 25 65835002H 2 x 35 65835003H 3 x 35 65835004H 4 x 35 65850002H 2 x 50 65850003H 3 x 50 65850004H 4 x 50 65870002H 2 x 70 65870003H 3 x 70 65870004H 4 x 70 65895003H 3 x 95 65895004H 4 x 95 65812003H 3 x 120 65812004H 4 x 120

O/D mm

13.5 14.5 16.5 18.0 23.5 27.5 32.0 14.5 16.0 17.0 20.0 25.0 29.0 34.5 16.5 17.0 19.0 18.0 18.5 20.0 20.0 20.5 23.0 23.0 24.0 26.0 26.0 27.5 30.0 28.0 30.0 33.5 32.5 34.0 38.5 37.0 39.0 43.0 44.0 cables 49.0 48.5 54.0

FS

FS

FS

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

65802512H

cables

Dia. over Bedding mm

cables

Weight kg/km

103

cables


104

MOG BS 6883 657-SW4 Shipwiring Instrumentation

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) BS 6883 657-SW4 Unarmoured Shipwiring Instrumentation LSHF Power Cable – 0.6/1kV Manufactured in both pairs and triples these 150/250V marine instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or where difficult routing is necessary these cables are ideal where no additional mechanical protection is required. Using SW4 Low Smoke Halogen Free sheathing compounds ensures that in the event of a fire the cable offers excellent protection to both people and property by not emitting toxic or corrosive gases.

Construction

Electrical Characteristics

Collectively Screened

Conductor Size:

0.75mm²

1.5mm²

Tinned copper wire conductors to IEC 60228 class 2, EPR

Conductor Resistance:

<24.5 Ohms/km

<12.1 Ohms/km

insulation, cores twisted into pairs or triples, overall foil screen

Insulation Resistance:

940 MOhm x km

730 MOhm x km

and drain wire, SW4 oil resistant LSHF sheath - grey, blue or

Mutual Capacitance @ 800Hz:

black.

Individual Screen:

90nF/km

110nF/km

Collective Screen:

80nF/km

90nF/km

Individually Screened Tinned copper wire conductors to IEC 60228 class 2, EPR

Technical Information

insulation, cores twisted into pairs or triples, each pair or triple aluminum foil screened with a drain wire, SW4 oil

Voltage Rating:

150/250V

Conductor Stranding:

IEC 60228 Class 2,

resistant LSHF sheath – grey, blue or black.

tinned copper conductors

Class 5 conductors to IEC 60228 can be supplied on request.

Temperature Rating:

-30°C to +85°C

Bending Radius Static:

8 x overall diameter

Oxygen Index of Sheath: >31%

Core Identification

Flame Retardant:

Pairs - Black & white

IEC 60332-1-2, IEC 60332-3-22 Cat A, BS 4066-3

Triples - Black, white & red

Smoke Emission:

IEC 61034-1 & 2, BS 7622

Each pair is identified by a numbered tape or printed

Halogen Emission:

IEC 60754-1 & 2, BS 6425-1

numbers on the cores.

Oil Resistant:

BS 7655 SW4 section 2.6

Manufactured To:

BS 6883/UKOOA

Part No. cables

FS

Pairs Collectively Screened 657C0702PHxx 657C0703PHxx 657C0707PHxx 657C0712PHxx 657C0719PHxx 657C0720PHxx 657C0727PHxx

FS cables

657C1502PHxx 657C1503PHxx 657C1507PHxx 657C1512PHxx 657C1520PHxx 657C1527PHxx cables

FS

FS cables

No. of Pairs

mm2

Weight kg/km

O/D mm

2 3 7 12 19 20 27

0.75 0.75 0.75 0.75 0.75 0.75 0.75

180 210 380 610 875 975 1210

12.5 13.0 18.0 23.5 27.0 28.5 32.5

2 3 7 12 20 27

1.5 1.5 1.5 1.5 1.5 1.5

271 310 601 900 1310 1780

14.0 15.8 20.0 26.0 30.5 32.5

www.fscables.com

sales@fscables.com


BS 6883 657-SW4 Shipwiring Instrumentation MOG Part No.

mm2

Weight kg/km

O/D mm

1 2 3 7 12 20 27

0.75 0.75 0.75 0.75 0.75 0.75 0.75

95 165 260 480 750 1150 1600

8.1 12.0 13.0 18.5 22.5 28.0 31.5

1 2 3 7 12 20

1.5 1.5 1.5 1.5 1.5 1.5

135 254 300 690 1110 1850

16.5 14.3 15.0 21.0 27.0 34.5

mm2

Weight kg/km

O/D mm

0.75 0.75 0.75

260 501 805

15.0 20.5 25.0

1.5 1.5 1.5

350 790 1250

15.5 23.4 28.5

0.75 0.75 0.75 0.75

110 300 580 971

8.5 15.0 19.5 25.0

1.5 1.5 1.5 1.5

165 410 900 1500

9.5 17.5 25.0 28.5

No. of Pairs

Pairs Individually Screened 657I0701PHxx 657I0702PHxx 657I0703PHxx 657I0707PHxx 657I0712PHxx 657I0720PHxx 657I0727PHxx 658I1501PHxx 658I1502PHxx 657I1503PHxx 657I1507PHxx 657I1512PHxx 657I1520PHxx Part No.

No. of Triples

Triples Collectively Screened 657C0703THxx 3 657C0707THxx 7 657C0712THxx 12 657C1503THxx 657C1507THxx 657C1512THxx

3 7 12

Triples Individually Screened 657I0701THxx 1 657I0703THxx 3 657I0707THxx 7 657I0712THxx 12

To show the colour required please replace xx in the part number with: 05

Grey

01

Blue

00

Black

FS

FS

FS

cables

FS

FS

FS

FS

FS

cables

1 3 7 12

657C0707PH00

cables

657I1501THxx 657I1503THxx 657I1507THxx 657I1512THxx

105

cables

Other pair and triple configurations available on request

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables


106

MOG BS 6883 658-SW4 Shipwiring Instrumentation

N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) BS 6883 658-SW4 Armoured Shipwiring Instrumentation LSHF Power Cable – 0.6/1kV Similar in construction to the BS 6883 657 SW4 instrumentation types, these cables have an additional steel wire braid armour for mechanical protection. Manufactured in both pairs and triples these 150/250V marine instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. They maintain good flexibility for installation on ships and oil rigs. The SW4 Low Smoke Halogen Free sheathing is oil resistant and ensures that in the event of a fire the cable will offer excellent protection to both people and property by not emitting toxic or corrosive gases.

Construction

Electrical Characteristics

Collectively Screened

Conductor Size:

0.75mm²

1.5mm²

Tinned copper wire conductors to IEC 60228 class 2, EPR

Conductor Resistance:

<24.5 Ohms/km

<12.1 Ohms/km

insulation, cores twisted into pairs or triples, overall foil screen

Insulation Resistance:

940 MOhm x km

730 MOhm x km

and drain wire, LSHF bedding, galvanised steel wire braid,

Mutual Capacitance @ 800Hz:

SW4 oil resistant LSHF sheath - grey, blue or black.

Individual Screen:

90nF/km

110nF/km

Collective Screen:

80nF/km

90nF/km

Class 5 conductors to IEC 60228 can be supplied on request. Individually Screened

Technical Information

Tinned copper wire conductors to IEC 60228 class 2, EPR

Voltage Rating:

150/250V

insulation, cores twisted into pairs or triples, each pair or

Conductor Stranding:

IEC 60228 Class 2,

triple aluminum foil screened with a drain wire, LSHF

tinned copper conductors

bedding, galvanised steel wire braid, SW4 oil resistant LSHF

Temperature Rating:

-30°C to +85°C

sheath – grey, blue or black.

Bending Radius Static:

8 x overall diameter

Oxygen Index of Sheath: >31% Core Identification

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-22 Cat A

Pairs - Black & white

Smoke Emission:

IEC 61034-1 & 2, BS 7622

Triples - Black, white & red

Halogen Emission:

IEC 60754-1 & 2, BS 6425-1

Oil Resistant:

BS 7655 SW4 section 2.6

Manufactured To:

BS 6883/UKOOA

Each pair is identified by a numbered tape or printed numbers on the cores. Part No.

No. of Pairs

Pairs Collectively Screened 658C0702PHxx 2 658C0703PHxx 3 658C0707PHxx 7 658C0712PHxx 12 658C0719PHxx 19 658C0720PHxx 20 658C0727PHxx 27 cables

FS

FS cables

658C1502PHxx 658C1503PHxx 658C1507PHxx 658C1512PHxx 658C1520PHxx 658C1527PHxx cables

FS

FS cables

2 3 7 12 20 27

Size mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

0.75 0.75 0.75 0.75 0.75 0.75 0.75

379 420 660 1010 1460 1570 1980

13.5 12.0 16.5 21.5 24.5 25.5 29.0

15.5 16.5 21.0 26.0 29.5 31.5 35.5

1.5 1.5 1.5 1.5 1.5 1.5

477 520 821 1291 2130 2650

14.0 15.0 18.5 24.5 29.0 33.5

17.5 18.5 23.0 30.0 35.5 40.0

www.fscables.com

sales@fscables.com


BS 6883 658-SW4 Shipwiring Instrumentation MOG Part No.

No. of Pairs

Pairs Individually Screened 658I0701PHxx 1 658I0702PHxx 2 658I0703PHxx 3 658I0707PHxx 7 658I0712PHxx 12 658I0720PHxx 20

Weight kg/km

Dia. over Bedding mm

230 420 530 721 1111 1701

7.5 11.0 12.0 16.5 22.0 26.0

11.5 17.0 18.5 21.0 27.0 34.5

1 2 3 7 12 20

1.5 1.5 1.5 1.5 1.5 1.5

290 511 560 980 1670 2430

8.5 13.0 14.0 20.0 25.0 31.5

12.5 18.0 19.0 26.0 32.0 38.0

No. of Triples

Size mm²

Triples Collectively Screened 658C0703THxx 3 658C0707THxx 7 658C0712THxx 12 658C1503THxx 3 658C1507THxx 7 658C1512THxx 12 Triples Individually Screened 658I0701THxx 1 658I0703THxx 3 658I0707THxx 7 658I0712THxx 12

Dia. over Bedding mm

0.75 0.75 0.75

510 820 1290

13.5 18.0 24.0

18.0 22.5 29.0

1.5 1.5 1.5

520 1280 1840

14.5 20.5 27.5

19.5 26.5 33.5

0.75 0.75 0.75 0.75

245 530 898 1530

8.0 14.0 18.5 25.0

12.0 18.5 23.5 31.0

1.5 1.5 1.5 1.5

320 690 1390 2105

9.0 15.5 23.0 29.5

13.0 20.5 27.5 34.5

To show the colour required please replace xx in the part number with: Grey

01

Blue

O/D mm

00

Black

Other pair and triple configurations available on request

FS

FS

FS

cables

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

1 3 7 12

Weight kg/km

658C0707PH05

cables

658I1501THxx 658I1503THxx 658I1507THxx 658I1512THxx

05

O/D mm

0.75 0.75 0.75 0.75 0.75 0.75

658I1501PHxx 658I1502PHxx 658I1503PHxx 658I1507PHxx 658I1512PHxx 658I1520PHxx

Part No.

Size mm²

107

cables


108

MOG BS 7917 0.6/1kV Shipwiring Power

BS 7917 0.6/1kV Shipwiring PowerScreened, – Fire Resistant N2XCH-FE180/E90: XLPE/Cu/LSHF Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Used widely on ships, oil rigs, platforms and refineries where fire resistance to IEC 60331 is vital. BS 7917 cables provide circuit integrity to maintain essential services in the event of a fire. The 657M SW4 unarmoured versions are ideal for applications where small bending radii are required. When mechanical protection is needed the 658M SW4 steel braid armour (GSWB) version provides the solution whilst maintaining good flexibility for installation in restricted areas. Construction

Technical Information

657M SW4 Unarmoured

Voltage Rating:

0.6/1kV

Stranded tinned copper conductor, mica glass tape fire barrier,

Conductor Stranding:

IEC 60228 Class 2, tinned copper

EPR insulation, SW4 LSHF elastomeric outer sheath – black.

Temperature Rating:

-30°C to +85°C

Single core cables are available in green/yellow for earthing

Bending Radius Static:

657M SW4

658M SW4

applications.

≤ 10mm2

3 x cable OD

4 x cable OD

>10mm2 to 25mm2

4 x cable OD

4 x cable OD

> 25mm2

6 x cable OD

6 x cable OD

658M SW4 Armoured Stranded tinned copper conductor, mica glass tape fire barrier, EPR insulation, halogen free thermoplastic elastomeric bedding, galvanized steel wire braid armour, SW4 LSHF elastomeric outer sheath - black. Core Identification White cores with black numbers. Colour coded cores available to order. Part No.

Cores x mm²

Weight kg/km

Oxygen Index of Sheath: >31% Fire Resistant:

IEC 60331-21

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission:

IEC 61034-1 & 2, BS 7622

Halogen Emission:

IEC 60754-1 & 2, BS 6425-1

Manufactured To:

BS 7917 / BS 6883

O/D mm

BS 7917 657M SW4 Unarmoured 65701512HM

cables

FS

FS cables

cables

FS

FS cables

Part No.

Cores x mm²

Weight kg/km

O/D mm

65706003HM

3 x 6.0

350

13.5

65701501HM

1 x 1.5

42

6.0

65706004HM

4 x 6.0

445

14.5

65701502HM

2 x 1.5

105

8.5

65710001HM

1 x 10

165

8.0

65701503HM

3 x 1.5

130

9.0

65710002HM

2 x 10

445

14.5

65701504HM

4 x 1.5

155

10.0

65710003HM

3 x 10

565

15.5

65701507HM

7 x 1.5

260

12.0

65710004HM

4 x 10

700

17.0

65701512HM

12 x 1.5

405

15.5

65716001HM

1 x 16

230

9.5

65701519HM

19 x 1.5

590

19.0

65716002HM

2 x 16

630

17.0

65701527HM

27 x 1.5

820

22.0

65716003HM

3 x 16

795

18.0

65702501HM

1 x 2.5

57

6.0

65716004HM

4 x 16

1010

20.0

65702502HM

2 x 2.5

145

9.5

65725001HM

1 x 25

360

12.0

65702503HM

3 x 2.5

180

10.0

65725002HM

2 x 25

965

21.0

65702504HM

4 x 2.5

215

11.0

65725003HM

3 x 25

1240

22.0

65702507HM

7 x 2.5

365

13.0

65725004HM

4 x 25

1570

25.5

65702512HM

12 x 2.5

585

18.0

65735001HM

1 x 35

425

12.5

65702519HM

19 x 2.5

860

21.0

65735002HM

2 x 35

1140

23.0

65704001HM

1 x 4.0

82

7.0

65735003HM

3 x 35

1480

25.0

65704002HM

2 x 4.0

225

11.5

65735004HM

4 x 35

1880

27.0

65704003HM

3 x 4.0

270

12.0

65750001HM

1 x 50

570

14.0

65704004HM

4 x 4.0

355

13.0

65750002HM

2 x 50

1520

26.0

65706001HM

1 x 6.0

105

7.0

65750003HM

3 x 50

1960

28.5

65706002HM

2 x 6.0

285

13.0

65750004HM

4 x 50

2510

32.0

www.fscables.com

sales@fscables.com


109

BS 7917 0.6/1kV Shipwiring Power MOG Part No.

65770001HM 65770002HM 65770003HM 65770004HM 65795001HM

Cores x mm²

Weight kg/km

O/D mm

1 x 70 2 x 70 3 x 70 4 x 70 1 x 95

785 2070 2700 3490 1060

16.0 31.0 33.0 36.0 18.0

Part No.

65795003HM 65795004HM 65712001HM 65712003HM 65712004HM

Cores x mm²

Weight kg/km

O/D mm

3 x 95 4 x 95 1 x 120 3 x 120 4 x 120

3680 4780 1300 4490 5830

37.0 42.0 21.0 42.0 46.0

65801512HM

For green/yellow single cores suffix the part code "E" Part No.

Cores x mm²

Tel: 01727 840 841

Fax : 01727 840 842

13.5 14.5 16.5 18.0 23.5 27.5 32.0 14.5 16.0 17.0 20.0 25.0 29.0 34.5 16.5 17.0 19.0 18.0 18.5 20.0 20.0 20.5 23.0 23.0 24.0 26.0 26.0 27.5 30.0 28.0 30.0 33.5 32.5 cables 34.0 38.5 37.0 39.0 43.0 44.0 49.0 48.5 54.0

FS

FS

FS

FS

FS

FS

FS

FS

cables

cables

cables

10.0 10.5 11.5 14.0 18.5 22.0 26.5 11.0 11.5 12.5 15.0 20.0 24.0 29.5 12.0 13.0 14.0 13.0 14.0 15.5 15.0 16.0 18.0 17.5 18.5 20.5 21.0 22.5 25.0 23.5 25.0 28.0 27.0 29.0 32.5 31.0 33.0 37.0 38.0 42.5 41.0 46.0

cables

280 310 390 570 780 1080 1430 320 400 460 650 980 1350 1810 420 505 590 510 595 700 680 780 935 960 1120 1370 1250 1500 1850 1455 1950 2380 2160 2640 3300 2930 3630 4340 4720 5830 5820 7180

BS 7917 658M SW4 Armoured 65801502HM 2 x 1.5 65801503HM 3 x 1.5 65801504HM 4 x 1.5 65801507HM 7 x 1.5 65801512HM 12 x 1.5 65801519HM 19 x 1.5 65801527HM 27 x 1.5 65802502HM 2 x 2.5 65802503HM 3 x 2.5 65802504HM 4 x 2.5 65802507HM 7 x 2.5 65802512HM 12 x 2.5 65802519HM 19 x 2.5 65802527HM 27 x 2.5 65804002HM 2 x 4.0 65804003HM 3 x 4.0 65804004HM 4 x 4.0 65806002HM 2 x 6.0 65806003HM 3 x 6.0 65806004HM 4 x 6.0 65810002HM 2 x 10 65810003HM 3 x 10 65810004HM 4 x 10 65816002HM 2 x 16 65816003HM 3 x 16 65816004HM 4 x 16 65825002HM 2 x 25 65825003HM 3 x 25 65825004HM 4 x 25 65835002HM 2 x 35 65835003HM 3 x 35 65835004HM 4 x 35 65850002HM 2 x 50 65850003HM 3 x 50 65850004HM 4 x 50 65870002HM 2 x 70 65870003HM 3 x 70 65870004HM 4 x 70 65895003HM 3 x 95 65895004HM 4 x 95 65812003HM 3 x 120 65812004HM 4 x 120

O/D mm

cables

Dia. over Bedding mm

cables

Weight kg/km

cables


110

MOG BS 7917 657M-SW4 Shipwiring Instrumentation

BS 7917 657M-SW4 Fire Resistant Unarmoured Instrumentation N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, FireShipwiring Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Fire resistant instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Mica glass tape fire barriers provide circuit integrity whilst the oil resistant SW4 Low Smoke Halogen Free sheathing compound ensures protection to both people and property during a fire. Construction

Electrical Characteristics

Collectively Screened

Conductor Size:

0.75mm²

1.5mm²

Tinned copper wire conductors to IEC 60228 class 2, mica

Conductor Resistance:

<24.5 Ohms/km

<12.1 Ohms/km

glass tape fire barrier EPR insulation, cores twisted into pairs

Insulation Resistance:

940 MOhm x km 730 MOhm x km

or triples, overall foil screen and drain wire, SW4 oil resistant

Mutual Capacitance @ 800Hz:

LSHF sheath - grey, blue or black.

Collective Screen:

80nF/km

90nF/km

Individual Screen:

90nF/km

110nF/km

Individually Screened Tinned copper wire conductors to IEC 60228 class 2, mica glass

Technical Information

tape fire barrier, EPR insulation, cores twisted into pairs or triples, each pair or triple aluminum foil screened with a drain

Voltage Rating:

150/250V

wire, SW4 oil resistant LSHF sheath – grey, blue or black.

Conductor Stranding:

IEC 60228 Class 2, tinned copper

Temperature Rating:

-30°C to +85°C

Bending Radius Static:

8 x overall diameter

Class 5 conductors to IEC 60228 can be supplied on request.

Oxygen Index of Sheath: >31%

Core Identification Pairs - Black & white Triples - Black, white & red

Fire Resistant:

IEC 60331-21

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-22 Cat A

Each pair is identified by a numbered tape or printed numbers

Smoke Emission:

IEC 61034-1 & 2, BS 7622

on the cores.

Halogen Emission:

IEC 60754-1 & 2, BS 6425-1

Oil Resistant:

BS 7655 SW4 section 2.6

Manufactured To:

BS 7917/UKOOA

Part No.

Pairs Collectively Screened 657C0702PHMxx 657C0703PHMxx 657C0707PHMxx 657C0712PHMxx 657C0719PHMxx 657C0720PHMxx 657C0727PHMxx cables

FS

FS cables

657C1502PHMxx 657C1503PHMxx 657C1507PHMxx 657C1512PHMxx 657C1520PHMxx 657C1527PHMxx cables

FS

FS cables

No. of Pairs

mm²

Weight kg/km

O/D mm

2 3 7 12 19 20 27

0.75 0.75 0.75 0.75 0.75 0.75 0.75

180 230 410 620 900 990 1290

12.5 14.0 19.0 24.5 28.5 30.0 33.0

2 3 7 12 20 27

1.5 1.5 1.5 1.5 1.5 1.5

271 410 680 1050 1480 1860

14.0 16.5 21.0 27.5 31.5 33.0

www.fscables.com

sales@fscables.com


BS 7917 657M-SW4 Shipwiring Instrumentation MOG Part No.

No. of Pairs

Pairs Individually Screened 657I0701PHMxx 657I0702PHMxx 657I0703PHMxx 657I0707PHMxx 657I0712PHMxx 657I0720PHMxx 657I0727PHMxx 658I1501PHMxx 658I1502PHMxx 657I1503PHMxx 657I1507PHMxx 657I1512PHMxx 657I1520PHMxx

Part No.

mm²

Weight kg/km

O/D mm

1 2 3 7 12 20 27

0.75 0.75 0.75 0.75 0.75 0.75 0.75

120 165 280 510 850 1300 1710

9.5 12.0 14.0 19.5 23.5 29.0 33.0

1 2 3 7 12 20

1.5 1.5 1.5 1.5 1.5 1.5

145 254 350 760 1210 1990

17.5 14.3 16.5 23.0 29.0 35.5

mm²

Weight kg/km

O/D mm

0.75 0.75 0.75

280 530 820

16.0 22.0 26.5

1.5 1.5 1.5

375 815 1300

16.5 24.8 30.0

0.75 0.75 0.75 0.75

135 325 595 990

10.0 16.5 21.0 26.0

1.5 1.5 1.5 1.5

187 450 960 1610

11.0 18.5 26.0 30.5

No. of Triples

Triples Collectively Screened 657C0703THMxx 3 657C0707THMxx 7 657C0712THMxx 12 657C1503THMxx 657C1507THMxx 657C1512THMxx

3 7 12

Triples Individually Screened 657I0701THMxx 1 657I0703THMxx 3 657I0707THMxx 7 657I0712THMxx 12

To show the colour required please replace xx in the part number with: 05

Grey

01

Blue

00

Black

FS

FS

FS

cables

FS

FS

FS

FS

FS

cables

1 3 7 12

657C0707PHM00

cables

657I1501THMxx 657I1503THMxx 657I1507THMxx 657I1512THMxx

111

cables

Other pair and triple configurations available on request

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables


112

MOG BS 7917 658M-SW4 Shipwiring Instrumentation

BS 7917 658M-SW4 Fire Resistant Armoured Shipwiring Instrumentation N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Manufactured with a galvanised steel wire braid for mechanical protection these fire resistant cables are available in both pairs and triples to provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility and circuit integrity their use has spread from ships to rigs and many onshore/offshore applications. The oil resistant SW4 Low Smoke Halogen Free sheathing compounds ensure that in the event of a fire the cables offer excellent protection to both people and property by not emitting toxic or corrosive gases whilst keeping emergency circuits operating. Construction

Electrical Characteristics

Collectively Screened

Conductor Size:

Tinned copper wire conductors to IEC 60228 class 2, mica glass

Conductor Resistance: <24.5 Ohms/km

<12.1 Ohms/km

tape fire barrier, EPR insulation, cores twisted into pairs or triples,

Insulation Resistance:

730 MOhm x km

overall foil screen and drain wire, LSHF bedding, galvanised steel

Mutual Capacitance @ 800Hz:

wire braid armour, SW4 oil resistant LSHF sheath - grey, blue or

Collective Screen:

80nF/km

90nF/km

black.

Individual Screen:

90nF/km

110nF/km

Individually Screened

0.75mm² 940 MOhm x km

1.5mm²

Technical Information

Tinned copper wire conductors to IEC 60228 class 2, mica glass tape fire barrier, EPR insulation, cores twisted into pairs or

Voltage Rating:

150/250V

triples, each pair aluminum foil screened with a drain wire,

Conductor Stranding:

IEC 60228 Class 2, tinned copper

LSHF bedding, galvanised steel wire braid armour, SW4 oil

Temperature Rating:

-30°C to +85°C

resistant LSHF sheath – grey, blue or black.

Bending Radius Static:

8 x overall diameter

Oxygen Index of Sheath: >31% Class 5 conductors to IEC 60228 can be supplied on request.

Fire Resistant:

IEC 60331-21

Flame Retardant:

IEC 60332-1-2,

Core Identification

IEC 60332-3-22 Cat A

Pairs - Black & white

Smoke Emission:

IEC 61034-1 & 2, BS 7622

Triples - Black, white & red

Halogen Emission:

IEC 60754-1 & 2, BS 6425-1

Oil Resistant:

BS 7655 SW4 section 2.6

Manufactured To:

BS 7917/BS 6883

Each pair is identified by a numbered tape or printed numbers on the cores.

cables

FS

Part No.

No. of Pairs

Pairs Collectively Screened 658C0702PHMxx 2 658C0703PHMxx 3 658C0707PHMxx 7 658C0712PHMxx 12 658C0719PHMxx 19 658C0720PHMxx 20 cables 658C0727PHMxx 27

FS

658C1502PHMxx 658C1503PHMxx 658C1507PHMxx 658C1512PHMxx 658C1520PHMxx 658C1527PHMxx cables

FS

FS cables

2 3 7 12 20 27

mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

0.75 0.75 0.75 0.75 0.75 0.75 0.75

379 460 741 1120 1600 1720 2190

13.5 13.0 17.5 22.5 26.0 27.0 31.0

15.5 17.5 21.5 27.5 32.0 33.0 37.5

1.5 1.5 1.5 1.5 1.5 1.5

477 570 920 1560 2260 2820

13.5 14.5 19.5 26.0 31.0 35.5

17.5 19.0 24.0 31.5 37.5 42.0

www.fscables.com

sales@fscables.com


BS 7917 658M-SW4 Shipwiring Instrumentation MOG Part No.

No. of Pairs

mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

113

Pairs Individually Screened 658I0701PHMxx

1

0.75

260

8.0

12.0

658I0702PHMxx

2

0.75

420

11.0

17.0

658I0703PHMxx

3

0.75

480

13.5

17.5

658I0707PHMxx

7

0.75

795

20.0

22.0

658I0712PHMxx

12

0.75

1225

24.0

28.5

658I0720PHMxx

20

0.75

2050

30.0

36.5

658I0727PHMxx

27

0.75

2410

35.0

41.0

658I1501PHMxx

1

1.5

300

9.5

13.0

658I1502PHMxx

2

1.5

511

13.0

18.0

658I1503PHMxx

3

1.5

650

15.0

21.0

658I1507PHMxx

7

1.5

1030

20.5

25.0

658I1512PHMxx

12

1.5

1650

27.5

32.0

658I1520PHMxx

20

1.5

2690

34.0

41.0

mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

Part No.

No. of Triples

658C0707PHM05

Triples Collectively Screened 658C0703THMxx

3

0.75

550

15.0

19.0

658C0707THMxx

7

0.75

930

19.5

24.5

658C0712THMxx

12

0.75

1450

26.0

31.5

658C1503THMxx

3

1.5

615

15.5

19.5

658C1507THMxx

7

1.5

1010

22.0

25.0

658C1512THMxx

12

1.5

1560

26.0

29.0

Triples Individually Screened 0.75

280

8.5

12.5

3

0.75

590

14.5

19.0

658I0707THMxx

7

0.75

990

20.0

24.5

658I0712THMxx

12

0.75

1650

26.5

32.5

FS

658I1501THMxx

1

1.5

330

10.0

14.0

658I1503THMxx

3

1.5

850

16.5

19.0

658I1507THMxx

7

1.5

1180

20.0

cables 25.0

658I1512THMxx

12

1.5

1740

32.5

38.0

FS

cables

1

658I0703THMxx

cables

FS

658I0701THMxx

FS cables

To show the colour required please replace xx in the part number with: 05

Grey

01

Blue

00

Black

Fax : 01727 840 842

FS

FS

FS

cables

cables

Tel: 01727 840 841

FS

cables

Other pair and triple configurations available on request

cables


114

MOG BFOU Power to IEC 60092-353

BFOU Power to IEC 60092-353 N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV BFOU is similar to RFOU but has the benefit of mica tape around the conductor to maintain circuit integrity for 3 hours when exposed to fire in accordance with IEC 60331-21. Designed to NEK606 and IEC 60092-353 BFOU meets the most stringent fire resistant, flame retardant and low smoke emission tests making it the ideal choice for low voltage power and control applications on FPSO, ship and platform applications. Construction

Technical Information

Tinned stranded copper conductor, mica glass tape fire

Voltage Rating:

0.6/1kV

barrier, EPR insulation, halogen free thermoplastic

Conductor Stranding:

IEC 60228 Class 2, tinned copper

elastomeric bedding, tinned copper wire braid armour,

Current Rating:

FEA-M clause 1881.5 – 11 or IEE regs. table 4H2A+B depending on application

MUD resistant LSHF elastomeric outer sheath. The cross sectional area (mm2) of the screen is shown after the conductor size in the table below.

Black

2 Cores

Light grey, black

3 Cores

Light grey, black, red

4 Cores

Light grey, black, red, blue

-40°C to +85°C

Bending Radius Static:

6 x overall diameter

Oxygen Index of Sheath: >31%

Core Construction 1 Core

Temperature Rating:

5 Cores and above number coded

Fire Resistant:

IEC 60331-21

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission:

IEC 61034-1 & 2

Halogen Emission:

IEC 60754-1 & 2

MUD Resistant:

NEK 606 P5/P12

Manufactured To:

IEC 60092-353, NEK 606

3rd Party Approval:

DNV, approvals may vary between manufacture brands.

Cores x mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

2 x 1.5/4 3 x 1.5/4 4 x 1.5/4 7 x 1.5/6

280 310 390 570

10.0 10.5 11.5 14.0

13.5 14.5 16.5 18.0

cables

BFO01512 BFO01519 BFO01527

12 x 1.5/10 19 x 1.5/10 27 x 1.5/10

780 1080 1430

18.5 22.0 26.5

23.5 27.5 32.0

FS

BFO02502 BFO02503 BFO02504 BFO02507 BFO02512 BFO02519 BFO02527

2 x 2.5/4 3 x 2.5/6 4 x 2.5/6 7 x 2.5/6 12 x 2.5/10 19 x 2.5/10 27 x 2.5/16

320 400 460 650 980 1350 1810

11.0 11.5 12.5 15.0 20.0 24.0 29.5

14.5 16.0 17.0 20.0 25.0 29.0 34.5

FS

BFO04002 BFO04003 BFO04004 BFO06002 BFO06003 BFO06004

2 x 4/6 3 x 4/6 4 x 4/6 2 x 6/6 3 x 6/6 4 x 6/6

420 505 590 510 595 700

12.0 13.0 14.0 13.0 14.0 15.5

16.5 17.0 19.0 18.0 18.5 20.0

BFO06004

Part No.

BFOU Power BFO01502 BFO01503 BFO01504 BFO01507

FS

cables

cables

FS cables

www.fscables.com

sales@fscables.com


115

BFOU Power to IEC 60092-353 MOG Part No.

Cores x mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

BFO10002

2 x 10/10

680

15.0

20.0

BFO10003

3 x 10/10

780

16.0

20.5

BFO10004

4 x 10/10

935

18.0

23.0

BFO16002

2 x 16/16

960

17.5

23.0

BFO16003

3 x 16/16

1120

18.5

24.0

BFO16004

4 x 16/16

1370

20.5

26.0

BFO25001

1 x 25/4

480

11.5

15.5

BFO25002

2 x 25/16

1250

21.0

26.0

BFO25003

3 x 25/16

1500

22.5

27.5

BFO25004

4 x 25/16

1850

25.0

30.0

BFO35001

1 x 35/6

640

13.5

17.0

BFO35002

2 x 35/16

1455

23.5

28.0

BFO35003

3 x 35/16

1950

25.0

30.0

BFO35004

4 x 35/16

2380

28.0

33.5

BFO50001

1 x 50/6

820

15.0

19.5

BFO50002

2 x 50/25

2160

27.0

32.5

BFO50003

3 x 50/25

2640

29.0

34.0

BFO50004

4 x 50/25

3300

32.5

38.5

1 x 70/6

1080

16.5

21.0

2 x 70/35

2930

31.0

37.0

BFO70003

3 x 70/35

3630

33.0

39.0

BFO70004

4 x 70/35

4340

37.0

43.0

BFO95001

1 x 95/10

1380

18.5

BFO95003

3 x 95/50

4720

38.0

BFO95004

4 x 95/50

5830

42.5

cables

FS

23.0 44.0 49.0

FS

1 x 120/10

1710

20.5

3 x 120/60

5820

41.0

BFO12004

4 x 120/60

7180

46.0

BFO15001

1 x 150/10

2030

23.0

28.0

BFO18501

1 x 185/10

2510

25.0

30.0

BFO24001

1 x 240/16

3130

28.0

BFO30001

1 x 300/16

3820

31.0

FS

cables

Fax : 01727 840 842

cables

25.5 48.5 54.0

34.0

FS cables

FS

cables

BFO12001 BFO12003

Tel: 01727 840 841

FS

cables

BFO70001 BFO70002

37.0

FS

cables

FS cables


116

MOG BFOU Instrumentation to IEC 60092-376

BFOU Instrumentation to IEC 60092-376 N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV BFOU instrumentation cables are designed to meet the needs of circuit integrity installations within the offshore industry. They are available as collectively or individually screened options for optimum EMI screening. Fire barrier tapes are combined with a Low Smoke Halogen Free sheath to provide uninterrupted signals during a fire situation. BFOU cables are also resistant to MUD and drilling oils and meet the flame retardance requirements of IEC 60332-3-22 Cat A. Construction

Technical Information

Tinned stranded copper conductor, mica tape, EPR insulation,

Voltage Rating:

250V

overall screen of copper backed polyester tape with a stranded

Conductor Stranding:

IEC 60228 Class 2, tinned copper

copper drain wire, inner sheath of halogen free elastomeric,

Temperature Rating:

-40°C to +85°C

tinned copper wire braid armour, MUD resistant - LSHF

Bending Radius Static:

6 x overall diameter

elastomeric sheath. The individually screened version has a

Oxygen Index Of Sheath: >31%

copper backed polyester tape with a stranded copper drain wire

Fire Resistant:

IEC 60331-21

around each pair or triple.

Flame Retardant:

IEC 60332-1-2, IEC 60332-3-22 Cat A

Smoke Emission:

IEC 61034-1 & 2

Halogen Emission:

IEC 60754-1 & 2

MUD Resistant:

NEK606 Collective Screen S4/S8,

Core Identification Pairs - Light blue, black and numbered Triples – Light blue, black, brown and numbered

Individual Screen S3/S7

Electrical Characteristics Conductor Size:

0.75mm²

IEC 60092-376, NEK606

3rd Party Approval:

DNV, approvals may vary between

1.5mm²

manufacture brands.

Conductor Resistance: <26.7 Ohms/km

<13.7 Ohms/km

L/R Ratio:

26.6mH/Ohm

12.7mH/Ohm

Manufactured To:

Mutual Capacitance @ 800Hz: Collective Screen:

100nF/km

110nF/km

Individual Screen:

110nF/km

125nF/km

Part No.

No. of Pairs

mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

0.75 0.75 0.75 0.75 0.75 0.75 0.75

340 421 450 700 915 1100 1600

10.5 12.0 12.5 16.5 19.5 21.0 26.5

14.5 15.5 16.0 21.0 23.5 25.5 31.5

1.5 1.5 1.5 1.5 1.5 1.5 1.5

450 521 600 1020 1330 1620 2450

13.0 14.0 15.0 20.0 23.5 26.0 32.0

16.5 18.4 19.0 25.0 28.5 30.5 38.5

Pairs Collectively Screened BFC00702xx 2 BFC00703xx 3 BFC00704xx 4 BFC00708xx 8 BFC00712xx 12 BFC00716xx 16 BFC00724xx 24 cables

FS

FS

BFC01502xx BFC01503xx cables BFC01504xx BFC01508xx BFC01512xx BFC01516xx BFC01524xx cables

FS

2 3 4 8 12 16 24

FS cables

www.fscables.com

sales@fscables.com


117

BFOU Instrumentation to IEC 60092-376 MOG Part No.

No. of Pairs

Pairs Individually Screened BFI00701xx 1 BFI00702xx 2 BFI00703xx 3 BFI00704xx 4 BFI00708xx 8 BFI00712xx 12 BFI00716xx 16 BFI00724xx 24 BFI01501xx BFI01502xx BFI01503xx BFI01504xx BFI01508xx BFI01512xx BFI01516xx BFI01524xx Part No.

1 2 3 4 8 12 16 24 No. of Triples

Triples Collectively Screened BFC00702Txx 2 BFC00704Txx 4 BFC00708Txx 8 BFC00712Txx 12 BFC00716Txx 16 BFC00724Txx 24 BFC01502Txx BFC01504Txx BFC01508Txx BFC01512Txx BFC01516Txx BFC01524Txx

2 4 8 12 16 24

O/D mm

0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75

200 370 500 519 820 1075 1320 2050

7.5 11.0 12.5 15.0 17.0 20.5 23.0 29.0

11.0 14.5 16.5 18.5 21.5 25.0 27.5 34.5

1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

260 490 601 650 1140 1520 1950 2900

9.0 13.0 15.5 15.5 21.0 25.0 29.0 35.5

12.0 17.0 19.5 19.5 25.0 30.0 34.0 42.0

mm²

Weight kg/km

Dia. over Bedding mm

O/D mm

0.75 0.75 0.75 0.75 0.75 0.75

415 550 880 1180 1400 2150

12.0 14.0 18.5 22.0 24.0 30.0

15.5 18.0 23.0 26.5 29.0 35.0

1.5 1.5 1.5 1.5 1.5 1.5

550 770 1270 1720 2330 3350

14.5 17.0 22.5 27.0 30.0 37.0

18.0 21.0 27.0 32.0 35.0 43.5

0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75

220 420 580 591 980 1320 1650 2520

8.0 12.0 14.0 14.5 18.5 22.5 25.5 31.5

11.0 15.0 17.0 20.0 23.0 27.0 30.0 37.5

1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

290 570 730 825 1410 1980 2620 3790

9.5 14.5 17.5 17.0 22.5 28.5 31.5 39.5

12.5 18.5 cables 20.5 21.0 27.0 33.0 37.5 46.5

05

Grey

01

Blue

00

Black

Other pair and triple configurations available on request. 2.5mm2 conductor sizes are available in some sizes, please contact us for more information.

Tel: 01727 840 841

Fax : 01727 840 842

FS

FS

FS

FS

FS

FS

FS

FS

cables

cables

cables

To show the colour required please replace xx in the part number with:

BFC0070805

cables

1 2 3 4 8 12 16 24

Dia. over Bedding mm

cables

BFI01501Txx BFI01502Txx BFI01503Txx BFI01504Txx BFI01508Txx BFI01512Txx BFI01516Txx BFI01524Txx

Weight kg/km

cables

Triples Individually Screened BFI00701Txx 1 BFI00702Txx 2 BFI00703Txx 3 BFI00704Txx 4 BFI00708Txx 8 BFI00712Txx 12 BFI00716Txx 16 BFI00724Txx 24

mm²

cables


118

RUBBER & CRANE H05RR-F

H05RR-F Multicores XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV Used extensively for trailing and flexible supply leads, these rubber cables remain flexible even at sub-zero temperatures. H05RR-F uses a standard grade rubber compound for the outer sheath and is suitable for light duty applications. Application

Technical Information

Light portable tools, temporary or portable lighting,

Voltage Rating:

Working 300/500V

extension leads for indoor or outdoor use where there

Temperature Rating:

-25°C to +60°C

is minimal physical damage expected.

Bending Radius:

Flexing 15 x cable diameter

Test 2000V

Static 6 x cable diameter Construction

Current Rating:

H05RR-F Refer to IEE Regs Table 4HF3A&B

Conductor Stranding: To IEC 60228 Class 5 &

Fine copper wire strands to IEC 60228 class 5.

VDE 0295 Class 5.

Rubber insulation colour coded to BS 7671/HD 308 S2. Cores twisted together. Black rubber outer sheath to BS 6500:2000 table 12 and BS 7919:2001 table 10.

Part No.

55101503

cables

FS

FS cables

Cores x mm²

O/D mm

55100702

2 x 0.75

6.6

55100703

3 G 0.75

7.1

55101002

2 x 1.0

7.1

55101003

3 G 1.0

7.6

55101004

4 G 1.0

8.1

55101502

2 x 1.5

8.8

55101503

3 G 1.5

9.4

55101504

4 G 1.5

10.3

55101505

5 G 1.5

10.6

55102502

2 x 2.5

10.2

55102503

3 G 2.5

10.8

55102504

4 G 2.5

12.1

55102505

5 G 2.5

11.8

G = With

Green/Yellow

X = Without

Green/Yellow

The overall diameter given has been taken from measuring actual cables, however rubber cables vary considerably in diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the stock you will be sent. Also available in a special blue sheathed version suitable for use in drinking water.

cables

FS

FS cables

www.fscables.com

sales@fscables.com


119

H07RN-F RUBBER & CRANE H07RN-F Single & Multicores

Used extensively for trailing and flexible supply leads in either single or multicore versions, these rubber cables remain flexible even at sub-zero temperatures. H07RN-F uses neoprene (PCP) for its sheath. The improved abrasion resistance and the ability to withstand many oils and chemicals make the neoprene sheathed cables suitable for the most arduous conditions. Application

Technical Information

Portable saws, grinders, welders, pumps, transformers, as temporary lighting cable and feed cable to heavy mobile equipment. Single cores and large multicores are often used as distribution cables from mobile generators.

Voltage Rating:

Working 450/750V

Temperature Rating:

-20°C to +60°C. + 85°C for static applications

Bending Radius:

Flexing 15 x cable diameter

Construction

Current Rating:

Fine copper wire strands to IEC 60228 class 5. Rubber insulation colour coded to BS 7671/HD 308 S2 (cables with over 5 cores, A07RN-F, are number coded). Cores twisted together. Black neoprene (PCP) outer sheath to BS 7919:2001 table 14.

Conductor Stranding: To IEC 60228 Class 5 & VDE 0295 Class 5.

Test 3000V

Static 6 x cable diameter

Part No.

92 111 134 48 109 137 169 206 371 546 777 1090 1300 62 162 198 244 299 461 758 1100 1590 88 220 276 343 431 116 295 370 474 585 182 522

8.3 8.9 9.7 5.9 8.7 9.7 10.7 11.6 16.0 20.0 23.5 27.5 31.0 6.5 10.6 11.4 12.6 14.0 18.2 24 24.5 32.1 7.5 12.0 13.1 14.4 16.3 8.3 13.7 14.8 16.7 18.4 10.1 18.1

Green/Yellow

X = Without

57110003 57110004 57110005 57116001 57116002 57116003 57116004 57116005 57125001 57125003 57125004 57125005 57135001 57135003 57135004 57135005 57150001 57150003 57150004 57150005 57170001 57170003 57170004 57170005 57195001 57195003 57195004 57112001 57112003 57112004 57115001 57115004 57118501 57118504 57124001 57130001

3 G 10 4 G 10 5 G 10 1 x 16 2 x 16 3 G 16 4 G 16 5 G 16 1 x 25 3 G 25 4 G 25 5 G 25 1 x 35 3 G 35 4 G 35 5 G 35 1 x 50 3 G 50 4 G 50 5 G 50 1 x 70 3 G 70 4 G 70 5 G 70 1 x 95 3 G 95 4 G 95 1 x 120 3 G 120 4 G 120 1 x 150 4 G 150 1 x 185 4 G 185 1 x 240 1 x 300

Green/Yellow

668 20.1 822 21.6 1010 24.2 250 11.4 738 21.6 906 22.6 1120 24.6 1380 27.1 361 13.4 1360 27.4 1730 30.7 2110 33.6 469 14.7 1700 29.7 2180 33.2 2680 41.3 671 17.5 2410 35.4 3060 39.2 4383 47.3 892 19.6 3180 39.6 4040 43.3 5398 56.2 1140 22.0 4070 45.2 5300 50.5 1420 24.2 4936 cables 53.7 6499 59.5 1760 26.6 8101 65.5 2090 28.8 10029 76.5 2710 32.2 3310 34.9

FS

FS

FS

FS

FS

FS

The overall diameter given has been taken from measuring actual cables, however rubber cables vary considerably in diameter from one manufacturer to another. If the diameter is critical, please ask at time of order and we will check the stock you will be sent. Also available in a special blue sheathed version suitable for use in drinking water.

Tel: 01727 840 841

Fax : 01727 840 842

57101503

FS

cables

cables

cables

2 x 1.0 3 G 1.0 4 G 1.0 1 x 1.5 2 x 1.5 3 G 1.5 4 G 1.5 5 G 1.5 7 G 1.5 12 G 1.5 19 G 1.5 27 G 1.5 37 G 1.5 1 x 2.5 2 x 2.5 3 G 2.5 4 G 2.5 5 G 2.5 7 G 2.5 12 G 2.5 19 G 2.5 27 G 2.5 1 x 4.0 2 x 4.0 3 G 4.0 4 G 4.0 5 G 4.0 1 x 6.0 2 x 6.0 3 G 6.0 4 G 6.0 5 G 6.0 1 x 10 2 x 10

O/D mm

cables

O/D mm

Weight kg/km

cables

G = With

Weight kg/km

Cores x mm²

cables

57101002 57101003 57101004 57101501 57101502 57101503 57101504 57101505 57101507 57101512 57101519 57101527 57101537 57102501 57102502 57102503 57102504 57102505 57102507 57102512 57102519 57102527 57104001 57104002 57104003 57104004 57104005 57106001 57106002 57106003 57106004 57106005 57110001 57110002

Cores x mm²

Part No.

H07RN-F Refer to IEE Regs Table 4F1A&B

FS cables


120

RUBBER & CRANE NSHTöu

NSHTöu Drum Reeling N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV NSHTöu is designed specifically for drum reeling applications. On anything from dockside cranes to automated conveyor systems, NSHTöu copes with incredible workloads. Good UV and weather resistance makes the cable suitable for exposed outdoor installation. A special low temperature type is available to work down to -40°C. Other sizes and high tensile versions using Kevlar strain relief elements are also available. Medium and high voltage variants are available usually with red PCP outer sheaths.

Construction

Technical Information

Fine copper wire strands to IEC 60228. Rubber

Voltage Rating:

Working 0.6/1kV

insulation, 4 & 5 core colour coded, six core and above,

Temperature Rating:

Flexing -25°C to +60°C

black with white numbers. Green/yellow earth core in all

Bending Radius:

Up to 20mm diameter: 10 x cable diameter

cables. Cores twisted together with short lay length. Black neoprene (PCP) dual layer outer sheath with

Flexing above 20mm diameter:

integral textile braid.

12.5 x cable diameter Part No.

51106004

cables

FS

FS cables

Cores x mm²

Weight kg/km

O/D mm

51101504

4 x 1.5

301

15

51104005

5x4

636

21

51101505

5 x 1.5

342

16

51104008

8x4

1015

27

51101507

7 x 1.5

419

20

51106004

4x6

688

21

51101512

12 x 1.5

620

22

51106005

5x6

855

23

51101518

18 x 1.5

875

27

51110004

4 x 10

1047

26

51101524

24 x 1.5

1020

29

51110005

5 x 10

1190

28

51101530

30 x 1.5

1362

31

51116004

4 x 16

1280

29

51101542

42 x 1.5

1724

35

51116005

5 x 16

1803

32

51102504

4 x 2.5

374

17

51102505

5 x 2.5

486

19

51125004

4 x 25

2102

35

51102507

7 x 2.5

506

22

51135004

4 x 35

2751

39

51102508

8 x 2.5

704

24

51150004

4 x 50

3695

45

51102512

12 x 2.5

891

26

51170004

4 x 70

5401

49

51195004

4 x 95

6985

57

4 x 120

8294

60

4 x 150

51102516

16 x 2.5

1103

28

Part No.

51102518

18 x 2.5

1208

30

51112004

51102519

19 x 2.5

1282

31

51115004

Cores x mm²

Weight kg/km

FS cables

O/D mm

8989

65

2142

40

51102524

24 x 2.5

1562

35

51301525* 25x1.5+5x1.5(C)

51102530

30 x 2.5

1819

36

51302519* 19x2.5+5x1.5(C)

1757

34

51102536

36 x 2.5

2327

40

51302525* 25x2.5+5x1.5(C)

2010

37

51102542

42 x 2.5

2860

45

51501506

3 x (2 x 1.5)(C)

608

23

51104004

4x4

526

19

51501512

6 x (2 x 1.5)(C)

984

31

* The 5 x 1.5mm2 signal cores are individually screened.

cables

FS

Test 2500V

www.fscables.com

sales@fscables.com


121

Reelflex PUR-H RUBBER & CRANE Reelflex PUR-H Drum Reeling

Reelflex PUR-H is part of the latest generation of drum reeling cables. When compared to the standard rubber NSHTöu, Reelflex PUR-H is significantly smaller in overall diameter and lighter in weight. This allows the use of lighter winding/reeling equipment offering considerable cost savings. Ideal for use inside or in the open air, these cables emit very little smoke and are halogen free, making them suitable for sensitive applications in the event of fire. Construction

Technical Information

Fine copper strands to IEC 60228 insulated with

Voltage Rating:

Working 0.6/1kV

halogen free polyester, cores laid around a central

Temperature Rating:

Fixed Installation -50°C to +80°C

Test 2500V

Flexing -40°C to +80°C

textile suspension unit using a short length of twist. Anti-torsion braid embedded between the inner and

Bending Radius:

Flexing 6 x cable diameter

outer halogen free black polyurethane sheath. Some large sizes may have a split earth construction. Please check at time of order if this is critical.

51101504P 51101505P 51101507P 51101512P 51101518P 51101524P 51101530P 51101542P 51301525 51102504P 51102505P 51102507P 51102512P 51102518P 51102524P 51102530P 51302519 51104004P 51104005P 51106004P 51106005P 51110004P 51110005P 51116004P 51116005P 51125004P 51135004P 51150004P 51170004P 51195004P 51112004P 51115004P

4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 24 x 1.5 30 x 1.5 42 x 1.5 25 x 1.5 + 5 x 1.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5 24 x 2.5 30 x 2.5 19 x 2.5 + 5 x 1.5 4x4 5x4 4x6 5x6 4 x 10 5 x 10 4 x 16 5 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 4 x 120 4 x 150

1200 1500 2000 2500 2500 2500 2500 2500 2500 1500 1800 2500 2500 2500 2500 2500 2500 1800 2000 2000 2500 2000 2500 2500 2500 2500 2500 3000 4200 5700 7200 9000

155 178 231 359 474 590 710 980 730 208 241 308 480 679 820 970 820 281 318 372 426 611 704 924 1067 1270 1720 2630 3326 4695 5565 6933

Tel: 01727 840 841

Fax : 01727 840 842

O/D mm

10.5 11.2 12.6 16.1 17.0 21.1 23.1 27.3 23.4 11.5 12.2 13.2 19.5 19.8 24.1 27.3 24.3 12.7 13.7 14.1 15.1 17.9 19.5 22.3 cables 24.2 25.5 28.3 34.2 39.8 47.1 52.1 56.5

51102518P

FS

FS

FS

FS

FS

FS

FS

FS

cables

cables

cables

Weight kg/km

cables

Tensile Stength Newtons

cables

Cores x mm²

cables

Part No.

cables


122

RUBBER & CRANE Flat PVC Cables

Flat PVC Cables PVC Flat cables offer good low temperature durability, flexing to -15ºC. Their relatively light weight increases the options available to designers as does the tight bending radius of 10 x the thickness of the cable. Used mainly within buildings on a wide variety of applications. These cables are not suitable for use in elevators.

Construction

Technical Information

Fine copper wire strands to IEC 60228 class 5. PVC

Voltage Rating:

insulation, colour coded for cables with 2-5 cores,

0.75 & 1mm2

300/500V

1.5 - 50mm2

450/750V

six cores and above black PVC insulation with white

Temperature Rating:

Flexing -15°C to +70°C

numbers. A green/yellow earth conductor is

Bending Radius:

Flexing 10 x cable thickness

included. Cores laid parallel. Black cold resistant PVC

Current Rating:

Refer to IEE Regs Table 4F3A&B

outer sheath.

Conductor Stranding:

To IEC 60228 Class 5

58101512

cables

FS

FS cables

cables

FS

Part No.

Cores x mm²

Weight kg/km

O/D mm

58100712 58100718 58100724 58101005 58101008 58101012 58101016 58101018 58101024 58101504 58101505 58101507 58101508 58101510 58101512 58101518 58101524 58102504 58102505 58102507 58102508 58102510 58102512 58102524 58104004 58104005 58104007 58106004 58110004 58116004 58125004 58135004 58150004

12 x 0.75 18 x 0.75 24 x 0.75 5 x 1.0 8 x 1.0 12 x 1.0* 16 x 1.0* 18 x 1.0 24 x 1.0 4 x 1.5 5 x 1.5 7 x 1.5 8 x 1.5 10 x 1.5 12 x 1.5 18 x 1.5 24 x 1.5 4 x 2.5 5 x 2.5 7 x 2.5 8 x 2.5 10 x 2.5 12 x 2.5 24 x 2.5 4 x 4.0 5 x 4.0 7 x 4.0 4 x 6.0 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50

260 380 490 120 205 335 465 450 590 170 190 220 270 320 390 670 790 200 260 350 390 490 580 1200 320 400 540 432 680 970 1490 1980 2800

4.2 x 33.8 4.2 x 50.2 4.2 x 65.6 4.4 x 15.5 4.4 x 24.8 9.5 x 22.5 9.5 x 28.7 4.4 x 53.8 4.4 x 70.4 4.5 x 13.6 4.5 x 18.2 4.5 x 23.9 4.9 x 27.2 4.9 x 34.0 4.9 x 39.8 4.9 x 61.6 4.9 x 82.0 5.6 x 16.8 5.6 x 22.0 5.6 x 29.2 5.6 x 32.8 6.0 x 41.4 6.0 x 48.6 6.0 x 104 7.0 x 21.2 7.0 x 27.4 7.0 x 36.6 8.2 x 24.8 10.0 x 29.6 11.2 x 34.4 13.7 x 42.6 15.4 x 47.6 18.2 x 57.5

* Cores laid in Quad Format Low Smoke Halogen Free versions, other core combinations and individually screened cores are available on request. Please call us with your requirements.

FS cables

www.fscables.com

sales@fscables.com


123

Photovoltaic Cables RUBBER & CRANE Photovoltaic Cables With the growth in renewable energy sources the demand for specialist cables to meet specific needs has also increased. While the cables used to link solar panels to each other or to a regulator are relatively simple, the environments they operate in can be very hostile. Ultraviolet (UV) can be extremely damaging to conventional cable, breaking down standard insulation within a matter of months in some cases. Heat and weather can also be very destructive.

PV0400100

The FSC range of solar panel or PV cables are designed to work in extreme conditions with a temperature range up to 120ºC and excellent UV stability.

Construction

Technical Information

Tinned copper class 5 conductors, cross

Voltage Rating:

linked polyolefin insulation, cross linked Temperature Rating:

polyolefin sheath.

Minimum Bending Radius: Part No.

Size mm²

Stranding & mm

Electrical Resistance Ohm/km

Working

0.6/1kV

Test

3000V AC

Static

-40ºC to + 120ºC

Flexing

-40ºC to + 90ºC

4 x cable diameter Weight kg/km

O/D mm

PV02501xx

2.5

50 x 0.26

7.98

47

5.5

PV04001xx

4

56 x 0.31

4.95

76

6.1

PV06001xx

6

84 x 0.31

3.30

105

7.5

PV10001xx

10

80 x 0.41

1.91

151

8.9

PV16001xx

16

128 x 0.41

1.21

232

10.0

PV25001xx

25

200 x 0.41

0.780

342

11.4

PV35001xx

35

280 x 0.41

0.554

473

12.9

PV50001xx

50

400 x 0.41

0.386

648

15.3

PV70001xx

70

356 x 0.51

0.272

861

17.5

PV95001xx

95

485 x 0.51

0.206

1126

20.1

FS

cables

FS

Black

03

Red

FS

FS

cables

cables

00

cables

To show the colour required please replace xx in the part number with:

cables

FS

cables

FS

Cables with different insulation materials and jacket materials may be offered. If you require the cable to have specific approvals please state at time of enquiry.

Tel: 01727 840 841

Fax : 01727 840 842

FS

cables

FS cables


124

ROBOTICS Hi-Flex HF-100 & HF-100-C PUR Hi-Flex HF-100 & HF-100-C PUR Abrasion on cables that are constantly flexing is becoming a much more widespread problem. To overcome this, FS Cables have introduced the HF-100 range of polyurethane sheathed cables which will outlast conventional PVC sheathing.

22501007

The low friction polyurethane sheath resists wear caused by constant rubbing either in a cable chain or where free movement brings the cable into contact with part of the machine. Suitable for use in cable chains as well as for free movement the HF-100 range will provide a long term solution to many regular flexing applications. Both the screened and unscreened versions use fleece tapes and talcum to enable the core bundle and, where appropriate, the screening braid to move as the cable flexes. This reduces the stress imposed on the conductors and braid. Construction - HF-100

Technical Information

Very fine copper wire strands to IEC 60228 Class 6. Black polyolefin insulation with white numbers. A green/yellow earth core is included in cables with more than 2 cores. Cores twisted in layers & fleece taped. Textured grey polyurethane sheath to RAL 7001.

Voltage Rating:

Construction - HF-100-C Screened Very fine copper wire strands to IEC 60228 Class 6. Black polyolefin insulation with white numbers. A green/yellow earth core is included in cables with more than 2 cores. Cores twisted in layers & textile taped. Grey PVC inner sheath. Fleece tape. Tinned copper wire braid. Fleece wrap. Textured grey polyurethane outer sheath to RAL 7001. Part No.

cables

FS

FS

Cores x mm²

O/D mm

HF-100 20500502 20500503 20500504 20500505 20500507 20500512 20500518 20500519 20500520 20500525 20500527 20500530 20500536

2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 19 x 0.5 20 x 0.5 25 x 0.5 27 x 0.5 30 x 0.5 36 x 0.5

5.5 5.8 6.2 6.7 7.7 9.7 11.2 11.6 12.0 13.9 14.4 15.5 16.2

20500702 20500703 20500704 20500705 20500707 20500712 20500718 20500720 20500725 20500727

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 20 x 0.75 25 x 0.75 27 x 0.75

6.1 6.4 6.8 7.4 8.8 10.8 12.7 13.4 15.1 15.6

cables

cables

FS

FS cables

www.fscables.com

300/500V Working Test 3000V Temperature Rating: Flexing -30°C to+80°C Bending Radius: Flexing 5 x cable diameter Current Rating: Refer to IEE Regs Table 4F3A&B Conductor Stranding: To IEC 60228 Class 6 & VDE 0295 Table 4 Also available in 0.14mm2, 0.25mm2 and 0.34mm2 screened or unscreened with DIN47100 colour codes. Please see page 126-127. Reduced overall diameter versions are now available. Please call for details. Part No.

Cores x mm²

O/D mm

20500730 20500736

30 x 0.75 36 x 0.75

16.2 18.0

20501002 20501003 20501004 20501005 20501007 20501012 20501018 20501020 20501025 20501027 20501030 20501036

2x1 3x1 4x1 5x1 7x1 12 x 1 18 x 1 20 x 1 25 x 1 27 x 1 30 x 1 36 x 1

6.7 7.1 7.5 8.6 0.2 12.8 14.3 14.7 16.9 17.6 18.2 20.3

20501502 20501503 20501504 20501505 20501507 20501512 20501518 20501520

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 20 x 1.5

7.9 8.3 8.9 9.9 11.9 14.9 16.8 17.6

sales@fscables.com


125

Hi-Flex HF-100 & HF-100-C PUR ROBOTICS Part No.

20.8 21.1 21.7 23.5

20502503 20502504 20502505 20502507 20502512 20502518 20502525

3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5 25 x 2.5

9.8 10.7 11.5 13.5 17.3 20.3 25.0

20504004 20504005

4x4 5x4

13.1 14.8

20506004 20506005

4x6 5x6

14.9 16.9

20510004

4 x 10

19.2

20516004

4 x 16

24.0

20525004

4 x 25

26.3

Cores x mm²

O/D mm

22500502 22500503 22500504 22500505 22500507 22500512 22500518 22500520 22500525 22500527 22500530 22500536

2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 20 x 0.5 25 x 0.5 27 x 0.5 30 x 0.5 36 x 0.5

8.2 8.9 9.1 9.6 10.8 13.1 14.8 14.9 17.8 18.0 18.1 18.6

22500702 22500703 22500704 22500705 22500707 22500712 22500718 22500720 22500725

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 20 x 0.75 25 x 0.75

8.5 8.9 9.9 10.5 11.7 13.7 15.5 16.3 18.9

Part No.

Tel: 01727 840 841

O/D mm

22500727 22500730 22500736

27 x 0.75 30 x 0.75 36 x 0.75

19.0 19.0 20.4

22501002 22501003 22501004 22501005 22501007 22501012 22501018 22501020 22501025 22501027 22501030 22501036

2x1 3x1 4x1 5x1 7x1 12 x 1 18 x 1 20 x 1 25 x 1 27 x 1 30 x 1 36 x 1

8.9 9.2 9.7 10.5 12.7 14.9 16.9 16.9 21.0 21.1 21.2 22.5

22501502 22501503 22501504 22501505 22501507 22501512 22501518 22501520 22501525 22501527 22501530 22501536

2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 20 x 1.5 25 x 1.5 27 x 1.5 30 x 1.5 36 x 1.5

10.2 10.9 11.8 12.0 13.9 17.0 20.3 20.9 24.1 24.4 24.8 27.0

22502503 22502504 22502505 22502507 22502512 22502518

3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5

11.7 12.7 13.6 15.9 18.1 20.9

22506004

4x6

FS

FS

Fax : 01727 840 842

FS

cables

FS

FS

FS

FS

FS

cables

20.4

cables

cables

25 x 1.5 27 x 1.5 30 x 1.5 36 x 1.5

Cores x mm²

cables

20501525 20501527 20501530 20501536

Part No.

cables

O/D mm

cables

Cores x mm²

cables


126

ROBOTICS HF-120 Unscreened & HF-120-C Screened HF-120 Unscreened & HF-120-C Screened

20500112

Hi-Flex 120 & 120-C screened data cables are designed to last even in the most hostile chain or free movement applications. The HF-120-C copper braid screened version protects the signal from EMI while the TPE insulation supports the highly flexible conductors. Abrasion is reduced to a minimum by using a polyurethane low friction sheath. For maximum life Hi-Flex Data cables should not be exposed to torsional stresses or twisting. Many sizes now available with UL approval.

Construction - HF-120 & HF-120-C

Technical Information

Very fine copper wire strands. Polyolefin insulation colour coded to DIN 47100. Cores twisted in layers & fleece taped. (Screened versions have a tinned copper wire braid & fleece wrap). Low friction polyurethane outer sheath. Colour chart page 80.

Voltage Rating:

Part No.

22500207

cables

FS

FS cables

cables

FS

FS cables

Cores x mm²

Weight kg/km

O/D mm

HF-120 Unscreened 20500102 2 x 0.14 20500103 3 x 0.14 20500104 4 x0.14 20500105 5 x 0.14 20500107 7 x 0.14 20500110 10 x 0.14 20500112 12 x 0.14 20500114 14 x 0.14 20500118 18 x 0.14 20500125 25 x 0.14

22 27 30 36 48 63 69 73 85 125

4.1 4.4 4.7 5.0 5.8 6.0 6.1 6.7 7.0 8.3

20500202 20500203 20500204 20500205 20500207 20500210 20500212 20500214 20500218 20500225

2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 7 x 0.25 10 x 0.25 12 x 0.25 14 x 0.25 18 x 0.25 25 x 0.25

26 30 39 49 59 83 95 106 129 168

4.3 4.6 5.0 5.2 6.1 7.4 8.2 8.5 9.0 11.1

20500302 20500303 20500304 20500305 20500307 20500310 20500312 20500314 20500318 20500325

2 x 0.34 3 x 0.34 4 x 0.34 5 x 0.34 7 x 0.34 10 x 0.34 12 x 0.34 14 x 0.34 18 x 0.34 25 x 0.34

33 43 55 66 79 107 128 148 180 250

4.8 95.2 5.9 6.4 7.3 8.8 8.9 9.4 10.3 12.4

www.fscables.com

Temperature Rating: Bending Radius:

Part No.

250V Working Test 1500V Flexing -30°C to +80°C Flexing 7.5 x cable diameter

Cores x mm²

Weight kg/km

O/D mm

HF-120-C Unscreened 22500102 2 x 0.14 22500103 3 x 0.14 22500104 4 x 0.14 22500105 5 x 0.14 22500107 7 x 0.14 22500110 10 x 0.14 22500112 12 x 0.14 22500114 14 x 0.14 22500118 18 x 0.14 22500125 25 x 0.14

31 35 40 45 59 79 93 102 113 150

4.6 4.8 5.0 5.2 5.7 6.2 6.7 7.4 7.9 9.6

22500202 22500203 22500204 22500205 22500207 22500210 22500212 22500214 22500218 22500225

2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 7 x 0.25 10 x 0.25 12 x 0.25 14 x 0.25 18 x 0.25 25 x 0.25

36 41 47 63 79 10 119 139 158 196

4.8 5.4 5.7 6.1 6.7 68.3 8.6 8.8 9.5 11.5

22500302 22500303 22500304 22500305 22500307 22500310 22500312 22500314 22500318 22500324 22500325

2 x 0.34 3 x 0.34 4 x 0.34 5 x 0.34 7 x 0.34 10 x 0.34 12 x 0.34 14 x 0.34 18 x 0.34 24 x 0.34 25 x 0.34

44 58 79 86 110 153 164 183 224 319 325

5.6 6.0 6.3 6.6 7.9 9.1 9.6 9.8 10.7 13.1 13.2

sales@fscables.com


127

HF-120-C-TP Paired Screened ROBOTICS HF-120-C-TP Paired Screened The Hi-Flex twisted pair data cable is ideally suited to mechanically challenging data transmission applications. The tough polyurethane jacket is cut and abrasion resistant, while being unaffected by many solvents and oils. The tinned copper braid screen copes well with frequent flexing and at the same time maintains signal integrity by minimising the efforts of electromagnetic interference. Many sizes now available with UL approval.

Construction - HF-120-C Screened

Technical Information

Very fine copper wire strands. Polyolefin insulation colour coded to DIN 47100. Cores twisted in pairs and laid up with fleece wrap, tinned copper wire braid. Fleece wrap. Low friction polyurethane outer sheath.

Voltage Rating:

Part No.

22600201 22600202 22600203 22600204 22600205 22600206 22600208 22600210 22600214

Pairs x mm²

Weight kg/km

O/D mm

1 x 2 x 0.25 2 x 2 x 0.25 3 x 2 x 0.25 4 x 2 x 0.25 5 x 2 x 0.25 6 x 2 x 0.25 8 x 2 x 0.25 10 x 2 x 0.25 14 x 2 x 0.25

38 44 46 59 70 79 117 126 163

4.9 5.9 6.2 6.6 7.7 8.2 9.1 10.3 11.2

51 79 90 118 135 162 240 255 328

5.5 7.0 8.4 9.2 10.2 11.3 12.3 14.7 15.9

Pairs x mm²

Weight kg/km

O/D mm

22600701

1 x 2 x 0.75

108

6.1

22600702

2 x 2 x 0.75

115

8.6

22600703

3 x 2 x 0.75

123

9.6

22600704

4 x 2 x 0.75

148

10.4

22600705

5 x 2 x 0.75

180

11.5

22600706

6 x 2 x 0.75

209

12.7

22600708

8 x 2 x 0.75

305

13.8

22600710

10 x 2 x 0.75

327

16.3

22600714

14 x 2 x 0.75

420

17.8

22601001

1x2x1

108

6.3

22601002

2x2x1

128

9.1

22601003

3x2x1

140

22601004

4x2x1

171

22601005

5x2x1

206

9.9

FS

FS

FS

cables

FS

FS

FS

FS

FS

10.8 11.8

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

1 x 2 x 0.5 2 x 2 x 0.5 3 x 2 x 0.5 4 x 2 x 0.5 5 x 2 x 0.5 6 x 2 x 0.5 8 x 2 x 0.5 10 x 2 x 0.5 14 x 2 x 0.5

Part No.

250V Working Test 1500V Flexing -30°C to +80°C Flexing 10 x cable diameter

cables

22600501 22600502 22600503 22600504 22600505 22600506 22600508 22600510 22600514

Temperature Rating: Bending Radius:

22600504

cables


128

ROBOTICS HF-265 PUR Encoder HF-265 PUR Encoder

26500241

Used for precise data transmission, these cables meet the specific requirements of automation control gear manufacture. Fine copper wire strands with high performance insulation and sheathing materials make them ideal for regular flexing applications including use in cable chains where cut and abrasion resistance is vital. Manufactured to DESINA® with UL and CSA approval these cables also conform to EU low voltage guide lines 73/23/EWG ™,ensuring they are widely accepted around the world. A wide variety of core combinations are manufactured as standard but please call us to discuss your specific needs. We are constantly increasing the standard range and will produce special designs for low minimum order quantities.

Construction - HF-265 PUR Encoder

Technical Information

Very fine copper wire strands to IEC 60228 Class 6. Polyproplene insulation, colour coded. Cores twisted in layers, including screened pairs & fleece taped. Tinned copper wire braid. Fleece wrap. Low friction polyurethane outer sheath. Colour green.Please note individual types may vary in construction from the above.

Voltage Rating:

Part No.

cables

FS

FS cables

265001125 265001145 265001545 26500135 26500131 26500145 26500275 26500241 26500345 26500509 26500132 26500134 26500102 26500104 26500108 26500212 26500224 26500144

Temperature Rating: Bending Radius:

Working 300V Test 2000V Flexing -30°C to +80°C Flexing 10 x cable diameter

Cores x mm²

Weight kg/km

O/D mm

System

10 x 0.14 + 2 x 0.5 10 x 0.14 + 4 x 0.5 15 x 0.14 + 4 x 0.5 3 x (2 x 0.14) + 2 x (0.5) 3 x (2 x 0.14) + 2 x (1.0) 4 x 2 x 0.14 + 4 x 0.5 4 x 2 x 0.25 + 2 x 0.5 4 x 2 x 0.25 + 2 x 1.0 4 x 2 x 0.38 + 4 x 0.5 9 x 0.5 3 x (2 x 0.14)+4 x 0.14 + 2 x 0.5 3x(2x0.14)+4x0.14+4x0.23+2x0.5 2 x 2 x 0.18 4 x 2 x 0.18 8 x 2 x 0.18 12 x (2 x 0.25) 4 x (2 x 0.14) 4 x 2 x 0.14 + 4 x 0.25

70 86 127 101 109 111 123 135 199 126 127 149 45 57 126 208 92 97

8.1 8.5 8.9 8.2 8.5 8.3 8.9 8.9 8.7 8.7 9.1 10.2 5.7 6.6 8.7 12.6 5.9 6.3

Heidenhain Heidenhain Bosch Heidenhain/Sinumerik Heidenhain Heidenhain Indramat Indramat Sinumerik Indramat Sinumerik Sinumerik Sinumerik Sinumerik Sinumerik Sinumerik Heidenhain Heidenhain

cables

FS

FS cables

www.fscables.com

sales@fscables.com


129

HF-275 PUR Servo & Feedback Cables ROBOTICS HF-275 PUR Servo & Feedback Cables Cables combining control, signal and power cores are now commonly used in industrial automation. Fine copper wire strands with high performance insulation and sheathing material make them ideal for regular flexing applications. A wide variety of core combinations are manufactured as standard but please call us to discuss your specific needs. We are constantly increasing the standard range and will produce special designs for low minimum order quantities.

Construction - HF-275 PUR Servo

Technical Information

Power cores: very fine copper wire strands, polyolefin insulation with cores 1-3 black with white numbers, the fourth core is a green/yellow earth. Control cores: very fine copper wire strands, black TPE insulation with white numbers. Aluminium/polyester foil with a tinned copper braid screen, around each pair there is a polyester foil wrap. Power & signal cores are twisted together with very short lay lengths. Synthetic fleece with overall tinned copper wire braid, low friction polyurethane sheath.

Voltage Rating:

Part No.

EC 0.6/1kV Power cores Test V. 4000V UL/CSA 1000V Control cores Test V. 2000V Flexing -30°C to +80°C Flexing 7.5 x cable diameter

These cables have UL and CSA approval as well as meeting the requirements of DESINA®.

Weight kg/km

4G 0.75 + 2 x (2 x 0.34) 4G 1 + 2 x (2 x 0.75) 4G 1.5 + 2 x (2 x 0.5) 4G 1.5 + 2 x (2 x 0.75) 4G 2.5 + 2 x (2 x 1.5) 4G 4 + 2 x (2 x 1.5) 4G 6 + 2 x (2 x 1.5) 4G 10 + 2 x (2 x 1.5) 4G 16 + 2 x (2 x 1.5) 4G 25 + 2 x (2 x 1.5) 4G 35 + 2 x (2 x 1.5) 4G 50 + 2 x (2 x 2.5) 4G 1.5 + (2 x 1.5) 4G 2.5 + (2 x 1.5) 4G 4 + (2 x 1.5) 4G 6 + (2 x 1.5) 4G 10 + (2 x 1.5) 4G 16 + (2 x 1.5) 4G 25 + (2 x 1.5) 4G 35 + (2 x 1.5) 4G 50 + (2 x 1.5)

172 286 342 376 447 567 664 893 1298 1784 2588 3348 233 290 376 461 739 1123 1451 1919 2852

O/D mm

11.1 12.1 12.2 12.3 15.1 17.9 18.2 21.9 26.9 29.2 32.7 37.1 12.1 12.9 14.5 17.8 20.6 23.6 cables 28.1 32.1 35.3

FS

FS

FS

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

Cores x mm²

cables

275007403 275010407 275015405 275015407 275025415 275040415 275060415 275100414 275160415 275250415 275350415 275500425 275015215 275025215 275040215 275060215 275100215 275160215 275250215 275350215 275500215

Temperature Rating: Bending Radius:

275025415

cables


130

HIGH TEMPERATURE Silicone Single Cores

Silicone SiF, SiF-GL, SiD Singles N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Silicone insulated conductors offer you an economical solution to many temperature related wiring problems. Capable of working at extremes as far apart as -50°C right up to +180°C, silicone insulated cables have grown substantially in popularity. Flexibility is retained even at very low temperatures where conventional rubber or PVC cable would become brittle and crack. At high temperatures the cable performs normally. In the case of a fire, the silicone changes to form an insulating layer of SiO2 which, provided there is no movement, will maintain cable integrity in the short term. This is important in the event of a fire where equipment needs to be shut down, lighting maintained and alarm systems remain operational. Silicone is relatively inert, that is to say it gives off minimal smoke or fumes when exposed to fire. Airports, hospitals, and other public buildings use silicone cables to wire alarm, lighting, and other essential services. At high temperatures, applications include heating elements, lighting, manufacturing and food processing and for control circuits where heat is involved. At low temperatures silicone insulated cables are used in cold stores and refrigeration plants for lighting, portable equipment and motor feeds.

Technical Information Voltage Rating:

Working

300/500V

Test

2000V

Temperature Rating:

Flexing

-25°C to +180°C

Static

-50°C to +180°C

Static

-50°C to +180°C

SiD Bending Radius:

Flexing

SiF

15 x cable diameter

SiD

Static

7.5 x cable diameter

Static

7.5 x cable diameter

Current Rating:

Refer to IEE Regs Table 4F2A&B

Conductor Stranding:

Flexible cables

To IEC 60228 Class 5 & VDE 0295 Class 5

SiD

To IEC 60228 Class 1 & VDE 0295 Class 1

Most of the silicone insulated cables on the following page are available from stock in standard pack sizes of 100m or 500m. For conductor sizes above 10mm2 the cable can be cut to the length you require. Other voltages, strandings and approvals available on request. Construction - SiF cables

FS

FS cables

cables

FS

FS cables

Fine tinned copper wire strands, class 5, silicone insulation. Part No.

mm²

Weight kg/km

O/D mm

Part No.

mm²

Weight kg/km

451002xx

0.25

5

1.9

451350xx

35

399

10.9

451005xx

0.50

8

2.1

451500xx

50

559

12.6

451007xx

0.75

11

2.4

451700xx

70

766

14.6

451010xx

1.0

13

2.5

451950xx

95

1032

17.5

451015xx

1.5

18

2.8

451120xx

120

1285

18.7

451025xx

2.5

30

3.4

451150xx

150

1565

20.8

451040xx

4.0

48

4.2

451185xx

185

1915

23.7

451060xx

6.0

71

4.9

451240xx

240

2550

26.9

451100xx

10

120

6.7

451300xx

300

3190

30.1

451160xx

16

187

7.7

451400xx

400

4130

36.3

451250xx

25

289

9.8

451510xx

500

5210

40.3

www.fscables.com

sales@fscables.com

O/D mm


Silicone Single Cores HIGH TEMPERATURE

131

Construction - SiD Solid tinned copper wire strands, class 1, silicone insulation. Part No.

mm²

Weight kg/km

O/D mm

Part No.

mm²

Weight kg/km

O/D mm

441005xx 441007xx

0.50

7

1.8

441015xx

1.5

19

2.6

0.75

10

2.0

441025xx

2.5

31

3.2

441010xx

1.0

13

2.1

441040xx

4.0

48

3.7

441060xx

6.0

68

4.2

SiD

Construction - SiF-GL Fine tinned copper wire strands, class 5, silicone insulation. Impregnated glass fibre braid. Various colours. Part No.

mm²

Weight kg/km

O/D mm

Part No.

mm²

46100204 46100504

Weight kg/km

O/D mm

0.25

8

2.4

46106004

0.50

13

3.4

46110004

6.0

80

6.2

10

130

461007xx

0.75

16

3.6

8.2

46116004

16

200

461010xx

1.0

19

9.6

3.8

46125004

25

310

12.0

461015xx

1.5

461025xx

2.5

24

4.3

46135004

35

420

13.5

36

5.0

46150004

50

580

46104004

4.0

15.5

55

5.6

46170004

70

790

18.0

46195004

95

1070

20.0

Construction - SiF-HT Flexible tinned copper wire strands, class 5, silicone high voltage insulation. Part No.

mm²

Volts kV

O/D mm

SiF-GL

Colour

45201000

1.0

7.5

5.0

Red

45501004

1.0

10

7.0

White

Construction - SiF-G-Si-HT

Part No.

mm²

FS

FS

FS

cables

FS

FS

FS

FS

FS

Volts kV

O/D mm

Colour

45601000

1.0

16

8.0

Blue

45601500

1.5

16

8.5

Blue

cables

silicone sheath.

cables

Flexible tinned copper wire strands, class 5, silicone high voltage insulation, glass fibre braid, blue

cables

To show the colour required please replace xx in the part number with: 04

White

08

Orange

Blue

05

Grey

09

Yellow

02

Brown

06

Violet

10

Green

03

Red

07

Pink

99

Green/Yellow

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables

Black

01

cables

00

cables


132

HIGH TEMPERATURE Silicone Multicores

Silicone SiHF, SiHFP, SiHF-C-Si Multicores N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Silicone insulated and sheathed multicore cables offer electrical engineers and specifiers a superb range of options. Ideally suited to high or low temperature applications, these cables will work between -50°C and +180°C. When exposed to fire they produce minimal smoke or fumes and can be used to wire public buildings. Options include a galvanised steel wire braid for mechanical protection or a tinned copper wire braid for screening against EMI. Applications within industry include plastic forming and moulding, packaging, food processing, refrigeration, furnaces and lighting.

Technical Information

47101503

Voltage Rating:

Working

300/500V

Test

3000V

Temperature Rating:

Flexing

-25°C to +180°C

Static

-50°C to +180°C

Bending Radius SiHF:

Flexing

15 x cable diameter

Static

7.5 x cable diameter

Braided Cables:

Flexing

20 x cable diameter

Static

10 x cable diameter

Current Rating:

Refer to IEE Regs Table 4F2A&B and 4F3A&B

Conductor Stranding:

To IEC 60228 Class 5 & VDE 0295 Class 5

Construction - SiHF Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone rubber outer sheath. (Some sizes available with black or white sheaths or an overall glass fibre braid).

cables

FS

FS cables

cables

FS

Part No.

Cores x mm²

O/D mm

Part No.

Cores x mm²

O/D mm

47100702 47100703

2 x 0.75*

6.3

3 x 0.75*

7.0

47100704

4 x 0.75

7.7

47100705

5 x 0.75

8.5

47101002

2 x 1.0

7.0

47101003

3 x 1.0*

7.5

47101004

4 x 1.0

8.0

47101005

5 x 1.0

9.0

47101006

6 x 1.0

10.5

47101007

7 x 1.0

10.5

47101502

2 x 1.5

8.0

47101503

3 x 1.5*

8.5

47101504

4 x 1.5

9.0

47101505

5 x 1.5

10.0

47101506

6 x 1.5

10.5

47101507

7 x 1.5

10.5

47101508

8 x 1.5

12.0

47101510

10 x 1.5

14.5

47101512

12 x 1.5

16.0

47101516

16 x 1.5

19.5

47101518

18 x 1.5

20.0

47101520 47101524 47102502 47102503 47102504 47102505 47102507 47102512 47104002 47104003 47104004 47104005 47104007 47106002 47106003 47106004 47106005 47106007 47110004 47116004 47125004 47135004

20 x 1.5 24 x 1.5 2 x 2.5 3 x 2.5* 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 2 x 4.0 3 x 4.0 4 x 4.0 5 x 4.0 7 x 4.0 2 x 6.0 3 x 6.0 4 x 6.0 5 x 6.0 7 x 6.0 4 x 10 4 x 16 4 x 25 4 x 35

21.0 23.0 9.5 10.5 11.5 13.0 14.0 19.0 11.0 11.5 13.0 14.5 16.0 12.0 13.0 14.0 16.0 17.5 20.0 22.0 28.0 30.2

* Also available from stock with a black or white sheath

FS cables

www.fscables.com

sales@fscables.com


133

Silicone Multicores HIGH TEMPERATURE Construction - SiHFP Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone rubber sheath. Glass fibre tape with an overall galvanised steel wire braid. Part No.

Steel Braid Armour 48100702 48100703 48100704 48100705 48100706 48100707 48101002 48101003 48101004 48101005 48101006 48101007 48101502 48101503 48101504 48101505 48101506 48101507 48101508 48101510 48101512 48101516

Cores x mm²

O/D mm

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 6 x 0.75 7 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 6 x 1.0 7 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 6 x 1.5 7 x 1.5 8 x 1.5 10 x 1.5 12 x 1.5 16 x 1.5

8.0 8.5 9.5 10.0 11.0 11.0 8.5 9.0 10.0 10.5 11.5 11.5 9.0 9.5 11.0 12.0 13.0 13.0 14.5 16.0 17.5 21.0

Part No.

Cores x mm²

O/D mm

48101518

18 x 1.5

21.5

48101520

20 x 1.5

22.5

48101524

24 x 1.5

24.5

48102502

2 x 2.5

11.0

48102503

3 x 2.5

12.0

48102504

4 x 2.5

13.0

48102505

5 x 2.5

14.5

48102507

7 x 2.5

15.5

48102512

12 x 2.5

20.5

48104002

2 x 4.0

12.5

48104003

3 x 4.0

13.0

48104004

4 x 4.0

14.5

48104005

5 x 4.0

16.0

48104007

7 x 4.0

17.5

48106002

2 x 6.0

13.5

48106003

3 x 6.0

14.5

48106004

4 x 6.0

15.5

48106005

5 x 6.0

17.5

48106007

7 x 6.0

19.0

48110004

4 x 10

21.5

48116004

4 x 16

23.5

48125004

4 x 25

30.0

48102504E

Construction - SiHF-C-Si Fine tinned copper wire strands with silicone rubber insulation. Cores twisted together. Reddish brown silicone

Cores x mm²

O/D mm

Copper Braid Screen

FS

Part No.

Cores x mm²

O/D mm

49101502

2 x 1.5

10.6

49100702

2 x 0.75

9.1

49101503

3 x 1.5

11.0

49100703

3 x 0.75

9.5

49101504

4 x 1.5

11.9

49100704

4 x 0.75

10.1

49101505

5 x 1.5

13.2

49100705

5 x 0.75

10.7

49101507

7 x 1.5

14.2 cables

49100707

7 x 0.75

11.6

49101512

12 x 1.5

18.0

49100712

12 x 0.75

14.8

49102502

2 x 2.5

12.0

49101002

2x1

9.4

49102503

3 x 2.5

12.9

49101003

3x1

9.7

49102504

4 x 2.5

14.2

49101004

4x1

10.3

49102505

5 x 2.5

15.4

49101005

5x1

11.2

49102507

7 x 2.5

16.8

49101007

7x1

11.9

cables

FS

FS

FS

cables

cables

Fax : 01727 840 842

FS

FS

cables

Tel: 01727 840 841

FS

FS

cables

Part No.

cables

rubber inner sheath or polyester tape. Tinned copper wire braid. Reddish brown silicone rubber sheath.

cables


134

HIGH TEMPERATURE PTFE Single Cores

PTFE Single Cores BSXLPE/Cu/LSHF 3G 210 N2XCH-FE180/E90: Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV These cables are manufactured to BS 3G 210 and operate up to +200°C or +250°C short term with silver plated copper conductors. Nickel plated conductor versions to work up to +260°C are available to special order. Other standards available include American Mil, VDE, DIN and Lloyds. PTFE is a remarkable material. It is unaffected by most oils, fuels and fluids. The high temperature range makes it resistant to damage from heat sources such as soldering irons or components. Multicore and screened or braid armoured versions can also be manufactured in many sizes and styles. Please note due to the manufacturing process this cable may be supplied in multiple lengths on a reel. For example 100m may be made up of two or more lengths.

Technical Information Voltage Rating:

BSG31819B01

Working

Type A

300V

Type B

600V

Test: 3400V

Type C

1000V

Test: 5000V

Short term

+250°C

Temperature Rating:

Static

-55°C to +200°C

Bending Radius:

Static

6 x cable diameter

Conductor Material:

Test: 2500V

Silver plated copper

Manufactured to BS 3G 210. See page 131 for colour code table. Part No.

cables

FS

BSG31419C04

FS cables

cables

FS

FS cables

AWG

Stranding mm

CSA mm2

Voltage Grade

Weight kg/km

min

O/D mm max

BSG33007Axx

30

7/0.10

0.056

A

1.1

0.50

BSG32807Axx

28

7/0.12

0.089

A

1.4

0.56

0.65 0.71

BSG32807Bxx

28

7/0.12

0.089

B

2.1

0.76

0.96 0.80

BSG32607Axx

26

7/0.15

0.14

A

1.7

0.65

BSG32607Bxx

26

7/0.15

0.14

B

3.09

0.85

1.05

BSG32407Axx

24

7/0.20

0.22

A

3.04

0.80

0.95

BSG32407Bxx

24

7/0.20

0.22

B

3.89

1.00

1.20

BSG32407Cxx

24

7/0.20

0.22

C

4.64

1.26

1.52

BSG32219Axx

22

19/0.15

0.35

A

4.41

0.95

1.10

BSG32219Bxx

22

19/0.15

0.35

B

5.44

1.15

1.35

BSG32219Cxx

22

19/0.15

0.35

C

6.43

1.41

1.67

BSG32019Axx

20

19/0.20

0.61

A

7.19

1.20

1.35

BSG32019Bxx

20

19/0.20

0.61

B

8.43

1.40

1.60

BSG32019Cxx

20

19/0.20

0.61

C

9.08

1.66

1.92

BSG31819Bxx

18

19/0.25

0.96

B

12.1

1.65

1.85

BSG31819Cxx

18

19/0.25

0.96

C

14.3

1.91

2.17

BSG31619Cxx

16

19/0.30

1.23

C

16.5

2.16

2.46

BSG31419Cxx

14

19/0.36

1.94

C

23.9

2.34

2.74

BSG31219Cxx

12

19/0.45

3.08

C

38.5

2.91

3.31

BSG31037Cxx

10

37/0.40

4.65

C

56

3.46

3.86

www.fscables.com

sales@fscables.com


135

P-Temp 260 HIGH TEMPERATURE P-Temp 260 P-Temp-260 cables are designed to operate at conductor temperatures up to +260°C. The PTFE insulation is covered by a layer of mica that is protected from abrasion or mechanical damage by an impregnated and varnished glass fibre braid. The cable is also capable of withstanding higher temperatures for short periods. This is a direct alternative to In-Temp 250 that used to be manufactured by BICC.

76010000

The fine stranded nickel plated copper conductor provides flexibility during installation and routing with substantially improved high temperature performance over tinned or plain copper. Multicore versions can be made to your requirements normally with stainless steel or glass fibre braids. Other types of PTFE insulated wires are also available with tinned, nickel, or silver plated conductors. Please ask for details.

Construction

Technical Information

Fine nickel plated copper wire strands

Voltage Rating:

Working 0.6/1kV Test 5000V

to IEC 60228 Class 5 or finer. White PTFE insulation. Mica tape, impregnated

Temperature Rating:

Static -55°C to +260°C

and varnished glass fibre braid. Standard

Bending Radius:

Static 10 x cable diameter

colour white, other colours to special

Conductor Stranding:

To IEC 60228 class 5 flexible or finer

order.

Part No.

CSA mm2

Stranding x mm

Weight kg/km

O/D mm

Current amps*

76001000

1.0

32 x 0.2

22

3.2

25

76001500

1.5

30 x 0.25

30

3.6

40

76002500

2.5

50 x 0.25

39

3.9

54

76004000

4.0

56 x 0.3

56

4.7

74

76006000

6.0

84 x 0.3

80

6.1

98

76010000

10

133 x 0.3

120

6.9

135

76016000

16

126 x 0.4

193

8.7

180

76025000

25

196 x 0.4

287

10.2

240

cables

FS

FS

FS

cables

FS

cables

cables

cables

Up to 25mm2 held in stock.

FS

cables

*Current rating at +80°C ambient for conductor temperature of +250°C.

FS

We also hold stocks of some sizes of Unipren, Uniefglas, Uniminyvin, Uninyvin and Unitersil. Please ask for details.

Tel: 01727 840 841

Fax : 01727 840 842

FS

cables

FS cables


136

HIGH TEMPERATURE G-Temp 600

G-Temp 600 N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Pure nickel conductors offer excellent high temperature performance. The conductor can withstand temperatures up to +750°C. The high temperature glass insulation enables the nickel conductor to operate continuously at +600°C and for short periods up to +750°C. Applications include furnaces, ovens, kilns and other extremely high temperature environments. These cables can also be supplied in multicore versions with overall glass fibre or stainless steel braids for quantities as low as 100m. Higher voltages are available by special order. These include a mica tape in the cable construction. Please call if you have a specific requirement.

Technical Information

Construction Pure nickel strands, double glass yarn lapped,

Voltage Rating:

Working 250V

impregnated, glass braided, double silicone varnished,

Temperature Rating:

Continuous +600°C Intermittent +750°C

colour natural/white. Part No.

78504056

Nominal CSA mm2

Stranding x mm

Lug Type

Weight kg/km

O/D mm

Current ratings in Amps at +30°C Ambient. Conductor Temp. +180°C +200° +250°C

78500516

0.50

16/0.2

A

9

2.0

5

6

78500724

0.75

24/0.2

A

11

2.3

6

7

7.5 9

78501032

1.0

32/0.2

A

16

2.5

9

9

10

78501530

1.5

30/0.25

B

22

2.7

15

16

17

78502550

2.5

50/0.25

B

32

3.3

21

22

23

78504056

4.0

56/0.3

C

46

3.9

26

28

29

78506084

6.0

84/0.3

C

59

5.2

31

33

34

Nickel Crimp Lugs cables

FS

Copper is not suitable for crimp lugs at very high temperatures due to its greater expansion rate. This can result in nickel conductors simply dropping out. We are able to offer high temperature stable crimp lugs that will work at over +800ºC suitable for use on FSC G-Temp-600.

FS cables

Part No.

Lug Type

Conductor Size Min Max

Stud Size

Max Length

Max Width

LUGN02/1/4

A

0.25mm2

1.0mm2

4mm

14.8

6.8

LUGN10/2/4

B

1.0mm2

2.5mm2

4mm

16.4

8.3

LUGN20/6/4

C

2.5mm2

6.0mm2

4mm

20.0

9.9

cables

FS

FS cables

www.fscables.com

sales@fscables.com


137

318*TQ Heat Resistant Flex HIGH TEMPERATURE 318*TQ Heat Resistant Flex TQ flex is suitable for use on heat resistant applications ranging from lighting to central heating systems and immersion heaters. With colour coloured cores and rated at 85째C this cable is ideal as a power supply lead or a control cable where ambient temperatures exceed the working range of standard PVC cables. The EPR insulation and CSP jacket result in a highly flexible yet tough cable.

Construction

Technical Information

Stranded copper conductors to IEC

Voltage Rating:

300/500V

60228 Class 5, ethylene propylene

Conductor Stranding:

Stranded. IEC 60228 class 5

rubber (EPR, T) insulation colour coded.

Temperature Rating:

-20째c to +85째c

Cores laid up, white chlorosulphonated

Bending Radius:

6 x overall diameter

57101504TQ

polyethylene (CSP, Q) jacket Normally packed on 50m or 100m reels longer lengths may be available. Part No.

Cores x mm2

Weight kg/km

O/D mm

57100702TQ

2 x 0.75

65

6.6

57100703TQ

3 x 0.75

80

7.3

57100704TQ

4 x 0.75

95

7.8

80

7.3

95

7.8

57101004TQ

4 x 1.0

115

8.3

57101502TQ

2 x 1.5

120

8.8

57101503TQ

3 x 1.5

140

9.5

57101504TQ

4 x 1.5

175

10.5

57102502TQ

2 x 2.5

170

10.3

57102503TQ

3 x 2.5

200

11.0

57102504TQ

4 x 2.5

250

12.2

FS

FS

cables

2 x 1.0 3 x 1.0

cables

57101002TQ 57101003TQ

Motorised Valve Extension Cable Ideal for extending the cables on motorised valves on heating systems. Using heat resistant 90째C PVC these cables make connecting up zoned systems simple. The colour code emulates the one used on popular motorised valves.

FS

cables

Construction

FS cables

Stranded copper conductors IEC 60228 class 5, PVC insulation, colour coded. Cores laid up, black heat resistant PVC jacket. Weight kg/km

O/D mm

10000706MV

6 x 0.75

81

6.9

Colour Code: Blue

Brown

Grey

Orange

FS

FS

FS

FS

cables

Cores x mm2

cables

Part No.

Green/Yellow White

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


138

THERMOCOUPLE Thermocouple Cables

Thermocouple Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV Thermocouple cables are used to carry a signal from a thermocouple probe to the temperature measuring unit and are made up of a screened positive and negative (orscreening leg) of different metals whichinare same similar those the Fire resistant power cablesconductor provide EMI and circuit integrity thethe event of aorfire. Theyasare idealinfor thermocouple probe. applications such as fire pumps and ventilation systems in office blocks where electrical interference needs keeping to a minimum duringreferred normal to operation and services must be maintained evacuation during a fire situation. The cables meet While commonly as thermocouple cables, most cables are infor fact ‘extension’ or ‘compensating’ cables. IEC 60331 and are fire resistant for 3 hours at 750°C. Extension cables are manufactured with the same metals as the thermocouple probe. Due to the expense of extension cables, compensating often usedpart in their place provideon accurate E30 System integrity cables cables are to DIN 4102 12 are alsoand available request.results over a more limited operating range. As with any other instrumentation or measuring application it can be beneficial to have multiple numbers of pairs. Triples are also available to meet specialist applications. Interference (EMI) is also something to consider and screening, either individually around each pair or collectively around a multi pair is an option. If the cable is likely to suffer mechanical damage or be buried in the ground armouring (SWA) is also available. Cables installed in sensitive locations such as power stations Low Smoke Halogen Free thermocouple cables may be required.

International Colour Codes for Thermocouple Cable Insulation

Cable Type

EUROPEAN BS 4937 Part 30

BRITISH BS 1843

AMERICAN ANSI MC96.1

GERMAN DIN 43710.4

Extension Cables

cables

FS

FS

KX

+ –

+ –

+ –

+ –

JX

+ –

+ –

+ –

+ –

TX

+ –

+ –

+ –

+ –

EX

+ –

+ –

+ –

+ –

NX

+ –

+ –

+ –

+ –

+ –

+ –

+ –

+ –

+ –

+ –

+ –

+ –

Compensating Cables

cables

KCB

Compensation for Type K (was Vx)

RCA/SCA cables

FS

FS cables

Compensation for Type R or S

www.fscables.com

sales@fscables.com


139

Thermocouple Cables THERMOCOUPLE Part No.

Conductor Type

No. of Pairs

Conductor Size

Screening Type

Insulation Material

Sheath Material

1 1 1 1 1 1 1 1

7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm

Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened

PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC

KCB KCB KCB KCB KCB KCB KCB KCB

1 1 1 1 1 1 1 1

7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm

Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened

PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC

TKXO0201 TKXU0201 TKXO0401 TKXU0401 TKXO0502H TKXO0701 TKXU0701 TKXO1501 TKXU1501

KX KX KX KX KX KX KX KX KX

1 1 1 1 1 1 1 1 1

7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 16/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm

Overall Foil Unscreened Overall Foil Unscreened Overall Braid Overall Foil Unscreened Overall Foil Unscreened

PVC PVC PVC PVC LSHF PVC PVC PVC PVC

PVC PVC PVC PVC LSHF PVC PVC PVC PVC

TNXO0201 TNXU0201 TNXO0401 TNXU0401 TNXO0701 TNXU0701 TNXO1501 TNXU1501

NX NX NX NX NX NX NX NX

1 1 1 1 1 1 1 1

7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm

Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened

PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC

TRCO0201 TRCU0201 TRCO0401 TRCU0401 TRCO0701 TRCU0701 TRCO1501 TRCU1501

RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA

1 1 1 1 1 1 1 1

7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm

Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened

PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC

TTXO0201 TTXU0201 TTXO0401 TTXU0401 TTXO0701 TTXU0701 TTXO1501 TTXU1501

TX TX TX TX TX TX TX TX

1 1 1 1 1 1 1 1

7/0.2mm 7/0.2mm 13/0.2mm 13/0.2mm 23/0.2mm 23/0.2mm 1/1.29mm 1/1.29mm

Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened Overall Foil Unscreened

Screened & Unscreened Single Pairs TJXO0201 JX TJXU0201 JX TJXO0401 JX TJXU0401 JX TJXO0701 JX TJXU0701 JX TJXO1501 JX TJXU1501 JX TKCO0201 TKCU0201 TKCO0401 TKCU0401 TKCO0701 TKCU0701 TKCO1501 TKCU1501

PVC

PVC cables

FS

FS

cables

FS

PVC PVC cables PVC PVC PVC PVC PVC PVC

FS

cables

PVC PVC PVC PVC PVC PVC

FS

cables

Fax : 01727 840 842

FS

cables

Tel: 01727 840 841

cables

*Please note all the above cables are European Colour Coded.

FS

FS cables


140

THERMOCOUPLE Thermocouple Cables

Individually and Collectively Foil Screened Multipairs, PVC, Armoured & Unarmoured Construction - Unarmoured

Construction - Armoured

Conductors insulated in PVC, cores laid up to form a pair,

Conductors insulated in PVC, cores laid up to form a pair, each pair

each pair individually foil screened with drain wire, pairs laid

individually foil screened with drain wire, pairs laid up, overall foil screen

up, overall foil screen with drain wire, PVC outer sheath.

with drain wire, PVC bedding, steel wire armour, PVC outer sheath.

TTXO0505A

cables

FS

FS cables

cables

FS

FS cables

Part No. Unarmoured

Conductor Type

No. of Pairs

Conductor Size mm2

Screening Type

Insulation Material

Sheath Material

Part No. Armoured

TJXI0502 TJXI0504 TJXI0506 TJXI0512 TJXI0516 TJXI0520 TJXI0524 TJXI0702 TJXI0704 TJXI0706 TJXI0712 TJXI0716 TJXI0720 TJXI0724

JX JX JX JX JX JX JX JX JX JX JX JX JX JX

2 4 6 12 16 20 24 2 4 6 12 16 20 24

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75

Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

TJXI0502A TJXI0504A TJXI0506A TJXI0512A TJXI0516A TJXI0520A TJXI0524A TJXI0702A TJXI0704A TJXI0706A TJXI0712A TJXI0716A TJXI0720A TJXI0724A

TKXI0502 TKXI0504 TKXI0506 TKXI0512 TKXI0516 TKXI0520 TKXI0524 TKXI0702 TKXI0704 TKXI0706 TKXI0712 TKXI0716 TKXI0720 TKXI0724

KX KX KX KX KX KX KX KX KX KX KX KX KX KX

2 4 6 12 16 20 24 2 4 6 12 16 20 24

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75

Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

TKXI0502A TKXI0504A TKXI0506A TKXI0512A TKXI0516A TKXI0520A TKXI0524A TKXI0702A TKXI0704A TKXI0706A TKXI0712A TKXI0716A TKXI0720A TKXI0724A

TKCI0502 TKCI0504 TKCI0506 TKCI0512 TKCI0516 TKCI0520 TKCI0524 TKCI0702 TKCI0704 TKCI0706 TKCI0712 TKCI0716 TKCI0720 TKCI0724

KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB KCB

2 4 6 12 16 20 24 2 4 6 12 16 20 24

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75

Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

TKCI0502A TKCI0504A TKCI0506A TKCI0512A TKCI0516A TKCI0520A TKCI0524A TKCI0702A TKCI0704A TKCI0706A TKCI0712A TKCI0716A TKCI0720A TKCI0724A

TNXI0502 TNXI0504 TNXI0506 TNXI0512 TNXI0516 TNXI0520 TNXI0524 TNXI0702 TNXI0704 TNXI0706 TNXI0712 TNXI0716 TNXI0720 TNXI0724

NX NX NX NX NX NX NX NX NX NX NX NX NX NX

2 4 6 12 16 20 24 2 4 6 12 16 20 24

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75

Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

TNXI0502A TNXI0504A TNXI0506A TNXI0512A TNXI0516A TNXI0520A TNXI0524A TNXI0702A TNXI0704A TNXI0706A TNXI0712A TNXI0716A TNXI0720A TNXI0724A

www.fscables.com

sales@fscables.com


141

Thermocouple Cables THERMOCOUPLE Part No. Unarmoured

Conductor Type

No. of Pairs

Conductor Size mm2

Screening Type

Insulation Material

Sheath Material

Part No. Armoured

TRCI0502 TRCI0504 TRCI0506 TRCI0512 TRCI0516 TRCI0520 TRCI0524 TRCI0702 TRCI0704 TRCI0706 TRCI0712 TRCI0716 TRCI0720 TRCI0724

RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA RCA/SCA

2 4 6 12 16 20 24 2 4 6 12 16 20 24

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75

Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

TRCI0502A TRCI0504A TRCI0506A TRCI0512A TRCI0516A TRCI0520A TRCI0524A TRCI0702A TRCI0704A TRCI0706A TRCI0712A TRCI0716A TRCI0720A TRCI0724A

TTXI0502 TTXI0504 TTXI0506 TTXI0512 TTXI0516 TTXI0520 TTXI0524 TTXI0702 TTXI0704 TTXI0706 TTXI0712 TTXI0716 TTXI0720 TTXI0724

TX TX TX TX TX TX TX TX TX TX TX TX TX TX

2 4 6 12 16 20 24 2 4 6 12 16 20 24

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75

Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil Ind & Overall Foil

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC

TTXI0502A TTXI0504A TTXI0506A TTXI0512A TTXI0516A TTXI0520A TTXI0524A TTXI0702A TTXI0704A TTXI0706A TTXI0712A TTXI0716A TTXI0720A TTXI0724A

*For Halogen Free versions please add an H to the end of the part number. These will generally be supplied with XLPE insulation and a LSHF sheath. Please note all the above cables are European Colour Coded

Screened Single pairs, LSHF Fire Resistant, Armoured & Unarmoured Construction - Unarmoured

Construction - Armoured

Conductors stranded and mica taped, XLPE insulated, cores

Conductors stranded and mica taped, XLPE insulated, cores twisted to form a pair, overall foil screen with drain wire, LSHF bedding, steel wire armour, LSHF outer sheath.

twisted to form a pair, overall foil screen with drain wire,

Conductor Type

No. of Pairs

Conductor Size mm2

Screening Type

Insulation Material

TJXO0501M TJXO0701M

JX JX

1 1

0.5 0.75

Overall Foil Overall Foil

XLPE XLPE

TKCO0501M TKCO0701M

KCB KCB

1 1

0.5 0.75

Overall Foil Overall Foil

XLPE XLPE

TKXO0501M TKXO0701M

KX KX

1 1

0.5 0.75

Overall Foil Overall Foil

XLPE XLPE

TNXO0501M TNXO0701M

NX NX

1 1

0.5 0.75

Overall Foil Overall Foil

TRCO0501M TRCO0701M

RCA/SCA RCA/SCA

1 1

0.5 0.75

TTXO0501M TTXO0701M

TX TX

1 1

0.5 0.75

FS

Sheath Material

Part No. Armoured

LSHF LSHF

TJXO0501AM TJXO0701AM

LSHF LSHF

TKCO0501AM TKCO0701AM

FS

cables LSHF

FS

LSHF

cables TKXO0501AM TKXO0701AM

XLPE XLPE

LSHF LSHF

TNXO0501AM TNXO0701AM

Overall Foil Overall Foil

XLPE XLPE

LSHF LSHF

TRCO0501AM TRCO0701AM

Overall Foil Overall Foil

XLPE XLPE

FS

LSHF LSHF

TTXO0501AM TTXO0701AM

FS

cables

FS

cables

Fax : 01727 840 842

cables

Tel: 01727 840 841

FS

cables

Part No. Unarmoured

cables

LSHF outer sheath.

FS cables


142

SPIRAL Spiral Cables

Spiral Cables N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) LSHF Power Cable – 0.6/1kV

FSC offers both signal and power versions of retractable spiral cables. The variations in conductor size, insulation and sheath materials are enormous. Having decided on the conductor size and the number of cores it is important to choose the insulation and sheath materials most suitable for the task. The retracted length of the spiral can be made to your requirements up to 5m. Although once popular, PVC is now giving way to polyurethane as a sheathing material which has a much better memory. Rubber is still popular with hytral used for the highest performance cables. The sizes and types shown on the page opposite are a small selection of the spiral cables offered. There are many other sheathing, insulation materials and voltage ratings as well as screened versions available. Please call with your exact requirement. These cables are manufactured to order, to meet your needs precisely. You can specify tail lengths (the straights at either end). The standard length is at least 150mm and they can be supplied in line or at right angles to the coil. Delivery is normally around 10 working days but please check when ordering. Many other core combinations are available. Please call to discuss your requirements.

Spiral Cable

Construction - PVC Spiral Cable

Technical Information

Fine copper wire strands. PVC insulation, colour coded cores, twisted together, PVC jacket.

Voltage Rating: Working 300/500V Temperature Rating: -5°C to +70°C Approximate Extension Ratio: 3.5:1

Part No.

PVC Spirals 88200702 88200703 88200704 88200705 88201002

cables

FS

cables

cables

FS

FS cables

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.0

Part No.

Cores x mm²

Part No.

Cores x mm²

88201003 88201004 88201005 88201502 88201503 88201504

3 x 1.0 4 x 1.0 5 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5

88201505 88202502 88202503 88202504 88202505

5 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5

Construction: PUR Screened Spiral Cable

Technical Information

Fine copper wire strands of class 5 or 6. TPE insulation, colour coded cores, twisted together, overall tinned copper wire braid, PUR jacket.

Working ≤0.25mm² 100V ≥ 0.5mm² 300V Temperature Rating: -25°C to +80°C Approximate Extension Ratio: 4:1

Part No.

FS

Cores x mm²

Cores x mm²

PUR Screened Spirals 88300102 2 x 0.14 88300103 3 x 0.14 88300104 4 x 0.14 88300105 5 x 0.14 88300106 6 x 0.14 88300107 7 x 0.14 88300108 8 x 0.14 88300112 12 x 0.14 88300118 18 x 0.14 88300125 25 x 0.14

Voltage Rating:

Part No.

Cores x mm²

Part No.

Cores x mm²

88300202 88300203 88300204 88300205 88300206 88300207 88300208 88300212 88300218 88300225

2 x 0.25 3 x 0.25 4 x 0.25 5 x 0.25 6 x 0.25 7 x 0.25 8 x 0.25 12 x 0.25 18 x 0.25 25 x 0.25

88300503 88300504 88300505 88300506 88300507 88300508 88300512 88300518 88300525

3 x 0.5 4 x 0.5 5 x 0.5 6 x 0.5 7 x 0.5 8 x 0.5 12 x 0.5 18 x 0.5 25 x 0.5

www.fscables.com

sales@fscables.com


143

Spiral Cables SPIRAL Construction: PUR Spiral Cable

Technical Information

Fine copper wire strands of class 5 or 6. TPE or EPR insulation, colour coded cores, twisted together, PUR jacket.

Voltage Rating: Temperature Rating: Approximate Extension Ratio:

Part No.

Cores x mm²

PUR Unscreened Spirals 88100102 2 x 0.14 88100103 3 x 0.14 88100104 4 x 0.14 88100105 5 x 0.14 88100106 6 x 0.14 88100107 7 x 0.14 88100108 8 x 0.14 88100110 10 x 0.14 88100112 12 x 0.14 88100116 16 x 0.14 88100125 25 x 0.14 88100202 2 x 0.25 88100203 3 x 0.25 88100204 4 x 0.25

Part No.

Cores x mm²

88100205 88100206 88100207 88100208 88100210 88100212 88100216 88100225 88100502 88100503 88100504 88100505 88100506 88100507 88100508

5 x 0.25 6 x 0.25 7 x 0.25 8 x 0.25 10 x 0.25 12 x 0.25 16 x 0.25 25 x 0.25 2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 6 x 0.5 7 x 0.5 8 x 0.5

Part No.

Cores x mm²

88100510 88100512 88100516 88100525 88100702 88100703 88100704 88100705 88101002 88101003 88101004 88101005 88101007 88101012 88101502

Part No.

10 x 0.5 12 x 0.5 16 x 0.5 25 x 0.5 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 2 x 1.5

88101503 88101504 88101505 88101507 88101512 88102503 88102504 88102505 88104004 88104005 88106004

Construction: Rubber TPE Spiral Cable

Technical Information

Fine copper wire strands of class 5. Special PVC insulation, colour coded cores, twisted together, black TPE synthetic rubber jacket.

Voltage Rating: Temperature Rating: Approximate Extension Ratio:

Part No.

Cores x mm²

3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 3 x 2.5 4 x 2.5 5 x 2.5 4 x 4.0 5 x 4.0 4 x 6.0

Part No.

Cores x mm²

Part No.

Cores x mm²

88001005 88001007 88001010 88001015 88001502 88001503 88001504 88001505 88001507 88001510 88001515

5 x 1.0 7 x 1.0 10 x 1.0 15 x 1.0 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 10 x 1.5 15 x 1.5

88002502 88002503 88002504 88002505 88002507 88004003 88004004 88004005 88006003 88006004

2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 3 x 4.0 4 x 4.0 5 x 4.0 3 x 6.0 4 x 6.0

FS

LE LC

ST

FS

cables

2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 10 x 0.75 15 x 0.75 2 x 1.0 3 x 1.0 4 x 1.0

Cores x mm²

Working 300/500V -15°C to +80°C 5:1

cables

Rubber TPE Spirals 88000702 88000703 88000704 88000705 88000707 88000710 88000715 88001002 88001003 88001004

Working 300/500V -25°C to +85°C 4:1

FS

ST cables

FS

FS

FS

FS

FS

cables

DS

Length of ST straight tail

LE Length extended

DS Diameter of spiral

Length of tail RA at right angles

LC Length closed

DC

Tel: 01727 840 841

Fax : 01727 840 842

Diameter of cable

cables

cables

RA DC

cables

RA

cables


144

GLANDS Plastic & Brass Industrial

Industrial Glands XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV

FSC offers a range of high quality industrial cable glands manufactured in nylon and metal to meet industry requirements. Metal glands are available in a plain brass or with nickel plating. All the glands have at least one rubber seal to provide environmental protection and an IP (Ingress Protection) rating. To achieve the IP rating shown an additional washer may be required if the enclosure or panel is not threaded. If you are not sure please ask at time of enquiry. We can also supply gland kits complete with accessories, please add a K to the end of the part number. Aluminium glands for terminating AWA type armours and stainless steel glands for specialist applications are also available. A2 nickel plated brass glands for unarmoured cables IP68 rated indoor/outdoor glands with a single rubber seal on the cable sheath. -60°C to +150°C. Sometimes referred to as stuffing glands they are ideal for unarmoured or flexible cables. Part No.

A2

GA2M20SSN GA2M20SN GA2M20N GA2M25N GA2M32N GA2M40N GA2M50SN GA2M50N GA2M63SN GA2M63N GA2M75SN GA2M75N GA2M90N GA2M100N GA2M115N GA2M130N

Description

Thread ISO (mm)

Cable O/D Range (mm)

A2 20S/16 A2 20S A2 20 A2 25 A2 32 A2 40 A2 50S A2 50 A2 63S A2 63 A2 75S A2 75 A2 90 A2 100 A2 115 A2 130

20 20 20 25 32 40 50 50 63 63 75 75 90 100 115 130

3.1 - 8.7 6.1 - 11.7 6.5 - 14.0 11.1 - 20.0 17.0 - 26.3 23.5 - 32.2 31.0 - 38.2 35.6 - 44.1 41.5 - 50.0 47.2 - 56.0 54.0 - 62.0 61.1 - 68.0 66.6 - 79.4 76.0 - 91.0 86.0 - 98.0 97.0 - 115.0

Steel Locknut

GLSM20 GLSM20 GLSM20 GLSM25 GLSM32 GLSM40 GLSM50 GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130

CW nickel plated brass glands for SWA armoured cables Ideal for anchoring the steel wire armour (SWA) on power, data and instrumentation cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on the outer sheath of the cable. -60°C to +150°C.

CW cables

FS

FS cables

cables

FS

FS cables

Part No.

GCWM20SSN GCWM20SN GCWM20N GCWM25SN GCWM25N GCWM32N GCWM40N GCWM50SN GCWM50N GCWM63SN GCWM63N GCWM75S GCWM75N GCWM90N GCWM100N GCWM115N GCWM130N

Description

Thread ISO (mm)

Cable Bedding Diameter

Cable O/D Range (mm)

Steel Locknut

CW 20S/16 CW 20S CW 20 CW 25S CW 25 CW 32 CW 40 CW 50S CW 50 CW 63S CW 63 CW 75S CW 75 CW 90 CW 100 CW 115 CW 130

20 20 20 25 25 32 40 50 50 63 63 75 75 90 100 115 130

8.7 11.7 14.0 19.9 20.0 26.3 32.2 38.2 44.1 50.0 56.0 62.0 68.0 80.0 91.0 98.0 115.0

6.1 - 11.5 9.5 - 15.9 12.5 - 20.9 14.0 - 22.0 18.2 - 26.2 23.7 - 33.9 27.9 - 40.4 35.2 - 46.7 40.4 - 53.1 45.6 - 59.4 54.6 - 65.9 59.0 - 72.1 66.7 - 78.5 76.2 - 90.4 89.1 - 101.5 101.3 - 110.3 114.0 - 123.3

GLSM20 GLSM20 GLSM20 GLSM25 GLSM25 GLSM32 GLSM40 GLSM50 GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130

www.fscables.com

sales@fscables.com


145

Plastic & Brass Industrial GLANDS Industrial Glands XLPE/Cu/LSHF Screened, Fire Resistant (IEC N2XCH-FE180/E90: 60331)

Always use a gland with a maximum size closest to the diameter of the cable so the gland only has to compress a minimal amount. Reducers, enlargers and convertors are available to alter the gland thread size. These can be supplied in metal or plastic to fit pre threaded enclosures or equipment. Adaptors are also available to change one type of thread to another. Combinations include ISO metric, NPT and PG. CX nickel plated glands for braided cables and steel tape armoured cables Designed to secure braid armours and braid screens they can also be used for steel tape armours on fibre optic and instrumentation cables. IP66 rated indoor/outdoor glands that terminate the braid or tape and provide a seal on the cable sheath. -60째C to +150째C. Part No.

Description

Thread ISO (mm)

Cable Bedding Diameter

GCXM20SSN GCXM20SN GCXM20N GCXM25SN GCXM25N GCXM32N GCXM40N GCXM50SN GCXM50N GCXM63SN GCXM63N GCXM75SN GCXM75N GCXM90N GCXM100N GCXM115N GCXM130N

CX 20S/16 CX 20S CX 20 CX 25S CX 25 CX 32 CX 40 CX 50S CX 50 CX 63S CX 63 CX 75S CX 75 CX 90 CX 100 CX 115 CX 130

20 20 20 25 25 32 40 50 50 63 63 75 75 90 100 115 130

8.7 11.7 14.0 19.9 20.0 26.3 32.2 38.2 44.1 50.0 56.0 62.0 68.0 80.0 91.0 98.0 115.0

Cable O/D Range (mm)

6.1 - 11.5 9.5 - 15.9 12.5 - 20.9 14.0 - 22.0 18.2 - 26.2 23.7 - 33.9 27.9 - 40.4 35.2 - 46.7 40.4 - 53.1 45.6 - 59.4 54.6 - 65.9 59.0 - 72.1 66.7 - 78.5 76.2 - 90.4 89.1 - 101.5 101.3 - 110.3 114.0 - 123.3

Steel Locknut

GLSM20 GLSM20 GLSM20 GLSM25 GLSM25 GLSM32 GLSM40 GLSM50 GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130

CX

E1W dual seal nickel plated brass glands for SWA armoured cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on to the inner and outer sheath of the cable. -60째C to +150째C. Part No.

6.1 -11.5 9.5 -15.9 12.5 -20.9 14.0 -22.0 18.2 -26.2 23.7 -33.9 27.9 -40.4 35.2 -46.7 40.4 -53.1 45.6 -59.4 54.6 -65.9 59.0 -72.1 66.7 -78.5 76.2 -90.4 89.1 -101.5 101.3 -110.3 114.0 -123.3

Fax : 01727 840 842

Steel Locknut

E1W

FS

FS

FS

FS

FS

FS

FS

FS

GLSM20 GLSM20 GLSM20 GLSM25 GLSM25 GLSM32 GLSM40 GLSM50cables GLSM50 GLSM63 GLSM63 GLSM75 GLSM75 GLSM90 GLSM100 GLSM115 GLSM130

cables

cables

cables

Tel: 01727 840 841

3.1 -8.7 6.1 -11.7 6.5 -14.0 11.1 -19.9 11.1 -20.0 17.0 -26.3 22.0 -32.2 29.5 -38.2 35.6 -44.1 40.1 -50.0 47.2 -56.0 52.8 -62.0 59.1 -68.0 66.6 -80.0 76.0 -91.0 86.0 -98.0 97.0 -115.0

Cable O/D Range (mm)

cables

20 20 20 25 25 32 40 50 50 63 63 75 75 90 100 115 130

Cable Bedding Diameter

cables

E1W 20S/16 E1W 20S E1W 20 E1W 25S E1W 25 E1W 32 E1W 40 E1W 50S E1W 50 E1W 63S E1W 63 E1W 75S E1W 75 E1W 90 E1W 100 E1W 115 E1W 130

Thread ISO (mm)

cables

GE1WM20SSN GE1WM20SN GE1WM20N GE1WM25SN GE1WM25N GE1WM32N GE1WM40N GE1WM50SN GE1WM50N GE1WM63SN GE1WM63N GE1WM75SN GE1WM75N GE1WM90N GE1WM100N GE1WM115N GE1WM130N

Description

cables


146

GLANDS Plastic & Brass Industrial

Industrial Glands XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331) N2XCH-FE180/E90: LSHF Power Cable – 0.6/1kV

If the gland type you require is not shown or you need a specialist gland for a bespoke application please contact us and we will do our best to help you. E1X dual seal nickel plated brass glands for braid armoured cables IP66 rated indoor/outdoor glands that terminate the armour and provide a seal on to the inner and outer sheath of the cable. -60°C to +150°C. Part No.

E1X

Description

Thread ISO (mm)

Cable Bedding Diameter

Cable O/D Range (mm)

Steel Locknut

GE1XM20SS

E1X 20S/16

GE1XM20S

E1X 20S

20

3.1 - 8.7

6.1 - 11.5

GLSM20

20

6.1 - 11.7

9.5 - 15.9

GE1XM20

E1X 20

GLSM20

20

6.5 - 14.0

12.5 - 20.9

GLSM20

GE1XM25S

E1X 25S

25

11.1 - 19.9

14.0 - 22.0

GLSM25

GE1XM25

E1X 25

25

11.1 - 20.0

18.2 - 26.2

GLSM25

GE1XM32

E1X 32

32

17.0 - 26.3

23.7 - 33.9

GLSM32

GE1XM40

E1X 40

40

22.0 - 32.2

27.9 - 40.4

GLSM40

GE1XM50S

E1X 50S

50

29.5 - 38.2

35.2 - 46.7

GLSM50

GE1XM50

E1X 50

50

35.6 - 44.1

40.4 - 53.1

GLSM50

GE1XM63S

E1X 63S

63

40.1 - 50.0

45.6 - 59.4

GLSM63

GE1XM63

E1X 63

63

47.2 - 56.0

54.6 - 65.9

GLSM63

GE1XM75S

E1X 75S

75

52.8 - 62.0

59.0 - 72.1

GLSM75

GE1XM75

E1X 75

75

59.1 - 68.0

66.7 - 78.5

GLSM75

GE1XM90

E1X 90

90

66.6 - 80.0

76.2 - 90.4

GLSM90

GE1XM100

E1X 100

100

76.0 - 91.0

89.1 - 101.5

GLSM100

GE1XM115

E1X 115

115

86.0 - 98.0

101.3 - 110.3

GLSM115

GE1XM130

E1X 130

130

97.0 - 115.0

114.0 - 123.3

GLSM130

Nylon Cable Glands for unarmoured cablesFire Resistant (IEC N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, 60331)

IP68 rated glands which seal onto the outer sheath. Ideal for use on flexible cables and screened cables where the screen it terminated inside the enclosure. If the gland is not being used on a threaded enclosure you may require a locknut which is sold separately. -30°C to +80°C.

Nylon Gland

cables

FS

ISO Metric Thread Part No.

FS cables

cables

FS

Size

German PG Thread

Spanner Cable O/D Size Range (mm)

Locknut

Part No.

Size

Spanner Size

Cable O/D Range (mm)

Locknut

GLP07x

GNM12x

M12

15

3.0-6.5

GLNM12x

GNP07x

PG7

15

3.0-6.5

GNM16x

M16

19

5.0-10.0

GLNM16x

GNP09x

PG9

19

4.0-8.0

GLP09x

GNM20x

M20

24

6.0-12.0

GLNM20x

GNP11x

PG11

22

5.0-10.0

GLP11x

GNM25x

M25

33

9.0-17.0

GLNM25x

GNP13x

PG13

24

6.0-12.0

GLP13x

GNM32x

M32

42

18.0-25.0 GLNM32x

GNP16x

PG16

27

10.0-14.0

GLP16x

GNM40x

M40

53

22.0-32.0 GLNM40x

GNP21x

PG21

33

13.0-18.0

GLP21x

GNM50x

M50

60

30.0-38.0 GLNM50x

GNP29x

PG29

42

18.0-25.0

GLP29x

GNM63x

M63

68

34.0-42.0 GLNM63x

GNP36x

PG36

53

22.0-32.0

GLP36x

GNP42x

PG42

60

30.0-38.0

GLP42x

GNP48x

PG48

65

34.0-44.0

GLP48x

To show the colour required please replace x in the part number with:

FS cables

0

Black

3

Red

4

White

www.fscables.com

5

Grey - RAL 7001

6

Light Grey - RAL 7035

sales@fscables.com


147

Jointing Kits GLANDS Jointing Kits N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC 60331)

???

A range of jointing kits are provided to enable the safe connection of cables either above or below ground. Suitable for use on data, signal, telephone or power cables with or without armour, the conductors are first jointed using the appropriate connector then the outer shell is put in place and filled with a two part polyurethane resin. The resin is supplied in a fully enclosed easy-mixing sachet for a simple, clean application. These joints will last for years in either fixed or permanent installations. Please note the jointing boxes below include the shells, resin and armour bonds. They do not include the conductor joints which will vary depending on the type of cable and need to be ordered separately. Crimps are also available for telephone cables and solid conductor data cables.

Part No.

Cable O/D Range (mm)

Internal Length (mm)

Internal Width (mm)

Part No.

Cable O/D Range (mm)

Internal Length (mm)

Internal Width (mm)

JK1 JK2 JK3 JK4

12 - 26 14 - 32 23 - 39 28 - 50

185 245 325 375

35 48 52 68

JK5 JK6 JK7 JK8

32 - 58 45 - 75 40 - 89 57 - 95

520 705 862 900

102 124 140 150

Crimp Lugs Crimp Lugs N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant (IEC Crimp lug for jointing two power cable conductors. Crimps are sold singularly so you need to order the correct number to suit 60331) the cable you are jointing. Armour bonds are included for jointing SWA cables.

Conductor Size mm²

1.5 2.5 4.0 6.0

Lug Part No.

Conductor Size mm²

LUC015 LUC025 LUC040 LUC060

Lug Part No.

10 16 25 35

Conductor Size mm²

LUC100 LUC160 LUC250 LUC350

50 70 95 120

Description

Max. No. Wires

Length mm

Width mm

Open Height mm

Closed Height mm

8A/1 connector 8B connector 11A connector

2 3 2

14.85 16.25 12.60

9.75 12.65 12.50

9.00 9.00 9.30

6.40 6.40 5.80

Conductor Dia. Min. & Max. mm

FS

0.4 – 0.9 0.4 – 0.9 0.4 – 0.9 cables

FS

2.10 2.10 2.06cables

FS

FS

FS

cables

cables

Fax : 01727 840 842

Max. Dia. inc Insulation mm

FS

cables

Tel: 01727 840 841

FS

cables

cables

8A/1 8B 11A

LUC500 LUC700 LUC950 LUC120

FS

Connectors for Solid Telecom Conductors Part No.

Lug Part No.

cables


148

TOOLS

Tools High quality tools needn’t cost a fortune. Designed with the operator in mind and a long service life you can be confident the FSC range of tools will do the job. Covering crimping, cutting, stripping and installation, these tools have been chosen for their ease of use and cost effectiveness. Try a single piece and if you agree that they are great value for money, enjoy the quantity discounts offered on multiple items.

YTC1

Coax Connector Tools A range of well made and competitively priced tools to crimp most types of connectors from BNC to N-Type onto various coaxial cables. Part No.

YTS1

Description

Handle Colour

YTC1

Crimp Tool 1 for RG58, RG59, RG62, RG59 Mini & PSF 1/3

Yellow

YTC2

Crimp Tool 2 for RG59, CT100, CT125

Green

YTC3

Crimp Tool 3 for RG11, RG213 & CT125 (BNC only)

Blue

YTC10

Crimp Tool 10 for Firetuf Coax Cable 387FTC5903

Blue

Part No.

Description

YTS1

Cable Stripper for RG58 & RG59

YTS2

Cable Stripper for Cat 5E & Cat 6

RJ45 Tools YTC5

Designed to crimp RJ45 connectors up to 10 pin onto solid or stranded conductors. Suitable for most popular RJ45 connectors. Part No.

Description

YTC5

Handle Colour

Crimp tool 5 for RJ45 connectors

Orange

Cable Jacket Strippers cables

FS

YCS1

A safe and quick way of scoring and stripping sheaths and jackets from SWA, LSHF or PVC mains or control cables. Blades are adjustable for depth and direction. Metal cutting parts are used to reduce wear and replacement blades are available to ensure a long service life. Part No.

Description

YCS1

FS cables

Adjustable Cable Slitter for O/D 4.5mm to 25mm

YCS1-Spare

YRT1

Spare Blade for Adjustable Cable Slitter (YCS1)

BNC Removal Tools Allows easy installation and removal of terminated coaxial leads from panels where it can involve working in very tight spaces with large numbers of leads. Part No.

cables

FS

FS cables

Description

YRT1

Removal Tool for BNC connectors 12” long

YRT2

Removal Tool for F-Type connectors 12” long

www.fscables.com

sales@fscables.com


149

TOOLS Kevlar Scissors

YFOS

Designed to cut kevlar, polyaramid or strainer elements in fibre optic cables, these scissors are also ideal to neatly cut copper wire braids on coax or screened data and control cables. Part No.

Description

YFOS

Handle Colour

Scissors for cutting kevlar, polyaramid or braids

Black

Hand Cable Cutters

YCC162

A range of strong yet competitively priced cutters to meet most electricians’ needs. These large heavy duty cable cutters are widely used by wholesalers and cable distributors as well as contractors and installers. Cutting Range

Overall Length mm

YCC162

Part No.

Hand Cable Cutters

Description

Up to 6mm²

160

YCC235

Hand Cable Cutters

Up to 35mm²

235

Cable Cutters - Tubular Steel Handles

YCC350

Compact low cost cutters ideal for site or stockists. Suitable for flexible, data, telecoms and other unarmoured cables. Cutting Range Cu or Al

Overall Length mm

YCC350

Part No.

Hand Cable Cutters

Description

Up to 120mm²

350

YCC540

Hand Cable Cutters

Up to 240mm²

540

YCC700

Hand Cable Cutters

Up to 500mm²

700

Cable Cutters - Cast Aluminium Handles

YCC600

Lightweight yet tough, these cable cutters are ideal where large quantities of cuts are carried out. They are particularly suitable for cable distributors and railway, telecoms and strip-out contractors. Part No.

Overall Length mm

Hand Cable Cutters

Description

Up to 120mm²

320

YCC600

Hand Cable Cutters

Up to 240mm²

600

YCC810

Hand Cable Cutters

Up to 500mm²

810

cables

FS

Cable Cutters - Telescopic Handles

YCCT300

FS

Tough yet compact, these cutters with pull out and twist-to-lock telescopic handles are great for keeping in a tool box. The extending handles also give extra leverage when cutting large cables.

cables

Part No.

Description

FS

cables

Cutting Range Cu or Al

YCC320

Cutting Range Cu or Al

Overall Length mm

Up to 120mm²

300 – 400

Hand Cable Cutters

Up to 240mm²

415 - 565

cables

FS

FS

FS

FS

Cutting Range refers to the total cross-sectional area of the conductors i.e. 1 x 120mm2 or 4 x 25mm2. All dimensions are approximate.

cables

Hand Cable Cutters

YCCT415

cables

YCCT300

FS

Hand cutters should never be forced or have the handles extended to give extra leverage.

Tel: 01727 840 841

Fax : 01727 840 842

cables

cables


150

TOOLS Hydraulic Tools for Cutting Hydraulic cutters are an easy way of cutting large or medium sized copper or aluminium cables. They are particularly useful when working in confined spaces such as panels, transformers or trenches where there may not be sufficient room to use conventional cutters or where the physical force required to cut the cable is too great. Extensively used on site where cutting large armoured cables safely and with minimal effort is required.

YHC600

Hand Operated – Hydraulic Cutters These hydraulic cutters feature hardened blades to cut most types of telecom, power (including SWA) and large flexible cables. Competitively priced and complete with a steel case these cutters are ideal for use on site. Part No.

Description

Cutting range O/D mm

Cutting Force (Tonnes)

Length mm

YHC600

Hydraulic Cutters

40

12

600

YHC630

Hydraulic Cutters

45

12

630

*YHC600 is also suitable for cutting steel rope up to 28mm in diameter.

YHC560

Hand Operated – Hydraulic Cutters Features a flip-open cutter head for quick and easy cutting, and a rotatable head for cutting at any angle. The cutter has a two stage hydraulic action for faster cutting and either automatic or manual pressure release at the end or during the cut cycle. Part No.

YHH340

cables

FS

FS

Description

Cutting range O/D mm

Cutting Force

Length mm

YHC560

Hydraulic Cutters

45

60 KN

560

YHC680

Hydraulic Cutters

85

60 KN

680

Hydraulic Cutters Heads Cutting heads are ideal for either working in confined spaces or mounting on equipment or machinery. They can be powered either by hand or foot operated hydraulic pumps or a motorised version linked by a flexible hose. Part No.

Description

Cutting range O/D mm

Cutting Force (Tonnes)

Length mm

YHH340

Hydraulic Cutters

YHH515

Hydraulic Cutters

45

12

340

75

7.5

515

cables

cables

FS

*Please note, all cutters are designed to cut copper and aluminium conductors with most types of insulation or sheath. Some will also cut SWA (armoured cable) and steel tape armour but this will blunt the cutting surface more quickly. Hand cutters should never be forced or have the handles extended to give extra leverage. All dimensions are approximate and colours may vary.

FS cables

www.fscables.com

sales@fscables.com


151

TOOLS Hydraulic Power Pumps

YHP510

Designed to work with hydraulic cutting heads YHH340 & YHH515 the pump will also power crimpers, benders, rebar cutters and hole punches. Part No.

Description

Max. Output Pressure (Low)

Max. Output Pressure (High)

Size mm

YHP510

Hand Hydraulic Power Pumps

20kg/cm²

700kg/cm²

510 x 150 x 200

YHP450

Foot Hydraulic Power Pumps

20kg/cm²

700kg/cm²

450 x 150 x 200

Hand Operated - Hydraulic Tools for Crimping

YHT425

Cost effective crimpers that are easy to operate and ideal for site work. They are packed in a storage box complete with interchangable hexagon crimping dies to cover the crimping range. Fixed crimping head. Part No.

YHT425

Description

Hydraulic Crimp Tool

Crimping Range

Length mm

10 – 120mm²

425

Hand Operated - Hydraulic Tools for Crimping

YHT370

High quality crimpers ideal for rental and hire companies due to their long service life. They are packed in storage cases with a full set of hardened crimping dies to suit. Quick pressure release can be operated at any stage of operation. Rotatable head allows work in confined spaces and both models are suitable for inline crimps. YHT560 has a C shaped crimping head for open access. Part No.

Description

Crimping range

Crimping Force

Length mm

YHT370

Hydraulic Crimp Tool

10 – 150mm²

6

370

YHT560

Hydraulic Crimp Tool

16 – 400mm²

13

560

Compact light weight hole punch for use on panels, trunking and cabinets as well as other mild or stainless steel sheet. Rotatable head allows for comfortable working. Punching Range Part No.

YHP310

Mild Steel ≤ 3mm

Mild Steel ≤ 2mm

16.5 – 60.5

16.5 – 115.5

YHP310

FS

cables

cables

FS

Hand Operated Hydraulic Hole Punch

FS

FS

FS

FS

FS

FS

Stainless Steel ≤ 2mm

16.5 – 60.5 cables

cables

Standard round cutters included, square cutters are also available to order.

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables


152

SPECIAL MANUFACTURE N2XCH-FE180/E90: XLPE/Cu/LSHF Screened, Fire Resistant Custom-made Cables (IEC 60331) You specify, we supply – with quantities as low as 100 metres in some cases. The options outlined on these pages are the main variations and can be combined in any way to meet your particular specifications. Talk to us about cost-effective solutions for applications that are not mentioned here.

Composite and Special Cables There is an increasing need for cable to be manufactured to customers’ specific requirements. This can be as basic as a special colour code or jacket colour, right through to cables containing mixed core sizes (as well as a coax), with various levels of screening or armouring. At FSC we have considerable experience of ensuring that ‘specials’ meet your design criteria.

Outdoor and Duct Grade Sheaths In situations where the cable runs outside or through ducts polyethylene sheathing is the ideal solution. This material is tough, water-resistant and has natural low friction, making it easy to pull through ducts. It is also ideal for clipping to the outside of buildings offering good resistance to sunlight. cables

FS

FS cables

Two types of polyethylene are used, Low Density (LDPE) and High Density (HDPE). LDPE offers reasonable flexibility and mechanical protection. It is particularly suited to small data cables, while HDPE is much stiffer and is normally used for larger cables where no flexibility is required. Even quantities as low as 100m can be oversheathed, which allows you to use the same basic cable throughout an installation but with the added protection needed.

Special Colours Many cables can be supplied in a range of jacket colours.

cables

FS

FS cables

Existing cables can be coloured either by dyeing if they are PVC, or otherwise oversheathed to match an existing colour scheme or for identifying circuits, for example alarm data wiring. Talk to us about the options available.

www.fscables.com

sales@fscables.com


153

SPECIAL MANUFACTURE Braiding For added protection cables can be braided with a galvanised steel wire braid (GSWB) or heavy tinned copper wire. Braiding maintains a degree of flexibility, which may be important during installation or if the equipment needs to be moved for maintenance or is subject to vibration.

Armouring Armouring is best suited for fixed installations and particularly direct burial. Both types of protection are sheathed with either an exterior grade PVC or polyethylene. Low Smoke Halogen Free sheaths for special installations are also available. Standard cables can be braided or armoured for quantities as low as 100m.

Custom Made Leads & Assemblies For most jobs time is money and you cannot afford to make a mistake. To reduce installation time and cost many system manufactures are now operating a plug and play design allowing the installer to simply plug pre-manufactured leads into modules for right first time termination.

FS

FS

cables

FS

FS

FS

FS

FS

cables

FS

cables

To meet these growing demands we are able to supply many of the coax, data and instrumentation cables listed in the catalogue as pre-terminated leads to save you time and money. All we need to know is the length and the connector type you require - we will do the rest.

Printed Sheaths

cables

Cables can be printed with your company name, telephone number or an identification code such as a batch or location number.

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables


154

TECHNICAL Table 4F1A 60oC Thermosetting Insulated Flexible Cables With Sheath, Non-Armoured

Table 4F1A

CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area

1 (mm ) 4 6 10 16 2

25 35 50 70 95

Ambient temperature: 30ยบC Conductor operating temperature: 60ยบC

Single-phase a.c. or d.c.

Three-phase a.c.

Single-phase a.c. or d.c.

1 two-core cable, with or without protective conductor 2

1 three-core, four-core or five-core cable

2 single-core cable

3

4

(A) 30 39 51 73

(A) 26 34 47 63

(A) -

97 -

83 102 124 158 192

140 175 216 258

Refer to Notes 1, 2 & 3 below Notes: 1. The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. If the cable is to be wound on a drum on load the ratings should be reduced in accordance with Note 2 below and for cables which may be covered, Note 3 below. cables

FS

2. Flexible cables wound on reeling drums The current ratings of cables used on reeling drums are to be reduced by the following factors: a) Radial type drum ventilated: unventilated:

FS

b) Ventilated cylindrical type drum 85% 1 layer of cable: 85% 75% 2 layers of cable: 65% 3 layers of cable: 45% 4 layers of cable: 35%

cables A radial type drum is one where spiral layers of cable are accommodated between closely spaced flanges; if fitted with solid flanges the ratings given above should be reduced and the drum is described as non-ventilated. If the flanges have suitable apertures the drum is described as ventilated. A ventilated cylindrical cable drum is one where layers of cable are accommodated between widely spaced flanges and the drum and end flanges have suitable ventilating apertures.

FS

cables

3. Where cable may be covered over or coiled up whilst on load, or the air movement over the cable restricted, the current rating should be reduced. It is not possible to specify the amount of reduction but the table of rating factors for reeling drums can be used as a guide.

FS cables

www.fscables.com

sales@fscables.com


155

Table 4F1B TECHNICAL Table

4F1B

600C Thermosetting Insulated Flexible Cables

VOLTAGE DROP (per ampere per metre): Conductor Two-core crosscable, sectional d.c. area 1

Two-core cable, single-phase a.c.

2

(mm2) (mV/A/m) 4 6 10 16

12 7.8 4.6 2.9

Conductor operating temperature: 60ยบC

d.c.

Single-phase a.c.*

3

4

5

6

(mV/A/m)

(mV/A/m)

(mV/A/m)

(mV/A/m)

12 7.8 4.6 2.9 r

2 single-core cables, touching

1 three-core, four-core or five-core cable, three-phase a.c.

x

10 6.7 4.0 2.5 z

0.175 1.85

r

-

x

-

z

r

x -

z

25

1.80

1.80

1.55

0.150

1.55

-

-

35

-

-

-

-

1.10

0.150

1.15

1.31

1.31

0.21

1.32

-

50

-

-

-

-

0.83

0.145

0.84

0.91

0.91

0.21

0.93

70

-

-

-

-

0.57

0.140

0.58

0.64

0.64

0.20

0.67

95

-

-

-

-

0.42

0.135

0.44

0.49

0.49

0.195

0.53

Notes: * A larger voltage drop will result if the cables are spaced.

These extracts from the 17th Edition Wiring Regulations

FS

FS

FS

cables

FS

FS

FS

FS

FS

cables

Engineering and Technology and British Standards

cables

are reproduced by kind permission of the Institution of Institution. Copyright IET / BSI 2008. The extracts are for guidance only, please refer to

cables

BS 7671: 2008 Requirements for Electrical Installations (IEE Wiring Regulations 17th Edition) for further reference.

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables


156

TECHNICAL Table 4D2A & 4D2B Multicore 70oC Thermoplastic Insulated and Thermoplastic Sheathed Cables, Non-Armoured

Table 4D2A

CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area

Reference Method A (enclosed in conduit in thermally insulating wall etc.)

Reference Method B (enclosed in conduit on a wall or in trunking etc.)

1 two1 three1 twocore cable* core cable* core singleor cable* phase 1 four-core singlea.c. or d.c. cable, three- phase phase a.c. a.c. or d.c.

1

Ambient temperature: 30ยบC Conductor operating temperature: 70ยบC Reference Method C (clipped direct)

Reference Method E (free air or on a perforated cable tray etc, horizontal or vertical)

1 three1 two 1 three1 two1 threecore core cable* core cable* core cable* core cable* cable* singleor singleor or phase 1 four-core phase 1 four-core 1 four-core a.c.or d.c. cable, a.c. or d.c. cable, cable, threethreethree phase a.c. phase a.c. phase a.c.

2

3

4

5

6

7

8

9

(mm2)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

1 1.5 2.5 4 6 10 16

11 14 18.5 25 32 43 57

10 13 17.5 23 29 39 52

13 16.5 23 30 38 52 69

11.5 15 20 27 34 46 62

15 19.5 27 36 46 63 85

13.5 17.5 24 32 41 57 76

17 22 30 40 51 70 94

14.5 18.5 25 34 43 60 80

* With or without protective conductor.

Table 4D2B cables

FSConductor cross-

sectional area 1

FS

(mm ) 1 cables 1.5 2.5 4 6 10 16 cables

FS

FS cables

2

VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 70ยบC Two-core cable d.c.

Two-core cable single-phase a.c.

2

3

4

(mV/A/m) 44 29 18 11 7.3 4.4 2.8

(mV/A/m) 44 29 18 11 7.3 4.4 2.8

(mV/A/m) 38 25 15 9.5 6.4 3.8 2.4

www.fscables.com

Three- or four-core cable three-phase a.c.

sales@fscables.com


157

Table 4E2A & 4E2B TECHNICAL

Multicore 90oC Thermosetting Insulated and Thermoplastic Sheathed Cables, Non-Armoured

Table 4E2A

CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area

Reference Method B (enclosed in conduit on a wall or in trunking etc.)

Reference Method A (enclosed in conduit in thermally insulating wall etc.) 1 two1 threecore cable* or four-core singlecable*, phase threea.c. or d.c. phase a.c.

1

2

(mm2) 1 1.5 2.5 4 6 10 16

(A) 14.5 18.5 25 33 42 57 76

Ambient temperature: 30ºC Conductor operating temperature: 90ºC Reference Method E (free air or on a perforated cable tray etc, horizontal or vertical)

Reference Method C (clipped direct)

1 two-core cable*, singlephase a.c. or d.c.

1 threeor four-core cable*, threephase a.c.

1 two-core cable* singlephase a.c.or d.c.

1 threeor four-core cable*, threephase a.c.

1 two-core cable*, singlephase a.c. or d.c.

4

5

6

7

8

9

(A) 15 19.5 26 35 44 60 80

(A) 19 24 33 45 58 80 107

(A) 17 22 30 40 52 71 96

(A) 21 26 36 49 63 86 115

(A) 18 23 32 42 54 75 100

3 (A) 13 16.5 22 30 38 51 68

(A) 17 22 30 40 51 69 91

1 threeor four-core cable*, threephase a.c.

Notes: 1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature (see Regulation 512.1.2) 2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC, the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables (Table 4D2A) must be used (see also Regulation 523.1) * With or without protective conductor.

Table 4E2B VOLTAGE DROP (per ampere per metre): Conductor operating temperature: 90ºC

3

(mV/A/m) 46 31 19 12 7.9 4.7 2.9

(mV/A/m) 46 31 19 12 7.9 4.7 2.9

Tel: 01727 840 841

Fax : 01727 840 842

FS

FS

cables

FS

FS

FS

FS

FS

4

(mV/A/m) 40 27 16 10 6.8 4.0 2.5

cables

cables

cables

2

FS

Three-or four-core cable, three-phase a.c.

cables

Two-core cable single-phase, a.c.

cables

(mm2) 1 1.5 2.5 4 6 10 16

Two-core cable, d.c.

cables

Conductor crosssectional area 1

cables


cables

FS

FS

cables

cables

FS

FS

cables

www.fscables.com

2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ยบC, the current ratings given in the equivalent table for 70ยบC thermoplastic insulated cables (Table 4D1A) must be used (see also Regulation 523.1)

1. Where a conductor operates at a temperature exceeding 70ยบC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature (see Regulation 512.1.2)

Notes:

26

35

45

61

81

106

131

158

200

241

6

10

16

25

35

50

70

95

1.5

4

14

19

1

2.5

2

(A)

1

2 cables, singlephase a.c. or d.c.

sales@fscables.com 216

179

141

117

95

73

54

40

31

23

17

13

(A)

3

3 or 4 cables, threephase a.c.

Reference Method A (enclosed in conduit in thermally insulating wall etc.)

(mm2)

Conductor crosssectional area

306

253

198

164

133

100

75

54

42

31

23

17

(A)

4

2 cables, singlephase a.c. or d.c.

269

222

175

144

117

88

66

48

37

28

20

15

(A)

5

3 or 4 cables, threephase a.c.

Reference Method B (enclosed in conduit on a wall or in trunking etc.)

355

293

228

176

143

109

81

59

46

34

25

19

(A)

6

2 cables, singlephase a.c. or d.c. flat and touching

326

268

209

161

130

99

74

54

41

31

23

17.5

(A)

7

3 or 4 cables threephase a. c. flat and touching or trefoil

Reference Method C (clipped direct)

CURRENT-CARRYING CAPACITY (amperes):

377

310

242

200

161

-

-

-

-

-

-

-

(A)

8

342

279

216

176

141

-

-

-

-

-

-

-

(A)

9

2 cables, 3 singlecables, phase a.c. three-phase or d.c. flat a.c.flat

328

268

207

169

135

-

-

-

-

-

-

-

(A)

10

3 cables, threephase a.c. trefoil

Reference Method F (in free air on a perforated cable tray horizontal or vertical etc.) Touching

430

353

275

226

182

-

-

-

-

-

-

-

(A)

11

Horizontal

389

318

246

201

161

-

-

-

-

-

-

-

(A)

12

Vertical

2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat

Spaced by one cable diameter

Reference Method G (in free air)

Ambient temperature: 30ยบC Conductor operating temparature:90ยบC

Table

Single Core 90oC Thermosetting Insulated Cables, Unarmoured, With or Without Sheath

158 TECHNICAL Table 4E1A

4E1A


0.68 0.26 0.73

0.68 0.175 0.71

0.70 0.28 0.75

0.68

70

0.51 0.27 0.58

cables

FS

cables

FS

cables

FS 0.49 0.170 0.52

0.49 0.26 0.56

Notes: *Spacings larger than one cable diameter will result in a larger voltage drop.

0.49

0.99 0.27 1.00

0.99 0.180 1.00

1.00 0.29 1.05

0.99

50

FS cables

Fax : 01727 840 842

95

1.35 0.27 1.35

1.35 0.180 1.35

1.35 0.29 1.35

1.35

x

z

35

r 1.85 0.28 1.85

x

z

1.85 0.190 1.85

r

1.85 0.31 1.90

z

1.85

x

(mV/A/m) 46 31 19 12 7.9 4.7 2.9

25

r

(mV/A/m) 46 31 19 12 7.9 4.7 2.9

(mV/A/m) 46 31 19 12 7.9 4.7 2.9

(mV) 46 31 19 12 7.9 4.7 2.9

5

Cables spaced*

(mm2) 1 1.5 2.5 4 6 10 16

4

3

Cables touching

Reference Methods C, F & G (clipped direct, on tray or in free air)

2

cables

Tel: 01727 840 841

FS

cables

1

Reference Methods A & B (enclosed in conduit or trunking)

2 cables, single-phase a.c.

VOLTAGE DROP (per ampere per metre):

2 cables d.c.

x

z

0.44 0.23 0.50

0.60 0.24 0.65

0.87 0.25 0.90

1.15 0.25 1.15

1.60 0.27 1.65

r

(mV/A/m) 40 27 16 10 6.8 4.0 2.5

Reference Methods A & B Reference (enclosed in conduit or trunking) 6

Conductor operating temperature: 90ยบC

x

z

0.43 0.145 0.45

0.59 0.150 0.61

0.86 0.155 0.87

1.15 0.155 1.15

1.60 0.165 1.60

r

(mV/A/m) 40 27 16 10 6.8 4.0 2.5

Cables touching, Trefoil 7

x

z

0.43 0.170 0.46

0.59 0.175 0.62

0.86 0.180 0.87

1.15 0.180 1.15

1.60 0.190 1.60

r

(mV/A/m) 40 27 16 10 6.8 4.0 2.5

Cables touching, Flat 8

x

z

0.43 0.25 0.49

0.59 0.25 0.65

0.86 0.26 0.89

1.15 0.26 1.20

1.60 0.27 1.65

r

(mV/A/m) 40 27 16 10 6.8 4.0 2.5

Cables spaced*, Flat 9

Reference Methods C, F & G (clipped direct, on tray or in free air)

3 or 4 cables, three-phase a.c.

Table

Conductor crosssectional area

Single Core 90oC PVC Thermosetting Insulated Cables

Table 4E1B TECHNICAL

159

4E1B

FS

FS

cables

FS

cables


160

TECHNICAL Table 4F2A

4F2A

Table

90oC and 180oC Thermosetting Insulated Flexible Cables With Sheath, Non-Armoured Ambient temperature: 30ºC Conductor operating temperature: 90ºC

CURRENT-CARRYING CAPACITY (amperes): Conductor crosssectional area

d.c. or single-phase a.c. (1 two-core cable, with or without protective conductor)

Three-phase a.c. (1 three-core, four-core or five-core cable)

Single-phase a.c. or d.c., 2 single-core cables, touching

1

2

3

4

(A) 42 55 76 103 136 -

(A) 37 49 66 89 119 146 177 225 273

(A) 200 250 310 369

(mm ) 4 6 10 16 25 35 50 70 95 2

Refer to Notes 1 to 3 on page 154 and Notes 4 to 6 below

RATING FACTOR FOR AMBIENT TEMPERATURE: 90ºC thermosetting insulated cables: cables

FS

Ambient temperature

35ºC 40ºC

45ºC

50ºC

55ºC

60ºC

65ºC

70ºC

75ºC

80ºC

85ºC

Rating factor

0.95 0.91

0.86

0.82

0.76

0.70

0.64

0.57

0.50

0.40

0.28

180ºC thermosetting insulated cables:

FS

Ambient temperature 35ºC to 90ºC cables Rating factor 1.0

95ºC 100ºC 105ºC 110ºC 0.96

0.91

0.86

0.81

115ºC 120ºC 125ºC 130ºC 135ºC 140ºC 145ºC 0.76

0.70

0.64

0.57

0.50

0.40

0.28

Notes: 4. For 180ºC cables the rating factors for ambient temperature allow a conductor operating temperature up to 150ºC. Consult the cable manufacturer for further information. cables

FS

5. The temperature limits given in the 17th Edition Wiring Regulations hould be taken into account when it is intended to operate these cables at maximium permissible temperature.

6. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temeperature (see Regulation 512.1.2)

FS cables

www.fscables.com

sales@fscables.com


161

Table 4F2B TECHNICAL Table

4F2B

90oC and 180oC Thermosetting Insulated Flexible Cables

VOLTAGE DROP (per ampere per metre): Conductor crosssectional area

1 two-core or 2 singlecore cables d.c.

1 (mm2) 4 6 10 16 25 35

2.03 1.42

50 70 95

1.00 0.71 0.54

1 three-core, four-core or five-core cable, three-phase a.c.

Two-core cable, single-phase a.c.

2 single-core cables, touching Single-phase a.c.*

2 (mV/A/m) 13.2 8.5 5.1 3.2

Conductor operating temperature: 90ยบC

3 (mV/A/m) 13.2 8.5 5.1 3.2 r x 2.03 0.175 -

-

4

z 2.04 -

5

(mV/A/m) 11.1 7.4 4.4 2.7 r x 1.73 0.15 1.22 0.15

z 1.73 1.23

0.91 0.62 0.47

0.93 0.64 0.49

0.145 0.14 0.135

r 1.44

(mV/A/m) x 0.21

z 1.46

1.00 0.71 0.54

0.21 0.20 0.195

1.02 0.73 0.57

Notes: 1. The voltage drop figures given above are based on a conductor operating temperature of 90ยบC and are therefore not accurate when the operating temperature is in excess of 90ยบC. In the case of the 180ยบC cables with a conductor temperature of 150ยบC the above resistive values should be increased by a factor of 1.2. 2 * A larger voltage drop will result if the cables are spaced.

FS

cables

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

FS

cables

FS

cables


162

TECHNICAL Table 4F3A

4F3A

Table

Flexible Cords, Non-Armoured

CURRENT-CARRYING CAPACITY (amperes): and MASS SUPPORTABLE (kg): Current-carrying capacity

Conductor cross-sectional area

Single-phase a.c.

Three-phase a.c.

1

Maximum mass supportable by twin flexible cord (see Regulations 522.7.2 and 559.6.1.5)

2

3

4

2

(mm )

(A)

(A)

(kg)

0.5 0.75 1 1.25 1.5 2.5 4

3 6 10 13 16 25 32

3 6 10 16 20 25

2 3 5 5 5 5 5

Where cable is on a reel see the notes to the Table in 4F1A RATING FACTOR FOR AMBIENT TEMPERATURE 60ºC Thermoplastic or Thermosetting Insulated Cords: 35ºC 40ºC 45ºC 50ºC Ambient temperature Correction factor 0.91 0.82 0.71 0.58

55ºC 0.41

90ºC Thermoplastic or Thermosetting Insulated Cords: Ambient temperature 35ºC to 50ºC 55ºC 60ºC 65ºC Correction factor 1.0 0.96 0.83 0.67

70ºC 0.47

Ambient temperature Correction factor

cables

FS180ºC Thermosetting Insulated Cords:

FS

Glass Fibre Cords: Ambient temperature cables Correction factor

35ºC to 120ºC 1.0

125ºC 0.96

130ºC 0.85

135ºC 0.74

140ºC 0.60

145ºC 0.42

35ºC to 150ºC 1.0

155ºC 0.92

160ºC 0.82

165ºC 0.71

170ºC 0.57

175ºC 0.40

cables

FS

FS cables

www.fscables.com

sales@fscables.com


163

Table 4F3B TECHNICAL Table

4F3B

Flexible Cords Current Carrying Capacity / Voltage Drop

VOLTAGE DROP (per ampere per metre):

Conductor operating temperature: 60ยบC*

Conductor cross-sectional area

d.c. or single-phase a.c.

1

2

Three-phase a.c. 3

(mm2) 0.5 0.75 1 1.25 1.5 2.5 4

(mV/A/m) 93 62 46 37 32 19 12

(mV/A/m) 80 54 40 27 16 10

Notes: *The tabulated values above are for 60ยบC thermoplastic or thermosetting insulated flexible cords and for other types of flexible cords they are to be multiplied by the following factors: For 90ยบC Thermoplastic or Thermosetting Insulated

1.09

180ยบC Thermosetting Insulated

1.31

185ยบC Glass Fibre

1.43

FS

cables

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

FS

cables

FS

cables


164

TECHNICAL AWG/Metric Conversion

American Wire Gauge to Metric Conversion - Listed below are some of the most popular strandings, however, many other combinations exist. Resistance figures are approximate and are given for guidance only.

cables

FS

FS cables

cables

FS

FS cables

AWG

Cross Section mm2

Stranding

Resistance Ohm/km

AWG Cross Section Stranding mm2

38

0.008

1 x 0.10

2125

18

0.90

7 x 0.40

38

0.009

7 x 0.04

1930

18

0.96

19 x 0.25

17.9

36

0.013

1 x 0.12

1360

16

1.30

1 x 1.29

13.2

36

0.014

7 x 0.05

1217

16

1.23

19 x 0.28

14.0

34

0.020

1 x 0.16

856

14

2.08

1 x 1.62

8.28

34

0.022

7 x 0.06

777

14

1.94

19 x 0.36

8.86

32

0.032

1 x 0.20

538

12

3.31

1 x 2.05

5.20

32

0.034

7 x 0.08

538

12

3.08

19 x 0.45

5.58

32

0.035

19 x 0.05

446

10

5.26

1 x 2.58

3.28

30

0.051

1 x 0.25

338

10

5.26

19 x 0.6

3.28

30

0.057

7 x 0.10

338

8

8.38

1 x 3.26

2.06

30

0.059

19 x 0.06

286

8

8.35

19 x 0.75

2.06

28

0.080

1 x 0.32

213

6

13.29

1 x 4.11

1.59

28

0.089

7 x 0.12

213

6

13.29

19 x 0.96

1.59

28

0.090

19 x 0.08

186

4

21.15

1 x 5.18

0.815

26

0.128

1 x 0.40

134

4

21.14

19 x 1.19

0.815

26

0.141

7 x 0.16

122

2

33.63

1 x 6.54

0.513

26

0.155

19 x 0.10

113

2

33.61

19 x 1.50

0.513

24

0.205

1 x 0.51

84

1

42.41

1 x 7.34

0.424

24

0.227

7 x 0.20

76

1

42.38

19 x 1.68

0.424

24

0.241

19 x 0.12

69

1/0

53.4

19 x 1.89

0.253

22

0.324

1 x 0.64

53

2/0

67.4

19 x 2.17

0.291

22

0.355

7 x 0.25

48

4/0

107

19 x 2.68

0.182

22

0.382

19 x 0.16

45

250 MCM

127

37 x 2.09

0.139

20

0.519

1 x 0.81

33

300 MCM

152

37 x 2.29

0.119

20

0.563

7 x 0.32

30.4

350 MCM

177

37 x 2.47

0.102

20

0.616

19 x 0.20

28.3

400 MCM

202

37 x 2.64

0.091

18

0.785

16 x 0.25

21.2

500 MCM

253

37 x 2.95

0.072

18

0.823

1 x 1.02

20.9

www.fscables.com

Resistance Ohm/km 19.2

sales@fscables.com


165

Stranding Chart TECHNICAL Cross Section mm2

Nearest AWG Size*

Stranding Class 1

Stranding Class 2

Resistance Ohm/km Classes 1 & 2

Stranding Class 5

Stranding Class 6

Resistance Ohm/km Classes 5 & 6

Approx Weight kg/km

IEC 60228/BS 6360 Conductors for insulated cables 0.14

26

-

-

-

-

18 x 0.10

138

1.35

0.25

24

-

-

-

14 x 0.16

32 x 0.10

79

2.4

0.34

22

-

-

-

19 x 0.16

42 x 0.10

57

3.3

0.50

20

1 x 0.80

7 x 0.30

36.0

16 x 0.21

28 x 0.16

38

4.8

0.75

18

1 x 0.97

7 x 0.37

24.5

24 x 0.21

42 x 0.16

26

7.2

1.0

18

1 x 1.13

7 x 0.43

18.1

32 x 0.21

56 x 0.16

19.5

9.6

1.5

16

1 x 1.38

7 x 0.53

12.1

30 x 0.26

84 x 0.16

13.3

14.4

2.5

14

1 x 1.78

7 x 0.67

7.41

50 x 0.26

140 x 0.16

7.98

24

4.0

12

1 x 2.26

7 x 0.85

4.61

56 x 0.31

224 x 0.16

4.95

38

6.0

10

1 x 2.76

7 x 1.04

3.08

84 x 0.31

192 x 0.21

3.3

58

10

8

1 x 3.57

7 x 1.35

1.83

80 x 0.41

320 x 0.21

1.91

96

16

6

1 x 4.5

17 x 1.70

1.15

128 x 0.41

512 x 0.21

1.21

154

25

4

7 x 2.14

0.72

200 x 0.41

800 x 0.21

0.78

240

35

2

7 x 2.52

0.52

280 x 0.41

1120 x 0.21

0.55

336

50

1/0

19 x 1.78

0.39

400 x 0.41

705 x 0.31

0.39

480

70

2/0

19 x 2.14

0.27

356 x 0.51

990 x 0.31

0.27

672

95

3/0

19 x 2.52

0.19

485 x 0.51

1340 x 0.31

0.21

912

120

250MCM

37 x 2.03

0.15

614 x 0.51

1690 x 0.31

0.16

1152

150

300MCM

37 x 2.25

0.12

765 x 0.51

2123 x 0.31

0.13

1440

185

400MCM

37 x 2.52

0.1

944 x 0.51

1470 x 0.41

0.11

1776

240

500MCM

61 x 2.25

0.07

1225 x 0.51

1905 x 0.41

0.08

2304

300

600MCM

61 x 2.52

0.06

1530 x 0.51

2385 x 0.41

0.064

2880

400

750MCM

61 x 2.85

0.05

2035 x 0.51

0.068

3840

500

1000MCM

61 x 3.20

0.04

1768 x 0.60

0.0384

4800

FS

FS

cables

FS

FS

FS

FS

FS

cables

cables

FS

The number of strands according to IEC 60228/BS 6360 shown in classes 1 & 2 is obligatory. Stranding shown in classes 5 & 6 gives the maximum strand diameters and may have less strands provided the conductor does not exceed the resistance figures shown. In either case the standard gives the maximum resistance in ohms/km that is permissable for non-tinned conductors. * AWG sizes are approximate and for information only. Please contact us for exact sizing.

Fax : 01727 840 842

cables

cables

cables

Tel: 01727 840 841

cables

cables


166

TECHNICAL Colour Codes - American Style Colour Chart 1: Conductor/Colour

1 2 3 4

Black White Red Green

5 6 7 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red

1 2 3 4 5 6 7 8 9 10 11 12 13

Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White Red/Green Red/Blue Red/Yellow Red/Brown Red/Orange

Brown Blue Orange Yellow

9 10 11

Purple Grey Pink

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

White/Red/Orange Orange/White/Blue White/Red/Blue Black/White/Green White/Black/Green Red/White/Green Green/White/Blue Orange/Red/Green Blue/Red/Green Black/White/Blue White/Black/Blue Red/White/Blue Green/Orange/Red Orange/Red/Blue Blue/Orange/Red Black/Orange/Red

27 28 29 30 31 32 33 34 35 36 37

Brown/Orange Orange/Yellow Purple/Orange Purple/Red Purple/White Purple/Dark Green Purple/Light Blue Purple/Yellow Purple/Brown Purple/Black Grey/White

Colour Chart 2: Conductor/Colour 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34

Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White Orange Black/White/Orange

Colour Chart 3: Pair/Number Colour Combination

cables

FS

1 2 3 4 5 cables 6 7 8 9 10 11 12 13 14 15

FS cables

FS

FS cables

14 15 16 17 18 19 20 21 22 23 24 25 26

Green/White Green/Blue Green/Yellow Green/Brown Green/Orange White/Blue White/Yellow White/Brown White/Orange Blue/Yellow Blue/Brown Blue/Orange Brown/Yellow

Colour Chart 5: Western Electric Standard & CW1308 Telephone Cable Colour Chart

White/Blue White/Orange White/Green White/Brown White/Grey Red/Blue Red/Orange Red/Green Red/Brown Red/Grey Black/Blue Black/Orange Black/Green Black/Brown Black/Grey

Pair number/colour combination. The second colour denotes the band or stripe, however due to environmental issues the cores may be solid colours instead of bi-colours. Blue/White 16 Yellow/Blue Blue/Yellow Orange/White 17 Yellow/Orange Orange/Yellow Green/White 18 Yellow/Green Green/Yellow Brown/White 19 Yellow/Brown Brown/Yellow Grey/White 20 Yellow/Grey Grey/Yellow Blue/Red 21 Purple/Blue Blue/Purple Orange/Red 22 Purple/Orange Orange/Purple Green/Red 23 Purple/Green Green/Purple Brown/Red 24 Purple/Brown Brown/Purple Grey/Red 25 Purple/Grey Grey/Purple Blue/Black 26 Pink/Blue Blue/Pink Orange/Black 27 Pink/Orange Orange/Pink Green/Black 28 Pink/Green Green/Pink Brown/Black 29 Pink/Brown Brown/Pink Grey/Black 30 Pink/Grey Grey/Pink

www.fscables.com

sales@fscables.com


167

Colour Codes - European / UK TECHNICAL CW1600 Colour Codes Pairs

Colour of Insulation A-Wire B-Wire

1 2 3 4 5 6 7 8 9

White/Blue White/Orange White/Green White/Brown White/Grey Red/Blue Red/Orange Red/Green Red/Brown

Pairs

Blue Orange Green Brown Grey Blue Orange Green Brown

Colour of Insulation A-Wire B-Wire

9 10 11 12 13 14 15 16 17

Red/Brown Red/Grey Black/Blue Black/ Orange Black/Green Black/Brown Black/Grey Yellow/Blue Yellow/Orange

Pairs

Brown Grey Blue Orange Green Brown Grey Blue Orange

17 18 19 20 21 22 23 24 25

Colour of Insulation A-Wire B-Wire

Yellow/Orange Yellow/Green Yellow/Brown Yellow/Grey Violet/Blue Violet/Orange Violet/Green Violet/Brown Violet/Grey

Orange Green Brown Grey Blue Orange Green Brown Grey

On cables with over 25 pairs the first 20 pairs will be repeated with coloured separators or binder tapes to indicate each bundle.

Def Style Miniature Cables

CW1128 & CW1128/1198 Colour Coding Pair

A-Wire

B-Wire

1 2 3 4 5 6 7 8 9

White White White White White Red Red Red Red

Blue Orange Green Brown Grey Blue Orange Green Brown

10

Red

Grey

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Colours of tape lappings

1 2 3 4 5

Blue Orange Green Brown Grey

6 7 8 9 10

White Red Black Yellow Violet

Red Blue Green Yellow White Black Brown Violet Orange Pink Turquoise Grey Red/Blue Green/Red Yellow/Red White/Red Red/Black Red/Brown

19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Yellow/Blue White/Blue Blue/Black Orange/Blue Green/Blue* Grey/Blue* Yellow/Green White/Green* Green/Black Orange/Green* Grey/Green Yellow/Brown White/Brown Brown/Black Grey/Brown Yellow/Violet Violet/Black White/Violet

* Note: The colour code of 25 core cables has core colours 23 & 24 replaced with colours 26 & 28. For colour codes above 36 cores please ask for details.

HD 308 S2 BS 7671 Amendment 2: 2004 Colour Code New European Harmonised Standard For Mains Cables

FS

cables

FS

cables

Other colour codes for external telephone cables also exist.

The new colour code for mains cables is obligatory from April 2006 and applies to flexible and fixed cables connected to the mains. It does not apply to control or signal. Two Core Three Core Four Core Five Core Blue Green/Yellow Green/Yellow Green/Yellow Brown Brown Blue cables cables Blue Black Brown Brown Grey Black Cables without earth core: Grey or Green /Yellow Brown Blue Cables without earth core: Black Brown Blue Grey Black Brown Black Cables without earth core: Grey Blue Black DIN 47100 European Colour Codes Brown

FS

FS

Black Grey

See page 80

Tel: 01727 840 841

Fax : 01727 840 842

FS

FS

cables

cables

FS

cables

FS

cables


168

TECHNICAL Colour Codes - BS 5308

BS 5308 Part 1 Colour Code

BS 5308 Part 2 Colour Code

Unscreened & Collective Screened

Unscreened & Collective Screened

Pair No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 cables 46 47 48 49 50 cables

FS

FS FS

A - Wire

B - Wire

Black Black Blue Black Blue Green Black Blue Green Brown Black Blue Green Brown White Black Blue Green Brown White Red Black Blue Green Brown White Red Orange Black Blue Green Brown White Red Orange Yellow Black Blue Green Brown White Red Orange Yellow Grey Black Blue Green Brown White

Blue Green Green Brown Brown Brown White White White White Red Red Red Red Red Orange Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Yellow Yellow Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Violet Violet Violet Violet Violet Violet Violet Turquoise Turquoise Turquoise Turquoise Turquoise

cables

Single Quad (2 pair): Black, Blue, Green, Brown Single Triple: Blue, Black, Green Individually screened pairs can also be identified by a polyester tape over black and blue pairs

FS cables

Pair No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

A - Wire

B - Wire

White White White White White Red Red Red Red Red Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow White-Blue White-Blue White-Blue White-Blue White-Blue Red-Blue Red-Blue Red-Blue Red-Blue Red-Blue Blue-Black Blue-Black Blue-Black Blue-Black Blue-Black Yellow-Blue Yellow-Blue Yellow-Blue Yellow-Blue Yellow-Blue White Orange White Orange White Orange White Orange White Orange Orange-Red Orange-Red Orange-Red Orange-Red Orange-Red

Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey

Single Quad (2 pair): Blue, Green, Orange, Brown Single Triple: Blue, White, Orange Individually screened pairs can also be identified by a polyester tape over white and blue pairs

www.fscables.com

sales@fscables.com


169

LSHF Buyers Guide TECHNICAL Low Smoke Halogen Free Cabling When specifying cable for installations in confined areas, computer rooms and other sensitive environments, Low Smoke Halogen Free cables offer significant advantages over traditional PVC. Hospitals, airports and train stations are just some examples of areas that can be difficult to evacuate in the event of fire. It is now recognised that smoke and poisonous fumes can pose a far greater threat to life and property than the fire itself. Standard PVC cables are made up of halogens which, when burnt, give off toxic gases such as Hydrogen Chloride. When exposed to water – moisture in the air or fire sprinkler systems for example, hydrogen chloride forms highly noxious and corrosive hydrochloric acid.

3m³ smoke test to IEC 61034

The effects of burning PVC are two-fold. Firstly, the dense smoke produced can reduce visibility and obscure exit routes. Secondly the harmful hydrogen chloride gas given off is dangerous to people and also has a corrosive effect on electronic equipment potentially causing random, unpredictable failure over a period of time. Specifying Low Smoke Halogen Free (LSHF) cable goes a long way to reducing this risk. LSHF cables are those which emit negligible amounts of halogens when burnt and have reduced smoke emission properties. Compared with around 28% acid gas emissions of standard PVC, LSHF cables give off less than 0.5% HCl (Gases Evolved During Combustion BS EN 50267, IEC 60754-2). Visibility through smoke emission is measured through a 3m³ smoke test (pictured) to IEC 61034. Confusion still surrounds the terminology used to describe LSHF cables and caution should be exercised when specifying. While LSHF, LS0H, LSZH and 0HLS are the same, it is important to note that LSF is not. LSF (Low Smoke and Fume) often refers to modified PVC compound which can still emit up to 22% HCl and should be regarded as only slightly better than PVC in the event of fire. Also beware standard PVC cables which are over-sheathed with a LSHF compound. When the jacket burns through the PVC inner sheath or insulation will give off poisonous fumes in just the same way. The FSC range of LSHF cables are LSHF throughout – insulation and sheath.

FS

cables

FS

FS

FS

FS

FS

Fax : 01727 840 842

cables

cables

cables

cables

Tel: 01727 840 841

cables

FS

cables

FS

If you are unsure of what you are buying, ask for written confirmation that the cable is LSHF throughout.

cables


170

TECHNICAL Certificates & Trade Associations

ISO 9001 Accredited ISO 9001 is the internationally recognised standard for the quality management of businesses. Quality of service and products has been critical to our operation ever since we began. FS Cables has been a registered company with Quality Certification since 1996.

ISO 14001 Accredited ISO 14001 provides a framework for reducing our environmental footprint through a range of measurable improvement actions. At FS Cables we believe this accreditation demonstrates our commitment to environmental responsibility and sustainability. We have introduced a number of measures ranging from setting up a recycling up a recycling programme programme for for all office all office andand commercial commercial waste waste to car to sharing car sharing andand staffstaff cycling cycling or walking or walking to work. to work.

cables

FS

FS cables

ISO 14001inAccredited Investors People The 14001 ISO Investors provides in People a framework (IIP) Standard for reducing is a business our improvement environmentaltool footprint through designed to advance a range an organisation’s of measurable performance improvement through actions. its employees. At FS Cables we believe this accreditation demonstrates our commitment Awarded in 2005, to environmental the IIP Standard responsibility places strong and emphasis sustainability. on the personal development of our staff through regular review, evaluation We have introduced a number of measures ranging from setting up and assessment. a recycling programme for all office and commercial waste to car sharing By establishing and staff a culture cycling of or continuous walking to work. improvement through training we can ensure that you receive the best possible service.

cables

FS

FS cables

www.fscables.com

sales@fscables.com


171

Certificates & Trade Associations TECHNICAL

Link-up Registered

Caplink Ltd T/A Flexible & Specialist Cables Supplier Number: 22288

Date Printed: Expiry Date: Certificate Number:

31 March 2010 28 March 2011 4282-22288/70006

Peter Brookes Rail Sector Manager Achilles Information Limited

Link-up is the UK Rail industry supplier qualification and verification scheme, designed to assure the quality of products and services bought by the rail industry. It is administered on behalf of the rail industry by the Achilles Link-up Team and is supported and used by most of the major rail companies throughout the UK.

BSI Subscribing Member Subscribing membership to the BSI (British Standards Institute) ensures FS Cables can stay up to date with the latest standards and certification programmes. This enables us to adopt best practices in terms of our operations ensuring the products and services we offer our customers are to the highest standards.

KNX Manufacturer Member The KNX standard is an internationally recognised system for home automation and building control.

FS

FS

cables

FS

cables

FS

FS Cables is a manufacturer member of both the KNX worldwide and KNX UK Associations.

CEDIA Trade Supplier The Custom Electronic Design & Installation Association (CEDIA) is an organisation of experienced companies involved in the design andcables cables installation of electronic systems for the home. A number of products for home automation and building control are offered from stock. Please see page 40-41.

Tel: 01727 840 841

Fax : 01727 840 842

FS

FS

cables

cables

FS

cables

FS

cables


172

TECHNICAL Index

318-TQ

137

A Access Control Alarm Cables Antennax™ Feeder Coaxial Armoured Data & Coaxial Cables AUDIO CABLES AWG / Metric Conversion Chart

56 58 38-39 61 49-53 164

B BFOU Instrumentation to IEC 60092-376 BFOU Power to IEC 60092-353 Broadcast & Camera Coaxial BS 5467 Armoured PVC Power 0.6/1kV BS 6724 Armoured LSHF Power 0.6/1kV BS 6883 0.6/1kV Shipwiring Power BS 6883 657-SW4 Unarmoured Shipwiring Instrumentation BS 6883 658-SW4 Armoured Shipwiring Instrumentation BS 7917 0.6/1kV Shipwiring Power Fire Resistant BS 7917 657M-SW4 Unarmoured Shipwiring Instrumentation - Fire Resistant BS 7917 658M-SW4 Armoured Shipwiring Instrumentation - Fire Resistant BUS CABLES

116-117 114-115 32 97 98 102-103

cables cables

FS

FS cables

6-27 42 90 88-89 43 36, 60 52

E Echelon LonWork System Cabling Equipment Wire LSHF

44 95

F FIRE & SECURITY CABLES Fire Alarm Cable Standard & Enhanced Flat PVC Cables 122 Flat Speaker Cables FT Data & Coaxial

54-61 54, 63 50 55, 63

G 106-107

GLANDS G-Temp 600

144-146 136

108-109

H 110-111 112-113 42-48

Cable Standards Cross Reference Chart 172 CAN Bus Cables 42 Cat-3 Multipair 27 Cat-5 Multipair 27 Cat-5E UTP & FTP 24-25, 26, 60-61, 62 Cat-6A UTP & FTP 25, 26, 60-61 Cat-7 25 CC-Link 1.10 FieldLink® Cables 43 COAXIAL CABLES 28-39 COLOUR CODE CHARTS 166-168 Composite Coaxial Cables 37, 57 CUSTOM MANUFACTURED CABLES 152-153 cables CW1044 Functional Earth 67 CW1128 External 68 CW1128/1198 Armoured 69 CW1308 LSHF Internal 65 CW1308 PVC Internal 64 CW1411 & CW1417 BT Drop Wire 67 CW1600 LSHF Limited Fire Hazard 66 CY PVC Bedded Screened Multicore 94

FS

DATA CABLES Databus® Foundation Fieldbus Cables Def-Standard LSHF Multicore Def-Standard PVC Multicore DeviceNet™ Cables Digital Satellite & Cable TV Coaxial DMX Cables

104-105

C

FS

D

H05RR-F H07RN-F HD Media Composite Cables HDMI Cables HF-120 Unscreened & HF-120-C Screened HF-120-C-TP Paired Screened HF-265 PUR Encoder HF-275 PUR Servo & Feedback Cables Hi-Flex HF-100 & HF-100-C PUR HIGH TEMPERATURE CABLES HOME AUTOMATION CABLES

118 119 40-41 53 126 127 128 129 124-125 130-137 40-41

I IBM Cables, Ethernet Cables & Twin-Ax Cables 22 Individual & Overall Screened Multipair Data Cable 24AWG RS422 Low Capacitance 18 Individually Screened Multipair Data Cable 20AWG & 18AWG 19 Individually Screened Multipair Data Cable 22AWG Low Capacitance RS422 13, 56, 60-61 Individually Screened Multipair Data Cable 24AWG Low Capacitance RS422 14, 60-61 Individually Screened Two Pair Data Cable 22AWG 12, 56, 60-61 Industrial Ethernet Cables 44 Instrumentation, Process Control & PLTC 21 Interbus Cables 44

www.fscables.com

sales@fscables.com


173

Index TECHNICAL J

P

J-H(St)H LSHF

71

Jointing Kits

147

J-Y(St)Y PVC

70

Parallel Speaker Cables

50

Photovoltaic cables

123

Pilz Safety Bus®

45

POWER CABLES

K

96-101

Profibus

KNX Cables

47

L LF-249

91

45

P-Temp 260

135

PTFE Single Cores

134

R

LiYCY PVC Screened Multicores

78-79

Reelflex PUR-H Drum Reeling

LiYCY-TP PVC Screened Pairs

80-81

RG Coaxial

LiYY Miniature Signal Cable LONDON UNDERGROUND APPROVED CABLES Lutron Grafik Eye Cables

74

RiserFlex 0.6/1kV86

62-63

RiserShield 0.6/1kV

46

M MARINE, OIL & GAS CABLES

102-117

Microphone Cables

49

Modbus

45

Mode Lighting Cables

46

Multicore Speaker Cables

51

Multiple Star Quad Cables

49

121

28-31, 60-61 87

ROBOTICS CABLES

124-129

RUBBER & CRANE CABLES

118-123

S Safe-T-Shield

99

SIGNAL & CONTROL CABLES

72-95

Silicone Multicores

132-133

Silicone Single Cores

130-131

Simmtronic Specs 3 & Lighting Multicores Single Core Enhanced Circuit Integrity

96

Single Pair Screened Data Cable

N Niltox™ LF-315 LSHF

84

Niltox™ LF-316 LSHF

85

Niltox™ LF-329 LSHF

82-83

Niltox™ LF-318 LSHF

75

Niltox™ LF-319 LSHF

76-77

NSHTöu Drum Reeling

142-143

Stranding Chart

165

Structured Wiring External Grade

26

S-Video Cables

53

SY PVC Steel Braided Multicore

92-93

FS

Telecom BT, TZC & RA Coaxial

Outdoor Control Cables

59

TELEPHONE CABLES

Outdoor Data & Coaxial Cables

60

THERMOCOUPLE CABLES

Overall Foil & Braid Screened Cored Data Cable RS232 & RS423

33 64-71

FS

Three Core Overall Screened Data Cable 16

TOOLS

Transducer & Load Cell Cablescables

Overall Foil & Braid Screened Data Cables RS232 & RS422

FS

154-174

cables

T TECHNICAL TABLES

O

52

SPIRAL CABLES

cables

100-101

8, 60

Snake Cables

120

NYY Unarmoured Power

48

138-141

FS 9

148-151

cables 23

20

Overall Foil & Braid Screened Paired Data Cable

U

24AWG RS485 Low Capacitance

Unscreened Paired Data Cable

15, 56, 60-61

Overall Foil & Braid Screened Paired Data Cable 17

Overall Screened Multicore Data Cable RS232

10

Overall Screened Multipair Data Cable RS232

11, 60

Tel: 01727 840 841

Y

FS

YY PVC

Fax : 01727 840 842

34-35

FS

cables

RS232 & RS422

7, 57 cables

URM Coaxial

59, 72-73

FS

cables

FS cables


174

TECHNICAL Cable Standards Cross Reference Chart Alternative Standard References

Conductor Stranding Standard IEC 60228

Description Conductor class, stranding and resistance for electric cables.

BS 6360

VDE 0295

Alternative Standard References

Flame Retardant Tests Standard

EN 60228

Requirements

IEC 60332-1-2

Vertical flame test on a single wire or cable.

EN 60332-1-2 EN 50265-2-1

IEC 60332-1 BS 4066-1 VDE 0482-265-2-1

IEC 60332-3-21 Cat A F/R

Bunched cables 40 minute burn test. 7.0 litres/metre of combustible material.

EN 60332-3-21 Cat A F/R

EN 50266-2-1 Cat A F/R

IEC 60332-3-22 Cat A

Bunched cables 40 minute burn test. 7.0 litres/metre of combustible material.

EN 60332-3-22 Cat A EN 50266-2-2 Cat A

IEC 60332-3A BS 4066 pt 3A VDE 0482-266-2-2 Cat A

IEC 60332-3-23 Cat B

Bunched cables 40 minute burn test. 3.5 litres/metre of combustible material.

EN 60332-3-23 Cat B EN 50266-2-3 Cat B

IEC 60332-3B BS 4066 pt 3B VDE 0482-266-2-3 Cat B

IEC 60332-3-24 Cat C

Bunched cables 20 minute burn test. 1.5 litres/metre of combustible material.

EN 60332-3-24 Cat C EN 50266-2-4 Cat C

IEC 60332-3C BS 4066 pt 3C VDE 0482-266-2-4 Cat C

IEC 60332-3-25 Cat D

Bunched cables 20 minute burn test. 0.5 litres/metre of combustible material.

EN 60332-3-25 Cat D

EN 50266-2-5 Cat D

Alternative Standard References

Fire Resistant Circuit Integrity Tests IEC 60331-21

Cables up to and including 0.6/1kV. 90 minutes minimum @ 750°C with fire.

IEC 60331-23

Data cables. 90 minutes @ 750°C with fire.

IEC 60331

VDE 0472 FE180

IEC 60331-25

Optical fibre cables. 90 minutes @ 750°C with fire.

IEC 60331-1 & 2

Cables up to and including 0.6/1kV. 120 minutes @ 830°C with fire & mechanical shock.

BS 6387 Cat C

Circuit integrity for 3 hours @ 950°C with fire.

BS 6387 Cat W

Circuit integrity for 30 minutes @ 650°C. 15 mins with fire, 15 mins with fire & water spray.

BS 6387 Cat Z

Circuit integrity for 15 minutes @ 950°C with fire & mechanical shock.

BS 8434-1 Standard

Circuit integrity for 30 minutes @ 850°C. 15mins fire, 15 mins with fire & water spray

BS 5839-1 Clause 26.2d

BS 8434-2 Enhanced

Circuit integrity for 2 hours @ 950°C. 60 mins fire & shock, 60 mins fire, shock & water spray.

BS 5839-1 Clause 26.2e

EN 50200 PH30

Circuit integrity for 30 minutes @ 850°C with fire and mechanical shock.

Similar to BS 8434-1 without the water spray test

EN 50200 PH60

Circuit integrity for 60 minutes @ 850°C with fire and mechanical shock.

EN 50200 PH120

Circuit integrity for 120 minutes @ 850°C with fire and mechanical shock.

cables

FS

FS

Halogen Gas Emission Tests

IEC 60754-1 cables

IEC 60754-2

cables

FS

IEC 61034-2

FS cables

Similar to BS 8434-2 without the water spray test

Alternative Standard References

Determination of halogen acid gas generation. Only suitable for cables with emissions of 5% and above. Not suitable for Low Smoke Halogen Free classification.

EN 50267-2-1

BS 6425-1

VDE 0482-267-2-1

Determination of the degree of acidity of gases evolved EN 50267-2-2 during combustion by measuring pH levels and conductivity. Suitable for Low Smoke Halogen Free classification.

BS 6425-2

VDE 0482-267-2-2

Alternative Standard References

Smoke Generation Tests

IEC 61034-1

IEC 60331-31

Test apparatus for measuring the smoke density of cables.

EN 61034-1

EN 50268-1

BS 7622-1

VDE 0482-1034-1

Test proceedure and requirements. Minimum of 60% light transmission.

EN 61034-2

EN 50268-2

BS 7622-2

VDE 0482-1034-2

www.fscables.com

sales@fscables.com


For additional FREE copies of 'the little red book', or if you would like one sent to a colleague, simply contact us using the methods below. Please provide us with the contact and company name, address, postcode and contact telephone number.

01727 840 841

www.fscables.com/littleredbook

littleredbook@fscables.com Text the word

CABLES to 65000

followed by your name & address

Texts are charged at your standard network rate. Your details are only used for catalogue dispatch and order fulfillment. They are not shared or disclosed with any third party.

www.fscables.com sales@fscables.com

OEM Sales: 01727 849 801 Contractor Sales: 01727 849 802 Wholesaler Sales: 01727 849 849

FS

FS

FS

cables

Great effort has been made to ensure the accuracy of the information in this booklet. However products may vary due to manufacturing changes, technical improvements and commercial factors. In particular, overall diameters and weights are given for guidance only and if critical, they should be confirmed at time of order.

Fax : 01727 840 842

FS

FS

cables

cables

FS

No part of this publication may be reproduced or replicated in any form without the express written permission of Caplink Ltd.

Tel: 01727 840 841

cables

FS

cables

All Trade Marks and Trade Names are acknowledged. Š Copyright Caplink Ltd 2010. All rights reserved.

cables

General Sales: 01727 840 841 Fax: 01727 840 842

FS

cables

FS Cables, Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX

cables


s

cables

S

FS

FS Cables Front Cover*:Layout 1

18/11/10

15:33

Page 1

the little

FS

red book

Issue 10

cables

the little red book

FS

cables

FS

FS

FS

FS

FS

Issue 10

FS Cables Alban Point, Alban Park, Hatfield Road, St. Albans, Herts AL4 0JX

cables

cables

cables

cables

cables

flexible and FSspecialist FS cables cables

FS Cables

Tel: 01727 840 841 Fax: 01727 840 842 www.fscables.com sales@fscables.com

cables


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.