Product Update Flyer - R32 Compact Cassette Range (NZ)

Page 1

PRODUCT UPDATE

Fujitsu General has expanded its R32 Compact Cassette range with the addition of the new AUTH24KVLA unit.

The extended range, now available in four models ranging from 3.2kW to 8.0kW heating capacity, operates with R32 refrigerant, which improves heat transfer and –compared to the commonly used R410A refrigerant –has a 67 per cent¹ lower ‘Global Warming Potential Factor’ whilst still maintaining the performance of the unit.

R32 Compact Cassette Range

R32 Refrigerant

Refrigerants play a vital role in how a heat pump/air conditioner works. Compared to the commonly used R410A refrigerant, R32 has a 67 per cent¹ lower ‘Global Warming Potential (GWP) Factor’ while still maintaining the performance of the unit.

High Energy Saving

Top level EER and COP is achieved with the new R32 PAC models.

Compact Design of Grille

Compact and stylish panel design suitable for 620mm x 620mm grid type ceiling.

Precise Temperature Control

Precise temperature control has been enabled by the ability to switch the temperature by half a degree via the wireless remote controller.

High Ceiling Mode

Can be installed up to a ceiling height of 3m (for AUTH12/18/24KVLA only).

Quiet Operation

Optimisation of the wing form (laminar wing type) and wing number (7 blades each) has resulted in quiet operation.

2-stage Turbo Fan

Produces two separate airflow streams allowing air to be distributed evenly across the heat exchanger.

Additional UART port for external system connection

Two UART ports are standard in the new R32 models to allow for simultaneous WLAN and external system connection.

FUJITSU GENERAL NEW ZEALAND
1 https://www.dcceew.gov.au/environment/protection/ozone/rac/global-warming-potential-values-hfc-refrigerants
R32 REFRIGERANT R32 REFRIGERANT EER 09 4.46 COP 09 4.21 12 3.89 12 3.85 18 3.45 18 3.51 24 3.29 24 3.62 620mm Adoption of laminar wing Spin direction Airflow direction Laminar wing Airflow runs through smoothly along the laminar wing Quiet No airflow separation Quiet Quiet No airflow separation Quiet Previous turbo fan Heat exchange efficiency 20%UP 1-stage 2-stage turbo fan + = 2-stage In the case of a previous fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. Fast Slow Wind velocity AOTH09/12KBTA AOTH18KBTA AOTH24KBTB AUTH09/12/18/24KVLA AR-REJ1E
AUTH24KVLA

Fujitsu General Assist

Fujitsu General's in-house customer care and technical support team, Fujitsu General Assist, offers a high level of technical and local aftersales support.

04 568 8761

Fujitsu General Assist deploys Fujitsu-trained technicians in Auckland and Christchurch. These technicians are well-equipped with the necessary tools and spare parts to enable them to resolve issues onsite, promptly. This offers customers a high first time fix rate and seamless experience.

Specifications

Fujitsu General believes in the quality and reliability of every product we sell. Our 6 year parts and labour warranty applies to residential applications when installed by a Fujitsu Accredited Installer. A standard 5 year warranty applies otherwise. Please visit www.fujitsugeneral.co.nz/warranty for more information.

Please refer to specifications before installation and servicing this product. Only persons and/or companies qualified and experienced in the installation, service and repair of refrigerant products should be permitted to do so. The purchaser must ensure that the person and/or company who is to install, service or repair this air conditioner has qualifications and experience in refrigerant products. Suitable access for warranty and service is required. Future improvement, specifications, designs of product and availability are subject to change without notice. All Capacity and Energy Efficiency ratings are based on AS/NZS3823.2. Running current is at rated conditions (AS3823) and does not include compressor start-up or variations in power supply and load conditions.

Note: Specifications are based on the following conditions.

Cooling: Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.

Heating: Indoor temperature of 20˚CDB / 15˚CWB, and outdoor temperature of 7˚CDB / 6˚CWB.

Pipe length: 7.5m; Height difference between outdoor unit and indoor unit: 0m. Voltage: 230V.

NEW MODEL Set Code SET-AUTH09KVLA SET-AUTH12KVLA SET-AUTH18KVLA SET-AUTH24KVLA Model No. Indoor unit AUTH09KVLA AUTH12KVLA AUTH18KVLA AUTH24KVLA Outdoor unit AOTH09KBTA AOTH12KBTA AOTH18KBTA AOTH24KBTB Power Source V / Ph / Hz 230 / 1 / 50 220 - 240 / 1 / 50 Capacity Cooling (Rated (Min - Max)) kW 2.50 (0.9 - 3.6) 3.50 (0.9 - 4.1) 5.00 (0.9 - 5.9) 7.10 (1.5-7.8) Heating (Rated (Min - Max)) kW 3.20 (0.9 - 4.5) 4.00 (0.9 - 5.1) 6.00 (0.9 - 7.1) 8.00 (1.4-8.4) Input Power Cooling (Rated (Max)) kW 0.56 (1.13) 0.90 (1.33) 1.45 (2.39) 2.16 (2.72) Heating (Rated (Max)) kW 0.76 (1.68) 1.04 (1.88) 1.71 (2.78) 2.21 (2.71) EER Cooling kW / kW 4.46 3.89 3.45 3.29 COP Heating kW / kW 4.21 3.85 3.51 3.62 Star Rating Cooling: Hot/Average/Cold 4 / 3.5 / 3.5 3.5 / 3 / 3 3 / 2.5 / 2.5 2.5 / 2.5 / 2.5 Heating: Hot/Average/Cold 3.5 / 3 / 2.5 3 / 2.5 / 2 3 / 2 / 1.5 3 / 2.5 / 2 TCSPF 1 Residential (Hot/Average/Cold) kW 5.804 / 5.126 / 5.179 5.206 / 4.74 / 4.862 4.666 / 4.325 / 4.474 4.401 / 4.187 / 4.365 HSPF2 Residential (Hot/Average/Cold) kW 5.064 / 4.575 / 4.108 4.822 / 4.268 / 3.714 4.574 / 3.954 / 3.376 4.58 / 4.044 / 3.533 Running current Cooling/Heating amps 3.0 / 4.0 4.2 / 5.0 6.2 / 7.3 9.6 / 9.7 Moisture Removal I/hr 0.7 1.2 2.0 3.4 Sound Pressure Level Indoor (Cooling) High/Quiet dBA 33 / 28 37 / 28 38 / 26 49 / 30 Indoor (Heating) High/Quiet 34 / 27 37 / 28 43 / 30 50 / 33 Outdoor (Cooling/Heating) High 41 / 46 47 / 48 48 / 49 54 / 50 Sound Power Level Outdoor High 59 61 62 69 Air Circulation Indoor (Cooling) High Fan I/sec 150 169 189 258 Indoor (Heating) High Fan 150 169 189 286 Dimensions H x W x D Indoor mm 245 x 570 x 570 Cassette grille 49 x 620 x 620 Outdoor 542 x 799 x 290 632 x 799 x 290 788 x 940 x 320 Net Weight Indoor kg 15.00 15.00 15.00 16.00 Cassette grille 2.30 2.30 2.30 2.30 Outdoor 32.00 32.00 36.00 53.00 Connection Pipe Diameter (Liquid/Gas) mm Ø6.35 / Ø9.52 Ø6.35 / Ø12.70 Pipe Length (Max (Precharged)) m 20 (15) 20 (15) 30 (20) 30 (30) Max Height Difference m 15 15 20 30 Operation Range Outdoor (Min - Max) Cooling °CDB -10 to 46 -10 to 46 -10 to 46 -10 to 50 Heating -15 to 24 -15 to 24 -15 to 24 -15 to 24 Refrigerant Type R32 R32 R32 R32 Charge g 850 850 1,020 1,500 1 Total Cooling Seasonal Performance Factor 2 Heating Seasonal Performance Factor
Copyright© 2024 Fujitsu General New Zealand. All rights reserved. PUCCNZ062024 fujitsugeneral.co.nz | contact@fujitsugeneral.co.nz | 04 568 8761 FUJITSU GENERAL NEW ZEALAND A SUBSIDIARY OF FUJITSU GENERAL LIMITED

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.