INDUSTRY STANDARDS

NFPA 2112

NFPA 70E

Standard for Flash Fire Protection

Standard for Electrical Safety in the Workplace

NFPA 2112 provides informative guidelines for specialized flash fire resistant clothing. NFPA 2112 compliant garments protect workers in hazardous industrial occupations where a flash fire (a sudden, intense fire which is short in duration but severe in potential danger) is always a risk. NFPA 2112 states, “The

Updated in 2018, NFPA 70E now uses PPE categories which are based on an incident energy analysis. The standard gives 4 categories of PPE, with each category including the minimum Arc Thermal Performance Value (ATPV) for the required PPE.

standard shall specify the minimum requirements and test methods for flame-resistant fabrics and components and the design and certification requirements for garments for use in areas at risk from flash fires.” To comply with NFPA 2112, FR garments must meet the following 4 criteria:

4 NFPA 2112 FR Garments Criteria

1

All flame resistant clothing items must achieve a 50% or less predicted body burn

2 3

PPE Category 1 Clothing

ARC-rated long sleeve shirt or jacket and ARC-rated pants or ARC-rated coverall (minimum ATPV 4 cal/cm²)

Face & Head Protection

ARC-rated face shield or ARC-rated flash suit hood

Hand Protection

Heavy duty leather gloves

As Needed

ARC-rated jacket, rainwear, parka, hard hat liner

PPE Category 2

All flame resistant clothing items must have appropriate labeling in an easy-to-see location

ARC-rated long sleeve shirt or jacket and ARC-rated pants or ARC-rated coverall (minimum ATPV 8 cal/cm2)

Face & Head Protection

ARC-rated face shield and ARC-rated balaclava or ARC-rated flash suit hood

Hand Protection

Heavy duty leather gloves

As Needed

ARC-rated jacket, rainwear, parka, hard hat liner

All flame resistant clothing items must meet each of the NFPA 2112 requirements and tests, and should be UL certified (the UL certification label should either be attached to the flame resistant garment label, or be positioned right next to it)

Minimum ATPV 25 cal/cm2

Clothing

ARC-rated long sleeve shirt or jacket and ARC-rated pants; ARC-rated coverall; ARC-rated flash suit jacket and ARC-rated flash suit pants (minimum ATPV 25 cal/cm2)

Face & Head Protection

ARC-rated flash suit hood

Hand Protection

ARC-rated gloves or rubber insulating gloves and leather protectors

As Needed

ARC-rated jacket, rainwear, parka, hard hat liner

PPE Category 4

4

Minimum ATPV 8 cal/cm2

Clothing

PPE Category 3 All flame resistant clothing items must defy melting, dripping, or after-flame burning

Minimum ATPV 4 cal/cm2

Minimum ATPV 40 cal/cm2

Clothing

ARC-rated flash suit jacket and ARC-rated flash suit pants; ARC-rated long sleeve shirt or jacket and ARC-rated pants; ARC-rated coverall; (minimum ATPV 40 cal/cm2)

Face & Head Protection

ARC-rated flash suit hood

Hand Protection

Rubber insulating gloves and leather protectors or ARC-rated gloves

As Needed

ARC-rated jacket, rainwear, parka, hard hat liner