2nd Edition
VICTOR A Division of F.W. Webb Company
PROPANE EQUIPMENT CATALOG Y O U R S I N G L E S O U R C E F O R LP G A S P R O D U C T S
REGULATORS VALVES METERS CYLINDERS/TANKS SIGNS/DECALS GAUGES PIPE/TUBING/FITTINGS SEALANTS/CHEMICALS SERVICEMAN’S TOOLS PUMPS/COMPRESSORS
TABLE OF CONTENTS
iii
Acme Adapters, Connectors (Rego) ........................... 5, 6, 36, 37,41– 43, 46, 47 Adapters & Fittings (Marshall Brass) ...................... 46 Aim & Flame Lighters ............................................. 124 Alternate Energy Direct Fired LPG Vaporizers ............................... 148 Water Bath LPG Vaporizers ................................ 149 Anderson & Forrester Gas Orifices & Gauging Drills ............................ 121 Anode Bags, Magnesium (Corrpro).......................... 73 Anti-Freeze (Cryotek by Hercules) ......................... 119 Appliance Hand Truck ............................................... 70 Appliance Fittings, Portable (Paulin) .............. 109, 110 Ashcroft Pressure Gauges ........................................ 69 Ari Bee Bopper II .................................................... 124
Couplings, Quick Disconnect ............................ 86, 110 Crane Swing, and Lift Checks .................................. 39 Cylinders Steel, Aluminum (4.5 – 100#) (Worthington) ...... 64 Fork Lift Cylinders, Steel/Aluminum (Worthington) ................................................. 65 DOT/ASME (100#, 200#, 420#) (Worthington) ... 66 Cylinder Accessories Construction Collars ............................................ 66 Cylinder Cabinets (American Standard) .............. 68 Cylinder Hand Trucks ........................................... 70 Cylinder Vise (American Standard) ..................... 68 Methanol Injector ................................................. 70 OPD Valve Wrench Kit ......................................... 69 POL Valve Wrench Kit .......................................... 69 Portable Beam Scale (Fairbanks) ........................ 68 Pump Station Enclosure ...................................... 68 Tank Inverter ........................................................ 68 Vacuum/Purge Pump (Corken) .......................... 138
B Bacharach Test Equipment .................................... 129 Ball Valves .............................................. 31, 32, 33, 34 Black Malleable Fittings .................................. 111, 112 Brady Label Maker ................................................... 78 Brass Flare Fittings ......................................... 106, 107
D Dayco Bulk Hose............................................................. 98 Vapor Hose ........................................................ 108 Dormont Commercial Flexible Connectors ........................ 105 End Fittings ........................................................ 105 Residential Flexible Connectors ................. 104, 105 Drip Leg Packages ................................................... 98
C Cathodic Protection Cadweld System .................................................. 73 Underground Protector Tape ............................... 73 Underground Detector Tape ................................. 73 Charter Plastic Polyethylene Gas Pipe (Underground Only) ............................................. 98 Compressors Corken Compressors ......................................... 139 Corken Compressor Parts .......................... 140,141 Krug Compressors ............................................. 143 Combustion and Environmental Analyzers (Tif, UEI, Bacharach) .............................. 125 – 129 Conduit, Floppy Galvanized Steel (Tracpipe) ............ 96 Connectors, Flex Commercial Gas Appliance (Dormont) .............. 105 Residential Gas Appliance (Dormont) ........ 104, 105 Liquid/ Vapor, Stainless Steel Braided Hose (Flex Hose) ................................................... 145 Copper Tubing Gas-Tec Plastic Coated Tubing (Kamco) .............. 97 Standard Soft Copper Tubing .......................... 98 Corken Compressor ....................................................... 139 Compressor Parts ...................................... 140, 141 Coro-Flo® Turbine Pumps (Cylinder Filling) ....... 130 Coro-Flo® Pump Parts ......................... 131,132,133 Coro-Vac® Vacuum/Purge Pump ....................... 138 Coro-Vane® Pumps (Bulk Filling) ...................... 134 Coro-Vane® Pump Parts .................................... 135 Coro-Vane® Truck Pump ................................... 136 Coro-Vane® Truck Pump Parts .......................... 137 The VICTOR Propane Equipment Catalog
E Electric Motors, Explosion Proof (Weg) ................. 142
F Fittings Black Malleable .......................................... 111, 112 Brass AutoFlare® Fittings (Tracpipe) ................... 95 Brass Flare Fittings .................................... 106, 107 Brass Hose Barb Fittings .................................... 108 Forged Steel Fittings, Socket Weld............. 115, 116 Forged Steel Fittings, Threaded ................. 116, 117 Underground Plastic Fittings ................... 100 – 102 Portable Appliance Fittings ................ 103, 109, 110 Flare (Flame Engineering) ..................................... 124 Flanges, Socket Weld/Threaded/Blind .................... 116 Flashlights (Rayovac) ............................................ 124 Flexi-Hose, Flexible Gas Connectors ..................... 145 Forged Steel Fittings............................... 115, 116, 117 Full Circle Swivel Connectors ................................ 144
G Gaslights (Paulin Humphrey) ................................ 110 Gauges, Pressure (Ashcroft) .................................... 69 Gauges, Float (Rochester) ............................... 83 – 93 Gasoila Thread Sealant .......................................... 119 Gloves (Edmont, Bostic) ........................................ 124
TABLE OF CONTENTS
A
TABLE OF CONTENTS
iv
TABLE OF CONTENTS
H
M Manifolds, Pipe ................................................ 96, 101 Marshall Brass Extend-A-Flow™ ................................................ 103 Extend-A-Stay™ ................................................. 103 Regulators ........................................................... 17 Regulator Covers ................................................. 17 Type 1 Fittings & Adapters (OPD) ........................ 46 Type 1 RV Pigtails (OPD) ................................... 103 Match Lighter ......................................................... 124 Maxitrol Regulators ......................................... 13 – 16 Meters, Vapor (Invensys) Residential Gas Meters (Vapor) ........................... 60 Intermediate & Large Capacity Gas Meters .... 60, 61 How to Identify Parts ........................................... 62 Meter Accessories ............................................... 63 Meter Bars (McDonald) ........................................... 63 Meter Manifolds (R.W. Lyall) ................................ 101 Meter Valves (McDonald) Meter Valves (Ball Style) ...................................... 34 Meter Valves (Plug Style)..................................... 62 Meters (Liquid Controls) Positive Displacement Meters, Liquid .................................................... 147 Methanol Injector ..................................................... 70 Milwaukee Tools .................................................... 123 Motors, Electric (Explosion Proof) (Weg) .............. 142
Hand Cleaner .......................................................... 119 Hannay Reels, Hose Reels..................................... 146 Hansen, Gas-Mate Quick Disconnect Couplings .... 108 Hercules Chemicals, Misc. Sealants, Anti-Freeze, Thread Cutting Oil ...................................... 119, 120 Hose Bulk Hose, Liquid/Vapor (Dayco) ......................... 98 Vapor Hose, Grill (Dayco) .................................. 108 Humphrey/Paulin Indoor Gas Lights ..................... 110
I Invensys First Stage Regulators ........................................... 7 Vapor Meters ................................................. 60, 61 Second Stage Regulators ............................... 8 – 12
J Jamesbury Ball Valves ............................................. 33 Jomar Flare Ball Valves ............................................. 31, 32 Threaded Ball Valves ...................................... 31, 32 Ball Valve Accessories, Locking Devices .............. 31 Log Lighter Valve (Key or Floor Shutoffs) ............ 32
K Kamco Gas Outlet Box ................................................... 110 Plastic Coated Copper Tubing .............................. 97 Krug Compressors ................................................. 143
N Never•Seez Lubricant ............................................ 119 Nipples Schedule 40 Nipples .................................. 113, 114 Schedule 80 Nipples .......................................... 118
L Label Maker (Brady) ............................................... 78 Leak Detection Leak Detector (Sherlock, Hercules) .................. 120 Leak Detection Systems (Presto-Tap) ............... 120 Leak Tester Kit ................................................... 120 Leak Detector, Electronic (UEI) .......................... 127 Lighter (Aim & Flame) ........................................... 124 Lighter, Match ........................................................ 124 Liquid Controls Positive Displacement Meters (Liquid) .............. 147 Liqua-Tech Flow Meters (Liquid) ........................... 145 Lockable Ball Valve (Rub, Jomar) ...................... 32, 34 Lubricant (Never•Seez) ......................................... 119 Lyall, R. W., Underground Plastic Pipe Connections Lyall Risers ........................................................ 101 LYCOFIT® Installation Tools ............................... 102 LYCOFIT® Mechanical Fittings ........................... 100 Mechanical Tapping Tees ................................... 101 Meter Manifolds ................................................. 101
O Oil, Cutting (Hercules) ........................................... 119 Oil, Penetrating (Free All) ....................................... 119 Orifices Kits & Gauging Drill Kits (Anderson Forrester) ................................ 121, 122 Outlet Box (Kamco) ................................................ 110
P Paget Self-Cleaning Strainers ................................ 145 Paints (Sumter) ....................................................... 74 Paint Accessories ................................................ 75 Paint Coverage Chart ........................................... 75 Paulin Single High Pressure Appliance Hookups .......... 109 Multiple Portable Appliance Hookups ................ 109 Low Pressure Portable Appliance Hookups ....... 110 Pigtails, Rubber RV OPD (Marshall Brass) ............ 103 Pigtails, Rubber (Paulin)........................................ 109 Pigtails (Rego) ........................................................... 5
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
TABLE OF CONTENTS
Q Quality Steel Tanks Replacement Parts ............................................... 72 Tank Specifications .............................................. 71
R Rayovac Flashlights & Batteries ............................. 124 RectorSeal Sealants .............................................. 119 Reels (Hannay) ...................................................... 146 Rego Adapters, Connectors & Fittings ACME Adapters ......................................... 41, 42 CheckLok Adapters .......................................... 37 DOT Cylinder Filling Adapters . 37, 41– 43, 46, 47 Filler Hose Adapters ........................... 41– 43, 46 Fork Lift Filling Adapter ............................. 41, 47 Miscellaneous Adapters ..................... 37, 41 – 43 OPD Adapter .................................................... 46 POL Filling Adapter .................................... 46, 47 POL Swivel Adapters ................................... 5, 42 Unloading Adapters ................ 37, 41– 43, 46, 47 General Diagrams Bulk Storage Plant ........................................... 51 Delivery Truck (Bobtail) ................................... 50 Delivery Truck (Transport) ............................... 49 Domestic Installation ....................................... 49 Emergency Shut Off Valves ............................. 50 Miscellaneous Equipment Emergency Shutoff Controls (Cable, Pneumatic) 46 Fixed Liquid Level Gauges ............................... 48 The VICTOR Propane Equipment Catalog
Gauge Manometer ......................................... 125 High Pressure Test Gauge Adapter ................ 125 Manometer Adapters ....................................... 43 Pull-Away Valves ............................................. 45 Rotogauges ..................................................... 44 Sight Flow Indicators ....................................... 44 Spanner Wrench .............................................. 47 Water Manometer .......................................... 125 Regulators Automatic Changeover ...................................... 3 First Stage ......................................................... 1 High Pressure Pounds-to-Pounds ................. 3, 4 High Pressure Pounds-to-Pounds and High Temperature ..................................... 4 Second Stage ................................................ 1, 2 Second Stage for 2 PSIG ................................... 1 Second Stage, Special Application..................... 2 Single Stage for Portable Appliances ................. 3 Twin Stage ......................................................... 2 Regulator Accessories Brackets ............................................................ 6 Copper Pigtails .................................................. 5 Inlet Fittings ....................................................... 5 Tee Blocks ......................................................... 6 Tee Checks ........................................................ 6 Repair Kits ................................................... 52 – 57 Repair Kits, Obsolete ................................... 57 – 59 Valves Back Check ...................................................... 38 CheckLok ......................................................... 37 Combination .................................................... 48 Cylinder Valves, Liquid .............................. 18, 21 Cylinder Valves, OPD ....................................... 18 Cylinder Valves, POL .................................. 18,19 Emergency Shut Off (ESV) .............................. 45 Excess Flow ............................................... 35, 36 Filler ................................................................. 38 Flomatic ........................................................... 40 Fork Lift Valve ............................................ 19, 41 Globe and Angle ........................................ 27, 28 Hose End ................................................. 28 – 30 Internal ............................................................ 40 Multiport Relief ................................................ 26 MultiValve, 100# Cylinder .......................... 18, 21 MultiValve, DOT/ASME Cylinder .......... 20, 21, 22 Needle ............................................................. 48 Quick Actings (Snap Action) ...................... 29, 30 Relief ....................................................... 23 – 26 Service ...................................................... 19, 22 Transfer ..................................................... 29, 37 Underground ................................................... 20 Vent ................................................................. 47
TABLE OF CONTENTS
Pipe Polyethylene Underground Plastic Gas Pipe (Charter Plastics) ................................................ 98 Schedule 40 Black.............................................. 117 Schedule 80 Black.............................................. 117 Stainless Steel Corrugated Gas Pipe (Trac-Pipe) . 94 Pipe Wrap (Underground Cathodic Protection) ........ 73 Plastic Coated Copper Tubing (Kamco) .................... 97 POL Valve Wrench Kit .............................................. 69 Polyethylene Underground Tubing (Charter Plastics) . 98 Portable Beam Utility Scale (Fairbanks) .................. 68 Pressure Gauges (Ashcroft) ..................................... 69 Presto–Tap Leak Detection Systems ..................... 120 Pumps (Corken) Coro-Flo®, Stationary or Cylinder Filling Pump.. 130 Coro-Flo® Pump Parts ............................ 131 – 133 Coro-Vane® Stationary or Plant Pumps ............. 134 Coro-Vane® Pump Parts .................................... 135 Coro-Vane® Truck Pump ................................... 136 Coro-Vane® Truck Pump Parts .......................... 137 Pump Station Enclosure (American Standard) ........ 68 Pump Station Kits With Meter ..................................................... 81, 82 Without Meter ................................................ 79, 80
v
TABLE OF CONTENTS
vi
TABLE OF CONTENTS U
Regulators Invensys. ....................................................... 7 – 12 Marshals. ............................................................ 17 Maxitrol. ..................................................... 13 – 16 Rego. .............................................................. 1 – 4 Ridgid Tools ........................................................... 122 Rochester Gauges............................................ 83 – 93 Rub Lockable Ball Valve ........................................... 34
UEI, Testing Equipment ................................ 126 – 128
V Valves Back Check (Rego) .............................................. 38 Bronze Swing Check (Crane) ............................... 39 Bronze Horizontal Lift Check (Crane) ................... 39 Brass Ball Valves Jamesbury. ..................................................... 33 Jomar. ....................................................... 31, 32 CheckLok (Rego) ................................................. 37 Combination (Rego) ............................................ 48 Cylinder Valves, Liquid (Rego)....................... 18, 21 Cylinder Valves, OPD (Rego) ............................... 18 Cylinder Valves, POL (Rego) .......................... 18, 19 Emergency Shut Off (ESV) (Rego) ................ 45, 46 Excess Flow (Rego) ....................................... 35, 36 Filler (Rego) ......................................................... 38 Flomatic (Rego) ................................................... 40 Fork Lift Valve (Rego) .............................. 19, 23, 41 Globe & Angle Valves (Rego)......................... 27, 28 Hose End (Rego) ......................................... 28 – 30 Internal (Rego) .................................................... 40 Lockable Meter Valve (Jomar, Rub) .................... 34 Multiport Relief (Rego) ........................................ 26 MultiValve, 100# Cylinder (Rego) .................. 18, 21 MultiValve, DOT/ASME Cylinder (Rego) .. 20, 21, 22 Needle (Rego) ...................................................... 48 Pullaway .............................................................. 45 Quick Acting (Snap Action) (Rego) .............. 28 – 30 Relief (Rego) ............................................... 23 – 26 Service (Rego) ............................................... 19, 22 Transfer (Rego) ................................................... 29 Underground (Rego) ........................................... 20 Vent (Rego) ......................................................... 47 Vaporizers Direct Fired LPG (Alternate Energy) .................. 148 Water Bath LPG (Alternate Energy) ................... 149
S Scale, Portable Beam Utility (Fairbanks) ................. 68 Sealants Gasoila. ............................................................. 119 Hercules. ........................................................... 119 Rectorseal. ........................................................ 119 Signs/Decals (Douglas, Brady) ........................ 76 – 78 Sumter Coatings Accessories ................................................... 74, 75 Information .......................................................... 75 Paint .................................................................... 74 Stanley Tools ......................................................... 123 Strainers (Paget) ................................................... 145 Swing Check, 45 deg Swing and Horizontal Lift (Crane) ................................................................ 39 Swivel Hose (Full Circle) ....................................... 144
T Tanks (Quality Steel) ASME Storage Horizontal Tank ............................ 71 Tank Replacement Parts ...................................... 72 Tank Inverter (American Standard) ......................... 68 Tape, Teflon ............................................................ 119 Testing Equipment (Bacharach) ....................................................... 129 (TIF) ................................................................... 129 (UEI) ........................................................ 126 – 128 Tools Flare (Flame Engineering) ................................ 124 Gas Pressure Test Kit 0-30 PSI .......................... 120 Gauge Manometer (Rego) ................................. 125 High Pressure Gauge Adapter (Rego) ................ 125 Match Lighter .................................................... 124 Milwaukee Tools ............................................... 123 Rayovac Flashlights and Batteries ..................... 124 Ridgid Tools ...................................................... 122 Stanley Tools ..................................................... 123 TurboTorch......................................................... 124 Water Manometer (Rego) .................................. 125 Tracpipe, Corrugated Stainless Steel Flexible Gas Pipe .......................................... 94 – 96 Tubing Copper Tubing, Standard ..................................... 98 Copper Tubing, Plastic Coated (Kamco) ............. 97 Corrugated Stainless Steel Flexible Gas Pipe (Tracpipe) ....................................................... 94
W Wasp & Hornet Spray (Ari Bee Bopper II) ............. 124 Weg Electric Motors............................................... 142 Worthington Cylinders DOT/ASME Cylinders (100#, 200#, 420#) ........... 66 Forklift Cylinders, Steel and Aluminum ................ 65 LPG Cylinders, Steel & Aluminum (4.5#–100#) ... 64 Wrench Kits POL Wrench Kit ................................................... 57 OPD Wrench Kit ................................................... 57
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
TABLE OF CONTENTS Appendix A Cathodic Protection Basic Information .... 157 – 158 Cylinder Location Information Aboveground ASME Container Location Diagram (Figure 2) ................................................... 159 Cylinder Location Diagram (Figure 1) ............ 159 Location of LP Storage Containers ................ 152 Tables for Multiple Container Locations ........ 154 Underground ASME Container Location Diagram (Figure 3) ................................................... 160 DOT Cylinder Requalification ............................. 150 Filling Instructions for Pre-Purged Tanks ........... 151 Purging LP Cylinders (Methanol Injection Suggested Amounts) ..................................... 156 Safety Information on First Fill of LP Cylinder (Methanol Information) ................................. 155 Use of Liquid Volume Correctors ....................... 153 Appendix B Approximate Properties LP Gases ..................... 161 Orifice Conversion Multipliers for Natural Gas (Utility Gases) (Table F.3) ............................... 161 Orifice Sizing Chart for LP Gas (Table F.2) ......... 161 Orifice Sizing Chart for Natural Gas (Utility Gases) ................................................ 162 Appendix C Liquid Volume Tables, Computations & Graphs . 163, 164 Appendix D Installation of Vaporizers (Direct Fired, Waterbath, and Electric) ........... 165 Electrical Equipment .......................................... 165 Appendix E Leak Check Approved Methods................ 166 – 168
The VICTOR Propane Equipment Catalog
Pipe Sizing Tables Black Iron Pipe Schedule 40, 10’ – 400’ (LP) (11” WC) ........................................................... 170 Black Iron Pipe Schedule 40, 10’ – 2000’ (LP) (2 PSI) ............................................................... 169 Black Iron Pipe Schedule 40, 30’ – 2000’ (LP) (10 PSI) ............................................................. 169 Black Iron Pipe Schedule 40, 50’ – 2000’ (Nat) (1 PSI, .5 PSI Drop) .......................................... 176 Black Iron Pipe Schedule 40, 50’ – 2000’ (Nat) (2 PSI) ............................................................... 176 Black Iron Pipe Schedule 40, 50’ – 2000’ (Nat) (10 PSI) ............................................................. 176 Black Iron Pipe Schedule 80, 10’ – 400’ (LP) (11” WC) ........................................................... 171 Black Iron Pipe Schedule 80, 30’ – 2000’ (LP) (10 PSI) ............................................................. 170 Copper Tubing OD Refrigeration Tubing, 30’ – 400’ (LP) (11” WC) .................................................... 173 Copper Tubing OD Refrigeration Tubing, 30’ – 2000’ (LP) (10 PSI) ...................................................... 173 Copper Tubing Type K, 10’ – 400’ (LP) (11” WC) .. 171 Copper Tubing Type K, 30’ – 2000’ (LP) (10 PSI) .. 171 Copper Tubing Type L, 10’ – 400’ (LP) (11” WC) ... 173 Copper Tubing Type L, 10’ – 2000’ (LP) (2 PSI) ..... 173 Copper Tubing Type L, 30’ – 2000’ (LP) (10 PSI) ... 172 CSST Flexible Gas Pipe (Tracpipe), 5’ – 300’ (LP) (11” WC) ........................................................... 174 CSST Flexible Gas Pipe (Tracpipe), 5’ – 300’ (LP) (12” – 14” WC) ................................................. 174 CSST Flexible Gas Pipe (Tracpipe), 10’ – 500’ (LP) (2 PSI, 1 PSI Drop) ............................................ 174 CSST Flexible Gas Pipe (Tracpipe), 10’ – 500’ (LP) (2 PSI, 1.5 PSI Drop) ........................................ 175 CSST Flexible Gas Pipe (Tracpipe), 10’ – 500’ (LP) (5 PSI, 3.5 PSI Drop) ........................................ 175 Polyethylene Plastic Pipe IPS, 30’ – 200’ (LP) (10 PSI).............................................................. 172
TABLE OF CONTENTS
Appendices
vii
1
REGULATORS & ACCESSORIES
Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring no more than 1,500,000 BTU’s/hr. These regulators are factory set to reduce tank pressure to an intermediate pressure of approximately 10 PSIG. Inlet Outlet Orifice Part Number Connection Connection Size LV3303TR
LV3303TR
1/4" F. NPT
1/2" F. NPT
1/4"
Factory Delivery Pressure
Bonnet Vent Position
10 PSIG
Over Outlet
Vapor Capacity BTU/hr. Propane Webb# 1,500,000
162774
High Pressure First Stage Regulators LV4403 Series Provides accurate first stage regulation in two-stage bulk tank systems. These regulators handle vaporization of tanks up to 1200 gallons. Reduce tank pressure to an intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Also incorporated in multiple cylinder installations.
Part Number
LV4403TR9
LV4403SR4 LV4403TR4
Inlet Connection
LV4403SR96
Orifice Size
1/4" F. NPT 1/2" F. NPT
LV4403SR9 LV4403TR9
Outlet Connection
1/4" F. POL 3/4" F. NPT
LV4403TR96
Factory Delivery Pressure
Adjustment Range (PSIG)
Integral Relief Included
5 PSIG
1-5
187108
10 PSIG
5-10
187110
5 PSIG
1-5
10 PSIG
5-10
5 PSIG
1-5
187109
10 PSIG
5-10
162782
Yes
Vapor Capacity BTU/hr. Propane
2,500,000
Webb#
162780 162781
Second Stage Regulator for 2 PSIG Systems Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG. Systems that utilize this regulator use smaller than normal piping inside of the building. Part Number
Inlet Connection
Outlet Connection
Factory Orifice Size
Bonnet Delivery Pressure
Adjustment Range
Vent Position
1/2" F. NPT
LV4403Y4
162774
1/2" F. NPT
1,000,000 1/4"
LV4403Y46R 3/4" F. NPT
LV5503Y6
LV4403Y4
Vapor Capacity BTU/hr. Propane Webb#
2 PSIG @ 10 PSIG Inlet
1.8 - 2.5 PSIG
Over Inlet
3/4" F. NPT
LV5503Y8
250285 250286 2,200,000
1" F. NPT
9/32"
250287
Low Pressure Second Stage Regulators Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11� w.c. Ideal for medium commercial installation, multiple cylinder installations and normal domestic loads. Part Number
Inlet Connection
LV4403B66 LV4403B66R*
3/4" F. NPT 3/4" F. NPT
* Backmount Design
The VICTOR Propane Equipment Catalog
Factory Delivery Pressure
Adjustment Range
Vent Position
Vapor Capacity BTU/hr. Propane
Webb# 162775
1/2" F. NPT
LV4403B46R*
LV4403B66R
Orifice Size
1/2" F. NPT
LV4403B4 LV4403B46
Outlet Connection
#28 Drill
11" w.c. at 10 PSIG Inlet
162776 9" to 13" w.c.
Over Inlet
935,000
162777 162778 162779
REGULATORS & ACCESSORIES
Compact High Pressure First Stage Regulator
REGULATORS & ACCESSORIES
2
REGULATORS & ACCESSORIES Low Pressure Second Stage Regulators Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure. Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic systems. Part Number
Inlet Connection
LV5503B4
1/2" F. NPT
LV5503B6
Orifice Size
3/4" F. NPT
Factory Delivery Pressure
1/4"
11" w.c. at 10 PSIG Inlet
9/32"
1" F. NPT
LV6503B14
11/2" F. NPT
11/2" F. NPT
LV6503B16
2" F. NPT
2" F. NPT
Adjustment Range
Bonnet Vapor Capacity Vent BTU/hr. Position Propane
Webb# 162783
3/4" F. NPT
LV5503B8
LV5503B4
Outlet Connection
9" to 13" w.c.
1,600,000
Over Inlet
162784
81/2" - 14" w.c.
5/8"
2,300,000
187111
8,000,000
241847
9,750,000
243018
Low Pressure Second Stage Tobacco Barn Regulator Especially developed for drying barns in the tobacco industry. The 2503G regulator will supply steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn. LV5503G4
Part Number LV5503G4
Inlet Connection 1/2" F. NPT
Outlet Connection
Orifice Size
3/4" F. NPT
1/4"
Factory Delivery Pressure 15" w.c. at 15 PSIG Inlet
Adjustment Range
Bonnet Vent Position
Vapor Capacity BTU/hr. Propane
Webb#
8" to 18" w.c.
Above Inlet
1,750,000
193313
Compact Twin Stage Regulators This compact two-stage regulator is designed to reduce container pressure down to 11” w.c. delivery pressure. It is ideal for “on-site” cylinder applications, mobile homes and average domestic service including small ASME and 100 to 420 pound DOT cylinders.
LV404B4 Part Number
Inlet Connection
LV404B4 LV404B4V9 LV404B46
Outlet Connection
Orifice Size
Factory Delivery Pressure
Adjustment Bonnet Vent Bonnet Vent Range Position Position 2nd Stage 1st Stage 2nd Stage Down
1/2" F. NPT 1/4" F. NPT 3/4" F. NPT
LV404B46V9
.219
LV404B9 LV404B9V9 LV404B96
1/2" F. NPT
11" w.c. at 100 PSIG Inlet
9" - 13" w.c.
F. POL
LV404B96V9
3/4" F. NPT
Capacity BTU/hr. Propane
Accessories 1st Stage Vent Pipe-Away
Webb#
Over Outlet
162787
9 o’clock
9 o’clock
162788
Down
Over Outlet
162789
9 o’clock
9 o’clock
Down
Over Outlet
9 o’clock
9 o’clock
214088
Down
Over Outlet
187106
9 o’clock
9 o’clock
525,000
404PE
187105
LV404B23
Compact Twin Stage Regulators Designed for small domestic applications with flow requirements up to 200,000 BTU’s/ hr. These regulators are ideal for mobile homes, cottages and “on-site” cylinder applications.
Inlet Outlet Orifice Part Number Connection Connection Size LV404B23
1/4" F. NPT
LV404B29
F. POL
LV404B23V9
1/4" F. NPT
LV404B29V9
F. POL
1/2" F. NPT
.100
Factory Delivery Pressure 11" w.c. @ 100 PSIG Inlet
Adjustment Range 2nd Stage
Bonnet Vent Position 1st Stage
Bonnet Vent Position 2nd Stage
Rear
Over Outlet
Left
9 o’clock
9-13" w.c.
Accessories Capacity BTU/hr. 1st Stage Vent 2nd Stage Pipe-Away Vinyl Cover Propane
Bracket Webb# 162785
200,000
404PE
2302-55
2302-31
191088 162786 202171
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REGULATORS & ACCESSORIES
3
These combination automatic changeover, two stage regulators are especially suitable for homes, mobile homes, cottages, construction and other portable two cylinder installations. Empty containers may be replaced without interrupting customer’s gas service. Part Number
Service & Repair Indicator
7525B23
Integral
7525B4
Inlet Outlet Connection Connection 1/4" Inver ted
Flare
Factory Delivery Pressure
1/2" F. NPT
11" w.c.
Bonnet Adjustment Vent Range Position 9" - 13" w.c.
Over Outlet
Bracket Included
Capacity BTU/hr. Propane
Webb#
2302-31
200,000
162790
2503-22A
450,000
162792
7525B
Automatic Changeover Regulator Outfits These outfits contain the equipment required to provide automatic changeover regulation.
Part Number
Automatic Changeover Regulator Included
5726B23
7523B23
5727B23
7523B23
5754B4
7523B4
5755B4
7523B4
7523B23
7523B4
Inlet
Outlet
Pigtails Included-2
Bracket Included
Capacity BTU/hr. Propane
912FA20 1/4" Inverted Flare
1/2" F.
912FS20
NPT
912FA20
180,000 7519-60 500,000
912FS20
Webb# 162794 162795 186861 186862
Compact Regulators 302R
Part Number
302V
Type
These compact regulators are designed for smaller outdoor grills and fish cookers. It is intended for use on small portable appliances that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe systems per NFPA 58, 1995 edition. Outlet Orifice Connection Size
Inlet Connection
302
1/4" F. NPT
302S
Soft POL w/60 DMS Orifice
302R
Single Stage
302V 302V9LS
Factory Delivery Pressure
Adjustment Range
Bonnet Vent Position
Vapor Capacity BTU/hr. Propane Webb# 18637
3/8" F. NPT
1/4" F. NPT
No. 50 Drill
11" w.c. @ 100 PSIG Inlet
Small Vent Above Outlet 9-13" w.c.
125,000
186838
Drip Lip Above Outlet
Soft POL w/o Orifice
Drip Lip at 9 c’clock
162715
High Pressure Pounds-to-Pounds Regulator Industrial/Commercial Designed to reduce propane gas container pressure down to between 3 and 100 PSIG. Ideal for liquid or vapor service, they can be used in a variety of applications including salamander heaters, weed burning torches, fish cookers, tar pot heaters, and other industrial type services. Recommended Part Adjustment Inlet Outlet Delivery Pressure Number Method Connection Connection Range (PSIG)
597FA-D
597FA 597FB 597FC
Tee Handle
597FD
The VICTOR Propane Equipment Catalog
1/4" F. NPT
1/4" F. NPT
Capacity Determined @ Set Pressure of PSIG
1-15
10
Capacity BTU/hr. Propane
Webb#
1,750,000 162716
10-30
20
3,000,000
162717
20-45
30
3,500,000
162718
40-100
60
4,500,000
162719
REGULATORS & ACCESSORIES
Twin Stage Automatic Changeover Regulators
REGULATORS & ACCESSORIES
4
REGULATORS & ACCESSORIES High Pressure Pounds-to-Pounds Regulators Commercial/Industrial Designed to reduce LP gas and anhydrous ammonia container pressures to between 3 and 125 PSIG. Precision-built with a multi-million BTU capacity, the 1580M Series is perfect for such big, tough jobs as crop dryers, asphalt batch mixing plants, road building “tar wagons”, heat treating and other large industrial and commercial loads.
Part Number
1584MW
Service
AA1582MW
Adjustment Method
Recommended Delivery Pressure Range (PSIG)
Tee Handle
AA1582MK
Hex Head NH3
AA1582ML
Inlet & Outlet Connection
3-25
1/2" F. NPT
1584MH AA1584MW NH3
AA1584ML
Webb# 187087
30
2,400 CFH NH3
187086
60
2,600 CFH NH3
187085
3-30
20
7,000,000 BTU/hr. LPG
162800
25-50
30
7,500,000 BTU/hr. LPG
162799
60
8,000,000 BTU/hr. LPG
186810
3-25
20
4,500 CFH NH3
187089
20-50
30
4,800 CFH NH3
162412
23/16"
41/8"
45-125
LP-Gas
Capacity 2,100 CFH NH3
20-50
1584MN
Capacity Determined at Set Pressure of PSIG 20
1/4" F. NPT
AA1582MH
1584ML
Width
Height (max.)
45-125
215/16"
47/8"
AA1584MH
45-125
60
5,100 CFH NH3
189234
1586MN
3-30
20
11,000,000 BTU/hr. LPG
162802
25-50
30
12,000,000 BTU/hr. LPG
162801
45-125
60
14,000,000 BTU/hr. LPG
189126
20
7,000 CFH NH3
162141
30
7,700 CFH NH3
162413
Tee Handle 1586ML
LP-Gas 3/4" F. NPT
1586MH AA1586MW AA1586ML
3-25 20-50
NH3
31/2"
7"
AA1586MH
45-125
60
8,900 CFH NH3
189235
1588MN
3-30
20
11,000,000 BTU/hr. LPG
162804
25-50
30
12,000,000 BTU/hr. LPG
45-125
60
14,000,000 BTU/hr. LPG
1588ML
LP-Gas
1" F. NPT
1588MH
162803
High Pressure/High Temperature Pounds-to-Pounds Industrial/Commercial Designed to reduce LP-Gas container pressures to between 3 and 50 PSIG. Ideal for crop drying, heat treating, asphalt batch mixing and other large industrial and commercial load application utilizing high temperature LP-Gas or high temperature atmosphere under conditions up to 300°F. X1584MW
Part Number
Service
Adjustment Method
X1584MN X1584ML X1586MN X1586ML
Recommended Capacity Inlet & Delivery Determined at Outlet Pressure Range Set Pressure of Connection (PSIG) PSIG 1/2" F. NPT
LP Gas
Tee Handle 3/4" F. NPT
3-20
20
Capacity BTU/hr. Propane
Webb#
7,000,000
190688
25-50
30
7,500,000
190687
3-30
20
11,000,000
250279
25-50
30
12,000,000
250290
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REGULATORS & ACCESSORIES
5
Pigtails are available in a variety of connections, sizes and styles. Care should always be taken in selecting the proper pigtail for a particular application. 912JS20
Note: Engineered Controls International, Inc., recommends a new pigtail be installed with every new and replaced regulator. Part Number
Connections
912PS12 912PS20 912PS30
M. POL x M. POL
Approx. Length
Tube
Hex Short Nipple
Hex Long Nipple
Webb#
12"
188575
20"
162812
30"
912PS36
36"
162813
912PS48
48"
162814
912FS12
12"
912FS20
20"
912FS30
1/4" Inver ted Flare
x M. POL
912FS36
912PA36
--
162807
20"
162809
36"
188577
1/4"
PIG1665-48 186535
12"
162808
48"
PIG1669-48 186539
20" M. POL x M. POL
912PA48 912FA20
7/8"
1/4" M. NPT x M. POL
POL x 1/4"
162810
36"
PIG1660-36 186525 --
48" 1/4" Inver ted Flare
x M. POL
11/8"
20"
162811 162805
913PS05
5"
913PS12
12"
202603
913PS20
20"
188582
913PS30
M. POL x M. POL
913PS36
30"
48"
913JS05
1/4" M. NPT x M. POL
913LS12
1/2" M. NPT x M. POL
12"
POL x 1/2 MPT
20"
913LS20
PIG1680-30 186544
36"
913PS48
913KL12
186531
30"
48"
912PA20
PIG1664-30
PIG1665-12 186532
36"
912JS36
Webb#
162806
POL x 1/4" Inverted Flare 912JS12 912JS20
Alt. Marshall PIG#
3/8" M. POL 1/4" M. NPT x M. POL
3/8"
7/8"
--
188581
5" 222232 PIG1684-20 186547
12" 20"
187000
PIG1690-20 186549
Inlet Fittings These inlet fittings are available for assembly into either first stage or single stage regulators. All have 1/4� M. NPT connections and are machined from brass. Part Number
970
970AW
970AX
970HT
970AXS
970S
970
Description Hard nose POL with wrench nut.
Webb# 191818
970AX
Hard nose POL with wrench nut and excess flow.
187003
970AXS
Soft nose POL with wrench nut and excess flow.
246565
3199W
Heavy duty hard nose POL with wrench nut and excess flow.
186856
970AW
Soft nose POL with handwheel.
187002
970HT
Soft nose POL with handwheel and 60 DMS orifice.
243117
970S
Soft nose POL with wrench nut and 60 DMS orifice.
162771
The VICTOR Propane Equipment Catalog
REGULATORS & ACCESSORIES
Copper Pigtails
REGULATORS & ACCESSORIES
6
REGULATORS & ACCESSORIES Brackets RegO® Brackets are especially designed for use in installing RegO® Regulators in applications requiring the use of a bracket. Part Number
2503-19
2503-22
2302-31
Material
For Use With Regulator Model
Webb# 162798
2503-22
Cadmium Plated Steel
2302 Series/404B23
Aluminum
LV404 Series, 2503 Series, LV4403 Series
162797
2503-19
2302-31
162796
Tee Check Manifolds For use in systems that require uninterrupted gas service during cylinder exchange. Especially for summer cottages, mobile homes and single appliance loads. 1450R 1350R
Part Number
Inlet Connections
Outlet Connection
Webb#
Marshall PIG#s
Webb#
1350R
F. POL
M. POL
162820
PIG1000A
186519
1450R
1/4" Inver ted Flare
1/4" M. NPT
162821
PIG1702A
186552
Multiple Cylinder Manifolds Use with suitable pigtails to connect multiple cylinders together. Ideal for loads that require more than one cylinder to be in service at a time. 1450E 1350E
Part Number
Inlet Connections
Outlet Connection
Webb#
Marshall PIG#s
Webb#
1350E
F. POL
M. POL
162819
PIG1701B
186551
1450E
1/4" Inver ted Flare
1/4" M. NPT
162822
PIG1000B
186520
--
PIG1702B
186553
--
11/8" Hex L/Check
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REGULATORS
7
Based on years of operating experience, the new Model 046 family of field regulators combines simplicity of design, rugged construction, exceptional performance and operational safety to provide a dependable, flexible and economical answer to poundsto-pounds pressure regulation applications. Typical applications for the Model 046 Field Regulators are: • Farm taps • Field regulator applications • High pressure industrial air or gases
Internal Relief Valve Regulator 046-2 This regulator has relief protection to prevent damage to internal parts and the downstream system. The relief valve is activated by internal over-pressurization of the outlet chamber above the set outlet pressure of the regulator. Integral IRV stops reduce relief pressure build-up for added safety. Body: Ductile Iron Vent: 1” NPT for piping remote
046-2
PART NUMBER SPRING COLOR OUTLET PRESSURE RANGE 04600-021-00 Yellow 3 – 10 psig 04600-021-01
Aluminum
8 – 20 psig
04600-021-02
White
15 – 52 psig
04600-021-05
Green
10 – 95 psig
04600-021-03
Tan
50 – 125 psig
Capacity in SCFH of natural gas (0.6 Specific Gravity, 14.65 psia, 60°F)
046-2 Series Chart Yellow Spring (04600-021-00) Outlet Pressure 3-10 psi @ 75 psi Inlet Pressure Yellow Spring (04600-021-00) Outlet Pressure 3-10 psi @ 75 psi Inlet Pressure
Propane (S.P.1.53) 1350 BTU Ppropane/Air Mix (S.P.1.20) Natural Gas (S.P. 0.6) Capacity (scfh) Capacity (scfh) Capacity (scfh) Outlet Orifice Orifice Orifice Pressure Body psi Size 1/8" 3/16" 1/4" 5/16" 3/8" 1/2" 1/8" 3/16" 1/4" 5/16" 3/8" 1/2" 1/8" 3/16" 1/4" 5/16" 3/8" 1/2" 3/4" 1190 2213 2775 3150 3375 4013 750 1394 1748 1985 2126 2528 845 1571 1970 2237 2396 2849 5
10
1190 2213 3975 6150 6375 7123 750 1394 2504 3875 4016 4487 845
1571 2822 4367 4526 5057
11/4" 1190 2213 3975 6375 8100 7030 750 1394 2504 4016 5103 4429 845 3/4" 1190 2213 3638 4258 4453 6435 750 1394 2292 2683 2805 4054 845
1"
1571 2822 4526 5751 4991
1"
1571 2583 3023 3162 4569
1190 2213 3900 5395 5775 5920 750 1394 2457 3399 3638 3730 845
1571 2769 3830 4100 4203
11/4" 1190 2213 3900 5395 5940 6660 750 1394 2457 3399 3742 4196 845
1571 2769 3830 4217 4729
The VICTOR Propane Equipment Catalog
REGULATORS
Model 046 First Stage Field Regulators
8
REGULATORS
REGULATORS
Model 043 Second Stage Service Regulators A general purpose service regulator for smaller loads Simple spring operation, rugged construction and modern design make the 043 an ideal combination of economy, dependability and outstanding performance. Although mainly used for natural gas, it performs equally well on air, dry CO2, nitrogen, propane, LPG and others. Use the versatile 043 on industrial and commercial applications as well as in: • Distribution systems • Standard house services • 2 psi system services • Pilot lights for larger combustion systems • Burners, boilers, furnaces, ovens, unit heaters, gas engines, etc. Part Number
Description
Pipe Sizes
Body
Webb#
3/4"
Angle
181922
3/4"
Straight Through
181920
1"
Angle
181923
1"
Straight Through
181921
043-92-12 043-182-12
Regulator with Internal Relief Valve Type Diaphragm
043-92-16 043-182-16
Maximum Inlet Pressure
Spring Ranges Springs Outlet Pressure Ranges
Color
Part#
31/2" to 61/2" w.c.
Red
143-08-021-00
5" to 81/2" w.c.
Blue
143-08-021-01
6" to 14" w.c.
Green
143-08-021-02
12" to 28" w.c.
Orange 143-08-021-03
1 psi to 2 psi
Black
Orifice Size
143-08-021-04
Maximum Inlet Pressure For a Full Capacity Relief
Capacities for Other Gases For capacities ( in SCFH) of other gases, multiply the capacity values by a correction factor from the table below:
A
B
1/8"
26 psig
73 psig
3/16"
9 psig
24 psig
Other Gases
Specific Gravity
Correction Factor
1/4"
5 psig
14 psig
Propane
1.53
0.63
5/16"
4 psig
11 psig
3/8"
3 psig
8 psig
A. outlet pressure will not exceed 1 psi. B. outlet pressure will not exceed 2 psi. Note: Above data based on 5” – 81/2” w.c. (blue) spring
Capacity* in SCFH natural gas (0.6 Specific gravity – 14.65 psia – 60°F.) (The inlet pressure for each capacity value shown in bold face in the tables below is the Maximum Inlet Pressure for the applicable combination of Orifice Size, Pipe Size and Spring) Outlet Pressure Range 1 psi to 2 psi (Black Spring)
Outlet Pressure Range 31/2" w.c. to 28" w.c. (Red, Blue, Green or Orange Spring) Pipe Size (Inlet & Outlet) NPT.
Inlet Pressure psi 1/2
3/4" x 3/4"
1 2 3 5 10 20 40 60 80 100 125 1/2
1" x 1"
1 2 3 5 10 20 40 60 80 100 125
Orifice Size 3/8"
100 200 300 500 800 800
150 200 300 500 900 900
5/16"
180 250 400 750 800 800
150 190 250 400 850 900 900
1/4"
210 270 500 600 700 800
130 160 210 350 600 700 800 900
3/16"
300 450 650 700 800
90 130 160 230 300 450 650 800 900
1/8"
Pipe Size (Inlet & Outlet) NPT.
Orifice Size 3/8"
5/16"
1/4"
3/16"
1/8"
125 250 400 500
3/4" x 3/4"
3 5 10 20 40 60 80 100 125
125 250 400 500 700
100 200 250 450 650 900
60 125 200 400 650 900 900
50 80 125 250 400 650 750 900 900
125 250 400 750
1" x 1"
3 5 10 20 40 60 80 100 125
125 250 400 750 1000
100 200 250 500 900 1000
60 125 200 400 900 900 1000
50 80 125 250 400 650 900 1000 1000
250 450 650 700 700 800 800 70 90 120 140 160 250 450 700 800 800 900 900
Inlet Pressure psi
* Capacities are based on the following maximum variations in outlet pressure Red & Blue Springs 1” w.c. droop (-1” w.c.) to 2” w.c. boost (+2” w.c.) Green Spring 2” w.c.droop Orange Spring 3” w.c. droop Black Spring 10% droop
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
9
REGULATORS
The 143-80 is designed and built for domestic gas service, as well as for commercial and industrial applications; burners, furnaces, ovens, heaters, gas engines, etc. it can also be used for air, LPG, nitrogen, dry CO2 and other gases. Simple, rugged construction means dependability. Yet, it provides precise pressure control over an amazing range of pressure and load conditions. It is simple to install and adjust. The union nut connection makes it easy to locate the regulator in the best installed position, and servicing is easy and convenient. Part Number 143-80-212 143-80-216 143-80-220
Pipe Sizes Inlet x Outlet NPT 3/4" x 3/4" 3/4" x 1"* 3/4" x 11/4"*
1" x 1"
Description Regulator with Internal Relief Valve (IRV)
Spring Ranges Outlet Pressure Ranges
1" Body 11/4" Body
Webb# 181913 181909 188875
Maximum Inlet Pressures Spring Part Number
Spring Color
Orifice Sizes
5/8"
1/2"
3/8"
5/16"
1/4"
3/16"
1/8"
Max Inlet Pressure
10 psi
20 psi
40 psi
40 psi
60 psi
125 psi
125 psi
31/2" to 61/2" w.c.
Red
143-62-021-15
5" to 81/2" w.c.
Blue
143-62-021-16
6" to 14" w.c.
Green
143-62-021-17
Capacities for Other Gases
143-62-021-18
For capacities ( in SCFH) of other gases, multiply the capacity values by a correction factor from the table below:
12" w.c. to 1 psi
Orange
1" x 11/4"*
1/2 psi to 2 psi
Black & White
143-62-021-22
11/4" x 11/4"
1/2 psi to 3 psi
Cadmium
173-62-021-02
2 psi to 6 psi
Black*
139-16-021-01
* Special Order
Size 3/4" Body
* Good for use in 143 802HP Series only
Other Gases
Specific Gravity
Correction Factor
Propane
1.53
0.63
Models 143-80-2HP, 143-80-2 Capacity in SCFH natural gas (0.6 specific gravity – 14-85 psia – 60°F.) Pipe Size (inches)
Inlet Pressure (psig)
1/8"
1/2
1 2 3 5 3/4" x 3/4"
71/2 10 20 40 60 80 125
250 310 370 530 860 1200 1500 1800
1/2
1 2 3 5 I" x 1"
71/2 10 20 40 60 80 125
250 310 370 530 860 1200 1540 2100
1/2
1 2 3 5 11/4" x 11/4"
The VICTOR Propane Equipment Catalog
71/2 10 20 40 60 80 125
250 310 370 630 860 1200 1550 2250
Orifice Size (inches) 1/4" 5/16" 3/8" 1/2" 340 450 480 500 510 530 560 570 580 420 600 620 630 650 560 700 720 730 770 700 840 860 880 900 830 950 970 1000 1020 1200 1220 1240 1250 1270 1570 1330 1340 1450 1660 1520 1710 1900 350 460 480 550 600 530 700 840 880 420 650 870 1000 920 580 890 1120 1160 950 700 1140 1340 1270 1140 840 1360 1500 1330 1200 1230 2000 1600 1480 1400 1700 2000 1640 1900 1900 2000 2000 2100 350 460 480 550 680 530 700 840 1020 420 650 870 1030 1200 560 890 1180 1350 1490 700 1140 1500 1610 1580 840 1360 1700 1710 1800 1230 1600 1800 1900 1900 1800 2200 1900 2000 2100 2400 2200 2400 3/16"
5/8" 510 530 600 670 790 900 1020
520 650 780 810 970 1060 1180
520 760 1030 1050 1060 1060 1180
REGULATORS
Model 143-80 Second Stage Service Regulators
10 REGULATORS REGULATORS
Model 243 Second Stage Service Regulators These large capacity service regulators are designed and built for commercial, industrial and gas distribution work. They are right at home in such places as factories and foundries, district regulator stations, commercial laundries and laundromats, motelshotels and apartments, bakeries, restaurants, schools, churches and hospitals. The versatile 243 is used for all kinds of gas fueled equipment. . .boilers, burners, furnaces, ovens, heaters, kilns, engines, air conditioners, etc. Remarkable field versatility results from the union connection between the fully interchangeable bodies and diaphragm-case assemblies. They are easy to install, adjust, inspect and service in all kinds of piping arrangements. While used primarily for natural gas services, Model 243 regulators perform equally well on LPG vapor, air, dry CO2, nitrogen and other inert gas applications.
Basic Models Part Number
Description
243-12-224 243-12-232 243-8-220
Temperature Limit
Sizes
Webb#
11/2" Body 2" Body
Regulator with Internal Relief Valve (IRV)
181916 -20 F to 150 F
11/4" Body
243-8-224 243-8HP2-2
181915 181917
11/2" Body
181918
2" Body
247442
High Pressure Regulator
Outlet Pressure Ranges and Springs
Capacities for Other Gases
Outlet Pressure Range Spring Color
243-12
243-8
Spring Part # 143-82-021-00
Red-Black
--
31/2" to 61/2" w.c.
Blue-Black
--
5" to 81/2" w.c.
143-82-021-01
Green-Black
--
6" to 14" w.c.
143-82-021-02
Red
31/2" to 61/2" w.c.
--
143-16-021-03
Blue
5" to 81/2" w.c.
--
143-16-021-04 143-16-021-05
Green
6" to 14" w.c.
12" to 28" w.c.
Orange-Black
10" to 18" w.c.
--
143-16-021-11
Orange
12" to 28" w.c.
1 to 2 psi
143-16-021-06
Black
1 to 2 psi
2 to 41/4 psi*
143-16-021-07
Cadmium
11/2 to 3 psi
3 to 61/2 psi*
143-16-021-08
Cadmium
--
White
--
For capacities ( in SCFH) of other gases, multiply the capacity values by a correction factor from the table below: Other Gases
Specific Gravity
Correction Factor
Propane
1.53
0.63
143-16-021-08 6 to10 psi*
143-16-021-13
* Good for use in 243 8HP Series only
Maximum Inlet Pressure, psig Orifice Size and Angle 11/4"
11/4"*
1"
1"*
3/4"
3/4"
1/2"
3/8"
1/4"
.207"
30
10
30
10
30
10
10
10
10
10
11/4", 243-12
15
25
25
40
--
60
100
125
125
--
11/2", 243-12
15
25
25
40
--
60
100
125
125
--
2", 243-12
15
25
25
40
40
60
100
125
125
--
Regulator Model and Size
11/4", 243-8
--
--
--
--
--
40
80
100
125
125
11/2", 243-8
--
--
25
--
--
40
80
100
125
125
2", 243-8
--
--
25
--
40
40
80
100
125
--
11/4", 243-8HP
--
--
--
--
--
40
80
100
125
--
11/2", 243-8HP
--
--
25
--
--
40
80
100
125
--
2", 243-8HP
--
--
25
--
--
40
80
100
125
--
*External Control Regulator Only
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
11
REGULATORS Internal Relief Valves
The 243 is available with an internal relief valve (IRV). It’s a built-in safety device for providing a limited level of over-pressure protection. Like any relief valve, an IRV must be carefully sized. Internal relief valves are not available in the high pressure Model 243-8HP.
Model 243 Capacity Tables 2” Models 243-12-2 in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F Orifice Size and Valve Angle
Orifice Size and Valve Angle Outlet Pressure and Spring
Set Point 11" w.c. 2" w.c. Droop Green Spring 6" to 14" w.c. 143-16-021-05
Inlet Pressure psi
11/4" 30
1"
3/4"
30
3/8"
10
10
Outlet Pressure and Spring
10
Inlet Pressure psi
11/4"
1"
3/4"
3/8"
30
30
10
10
10
2
3350
3000
1900
1000
500
1/4"
1
3400
3000
1950
750
400
2
5600
4700
3400
1200
600
5
6600
5900
3900
1600
1000
10
11000
10000
6500
2800
1450
15
13000
5
10500
9000
6900
2100
1000
10
13000
13000
9200
3200
1600
15
14000
25
14000
10500
4000
1800
15000
12000
5300
2400
14500
7500
3200
40 60
15500
80 100
2
6500
5000
4000
1700 2400
40
14000
7500
3400
60
15500
10000
4400
12000
5600
5600
100
12000
7000
7000
125
12000
8000
12000
8000
5
1900
900
1300
500
6000
2200
1000
10
9000
8500
8000
3000
1400
15
12000
11000
10000
4000
1800
25
13500
13500
11500
5500
2400
15000
3800 5300
12000
7500
60
8300 11000
4400
8000
13000
12000 15000
25
10000
5
40
Set Point 1 psi 0.2 psi Droop Black Spring 1 to 2 psi 143-16-021-07
80
12000
125
Set Point 1 psi 0.31 psi Droop Orange Spring 12" to 28" w.c. 143-16-021-06
1/4"
7400
Set Point 2 psi 0.6 psi Droop Cadmium Spring 11/2 to 3 psi 143-16-021-08
3300
10000
4500
80
13000
6000
100
14000
7000
125
14000 85000
8200
7400
4800
10
12500
11300
7800
3000
1400
15
15500
14500
10000
3800
1700
13500
5300
2400
40
25
18000
16500
7600
3400
60
16500
10000
4600
80
12000
5600
100
12000
7000
125
12000
8000
11/4” and 11/2” Models 243-12-2 in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F Outlet Pressure and Spring
Set Point 11" w.c. 2" w.c. Droop Green Spring 6" to 14" w.c. 143-16-021-05
Orifice Size & Angle Valve
Inlet Pressure psi 1
11/4" 30 2700
1" 30 2300
3/4"
1/2"
3/8"
1/4"
10 1900
10 1100
10 750
10 400
Outlet Pressure and Spring
Inlet Pressure psi 5
11/4" 30 6000
Orifice Size and Valve Angle 1" 1/2" 3/8" 3/4" 30 10 10 10 5300 4100 2700 1700
1/4"
10 900
2
4000
3500
2700
1900
1200
600
10
10000
9300
7100
4700
2900
5
6000
5600
4500
3500
2100
1000
15
13000 12000
8800
6200
3800
1700
10
8800
8200
6500
5500
2900
1400
14500 11000 8600
5200
2400
15
10000
9800
7700
6800
3800
1750
11500
9700
8100
5100
2400
40
11500 9700
7100
3200
60
12500 11500 9300
4400
80
12000 10500
5600
125
100
12500 11000
7000
125
11000
8000
25
The VICTOR Propane Equipment Catalog
Set Point 2 psi 0.6 psi. Droop Cadmium Spring 11/2 to 3 psi 143-16-021-08
25
1400
40
13500 11000 7100
3200
60
15000 13500 10000
4600
80
15000 12000
5600
100
16000 12000
7000
12000
8000
REGULATORS
243 Variations
REGULATORS
12 REGULATORS Model 243 Capacity Tables (cont)
11/2” and 2” Models 243-8-1 and 243-8-2 in SCFH of Natural Gas Outlet Pressure and Spring
Set Point 11" w.c. 2" w.c. Droop Green/Black Spring 6" to 14" w.c. 143-82-021-02
Inlet Pressure psi 1
1" 30 1650
Orifice Size & Angle Valve 3/4" 1/2" 3/8" 1/4" 10 10 10 10 1150 1000 650 300
0.207"
(0.6 Specific Gravity — 14.65 psia — 60°F)
10
Orifice Size and Valve Angle 1" 1/2" 3/8" 1/4" 3/4" 30 10 10 10 10 2100 1650 1200 850 450
Inlet Pressure psi 2
Outlet Pressure and Spring
2
2700
2000
1400
1000
450
350
5
4000
3200
2100
1300
850
5
4800
3800
2600
1750
900
600
10
6500
5200
3100
2200
1300
10
7000
5400
4200
2800
1300
900
15
8400
6500
4400
3000
1700
15
9000
7400
5500
3600
1700
1100
25
11000
8600
6500
4400
2400
25
11000
8800
7500
5100
2400
1500
11000 8600
11000 9600
7100
3200
2100
60
11000 9300
4400
80
11500 10500
5600
11000
40
100 125
Set Point 2 psi 0.2 psi. Droop Orange Spring 1 to 2 psi 143-16-021-06
40
6700
3200
60
10500 9000
4400
2900
80
11500 10500
5600
3700
100
11000
7000
7000
4500
125
8000
5600
8000
11/4” Models 243-8-1 and 243-8-2 in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) Outlet Pressure and Spring
Set Point 11" w.c. 2" w.c. Droop Green-Black Spring 6" to 14" w.c. 143-82-021-02
Inlet Pressure psi 1
Orifice Size & Angle Valve 3/4"
1/2"
3/8"
1/4"
10 1150
10 1000
10 650
10 300
Outlet Pressure and Spring
Orifice Size & Angle Valve
Inlet Pressure psi 2
3/4"
1/2"
3/8"
1/4"
10 1850
10 1150
10 850
10 450
2
1850
1350
1000
450
5
2100
1700
1350
750
5
2500
2200
1750
800
10
2700
2000
1950
1300
10
2900
2700
2450
1300
15
3700
3950
2600
1700
25
4250
4000
3300
2400
40
5300
4200
3800
3200
60
4850
4400
80
5850
5600 6000
100 125
Set Point 11" w.c. 0.2 psi Droop Orange Spring 1 to 2 psi 143-16-021-06
15
3150
3100
2050
1700
25
4150
3250
2850
2400
40
5300
3800
3600
3200
60
4600
4250
4400
4400
80
4650
5600
5600
5600
100
6000
7000
7000
125
8000
8000
Model 243-8HP in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) SPECIAL ORDER 11/4" Model 243-8HP
Outlet Pressure 143-16-021-08
Inlet Pressure psi 10
Set Point 5 psi 1 psi Droop Cadmium Spring 3 to 61/2 psi
11/2" Model 243-8HP
Orifice Size & Valve Angle 3/4"
1/2"
3/8"
1/4"
10
10
10
3300
2050 2000
2" Model 243-8HP
Orifice Size & Valve Angle
Orifice Size & Valve Angle
3/4"
1/2"
3/8"
1/4"
10
1" 10
3/4"
1/2"
3/8"
10
1" 30
10
10
10
10
10
10
1300
6000
5500
3200
2300
1/4"
10
1300
6000
5500
3200
2400
1300
15
3400
3100 2200
1700
8600
6500
4400
3200
1700
8600
6000
4400
3200
1700
25
4400
3650 3050
2400
12000
9300
6100
4800
2400 13000
8200
6100
4800
2400
40
5800
12000
3800 3200
3200
8500
6100
3200
8700
6100
3400
60
4400 4100
4400
10000
8700
4400
10000
8700
4600
80
4500 5300
5600
11000 10000 5600
11500
10000 5600
100
6000
7000
11000 7000
11000 7000
8000
8000
8000
125
12000
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REGULATORS
13
Maxitrol Company manufactures a complete line of gas appliance regulators for domestic, commercial, and industrial needs.
Balance Valve Design — 210D, E & G Main burner and pilot applications The balanced valve 210 Series are designed for use with intermediate pressure. The balancing diaphragm virtually eliminates inlet pressure effect, which makes them ideal for applications where supply pressure fluctuates. Part Number
210D, E & G
Pipe Sizes
Capacities to
210D
Inlet Pressures to
Outlet Pressures
10 psi (700 mbar)
1.0" to 42" w.c. (2.5 to 105 mbar)
6500 CFH 1", 11/4", 11/2", 2", 21/2", & 3"
210E
12000 CFH
210G
26000 CFH
Part Number 210D-1 210D-1010-114 210D-112 210D-36-24 210D412-20 210D412-24 210E-2 210E412-24 210E412-32
Body Sizes 1" 11/4" 11/2" 11/2" 11/4" 11/2" 2" 11/2" 2"
Qty. Per Case 4 4 4 4 4 4 2 2 2
Webb# 201676 201679 201678 199526 201617 201629 198116 201673 201674
Capacities for Spring Loaded Models — Cubic feet per hour (0.54 sp gr gas) Part Number
210D 1"
210D 11/4"
Inlet Pressure 8.0 w.c. 0.5 psi 0.75 psi 1.0 psi 1.5 psi 2.0 psi 3.0 psi 5.0 psi 7.5 psi 10.0 psi 8.0 w.c. 0.5 psi 0.75 psi 1.0 psi 1.5 psi 2.0 psi 3.0 psi 5.0 psi 7.5 psi 10.0 psi
Outlet Pressure Incles w.c. 4 6 12 1,900 1,300 3,100 2,700 4,000 3,800 2,900 4,000 4,500 3,900 4,000 4,500 4,800 4,000 4,500 4,800 4,000 4,500 4,800 4,000 4,500 4,800 4,000 4,500 4,800 4,000 4,500 4,800 2,400 1,700 3,400 2,700 4,700 3,800 3,700 5,000 4,500 4,900 5,000 4,500 6,000 5,000 4,500 6,000 5,000 4,500 6,000 5,000 4,500 6,000 5,000 4,500 6,000 5,000 4,500 6,000
The VICTOR Propane Equipment Catalog
Part Number
210D 11/2"
210E 11/2"
Inlet Pressure 8.0 w.c. 0.5 psi 0.75 psi 1.0 psi 1.5 psi 2.0 psi 3.0 psi 5.0 psi 7.5 psi 10.0 psi 8.0" w.c. 0.5 psi 0.75 psi 1.0 psi 1.5 psi 2.0 psi 3.0 psi 5.0 psi 7.5 psi 10.0 psi
Outlet Pressure Incles w.c. 4 6 12 2,500 1,800 4,000 3,600 5,000 5,000 3,800 5,000 5,000 5,100 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 2,500 1,800 4,000 3,600 5,000 5,000 3,800 5,000 5,000 5,100 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000 5,000 5,000 6,000
Part Number
210E 2"
Inlet Pressure 8.0" w.c. 0.5 psi 0.75 psi 1.0 psi 1.5 psi 2.0 psi 3.0 psi 5.0 psi 7.5 psi 10.0 psi
Outlet Pressure Incles w.c. 4 6 12 4,200 2,950 6,650 5,950 8,650 8,150 6,300 10,000 9,850 8,400 10,000 10,000 11,500 10,000 10,000 12,000 10,000 10,000 12,000 10,000 10,000 12,000 10,000 10,000 12,000 10,000 10,000 12,000
REGULATORS
Gas Appliance Pressure Regulators
REGULATORS
14 REGULATORS Straight-Thru-Flow-Design RV52, RV53, RV61, RV81, RV91, RV111, RV131 1/2”, 3/4”, 11/4”, 11/2”, 2”, 21/2”, 3”, & 4” Main burner only The straight-thru-flow RV Series, size for size, has the highest pressure drop capacity of any regulator design available. They are best used when supply pressure is low enough to cause concern about capacity.
RV52 & RV 53
Gases: Natural, manufactured, mixed, liquified petroleum, or LP gas-air mixture
RV61
Features: • Greater accuracy — higher pressure drop capacity • Outlet pressure available to 42” w.c. • Available in full range of pipe sizes from 1/2” to 4” • All models tapped with NPT vent bosses • A.G.A. Rated (except RV131) — 1/2 psi (35 mbar)
RV81 & RV91
RV111
Part Number
Pipe Sizes
Capacities to
RV52
1/2" & 3/4"
900 CFH
RV53
3/4" & 1"
1300 CFH
RV61
1" & 11/4"
2500 CFH
11/4", 11/2", 2" & 21/2"
4500 CFH
RV81 RV91
RV131
7500 CFH
RV111
21/2" & 3"
1 psi
RV131
4" Flanged
2 psi
Part Number RV52-12 RV52-34 RV53-1 RV53-34 RV61-1 RV61-114 RV81-114 RV91-2 RV91-212
Body Sizes 1/2" 3/4" 1" 3/4" 1" 11/4" 11/4" 2" 21/2"
Qty. Per Case 25 25 25 25 18 18 4 4 4
Inlet Pressures to
Outlet Pressures
1/2 psi (35 mbr)
1.0" to 12" w.c.
1 psi (70 mbr)
1.0" to 22" w.c.
2 psi (140 mbr)
3.0" to 42" w.c.
Webb# 108537 196920 118670 108742 185908 188934 196848 109623
Capacities and Pressure Drop
Spring Selection Chart
3
Capacities: expressed in CFH (m /h) — 0.64 sp gr gas
Part Number RV52 RV53 RV61 RV81 RV91 RV111 RV131
Pipe Sizes 1/2" x 1/2" 3/4" x 3/4" 3/4" x 3/4" 1" x 1" 1" x 1" 11/4" x 11/4" 11/4" x 11/4" 11/2" x 11/2" 2" x 2" 21/2" x 21/2" 21/2" x 21/2" 3" x 3"
A.G.A. Max 450 (12.7) 710 (20.1) 1100 (31.1) 2500 (70.8) 3275 (92.7) 7500 (212)
4" x 4"
--
Pressure Drop in incles w.c. (mbar) 0.3 0.5 262 338 (7.4) (9.5) 375 484 (10.6) (13.7) 675 848 (19.1) (24) 1350 1743 (38.2) (49.5) 2100 2711 (59.4) (76.7) 4750 6132 (134) (175) 8200 10586 (232) (300)
— inches w.c. (mbar) Part Number
A.G.A. Certified Springs
RV52 RV53 RV61 RV81
3 to 6 (7.5-15)
4 to 8 (10-20)
5 to 12 (12.5-30)
RV91 RV111 RV131
--
OTHER SPRINGS AVAILABLE
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REGULATORS
15
Features:
325-5ALX
Outlet Pressure Range (all models) Certified spring — 7-11 in w.c.
• CSA certified for up to 5-psi inlet pressure • Over-pressure protection device (OPD) to limit downstream pressure in case of regulator failure • Maxitrol OPD approved and tested with the regulator • Regulators or OPD’s can be ordered as separate items — or as a factory assembled unit • Self-aligning valve with lever action for dead end regulator lockup • Optional vent limiter eliminates the need to run vent piping to an outside area Benefits: • Meets new ANSI standard Z21-80 for line pressure regulators — for use on piping systems such as CSST or semi-rigid copper tubing up to 5-psi • OPD provides required downstream over-pressure protection for supply pressures in excess of 2-psi • Pounds to inches regulator provides precise control from pilot flows to full regulator capacity • Meets many utility specifications Part Number 325-3L-12 325-3L-38 325-5AL-1 325-5AL-12 325-5AL-34 325-7L-114 325-7L-112
Body Sizes 1/2" 3/8" 1" 1/2" 3/4" 11/4" 11/2"
Qty. Per Case 50 50 18 18 18 4 4
Webb# 252139 252138 252142 252140 252141 224151 224152
Attention: To comply with the ANSI Z21-80 Standard for Line Pressure Regulators, installations exceeding 2psi nominal require a tested and approved over-pressure protection device (OPD) for use with the regulator. (Overpressure protection is not required for supply pressures up to and including 2-psi.)
Capacities and Pressure Drop — 2-psi, regulator only Model Outlet Number Pressure (pipe size) Set Point 325-3L 7.0" w.c. (3/8", 1/2") 10.0" w.c. 325-5AL 7.0" w.c. (1/2") 10.0" w.c. 325-5AL 7.0" w.c. (3/4", 1") 10.0" w.c.
Vent Limiters MFR# WEBB# Automatic Vent Limiting Device MXT12A04 77527 MXT12A06 192793 MXT12A09 109780 MXT12A39 192794 Outdoor Vent Cap MXT13A15 246350
1/2 psi (34 mbar) 145 (4.1) 110 (3.1) 335 (9.5) 150 (7.0) 335 (9.5) 150 (7.0)
Operating Inlet Pressure 11/2 psi 3/4 psi 1 psi (103 (52 mbar) (89 mbar) mbar) 200 (5.7) 250 (7.1) 250 (7.1) 180 (5.1) 230 (6.5) 250 (7.1) 425 (12.0) 425 (12.0) 425 (12.0) 420 (11.9) 425 (12.0) 425 (12.0) 475 (13.5) 550 (15.6) 550 (15.6) 420 (11.9) 535 (15.1) 550 (15.6)
Max Capacity 2 psi Btu/hr (138 Total load of all mbar) appliances 250 (7.1) 250,000 250 (7.1) 425 (12.0) 425,000 425 (12.0) 550 (15.6) 550,000 550 (15.6)
OPD’s Part Number
Description
OPD47
3/8", 1/2" -- For use with 325-3LX
OPD48
1/2" -- For use with 325-3LX 1/2", 3/4" -- For use with 325-5ALX
OPD600
3/4", 1" -- For use with 325-5ALX
Webb#
2 lb. Pressure System Length of Runs: A = 100’ B = 15’ C = 10’ D = 25’ E = 20’ Allowable drop: 1 PSI up to reg. 3” w.c.-reg. to appliance
The VICTOR Propane Equipment Catalog
REGULATORS
325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
REGULATORS
16 REGULATORS Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48 Main burner and pilot applications Part Number Pipe Sizes 1/8" RV12 1/4" & 3/8" RV20 RV47 & CV47 3/8" & 1/2" 1/2" & 3/4" RV48
RV12
RV20
RV47 & CV47
Part Number RV20L-38 RV47CL-12 RV47CL-38 RV47L-12 RV47L-38 RV48CL-12 RV48CL-34 RV48L-12 RV48L-34
Body Sizes 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" 3/4" 1/2" 3/4"
Capacities to 25 CFH 65 CFH 125 CFH 250 CFH
Qty. Per Case 100 50 50 50 50 50 50 50 50
Inlet Pressures to 1/2 psi (35 mbar) 2 psi
Outlet Pressures
1.0" to 12" w.c.
1/2 psi (35 mbr)
Webb# 185902 185903 188932 197256 188933 185905 185904 185907 185906
Capacity Chart — expressed in Btu/h (cubic meters/h) — 0.64 sp gr gas RV48
Part Number RV12 RV20
Pipe Sizes 1/8" x 1/8" 1/4" x 1/4" 3/8" x 3/8"
Main Burner Range of Regulations 30,000 (.85) 65,000 (1.84)
RV47 RV47A
3/8" x 3/8" 1/2" x 1/2"
125,000 (3.5)
RV48
1/2" x 1/2" 3/4" x 3/4"
230,000 (6.5) 250,000 (7.1) 400,000 (11.3)
RV48C
Note: Minimum main burner regulation capacity for all models (except “N”) is 150 Btu/h
Accessories Vent Limiting Means Ball check permits free inhalation for fast regulator diaphragm response on opening cycle, but limits gas escapement to within ANSI standards should a diaphragm rupture. Vent Limiter 12A09
Part Number 12A04 12A06 12A09 12A39
Description Optional Automatic Vent Limiting Device for RV48, RV52, RV53, RV61 Optional Vent Limiting Orifice for RV48, RV52, RV53, RV61 Optional Automatic Vent Limiting Device for 325-3, 325-3L, 325-3LX, OPD48, OPD600, 325-3L47 (reg. only), 325-3L48 (reg. & OPD), 325-5AL48 (OPD only), 325-5AL600 (OPD only) Optional Automatic Vent Limiting Device for 325-5A, 325-5AL, 325-5ALX, 325-5AL48 (reg. only), 325-5AL600 (reg. only)
Webb# 77527 192793 109780 192794
Spring Selection Chart Model Number RV12L RV20L RV47L RV48 RV52 RV53 RV61 RV81 210D RV91 210E RV111 325-3 325-5A 325-7
Part Number R1210T-35* R2010-35* R4710-35* R4819036* R5210-36* R5310-36* R6110-36*
Outlet Pressure 2.8 to 3.5 2.8 to 5.2 2.8 to 5.2 3.0 to 6.0 3.0 to 6.0 3.0 to 6.0 3.0 to 6.0
RS110-36*
3.0 to 6.0
R9110-36*
3.0 to 6.0
R11110-36* R325C10-711 R325E10-711A R8110-412*
3.0 to 6.0 7.0 to 11 7.0 to 11 4.0 to 12
* Standard Spring
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REGULATORS
17
Low Pressure Two-Stage 254-00 The 254 two-stage automatic changeover regulator offers the convenience of changeover from empty to full gas cylinders, plus the additional efficiency of two-stage pressure regulation. The top portion of the changeover is a duel high pressure regulator, which reduces container pressure to approximately 10 to 15 PSIG and sends it to the second stage regulator, which completes the regulation process by reducing the 15 psig inlet pressure down to 11 inches of water column (0.4 PSIG) outlet pressure.
254-00
The 240-00 is an automatic changeover regulator that meets RVIA requirements for use on recreational vehicles and complies with revised UL 144 requirements (June 1998) and NFPA requirement.
290-00 The 290 series integral two-stage regulator is a high pressure regulator combined with a second stage regulator. The high pressure regulator reduces the full cylinder pressure within 10-13 PSIG range. The second stage then reduces this inlet pressure down to 11 inches of water column (0.4 PSIG) outlet pressure. The 290-00 is an integral, two-stage regulator that meets RVIA requirements for use on recreational vehicles and complies with revised UL 144 requirements (June 1998) and NFPA requirements.
Adjustable High Pressure 350-00 290-00
The Marshall adjustable high pressure single-stage regulators are designed for use with appliances, such as torches, camp stoves, fish cookers, etc. that require pounds per spare inch of pressure instead of WC inches. Marshall can meet or exceed most requirements on a specific outlet setting (0-15 PSIG), depending on the application.
High Pressure LP Gas Regulator and Service Tool 130#139
350-00
The Marshall high pressure single-stage regulators are designed for use in applications that require pounds per square inch of pressure instead of WC inches. The 13000 can be used to regulate air as well as LP gas. It can also be used as the first stage regulator of a two stage system. MFR# 254-00
DESCRIPTION Automatic Changeover Regulator
WEIGHT 1.35 lbs.
WEBB# 182636
290-00
Two-Stage Regulator, Twin Stage
1.09 lbs.
182656
350-00
1/4� FNPT Outlet
.56 lbs
130#139 Pre-set at 10 PSIG
.5 lbs
130#139
Regulator Covers 862-00 Regulator Cover for second Stage
Specifications MFR# 862-00
The VICTOR Propane Equipment Catalog
DESCRIPTION Regulator cover for secondstage
WEBB#
REGULATORS
LP Gas Regulators
18
CYLINDER & SERVICE VALVES
CYLINDER & SERVICE VALVES
Compact Cylinder Valves with Overfilling Prevention Devices The 907NFD Series Cylinder Valves are designed for use on DOT LP-Gas Cylinders up to 40 lbs. The outlet features a back check assembly — designed to prevent gas flow until a leak free connection is made with an inlet adapter. These valves comply with both the ANSI Z21.58 Standard for Outdoor Cooking appliances and the CAN/CGA-1.6 Standard for Container Connections which apply to new barbeque grill cylinders manufactured after October 1994. They also conform to requirements in the 1998 edition of NFPA 58.
907NFD Series Type 1 Valves
Service Connection Part Number
Dip Tube Length with Deflector
For use on DOT Cylinders up to:
907NFD3.0
3.0"
5 lbs.
907NFD4.0
4.0"
20 lbs.
907NFD4.8
4.8"
30 lbs.
907NFD6.5
6.5"
40 lbs.
Container Connection
Type
Accessories Fixed Liquid Pressure Level Vent Relief Valve Valve Style Setting
Description
ACME Dust Cap
Webb# 192112
3/4" M. NGT
Type 1
15/16" M. ACME and F. POL CGA 791
Slotted
375 PSIG
907-12 Included
192109 192110 192111
Heavy Duty Cylinder Valves for Vapor Withdrawal
9103D
This heavy duty cylinder valve is designed for vapor withdrawal of DOT cylinders up to 100 lbs. propane capacity. It is used in domestic hookups, with RV’s and as a heavy duty barbeque cylinder valve.
Part Number
Container Connection
Service Connection
3/4" M. NGT
F. POL (CGA 510)
9103COA 9103D10.6
Fixed Liquid Level Vent Valve Style
Dip Tube Length w/Deflector
None
None 10.6"
9103D11.6
Approximate Filling Rate Liquid Flow, GPM
Accessories
Pressure Relief Valve Setting
For use in Cylinders w/Propane Capacity up to:
10 PSIG
25 PSIG
50 PSIG
100 PSIG
POL Plug
Webb#
375 PSIG
100 lbs.
12.7
20.3
29.0
41.3
N970P
162726
Pressure Drop Across Valves
162725
11.6"
162727
Cylinder Valve for Liquid Withdrawal Equipped with excess flow valves and liquid withdrawal tubes, they are designed for liquid withdrawal of DOT cylinders up to 100 lbs. propane capacity. They are most often used with heavy BTU loads found in industrial uses.
Part Number
Container Connection
Service Connection
Fixed Liquid Level Vent Valve Style
Dip Tube Length w/Deflector
Liquid Withdrawal Tube Length
Webb#
9107K8A
3/4" M. NGT
CGA 555
Knurled
11.6"
44"
162728
9107K8A w/Dip Tube
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
19
CYLINDER & SERVICE VALVES or Fuel Line Applications
Designed especially for vapor withdrawal service on ASME and DOT containers or in fuel line applications. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity. Approximate Filling Rate Liquid Flow, GPM
9101R Part Number 9101R1
Bonnet Style
Container Connection
Service Connection
Fixed Liquid Level Vent Valve
Multibonnet
3/4" M. NGT
F. POL CGA 510
Yes
9101R11.7
No
Pressure Drop Across Valves 10 PSIG
25 PSIG
50 PSIG
100 PSIG
7.6
11.7
15.2
20.6
Webb# 186996 162724
Service Valve for DOT Fork Lift Containers Designed especially for vapor or liquid withdrawal service on DOT fork lift containers. Valves with 1.5 GPM closing flow are for use in small and medium size left truck applications, while those with 2.6 GPM closing flow are for large lift trucks and gantry crane type vehicles. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that cylinders capacity. The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture. 9101P5
9101P6
When installed for liquid withdrawal, the 9101P6 Series has provisions for attachment of a liquid withdrawal tube. The 9101P5 Series must be installed in containers that have provisions for a separate liquid withdrawal.
To insure proper functioning and maximum protection from integral excess flow valves, these service valves should be fully opened and backseated when in use. Closing Flow (LP-Gas)
Part Number
Container Connection
Service Connection
Liquid Withdrawal Connection
9101P5
Vapor 25 PSIG Inlet (SCFH)
100 PSIG Inlet (SCFH)
Liguid (GPM)
430
900
1.5
550
1050
2.6
430
900
1.5
550
1050
2.6
None 9101P5H
3/4" M. NGT
3/8" M. NPT
Approximate Filling Rate Liquid Flow, GPM
Accessories
Pressure Drop Across Valves
ACME Check Connectors
10 PSIG
25 PSIG
50 PSIG
100 PSIG
Male
5.0
7.6
10.7
14.9
1/4" NPT 9101P6H
The VICTOR Propane Equipment Catalog
Cap
7141F
7141M-40 or 7141FP
Webb# 162720
7141M
9101P6
Female
4.5
7.2
10.3
162721 186995
14.8 190685
CYLINDER & SERVICE VALVES
Service Valves for ASME and DOT Containers
20
MULTIVALVE ASSEMBLIES
MULTIVALVE ASSEMBLIES
ASME Multivalves ® for Vapor Withdrawal These Multivalves® are designed for use in single opening ASME containers equipped with a 21/2” M. NPT riser. They can be used with underground ASME containers up to 639 sq. ft. surface area, and above ground ASME containers up to 192 sq. ft. surface area. A separate opening is required for liquid withdrawal. The MultiBonnet® is standard on this valve. The MultiBonnet® allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop Across Valves Part Number
G8475RW
G8475RV
10 PSIG 42
25 PSIG
50 PSIG
72
100 PSIG
98
125
G8475RW
190680 Vapor Equalizing Connection
Part Number
Container Connection
Service Connection
FIlling Connection
Webb# 187104
UL Listed Closing Flow
Connection Size
Float Gauge Flange Opening
Fixed Liquid Level Vent Valve Style
Dip Tube Length
Pressure Relief Valve Setting
G8475RV 21/2" F. NPT
F. POL (CGA 510)
13/4" M. ACME
11/4" M. ACME
Fits 4200 CFH "JUNIOR" @ 100 PSIG Size
Knurled
30"
UL Listed Relief Valve Capacity
For Use in Cylinders w/Surface Area Up To:
2020 SCFM/air
83 sq. ft. Above Ground 276 sq. ft. Underground
3995 SCFM/air
192 sq. ft. Above Ground 639 sq. ft. Underground
250 PSIG
G8475RW
ASME Multivalves ® for Vapor Withdrawal These Multivalves® provide vapor withdrawal and filling of ASME containers. A separate pressure relief valve is required in addition to this valve. The MultiBonnet® is standard on this valve. MultiBonnet® allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop Across Valves Part Number
10 PSIG
25 PSIG
50 PSIG
100 PSIG
Webb#
8593AR16.0
42
72
98
125
162498
8593AR16.0
Vapor Equalizing Connection Part Number
Container Connection
8593AR16.0 11/2" M. NPT
Service Connection
FIlling Connection
Connection Size
UL Listed Closing Flow
Fixed Liquid Level Vent Valve Style
Dip Tube Length
For Use in Containers w/Surface Area Up To:
F. POL (CGA 510)
13/4" M. ACME
11/4" M. ACME
4200 CFH @ 100 PSIG
Knurled
16"
**
** Since these Multivalves® have not integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
21
MULTIVALVE ASSEMBLIES
These Multivalves® permit liquid withdrawal from DOT cylinders with up to 100 lbs. propane capacity. They eliminate unnecessary cylinder handling when servicing high volume loads and allow on-site filling into the vapor space without interrupting gas service. Approximate Filling Rate Liquid Flow, GPM Pressure Drop Across Valves
8555DL11.6
Part Number
10 PSIG
25 PSIG
50 PSIG
100 PSIG
Webb#
8555DL11.6
8
23
34
42
162734
Part Number
Container Connection
Service Connection
FIlling Connection
8555DL11.6
3/4" M.NGT
CGA 555
13/4" M. ACME
Fixed Liquid Level Vent Valve Style
Dip Tube Length w/Deflector
Liquid Withdrawal Tube Length
Knurled
11.6"
44"
Pressure For Use in Relief Cylinders Valve w/Propane Setting Capacity Up To: 375PSIG
Liquid Closing Flow (LP. Gas)
100 lbs.
1.7 GPM
DOT Multivalves ® for Vapor Withdrawal These Multivalves® permit vapor withdrawal from DOT cylinders with up to 200 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop Across Valves Part Number
10 PSIG
25 PSIG
50 PSIG
100 PSIG
8
23
34
42
Webb#
6555R11.6 6555R12.0 8555D10.6
162732
8555R10.6
162740
8555D11.6
162733
8555R11.6
162741
8555D11.6 Pressure Relief Valve Flow Capacity Part Number
Bonnet Style
6555R11.6
MultiBonnet
6555R12.0
MultiBonnet
8555D10.6
Standard
8555R10.6
MultiBonnet
8555D11.6
Standard
8555R11.6
MultiBonnet
Application ASME Containers
For Use In Dip Tube Containers with Length Size Up to: w/Deflector 25’ Surface area or 60 Gallons Water Capacity
Fixed Liquid Level Vent Valve Style Setting
12.0"
200 lbs. Propane 11.6"
The VICTOR Propane Equipment Catalog
Service FIlling Connection Connection
11.6"
10.6" DOT Containers
Container Connection
3/4" M.NGT
F. POL (CGA 510)
13/4" M. ACME
UL Listing
ASME
250 PSIG
793 SCFM,air
700 SCFM,air
375 PSIG
N/A
N/A
Knurled
MULTIVALVE ASSEMBLIES
DOT Multivalves ® for Liquid Withdrawal
MULTIVALVE ASSEMBLIES
22
MULTIVALVE ASSEMBLIES DOT and ASME Multivalves ® for Vapor Withdrawal These Multivalves® permit vapor withdrawal from ASME containers up to 50 sq. ft. surface area and DOT containers up to 420 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop Across Valves
Bonnet Style
6542A12.0
Standard
6542R12.0
MultiBonnet
6533A11.7
Standard
6533R11.7
MultiBonnet
6543A11.1
Standard
10 PSIG
25 PSIG
50 PSIG
100 PSIG
Webb#
6542A12.0/6542R12.0
23
32
46
28
186872/162737
6533A11.7/6533R11.7
11
16
23
28
6543A11.1/6543R11.1
6543A11.7
Part Number
Part Number
6543A11.7/6543R11.7
Container Application Connection ASME
23
32
46
Service FIlling Connection Connection
162729/162736 162730/162738
57
162731/162739
Fixed Liquid Level Vent Valve Style
Dip Tube Length with Deflector
Pressure Relief Xalve Setting
For Use in Cylinders w/Propane Capacity Up To:
For Use In Containers w/Surface Area Up To:
12.0"
250 PSIG
--
53 sq.ft.
375 PSIG
420 lbs. Propane
--
1" M.NGT
3/4" M. NGT
11.7" F. POL (CGA 510)
13/4" M. ACME
Knurled 11.1"
DOT 6543R11.1
MultiBonnet
6543A11.7
Standard
6543R11.7
MultiBonnet
1" M.NGT 11.7"
ASME Multivalves ® for Vapor Withdrawal These compact Multivalves® are especially suited for vapor withdrawal of ASME containers where compact groupings of components are necessary. Separate filler valves and pressure relief valves are required. MultiBonnet® allows quick and easy repair of bonnet. 7556R12.0
Vapor Equalizing Connection Part Number 7556R12.0
Container Connection 3/4" M. NGT
Service Connection UL Listed Connection Size Closing Flow F. POL (CGA 510)
11/4" M. ACME
4200 CFH @ 100 PSIG
Fixed Liquid Level Vent Dip Tube Valve Style Length Knurled
12"
For Use in Containers w/Surface Area Up To:
Webb#
*
162742
* Since these Multivalves®have not integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLDS
23
Designed specifically for use as a primary relief valve in ASME transports and delivery trucks with 2” and 3” NPT couplings.
A8434G
Flow Capacity SCFM/Air
Part Number
Start To Discharge Setting PSIG
A8434G
Container Connection
Overall Height (Approx.)
Height Above Coupling (Approx.)
UL ASME (At 120% of (At 120% of Set Set Pressure) Pressure)
2" M.NPT
91/16"
1/2"
3700
177/8"
3/4"
10210
Suitable for Tanks with Surface Area Up To:
Protective Cap (Included)
Webb#
3456
175 sq. ft.
A8434-11B
187081
9598
602 sq. ft.
A8436-11B
162575
250 A8436G
3" M.NPT
Fully Internal “Pop-Action” Pressure Relief Valves for Motor Fuel Containers 8543 Series relief valves are designed for use as a primary relief valve in larger ASME motor fuel containers such as on buses, trucks and construction equipment. 8544 Series relief valves are designed for use as a primary relief valve in smaller ASME and DOT motor fuel containers such as on tractors, lift trucks, cars and taxicabs. 8544T Flow Capacity SCFM/Air
Part Number
Container Type
Start To Discharge Setting PSIG
8544G
Container Connection M.NPT
Overall Height (Approx.)
Height Above Coupling (Approx.)
1"
Hex Wrenching Section
Accessories
UL ASME (At 120% of (At 120% of Set Set Protective Cap Pressure) Pressure) (Included)
Pipeway Adapter
Webb#
7544-11A
162757
15/16"
1020
939
7544-41
111/16"
1465
1400
7543-40C
7543-10
189192
15/16"
1282
1158
7544-41
7544-11A
189193
11/4"
111/16"
1990
1731
7543-40C
7543-10
1"
15/16"
1545
--
7544-41
7544-11A
250 8543G
11/4" ASME
8544T
1"
57/16"
7/8"
312 8543T 8544K
DOT/ASME
375
162758
Fully Internal “Pop-Action” Pressure Relief Valve for DOT Fork Lift Cylinders
8545AK w/Protective Cap
Designed specifically for use as a primary relief valve on forklift cylinders, the 8545AK reduces the possibility of improper functioning of the relief mechanism due to foreign material build up. All guides, springs, stem and adjusting components are located inside the cylinder — removed from the direct exposure of foreign materials and debris from the atmosphere. Accessories (Order Separately) Flow Capacity SCFM/Air
Part Number
Container Type
Start To Discharge Setting PSIG
8545AK
DOT
375
The VICTOR Propane Equipment Catalog
Deflectors
Container Connection M. NPT
(ECIIfi Rated at 480 PSIG)
Protective Cap
45 Elbow
90 Elbow
Webb#
3/4"
400
7545-40
7545-14A
7545-12
162759
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLD S
Fully Internal “Pop-Action” Pressure Relief Valves for Transport and Delivery Trucks
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLDS
24
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLDS Semi-Internal “Pop-Action” Pressure Relief Valve for ASME Containers Designed specifically for use as a primary relief valve on ASME containers such as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists containers systems on which these types of valves are mounted outside the hood without additional protection, if mounted near the hood and fitted with a protective cap.
75B3G
Flow Capacity SCFM/Air Start To Discharge Setting PSIG
Part Number
Container Connection M. NPT
Overall Height (Approx.)
Height Above Coupling (Approx.)
3/4"
83/16"
17/16"
7583G 8684G
250
8685G
UL ASME Suitable for (At 120% of (At 120% of Tanks with Set Set Surface Area Pressure) Pressure) Up To:
Wrench Hex Section 13/4"
1980
1806
80 sq. ft.
Protective Cap (Included)
Webb#
7583-40X
162747
1"
93/8"
19/16"
17/8"
2620
2565
113 sq. ft.
8684-40
162749
11/4"
111/16"
111/16"
23/8"
4385
4035
212 sq. ft.
7585-40X
162750
Semi-Internal “Pop-Action” Pressure Relief Valve for Large Storage Containers
7534-40
Designed specifically for use as a primary relief valve on large stationary storage containers, these low profile relief valves are generally mounted in half couplings. However, they are designed so that the inlet ports clear the bottom of a full 2” coupling. This assures that the relief valve should always be capable of maximum flow under emergency conditions.
7534-20
Flow Capacity SCFM/Air
7534G
3135-10
Part Number
Start To Discharge Setting PSIG
Container Connection
7534G
250
2" M.NPT
Accessories
UL ASME Suitable for (At 120% of (At 120% of Tanks with Set Set Surface Area Pipeway Pressure) Pressure) Up To: Protective Cap Adapter 11,675
10,422
708 sq. ft.
7534-40
7534-20
Webb# 162574
External “Pop-Action” Pressure Relief Valve for ASME Containers and Bulk Plant Installations Designed specifically for use as a primary relief valve on ASME above ground and underground containers, bulk plant installations and skid tanks. The 3131 Series may also be used as a primary or secondary relief valve on DOT cylinders, or as a hydrostatic relief valve.
3135
All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage.
AA3135
Accessories Flow Capacity SCFM/Air (a)
Part Number
Start To Discharge Setting PSIG
AA3126L030
30
Pipeaway Adapter
UL (At 120% of Set Pressure)
ASME (At 120% of Set Pressure
Suitable for Tanks with Surface Area Up To: (e)
(b)
--
--
AA3126L250
277 (c)
--
23 sq.ft. (f)
3131G
2060
1939
85 sq. ft.
3131.40 (g)
Container Connection M. NPT 1/2"
Overall Height (Approx) 23/8"
Wrench Hex Section 7/8"
Protective Cap
Part Number
Outlet Size
Weep Hole Deflector
Webb# 187092
7545-40
1/2" M. NPT
AA3126-10
187093 --
3/4"
37/16"
13/4"
61/32"
23/8"
AA3130UA250 3132G 3135G
250
11/4"
AA3135UA250 3133G
521/32"
211/16"
613/32"
2045
1838
249 sq. ft. (f)
AA3130-40P
4130
--
200 sq. ft.
3132.54 (g)
5770
--
300 sq. ft.
3135-54 (g)
3135-10 AA3135-10
6430
5080 (d)
1010 sq. ft. (f)
AA3135-40PR
11/2"
515/16"
31/8"
6080
--
320 sq. ft.
3133-40 (g)
21/2"
101/2"
41/8"
10390
613 sq.ft.
3149-40
9153
A3149G A3149MG
--
(b) Not UL or ASME rated. .059 sq. in. effective area. (c) Not UL or ASME rated. ECII®rated at 120% of set pressure. (d) Rated at 110% of set pressure.
--
(f) Per ANSI K61.1-1972. Appendix A (g) Cap supplied with chain. (h) Outlet 31/2-8N (F) thread, will accept 3” M. NPT pipe thread.
AA3131-10
162436 1" F. NPT
187095
--
162442 3133-11 2" F. NPT
162447 190683 162446
(h)
Included (j)
162572
--
--
187128
(j) Weep hole deflector is Part No. A3134-11B.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLDS
25
Designed especially for protection of piping and shut-off valves where there is a possibility of trapping liquid LP-Gas or anhydrous ammonia. They may be installed in pipelines and hoses located between shut-off valves or in the side of boss in RegO速 shut-off valves. Accessories
Part Number
Start To Discharge Setting PSIG
Valve Body Material
1/4"
SS8001G SS8002G SS8021G SS8022G
3127G
Stainless Steel 250
1/2"
Pipeaway Height (Approx.) 7/8"
1/4" 1/2"
13/8"
1/4" NPSM Thrds
189248 162494
11/8"
3129.10
162429
7/8"
--
162422
219/32"
11/8"
3129.10
186844
1/4"
131/32"
7/8"
1/2"
219/32"
11/8"
1/2"
219/32"
1/4"
131/32"
1/2"
3129P
11/16"
--
189249
3127H
Brass
--
7/8"
162420
3129G
300
Webb#
11/16"
--
131/32"
275
Adapter or Threads
3/8" NPT Thrds
1/4"
3129H
Wrench Hex Protective Cap Section (Included)
7/8"
3127G
3127P
7545-40
--
186843
3129.10
186846
3127J
1/4"
131/32"
7/8"
--
162423
3129J
1/2"
219/32"
11/8"
3129.10
162430
SS8001J SS8002J
1/4"
350 Stainless Steel
SS8021J
3127K 3129K
1/2"
375
3125L
Brass
SS8001L SS8002L SS8021L
3127U
Brass
3129U SS8001U SS8002U SS8021U SS8022U
The VICTOR Propane Equipment Catalog
Stainless Steel
7/8"
11/8"
19/16"
5/8"
Included
131/32"
7/8"
7545-40
219/32"
11/8"
3129-40P
1/4"
1/2"
7/8"
1/4"
--
219/32" 7/8"
1/4"
11/8"
193305
3/8" NPT Thrds
187116
--
162424
3129.10 -3129.10
7/8"
--
162426 186845 192876
162495
3/8" NPT Thrds
187117
--
162428
3129.10 --
7/8"
162431 162751
1/4" NPSM Thrds
11/16"
11/16"
13/8"
7545-40
187114
1/4" NPSM Thrds
--
7/8"
7/8"
1/2"
1/2"
11/16"
11/16"
131/32"
1/2"
7545-40
13/8"
1/4"
1/4"
450
--
219/32"
1/2"
SS8022L
11/16"
13/8"
1/2"
1/4"
Stainless Steel
--
7/8"
131/32"
1/2"
400
11/16"
1/4"
3127L 3129L
7/8"
1/4" 1/2"
SS8022J
SS8022G
Container Connection M. NPT
162432 162490 187115
1/4" NPSM Thrds
162496
3/8" NPT Thrds
189250
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLD S
External Hydrostatic Relief Valves
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLDS
26
PRESSURE RELIEF VALVES & RELIEF VALVE MANIFOLDS DuoPort ® Pressure Relief Valve Manifolds for Small Storage Containers Designed especially for use as a primary relief device on smaller stationary storage containers, with 2” NPT threaded couplings. These manifolds allow servicing or replacement of either of the two relief valves without evacuating the container or loss of service. The operating lever selectively closes off the entrance port to the relief valve being removed while the remaining valve provides protection for the container and its contents. The rating of each manifold is based on actual flow through the manifold and a single pressure relief valve, taking friction loss into account, it is not merely the rating of the relief valve alone.
A8542UA250
Relief Valve Included
Flow Capacity SCFM/Air
Part Number
Start To Discharge Setting PSIG
LP-Gas
NH3
Container Connection M. NPT
Quantity
Part Number
Inlet Connection M. NPT
AA8542UA250
250
No
Yes
2"
2
AA3135MUA250
11/4"
Application
Accessory Pipeaway Adapter
UL (At 120% of Set Pressure
Webb#
AA3135-10
5865 (1)
189245
Multiport ® Pressure Relief Valve Assemblies for Large Storage Containers Designed especially for use as a primary relief device on large stationary pressurized storage containers with flanged openings. These manifolds incorporate an additional relief valve, not included in the flow rating, allowing for servicing or replacement of any one of the relief valves without evacuating the container. The handwheel on the manifold selectively closes off the entrance port to the relief valve being removed while the remaining relief valves provide protection for the container and its contents. All manifold flow ratings are based on flow through the relief valves after one has been removed for service or replacement.
A8564G
Relief Valve Included
Part Number
Start To Discharge Setting PSIG
Application LP-Gas
NH3
Container Flange Connection
A8564G A8574G A8564AG
Quantity
3"-300# 250
Yes
Yes
A8574AG
4"-300# 3"-300#
Part Number
Inlet Connection M. NPT
Flow Capacity SCFM/Air Accessory Pipeaway Adapter
A3149MG 21/2"
4 A3149G
4"-300#
UL Rating
ASME Rating
27,750 (3)
N/A
Not Applicable
27,400
****
Webb# 162576 162577 251121 251122
**** Outlet 31 / 2-*N (F) thread, will accept 3” M. NPT pipe thread.
Flange Dimensions Manifold Sizes
Flange Size
Flange Drilling
Port Diameter
Flange Gasket
A8560
Modified 3" 300# (4" Port Dia.)
(8) 7/8" Bolt Holes on a 65/8" Bolt Circle Diameter Flat Faced.
4"
3" 7564-48
A8570 AA8570
4" ASA 300#
(8) 7/8" Bolt Holes on a 77/8" Bolt Circle Diameter 1/16" Raised Face.
4"
4" 7565-48
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
27
GLOBE & ANGLE VALVES
Specifically designed to assure positive shut-off and long, maintenance-free service life in liquid or vapor service on bulk storage containers, transports, bobtails, cylinder filling plants and plant piping. The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries.
TA7034
A7505AP A7513AP A7517FP A7517AP
Part Number
Webb#
TA7034P
187119
TA7034LP
189253
A7505AP
162539
A7506AP
162540
TA7505AP
187120
TA7506AP
187254
A7507AP A7508AP
162541 162542
TA7507AP
192877
A7509BP
162543
A7510BP
162544
TA7509BP
193216
TA7510BP A7511AP
162545
A7512AP
162546
Flow at 1 PSIG Pressure Drop (Cv) (GPM/Propane)***
Part Number Buna N Seat Discs
Teflon Seat Discs* Inlet & Outlet Connection
Globe
Angle
Globe
Angle
--
--
TA7034P
TA7034LP
1/2" F. NPT
TA7506AP
3/4" F. NPT
A7505AP
A7506AP
TA7505AP
A7507AP
A7508AP
TA7507AP
--
1" F. NPT
A7509BP
A7510BP
TA7509BP
TA7510BP
11/4" F. NPT
A7511AP
A7512AP
TA7511AP
TA7512AP
11/2" F. NPT
A7511FP
--
--
A7513AP
A7514AP
TA7513AP
A7513FP
A7514FP
TA7513FP
A7517AP
A7518AP
TA7517AP
TA7518AP
3" F. NPT
A7517FP
A7518FP
TA7517FP
--
3" Flange**
11/2" Flange** --
A7518FP
Port Diameter
Globe
Angle
10.00
14.8
12.0
17.7
1"
17.8
22.0
11/4"
36.5
54.0
43.0
55.5
46.0
--
3/4"
11/2"
2" F. NPT
2"
2" Flange**
31/8"
75.0
88.5
78.0
133.0
197.0
303.0
* Teflon seat discs on valves built to order. ** 300# ANSI R.F. Flange *** To obtain approximate flow at other than 1 PSIGpressure drop, multiply flow in chart by square root of pressure drop.
TA7511AP TA7512AP
Flange Dimensions
A7511FP A7513AP
162547
Valve Number
162548
7511FP
TA7513AP
190681
7513FP
A7513FP
188570
7514FP
A7514AP
A7514FP
162549
7517FP
TA7513FP
187124
7518FP
A7517AP
162550
A7518AP
162551
TA7517AP
187126
A7517FP
187041 162552
TA7517FP
189255
11/2" 2"
3"
Flange Drilling 7/8" Bolt Holes on a 41/2"
Bolt Circle Diameter 3/4" Bolt Holes on a 5"
Bolt Circle Diameter 7/8" Bolt Holes on a 65/8"
Bolt Circle Diameter
D
E
F
H
61/8"
13/16"
27/8"
3/4"
61/2"
7/8"
35/8"
13/16"
81/4"
11/8"
5"
11/16"
Reducing screwed flanges are available for reducing 11 / 2” flange or 1” or 11 / 2” pipe thread and 3”flange to 21 / 2” pipe thread. Order from your local piping supplier.
TA7518AP
A7518FP
Size
The VICTOR Propane Equipment Catalog
Accessories Hydrostatic Relief Valve
Vent Valve
SS8001U (#162490)
TSS3169 (#162450)
GLOBE & ANGLE VALVES
“V”–Ring Seal Globe and Angle Valves for Bulk Storage Containers, Transports, Bobtails and Plant Piping
GLOBE & ANGLE VALVES Quick-Acting Minimum Loss Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations
GLOBE & ANGLE VALVES
28
Designed to vastly reduce the amount of product vented when disconnecting bobtail trucks, dispensing systems and anhydrous ammonia nurse tanks. These valves provide instant, full-on-flow at the flip of a handle. Shut-off is instant and the handle looks for added protection. This “top of the line” hose-end valve is a fully contained unit that does not require additional filling adapters or connectors.
A7797
Part Number
Inlet Connection F. NPT
Outlet Connection (F. ACME)
Locking Handle
Flow at 1 PSIG (Cv) Pressure Drop (GPM/Propane)
Webb#
A7793
3/4"
13/4"
Yes
16.0
187049
A7797
1"
13/4"
Yes
16.0
162712
Quick-Acting Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations Designed especially for safe operator handling of LP-Gas in bobtail delivery truck, dispensing systems and anhydrous ammonia nurse tank service. These valves provide instant, full-on flow at the flip of the handle and provide instant positive shut-off with a handle lock for added protection. A7707L
Accessories Filling Connectors Extended
Part Number
Body Design
A7707L
Globe
A7708L
Angle
Inlet & Outlet Connection (F. NPT) 1"
Locking Handle Yes
Flow at 1 PSIG (Cv) Pressure Drop (GPM/Propane)
Steel
18.0
Compact
Brass
Steel
Webb# 187048
A7575L4 3175A (#162711) (#162688) A3175A 162562
22.0
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant Piping Designed to assure positive shut-off and long maintenance-free service life in liquid or vapor service. Ideally suited for use on cylinder charging manifolds, truck filling hoses, bulk storage containers and plant piping. A7704P
A7706P
The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries. Part Number
Body Design
7704P
Globe
Inlet & Outlet Connection (F. NPT)
Flow at 1 PSIG (Cv) Pressure Drop (GPM/Propane)
Accessories Hydrostatic Relief Valve
Vent Valve
7.3
7704LP
Angle
A7704P
Globe
A7704LP
Angle
12.3
7705P
Globe
11.5
1/2"
Webb# 162557
12.3
190689
7.3
162558 SS8001J or SS8001L
TSS3169
162559 163076
7706P
Angle
17.7
163077
A7705P
Globe
11.5
162560
A7706P
Angle
17.7
162561
3/4"
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
29
GLOBE & ANGLE VALVES
Designed especially for liquid transfer of LP-Gas from consumer bulk storage containers when used with a Chek-Lok® or equipped with an integral excess flow valve. May also be used for vapor LP-Gas service. In NH3 applicator tanks they may be used as a vapor bleeder valve or as a liquid withdrawal valve when installed in a coupling with a dip pipe.
7550P
These liquid transfer valves are equipped with an integral excess flow valve for liquid transfer directly from the tank fitting, or without an integral excess flow for LPGas transfer through a Check-Lok®. When equipped with an integral excess flow valve (7550PX), the valve should be mounted in a forged steel 3000 lb. half coupling. When mounted in a 11/4” x 3/4” NPT reducing coupling, the 3/4” female thread in this coupling must be full length — equivalent to a forged steel 3000 lb. half coupling.
The excess flow valve will not function properly if these specifications are not met.
Part Number
Inlet Outlet Connection Connection Integral M. NPT (F. NPT) Excess Flow
7550P
Flow at 1 PSIG (Cv) Pressure Drop (GPM/Propane)
No
A7550P
13.3
Accessories Hydrostatic Relief Valve
Vent Valve
Webb#
3127U
3165
162760
SS8001J
TSS3169
162474
3127U
3165
162475
SS8001J
TSS3169
162476
3127U
3165
186911
--
3/4"
3/4"
7550PX
Excess Flow Approximate Closing Flow (GPM/Propane)
A7550PX 1/2"
7551P
Yes
--
16.0
No
8.9
--
Quick-Acting Valves for Cylinder Charging Hoses Designed primarily for use on cylinder charging hoses to provide fast, convenient shutoff and fast opening.
7901TA
These valves must be installed so that flow through the valve is in the opposite direction to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve, even more important, helps prevent the valve from being forced open by high pump pressure. Part Number
Inlet Outlet Connection Connection M. NPT (F. NPT)
A7553A
1/4"
1/4"
7901TA
3/8"
3/8" 1/4"
7901TB 7901TC 7085T
The VICTOR Propane Equipment Catalog
1/2"
1/2"
Body Material
Flow at 1 PSIG (Cv) Pressure Drop (GPM/Propane)
Ductile Iron
Webb# 189220 162487
Brass
1.95
162488 162489
GLOBE & ANGLE VALVES
Flange Seal Liquid Transfer Angle Valves for Bulk Storage Containers
GLOBE & ANGLE VALVES
30
GLOBE & ANGLE VALVES Quick-Acting Valves for Crop Driers and Charging Manifold Hoses 7554S Series valves provide instant shut-off and fast opening control on LP-Gas crop driers. They are ideal for charging manifold hoses, stationary fuel transfer hoses and other applications requiring quick, positive shut-off. They are not for use with delivery truck hoses because the handle could snag on the ground and open the valve as the hose is needed back to the truck
7554S
7554L Series valves feature a locking handle device to help prevent accidental opening of the valve. It is ideal for all the same applications as the 7554S Series and may be used on delivery trucks as it incorporates the locking handle design. Both valve series must be installed so that flow through the valve is opposite to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve and prevents the valve from being opened by high pump pressures. Part Number 7554SAV
Inlet & Oulet Connection (F. NPT)
Locking Handle No
1/2"
7554LAV 7554SV
Flow at 1 PSIG (Cv) Pressure Drop (GPM/Propane)
No
3/4"
7554LV
186921
7.3
Yes
186920 162555
11.5
Yes
Webb#
162553
Multipurpose Valves for Liquid Withdrawal of LP-Gas and NH3 Containers Designed especially for use as a high capacity liquid withdrawal valve on LP-Gas and anhydrous ammonia containers.
A8017DB
The A8017DH is equipped with a soft seated automatic differential back pressure check valve in the seat disc assembly. This allows any pressure build up in the liquid transfer line in excess of 10-15 psig above the container pressure to flow back into the container. The transfer hose is protected against excessive liquid or vapor pressure entrapment, which adds materially to the useful life of flexible hose. In addition to increasing hose service life, the equalizing valve adds substantially to the operating safety of liquid transfer systems. Accessories Part Number A8017DH A8017DP
Inlet Outlet Connection Connection M. NPT (F. NPT)
11/4"
Excess Flow Approximate Closing Flow (GPM/Propane)
Hydrostatic Relief Valve
49
Not Required
55
SS8001J
1"
Vent Valve
Webb#
TSS3169
187075 162493
Multipurpose Valve for Filling and Liquid Transfer of NH3 Containers Designed primarily for use as a combination filler and liquid withdrawal valve on threeopening applicator tanks or on nurse tanks.
This valve incorporates an integral excess flow valve. When product is required, the valve must be completely open and backseated to allow the excess flow valve to function properly.
A8018DP
Part Number A8018DP
Inlet Outlet Connection Connection M. NPT (F. NPT)
11/4"
1"
Accessories
Filling Connection (M. ACME)
Filling Capacity at 20 PSIG Pressure Drop GPM/NH3
Excess Flow Approximate Closing Flow (GPM/NH3)
Hydrostatic Relief Valve
Vent Valve
Webb#
13/4"
74
50
SS8001J
TSS3169
187076
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
BALL VALVES
31
Model T-100 – System-5® – I.P.S
Models T-204 – System 2®
For use on LP Gas, flammable liquids, natural and mfg. gas, air, N2, inert gases, including helium, CO2 • 1/4” – 2” • Operable from -40°F to 300°F • UL listed
The new Jomar System-2 FIP to Flare, Flare to Flare and MIP to Flare valves are new products with vision. Equipped with all the features of the Blue-Cap®. • Raised wrench flats for installation ease. • It can be used in temperatures from -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The T-handle can be reversed into a locked position, by turning the handle to the off position, removing the tamper proof alien screw and reversing the handle 180° into the slot. • Each valve is shipped with plastic thread protectors to prevent leak causing nicks. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • AGA and CGA listed 0.5, 2 lb, 5 lb, System
Model S-100 – System-3® – C x C MFR# DESC. Model T-100 Series JOM100-701 1/4” FEM JOM100-702 3/8” FEM JOM100-703 1/2” IPS JOM100-704 3/4” IPS JOM100-705 1” IPS JOM100-706 11/4” IPS JOM100-707 11/2” IPS JOM100-708 2” IPS JOM100-709 21/2” IPS JOM100-710 3” IPS Model S-100 Series JOM100-803 1/2” C x C JOM100-804 3/4” C x C JOM100-805 1” C x C JOM100-806 11/4” C x C JOM100-807 11/2” C x C JOM100-808 2” C x C JOM100-809 21/2” C x C
WEBB# 184932 184933 151448 151449 163961 151450 151451 163962 151452 151453 151454 151455 151456 151457 151458 151459 151460
T-CS-2000 Series Jomar’s T-2000 Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP gas, natural and manufactured gas, LP gas/air mixtures and anhydrous-ammonia. They feature solid ball construction, reinforced P.T.F.E. seats, two piece standard port design. Double viton o-rings prevent stem leakage. Special 2000 psi seats available upon request. MFR# JOM100-953
DESC. 1/2” SS
WEBB# 184958
JOM100-954
3/4” SS
184951
JOM100-955
1” SS
184955
JOM100-956
11/4” SS
184956
JOM100-958
2” SS
184957
Locking Device 100-82-3LD Series • Type 2: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Size 3/4”. • Type 3: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Sizes 1” and 11/4”. MFR# JOM210-995
DESC. 3/4” Locking Device
WEBB# 111377
JOM210-996
11/4” Locking Device
111378
The VICTOR Propane Equipment Catalog
MFR# DESC. Model T-204 – FIP x FL JOM101-502 1/2” x 3/8” FIP x FL JOM101-503 1/2” FIP x FL Model T-204 – FL x FL JOM101-601 1/2” x 3/8” FL x FL JOM101-602 3/8” FL x FL JOM101-603 1/2” FL x FL JOM101-604 5/8” FL x FL Model T-204 – MIP x FL JOM101-702 1/2” x 3/8” MIP x FL JOM101-703 3/8” MIP x FL Model T-204 – System 3®
WEBB# 165040 58791 178937 184941 184942 184940 164856 164857
Jomar’s Blue Cap® II Manual Gas Valve, Model T-204 is American Gas Association Laboratories design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/air mixtures. The Blue Cap® II may be used as a 150lb. steam valve/600 W.O.G. MFR# Model T-204 – JOM101-401 JOM101-402 JOM101-403 JOM101-404
DESC. FIP x FIP 1/2” FIP x FIP 3/8” FIP x FIP 1/2” FIP x FIP 3/4” FIP x FIP
WEBB# 184937 184938 184939 184935
Models T-82 – Mini Valves Are designed for steam, water, oil or gas in commercial and light industrial use. The minivalves are competitive, conventional port, constructed of heavy duty forged brass, 100% Teflon seats and gland follower with double viton o-rings, to prevent stem leakage. Sells and installs cost wise as the leaky plug type, pet cock or gage cock without the leaks. MFR# JOM100-297 JOM100-299 JOM100-300
DESC. 1/8” FXM 1/4” FXM 1/4” FXF
WEBB# 111346 111348 151225
BALL VALVES
Jomar Gas Ball Valves
BALL VALVES
32 BALL VALVES Jomar Gas Ball Valves (cont.) Model T-203 – System 3®
T-2000N Series Blue-Cap®,
Equipped with all the features of the the System-3 has additional features making it the best value on the valve market today. • A 1/8” NPT side tap allows a manometer to be inserted into the valve to test line pressure, eliminating the test tee and the labor to install it. • It can be used in temperatures down to -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The handle can be reversed into a locked position. Combined with the tamper proof screw, the possibility of unauthorized use is sharply reduced. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • UL Listings: LP Gas, flammable liquids, natural and manufactured gas, air, N2,inert gases including helium, CO2. • The valve is rated 150 WSP/600 WOG. Remove the plug and you have a drainable ball valve for any fluid system. MFR# DESC. Model T-203 – FIP x FIP JOM102-301 1/4” IPS JOM102-203 3/8” FEM Side Tap JOM102-303 1/2” FEM Side Tap JOM102-304 3/4” FEM Side Tap JOM102-305 1” IPS Model T-203 – FL X FL JOM102-402 3/8” FL Side Tap JOM102-403 1/2” FL Side Tap JOM102-404 5/8” FL Side Tap JOM102-405 1/2” FEM x FL Side Tap
WEBB#
Jomar’s T-2000N Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP gas, natural and manufactured gas, LP gas air mixtures and anhydrous–ammonia. They feature solid ball construction, 2nd generation P.T.F.E. seats, two piece standard port design. Double Viton O-Rings prevent stem leakage. Special 2000 PSI seats available upon request. • Conforms to federal specification WW-V-35 • Latch-Lock Feature: Valve comes complete with latch lock, which may be locked in open or closed position. • Pressure Rating: 2000 W.O.G. MFR# DESC. Model T-CS-2000N-SS JOM100-952 1/2” JOM100-954 3/4” JOM100-955 1” JOM100-956 11 / 4” JOM100-958 2”
WEBB# 184958 184951 184955 184956 184957
Dimension in Inches
178938 151303 151304 151305 178939 151306 151307 151308 167285
Log Lighter and Lighter Parts MFR# DESC. WEBB# Log Lighter Valves JOM102-523 1/2” Chrome/Straight 198001 JOM102-523PB 1/2” Pol Bra/Straight 198002 JOM102-525 1/2” Chrome/Angle 198003 JOM102-525PB 1/2” Pol Bra/Angle 198004 Log Lighter Parts JOM102-527 Chrome Plate 198005 JOM102-528PB Pol Bra Plate 198006 JOM102-529 Chrome Key 198007 JOM102-530PB Pol Bra Key 198008
SIZE 1/4”
A 2.07
B 0.37
C 1.76
D 4.33
CV** 6.8
3/8”
2.07
0.37
1.76
4.33
6.8
1/2”
2.34
0.50
1.92
4.33
9.8
3/4”
2.80
0.69
2.40
5.83
25
1”
3.23
0.87
2.56
5.83
35
11 / 4”
3.57
1.00
2.74
7.76
47
11 / 2”
4.04
1.25
2.98
7.76
81
2”
4.63
1.50
3.17
7.76
105
** The CV Factor is the gallons of water per minute passed through the valve with 1 PSI pressure drop.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
BALL VALVES
33
Jamesbury brand, Series 300 standard port ball valves feature bubble tight shut off, high strength brass, and large port. The Series 300 are designed for use with hot and cold water, compressed air, natural and bottle gas, and low-pressure steam applications. Design
Max Pressure
Sizes 1/4" - 3"
Threaded-end Solder-end
1/2" - 2’
Male Hose-end
1/2" - 3/4"
Vented
1/4" - 2"
Max. Temp
Body/Trim Materials Brass
600 psi
400 F 316SS
200 psi
Brass Lever Handle Threaded Ball Valves MFR# JAM351T-14
1/4”
SIZE
WEBB# 168437
JAM351T-38
3/8”
168471
JAM351T-12
1/2”
168433
JAM351T-34
3/4”
170266
JAM351T-1
1”
170217
JAM351T-114 11 / 4”
170177
JAM351T-112 11 / 2”
170160
JAM351T-2
170248
2”
Series 6F Ball Valves Jamesbury brand, Series 6F ball valve’s 2-piece, full port, threaded configuration and 1000 psi pressure rating make it an ideal choice for applications where tight shutoff and low ∧p are required. Sizes
Max Pressure
Max. Temp
1/2" - 3"
1000 psi
500 F
Body/Trim Materials Carbon Steel 316SS
Carbon Steel Full Port Ball Valves MFR# JAM6F2236TT-12
1/2”
WEBB# 224378
JAM6F2236TT-34
3/4”
224381
JAM6F2236TT-1
1”
224375
JAM6F2236TT-114
11 / 4”
224377
JAM6F2236TT-112
11/2”
224376
JAM6F2236TT-2
2”
224379
The VICTOR Propane Equipment Catalog
SIZE
BALL VALVES
Series 300 Ball Valves
BALL VALVES
34 BALL VALVES Lockable Valve for Meter
Safe Ball ®
With tamper proof locking cover s.80 NPT — 3/4” & 1” • Special design • Hot forged brass • Pure Teflon® seats • -40°F +350°F temperature • Approved by AGA & CGA to ASME B16.33 & AGA Req’t #3-88 • Full port to DIN 3357 for maximum flow • Double seal system allows valve to be operated in either direction making installation easier • Two viton 0-rings at the stem for maximum safety • No maintenance ever required • 600 psi non-shock cold working pressure
The Gas Stops Here!
MFR# S80E41
DESCRIPTION WEBB# 3/4” Lockable Valve 250084
S80F41
1” Lockable Valve
Model 175 LWN & Model 175 LWIN • Gases: Natural or LP Gases • Service Designation: 175 PSIG • Options: Test Tap at inlet, brass or painted finish • 100% Leakage Testing: at 1.5 times service designation (263 PSIG); test methods meet or exceed D.O.T and ANSI B16.33 • ISO-EN 9002: Certified • Threads Conform: To ANSI B1.20.1 • Warranty: 10 years against leakage under normal operating conditions
Model 175 LWN
Model 175 LWiN
MFR# DESC. WEBB# Brass Locking Meter Valve w/Union JOM241-004B 3/4” JOM241-005B 1”
250085
* Pressure Tap Optional
CODE D (inch)
S80E41 3/4”
S800F41 1”
L (inch)
2.519
3.188
H (inch)
1,801
1.958
Pressure — Temperature Chart
Pressure Drop Chart
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
35
EXCESS FLOW, CHECK, FILLER, VAPOR EQUALIZING VALVES
Designed for top installation, in any position, in liquid or vapor service lines. They are intended for long lines or branch piping where tank mounted excess flow valves cannot suffice. Approximate Closing Flows Vapor SCFH (Propane)
Part Number
Body Material
Inlet Connection F. NPT
Outlet Connection (F. NPT)
Wrench Hex Flats
Liquid (GPM Propane)
25 PSIG Inlet
100 PSIG Inlet
Webb#
A1519A6
Steel
3"
3"
4"
225
45,000
82,000
189202
A1519A6
Excess Flow Valves for Liquid or Vapor Designed for liquid or vapor use for filling, withdrawal and vapor equalizing in container or line applications. They are intended for long lines or branch piping where tank-mounted excess flow valves are inadequate. Approximate Closing Flows
3282C
Part Number
Brass or Steel
A Inlet Connection M. NPT
B Outlet Connection F. NPT
C Wrench Hex Flats
D Effective Length (Approx.)
Liquid (GPM Propane) 4
12472 3272E 3272F
Brass
3/4"
3/4"
13/8"
13/8"
3272G A3272G
Steel
3282C 7574
Brass
A3292C
25 PSIG Inlet
100 PSIG Inlet
Webb#
1,050
1,700
186803
10
2,100
3,700
162452
15
2,800
5,000
162453
20
3,700
6,900
162584 162858
11/4"
11/4"
2"
15/16"
50
9,000
16,300
162587
11/2"
11/2"
21/4"
13/4"
90
15,200
28,100
162480
2"
2"
27/8"
17/8"
100
18,100
32,700
122
22,100
37,600
3292B A3292B
Vapor SCFH (Propane)
Steel
162588 162589 162590
Excess Flow Valves for Container Service Designed for mounting in threaded full or half couplings in container installations. They may be used for filling, withdrawal or vapor equalizing applications. The exceptionally low pressure drop makes them ideal for pump suction lines. If a riser pipe to the vapor space is used with these valves, the minimum inside diameter of the riser must be at least two times the valve thread size in order not to restrict flow to the side inlet ports. Approximate Closing Flows
A1537N4FA1519A6
Part Number
For use With This Type Coupling
A7537L4
Half
A7537L4F
Full
A7537N4
Half
A7537N4F
Full
A7537P4
Half
A7537P4F
Full
A7539R6
Half
A7539R6F
Full
A7539T6
Half
A7539T6F
Full
A7539V6
Half
A7539V6F
Full
The VICTOR Propane Equipment Catalog
Inlet Connection M. NPT
Outlet Connection NPT
Wrench Hex Flats
Liquid (GPM Propane) 75
2"
3"
2" Male and 11/4" Female
3" Male and 2" Female
25/8"
33/4"
Vapor SCFH (Propane) 25 PSIG Inlet
100 PSIG Inlet
13,000
25,600
125
25,000
42,500
150
30,500
52,000
150
32,100
55,500
200
39,400
68,300
250
51,100
88,700
Webb#
187042 189216
162594 162595
189217 187043 162473
189219
E X C E S S F L O W, C H E C K, F I L L E R, & V A P O R E Q U A L I Z I N G V A L V E S
Excess Flow Valves for Liquid or Vapor Line Service
E X C E S S F L O W, C H E C K, F I L L E R, & V A P O R E Q U A L I Z I N G V A L V E S
36 EXCESS FLOW, CHECK, FILLER, VAPOR EQUALIZING VALVES Excess Flow Valves for Vapor or Liquid Designed especially for filling, withdrawing or vapor equalizing in half and full coupling installations. Ideal for container service where welded-in dip pipes are not provided. For vapor use, mount in the bottom opening with a threaded dip pipe. For liquid use, mount in the top opening with a threaded dip pipe. These may also be installed in pipe lines provided the connection is made to the male inlet thread and not the female dip pipe connection. Approximate Closing Flows
A2137A
Inlet Connection M. NPT
Outlet Connection NPT
Wrench Hex Flats
Liquid (GPM Propane)
A2137A
2"
2" Male & 11/4" Female
27/16"
2139
3"
3" Male & 2" Female
31/2"
Part Number
Vapor SCFH (Propane) 25 PSIG Inlet
100 PSIG Inlet
Webb#
70
14,000
25,000
162415
125
26,500
46,000
189129
Excess Flow Valves for Liquid or Vapor Withdrawal These valves are designed for bottom mounting in consumer storage tanks for liquid service. They may also be top mounted for vapor service. These valves are designed especially for use with RegO® globe and angle valves. Approximate Closing Flows
Part Number
Inlet Connection M. NPT
A8013D
Wrench Hex Flats
3/4"
A8013D A8013DA
Outlet Connection M. NPT
11/4"
A8013DB
1"
Liquid (GPM Propane) 39
17/8"
11/4"
44 55
Vapor SCFH (Propane) 25 PSIG Inlet
100 PSIG Inlet
8,700
14,700
10.900
19,300
Webb# 187071 162491 187072
Excess Flow Valve for DOT Cylinders
3199W
Designed for use on portable systems with vapor or liquid including torches, heaters, lead melting burners, tar and asphalt burners, wallpaper steamers and other applications involving portable DOT cylinders. The POL inlet attaches directly to the cylinder valve and the outlet mounts to the regulator. Approximate Closing Flows
Part Number
Inlet Connection
Outlet Connection M. NPT
Wrench Hex Flats
Liquid (GPM Propane)
3199W
Male POL
1/4"
7/8"
.95
Vapor SCFH (Propane) 25 PSIG Inlet
100 PSIG Inlet
Webb#
265
500
186856
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
EXCESS FLOW, CHECK, FILLER, VAPOR EQUALIZING VALVES
37
Designed with unique 1” NPS threads on both Chek-Lok® outlet and adapter inlet. This helps prevent activation of the Chek-Lok® without use of the 7590U-10 adapter. Extra strength connection between body and adapter provides increased strength. An o-ring seal on adapter provides a gas tight seal before the adapter opens the equalizing stem.
7590U with Cap
These Chek-Loks® are also designed for use on permanent installations provided the excess flow valve is sized properly for the system and piping. NOTE: In some cases, it may be necessary to use an in-line excess flow valve to protect the downstream piping. This valve is not recommended for use as a liquid source for pumps. Part Number
Inlet Connection
7590U
3/4" M. NPT
7591U
11/4" M. NPT
Outlet Connection 15/8" UNF
Body Wrench Hex Flats
Approximate Effective Length
15/8"
17/16"
13/4"
111/16"
Cap Wrench Hex Flats 15/16"
Approximate Closing Flow, Liquid GPM (Propane)
Webb#
20
162748
35
204901
Union Style Adapters for 7590U and 7591H The 7590U-10 adapter must be used to connect to the 7590U and 7591U Chek-Lok, This insures a proper connection to open the check mechanism. A built in nylon gasket provides a gas tight seal. 7590U---10 Union Style Adapter
Part Number
Inlet Connection
Outlet Connection
Wrench Hex Flats
Webb#
7590U-10
15/8" UNF
3/4" F. NPT
13/4"
162762
Check-Lok® Liquid Evacuation Adapter for 7590U and 7591U Valves Designed specifically for use with RegO® 7590U and 7591U Check-Lok® Excess Flow Valves. Adapter’s operating handle opens and closes equalizing stem in the Chek-Lok® valve. Eliminates gas flow through Check-Lok® valve when installing or removing adapter. Use of RegO® adapter ensures proper connections and opening of the check mechanism.
7590U-20
Part Number
Inlet Connection
Outlet Connection
A Wrench Hex Flats
B Approximate Length
Webb#
7590U-20
15/8" F. UNF
3/4" F. NPT
13/4" F. NPT
41/8" F. NPT
217164
7572FC and 7580FC Check-Lok® Valves* Design is the original Check-Lok. It has provided the LP-Gas industry with quality and dependable performance for over 35 years.
7572FC
7580FC
Part Number
Inlet Connection
7572FC
3/4" M. NPT
7580FC
11/4" M. NPT
Outlet Connection 3/4" F. NPT
Body Wrench Hex Flats
Approximate Effective Length
13/8"
15/8"
13/4"
11/2"
Cap Wrench Hex Flats 15/16"
Approximate Closing Flow, Liquid GPM (Propane)
Webb#
20
162743
35
162746
*Soon to be obsolete, not manufactured after July 1, 2002.
Adapters for the 7572FC and 7580FC These adapters must be used to connect to the 7572FC and 7580FC Check Loks to open the check mechanism properly. A built in nylon gasket provides a gas tight seal. 7572C-14A
7572C-15A Part Number 7572C-14A 7572C-15A
The VICTOR Propane Equipment Catalog
Inlet Connection 3/4" M. NPT
Outlet Connection 3/4" F. NPT 3/4" M. NPT
Body Wrench Hex Flats 13/8"
Webb# 162761 162478
E X C E S S F L O W, C H E C K, F I L L E R, & V A P O R E Q U A L I Z I N G V A L V E S
7590U and 7591U Check-Lok® Valves
E X C E S S F L O W, C H E C K, F I L L E R, & V A P O R E Q U A L I Z I N G V A L V E S
38 EXCESS FLOW, CHECK, FILLER, VAPOR EQUALIZING VALVES Double Check Filler Valves for Forklift, Motor Fuel and RV Tanks Designed to provide fast filling of forklift, motor fuel, and recreational vehicle tanks. Part Number (w/Lanyard & Cap) 7647SA 7647SC
A Hose Connection
B Tank Connection M. NPT
13/4" ACME
3/4"
C Wrench Flats
D Effective Length (Approx.)
11/2"
31/16"
13/4"
21/4"
Propane Liquid Capacity at Various Differential Pressures (GPM) 10 PSIG
20 PSIG
30 PSIG
40 PSIG
50 PSIG
14
20
24
27
50
Webb# 190841 162756
7647SC
Double-Check Filler Valves for Large Motor Fuel and ASME Tanks Designed to provide fast filling of large motor fuel and ASME domestic tanks. The 6579 Series incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations. 7579
6579
Part Number (w/ Cap Only) 7579 6579
ACME Hose Connection
Tank Connection M. NPT
13/4"
Wrench Hex Flats
11/4"
17/8"
Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG
10 PSIG
25 PSIG
50 PSIG
75 PSIG
Webb#
50
70
111
157
192
162745
78
110
174
246
301
162467
Double Check Vapor Equalizing Valves for ASME and DOT Containers Designed to facilitate loading operations by providing equalization of pressures in the supply and storage containers. The supplementary excess flow valve closes when the flow from the container being filled exceeds a predetermined rate. 7573AC
The 7573 Series is designed for use in bulk delivery systems and motor fuel containers. The 3183AC is designed for use in delivery trucks and other large containers. Part Number
Type
7573A
Basic
7573AC
w/Cap & Chain
ACME Hose Connection
Tank Connection M. NPT
Wrench Hex Flats
Approximate Closing Flow at 100 PSIG Inlet Pressure (SCFH/Propane Vapor)
11/4"
3/4"
11/4"
4,100
Webb# 162744 189179
Back Pressure Valves for Container or Line Applications Designed to provide protection of a container opening when desired flow is always into the vessel. May be used in line applications where flow must be limited to one direction.
3146
When used with the appropriate single check fill valve, the combination forms a double check filler valve suitable for use in filling of bulk storage tanks.
Part Number
Brass or Steel
3146
Brass
A3146
Steel
3176
Brass
A3176 A3186 A3196
Steel
A Inlet Connection F. NPT 3/4"
B Outlet Connection M. NPT 3/4"
C Wrench Hex Flats 13/8"
D Effective Length (Approx.) 15/16"
Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG 11
10 PSIG 16
25 PSIG 25
50 PSIG 36
Webb# 162578 187012 162580
11/4"
11/4"
2"
13/8"
28
40
63
89
2"
2"
27/8"
27/16"
124
175
276
391
162582
3"
3"
4"
35/16"
297
420
664
939
162583
162581
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
EXCESS FLOW, CHECK, FILLER, VAPOR EQUALIZING VALVES
39
Class 200 — Y-Pattern — Threaded Ends Features: • Screwed Cap • Always install with pressure under the disc in vertical or horizontal position. An arrow cast on the body indicates the correct direction of flow. • MSS-SP-60. Type 3 Working Pressures Non-Shock: Swing Check valve
300 psi Steam, Basic Rating 1000 psi Cold Working Pressure – 1/4” to 2” (6mm – 50mm) 600 psi Cold Working Pressure – 21/2” to 3” (65mm – 80mm) MFR# CRV36-14
1/4”
SIZE
WEBB# 6057
CRV3612
1/2”
6059
CRV36-34
3/4”
6060
CRV36-1
1”
6061
CRV36-114
11 / 4”
6062
CRV36-112
11 / 2”
6063
CRV36-2
2”
6064
Bronze Lift Check Valves Class 300 — Threaded Ends Features: • MSS-SP-80, Type 1 Suggested to be used on a compressor or similar application with constant pulsating supply. Must be installed horizontally only. Working Pressure Non-Shock: 300 psi Steam, Basic Rating Lift Check Valve
1000 psi Cold Working Pressure MFR# CRV366E-34
1/4”
SIZE
CRV366E-1
1”
WEBB#
CRV366E-114 11 / 4” CRV366E-112 11 / 2” CRV366E-2
The VICTOR Propane Equipment Catalog
2”
6159
E X C E S S F L O W, C H E C K, F I L L E R, & V A P O R E Q U A L I Z I N G V A L V E S
Bronze Swing Check Valves
INTERNAL VALVES & ACCESSORIES
40
INTERNAL VALVES & ACCESSORIES 11 / 4” Threaded Internal Valve for Small Capacity Pumping Systems and Bobtail Vapor Equalization Designed primarily for use with LP-Gas and anhydrous ammonia as a main valve on small capacity pumping systems, NH3 nurse tanks and in-line installations. It may also be installed in the vapor equalizing opening on bobtail delivery trucks. Installation is quick and easy, and it fits in both full and half couplings, as well as, in-line applications. The valve may be activated manually by hand or cable. A3209R050
Closing Flow (GPM)
Part Number
Inlet Connection M. NPT
Outlet Connection F. NPT
LP-Gas
A3209R050
11/4"
11/4"
A3209R080
11/4"
11/4"
LP-Gas Vapor Capacity (SCFH/Propane)
Accessories
NH3
25 PSIG Inlet
100 PSIG Inlet
Thermal Latch
Pneumatic Actuator Webb#
50
45
13,300
22,900
A3209TL
A3209PA
251120
80
72
15,700
26,700
A3209TL
A3209PA
251118
11 / 4” Threaded Angle Internal Valve for Motor Fuel Dispensers and Small Capacity Pumping Systems Designed primarily for use with LP-Gas and anhydrous ammonia as a main valve on pump systems with small capacity, such as motor fuel dispensers. It may also be installed in bottom liquid withdrawal openings in NH3 nurse tanks or the vapor equalizing opening of bobtail delivery trucks. Installation is quick and easy, and must be installed in a modified half coupling or the equivalent. The valve may be actuated manually by cable or pneumatically.
A3210A065
Closing Flow (GPM)
Part Number
Inlet Connection M. NPT
Outlet Connection F. NPT
LP-Gas
NH3
A3210A065
11/4"
11/4"
65
58.5
LP-Gas Vapor Capacity (SCFH/Propane)
Accessories
25 PSIG 50 PSIG 75 PSIG 100 PSIG Inlet Inlet Inlet Inlet
Pneumatic Actuator
Webb#
A3210PA-R1
189205
17,000
22,250
26,500
30,000
Flomatic® Internal Valves for Bobtail Delivery Trucks, Transports and Large Stationary Storage Tanks Designed primarily for LP-Gas and anhydrous ammonia liquid withdrawal on MC331 bobtail delivery trucks, transports and large stationary storage containers with flanged connections. The valve is fully automatic, opening and closing as the pump is turned on or off.
A7883FK
Part Number
Inlet Connection ANSI Flange
Outlet Connection ANSI Flange
Strainer Width
Base Width
Height Overall from Height Indicator (Approx.) to Base
A7883FK
3"-300#
3"-300#
43/4"
81/4"
107/8"
413/16"
A7884FK
4"-300#
4"-300#
53/4"
10"
111/4"
415/16"
Accessories Filter
3-Way Valve
A7884-201
A7853A
Webb# 162571 193215
Threaded Internal Valves for Bobtail Delivery Trucks, Transports and Stationary Storage Tanks Designed primarily for use with LP-Gas and anhydrous ammonia for liquid withdrawal; vapor transfer or vapor equalization of bobtail delivery trucks, transports, stationary storage tanks, and in-line installations. The valve may be operated manually by cable or pneumatically. A3212A105
Part Number A3212A105 A3212A250
Inlet Connection M. NPT
Outlet Connection F. NPT
2"
2"
3"
3"
A3213A150 A3213A300 A3213A400
Closing Flow (GPM) Half Coupling LP-Gas
NH3
Closing Flow (GPM) Full Coupling LP-Gas
NH3
105
95
65
59
250
225
130
117
150
135
125
113
300
270
250
225
400
360
325
293
Accessories Thermal Latch
Pneumatic Actuator Webb#
A3212TL
A3212PA
A3213TL
A3213PA
189206 187019 190677 187020 162569
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
ADAPTERS, CONNECTORS & FITTINGS
41
Part Number
Material
Style
3175
Style A For Liquid Filling
Style B For Liquid Filling
Brass
A
Brass Nut & Steel Nipple
A3185
B
A Steel B
A3195
Style C For Vapor Equalizing
Style D For Vapor Equalizing
3181
13/4"
C
3181A
2"
27/8"
162687 162688
13/16"
21/16"
31/8"
186854
2"
31/4"
113/16"
21/8"
35/8"
162692
13/4"
3/4"
2"
27/8"
11/4"
21/4"
13/16"
2"
31/4"
113/16"
1"
D
11/4"
21/8"
31/8" 35/8"
13/32"
11/4"
3/4"
1"
3191
3/4"
Webb# 186853
21/4"
1/2"
Brass
Overall Length
11/4"
3/8"
3171 3171A
Hose End to Nut
35/64"
3/4"
A3175 A3175A
3/4"
Tailpiece Bore
1"
3185 3195
Coupling Connection (F. ACME)
1/2"
3175B
3175A
Hose Connection (M. NPT)
17/32" 11/16"
13/4" 21/4"
13/16"
27/16"
2"
31/4"
162689 187016 162693 190678 162686 162690
15/16"
17/8"
31/8"
162691
13/16"
21/8"
35/16"
186855
ACME Check Connectors for Lift Trucks These brass connectors are especially designed to join the carburetor fuel line to the service valve on lift truck cylinders. Sturdy, long lasting ACME threads allow quick, hand-tight assembly that provides for quick and simple cylinder replacement. Back checks automatically close in each connector when disconnected.
7141M
7141F
The 7141M couples directly to the service valve. An integral O-ring is designed to seal before the internal check opens, aiding in product loss prevention. A gasket at the ACME thread is a secondary seal when the connectors are tightened together. The connector fits RegO® lift truck cylinder filling adapters for fast, convenient filling. The 7141F accepts fuel line adapter and couples directly to the 7141M. The O-ring seal in the 7141M is designed to seal before the internal check opens to allow product to pass through the connection. The knurled coupling eases threading and the ACME threads provide rapid effortless make-up, even against LP-Gas pressure. Part Number
Protective Cap Application
Inlet
7141M
Service Valve
3/8" F. NPT
7141F
Fuel Line
11/4" F. ACME
Outlet
Rubber
11/4" M. ACME 7141M-40 1/4" F. NPT
--
Brass
Webb#
7141FP
162755
--
162754
Unloading Adapters for Container Evacuation Designed to provide an efficient means of evacuating an LP-Gas container for relocation or repair. They thread directly onto the 13/4” ACME male hose connection of RegO® Filler Valves used on RegO® Double Check Filler Valves and Multivalves®. The unloading adapters can be used to withdraw liquid provided the container is equipped with a dip pipe extending from the filler valve to the bottom of the container. 3119A
3120
Part Number
Style
3119A
In-Line
3120
Angle
The VICTOR Propane Equipment Catalog
Filler Valve Connection 13/4" F. ACME
Hose Connection
Webb#
11/4" M. ACME 162830 3/4" F. NPT
162831
A D A P T E R S, C O N N E C T O R S, & F I T T I N G S
Short Type Hose Couplings for Vapor and Liquid Service
A D A P T E R S, C O N N E C T O R S, & F I T T I N G S
42
ADAPTERS, CONNECTORS & FITTINGS Filler Hose Adapters These adapters are designed with minimal flow restriction and recommended for use on the outlet of the LP-Gas delivery truck filler hose. If the controlled bleed off of the connection indicates the filler valve on the tank being filled has failed to close, the hose adapter should be left in place on the filler valve and disconnection should be made at the regular filler hose coupling. (Repair of the filler valve must be made as soon as possible). An integral check valve in these adapters helps prevent further loss of product. The standard filler valve cap should be attached to these adapters when left on the container.
3179A 7577V
Part Number
Built-in Vent Valve
7577V
Yes
3179B
No
Filler Valve Connection
Hose Connection
13/4" F. ACME 13/4" M. ACME
Webb# 162764 162763
ACME Adapters
Gasket (Furnished with adapter)
ACME x Female NPT
Part Number
Material
A M. ACME
B F. NPT
C Hex
1/4"
5764A
D
For Spare E Gasket Order Diameter Part No.
11/2"
3/8"
5764B 13/4"
5764C
1/2"
Webb# 162464 186865
3/4"
13/4"
A2697-20R
162465
17/8" 3/4"
186866
5764E
1"
162698
5764G
11/2"
5764D
Gasket (Furnished with adapter)
ACME x Male NPT
Brass
31/4" 5764H
(CGA 510) POL
970 Hard Nose POL
Part Number
Material
5763D
A M. ACME 11/4"
5765D 5765E 5765F
(CGA 510) POL
970AX Hard Nose POL w/Excess Flow
Brass
5769H
3199W Heavy Duty Hard Nose POL w/Excess Flow
13/4"
B F. NPT 3/4"
1"
21/8"
C Hex
D
11/4"
13/4"
7/16"
17/8"
11/16"
21/8"
3/4"
A3194-BR
27/8"
17/8"
21/2"
31/4"
31/2"
21/8"
1/2" 3/4"
13/4"
A5765F
1"
31/4"
2"
Webb# 189153 186867
A2697-20R
162700
A3194-BR
162706
17/32" 11/16"
13/4"
23/16"
7/8"
A2697-20R
15/16"
11/4"
A5769H
A2797-20R
162702
33/8"
5765C
Steel
13/4"
For Spare E Gasket Order Diameter Part No.
2"
A5765D A5765E
35/8"
11/4" 31/4"
5769J
50-70 Micron Filter
31/2" 2"
31/4"
27/8"
17/8"
189211 162701 189212
A3194-BR
162707
Male POL Swivel Adapters Closing Flow (Propane)
(CGA 510) POL
970HT Soft Nose POL w/Handwheel
Part Number
Material
A M. NPT
B Hex
C Drill
970 7/8"
970AX
5/16"
3199W 970HT
Brass
1/4"
13/8"
3/16"
D
Vapor at 100 PSIG Inlet (SCFH)
Liquid (GPM)
Webb#
23/8"
--
--
191818
25/64"
404
110
187003
27/16"
450
0.95
186856
--
--
243117
350
.95
23/32"
3188A
3188 Heavy Duty Hard Nose POL w/Excess Flow
3188B 3188C
11/8"
5/16"
21/2"
700
1.9
1180
2.9
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
ADAPTERS, CONNECTORS & FITTINGS
(CGA 510) POL
2906G Male POL x Female NPT
Part Number
Material
A F. NPT
B
C Hex
D
Webb#
2906G
Brass
1/2"
2"
11/8"
1/4"
162828
Part Number
Material
A
2906D
3/8" M. NPT
2906F
3/8" SAE Flare
2906E
Brass
Male POL x Male NPT and SAE Flare
(CGA 510) POL
Female POL x Female NPT and Female POL
Part Number
A F. NPT 1/4"
5760B
3/8"
5760C
1/2"
Brass
15/16"
11/32"
7/8"
C Hex
B
162826 186523 PIG1006
D Diameter
Webb#
13/32"
162457
35/64"
162458
43/64"
17/8"
13/8"
5760S
POL (CGA 510)
21/8"
11/8"
A M. NPT
9/32"
11/8"
3/4"
Material
162459 162460
13/32"
B
C Hex
163431
D Diameter Webb#
5761A
1/4"
3/16"
186863
5761B
3/8"
13/32"
186864
Brass
1/2"
15/8"
11/8"
162461
7/16"
3/4"
5761D
Part Number
186524 PIG1007
5760D
Part Number
Alt. Code
189132
21/4"
15/8"
Webb#
162827 186522 PIG1005
1/2" SAE Flare
5760A
5761C
(CGA 510) POL
Material
D Diameter
21/16"
5/8" SAE Flare
(CGA 510) POL
C Hex
B
162462
Female POL x Male NPT
Miscellaneous Adapters Part Number
Material
1328 1331 1332
The VICTOR Propane Equipment Catalog
Brass
A Male
B Female
5/8"-18 UNF
5/8"-18 UNF
3/4"-16 UNF
3/4"-16 UNF
7/8"-14 UNF
7/8"-14 UNF
C 1/2" Hose
Barb
D
E
F
Webb#
13/16"
2"
11/2"
162816
15/16"
21/8"
11/16"
21/2"
13/4"
162817 162818
A D A P T E R S, C O N N E C T O R S, & F I T T I N G S
POL Adapters
43
MISCELLANEOUS EQUIPMENT
44
MISCELLANEOUS EQUIPMENT 1” Rotogauges® for Large Mobile and Stationary Containers Rotogauges® are designed to provide an accurate determination of LP-Gas or anhydrous ammonia container contents. They mount in a standard 1” NPT coupling on large mobile or stationary containers. To operate the Rotogauges®, the vent valve is opened and the dip tube rotated slowly from the container vapor space to the liquid space. The difference in appearance of the discharge indicates when the liquid level is reached. Dial readings then indicate the percentage of product in the container.
PART # RGOA9091R
WEBB# 162596
RGOA9092R
162597
RGOA9093RS
190686
RGOA9093TS
162598
Part Number
Container Size
Webb#
All Sizes
189231
Over 1200 U.S. Gallons
162682
Service
A9091-18L A9091-18LX
LP-Gas
Part Number
162599
For Use With LP-Gas
RGOA9094TS
162600
RGOA9095RS
162602
For Mobile For Stationary or Stationary Containers Containers Only
RGOA9095TS
162678
RGOA9091-M24.0
189233
RGOA9094RS
RGOA9091-M36.0
162679
RGOA9091-M48.0
162680
RGOA9091-M60.0
162681
RGOA9091-M72.0
162988
For Container Inside Diameter For Use With NH3
For Mobile or Stationary Containers
For Stationary Containers Only
Ellipsoidal Heads Side Mounted
End Mounted
Hemispherical Heads Side Mounted
End Mounted
9091RM24
--
AA9091RM24
--
30" - 45"
30" - 75"
30" - 45"
30" - 45"
9092RM36
--
AA9092RM36
--
46" - 61"
76" - 108"
46" - 61"
46" - 61"
9093TSM48
9093RSM48
AA9093TSM48
AA9093RSM48
62" - 79"
109" - 147"
62" - 79"
62" - 79"
9094TSM60
9094RSM60
AA9094TSM60
AA9094RSM60
80" - 99"
--
80" - 99"
80" - 99"
9095TSM72
9095RSM72
AA9095TSM72
AA9095RSM72
100" - 147"
--
100" - 147" 100" - 147"
Sight Flow Indicators for Bulk Plants Designed to promote maximum pump efficiency, these indicators enable bulk plant operators to visually inspect liquid flow conditions. With glass on both sides of the indicator, flow can be observed from either side, even under some poor light conditions. The integral swing check also serves as a back-check valve to prevent reverse flow and product loss if the hose falls in a loading operation.
A7794
By installing an indicator on the upstream side of the plant pump, suction conditions can be observed and the pump speed adjusted to obtain the maximum possible flow rate without cavitation. Additionally, if an indicator is installed in the piping at the loading rack, just ahead of the loading is installed in the piping at the loading rack, just ahead of the loading hose, the operator can maintain a constant check on pump conditions. Both installations are designed to allow for observation to provide maximum pump efficiency and assure safe plant pump operation. In compressor operations a sign flow indicator installed in the liquid line will give a visual indication when the tank car or transport is emptied. Compressor operation can then be immediately reversed to start recovery of the vapor. Part Number
Inlet/Outlet Connections
Length
Webb#
A7794
2" F. NPT
53/4"
162712
A7796
3" F. NPT
73/8"
162713
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
MISCELLANEOUS EQUIPMENT
45
A2141A6L
Designed especially to provide pull-away protection for LP-Gas and anhydrous ammonia transfer operations including transport and delivery truck loading and unloading, engine fuel container filling and miscellaneous cylinder filling operations. When properly fastened to the inlet end of the discharge hose, the valve is designed to stop gas escape from both upstream and downstream lines in the event of a pull-away. An excessive tension pull causes the valve to automatically separate, closing two internal back pressure checks. Only a few cubic centimeters of gas escape at the instant of separation. It is recommended that a convenient means be provided to safely remove the pressure from the line upstream of each coupling half to enable reassembly of the valve. To reassemble, simply push the male half firmly into the female half until the retaining balls slip into the retaining groove. Check for leaks after reassembly.
NOTE: It is recommended that pull-away valves be safety-tested at least monthly to confirm that they will separate properly in the event of a pull-away. Dry nitrogen or other inert gas is suggested for a source of pressure during such tests. Part Number A2141A6
Inlet/Outlet Connections F. NPT 3/4"
A2141A6L A2141A8 A2141A8L
1"
Disconnect Force Approx-lbs.
Reconnect Force Approx-lbs
Length of Valve
LP-Gas Liquid Flow Capacity at Various Differential Pressures (GPM) 5 PSIG
10 PSIG
25 PSIG
50 PSIG
130
80
37/8"
11
16
25
36
75
50
49/16"
21
30
47
67
Webb# 162683 162684 187008
A2141A10
11/4"
160
25
55/8"
52
75
120
170
189203
A2141A16
2"
300
50
145/16"
250
350
550
750
187007
2” “Swing-Check” ESVs for Bulk Plants Especially designed for installation in liquid transfer lines at LP-Gas or anhydrous ammonia bulk plants to provide for quick shut-off of liquid or vapor flow in the event of an accidental pull-away or hose rupture, both of which can cause a fire.
A7605B
Part Number
For use Only With:
Inlet/Outlet Connections
A7605B
NH3
2" F. NPT
Liquid Low Capacity at 10 PSIG Pressure Drop (GPM) Webb# 427 (NH3)
217165
11/4” ESV for LP-Gas Bulk Plants Especially designed for installation in vapor transfer lines at LP-Gas bulk plants to provide for quick shut-off of vapor or liquid flow in the event of an accidental pull-away or hose rupture, both of which can cause a fire. Flow Capacity
A7781AF
Part Number
For use Only With:
Inlet Connection M. NPT
A7781AF
LP-Gas
11/4"
The VICTOR Propane Equipment Catalog
Outlet Connection F. NPT
Vapor at 100 PSIG and 10 PSIG Pressure Drop SCFH
11/4"
26,000
Liquid at 10 PSIG Pressure Drop GPM Webb# 55
190691
MISCELLANEOUS EQUIPMENT
Pull-Away Valves for Transfer Operations
46
MISCELLANEOUS EQUIPMENT
MISCELLANEOUS EQUIPMENT
ESV Remote Cable Controls Part Number
Description
Webb#
7609-50
Transfer hose cable release kit. Attaches to ESV and hose for automatic closing as hose stretches.
189188
7606RM
Remote manual cable release kit. Permits manual closing of one or more ESVs from remote location.
189187
7606RT
Remote thermal cable release kit. Provides high temperature closing of ESV. Required if ESV is more than 5 feet from nearest end of hose.
7606RM-1
100’ roll of extra cable.
A3219-34
Replacement fusible link for 7606RT.
187021
7605B-20
Replacement fuse latch assembly for 7605B.
189183
1/4" nylon tubing sold per foot, 1000’ per roll
Alt. Code
Webb#
VCT020064-6
253198
ESV Pneumatic Controls Part Number
Description
Webb#
7781AFPN-1 Cylinder assembly kit to convert 7781AF ESVs to pneumatic shutdown.
241753
7605APN-1
Cylinder assembly kit to convert 7605B ESVs to pneumatic shutdown.
241752
7605PN-50
Pneumatic remote shutdown system kit, complete with 100’ of tubing, fittings, 1 charging valve assembly and 1 remote shutdown valve assembly.
189185
7605APN-8A Extra shutdown valve assembly.
246564
7605A-BT
100’ roll of 1/4" pneumatic tubing.
189182
7605AP-16
1/4" tubing tee, w.nuts.
186935
7605AP-15
1/8" NPT x 1/4" tubing, straight connector.
186934
Hose End Adapters for DOT Cylinder Filling Designed to provide quick and easy filling of DOT cylinders with POL or Type 1 connections. This adapter may be used with hydraulic and electric automatic systems or with manual systems in conjunction with a RegO® 7901TB Quick Acting Shut-Off valve. These filling connectors have an extended connection on the handwheel, which make it possible to connect the leading hose to valves on cylinders with fixed collars. The handwheel is well outside the collar for easy operation. 7193D-10
Part Number
Application
7193D-10
Filling of DOT Cylinders with POL Connectors
7193U-10
7193U-10
Filling of DOT Cylinders with Type 1 Connectors
Inlet Connection
1/4" M. NPT
Outlet Connection
Materials
Webb#
M. POL (CGA 510)
Brass and Stainless Steel
186884
Type 1 Connection (115/16" M. ACME)
Brass
186886
Connector for DOT Cylinder Filling Adapter The 7193T-10 is designed for use on the 7193D-10 Filling Adapters. Connector allows adapter to be used on the 15/16 M. ACME & F. POL connections of Type 1 valves. Part Number 7193T-10
7193T-10
Application Converts 7193D-10 Adapter from POL to a Type 1 Connection
Inlet Connection
Outlet Connection
M. POL CGA 510
Type 1 Connection (115/16" M. ACME)
Materials
Webb#
Brass
162472
Marshall Brass Type 1 Fittings & Adaptors
Type 1 ACME Fill Fitting
Type 1 ACME Appliance Side Fitting x 1/4” Male Pipe
Threads directly onto the exterior MFR# 15/16” ACME threads on the Type 1 cylinder valve with a smooth right hand G-820 motion. Once connected, the cylinder can be filled quickly and easily.
Appliance side swivel nut fitting is female 15/16” ACME x 1/2” M.P.T. As the appliance side of the Type 1 connection, it makes a positive connection by threading on to the ACME threads of the valve with a user-friendly right hand turn motion. MFR# DESCRIPTION WEBB# G-1851-A03 POL Green 71–100 BTU 242866 G-1851-A02 POL Black 0–70 BTU
182659
G-1850 Evaculation Fitting Threads onto Type 1 cylinder valves just like the appliance side, swivel nut fittings. For purging only.
MFR# G-1850
WEBB# 182661
WEBB# 182658
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
MISCELLANEOUS EQUIPMENT
47
The 7193-10A is designed to provide quick and easy attachment of the filling hose to DOT cylinders equipped with RegO® 714M Check connectors. 7193-10A Part Number
Application
7193L-10A
Filling of Fork Lift Cylinders
Inlet Connection
Outlet Connection
Body Material
1/4" M. NPT
11/4" F. ACME
Brass
Accessories Adapter
Webb#
5760A
162471
Lever Operated Hose End Adapter for Fork Lift Cylinder Filling Designed to drastically reduce labor and time when continuously filling large numbers of lift truck cylinders equipped with RegO® 7141M check connectors. 7193K-10B
Part Number
Application
7193K-10B
Lever Operated for Quick Filling of Fork Lift Cylinders
Inlet Connection
Outlet Connection
Materials
Webb#
1/4" F. NPT
Quick Disconnect Yoke
Brass and Steel
162470
Quick Connect POL Filling Adapter The 7193R-10 is designed for use in LP-Gas filling systems including fill rooms and dispensing stations. The quick acting lever allows fast connection to POL type (CGA 510) cylinder valves. It fits both compact and heavy duty cylinder valves commonly found on 5 to 100 lb. DOT LP-Gas cylinders. 7193R-10
Part Number
Application
7193R-10
Lever Operated for Quick Filling of Cylinders with POL Outlets
Inlet Connection
Outlet Connection
Webb#
1/2" F. NPT
Fits Female POL
189171
Vent Valves
3165S
3165C
Especially designed to bleed off liquid or vapor pressures trapped in transfer lines. When installed in the downstream boss of RegO® globe and angle valves used at the end of a liquid transfer hose, the bleeder valve allows for the controlled venting of the product and indicates to the operator that the valves are closed and he can disconnect the coupling. They may also be used as a fixed liquid level gauge where the dip tube is part of the container. Accessories Part Number 3165C 3165S
TSS3169
TSS3169
Service LP-Gas Only
Connection
Actuation
Warning Plate Kit
Knurled 1/4" M. NPT
LP-Gas & NH3
Slotted
Webb# 162449
2550-40P
Tee Handle
162450
Spanner Wrench for ACME Connectors 3195-50
This aluminum spanner wrench is especially designed for use with 21/4” and 31/4” ACME couplings, adapters and caps. Part Number
For Use With ACME Connector Size
Webb#
3195-50
21/4" & 31/4"
162697
The VICTOR Propane Equipment Catalog
MISCELLANEOUS EQUIPMENT
Hose End Adapter for Lift Truck Cylinder Filling
MISCELLANEOUS EQUIPMENT
48
MISCELLANEOUS EQUIPMENT Fixed Liquid Level Gauges Especially designed to provide a visible warning when containers are filled to the maximum permitted filling level. At the start of the filling operation, with the vent stem opened, the valve discharges vapor. When the maximum permitted filling level is reached, the valve discharges liquid. These valves are normally furnished with a 12”, 3/16” O.D. dip tube and incorporate a No. 54 drill size orifice. An optional instruction plate with “Stop Filling When Liquid Appears” may be ordered for use with these valves.
Part Number
Service
Connection
Actuation
Dip Tube Length
Knurled
*
3165CF 3165CF12.0
3165CF12.0
TSS3169.SF120
LP-Gas Only
TA3169F12.0
Warning Plate Kit
Slotted Tee Handle
LP-Gas & NH3
Webb#
186851
1/4" M. NPT
3165SF12.0
Accessories
12"
2550-40P 189251
* Dip tube must be ordered separately. Add to suffix. Example: 1” Dip Tube = 316511.0
Combination Valve for Bulk Storage Containers Designed for installation on bulk storage containers, this valve combines a pressure gauge mounting and provision for a fixed tube liquid level gauge. The shut-off valve prevents the pressure gauge from being subjected to constant pressure, thereby prolonging its life and accuracy. The valve may be closed, and the vent valve opened to vent pressure from the gauge to permit replacement. A2805C
For fixed liquid level gauging, the valve can be mounted at the maximum permitted filling level. When equipped with a dip tube threaded 1/8” M. NPT, it can be installed at any convenient level. Part Number A2805C
Container Connection 3/4" M. NPT
Service Connection
Liquid Level Vent Webb#
1/4" F. NPT for
Knurled
Gauge Mounting
162685
Needle Valves These valves are high quality, “true” throttling valves. Unlike most so-called needle valves, both the body seat and stem are tapered to provide fine, precise control over a wide range of adjustment without stem galling. 1224WA
The 1224 may be used as a small, inexpensive shut-off valve between a pressure gauge and bulk storage container to allow for convenient gauge replacement. The 1314, 1316 and 1318 provide taper pipe thread by left hand hose connection threads and are useful in a wide range of torch and fuel burner applications where an accurate throttling action is required. Part Number
Inlet Connection
Outlet Connection
1224WA
1/4" M. NPT
1/4" M. NPT
1314WA 1316WA 1318WA
9/16" - 18 L.H. 1/4" M. NPT
Height
Length
Webb# 186802
1/8" M. NPT 1/4" M. NPT 9/16" - 18 L.H.
19/16"
13/4"
189122 189123
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
DIAGRAMS
Domestic Installation
Service Valve 7556R12.0
The VICTOR Propane Equipment Catalog
DIAGRAMS
Bulk Transport Truck
49
DIAGRAMS
50
DIAGRAMS Bobtail Delivery Truck
Emergency Shut Off Valves
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
DIAGRAMS
DIAGRAMS
Bulk Storage Plant
A3186
The VICTOR Propane Equipment Catalog
51
R EPAIR KITS
52
REPAIR KITS Repair Kits Available by Part Number ECII Part # 901 Series 903 Series
A2141A6 Series A2141A8 Series A2141A10 A2141A16
Repair Kits Available
Contents
903-50
Bonnet stem and seat disc assembly; large handwheel, self tapping screw
903-51
Bonnet stem and seat disc assembly; small handwheel, self tapping screw
A2141A6-50 A2141A6M A2141A8-50 A2141A8M A2141A10-50 A2141A10M A2141A16-50
Instruction Sheet # 903-300
O-ring seal for female connector Male Coupling O-ring seal for female connector
A2141A-302
Male Coupling O-ring seal for female connector Male Coupling O-ring seal for female connector
A2141A-303
A2141A16M
Male Coupling
A3209A Series
A3209A-50
Bearing; cam; gasket; main seat disc assembly; retaining ring, seal-o-ring; seat disc
A3209A-301
A3210A Series
A3210A-50
Bushing; gasket; jam ring; main seat disc assembly; upper and lower retaining rings; o-ring; seal rings (2); seat disc
A3210A-301
A3212A-K Kits Excess Flow spring; o-ring A3212A Series
A3212A-50
Bearing; cam; gasket; o-rings; seat disc; stem packing
A3213A-K Kits Excess Flow spring; o-ring A3213A Series A3217 Series
6532, 6533, 6542, 6543 Series Filler Valve
A3213-800
A3213A-50
A3213A-300
A3217F-50
Dust seal; jam ring; stem o-ring; stem seals (3); stem spring; stem washer
A3217F-300
Cotter pin; dust seal; inner and outer stem bearing; jam ring; main and pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper and lower flange seal o-ring; wear button
A3217F-302
Dust seal; inner stem bearing; jam ring; lower flange seal gasket; main seat disc; outer stem A3217F-80G bearing; pilot seat disc; poppet seal o-ring; Gasket flange retaining ring; roll pin (2); seat o-ring; stem oring; stem seals (3); upper flange seal gasket; wear button
A3217F-302G
A3219F-80 O-ring flange
Bumber; cotter pins (3); dirt seal; inner and outer stem bearing; lever release spring; main seat disc; poppet seat disc; pivot pin locknut; poppet bearing; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; upper and lower flange seal o-ring
A3219F-302
A3219F-80G Gasket flange
Bumber; cotter pins (3); dirt seal; inner stem bearing; lever release spring; lower flange seal gasket; main seat disc; poppet bearing; poppet seat disc; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; outer stem bearing; upper flange seal o-ring
A3219F-302G
A3219F Series
LV4403 Series
A3212A-300
Bearing; cam; gasket; o-rings; seat disc; stem packing
A3217F-80 O-ring flange A3217 Series
A3212-800
See instruction Gasket inlet nipple; seat disc assembly sheets 6542B-50
Gaskets; spring; spring guide; stem and seat disc assembly; upper body
6542B-80
Gaskets; spring; spring guide; stem and seat disc assembly
2503-300N
6542B-300
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
53
REPAIR KITS
ECII Part #
6532,6533,6542, 6543 Series Service Valve
Repair Kits Available
Contents
Instruction Sheet #
19104-50
Complete Multibonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For Multibonnet Only
19104-800
19105
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19105-300
7579-50
Gaskets; seat disc and retainer assembly; spring; upper body
7579-300
7579-80
Gaskets; seat disc and retainer assembly; spring
7579-300A
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7034-300
Check assembly; gasket; o-ring; retaining ring
7141M-300
6579 TA7034P TA7034LP
TA7034-50
7141M
7141M-50
7177
7177-50
Diaphragm; gasket; o-ring; seat disc; washer
7177-300
7188
7188-50
Hydraulic fluid; o-rings; piston; spring; trip latch
7188-300
7193K-50
7193A-51 assembly; adjusting screw; nut; spring; tee
--
7193K-51
Check body and disc assembly; gasket; nipple; tailpiece nipple; slip washer
--
A7505-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A7505-300
7505A-20
Bonnet Assembly
TA7034-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7034-300
A7507-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A7507-300
7507A-20
Bonnet Assembly
TA7507-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7507-300
TA7509-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7509-300
7509B-20
Bonnet Assembly
A7509-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
7509B-20
Bonnet Assembly
7193K-10B
A7505AP A7506AP A7505AP A7506AP A7507AP A7508AP TA7507AP TA7509BP
A7510BP TA7509BP TA7510BP A7511AP A7511FP A7512AP A7512FP A7511AP A7511FP A7512AP A7512FP A7513AP A7514AP A7513AP A7514AP TA7513AP TA7513FP TA7514AP TA7514FP
The VICTOR Propane Equipment Catalog
--
--
-A7509-300 --
TA7509B-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7509B-300
A7511-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A7511-300
7511A-20
Bonnet Assembly
--
TA7511A-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7511-300
A7513-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A7513-300
7513A-20
Bonnet Assembly
A7513-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A5713F-20
Bonnet Assembly
TA7513A-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
-A7513-300 -TA7513A-300
REPAIR KITS
Repair Kits Available by Part Number (cont.)
R EPAIR KITS
54
REPAIR KITS Repair Kits Available by Part Number (cont.) ECII Part # A7515AP A7516AP A7517AP/FP A7518AP/FP TA7515AP TA7516AP A7517AP/FP A7518AP/FP
Repair Kits Available
Contents
A7515-50
Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer
A7515-50
Bonnet Assembly
TA7515A-50
Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer
Instruction Sheet # A7515-300 -TA7515A-300
7547B-50
Gaskets; spring; seat disc and retainer assembly; upper body
7547B-300
7547B-80
Gaskets; spring; seat disc and retainer assembly
7547B-300A
7547DX 7547FX 7547HX
7547B-80
Gaskets; spring; seat disc and retainer assembly
7547B-300A
7550P 7550UP 7551P
7550-15
Bonnet Assembly
--
A7550P A7550PX A7551P
A7550-15
Bonnet Assembly
--
7553T-50
Bonnet; gasket; lever assembly; seat retainer assembly; stem
7553T-300
7553T-80
Gasket, o-ring, seat disc
7553T-301
7547B Series 7547BX Series 7547SX Series
7553T Series
Gaskets; o-ring; roll pin; seat disc; spring; stem assembly
A7553A
A7553A-50
7554LV 7554LAV
7554L-20
Bonnet Assembly
--
7554SV 7554SAV
7554S-20
Bonnet Assembly
--
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19105-300
8475-51A
Body; gaskets; spring; stem and seat disc assembly
8475-300
7556VR, R Series Service Valve
7556VR, R Series Vapor Equalizing Valve
A7553A-300
8475-81A
Gaskets, spring, stem and seat disc assembly
8475-300A
TA7513AP TA7513FP TA7514AP TA7514FP
TA7513A-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7513A-300
7573A Series
7573A-81
Gaskets, spring, seat disc retainer assembly
7573A-300
7579-50
Gaskets; seat disc and retainer assembly; spring; upper body
7579-300
7579-80
Gaskets; seat disc and retainer assembly; spring
7579-300A
7647B Series
7647B-80
Gaskets; seat disc and retainer assembly; spring
7647B-300
A7704 Series A7705 Series A7706 Series
A7705-50
Flange packing; friction washer; gaskets; seat disc
A7705-300
A7707-50
Gaskets; groove pin; jam ring; o-ring; pressure seal rings; seat disc; washers
A7707-300
A7707-75
Bonnet assembly; packing; seat disc and retainer; stem; washers
7579
A7707L A7708BL
--
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
55
REPAIR KITS
ECII Part # A7797
A7853A
Repair Kits Available A7797-50
Gaskets; groove pin; jam ring; o-ring; pressure seal rings; seat disc; washers
A7797-75
Bonnet and lever assembly; stem
A8016DP, A8017 Series A8018DP A8017DH G8475RV G8475RW Filler Valve G8475RV G8475RW Vapor Equalizing Valve
G8475RV G8475RW Service Valve
A7883F-50
Bleeder assembly; bushing; cap; cap screws; filters; gaskets; lock washers; needle valve kit; o-rings; retaining ring; roll pin; screen filter; seal; set screws; springs; stem assembly kit; v-ring, x-seal
7883-300
A7883F-80
Bushing; cylinder cap screws; filters, gaskets; insert; o-rings; retaining ring; seat dsic; v-ring; x-seals
7883-300
A7883F-150
Gaskets; seat disc; x-seal
7883-300
A7883F-50
Bleeder assembly; bushing; cap; cap screws; filters; gaskets; lock washers; needle valve kit; o-rings; retaining ring; roll pin; screen filter; screw; seal; set screws; springs; stem assembly kit; v-ring, x-seal
7883-300
A7884F-80
Bushing; cap screws; filters, gaskets; insert; o-rings; retaining ring; seat dsic; v-ring; x-seals
7883-300
A7884-150
Gaskets; seat disc; x-seal
7883-300
TA7894-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7894-300
7901T-50
Bonnet assembly; gasket; lever
7901-300
7901T-80
Gasket; o-ring; seat retainer assembly
7901-301
A8016B-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A8017BH-20R Bonnet stem and seat disc assembly; gasket 8475-50
Upper body; gaskets; seat disc and retainer assembly; spring
8475-80
Gasket; seal; seat disc and retainer assembly; spring
A8016B-300 A8017BH-300 8475-300F
8475-51A
Body; gaskets; spring; stem and seat disc assembly
8475-81A
Gaskets, spring, stem and seat disc assembly
8475-300A
19104-50
Complete MultiBonnet Aseembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; Stem and o-ring assembly; handwheel; self tapping screw
19100-300B
3165C
8542G/AA8542 Series
8540-50
Bleeder valve assemblies; packing; gland; set screw; washer; gasket; key
8547W/VWN
8547-2
Bonnet; o-ring and stem assembly
The VICTOR Propane Equipment Catalog
-A7853A-300
G8475RV G8475RW Fixed Liquid Level Gauge
8555D/R Series Mfg’d 10/90 or before
A7797-300
A7853A-50
A7884FK
7901 Series
Instruction Sheet #
Block v-packing; gaskets; o-rings - piston, stem and yoke; roll pin; seat disc; seat disc retainer assembly; springs
A7883FK
TA7894P
Contents
Fixed liquid evel gauge valve
6542B-50
Gaskets; spring; spring guide; stem and seat disc assembly; upper body
6542B-80
Gaskets; spring; spring guide; stem and seat assembly
8475-300
--
8540-300 -6542B-300
REPAIR KITS
Repair Kits Available by Part Number (cont.)
R EPAIR KITS
56
REPAIR KITS Repair Kits Available by Part Number (cont.) ECII Part #
Repair Kits Available
Contents
8555D/R Series Mfg’d after 10/90 Filler valve
8555-50
Gaskets; spring; spring guide; stem and seat disc assembly; upper body
8555-80
Gaskets; spring; spring guide; stem and seat disc assembly
8555DL
19100-50B
8555D Series Service Valve
8555R Series Service Valve A/AA 8560 Series A/AA 8570 Series 8593A/AR Filler Valve 8593A/AR Vapor Equalizing Valve
8593A/AR Service valve
9101C, D, H, R, P, Y Series Service Valve
9103C, D Series Service Valve
9103T9F
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
Instruction Sheet # 8555-300
19100-300B
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19100-300B
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
8560-50
Bleeder valve assemblies; seat ring assemblies; pressure seal rings; packing gland; jam ring; washer; gasket
7564-300
8475-50
Gaskets; seat disc and retainer assembly; spring; upper body
8475-80
Gasket; seal; seat disc and retainer assembly; spring
8475-300F
8475-51A
Body; gaskets; spring; stem and seat disc assembly
8475-81A
Gaskets; spring; stem and seat disc assembly
8475-300A
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19100-300B
8475-300
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19100-300B
19101-50
Bonnet; stem and o-ring assembly; handwheel (small); self tapping screw
19101-300
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19100-300B
19105-50
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19105-300
903-50
Bonnet; stem and seat disc assembly; large handwheel; self tapping screw
903-51
Bonnet; stem and seat disc assembly; small handwheel; self tapping screw
9106CO
903-300
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REPAIR KITS
57
ECII Part #
Repair Kits Available
9107K8A, K2A
19100-50B
9300Y/R
Contents Bonnet; stem and seat disc assembly; handwheel; self tapping screw
Instruction Sheet # 19100-300B
19104-50
Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw
19104-300
19104-80
Upper packing with seal rings - For MultiBonnet Only
19104-800
19100-50B
Bonnet; stem and o-ring assembly; handwheel; self tapping screw
19100-300B
Repair Kits Available for Obsolete Part Numbers ECII Part #
Repair Kits Available
Contents
1470 LV, 1480V Series
May be replaced with G8475RV Series
1470W, 1480W Series
May be replaced with G8475W Series
1470, 1480 Series Service Valves
Instruction Sheet #
3100-80A
Bonnet; Diaphragm assembly; stem
3100-80B
Diaphragm assembly; washer
3100-81K
Conversion kit; bonnet and stem assembly
3100K-300 1475-300F
1470, 1480 Series Service Valve
1475-80
Seat disc and stem assembly; spring; washer
1470, 1480 Series Vapor Equalizing Valve
2418-51
Body, gasket; seat disc and stem assembly; spring; washer
AA1582E Series
AA1582E-50
AA1584E Series AA1586E Series
Diaphragm and yoke assembly (standard); screen; small spring; stem and seat disc retainer assembly; tetraseals
3100-301
AA1582E-300 AA1584E-300 AA158E-300
2180 Series
Replace with 8555D/R for cylinders with up to 200# propane capacity, for containers with capacities up to 400# use 6533A/R
2403 Series
See Instruction Gasket, inlet nipple, seat disc assembly Sheet
2418 2418, 2550 Vapor Equalizing Valve
Replace with G8475RV 2418-51
Body; gasket; seat disc and stem assembly; spring; washer
2465L,2486
No repair parts available - replace with G8475RV Series
2503 Series
See Instruction Gasket, inlet nipple, seat disc assembly Sheet
2250 2250 Vapor Equalizing valve 2555 Series 2577 2577 Series
The VICTOR Propane Equipment Catalog
2503-300N
Replace with G8475RV Series 2418-51
Body, gasket; seat disc and stem assembly; spring; washer
Replace with 6532, 6533, 6542, 6543 Series No repair parts or replacement valve available Replace with 6532, 6533, 6542, 6543 Series
2503-300N
REPAIR KITS
Repair Kits Available by Part Number (cont.)
R EPAIR KITS
58
REPAIR KITS Repair Kits Available for Obsolete Part Numbers (cont.) ECII Part #
Repair Kits Available
Contents
2580, 2581
No repair parts or replacement valve available replace with 8555D/8555R Series
2593, 2594
Replace with 8593AR16.0
2593K, 2594K
No replacement available
2593/K, 2594/K Service Valve
3100-80A
Bonnet; Diaphragm assembly; stem
3100-80B
Diaphragm assembly; washer
3100-81K
Conversion kit; bonnet and stem assembly
3100K-300 1475-300F
2593/K, 2594/K Filler Valve
1475-80
Seat disc and stem assembly; spring; washer
2593/K, 2594/K Vapor Equalizing Valve
2418-51
Body; gasket; seat disc and stem assembly; spring; washer
3103 6477A Vapor Equalizing Valve
8475-51A
Body; gaskets; seat disc and retainer assembly; spring; stem
5475-81A
Gaskets; seat disc and retainer assembly; spring; stem
903-50
Bonnet assembly; large handwheel; self tapping screw
903-51
Bonnet assembly; large handwheel; self tapping screw
6532, 6533, 6542, 6543 Filler Valve
6542B
Body, gasket; seat disc assembly; spring; stem
6542B-80
Gaskets; seat disc assembly; spring; stem
A7016A
A7505-50
Gaskets; jam ring, o-ring; pressure seal rings; seat disc; washer
8100-50
A7762B, A7727B, A7728B
AA1582F-50
7747 Series
7547B-50
8100 Series
8100-50
8103 Series
G8475 Filler Valves
G8475 Vapor Equalizing Valve 8477 8477 Mfg’d before 1962 Service Valve 8477 Mfg’d before 1962 Filler Valve
903-300
6542B-300 A7505-300
Replace with 8555D/R Series
7556 Mfg’s before 1962
G8475 Mfg’d before 1962
3100-301
Replace with 9103 for cylinders 100 lb. or less
6532D, 6533D, 6542D, 6543D Service Valve
7555
Instruction Sheet #
Bonnet assembly; handwheel Gaskets; flange packing; friction washer; seat disc Gaskets; seat disc and retainer assembly; spring; upper body Bonnet; o-ring and stem assembly; handwheel; self tapping tee
8100-300 A7726B-300 7547B-300 8100-300
No repair kits available - replace with 9103 Series 8100-50
Bonnet assembly; handwheel
8475-50
Body, gaskets; seat disc and retainer assembly; spring
8475-50
Gaskets; seat disc and retainer assembly; spring
8475-51A
Body, gaskets; seat disc and retainer assembly; spring; stem
8475-81A
Gaskets; seat disc and retainer assembly; spring; stem
8100-300
8475-300F
8475-300 8475-300A
Replace with G8475RV 8100-50
Bonnet assembly; handwheel
8475-50
Body; gaskets; seat disc and retainer assembly; spring
8475-80
Gasket; seat disc and stem assembly; spring
8100-300
8475-300F
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
REPAIR KITS
59
ECII Part # 8477 Mfg’d before 1962 Vapor Equalizing Valve 8484 Mfg’d before 1962 Service Valve 8484A 8484A Service Valve 8484/A Vapor Equalizing Valve 8555 Series Mfg’d before 1962 8555S Series Service Valve 8555S Series Filler Valve 8593/K Filler Valve
8593/K Vapor Equalizing Valve 8594
Repair Kits Available
Contents
Instruction Sheet #
8475-51A
Body, gaskets; seat disc and retainer assembly; spring; stem
8475-300
8475-81A
Gaskets; seat disc and retainer assembly; spring; stem
8100-50
19100-50B
Bonnet assembly; handwheel
8475-51A
Body; gaskets; seat disc and retainer assembly; spring; stem
8475-81A
Gaskets; seat disc and retainer assembly; spring; stem
19100-300B 8475-300 8475-300A
No repair parts available - replace with 8555D/R Series 903-50
Bonnet assembly; large handwheel; self tapping screw
903-51
Bonnet assembly; small handwheel; self tapping screw
6542B-50
Body, gaskets; seat disc assembly; spring; stem
6542B-80
Gaskets; seat disc assembly; spring; stem
8475-50
Body; gaskets; seat disc and retainer assembly; spring
8475-80
Gaskets; seat disc and retainer assembly; spring
8475-51A
Body; gaskets; seat disc and retainer assembly; spring; stem
8475-81A
Gaskets; seat disc and retainer assembly; spring; stem
903-300
6542B-300
8475-300F
8475-300 8475-300A
Replace with 8593AR16.0 8100-50
8594/K Mfg’d before 1962 Service Valve
19100-50B
Bonnet assembly; handwheel Bonnet and stem assembly; handwheel; self tapping screw
8475-50
Body, gaskets; seat disc and retainer assembly; spring
8475-80
Gaskets; seat disc and retainer assembly; spring
8475-51A
Body, gaskets; seat disc and retainer assembly; spring; stem
8475-81A
Gaskets; seat disc and retainer assembly; spring; stem
8594/K
The VICTOR Propane Equipment Catalog
8100-300
No replacement valves available
8594/K Mfg’d before 1962 Service Valve
8594/K
Bonnet assembly; handwheel
8475-300A
8100-300
19100-300B
8475-300F
8475-300 8475-300A
REPAIR KITS
Repair Kits Available for Obsolete Part Numbers (cont.)
METERS
60
METERS Single Joint Residential Gas Meter R-275 275 SCFH These class 250 residential meters are an improved revision of the R-200 family. The latest design concepts and modern engineering materials have been combined to provide a lighter weight, easier to handle, more durable meter which requires less maintenance and offers greater life expectancy. All models stocked are temperature compensated.
Specifications
Kits Available
Capacity-SCFH 1/2" W.C. Diff. Meter Model R-275-20 Lt. R-275-30 Lt. R415-45Lt S-275
But.
Prop.
Max. W.P. PSI
Approx. Shpg. Wt Lbs.
150
175
5-10
14
225 150
260 175
10-125 5-10
21 14
Meter Connections Available 20 Lt. 30 Lt. 45 Lt. 3/4" NPT
with swivels, nuts & gaskets included Webb# 244671 244675 244672 181926
Model # R275-20LTK R275-30LTK R415-45LTK
Webb# 181925 244642 181919
Intermediate and Large Capacity Diaphragm Type Gas Meters 10,000 Meter The rugged 10,000 meter, with “O” ring seal, is the largest of the Equimeter line of single joint aluminum gas meters. This lightweight, large capacity meter, made of aluminum alloy, has a working pressure of 100 psi, yet weighs only 323 pounds — about one-third the weight of comparable iron meters. Its rigid construction and light weight make it the perfect meter for commercial and industrial operations requiring large volume loads at high pressure.
3000 Meter The sturdy design, internally and externally, of the Equimeter 3000 meter makes it ideal for commercial and industrial operations where large volume loads at high pressure, up to 100 psi, are necessary. Single joint construction and “O” ring type gasket insure a positive seal against leakage. Aluminum alloy construction of the cover, body, and valve plate accounts for its lightweight durability and economy in shipping costs. Compact, 281/4” x 16” wide, and weighing approximately 100 pounds, the 3000 meter eliminates many of the service and installation problems encountered with the heavier cast iron meters.
750 Meters and 1600 Meters The 750 meters, like all Equimeter single joint lightweight meters, are extremely versatile because repair and space problems are reduced to a minimum. Due to advanced design and engineering features, both of these meters have all of the inherent simplicity and accuracy of the reputable Equimeter single joint meters. The 1600 is constructed of sturdy aluminum alloy castings. It has an “O” ring seal and is especially suited to small industrial and commercial operations where large capacities at high pressure are needed. Guide wires are utilized in the 750 to provide the smoothest possible diaphragm motion and to assure proof stability and long meter life. To correct the actual cubic foot index reading to base (standard) conditions, the pressure multiplier is calculated by adding the line (gauge) pressure to the average atmospheric (psia) then dividing by the base pressure (psia). Eg: Pressure Multipler = (10 psig + 14.48 psia) ÷14.73 psia = 1.662
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 www.victormfg.com
METERS
61
5000 Meter The great weight reduction over previous cast iron models, made possible by the use of aluminum alloy for the cover, body, and valve plate, results in substantial savings in shipping costs as well as greater ease in handling. To prevent leakage between the body and cover, the 5000 meter has an “O” ring seal. Its compact design and light weight make this meter an ideal replacement for large tin meters still in service, and for downtown basement installations where a large capacity, yet easy-to-handle, meter is required.
1000 Meter The 1000 meter, newest member of the single joint line of meters, was engineered for intermediate size loads on commercial and industrial services. It was designed and built specifically for 1000 cfh loads— not an alteration or redesign of an existing meter. The low speed (1.6 REV/CF) of the 1000 meter ensures proof stability and log service life with minimum maintenance. This meter, as well as all others described on this page, incorporate such recognized Equimeter features as single joint and low friction valves. The 1000 meter, as well as all the other members of the single joint family, makes use of the modern engineering plastic (Lexan) for its index box as standard equipment.
Natural Gas Capacities
Natural Gas Capacities SCFH of 0.6 Sp. Gr. Gas at Elevated Pressures
Meter Model
Capacity Rating @ 1/2" w.c. Differential
Capacity Rating @ 2" w.c. Differential
Webb#
750*
750 CFH
1600 CFH
181924
1600
800
1600
1000*
1000
2200
181911
3000
1450
3000
247443
5000
2500
5000
10000
5000
10000
Gauge Pressure (PSIG)
Differential
750
1600
1000
3000
5000
10,000
2" w.c.
1,600
1,600
2,200
3,000
5,000
10,000
Max. Allow
1,600
1,600
2,200
3,000
5,000
10,000
2" w.c.
1,840
1,840
2,530
3,450
5,750
11,500
247444
Max. Allow
2,070
2,070
2,840
3,880
6,450
12,900
247445
2" w.c.
2,080
2,080
2,860
3,900
6,500
13,000
Max. Allow
2,480
2,480
3,420
4,660
7,760
15,550
2" w.c.
2,320
2,320
3,190
4,350
7,250
14,500
Max. Allow
2,840
2,840
3,960
5,400
9,000
18,000
2" w.c.
2,480
2,480
3,410
4,650
7,750
15,500
Max. Allow
3,230
3,230
4,440
5,820
10,100 20,200
0.25 5
10
* In Stock
Propane 15 Gauge Pressure (PSIG) 0.25
Differential
1600
1000
3000
5000
10,000
2" w.c.
990
990
1,360
1,860
3,100
6,200
Max. Allow
1,340
1,340
1,850
2,520
4,200
8,400
2" w.c.
1,120
1,120
1,540
2,100
3,500
7,000
Max. Allow
1,630
1,630
2,240
3,060
5,100
10,200
5
10
750
2" w.c.
1,260
1,260
1,740
2,370
3,950
7,900
Max. Allow
1,920
1,920
2,640
3,600
6,000
12,000
20
25
40
50
Specifications Capacity Capacity @ 1/2" w.c. @ 2" w.c. diff. of 0.6 diff. of 0.6 Sp. Gr. Gas Sp. Gr. Gas Standard CFH CFH Connections
70
2" w.c.
2,640
3,630
4,950
8,250
Max. Allow
3,570
4,900
6,700
11,100 22,300
2" w.c.
3,120
5,850
9,750
Max. Allow
4,450
8,700
13,900 27,800
2" w.c.
3,360
6,300
10,500 21,000
5,000
9,370
15,600 31,200
2" w.c.
3,840
7,200
12,000 24,000
Max. Allow
5,960
11,200
18,700 37,400
2" w.c.
4,480
8,400
14,000 28,000
Max. Allow
7,170
13,400 22,400 44,800
Meter Model 750
20
750
1600
45 Lt.
Kits Available
1000
25
1000
2200
45 Lt.
with swivels, nuts & gaskets included
3000 wo/flanges*
100
1450
3000
3" - 8" PT
5000 wo/flanges*
100
2500
5000
4" - 8" PT
10000 wo/flanges*
100
5000
10000
4" - 8" PT
* Special Order
The VICTOR Propane Equipment Catalog
Model # 750K 1000K
19,500
Max. Allow
Maximum Working Pressure (PSIG)
100
16,500
Connection With 45LT conn.
Webb# 244673 244674
METERS
Intermediate and Large Capacity Diaphragm Type Gas Meters (cont.)
METER ACCESSORIES
62
METER ACCESSORIES
How to identify Parts
MATERIAL SPECIFICATIONS Body/End Piece
Cast Iron per ASTM A 126 Class B
Plug/Cap Stem
Cast Brass – ASTM B 584/Alloy 83600 or Alloy 84400
Brass Ball
CDA3600
Brass Nuts & Washers (Plug Valve) 3002
ASTM B 584/Alloy B83600 or Alloy 84400 or MPIF Std. 35 CZ
O-Rings/Torque Seals
Buna-N (Nitrile) or Neoprene rubber
Port Seals (Ball Valve)
Neoprene Rubber
Union Tailpieces
Zinc plated yellow dichromate finished steel
Insulated Union Tailpieces
Zytel nylon insulation
Union Nut
Malleable Iron per ASTM A 47 or Ductile iron per ASTM
High Pressure Meter Valves — Plug Style
High Pressure Meter Valves — Ball Style
Tamperproof • 175 PSIG
Tamperproof • 175 PSIG • Patented Flat Head • Lockwing
FLAT HEAD • LOCKWING
560B Black Iron Body 3/4”, 1”, 11/4”, 11/2”, 2” MFR# DESC. WEBB# AYM560B-8 1/2” 184925
560B Black Iron Body 3/4”, 1”, 11/4” MFR# DESC. WEBB# AYM560B-12 3/4” 184924
760B
Special Order
6276B MFR# AYM6276B-34
3/4”
DESC.WEBB# 216737
AYM6276B-1
1”
216738
AYM6276B-114 11/4” 216739
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 www.victormfg.com
METER ACCESSORIES Accessories
Horizontal Inlet and Outlet 6610 Series — 6” Centerline
Meter Nuts — 30LT
6610-B
6610-F
Meter Nuts are used to connect straight and/or offset swivel gas fittings to the gas meter. Manufactured per ANSI B109.1.
Integral FIP
Meter Plugs — 20LT
Female Insulated flat gasket union
MFR# AYM6610-F-1X1X1
DESC. WEBB# 1” 250082
A 1
B 1
C 1
Cast Iron Meter Bars w/Integral Swivels Horizontal Inlet and Outlet 6620 Series — 6” Centerline
6620-B
Integral FIP
A 1
6620-F
B 1
C 20LT
Female Insulated flat gasket union
Cast Iron Meter Bar Rear Center Horizontal Inlet and Vertical Outlet (Direct center/Horizontal inlet) 6722 Series — 6” Centerline For multiple meter manifold applications
6722-F
Female Insulated
MFR# AYM6722-C-C
DESC. Swivels
WEBB# 250083
A 1
The VICTOR Propane Equipment Catalog
B 1
C 20LT
Meter Plugs are used to prevent the unintentional flow of gas from meter sets without meters attached. They also prevent insects and other foreign matter from entering the gas piping.
Gasket for Meter Swivels — 20LT & 30LT Gaskets are used to seal malleable iron offset or straight fittings on the face of the gas meter when tightening the swivel nut on meter thread of meter nut plug. These rubber gaskets made of Buna-N or neoprene are resistant to the action of natural and manufactured gases. The inside diameter is intended to lightly grip the pilot O.D. of the fitting to minimize problems during assembly of the swivel nut to the meter
6300 Series • 3 Part Union 3/4” or 1” 3 Part Unions are designed to prevent electrolysis or other corrosive action in 3/4” or 1” gas service lines. They are resistant to most chemical substances, including gas, water and petroleum oils at normal temperatures. Meets ANSI B1.20.1 standards. • 175 PSIG • All have female NPT headpiece MODEL NUMBER 6301 Female Insulated flat gasket union MFR# EQU0016115402000
DESC. 20 LT Washer
WEBB# 244635
EQU0016115503000
30 LT Washer
244638
EQU0016215502000
45 LT Washer
244643
EQU0014116600000
20 LT Black Nut
244636
EQU0014116707000
30 LT Black Swivel Nut 244639
EQU0014116800000
45 LT Black Nut
244644
METER ACCESSORIES
Cast Iron Meter Bars
63
CYLINDERS Steel Cylinders 9.125 in./ 231.8 mm
9.125 in./ 231.8 mm
4.25 lb. to 60 lb. LPG Cylinders
6.5 in./165.1 mm
16.625 in./ 422.3 mm
11.625 in./ 295.3 mm
6.5 in./165.1 mm
4.25 lb.
12.125 in./ 308 mm
12.125 in./ 308 mm
11 lb.
17.625 in./ 447.6 mm
23.687 in./601.6 mm
6.5 in./165.1 mm
6.5 in./165.1 mm
20 lb.
Worthington’s steel portable cylinders in eight sizes for commercial, industrial, recreational and home applications. These cylinders are manufactured to Department of Transportation (DOT) 4BA-240 specifications. PART NUMBER VALVE G/T4.5-OPD Type 1 w/OPD
SIZE 4.5 lbs
G/T11-OPD
Type 1 w/OPD
11.0 lbs 194228
G/T20-OPD
Type1 w/OPD
20 lbs
190980
G/T20-QD
Type2 w/OPD
20 lbs
201194
G/T30-OPD
Type1 w/OPD
30 lbs
190983
G/T40-OPD
Type1 w/OPD
40 lbs
194229
G/T43
POL Valve
43.5 lbs 223351
G/T60
POL Valve
60 lbs
12.125 in./ 308 mm
12.125 in./ 308 mm
6.5 in./165.1 mm
WEBB# 194227
Steel Cylinders
185251
Size
4.25 lb.
11 lb.
20 lb.
30 lb.
40 lb.
43.5 lb.
60 lb.
LPG Capacity
1.0 gal. 3.8 liters
2.6 gal. 9.8 liters
4.7 gal. 17.9 liters
7.1 gal. 26.8 liters
9.4 gal. 35.7 liters
10.3 gal. 38.8 liters
14.2 gal. 53.5 liters
Water Capacity
12.0 lb. 5.4 kg
26.2 lb. 11.9 kg
47.6 lb. 21.6 kg
71.5 lb. 32.4 kg
95.2 lb. 43.2 kg
103.6 lb. 47.0 kg
142.9 lb. 64.8 kg
Tare Weight
11.9 lb. 5.4 kg
13.8 lb. 6.3 kg
17.0 lb. 7.7 kg
25.4 lb. 11.5 kg
33.6 lb. 15.2 kg
34.4 lb. 15.6 kg
48.0 lb. 21.8 kg
Collar Height
4.0 in. 101.6 mm
4.0 in. 101.6 mm
4.0 in. 4.0 in. 4.0 in. 5.1 in. 5.1 in. 101.6 mm 101.6 mm 101.6 mm 129.5 mm 130.2 mm
Footring Dia. o/s
9.1 in. 231.2 mm
7.8 in. 198.4 mm
7.8 in. 7.8 in. 7.8 in. 12.0 in. 12.0 in. 198.4 mm 198.4 mm 198.4 mm 304.8 mm 304.8 mm
30 lb.
6.5 in./165.1 mm
40 lb. 12.25 in./ 311 mm
43.5 lb.
6.5 in./165.1 mm
60 lb.
32.5 in./825.5 mm
29.250 in./743 mm
Aluminum Cylinders
42.2 in./1071 mm
CYLINDERS
64
6 lb. to 40 lb. LPG Cylinders Attractive, corrosion-resistant aluminum makes the ideal cylinder for home and recreational use. These cylinders are lightweight and easy to handle, but durable for the most demanding applications. The exterior finish is smooth and sleek. The interior is clean, dry and free of foreign matter. All aluminum cylinders meet DOT-4E specifications. PART NUMBER VALVE G/TA6-OPD Type 1 w/OPD
SIZE 6 lbs
WEBB#
G/TA10-OPD
Type 1 w/OPD
10 lbs
G/TA20-OPD
Type1 w/OPD
20 lbs
185252
G/TA30-OPD
Type1 w/OPD
30 lbs
185253
G/TA40-OPD
Type1 w/OPD
40 lbs
Size
6 lb.
10 lb.
20 lb.
30 lb.
40 lb.
LPG Capacity
1.4 gal. 5.4 liters
2.4 gal. 8.9 liters
4.7 gal. 17.9 liters
7.1 gal. 26.8 liters
9.4 gal. 35.7 liters
Water Capacity
15.0 lb. 6.8 kg
23.8 lb. 10.8 kg
47.6 lb. 21.6 kg
71.5 lb. 32.4 kg
95.2 lb. 43.2 kg
Tare Weight
8.0 lb. 3.6 kg
10.1 lb. 4.6 kg
14.1 lb. 6.4 kg
18.0 lb. 8.2 kg
20.9 lb. 9.5 kg
Collar Height
6.5 in. 165.1mm.
5.5 in. 139.7mm.
5.5 in. 139.7mm.
5.5 in. 139.7mm.
5.5 in. 139.7mm.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
CYLINDERS
65 CYLINDERS
Steel Motor Fuel Cylinders
26.75 in./679.45 mm
33.5 lb. Forklift Cylinders Steel forklift cylinders feature two-piece construction with one horizontal weld for a stronger, better looking cylinder with less chance of leakage. The rugged, damage- resistant footring minimizes future repairs. Interior cylinder walls are smooth, dry and free of foreign matter. PART NUMBER DESCRIPTION SIZE WEBB# G/T33MF No Filler Valve 331/2 lbs. 185239 G/T33MFA
Motor Fuel Cylinders
13/4 Filler Valve 331/2 lbs. 185240
33.5 lb.
Aluminum Motor Fuel Cylinders 12.5 in./317.5 mm
33.5 lb Forklift Cylinders
A: Universal float gauge B. Liquid service valve C. Safety relief valve D. Fixed liquid level E. Vapor service (plugged) F. Liquid fill port (plugged)
Worthington combines the highest standards of manufacturing quality with the light weight and durability of aluminum to provide you lift truck cylinders that readily return your investment through savings in handling, repairs, maintenance, and customer preference. Manufactured in accordance with DOT-4E240 specifications. PART NUMBER DESCRIPTION G/TA33MF Aluminum, No Filler Valve G/TA33MFA
Motor Fuel Applications
The VICTOR Propane Equipment Catalog
SIZE WEBB# 331/2 lbs. 185254
Aluminum, 13/4 M. ACME Filler Valve 331/2 lbs. 185255
CYLINDERS DOT/ASME LPG Cylinders 14.625 in./371.5 mm
100, 200, & 420 lb. Cylinders • Exceptional quality and service. Manufactured to DOT, Transport Canada or ASME specifications. • All gas containment welds are automatic MIG/submerged arc welds. • All tanks are 100% leak tested before and after mechanical valve installation. • All tanks pretreated with chemical wash to improve corrosion resistance and powder coating adhesion. • Worthington’s manufacturing process minimizes odorant fade and maximizes paint coating quality. • Worthington’s Durabond 2000 powder paint finish is the highest quality and most durable powder coating available in the industry. • Tank interiors are clean, dry, and free of foreign matter. • Can be used in multiple cylinder installations. • Now with the industry’s largest diameter “user Friendly” collar for more work room during filling. • On-time delivery and competitive pricing. Readily available during peak season to service new business.
48.5 in./1232 mm
6.5 in./165.1 mm
100 lb. Description and Size of 200# L.P.G. Cylinder Openings A: Multi-Valve (3/4”) NPT B: NPT Float Gauge (!”) NPT
DOT Cylinders 24 in./610 mm
39.7 in./1008 mm
16 in./407 mm
200 lb.
30 in./762 mm
16 in./407 mm
51.7 in./1313.2 mm
CYLINDERS
66
PART NUMBER VALVE G/T100 POL w/1090
SIZE COLOR 100 lbs. Gray
WEBB# 185223
G/T100M
Multivalve
100 lbs. Gray
185226
G/T100MW
Multivalve
100 lbs. White
194259
G/T200
Multivalve
200 lbs. White
185229
G/T200G
Multivalve
200 lbs. Gray
192637
G/T100M
Multivalve
200 lbs. Gray
185226
G/T420
Multivalve POL 420 lbs. White
185243
G/T420G
Multivalve POL 420 lbs. Gray
192638
ASME Cylinders PART NUMBER VALVE G/T200ASME Multivalve
SIZE COLOR 200 lbs. White
WEBB# 190984
G/T200ASMEG Multivalve
200 lbs. Gray
193312
G/T420ASME
Multivalve POL 420 lbs. White
G/T420ASMEG Multivalve POL 420 lbs. Gray
185244 193311
420 lb. Description and Size of 420# L.P.G. Cylinder Openings A: Safety Relief Valve (1”) NPT B: Fill Valve (3/4”) NPT C: NPT Float Gauge (1”) NPT D: Vapor Service Valve (3/4”) NPT
Size
100 lb.
200 lb.
420 lb.
LPG Capacity
23.6 gal. 89.3 liters
47.2 gal. 178.5 liters
99.1 gal. 374.9 liters
Water Capacity
239.0 lb. 108.4 kg
474 lb. 215.0 kg
1000 lb. 453.6 kg
Tare Weight
71.0 lb. 32.2 kg
158.0 lb. 71.7 kg
272.0 lb. 123.4 kg
Collar Height
5.1 in. 130.2 mm.
6.6 in. 167.6 mm.
6.6 in. 167.6 mm.
Footring Dia. o/s
14.5 in. 368.3 mm.
19.0 in 482.6 mm
22.0 in 558.8 mm
How to Order a Truckload 11 bundles make up a truckload. Special colors, or plastic mesh protective coatings are available upon request. There is a quantity of 9-420’s in a bundle, and 16-200’s in a bundle. You must specify DOT or ASME style tanks at time of order. Minimum order of 3 bundles is considered a partial truckload. No more than 3 different stops per truckload within a 150 mile radius.
Open Collar (for 100# Cylinders) MFR # DESC. WEBB# PIGME350A Multi-Valve 186562
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
67
CYLINDERS The withdrawal of propane vapor from a vessel lowers the contained pressure. This causes the liquid to “boil” in an effort to restore the pressure by generating vapor to replace that which was withdrawn. The required “latent heat of vaporization” is surrendered by the liquid and causes the temperature of the liquid to drop as a result of the heat so expended. The heat lost due to the vaporization of the liquid is replaced by the heat in the air surrounding the container. This heat is transferred from the air through the metal surface of the vessel into the liquid. The area of the vessel in contact with vapor is not considered because the heat absorbed by the vapor is negligible. The surface area of the vessel that is bathed in liquid is known as the “wetted surface”. The greater this wetted surface, or in other words the greater the amount of liquid in the vessel, the greater the vaporization capacity of the system. A larger container would have a larger wetted surface area and therefore would have greater vaporization capacity. If the liquid in the vessel receives heat for vaporization from the outside air, the higher the outside air temperature, the higher the vaporization rate of the system. How all this affects the vaporization rate of a 100 lbs. cylinder is shown in a following section (return to contents and see 100# DOT cylinders. You will note that the worst conditions for vaporization rates are when the container has a small amount of liquid in it and the outside air temperature is low. Simple formulae for determining the proper number of DOT cylinders and proper size of ASME storage containers for various loads where temperatures may reach 0 ° F will be found in the sections on 100# DOT Cylinders and ASME Storage tanks respectively
Determining Total Load In order to properly size the storage container, regulator and piping, the total BTU load must be determined. The total load is the sum of al gas usage in the installation. It is arrived at by adding up the BTU input of all appliances in the installation. The BTU input may be obtained from the nameplate on the appliance or from the manufacturers literature. Future appliances which may be installed should also be considered when planning the initial installation to eliminate the need for a later revision of the piping and storage facilities. Where it may be more desirable to have ratings expressed in CFH, divide the total BTU load by 2516 for CFH of propane.
The VICTOR Propane Equipment Catalog
Approximate BTU Input for Some Common Appliances APPLIANCE Range, free standing, domestic
APPROX INPUT (BTU PER HOUR) 65,000
Built-in Oven or Broiler, domestic
25,000
Built-in Top Unit, domestic
40,000
Water Heater, Quick Recovery, Automatic Storage 30 Gallon Tank 30,000 40 Gallon Tank 38,000 50 Gallon tank 50,000 Water Heater, Automatic Instantaneous 2 gal/minute 142,800 4 gal/minute 285,000 6 gal/minute 482,000 Refrigerator
3,000
Clothes Dryer, domestic
35,000
Incinerator, domestic
32,000
100# DOT Cylinders “Rule of Thumb” Guide for Installing 100 Lb. Cylinders For continuous draws where temperatures may reach zero F. Assume the vaporization rate of a 100 lb. cylinder as approximately 50,000 BTU per hour. Number of Cylinders per side = Total load in BTU’s 50,000 Example: Assume total load = 200,000 BTU/hr. Cylinders per side = 200,000 = 4 cylinders per side. 50,000
Vaporization Rate 100 lb. Propane Cylinders (approximate) Lbs. of Propane in Cyl
Maximum Continuous Draw in BTU Per Hour at Various Temperatures in Degrees F. 0
20
40
60
70
100
113,000
167,000
214,000
277,000
300,000
90
104,000
152,000
200,000
247,000
277,000
80
94,000
137,000
180,000
214,000
236,000
70
83,000
122,000
160,000
199,000
214,000
60
75,000
109,000
140,000
176,000
192,000
50
64,000
94,000
125,000
154,000
167,000
40
55,000
79,000
105,000
131,000
141,000
30
45,000
66,000
85,000
107,000
118,000
20
36,000
51,000
68,000
83,000
92,000
10
28,000
38,000
49,000
60,000
66,000
This chart shows the vaporization rate of containers in terms of the temperature of the liquid and the wet surface area of the container. When the temperature is lower or if the container has less liquid in it, the vaporization rate of the container is a lower value.
CYLINDERS
Propane Storage Vessels
68
CYLINDER ACCESSORIES
CYLINDER ACCESSORIES
“Wall Hugger” Cylinder Vise Big Performance, Small Profile The unique design of this powerful cylinder vise allows you to replace cylinder valves quickly and easily, yet does not require a lot of valuable dock space. The “Wall Hugger” actually uses less floor space than this catalog! PART # AMDCV-1
DESCRIPTION WEBB# Cylinder Vise 202780
Pump Station Enclosure Protect Your Equipment • Double doors, Heavy duty load bearing floor • Adjustable top shelf • “Duty to Warn” decals • Tamper resistant hardware “Wall Hugger” Cylinder Vise
PART # PSEO-302L-D PSEO-303L-D
DESCRIPTION 68” x 44” x 30” 68” x 44” x 39”
WEBB# 184880
Pump Station Enclosure
“Little Giant” Stationary Tank Inverter Will lift and invert all cylinders from a single (or double) 100# thru a full 420#. Indexes to 90°, 180° or 45° to facilitate valve relacement, evacuation and bottom maintenance. Doubles as a vice. Small 3’ x 4’ base saves dock space. PART # AMDCV-1
“Little Giant” Tank Inverter
DESCRIPTION Tank Inverter
WEBB# 184881
20 Pound Cylinder Cabinets PART # AMD29LB6 AMD20LB12-302M-S
DESCRIPTION WEBB# 6 capacity 202790 12 capacity, 3 wide 202792
Fork Lift Cabinets PART # AMDFTCH12-302L-S AMDFTCV06-302M-S AMDFTCH16-402L-D
DESCRIPTION 12 capacity, 3 wide, horizontal 12 capacity, 3 wide, vertical 16 capacity, 4 wide, horizontal
WEBB# 202791 202793 202793
Portable Beam Utility Scale Model 1124 Applications A general purpose, 1000 lb., portable scale utilizing a mechanical beam for industrial and commercial use. MFR# FBS1124
DESCRIPTION Portable Beam Scale
WEBB# 181957
Features & Benefits • 1000 lb. capacity • 17.75” x 23.5” platform • Rugged, cast iron base, lever system and platform are designed for durability • Easy to read, brass beam insert will not fade in direct sunlight • Easy to maneuver with built-in wheels • Conforms to NTEP standards for weighing food, commodities, propane and more To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
CYLINDER ACCESSORIES Ashcroft Pressure Gauges
The Best Way to Install OPD Cylinder Valves
MFR# DESCRIPTION WEBB# 21/2” Dial, 1/4” Brass Lower Mount, ABS Case ASH102990 0-15 PSI 36483
The TTW-3 is a totally new concept in valve wrenches. It quickens installation and removal of QC cylinder valves from DOT containers. The wrench works on all Style 1 (QC) valves, particularly the fixed handwheel OPD’s that are mandated by the DOT for all 5 lb. to 40 lb. cylinders. The TTW-3 mates to the cylinder valve QC thread, rather than the POL thread, reducing the possibility of valve deformation when removing or installing. The wrench seats flush against the valve face, distributing torque across a wider area. And the compact TTW-3 fits under the handwheel valve and allows rotation inside the cylinder collar, simplifying the removal and installation procedure. The TTW-3 also incorporates a bleed orifice safety feature that will indicate any pressure remaining in the cylinder before removing the valve by simply opening the valve slightly prior to loosening. The wrench is made from tough, durable alloy and forged steel components. This long-lasting construction resists corrosion and distortion. MODEL# VCTTTW-3
WEBB# 192938
0-30 PSI
36484
ASH001941
0-60 PSI
36485
ASH001958
0-100 PSI
36486
ASH001965
0-160 PSI
36487
ASH001972
0-200 PSI
36488
ASH122905
0-300 PSI
36489
ASH102563
0-30 PSI
36490
ASH150397
0-600 PSI
36491
ASH142231
0-1000 PSI
36492
21/2” Dial, 1/4” Brass Lower Mount, ABS Case ASH001651 0-30 PSI 77875 ASH001668
0-60 PSI
77876
ASH001675
0-100 PSI
77877
ASH001682
0-160 PSI
77878
ASH001699
0-200 PSI
176518
4” Dial, 1/4” Brass Lower Mount, ABS Case ASH121946 0-15 PSI 36496
POL Valve Wrench Kit Handle
Wrench
POL Adapter
PART # VCT201 VCT202 VCT203
ASH001934
DESCRIPTION Polished pol Plugs Valve Wrench Handle 20-3
WEBB# 184417 184418 184419
The VICTOR Propane Equipment Catalog
ASH002603
0-30 PSI
36497
ASH002610
0-60 PSI
36498
ASH002627
0-100 PSI
36499
ASH002634
0-160 PSI
36500
ASH002641
0-200 PSI
36501
ASH141430
0-300 PSI
36502
21/2” Liquid Filled Dial, 1/4” Brass Lower Mount, ABS Case ASH005116 0-15 PSI 110914 ASH005123
0-30 PSI
110915
ASH005130
0-60 PSI
110916
ASH005093
0-100 PSI
110917
ASH005147
0-160 PSI
110918
ASH005154
0-200 PSI
110919
ASH005161
0-300 PSI
110920
ASH005178
0-400 PSI
110921
CYLINDER ACCESSORIES
OPD Cylinder Vise Wrench Kit
69
CYLINDER ACCESSORIES
70
CYLINDER ACCESSORIES
Cylinder Hand Trucks
PART # DESCRIPTION HPR70416 For LP Cylinders VCTNMP79004P For 420 lb. Cylinders
ASME Storage Containers Determining Propane Vaporization Capacity “Rule of Thumb” Guide for ASME LP-Gas Storage Containers
WEBB# 182214 190693
Cylinder Hand Truck
Where D = Outside diameter in inches L = Overall length in inches K = Constant for percent of volume of liquid in container L
Appliance Truck PART # HPREA6061
D
WEBB# 182215
Appliance Truck
Methanol Injector MFR # VCTTMI-1QL
DESCRIPTION Methanol Injector
WEBB# 215392
Hand Held Pump Style
Percentage of Container Filled
K Equals
* Propane Vaporization Capacity at 0 F (in BTU.hr.)
60
100
D x L x 100
50
90
D x L x 90
40
80
D x L x 80
30
70
D x L x 70
20
60
D x L x 60
10
45
D x L x 45
* These formulae allow for the temperature of the liquid to refrigerate to -20°F (below zero), producing a temperature differential of 20°F for the transfer of heat from the air to the container’s “wetted” surface and then into the liquid. The vapor space area of the vessel is not considered. Its effect is negligible.
MFR# DESCRIPTION WEBB# RIMABJ2 Methanol injector hand held pump style 186594
Vaporizing Capacities for Other Air Temperatures Multiply the results obtained with the above formulae by one of the following factors for the prevailing temperature. Prevailing Air Temperature (in Degrees F)
TMI-1QL Methanol Injector
Prevailing Air Temperature Multiplier (in Degrees F)
Multiplier
-15
0.25
+5
1.25
-10
0.50
+10
1.50
-5
0.75
+15
1.75
0
1.00
+20
2.00
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
TANKS
71 TANKS
Underground/Aboveground Tanks
Underground Tanks Part# G/T250UG G/T320UG G/T500UG G/T1000UG
Capacity in W.G. 250 320 500 1000
Outside Diameter (in) 30" OD 30" OD 37" OD 41" OD
Overall Length 7’ - 8" 9’ - 6" 10’ 0" 15’ - 10"
Overall Height w/26" Riser 38" 38" 65’ 69"
Weight 480 620 940 1800
Number Per Stack 5 5 5 5
Number Per Load 30 25 25 15
Webb# 185234 185238 185249 185225
Aboveground Tanks Part# G/T120AG G/T250AG G/T320AG G/T500AG G/T1000AG
Capacity in W.G. 120 250 320 500 1000
Overall Length 5’ - 7" 7’ - 8" 9’ - 6" 10’ - 0" 15’ - 10"
Outside Diameter (in) 24" OD 30" OD 30" OD 37" OD 41" OD
Leg Spacing 371/2" 60" 60" 60" 138"
Weight (lbs) 260 480 620 940 1800
Number Per Stack 14 9 9 6 5
Number Number Per Load 112 54 45 30 15
Webb# (White) 205731 185233 185237 185248 185224
Webb# (Gray) 198025 198024
AG/UG Tank Part# G/T120AG/UG G/T250AG/UG G/T320AG/UG G/T500AG/UG G/T1000AG/UG
Capacity in W.G. 120 250 320 500 1000
Overall Length 5’ - 8" 7’ - 9" 9’ - 11" 10’ - 0" 15’ - 10"
Outside Overall Diameter Height Leg (in) w/Riser & Leg Spacing 24" OD 36" 371/2" 30" OD 40" 60" 30" OD 40" 60" 37" OD 47" 60" 41" OD 51" 138"
Weight (lbs) 260 480 620 940 1800
# Per Stack 12 9 9 6 5
Number Per Load 96 54 45 30 15
Webb# 185228 202413 193388 194172 204553
500 Aboveground Tank with 11/4 Bottom Opening for Fill Stations Part# G/T500AG-B
Capacity in W.G. 500
Overall Length 10’ - 0"
Outside Diameter (in) 37" OD
Leg Spacing 60"
Weight (lbs) 950
Webb# 215818
All 1000 AG come standard with bottom 11/4 NPT opening.
How to Make Up a Mixed Truckload Model Diameter
120AG 24"
250AG 30"
320AG 30"
500AG 37"
1000AG 41"
1000AG 41"
Footprint
6’ 14-120
8’ 9-250 4-120 6-250 8-120 3-250 4-150 6-250 8-150 3-250
10’ 9-320 6-250 3-320 3-250 6-320
10’ 6-475
16’ 5-1000 3-1000 8-120 3-1000 6-250
20’ 1,525 3-1000 6-320 3-1000 4-500 3-1000 4-500
The VICTOR Propane Equipment Catalog
6-500 3-475 8-120 3-500 8-120 3-475 8-150 3-500 8-150 3-475 3-500
Notes • The chart for AG models is applicable to AG/UG and UG models with the following exceptions: 120 and 150 AG/UGs — stack drops from 14 to 12. 250 and 320 UGs — stack drops from 9 to 5 tanks. 475 and 500 UGs — stack drops from 6 to 5 tanks. • A maximum of 2 models of ASME tanks per stack. • A maximum of 1 mixed stack per load. Use longer length for calculating space required. • A full load must measure between 46’ and 50’. • We can ship 52’ (not allowed in some states) if the load meets additional criteria. (must be all AG tanks)
TANKS
72
TANKS Quality Steel Replacement Parts Q.S. PART# DESCRIPTION
PART#
Tank Size 120 01-001 Filler Valve 01-009-1 Float Gauge 01-021 Multi Valve, Tube length 6.7 01-007 Relief Valve 01-031 U/G Float Gauge
7579-T B8981-1186 or HA-130AQ 7556-RS 7583-GT JB-302
Tank Size 150 01-001 Filler Valve 01-009-1 Float Gauge 01-021 Multi Valve, Tube length 6.7 01-007 Relief Valve 01-008-1 Check Lok 01-031 U/G Float Gauge
7579-T B8981-1186 or HA-130AQ 7556-RS 7583-GT 7590-UT JB-302
Tank Size 250 01-001 Filler Valve 01-010-1 Float Gauge 01-023 Multi Valve, Tube length 8.5 01-007 Relief Valve 01-008-1 Check Lok 01-017 U/G Float Gauge, L.N.R. 01-045 U/G Float Gauge, S.N.R.
7579-T HA 156-AQ 7556-RS 7583-GT 7590-UT JB350B JB224B
Tank Size 320 01-001 Filler Valve 01-010-1 Float Gauge 01-023 Multi Valve, Tube length 8.5 01-007 Relief Valve 01-008-1 Check Lok 01-017 U/G Float Gauge, L.N.R. 01-045 U/G Float Gauge, S.N.R.
7579-T HA 156-AQ 7556-RS 7583-GT 7590-UT JB350B JB224B
Tank Size 475 01-001 Filler Valve 01-011-1 Float Gauge 01-002 Multi Valve, Tube length 10.5 01-012 Relief Valve 01-008-1 Check Lok 01-018 U/G Float Gauge, L.N.R. 01-046 U/G Float Gauge, S.N.R.
7579-T HA 194-AQ 7556-RS 8684-GT 7590-UT JB384B JB260C
Tank Size 500 01-001 Filler Valve 01-011-1 Float Gauge 01-002 Multi Valve, Tube length 10.5 01-012 Relief Valve 01-008-1 Check Lok 01-018 U/G Float Gauge, L.N.R. 01-046 U/G Float Gauge, S.N.R.
7579-T HA 194-AQ 7556-RS 8684-GT 7590-UT JB384B JB260C
Tank Size 1000 01-001 Filler Valve 01-016-1 Float Gauge 01-025 Multi Valve, Tube length 11.3 01-013 Relief Valve 01-008-1 Check Lok 01-019 U/G Float Gauge, L.N.R. 01-047 U/G Float Gauge, S.N.R.
7579-T HA 210-AQ 7556-RS 8685-GT 7590-UT JB404B JB280C
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
73
CATHODIC PROTECTION Cathodic protection for underground propane tanks
NFPA requires the use of good engineering practices to protect underground propane tanks from the action of soil electrolysis. Magnesium anodes attached to the tank lifting lug by use of the Cadweld System meets this requirement. PART NUMBER CPRCAHAA-1G
DESCRIPTION Vertical Cadwelder with Ignitor
WEBB# 183412
CPRCA-15
Weld Metal with Disk (box 20)
183410
CPRCAB133-1H
Sleeve (100 per pkg)
183411
CPRCAT-320
Replacement Flint Ignitor
183523
CPRB117A
Pkg. 20 Silver Discs Only
How the Cadweld Welder Works
Accessories CAHAA-16
CA-15
CAT-320 B117A
Magnesium Anodes
Pipe Wrap
Magnesium anodes have a 10’ length of #12 electric wire attached. PART NUMBER Anode 17
DESCRIPTION #17
WEBB# 183403
Anode 5
#5
215998
Typical Tank Anode Requirements TANK SIZE 500 Gals
17 LB ANODES REQUIRED 1
Iron Pipe Anode Requirements
WEBB# 243366
PAS9052
Black Pipe Wrap, 2” x 100’
81161
MISUD21
Underground Gas Detector Tape
183516
Typical small ASME container underground installation
PIPE PIPE SIZE LENGTH Install 0ne 5 lb. Anode 3/4” 500’
1000 Gals
2
11/4”
450’
3000 Gals
4
11/2”
425’
400 to 5000 Gals
6
2”
400’
10,000 Gals
8
15,000 Gals
10
Install 0ne 17 lb. Anode 3” 700’
20,000 Gals
12
14”
500’
25,000 to 30,000 Gals
14
6”
400’
8”
350’
The VICTOR Propane Equipment Catalog
PART NUMBER DESCRIPTION KMC4130 Yellow Pipe Wrap, 2” x 100’
CATHODIC PROTECTION
Cadweld System
PAINT & SUPPLIES
74
PAINT & SUPPLIES Premium Industrial Coatings Primers A single package epoxy primer of high quality that offers excellent corrosion resistance and fast re-coat time. This product is user friendly and offers great coverage.
Primers
PART NUMBER SUM855G1368
DESCRIPTION Gray-Green Primer
WEBB# 184237
SUM899W1370
Off White Primer
184238
Foot Ring Protector A protective coating that is modified with phenolic resins making this a great product for the bottoms of cylinders. When applied properly, this product aids in corrosion resistance. Can be mopped, brushed or sprayed. PART NUMBER SUM880N2209
DESCRIPTION Foot Ring Protector, Black
WEBB# 184248
White Paint Foot Ring Protector
White Paint
Blued White Tank enamel was formulated especially for Propane Tanks offering elasticity, excellent weathering, one coat coverage, and user friendly. Works great with rollers, brushing and also can be sprayed. Silicone Alkyd White is the premium of our Tank Enamels, modified with high percentage of silicone offering excellent gloss and color retention. This product is highly recommended for painting storage tanks when maximized coating life is a must. PART NUMBER SUM880W2203
DESCRIPTION WEBB# No. 5 Blued White Tank Enamel 184244
SUM880W2201
No. 7 Silicone Alkyd White
184249
Aluminum Paint Tank Coating is our most popular aluminum finish that has nearly 2 pounds of aluminum paste in every gallon. SC1000 was formulated using premium blend of oleoresinous varnishes. Strontium Chromate is the premium in our aluminum finishes, all the same great qualities of our SC1000 plus the addition of built in rust inhibitor.
Aluminum Paint
PART NUMBER SUM888S2205
DESCRIPTION SC1000 Tank Coating, Aluminum
WEBB# 184233
SUM888S2206
SC1110 Strontium Chromate, Aluminum
184234
SUM880S2207
Aluminum Enamel Paint
184235
Enviro-Tuff Industrial Enamels A high quality industrial enamel offered in an assortment of colors to personalize your tanks. This product is great for many other exterior uses.
Enviro-Tuff Industrial Enamels
PART NUMBER SUM880G0166
DESCRIPTION Green Enamel
WEBB# 184182
SUM880L0184
Tan Enamel
184239
SUM885N2100
Black Enamel
184240
SUM880D0130
Mist Gray
184236
SUM885R2108
Red
184241
SUM886Y8625
Industrial Yellow
184245
SUM886G8656
Safety Green
184246
DESCRIPTION XL Thinner
WEBB# 184251
Paint Thinner PART NUMBER SUM856X2210
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
75
PAINT & SUPPLIES Coverage Data: Enamels and Primers Tank Size (Gallons)
Approx Sq. Feet
No. 5 Blued White
No. 7 Silicone Alkyd White
100D8431 Hi Solids
Uni-Pox Primer 1370 Off White
30,000
1,950
7 Gallons
7 Gallons
7 Gallons
7 Gallons
7 Gallons
18,000
1,250
5 Gallons
5 Gallons
5 Gallons
5 Gallons
5 Gallons
12,000
1,150
4 Gallons
4 Gallons
4 Gallons
4 Gallons
4 Gallons
1,000
225
1 Gallon
1 Gallon
1 Gallon
1 Gallon
1 Gallon
500
115
2 Tanks Per Gallon
2 Tanks Per Gallon
2 Tanks Per Gallon
2 Tanks Per Gallon
2 Tanks Per Gallon
250
55
4 Tanks Per Gallon
4 Tanks Per Gallon
4 Tanks Per Gallon
4 Tanks Per Gallon
4 Tanks Per Gallon
Sq. Ft. Coverage per Gal. @ 1 dry mil
740
760
810
785
785
Recommended dft. per coat
1.5 - 2.5 mils 295 - 495 Sq. Ft.
1.5 - 2.5 mils 1.5 - 2.5 mils 1.5 - 2.5 mils 305 - 505 Sq. Ft. 325 - 540 Sq. Ft. 315 - 520 Sq. Ft.
Uni-Pox Primer 1368 Gray Green
1.5 - 2.5 mils 315 - 520 Sq. Ft.
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
Coverage Data: Aluminums and Primers SC 1000 Aluminum Tank Covering
SC 1110 Strontium Chromate
SC2000 Non-Glare Aluminum
High Solids Universal Primer
Epoxy Ester Primer 1370 Off White
7 Gallons
7 Gallons
8 Gallons
5 Gallons
5 Gallons
6 Gallons
4 Gallons
5 Gallons
Tank Size (Gallons)
Approx Sq. Feet
30,000
1,950
8 Gallons
8 Gallons
18,000
1,250
5 Gallons
5 Gallons
12,000
1,150
4 Gallons
4 Gallons
4 Gallons
1,000
225
1 Gallon
1 Gallon
1 Gallon
1 Gallon
1 Gallon
500
115
2 Tanks Per Gallon
2 Tanks Per Gallon
2 Tanks Per Gallon
2 Tanks Per Gallon
2 Tanks Per Gallon
250
55
4 Tanks Per Gallon
4 Tanks Per Gallon
4 Tanks Per Gallon
4 Tanks Per Gallon
4 Tanks Per Gallon
Sq. Ft. Coverage per Gal. @ 1 dry mil
635
665
740
810
615
Recommended dft. per coat
1.5 - 2.5 mils 255 - 425 Sq. Ft.
1.5 - 2.5 mils 1.5 - 2.5 mils 1.5 - 2.5 mils 265 - 445 Sq. Ft. 295 - 495 Sq. Ft. 325 - 540 Sq. Ft.
1.5 - 2.5 mils 250 - 415 Sq. Ft.
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
Paint Accessories PART NUMBER SUMSC-TTB002
DESCRIPTION 12” Trim Brush
WEBB# 184250
SUMKM-1009
5 Gal Bucket
192127
SUMSC-BC003
Bucket Cover (3 per pkg)
192913
SUMSC-BG-001
Bucket Grid
242094
SUMSCLV16
9” Lambswool Roller Cover
184195
SUMSC-CR006
Contour Roller Cover
184192
SUMSC-TR09K
9” Roller Handle
184247
SUMSC-EP03P
42” Extension – 3 pc.
242095
SUMSC-WB042
Pole Wire brush
SUMSC-CR063
Contour Roller Complete
Contour Roller Complete Bucket Grid
42” Extension
5 Gallon Bucket
12” Trim brush
The VICTOR Propane Equipment Catalog
Wire Brush
Roller Handle
Bucket Cover
Lambswool Roller Cover
PAINT & SUPPLIES
Premium Industrial Coatings (cont.)
SIGNS/DECALS
76
SIGNS/DECALS
Signs & Decals Reflective Warning Scotchlite Decals PART # S22-A S22-B S22-C
DESCRIPTION Railroad Crossing Railroad Crossing Railroad Crossing
SIZE 8” x 36” 4” x 36” 8” x 12”
S29
Railroad Crossing
4” x 36”
Updated Test & Retest Kits WEBB# 181431
PART # V31 V32
DESCRIPTION Periodic Inspection Chart 5 Year Inspection Kit
SIZE 6” x 18” 6” x 18”
WEBB#
S22-A S22-B
V31
S22-C
S29
Fuel Signs Unless otherwise indicated, the items following are red letters on white background. A = 6” letters M = Metal (Aluminum B = 4” letters S = Scotchlite® Brand Reflective BB = 3” letters V = Vinyl C = 2” letters P = Polyethylene (plastic) D = 1” letters PART # V72 V288-BB V58 P101 V62 V47
DESCRIPTION Safety First (Blue Only) Propane Gas LPG (Black on Orange) Capacity Chart (Red/Blue on Poly) Sheet of 10 Labels (Black on Yellow) Propane
SIZE
WEBB#
V32
No Smoking Sign PART # V49
DESCRIPTION SIZE No Smoking Vinyl (stick-on Decal) 10” x 42”
WEBB# 188815
192754 21/2” x 3”
V49
4” x 51/2” 9” x 38”
Placard Holder PART # MPH69
DESCRIPTION .050 Aluminum w/Baked Enamel Finish & Stainless Steel Clip
WEBB# 181423
V288-BB
MPH69
V58 V72
D.O.T. Placarding for Bulk Transporters PART # V1075 P1075 G1075
DESCRIPTION Vinyl Polyethylene Magnetic Blanket
WEBB# 181435 181426 181418
P101
V47
V62
V1075 P1075 G1075
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
77
SIGNS/DECALS OPD Signs
Storage Tank Diamond for Propane Red, Yellow, Blue & Black on White Vinyl PART # V704-3 V704-1
DESCRIPTION 300’ legibility 100’ legibility
SIZE 15” x 15” 7.5” x 7.5”
WEBB#
PART # P114 P111
DESCRIPTION SIZE Retrofit Chart (Blue on White Poly) 18” x 24” Alert Sign (4 Holes & 2 Colors) 16” x 20”
WEBB#
V704-3 V704-1
Danger Sign PART # SP53-R
DESCRIPTION Black on Yellow Vinyl
SIZE 4” x 9”
P111
WEBB# 181434
P114
Liquid/Vapor Signs PART # V90 V90-5 V91-5
DESCRIPTION Vinyl Polyethylene Vinyl Polyethylene Black on Yellow Vinyl
V121/P121
SIZE 1” x 4” 1” x 4” 1” x 4”
WEBB#
V90
Filling Procedure Decals PART # V121 P121 V122 P122 V79
DESCRIPTION Red on White Vinyl Red on White Vinyl (5 per Sheet) Red on White Vinyl (5 per Sheet)
SIZE 11” x 12” 11” x 12” 11” x 12” 11” x 12” 2” x 31/2”
WEBB# 192753
V90-5
V91-5
Emergency Signs PART # V81 P81 V82 P82 11-V-127 11-P-127
DESCRIPTION Pull – Red on White Vinyl Pull – Red on White Polyethylene Push – Red on White Vinyl Push – Red on White Polyethylene Red on White Vinyl Red on White Polyethylene
SIZE 10” x 12” 10” x 12” 10” x 12” 10” x 12” 12” x 30” 12” x 30”
WEBB#
192752
V122/P122 V81/ P81
V82/ P82 11-V-127 11-P-127
V79
The VICTOR Propane Equipment Catalog
SIGNS/DECALS
Signs and Decals (cont)
SIGNS/DECALS
78
SIGNS/DECALS
Signs and Decals (cont) Propane Filling Station Signs
Portable Cylinder Labels PART # A16 A16-STR AA16 A53
DESCRIPTION Curved, Black Imprint Straight, Black Imprint Not Curved Black on White Vinyl
SIZE
1.5” x 5”
WEBB# 181416 181451 181417 223683
PART # M97A M97-AX M97-AD M97-AXD V14 C37 M97-FR
DESCRIPTION Single Faced (Blue on White Aluminum) Exchange (Blue on White Aluminum) Double Faced (Blue on White Aluminum) Exchange (Blue on White Aluminum) Red & Black on White Vinyl Red & Black on Coroplast Frame for 2’ x 4’ Signs w/hardware
SIZE WEBB# 2’ x 4’ 181421 2’ x 4’ 181422 2’ x 4’ 181413 2’ x 4’ 12” x 16” 12” x 24” 181444
A16 (Curved)
A16 (Straight) AA16
A53
Hazard Sign PART # HZ116
DESCRIPTION Blue, Yelloe, Red & Black
SIZE 21/2” x 5”
WEBB# 181419
M97A, M97AD
WEBB#
V14
M97AX, M97AXD
No Smoking While Refueling Decals PART # V266
DESCRIPTION Red on White Vinyl
SIZE 24” x 36”
V26-A
Red on White Vinyl
12” x 18”
V26-B
Red on White Vinyl
12” x 18”
M26-C
Baked Enamel on Aluminum
24” x 36”
C37
Brady Label Maker VersaPrinter™ 181441
Quickly create any type of label or sign and print as many as you need in a matter of minutes. . . right from your own computer!
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMP STATION KITS
The VICTOR Propane Equipment Catalog
PUMP STA TION KITS
Pump Station Without Meter
79
PUMP STATION KITS
80
PUMP STATION KITS Pump Station Without Meter (cont.)
Pump Station Schematic Drawing Key No Meter 1
QTY ALPHA CODE 1 G/T1000AG
DESCRIPTION 1000 gal Above ground LP Tank
WEBB# 185224
1
1
G/T500AG-B
500 gal Above ground LP Tank
215818
2 (A,B,C)1
VCTTANKST
Victor Tank Stands, Pump Mount, and Meter Mount
184438
11/4” x 21’ sch40 black pipe price per foot. Use 2 full lengths each leg for 1000 gal, cut 2 to 16' for 500 gal
45533
DRAWING
3
42’ D/P114BPE
4
Checklok Emergency Liquid Evacuation Valve (possible Rego 7590U)
5
Pol Service/Vapor Evacuation Valve (possible Rego 7556R12.0)
6
Double Check Filler Valve (possible Rego 7579)
7
1
RGOA8017DP
Bottom Tank Valve Liquid Service 11/4” x 1”
8,9
1
CRKC12SMB
Corken pump C12SMB 11/2" inlet 1" outlet 1 hp motor with switch mounted on motor and B166 bypass 181039
10
1
NIPCS114X1XH 11/4” x 1” Concentric Swedge Nipple XH
11
2
F/S114903SE
12
1
NIP114X10XH 11/4” x 10” XH black nipple
11/4” 90 Elbow 3000# Forged Steel Threaded
162493 187220 8693 187212
13
1
SCSB112AD-114 11/4” Ductile Iron Strainer Threaded
184114
14
1
F/S34PL
3/4” Plug 3000# Forged Steel square head threaded
8831
15
1
NIP114X8XH
11/4” x 8” XH black nipple
14636
16
1
FLES125-12
11/4” x 12” Stainless Steel double braided flex connector with sch80 threaded ends
187501
17
1
F/S114UN3SE
11/4” Union 3000# Forged Steel Threaded
9101
18
1
F/S112X114BU 11/2” x 11/4” Bushing Forged Steel
19
1
NIPCS1X34XH 1” x 3/4” Concentric Swedge Nipple XH
187219
20
1
F/S34T3SE
3/4” Tee 3000# Forged Steel Threaded
8715
21
4
NIP34X6XH
3/4” x 6” XH black nipple
14602
22
1
RGO3127U
Rego 1/4” Hydrostatic relief valve 450#
162428
25
1
F/S14S903SE
1/4” Street 90 Elbow 3000# Forged Steel Threaded
8723
26
1
CRK1449
Corken gauge adapter / pressure snubber 1/4” M/F
181098
8872
27
1
RGO1224WA
Rego 1/4” needle valve
186802
28
1
F/S14CO3SE
1/4” Coupling 3000# Forged Steel Threaded
8732
29
1
ASH122905
Ashcroft 21/2” dial 1/4” bottom connection 0-300 psi
36489
31
21 D/P34XHBPE
3/4” x 21’ sch 80 black pipe price per foot
45478
30
6
F/S34903SE
3/4” 90 Elbow 3000# Forged Steel Threaded
8691
32
1
RGO7550P
Rego 3/4” Angle valve M/F
162760
33
1
RGO7590U-10 Rego Check-lok Adapter, possible alternate RGO7572-14C for older style check-lok
162762
34
1
F/S34CO3SE
8735
35
2
HGR1GUBOLT 1” Galvanized U-bolt with nuts
69033
36A
3
HOS3/4
185604
36B
2
HOSHY12-12MP3/4" Hydraulic hose ends for Dayco hose
185576
37
1
RGOA2141A6
162683
38
1
F/S34X12BU
39A
18 HOS1/2
3/4” Coupling 3000# Forged Steel Threaded
3’ - 3/4” LP Dayco Hose Rego 3/4” breakaway/pullaway coupling 3/4” x 1/2” Bushing 3000# Forged Steel
8857
18’ - 1/2” LP Dayco Hose
185581
39B
2
HOS7661-08MP08TY1/2" Hydraulic hose ends for Dayco hose
193208
40
1
RGO7901TB
162488
Rego 1/2” x 1/4” Snap acting Hose Valve
41
1
RGO7193D-10 1/4” x Mpol Rego hose adapter
186884
not shown
1
RGO7193T-10
Fpol x 15/16 F Acme adapter Rego F Pol-QCC1 adapter
162472
not shown
1
FBS1124
Fairbanks 1124 1000# scale
181957
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMP STATION KITS
The VICTOR Propane Equipment Catalog
PUMP STA TION KITS
Pump Station With Meter
81
PUMP STATION KITS
82
PUMP STATION KITS Pump Station With Meter (cont.)
Pump Station Schematic Drawing Key With Meter 1
QTY ALPHA CODE 1 G/T1000AG
1
1
2 (A,B,C)1
DRAWING
3
DESCRIPTION 1000 gal Above ground LP Tank
WEBB# 185224
G/T500AG-B
500 gal Above ground LP Tank
215818
VCTTANKST
Victor Tank Stands, Pump Mount, and Meter Mount
184438
11/4” x 21’ sch40 black pipe price per foot. Use 2 full lengths each leg for 1000 gal, cut 2 to 16’ for 500 gal
45533
42’ D/P114BPE
4
Checklok Emergency Liquid Evacuation Valve (possible Rego 7590U) Supplied by tank manufacturer
5
Pol Service/Vapor Evacuation Valve (possible Rego 7556R12.0) Supplied by tank manufacturer
6
Double Check Filler Valve (possible Rego 7579) TO BE REPLACED Supplied by tank manufacturer
7
1
RGOA8017DP
Bottom Tank Valve Liquid Service 11/4” x 1”
8,9
1
CRKC12SMB
Corken pump C12SMB 11/2”inlet 1” outlet 1 hp motor with switch mounted on motor and B166 bypass 181039
10
1
NIPCS114X1XH 1/4” x 1” Concentric Swedge Nipple XH
187220
11
2
F/S114903SE
8693
11/4” 90 Elbow 3000# Forged Steel Threaded
162493
12
1
NIP114X10XH 11/4” x 10" XH black nipple
187212
13
1
SCSB112AD-114 11/4” Ductile Iron Strainer Threaded
184114
14
1
F/S34PL
3/4” Plug 3000# Forged Steel square head threaded
8831
15
1
NIP114X8XH
11/4” x 8” XH black nipple
14636
16
1
FLES125-12
11/4” x 12” Stainless Steel double braided flex connector with sch80 threaded ends
187501
17
1
F/S114UN3SE
11/4” Union 3000# Forged Steel Threaded
9101
18
1
F/S112X114BU 11/2" x 11/4” Bushing Forged Steel
8872
19
1
NIPCS1X34XH 1” x 3/4” Concentric Swedge Nipple XH
187219
20
1
F/S34T3SE
3/4” Tee 3000# Forged Steel Threaded
8715
21
4
NIP34X6XH
3/4” x 6” XH black nipple
14602
22
1
RGO3127U
Rego 1/4” Hydrostatic relief valve 450#
162428
25
1
F/S14S903SE
1/4” Street 90 Elbow 3000# Forged Steel Threaded
8723
26
1
CRK1449
Corken gauge adapter / pressure snubber 1/4” M/F
181098
27
1
RGO1224WA
Rego 1/4” needle valve
186802
28
1
F/S14CO3SE
1/4” Coupling 3000# Forged Steel Threaded
8732
29
1
ASH122905
Ashcroft 21/2” dial 1/4” bottom connection 0-300 psi
36489
31
21 D/P34XHBPE
3/4” x 21’ sch 80 black pipe price per foot
45478
30
6
F/S34903SE
3/4” 90 Elbow 3000# Forged Steel Threaded
8691
36A
3
HOS3/4
3’ - 3/4” LP Dayco Hose
185604
36B
2
HOSHY12-12MP 3/4” Hydraulic hose ends for Dayco hose
185576
37
1
RGOA2141A6
Rego 3/4” breakaway/pullaway coupling
162683
38
1
F/S34X12BU
3/4” x 1/2” Bushing 3000# Forged Steel
8857
39A
18 HOS1/2
18” - 1/2” LP Dayco Hose
185581
39B
2
HOS7661-08MP08TY 1/2” Hydraulic hose ends for Dayco hose
40
1
RGO7901TB
41
1
RGO7193D-10 1/4” x Mpol Rego hose adapter
186884
42
1
RGO3272G
Rego 3/4” Excess Flow Valve 20gpm
162584
43
1
LIQLPM102
Liquatech 3/4” meter 20gpm no printer
182604
44
1
RGOA8018DP
Rego Multi Valve with filler (replaces 7579 filler valve)
45
1
SAE38X14MUN 3/8” M Flare x 1/4” Mnpt adapter
19780
Rego 1/2” x 1/4” Snap acting Hose Valve
193208 162488
187076
46
2
SAE38RNUT
3/8” Heavy Forged Short Flare Nut
34571
47
1
SAE2005
M Pol x 3/8” M Flare adapter
73293
not shown
1
RGO7193T-10
Fpol x 15/16 F Acme adapter Rego F Pol-QCC1 adapter
162472
not shown
1
FBS1124
Fairbanks 1124 1000# scale
181957
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
GAUGES
83
49S Application The “One” Gauge™ is a magnetically-coupled liquid-level gauge that adjusts in length and accepts a variety of float stem lengths. This feature makes it easy to quickly and economically replace non-functional gauges in the field for a large variety of tank sizes. They are UL listed. General Information & Features This gauge features a range of adjustable stems which, when mated with an appropriate-length float assembly, enables LP Gas dealers to easily replace the liquid-level gauge in virtually all LP Gas tanks used for domestic storage or mobile applications. Models are available with Junior™ bolted heads in aluminum or brass, Senior™ bolted heads in aluminum, and a version with a Junior™ 11/4” or 1” male NPTF brass head. The design utilizes a square-brass centershaft telescoping inside a square-aluminum pinionshaft, both of which are housed in telescoping aluminum support tubes. An aluminum locknut compresses an aluminum locking sleeve to secure the tubes at the required stem length. All other components are of the same materials as standard Rochester LP Gas gauges. The proper float assembly is attached to the gear housing on the adjustable stem per instructions shown below. Instructions For Assembling 1. After adjusting gauge stem to required length, and before tightening locknut, check for centershaft play at pinion gear. If pinion does not turn freely, insert a screwdriver between the end of the centershaft and gear housing. Pinion should turn freely but without excessive play. Then tighten locknut.
2. Hold pinion with stake mark up, as shown, and insert the cross stud on the appropriate float assembly into the pivot point bearing allowing tooth “A” to mesh with pinion.
3. Turn gauge assembly over, making sure gears remain meshed. Check to see that pointer on dial is at 50%. Place the Truarc ring into the assembly tool, then push ring into the groove on the projecting cross stud. Check to ensure the float falls under its own weight, and that the dial pointer travels from empty to full when the float is moved through its full arc.
The VICTOR Propane Equipment Catalog
Materials of Construction Head Aluminum or brass Drive Magnet Alnico Centershaft Brass Pinionshaft & Support Tubes Aluminum
Gears, Cross Stud, & Bearings Stainless steel Gear Housing Zinc Approvals Gauges are UL listed for LP Gas service applications
When ordering, specify: 1. Gauge head size (Jr., Sr., 11/4” NPTF, or 1” NPTF). 2. Aluminum or brass. 3. Tank diameter, shown on nameplate. 4. Mounting location (top, side, end, or angle). 5. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline, or the distance in inches above or below the horizontal centerline to the center of the gauge opening. 6. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellisoidal). 7. Specify the “H” dimension. This is the distance in inches from the surface of the tank to the top of the mounting surface.
GAUGE S
The “One” Gauge™ Adjustable Liquid-Level Gauge
84 GAUGES GAUGES
Magnetic Liquid-Level Gauges For LP Gas Service 6200 Application Junior gauges are supplied standard with 0015-00007 Buna-N gasket and four 004000414 zinc-plated steel mounting screws (1/4” — 28 x 7/8”) for attachment to a gauge adapter with 2.03” [51,5] diameter bolt circle (see Rochester Machining Standard MS-501). Models 6281 and 6284 Junior gauges used on above ground ASME storage tanks are equipped with direct reading 5323S01749 percentage dials. Model 6281 Junior gauges used on below ground ASME storage tanks are equipped with direct-reading 5323S01813 percentage dials. Models 6241 and 6244 Junior gauges used on ASME motor fuel tanks are equipped with direct-reading 5323S01789 fractional dials. General Specifications Temperature Range Standard range is -40°F to 158°F, -40C to 70C. Accuracy Dependent on proper sizing of gauge and tank configuration. When equipped with Jr.™ dial, overall accuracy is ±5%, Sr.™ dial is ±3%, TwinSite™ sender is ±5%, 4” dial is ±3%. Humidity For high humidity below ground or under chassis applications, brass, stainless steel, or painted aluminum heads are recommended. Shock & Vibration Suitable for mobile service applications. Current 200 mA maximum on TwinSite™ versions. System Voltage 12 to 24 volts on TwinSite™ versions. Working Pressure 375 psi. [25,8 Bar] Approvals Gauges are UL listed for LP Gas service applications.
6244 - 71/2”- 14 B75
Model number = 6244 Support length = 71/2” Tank Diameter = 14” Mfg date = B75 NOTE: Gauge head may also be stamped with model & unique suffix #.
When ordering, specify: 1. Gauge head size, Junior or Senior, or model #. 2. Tank diameter as shown on nameplate. 3. Mounting location (top, side, end or angle). 4. If gauge is angle mounted, state angle. 5. If gauge is end mounted, state the shape of the tank head, hemispherical or semi-ellipsoidal. 6. The “H” dimension, the distance in inches from the surface of the tank to the top of the gauge opening. To order replacement gauge, simply furnish the information stamped on one of the flat sections on the side of the gauge head as shown in the example.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
GAUGES
85
6300 Series Application The 6300 Series Magnetel™ liquid-level gauges are designed to accurately determine the percentage of total tank volume for most liquids in stationary-storage applications. UL listed for LP Gas and NH3 service. General Information & Features These Magnetel™ Gauges are available in four basic models: Model 6336 —Incorporates 4” [100 mm] dial and is designed for top mounting. Model 6360 —Incorporates 8” [200 mm] dial and is designed for top mounting. Model 6339 —Incorporates 4” [100 mm] dial and is designed for side, end or angle mounting. Model 6342 —Incorporates an 8” [200 mm] dial and is designed for side, end or angle mounting. The large, easy-to-read dials are also easy to remove and replace. Materials of construction vary depending on the types of liquids to be gauged. Many different optional fea- tures are available to meet your specific needs. These materials and options, along with their pricing impact, are summarized for each model in price list 6300. Magnetel™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.
Drawing A Part Number 0022-00029 0022-00525
Drawing B
Mates With Type Material Threads Dimensions 6300 Series 21/2" NPT Reference dwg A Y6300 Series 2" NPT Forged Steel 1/2" - 13UNC-2B Reference dwg B Only sch. 80
Webb#
When Ordering, Specify: 1. Liquid to be gauged and specific gravity. 2. Inside diameter of tank, head style: ellipsoidal, semi-ellipsoidal or hemispherical. 3. Complete model number desired from price list 6300, (example M6342-11). 4. Prefix letters for available options from price list 6300. 5. If a dial other than standard is required, furnish drawing and/or details. 6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installation in vertical tanks. 7. Tank mounting flange, if required (see chart). NOTE: The dimensions of the threaded neck on this adapter are equivalent to Schedule 80 pipe. CAUTION: For LP Gas or NH3 applications requiring 2” NPT connection, specify Y6300 Series Magnetel™ gauges which includes 0022-00525 schedule 80 adapter assembled to gauge.
The VICTOR Propane Equipment Catalog
GAUGE S
Magnetel™ Liquid-Level Gauges
86 GAUGES GAUGES
Magnetel™ Rough Rider™ Liquid-Level Gauges M6300 Application The M6300 series Magnetel™ Rough Rider™ gauges were designed to withstand the vibration and shock inherent in mobile service. Their service life in over-the-road and off-road transports, carrying liquids ranging from LP-gas to crude oil, is unsurpassed. These gauges allow a continuous reading between 5% and 95% of tank contents. General Information & Features The Magnetel™ Rough Rider™ gauges are to be installed in the side or end of mobile tanks at the centerline. They are equipped with an exclusive spring controlled shock absorber on the float arm which substantially reduces the stress that quickly destroys conventional gauges. Angle mounting gauges are also available. The M6339 incorporates a 4” [100 mm] dial and the 6342 incorporates an 8” [200 mm] dial. When necessary, the dials are easily replaceable. Refer to price list P6300 for available types, part numbers, etc., as well as other replacement parts and accessories. Price list M6300 includes information on materials of construction, available options, and sales and pricing policy. The Magnetel™ Rough Rider™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.
Drawing A Part Number 0022-00029
Mates With 6300 Series
Type Material Threads Dimensions 21/2" NPT Forged Steel 1/2" - 13UNC-2B Reference dwg A
Webb#
When Ordering, Specify: 1. Liquid to be gauged and specific gravity. 2. Inside diameter of tank heads, ellipsoidal, semi-ellipsoidal or hemispherical. 3. Complete model number desired from price list 6300, (example M6342-11). 4. Prefix letters for available options from price list 6300. 5. If a dial other than standard is required, furnish drawing and/or details. 6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installation in vertical tanks. 7. If tank mounting flange is required, order separately from chart above.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
GAUGES
87
R6315 Application This transmitter is designed to fit Rochester model 6342 and 6360 Magnetel™ Float gauges with 8” dials. General Information & Features The model R6315-12 transmitter utilizes a 5kW proportional output conductive plastic potentiometer and electronic circuitry to provide a current output of 4-20 mA, which is proportional to the liquid volume in a horizontal cylindrical storage tank. It should be used with intrinsically safe voltage input from a loop-power supply and safety barrier. Rear, side and front views
Wiring Diagram of Typical Installation
General Specifications 4-20 mA output 12-24 VDC input Conformity ± 1.5% Load 495 ohms or less Note: 1. If using loop-powered indicator, specify 0083S00001,24 VDC power supply. 2. Transmitter will operate at between 12 and 40 volts. The barrier will drop 3.6 volts at 20 mA. Total resistance added to the line for voltage generation and readouts should be less than 495 ohms for proper operation with 25.5 volts, intrinsic safe limit for most barriers. 3. Digital liquid-level indicator cannot use or generate more than 250 VAC.
The VICTOR Propane Equipment Catalog
GAUGE S
Magnetel™ Liquid-Level Transmitter
GAUGES
88 GAUGES The Eliminator™ Rotogauge Replacement For LP Gas & NH3 Service
P6293 Series Application The Eliminator™ direct-reading float gauge is a direct replacement for 1” NPT rotarytype dip-tube gauges in LP and NH3 storage tanks. These gauges are designed for larger tanks up to 84” [2134mm] in diameter. The Eliminator™ is not intended for use in filling tanks - its use is restricted to tanks with fixed liquid level gauges, used to determine when the maximum fill level has been reached. The eliminator can be used in mobile applications up to 60” [1524mm] in diameter. How To Do The Conversion 1. After the storage tank has been evacuated, remove the rotary gauge from the 1” NPT opening at the centerline of the head. Clean and re-tap the female threads. 2. Remove the 2 screws from the bezel. Put the bezel, screws and dial chamber aside for the moment. Remove the 4 mounting screws holding the gauge head to the adapter. 3. Insert the lower portion of the replacement gauge, including the float bulb, float arm, gear housing and counterbalance, into the tank opening. 4. Apply three wraps of 1/2” [12mm] wide Teflon tape, or other suitable thread sealant, to the 1” NPT threads on the steel adapter through which the gauge support passes. 5. Screw the adapter into the tank opening to achieve a leak-tight joint, and align the gauge mounting holes in the horizontal plane. 6. Using the gasket and four mounting screws supplied, attach the gauge to the adapter fingertight. Be sure the gauge is right side up, the bracket tab for locating dial chamber should be on the right. Torque the mounting screws evenly to 140/150 lb.in., [16,4Nm] using a cross pattern. 7. Reattach the 4” dial chamber and bezel to the Senior™ gauge head brackets using the two screws supplied. 8. If you end up with the dial chamber upside down, you cannot solve the problem by rotating the bracket. You must rotate the entire gauge 180°. Part Number P6293-R4400 P6293-R6000 P6293-R7200 P6293-R8400
Fits Tank Size O.D. Up to 44" 44" - 60" 61" - 72" 73" - 84"
When ordering, specify: 1. Model number. 2. Tank I.D. 3. Shape of the head.
Webb#
Warning: Carefully ensure that gauge and adapter are adequately protected from damage that might cause leakage of tank contents.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
GAUGES
89
7200/B7200 Application The 7200 and B7200 Series Junior™ gauges are identical except the former has a zinc die-cast head and the latter has a forged-brass head. Both types have 11/4” Male NPTF threads and 2” [51] hex- wrenching sections and are equipped with direct-reading dials appropriate for the tanks in which they are installed. General Information & Features Model 7281 and B7281 direct-indicating gauges are for top mounting. When used on above-ground ASME, horizontal, domestic storage tanks, they are equipped with 5323S01749 percentage or 5323S01789 fractional dials. When used on tanks buried underground, they are equipped 5323S01813 percentage dials. Most 420# [190 kg] vertical cylinders utilize the 5323S01835 dial. For dials used on other vertical cylinders, contact Rochester. Model 7284 and B7284 gauges are for side, end or angle mounting. When used on ASME motor-fuel tanks they are equipped with 5323S01789 fractional dial. Please contact Rochester for the part numbers of the various dials used on gauges mounted in lift-truck cylinders. General Specifications Temperature Range Standard range is -40°F to 158°F, -40C to 70C. Accuracy Dependent on proper sizing of gauge and tank configuration. With direct reading dials, overall accuracy is ±5%; with TwinSite™ Sender, overall accuracy is ±5%. Current TwinSite™ versions, 200 mA. maximum Voltage TwinSite™ versions, 12 and 24 volts. Working Pressure 375 psig [25, 8 Bar]. Approvals Gauges are appropriately UL listed for LP Gas liquid-level service and/or LP Gas automotive accessories.
Typical Gauge
When ordering, specify: 1. The tank inside diameter (shown on tank nameplate). 2. The mounting location (top, side, end or angle). 3. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline. 4. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellipsoidal). 5. The “H” dimension. This is the distance in inches from the surface of the tank to the top of the threaded opening.
The VICTOR Propane Equipment Catalog
GAUGE S
Magnetic Liquid-Level Gauges For LP Gas Service
90 GAUGES GAUGES
Advanced Matrix Film TwinSite™ For LP Gas Service TS011 Application The TwinSite™ is a magnetically-driven, variable-resistance sender with potted lead wires. Senders are utilized on mobile applications where direct reading plus an electrical signal to a remote receiver are required. Models are available to fit all Rochester Junior™, liquid-level gauges equipped with our large Alnico drive magnet. General Information & Features This 2-wire TwinSite™ sender employs a laser trimmed, advanced matrix resistance element. The TwinSite™ is capable of generating accurate and reliable signals to remote receivers in most common resistance ranges with infinite resolution (see the back side for the technical specifications). The standard model of this TwinSite™ comes with the premium harsh environment construction at the price of the previous standard unit. The dedicated ground path terminal wire eliminates the major reliability fault found in most variable resistance sender designs. Redundant wiper and collector contacts are used to improve reliability and reduce contact noise. In testing, this unit has greatly surpassed the competitive units in reliability and durability. The case is hermetically sealed by ultrasonic heating to melt and fuse the case into one solid piece. This keeps weather out, ensuring “no-fog” readability while greatly extending mechanical life. The seal is a high reliability, no-gasket design. The plastic case is capable of withstanding vibration and shock that would render comparable metal designs useless. The plastic lens (and the rest of the case) is a special, UV stabilized material.
Standard screw-on mount
Standard snap-on mount
The sender is mounted onto the Rochester Junior™ gauge with #0040-00416 stainless steel dial screws (6 — 32 x 5/16”). An additional item available to ensure weatherproof connections from the TwinSite™ to the receiver is heat shrink solder sleeves part number 0025-00495. When ordering, specify: General Specifications 1. Gauge model number. Operating Temperature 2. Tank diameter and riser height. - 40°F to 158°F, -40C to 70C 3. Mounting location. Power Rating 4. Any listed options. 0.5 Watt or peak current of 200mA over a temperature range of -40C to 70C How to Order Accuracy RANGE SENDER NOTES ±5% for all types 0-30Ω IP5644S02545 — Hysteresis 0-90Ω IP5628S02537 — Less than 5% typical, not vibrated 70-10Ω IP5630S02538 — Repeatability 105-10Ω IP5638S02542 — ±2% 20-150Ω IP5663S02527 — Voltage Range System voltages of 12 & 24 VDC 20-150Ω IP5619S02527 With Packed Connector Resolution 0.10Ω IP5731S02597 3-Wire With Packed Infinite Connector Resistance Change With Temperature 40-250Ω IP5752S02599 — 0° to ±100° PPM/C 112-6Ω IP5679S02560 — Vibration Tested for mobile applications
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
GAUGES
91
MS-501/502 Figure A
Figure B
Is the gauge right for your application? Gauges should only be installed in applications recommended by the manufacturer. Verify that the gauge is the proper gauge for your application prior to attempting installation. The float may or may not have a counterbalance depending on the intended application. Applications for light specific gravity liquids or large tanks normally require counterbalancing of the float. The gauge, mounting gasket and mounting adapter (if applicable) must be constructed of materials compatible with the liquid to be measured and the service environ ment. The float, mounting screws and head must be adequately rated for your specific pressure and temperature service. Is the gauge the proper size? As a general rule, the float pivot point should be on the horizontal centerline of the tank when installed. The float length dimension (measured from the float pivot point to the end of the float) should be proportional to the inside tank height and is usually slightly less than 1/2 of the vertical inside height of the tank. Gauges can be constructed for side, top or angle mounting but must be installed in the position for which they are constructed. Hold the gauge by the support (see Figure A) in the intended mounting attitude and operate the float to see if it is correct for your application (see Figure B). CAUTION: Improper gauge or dial selection or application may result in inaccurate readings. Release of tank contents as well as damage to equipment and safety hazard may result if tank is overfilled. Fuel exhaustion may occur if tank contents are less than indicated. LP Gas & NH3 gauge dials require an appropriate temperature chart. WARNING: This gauge is not a substitute for a fixed liquid level gauge or weight measurement device, which may be required for filling. GAUGE REMOVAL WARNING: Should it appear necessary to remove the gauge from the tank, do not attempt removal unless under competent supervision with all due precautions taken against the hazards of released liquid or high pressure and/or flammable gas.
MS – 502 Sr. Gauges
HAZARDS: A hazard of fire or explosion may exist if proper methods are not used when removing or installing the gasket. Replace gasket if gauge head is removed. Do not reuse gasket. When reinstalling gauge align head for proper orientation of the float inside tank.
Installation Check color stripe on O.D. of gasket for material.
CAUTION: Use spiral wound gasket only with stainless steel gauge head and allen head cap screws. A. Fit gasket onto gauge boss. B. Carefully insert float into adapter or coupling and work gauge’s gear housing and support through adapter being careful not to bend or damage them. C. Check to see that gasket is properly sealed in adapter gasket recess. D. Align head for proper orientation of float inside of tank. Torque screws evenly in several steps to the desired torque value. When torquing use a crossing torque pattern.
BLUE STRIPE= NEOPRENE. Order Senior™ part # 0015-00836 or Junior™ part # 0015-00855 recommended for anhydrous ammonia and specific refrigerant applications. RED STRIPE= BUNA-N. Order Senior™ part # 0015-00004 or Junior™ part # 0015-00007, recommended for specific LP Gas & petroleum applications. BROWN STRIPE = VITON. Order Senior™ part # 0015-00415 or Junior™ part # 0015-00039. WHITE GASKET = TEFLON. Order Senior™ part # 0015-00401 or Junior™ part # 0015-00405. SPIRAL WOUND TEFLON AND STAINLESS STEEL. Order Senior™ part # 0015-00462. CAUTION: Do not over torque. Do not re-torque later unless leaking. Over tightening may cause damage to head and gasket. SCREW SIZE 1/4 – 28 5/16 – 24 5/16 – 24
The VICTOR Propane Equipment Catalog
DRY TORQUE 20 TO 50 IN.LB [2,3 to 5,6 Nm] 30 TO 60 IN.LB [3,4 to 6,8 Nm] 140 TO 150 IN.LB [15,8 to 16,9 Nm]
GASKET TYPE BUNA, NEOPRENE, VITON, TEFLON BUNA, NEOPRENE, VITON, TEFLON SPIRAL WOUND GASKET
GAUGE S
Jr. & Sr. Gauge Installation
92 GAUGES GAUGES
Threaded Gauge Installation MS-516
Figure A
These instructions are prepared to assist tradesmen and others generally familiar with liquid storage tank equipment. Consumers are not qualified to perform the installation described below. If you have any questions concerning installation or operation of the gauge, contact Rochester Gauges or one of our authorized distributors for assistance. This document is not instructions for tank filling. Figure B
An American National Standard Pipe Threads, General Purpose (INCH) ANSI/ASME B1.20.1-1983 (Varnish threads due to chamfer on die.)
Basic dimensions of American National Standard Taper Pipe Thread. NPT1
Nominal Pipe Size (NPT) 1/2 3/4
1 11/4 11/2 2
Nominal Pipe Size (NPT) 1/2 3/4
1 11/4 11/2 2
Length, L1 Plane tp L2 Plane External Thread (L2-L1) inch Thread 0.2137 2.99 0.2067 2.89 0.2828 3.25 0.2868 3.30 0.3035 3.49 0.3205 3.69
O.D. of Pipe (D) 0.840 1.050 1.315 1.660 1.900 2.375
Threads/in. (n) 14
0.07143
11.5
0.08696
Wrench Make-Up Length for Internal Thread Length (L3) inch Thread 0.2143 3 0.2609
Pitch of Thread (P)
Dia. (E3) 0.74504 0.95429 1.19733 1.54083 1.77978 2.25272
Handtight Engagement
Pitch dia. at beginning of External Thread (Eo) 0.75843 0.96768 1.21363 1.55713 1.79609 2.26902
Vanish Thread (V) inch Thread 0.2478 3.47 0.3017
Effective Thread, External
Length (L) inch
Threads
0.320 0.339 0.400 0.420 0.420 0.436
4.48 4.75 4.60 4.83 4.83 5.01
Length 4 (L2) Dia (E1) 0.77843 0.98887 1.23863 1.58338 1.82234 2.29627
Overall Length Nominal Complete External External Threads Thread (LA) Length (L5) Dia. (E5) 0.7815 0.3909 0.78286 0.7935 0.4029 0.99286 0.9845 0.5089 1.24543 1.0085 0.5329 1.59043 1.0252 0.5496 1.83043 1.0582 0.5826 2.30543
inch
Threads
0.5337 0.5457 0.6828 0.7068 0.7235 0.7565
7.47 7.64 7.84 8.13 8.32 8.70
Height of Thread (h) 0.05714
0.06957
Dia (E2) 0.79179 1.00179 1.25630 1.60130 1.84130 2.31630
Basic Minor Dia. Increase in at Small Dia./Thread End of (0.0625/n) Pipe (K0) 0.7013 0.00446 0.9105 1.1441 1.4876 0.00543 1.7265 2.1995
NOTE: The basic dimensions of the American National Standard Taper Pipe Thread are given in inches to four to five decimal places. While this implies a greater degree of precision than is ordinarily attained, these dimensions are the basis of gauge dimensions and are so expressed for the purpose of eliminating errors in computations. Gauge Thread 11/2" NPT 1" NPT 1/2" NPT
Dry Torque (ft. lbs.) Procedure 125-225 -[170-306 Nm] 75-150 DS-629 [102-200 Nm] 30-80 Nm -[40-108 Nm]
Gauge Thread 11/4" NPT 3/4" NPT
--
Dry Torque (ft. lbs.) 100-200 [136-270 Nm] 50-100 [68-136 Nm] --
Procedure DS-322 DS-996 --
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
GAUGES 115-793 NOTE: Check color stripe on O.D. of gasket for material. Senior = 2.06" [52,3] nominal diameter — Junior = 1.56" [39,6] nominal diameter
BLUE STRIPE = NEOPRENE RED STRIPE = BUNA-N BROWN STRIPE = VITON WHITE GASKET = TEFLON SPIRAL WOUND TEFLON AND STAINLESS STEEL 5/16 – 24 screw – 30 to 60 In. Lb., [3,4 to 6,8 Nm] using a crossing pattern. 1/4 – 28 screw – 20 to 50 In. Lb., [2,3 to 5,6 Nm] using a crossing pattern.
#10 screw – 20 to 25 In. Lb. [2,3 to 2,8 Nm] using a crossing pattern.
Replacing Dials 115-794
Advanced Matrix TwinSite™
Junior™ TwinSite™
MFR# ROG0040-00414 ROG0040-00415
DESCRIPTION Screw Head, Junior Screw Head, Senior
WEBB# 184067 184068
ROG0015-00004 ROG0015-00007
Gasket, Senior Gauge Gasket, Mounting Jr.
184063 184064
ROG5323S01749 ROG5323S01789 ROG5323S01813
Dial, Junior W/5-1749 Dial, Junior f/331/2 Underground ASME Rep.
184077 184098 184078
The VICTOR Propane Equipment Catalog
Junior™ Direct Reading
GAUGE S
Replacing Gaskets
93
G A S P I P E, T U B I N G & F I T T I N G S
94
GAS PIPE, TUBING & FITTINGS Flexible Gas Tubing PART NUMBER
SIZE
PKG. QTY
WEBB#
Corrugated Stainless Steel 300 Series with Polyethylene Jacket TRPFGP-SS4-375-100 3/8” 100’ reel 216967 TRPFGP-SS4-375-250
3/8”
250’ reel
216966
TRPSS4-500-50
1/2”
50’ reel
250003
TRPFGP-SS4-500-100
1/2”
100’ reel
219618
TRPFGP-SS4-500-250
1/2”
250’ reel
87389
TRPSS4-750-50
3/4”
50’ reel
250003
TRPFGP-SS4-750-100
3/4”
100’ reel
219619
TRPFGP-SS4-750-250
3/4”
250’ reel
87390
TRPSS4-100-50
1”
50’ reel
25000
TRPFGP-SS4-100-180
1”
180’ reel
87391
TRPFGP-SS4-100-180
1”
180’ reel
87391
TRPSS4-125-50
11/4”
50’ reel
250001
TRPFGP-SS4-125-150
11/4”
150’ reel
205453
TRPFGP-SS4-150-150
11/2”
150’ reel
219620
TRPFGP-SS4-200-150
2”
150’ reel
219621
Description/Dimensions
Part Number FGP-SS4-375 FGP-SS4-500 FGP-SS4-750 FGP-SS4-1000 FGP-SS4-1250 FGP-SS4-1500 FGP-SS4-2000 3/8" 1/2" 3/4" Size (inch) 1" 11/4" 11/2" 2" EDH (AGA Size) 15 19 25 31 37 46 62 Jacket O.D. (max.) .668 .868 1,108 1.38 1,665 1,920 2,590 Inside Dia. (nom) .440 .597 820 1.040 1,290 1,525 2,060 Wall Thickness (in.) .01 .01 .01 .01 .012 .012 .012
* EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity. This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
Underground Gas Pipe PART NUMBER
SIZE
PKG. QTY
WEBB#
TRPUG375-100 TRPUG500-100 TRPUG750-100 TRPUG100-100 TRPUG125-100 TRPUG500-200 TRPUG150-100 TRPUG150-200 TRPUG200-100
3/8”
100’ coil 100’ coil 100’ coil 100’ coil 100’ coil 200’ coil 100’ coil 200’ coil 200’ coil
216985 216986 216987 216988 216989 241888 S720800 242755 242756
1/2” 3/4”
1” 11/4” 11/4” 11/2” 11/2” 2”
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
GAS PIPE, TUBING & FITTINGS
95 G A S P I P E, T U B I N G & F I T T I N G S
AutoFlare® Fittings Brass Fitting AutoFlare Insert
Straight Mechanical Fittings, Reducing Fittings
Straight Fitting
Reducing Fitting
PART NUMBER
TYPE
SIZE
PKG. QTY.
TRPFGP-FST-375 TRPFGP-FST-500 TRPFGP-FST-750 TRPFGP-RST750-500 TRPFGP-FST-1000 TRPFGP-RST1000-750 TRPFGP-FST-1250 TRPFGP-FST-1500 TRPFGP-FST-2000
Straight Straight Straight Reducing Straight Reducing Straight Straight Straight
3/8” (1/2” NPT) 24/box 1/2” 3/4” 3/4”-1/2” NPT 1” 1”-3/4” NPT 11/4” 11/2” 2”
24/box 24/box 16/box 16/box 16/box 6/box 4/box 4/box
WEBB# 216968 87393 87394 219624 87395 219625 205454 219622 219623
Termination Mount, Meter Termination Termination Mount
90° Termination Mount
Meter Termination
Flange Mount Fitting
90° Elbow Flange Mount
Mounting Bracket
PART NUMBER
TYPE
PKG. QTY. SIZE
WEBB#
TRPFGP-TM-375 TRPFGP-TM-500 TRPFGP-TM-750 TRPFGP-TM-1000 TRPFGP-90TM-375 TRPFGP-90TM-500 TRPFGP-MT6-500 TRPFGP-MT12-500 TRPMT6-750
Termination Mount Termination Mount Termination Mount Termination Mount 90° Termination Mount 90° Termination Mount 6” Meter Termination 12” Meter Termination 6” Meter Termination
12/Box 12/Box 8/Box 8/Box 8/Box 8/Box 1 ea. 1 ea. 1 ea.
217405 217406 217407 219626 217401 217402 246855 246856 250428
Flange Fittings TRPFGP-FF-375
Iron Flange
12/box
3/8”
216975
TRPFGP-FF-500 TRPFGP-FF-750 TRPFGP-FF-1000 TRPFGP-FF-1250 TRPBFF-375 TRPBFF-500 TRPBFF-750 TRPBFF-1000 TRPFGP-BFF-114 TRPFGP-ELLS-375 TRPFGP-ELLS-500
Iron Flange Iron Flange Mount Iron Flange Mount Iron Flange Mount Brass Flange Brass Flange Brass Flange Brass Flange Flange Bracket 90° Elbow Flange Mount 90° Elbow Flange Mount
12/box 8/box 8/box 4/box
1/2”
87398 87399 87376 216976 153621 216963 216964 216965 222077 216981 216982
3/8” 1/2” 3/4”
1” 3/8” 1/2” 1/2” 1/2” 3/4”
3/4”
1” 11/4”
—
3/8”
—
1/2”
—
34”
—
1” All
1 ea. 8/box 8/box
3/8” 1/2”
TracPipe by Pipe Outlet
TracPipe by TracPipe Outlet PART NUMBER
TYPE
SIZE
TRPFGP-TF500-T500 TRPFGP-TF750-T750 TRPFGP-TF1000T1000 TRPFGP-TF750-T500 TRPFGP-TF1000-T500 TRPFGP-CPLG-375 TRPFGP-CPLG-500 TRPFGP-CPLG-750 TRPFGP-CPLG-1000
Tee Tee Tee Tee Tee Coupling Coupling Coupling Coupling
1/2” x 1/2” 14/box
PKG. QTY WEBB#
3/4” x 3/4” 12/box
253452 222079
1” x 1” 10/box 1/2” x 3/4” — 1” x 3/4” — 3/8” 24/box 1/2” 24/box 3/4” 16/box 1” 16/box
222081 222082 216977 216978 216979 216980
The VICTOR Propane Equipment Catalog
PART NUMBER
TYPE SIZE
TRPT500-500 TRPT750-750 TRPT750-500 TRPT1000-1000
Tee Tee Tee Tee
Tee
WEBB#
1/2” FIP
222078 222084 3/4” x 1/2” FIP S661838 1” FIP 222080 3/4” FIP
Coupling
TacPipe by Pipe Outlet Tee
G A S P I P E, T U B I N G & F I T T I N G S
96
GAS PIPE, TUBING & FITTINGS TracPipe Accessories Spare Split Rings
Full Striker Plate
Half Striker
PART NUMBER SIZE
WEBB#
TRPRING-375 TRPRING-500 TRPRING-700
222083 242572 242210
3/8” Spare 1/2” Spare 3/4” Spare
Striker Plates
Quarter Striker
PART NUMBER
DESCRIPTION
SIZE
PKG. QTY
WEBB#
TRPFGP-SP-025 TRPFGP-SP-050 TRPFGP-SP-100
Quarter Striker Plate Half Striker Plate Full Striker
3” x 2” 3” x 7” 3” x 12”
500/box 100/box 50/box
87381 87380 87379
Floppy Galvanized Steel Conduit Floppy Strip Wound Conduit
Coated Manifold
PART NUMBER
DESCRIPTION
SIZE
PKG. QTY WEBB#
TRPFGP-FPY-375-50 TRPFGP-FPY-500-50 TRPFGP-FPY-750-50 TRPFGP-FPY-1000-50 TRPFPY-1250 TRPFPY-1500
Floppy Fits 3/8” Floppy Fits 1/2” Floppy Fits 3/4” Floppy Fits 1” Floppy Fits 11/4” Floppy Fits 2”
3/4”
50’ Coil 50’ Coil 25’ Coil 25’ Coil 25’ Coil 25’ Coil
1” 11/4” 11/2” 2” 21/2”
216969 216970 216971 216972 205456 216973
Manifolds
Manifold Bracket
PART NUMBER DESCRIPTION
SIZE
PKG. QTY WEBB#
TRPFGP-MI-PC Coated Manifold 3/4” x 1/2” x 1/2”(4) 1 ea. TRPFGP-MB2 Manifold Bracket * 1 ea. TRPTERM-BRAC Flange L Bracket * 1 ea. TRPP-LC Load Center w/Bracket * 1 ea.
246854 217403 222077 216983
Load Center w/Bracket
Underground TracPipe Accessories
Shrink Cuffs
Vent Tees
Shrink Cuffs
Vent Tees
(Two required for each run)
(Use when required by local codes)
PART NUMBER SIZE
WEBB#
PART NUMBER SIZE
WEBB#
TRPHST-38 TRPHST-12 TRPHST-34 TRPHST-1 TRPHST-300 TRPHST-350-6 TRPHST-2
216990 216991 216992 216993 216994 242757 242758
TRPVT-38 TRPVT-12 TRPVT-34 TRPVT-1 TRPVT-200 TRPVT-112 TRPVT-2
216995 216996 216997 216998 216999 242759 242760
3/8” 1/2” 3/4”
1” 11/4” 11/2” 2”
TracPipe Tools PART NUMBER DESC. TRPTC-151 TRPTC-152
Pipe Wrap
3/8” 1/2” 3/4”
1” 11/4” 11/2” 2”
Underground TracPipe Pipe Wrap WEBB#
Tube Cutter for 3/8” – 11/4” 242814 Tube Cutter for 11/4” – 2” 216984
PART NUMBER
DESC.
WEBB#
TRP915-10H-12
Yellow Outdoor
242814
Tube Cutter
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
GAS PIPE, TUBING & FITTINGS
97
For Natural Gas and Liquefied Petroleum Gas Copper has proven to be reliable and economical source for interior natural gas and liquefied petroleum installations for over 25 years. It’s use has introduced vertical subdivision concepts, individual metering and new add-on markets.
Safer Installation for Gas
Copper’s demand ranges from single-family dwellings to row houses to multi-story apartments. Within these dwellings, gas can be a source for furnaces, room heaters, air conditioning units, gas-fired heating boilers and domestic hot water heaters. Gas also economizes the use of cooking ranges, clothes dryers, gas fireplaces, gas barbeques and decorative gas lamps.
Easy to Install • No additional training required for installation • Flexible • Easy to join • Compact size • Requires smaller and fewer tools than steel pipe • Cleaner than threaded steel pipe
MFR# SIZE WEBB# General Purpose, Yellow Coating KMCPC38OD50 3/8” x 50” 190668 KMCPC12OD50 1/2” x 50” 190669 KMCPC58OD50 5/8” x 50” 190670 KMCPC380D100 3/8” x 100” 190671 KMCPC120D100 1/2” x 100” 190672 KMCPC580D100 5/8” x 100” 190673 KMCPC5380D250 3/8” x 250” 191023 KMCPC120D250 1/2” x 250” 191024 KMCPC580D250 5/8” x 250” 245837 Oil Tech, Orange Coating KMC38X50CTD 3/8” x 50” KMC12X50CTD KMC38X100CTD KMC12X100CTD Type “L” KMCPC38L60 KMCPC12L60 KMCPC58L60 KMCPC38L100 KMCPC12L100
Can Gas-Tec be used underground? Yes, our material can be direct buried. In Canada, GasTec G/Gas is currently the only tubing that can be used both above and below ground without any modification. In the United States, most areas allow Gas-Tec Refrigeration grade or Type “L” tubing to be buried, but we recommend our Gas-Tec type “L” (G/Gas) due to the heavier wall thickness on most sizes.
201445
1/2” x 50”
213315 3/8” x 100” 201446 1/2” x 100” 213316
How cost effective is Gas-Tec tubing? Gas-Tec is one of the most cost-effective flexible tubing products available on the market. Combined with the labor savings of installing copper, our product is easily joined using standard flare fittings or by brazing with conventional copper couplings. Underground installations require no transitions or risers and this alone can save you 25-50% over the use of plastic piping and conventional risers on runs under 75’.
3/8” x 60”
190674 190675 5/8” x 60” 190676 3/8” x 100” 191020 1/2” x 100” 191021 1/2” x 60”
OUTSIDE DIAMETER 3/8” G/Gas 1/2” G/Gas 5/8” G/Gas 3/4” G/Gas 7/8” G/Gas
WALL THICKNESS .030” .035” .040” .042” .045”
STANDARD LENGTHS* 30’ 60’ 100’ 250’ 30’ 60’ 100’ 250’ 30’ 60’ 100’ 250’ 30’ 60’ 100’ 30’ 60’ 100’
* Custom sizes available upon request
General Purpose, ASTM B68/B280 Refrigeration OUTSIDE DIAMETER 3/8” 1/2” 5/8”
WALL THICKNESS .032” .032” .035”
Cost Efficient • Most economical line-marked tubing on the market • Minimal labor costs due to quick and easy installation • No on-site sleeving required for underground gas lines Recyclable • Copper is fully recyclable
Type L-G/Gas, ASTM B88/B837 NOMINAL SIZE 1/4” L 3/8”L 1/2”L 5/8”L 3/4”L
Easy to Identify • Permanent yellow polyethylene coating • Continuous line marking • Traceable back to origin of manufacturing • Mill test reports available upon request
STANDARD LENGTHS* 25’ 50’ 100’ 250’ 25’ 50’ 100’ 250’ 25’ 50’ 100’ 250’
The VICTOR Propane Equipment Catalog
G A S P I P E, T U B I N G & F I T T I N G S
Copper Tubing
G A S P I P E, T U B I N G & F I T T I N G S
98
GAS PIPE, TUBING & FITTINGS
Yellow Plastic Gas Pipe
Dayco Bulk Hose
Pressure rated PE 2406 IPS and CTS Gas pipe for natural gas distribution and service lines.
Spiral Reinforced
MFR# IPS Sizes YGP12SDR93-50 YGP12SDR93-100 YGP12SDR93-150 YGP12SDR93-200 YGP12SDR93-500 YGP34SDR11-50 YGP34SDR11-100 YGP34SDR11-150 YGP34SDR11-500 YGP1SDR11-100 YGP1SDR11-150 YGP1SDR11-200 YGP1SDR11-500 YGP114SDR10-100 YGP114SDR10-150 YGP114SDR10-200 YGP114SDR11-100 YGP114SDR11-150 YGP114SDR11-200 YGP114SDR11-500 YGP112DR11-150 YGP112SDR11-500 YGP2SDR11-50 YGP2SDR11-100 YGP2SDR11-150 YGP1DR11-200 *YGP3SDR11-100 *YGP3SDR115-200 *YGP3SDR11-500 *YGP4SDR115 * Special Order CTS Sizes YGP12CTS090-100 YGP12CTS090-200 YGP12CTS090-500 YGP12CTS099-50 YGP12CTS099-100 YGP12CTS099-300 YGP1CTS099-75 YGP1CTS099-150 YGP1CTS099-200 YGP1CTS099-300 YGP1CTS099-500 YGP1CTS102-75 YGP1CTS102-150
DESCRIPTION WEBB# 1/2” IPS x 50’
165570
1/2” IPS x 100’ 165738 1/2” IPS x 150’ 165739 1/2” IPS x 200’ 165740
Certified & Tested
Series 7132 LP Gas Hose
Features a smooth, abrasion resistant cover and the flexibility of the 4 spiral reinforcements result in a hose that is easier to handle and glides smoothly over any surface. • Tube: Black Nitrile
1/2” IPS x 500’ 183399
• Cover: Perforated Black Neoprene
3/4” IPS x 50’
• Reinforcement: Multiple Textile Braids
165571
3/4” IPS x 100’ 165741 3/4” IPS x 150’ 165742 3/4” IPS x 500’ 183429
1” IPS x 100’ 165572 1” IPS x 150’ 165743 1” IPS x 200’ 165744 1” IPS x 500’ 183430 11/4” IPS x 100’ 165574 11/4” IPS x 150’ 165747 11/4” IPS x 200’ 165748 11/4” IPS x 500’ 165573 11/4” IPS x 150’ 165745 11/4” IPS x 200’ 165746 11/4” IPS x 500’ 183431 11/2” IPS x 150’ 165575 11/2” IPS x 500’ 183432 2” IPS x 15’ 165776 2” IPS x 100’ 165749 2” IPS x 150’ 165750 2” IPS x 200’ 165751 3” IPS x 100’ S790541 2” IPS x 500’ 165752 3” IPS x 500’ 165752 4” IPS 165579
1/2” CTS x 100’ 193140 1/2” CTS x 200’ 193141 1/2” CTS x 500’ 183524 1/2” CTS x 50’
202853 1/2” CTS x 100’ 165581 1/2” CTS x 300’ 203239 1” IPS x 75’ 165762 1” IPS x 150’ 165754 1” IPS x 200’ 165755 1” IPS x 300’ 165756 1” IPS x 500’ 183525 1” IPS x 75’ 165763 1” IPS x 150’ 165758
• Temp. Range: -50°F to 180°F MFR# HOS1X125WFIT HOS34X150WFIT HOS1X150WFIT HOS1X175WFIT
DESC. 1” x 125’ 3/4” x 150’ 1” x 150’ 1” x 175’
WEBB# 185593 s652406 185595 206544
Drip Leg Packages MFR# DLKDL-6-3 DLKDL-8-3 DLKDL-8-6 DLKDL-12-3 DLKDL-12-6
SIZE 3/8” x 3” 1/2” x 3” 1/2” x 6” 3/4” x 3” 3/4” x 6”
WEBB# 184977 184978 184979 184975 184976
Standard Copper Tubing WEBB# MFR# K Tubing 2525 C/T14K60 2526 C/T38K60 2539 C/T12K60 111921 C/T58K60 L Tubing 2551 C/T14L60 2552 C/T38L60 2553 C/T12L60 Refrigeration Tubing 2578 C/T18OD 2579 C/T316OD 2580 C/T14OD 2581 C/T516OD 2582 C/T38OD 2583 C/T12OD 2584 C/T58OD
WEBB#
MFR#
187618 191720 150326 S123505
C/T14K100 C/T38K100 C/T12K100 C/T58K100
190615 190614 91639
C/T14L100 C/T38L100 C/T12L100
92012 58835 150328 58836 58837
C/T14OD100 C/T38OD100 C/T516OD100 C/T12OD100 C/T58OD100
See the sizing table on Page 97
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
GAS PIPE, TUBING & FITTINGS
99
Lower Installation Costs — Fewer Repairs Over Time The LycoFit® connection system by Lyall, which requires no pipe preparation or special training, is much easier and faster to install compared to other mechanical fittings, electrofusion, and thermal fusion methods. Even more important is that installation failures due to bad pipe cuts, poor fusion, and weak connections are eliminated in the process. Add to that the durability of Lyall chemically resistant fittings and you will no longer have to concern yourself with re-installation due to typical joint failures.
Residential Application
Lyall provides a wide variety of product sizes and configuration to meet residential needs.
LYCOFIT® Mechanical Fittings
• 100% leak-proof, easy to install • Cost effective, maintenance free joining system • Unprecedented performance levels and proven reliability • Excellent durability resistant to harsh chemicals and cracking • Simple installation, no fusion equipment required • No measuring or calculating required • Absolutely no slippage or pull-out
LYCOFIT® is a mechanical fitting for connecting underground Polyethylene (PE) gas piping systems. Lyall offers over 900 configurations allowing for varied installation requirements. Patented 100% Leak-Proof Design The LYCOFIT® fitting takes advantage of the natural sealing properties of the PE pipe, in a superior patented design that uses a barbed spigot to seal the inside diameter (ID) of the PE gas pipe, and a completion sleeve that provides the force necessary for a leakproof, reliable connection every time. By using the polyethylene as the gasket material, this assures a positive seal between the coupling and the pipe regardless of the outside condition of the pipe. The system eliminates the use of O-rings and rubber gaskets that could leak on scratched pipe or deteriorate under adverse conditions like exposure to chemicals. Compact LYCOFIT® designs allow for installation in confined spaces. Eliminates Pull-Out The design provides a connection so strong that it provided enough gripping power to eliminate pull-out 100% of the time. In ASTM Quick Burst and Tensile Testing, PE Pipe fails before the LYCOFIT® coupling every time! Instant Visual Check LYCOFIT® provides the installer with a full visual quality check — first “pipe-on” and the “sleeve on” in each installation for a gas tight connection.
The VICTOR Propane Equipment Catalog
G A S P I P E, T U B I N G & F I T T I N G S
R. W. Lyall Propane Piping Systems
G A S P I P E, T U B I N G & F I T T I N G S
100 GAS PIPE, TUBING & FITTINGS R. W.Lyall Propane Piping Systems (cont.) LYCOFIT® Mechanical Fittings MFR# DESCRIPTION PE Pipe to Copper Tube Adapter
WEBB#
MFR# 3-Way Tee Couplings
DESCRIPTION
WEBB#
LYCLC010B-3TR LYCLC030B-3TR LYCLC050W-3TR LYCLC060Y-3TR LYCLC070Y-3TR LYCLC090Y-3TR LYCLC080X-3TR LYCLC200Y-3TR 90° Elbow Couplings
1/2” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 11/2” IPS 2” IPS
179029 179031 183470 183467 179037 183520
LYCLC375010B-GCR 3/8” O.D. Flare x 1/2” CTS 179091 LYCLC500010B-GCR 1/2” O.D. Flare x 1/2” CTS 179093 Double End Couplings
LYCLC010B-DER LYCLC030B-DER LYCLC030D-DER LYCLC050W-DER LYCLC060Y-DER LYCLC070Y-DER LYCLC080X-DESR LYCLC090Y-DESR LYCLC200Y-DESR Stop & Go Couplings
LYCLC010B-SGR LYCLC050W-SGR LYCLC060Y-SGR Reducer Couplings
LYCLC010B010A-RR LYCLC030D010B-RR LYCLC030D050W-RR LYCLC030D060Y-RR LYCLC040B010B-RR LYCLC050W010B-RR LYCLC060Y010B-RR LYCLC060Y050W-RR LYCLC070Y010B-RR LYCLC070Y050W-RR LYCLC070Y060Y-RR LYCLC070Y030B-RR LYCLC070Y030D-RR LYCLC080X060Y-RR LYCLC080X070Y-RR LYCLC090Y060Y-RR LYCLC090Y070Y-RR LYCLC090Y080X-RR LYCLC200Y070Y-RR LYCLC200Y080X-RR LYCLC200Y090Y-RR
1/2” CTS 1” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 11/2” IPS 2” IPS
183448 179004 179005 183453 183449 183450 183451 179012 183452
1/2” CTS 1/2” IPS 3/4” IPS
179025 179027 179028
1/2” CTS x 1/2” CTS 1” CTS x 1/2” CTS 1” CTS x 1/2” IPS 1” CTS x 3/4” IPS 11/4” CTS x 1/2” CTS 1/2” IPS x 1/2” CTS 3/4” IPS x 1/2” CTS 3/4” IPS x 1/2” IPS 1” IPS x 1/2” CTS 1” IPS x 1/2” IPS 1” IPS x 3/4” IPS
1” IPS x 1” CTS 1” IPS x 1” CTS 11/4” IPS x 3/4” IPS 11/4” IPS x 1” IPS 11/2” IPS x 3/4” IPS 11/2” IPS x 1” IPS 11/2” IPS x 11/4” IPS 2” IPS x 1” IPS 2” IPS x 11/4” IPS 2” IPS x 11/2” IPS
179063 179066 179067 179068 179069 179073 193507 179074 179077 182465 179080 179081
179084
LYCLC010B-ELR LYCLC030B-ELR LYCLC060Y-ELR LYCLC070Y-ELR LYCLC080X-ELR LYCLC090Y-ELR Repair Couplings
LYCLC080X-DER LYCLC200Y-DER End Caps
1/2” CTS 1” CTS 3/4” IPS 1” IPS 11/4” IPS 11/2” IPS
11/4” IPS 2” IPS
LYCLC010B-ECR 1/2” CTS LYCLC050W-ECR 1/2” IPS LYCLC060Y-ECR 3/4” IPS LYCLC070Y-ECR 1” IPS LYCLC080X-ECR 11/4” IPS LYCLC200Y-ECR 2” IPS Steel Pipe to PE Pipe Transitions LYCLC050S010B-SPB LYCLC050S050W-SPB LYCLC060S060Y-SPB LYCLC070S070Y-SPB LYCLC080S080X-SPB LYCLC090S090Y-SPB LYCLC200S200Y-SPB
1/2” NPT x 1/2” CTS 1/2” NPT x 1/2” IPS 3/4” NPT x 3/4” IPS
1” NPT x 1” IPS 11/4” NPT x 11/4” IPS 11/2” NPT x 11/2” IPS 2” NPT x 2” IPS
183469
179040 179042 183458 183459 183460
179086 179087
179014 183457 179021 183455 179023 179024
183510 183511 183512 179062
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
GAS PIPE, TUBING & FITTINGS
101
Lycofit® Mechanical Tapping Tees MFR# DESCRIPTION Mechanical Tapping Tees
Lyall Risers
WEBB#
LC080010B-TT 11/4” IPS x 1/2” CTS 179131 LC080030B-TT 11/4” IPS x 1” CTS LC080030D-TT 11/4” IPS x 1” CTS 179133 LC080040B-TT 11/4” IPS x 11/4” CTS LC080040H-TT 11/4” IPS x 11/4” CTS LC080050W-TT 11/4” IPS x 1/2” IPS 216004 LC080060Y-TT 11/4” IPS x 3/4” IPS 179141 LC080070Y-TT 11/4” IPS x 1” IPS 179143 LC200010B-TT 2” IPS x 1/2” CTS 198639 LC200030B-TT 2” IPS x 1” CTS 216006 LC200030D-TT 2” IPS x 1” CTS LC200040B-TT 2” IPS x 11/4” CTS LC200040H-TT 2” IPS x 11/4” CTS LC200050W-TT 2” IPS x 1/2” IPS 179154 LC200060Y-TT 2” IPS x 3/4” IPS 179156 LC200070Y-TT 2” IPS x 1” IPS 179157 Test Cap, Mechanical Tapping Tees LCTESTCAP Fits all Lyall Mechanical Tapping Tees Wrench, “T” Handled
LYCLCT
MFR# DESCRIPTION Anodeless 90° Bend Rigid Riser
WEBB#
LYCSTDLY050010T LYCSTDLY060010T LYCSTDLY060050T LYCSTDLY060060T LYCSTDLY070010T LYCSTDLY070030T LYCSTDLY070050T LYCSTDLY070060T LYCSTDLY070070T LYCSTDLY080080T LYCSTDLY090090T LYCSTDLY200200T Anodeless Flexible Riser
193302 192989 180062 180063 193893 193894 193895 193896 183406 180066 193897 193898
1/2” 3/4” 3/4” 3/4”
NPT x 1/2” CTS NPT x 1/2” CTS NPT x 1/2” IPS NPT x 3/4” IPS 1” NPT x 1/2” CTS 1” NPT x 1” CTS 1” NPT x 1/2” IPS 1” NPT x 3/4” IPS 1” NPT x 1” IPS 11/4” NPT x 11/4” IPS 11/2” NPT x 11/2” IPS 2” NPT x 2” IPS
LYCSTDLY060010FX-T 3/4” NPT x 1/2” CTS LYCSTDLY060050FX-T 3/4” IPS x 1/2” IPS LYCSTDLY060060FX-T 3/4” IPS x 3/4” IPS LYCSTDLY070010FX-T 1” NPT x 1/2” CTS LYCSTDLY070050FX-T 1” NPT x 1/2” IPS LYCSTDLY070060FX-T 1” IPS x 3/4” IPS Anodeless LPG Flexible Tank Risers
192494 192628 192630 192631 192632 192634
LYCSTDLY050010FX-PGS 1/2” NPT x 1/2” CTS LYCSTDLY050050FX-PGS 1/2” NPT x 1/2” IPS LYCSTDLY060060FX-PGS 3/4” NPT x 3/4” NPT
252451 252452 252456
for Lycofit® Mechanical Tapping Tee Cutter
Transition Fittings MFR# DESCRIPTION Threaded Steel End
WEBB#
Lyall Meter Manifolds LYCLT050S010B-BT LYCLT050S050W-BT LYCLT060S060Y-BT LYCLT070S030B-BT LYCLT070S30D-BT LYCLT070S070Y-BT LYCLT080S080X-BT LYCLT090S090Y-BT LYCLT200S200Y-BT
1/2” NPT x 1/2” CTS 1/2” NPT x 1/2” IPS 3/4” NPT x 3/4” IPS
1” NPT x 1” CTS 1” NPT x 1” CTS 1” NPT x 1” IPS 11/4” NPT x 11/4” IPS 11/2” NPT x 11/2” IPS 2” NPT x 2” IPS
198865 202405 198870 215614 202399 202400
MFR# DESCRIPTION Manifolds, Multi-Meter
WEBB#
LYCMMB018T2-001 1” NPT x 1/2” NPT, 2 Outlets LYCMMB036T2-001 1” NPT x 1/2” NPT, 4 Outlets LYCMMBA18T2-001 1” NPT x 3/4” NPT, 2 Outlets LYCMMBA36T2-001 1” NPT x 3/4” NPT, 4 Outlets LYCMMCB28.5TC2-001 11/4” NPT x 1” NPT, 2 Outlets LYCMMCB46.5TC3-001 11/4” NPT x 1” NPT, 3 Outlets Manifolds, Corrugated Stainless Steel Tubing (CSST)
252458 252459 252460 252461 252462 252463
LYCMIP0600600504PD 3/4” NPT x 1/2” NPT, 4 Outlets Brackets for Risers & Manifolds
252464
Lyall Polyethylene Ball Valves Available through special order Sizes , 1/2” CTS — 2” IPS
LYCBRKL-6
The VICTOR Propane Equipment Catalog
6” Wall Mount
252457
G A S P I P E, T U B I N G & F I T T I N G S
R. W.Lyall Propane Piping Systems (cont.)
G A S P I P E, T U B I N G & F I T T I N G S
102 GAS PIPE, TUBING & FITTINGS R. W.Lyall Propane Piping Systems (cont.) LYCOFIT® Installation Tools Tools that make every job quick and easy LYCOFIT® Tools allow for quick and easy installation of LYCOFIT® fittings. These tools provide perfect alignment and precision installment each and every time, without special training or time consuming measurements required. Quick Ratchet Press (QRP-100) Accessories for QRP Tool The QRP-100 is a light weight, durable, single MFR# DESCRIPTION ratchet field assembly tool that installs all Pipe Jaw Vise-Grip LYCOFIT® couplings from 1/2” CTS/IPS through 1” CTS. Dual Quick Ratchet Press (QRP-200) Designed for manual installations, the dual ratchet design of the QRP-200 makes it simple to install of medium to large sized piping systems. Installs all LYCOFIT® couplings from 3/4” IPS through 2” IPS. MFR# LYCQRP-100 LYCQRP-125 LYCQRP-200
DESCRIPTION WEBB# 1/2” CTS — 1” IPS 179095 1/2” CTS — 11/4” CTS 3/4” CTS — 2” IPS
LYCAPJ010 LYCAPJ050 LYCAPJ060 LYCAPJ070 LYLF-BOXQRP
1/2” CTS
183540 179097 1” CTS / 3/4” IPS 179098 11/4” CTS / 1” IPS 183518 Tool Box for QRP-100 179100 3/4” CTS / 1/2” IPS
Time is money To make sure you do each operation quickly, easily, and properly every time Lyall offers the right tools to assure the job is done correctly.
Accessories for LAP Tool Large Auto Press (LAP-100) DESCRIPTION This heavy duty hydraulic tool is designed to MFR# provide thousands of worry free installations Pipe Clamp quickly and easily. Installs 11/4”, 11/2” and 2” IPS LYCOFIT® couplings. MFR# DESCRIPTION Hydraulic Tool & ENERPAC™ LYCLAP100 11/4” IPS — 2” IPS LYCAHP100 ENERPAC™
WEBB# 183440 183535
WEBB#
LYCAPJ080-1 Standard – 11/4” IPS LYCAPJ090 Standard – 11/2” IPS LYCAPJ200-1 Standard – 2” IPS LYCAPJ200PB-01Pull-Back – 2” IPS LYCLF-BOXLAP Tool Box for LAP-100
WEBB#
179105 193027 179105 179108 179109
LycoRing® Lightweight, disposable plastic ring that easily slips over the PE pipe and securely grips the pipe while inserting the pipe onto the LYCOFIT® spigot. The LycoRing® is included with the matching LYCOFIT® fitting and can be used with all LYCOFIT® configurations that use QRP and LAP tools, including tapping tee outlets. LycoRing® is provided with each LYCOFIT® fitting and eliminates the need for additional gripping tools to install fittings. Specifications • Meets or exceed all requirements for the Categorization of Mechanical Fittings within ASTM D2513-90c Category 1, and requirements from the Code of Federal Regulations, Title 49 Part 192.281 and 192.283. • Meets or exceeds NFPA-58 – 1002, DOT and ISO requirements. • Listed with IAPMO/UPS and CSA • Conforms to the Mechanical Fitting Specification as defined in ASTM F 1924. A complete set of specifications and test results for the product are available upon request.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
GAS PIPE, TUBING & FITTINGS Marshall Brass Type 1 RV Pigtails
Extend-A-Flow™ #535-00
40408
MARSHALL BRASS
The Extend-A-Flow™ Kit allows the RV owner to fuel small, portable, high pressure propane appliances such as camp stoves, lanterns and table top grills directly from the fuel supply on their RV or cottage rather than using the small, expensive, throwaway propane cylinders that are designed to normally thread into these appliances. This kit includes a listed brass tee fitting, a twelve foot flexible hose and complete directions for installation, use and storage.
• UL-CGA listed thermoplastic pigtail • 1/4” ID high pressure assemblies • Type 1 ACME x 1/4” inverted flare 40408
40409 • UL-CGA listed thermoplastic pigtail • 1/4” ID high pressure assemblies • Type 1 ACME x 1/4” MNPT 40409
Extend-A-Stay™ #536-00, #537-00 Extend-A Stay™ Kits allow motorhome owners to hook up to an auxiliary propane cylinder or tank so they can stay where they want for as long as they want without having to periodically move their rig to fill the propane tank. The standard Extend-A-Stay™ Kit 536-00 includes illustrated instructions for installation and proper use, a listed brass tee fitting, and a five foot flexible pigtail for hooking up the auxiliary tank or cylinder when parked for an extended stay. The deluxe Extand-A-Stay™ Kit 537-00 features an additional twelve foot Extend-A-Flow™ hose to let the owner enjoy the additional benefits of the Extend-A-Flow™ Kit, such as hooking up portable lanterns, camp stoves and table top grills. MFR# 535-00
DESC. Extend-A-Flow
536-00
Extend-A-Stay
537-00
Extend-A-Stay
WEBB#
Typical motorhome installation of Extend-A-Stay™ fitting with 5’ pigtail attached to reserve cylinder
The VICTOR Propane Equipment Catalog
MFR# MAB40408-15 MAB40408-20 MAB40409-15 MAB40409-20
SIZE 15” –1/4” Inv. Flare 20” – 1/4” Inv. Flare 15” – 1/4” MPT 20” – 1/4” MPT
WEBB# 217495 217497 217498 217499
Measuring for proper hose lengths: Measure from the inlet port of inlet fitting on the regulator to the outlet face of the cylinder valve and add one inch (1”). Allow proper routing of the hose to avoid kinking, pulling or contact with edges of the cylinder collar, rigid covers, walls, doors or other cylinder compartment structures. When measuring a Type 1 ACME flexible pigtail hose (Model 40408 or 40409), make an “over-all” measurement. measure from the end of the brass fitting at one end to the outermost edge of the green nut at the other end. Note: When retro-fitting, remember the length of the old POL type pigtail hose may be too long or too short. Always measure to determine the proper length.
G A S P I P E, T U B I N G & F I T T I N G S
Marshall Brass Propane Kits
103
CONNECTORS
104 CONNECTORS Dormont Stainless Steel Gas Connectors Residential Stainless Steel Gas Appliance Connectors Dormont’s complete line of flexible, corrugated, Supr-Safe® stainless steel connectors attach all types of gas appliances to gas utility lines. . .easily and safely. We carry the largest inventory in the business, with connectors ranging from 3/8” through 11/2” O.D. DESCRIPTION MFR# OD ID LENGTH THREAD TYPE WEBB# Water Heater, Gas Log, Space Heater, Connectors with Fittings DOR10-2121-12 3/8” 1/4” 12” 3/8 mnpt end 242096 DOR10-2121-18 3/8” 1/4” 18” 3/8 mnpt end 202067 DOR10-2121-24 3/8” 1/4” 24” 3/8 mnpt end 185424 DOR10-2121-30 3/8” 1/4” 30” 3/8 mnpt end 246859 DOR10-2121-36 3/8” 1/4” 36” 3/8 mnpt end 244976 DOR10-2121-48 3/8” 1/4” 48” 3/8 mnpt end 246858 DOR10-2222-12 3/8” 1/4” 12” 3/8 fnpt end 185448 DOR10-2222-18 3/8” 1/4” 18” 3/8 fnpt end 188283 DOR10-2222-24 3/8” 1/4” 24” 3/8 fnpt end 215474 DOR10-2222-36 3/8” 1/4” 36” 3/8 fnpt end 213164 DOR10-2222-48 3/8” 1/4” 48” 3/8 fnpt end 245962 DOR10-3131-18 3/8” 1/4” 18” 1/2 mnpt end 209723 DOR10-3131-36 3/8” 1/4” 36” 1/2 mnpt end 209724 Dryer Connections with Fittings DOR20-2122-18 1/2” 3/8” 18” 3/8 mnpt/fnpt 163856 DOR20-2122-30 1/2” 3/8” 30” 3/8 mnpt/fnpt 163857 DOR20-2122-36 1/2” 3/8” 36” 3/8 mnpt/fnpt 215814 DOR20-2222-36 1/2” 3/8” 36” 3/8 fnpt 192747 DOR20-2222-48 1/2” 3/8” 48” 3/8 fnpt 206103 DOR20-3122-12 1/2” 3/8” 12” 1/2 mnpt–3/8 fnpt 191054 DOR20-3122-18 1/2” 3/8” 18” 1/2 mnpt–3/8 fnpt 192608 DOR20-3122-24 1/2” 3/8” 24” 1/2 mnpt–3/8 fnpt 191055 DOR20-3122-36 1/2” 3/8” 36” 1/2 mnpt–3/8 fnpt 192613 DOR20-3122-48 1/2” 3/8” 48” 1/2 mnpt–3/8 fnpt 192610 DOR20-3122-60 1/2” 3/8” 60” 1/2 mnpt–3/8 fnpt 192611 DOR20-3122-72 1/2” 3/8” 72” 1/2 mnpt–3/8 fnpt 191056 DOR20-3131-12 1/2” 3/8” 12” 1/2 mnpt 166786 DOR20-3131-18 1/2” 3/8” 18” 1/2 mnpt 209421 DOR20-3131-24 1/2” 3/8” 24” 1/2 mnpt 166228 DOR20-3131-36 1/2” 3/8” 36” 1/2 mnpt 209422 DOR20-3131-48 1/2” 3/8” 48” 1/2 mnpt 166229 DOR20-3131-60 1/2” 3/8” 60” 1/2 mnpt 209423 DOR20-3132-36 1/2” 3/8” 36” 1/2 mnpt–1/2 fnpt 215815 DOR20-3132-48 1/2” 3/8” 48” 1/2 mnpt–1/2 fnpt 224158 Range Connectors with Fittings DOR30-3131-12 5/8” 1/2” 12” 1/2 mnpt 245963 DOR30-3131-18 5/8” 1/2” 18” 1/2 mnpt 218889 DOR30-3131-24 5/8” 1/2” 24” 1/2 mnpt 193511 DOR30-3131-30 5/8” 1/2” 30” 1/2 mnpt 201236 DOR30-3131-36 5/8” 1/2” 36” 1/2 mnpt 79589 DOR30-3131-48 5/8” 1/2” 48” 1/2 mnpt 179822 DOR30-3131-60 5/8” 1/2” 60” 1/2 mnpt 212867 DOR30-3131-72 5/8” 1/2” 72” 1/2 mnpt 218890 DOR30-3132-24 5/8” 1/2” 24” 1/2 mnpt–1/2 fnpt 204534 DOR30-3132-30 5/8” 1/2” 30” 1/2 mnpt–1/2 fnpt 163854 DOR30-3132-48 5/8” 1/2” 48” 1/2 mnpt–1/2 fnpt 163855 DOR30-3232-12 5/8” 1/2” 12” 1/2 fnpt 185449 DOR30-3232-18 5/8” 1/2” 18” 1/2 fnpt 68547 DOR30-3232-24 5/8” 1/2” 24” 1/2 fnpt 68548 DOR30-3232-36 5/8” 1/2” 36” 1/2 fnpt 68549 DOR30-3232-48 5/8” 1/2” 48” 1/2 fnpt 68692 DOR30-3232-60 5/8” 1/2” 60” 1/2 fnpt 185458 DOR30-3232-72 5/8” 1/2” 72” 1/2 fnpt 185460
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
CONNECTORS
105
MFR#
OD
ID
DESCRIPTION LENGTH THREAD TYPE
CONNECTORS
Dormont Stainless Steel Gas Connectors (Cont.) WEBB#
Range Connectors with End Fittings (cont.) DOR30-4141-18 5/8” 1/2” 18” 3/4 mnpt DOR30-4141-24 5/8” 1/2” 24” 3/4 mnpt DOR30-4141-36 5/8” 1/2” 36” 3/4 mnpt DOR30-4144-18 5/8” 1/2” 18” 3/4 mnpt–3/4" mnpt 90 DOR30-4144-24 5/8” 1/2” 24” 3/4 mnpt–3/4" mnpt 90 DOR30-4144-36 5/8” 1/2” 36” 3/4 mnpt–3/4" mnpt 90 DOR30-4144-48 5/8” 1/2” 48” 3/4 mnpt–3/4" mnpt 90 DOR30-4242-18 5/8” 1/2” 18” 3/4 fnpt DOR30-4242-24 5/8” 1/2” 24” 3/4 fnpt DOR30-4242-36 5/8” 1/2” 36” 3/4 fnpt DOR30-4242-48 5/8” 1/2” 48” 3/4 fnpt DOR30-4242-60 5/8” 1/2” 60” 3/4 fnpt DOR30-4242-72 5/8” 1/2” 72” 3/4 fnpt DOR40-4142-24 1” 3/4” 24” 3/4 mnpt–3/4 fnpt
213943 213944 197947 67650 55306 67651 67653 55305 67652 55307 55308 185457 185459 184568
End Fittings MFR#
DESCRIPTION
WEBB#
Dryer 20 Series (Fittings for 1/2” OD Connectors) DOR90-2032 1/2” fnpt for 1/2” OD (3/8” ID) DOR90-2042 3/4” fnpt for 1/2” OD (3/8” ID) Dryer 30 Series (Fittings for 5/8” OD Connectors) DOR90-3031 1/2” mnpt for 5/8” OD (1/2” ID) DOR90-3041 3/4” mnpt for 5/8” OD (1/2” ID) DOR90-3032 1/2” fnpt for 5/8” OD (1/2” ID) DOR90-3042 3/4” fnpt for 5/8” OD (1/2” ID)
246634 179505 185463 209028 185462 185461
Commercial Supr-Safe® Disconnect Gas Appliance Connectors – BPQ Series Stainless Steel corrugated hose, encased in a stainless steel braid, covered with a thick Super-Flex coating and fitted with an A Type “Push-to-Connect” quick disconnect coupling.
Dormont Moveable Connector with Push-to-Connect Quick Disconnect
MFR# DESCRIPTION WEBB# 1/2” Quick Couplings 1/2” x 36” 213236 DOR1650BPQ36 DOR1650BPQ48 1/2” x 48” 185437 1/2” x 60” 185439 DOR1650BPQ60 3/4” Quick Couplings DOR1675BPQ36 3/4” x 36” 185435 3/4” x 48” 185436 DOR1675BPQ48 3/4” x 60” 185438 DOR1675BPQ60 DOR1675BPQB48 3/4” x 48” (B Type) 204050 1” Quick Couplings DOR16100BPQ24 1” x 24” 216370 DOR16100BPQ36 1” x 36” 216371 DOR16100BPQ48 1” x 48” 192748 3/4” Quick Coupling with Restraining Device* DOR1675BPQR36 3/4” x 36” 163870 Restraining Device Coils DORRDC-36 for 36” Commercial flex 163862 DORRDC-48 for 48” Commercial flex 163863 * Also Available as kit with restraining device, Special Order
Connector Flow Capacity (Per ANSI Z21.24) Straight Length Capacity - BTU Per Hr (W) 0.64 Sp Gr, 1000 BTU Per Cu Ft (37.2 MJ/m3)Gas at 0.5 Inch Water Column (124 Pa) Pressure Drop
Series
Nominal Connector ID, Inch
1 foot (0.30 m)
11/2 foot (0.48 m)
2 foot (0.61 m)
21/2 foot (0.76 m)
3 foot (0.91 m)
4 foot (1.22 m)
5 foot (1.52 m)
6 foot (1.83 m)
10
1/4"
48,000 (14 067)
43,800 (12 837)
40,000 (11 723)
36,400 (10 668)
33,400 (9 789)
28,300 (8 294)
24,900 (7 297)
23,100 (6 770)
20
3/8"
102,000 (29 893) 93,1000 (27 285)
85,000 (24 911)
77,100 (22 742)
71,100 (20 837)
60,500 (17 731) 53,200 (15 591) 49,100 (14 390)
30
1/2"
180,000 (52 811) 164,200 (48 122)
150,000 (43 961)
136,000 (40 034) 125,000 (36 634) 106,000 (31 066) 93,200 (27 314) 86,000 (25 380)
The VICTOR Propane Equipment Catalog
FITTINGS
106 FITTINGS Brass Flare Fittings #42 Flare x Flare Union MFG# U2-2 U2-3 U2-4 U2-5 U2-6 U2-8 U2-10 U2-12 U2-14
CODE SAE18UN SAE316UN SAE14UN SAE516UN SAE38UN SAE12UN SAE58UN SAE34UN SAE78UN
#48 Flare x Male (MPT) Union SIZE 1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8
WEBB# 19795 19796 19797 19798 19799 19801 19802 19803 19804
#42R Flare x Flare Reducing Union MFG# CODE UR2-64 SAE38X14UN UR2-86 SAE12X38UN UR2-108SAE58X12UN UR2-84 SAE12X14UN UR2-106SAE58X38UN UR2-128SAE34X12UN
SIZE 3/8 x 1/4 1/2 x 3/8 5/8 x 1/2 1/2 x 1/4 5/8 x 3/8 3/4 x 1/2
WEBB# 30291 34574 34820 34818 34819 34821
#46 Flare x Female (FPT) Union MFG# U3-3A U3-4A U3-4B U3-6A U3-6B U3-6C U3-6D U3-6E U3-8B U3-8C U3-8D U3-8E U3-10C U3-10D U3-10E U3-12E
CODE SAE316ODX18FA SAE14ODX18FA SAE14ODXFA SAE38ODX18FA SAE38ODX14FA SAE38ODXFA SAE38ODX12FA SAE38ODX34FA SAE12ODX14FA SAE12ODX38FA SAE12ODXFA SAE12ODX34FA SAE58ODX38FA SAE58ODX12FA SAE58ODX34FA SAE34ODX34FA
SIZE WEBB# 3/16 x 1/819747 1/4 x 1/8 19748 1/4 x 1/4 19749 3/8 x 1/8 19754 3/8 x 1/4 19755 3/8 x 3/8 19756 3/8 x 1/2 19757 3/8 x 3/4 19758 1/2 x 1/4 19759 1/2 x 3/8 19760 1/2 x 1/2 19761 1/2 x 3/4 19762 5/8 x 3/8 19763 5/8 x 1/2 19764 5/8 x 3/4 19765 3/4 x 3/4 19767
#114Swivel Nut MFG# CODE SIZE US4-4 SAE14SWIVELNUT 1/4 US4-6 SAE38SWIVELNUT 3/8 US4-8 SAE12SWIVELNUT 1/2 US4-10 SAE58SWIVELNUT 5/8 US4-86 SAE12X38SWIVELNUT 1/2 x 3/8 US4-108 SAE58X12SWIVELNUT 5/8 x 1/2
WEBB# 78995 77598 77599 78996 95739 95738
MFG# U1-2A U1-3A U1-4A U1-4B U1-4C U1-4D U1-5A U1-5B U1-5C U1-6A U1-6B U1-6C U1-6D U1-6E U1-8B U1-8C U1-8D U1-8E U1-10B U1-10C U1-10D U1-10E U1-12D U1-12E U1-14E
CODE SAE18MUN SAE316X18MUN SAE316X14MUN SAE14X18MUN SAE14MUN SAE14X38MUN SAE14X12MUN SAE516X18MUN SAE516X14MUN SAE516X38MUN SAE38X18MUN SAE38X14MUN SAE38X38MUN SAE38X12MUN SAE38X34MUN SAE12X14MUN SAE12X38MUN SAE12X12MUN SAE12X34MUN SAE58X14MUN SAE58X38MUN SAE58X12MUN SAE58X34MUN SAE34X12MUN SAE34ODX34MUN SAE78X34MUN
SIZE 1/8 x 1/8 3/16 x 1/8 3/16 x 1/4 1/4 x 1/8 1/4 x 1/4 1/4 x 3/8 1/4 x 1/2 5/16 x 1/8 5/16 x 1/4 5/16 x 3/8 3/8 x 1/8 3/8 x 1/4 3/8 x 3/8 3/8 x 1/2 3/8 x 3/4 1/2 x 1/4 1/2 x 3/8 1/2 x 1/2 1/2 x 3/4 5/8 x 1/4 5/8 x 3/8 5/8 x 1/2 5/8 x 3/4 3/4 x 1/2 3/4 x 3/4 7/8 x 3/4
WEBB# 19769 19770 19771 19772 19773 19774 19775 19776 19777 19778 19779 19780 19781 19782 19783 19784 19785 19786 19787 19788 19789 19790 19791 19792 19793 19794
#446 Flare Cap MFG# N5-3 N5-4 N5-5 N5-6 N5-8 N5-10
CODE SAE316CAP SAE14CA SAE516CAP SAE38CA SAE12CA SAE58CAP
SIZE 3/16 1/4 5/16 3/8 1/2 5/8
WEBB# 19735 19736 19737 19738 19739 19740
SIZE 3/16 1/4 5/16 3/8 1/2 5/8
WEBB# 19741 19742 19743 19744 19745 19746
SIZE 1/4 3/8 1/2 5/8
WEBB# 185393 185395 185396 185391
#447 Flare Plug MFG# P2-3 P2-4 P2-5 P2-6 P2-8 P2-10
CODE SAE316PL SAE14PL SAE516PL SAE38PL SAE12PL SAE58PL
#461 Flare Bonnets MFG# B1-4 B1-6 B1-8 B1-10
CODE SAE461-4 SAE38BONNET SAE12BONNET SAE461-10
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
FITTINGS #55 Flare x Flare Elbow
#44 Flare x Flare x Flare Tee MFG# T2-2 T2-3 T2-4 T2-5 T2-6 T2-8 T2-10 T2-12
CODE SAE18T SAE316T SAE14T SAE516T SAE38T SAE12T SAE58T SAE34T
SIZE 1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4
WEBB# 19856 19857 19858 19859 19860 19861 19862 19863
#44R Flare x Flare x Flare Reducing Tee MFG# TR2-446 TR2-664 TR3-668 TR2-886 TR2-10106 TR2-10808 TR2-10810 TR2-868 TR2-8810 TR2-884
CODE SAE14X38T SAE38X14T SAE38X12T SAE12X38T SAE58X38T SAE58X12T SAE58X12X58T SAE12X38X12T SAE12X58T SAE12X14T
SIZE WEBB# 1/4 x 3/8 34825 3/8 x 1/4 34826 3/8 x 1/2 34827 1/2 x 3/8 34833 5/8 x 3/8 34838 5/8 x 1/2 34839 5/8 x 1/2 x 5/8 191825 1/2 x 3/8 x 1/2 192879 1/2 x 5/8 192880 1/2 x 1/4 95513
#45 Flare x Flare x Male (MPT) Tee MFG# T1-3A T1-6C T1-8D T1-5B T1-6B T1-8C T1-10D T1-8B
CODE SAE316ODX18MT2 SAE38ODX38MT2 SAE12ODX12MT2 SAE516ODX14MT5 SAE38ODX14MT5 SAE12ODX38MT5 SAE58ODX12MT5 SAE12X14MT
SIZE 3/16 x 1/8 3/8 x 3/8 1/2 x 1/2 5/16 x 1/4 3/8 x 1/4 1/2 x 3/8 5/8 x 1/2 1/2 x 1/4
WEBB# 19865 19872 19875 19881 19883 19886 19888 85451
SIZE 3/16 1/4 5/16 3/8 1/2 5/8 3/4 3/8 x 1/4 3/8 x 5/16 1/2 x 3/8 5/8 x 3/8 5/8 x 1/2
WEBB# 19722 34570 34813 34571 34572 34814 34815 78997 78998 85455 212746 95512
#481 Forged Flare Nut MFG# NS4-3 NS4-4 NS4-5 NS4-6 NS4-8 NS4-10 NS4-12 NSR4-64 NSR4-65 NSR4-86 NSR4-106 NSR4-108
CODE SAE316NUT SAE14RNUT SAE516RNUT SAE38RNUT SAE12RNUT SAE58RNUT SAE34SRNUT SAE38X14NUT SAE38X516NUT SAE12X38NUT SAE58X38NUT SAE58X12NUT
The VICTOR Propane Equipment Catalog
MFG# E2-2 E2-3 E2-4 E2-5 E2-6 E2-8 E2-10 E2-12 ER2-64 ER2-86 ER2-106 ER2-108
CODE SAE1890 SAE31690 SAE1490 SAE51690 SAE3890 SAE1290 SAE5890 SAE3490 SAE38X1490 SAE12X3890 SAE58X3890 SAE58X1290
SIZE 1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 3/8 x 1/4 1/2 x 3/8 5/8 x 3/8 5/8 x 1/2
WEBB# 19847 19848 19849 19850 19851 19852 19853 19854 34823 34824 94502 94503
#49 Flare x Male (MPT) Elbow MFG# E1-2A E1-3A E1-3B E1-4A E1-4B E1-4C E1-4D E1-5A E1-5B E1-5C E1-6A E1-6B E1-6C E1-6D E1-6E E1-8B E1-8C E1-8D E1-8E E1-10C E1-10D E1-10E E1-12D
CODE SAE18M90 SAE316X18M90 SAE316X14M90 SAE14X18M90 SAE14M90 SAE14X38M90 SAE14ODX12M90 SAE516X18M90 SAE516X14M90 SAE516X38M90 SAE38X18M90 SAE38X14M90 SAE38X38M90 SAE38X12M90 SAE38ODX34M90 SAE12X14M90 SAE12X38M90 SAE12X12M90 SAE12ODX34M90 SAE58X38M90 SAE58ODX12M90 SAE58ODX34M90 SAE34ODX12M90
SIZE 1/8 3/16 x 1/8 3/16 x 1/4 1/4 x 1/8 1/4 1/4 x 3/8 1/4 x 1/2 5/16 x 1/8 5/16 x 1/4 5/16 x 3/8 3/8 x 1/8 3/8 x 1/4 3/8 x 3/8 3/8 x 1/2 3/8 x 3/4 1/2 x 1/4 1/2 x 3/8 1/2 x 1/2 1/2 x 3/4 5/8 x 3/8 5/8 x 1/2 5/8 x 3/4 3/4 x 1/2
WEBB# 19823 19824 19825 19826 19827 19828 19829 19830 19831 19832 19833 19834 19835 19836 19837 19838 19839 19840 19841 19843 19844 19845 19846
#564 Flare x Female (FPT) Elbow MFG# E3-6C E3-6D E3-8D E3-8E E3-10C E3-10D E3-10E
CODE SAE38ODX38F90 SAE38ODX12F90 SAE12ODX12F90 SAE12ODX34F90 SAE58ODX38F90 SAE58ODX12F90 SAE58ODX34F90
SIZE 3/8 x 3/8 3/8 x 1/2 1/2 x 1/2 1/2 x 3/4 5/8 x 3/8 5/8 x 1/2 5/8 x 3/4
WEBB# 19813 19814 19818 19819 19820 19821 19822
FITTINGS
Brass Flare Fittings
107
FITTINGS
108 FITTINGS Propane Hose & Fittings Hose Barb x Inverted Flare
Hose Barb to Male Pipe Fitting PART# SAE14Hx18M SAE14Hx14M SAE14Hx38M SAE38Hx18M SAE38Hx14M SAE38Hx38M SAE38Hx12M
DESCRIPTION 1/4” I.D. Hose x 1/8” MPT 1/4” I.D. Hose x 1/4” MPT 1/4” I.D. Hose x 3/8” MPT 3/8” I.D. Hose x 1/8” MPT 3/8” I.D. Hose x 1/4” MPT 3/8” I.D. Hose x 3/8” MPT 3/8” I.D. Hose x 1/2” MPT
WEBB# 19964 19965 19966 19969 19970 19971 19972
Hose Barb to Female Flare Swivel PART# SAE14Hx38FFL SAE38Hx38FFL SAE38Hx12FFL
DESCRIPTION 1/4” I.D. Hose x 3/8”Female Flare Swivel 3/8” I.D. Hose x 3/8”Female Flare Swivel 3/8” I.D. Hose x 1/2”Female Flare Swivel
WEBB# 110988 184985
Hose Barb to Male Flare PART# DESCRIPTION SAE14Hx38MFL 1/4” I.D. Hose x 3/8” Male Flare SAE38Hx38MFL 3/8” I.D. Hose x 3/8” Male Flare SAE38Hx12MFL 3/8” I.D. Hose x 1/2” Male Flare
WEBB# 193397 182631
Hose Barb to Female Pipe Fitting PART# SAE14Hx18F SAE14Hx14F SAE14Hx38F SAE38Hx18F SAE38Hx14F SAE38Hx38F SAE38Hx12F
DESCRIPTION 1/4” I.D. Hose x 1/8” FPT 1/4” I.D. Hose x 1/4” FPT 1/4” I.D. Hose x 3/8” FPT 3/8” I.D. Hose x 1/8” FPT 3/8” I.D. Hose x 1/4” FPT 3/8” I.D. Hose x 3/8” FPT 3/8” I.D. Hose x 1/2” FPT
WEBB# 184998 19941 19942 185000 19946 19947 19948
WEBB# 182653
Dayco LP Grill Hose PART# HOS14-2 HOS516 HOS3/8 HOS1/2 HOS3/4
DESCRIPTION
WEBB# 185588 5/16” Double Braid Hose 221996 3/8” Double Braid Hose 185605 1/2” Double Braid Hose 185581 3/4” Double Braid Hose 185604 1/4” Double Braid Hose
Brass Hose Ferrule PART# HOF7326 HOF7327 HOF7328 HOF7329 HOF7331 HOF7333 SPFKT-15
SIZE .593” .625” .656” .687” .750” .812”
DESCRIPTION Brass Hose Ferrule for 1/4” Single Braid Brass Hose Ferrule for 1/4” Double Braid Brass Hose Ferrule for 1/4” Double Braid Brass Hose Ferrule for 3/8” Single Braid Brass Hose Ferrule for 3/8” Double Braid Brass Hose Ferrule for 3/8” Double Braid 3-Hole Crimping Tool for Brass Ferrule
WEBB# 185561 185562 185563 185564 185565 185566 184210
Ear Clamps & Jaw Pinchers PART# OET0911 HOF1098 OET1113 OET1315 OET1517 OET1518 OET1720 OET2225 OET2327
DESCRIPTION WEBB# Oetiker 2 Ear Clamp 7/16” 183382 Standard Jaw Pinchers 185559 Oetiker 2 Ear Clamp 1/2” 183383 Oetiker 2 Ear Clamp 9/16” (1/4” Single Braid Hose) 183384 Oetiker 2 Ear Clamp 19/32” (1/4” Double Braid Hose) 183385 Oetiker 2 Ear Clamp 5/8” (1/4” Double Braid Hose) 183386 Oetiker 2 Ear Clamp 3/4” (3/8” Double Braid Hose) 183388 Oetiker 2 Ear Clamp 15/16” 183387 Oetiker 2 Ear Clamp 1” 188115
Hansen Gas-Mate Coupling
Hose Barb to 9/16”—18 LH Female Swivel PART# DESCRIPTION WEBB# SAE14Hx916FL 1/4” Hose Nip x 9/16”–18 LH Female Swivel 193399 SAE38Hx916FL 3/8” Hose Nip x 9/16”–18 LH Female Swivel 193398
Hose Barb x Soft Nose Hand Wheel POL PART# DESCRIPTION WEBB# SAE14HxMPOLHW 1/4” I.D. Hose x Soft Nose Hand Wheel POL 182646
Hose Barb x POL PART# DESCRIPTION SAE14HxMPOL 1/4” I.D. Hose x POL (7/8” Hex)
PART# DESCRIPTION MAB5133 1/4” I.D. Hose x 1/4” Inverted Flare Male
WEBB# 182655
One-way shut-off Safety Couplings are designed for LP and natural gas applications where 3/8”, 1/2”, 3/4”, 1”, and 11/4” hose is used.
PART# 100-006
FEMALE END CONNEC. 3/8” FPT, Socket Only
DIMENSIONS WEBB# 2.44 x 1.13 x 1.00 202616
100-008
1/2” FPT, Socket Only
2.84 x 1.38 x 1.13 182153
100-010
3/4” FPT, Socket Only
3.17 x 1.75 x 1.50 182146
100-012
1” FPT, Socket Only
3.94 x 2.13 x 1.75
100-506
3/8” FPT,Plug Only
1.59 x 0.94 x 0.81 182158
100-508
1/2” FPT, Plug Only
1.94 x 1.16 x 1.00 182154
100-510
3/4” FPT, Plug Only
2.06 x 1.52 x 1.31 182147
100-512
1” FPT, Plug Only
2.47 x 1.73 x 1.50
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
FITTINGS MFR# DESCRIPTION Tank Unions – with O-Ring Seal
Multiple Appliance Hookups
WEBB#
MFR# DESCRIPTION Distribution Posts and Adapter 4174 10” Post 4184 30” Post 4184H 30” Post w/Hose (#4120)
4132 with E-Z Hand Wheel POL 3132 Wrench Tighten
180748
90° Tank Unions – with Shut-off and O-ring Seal
180775 180776
3142 Post Adapter Connects hose #3120 or #3121180756 to distribution post or disposable cylinder.
4137 with E-Z Hand Wheel POL
180774
3137 Wrench Tighten
180752
Tank Union Component Parts 3139 Soft Seal POL Nut
180753
3140 Plain Adapter
180754
E-Z Multi-Accessory Hose 4120 5’ Hose 4121 12’ Hose
4192 E-Z “Add-on” Adapter Connects 2 180778 appliances which use disposable cylinders to distribution post.
180742 180743
Hose Assembly Component Parts 3120 5’ Hoses – Wrench Tighten 3121 12’ Hose – Wrench Tighten
180740 180741
3129 Soft Seal POL
180746
180771 180772
Splitters—Each DC-M outlet has an automatic shut-off 4191 E-Z “Two-in-one” DC Adapter Connects 2 180777 appliances which use disposable cylinders to bulk tank.
Hose Assemblies with Fittings 4122 5’ E-Z Hose with Hand Wheel 180723 4123 12’ E-Z Hose with Hand Wheel 180773 3122 5’ Hose Wrench Tighten 3123 12’ Hose Wrench Tighten
WEBB#
9/16 F
9/16 F
4193 E-Z “Two-in-one” POL Adapter w/Pol Plug Connects 2 appliances to bulk tank.
180779
4194 E-Z “Combo Adapter” includes Pol Plug
180781
3130 Adapter w/shutoff & o-ring seal 180747 Easy-to-Use Conversion Kit 3101 Converts 2 or 3 burner Coleman 180731 Gasoline Stove to propane,no tool required
3141 Disposable cylinder male adapter
180755
3143 Post Adapter
180757
3144 POL Female Adapter
180758
3139 Soft Seal POL Nut
180753
3169 POL Plastic Plug
184408
▲
▲
Coleman or Primus Campstove hookup using a tank union. (Inset) Single high pressure appliance hookup using a hose assembly.
Splitters—Component Parts—Configure your own 3134 “Y” Block 180750
▲
Single high pressure appliance hookup using a 90° tank union.
The VICTOR Propane Equipment Catalog
Alternate multiple high pressure appliance hookup using an E-Z adapter.
▲
▲ 2 or 3 burner Coleman Gasoline Stove converted to propane using Easy-ToUse Conversion Kit
Multiple High Pressure appliance hookup using E-Z distribution post.
FITTINGS
Single High Pressure Appliance Hookups
109
Low Pressure Appliance Hookups
Kamco Gas Outlet Box
Model #G0101-5
MFR# DESCRIPTION WEBB# Hose Assemblies (including regulator) 4117 5’ Hose 180770 4118 12’ Hose 178908
Completely enclosed in a UV and fire protectant PVC box, manufactured to ISO 9220 standard, the gas outlet is an ideal means of safely and securely connecting your gas barbecue, patio heater, stove or dryer directly to your residential gas supply. • Eliminates refilling tanks, gas identification • Quick disconnect safety shutoff with easy access • C/W standoffs for siding installation • CGA & AGA approved for Indoor/Outdoor use • Approved for temperatures to -40° • Inlet connection — 3/8” N.P.T. • Hose connection — 3/8” Quick Disconnect
Component Parts 3136 Replacement 11” Low Pressure 180751 Regulator (includes POL #3139) 3124 Hose – Wrench Tighten – 5’ 3125 Hose – Wrench Tighten – 12’
180744 180745
Replacement Gas Grill Hoses 3103 24’ Hose 3105 36” Hose
180732 180734
“Cookout Saver” Reserve Gas Adapter 3160 178911 Replacement Flexible Hose Pigtails 3112 12” Hose – 12” POLM x 1/4 IMF 3113 18” Hose – 18” POLM x 1/4 IMF 3114 24” Hose – 24” POLM x 1/4 IMF 3115 30” Hose – 30” POLM x 1/4 IMF 3116 36” Hose – 36” POLM x 1/4 IMF
180735 180736 180737 180738 180739
Commonly Used Quick Disconnectors 3162 Between POL & Regulator
180764
3163 With Gas Grill Hoses
180765
3164 With High Pressure Appliances
180766
1/4 MP 3/8 MP
9/16 M
Reducing and Connecting Adapters 3152 1/4 MPT x 9/16 M 180759 180760 3153 3/8 MPT x 9/16 M 180761 3154 9/16 M x 9/16 M 3159 1/4 MPT x 9/16 F 180762
▲
FITTINGS
110 FITTINGS
▲
Low pressure gas grill hookup to bulk tank. (inset) “Cookout Saver” reserve gas adapter can be used to connect gas grill to disposable cylinder if bulk tank runs dry.
Add a high pressure appliance hookup to a camper/trailer’s existing outside tank.
MFR# G0101-5W
SIZE 6” x 41/2” x 21/2”
BTUS 60,000
COLOR White
WEBB# 191025
1/4 FP 3/8 FP
9/16 F
Humphrey Gaslights MFR# DESCRIPTION WEBB# Premium Colors HUM9CC Classic Chrome 185634 HUM9HPB Brass 185635 Standard Colors HUM9GR Hunter Green 190593 HUM9NA Natural Almond 165849 HUM9PG Pebble Gray 178685 HUM9RW Rustic Walnut 178683 RV Lights HUM9TNA Natural Almond 190595 HUM9TPG Pebble Gray 185636 HUM9TRW Rustic Walnut 185637 Globes HUML6-20A Pyrex, Half Frosted 178902 HUML6-27A Fawn 185640 HUML6-28A Mallard 185641 Parts HUML10-71A Bunsen 178906 HUML12-11A RV Burner Nose 178905 HUML12-2A Burner Nose 178904 HUML9-51A Nat gas Burner Nose 188913 HUML13-2 Mantle 165850 HUML13-6-5PK Tie-on Mantle, 5 PK 178912 HUML24-15-6PK Asbestos Seal, 6 PK 185639 HUML8-6C Wall Plate Assembly 178903 HUML9-50A LP Gas Nozzle f/9-9T 178907 HUML9-52A High Altitude Orifice 185642 Multiple Light Manifold HUMOPK Ceiling Mounting Kit 178901
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
FITTINGS
111
45° Elbow MFR# MAL1845 MAL1445 MAL3845 MAL1245 MAL3445 MAL145 MAL11445 MAL11245 MAL245 MAL21245 MAL345
WEBB# 12559 12560 12561 12562 12563 12564 12565 12566 12567 12568 12569
MFR# MAL1845 MAL14CR MAL38CR MAL12CR MAL34CR MAL1CR MAL114CR MAL112CR MAL2CR
SIZE 1/8” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
WEBB# 12759 12760 12761 12762 12763 12764 12765 12766 12767
45° Street Elbow MFR# MAL18S45 MAL14S45 MAL38S45 MAL12S45 MAL34S45 MAL1S45 MAL114S45 MAL112S45 MAL2S45
SIZE 1/8” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
WEBB# 12574 12575 12576 12577 12578 12579 12580 12581 12582
90° Elbow MFR# MAL1890 MAL1490 MAL3890 MAL1290 MAL3490 MAL190 MAL11490 MAL11290 MAL290 MAL21290 MAL390
SIZE 1/8” 1/4” 3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3”
WEBB# 12503 12504 12505 12506 12507 12508 12509 12510 12511 12512 12513
90° Street Elbow MFR# MAL18S90 MAL14S90 MAL38S90 MAL12S90 MAL34S90 MAL1S90 MAL114S90 MAL112S90 MAL2S90 MAL212S90
SIZE 1/8” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2”
WEBB# 12547 12548 12549 12550 12551 12552 12553 12554 12555 12556
Coupling MFR# MAL18CO MAL14CO MAL38CO MAL12CO MAL34CO MAL1CO MAL114CO MAL112CO MAL2CO MAL3CO
SIZE 1/8” 1/4” 3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 3”
WEBB# 12774 12775 12776 12777 12778 12779 12780 12781 12782 12784
90° Reducing Elbow MFR# SIZE MAL14X1890 1/4” x 1/8” MAL38X1490 3/8” x 1/4” MAL12X3890 1/2” x 3/8” MAL12X1490 1/2” x 1/4” MAL34X1290 3/4” x 1/2” MAL34X3890 3/4” x 3/8” MAL34X1490 3/4” x 1/4” MAL1X3490 1” x 3/4” MAL1X1290 1” x 1/2” MAL114X190 11/4” x 1” MAL114X3490 11/4” x 3/4” MAL114X1290 11/4” x 1/2” MAL112X11490 11/2” x 11/4” MAL112X190 11/2” x 1” MAL112X3490 11/2” x 3/4” MAL2X11290 2” x 11/2” MAL2X11490 2” x 11/4” MAL2X190 2” x 1” MAL2X3490 2” x 3/4” MAL212X290 21/2” x 2” MAL212X11290 21/2” x 11/2” MAL3X21290 3” x 21/2” MAL3X290 3” x 2”
The VICTOR Propane Equipment Catalog
Bushing
Plug
Cross SIZE 1/8” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3”
WEBB# 12518 12519 12521 12522 12523 12524 12525 12526 12527 12529 12530 12531 12532 12533 12534 12535 12536 12537 12538 12539 12540 12541 12542
MFR# Solid BCI18SOPL BCI14SOPL BCI38SOPL BCI12SOPL BCI34SOPL BCI1SOPL BCISO2PL Cored BCI12PL BCI34PL BCI1PL BCI114PL BCI112PL BCI2PL BCI212PL BCI3PL
SIZE 1/8” 1/4” 3/8” 1/2” 3/4”
1” 2” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3”
WEBB# 1380 1381 1382 1383 1371 197665 1388 206693 203284 1385 1373 1387 1375 1376 1377
Cap MFR# MAL18CA MAL14CA MAL38CA MAL12CA MAL34CA MAL1CA MAL114CA MAL112CA MAL2CA MAL212CA MAL3CA
SIZE 1/8” 1/4” 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3”
WEBB# 12851 12852 12853 12854 12855 12856 12857 12858 12859 12860 12861
MFR# BCI14X18BU BCI38X14BU BCI38X18BU BCI12X38BU BCI12X14BU BCI12X18BU BCI34X12BU BCI34X38BU BCI34X14BU BCI34X18BU BCI1X34BU BCI1X12BU BCI1X38BU BCI1X14BU BCI1X18BU BCI114X1BU BCI114X34BU BCI114X12BU BCI114X38BU BCI114X14BU BCI114X18BU BCI112X114BU BCI112X1BU BCI112X34BU BCI112X12BU BCI2X112BU BCI2X114BU BCI2X1BU BCI2X34BU BCI2X12BU BCI212X2BU BCI212X112BU BCI212X114BU BCI212X1BU BCI3X212BU BCI3X2BU BCI3X1BU
SIZE
WEBB# 1257 1258 1259 1/2” x 3/8” 1260 1/2” x 1/4” 1261 1/2” x 1/8” 1262 3/4” x 1/2” 1263 3/4” x 3/8” 1264 3/4” x 1/4” 1265 3/4” x 1/8” 1266 1” x 3/4” 1267 1” x 1/2” 1268 1” x 3/8” 1269 1” x 1/4” 1270 1” x 1/8” 1271 11/4” x 1” 1272 11/4” x 3/4” 1273 11/4” x 1/2” 1274 11/4” x 3/8” 1275 11/4” x 1/4” 1276 11/4” x 1/8” 76976 11/2” x 11/4”1277 11/2” x 1” 1278 11/2” x 3/4” 1279 11/2” x 1/2” 1280 2” x 11/2” 1283 2” x 11/4” 1284 2” x 1” 1285 2” x 3/4” 1286 2” x 1/2” 1287 21/2” x 2” 1290 21/2” x 11/2” 1291 21/2” x 11/4”1292 21/2” x 1” 1293 3” x 21/2” 1296 3” x 2” 1297 3” x 1” 1300 1/4” x 1/8” 3/8” x 1/4” 3/8” x 1/8”
Union MFR# MAL18UN MAL14UN MAL38UN MAL12UN MAL34UN MAL1UN MAL114UN MAL112UN MAL2UN MAL3UN
SIZE 1/8” 1/4” 3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 3”
WEBB# 54291 30254 30255 30256 30257 30258 30259 30260 30262 30263
Tee MFR# MAL18T MAL14T
SIZE 1/8” 1/4”
WEBB# 12586 12587
MAL38T MAL12T
3/8”
12588 12589
1/2”
MAL34T MAL1T
1”
3/4”
12590 12591
MAL114T MAL112T
11/4” 11/2”
12592 12593
MAL2T MAL212T
2” 21/2”
12594 12595
MAL3T
3”
12596
FITTINGS
Black Malleable Fittings
FITTINGS
112 FITTINGS Black Malleable Fittings (Cont.) Reducing Tee MFR# MAL18X18X14T MAL14X14X18T MAL38X38X14T MAL38X14X14T MAL12X12X1T MAL12X12X34T MAL12X12X38T MAL12X38X12T MAL12X38X38T MAL12X14X12T MAL34X12X12T MAL34X12X34T MAL34X14X34T MAL34X34X114T MAL34X34X12T MAL34X34X14T MAL34X34X1T MAL34X34X38T MAL1X1X12T MAL1X1X112T MA1X1X114T MAL1X1X38T MAL1X1X12T MAL1X34X1T MAL1X34X34T MAL1X34X12T MAL1X12X1T MAL1X12X34T MAL1X12X12T MAL1X14X1T MAL114X114X2T MAL114X114X112T MAL114X114X1T MAL114X114X34T MAL114X114X12T MAL114X1X112T MAL114X1X114T MAL114X1X1T MAL114X1X34T MAL114X1X12T MAL114X34X114T MAL114X34X1T MAL114X34X34T MAL114X12X114T MAL114X12X1T MAL112X112X2T MAL112X112X114T MAL112X112X1T MAL112X112X34T MAL112x112x12T
Reducing Tee (Cont.) SIZE WEBB# 1/8” x 1/8” x 1/4” 12601 1/4” x 1/4” x 1/8” 12603 3/8” x 3/8” x 1/4” 12605 3/8”x 1/4”x 1/4” 12608 1/2” x 1/2” x 1” 12609 1/2” x 1/2” x 3/4” 12610 1/2” x 1/2” x 3/8” 12611 1/2” x 3/8” x 1/2” 12613 1/2” x 3/8” x 3/8” 12614 1/2” x 1/4” x 1/2” 12615 3/4” x 1/2” x 1/2” 12622 3/4” x 1/2” x 3/4” 12621 3/4” x 1/4” x 3/4” 12625 3/4” x 3/4” x 11/4” 12616 3/4” x 3/4” x 1/2” 12618 3/4” x 3/4” x 1/4” 12620 3/4” x 3/4” x 1” 12617 3/4” x 3/4” x 3/8” 12619 1” x 1” x 1/2” 12626 1” x 1” x 11/2” 12627 1” x 1” x 11/4” 12628 1” x 1” x 3/8” 12631 1” x 1” x 1/2” 12632 1” x 3/4” x 1” 12633 1” x 3/4” x 3/4” 12634 1” x 3/4” x 1/2” 12635 1” x 1/2” x 1” 12636 1” x 1/2” x 3/4” 12637 1” x 1/2” x 1/2” 12638 1” x 1/4” x 1” 12639 11/4” x 11/4” x 2” 12640 11/4” x 11/4” x 11/2” 12641 11/4” x 11/4” x 1” 12642 11/4” x 11/4” x 3/4” 12643 11/4” x 11/4” x 1/2” 12644 11/4” x 1” x 11/2” 12646 11/4” x 1” x 11/4” 12647 11/4” x 1” x 1” 12648 11/4” x 1” x 3/4” 12649 11/4” x 1” x 1/2” 12650 11/4” x 3/4” x 11/4” 12651 11/4” x 3/4” x 1” 12652 11/4” x 3/4” x 3/4” 12653 11/4” x 1/2” x 11/4” 12655 11/4” x 1/2” x 1” 12656 11/2” x 11/2” x 2” 12661 11/2” x 11/2” x 11/4” 12662 11/2” x 11/2” x 1” 12663 11/2” x 11/2” x 3/4” 12664 11/2” x 11/2” x 1/2” 12665
MFR# MAL112X114X112T MAL112X114X114T MAL112X114X1T MAL112X114X34T MAL112X114X12T MAL112X1X112T MAL112X1X114T MAL112X1X1T MAL112X1X34T MAL112X34X112T MAL34X12X34T MAL112X34X1T MAL112X12X112T MAL2X2X212T MAL2X2X112T MAL2X2X114T MAL2X2X1T MAL2X2X34T MAL2X2X12T MAL2X112X2T MAL2X112X112T MAL2X112X114T MAL2X112X1T MAL2X112X34T MAL2X114X2T MAL2X114X114T MAL2X1X2T MAL2X1X1T MAL2X34X2T MAL1X12X2T MAL212X212X3T MAL212X212X2T MAL212X212X112T MAL212X212X114T MAL212X212X1T MAL212X212X34T MAL212X2X212T MAL212X2X2T MAL212X112X212T MAL212X112X2T MAL3X3X212T MAL3X3X2T MAL3X3X112T MAL3X3X114T MAL3X3X1T MAL3X3X34T MAL3X212X212T MAL3X212X2T MAL3X2X3T MAL3X2X2T
SIZE WEBB# 11/2” x 11/4” x 11/2” 12667 11/2” x 11/4” x 11/4” 12668 11/2” x 11/4” x 1” 12669 11/2” x 11/4” x 3/4” 12670 11/2” x 11/4” x 1/2” 12671 11/2” x 1” x 11/2” 12672 11/2” x 1” x 11/4” 12673 11/2” x 1” x 1” 12674 11/2” x 1” x 3/4” 12675 11/2” x 3/4” x 11/2” 12677 11/2” x 3/4” x 1” 12679 11/2” x 3/4” x 3/4” 12680 11/2” x 1/2” x 11/2” 12681 2” x 2” x 21/2” 12684 2” x 2” x 11/2” 12685 2” x 2” x 11/4” 12686 2” x 2” x 1” 12687 2” x 2” x 3/4” 12688 2” x 2” x 1/2” 12689 2” x 11/2” x 2” 12690 2” x 11/2” x 11/2” 12691 2” x 11/2” x 11/4” 12692 2” x 11/2” x 1” 12693 2” x 11/2” x 3/4” 12694 2” x 11/4” x 2” 12695 2” x 11/4” x 11/4” 12697 2” x 1” x 2” 12699 2” x 1” x 1” 12702 2” x 3/4” x 2” 12704 1” x 1/2” x 2” 12706 21/2” x 21/2” x 3” 12707 21/2” x 21/2” x 2” 12708 21/2” x 21/2” x 11/2” 12709 21/2” x 21/2” x 11/4” 12710 21/2” x 21/2” x 1” 12711 21/2” x 21/2” x 3/4” 12712 21/2” x 2” x 21/2” 12713 21/2” x 2” x 2” 12714 21/2” x 11/2” x 21/2” 12716 21/2” x 11/2” x 2” 12717 3” x 3” x 21/2” 12719 3” x 3” x 2” 12720 3” x 3” x 11/2” 12721 3” x 3” x 11/4” 12722 3” x 3” x 1” 12723 3” x 3” x 3/4” 12724 3” x 21/2” x 21/2” 12726 3” x 21/2” x 2” 12727 3” x 2” x 3” 12729 3” x 2” x 2” 12730
Reducing Coupling MFR# BCI14X18CO BCI38X14CO BCI38X18CO BCI12X38CO BCI12X14CO BCI12X18CO BCI34X12CO BCI34X38CO BCI34X14CO BCI34X18CO BCI1X34CO BCI1X12CO BCI1X38CO BCI1X14CO BCI114X1CO BCI114X34CO BCI114X12CO BCI114X38CO BCI114X14CO BCI112X114CO BCI112X1CO BCI112X34CO BCI112X12CO BCI2X112CO BCI2X114CO BCI2X1CO BCI2X34CO BCI2X12CO BCI212X2CO BCI212X112CO BCI212X114CO BCI212X1CO BCI3X212CO BCI3X2CO BCI3X112CO BCI3X114CO BCI3X1CO
SIZE 1/4” x 1/8” 3/8” x 1/4” 3/8” x 1/8” 1/2” x 3/8” 1/2” x 1/4” 1/2” x 1/8” 3/4” x 1/2” 3/4” x 3/8” 3/4” x 1/4” 3/4” x 1/8” 1” x 3/4” 1” x 1/2” 1” x 3/8” 1” x 1/4” 11/4” x 1” 11/4” x 3/4” 11/4” x 1/2” 11/4” x 3/8” 11/4” x 1/4” 11/2” x 11/4” 11/2” x 1” 11/2” x 3/4” 11/2” x 1/2” 2” x 11/2” 2” x 11/4” 2” x 1” 2” x 3/4” 2” x 1/2” 21/2” x 2” 21/2” x 11/2” 21/2” x 11/4” 21/2” x 1” 3” x 21/2” 3” x 2” 3” x 11/2” 3” x 11/4” 3” x 1”
WEBB# 12789 12790 12791 12792 12793 12794 12795 12796 12797 12798 12799 12800 12801 12802 12803 12804 12805 12806 12808 12808 12809 12810 12811 12813 12814 12815 12816 12817 12818 12819 12820 12821 12822 12823 12824 12825 12826
Floor Flanges MFR# MAL12FLFLG MAL34FLFLG MAL1FLFLG MAL114FLFLG MAL112FLFLG MAL2FLFLG
SIZE 1/2” 3/4”
1” 11/4” 11/2” 2”
WEBB# 12879 12880 12881 12882 12883 12884
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
FITTINGS
113
PART# SIZE CLOSE 1 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6
WEBB# 1/8”
PART#
WEBB#
NIP14XCLO 14132
NIP18X1
NIP14X1
WEBB# 1/2”
NIP12XCLO 14154 NIP12X1
WEBB# PART# 3/4”
WEBB# 1”
NIP34XCLO 14171
NIP1XCLO
14188
184981
NIP38X112 14144
NIP12X112 14155
NIP34X112
14172
NIP114X112 90247
NIP18X2
NIP14X2
NIP38X2
NIP12X2
NIP34X2
14173
NIP1X2
14189
NIP18X212 14124
14123
NIP14X212 14135
NIP38X212 14146
NIP12X212 14157
NIP34X212
14174
NIP1X212
14190
NIP18X3
NIP14X3
NIP38X3
NIP12X3
14125
14134
NIP34X3
14175
NIP1X3
14191
NIP14X312 14137
NIP38X312 14148
NIP12X312 14159
NIP34X312
14176
NIP1X312
14192
NIP18X4
NIP14X4
NIP38X4
NIP12X4
NIP34X4
14177
NIP1X4
14193
14138
14147
14156
NIP18X312 14126 14127
14136
14145
14149
14158 14160
NIP18X412 14128
NIP14X412 14139
NIP38X412 14150
NIP12X412 14161
NIP34X412
14178
NIP1X412
14194
NIP18X5
NIP14X5
NIP38X5
NIP12X5
NIP34X5
14179
NIP1X5
14195
14129
14140
14151
14162
NIP18X512 14130
NIP14X512 14141
NIP38X512 14152
NIP12X512 14163
NIP34X512
14180
NIP1X512
14196
NIP18X6
NIP14X6
NIP38X6
NIP12X6
NIP1X6
14197
NIP1X7
14198
NIP1X712
225068
14131
14142
NIP18X7
110506
NIP14X7
93181
NIP18X8
89010
NIP14X8
90181
NIP18X9
153003
NIP14X9
86243
NIP34X6
14181
NIP38X612 153667
14153
NIP12X612 90214
NIP34X612
86309
NIP38X7
NIP12X7
NIP34X7
14182
67730
14164 14165
NIP38X712 213295
NIP12X712 225065
NIP38X8
NIP12X8
110509
14166
NIP38X812 90197
NIP12X812 90217
NIP38X9
NIP12X9
213167
14167
9 1/2 10
PART#
NIP14X112 14133
81/2 9
PART#
NIP18X112 14122
71/2 8
NIP38XCLO 14143
90178
61/2 7
WEBB# 3/8”
NIP18XCLO 14121 89013
PART#
1/4”
NIP18X10
153238
NIP14X10
90179
NIP38X10
79993
NIP12X10
14168
101/2
14183
NIP1X8
14199
NIP1X812
210728
NIP34X9
14184
NIP1X9
14200
NIP34X912
209203 NIP1X912
243409
NIP34X10
14185
14201
NIP1X10
NIP34X1012 225069 NIP1X1012
225066
11
NIP14X11
206628
NIP38X11
NIP12X11
14169
NIP34X11
14186
NIP1X11
14202
12
NIP14X12
90180
NIP38X12I 153004
NIP12X12
14170
NIP34X12
14187
NIP1X12
14203
NIP38X13
NIP12X13
91833
NIP34X13
209208 NIP1X13
218014
NIP12X14
85163
NIP34X14
92234
NIP1X14
86475
NIP34X15
83865
NIP1X15
83866
NIP1X16
95382
13 14
NIP14X14
90199
NIP34X8
225073
85164
15 16
NIP38X16
242818
NIP12X16
250310
17 171/2 18
NIP14X18
14776
NIP38X18
14784
NIP12X18
14792
NIP34X18
14800
NIP34X20
90233
NIP1X17
247341
NIP1X1712
225067
NIP1X18
14808
NIP1X22
198537
NIP1X24
14809
19 20 21 22 24
NIP14X24
14777
NIP38X24
14785
NIP12X24
14793
NIP34X24
14801
NIP34X28
250047
26 27 28 30
NIP14X30
14778
NIP12X30
14794
NIP34X30
14802
NIP1X30
14810
36
NIP14X36
14779
NIP12X36
14795
NIP34X36
14803
NIP1X36
14811
40
NIP34X40
250050 NIP1X40
250046
42
NIP34X42
14804
NIP1X42
14812
NIP34X48
14805
NIP1X48
14813
NIP1X53
210727
43 48
NIP14X48
14781
NIP12X48
14797
53 54 60
The VICTOR Propane Equipment Catalog
NIP12X60
14799
NIP34X54
14806
NIP1X54
14814
NIP34X60
14807
NIP1X60
14815
FITTINGS
Schedule 40 Nipples 1 / 8 ” — 1”
FITTINGS
114 FITTINGS Schedule 40 Nipples (cont.)
11 / 4 ” — 3”
PART# SIZE
WEBB# PART# 11/4”
WEBB# PART# 11/2”
CLOSE NIP114XCLO 14204
WEBB# PART# 2”
NIP112XCLO 14219
WEBB# PART# 21/2”
NIP2XCLO
14235
WEBB# 3”
NIP212XCLO
14250
NIP3XCLO
14264
1 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6
NIP114X112 90247 NIP114X2
14205
NIP112X2
14220
NIP114X212 14206
NIP112X212 14221
NIP2X212
14236
NIP114X3
NIP112X3
NIP2X3
14237
NIP212X3
14251
NIP3X3
14265
NIP114X312 14208
14207
NIP112X312 14223
NIP2X312
14238
NIP212X312
14252
NIP3X312
14266
NIP114X4
NIP112X4
NIP2X4
14239
NIP212X4
14253
NIP3X4
14267
14209
14222 14224
NIP114X412 14210
NIP112X412 14225
NIP2X412
14240
NIP212X412
14254
NIP3X412
14268
NIP114X5
NIP112X5
NIP2X5
14241
NIP212X5
14255
NIP3X5
14269
14211
14226
NIP114X512 14212
NIP112X512 14227
NIP2X512
14242
NIP212X512
14256
NIP3X512
14270
NIP114X6
NIP112X6
NIP2X6
14243
NIP212X6
14257
NIP3X6
14271
NIP2X612
213045
NIP3X612
79300
NIP2X7
14244
NIP3X7
14272
NIP3X712
79301
14213
14228
61/2 7
NIP114X7
14214
71/2 8
14229
NIP212X7
14258
NIP112X712 225057 NIP114X8
14215
NIP114X9
14216
NIP112X9
NIP114X10
30269
NIP112X10
81/2 9
NIP112X7 NIP112X8
14230
NIP2X8
14245
NIP212X8
14259
NIP3X8
14273
14231
NIP2X9
14246
NIP212X9
14260
NIP3X9
14274
NIP3X912
86318
14232
NIP2X10
14247
NIP212X10
14261
NIP3X10
14275
NIP112X812 225072
91/2 10 101/2
NIP3X1012 86307
11
NIP114X11
14217
NIP112X11
14233
NIP2X11
14248
NIP212X11
14262
NIP3X11
14276
12
NIP114X12
14218
NIP112X12
14234
NIP2X12
14249
NIP212X12
14263
NIP3X12
14277
13
NIP114X13
210739
14
NIP114X14
86474
NIP112X14
79994
NIP212X14
67731
NIP3X14
67735
15
NIP114X15
83867 NIP112X16
210719 NIP2X16
91158
NIP212X16
67732
NIP3X16
75575
NIP112X18
14824
14832
NIP212X18
67733
NIP3X18
67324
20
NIP112X20
190334
NIP212X20
67734
NIP3X20
67736
21
NIP112X21
90251
NIP212X22
75574
NIP3X22
67737
NIP212X24
86476
NIP3X24
67325
NIP212X30
200226 NIP3X30
67326
NIP3X36
67327
16 17 171/2 18
NIP114X18
14816
19
NIP114X19
190331
NIP2X18
NIP2X21
90307
22 24
NIP114X24
14817
26
NIP114X26
215917
NIP112X24
14825
27
NIP2X24
14833
NIP2X27
210730
28 30
NIP114X30
14818
NIP112X30
14826
NIP2X30
14834
36
NIP114X36
14819
NIP112X36
14827
NIP2X36
14835
NIP2X40
210732
NIP114X42
14820
NIP112X42
14828
NIP2X42
14836
NIP112X43
216472
NIP114X48
14821
NIP112X48
14829
NIP2X48
14837
54
NIP114X54
14822
NIP112X54
14830
NIP2X54
14838
60
NIP114X60
14823
NIP2X60
14839
40 42 43 48 53
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
FITTINGS
115
45° Elbow
FITTINGS
Forged Steel Fittings, 3000# Socket Weld
Tee SIZE
Reducer Coupling
MFR# F/S12453SW
WEBB# 8933
MFR#
SIZE
WEBB#
WEBB#
MFR#
SIZE
1/2”
F/S12T3SW
1/2”
8945
F/S12X14R3SW
1/2” x 1/4”
34914
F/S34453SW
3/4”
8934
F/S34T3SW
3/4”
8946
F/S12X38R3SW
1/2” x 3/8”
34915
F/S1453SW
1”
8935
F/S1X12T3SW
1” x 1” x 1/2”
86648
F/S34X14CO3SW 3/4” x 1/4”
8986
F/S114453SW
11/4”
8936
F/S114T3SW
11/4”
8948
F/S34X38R3SW
3/4” x 3/8”
34928
F/S112453SW
11/2”
8937
F/S112T3SW
11/2”
8949
F/S34X12R3SW
3/4” x 1/2”
34927
F/S2453SW
2”
8938
F/S2T3SW
2”
8950
F/S1X14CO3SW
1” x 1/4”
8991
F/S212453SW
21/2”
8939
F/S212T3SW
21/2”
8951
F/S1X38CO3SW
1” x 3/8”
8990
F/S3453SW
3”
8940
F/S3T3SW
3”
8952
F/S1X12R3SW
1” x 1/2”
34918
F/S34X12T3SW
3/4” x 3/4” x 1/2”
177016
F/S1X34R3SW
1” x 3/4”
F/S112X1T3SW
11/2” x 11/2” x 1”
77863
F/S114X12R3SW 11/4” x 1/2”
34910 34912
34919
F/S2X1T3SW
2” x 2” x 1”
77864
F/S114X34R3SW 11/4” x 3/4”
90° Elbow
F/S2X112T3SW
2” x 11/2”
90134
F/S114X1R3SW
MFR# F/S12903SW
SIZE 1/2”
WEBB# 8921
F/S1T3SW
1”
8947
F/S112X12R3SW 11/2” x 1/2”
34905
F/S114X343SW
11/4”
200474
F/S112X34R3SW 11/2” x 3/4”
34908
F/S34903SW
3/4”
8922
F/S112X34T3SW
11/2” x 11/2” x 3/4” 77862
F/S112X1R3SW
34906
8923
F/S2X112T3SW
2” x 2” x 11/2”
F/S112X114R3SW 11/2” x 11/4”
34903
Insert
F/S1X112R3SW
2” x 11/2”
34921
F/S2X114R3SW
2” x 11/4”
34922
F/S2X1R3SW
2” x 1”
9006
9050
F/S2X34R3SW
2” x 3/4”
9007
9054
F/S2X12R3SW
2” x 1/2”
9008
F/S212X2R3SW
21/2” x 2”
81774
F/S1903SW F/S114903SW
1” 11/4”
8924
90134
F/S112903SW
11/2”
8925
MFR#
SIZE
WEBB#
F/S2903SW
2”
8926
F/S12X14I3SW
1/2” x 1/4”
30641
F/S212903SW F/S3903SW
21/2” 3”
8927 8928
F/S12X38ISW F/S34X14I3SW
3/4” x 1/4”
34911
11/2” x 1”
F/S34X38I3SW
3/4” x 3/8”
9053
F/S34X12I3SW
3/4” x 1/2”
9052
F/S212X112R3SW 21/2” x 11/2”
202425
9058
F/S212X114CO3SW 21/2” x 11/4”
200481
F/S3X112R3SW
3” x 11/2”
81778
F/S1X38I3SW
Cap
1/2” x 3/8”
11/4” x 1”
1” x 3/8”
F/S1X12I3SW
1” x 1/2”
9057
MFR#
SIZE
WEBB#
F/S1X34I3SW
1” x 3/4”
9056
F/S12CA3SW
1/2”
9041
F/S114X38I3SW
11/4” x 3/8”
9064
F/S34CA3SW
3/4”
9042
F/S114X12I3SW
11/4” x 1/2”
9063
F/S1CA3SW
1”
9043
F/S114X34I3SW
11/4” x 3/4”
30642
Union
F/S114CA3SW
11/4”
9044
F/S114X1I3SW
11/4” x 1”
9061
MFR#
SIZE
WEBB#
F/S112CA3SW
11/2”
9045
F/S112X12I3SW
11/2” x 1/2”
9069
F/S12UN3SW
1/2”
9109
F/S2CA3SW
2”
9046
F/S112X34I3SW
11/2” x 3/4”
9068
F/S34UN3SW
3/4”
9110
F/S212CA3SW
21/2”
81754
F/S112X1I3SW
11/2” x 1”
9067
F/S1UN3SW
1”
9111
F/S3CA3SW
3”
9048
F/S112X114I3SW 11/2” x 11/4”
9066
F/S114UN3SW
11/4”
9112
F/S2X112I3SW
2” x 11/2”
9072
F/S112UN3SW
11/2”
9113
F/S2X114I3SW
2” x 11/4”
9073
F/S2UN3SW
2”
9114
F/S2X1I3SW
2” x 1”
9074
F/S212UN3SW
21/2”
9115
F/S2X34I3SW
2” x 3/4”
9075
F/S3UN3SW
3”
9116
F/S2X12I3SW
2” x 1/2”
9076
Cross MFR#
SIZE
WEBB#
F/S1CR3SW
1”
84306
F/S112CR3SW
11/2”
77866
F/S2CRS3SW
2”
77868
The VICTOR Propane Equipment Catalog
Reducing Elbow
F/S212X112I3SW 21/2” x 11/2”
9079
F/S212X2I3SW
21/2” x 2”
200488
MFR#
SIZE
F/S3X212I3SW
3” x 21/2”
69452
F/S34X12903SW
3/4” x 1/2” 172849
F/S3X112I3SW
3” x 11/2”
9088
F/S1X12903SW
1” x 1/2” 172938
WEBB#
FITTINGS
116 FITTINGS Forged Steel Fittings, 3000# Socket Weld
Forged Steel Fittings, Threaded
Coupling
45° Elbow
Half Coupling
MFR#
SIZE
WEBB#
MFR#
SIZE
WEBB#
F/S12CO3SW
1/2”
8957
F/S12HCO3SW
1/2”
8969
F/S34CO3SW
3/4”
8958
F/S34HCO3SW
3/4”
8970
F/S1CO3SW
1”
8959
F/S1HCO3SW
1”
8971
F/S114CO3SW
11/4”
8960
F/S114HCO3SW 11/4”
8972
F/S112CO3SW
11/2”
8961
F/S112HCO3SW 11/2”
8973
F/S2CO3SW
2”
8962
F/S2HCO3SW
8974
F/S212CO3SW
21/2”
8963
F/S212HCO3SW 21/2”
8975
F/S3CO3SW
3”
8964
F/S3HCO3SW
8976
2” 3”
Socket Welding Flanges, Class 300 MFR#
SIZE
WEBB#
MFR#
SIZE
WEBB#
W/F12300WNFLG
1/2”
27896
Threaded or Screwed Flanges W/F12300THDFLG 1/2” 27934
W/F34300WNFLG
3/4”
27897
W/F34300THDFLG
3/4”
27935
W/F1300WNFLG
1”
27898
W/F1300THDFLG
1”
27936
Weld Neck Flanges
W/F114300WNFLG 11/4” 27899
W/F114300THDFLG 11/4” 27937
W/F112300WNFLG 11/2” 27900
W/F2300THDFLG
W/F2300WNFLG
W/F212300THDFLG 21/2” 27940
2”
27901
2”
27939
W/F212300WNFLG 21/2” 27902
W/F3300THDFLG
3”
27941
W/F3300WNFLG
3”
27903
W/F4300THDFLG
4”
27942
W/F4300WNFLG
4”
27904
W/F6300THDFLG
6”
27943
W/F5300WNFLG
5”
27905
1/2”
27944
3/4”
27945 27946
W/F6300WNFLG
6”
27906
Blind Flanges W/F12300BLFLG
W/F8300WNFLG
8”
27907
W/F34300BLFLG
W/F10300WNFLG
10”
27908
W/F1300BLFLG
1”
27909
W/F114300BLFLG
11/4” 27947
W/F112300BLFLG
11/2” 27948
W/F12I300WNFLG
12”
Socket Weld Flanges W/F12300SOFLG 1/2”
27915
W/F2300BLFLG
2”
W/F34300SOFLG
3/4”
27916
W/F212300BLFLG
21/2” 27950
W/F1300SOFLG
1”
27917
W/F3300BLFLG
3”
27951
W/F114300SOFLG
11/4” 27918
W/F4300BLFLG
4”
27952
W/F112300SOFLG
11/2” 27919
W/F5300BLFLG
5”
27953
W/F2300SOFLG
2”
27920
W/F6300BLFLG
6”
27954
W/F212300SOFLG
21/2” 27921
W/F8300BLFLG
8”
27955
W/F3300SOFLG
3”
27922
W/F10300BLFLG
10”
27956
W/F4300SOFLG
4”
27923
W/F12I300BLFLG
12”
27957
W/F5300SOFLG
5”
27924
W/F6300SOFLG
6”
27925
W/F8300SOFLG
8”
27926
W/F10300SOFLG
10”
27927
W/F12I300SOFLG
12”
27928
27949
MFR# 3000# F/S14453SE F/S38903SE F/S12453SE F/S34453SE F/S1453SE F/S112453SE F/S2453SE F/S114453SE F/S3453SE 2000# F/S14452SE F/S114452SE F/S3452SE
Reducing Elbow SIZE
WEBB#
1/4”
8700 8689 8702 8703 8704 8706 8707 8705 154532
3/8” 1/2” 3/4”
1” 11/2” 2” 11/4” 3” 1/4”
11/4” 3”
8665 8670 8674
90° Elbow MFR# 3000#
SIZE
WEBB#
F/S14903SE F/S12903SE F/S34903SE F/S1903SE F/S114903SE F/S112903SE F/S2903SE F/S212903SE F/S3903SE 2000# F/S14902SE F/S12902SE F/S2902SE F/S34902SE F/S1902SE F/S114902SE F/S112902SE F/S2902SE F/S212902SE F/S3902SE 90° Street Elbow F/S14S903SE F/S38S903SE F/S12S903SE F/S34S903SE F/S1S903SE F/S114S903SE F/S112S903SE F/S2S903SE
1/4”
8688 8690 8691 8692 8693 8694 8695 8696 8697
1/2”
3/4” 1” 11/4” 11/2” 2” 21/2” 3” 1/4”
8654 1/2” 8656 2” 8661 3/4” 8657 1” 8658 11/4” 8659 11/2” 8660 2” 8661 21/2” 8662 3” 8663 — 3000# 1/4” 8723 3/8” 8724 1/2” 8725 3/4” 8726 1” 8727 11/4” 8728 11/2” 8729 2” 8730
MFR# SIZE WEBB# 3000# F/S1X34903SE 1” x 3/4” 216219 F/S1X12903SE 1” x 1/2” 210687 F/S2X112903SE 2” x 11/2” 206543
Coupling MFR# 3000# F/S14CO3SE F/S38CO3SE F/S12CO3SE F/S34CO3SE F/S1CO3SE F/S114CO3SE F/S112CO3SE F/S2CO3SE F/S212CO3SE F/S3CO3SE
SIZE
WEBB#
1/4”
1” 11/4” 11/2” 2” 21/2” 3”
8732 8733 8734 8735 8736 8737 8738 8739 8740 8741
SIZE
WEBB#
1/4”
180086 222407 180085 187210 110425 200465 184610 223961 187211
3/8” 1/2” 3/4”
Cross MFR# 3000# F/S14CR3SE F/S38CR3SE F/S12CR3SE F/S34CR3SE F/S1CR3SE F/S114CR3SE F/S112CR3SE F/S2CR3SE F/S3CR3SE
3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 3”
Square Head Plug MFR# 3000# F/S14PL F/S38PL F/S12PL F/S34PL F/S1PL F/S114PL F/S112PL F/S2PL F/S212PL F/S3PL
SIZE
WEBB#
1/4”
8828 8829 8830 8831 8832 8833 8834 8835 8836 8837
3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3”
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
FITTINGS
117
Bushing MFR# 3000# F/S14X18BU F/S38X18BU F/S38X14BU F/S12X18BU F/S12X14BU F/S12X38BU F/S34X18BU F/S34X14BU
Tee SIZE 1/4” x 1/8” 3/8” x 1/8” 1/8” x 1/4” 1/2” x 1/8” 1/2” x 1/4” 1/2” x 1/8” 3/4” x 1/8” 3/4” x 1/4”
WEBB# 8851 8853 8852 8856 8855 8854 8860 8859
F/S34X38BU 3/4” x 1/8” 8858 F/S34X12BU 3/4” x 1/2” 8857 F/S1X18BU 1” x 1/8” 8865 F/S1X14BU 1” x 1/4” 8864 F/S1X38BU 1” x 1/8” 8863 F/S1X12BU 1” x 1/2” 8862 F/S1X34BU 1” x 3/4” 8861 F/S114X14BU 11/4” x 1/4” 8870 F/S114X38BU 11/4” x 3/8” 8869 F/S114X12BU 11/4” x 1/2” 8868 F/S114X34BU 11/4” x 3/4” 8867 F/S114X1BU 11/4” x 1” 8866 F/S112X14BU 11/2” x 1/4” 8877 F/S112X38BU 11/2” x 3/8” 8876 F/S112X12BU 11/2” x 1/2” 8875 F/S112X34BU 11/2” x 3/4” 8874 F/S112X1BU 11/2” x 1” 8873 F/S112X114BU 11/2” x 11/4” 8872 F/S2X14BU 2” x 1/4” 8885 F/S2X38BU 2” x 3/8” 8884 F/S2X12BU 2” x 1/2” 8883 F/S2X34BU 2” x 3/4" 8882 F/S2X1BU 2” x 1” 8881 F/S2X114BU 2” x 11/4” 8880 F/S2X112BU 2” x 11/2” 8879 F/S212X14BU 21/2” x 1/4” 8894 F/S212X34BU 21/2” x 3/4" 8891 F/S212X1BU 21/2” x 1” 8890 F/S212X114BU 21/2” x 11/4” 8889 F/S212X112BU 21/2” x 11/2” 8888 F/S212X2BU 21/2” x 2” 8887 F/S3X12BU 3” x 1/2” 8902 F/S3X34BU 3” x 3/4” 8901 F/S3X1BU F/S3X114BU F/S3X112BU F/S3X2BU F/S3X212BU
FITTINGS
Forged Steel Fittings, Threaded
3” x 1” 3” x 11/4” 3” x 11/2” 3” x 2” 3” x 21/2”
8900 8899 8898 8897 8896
MFR# 3000# F/S14T3SE F/S38T3SE F/S12T3SE F/S34T3SE F/S1T3SE F/S114T3SE F/S112T3SE F/S2T3SE F/S212T3SE 2000# F/S14T2SE F/S38T2SE F/S12T2SE F/S34T2SE F/S1T2SE F/S114T2SE F/S112T2SE F/S2T2SE F/S212T2SE F/S3T2SE
SIZE
WEBB#
1/4”
8712 8713 8714 8715 8716 8717 8718 8719 8720
3/8” 1/2” 3/4”
1” 11/4” 2” 2” 2” 1/4” 3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3”
8676 8677 8678 8679 8680 8681 8682 8683 8684 8685
Cap MFR# 3000# F/S14CA3SE F/S38CA3SE F/S12CA3SE F/S34CA3SE F/S1CA3SE F/S114CA3SE F/S112CA3SE F/S2CA3SE F/S212CA3SE F/S3CA3SE
Half Coupling
Reducer Coupling
SIZE
WEBB#
1/4” 3/8” 1/2” 3/4”
8816 8817 8818 8819 8820 8821 8822 8823 8824 8825
1” 11/4” 11/2” 2” 21/2” 3”
MFR# SIZE 3000# F/S14X18R3SE 1/4” x 1/8” F/S38X14R3SE 3/8” x 1/4” F/S38X18RED3SE 3/8” x 1/8” F/S12X14R3SE 1/2” x 1/4” F/S12X38R3SE 1/2” x 3/8” F/S12X38CO3SE 1/2” x 3/8” F/S34X14RED3SE 3/4” x 1/4” F/S34X14R3SE 3/4” x 1/4” F/S34X38R3SE F/S34X12R3SE F/S1X14RED3SE F/S1X12R3SE F/S1X34R3SE F/S114X12R3SE F/S114X34R3SE F/S114X1R3SE F/S112X12R3SE F/S112X34R3SE F/S112X1R3SE F/S112X114R3SE F/S2X12R3SE F/S2X34R3SE F/S2X1R3SE F/S2X114R3SE F/S2X112R3SE F/S2X112CO3SE F/S212X2R3SE F/S212X112R3SE 81756 F/S212X1R3SE F/S3X212R3SE F/S3X2R3SE F/S3X112R3SE F/S3X1R3SE
WEBB# 8755 8756 8757 8759 8758 84324 8763 166093
3/4” X 3/8” 8762 3/4” x 1/2” 8761 1” x 1/4” 8768 1” x 1/2” 8766 1” x 3/4” 8765 11/4” x 1/2”34909 11/4” x 3/4”8771 11/4” x 1” 8770 11/2” x 1/2”34904 11/2” x 3/4”34907 11/2” x 1" 8776 11/2” x 11/4”8775 2” x 1/2” 34923 2” x 3/4” 34925 2” x 1” 34924 2” x 11/4” 8782 2” x 11/2” 8781 2” x 11/2” 84326 21/2” x 2” 81759 21/2” x 11/2”
21/2” x 1” 3” x 21/2” 3" x 2" 3” x 11/2” 3” x 1”
MFR# 3000# F/S14HCO3SE F/S38HCO3SE F/S12HCO3SE F/S34HCO3SE F/S1HCO3SE F/S114HCO3SE F/S112HCO3SE F/S2HCO3SE F/S212HCO3SE F/S3HCO3SE
SIZE
WEBB#
1/4”
1” 11/4” 11/2” 2” 21/2” 3”
8744 8745 8746 8747 8748 8749 8750 8751 8752 110427
SIZE
WEBB#
1/4”
1” 11/4” 11/2” 2” 21/2” 3”
9096 9097 9098 9099 9100 9101 9102 9103 9104 9105
SIZE
WEBB#
1/4”
45475 45525 45478 45494 45512 45528 45482 45498 45516 45486
3/8” 1/2” 3/4”
Union MFR# 3000# F/S14UN3SE F/S38UN3SE F/S12UN3SE F/S34UN3SE F/S1UN3SE F/S114UN3SE F/S112UN3SE F/S2UN3SE F/S212UN3SE F/S3UN3SE
3/8” 1/2” 3/4”
209413 81764 155613 209415 77869
Schedules 40 & 80 Black Pipe MFR# Plain End D/P14BPE D/P38BPE D/P12BPE D/P34BPE D/P1BPE D/P114BPE D/P112BPE D/P2BPE D/P212BPE D/P3BPE D/P4BPE
The VICTOR Propane Equipment Catalog
SIZE 1/4” 3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3” 4”
WEBB# 179384 79878 45484 45500 45518 45533 45488 45504 45522 45474 45508
MFR# Threaded & D/P38BTC D/P12BTC D/P34BTC D/P1BTC D/P114BTC D/P112BTC D/P2BTC D/P212BTC D/P3BTC D/P4BTC
SIZE
WEBB#
Capped Ends 3/8” 45473 1/2” 45490 3/4” 45507 1” 45524 11/4” 45477 11/2” 45493 2” 45511 21/2” 45527 3” 45480 4” 45514
MFR# Plain End D/P14XHBPE D/P12XHBPE D/P34XHBPE D/P1XHBPE D/P114XHBPE D/P112XHBPE D/P2XHBPE D/P212XHBPE D/P3XHBPE D/P4XHBPE
1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3” 4”
FITTINGS
118 FITTINGS Schedule 80 Nipples 1 / 4 ” — 1”
PART# SIZE
WEBB#
NIP14XCLOXH 14541
11/2 21/2 3 31/2 4 41/2 5 51/2 6
WEBB#
PART#
3/8”
CLOSE 2
PART#
1/4”
WEBB#
WEBB#
WEBB# 1”
NIP38XCLOXH 14558
NIP12XCLOXH 14575
NIP34XCLOXH 14592
NIP14X112XH 14542
NIP38X112XH 14559
NIP12X112XH 14576
NIP34X112XH
14593
NIP14X2XH
NIP38X2XH
NIP12X2XH
NIP34X2XH
14594
NIP1X2XH
14543
14560
14577
NIP1XCLOXH 14609 14610
NIP14X212XH 14544
NIP38X212XH 14561
NIP12X212XH 14578
NIP34X212XH
14595
NIP1X212XH 14611
NIP14X3XH
NIP38X3XH
NIP12X3XH
NIP34X3XH
14596
NIP1X3XH
14545
14562
14579
14612
NIP14X312XH 14546
NIP38X312XH 14563
NIP12X312XH 14580
NIP34X312XH
14597
NIP1X312XH 14613
NIP14X4XH
NIP38X4XH
NIP12X4XH
NIP34X4XH
14598
NIP1X4XH
NIP14X412XH 14548
14547
NIP38X412XH 14565
NIP12X412XH 14582
NIP34X412XH
14599
NIP1X412XH 14615
NIP14X5XH
NIP38X5XH
NIP12X5XH
NIP34X5XH
14600
NIP1X5XH
14549
14564 14566
14581 14583
14614 14616
NIP14X512XH 14550
NIP38X512XH 14567
NIP12X512XH 14584
NIP34X512XH
14601
NIP1X512XH 14617
NIP14X6XH
14551
NIP38X6XH
NIP12X6XH
14585
NIP34X6XH
14602
NIP1X6XH
14618
NIP34X7XH
14603
NIP1X7XH
110507
NIP14X8XH
14553
NIP12X8XH
14587
NIP34X8XH
14604
NIP1X8XH
14620
NIP1X9XH
14621
14568
9 10
NIP34X10XH
203165
NIP1X10XH 203164
11
NIP34X11XH
203166
NIP1X11XH 14623
203167
NIP1X12XH 14624
12
11 / 4 ” — 3”
PART#
3 / 4”
7 8
PART#
1/2”
PART#
WEBB#
PART#
WEBB# 11/2”
NIP12X12XH
14591
NIP34X12XH
PART#
WEBB#
PART#
SIZE
11/4”
2”
CLOSE
NIP114XCLOXH14625
NIP112XCLOXH14641
NIP2XCLOXH 14657
NIP114X2XH
NIP112X2XH
NIP2X2XH
WEBB# 21/2”
PART#
WEBB# 3”
NIP212XCLOXH 14672
NIP3XCLOXH 14686
NIP212X3XH
NIP3X3XH
11/2 2 21/2 3 31/2 4 41/2 5 51/2
14626
14642
187215
NIP114X212XH 14627
NIP112X212XH 14643
NIP2X212XH 14658
NIP114X3XH
NIP112X3XH
NIP2X3XH
14628
14644
14659
14673
14687
NIP114X312XH 14629
NIP112X312XH 14645
NIP2X312XH 14660
NIP212X312XH 14674
NIP3X312XH 14688
NIP114X4XH
NIP112X4XH
NIP2X4XH
NIP212X4XH
NIP3X4XH
14630
14646
14661
14675
14689
NIP114X412XH 14631
NIP112X412XH 14647
NIP2X412XH 14662
NIP212X412XH 14676
NIP3X412XH 14690
NIP114X5XH
NIP112X5XH
NIP2X5XH
NIP212X5XH
NIP3X5XH
14632
14648
14663
14677
14691
NIP114X512XH 14633
NIP112X512XH 14649
NIP2X512XH 14664
NIP212X512XH 14678
NIP3X512XH 152712
6
NIP114X6XH
14634
NIP112X6XH
14650
NIP2X6XH
14665
NIP212X6XH
14679
NIP3X6XH
14693
7
NIP114X7XH
14635
NIP112X7XH
225118
NIP2X7XH
14666
NIP212X7XH
210655
NIP3X7XH
192822
8
NIP114X8XH
14636
NIP112X8XH
14652
NIP2X8XH
14667
NIP212X8XH
110508
NIP3X8XH
192823
9
NIP114X9XH
225124
NIP112X9XH
223049
NIP2X9XH
187216
NIP3X9XH
187218
10
NIP114X10XH 187212
NIP2X10XH
14669
NIP3X10XH 110510
NIP2X11XH
187214
NIP3X11XH 187217
NIP2X12XH
14671
NIP3X12XH 14699
NIP112X10XH 223048
11 12
NIP114X12IXH 187213
NIP112X12XH 14656
XH Nipple Sets (1 of each)
Concentric Swedge Nipples XH MFR# NIPCS1X34XH
DESCRIPTION 1” x 3 / 4” NIPPLE CONCENTRIC SWEDGE
WEBB# 187219
MFR# NIP14XCLO-6XH
DESCRIPTION 1/4” x CLOSE-6” NIPPLE SET BLACK XH
WEBB# 73366
NIPCS114X1XH
11 / 4” x 1” NIPPLE CONCENTRIC SWEDGE
187220
NIP38XCLO-6XH
3/8” x CLOSE-6” NIPPLE SET BLACK XH
73367
NIPCS112X114XH 11 / 2” x 11 / 4” NIPPLE CONCENTRIC SWEDGE 187221
NIP12XCLO-6XH
1/2” x CLOSE-6” NIPPLE SET BLACK XH
52875
NIPCS2X114XH
2” x 1 1 / 4” NIPPLE CONCENTRIC SWEDGE
187222
NIP34XCLO-6XH
3/4” x CLOSE-6” NIPPLE SET BLACK XH
52876
NIPCS2X112XH
2” x 1 1 / 2” NIPPLE CONCENTRIC SWEDGE
187223
NIP1XCLO-6XH
1” x CLOSE-6” NIPPLE SET BLACK XH
52877
NIPCS3X2XH
3” x 2” NIPPLE CONCENTRIC SWEDGE
187224
NIP114XCLO-6XH
11/4” x CLOSE-6” NIPPLE SET BLACK XH
93049
NIP112XCLO-6XH
11/2” x CLOSE-6” NIPPLE SET BLACK XH
93050
NIP2XCLO-6XH
2” x CLOSE-6” NIPPLE SET BLACK XH
93051
Eccentric Swedge Nipples XH NIPES2X112XH
2” x 1 1 / 2 ” NIPPLE ECCENTRIC SWEDGE
190099
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
SEALANTS & CHEMICALS Hercules Chemicals
Soft-Set Gasoila Soft-Set is a premium quality, multi-purpose thread sealant, with Teflon. Works with most liquids and gases. Such as: gasoline, petroleum products, natural gases and all plumbing applications, except oxygen. • Non-Toxic, Non-Corrosive • AGA, UL, and NSF listed MFR# GSOSS04 GSOSS08 GSOSS16 GSOPB16 GSOPB16
DESCRIPTION 1/4 Pint 1/2 Pint 1 Pint Gasket, 1 Pint Gasket, 1/4 Pint
WEBB# 77120 77121 79481 202323 185348
FREE ALL Deep Penetrating Oil Free All deep penetrating oil is torch in a can. Use it on all rusty parts, it will loosen them in seconds. Ideal for all applications where you need to loosen rusty parts. MFR# GSOFA06 GSOFA12
DESCRIPTION 6 oz. 12 oz.
WEBB# 185347 95315
RectorSeal Pipe Thread Sealants
MFR# DESCRIPTION #5 Joint Compound REC25551 1/2 Pint REC25431 1 Pint REC25300 1 Quart Tru-Blu with Teflon REC31431 1 Pint T Plus 2 with Teflon REC23431 1 Pint
Teflon Tape DESC. MFR# 1/2” x 520’ HRV017526-144 3/4” x 520’ HRV017566-144
WEBB# 13370 34282
The VICTOR Propane Equipment Catalog
MFR# DESCRIPTION WEBB# Cryotek Anti Freeze A/FGAL Gallon 48610 A/F5GAL 5 Gallon 48611 A/F30GAL 30 Gallon 48612 A/F50GAL 50 Gallon 48613 Pipe Joint Compound HER15-420 Pro Dope, 1 / 2 Pint 11236 HER15-427 Pro Dope, 1 Pint 11237 HER15-510 Grrip, 1/4 Pint 11238 HER15-515 Grrip, 1/2 Pint 11237 Thread Sealants HER15-615 Real-Tuff, 1/2 Pint 11241 HER15-620 Real-Tuff, 1/2 Pint 11242 HER15-625 Real-Tuff, 1 Pint 11243 HER15-630 Real-Tuff, 1 Quart 55504 Roof Cement HER25-405 1 Quart 11259 HER25-410 1 Gallon 11260 Cutting Oil HER40-115 1 Quart, Clear 15255 HER40-120 1 Gallon, Clear 15257 HER40-215 1 Quart, Dark 15254 HER40-220 1 Gallon, Dark 15256 HER40-225 5 Gallon, Dark 15258 HER40-240 55 Gallon, dark 15260 Hand Cleaners HER45-333 Winning Hands Wipes 94920 HER45-304 Hand Cream, 14 oz 54115 Rust Dissolver HER45-400 Iron Ike, 29 oz. 11295 Abrasive Cloth HER45-013 11/2”x10 yds, Meshcloth 56901 HER45-030 11/2”x25 yds, Sandcloth 30308
WEBB# 16882 16883 16884 68533 150352
Never•Seez Lubricant Never•Seez Regular Grade is a superior, anti-seize and extreme pressure lubricant formulated to protect parts against rust, corrosion and seizure. MFR# DESCRIPTION N/SNSBT8 8 oz. Brush Top Can N/SNSBT16 16 oz. Brush Top Can
WEBB# 69087 69088
SEALANTS & CHEMICALS
Gasoila Thread Sealant
119
SERVICE MAN‘S TOOLS
120 SERVICEMAN’S TOOLS Presto–Tap Leak Detection System
Leak Detector
LDS 2000 Products Designed to be installed into regulator pressure taps (1/8” NPT), into a tank-pressure tap between the tank service valve and the regulator, or downstream from the secondstage regulator (appliance valve pressure tap or serviceline shut-off valve pressure tap) for pressure reading purposes without “breaking the system”. Meets NFPA Publications 54 and 58 requirements regarding “excess flow”. Provides an easy and quick method of attaching a water manometer or other testing device to the regulator and at appliances to obtain low-pressure readings.
Dispenser w/Brush
Gallon
MFR# PRTLDS2000
DESCRIPTION Leak Detection System Add-on
WEBB# 244169
PRTLDS2000/BV Add-on w/bleeder valve
244170
PRTLDS2000/TG Test gauge unit (For testing of mobile gauges)
244171
PRTLDS2000/RV Regulator Valve 244172 (For installation throughout the system in regulator and valve pressure taps (foreground))
MFR# TSTLTG4 TSTTLPINTUNLABE TSTBTL8DBRUNPRI TSTSTL16CYLUNPR
8oz. Bottle & Dauber DESCRIPTION All Season, Gallon 16 oz. Bottle w/Brush 8 oz Bottle w/Dauber 16 oz. Bottle w/Spray
WEBB# 184312 184310 184311 184309
Leak Tester Kit MFR# DESCRIPTION WEBB# SJIVGT100 TESTER GAS KIT 202406
Quick Adapter MFR# DESCRIPTION WEBB# PRTRV/QA 1/4 FNPT Quick Adapter 244173
Hercules Leak Detector
Leak Detection Pigtail Products MFR# DESCRIPTION PRT1402 Pigtail – 1/4 MPOL x 12” MNPT
WEBB# 244168
PRT1401 Pigtail – 1/4 MPOL x 12” MPOL
244167
MFR# HER45-801
DESC. 8 oz
WEBB# 11293
PRT6800 300 psi Ambient Temperature Gauge 244174
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
SERVICEMAN’S TOOLS
121
Anderson & Forrester Inc. Gauging Drill Kit — GDK4080 Plastic box contains 41 drill sizes: #40 – 80, and GB3020H tapered broach MODEL# DESCRIPTION ANFGDK4080 Gauging Drill Kit
WEBB# 188739
Tapered Broach — GB3015 Three cornered broach. Tapered from .003” to .013”. A must for cleaning Pilot Orifices. MODEL# ANFGB3015
DESCRIPTION Three Cornered Broach
WEBB# 180504
Gauging Reamer Kit — GRK5000 Have the correct size reamer when you need it. Our kit contains each size in a slim plastic case. MODEL# ANFGRK5000 ANFGR5070 ANFGRK080
DESCRIPTION Gauging Reamer Kit Gauging Reamer, #70, 5 PK Gauging Reamer, #80,
WEBB# 180593 180602 180598
Master Adapter Kit — MIK100 Includes all tools needed to assemble MI100 adapters. MODEL# ANFMIK100 ANFFMI100
DESCRIPTION Master Adapter Kit Universal Adapter
WEBB# 180533 180532
Serviceman’s Orifice Assortment Kit — MIK131LP The MIK131 orifice cabinet contains 23 of those orifices most commonly used. Over 300 orifices in proportion to normal demand. MODEL# DESCRIPTION ANFMIK131LP Orifice Assortment
WEBB# 188738
Master Pilot Orifice Assortment Kit — MIK132LP In one kit you now have 32 of the most needed pilot orifices with over 100 pieces. These are replacement pilot orifices for Penn Baso, Robertshaw, General Controls, Honeywell and White-Rodgers. A must for every efficient serviceman. Cabinet is made of heavy gauge steel with durable baked enamel finish and radius bottom sections for easy removal. MODEL# ANFMI132
DESCRIPTION Pilot Orifice Assortment Kit
WEBB# 180534
LP Gas Pilot Orifice Kit — MIK137LP Special kit consists of nearly 137 pieces. There are 18 popular items included. MODEL# DESCRIPTION ANFMIK137LP Special LP Pilot Master Kit
WEBB# S579699
Serviceman’s Friend — TL051 For use with flow meter and other applications. One end of fitting has 1/8” pipe thread, 1/4” pipe thread and special 5/16” x 32 thread. Opposite end has regular hose fitting, also 1/8” straight pipe thread. Hose can be used on either end. MODEL# ANFTL051
The VICTOR Propane Equipment Catalog
DESCRIPTION Serviceman’s Friend
WEBB# 180578
SERVICEMAN‘S TOOLS
Gas Orifices & Gauging Drills
SERVICE MAN‘S TOOLS
122 SERVICEMAN’S TOOLS Gas Orifices & Gauging Drills
Ridgid
Compression Fittings Break-away type separates upon tightening. MODEL# ANFCF639 ANFCF640 ANFCF641 ANFCF644 ANFCF645 ANFCF642 EMPR1633-2 ANFCF643
DESCRIPTION 1/8” Short Breakaway Nut 3/16” Short Breakaway Nut 1/4” Short Breakaway Nut 3/8” Short Breakaway Nut 7/16” Short Breakaway Nut 1/4” Medium Breakaway Nut 1/8” Long Breakaway Nut 1/4” Long Breakaway Nut
WEBB# 180414 180415 180388
180599 181653 S579187
EMPR2972 1/4” Long Breakaway Nut 181654 EMPR1633-4-2 1/4” x 1/8” Long Breakaway Nut 181729 RBS4590-065 RBS4590-067 RBS4590-069 RBS4590-071 RBS4590-072 RBS4590-816
1/8” Short Breakaway Nut 3/16” Short Breakaway Nut 1/4” Short Breakaway Nut 3/8” Short Breakaway Nut 7/16” Short Breakaway Nut
93031 93030 93028 186719 189070
1/4” Long Breakaway Nut
Orifice Caps MFR# ANFCO400-72 ANFCO401 ANFCO403 ANFCO404 ANFCO406
DESCRIPTION LP, 1/2” Hex, 3/8-40 UNS Blank, 1/2” Hex, 1/2-27 NPT Bored, 1/2” Hex, 3/8-27 UNS Blank, 9/16” Hex, 1/2-27 UNS Blank, 1/2” Hex, 3/8-27 UNS
WEBB# 180416 180419 180421 180422 180424
DESCRIPTION Blank, 1/2” Hex, 1/8-27 NPT Blank, 1/4” Hex, 1/4-28 UNF Blank, 1/2” Hex, 7/16-27 UNS Blank, 3/8” Round, 11/32-32 Special
WEBB# 180541 180544 180546 180549
WEBB#
17019 17020 S397733 17021 17022 194041 150000 88804
RID32895 Wide Roll Pipe Cutter
17024
Pipe Vise RID72037 Tri-Stand Chain Vise
17008
16887 16888 16889 16890 16891 16892 16893 16894 16895 S161857 16909 95189 16910 16911 16912 16913 16914
CO401 Threading Equipment S384354 RID36355 3/8” – 1” Die Set RID67872 1/2” – 1” Oilless Machine 192516
Orifice Hex Plugs MFR# ANFPO505 ANFPO508 ANFPO511 ANFPO518
MODEL# DESCRIPTION Sraight Pipe Wrench RID31000 6” RID31005 8” RID31010 10” RID31015 12” RID31020 14” RID31025 18” RID31030 24” RID31035 36” RID31040 48” RID31045 60” Aluminum Pipe Wrench RID31090 10” RID47057 12” RID31095 14” RID31100 18” RID31105 24” RID31110 36” RID31115 48” Pipe Cutters RID32810 Heavy Duty – 1A RID32820 Heavy Duty – 2A RID32825 3 Wheel Heavy Duty – 2A RID32830 Heavy Duty – 3S RID32840 Heavy Duty – 4S RID32845 3 Wheel Heavy Duty – 4S RID32850 4” – 6” Heavy Duty – 6S RID12831 PVC Pipe Cutter
PO511
Wet/Dry Vac RID96892 16 Gallon
202765
Flaring Tools RID83037 1/8”— 3/4” w/Ratchet RID23332 3/16 ” — 5 / 8”
17087 54831
Tube Cutters RID32915 1 / 8 ” — 1 ” RID31622 1 / 8” — 11/8” RID86127 1 / 4” — 11 / 8” RID32985 Mini Cutter
17069 17065 57823 17054
Anderson & Forrester Inc.
Victor carries a full line of Ridgid Products
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
SERVICEMAN’S TOOLS MODEL# DESCRIPTION FatMax™ Contractor Grade Tools SPT67-077 Screwdriver Set SPT34-130 Long Tape, 100’ SPT33-725 Tape Rule, 11/4” x 25’ SPT33-730 SS Tape, 30’ SPT20-045 Panel Saw SPT20-556 Sharptooth Saw SPT10-799 Utility Knife SPT10-788 Quick Change Utility Knife SPT51-946 Antivibe Hammer
Milwaukee Electric Tools WEBB# 243065 244273 204720 244274 244275 244276 244277 58632 244278
MODEL# DESCRIPTION WEBB# Combination Kit MIL6310-29 18V Sawzall, Hammer Drill, Circular Saw, Worklight & Contractor Bag 243054
18V Cordless Sawzall MIL6515-22 w/2 Batteries, Charger, Two Blade Pack & Steel Carrying Case 154834
Cordless Drill MIL0512-26 Heavy Duty 14.4 Volt w/Worklight 129339
Zag Professional Organizers SPT14325Z Professional, 16”x13”x2” 246371 SPT22001Z Tool Box, 22”x19”x9” 246376
Hatchet Drill MIL6514-21
18 Volt
Worklight MIL49-24-0150 Rechargeable
246651
151289
Reversable Drill MIL1676-6 2 Speed, 1/2” w/Case 13364
Socket Set SPT85-440 82 Piece
210365
Hex Key Set SPT4983 13 Piece, Long Arm
55834
Nut Drivers SPT61-806 1/4” 46378 SPT61-807 5/16” 46380 SPT61-809 3/8” 46382 SPT61-811 1/2” 46384 Ball Pien Hammers SPT54-016 16 oz., Wood Handle 44626 SPT54-024 25 oz., Wood Handle 44628 Rip Claw Hammer SPT51-122 20 oz., Straight, Graphite44620 Adjustable Wrenches w/Stop SPT706LG 6” 44797 SPT708LG 8” 44798 SPT710LG 10” 44799 SPT712LG 12” 44800 Retractable Knives SPT10-299 Uitlity Knife 44593 SPT11-021A Blade Dispenser, 100 pk 44596
The VICTOR Propane Equipment Catalog
Job Site Radio MIL49-24-0220 Worlds Toughest Radio 252136
Circular Saw MIL6320-21
Metal w/Bag
251343
Abrasive Cut-Off Saw MIL6175-6 14”
129835
Deep Cut Portable Band Saw MIL6232-6 43 / 4”
204437
SERVICEMAN‘S TOOLS
Stanley
123
SERVICE MAN‘S TOOLS
124 SERVICEMAN’S TOOLS Rayovac Flashlights & Batteries MFR# DESCRIPTION WEBB# BATIN2 Industrial 2-Cell Flashlight 58520 BATIN3 Industrial 3-Cell Flashlight 58521 BATIN4 Mini Flashlight 58522 BATIN2-KML Industrial 2-Cell w/Magnet 45301 BAT2117 Explosion Proof 185003 BATR2D Roughneck Adjustable Focus 93584 BATR2AA-B Mini Roughneck 206620 BATISL2D-B(2D)Swivel-Lite w/2 D Batteries 193974 BATILJ2AA-BMini Swivel Light 193973 BATV2D-B Value Brights 206621 Batteries — 4 Packs BAT6VHD 6V Square 93585 BAT814-4 C-Cell 40859 BAT813-4 D-Cell 40860 BAT815-4 AA 40861 BAT824-4 AAA 40875
Mini
Industrial C-Cell
Roughneck Mini
Roughneck Adjustable Focus
Propane Flare • Electronic Ignition and proof of flame • Safety feature offers automatic relight attempt — complete shutdown if unsuccessful • Burns up to 529 gallons per hour • Burns liquid or vapor propane • Over 48,000,000 BTU/hr (1/2” Flare) • Flare burner stands 12’ above ground surface • 12’ power cord for 115 volt A.C. • 20’ remote switch cord • Stable triangular base • Setup in 5 minutes
Available in three line sizes 1/4” • 3/8” • 1/2” MFR# PF-12 LPS PF-38 LPS PF-16 LPS
SIZE 1/4” Flare 3/8” Flare 1/2” Flare
BTU/HR 6,900,000 38,000,000 48,300,000
GALS/HR Burns 75 Burns 416 Burns 529
WEIGHT WEBB# 100.5 lbs 103.0 lbs 105.5 lbs
Ari Bee Bopper II Wasp and Hornet Spray Swivel-Light Mini
Swivel-Light
Value Bright
ARI
Turbo Torch MFR# LP2 LP3 Total LP T2 T3 T4 T5
#61011 Beware of the wasp with an attitude. Bee Bopper II will knock him right out of the sky. With Bee Bopper II, you can spray the nest from 20 feet away. Bee Bopper II kills bees and hornets too.
DESCRIPTION Total LP Gas Service Kit Total LP Gas Starter Kit Torch Tips 5/16 ” 3/8” 1/2” 3/4”
WEBB# 24717 24718 24719 24720 24721 24722
MFR# VCT61011
SIZE 14 oz.
WEBB# 193250
Gloves
Match Lighter
MFR# EDM23-173 EDM23-193 EDM31791L BOS238L BOS4104 BOS6563 BOS808 BOS908 BOS10YL BOS810YXL
MFR# WEBB# VCTMC100 184435
Aim & Flame Lighters MFR# VCTAF
DESC. Monkey Grip Winter Monkey Winter Tuf-Duk Lg. Leather Suede Leather Palm Leather Palm w/Cuff 8oz. Brown Jersey 8oz. Flannel Knit Lg. 3-Piece Rainsuit X-Lg. 3-Piece Rainsuit
DESCRIPTION Childproof
WEBB# 181493 181496 181494 45362 45376 45377 45384 42362 45399 45400
WEBB# 184412
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
SERVICEMAN’S TOOLS
125
This kit provides the equipment necessary for checking regulator delivery pressure (low pressure) at the appliances. The basic set contains a 2434A-2 low pressure gauge and a 3 foot — 3/16” O.D. flexible synthetic rubber tube. Adapters are also available.
2434A
Part Number
Description
Webb#
2434A
Test Kit
162472
1328
3/8" OD Adapter
162816
1331
1/2" OD Adapter
162817
1332
5/8" OD Adapter
162818
High Pressure Gauge Adapter 1328
Designed for testing high pressure lines. Adapter has 0 to 300 PSIG gauge. A bleeder valve allows you to bleed down to correct pressure during pressure tests. Part Number
Inlet Connection
Outlet Connection
Pressure Guage Range (PSIG)
Webb#
2962
Soft Nose M. POL
F. POL
0 to 300
162829
Water Manometer Kit 2962
The water manometer kit is especially suited for use with low pressure LP-Gas systems. It is ideal for pressure checks downstream of the low pressure regulator and at the appliances. Part Number
Description
Webb#
1212 KIT
Flexible Tube Water Manometer Kit
162815
1212 KIT
The VICTOR Propane Equipment Catalog
SERVICEMAN‘S TOOLS
Low Pressure Test Set
126 SERVICEMAN’S TOOLS SERVICE MAN‘S TOOLS
UEI Testing Equipment Digital Multimeters DM384, DM383B
DM383B
DM384
Features: • 750 Volts AC and 1000 Volts DC • 10 Amps AC and DC • .01 µ A DC resolution for flame safeguard circuit testing • Frequency to 40 Megahertz • Capacities to 40,000 microfarad • Resistance to 40 Megaohms • Continuity • Diode check function • Autoranging • Analog bar graph • Large, backlit LCD display • MIN/MAX capture and data hold • CE listed CAT III • Five year limited warranty MODEL# U/EDM383B U/EDM384 U/EDM400
DM400
DESCRIPTION Digital Multimeter Tester Digital Multimeter Autoranging Digital Multimeter
Analog Multimeters M110A
M110A
M20
M75A
M1K
Features: • 21 ranges • 600 Volts AC and 300 Volts DC • 2 Megaohm resistance • High resolution DC µ A for flame safeguard testing • Color-coded and mirrored scale plate • Three year limited warranty M20 Features: • 12 ranges • 500 Volts AC and DC • DC milliamps • Fused ohm circuit • Resistance to 50 kilaohms • Color-coded and mirrored scale plate • Three year limited warranty MODEL# U/EM20 U/EM1K U/EM110A U/EM75A
DESCRIPTION Pocket Size Analog Multimeter Pocket Analog Multimeter Analog Multimeter w/Case Pocket Analog Multimeter w/Case
DM400 Features: • 600 Volts AC and DC • 10 Amps AC and DC • Resistance to 40 Megaohms • Autoranging • MIN/MAX capture • Data hold • Continuity • Diode check function • 4000 count resolution • UL listed CAT II • CE listed CAT III • Five year limited warranty
WEBB# 189406 152242 217581
M75A Features: • 17 ranges • 1000 Volts AC and DC • 50 kilaohm resistance • DC millivolt scale allows use of adapters • Color-coded and mirrored scale plate • Three year limited warranty M1K Features: • 15 ranges • 500 Volts AC and DC • DC milliamps • Resistance to 50 kilaohms • Decibel measurements • Color-coded and mirrored scale plate • Three year limited warranty WEBB# 184337 217584 184330 217589
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
SERVICEMAN’S TOOLS
127
Clamp-On Multimeters DL 250 Features: • 400 Amps AC • 600 Volts AC and DC • Resistance to 40 Megaohms • Continuity • Capacities to 10,000 microfarads • Temperature to 750°F (400°C) • .01 µ A DC resolution for flame safeguard circuit testing DL250
MODEL# U/EDL250
DESCRIPTION Digital Clamp-on Multimeter
• Diode check function • Time-stamped record function • Autoranging with manual ranging capability • Data hold • 13/8” Jaw capacity • UL and CE listed CAT III • Three year limited warranty WEBB# 213173
Leak and Pressure Detectors CD200
CD200
EM100A
CD100A
Features: • 50 ppm minimum detection • Long 18” gooseneck for hard to reach areas • Visual leak detection by color coded LED’s • Separate user adaptable alarm for predetermined level detection • Precision sensor detects even the smallest leaks
• “Tip-light” in sensor cap illuminates the search areas • Adjustable tick rate to locate leaks quickly and easily • Fast response time of less than two seconds to 40% LEL • Headphone jack • Three year limited warranty
EM100A
CD100A
Features: • Measures -20° to 20° water gauge (WG) • 0.05” WG resolution below 10” WG • Integral protective boot • Easy to use • Large LCD display • Automatic zero with manual reset • Automatic and manual power-off • Long battery life • Includes 18” tubing and fitting • One year limited warranty
Features: • 50 ppm minimum detection • Long 18” gooseneck for hard to reach areas • “Tip-Light” insensor cap illuminate the search area • Sensor provides accurate detection • Audio and visual tic rate, fully adjustable • Headphone jack • One year limited warranty
MODEL# U/ECD200 U/EEM100A U/ECD100A
The VICTOR Propane Equipment Catalog
DESCRIPTION Gas Leak Detector Electronic Manometer Combustible Gas Leak Detector
WEBB# 217633 193481 217632
SERVICEMAN‘S TOOLS
UEI Testing Equipment (cont.)
128 SERVICEMAN’S TOOLS SERVICE MAN‘S TOOLS
UEI Testing Equipment (cont.)
SGA91AKIT
CO71
Carbon Monoxide Analyzer SGA91A
Carbon Monoxide Detector CO71
Features: • Measures CO (0 to 1999 ppm) • Internal pump continuously pulls gas samples from flue or ambient air • Unique pump standby switch extends battery life and speeds walk-through testing • Flue probe and flexible hose connects easily and securely • Backlit display • Thumb-wheel for easy zero adjustment • Two year limited warranty including sensor
Features: • Measures CO (in ambient) from 0 to 999 ppm • Tri-color LED indicates concentrations at 3 levels complying with residential and work place standards • Auto Zero at turn on • Backlit display • MAX continually updates highest CO reading • Audible Alert triggers above 35 ppm indicating dangerous CO concentration • Three year limited warranty
MODEL# DESCRIPTION WEBB# U/EGA91AKIT Carbon Monoxide Gas Analyzer Kit 184340 U/ECO71 Carbon Monoxide Detector w/Alarm 217940
Millivolt/Temperature Analog Meter MODEL# U/EMTV3A
DESCRIPTION Millivolt Tester
WEBB# 184319
MODEL# U/ETA1K
DESCRIPTION Single Input Temperature Adapter
WEBB# 184335
U/EATT29
K-Type Temperature Probe
184323
U/EATT36
8” Surface Probe w/Handle
221152
U/EATT50
8” Liquid Probe w/Handle
221332
U/EATT59
4” Surface Probe
221333
Accessories
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.fwwebb.com
SERVICEMAN’S TOOLS Combustion and Environmental Analyzers
PCA 25
Oil Burner Combustion Kit
Manometer
Monoxor II
Leakator 10
MFR# DESCRIPTION Capacitor Tester TIF660Y Capacitor Tester TIF660 Capacitor Tester Combustion Analyzers BAC24-8043 Portable Combustion Analyzer, PCA 25 BAC24-7141 #CA40H Combination Analyzer Gas/Oil Burner Combustion Test Kit BAC10-5022 Utility Testing Kit BAC10-5057 CO2 Fluid Bottle, 0 - 60% BAC10-5060 Fluid Oxygen Bottle, 3 Pack Pressure Gauge/Manometer BAC17-7002 Manometer BAC17-0025 Manometer, Blue Fluid BAC17-0026 Manometer Case CO Detector BAC19-7021 CO Detector Kit BAC19-5002 Tube Detector, 12 pack BAC24-7059 Portable CO Detector Kit BAC19-8004 Monoxor® II CO Analyzer w/Case BAC24-0498 Carbon Monoxide Cell BAC11-0121 Envelope Material Filter Leak Detector BAC19-7051 Leakator® 10 Kit, Complete w/Case TIF8800A Gas Detector Refrigerant Electronic Bubble Detector TIF4000A Electronic Sight Glass Psychrometer or Humidity Detector BAC12-7011 Sling Psychometer, +25°F + 120°F Mercury Filled BAC12-0011 Wick Replacement Kit, 4 Pack Thermometer BAC12-7014 Tempoint Thermometer, 1000°F, (6” Stem) TIF7800 Infared Laser Thermometer
Sling Psychrometer
The VICTOR Propane Equipment Catalog
WEBB# 216291 243741 155163 S556623 68938 68941 68942 68924 150725 68925 184961 184960 68936 68915 68934 75564 80817 192930 243742 68945 68949 68923 209395
SERVICEMAN‘S TOOLS
Bacharach
129
PUMPS/COMPRESSORS
130 PUMPS/COMPRESSORS Coro-Flo® Turbine Pumps Stationary Applications Designed specifically for LPG. . . The Corken Coro-Flo® pump was designed for LPG, NH3 and other light liquids. For low-capacity, medium-head pumping, the Coro-Flo pump is the pump of choice. Extremely quiet and free of vibration and pulsation, the Coro-Flo pump provides trouble-free service and long life for volatile liquids such as LPG. The exclusive turbine construction provides smooth continuous flow through the pump case, resulting in higher efficiency and greater capacity and pressure for the same size motor. The one moving part, the impeller, floats on the shaft without contacting adjacent surfaces, thus extending pump life.
F-Model 101 Direct Drive
Simple to service. . .
C-Model w/Close Coupled Motor
The Coro-Flo® pump has been designed for simplicity of inspection and service. The cover can be removed and the impeller and seal serviced without disturbing the piping. The balanced mechanical seal is furnished with its own sleeve, providing extremely reliable service The Coro-Flo pump is listed by Underwriters’ Laboratories, Inc. for use in LP-Gas and anhydrous ammonia service. MFR# DESCRIPTION WEBB#
DS/DL-Model Direct Mounted SPECIFICATIONS Inlet Outlet RPM-60 Hz Max. Differential Press. 50 Hz PSI (Bar) 60 Hz PSI (Bar) Mounting Options Close Coupled Direct Driven (101) V-Belt (103) Direct Mounted Frame (DS/DL) Double Seal Option (Except C-model) Flange Option 11/2” x 1” — 300# (Except C-model) Impeller Material Opt. O-ring Material Opt.: Teflon(r), Viton(r), Ethylene-propylene Seal Seat Material Options: Ceramic Ni-cast iron, SS304, Tungsten Carbide Temperature (min/max) Maximum Driver
10 11/4” NPT 1” NPT 3450 60 (4.1) 70 (4.8) Yes Yes Yes
MODEL 12 13 11/2” NPT 11/2” NPT 1” NPT 1” NPT 3450 3450 75 (5.2) 75 (5.2) 100 (6.9) 125 (8.6) Yes Yes Yes
Yes Yes Yes
14 11/2” NPT 1” NPT 3450 75 (5.2) 125 (8.6) Yes Yes Yes
Dispensing Station/Aerosol/Refrigerant Pumps CRKF10CD Pump f/10
181043
CRKF12CD
Bare Coro-Flo
181044
CRKF14CD
Bare Coro-Flo
181045
CRKDL14
Direct Mount, Lg Frame
181211
CRKDS12CDC Direct Mount, Sm Frame
181216
Dispensing Station Pumps CRKC10S 3/4 HP, 115/230V Remote
181031
CRKC10SB
3/4 HP, Remote Switch, Bypass
181032
CRKC10SM
3/4 HP, 115/230V Switch
181033
CRKC10SMB
3/4 HP, SW Mount & Bypass
181034
CRKC12
1 HP Motor
181035
CRKC12S
1 HP 115/208/230 Remote
181036
CRKC12SB
1 HP Motor, Remote Switch
181037
CRKC12SM
1 HP 115/208/230 Switch
181038
CRKC12SMB
1 HP Kit, SW Mount 3/4 Bypass
181039
Yes
Yes
Yes
Yes
CRKC13
2 HP Motor
212890
Yes
Yes
Yes
Yes
CRKC14
3 HP Motor, SW Mount
104939
Yes
Yes
Yes
Yes
Dispensing Station Accessories CRKB166B1B 1NPT Bypass Valve
181025
CRKB166B75B 3/4 NPT Bypass Valve
181026
Bronze (standard), Ductile Iron, Stainless Steel
Buna N (standard), Neoprene(r), Teflon(r), Viton(r), Ethylene-Propylene Cast Iron (standard), Ni-Resist, Stainless Steel, Tungsten Carbide, Ceramic -25/225°F -32/107°C 5 HP 3.7 KW
-25/225°F -25/225°F -32/107°C -32/107°C 10 HP 10 HP 7.5 KW 7.5 KW
-25/225°F -32/107°C 20 HP 15 KW
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMPS/COMPRESSORS
131 PUMPS/COMPRESSORS
Coro-Flo ® Pumps — Parts Detail Models C9 to C15 CAUTION: Always relieve pressure in the unit before attempting any repairs.
REF# 1.
(a) 3.
PART# 7001-031 NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 1014
(a)
1014-1
(a,b)4. (a,b) 5.
2-246 2-247E 1003-09 1003-091 1003-092 1003-0 1003-01 1003-02 1003-2 1003-21 1003-22 1003-3 1003-31 1003-32 1003-4 1003-41 1003-42 1003-5 1003-51 1003-52 113-CX 1004-1X
2.
(b) 6. 7.
1004-11X 1004-2X 1004-21X 8.
1013 1013-1
The VICTOR Propane Equipment Catalog
DESCRIPTION Hex Hd. Cap Screw Cover (Model 9) Cover (Model 10) Cover (Model 12) Cover (Model 13) Cover (Model 14) Cover (Model 15) Case Clearance Shim (.002” Red) Case Clearance Shim (.003” Green) O-Ring, Case (Except TFE) O-Ring, Case (Except TFE) Impeller, Brass Impeller, Iron Model 9 Impeller, SS Impeller, Brass Impeller, Iron Model 10 Impeller, SS Impeller, Brass Impeller, Iron Model 12 Impeller, SS Impeller, Brass Impeller, Iron Model 13 Impeller, SS Impeller, Brass Impeller, Iron Model 14 Impeller, SS Impeller, Brass Impeller, Iron Model 15 Impeller, SS Seal Assembly Seal Housing, Steel (Except TFE O-rings) Seal Housing, SS (Except TFE O-rings) Seal Housing, Steel (For TFE O-rings Only) Seal Housing, SS (For TFE O-rings Only) Housing Adjustment Shim (.010”) Housing Adjustment Shim (.020”)
REF# (a,b) 9. 10. 11. 12.
PART# 2-224 3442 3444 1002-09 1002-0 1002-2 1002-3 1002-4 1002-5 13. 1914-4 14. 7012-006 SF025E
15. 7002-037 NC087A 16. 1015 (a) 17. 2497 (a) 2497-1 18. 2555 (d)
2556 2557 2895 2896
(c)
4261
DESCRIPTION O-ring, housing Pipe Plug, 1/4” NPT Pipe Plug, 3/4” NPT Case (Model 9) Case (Model 10) Case (Model 12) Case (Model 13) Case (Model 14) Case (Model 15) Nameplate Phillip Hd., 6-32 x 1/4” Type F, Plated Socket Hd. Cap Screw Adapter Ring Woodruff Key, Steel Woodruff Key, SS Motor – 3/4 HP (Models 9,10) Motor – 1 HP (Model 12) Motor – 3 HP Models 14,15) Motor – 3/4 HP Obsolete (Models 9E, 10E) Motor – 11/2 HP Obsolete (Models12E) Motor – 2 HP (Model 13)
NOTES: (a) Included with Seal Assembly 113-CX (b) For Seal and O-ring Material (c) Prior to S.N. PRI166727 Motor Part Number was 3760 (d) Starting with S.N. PW 168290 will be new Motor Frame Size
PUMPS/COMPRESSORS
132 PUMPS/COMPRESSORS Coro-Flo ® Pumps — Parts Detail Models F9C to F15C, FF9 to FF15C and F109 to F115 CAUTION: Always relieve pressure in the unit before attempting any repairs.
REF# 1.
(a) 3.
PART# 7001-031 NC100A 031NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 1014
(a)
1014-1
(a) 4. (a) 5.
2-246 2-247E 1003-09 1003-091 1003-092 1003-0 1003-01 1003-02 1003-2 1003-21 1003-22 1003-3 1003-31 1003-32 1003-4 1003-41 1003-42 1003-5 1003-51 1003-52 113-CX 1004-1X
2.
6. 7.
1004-11X 1004-2X 1004-21X 8.
1013 1013-1
DESCRIPTION Hex Hd. Cap Screw Cover (Model 9) Cover (Model 10) Cover (Model 12) Cover (Model 13) Cover (Model 14) Cover (Model 15) Case Clearance Shim (.002” Red) Case Clearance Shim (.003” Green) O-Ring, Case (Except TFE) O-Ring, Case (TFE) Impeller, Brass Impeller, Iron Model 9 Impeller, SS Impeller, Brass Impeller, Iron Model 10 Impeller, SS Impeller, Brass Impeller, Iron Model 12 Impeller, SS Impeller, Brass Impeller, Iron Model 13 Impeller, SS Impeller, Brass Impeller, Iron Model 14 Impeller, SS Impeller, Brass Impeller, Iron Model 15 Impeller, SS Seal Assembly Seal Housing, Steel (Except TFE O-rings) Seal Housing, SS (Except TFE O-rings) Seal Housing, Steel (For TFE O-rings Only) Seal Housing, SS (For TFE O-rings Only) Housing Adjustment Shim (.010”) Housing Adjustment Shim (.020”)
REF# (a) 9. 10. 11. 12.
PART# 2-224 3442 3444 1002-09 1002-0 1002-2 1002-3 1002-4 1002-5 4206-09 4206-0 4206-2 4206-3 4206-4 4206-5 13. 1914-4 14. 7012-006 SF025E
15. 16. (a) 17. (a) 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28.
DESCRIPTION O-ring, housing Pipe Plug, 1/4” NPT Pipe Plug, 3/4” NPT Case (Model 9) Case (Model 10) Case (Model 12) Case (Model 13) Case (Model 14) Case (Model 15) Case ABSI Flanged (Model Case ABSI Flanged (Model Case ABSI Flanged (Model Case ABSI Flanged (Model Case ABSI Flanged (Model Case ABSI Flanged (Model Nameplate
9) 10) 12) 13) 14) 15)
Phillip Hd., 6-32 x 1/4” Type F, Plated 5002-281 Bearing Retainer Ring 1236 Bearing Cap 1006 Grease Seal 2497-1 Woodruff Key, SS 5102-118 Bearing Retainer Ring 2758 Ball Bearing (was 55605) 5000-261 Bearing Retainer Ring 2497 #5 Woodruff Key, Steel 2497-1 #5 Woodruff Key, SS 1234 Shaft 1234-1 Shaft, SS 3226 Key 2759 Ball Bearing (was 77506) 1010-2 Frame 7002 Soc Head Screw 037NC087A 2158 Grease Zerk 2159 Lubricap
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMPS/COMPRESSORS
133 PUMPS/COMPRESSORS
Coro-Flo ® Pumps — Parts Detail Models DS & DL CAUTION: Always relieve pressure in the unit before attempting any repairs.
REF# 1.
(a) 3.
PART# 7001-031 NC100A 031NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 1014
(a)
1014-1
(a) 4. (a) 5.
2-246 2-247E 1003-09 1003-091 1003-092 1003-0 1003-01 1003-02 1003-2 1003-21 1003-22 1003-3 1003-31 1003-32 1003-4 1003-41 1003-42 1003-5 1003-51 1003-52 113-CX 1004-1X
2.
6. 7.
1004-11X 1004-2X
The VICTOR Propane Equipment Catalog
DESCRIPTION Hex Hd. Cap Screw
REF# PART# 1004-21X 8.
Cover (Model 9) Cover (Model 10) Cover (Model 12) Cover (Model 13) Cover (Model 14) Cover (Model 15) Case Clearance Shim (.002” Red) Case Clearance Shim (.003” Green) O-Ring, Case (Except TFE) O-Ring, Case (TFE) Impeller, Brass Impeller, Iron Model 9 Impeller, SS Impeller, Brass Impeller, Iron Model 10 Impeller, SS Impeller, Brass Impeller, Iron Model 12 Impeller, SS Impeller, Brass Impeller, Iron Model 13 Impeller, SS Impeller, Brass Impeller, Iron Model 14 Impeller, SS Impeller, Brass Impeller, Iron Model 15 Impeller, SS Seal Assembly Seal Housing, Steel (Except TFE O-rings) Seal Housing, SS (Except TFE O-rings) Seal Housing, Steel (For TFE O-rings Only)
1013 1013-1
(a) 10. 11. 12. 13.
14. 15. 15. 16. 17. 17a. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28.
DESCRIPTION Seal Housing, SS (For TFE O-rings Only) Housing Adjustment Shim (.010”) Housing Adjustment Shim (.020”) O-ring, housing Pipe Plug, 1/4” NPT Pipe Plug, 3/4” NPT Case (Model 9) Case (Model 10) Case (Model 12) Case (Model 13) Case (Model 14) Case (Model 15) Nameplate
2-224 3442 3444 1002-09 1002-0 1002-2 1002-3 1002-4 1002-5 1914-4 7012-006 SF025E Phillip Hd., 6-32 x 1/4” 5002-281 Bearing Retainer Ring 7001 Pump Hex Hd, Mounting Bolts 037NC100A 2158 Grease Zerk 1/8” NPT 2159 Lubricap 4298 Mounting Frame – DL 4308 Mounting Frame – DS 5000-281 Retainer Ring 4378 Bearing 3226 Key 4303 Shaft 2497 #5 Woodruff Key, Steel 2497-1 #5 Woodruff Key, SS 2758 Bearing 5102-118 Retainer Ring 1006 Grease Seal 1238 Bearing Cap 5002-281 Retainer Ring
PUMPS/COMPRESSORS
134 PUMPS/COMPRESSORS Coro-Vane® Pumps Bulk Filling, Carousel Filling & Cylinder Filling MFR# DESCRIPTION Stationary Plant Pumps CRK521EF Stationary Coro-Vane
WEBB# 181022
CRK521EG103
Coro-Vane Pump w/Mount
181023
CRK1021EF
Bare Coro-Vane Pump
181013
CRK1021EF103 Coro-Vane Pump w/Mount 284T
181042
Stationary Plant Accessories CRKB177125B Bypass Valve w/1818, 11/4” NPT
181027
CRKB177150
Bypass Valve,11 / 4” NPT
181028
CRKB1772B
Bypass Valve, 2” NPT
181029
Specifications SPECIFICATIONS
MODEL 1021 F1021 F1521 Suction Flange 3” 3” 300 LB ASA 4” 300 LB ASA Discharge Flange 3” 21/2” 300 LB ASA 3” 300 LB ASA RPM-60 Hz 3450 3450 Minimum RPM 420 420 420 Maximum RPM 950 950 950 Minimum Temperature -25° F (-32° C) Maximum Temperature 225° F (107° C) Max. Working Pressure 350 400 400 400 400 PSIG (Bar) (25.2) (28.6) (28.6) (28.6) (28.6) Max. Differential Pressure 125 PSID 125 PSID 125 PSID 125 PSID 100 PSID (8.6 Bar) (8.6 Bar) (8.6 Bar) (8.6 Bar) (6.9 Bar) Suction Flange Option No 2” 4” No No Discharge Flange Option No 21 / 2” 4” No No Internal Relief Yes Yes Yes No No O-Ring Material Options Buna N (standard), Teflon®, Viton®, Neoprene® Seal Seat Material Options Cast Iron (standard), Stainless Steel, Ni-Resist Steel Slip-on Flange Option (suction & discharge) No Yes Yes No No Discharge Flange Option No Yes No No No Cast Steel Option No Yes No No No Maximum Driver 2 HP 10 HP 20 HP 20 HP 30 HP 1.5 KW 7.5 KW 15 KW 15 KW 22 KW C51/F51 1 3/4” 3450 1450 1750
521 21 / 2” 2” 3450 420 950
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMPS/COMPRESSORS
135
Models 521, 522, 1021, 1022, S/N CT115372 and Later
REF# PART# 1162-2 1201-2 (c) 1172-2.5 1172-2 1172-2 (d) 1206-3 (b) 2-234 2-245 2-249 (b) 2-112 1170 1309 1168-6 1168-7 1308-8 1308-9 1166-1X1R 1166-1X2R 1208-1X1R 1208-1X2R 2158 1769 1343 (a,b) 1769-X 1163-2 1209-1 1161-4 1205-4 2754-X 1343 2-128 2-261 2-268
DESCRIPTION CAM (521,522) CAM (1021,1022) FLANGE – 21/2” NPT (321, 521) FLANGE – 2” NPT (322, 522) FLANGE – 2” NPT (321. 521) FLANGE – 3” NPT (1021,1022) 0-RING, FLANGE (321, 322, 521,522) 0-RING, FLANGE – 3” (1021, 1022) 0-RING. FLANGE – 4” (1021,1022) 0-RING, ADJUSTING SCREW CAM KEY (321, 322, 521, 522) CAM KEY (1021, 1022) BLADE – LPG (321, 322, 521, 522) BLADE – NH, (321, 322, 521,522) BLADE – LPG (1021,1022) BLADE – NH, (1021, 1022) ROTOR/SHAFT ASSY. W/2755 (321, 521) ROTOR/SHAFT ASSY. W/2755 (322, 522) ROTOR/SHAFT ASSY. W/2755 (1021) ROTOR/SHAFT ASSY. W/2755 (1022) GREASE ZERK (1 / 8” NPT) BEARING HOUSING RELIEF FITTING (SEAL VENT) SEAL ASSEMBLY SIDEPLATE (321, 322, 521, 522) SIDEPLATE (1021,1022) HEAD (321, 322, 521, 522) HEAD (1021,1022) ROLLER BEARING – COMPLETE RELIEF FITTING (GREASE) 0-RING. SHAFT 0-RING. CASE (321, 322, 521, 522) 0-RING, CASE (1021. 1022)
The VICTOR Propane Equipment Catalog
NOTES: (a) TWO SEAL ASSEMBLIES ARE AVAILABLE (FOR SEAL DETAILS SEE SERVICE MANUAL PAGE C244):1768-X COMPLETE SEAL ASSEMBLY (b) CONSISTING OF: BEARING HOUSING, SEAT ADAPTER PLATE, BEARINGS, RETAINER RING, SEAL AND 0-RINGS. 1769-XR FIELD REPLACEMENT SEAL ASSEMBLY (c) CONSISTING OF: SEAL AND 0-RINGS. (b) FOR SEAL AND 0-RING MATERIAL CODING SEE PAGE A500. (c) OPTIONAL: 1172-1.5 FLANGE – 11 / 2” NPT 1172-1.5S FLANGE – 11 / 2” WELDED 1172-2 FLANGE – 2” NPT 1172-2S FLANGE – 2” WELDED 1172-2.5 FLANGE – 21 / 2” NPT 1172-2.5S FLANGE – 2’ WELDED 1947-1.5 FLANGED E11 –1” NPT 2008-2 FLANGED E11 – 2” NPT (d) OPTIONAL: 1206-3S FLANGE – 3” WELDED 1206-4 FLANGE – 4” NPT 1206-4S FLANGE – 4” WELDED * This page is an excerpt from Corken Service Manual Page C132H
PUMPS/COMPRESSORS
Coro-Vane ® Pumps — Parts Detail*
PUMPS/COMPRESSORS
136 PUMPS/COMPRESSORS Coro-Vane® Truck Pumps MFR# DESCRIPTION Coro-Vane Pump Trucks CRKZ3200 Pump Truck
WEBB# 181234
CRKZ4200
204940
4” Transport
Accessories CRKT166-11.25 11/4” Bypass Valve
181049
Specifications SPECIFICATIONS
Z3200
MODELS Z3200 3” 300# ANSI 2” NPT EI
Suction flange Discharge flange
Z4200
Maximum RPM Minimum temperature Maximum temperature Maximum working pressure Maximum differential pressure Discharge flange open Internal relief valve Steel slip-on flange option
Z4200 4” 300# ANSI 2” Dual NPT
800 -25°F (-32°C) 225°F (107°C) 400 PSIG (28.6 Bar) 125 PSID (8.6 Bar) Yes yes
No Yes
Yes
Yes
Z3200 Performance Chart Differential Pressure
Approximate Delivery on Propane
RPM
PSI
(BAR)
GPM
(LPM)
BHP
(KW)
800 800
50 100
(6.9)
121 110
(460) (420)
6.6 10.6
(4.9) (7.9)
43.4 69.3
(6.0) (9.6)
650 650
50 100
(3.4) (6.9)
98 88
(371) (333)
5.2 8.2
(3.9) (6.1)
42.0 66.3
(5.8) (9.2)
500 500
50 100
(3.4) (6.9)
73 63
(276) (238)
3.8 5.8
(2.8) (4.3)
39.9 60.9
(5.5) (8.4)
Pump Speed
Brake HP Required
Pump Torque Required FT. LBS. (KG/M)
Z4200 Performance Chart Differential Pressure
Approximate Delivery on Propane
RPM
PSI
(BAR)
GPM
(LPM)
BHP
(KW)
800 800
50 100
(3.4) (6.9)
400 360
(1511) (1360)
13.3 26.7
(9.1) (19.7)
88 176
(12.0) (24.3)
650 650
50 100
(3.4) (6.9)
326 283
(1209) (1070)
10.8 21.7
(8.0) (16.1)
87 175
(12.0) (24.3)
500 500
50 100
(3.4) (6.9)
235 200
(888) (756)
8.3 16.7
(6.2) (12.4)
87 175
(12.0) (24.3)
Pump Speed
Brake HP Required
Pump Torque Required FT. LBS. (KG/M)
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMPS/COMPRESSORS
137 PUMPS/COMPRESSORS
Coro-Vane ® Pumps — Parts Detail* Model Z3200
PART NO. 4495-X2R 4242 4232 4231 4417 4438 4439 4439-1 4439-2 4431-X 2754 4432 4441 2-223 2-227 2-262 2158 1343 4243 4241 4262-X 2-234 1172-2
DESCRIPTION ROTORY SHAFT ASSEMBLY CAM BLADE SIDEPLATE BEARING CAP GREASE SEAL BEARING SHIM .002 (RED) BEARING SHIM .010 (BROWN) BEARING SHIM .020 (YELLOW) SEAL ASSEMBLY BEARING OUTER RACE THRUST BEARING ASSEMBLY GREASE SEAL 0-RING-SEAL 0-RING-SEAL SEAT 0-RING - CASE 1/8" NPT GREASE ZERK 1/8" NPT RELIEF FITTING FLANGED ELBOW – 2” CAM KEY BLADE DRIVER (3 REQUIRED) 0-RING – FLANGE FLANGE – 2” NPT
NOTES: (a) SEAL ASSEMBLY INCLUDES SEAL, SEAT, O-RINGS AND GREASE SEAL (b) FOR SEAL AND 0-RING MATERIAL CODING SEE PAGE A500. (c) OPTIONAL: 1172-1.5 FLANGE –11 / 2” NPT 1172-1.5S FLANGE –1 1 / 2 ” WELDED 1172-2S FLANGE – 2” WELDED 1920-3 BLIND FLANGE (d) SLOTS IN BLADES MUST FACE TOWARDS THE DIRECTION OF ROTATION (d) OPTIONAL: 1172-1.5 FLANGE – 11 / 2” NPT 1172-1.5S FLANGE – 11 / 2” WELDED 1172-2 FLANGE – 2” NPT 1172-2S FALNGE – 2” WELDED 1947 FLANGED ELBOW – 11 / 2” NPT
Caution: Always relieve pressure in the units before attempting any repairs.
* This page is an excerpt from Corken Service Manual Page C148A & C149A
The VICTOR Propane Equipment Catalog
PUMPS/COMPRESSORS
138 PUMPS/COMPRESSORS Coro-Vac® Cylinder Purging System
CPS1V
CPS6R
Cylinder and tank air purging prior to LP gas filling is a time consuming, inefficient operation. Even with the newer OPD valves, the Coro-Vac is just as fast, and in most cases, faster than labor-intensive, multiple gas purging. The Corken Coro-Vac system eliminates multiple gas purging. There is no vented gas, therefore no waste and no exposure to employees or the environment. Available in portable and explosion proof models the Coro-Vac is your purging solution. • Simplifies • Does not waste product • Can be used on all types of cylinders and tanks, with or without OPDs • Purge one to ten or more cylinders and tanks • Fewer steps involved for quicker turnaround • No need to vent LP gas to the atmosphere • Prevents initial lean mixture problems • Reduces over-pressure problems due to improper purging MFR# DESCRIPTION WEBB# Vacuum Pumps/Air Purge/Cylinder Evacuation Pumps CRKCPS1V Coro-Vac 1 Cylinder Purge System 193246 CRKCPS1X Coro-Vac 1 Cylinder Explosion Proof Purge System 193248 CRKCPS4V Coro-Vac 2 Cylinder Purge System 193247 CRKCPS4X Coro-Vac 2 Cylinder Explosion Proof Purge System 193249 CRKCPS6R Coro-Vane Rotary Vacuum Pump 206629
Purge Time Estimates NO. OF CYLINDERS 1 – 3 (20 lb.) 1 – 15 (20 lb.) 500 Gal – Tank
CORO-VAC MODEL EST. PURGE TIME* CPS1V/X 2 – 6 minutes CPS4V/X 1 – 15 minutes CPS6R 20 minutes
* Purge times may vary depending upon cylinder valve manufacturer and other restrictive fittings.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMPS/COMPRESSORS
139
The “107” bulk plant gas compressor unit is complete with pressure gauges, steel baseplate, mechanical liquid trap, four-way valve, strainer, interconnecting piping, adjustable driver-slide-base, v-belt drive and beltguard ready to receive an electric motor. This standard unit is typically used for liquid transfer and vapor recovery in applications including rail car and truck loading and unloading. Many options such as ASME liquid traps with Class1, Group D switches and total engineered packages can be provided.
Model 107
MFR# DESCRIPTION Gas Transfer Compressors CRK91-107A (see table below)
WEBB# 181024
CRK291-107 (see table below) CRK491-107 (see table below) CRK691-107 (see table below) SPECIFICATIONS 91
491
MODEL 691
891 HG601BB HG601AA Bore of Cylinder Inches (MM) 3.0 (76.2) 3.0 (76.2) 4.0 (101.6) 4.5 (114.3) 4.5 (113) 6(152) 8 (203) Stroke: Inches (MM) 2.5 (63.5) 2.5 (63.5) 3.0 (76.2) 4.0 (101.6) 4.0 (101.6) 3 (76.2) 3 (76.2) Piston Displacement CFM (m3/HR) Minimum @ 400 RPM4.0 (6.8) 8.0 (13.6) 17.2 (29.2) 29.2 (49.6) 56.6 (96.2) 76.8 (130.5) 138 (234.5) Maximum @ 825 RPM 8.3 (14.1) 16.5 (28.0) 35.5 (60.3) 60.2 (102.3) 113.2 (192.0) — — Maximum @ 1200 RPM — — — — — 230.5 (391.9) 413.8 (703.5) Max. Working Pressure 350 (24.1) 350 (24.1) 350 (24.1) 350 (24.1) 465 (32.1) 365 (25.2) 315 (21.7) Max. Brake Horesepower (KW) 7.5 (5.6) 15 (11) 15 (11) 35 (26.1) 45 (34) 75 (55.9) 75 (55.9) Maximum Rod Load LP (KG) 3600 (1632.9) 3600 (1632.9) 4000 (1814.4) 5500 (3175.2) 7000 (3175.2) 7000 (3175.2) 7000 (3175.2) Max. Outlet Temp. °F (°C) 350 (177) Bare Unit Weight LB (KG) 115 (52.2) 160 (72.6) 260 (117.9) 625 (283.5) 855 (387.8) 828 (375.6) 868 (393.7) Maximum Flow-Propane 50 (11.4) 101 (22.9) 215 (48.8) 36 (82.0) 694 (157..6) 1305 (296.4) 1725 (391.8) GPM (m3/HR) (c) (c) (c) (c) (c) (e) (f) ANSI/DIN Flange Option F91 F291 F491 F691 (d) (d) (d)
The VICTOR Propane Equipment Catalog
291
PUMPS/COMPRESSORS
Compressor
PUMPS/COMPRESSORS
140 PUMPS/COMPRESSORS Piston Assemblies* Model 91 – 691 Models 91, 191, 291, 391, 491, 491-4
SINGLE STAGE
ALL MODELS 90/91.290/291 Piston Assembly No. 1983-X Piston Diameter 3” (7.62 cm) Piston Ring 1772 3 Ring Expander 1775 3 Screw. Soc. Hd. 7002-010 OC100A 4
ALL MODELS 490/491 1985-X 4”(10.16 cm) 1773 3 1776 3 7002-025 OC125A 8
ALL MODELS 690/691 1987-X1 4.5”(11.43cm) 1739 3 1740 3 7002-025 OC125A 8
Caution: Always relieve pressure in the units before attempting any repairs.
Piston Clearance (Cold) Models 590, 691, 691-4
MODEL 91,191, 291, 491 (b)
MINIMUM .020 (.51)
MAXIMUM .044 (1.12)
A91, D91, A191, D191, A291, D291, WA391, D491, 491-3 (b) .025 (.64)
049(1.24)
190, 390, 490, 491 (a)
.000(.00)
.024 (.61)
A190, D190, A390, D390, A490, D491, D490-3, D491-3
.005 (.13)
.029 (.74)
590, 690, W690
.000 (.00)
.012 (.30)
691
.015 (.38)
.027 (.68)
NOTES: (a) For 491 Compressor with flat gasket (b) For 491 Compressor with head o-rings * This page is an excerpt from Corken Service Manual Page E200L
Connecting Rod and Crosshead Assembly Details* All Models, All Specifications Connecting Rod & Crosshead Parts List Description Crosshead Assembly Crosshead Guide Conn. Rod Assembly Connecting Rod Conn. Rod Bearing Wrist Pin Wrist Pin Bushing
Model Number 291 491 691 691 1132-X2 1384-X 1717-X1 3544-X4 2765(h) 2240 4393 2405-X 2405-X 1366(j) 1889-1X 1889-1X 1490-X 1720-X 3785-X1 1889-1 1889 1490 1720 3785 1367 1367 1491 1719 3542 2505 2505 1496 1718 3540 1846-X(a) 1845-X(a) 1495-X(a) 1495-X(a) 3541-X(k) 91 1132-X2
Caution: Always relieve pressure in the units before attempting any repairs.
NOTES: (a) Must be rebored after replacing (0.8754/0.8751 Dia.) (f) Optional Chrome Oxide Piston Rods Only * This page is an excerpt from Corken Service Manual Page E350J &E351L
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMPS/COMPRESSORS
141
All Models 91 and 291 S/N JW47628 and Later Head 90/91
PART NO. 2374-X1 2463-X2 2912-X2 2374-X2 2912-X3 2374 2463 3483-X 3483-1X 3485-X
Head 290/291
Valve Removal Suction Spec 4
Valve Removal Discharge All Specs
DESCRIPTION Head Assy, Spec 4, Model 90,91, D90, D91, A90, A91 Head Assy, Spec 4, Model 290, A290, D290 Caution: Always relieve Head Assy, Spec 4, Model 291, D291 Head Assy. Spec 8, 9, Model 90, 91, D90, D91 pressure in the unit before Head Assy, Spec 7, 78, 8, 9, Model 291, D291 attempting any repairs. Head Model 90,91 Head Model 290, A290, D290 (Obsolete replace by 2912) Suction Valve Assy, Spec 4, 7, 78, 8, 9 Suction Valve Assy, Spec 3 Discharge Valve Assy * This section is an excerpt from Corken Service Manual Page E300L & E301L
All Models 490, 491, All Configurations; Serial No. VK28082 and Later, Spec 4,7,78,8,9; Serial No. YC32239 and later, Spec 3 Spec 4
All Specs
Model: 490, A490, D490, D490-3, T490-3 (S/N VK28082 and later)
PART NO. 1418 1418-2 1478 1481 2-143 2-253 2914 2438-X 2439-1X
DESCRIPTION Valve Gasket, Aluminum Valve Gasket, Iron Gasket, Steel Head Gasket (490, 491, A490, D490, D491, T491) O-Ring, Cover Plate O-Ring (491, D491, T491 Only) Head, Ductile Iron Suction Valve Assy Discharge Valve Assy
* This section is an excerpt from Corken Service Manual Page E322F & 323F
The VICTOR Propane Equipment Catalog
Model: 491, D491, T491 (Prior to S/ N FZ44188.)
Model: 491, D491, T491 (S/N FZ44188 and later.)
PUMPS/COMPRESSORS
Head Assembly Details*
142 ELECTRIC MOTORS ELECTRIC MOTORS
Explosion Proof TEFC (IP54) UL and CSA Approved The WEG line of World Energy Guardian TM Motors are specifically designed to meet or exceed ALL APACT requirements for energy efficiency. Standard Features: • 3 phase, 60 Hz, 208-230/460,460 or 575 V • 143T up to 586/7 cast iron frame • Squirrel cage rotor/Aluminum die cast • Enclosure TEFS (IP54) • All motors supplied with ball bearings except roller bearings in drive end for frames 404T and up, in IV, VI, and VII pole • Class “F” insulation • Temperature rise: Class “B” (80°C) • Service factor: 1.15 (see electrical data for exceptions) • Dimensions according to NEMA standard • NEMA ratings design “B” (except 900RPM Design “A”) • Continuous duty (S1) • 104°F (40°C) ambient temperature
NEMA Frames 14 3T
18 4T 21 3T 21 5T 25 4T 25 6T
DESCRIPTION
WEBB#
10 HP, 3 PH, 1800 RPM
183302
MTR00718XP3E213T
71/2 HP, 3 PH, 1800 RPM, 208V
206666
Mounting 2E 5.500
14 5T 18 2T
MFR# Motor MTR0108XP3E215T
2F 4.000
H
BA
A
0.344 2.250 6.457
5.000 7.750 8.500 10.000
5.500 7.000 8.252 10.000
C
5.157 12.760
D
G
J
K
O
P
T
Keyway Shaft Extension Key Width Depth Length N-W U
Bearings AB
3.500 0.429 1.496 1.654 7.000
7.000
0.187 0.093
1.375
2.250
0.875
6.811
4.500 0.787 1.890 1.969 9.421
8.909
0.250 0.125
1.750
2.750
1.125
8.240
6.142 13.752
4.500 5.500
B
2.750 8.661 0.406 3.500 9.764 0.531 4.250 12.126
5.945 14.862 6.969 15.862 7.402 17.952 8.898 19.450 10.000 23.175 11.732 24.929
AA
d1
DE
OD.E
6205-ZZ
6204-ZZ
6307-ZZ
6206-ZZ
NPT 3/4" A4
1.772 5.250 0.827 2.008 2.185 11.156 10.709
NPT 1"
0.313 0.156
2.375
3.375
1.375
9.252
6.250 0.817 2.520 2.559 12.352 12.224 2.087 0.375 0.187
2.875
4.000
1.625
NPT 11.063 1 1/2"
6308-ZZ 6207-ZZ 6309-C3 6209-Z0C3
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMP ACCESSORIES MFR# KRUH50LP KRUH50G
DESCRIPTION Transfer Compressor, LP Engine Transfer Compressor, Gas Engine
WEBB# 182405 182404
Basic Hose Kit QTY MFR# DESCRIPTION Liquid Transfer Hose 30’ HOS3/4 3/4” LP Hose 2 HOSHY12-12MP 3/4”Hydraulic Coupling, 2 pieces in kit Compressor Inlet Hose (Bobtail to Compressor) 12’ HOS1/2 1/2” LP Hose 2 HOS7661-08MP08TY 1/2” Hydraulic Coupling Compressor Outlet Hose (Compressor to Tank to be Evacuated) 25’ HOS1/2 1/2” LP Hose 2 HOS7661-08MP08TY 1/2” Hydraulic Coupling Fittings 1 RGO3175 3/4” Hose Coupling 1 F/S34CO3SE 3/4” Hose Coupling, 3M 1 RGO7550P 3/4” Transfer Angle Valve 1 RGO3165C 1/4” Bleeder Valve* 1 RGO7590U-10 3/4” Check Lock Adapter* 1 RGO3175B 1/2” Hose Coupling 1 RGO3171A 1/2” Vapor Coupling 1 JOM100-703 1/2” Ball Valve *Install in 7550P for new style Checklok
The VICTOR Propane Equipment Catalog
WEBB# 185604 185576 185581 193208 185581 193208 162687 8735 162760 186852 162762 186853 162686 151448
PUMP ACCESSORIES
Krug Compressor
143
PUMP ACCESSORIES
144 PUMP ACCESSORIES Full Circle Swivel Connectors
SMAC-112LN; 11/2” FNPT 90° Swivel
Additional Notes Temperature range: -40°F to + 350°F Hydrostatic test pressure: 2000 psi for ammonia swivels, 1750 psi for other liquid/liquefied gases. Maximum working pressure: 400 psi for ammonia swivels, 350 psi for other liquid/ liquefied gases Maximum rotatinal speed: 1000 RPM Maximum load on ball bearing at 33 RPM: 5000 lbs for 11/2” and 2” swivels, 2000 lbs for other SMAC prefix swivels, and 1000 lbs for JO prefix swivels U.L. Standard 567
90° Type
Full-Circle offers a complete line of swivel connectors designed for use with thin to viscous liquids and liquefied gases. Straight-through hose end swivels allow the filler valve to rotate 360°. This enables the driver to make tank connections without fighting the hose. It also prevents hose twisting upon reel-up. For bulk-head use, the 90° swivel allows for the use of a shorter transfer hose and enables the operator to safely sweep the hose to one side for proper, out of the way storage. The design is ideally suited for hose reel use as the sealed high load ball bearing can tolerate misalignment problems that could cause product leakage in other swivel types. The tri-directional movement of the three-piece seal package continually compensates for eccentric movement. The Zero maintenance design is of critical importance, especially for leading/unloading arms that must be constructed high in the air for railroad tankcar transfer operation. Safety First All swivels produced by Full-Circle for LP-gas, ammonia, and flammable liquids are listed by the Underwriters Laboratories and are designed and tested in accordance with the U.L.-567 standard, your assurance that the product has been tested to a standard of safety. No Maintenance Design All Full-Circle swivels unitize a sealed high load ball bearing. No greasing or lubrication is ever required. No Rotating Rubber Seals All full-circle swivels incorporate the superseal™ mechanical seal. This patented design allows the seal ring to “float” between two metallic seals. While in operation, the seal ring rotates at one-half the swivel rotational speed. The tridirectional movement of the seal components allows for continuous adjustment due to vibration, misalignment, and temperature extremes. Upon depressurization, the seal spring maintains a constant force on the seal package, preventing product leakage in zero to low pressure environments. Misalignment Minimized All Full-Circle swivels utilize a radial contact ball bearing with extremely high load ratings. The bearing is sealed for life and requires no periodic lubrication. The ball bearing completely supports the rotating portion of the swivel to ensure smooth and easy movement. Field Replacement Components All full-circle swivels are designed so that replacement parts can be installed simply and easily in the field with no special tools required. 90° Type — Same thread size for inlet and outlet Model #
Size
SMAC-3490LN
3/4" x 3/4"
SMAC-190LN
1" x 1"
SMAC-114LN
11/4" x 11/4"
SMAC-112LN
11/2" x 11/2"
SMAC-200LN
2" x 2"
Threads
A
B
Weight
3"
45/8"
63/4 lbs.
31/4"
43/4"
131/8 lbs.
Webb#
Female NPT
Straight Through Type — Same thread size for inlet and outlet Model #
Size
SMAC-34STLN
3/4" x 3/4"
SMAC-1STLN
1" x 1"
Threads
A
B
Weight
51/4"
31/16"
41/2 lbs.
511/16"
47/8"
113/4 lbs.
Webb#
SMAC-114STLN 11/4" x 11/4" Female NPT
Straight Through Type
SMAC-112STLN 11/2" x 11/2" SMAC-200STLN
2" x 2"
Straight Through Hose-End Filler Valve Type — Allows filler valve to rotate 360°
Straight-Through Hose End Filler Valve Type
Model #
Size
Threads
JO-34LN
3/4" x 3/4"
JO-1LN
1" x 1"
Female x Male
A 33/8"
B 21/2"
Weight 11/2 lbs.
Webb# 246583 246584
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMP ACCESSORIES SIZE
Paget Self-Cleaning Strainers
MFR# FLES550-12
1/2” x 12”
WEBB# 187507
FLES575-12
3/4” x 12”
187508
FLES100-12
1” x 12”
187500
FLES125-12
11/4” x 12”
187501
FLES125-18
11/4” x 18”
187502
FLES150-12
11/2” x 12”
187503
FLES200-14
2” x 14”
187505
FLES300-24
3” x 24”
187506
Style B 112, 600#, Threaded, Ductile Iron SC000B112AD Mfr#
Size
Weight
Webb#
SCB112AD-34
3/4"
21/2 lbs
184112
SCB112AD-1
1"
41/2 lbs.
184113
SCB112AD-114
11/4"
7 lbs.
184114
SCB112AD-112
11/2"
8 lbs.
184115
SCB112AD-2
2"
15 lbs.
193217
Style C 103, 600#, Threaded w/Bolted Cover, Ductile Iron SC000C103AD Mfr#
Applications: General purpose Stainless Steel double braided metal flexible gas hose assemblies code rated @ 350 psi available with NPT, ASME flanges, and pipe weld ends. For use typically as a vibration dampener/flexible connector 1/2” — 4” sizes on pump, compressor, and generators. Also available UL536 listed Metal Hose Assemblies suited for Natural Flammable and Combustible Liquid and Gas Service @ 175 psi. All flexible connectors pictured have schedule 80 NPT threaded end with a corrugated stainless hose covered with a double braided stainless steel assembly cover.
Liqua-Tech LP Gas Flowmeter Internationally recognized for our superior flowmeter replacement parts, Liqua-Tech now offers the Model LPM-102 LP Gasliquid flowmeter. Designed for retail sales dispensing units, the LPM102 offers the widest flow range, (3-18 gpm) available in a meter of this type. In addition, the LPM-102 contains all required accessories including vapor eliminator, strainer and differential valve. MFR# DESCRIPTION SIZE LIQLPM102 1 Gal. Register 3/4”
WEBB# 182604
2”
The VICTOR Propane Equipment Catalog
Size
Weight
2"
20 lbs.
SCSC103AD-3
3"
41 lbs.
4"
100 lbs.
Webb# 202666
Style A 105, 300#, Flanged, Ductile Iron SC000C103AD Mfr#
Size
Weight
2"
39 lbs.
Webb#
SCSSC0300A105AD
3"
65 lbs.
S497139
SCSSC0400A105AD
4"
130 lbs.
S497138
PUMP ACCESSORIES
Flex HoseHOSE Flex Connectors FLEX
145
146 PUMP ACCESSORIES PUMP ACCESSORIES
Power Rewind Reels with Bottom-Mounted Guidemaster To handle single 1” or 11/2” I.D. hose
Series PBGMB The Hannay Series PBGMB hose reel is designed specifically for open-deck or compartment mounting, especially when recovery is of an angle other than straight off the reel. Rewind: Choose chain and sprocket drive powered by an electric, hydraulic, or compressed air motor. Gear-driven mechanism with pinion shaft brake can be specified as auxiliary crank rewind on power rewind reels, at extra cost. Brakes & Locks: These reels are supplied with a strap brake. Other brake and locking devices may be specified.
Series PBGMB
Inlet: Standard inlet is 90° ball bearing swivel joint with 11/2” female NPT threads. Outlet: Standard outlet is flanged riser with 11/2” female NPT threads. Standard inlet, outlet riser, and hub assembly are steel.
Other sizes and/or threads can be furnished and must be specified. Operating Pressures and Temperatures: These reels operate at pressures to 350 psi (24 bar) and handle product temperatures from -40° F to +350° F (-40° C to + 177° C).
Reels to operate at other pressures and temperatures can be furnished at extra cost.
Dimensions and Capacities
Hose Capacity of Reel feet m.
Model #
Reel Dimensions Inches mm.
I.D. (in) 1" 11/2" A I.D. (mm) 25.4 38.1 For Power Rewind S e e N o t e 2 O.D. (in) 1.5" 2.16" O.D. (mm) 38.1 54.8 125 50 PBGMB 24-23-24 21 45.7 15.2 533.4 150 75 PBGMB 30-23-24 27.5 45.7 22.9 698.5 200 110 PBGMB 28-25-26 27.5 61.0 33.5 698.5
B
C
D
E
F Elec.
F Air.
F Hyd.
G
15.5 393.7 22 558.8 22 558.8
10.5 266.7 10.5 266.7 10.5 266.7
20.5 520.7 20.5 520.7 25.5 647.7
22.75 577.9 22.75 577.9 24.75 628.7
29.25 743.0 35.75 908.1 33.75 857.3
28.25 717.6 34.75 882.7 32.75 831.9
28.25 717.6 34.75 882.7 32.75 831.9
23.5 596.9 23.5 596.9 27.88 708.2
Specifications subject to change Notes:
H
J
12.12 51 307.8 1295.4 12.12 51 307.8 1295.4 15.5 52 393.7 1320.8
K
L
39.75 1009.7 43 1092.2 42 1066.8
33 838.2 35.25 920.8 35.25 895.4
Approx Weight lb. kg. NET SHIP
160 73 170 77 173 78
Webb#
185 84 200 91 203 92
HD = Hydraulic Rewind – Not supplied with control valve.
3. Dimension J is maximum, with fully extended Guidemaster in operating position. Dimension K is maximum, with fully extended Guidemaster in traveling position opposite rewind motor, as shown in dimensional drawing. Dimension L is maximum, with fully extended 2. When ordering power rewind models, prefix model number with: Guidemaster in travelling position on same side as rewind motor. A = Air Rewind – Supplied with control valve and hose. (The telescoping feature of the Guidemaster permits each of these dimensions to be reduced up to 4”.) Maximum distance from frame of E = Explosion Proof Electric Rewind (1/2 HP) – Supplied with exploreel to outside edge of Guidemaster locked in traveling position is 11”. sion proof switch, solenoid and junction box. 1. Upon request, reels can be supplied with drum lengths other than shown and with disc sizes in other diameters.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
PUMP ACCESSORIES
147
MA™ Series Meters MA-4™/MA-5™ MA-4 Meters in Class 10 construction are designed specfically for LPG motor fuel applications (UL Listed): • Capacity: 30 GPM (115 L/min.) • Choice of 11/2” standard and 2” optional companion flanges. MA-5 Meters in Class 10 construction are designed for LPG truck and high speed LPG motor fuel applications (UL Listed) • Capacity: 60 GPM (225 L/min.) • Choice of 11/2” standard and 2” optional companion flanges.
MA-4-CX-10
MA-7™ MA-7 Meters in Class 10 construction are designed for LPG truck and bulk loading applications (UL Listed). • Capacity: 100 GPM (380 L/min.). • Class 12 construction for NH3 (Anhydrous Ammonia) service available upon request. • Choice of 2” NPT standard, 11/2” optional companion flanges. MA-15™ MA-15 Meters in Class 10 construction are designed for LPG bulk delivery truck and bulk loading applications (UL Listed). • Capacity: 200 GPM (760 L/min.) • Standard 3” inlet, 2” outlet with choice of NPT, BSPT or steel welding flange (3” outlet optional).
MA-7-GY-10 Model #
Description
MA-4+ MA-5+ MA-7+ MA-15+
350 PSI 21 BAR 2068 kPa
Maximum Nominal Flow Rate
Standard Flange Size Primary Material
30 GPM (113 L/min.)
11/2" NPT
60 GPM (227 L/min.)
11/2"
100 GPM (380 L/min.)
2"
200 GPM (757 L/min.)
3"
Aluminum
Model Description Chart – Example shown is meter model MA-15-GY-10
The VICTOR Propane Equipment Catalog
Webb#
251204
PUMP ACCESSORIES
Positive Displacement Meters
VAPORIZORS
148 VAPORIZORS Direct Fired LPG Vaporizers A propane vaporizer is actually a boiler. Instead of boiling water, it boils propane. It may sound strange that heat is required to vaporize propane when propane will boil at -44 F, but, when propane vaporizes by expansion alone, it causes a refrigeration action. In applications with high propane demand, the uncontrolled vaporization would freeze valves and burner nozzles. Therefore, heat is required to offset the refrigeration action. Direct fired vaporizers use a portion of the propane they vaporize to supply the heat for the vaporization process. AES direct fired vaporizers can be used to vaporize all forms of LPG (Liquefied Petroleum Gas), including Propane, Butane, Propylene, etc. • For Propane, Butane, & other LPG • Two-Stage Burner • Dual Liquid Level Control • Piezo Ignitor MFR#
DESCRIPTION
DIMENSIONS
WEBB#
ALTAE-50 ALTAE-80
50 Gal LP 80 Gal LP
17”D x 14” W x 59” H 17”D x 14” W x 67” H
203924 203925
17”D x 14” W x 76” H
203926
ALTAE-120 120 Gal LP
Comparative Thermal Value of Fuels Natural Gas .................................................. 100,000 BTU’s =1 Therm Fuel Oil......................................................... 42 Gallons = 1 barrel
Gas Conversion Factors 1 Cubic Foot (CF) ......................................... Approximate 1,000 BTU’s 100 CF ......................................................... 100,000 BTU’s 1 Therm ....................................................... 100,000 BTU’s 10 Therms ................................................... 1 Decartherm (DTH) 1 DTH .......................................................... 1,000,000 BTU’s 1 DTH .......................................................... 1 MM BTU
Approximate Conversion Propane/Gallon ............................................ 91,500 BTU’s = .915 Therms/Gallon Butane/Gallon .............................................. 103,000 BTU’s = 1.03 Therms/Gallon #2 Heating Oil/Diesel/Gallon ........................ 138,500 BTU’s = 1.385 Therms/Gallon #6 Fuel Oil/Barrel ......................................... 6,350,000 BTU’s = 63.5 Therms/Gallon Coal (Short Ton) .......................................... 21,900,000 BTU’s = 219 Therms/Short Ton 1 Truck & Trailer of Propane (9,300 Gallons)= 8,510 Therms 1 Truck & Trailer of Butane (9,300 Gallons) = 9,274 Therms 1 Truck & Trailer of Diesel (8,000 Gallons) = 11,080 Therms 1 Truck & Trailer of #6 Fuel (7,000 Gallons) = 10,500 Therms
Convert Cents/Gallon to $/MM BTU Multiply Cents/Gallon by: Ethane ......................................................... 15.24 Gallons/MM BTU Propane ....................................................... 10.93 Gallons/MM BTU Normal Butane ............................................. 9.71 Gallons/MM BTU Iso-Butane ................................................... 10.12 Gallons/MM BTU Mixed Butane (75/25) .................................. 9.81 Gallons/MM BTU Natural Gasoline .......................................... 8.00 Gallons/MM BTU #2 Oil ........................................................... 7.22 Gallons/MM BTU
Convert $/Bbl to $/MM BTU Divide $Bbl by: #6 Oil ........................................................... 6.35 MM BTU/Barrel #6 Oil ........................................................... 151,190 MM BTU/Gallon To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
VAPORIZORS
149
What are LPG Vaporizers? LPG vaporizers are actually boilers. Instead of boiling water, they boil propane, butane, or another LPG (Liquefied Petroleum Gas). It may sound strange that heat is required to vaporize LPG when propane will boil at -44°F and butane at 32°F, but, when LPG vaporizes by expansion alone, it causes a refrigeration action. In applications with high LPG flow, the uncontrolled vaporization would freeze valves and burner nozzles. Therefore, controlled heat is required to offset the refrigeration action.
Standard Features and Options • Steel burner tube. • LPG vapor tube with welded heat transfer fins, rated st 250 psig @ 650° F. • Designed and manufactured per ASME Pressure Vessel Code, Section VIII, Division 1 and NFPA 58. • Electronic flame safeguard(WB-450 and higher). • Water circulation pump with internal diffuser. • All models are FM approved. • Liquid carryover protection. • UL listed Safety Pressure Relief Valve. • UL listed Solenoid Valve (liquid inlet). • Vaporizer control panel with first outage annunciator. • Factory primed, painted and tested. Options: • • • • • Low profile design: Standard on WB-200 to WB-350, optional for WB-450 to WB 550
IRI burner configuration ASME “S” stamp Custom control panels and system integration Spare parts kits and service aggreements Enlarged control room
Specifications, WB-200 to WB-550 Specifications Nominal Vaporization Capacity Water Tank Capacity
WB-200 200
gph gal
Burner Design Design Temperature Design Pressure Liquid Inlet Connection Vapor Outlet Connection Electrical Required Standard Dimensions, Width Weight
WB-250 250 160
WB-350 350
Venturi Type, Eclipse or similar °F psig
in. (mm) lbs. (kg)
WB-450 450
WB-550 550
240 Forced Draft Power Burner with Electric Blower, Pyronics PITB or similar
650 250 1" FNPT 2" MNPT AC 110 V 60 Hz, 15 A, 1-Ph AC 220 V 60 Hz, 15 A, 1-Ph 39 (990) 66 (1680) 3200 (1450) 4600 (2090)
Dimensions Standard Dimensions Dimension in inches (mm)
W
L
H
9 37 WB-200, WB-250, WB-350 (93991) (29 515) (940) WB-450, WB-550
The VICTOR Propane Equipment Catalog
V
A
B
C
D
E
F
Concrete Slab
39 69 39 31 30 80 43 12’6" X 5’6" (991) (1753) (991) (788) (762) (2032) (1093) (3.80M X 1.70M)
72 135 90 50 82 66 25 36 112 81 14’ x 7’6" (1829) (3429) (2286) (1270) (2083) (1677) (635) (915) (2845) (2058) (4.30m x 2.30m)
VAPORIZORS
Water Bath LPG Vaporizers
APPENDIX A
150 APPENDIX A C.3.2 Requalification (Including Retesting) of DOT Cylinders.* C.3.2.1 DOT rules prohibit cylinders from being refilled, continued in service, or transported unless they are properly qualified or requalified for LP-Gas service in accordance with DOT regulations. C.3.2.2 DOT rules require a careful examination of every cylinder each time it is to be filled, and it must be rejected if there is evidence of exposure to fire, bad gouges or dents, seriously corroded areas, leaks, or other conditions indicating possible weaknesses that might render it unfit for service. The following disposition is to be made of rejected cylinders: (a) Cylinders subjected to fire are required to be requalified, reconditioned, or repaired in accordance with C.3.3 or permanently removed from service except that DOT 4E (aluminum) cylinders must be permanently removed from service. (b) Cylinders showing serious physical damage or leaks or showing a reduction in the marked tare weight of 5 percent or more are required to be retested in accordance with C.3.2.4(a) or (b) and, if necessary, repaired in accordance with C.3.3. C.3.2.3 All cylinders, including those apparently undamaged, are required to be periodically requalified for continued service. The first requalification for a new cylinder is required within 12 years after the date of manufacture. Subsequent requalifications are required within the periods specified under the requalification method used. C.3.2.4 DOT regulations permit three alternative methods of requalification for most commonly used LP-Gas cylinders (see DOT regulations for permissible requalification methods for specific cylinder specifications). Two use hydrostatic testing, and the third uses a carefully made and duly recorded visual examination by a competent person. In the case of the two hydrostatic test methods, only test results are recorded, but a careful visual examination of each cylinder is also required. DOT regulations cite in detail the data to be recorded for the hydrostatic test methods, the observations to be made during the recorded visual examination method, and the marking of cylinders to indicate the requalification date and the method used. The three methods are outlined as follows: (a) The water jacket-type hydrostatic test is permitted to be used to requalify cylinders for 12 years before the next requalification is due. A pressure of twice the marked service pressure is applied, using a water jacket (or the equivalent) so that the total expansion of the cylinder during the application of the test pressure can be observed and recorded for comparison with the permanent expansion of the cylinder after depressurization. The following disposition is made of cylinders tested in this manner: (1) Cylinders that pass the retest and the visual examination required with it (see C.3.2.4) are marked with the
date and year of the test (example: “6-90,” indicating requalification by the water jacket test method in June 1990) and are permitted to be placed back in service. (2) Cylinders that leak, or for which the permanent expansion exceeds 10 percent of the total expansion (12 percent for Specification 4E aluminum cylinders), must be rejected. If rejected for leakage, cylinders are permitted to be repaired in accordance with C.3.3. (b) Cylinders are requalified for seven years before the next requalification is due. A pressure of twice the marked service pressure is applied, but no provision is made for measuring total and permanent expansion during the test outlined in C.3.2.4(a). The cylinder is carefully observed while under the test pressure for leaks, undue swelling, or bulging indicating weaknesses. The following disposition is made of cylinders tested in this matter: (1) Cylinders that pass the test and the visual examination required with it (see C.3.2.4) are marked with the date and year of the retest followed by an S (Example: 8-91S, indicating requalification by the simple hydrostatic test method in August 1991) and are permitted to be placed back in service. (2) Cylinders are requalified developing leaks or showing undue swelling or bulging must be rejected. If rejected for leaks, cylinders are permitted to be repaired in accordance with C.3.3. (c) The recorded visual examination is permitted to be used to requalify cylinders for five years before the next qualification is due provided the cylinder has been used exclusively for LP-Gas commercially free of corroding components. Inspection is to be made by a competent person, using as a guide the CGA Standard for Visual Inspection of Steel Compressed Gas Cylinders (CGA Pamphlet C-6), and recording the inspection results as required by DOT regulations. The following disposition is to be made of cylinders inspected in this manner: (1) Cylinders that pass the visual examination are marked with the date and year of the examination followed by an E (Example: 7-90E, indicating requalification by the recorded visual examination method in July 1990) and are permitted to be placed back in service. (2) Cylinders that leak, show serious denting or gouging, or excessive corrosion must be either scrapped or repaired in accordance with C.3.3. C.3.3 Repair of DOT Cylinders. Repair of DOT cylinders is required to be performed by a manufacturer of the type of cylinder to be repaired or by a repair facility authorized by DOT. Repairs normally made are for fire damage, leaks, denting, and gouges and for broken or detached valve-protecting collars or foot rings.
* This page is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX A
151
CAUTION: • Do not remove seals on valves before being properly instructed on how to initially fill a vacuum pre-purged propane tank. • Do not let any air enter the propane tank. If air is allowed in the tank before the pressure is normalized, it must be re-purged with propane vapor in accordance with NFPA Pamphlet #58 and government regulatory requirements. • Do not remove cap from fill valve until the vacuum has been neutralized. Begin filling through the service valve (a/k/a the multivalve) for the first fill or at least until the vacuum is neutralized. • Do not open the outage valve until the pressure in the tank has normalized or a positive pressure has been achieved in the tank. • The presence of a vacuum in the tank does not eliminate the need for the introduction of methanol into the tank. • Never prepare the propane tank for service on a customer’s property, but always at the bulk plant site or some other safe location. 1) Verify that a vacuum exists in the tank. 2) Remove the seal wrap from the service valve and verify that the service valve hand wheel is tightly closed. 3) Connect a vacuum pressure gauge to the service valve outlet connection and open the hand wheel. 4) Visually check the vacuum pressure gauge dial for the presence of a vacuum. 5) Close the service valve and disconnect the vacuum pressure gauge. NOTE: If the vacuum is not in accordance with NPGA Safety Bulletin No. 133-89(a), the container must be re-purged with propane vapor. 6) Add methanol to the propane tank by connecting a hose to the POL outlet of the service valve. 7) Submerge the other end of the hose in a safety container that has been filled with the required measure of methanol. 8) Gradually open the service valve and the methanol will be drawn into the tank to partially fill the vacuum that exists. 9) To prevent air from getting into the propane tank, close the service valve as soon as the measured amount of methanol has been removed from the safety container. 10) Disconnect the methanol hose from the POL of the service valve. The VICTOR Propane Equipment Catalog
11) Connect the propane fill hose to the POL connector on the service valve. 12) Open the service valve and start to fill the tank with propane. CAUTION: After the tank pressure has been normalized**, close the outage valve (if it was opened after the pressure was normalized), the service valve and the fill hose valve. NOTE: ** The appropriate amount of propane to normalize the vacuum pressure in the tank will vary depending on the volume of the tank. If liquid is used, 1 to 4 gallons of propane is required for all tanks up to 1000 gal. water capacity. If vapor is used, wait until there is no longer an audible transfer of vapor from the filler hose to the tank. 13) Bleed off the fill connector pressure and disconnect. THE TANK HAS NOW BEEN PREPARED FOR SERVICE. • To transport the tank after preparation process, remove all propane gas in the tank in excess of the amount of propane permitted to be transported under applicable regulations, including those of the U.S. Department of Transportation. • Once the tank has been safely set for service, you may continue the filling process through the fill valve by removing the seal and cap of the fill valve and using your normal safe filling procedures. CAUTION: The initial fill must be to the maximum allowable liquid level to counteract the possible depletion of ethyl mercaptan in the tank. • If you did not do so earlier, you may also inject methanol into the tank at this point by including an injection device in your fill line. • Future fillings should be made through the fill valve.
APPENDIX A
Filling Instructions for the Vacuum Pre-Purged Propane Tank
APPENDIX A
152 APPENDIX A Liquified Petroleum Gas Code* Storage Within Residential Buildings.
5.4.2 Protection of Cylinders.
Storage of cylinders within a residential building, including the basement or any storage area in a common basement storage area in multiple-family buildings and attached garages, shall be limited to cylinders each with a maximum water capacity of 2.7 lb (1.2kg) and shall not exceed 5.4-lb (2.4-kg) aggregate water capacity for smaller cylinders per each living space unit. Each cylinder shall meet DOT specifications.
5.4.2.1 Cylinders at a location open to the public shall be protected by either of the following: (1) An enclosure in accordance with 3.3.6(a) (2) A lockable ventilated metal locker or rack that prevents tampering with valves and pilferage of the cylinder
5.4 Storage Outside of Buildings. Location of Storage Outside of Buildings. Storage outside of buildings for cylinders awaiting use, resale, or part of a cylinder exchange point shall be located as follows. 5.4.1.1 At least 5 ft (1.5 m) from any doorway or opening in a building frequented by the public where occupants have at least two means of egress as defined by NFPA 101, Life Safety Code. For buildings, or sections of buildings, having only one means of egress, at least 10 ft from the doorway or opening. 5.4.1.2 At least 20 ft from any automotive service station fuel dispenser. 5.4.1.3 In accordance with Table 5.4.1.3 with respect to the following: (1) Nearest important building or group of buildings (2) Line of adjoining property that may be built upon (3) Busy thoroughfares or sidewalks (4) Line of adjoining property occupied by schools, churches, hospitals, athletic fields, or other points of public gathering (5) Dispensing station
Exception: Cylinders in the filling process shall not be considered to be in storage.
Table 5.4.1.3 Distances from Cylinders in Storage and Exposures HORIZONTAL DISTANCE TO . . . QUANTITY OF LP-GAS STORED (1) & (2) (3) & (4) (5) LB KG FT M FT M FT M £720 £227 0 0 0 0 5 1.5 721 to 2500 227+ to 1134
0
0
10
3
10
3
2501 to 6000 1134+ to 2721
10
3
10
3
10
3
6001 to 10,000 2721+ to 4540
20
6.1
20
6.1
20
6.1
25
7.6
25
7.6
25
7.6
>10,000
>4540
5.4.2.2* Protection against vehicle impact shall be provided in accordance with good engineering practice where vehicle traffic normally is expected at the location. 5.4.3 Alternate Location and Protection of Storage. Where the provisions of 5.4.1 and 5.4.2.1 are impractical at construction sites or at buildings or structures undergoing major renovation or repairs, alternate storage of cylinders shall be acceptable to the authority having jurisdiction. 5.5* Fire Protection. Storage locations, where the aggregate quantity of propane stored is in excess of 720 lb (327 kg), shall be provided with at least one approved portable fire extinguisher having a minimum capacity of 18 lb (9.2 kg) dry chemical with B-C rating. The required fire extinguisher shall be located no more than 50 ft (15 m) from the storage location. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
Use of Liquid Volume Correction Factors, Table F.3.3. F.4.1 To correct the observed volume in gallons for any LP-Gas (the specific gravity and temperature of which is known) to gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the specific gravity and temperature as described in F.3.3. (b) Multiply the gallons observed by this correction factor to obtain the gallons at 60°F (16°C).
Example: A container has in it 4055 gal of LP-Gas with a specific gravity of 0.560 at a liquid temperature of 75°F. The correction factors in the 0.560 column are 0.980 at 76°F and 0.983 at 74°F, or, interpolating, 0.9815 for 75°F. The volume of liquid at 60°F is 4055 x 0.9815, or 3980 gal. F.4.2 To determine the volume in gallons of a particular LP-Gas at temperature t to correspond with a given number of gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the LP-Gas, using the column for its specific gravity and reading the factor for temperature t. (b) Divide the number of gallons at 60°F (16°C) by this correction factor to obtain the volume at temperature t.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX A
153
Example: It is desired to pump 800 gal (3.03 m3) at 60°F (15.5°C) into a container. The LP-Gas has a specific gravity of 0.510, and the liquid temperature is 44°F. The correction factor in the 0.510 column for 44°F is 1.025. Volume to be pumped at 44°F is 800 / 1.025 = 780 gal (2.95 m3).
F.5 Maximum Liquid Volume Computations. F.5.1 Maximum Liquid LP-Gas Content of a Container at Any Given Temperature. F.5.1.1 The maximum liquid LP-Gas content of any container depends on the size of the container, whether it is installed above ground or under ground, the maximum permitted filling limit, and the temperature of the liquid [see Tables 4.4.2.2(a), (b), and (c).] V
F.5.1.2 The maximum volume fraction t (in percent of container capacity) of an LP-Gas at temperature t, having a specific gravity G and a filling limit and weight percent filling limit of L, is computed by use of the following formula:
Vt =
L ÷F G
or:
Vt =
L Gx F
where:
Vt = percent of container capacity that can be filled with liquid L = maximum permitted filling limit by weight (see Table4.4.2.1) G = specific gravity of particular LP-Gas F = correction factor to correct volume at temperature t to 60°F (16°C) Example: The maximum liquid content, in percent of container capacity, for an aboveground 30,000-gal (114-m3) water capacity container of LP-Gas having a specific gravity of 0.508 and at a liquid temperature of 80°F (27°C) is computed as follows: From Table 4.4.2.1, L = 0.45, and from Table F.3.3, F = 0.967. Thus,
V80 =
0.45 0.508 x 0.967
= 0.915 (91%) or 27,300 gal (103 m3)
ther gauge provided that the fixed maximum liquid level is installed or the variable gauge is set to indicate the volume equal to the maximum permitted filling limit as provided in 4.4.3.3(a). The level is computed on the basis of the liquid temperature being 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers. F.5.2.2 The percentage of container capacity that can be filled with liquid is computed by use of the formula shown in F.5.1.2, substituting the appropriate values as follows:
Vt =
L Gx F
where:
t = the liquid temperature [assumed to be 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers] L = the loading limit obtained from Table 4.4.2.1 for: (a) The specific gravity of the LP-Gas to be contained (b) The method of installation, aboveground or underground, and if aboveground, then: (1) For containers of 1200 gal (4.5 m3) water capacity or less (2) For containers of more than 1200-gal (4.5-m3) water capacity G = the specific gravity of the LP-Gas to be contained F = the correction factor (obtained from Table F.3.3, using G and 40°F (4°C) for aboveground containers or 50°F (10°C) for underground containers) Example: The maximum volume of LP-Gas with a specific gravity of 0.508 that can be in a 1000-gal (3.8-m3) water capacity aboveground container that is filled by use of a fixed maximum liquid level gauge is computed as follows: t is 40°F (4.4°C) for an aboveground container. L for 0.508 specific gravity, and an aboveground container of less than 1200-gal (4.5-m3) water capacity, from Table 4.4.2.1, is 42 percent. G is 0.508. F for 0.508 specific gravity at 40°F (4.4°C) from Table F.3.3 is 1.033. Thus,
V40 =
0.45 0.508 x 1.033 = 0.800 (80%) or 800 gal (3 m3)
F.5.2 Alternate Method of Filling Containers. F.5.2.1 Containers equipped with fixed maximum level gauges or with variable liquid level gauges when temperature determinations are not practical can be filled with eiThe VICTOR Propane Equipment Catalog
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
APPENDIX A
Liquified Petroleum Gas Code* (cont.)
APPENDIX A
154 APPENDIX A Table 3.2.2.2 Separation Distances Between Containers, Important Buildings, and Other Properties* Minimum Distances Mounded or Underground Containers a ft m 10 3 10 3 10 3 10 3 50 15 50 15 50 15 50 15 50 15 50 15 50 15
Water Capacity per Container gal <125d 125–250 251–500 501–2000 2001–30,000 30,001–70,000 70,001–90,000 90,001–120,000 120,001–200,000 200,001–1,000,000 >1,000,000
m3 <0.5d 0.5–1.0 1.0+–1.9 1.9+–7.6 7.6+–114 114+–265 265+–341 341+–454 454+–757 757+–3785 >3785
Aboveground Between Containers b Containers c ft m ft m 0e 0e 0 0 10 3 0 0 10 3 3 1 25 7.6 3 1 50 15 5 1.5 75 23 100 30 1/4 of sum of 125 38 diameters of 200 61 adjacent containers 300 91 400 122
a
See 3.2.2.2 Exception No. 2. See 3.2.2.2(g). c See 3.2.2.2(f). d See 3.2.2.2(a). e See 3.2.2.2(b), (c), and (d). b
Table 3.2.2.2(d) Separation Distance Between Container Pressure Relief Valve and Building Openings
Container Type Cylinder Cylinder ASME
Exchange orFilled on Site Exchange Filled on site Filled on site
Distance Horizontally from Relief Valve Discharge to Opening Below Discharge
Discharge from Relief Valve, Vent Discharge, and Filling Connection to Exterior Source of Ignition, Openings into Direct-Vent Appliances, Mechanical Ventilation Air Intakes
ft
m
ft
m
3 3
0.9 0.9
5 10
1.5 3.0
5
1.5
10
3.0
(f) Where underground multicontainer installations are made of individual containers having a water capacity of 125 gal (0.5 m3) or more, such containers shall be installed so as to allow access at their ends or sides to facilitate working with cranes or hoists. (g) In applying the distance between buildings and ASME containers of 125-gal (0.5-m3) or more water capacity, a minimum of 50 percent of this horizontal distance shall also apply to all portions of the building that project more than 5 ft (1.5 m) from the building wall and that are higher than the relief valve discharge outlet. This horizontal distance shall be measured from a point determined by projecting the outside edge of such overhanging structure vertically downward to grade or other level upon which the container is installed.
Exception No. 1: Not applicable to installations in which overhanging structure is 50 ft (15 m) or more above the relief valve discharge outlet. Exception No. 2: Where the distance from a 2001 to 30,000 gal container to a building are in accordance with 3.11.2 and 3.11.4.
3.2.2.3 Where storage containers having an aggregate water capacity of more than 4000 gal (15.1 m3) are located in heavily populated or congested areas, the siting provisions of 3.2.2.2 and Table 3.2.2.2 shall be permitted to be modified as indicated by the fire safety analysis described in 3.10.2.2. 3.2.2.4 Aboveground multicontainer installations comprised of containers having an individual water capacity of 12,000 gal (45 m3) or more and installed for use in a single location shall be limited to the number of containers in one group, with each group separated from the next group in accordance with the degree of fire protection provided in Table 3.2.2.4. Exception: Where the provisions of 3.11.3 and 3.11.4 are met the minimum separation distance between groups of ASME containers protected by hose stream only shall be one-half the distances in Table 3.2.2.4.
3.2.2.5 Underground or mounded containers shall be located outside of any buildings. Buildings shall not be constructed over any underground or mounded containers. Sides of adjacent containers shall be separated in accordance with Table 3.2.2.2 but shall not be separated less than 3 ft (1 m). Where underground or mounded containers are installed parallel with ends in line, the number of containers in one group shall not be limited. Where more than one row is installed, the adjacent ends of the tanks in each row shall be separated by not less than 10 ft (3 m). * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX A
155
Why is the fill so important? It is important that the first time a new propane tank is filled that it be filled to its maximum allowable liquid level with propane. This will help counteract the possible depletion of the odorant added to propane as a warning device in the event of a gas leak. Why? This puts the maximum amount of gas in the tank, which in turn puts the highest volume of ethyl mercaptan in the tank at a time when the odorant is most likely to be absorbed, absorbed or broken down by oxidation in the tank. If the odor produced by ethyl mercaptan is allowed to fade too much, its effectiveness as a warning device is diminished or may even be eliminated.
The propane dealer should advise and warn the customer: • About the presence of the odorant in propane gas and give the customer a scratch-and-sniff pamphlet to allow those using the propane gas to become familiar with the smell of the odorant. • That the odorant can fade or become less intense. Competing odors and a person’s inability to smell can also mask or cover up propane odor. • Gas detectors may provide an extra measure of safety. • They should not rely only upon the smell of propane for detection of propane gas. Failure to properly advise the users of propane about its properties and those of ethyl mercaptan could lead to a severe fire or explosion hazard, resulting in death or bodily injury.
Why is putting methanol in a tank so important? Freeze-ups!!! An LP-gas regulator can double for a fairly effective small refrigerator. This is because the high-pressure gas, coming into the regulator, expands as it goes through the orifice. This expansion of gas creates refrigeration. Therefore, if there is moisture in the gas, small droplets may freeze as they are attempting to pass through the cold orifice. If the flow of gas is large enough and there is enough moisture in the fuel, the orifice of the regulator could well be blocked by ice, stopping the flow of gas. Freeze-ups can occur even though outside temperatures are above freezing. How does moisture get in the tank? ASME tanks are hydrostatically tested during fabrication, thereby introducing moisture to the tank. Vacuum pre-purging of tanks should eliminate most of this moisture and air containing moisture from the tank. That is why it is important that air (which will contain moisture) not be allowed into the tank when the vacuum is neutralized when first filling a vacuum pre-purged tank.
The VICTOR Propane Equipment Catalog
The easiest way to cure this type of freeze-up is to keep as much moisture as possible from your fuel. Adding genuine absolute anhydrous methanol (99.85 pure) to your tanks when you first fill them is extra insurance to prevent freeze-ups from any moisture that may still be in the new tank. Methanol will lower the freezing point of water sufficiently to prevent freezing. When mounting the regulator, be sure the regulator outlet is higher than the service valve outlet. If pigtails are “looped,” be sure the loop is upward, preventing moisture from collecting and freezing at the bottom of the loop. Many times regulators are blamed for freeze-ups when ice frozen in the pigtails is the cause. Use larger pigtails (3/8” OD hogtails have more than three times the cross-sectional area of the standard 1/4” pigtail). Two-stage regulation helps prevent freeze-ups.
Warning and notice about the proper installation of propane tanks designed for use underground When a tank is designed for use in the underground storage of propane gas, a licensed propane dealer or installer must install it. The party installing the tank must inspect the tank and ensure that at the time of installation the external coating applied to the tank by the manufacturer remains continuous and intact. Failure to install the propane tank with an intact and continuous external coating voids all warranties (but not disclaimers) of the manufacturer. It is the responsibility of the purchaser or installer 1) determine whether additional protection should be used and 2) determine mat the additional protection is compatible with the coating applied by the manufacturer. To help ensure long-term protection of the underground tank, cathodic protection; should be used and may be required by governing authorities having jurisdiction over the installation of underground propane tanks at the installation site. This tank is sold subject to and limited by the terms and conditions of sale, including, but not limited to, the manufacturer’s warranty. Periodic inspections of tanks installed underground are recommended and may be required by the jurisdiction where installed. The container and valves of propane tanks to be buried underground should also be carefully checked for leaks immediately prior to installation in the ground. The licensed propane dealer or installer should make sure they follow all applicable federal, state or local regulatory requirements for protective coatings when they install a propane tank underground. The purchaser and installer are responsible for compliance with such federal, state and local regulations.
APPENDIX A
Important Safety Information for the Dealer and Your Service and Installation Personnel
APPENDIX A
156 APPENDIX A Purging LP-Gas Containers Up to 2,000 Water Gallon Capacity — ASME & DOT Containers, Including Motor Fuel Containers Purging and moisture removal All new containers (and in some cases used containers) may contain water, air, or other contaminants, and it is essential that these be removed before filling the container and placing it into service. Water vapor present in the gas vapor may cause regulator freeze-up at the inlet orifice and interrupt the gas service. Also, it may have an effect on the ability of the odorant to meet the present standards, as water can cause oxidation (rusting) on the inside of the container and result in “odorant fade.” Air in the container will cause abnormally high pressure, with the result that the pressure relief valve may open. Air in the system is also likely to cause pilot flames to go out and result in a service call. Additionally, air in the container carries moisture, which can cause service problems. If a container is suspected of being depressurized or open to the atmosphere for a period of time, it must be re-purged as if it were a new container. To purge a container, the following steps should be taken: 1. Purging of containers should be performed in an approved area (see NFPA #58). 2. Determine if the container pressure is zero. Should the container contain only air pressure, the air may be vented directly to the atmosphere through the service valve. 3. If free water is present in the container, it should be drained. 4. Pressurize the container to approximately 15 PSIG with LP-gas vapor. Never purge with liquid LP-gas; to do so will cause the moisture vapor to chill and remain in the container. 5. Fully open the container service valve and vent to a safe atmosphere. 6. Repeat fourth and fifth steps for a total of five purgings. 7. The usual five purge pressurization methods requires the venting of about 15-18 gallons of LP-gas per 1,000 gallons of container capacity. 8. Add the suggested amount of methanol (see chart below) and close valve. Methanol must be used in an approved and safe manner. Refer to the methanol MSDS for proper handling and warnings.
11. Once filled, all fittings and tank openings should be checked for leaks using an approved leak detecting solution. 12. The container is now ready to be placed in service. Methanol Injection Chart — Suggested Amounts 1 pint of methanol per 100 gallons of container capacity 100# I. C. C. or D. 0. T. cylinder add 1/8 pint or 2 fluid ounces 100 gallon container add 1 pint 250 gallon container add 2.5 pints 500 gallon container add 5 pints 1,000 gallon container add 10 pints 2,000 gallon container add 20 pints
Alternate Purge Method Utilizing a Compressor An LP-Gas compressor can be used to evacuate air in a container to about 26" of mercury vacuum (2 PSI absolute pressure) when discharging to atmosphere. Hose suitable for vacuum service would be used and all unused valves must be closed. Protective caps on both liquid fill and vapor equalization valves must be screwed on tightly to prevent air from entering the container when vacuum is applied. When pressure has been reduced to 26" of mercury vacuum LP gas vapor can be introduced until the container has reached atmospheric pressure. Add methanol as suggested and the container is then ready to be filled with liquid LP-gas. This method effectively removes water vapor after the water is drained and reduces air in the container to about 10 of the volume at atmospheric pressure. No LP-gas is released to he atmosphere with this process. Evacuation time with the 36 CFM compressor is approximately 15 minutes per 1,000 gallons of tank capacity. A CFM comporssor would take approximately 30 minutes per 1,000 gallons of tank capacity.
Addendum A. See NFPA-58 for more information on purging. B. Consult Material Safety Data Sheet (MSDS - Methanol) for additional information on care and handling of methanol. C. Consult NPGA Safety Bulletin on “Static Electricity”
9. Repressurize the container with odorized LP-gas vapor to 15 PSIG. 10. The container is now ready to be filled with LP-gas.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX A
157
What is Corrosion? Corrosion of a steel tank is an electrical and chemical deterioration of the metal. It is sometimes called “electrolysis”. It causes pits which lead to holes on one place and not another.
What is Cathodic Protection? Cathodic protection is a procedure used to protect an object from corrosion by making it a cathode. To make a tank a cathode, you have to attach an anode to it. Both have to be in an electrolyte such as earth or water. To protect a propane tank, you would attach at least one anode consisting of a bar of magnesium metal packed inside a cloth bag containing conductive earth backfill with a wire that is attached to the magnesium and the tank. Usually, 17 lbs. of magnesium and 28 Ibs. of earth backfill are used. The magnesium is a source of electrons for the iron atoms and it is from where d.c. current originates. As long as enough electrons flow from the magnesium through the wire and the connections on the tank, the tank will not corrode.
Why You Should Use Cathodic Protection When Installing an Underground Propane Tank First, what makes soil corrosive? Soil contains water and dissolved minerals responsible for damaging underground tanks. If you answer any of the following questions yes, then the tank will be corroded by the soil. Will it ever rain or snow there? Will the property owner plant grass, flowers, shrubs or trees over or near the tank? Will the grass, flowers, shrubs or trees be fertilized? Will ground moisture condense on the outside of the tank? Will water condense out of thin air on the surface of a cold container? Will the tank be near a sidewalk or down gradient from a driveway? Will the property owner ever throw salt or calcium chloride on the pavement to melt snow and ice? Will the tank ever be located near or downhill from livestock where salt and urea from animal waste will leach into the earth? Does the irrigation water contain salt or alkali salts? If a tank is set in a hole blasted from solid rock, does the rock contain pyrites, graphite or acidic rock that will be fractured and exposed to the oxidizing effect of air and water? If the tank is backfilled with sand or gravel from a sand or gravel company, will the sand contain minerals mined from river deposits not representative of the site in which the tank is to be buried? Will the tank be downhill from a septic tank leach field? Will the soil contain gypsum? Will the tank be set in shale or clay? Will groundwater be present? Will the tank be set on undisturbed earth and backfilled with loose backfill?
The VICTOR Propane Equipment Catalog
Second, let’s consider coatings, the traditional way of preparing underground propane tanks for installation. All steel objects are painted to keep them from rusting. The paint is a waterproof barrier between the steel surface and moisture in the air. Similarly, underground tanks need a waterproof coating to protect them from corrosive groundwater. Ordinary paint coatings do not hold up under constant contact with mineralized moisture in the earth. Therefore, specialized coatings are needed to withstand the corrosive environment underground and provide a barrier between the steel surface and air, water and even electricity without deteriorating over time. The first line of defense against corrosion on an underground tank is good coating. Paint and coating companies make a variety of coatings for a vast array of applications. It is important to apply those that will hold up over time to constant attack by water, oxygen, carbon dioxide, mild acids, mechanical abrasion from rocks, earth movements, roots, bacteria and other biological organisms as they feed on organic compounds in them. They must be applied correctly or they will not adhere to the steel surface. Quality Steel applies a tough chemical and water resistant coating at the factory — a hard, baked on polyurethane finish. This factory applied coating is designed to be the final coating for the tank prior to its burial in the ground, provided the tank has an intact and continuous external coating at the time of burial. It is the installer’s responsibility to thoroughly inspect the tank to determine whether the factory applied protective coating is intact and continuous. If the coating is not found to be intact and continuous, then additional protection that is compatible with the manufacturer’s coating must be applied in a way to obtain this important result prior to burial. Coatings alone may not protect a buried tank against corrosion. After inspection and touchup the tanks can still get scratched, scraped and gouged during handling, setting, backfilling and settling. As a result the coating can have small imperfections here and there. Corrosion pitting rates are greater at these flaws, scratches and gaps in the coating than they are on completely bare tanks. Therefore, cathodic protection with anodes is needed to protect the steel wherever it is exposed.
So, what can you do to provide cathodic protection for the underground propane tank? Anodes of magnesium are used to make the propane tank a cathode, thus improving its protection against possible corrosion. Magnesium anodes come in all shapes and sizes. The magnesium in a packaged anode can weigh from 1 to 50 Ibs. The most commonly used anode in the United States is a 17 Ib. anode. With 28 Ibs. of powdered backfill packed around the magnesium, a packaged 17 lbs.anode weighs about 45 Ibs.
APPENDIX A
Why You Should Use Cathodic Protection When Installing an Underground Propane Tank
APPENDIX A
158 APPENDIX A Why You Should Use Cathodic Protection When Installing an Underground Propane Tank (cont.) Tests on underground propane tanks have shown that smaller anodes can be effective at controlling corrosion on a well coated tank. Small anodes are used when the surface area or object to be protected is small. They cost less but cost the same as a large anode to install. However, it is important to remember that the life of a small anode is shorter than for a larger one. One of the more common questions asked is, “How long will an anode last?” Design engineers prefer to use larger anodes (and in greater numbers) because they last longer. The conditions and environment in which tanks and anodes are buried are so varied (as well as change with time) so that there is no definitive answer. Finally, however, when an anode is 85 consumed, it becomes too small to be effective. Because soil conditions change with time, one can hope for the best but plan for the worst.
How do you install the anode? This is a very important question, for if the anode is not properly installed, it will not work. Schmoldt recommends the following: Install one 17 Ib. magnesium anode on a 500 gal. tank and two on a 1,000 gal. tank. The reason for the latter is to ensure that enough cathodic protection current is available for many years. Bury the anode at the end of the excavation where the earth is the wettest and the most conductive to the anode current. If water is available, pour 5 gal. on the anode to “jump start” the flow of current. Otherwise, the dry backfill will have to absorb moisture from the soil before current will flow. Roll out the anode wire to either the flat plate fitting on top of the tank or to the lifting ear. Wrap the wire around the fitting or ear so that the connection can not be pulled off should someone trip on the
wire. Leave slack in the wire so that it is not pulled apart when the excavation is backfilled. The wire can be attached to the tank by a thermite weld or with a nut and bolt. Whether you use a thermite weld or nut and bolt, remove 1” insulation on the copper wire and file off any paint or coating at the connection so that the metal wire is making contact to the tank for the weld or connection. If you use a thermite weld, the weld will not ignite the propane in the tank, but it could ignite propane in sufficient concentration in the excavation around the tank. Propane is heavier than air and will collect at your feet. If you smell propane, do not make the connection with the weld.
So, how do you know a tank is protected? It doesn’t take long to check, and a check should be made at least annually. If the voltage of steel is -0.85 volts or greater, it is protected. It takes a voltmeter and a copper sulfate electrode to take the reading. It can be taken by your service person with a basic understanding of cathodic protection. If the reading is >-0.85 volts, you can assume that the tank is protected at the location where the reading was taken on the date it was taken. If the reading is <-0.85 volts, the anode installed on the tank either has been consumed, or the tank is connected to the house utilities without dielectric union, or the wire has been disconnected. Occasionally, there is a problem with the testing equipment or contact to the tank. The voltmeter’s contact with the tank can be made on any metal connected to the tank, including the gauging device, the regulator, the pressure relief valve or other fittings. The dome is not a good contact point. It is recommended that you take at least four readings around the tank.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX A
159
Figure 1*
Note 2: If the cylinder is filled on site from a bulk truck, the filling connection and vent valve must be at least 10 ft from any exterior source of ignition, openings into diNote 1: 5-ft minimum from relief valve in any direction away from any exterior source of ignition, openings into di- rect-vent appliances, or mechanical ventilation air inrect-vent appliances, or mechanical ventilation air intakes. takes. Refer to 3.2.2.2(d). Refer to 3.2.2.2(b). For SI units: 1 ft = 0.3048 m
Aboveground ASME containers (This figure for illustrative purposes only; local code shall govern) Figure 2*
For SI units: 1 ft = 0.3048 m Note 1: Regardless of its size, any ASME container filled on site must be located so that the filling connection and fixed maximum liquid level gauge are at least 10 ft from any external source of ignition (e.g., open flame, window A/C, compressor), intake to direct-vented gas appliance, or intake to a mechanical ventilation system. Refer to 3.2.2.2(d). The VICTOR Propane Equipment Catalog
Note 2: Refer to 3.2.2.2(c) Note 3: This distance may be reduced to no less than 10 ft for a single container of 1200 gal (4.5 m 3 ) water capacity or less, provided such container is at least 25 ft from any other LP-Gas container of more than 125 gal (0.5 m 3 ) water capacity.Refer to 3.2.2.2(e).
APPENDIX A
Cylinders (This figure for illustrative purposes only; local code shall govern)
APPENDIX A
160 APPENDIX A Underground ASME containers (This figure for illustrative purposes only; local code shall govern) Figure 3*
For SI units: 1 ft = 0.3048 m
Note 1: The relief valve, filling connection, and liquid fixed maximum level gauge vent connection at the container must be at least 10 ft from any exterior source of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 3.2.2.2(f). Note 2: No part of an underground container shall be less than 10 ft from an important building or line of adjoining property that may be built upon. Refer to 3.2.2.2(f).
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX B Propane 2488 1.50
Butane 3280 2.01
Btu per cubic foot = Specific gravity = Pressure at orifice, inches water column = 11 11 Orifice coefficient = 0.9 0.9 For altitudes above 2000 ft, first select the equivalent orifice size at sea level from Table F.4. Table F.2 LP-Gases (Btu per hour at sea level) Orifice or Drill Size 0.008 0.009 0.010 0.011 0.012 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52
Propane 519 656 812 981 1169 1480 1708 2080 2629 3249 3581 4119 4678 5081 5495 6375 6934 7813 8320 8848 9955 10535 11125 11735 12367 13008 13660 14333 15026 17572 21939 24630 28769 32805
Orifice or Drill Size 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18
Propane 36531 39842 43361 46983 50088 53296 54641 60229 64369 71095 74924 78029 80513 83721 87860 92207 98312 100175 103797 109385 117043 134119 150366 160301 168580 175617 181619 187828 192796 200350 205525 210699 223945 233466
Table F.3 Multipliers for Utility Gases of Another Specific Gravity* Specific Gravity
Specific Multiplier Gravity Multiplier
0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90
1.155 1.095 1.045 1.000 0.961 0.926 0.894 0.866 0.840 0.817
0.95 1.00 1.05 1.10 1.15 1.20 1.25 1.30 1.35 1.40
0.795 0.775 0.756 0.739 0.722 0.707 0.693 0.679 0.667 0.655
* This section is an excerpt from the NFPA 54 National Fuel Gas Code — 1999 Edition
Approximate Properties LP-Gases* Commercial Propane Vapor pressure in psi (absolute pressure at) 70°f 100°f 105°f 130°f
145 218 233 315
Specific gravity of liquid at 0.504 60°f Initial boiling point at 14.7 psia, °f –44 Weight per gallon of liquid at 60°f, lb 4.20 Specific heat of liquid, btu/lb at 60°f .630 Cubic feet of vapor per gallon at 60°f 36.38 Cubic feet of vapor per pound at 60°f 8.66 Specific gravity of vapor (air = 1) at 60°f 1.50 Ignition temperature in air, °f 920–1,120 Maximum flame temperature in air, °f 3,595 Limits of flammability in air, percent of vapor in air–gas mixture: lower upper
2.15 9.60
Latent heat of vaporization at boiling point btu per pound 184 btu per gallon 773 Total heating values after vaporization btu per cubic foot btu per pound btu per gallon
2,488 21,548 91,502
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
The VICTOR Propane Equipment Catalog
APPENDIX B
Table F.2 LP-Gases* (Btu per hour at sea level)
161
APPENDIX B
162 APPENDIX B Table F.1 Utility (or Natural Gas Specific Gravity .60) Gases* (cubic feet per hour at sea level) Orifice or Drill Size
Pressure at Orifice 3/4 Inches Water Column
Orifice or Drill Size
Pressure at Orifice 3/4 Inches Water Column
3.5
4
7
3.5
4
7
80 79 78 77 76
0.52 0.59 0.76 0.95 1.13
0.55 0.64 0.78 0.99 1.21
0.73 0.84 1.04 1.31 1.61
35 34 33 32 31
34.95 35.05 36.08 38.30 40.85
36.86 37.50 38.79 40.94 43.83
48.78 49.75 51.46 54.26 58.01
75 74 73 72 71
1.25 1.44 1.63 1.77 1.97
1.34 1.55 1.76 1.90 2.06
1.79 2.05 2.32 2.52 2.73
30 29 28 27 26
46.87 52.33 55.92 58.83 61.27
50.39 56.19 59.50 63.17 65.86
66.72 74.45 79.50 83.59 87.24
70 69 68 67 66
2.22 2.43 2.72 2.91 3.09
2.39 2.61 2.93 3.12 3.32
3.16 3.47 3.88 4.13 4.39
25 24 23 22 21
63.58 65.67 67.07 70.08 71.83
68.22 70.58 72.20 75.21 77.14
90.36 93.47 94.55 99.60 102.29
65 64 63 62 61
3.39 3.68 3.92 4.08 4.34
3.72 4.14 4.19 4.39 4.66
4.84 5.23 5.55 5.81 6.15
20 19 18 17 16
73.68 77.98 81.57 84.82 88.77
79.08 83.69 87.56 91.10 95.40
104.75 110.67 116.03 120.33 126.78
60 59 58 57 56
4.55 4.76 5.03 5.23 6.13
4.89 5.11 5.39 5.63 6.58
6.47 6.78 7.13 7.44 8.73
15 14 13 12 11
92.02 94.40 97.11 101.41 103.62
98.84 100.78 104.32 108.52 111.31
131.07 133.22 138.60 143.97 147.20
55 54 53 52 51
7.68 8.59 10.04 11.46 12.77
8.22 9.23 10.80 12.31 13.69
10.85 12.25 14.29 16.34 18.16
10 9 8 7 6
106.16 109.07 112.20 114.40 117.88
114.21 117.11 120.65 123.01 126.78
151.50 154.71 160.08 163.31 167.51
50 49 48 47 46
13.92 15.20 16.36 17.52 18.57
14.94 16.28 17.62 18.80 19.98
19.77 21.60 23.31 24.93 26.43
5 4 3 2 1
119.97 123.93 128.79 138.76 147.26
128.93 133.22 137.52 148.61 158.25
170.82 176.18 182.64 197.66 209.48
45 44 43 42 41
19.15 21.01 22.39 24.95 25.98
20.52 22.57 24.18 26.50 28.15
27.18 29.87 32.02 35.24 37.17
40 39 38 37 36
27.03 28.20 29.25 30.63 32.14
29.23 30.20 31.38 32.99 34.59
38.79 39.97 41.58 43.62 45.77
For SI units, 1 Btu/hr = 0.293 W; 1 ft3 = 0.028 m3; 1 ft = 0.305 m; 1 in. water column = 249 pa. Notes: 1. Specific Gravity = 0.60; orifice coefficient = 0.90. 2. For utility gases of another specific gravity, select multiplier from Table F.3. For altitudes above 2000 ft, first select the equivalent orifice size at sea level from Table F.4.
* This section is an excerpt from the NFPA 54 National Fuel Gas Code
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX C
163
This appendix is not a part of the requirements of this NFPA document but is included for informational purposes only. F.1 Scope. F.1.1 Application. This appendix explains the basis for Table4.4.2.1, includes the LP-Gas liquid volume temperature correction table, Table F.3.3, and describes its use. It also explains the methods of making liquid volume computations to determine the maximum permissible LP-Gas content of containers in accordance with Tables 4.4.2.2(a), (b), and (c). F.2 Basis for Determination of LP-Gas Container Capacity. The basis for determination of the maximum permitted filling limits shown in Table 4.4.2.1 is the maximum safe quantity that will assure that the container will not become liquid full when the liquid is at the highest anticipated temperature. F.2.1 For portable containers built to DOT specifications and other aboveground containers with water capacities of 1200 gal (4.5 m3) or less, this temperature is assumed to be 130°F (54°C). F.2.2 For other aboveground uninsulated containers with water capacities in excess of 1200 gal (4.5 m3), including those built to DOT portable or cargo tank specifications, this temperature is assumed to be 115°F (46°C). F.2.3 For all containers installed under ground, this temperature is assumed to be 105°F (41°C). F.3 Liquid Volume Correction Table. Correction of observed volume to standard temperature condition (60°F and equilibrium pressure). F.3.1 The volume of a given quantity of LP-Gas liquid in a container is directly related to its temperature, expanding as temperature increases and contracting as temperature decreases. Standard conditions, often used for weights and measures purposes and, in some cases, to comply with safety regulations, specify correction of the observed volume to what it would be at 60°F (16°C).
F.3.2 To correct the observed volume to 60°F (16°C), the specific gravity of LP-Gas at 60°F (16°C) in relation to water at 60°F (16°C) (usually referred to as “60°/60°F”) and its average temperature must be known. The specific gravity normally appears on the shipping papers. The average liquid temperature can be obtained as follows: (1) Insert a thermometer in a thermometer well in the container into which the liquid has been transferred, and read the temperature after the completion of the transfer [see F.3.2(c) for proper use of a thermometer]. (2) If the container is not equipped with a well, but is essentially empty of liquid prior to loading, the temperature of the liquid in the container from which liquid is being withdrawn can be used. Otherwise, a thermometer can be inserted in a thermometer well or other temperature-sensing device installed in the loading line at a point close to the container being loaded. Read temperatures at intervals during transfer and averaging. [See F.3.2(c).] (3) A suitable liquid should be used in thermometer wells to obtain an efficient heat transfer from the LPGas liquid in the container to the thermometer bulb. The liquid used should be noncorrosive and should not freeze at the tem-peratures to which it will be subjected. Water should not be used. F.3.3 The volume observed or measured is corrected to 60....F (16....C) by use of Table F.3.3. The column headings, across the top of the tabulation, list the range of specific gravities for the LP-Gases. Specific gravities are shown from 0.500 to 0.590 by 0.010 increments, except that special columns are inserted for chemically pure propane, isobutane, and normal butane. To obtain a correction factor, follow down the column for the specific gravity of the particular LP-Gas to the factor corresponding with the liquid temperature. Interpolation between the specific gravities and temperatures shown can be used if necessary.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas
The VICTOR Propane Equipment Catalog
APPENDIX C
Appendix F Liquid Volume Tables, Computations, and Graphs*
APPENDIX C
164 APPENDIX C Liquid Volume Correction Factors* Specific Gravities at 60°F/60°F OBSERVED PROPANE TEMPERATURE, 0.5079 DEGREES FAHRENHEIT –50 1.155 –45 1.148 –40 1.142 –35 1.135 –30 1.129 –25 1.122 –20 1.115 –15 1.109 –10 1.102 –5 1.094 0 1.088 2 1.086 4 1.083 6 1.080 8 1.078 10 1.075 12 1.072 14 1.070
OBSERVED PROPANE TEMPERATURE, 0.5079 DEGREES FAHRENHEIT 16 1.067 18 1.065 20 1.062 22 1.059 24 1.056 26 1.053 28 1.050 30 1.047 32 1.044 34 1.041 36 1.038 38 1.035 40 1.032 42 1.029 44 1.026 42 1.029 44 1.026 46 1.022
OBSERVED PROPANE TEMPERATURE, 0.5079 DEGREES FAHRENHEIT 48 1.019 50 1.016 52 1.013 54 1.010 56 1.007 58 1.003 60 1.000 62 0.997 64 0.993 66 0.990 68 0.986 70 0.983 72 0.980 74 0.976 76 0.973 78 0.970 80 0.967 82 0.963
OBSERVED PROPANE TEMPERATURE, 0.5079 DEGREES FAHRENHEIT 84 0.959 86 0.956 88 0.952 90 0.949 92 0.945 94 0.941 96 0.938 98 0.934 100 0.930 105 0.920 110 0.911 115 0.902 120 0.892 125 0.881 130 0.871 135 0.861 140 0.850
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX D
165
3.7.2 Electrical Equipment.
3.6.3.1 Direct-fired vaporizers shall comply with 2.5.5.2 and shall be installed as follows.
3.7.2.1 Electrical equipment and wiring shall be of a type specified by, and installed in accordance with, NFPA 70, National Electrical Code®, for ordinary locations.
3.6.3.2 Where a direct-fired vaporizer is installed in a separate structure, the separate structure shall be constructed in accordance with Chapter 7. 3.6.3.3 The housing for direct-fired vaporizers shall not have any drains to a sewer or a sump pit that is shared with any other structure or to a sewer. Pressure relief valve discharges on direct-fired vaporizers shall be piped to a point outside the structure or building. 3.6.3.4 Direct-fired vaporizers shall be connected to the liquid space or to the liquid or vapor space of the container. A manually operated shutoff valve shall be installed in each connection of the container supplying the vaporizer. 3.6.3.5 Direct-fired vaporizers of any capacity shall be located in accordance with Table 3.6.3.5.
Exception: Fixed electrical equipment in classified areas shall comply with 3.7.2.2. 3.7.2.2* Fixed electrical equipment and wiring installed within classified areas specified in Table 3.7.2.2 shall comply with Table 3.7.2.2 and shall be installed in accordance with NFPA 70, National Electrical Code. The provision shall apply to vehicle fuel operations. (See Figure 3.7.2.2.)
Exception: This provision shall not apply to fixed electrical equipment at residential or commercial installations of LP-Gas systems or to systems covered by Section 3.8.
FIGURE 3.7.2.2 Extent of electrically classified area. (See Table 3.7.2.2.)
Table 3.6.3.5 Minimum Separation Distances Between Direct-Fired Vaporizers and Exposures EXPOSURE Container
MINIMUM DISTANCE REQUIRED FT M 10 3.0
Container shutoff valves
15
4.6
Point of transfer
15
4.6
Nearest important buildings or group of buildings or line of adjoining property that can be built
25
7.6
Nearest Chapter 7 building or room housing gas–air mixer
10
3.0
Cabinet housing gas–air mixer outdoors
0
0
Note: Do not apply distances to the building in which a direct-fired vaporizer is installed.
3.6.6. Installation of Waterbath Vaporizers. Waterbath vaporizers shall comply with 2.5.5.3 and shall be installed as follows: 3.6.6.1 If a waterbath vaporizer is electrically heated and all electrical equipment is suitable for Class 1, Group D locations, the unit shall be treated as indirect-fired and shall be installed in accordance with 3.6.2. 3.6.6.2 All other waterbath vaporizers shall be treated as direct-fired vaporizers and shall be installed in accordance with 3.6.3. 3.6.7 Installation of Electric Vaporizers. Electric vaporizers, whether direct immersion or indirect immersion, shall be treated as indirect-fired and shall be installed in accordance with 3.6.2. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
The VICTOR Propane Equipment Catalog
3.7.2.3 Fired vaporizers, calorimeters with open flames, and other areas where open flames are present either intermittently or constantly shall not be considered electrically classified areas.
APPENDIX D
3.6.3 Installation of Direct-Fired Vaporizers.
APPENDIX E
166 APPENDIX E D. Suggested Method for Checking for Leakage* This appendix is not a part of the requirements of this code but is included for informational purposes only. D.1 Use of Lights. Artificial illumination used in connection with a search for gas leakage should be restricted to battery-operated flashlights (preferably of the safety type) or approved safety lamps. In searching for leaks, electric switches should not be operated. If electric lights are already turned on, they should not be turned off. D.2 Testing for Leakage Using the Gas Meter. Immediately prior to the test, it should be determined that the meter is in operating condition and has not been bypassed. Checking for leakage can be done by carefully watching the test dial of the meter to determine whether gas is passing through the meter. To assist in observing any movement of the test hand, wet a small piece of paper and paste its edge directly over the centerline of the hand as soon as the gas is turned on. This observation should be made with the test hand on the upstroke. Table D.2 can be used for determining the length of observation time. Table D.2 Test Observation Times for Various Meter Dials DIAL STYLES (FT3)
TEST TIME (MINUTES)
1/4 1/2 1 2 5 10
5 5 7 10 20 30
For SI units, 1 ft3 = 0.028 m3.
In case careful observation of the test hand for a sufficient length of time reveals no movement, the piping should be purged and a small gas burner turned on and lighted, and the hand of the test dial again observed. If the dial hand moves (as it should), it will show that the meter is operating properly. If the test hand does not move or register flow of gas through the meter to the small burner, the meter is defective and the gas should be shut off and the serving gas supplier notified. D.3 Testing for Leakage Not Using a Meter. This test can be done by one of the following methods: (a) For Any Gas System. To an appropriate checkpoint, attach a manometer or pressure gauge between the inlet to the piping system and the first regulator in the piping system, and momentarily turn on the gas supply and observe the gauging device for pressure drop with the gas supply shut off. No discernible drop in pressure should occur during a period of 3 minutes.
(b) For Gas Systems Using Undiluted Liquefied Petroleum Gas. System Preparation for Propane. A leak check performed on an LP-Gas system being placed back in service should include all regulators, including appliance regulators, and control valves in the system. Accordingly, each individual equipment shutoff valve should be supplying pressure to its appliance for the leak check. This check will prove the integrity of the 100 percent pilot shutoff of each gas valve so equipped, so the manual gas cock of each gas valve incorporating a 100 percent pilot shutoff should be in the on position. Pilots not incorporating a 100 percent pilot shutoff valve and all manual gas valves not incorporating safety shutoff systems are to be placed in the off position prior to leak checking, by using one of the following methods: (1) By inserting a pressure gauge between the container gas shutoff valve and the first regulator in the system, admitting full container pressure to the system and then closing the container shutoff valve. Enough gas should then be released from the system to lower the pressure gauge reading by 10 psi (69 kPa). The system should then be allowed to stand for 3 minutes without showing an increase or a decrease in the pressure gauge reading. (2) For systems serving appliances that receive gas at pressures of 1/2 psi (3.5 kPa) or less, by inserting a water manometer or pressure gauge into the system downstream of the final system regulator, pressurizing the system with either fuel gas or air to a test pressure of 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column, and observing the device for a pressure change. If fuel gas is used as a pressure source, it is necessary to pressurize the system to full operating pressure, close the container service valve, and then release enough gas from the system through a range burner valve or other suitable means to drop the system pressure to 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column. This ensures that all regulators in the system are unlocked and that a leak anywhere in the system is communicated to the gauging device. The gauging device should indicate no loss or gain of pressure for a period of 3 minutes.
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
APPENDIX E
167
3.2.15.3 Metallic pipe joints shall be permitted to be threaded, flanged, welded, or brazed using pipe and fittings that comply with 2.4.2 and 2.4.4 as follows. (a) Metallic threaded and welded pipe joints shall be in accordance with Table 3.2.15.3(a).
Table 3.2.15.3(a) Types of Metallic Pipe Joints in LP-Gas Service SERVICE Liquid
SCHEDULE 40 Welded
SCHEDULE 80 Threaded or welded
Vapor, £125 psig (£0.9 MPag)
Threaded or welded
Threaded or welded
Vapor, >125 psig (>0.9 MPag)
Welded welded
Threaded or
(b) Fittings and flanges shall be designed for a working pressure equal to or greater than the required working pressure of the service for which they are used. (c) Brazed joints shall be made with a brazing material having a melting point exceeding 1000°F (538°C). (d) Gaskets used to retain LP-Gas in flanged connections in piping shall be resistant to the action of LP-Gas. They shall be made of metal or material confined in metal having a melting point over 1500°F (816°C) or shall be protected against fire exposure. When a flange is opened, the gasket shall be replaced. Exception No. 1: Aluminum O-rings and spiral wound metal gaskets shall be permitted. Exception No. 2: Nonmetallic gaskets used in insulating fittings shall be permitted.
3.2.15.4 Metallic tubing joints shall be flared or brazed using tubing and fittings in accordance with 2.4.3 and 2.4.4. 3.2.15.5 Piping in systems shall be run as directly as is practical from one point to another, with as few fittings as practical. Where condensation of vapor can occur, piping shall be sloped back to the container or means shall be provided for revaporizing the condensate. 3.2.15.6 Piping systems including interconnecting of permanently installed containers shall compensate for expansion, contraction, jarring and vibration, and for settling. Using flexible connectors complying with 2.4.6 shall be permitted. The use of nonmetallic pipe, tubing, or hose for permanently interconnecting such containers shall be prohibited.
The VICTOR Propane Equipment Catalog
3.2.15.7 Aboveground piping shall be supported and protected against physical damage by vehicles. The portion of aboveground piping in contact with a support or a corrosion-causing substance shall be protected against corrosion. 3.2.15.8 Buried metallic pipe and tubing shall be installed underground with a minimum 18 in. (460 mm) of cover. The cover shall be permitted to be reduced to 12 in. (300 mm) if external damage to the pipe or tubing is not likely to result. If a minimum 12 in. (300 mm) of cover cannot be maintained, the piping shall be installed in conduit or shall be bridged (shielded). Where underground piping is beneath driveways, roads, or streets, possible damage by vehicles shall be taken into account. 3.2.15.9 Underground metallic piping shall be protected against corrosion as warranted by soil conditions (see 3.2.24). 3.2.15.10 LP-Gas piping shall not be used as a grounding electrode. 3.2.16 Polyethylene Pipe, Tubing, and Fittings. 3.2.16.1 Polyethylene pipe, tubing and fittings shall be installed outdoors underground only. 3.2.16.2 Polyethylene pipe and tubing shall be buried as follows: (1) With a minimum 18 in. (460 mm) of cover (2) With a minimum of 12 in. (300 mm) of cover if external damage to the pipe or tubing is not likely to result (3) If a minimum 12 in. (300 mm) of cover cannot be provided, with piping installed in conduit or bridged (shielded). 3.2.16.3 Assembled anodeless risers shall be used to terminate underground polyethylene piping systems above ground. The horizontal portion of risers shall be buried at least 12 in. (300mm) below grade and the casing material used for the risers shall be protected against corrosion in accordance with 3.2.24. 3.2.16.4 Either the aboveground portion of the riser casing shall be provided with a plastic sleeve inside the riser casing or the pipe or tubing shall be centered in the riser casing. 3.2.16.5 Factory-assembled risers shall be sealed and leak tested by the manufacturer.
APPENDIX E
D. Suggested Method for Checking for Leakage (cont.)
APPENDIX E
168 APPENDIX E D. Suggested Method for Checking for Leakage* (cont.) 3.2.16.6 Field-assembled risers shall be supplied only in kit form with all necessary hardware for installation. Fieldassembled risers shall comply with the following: (1) Be design certified (2) Be sealed and pressure tested by the installer (3) Be assembled and installed in accordance with the riser manufacturer’s instructions 3.2.16.7 The casing of the riser shall be constructed of one of the following materials: (1) ASTM A 53, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless, Schedule 40 steel pipe (2) ASTM A 513, Standard Specification for Electric-Resistance-Welded Carbon and Alloy Steel Mechanical Tubing, mechanical steel tubing with a minimum wall thickness of 0.073in. (1.9 mm) (3) A flexible metal tubing with a minimum crush strength of 1000 lb (453.6 kg) and a tensile strength of 300 lb (136 kg) including the transition connection as tested by the manufacturer 3.2.16.8* Polyethylene piping shall be installed so as to minimize thrust forces caused by contraction or expansion of the piping or by anticipated external or internal loading. The pipeline shall be designed and installed so that each joint will sustain these forces. 3.2.16.9 An electrically continuous corrosion-resistant tracer wire (minimum AWG 14) or tape shall be buried with the polyethylene pipe to facilitate locating. One end shall be brought aboveground at a building wall or riser. The wire or tape shall not be in direct contact with the polyethylene pipe. 3.2.16.10 Polyethylene piping that is installed in a vault or any other belowground enclosure shall be completely encased in gastight metal pipe and fittings that are protected from corrosion.
* This section is an excerpt from the NFPA 54 National Fuel Gas Code — 1999 Edition
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
LP PIPE & TUBING SIZING TABLES
169
PIPE 1 / 2” LENGTH, FT 0.622 30 40 50 60 70 80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1500 2000
1843 1577 1398 1267 1165 1084 1017 961 772 660 585 530 488 454 426 402 364 335 312 293 276 222 190
1 / 4” 0.824
1” 1.049
11 / 4 ” 1.38
11 / 2 ” 1.61
2” 2.067
3” 3.068
31 / 2 ” 3.548
4” 4.026
3854 3298 2923 2649 2437 2267 2127 2009 1613 1381 1224 1109 1020 949 890 841 762 701 652 612 578 464 397
7259 6213 5507 4989 4590 4270 4007 3785 3039 2601 2305 2089 1922 1788 1677 1584 1436 1321 1229 1153 1089 875 748
14904 12756 11306 10244 9424 8767 8226 7770 6240 5340 4733 4289 3945 3670 3444 3253 2948 2712 2523 2367 2236 1795 1537
22331 19113 16939 15348 14120 13136 12325 11642 9349 8002 7092 6426 5911 5499 5160 4874 4416 4063 3780 3546 3350 2690 2302
43008 121180 177425 247168 36809 103714 151853 211544 32623 91920 134585 187487 29559 83286 121943 169877 27194 76622 112186 156285 25299 71282 104368 145393 23737 66882 97925 136417 22422 63176 92499 128859 18005 50733 74280 103478 15410 43421 63574 88564 13658 38483 56345 78493 12375 34868 51052 71120 11385 32078 46967 65430 10591 29843 43694 60870 9938 28000 40997 57112 9387 26449 38725 53948 8505 23965 35088 48880 7825 22047 32280 44969 7279 20511 30031 41835 6830 19245 28177 39253 6452 18178 26616 37078 5181 14598 21373 29775 4434 12494 18293 25483
Note: Maximum undiluted propane capacities listed are based on a gauge pressure of 10 psi first stage setting and 1 psi pressure drop. Capacities in 1000 Btu/hr.
Pipe Sizing Between 2-psi Service Regulator and Line Pressure Regulator: Nominal Pipe Size, Schedule 40* PIPE 1 / 2” LENGTH, FT 0.622 10 20 30 40 50 60 70 80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1500 2000
2687 1847 1483 1269 1125 1019 938 872 819 773 621 531 471 427 393 365 343 324 293 270 251 236 222 179 153
3 / 4” 0.824
1” 1.049
11 / 4 ” 1.380
11 / 2 ” 1.610
2” 2.067
3” 3.068
31 / 2 ” 3.548
4” 4.026
5619 3862 3101 2654 2352 2131 1961 1824 1712 1617 1298 1111 985 892 821 764 717 677 613 564 525 493 465 374 320
10585 7275 5842 5000 4431 4015 3694 3436 3224 3046 2446 2093 1855 1681 1546 1439 1350 1275 1155 1063 989 928 876 704 602
21731 14936 11994 10265 9098 8243 7584 7055 6620 6253 5021 4298 3809 3451 3175 2954 2771 2618 2372 2182 2030 1905 1799 1445 1237
32560 22378 17971 15381 13632 12351 11363 10571 9918 9369 7524 6439 5707 5171 4757 4426 4152 3922 3554 3270 3042 2854 2696 2165 1853
62708 176687 258696 360385 43099 121436 177800 247690 34610 97517 142780 198904 29621 83462 122201 170236 26253 73971 108305 150877 23787 67023 98132 136706 21884 61660 90280 125767 20359 57363 83988 117002 19102 53822 78803 109779 18043 50840 74437 103697 14490 40826 59776 83272 12401 34942 51160 71270 10991 30968 45342 63166 9959 28060 41083 57233 9162 25814 37796 52653 8523 24015 35162 48984 7997 22533 32991 45960 7554 21284 31164 43413 6844 19285 28236 39336 6297 17742 25977 36188 5858 16506 24167 33666 5496 15487 22675 31588 5192 14629 21419 29838 4169 11747 17200 23961 3568 10054 14721 20507
Note: Maximum undiluted propane capacities listed are based on a 2-psig setting and a 1-psi pressure drop. Capacities in 1000 Btu/hr. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
The VICTOR Propane Equipment Catalog
LP PIPE & TUBING SIZING TABLES
Pipe Sizing Between First-Stage and Second-Stage Regulators: Nominal Pipe Size, Schedule 40*
LP PIPE & TUBING SIZING TABLES
170 LP PIPE & TUBING SIZING TABLES Pipe Sizing Between Second-Stage Regulator and Appliance:* Nominal Pipe Size, Schedule 40 PIPE 1 / 2” LENGTH, FT 0.622 10 20 30 40 50 60 80 100 125 150 200 250 300 350 400
291 200 161 137 122 110 94 84 74 67 58 51 46 43 40
1 / 4” 0.824
1” 1.049
11 / 4 ” 1.38
11 / 2 ” 1.61
2” 2.067
3” 3.068
31 / 2 ” 3.548
4” 4.026
608 418 336 287 255 231 198 175 155 141 120 107 97 89 83
1146 788 632 541 480 435 372 330 292 265 227 201 182 167 156
2353 1617 1299 1111 985 892 764 677 600 544 465 412 374 344 320
3525 2423 1946 1665 1476 1337 1144 1014 899 815 697 618 560 515 479
6789 4666 3747 3207 2842 2575 2204 1954 1731 1569 1343 1190 1078 992 923
19130 13148 10558 9036 8009 7256 6211 5504 4878 4420 3783 3353 3038 2795 2600
28008 19250 15458 13230 11726 10625 9093 8059 7143 6472 5539 4909 4448 4092 3807
39018 26817 21535 18431 16335 14801 12668 11227 9950 9016 7716 6839 6196 5701 5303
Note: Maximum undiluted propane capacities listed are based on 11-in w.c. setting and 0.5 in pressure drop. Capacities in Btu/hr. Source: NFPA 54, National Fuel Gas Code, 1999 edition, Table 9.26.
Pipe Sizing Between First-Stage and Second-Stage Regulators:* Nominal Pipe Size,Schedule 80 PIPE 1 / 2” LENGTH, FT 0.546 30 1309 40 1121 50 993 60 900 70 828 80 770 90 723 100 683 150 548 200 469 250 416 300 377 350 347 400 322 450 303 500 286 600 259 700 238 800 222 900 208 1000 196 1500 158 2000 135
3 / 4” 0.742 2927 2505 2221 2012 1851 1722 1616 1526 1226 1049 930 842 775 721 676 639 579 533 495 465 439 353 302
1” 0.957 5706 4884 4328 3922 3608 3357 3149 2975 2389 2045 1812 1642 1511 1405 1318 1245 1128 1038 966 906 856 687 588
11 / 4 ” 1.278 12185 10429 9243 8375 7705 7168 6725 6353 5105 4366 3870 3506 3226 3001 2816 2660 2410 2217 2062 1935 1828 1468 1256
11 / 2 ” 1.5 18548 15875 14069 12748 11728 10911 10237 9670 7765 6646 5890 5337 4910 4568 4286 4048 3668 3375 3139 2946 2782 2234 1912
2” 3” 31 / 2 ” 4” 1.939 2.9 3.364 3.826 36368 104539 154295 216246 31127 89472 132057 185079 27587 79297 117039 164032 24996 71849 106046 148625 22996 66100 97561 136733 21393 61494 90762 127204 20073 57697 85159 119351 18960 54501 80440 112738 15236 43766 64596 90533 13031 37458 55286 77484 11549 33198 48999 68673 10465 30080 44397 62223 9627 27673 40844 57244 8956 25745 37998 53255 8403 24155 35652 49967 7938 22817 33677 47199 7192 20674 30514 42765 6617 19020 28072 39344 6156 17694 26116 36602 5776 16602 24504 34342 5456 15682 23146 32439 4381 12593 18587 26050 3750 10778 15908 22295
Notes: 1. Maximum undiluted propane capacities listed are based on a gauge pressure of 10-psi firststage setting and 1-psi pressure drop. Capacities in 1000 Btu/hr. 2. To convert to capacities at a gauge pressure of 5 psi with 10 percent (0.5 psi) pressure drop, multiply values by 0.606. To convert to capacities at a gauge pressure of 15 psi with 10 percent (1.5 psi) pressure drop, multiply values by 1.380.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
171
LP PIPE & TUBING SIZING TABLES
LP PIPE & TUBING SIZING TABLES
Pipe Sizing Between Second-Stage Regulator and Appliance:* Nominal Pipe Size, Schedule 80 PIPE 1 / 2” LENGTH, FT 0.546 10 20 30 40 50 60 80 100 125 150 200 250 300 350 400
207 142 114 98 87 78 67 59 53 48 41 36 33 30 28
3 / 4” 0.742
1” 0.957
11 / 4 ” 1.278
11 / 2 ” 1.5
2” 1.939
462 318 255 218 193 175 150 133 118 107 91 81 73 68 63
901 619 497 426 377 342 292 259 230 208 178 158 143 132 122
1924 1322 1062 909 805 730 625 553 491 444 380 337 305 281 261
2928 2012 1616 1383 1226 1111 951 842 747 677 579 513 465 428 398
5741 3946 3169 2712 2404 2178 1864 1652 1464 1327 1135 1006 912 839 780
3” 2.9
31 / 2 ” 3.364
4” 3.826
16503 11342 9108 7795 6909 6260 5358 4748 4208 3813 3264 2892 2621 2411 2243
24357 16740 13443 11506 10197 9239 7908 7009 6212 5628 4817 4269 3868 3559 3311
34137 23462 18841 16125 14292 12949 11083 9823 8706 7888 6751 5983 5421 4987 4640
Note: Maximum undiluted propane capacities listed are based on a 11-in. w.c. setting and 0.5in. w.c. pressure drop. Capacities in 1000 Btu/hr.
Pipe Sizing Between First-Stage and Second-Stage Regulators:*
Copper Tube Sizing Between Second-Stage Regulator and Appliance:*
Outside Diameter Copper Tubing, Type K
Outside Diameter Copper Tubing, Type K
TUBING 3 / 8” LENGTH, FT 0.305 30 40 50 60 70 80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1500 2000
284 243 216 195 180 167 157 148 119 102 90 82 75 70 66 62 56 52 48 45 43 34 29
1 / 2” 0.402
5 / 8” 0.527
3 / 4” 0.652
7 / 8” 0.745
587 502 445 403 371 345 374 306 246 210 186 169 155 144 136 128 116 107 99 93 88 71 60
1193 1021 905 820 754 702 659 622 500 428 379 343 316 294 276 260 236 217 202 189 179 144 123
2085 1785 1582 1433 1319 3227 1151 1087 873 747 662 600 552 514 482 455 412 379 353 331 313 251 215
2959 2532 2244 2033 1871 1740 1633 1542 1239 1060 940 851 783 729 654 646 585 538 501 470 444 356 305
TUBING 3 / 8” LENGTH, FT 0.305 10 20 30 40 50 60 80 100 125 150 200 250 300 350 400
45 31 25 21 19 17 15 13 11 10 9 8 7 7 6
1 / 2” 0.402
5 / 8” 0.527
3 / 4” 0.652
7 / 8” 0.745
93 64 51 44 39 35 30 27 24 21 18 16 15 14 13
188 129 104 89 79 71 61 54 48 44 37 33 30 28 26
329 226 182 156 138 125 107 95 84 76 65 58 52 48 45
467 321 258 221 196 177 152 134 119 108 92 82 74 68 63
Note: Maximum undiluted propane capacities listed are based on an 11-in. w.c. setting and 0.5-in. w.c. pressure drop. Capacities in 1000 Btu/hr.
Notes: 1. Maximum undiluted propane capacities listed are based on a gauge pressure of 10-psi first-stage setting and 1-psi pressure drop. Capacities in 1000 Btu/hr. 2. To convert to capacities at a gauge pressure of 5 psi setting with 10 percent (0.5 psi) pressure drop, multiply values by 0.606. To convert to capacities at a gauge pressure of 15 psi setting with 10 percent (1.5 psi) pressure drop, multiply values by 1.380. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
The VICTOR Propane Equipment Catalog
LP PIPE & TUBING SIZING TABLES
172 LP PIPE & TUBING SIZING TABLES Copper Tube Sizing Between First-Stage and Second-Stage Regulators* OUTSIDE DIAMETER COPPER TUBING, TYPE L OUTSIDE DIAMETER COPPER TUBING, TYPE L TUBING 3 / 8” 1 / 2” 5 / 8” 3 / 4” 7 / 8 ” TUBING 3 / 8” 1 / 2” 5 / 8” 3 / 4” 7 / 8” LENGTH, FT 0.315 0.430 0.545 0.666 0.785 LENGTH, FT 0.315 0.430 0.545 0.666 0.785 30 309 700 1303 2205 3394 350 82 185 345 584 898 40 265 599 1115 1887 2904 400 76 172 321 543 836 50 235 531 988 1672 2574 450 71 162 301 509 784 60 213 481 896 1515 2332 500 68 153 284 481 741 70 196 443 824 1394 2146 600 61 138 258 436 671 80 182 412 767 1297 1996 700 56 127 237 401 617 90 171 386 719 1217 1873 800 52 118 221 373 574 100 161 365 679 1149 1769 900 49 111 207 350 539 150 130 293 546 923 1421 1000 46 105 195 331 509 200 111 251 467 790 1216 1500 37 84 157 266 409 250 90 222 414 700 1078 2000 32 72 134 227 350 300 89 201 375 634 976
Note: Maximum undiluted propane capacities listed are based on a pressure of 10-psig first-stage setting and 1-psi pressure drop. Capacities in 1000 Btu/hr.
Polyethylene Plastic Pipe Sizing Between First-Stage and Second-Stage Regulators:* Nominal Outside Diameter (IPS) PLASTIC PIPE 1 / 2” LENGTH, SDR 9.33 FT (0.660) 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 450 500 600 700 800 900 1000 1500 2000
2143 1835 1626 1473 1355 1261 1183 1117 990 897 826 778 721 681 646 617 567 528 495 468 424 390 363 340 322 258 221
3 / 4” SDR 11.0 (0.860)
1” SDR 11.00 (1.077)
11 / 2 ” SDR 10.00 (1.328)
11 / 2 ” SDR 11.00 (1.554)
2” SDR 11.00 (1.943)
7744 6628 5874 5322 4896 4555 4274 4037 3578 3242 2983 2775 2603 2459 2336 2228 2050 1907 1789 1690 1531 1409 1311 1230 1162 933 798
13416 11482 10176 9220 8483 7891 7404 6994 6199 5616 5167 4807 4510 4260 4046 3860 3551 3304 3100 2928 2653 2441 2271 2131 2012 1616 1383
20260 17340 15368 13924 12810 11918 11182 10562 9361 8482 7803 7259 6811 6434 6111 5830 5363 4989 4681 4422 4007 3686 3429 3217 3039 2441 2089
36402 31155 27612 25019 23017 21413 20091 18978 16820 15240 14020 13043 12238 11560 10979 10474 9636 8965 8411 7945 7199 6623 6161 5781 5461 4385 3753
4292 3673 3256 2950 2714 2525 2369 2238 1983 1797 1653 1539 1443 1363 1294 1235 1136 1057 992 937 849 781 726 682 644 517 443
Notes: 1. Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1-psi pressure drop. Capacities in 1000 Btu/hr. 2. Dimensions in parentheses are inside diameter.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
173
LP PIPE & TUBING SIZING TABLES
Copper Tube Sizing Between Second-Stage Regulator and Appliance:*
Outside Diameter Refrigeration Tubing
Outside Diameter of Copper Refrigeration Tubing
TUBING 3 / 8” LENGTH, FT 0.311 30 299 40 256 50 227 60 206 70 189 80 176 90 165 100 156 150 125 200 107 250 95 300 86 350 79 400 74 450 69 500 65 600 59 700 54 800 51 900 48 1000 45 1500 36 2000 31
1 / 2” 0.436 726 621 551 499 459 427 401 378 304 260 230 209 192 179 168 158 144 132 123 115 109 87 75
5 / 8” 0.555 1367 1170 1037 939 864 804 754 713 572 490 434 393 362 337 316 298 270 249 231 217 205 165 141
3 / 4” 0.68 2329 1993 1766 1600 1472 1370 1285 1214 975 834 739 670 616 573 538 508 460 424 394 370 349 281 240
7 / 8” 0.785 3394 2904 2574 2332 2146 1996 1873 1769 1421 1216 1078 976 898 836 784 741 671 617 574 539 509 409 350
Notes: 1. Maximum undiluted propane capacities listed are based on a gauge pressure of 10-psi first-stage setting and 1-psi pressure drop. Capacities in 1000 Btu/hr. 2. To convert to capacities at a gauge pressure of 5-psi setting with 10 percent (0.5 psi) pressure drop, multiply values by 0.606. To con vert to capacities at a gauge pressure of 15-psi setting with 10 percent (1.5 psi) pressure drop, multiply values by 1.380.
Copper Tube Sizing Between Single-Stage or Second-Stage Regulator and Appliance:* Outside Diameter Copper Tubing, Type L TUBING 3 / 8” LENGTH, FT 0.315 10 49 20 34 30 27 40 23 50 20 60 19 80 16 100 14 125 12 150 11 200 10 250 9 300 8 350 7 400 7
1 / 2” 0.430 110 76 61 52 46 42 36 32 28 26 22 19 18 16 15
5 / 8” 0.545 206 141 114 97 86 78 67 59 52 48 41 36 33 30 28
3 / 4” 0.666 348 239 192 164 146 132 113 100 89 80 69 61 55 51 47
7 / 8” 0.785 536 368 296 253 224 203 174 154 137 124 106 94 85 78 73
TUBING 3 / 8” LENGTH, FT 0.311 10 20 30 40 50 60 80 100 125 150 200 250 300 350 400
47 32 26 22 20 18 15 14 12 11 9 8 8 7 6
1 / 2” 0.436
5 / 8” 0.555
3 / 4” 0.68
7 / 8” 0.785
115 79 63 54 48 43 37 33 29 26 23 20 18 17 16
216 148 119 102 90 82 70 62 55 50 43 38 34 32 29
368 253 203 174 154 139 119 106 94 85 73 64 58 54 50
536 368 296 253 224 203 174 154 137 124 106 94 85 78 73
Note: Maximum undiluted propane capacities listed are based on an 11-in. w.c. setting and 0.5-in. w.c. pressure drop. Capacities in 1000 Btu/hr.
Copper Tube Sizing Between 2-psi Service Regulator and Line Pressure Regulator:* Outside Diameter Copper Tubing, Type L TUBING (O.D.) 3 / 8 ” TUBING (I.D.) 0.315 LENGTH, FT 10 20 30 40 50 60 70 80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1500 2000
451 310 249 213 189 171 157 146 137 130 104 89 79 72 66 61 58 54 49 45 42 40 37 30 26
1/2” 0.430
5/8” 0.545
3/4” 0.666
7/8” 0.785
1020 701 563 482 427 387 356 331 311 294 236 202 179 162 149 139 130 123 111 102 95 89 84 68 58
1900 1306 1049 898 795 721 663 617 579 547 439 376 333 302 278 258 242 229 207 191 177 167 157 126 108
3215 2210 1774 1519 1346 1219 1122 1044 979 925 743 636 563 511 470 437 410 387 351 323 300 282 266 214 183
4948 3401 2731 2337 2071 1877 1727 1606 1507 1424 1143 979 867 786 723 673 631 596 540 497 462 434 410 329 282
Note: Maximum undiluted propane capacity based on a gauge pressure setting of 2 psig and 1-psi pressure drop. Capacities in 1000 Btu/hr.
Note: Maximum undiluted propane capacities listed are based on an 11-in. setting and a 0.5-in. w.c. drop. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
The VICTOR Propane Equipment Catalog
LP PIPE & TUBING SIZING TABLES
Pipe Sizing Between First-Stage and Second-Stage Regulators:*
LP PIPE & TUBING SIZING TABLES
174 LP PIPE & TUBING SIZING TABLES Propane Low Pressure (Standard)— Maximum Capacity of Omega Flex TracPipe™ in Thousands of BTU per Hour Propane Gas Gas Pressure: 11 in. W.C.
Pressure Drop: 0.5 in W.C. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet)
Size (EHD) 3/8" 15 1/2" 19
5
10
15
20
25
30
40
50
60
70
80
90
100
150
200
250
99
69
55
49
42
39
33
30
26
25
23
22
20
15
14
12
3/4"
1"
300 11
211
150
121
106
94
87
74
66
60
57
52
50
47
36
33
30
26
25
456
325
267
232
209
191
166
149
136
126
118
112
106
87
76
68
62
31
863
605
490
425
379
344
297
265
241
222
208
197
186
143
129
117
107
11/4"
37
1424
971
775
661
583
528
449
397
359
330
307
286
270
217
183
163
147
11/2"
46
2830
1993
1623
1404
1254
1143
988
884
805
745
696
656
621
506
438
390
357
2"
62
6547
4638
3791
3285
2940
2684
2327
2082
1902
1761
1647
1554
1475
1205
1045
934
854
Propane Medium Pressure — Maximum Capacity of Omega Flex TracPipe™ in Thousands of BTU per Hour Propane Gas Gas Pressure: 1/2 psi (12 – 14 in. W.C.)
Pressure Drop: 2.5 in W.C. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet)
Size (EHD) 3/8" 15 1/2" 19
5
10
15
20
25
30
40
50
60
70
80
90
100
150
200
250
300
222
159
131
114
102
93
81
73
67
62
58
55
52
43
37
33
30
491
353
290
254
228
209
182
164
150
140
131
124
118
97
85
76
70
3/4"
1094
782
642
559
501
459
399
358
328
304
285
269
256
210
183
164
136
25
1"
31
2512
1863
1720
1343
1106
976
883
825
771
719
673
632
596
470
398
352
320
11/4"
37
3476
2368
1891
1612
1424
1288
1099
971
877
805
748
700
661
528
449
397
359
11/2"
46
6383
4496
3663
3168
2830
2580
2230
1993
1818
1682
1571
1481
1404
1143
988
884
805
2"
62
14586 10330 8443
7317
6547
5980
5183
4638
4236
3923
3671
3462
3285
2684
2327
2082
1902
Propane Elevated Pressure 2 psi — Maximum Capacity of Omega Flex TracPipe™ in Thousands of BTU per Hour Propane Gas Gas Pressure: 2 psi
Pressure Drop: 1 psi. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet)
Size 3/8"
(EHD)
10
25
30
40
50
75
80
100
150
200
250
300
400
15
558
347
316
271
243
196
189
169
137
118
105
96
82
500 72
1/2"
19
1106
701
640
554
496
406
393
350
287
248
222
203
175
158
3/4"
25
2282
1464
1340
1165
1046
859
833
713
614
534
479
439
381
342
1"
31
4720
2954
2692
2323
2072
1685
1629
1454
1182
1019
910
829
716
638
11/4"
37
8983
5406
4888
4167
3682
2942
2837
2507
2003
1707
1510
1364
1163
1027
11/2"
46
15174
9549
8708
7529
6726
5480
5303
4738
3860
3337
2981
2719
2351
2101
2"
62
34203
21680
19891
17159
12551
12154
10877
8890
7705
6895
6296
6296
5457
4883
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com
LP PIPE & TUBING SIZING TABLES
175
Maximum Capacity of Omega Flex TracPipe™ in Thousands of BTU per Hour Propane Gas Gas Pressure: 2 psi
Pressure Drop: 1.5 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet)
Size 3/8"
(EHD)
10
25
30
40
15
817
1/2"
19
1588
3/4"
25
3237
2147
1978
1"
31
6838
4436
4070
50
75
80
100
525
481
1041
957
150
200
250
300
400
500
419
376
310
300
269
222
839
757
628
609
550
456
193
173
159
138
124
399
360
331
290
262
1739
1574
1312
1275
1153
962
845
765
705
619
560
3553
3198
2641
2561
2305
1903
1661
1495
1372
1198
1078
11/4"
37
11245
6769
6118
5216
4609
3682
3554
3139
2507
2139
1889
1707
1456
1287
11/2"
46
18624
11721
10689
9243
8256
6726
6511
5816
4738
4097
3659
3337
2886
2578
2"
62
41847
26527
24227
20996
18789
15357
14872
13308
10877
9426
8436
7705
6677
5975
400
500
Propane Elevated Pressure 5 psi — Maximum Capacity of Omega Flex TracPipe™ in Thousands of BTU per Hour Propane Gas Gas Pressure: 5 psi
Pressure Drop: 3.5 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet)
Size 3/8"
(EHD)
10
25
30
40
50
75
80
15
1065
664
1/2"
19
2061
1307
603
520
1193
1033
3/4"
25
4189
2686
2459
2139
1920
1577
1"
31
8945
5600
5102
4404
3929
3194
100
150
200
250
300
463
376
363
324
262
226
202
183
158
140
926
757
731
55656
535
464
416
379
328
294
1529
1310
1127
980
880
805
700
629
3090
2756
2241
1934
1726
1572
1356
1210
11/4"
37
17983
10823
9783
8342
7373
5888
5681
5020
4010
3419
3022
2732
2328
2058
11/2"
46
28580
17986
16403
14183
12670
10322
9990
8925
7271
6287
5616
5122
4429
3957
2"
62
63788
40436
36928
32004
28642
23409
22670
20287
16581
14369
12859
11745
10178
9108
The VICTOR Propane Equipment Catalog
LP PIPE & TUBING SIZING TABLES
Propane Elevated Pressure 2 psi —
NATURAL GAS PIPING & TUBING TABLES
176 NATURAL GAS PIPING & TUBING SIZING TABLES Pipe Sizing Table for Pressures Under 1 Pound Approximate Capacity of Pipes of Different Diameters and Lengths in Cubic Feet per Hour with Pressure Drop of 0.5 in. Water Column and 0.6 Specific Gravity PIPE SIZE OF SCHEDULE 40 STANDARD INTERNAL PIPE DIAMETER (IN.) (IN.) 1.00 1.049 1.25 1.380 1.50 1.610 2.00 2.067 2.50 2.469 3.00 3.068 3.50 3.548 4.00 4.026 5.00 5.047 6.00 6.065 8.00 7.981 10.00 10.020 12.00 11.938
TOTAL EQUIVALENT LENGTH OF PIPE (FT)
50 284 583 873 1681 2680 4738 6937 9663 17482 28308 58161 105636 167236
100 195 400 600 1156 1842 3256 4767 6641 12015 19456 39974 72603 114940
150 157 322 482 928 1479 2615 3828 5333 9649 15624 32100 58303 92301
200 134 275 412 794 1266 2238 3277 4565 8258 13372 27474 49900 78998
250 119 244 366 704 1122 1983 2904 4046 7319 11851 24350 44225 70014
300 108 221 331 638 1017 1797 2631 3666 6632 10738 22062 40071 63438
400 92 189 283 546 870 1538 2252 3137 5676 9190 18883 34296 54295
500 82 168 251 484 771 1363 1996 2780 5030 8145 16735 30396 48120
1000 56 115 173 333 530 937 1372 1911 3457 5598 11502 20891 33073
1500 45 93 139 267 426 752 1102 1535 2776 4496 9237 16776 26559
2000 39 79 119 229 364 644 943 1313 2376 3848 7905 14358 22731
Pipe Sizing Table for 2 Pounds Pressure Capacity of Pipes of Different Diameters and Lengths in Cubic Feet per Hour for an Initial Pressure of 2.0 psi with a 10 Percent Pressure Drop and a Gas of 0.6 Specific Gravity PIPE SIZE OF SCHEDULE 40 STANDARD INTERNAL PIPE DIAMETER (IN.) (IN.) 1.00 1.049 1.25 1.380 1.50 1.610 2.00 2.067 2.50 2.469 3.00 3.068 3.50 3.548 4.00 4.026 5.00 5.047 6.00 6.065 8.00 7.981 10.00 10.020 12.00 11.938
TOTAL EQUIVALENT LENGTH OF PIPE (FT)
50 1112 2283 3421 6589 10501 18564 27181 37865 68504 110924 227906 413937 655315
100 764 1569 2351 4528 7217 12759 18681 26025 47082 76237 156638 284497 450394
150 614 1260 1888 3636 5796 10246 15002 20899 37809 61221 125786 228461 361682
200 525 1079 1616 3112 4961 8769 12840 17887 32359 52397 107657 195533 309553
250 300 466 422 956 866 1432 1298 2758 2499 4396 3983 7772 7042 11379 10311 15853 14364 28680 25986 46439 42077 95414 86452 173297 157020 274351 248582
400 500 1000 1500 361 320 220 177 741 657 452 363 1111 984 677 543 2139 1896 1303 1046 3409 3022 2077 1668 6027 5342 3671 2948 8825 7821 5375 4317 12293 10895 7488 6013 22240 19711 13547 10879 36012 31917 21936 17616 73992 65578 45071 36194 134389 119106 81861 65737 212754 188560 129596 104070
2000 151 310 465 896 1427 2523 3694 5147 9311 15077 30977 56263 89071
Pipe Sizing Table for 10 Pounds Pressure Capacity of Pipes of Different Diameters and Lengths in Cubic Feet per Hour for an Initial Pressure of 10.0 psi with a 10 Percent Pressure Drop and a Gas of 0.6 Specific Gravity PIPE SIZE OF SCHEDULE 40 STANDARD INTERNAL PIPE DIAMETER (IN.) (IN.) 50 100 1.00 1.049 3259 2240 1.25 1.380 6690 4598 1.50 1.610 10024 6889 2.00 2.067 19305 13268 2.50 2.469 30769 21148 3.00 3.068 54395 37385 3.50 3.548 79642 54737 4.00 4.026 110948 76254 5.00 5.047 200720 137954 6.00 6.065 325013 223379 8.00 7.981 667777 458959 10.00 10.020 1212861 833593 12.00 11.938 1920112 1319682
TOTAL EQUIVALENT LENGTH OF PIPE (FT)
150 1798 3692 5532 10655 16982 30022 43956 61235 110782 179382 368561 669404 1059751
200 1539 3160 4735 9119 14535 25695 37621 52409 94815 153527 315440 572924 907010
250 300 1364 1236 2801 2538 4197 3802 8082 7323 12882 11672 22773 20634 33343 30211 46449 42086 84033 76140 136068 123288 279569 253310 507772 460078 803866 728361
400 500 1058 938 2172 1925 3254 2884 6268 5555 9990 8854 17660 15652 25857 22916 36020 31924 65166 57755 105518 93519 216800 192146 393767 348988 623383 552493
1000 1500 2000 644 517 443 1323 1062 909 1982 1592 1362 3818 3066 2624 6085 4886 4182 10757 8638 7393 15750 12648 10825 21941 17620 15080 39695 31876 27282 64275 51615 44176 132061 106050 90765 239858 192614 164853 379725 304933 260983
To Order: (800) 243-9360 • CT: (800) 228-0508 • FAX: (800) 274-2004 • www.victormfg.com