Catalog Fte Networks

Page 1

Networks

November 2011 issue

Infrastructure for data networks



Evolving for the professional Since the beginning of Fte maximal in 1965 we have been growing in the market in an unstoppable way led by the best installers in the TV signal reception and distribution sector. Today, we want to support and lead the data installations market in the same way, making the trademark a guaranteed success for thousands of installers worldwide, who want to expand their business or who already know this technology.

Index Structured cabling Cables .................................................. 02 Patch cords ........................................... 04 Connectors • Keystone jack ............................. 06 • RJ45 .............................................. 08 19” patch panels ................................. 10 Telecommunication outlets .............. 12

Cabinets Server cabinets .................................. 14 Multipurpose cabinets ...................... 15 Wall cabinets ...................................... 16 Accessories ......................................... 17 Telecommunication cabinet kits ...... 18

Power distribution units Basic series .......................................... 21 Vertical series ...................................... 22 Remote series .................................... 23

Index of references ..................... 24



Cables Patch cords

Structured cabling

Connectors • Keystone jacks • RJ45 19” patch panels Telecommunication outlets


CAB LE S

Networks

C a bles The LAN cable is formed by four pairs of annealed and stretched copper, recovered by a protective colored plastic film. The twisted of the insulated pairs cancels the interferences from the external sources and the crosstalk between the adjacent pairs. The different constructions of cables determine their capacity of transmission.

Easy removal The design of 305 meter box allows for easy cable pulling with no kinks.

Complete solution The Fte Networks cables are completed with branches of related products, which are associated to each one of the construction and communication technologies. This provides complete solutions, from cables to the connectors, to pacth panels and other elements of the installation.

Regulation The cable reels of Fte Networks meet all standards of structured cable: TIA/EIA-568-B, EN 50.173, ISO 11.801, 2nd ed. ďƒœ Please check the available certificates in http://networks.ftemaximal.com

CENELEC AENOR TIA / EIA

Marked The cover marked allows the cable identification once the installation is done, likewise the cable cut due to its metric marked.

02. / Infrastructure for data networks

Structured cabling


CAB LE S

Networks

Articles chart for LAN cable, bare cooper Code

Reference

Description

2220300

CA-5E-U-1000FT-GY

Reel of LAN Cable cat. 5e U/UTP in PVC. Box 305 m. Grey color 24 AWG.

2220302

CA-6-U-1000FT-GY

Reel of LAN Cable cat. 6 U/UTP in PVC. Box 305 m. Grey color 23 AWG.

2220304

CA-6-U-1000FTLSZH-GY

Reel of LAN cat. 6 U/UTP in LSZH (halogen free). Box 305 m. Grey color 23 AWG.

2220305

CA-6-F-1000FTLSZH-GY

Reel of LAN cat. 6 F/UTP in LSZH (halogen free). Box 305 m. Grey color 23 AWG.

2220307

CA-6A-SF-1000FTLSZH-GY

Reel of LAN cable cat. 6A in LSZH (halogen free). Box 305m. Grey color, 23AWG

2220309

CA-7-SF-1000FTLSZH-GY

Reel of LAN cable cat. 7 in LSZH (halogen free). Box 305m. Grey color, 23AWG

CAT. 6 U/UTP and CAT. 6 F/UTP

CAT. 5e U/UTP Frequency (MHz)

RL (dB) min.

Attenuation (dB/100m) max.

NEXT (dB)

ACR (dB)

Frequency (MHz)

RL (dB) min.

Attenuation (dB/100m) max.

NEXT (dB)

ACR (dB)

1

17,0

2,03

62,30

60,30

1

20,0

2,02

74,30

72,28

4

18,8

4,04

53,26

49,20

4

23,0

3,78

65,27

61,49

8

19,7

5,76

48,75

43,00

8

24,5

5,32

60,75

55,43

10

20,0

6,46

47,30

40,80

10

25,0

5,95

59,30

53,35

16

20,0

8,24

44,30

36,10

16

25,0

7,55

56,24

48,68

20

20,0

9,26

42,78

33,50

20

25,0

8,47

54,78

46,31

25

19,3

10,41

41,33

30,90

25

24,3

9,51

53,33

43,83

31,25

18,6

11,72

39,87

28,20

31,25

23,6

10,67

51,88

41,20

62,5

16,5

16,99

35,36

18,40

62,5

21,5

15,38

47,36

31,98

100

15,1

21,97

32,29

10,30

100

20,1

19,80

44,30

24,50

250

17,3

32,84

38,33

5,48

Section 5e U/UTP

Section 6 U/UTP

CAT. 6A S/FTP

CAT. 7 S/FTP

Frequency (MHz)

RL (dB) min.

Attenuation (dB/100m) max.

NEXT (dB)

TCL (dB)

Frequency (MHz)

RL (dB) min.

Attenuation (dB/100m) max.

NEXT (dB)

TCL (dB)

4

23,0

3,8

78,00

30,00

4

23,0

3,7

78,00

30,00

8

24,5

5,3

78,00

28,00

8

24,5

5,2

78,00

28,00

10

25,0

5,9

78,00

27,00

10

27,2

5,9

78,00

27,00

16

26,0

7,5

78,00

26,00

16

25,0

7,4

78,00

26,00

20

26,5

8,4

78,00

22,00

20

25,0

8,3

78,00

22,00

31,5

27,5

10,5

78,00

20,00

31,5

23,6

10,5

78,00

20,00

62,5

29,0

15,0

75,50

19,00

62,5

21,5

14,9

75,50

19,00

100

30,0

19,1

72,40

17,00

100

20,1

19,0

72,40

17,00

200

31,5

27,6

67,90

/

200

18,0

27,5

67,90

/

300

32,4

34,3

65,24

/

300

34,2

34,2

65,24

/

500

33,5

45,3

60,73

/

600

50,1

50,1

60,73

/

Section 6 F/UTP

Section 6A & 7 S/FTP

Structured cabling

Infrastructure for data networks / .03


PAT C H C O R D S

Networks

Pa tc h c ords The patch cords are constructed of four pairs which, at the same time, are made of seven filaments of the highest purity copper. This makes them more malleable and they can be easily installed and adapted to the space restrictions inside the rack enclosures.

LSZH patch cords The cover of the patch cords from Fte Networks is always LSZH, which is the safety guarantee at any installation.

Individual packaging and labeling Individual labelling allows for traceability of the product from factory manufacture, to storage, right through to installation.

Own identification system - CCS Fte Networks has created a new economic and effective coding system that allows for individual identification of the installed patch cords. The patch cords are grey and have nine different sizes, in the range, therefore covering any application.

CENELEC AENOR TIA / EIA

04. / Infrastructure for data networks

Regulation The cable reels of Fte Networks meet all standards of structured cable: TIA/EIA-568-B, EN 50.173, ISO 11.801, 2nd ed. ďƒœ Please check the available certificates in http://networks.ftemaximal.com

Structured cabling


PAT C H C O R D S

Networks

Articles chart for patch cords

5e U/UTP

6 U/UTP

6 F/UTP

LSZH

Code

Reference

Description

2220010

PC-5e-U-MT-0.5GY

Patch cord RJ45-RJ45. 0,5 m

1/50

2220012

PC-5e-U-MT-1GY

Patch cord RJ45-RJ45. 1 m

1/35

2220013

PC-5e-U-MT-1.5GY

Patch cord RJ45-RJ45.1,5 m

1/30

2220014

PC-5e-U-MT-2GY

Patch cord RJ45-RJ45. 2 m

1/20

2220016

PC-5e-U-MT-3GY

Patch cord RJ45-RJ45. 3 m

1/15

2220018

PC-5e-U-MT-5GY

Patch cord RJ45-RJ45. 5 m

1/10

2220194

PC-5e-U-MT-7.5GY

Patch cord RJ45-RJ45. 7,5 m

1/15

2220195

PC-5e-U-MT-10GY

Patch cord RJ45-RJ45. 10 m

1/12

2220196

PC-5e-U-MT-15GY

Patch cord RJ45-RJ45, 15 m

1/10

Code

Reference

Description

2220080

PC-6-U-MT-0.5GY

Patch cord RJ45-RJ 45. 0,5 m

1/50

2220082

PC-6-U-MT-1GY

Patch cord RJ45-RJ45. 1 m

1/35

2220083

PC-6-U-MT-1.5GY

Patch cord RJ45-RJ45. 1,5 m

1/20

2220084

PC-6-U-MT-2GY

Patch cord RJ45-RJ45. 2 m

1/15

2220086

PC-6-U-MT-3GY

Patch cord RJ45-RJ45. 3 m

1/10

2220088

PC-6-U-MT-5GY

Patch cord RJ45-RJ45. 5 m

1/7

2220188

PC-6-U-MT-7.5GY

Patch cord RJ45-RJ45. 7,5 m

1/12

2220189

PC-6-U-MT-10GY

Patch cord RJ45-RJ45. 10 m

1/10

2220190

PC-6-U-MT-15GY

Patch cord RJ45-RJ45. 15 m

1/6

Code

Reference

Description

2220150

PC-6-F-MT-0.5GY

Patch cord RJ45-RJ45. 0,5 m

1/50

2220152

PC-6-F-MT-1GY

Patch cord RJ45-RJ45. 1 m

1/35

2220153

PC-6-F-MT-1.5GY

Patch cord RJ45-RJ45. 1,5 m

1/20

2220154

PC-6-F-MT-2GY

Patch cord RJ45-RJ45. 2 m

1/15

2220156

PC-6-F-MT-3GY

Patch cord RJ45-RJ45. 3 m

1/10

2220158

PC-6-F-MT-5GY

Patch cord RJ45-RJ45. 5 m

1/7

2220191

PC-6-F-MT-7.5GY

Patch cord RJ45-RJ45. 7,5 m

1/12

2220192

PC-6-F-MT-10GY

Patch cord RJ45-RJ45.10 m

1/10

2220193

PC-6-F-MT-15GY

Patch cord RJ45-RJ45. 15 m

1/6

Packaging

Packaging

Packaging

Note: more colors and technologies available for project.

Structured cabling

Packaging

Code

Reference

Description

2220226

CCS-WH

Color coding system, white

36/4320

2220228

CCS-BK

Color coding system, black

36/4320

2220230

CCS-YL

Color coding system, yellow

36/4320

2220232

CCS-RD

Color coding system, red

36/4320

2220234

CCS-BL

Color coding system, blue

36/4320

2220236

CCS-GN

Color coding system, green

36/4320

2220238

CCS-MC

Color coding system, multicolor

36/4320

Infrastructure for data networks / .05


CON N ECTOR S

Networks

K eys tone ja c k The distribution of the wires improves the insulation between the signals that are sent through them. In the same way, the minimum untwisted of the cable avoids the geometry loss of the pairs that would result into crosstalk effects that could damage the communication.

Connectors for each application The connector range from Fte Networks can be used in any installation. The keystone jacks are suitable for all the technologies that can be found in any installation. Tooless connectors,180ยบ, shielded or unshielded, for the different categories.

Individual packaging and labeling Individual labelling allows it makes possible the storage and traceability of the goods from the moment they go out from factory up to the installation. For easier logistics, ten keystone jacks are inside a larger bag, which is labelled also.

Versatility The universal anchorage system allows for adapting the connector to different products of the data network range, using only one connector, we can make connections in patch panels and telecommunication outlets.

Comunication security

CENELEC AENOR TIA / EIA

06. / Infrastructure for data networks

The construction of the connector, which is adapted in order to lodge the connectors RJ11, RJ12 and RJ45, assures communication reliability higher than the indicated in the corresponding standard (ISO 11801, 2nd ed.; EN50.173)

Structured cabling


CON N ECTOR S

Networks

Articles chart for keystone jack Code

Category

2220200 2220201

5e UTP

2220202

Code

Category

2220204

Reference

Description

KJT-5e-U-WH

Tooless keystone jack

10/100

KJR-5e-U-WH*

Unshielded keystone jack 180º

10/100

KJK-5e-U-WH

Unshielded keystone jack 90º

10/100

Reference

Description

KJT-6-U-WH

Tooless keystone jack

10/100

KJR-6-U-WH*

Unshielded keystone jack 180º

10/100

Reference

Description

KJK-6-F-SI

Shielded keystone jack 90º

10/100

KJR-6-F-SI*

Shielded keystone jack 180º

10/100

Packaging

Packaging

6 UTP 2220299

Code

Category

2220296

Packaging

6 FTP 2220297

Code

2220205

Reference

KJR-6A-F-SI

Packaging

Description

Shieded cat.6A keystone jack 180º

10/100

Packaging

Code

Reference

Description

0705250

HT

Insertion and cutting tool for keystone jack

1

* Compatible with patch panel ref. PPC-U/F (see page 11) Structured cabling

Infrastructure for data networks / .07


CON N ECTOR S

Networks

R J 45 C onnec tor The RJ45 connector has over time adapted to the different technologies, being a valid standard, in its external frame, for categories 4, 5, 5e and 6. Two diagrams can define the wiring standard of the wires: 568A or 568B. The most used one is the 568B

Easy assembling The connectors belonging to the category 6 have assembling guides that make the connection easy and guaranty a quality communication.

Individual packaging and labeling Each bag has only 10 units for its correct storage and traceability. In the case of connectors with category 6, the 10 guides are separated in individual bags.

Regulation All the connectors RJ45 are designed and manufactured for a longer life than the one set in the current standard.

CENELEC AENOR TIA / EIA

Connection standards in connectors RJ45 568B

The wiring standards for RJ45 connectors can be wither 568A or 568B for each installation, it is essential to make.

568A

08. / Infrastructure for data networks

Structured cabling


CON N ECTOR S

Networks

Articles chart for RJ45 connector Code

Category

2220208

5e UTP

RJ45-5e-U

Unshielded RJ45 plug 23&26 AWG

10/1200

2220207

6 UTP

RJ45-6-U

Unshielded RJ45 plug 23&26 AWG

10/1200

2220209

6 FTP

RJ45-6-F

Shielded RJ45 plug 23&26 AWG

10/1200

Code

2220306

Reference

HT3

Reference

Description

Description

Packaging

Packaging

Tool to crimp RJ45 connectors

1

Articles chart for RJ45 protector Code

568B

568A

Structured cabling

Reference

Description

Packaging

2220210

RJBT-WH

Color protector for RJ45 white

25/1400

2220212

RJBT-BK

Color protector for RJ45 black

25/1400

2220214

RJBT-YL

Color protector for RJ45 yellow

25/1400

2220216

RJBT-RD

Color protector for RJ45 red

25/1400

2220218

RJBT-BL

Color protector for RJ45 blue

25/1400

2220220

RJBT-GN

Color protector for RJ45 green

25/1400

2220222

RJBT-GY

Color protector for RJ45 grey

25/1400

2220224

RJBT-MC

Color protector for RJ45 multicolor

25/1400

Infrastructure for data networks / .09


1 9 � PAT C H PA N E L S

Networks

19� pa tc h pa nels All the input and output lines of the Network devices go through a connection panel that makes easier the management and modification of the installation. This also reduces usage of female RJ45 connector which are integrated in active devices. These connectors are often difficult to replace.

Wide offer Fte Networks has a wide range of patch panels suited to any installation requirement. From the classic pre-connected panels, up to the new concept of modularity. In the new modular panel, several technologies (category 5e and category 6, shielded or unshielded) can be installed, even different materials in a near future, including optical fiber. This is possible thanks to the empty panels and the 180Âş keystone jacks that Fte Networks has in its catalogue.

Back support The new modular panel can be complemented by a back support for a better organization and layout of the wiring.

Enlargement of the installation The modular panels allow the installation to expand as it needs.The installer only has to install what is required at anytime. It is possible to cover holes until needed.

10. / Infrastructure for data networks

Structured cabling


1 9 ” PAT C H PA N E L S

Networks

Articles chart for loaded patch panels Code

Category

Reference

Description

2220280

5e UTP

PPC-5e-U-12

Patch panel 19” not shielded 12 ports

1

2220282

5e UTP

PPC-5e-U-24

Patch panel 19” not shielded 24 ports

1

2220284

5e UTP

PPC-5e-U-48

Patch panel 19” not shielded 48 ports

1

Code

Category

Reference

Description

2220286

6 UTP

PPC-6-U-12

Patch panel 19” not shielded 12 ports

1

2220288

6 UTP

PPC-6-U-24

Patch panel 19” not shielded 24 ports

1

2220290

6 UTP

PPC-6-U-48

Patch panel 19” not shielded 48 ports

1

Code

Category

Reference

Description

2220294

6A FTP

PPC-6A-F-24

19” patch panel shielded 24 ports, cat. 6A

Packaging

Packaging

Packaging 1

Articles chart for unloaded patch panels Code

Category

Reference

Description

Packaging

2220293

5e-6 UTP-FTP

PPC-U/F

Unloaded unshielded 24 ports 19” patch panel

1

2220295

-

PPC-BK*

Bracket for unloaded 24 ports 19” patch panel

1

NOTE: the compatible keystone jacks for this patch panel are KJR-5e-U-WH, KJR-6-U-WH, KJR-6-F-SI, KJR-6A-F-SI (see page 07) *(Bracket essential in FTP installations)

Structured cabling

Code

Category

Description

0705258

PK

Insertion plastic knife

Packaging 1

Infrastructure for data networks / .11


T E L E C O M M U N I C AT I O N O U T L E T S

Networks

T elec ommunic a tion outlet s The connection between the computer or the data network equipments and the net is usually made thought a fixed element on the wall. This element constitutes the final point of permanent data network. It is one of references when certifying the installation.

It includes everything we need The telecommunication outlets without connector include the necessary elements in order to make the installation easier: bridles and screws.

Versatile and efective Keystone jack from any technology (category 5e, category 6, shielded as well as unshielded) can be installed inside the empty telecommunication outlets. The connectors that should be used are the 90ยบ models or the tooless keystone jacks.

Articles chart for Telecommunication outlets

12. / Infrastructure for data networks

Code

Reference

Description

Packaging

2220262

SMB-1-WH

Unloaded surface mount box single port

1/80

2220264

SMB-2-WH

Unloaded surface mount box dual ports

1/40

Code

Reference

Description

2220250

SMB-5e-U-1-WH

Wall outlet RJ45 individual Cat. 5e

1/10

2220252

SMB-5e-U-2-WH

Wall outlet RJ45 twin Cat. 5e

1/10

Packaging

Structured cabling


Networks

CON ECTOR E S

Server cabinet Multipurpose cabinet

Cabinets

Structured cabling

Wall cabinet Accessories Telecommunication cabinet kits

Infrastructure for data networks / .017


CAB I N ETS

Networks

S er v er c a binet Servers and network devices often have special requirement for weights and heat dissipation. The strong structure and wide ventilation areas in the pont and rear back doors of the Fte Networks server cabinets are perfect for this purpose.

Mounting profile with unit mark and 130 degree hinge

Static load up to 1.000 Kg According to standards ASI/EIA RS-310-D, IEC297-2, DIN41491 part 1; DIN41494 part 7, GB/T3047.2-92 standard, ETSI standard compatible Single opened ambossed front door (ventilated area up to 65%) Side panels with fasten opened bolt

Foam glue and side mounting angle

Fast adjustment feet 130ยบ opening door The depth is adjustable (take 25MM as unit), the height of capacity is adjustable (take 1U as unit) Material: cold rolled steel, 2mm thickness frame Color: black RAL9004 in stock, grey RAL7044 on request

Top cover with the pastic cover entry

Accesories included: 40 sets M6 screws and nuts, 4 elevation feet, 4 heavy duty castors

Articles chart for server cabinet

Code

Reference

Description

Dimension*

0050940

SER 61022

Server Cabinet 22U

600x1000x1200 mm

0050942

SER 61042

Server Cabinet 42U

600x1000x2000 mm

0050944

SER 61047

Server Cabinet 47U

600x1000x2200 mm

0050946

SER 81042

Server Cabinet 42U

800x1000x2000 mm

0050948

SER 81047

Server Cabinet 47U

800x1000x2200 mm

If other measures or configurations are required, ask Fte maximal *(Width x Depth x Height) 14. / Infrastructure for data networks

Cabinets


CAB I N ETS

Networks

M ultipurpos e c a binet For data distribution equipment, such as switches and patch panels, the multiple purpose cabinet is the perfect solution. Available in a variety of dimensions, it has a capacity up to 500 kilos, which makes it suitable for a wide range of applications.

Static load up to 500 Kg According to standards ASI/EIA RS-310-D, IEC297-2, DIN41491part 1; DIN41494 part 7, GB/T3047.2-92 standard, ETSI standard compatible Glass front door, single flat steel rear door Side panels with fasten opened bolt Fast adjustment feet Material: cold rolled steel, 2mm thickness frame Color: black RAL9004 in stoc, grey RAL7044 on request Accesories included: top cover fan, 3 fixed shelfs, 40 sets M6 screws and nuts, 4 elevation feet, 4 heavy duty castors

Articles chart for Multipurpose Cabinet

NOTE: References for assembled version: MUL XXXXi References for disassembled version: MUL XXXXo (see articles chart page 24) Cabinets

Code

Reference

Description

Dimension*

0050950

MUL 6622i

Multipurpose Cabinet 22U

600x600x1200 mm

0050952

MUL 6632i

Multipurpose Cabinet 32U

600x600x1600 mm

0050954

MUL 6642i

Multipurpose Cabinet 42U

600x600x2000 mm

0050956

MUL 6922i

Multipurpose Cabinet 22U

600x900x1200 mm

0050958

MUL 6932i

Multipurpose Cabinet 32U

600x900x1600 mm

0050960

MUL 6942i

Multipurpose Cabinet 42U

600x900x2000 mm

0050962

MUL 8842i

Multipurpose Cabinet 42U

800x800x2000 mm

If other measures or configurations are required, ask Fte maximal *(Width x Depth x Height) Infrastructure for data networks / .15


CAB I N ETS

Networks

W a ll c a binets It is perfect for small installations and offices, suitable also for TV signal reception systems and distribution devices from Fte Networks.

Articles chart for single section wall cabinets Static load up to 60 Kg

Code

Reference

Description

Dimension*

0051002

WSB 646i

Wall Cabinet Single section 6U

600x450x368 mm

0051004

WSB 649i

Wall Cabinet Single section 9U

600x450x501 mm

0051006

WSB 6412i

Wall Cabinet Single section 12U

600x450x635 mm

Material: cold rolled steel, 2mm thickness frame

0051008

WSB 6415i

600x450x769 mm

Color: black RAL9004 in stock, grey RAL7044 on request

Wall Cabinet Single section 15U

0051010

WSB 6418i

Wall Cabinet Single section 18U

600x450x901 mm

0051012

WSB 6422i

Wall Cabinet Single section 22U

600x450x1068 mm

According to standards ASI/EIA RS-310-D, IEC297-2, DIN41491 part 1; DIN41494 part 7, GB/T3047.2-92 standard, ETSI standard compatible Glass front door, single flat steel rear door 180ยบ front door openning Side panels with fasten opened bolt

Accessories included: 10 sets screws and nuts in 6u to 12u cabinets and 20 sets screws in 15u to 22u cabinets.

If other measures or configurations are required, ask Fte maximal *(Width x Depth x Height)

Articles chart for double section wall cabinets Static load up to 60 Kg According to standards ASI/EIA RS-310-D, IEC297-2, DIN41491 part 1; DIN41494 part 7, GB/T3047.2-92 standard, ETSI standard compatible Double section body, the main can be openned up to 120ยบ Glass front door, single flat steel rear door 180ยบ front door openning

Code

Reference

Description

Dimension*

0051014

WDB 666

Wall Cabinet Double section 6U

600x600x368 mm

0051016

WDB 669

Wall Cabinet Double section 9U

600x600x501 mm

0051018

WDB 6612

Wall Cabinet Double section 12U

600x600x635 mm

0051020

WDB 6615

Wall Cabinet Double section 15U

600x600x769 mm

0051022

WDB 6618

Wall Cabinet Double section 18U

600x600x901 mm

Side panels with fasten opened bolt Color: black RAL9004 in stock, grey RAL7044 on request Accesories included: 10 sets screws and nuts in 6u to 12u cabinets and 20 sets screws in 15u to 22u cabinets. 16. / Infrastructure for data networks

If other measures or configurations are required, ask *(Width x Depth x Height)

Cabinets


CAB I N ETS

Networks

A c c es s or ies A wide range of accessories are available for 19” cabinets from Fte Networks. This provides a complete solution for an organized and effective installation.

Articles chart for accessories

PH1T

PH1S

Reference

Description

2220310

PH 1T

Cable manager with cover 1U

2220312

PH 1S

Cable manager 19” without cover 1U

2220314

BRK 30

Fixed shelf, 30 cm, 2U

2220316

BRK 40

Fixed shelf, 40 cm, 2U

0051046

BRK EX 60

Removable shelf 600 mm

0051054

BRK EX 80

Removable shelf 800 mm

0051056

BRK EX 90

Removable shelf 900 mm

0051050

BRK EX D60

Double removable shelf 600 mm

0051058

BRK EX D80

Double removable shelf 800 mm

0051060

BRK EX D90

Double removable shelf 900 mm

0051048

BRK F 60

Heavy load sliding self, 600 mm

0051062

BRK F 80

Heavy load sliding self, 800 mm

0051064

BRK F 90

Heavy load sliding self, 900 mm

2220320

BER 8ALS

Aluminum multi-socket 19” with on/off switch

2220318

CTTR 24

Set screws and nuts

0050917

VNT

Cooling fan (unit)

0051052

TERM DIG

Digital temperature unit

0051032

ELEV SET

Elevation set (4 feet + 4 wheels)

0051034

TP 1U

Metal cover 1U

0051036

TP 2U

Metal cover 2U

0051038

TP 3U

Metal cover 3U

0051040

TP 4U

Metal cover 4U

0051042

ESC RACK

Brush panel

0051044

GC RACK

Cable ring

0051078

IGCK

Individual grounding connection kit

BRKEX60

BRK40

BRKEXD60

BRKF60

BER8ALS

TERMDIG

CTTR24

ELEVSET

VNT

TP4U

ESCRACK

Cabinets

Code

GCRACK

IGCK

Infrastructure for data networks / .17


CAB I N ETS

Networks

Telecommunication cabinet kits Fte Networks has created the following kits for an easier selection of material. The installer can request all the elements included in one kit just giving the code for the kit needed.

CATEGORY 5e K48P-5e: 48 ports cabinet kit Code: 0051066

15U cabinet, 450 mm 48 ports patch panel Cable manager without cover Fixed shelf Aluminum multi-socket 48 Patch cords 1 m

K24P-5e: 24 ports cabinet kit Code: 0051068

9U cabinet, 450 mm 24 ports patch panel Cable manager without cover Fixed shelf Aluminum multi-socket 24 Patch cords 1 m

K12P-5e: 12 ports cabinet kit Code: 0051070

6U cabinet, 450 mm 12 ports patch panel Cable manager without cover Aluminum multi-socket 12 Patch cords 1 m

CATEGORY 6 K48P-6: 48 ports cabinet kit Code: 0051072

15U cabinet, 450 mm 48 ports patch panel Cable manager without cover Fixed shelf Aluminum multi-socket 48 Patch cords 1 m

K24P-6: 24 ports cabinet kit Code: 0051074

9U cabinet, 450 mm 24 ports patch panel Cable manager without cover Fixed shelf Aluminum multi-socket 24 Patch cords 1 m

K12P-6: 12 ports cabinet kit Code: 0051076

6U cabinet, 450 mm 12 ports patch panel Cable manager without cover Aluminum multi-socket 12 Patch cords 1 m

NOTE: The products included in the kit are supplied disassembled.

18. / Infrastructure for data networks

Cabinets


Power Distribution Units

Basic series Vertical series Remote series


POWE R D I STR I B UTION U N ITS

Networks

Power Distribution Units (PDU) Due to the electrical supplying of the active devices in a network, the cabinets must use an element known as PDU: A device that centralizes and makes the electrical distribution in the cabinet easier. Nowadays the computing services are becoming more and more professional and communication systems have to guarantee a non stop service, therefore the PDU takes on a higher relevance by offering different setting up, which provides higher control and information over the installation.

For all levels From the simplest installations up to the most sophisticated ones, there is a PDU suitable for each need.

Setting up Fte Networks has a stock of articles that covers the most of the applications. Besides, there are a lot of possible settings up according to the demands of the projects with specifics needs: kind of socket, length of the input cable, power available, vertical/ horizontal layout, etc. Please contact to Fte Networks for further information about terms and conditions.

Great power There is a high number of settings up adapted up to 32A power with section of input cable of 6mm2 for the cabinets that hold devices with high consumption.

Regulation All the PDUs of Fte Networks obey the mechanical and electrical requirements that the current law demands. The high quality materials as well as the used inner connections, make PDUs Fte Networks lasting and secure devices.

20. / Infrastructure for data networks

Power Distribution Units


Networks

POWE R D I STR I B UTION U N ITS

Ba s ic s eries The basic series of Fte Networks incorporate, over the traditional power distribution units, multiple functionalities for the supervision of the consumption and protection, very useful for those installations that have more advanced needs than the traditional ones.

“Anti disconnection� design In order to solve the problem of the easy disconnection of the computing outlet IEC320 C14 in applications with a high wiring density, we have designed an easy and useful system that avoids it.

Count on the necessary outlets The small size of the IEC320 C14 outlet, compared to other outlets of regular usage, allows having a higher number of devices being fed from the same PDU. We must keep always in mind the maximum nominal electricity that can run through the device.

Articles chart for Basic series

Power Distribution Units

Code

Reference

Description

0052000

BA 6 AMP

Basic PDU, 16A, 6xDIN49440+ ammeter

0052002

BA 8 SV

Basic PDU, 16A, 8xDIN49440+ surge protection

0052004

BA 6 MG

Basic PDU, 16A, 6xDIN49440+ circuit breaker

0052006

BA 8 FL

Basic PDU, 16A, 8xDIN49440+ fuse+light indicator

0052008

BA 10 FL

PDU Basic, 16A, 10xIEC320 C13+ fuse+light indicator

0052010

BA 10 SW

PDU Basic, 16A, 10xIEC320 C13+ circuit breaker

Infrastructure for data networks / .21


POWE R D I STR I B UTION U N ITS

Networks

Vertic a l s eries The vertical devices series are perfect for setting a modular and versatile installation. The number of power outlets installed could grow according to the growing of the installation without the need of switching off any device thanks to its guides and the modular basis system, which allow “hot-swap� connection.

Redundant power supply The Vertical series allows the installation to get the power from two different power lines. So, there will be just one power supply distributor in the cabinet, which ensures the electrical supply redundancy to the active devices in the data network.

L1

L2

Also, it allows balancing the charges very easily: we only have to turn upside down the modular base.

High number of outputs The vertical series consist in a device that is designed in order to allow the electrical connection to a high number of devices. The size of the main guide restricts its usage to cabinets with a height of 42U and 47U.

Articles chart for Vertical series

22. / Infrastructure for data networks

Code

Reference

Description

0052100

VE G 16-1

Vertical PDU, 6 slots guide, 16A, single input

0052102

VE G32-1

Vertical PDU, 6 slots guide, 32A, single input

0052104

VE G16-2

Vertical PDU, 6 slots guide, 16A, double input

0052106

VE G32-2

Vertical PDU, 6 slots guide, 32A, double input

0052108

VE MC13-5

Vertical PDU, 5xIEC320 C13 socket module

0052110

VE MC19-4

Vertical PDU, 4xIEC320 C19 socket module

0052112

VE MSCHUKO-4

Vertical PDU, 4xDIN49440 socket module

Power Distribution Units


Networks

POWE R D I STR I B UTION U N ITS

R emote s er ies It is the most sophisticated series of the PDUs of Fte Networks. There are different set ups and monitoring and control options, so we can reach an individual control and monitoring for each one of the power outputs, setting the maximums and minimums for the alarm levels and setting up the sending of warnings.

Integration possibilities Information Exchange capacity in protocol SNMPv2. This protocol allows the control of the remote PDU unit to be done through IT software system.

SNMPv2

Articles chart for Remote series Code

Reference

Description

0052200

RE A8-16

A level, 16A, 8xIEC320 C13 sockets

0052202

RE B8-16

B level, 16A, 8xIEC320 C13 sockets

0052204

RE C8-16

C level, 16A, 8xIEC320 C13 sockets

0052206

RE D8-16

D level, 16A, 8xIEC320 C13 sockets

0052208

RE D14-32

D level, 32A, 8xIEC320 C13 sockets, 4xIEC320 C19 sockets

0052280

RE T/H

T/H sensor

0052282

RE S

Smoke sensor

0052284

RE W

Water sensor

0052286

RE D

Door sensor

Remote management software

Control levels Features

A

Measurement of total consumption

                     

Measurement of individual consumption State monitoring for each ON/OFF State monitoring, sensors Alarms for total power limits Alarms for individual power limits Alarms for temperature/humidity limits Power Distribution Units

B

C

D

Infrastructure for data networks / .23


INDEX OF REFERENCES

Networks

Index of references Code

Reference

0052000

BA 6 AMP

0052002 0052004 0052006 0052008

Page

Code

Reference

Page

21

0051070

K 12P-5e

18

BA 8 SV

21

0051072

K 48P-6

18

BA 6 MG

21

0051074

K 24P-6

18

BA 8 FL

21

0051076

K 12P-6

18

BA 10 FL

21

2220202

KJK-5e-U-WH

07

0052010

BA 10 SW

21

2220296

KJK-6-F-SI

07

2220320

BER 8 ALS

17

2220201

KJR-5e-U-WH

07

2220314

BRK 30

17

2220297

KJR-6-F-SI

07

2220316

BRK 40

17

2220205

KJR-6A-F-SI

07

0051046

BRK EX 60

17

2220299

KJR-6-U-WH

07

0051054

BRK EX 80

17

2220200

KJT-5e-U-WH

07

0051056

BRK EX 90

17

2220204

KJT-6-U-WH

07

0051050

BRK EX D60

17

0050950

MUL 6622i

15

0051058

BRK EX D80

17

0050970

MUL 6622o

15

0051060

BRK EX D90

17

0050952

MUL 6632i

15

0051048

BRK F 60

17

0050972

MUL 6632o

15

0051062

BRK F 80

17

0050954

MUL 6642i

15

0051064

BRK F 90

17

0050974

MUL 6642o

15

2220300

CA-5E-U-1000FT-GY

03

0050956

MUL 6922i

15

2220305

CA-6-F-1000FT-LSZH-GY

03

0050976

MUL 6922o

15

2220307

CA-6A-SF-1000FT-LSZH-GY

03

0050958

MUL 6932i

15

2220302

CA-6-U-1000FT-GY

03

0050978

MUL 6932o

15

2220304

CA-6-U-1000FT-LSZH-GY

03

0050960

MUL 6942i

15

2220309

CA-7-SF-1000FT-LSZH-GY

03

0050980

MUL 6942o

15

2220228

CCS-BK

05

0050962

MUL 8842i

15

2220234

CCS-BL

05

0050982

MUL 8842o

15

2220236

CCS-GN

05

2220010

PC-5e-U-MT-0.5GY

05

2220238

CCS-MC

05

2220013

PC-5e-U-MT-1.5GY

05

2220232

CCS-RD

05

2220195

PC-5e-U-MT-10GY

05

2220226

CCS-WH

05

2220196

PC-5e-U-MT-15GY

05

2220230

CCS-YL

05

2220012

PC-5e-U-MT-1GY

05

2220318

CTTR 24

17

2220014

PC-5e-U-MT-2GY

05

0051032

ELEV SET

17

2220016

PC-5e-U-MT-3GY

05

0051042

ESC RACK

17

2220018

PC-5e-U-MT-5GY

05

0051044

GC RACK

17

2220194

PC-5e-U-MT-7.5GY

05

0705250

HT

07

2220150

PC-6-F-MT-0.5GY

05

2220306

HT3

09

2220153

PC-6-F-MT-1.5GY

05

0051078

IGCK

17

2220192

PC-6-F-MT-10GY

05

0051066

K 48P-5e

18

2220193

PC-6-F-MT-15GY

05

0051068

K 24P-5e

18

24. / Infrastructure for data networks

Index of references


Networks

INDEX OF REFERENCES

Index of references Code

Reference

2220152

PC-6-F-MT-1GY

2220154

PC-6-F-MT-2GY

Code

Reference

05

2220220

RJBT-GN

09

05

2220222

RJBT-GY

09

RJBT-MC

09

Page

Page

2220156

PC-6-F-MT-3GY

05

2220224

2220158

PC-6-F-MT-5GY

05

2220216

RJBT-RD

09

RJBT-WH

09

2220191

PC-6-F-MT-7.5GY

05

2220210

2220080

PC-6-U-MT-0.5GY

05

2220214

RJBT-YL

09

2220083

PC-6-U-MT-1.5GY

05

0050940

SER 61022

14

SER 61042

14

2220189

PC-6-U-MT-10GY

05

0050942

2220190

PC-6-U-MT-15GY

05

0050944

SER 61047

14

SER 81042

14

2220082

PC-6-U-MT-1GY

05

0050946

2220084

PC-6-U-MT-2GY

05

0050948

SER 81047

14

SMB-1-WH

12

2220086

PC-6-U-MT-3GY

05

2220262

2220088

PC-6-U-MT-5GY

05

2220264

SMB-2-WH

12

SMB-5e-U-1-WH

12

2220188

PC-6-U-MT-7.5GY

05

2220250

2220312

PH 1S

17

2220252

SMB-5e-U-2-WH

12

2220310

PH 1T

17

0051052

TERM DIG

17

TP 1U

17

0705258

PK

11

0051034

2220280

PPC-5e-U-12

11

0051036

TP 2U

17

TP 3U

17

2220282

PPC-5e-U-24

11

0051038

2220284

PPC-5e-U-48

11

0051040

TP 4U

17

VE G16-1

22

2220286

PPC-6-U-12

11

0052100

2220288

PPC-6-U-24

11

0052102

VE G32-1

22

VE G16-2

22

VE G32-2

22

2220290

PPC-6-U-48

11

0052104

2220294

PPC-6A-F-24

11

0052106

2220295

PPC-BK

11

0052108

VE MC13-5

22

VE MC19-4

22

2220293

PPC-U/F

11

0052110

0052200

RE A8-16

23

0052112

VE MSCHUKO-4

22

VNT

17 16

0052202

RE B8-16

23

0050917

0052204

RE C8-16

23

0051018

WDB 6612

0052206

RE D8-16

23

0051020

WDB 6615

16

WDB 6618

16

0052208

RE D14-32

23

0051022

0052280

RE T/H

23

0051014

WDB 666

16

WDB 669

16

0052282

RE S

23

0051016

0052284

RE W

23

0051006

WSB 6412i

16

WSB 6415i

16

0052286

RE D

23

0051008

2220208

RJ45-5e-U

09

0051010

WSB 6418i

16

WSB 6422i

16

2220209

RJ45-6-F

09

0051012

2220207

RJ45-6-U

09

0051002

WSB 646i

16

2220212

RJBT-BK

09

0051004

WSB 649i

16

2220218

RJBT-BL

09

Index of references

Infrastructure for data networks / .25


info: networks.ftemaximal.com

Legal Deposit:

MNNET11EN.0 June 11

+

BCN Distribuciones, S.A.U. Mogoda,110 Pol. Industrial Can Salvatella 08210 Barberà del Vallès (Barcelona) Tel. +34 93 729 27 00 Fax +34 93 729 30 73 ftemaximal@ftemaximal.com

SUBSIDIARIES DEUTSCHLAND Auf der Höhe 8 D-44536 Lünen Tel.: +49 231 8785 01 Fax: +49 231 8785 200 info@ftemaximal.de www.ftemaximal.de

FRANCE 16 ZAE Les Mouilles 74570 Groisy Tel. 04 50 68 80 17 Fax. 04 50 68 84 68 sav@ftemaximal.fr www.ftemaximal.com

ITALIA Via Edison, 29 42040 Calerno di Sant’Ilario d’Enza (RE) Tel. 0522 909701 Fax. 0522 909748 fte@fte.it www.ftemaximal.com

PORTUGAL Rua José Carlos Ary dos Santos A-das-Lebres (Loures) 2670-791 Santo Antão do Tojal Tel. 21.983.87.00 Fax. 21.983.87.09 ftemaximal@ftemaximal.pt www.ftemaximal.com

UNITED ARAB EMIRATES P.O. Box. 262442 Jebel Ali Free Zone Warehouse FZS5AB03 Dubai Tel. 00 971 4 886 5700 Fax. 00 971 4 886 5701 www.ftemaximal.ae


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.