To Request a Quote, Please Contact Us:
Tankless Water Heaters
828-735-1978 or 828-538-4311 sales@jxtcompany.com
HIGH-EFFICIENCY (NONCONDENSING TECHNOLOGY)
SUPER-HIGH-EFFICIENCY (CONDENSING TECHNOLOGY)
HE Series
HE+ Series
SE Series
( V MODELS )
( RL MODELS )
( RUCS/RUS MODELS )
(RU MODELS )
( RUR MODELS )
0.81
0.81-0.82
0.85-0.90
0.91-0.93
0.93
AVAILABLE IN NATURAL GAS OR PROPANE
3
3
3
3
3
INDOOR AND OUTDOOR VERSIONS AVAILABLE
3
3
3
3
3
UNIFORM ENERGY FACTOR
SENSEI™ SE+ Series
WI-FI READY
RECIRCULATION SOLUTION MADE POSSIBLE WITH CIRC-LOGICTM TECHNOLOGY
3
3
3
ISOLATION VALVES
3
3
3
THERMACIRC360TM — (RECIRC WITH OR WITHOUT DEDICATED LINE)
3
INCLUDES CONTROL-R™ WI-FI MODULE FOR RECIRCULATION CONTROL
3
Key Benefits • •
• •
Never think about hot water again. Available in multiple sizes, our innovative technology provides an endless supply of hot water whenever and wherever it’s needed – even for simultaneous multiple fixtures. Minimum output. Maximum space. About the size of a small suitcase, the Rinnai can be tucked in a small crawl space, attic or basement. These wall-mounted units can be installed on the interior wall of the home to free up valuable space. Earth-friendly efficiency. Compact heat exchanger design, longer product lifespan compared to a traditional tank and recyclable parts means less waste in landfills. Vertically integrated. All key components are manufactured and assembled by Rinnai – for the highest quality you have come to expect from these products. 2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
NEW! SENSEI SE+ and SE Series Condensing Tankless Water Heater New SENSEI™ Tankless Water Heaters, with an enhanced combustion system, provide all the traditional benefits of a Rinnai, but with a better experience for installers and users. SENSEI provides an endless supply of hot water, energy savings, a space saving design and environmentally friendly features. Rinnai’s dual heat exchanger and condensing technology provides up to a .93 Uniform Energy Factor, ENERGY STAR® certification and up to 40 percent less energy use* than a traditional tank. New Features • Accepts 2" dual pipe or concentric venting • Flexible gas intake allowing for 1/2-inch gas line with zero governor gas valve • Longest 2" vent runs - up to 65' available with new turbo fan feature • Enhanced freeze protection via vent check valves • New rotating isolation valve and adjustable mounting bracket
Tankless Water Heater Changes Max BTU Input
Existing Part Number
New Part Number
199,000
RUC98i / RU98e
RU199i/e
180,000
RUC90i / RU90e
RU180i/e
160,000 Residential (Indoor / Outdoor)
Commercial (Indoor / Outdoor)
RU160i/e
152,000
RUC80i / RU80e
130,000
New
RU130i/e
199,000
RUR98i / RUR98e
RUR199i/e
160,000
New
RUR160i/e
199,000
C199i / C199e
CU199i/e
160,000
New
CU160i/e
SE+ Series (Legacy Models) Condensing Tankless Water Heater (While Supplies Last) High Efficiency, HE+ and HE Series Non-Condensing Tankless Water Heater Rinnai HE and HE+ Series Tankless Water Heaters, our non-condensing line of tankless water heaters, provide homeowners with an endless supply of hot water, energy savings, a compact design and environmentally friendly features. These units provide a .81 Uniform Energy Factor, and up to 40 percent less energy use* than a traditional tank.
* As based on the average cost to run an electric tank water heater per the Department of Energy (DOE) Average Energy Costs (doe.gov) 2017.
2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SENSEI™ Tankless Water Heaters (Condensing) With an enhanced combustion design, the Rinnai SENSEI Tankless Water Heater provides a better experience for both users and installers. Like all Rinnai Tankless Water Heaters, it’s also vertically integrated. That means all key components are manufactured by Rinnai — to ensure Rinnai quality.
SENSEI™ SE+ Series (Replaces Previous SE+ Series) Model Number
Product Description
Product Dimensions (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
RU130iN
Indoor CTWH 130k Btu 7 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 7 GPM 1 l/min to 26 l/min
0.91/0.95
15,000
130,000
$1,574
RU130iP
Indoor CTWH 130k Btu 7 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 7 GPM 1 l/min to 26 l/min
0.91/0.95
15,000
130,000
$1,574
RU130eN
Outdoor CTWH 130k Btu 7 GPM max w/Valve
14.76 x 33.86 x 22.05
71
0.26 GPM to 7 GPM 1 l/min to 26 l/min
0.92/0.95
15,000
130,000
$1,574
RU130eP
Outdoor CTWH 130k Btu 7 GPM max w/Valve
14.76 x 33.86 x 22.05
71
0.26 GPM to 7 GPM 1 l/min to 26 l/min
0.92/0.95
15,000
130,000
$1,574
RU160iN
Indoor CTWH 160k Btu 9 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.95
15,000
160,000
$1,718
RU160iP
Indoor CTWH 160k Btu 9 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.95
15,000
160,000
$1,718
RU160eN
Outdoor CTWH 160k Btu 9 GPM max w/Valve
14.76 x 33.86 x 22.05
71
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.96
15,000
160,000
$1,718
RU160eP
Outdoor CTWH 160k Btu 9 GPM max w/Valve
14.76 x 33.86 x 22.05
71
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.96
15,000
160,000
$1,718
RU180iN
Indoor CTWH 180k Btu 10 GPM max w/Valve
74
0.26 GPM to 10 GPM 1 l/min to 38 l/min
0.93/0.95
15,000
180,000
$1,886
14.76 x 33.86 x 22.05
2018 SUGGESTED LIST PRICE (USD) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
SENSEI™ SE+ Series Condensing Tankless Water Heaters (Replaces Previous SE+ Series) Cont’d Model Number
Product Description
Product Dimensions (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
RU180iP
Indoor CTWH 180k Btu 10 GPM max w/Valve
14.76 x 33.86 x 22.05
74
0.26 GPM to 10 GPM 1 l/min 38 l/ min
0.93/0.95
15,000
180,000
$1,886
RU180eN
Outdoor CTWH 180k Btu 10 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 10 GPM 1 l/min to 38 l/min
0.93/0.96
15,000
180,000
$1,886
RU180eP
Outdoor CTWH 180k Btu 10 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 10 GPM 1 l/min to 38 l/min
0.93/0.96
15,000
180,000
$1,886
RU199iN
Indoor CTWH 199k Btu 11 GPM max w/Valve
14.76 x 33.86 x 22.05
74
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,054
RU199iP
Indoor CTWH 199k Btu 11 GPM max w/Valve
14.76 x 33.86 x 22.05
74
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,054
RU199eN
Outdoor CTWH 199k Btu 11 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,054
RU199eP
Outdoor CTWH 199k Btu 11 GPM max w/Valve
14.76 x 33.86 x 22.05
73
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,054
2018 SUGGESTED LIST PRICE (USD) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
FEATURING
SENSEI™ SE+ Series with ThermaCirc360™ Condensing Tankless Water Heaters (Replaces Previous SE+ Series) Cont’d SENSEI™ SE+ Series with ThermaCirc360™ Model Number
Product Description
Product Dimensions (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
RUR160iN
Indoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
83
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.95
15,000
160,000
$2,250
RUR160iP
Indoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
83
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.95
15,000
160,000
$2,250
RUR160eN
Outdoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
81
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.96
15,000
160,000
$2,250
RUR160eP
Outdoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
81
0.26 GPM to 9 GPM 1 l/min to 34 l/min
0.93/0.96
15,000
160,000
$2,250
RUR199iN
Indoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
84
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,558
RUR199iP
Indoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
84
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,558
RUR199eN
Outdoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
83
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
$2,558
RUR199eP
Outdoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module
83
0.26 GPM to 11 GPM 1 l/min to 42 l/min
0.93/0.96
15,000
199,000
WirelessModule_Included_sticker_5-press.pdf
C
M
Y
CM
MY
CY
CMY
K
Wi-Fi Ready
2
$2,558 9/28/18
5:28 PM
Everything You Need for Control of Recirculation, Right in the Box.
CONTROL-R™ RECIRCULATION MODULE INCLUDED (PN: RWM101) The Control-R™ Module must be installed to control recirculation.
NOTES:
• Control-R™ Wi-Fi Module included with SENSEI™ RUR models.
• Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. • For residential applications, the heat exchanger warranty will be 15 years or 12,000 operation hours, whichever occurs first. Note: From date of purchase, period of coverage is reduced to 8 years or 12,000 operation hours, whichever occurs first, if the Rinnai water heater temperature settings exceeds 160° F (71°C). • The integrated controller has a 1 year warranty on parts. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 6 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
SENSEI™ Series for Commercial Applications (Replaces Previous C199) Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
List Price (U.S.)
CU199iN
Commercial Indoor CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 31.3
64
22.1 x 14.8 x 33.9
74
97%
$2,200
CU199iP
Commercial Indoor CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 31.3
64
22.1 x 14.8 x 33.9
74
97%
$2,200
CU199eN
Commercial Outdoor CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 28.4
64
22.1 x 14.8 x 33.9
72
97%
$2,200
CU199eP
Commercial Outdoor CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 28.4
64
22.1 x 14.8 x 33.9
72
97%
$2,200
CU160eN
Commercial Outdoor CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 28.4
62
22.1 x 14.8 x 33.9
71
97%
$1,864
CU160eP
Commercial Outdoor CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 28.4
62
22.1 x 14.8 x 33.9
71
97%
$1,864
CU160iN
Commercial Indoor CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 31.3
62
22.1 x 14.8 x 33.9
72
97%
$1,864
CU160iP
Commercial Indoor CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 31.3
62
22.1 x 14.8 x 33.9
72
97%
$1,864
NOTES: • MCC-91 temperature controller included with commercial units.
2018 SUGGESTED LIST PRICE (USD) • Page 7 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Tankless Water Heaters Rinnai Tankless Water Heaters deliver innovation and technological leadership in Tankless Water Heating design while providing homeowners and businessowners with an endless supply of hot water, energy savings, a space saving design and environmental benefits. Rinnai offers ease of installation now with more venting options right out to the box.
SE+ Series with ThermaCirc360™ (Legacy Condensing Models) Model Number
Product Description
Product Dimensions - Inches (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/Legacy EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
82
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,798
0.92/0.95
15,200
199,000
$2,798
RUR98iN
Indoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34 x 22 Pass w/Valve
RUR98iP
Indoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34x22 Pass w/Valve
82
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
RUR98eN
Outdoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34 x 22 Pass w/Valve
82
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,798
RUR98eP
Outdoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34 x 22 Pass w/Valve
82
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,798
(Limited Quantities)
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. • Full Freight Allowed for 16 pc. and greater, freight added to invoice for less than 16 pc. • When ordering, please specify gas type with a “P” for Propane and a “N” for Natural Gas. • All RUR Legacy Condensing models include a MC-195T-US Temperature Controller • All units, with the exception of RUR models, that are used for applications requiring temperatures above 140°F will require an MCC-91-2W controller (sold separately). RUR models cannot be used in applications exceeding 140°F. • All Product comply with California Lead-Free AB1953 Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 8 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
SE+ Series (Legacy Condensing Models) Model Number
Product Description
Product Dimensions - Inches (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/ Legacy EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
RUC80iN
Indoor CTWH 157k Btu 8.0 GPM max w/Valve
14.5 x 34 x 22
69
0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min
0.92/0.96
15,200
152,000
$1,718
RUC80iP
Indoor CTWH 157k Btu 8.0 GPM max w/Valve
14.5 x 34 x 22
69
0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min
0.92/0.96
15,200
152,000
$1,718
RUC90iN
Indoor CTWH 180k Btu 9.0 GPM max w/Valve
14.5 x 34 x 22
71
0.26 GPM to 9.0 GPM 1 l/min to 29 l/min
0.92/0.96
15,200
180,000
$1,886
RUC90iP
Indoor CTWH 180k Btu 9.0 GPM max w/Valve
14.5 x 34 x 22
71
0.26 GPM to 9.0 GPM 1 l/min to 29 l/min
0.92/0.96
15,200
180,000
$1,886
RUC98iN
Indoor CTWH 199k Btu 9.8 GPM max w/Valve
14.5 x 34 x 22
76
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,054
RUC98iP
Indoor CTWH 199k Btu 9.8 GPM max w/Valve
14.5 x 34 x 22
76
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,054
RU80eN
Outdoor 152K Btu max flow 8.0 GPM w/Valve
14.5 x 34 x 22
67
0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min
0.92/0.96
15,200
152,000
$1,718
RU80eP
Outdoor 152K Btu max flow 8.0 GPM w/Valve
14.5 x 34 x 22
67
0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min
0.92/0.96
15,200
152,000
$1,718
RU90eN
Outdoor CTWH 180k Btu 9.0 GPM max w/Valve
14.5 x 34 x 22
71
0.26 GPM to 9.0 GPM 1 l/min to 29 l/min
0.92/0.96
15,200
180,000
$1,886
RU90eP
Outdoor CTWH 180k Btu 9.0 GPM max w/Valve
14.5 x 34 x 22
71
0.26 GPM to 9.0 GPM 1 l/min to 29 l/min
0.92/0.96
15,200
180,000
$1,886
RU98eN
Outdoor 199K Btu max flow 9.8 GPM w/Valve
14.5 x 34 x 22
74
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,054
RU98eP
Outdoor 199K Btu max flow 9.8 GPM w/Valve
74
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.92/0.95
15,200
199,000
$2,054
14.5 x 34 x 22
NOTES: • All RUC Indoor units, with exception of RUCS, include an integrated MC-91-2US controller, 98° - 140°F. (Factory Setting 120°F) / RUCS has built-in status monitor. • All RU Outdoor units, with exception of RUS, include an MC-91-2US controller in the box, 98° - 140°F. (Factory Setting 120°F) / RUS has built-in status monitor. • SE+ Series Legacy Condensing models (exluding RUR models) include a MC-91-2US Temperature Controller
2018 SUGGESTED LIST PRICE (USD) • Page 9 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SE Series (Condensing Models) Model Number
RUCS65iN
RUCS65iP
Product Description
Product Dimensions - Inches (W x H x D)
Indoor CTWH 160K Btu 6.5 GPM 14.5 x 34 x 22
Indoor CTWH 160K Btu 6.5 GPM 14.5 x 34 x 22
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/ Legacy EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
63
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.85/0.93
10,300
130,000
$1,362
63
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.85/0.93
10,300
130,000
$1,362
RUS65eN
Outdoor CTWH 160K Btu 6.5 GPM
14.5 x 34 x 22
62
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.86/0.93
10,300
130,000
$1,362
RUS65eP
Outdoor CTWH 160K Btu 6.5 GPM
14.5 x 34 x 22
62
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.86/0.93
10,300
130,000
$1,362
RUCS75iN
Indoor CTWH 160K Btu 7.5 GPM
14.5 x 34 x 22
63
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.90/0.93
10,300
160,000
$1,572
RUCS75iP
Indoor CTWH 160K Btu 7.5 GPM
14.5 x 34 x 22
63
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.90/0.93
10,300
160,000
$1,572
RUS75eN
Outdoor CTWH 160K Btu 7.5 GPM 14.5 x 34 x 22
63
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.89/0.93
10,300
160,000
$1,572
RUS75eP
Outdoor CTWH 160K Btu 7.5 GPM 14.5 x 34 x 22
63
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.89/0.93
10,300
160,000
$1,572
NOTES: • All RUC Indoor units, with exception of RUCS, include an integrated MC-91-2US controller, 98° - 140°F. (Factory Setting 120°F) / RUCS has built-in status monitor. • All RU Outdoor units, with exception of RUS, include an MC-91-2US controller in the box, 98° - 140°F. (Factory Setting 120°F) / RUS has built-in status monitor.
2018 SUGGESTED LIST PRICE (USD) • Page 10 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
HE+ Series (Non-Condensing) Model Number
Product Description
Product Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/ Legacy EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
RL75iN
Indoor 180k Btu 7.5 GPM max w/Valves
13 x 31 x 17.5
49
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,503
RL75iP
Indoor 180k Btu 7.5 GPM max w/Valve
13 x 31 x 17.5
49
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,503
RL75eN
Outdoor 180k Btu 7.5 GPM max w/Valve
13 x 31 x 17.5
49
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,503
RL75eP
Outdoor 180k Btu 7.5 GPM max w/Valve
13 x 31 x 17.5
49
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,503
RL94iN
Indoor 199k Btu 9.4 GPM max w/ Valve
13 x 31 x 17.5
54
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,828
RL94iP
Indoor 190k Btu 9.4 GPM max w/ Valve
13 x 31 x 17.5
54
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,828
RLX94iN
Indoor 192k Btu 9.8 GPM max w/ Valve
13 x 31 x 17.5
55
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.82/0.82
10,300
192,000
$1,828
RL94eN
Outdoor 199k Btu 9.4 GPM max w/Valve
13 x 31 x 17.5
54
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,828
RL94eP
Outdoor 190k Btu 9.4 GPM max w/Valve
54
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,828
13 x 31 x 17.5
2018 SUGGESTED LIST PRICE (USD) • Page 11 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
HE Series (Non-Condensing) Model Number
Product Description
Product Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Hot Water Capacity Range
UEF/ Legacy EF
Min Heating Input (Btu/h)
Max Heating Input (Btu/h)
List Price (U.S.)
V53eN
Residential, Outdoor, max Btu 120,000, 5.3 GPM (Superceeded by V53DeN)
18.5 x 27 x 10.5
39
0.6 GPM to 5.3 GPM 2.3 l/min to 20.1 l/min
0.81/0.82
19,000
120,000
$899
V53eP
Residential, Outdoor, max Btu 120,000, 5.3 GPM (Superceeded by V53DeP)
18.5 x 26.5 x 10.5
39
0.6 GPM to 5.3 GPM 2.3 l/min to 20.1 l/min
0.81/0.82
20,200
120,000
$899
V53DeN
Residential, Outdoor, max Btu 120,000, 5.3 GPM
18.5 x 27.4 x 11.8
33
0.4 GPM to 5.3 GPM 1.5 l/min to 20 l/min
0.81/0.82
15,500
120,000
$899
V53DeP
Residential, Outdoor, max Btu 120,000, 5.3 GPM
18.5 x 27.4 x 11.8
33
0.4 GPM to 5.3 GPM 1.5 l/min to 20 l/min
0.81/0.82
15,500
120,000
$899
V65iN
Residential, Indoor, max. Btu 150,000, 6.3 GPM
13 x 30 x 17.5
50
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.80/0.82
10,300
150,000
$1,101
V65iP
Residential, Indoor, max. Btu 150,000, 6.3 GPM
17.32 x 30.51 x 12.8
50
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.80/0.82
10,300
150,000
$1,101
V65eN
Residential, Outdoor, max. Btu 150,000, 6.3 GPM
13 x 30 x 17.5
47
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.79/0.82
10,300
150,000
$1,023
V65eP
Residential, Outdoor, max. Btu 150,000, 6.3 GPM
17.32 x 30.51 x 13
47
0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min
0.79/0.82
10,300
150,000
$1,023
V75iN
Residential, Indoor, max. Btu, 180,000, 7.5 GPM
13 x30 x17.5
50
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.80/0.82
10,300
180,000
$1,345
V75iP
Residential, Indoor, max. Btu, 180,000, 7.5 GPM
12.8 x 30.51 x 17.32
50
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,345
V75eN
Residential, Outdoor, max. Btu, 180,000, 7.5 GPM
13 x 30 x 17.5
47
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,345
V75eP
Residential, Outdoor, max. Btu, 180,000, 7.5 GPM
12.8 x 30.51 x 17.32
47
0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min
0.81/0.82
10,300
180,000
$1,345
V94iN
Residential, Indoor, max. Btu, 199,000, 9.8 GPM
13 x 30 x 17.5
50
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,579
V94iP
Residential, Indoor, max. Btu, 199,000, 9.8 GPM
13 x 31 x 17.5
50
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,579
V94XiN
Residential, Indoor, max. Btu 192,000, 9.8 GPM
13 x 31 x 17.5
50
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.82/0.82
10,300
192,000
$1,579
V94eN
Residential, Outdoor, max. Btu, 199,000, 9.8 GPM
13 x 30 x 17.5
48
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,579
V94eP
Residential, Outdoor, max. Btu, 199,000, 9.8 GPM
13 x 30 x 17.5
48
0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min
0.81/0.82
10,300
199,000
$1,579
NEW
NEW
NOTES: • V53 models only with status indicator; no controller
2018 SUGGESTED LIST PRICE (USD) • Page 12 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Accessories for Tankless Water Heaters Controllers Product ID
Product Description
List Price (U.S.)
RWM101
Control-R™ Wi-Fi Module
$125
MC-91-2S
Temperature Controller Silver
$89
MC-91-2W
Temperature Controller White
$89
MCC-91-2W
Commercial Temperature Controller White
$120
BC-100V-1S
Bath Controller Silver (limited quantity)
$145
BC-100V-1W
Bath Controller White (limited quantity)
$145
MC-100V-1S
Controller Silver
$128
MC-100V-1W
Controller White (limited quantity)
$128
RWM101
Control-R™ Wi-Fi Module
$125
MC-195T-US
Recirculation Timer & Temperature Controller
$170
Demand Recirculation Accessories
GTK15
Pump with Timer For Circ-Logic (SE+, HE+)
$320
RWMPB01*
Control-R™ Wi-Fi Push Button (1PB)
$50
RWMMS01
Control-R™ Wi-Fi Motion Sensor (1MS)
$200
Demand Recirculation Kits for SE+ Series featuring ThermaCirc360™ RWMKT01
Control-R™ Wireless Demand Recirculation Kit (Module, 1PB)
$175
RWMKT03
Control-R™ Wireless Demand Recirculation (Module, 1PB, 1MS)
$400
Demand Recirculation Kits for HE+ and SE+ Series featuring Circ-Logic RWMKT01P
Control-R™ Wireless Demand Recirculation (Pump Kit, 1PB)
$525
RWMKT03P
Control-R™ Wireless Demand Recirculation (Pump Kit, 1PB, 1TS)
$750
MIVK-T-LW
Isolation Valve Kit (excludes SENSEI™)
$109
107000284
Isolation Valve Kit (SENSEI™)
$109
REU-PVA-4
Pressure Valve Activating (Legacy SE+, RUC)
$77
Other Accessories
NEW
NEW
• •
804000074
Condensate Neutralizer Kit
$85
809000114
Condensate Neutralizer Refill
$30
103000038
ScaleCutter System
$210
103000039
ScaleCutter Refill Cartridge
$110
104000059
Freeze Protection, Drain Down Kit (SE, HE, HE+)
$400
104000285
Freeze Protection, Drain Down Kit (SENSEI™)
$600
Stand alone venting / accessory orders require a $2,000 minimum to qualify for (FFA) Full Freight Allowed. FOB Rinnai Georgia, Nevada, Pennsylvania. SENSEI™ Isolation Valve
2018 SUGGESTED LIST PRICE (USD) • Page 13 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Accessories for Tankless Water Heaters (Cont’d) Connection Cables NEW
REU-EZC-2*
EZConnect™ (2 Units) (SE+/SE/HE+/HE)
$45
REU-EZC-1-US
EZConnect™ Accessory Cable (2 Units) (SE/HE+/HE)
$22
REU-MSB-M
Multi-Unit Control Kit (+2 Units) (MSB + Multi-Unit Cable) (SE/HE+/HE)
$150
REU-MSB-C2
MSB Cable (+2 Units) (SE/HE+/HE)
$65
REU-MSB-C1
Multi-unit Cable (+2 Units) (SE/HE+/HE)
$46
NEW
REU-OPU3
BMS/Air Handler (Replaces 103000037) (SE+/SE/HE+/HE)
$30
103000037
Domestic Priority Switch for Hydronic Air Handler (SE/HE+/HE)
$30
REU-CSA-C1
Cascade harness 3m (Commercial)
$35
REU-CSA-C2
Cascade harness 8m (Commercial)
$65
PCD07-SM
Pipe Cover for SE+
$128
PCD07-EW
Pipe Cover for SE (Euro White)
$128
Pipe Enclosures
PCD03-SM2
Pipe Cover for HE+
$128
NEW
PCD03-EWV
Pipe Cover for HE (excludes V53De)
$128
NEW
PCD01-EWV
Pipe Cover for V53De (Euro White)
$116
PC-20-W
Pipe Cover for V53e (Euro White)
$116
PCD07-IB
Pipe Cover for Commercial (Indigo Black)
$128
PCD07-SM-BP
Bottom Plate for SE+
$36
PCD07-EW-BP
Bottom Plate for SE (Euro White)
$36
PCD03-SM2-BP
Bottom Plate for HE+/HE/V53
$36
PCD07-IB-BP
Bottom Plate for Commercial (Indigo Black)
$50
RGB-CTWH-4
Recess Box for Condensing Tankless (SENSEI™ SE+, SE Series, Commercial)
$405
RGB-CTWH-3
Recess Box for Condensing SE Series (RUCS and RUS Models)
$405
RGB-25U-C
Recess Box for HE, HE+ Series (excludes V53e Models)
$159
Recess Boxes
RGB-20-U
Recess Box for V53e/V53De
$252
RGB-CTWH-2
Recess Box for Legacy Condensing Models (KB and KBP Generation)
$405
RGB-25U-MSAL-C
Universal Moisture Seal Recess Box for HE, HE+ Series (excludes V53e Models)
$340
109000724
Replacement Door Kit (SENSEI™ SE+)
$0
109000535
Replacement Door Kit for SE
$0
109000824
Replacement Door Kit for V53De
$0
109000284
Replacement Door Kit (Legacy Condensing Models)
$0
109000283
RGB-25U/MSAL Replacement Door Kit (for fitting VC units into old RGB-25U/MSAL boxes)
$0
104000050
RGB-25W Replacement Door Kit (for fitting R94/75LSe units into RGB-25W/MS recess boxes)
$0
104000055
RGB-25MSW Replacement Door Kit (for fitting R94/R75LSe units into RGB-25MSW recess boxes)
$0
NOTES: • Accessory cable used for Freeze Protection, BMS and Air Handler
2018 SUGGESTED LIST PRICE (USD) • Page 14 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Accessories for Tankless Water Heaters (Cont’d) Conversion Kits (LP to NG or NG to LP) (Includes 2 Data Plates: 2 Orifices) 103000076
Conversion Kit - RUR199i, RU199i, CU199i
$28
103000077
Conversion Kit - RUR199e, RU199e, CU199e
$28
103000078
Conversion Kit - RU180i
$28
103000079
Conversion Kit - RU180e
$28
103000080
Conversion Kit - RU160i, RUR160i, CU160i
$28
103000081
Conversion Kit - RU160e, RUR160e, CU160e
$28
103000082
Conversion Kit - RU130i
$28
103000083
Conversion Kit - RU130e
$28
2018 SUGGESTED LIST PRICE (USD) • Page 15 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER
• • • • •
Installation Type
Internal (Indoor) Residential Applications. Manufactured (Mobile) Home Certified
Model Numbers
RU199i (REU-N3237FF-US) RU180i (REU-N2934FF-US) RU160i (REU-N2530FF-US) RU130i (REU-N2024FF-US)
Approved Gas Types
Natural and Propane
Uniform Energy Factor (UEF)
RU199i, RU180i, RU160i: RU130i:
0.93 0.91
Energy Factor (EF) (Canada)
RU199i: RU180i, RU160i, RU130i:
0.96 0.95
High Altitude Approved
Up to 10,200 ft (3,109 m)
Water Flow Control
Water Flow Sensor, Electronic Water Control and Bypass Control
Controller
Standard: Integrated Controller Optional: MC-195T-US, MC-100V-1US, BC-100V-1US, MCC-91-2US
Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe)
Certifications
Non-Direct Vent (Room Air)
AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
Common Vent (Direct Vent and Room Air)
Warranty
Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes 2 in. (51 mm) 3 in. (76 mm)
• Heat Exchanger: 15 years or 12,000 operation hours, whichever
Vent Lengths
65 ft (20 m)
occurs first
• All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year
150 ft (46 m)
Safety Devices
Concentric Vent Sizes
2 in. X 4 in.
3 in. X 5 in.
Vent Lengths
65 ft (20 m)
150 ft (46 m)
Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase
• • • •
Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2) and Self-Tapping Screws (x2)
Compact Design to Save Space
Additional Features
Wi-Fi Technology for Remote Monitoring and Management
• Mobile Home Certified • Ultra Low NOx • Complies with South Coast • Tankless Rack System™ Compatible Air Quality Management • 1/2 in. (13 mm) Gas Line Compatible
Sliding Mounting Bracket for Easy Installation Simple Gas Conversion
District 14 ng/J or 20 ppm NOx Emission Levels
Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
in. (mm)
Electrical
SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level
RU199i RU180i RU160i RU130i 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm)
FRONT
15,000 199,000
180,000
160,000
130,000
0.26 - 9.8 GPM 0.26 - 9.0 GPM 0.26 - 8.0 GPM 0.26 - 6.6 GPM (1.0 - 37 L/min) (1.0 - 34 L/min) (1.0 - 30 L/min) (1.0 - 24 L/min) 11 GPM 10 GPM 9 GPM 7 GPM (42 L/min) (38 L/min) (34 L/min) (26 L/min) 64 lb (29 kg) 64 lb (29 kg) 62 lb (28 kg) 62 lb (28 kg) 48 dB 47 dB 47 dB 47 dB
Normal Standby
84 W
65 W
52 W
38 W
1.3 W
Freeze Protection Max Current
148 W 4 Amps
Fuse
10 Amps
• Minimum: 98° F (37° C) Default • Maximum: 120° F (49° C) Default
Temperature
SIDE
140° F (60° C) With Parameter Adjustment
By-Pass Flow Control
Electronic
Vent Connection:
Gas Supply Pressure
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
nominal PVC/
• • • •
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)
Polypropylene or
• • • • • • •
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT
2
Electronic Connections
2 in. (51 mm)
3 in./5 in.
Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)
Water Supply Pressure Controller Cable Service Connections
Clearances
Concentric.
• Back: 0 in. • Sides: 2 in. (51 mm)*** • Vent: 0 in.
Top: 2 in. (51 mm)* Bottom/Ground: 12 in. (305 mm) Front: 0 in.**
* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box
BOTTOM
1
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
Connection COLD HOT GAS 0
25
50
75
100
125
150
PRV
F C H B E D G A
in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type
External (Outdoor) Residential Applications. Manufactured (Mobile) Home Certified
Model Numbers
RU199e (REU-N3237W-US) RU180e (REU-N2934W-US) RU160e (REU-N2530W-US) RU130e (REU-N2024W-US)
Approved Gas Types
Natural and Propane
Uniform Energy Factor (UEF)
RU199e, RU180e, RU160e: RU130e:
0.93 0.92
Energy Factor (EF) (Canada)
RU199e, RU180e, RU160e: RU130e:
0.96 0.95
High Altitude Approved
Up to 10,200 ft (3,109 m)
Water Flow Control
Water Flow Sensor, Electronic Water Control and Bypass Control
Controller
Standard: Integrated Controller Optional: MC-195T-US, MC-100V-1US, BC-100V-1US, MCC-91-2US
Certifications
AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
Warranty
• Heat Exchanger: 15 years or 12,000 operation hours, whichever • Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion
occurs first
• All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase
Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
• • • •
Tankless Water Heater Pressure Relief Valve and Adapter Isolation Valve Kit Integrated Controller
Additional Features
• Mobile Home Certified • Ultra Low NOx • Complies with South Coast • Tankless Rack System™ Compatible Air Quality Management District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line NOx Emission Levels
Compatible
● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
in. (mm)
Electrical
SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level
FRONT
RU199e RU180e RU160e RU130e 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000 199,000
180,000
160,000
0.26 - 9.8 GPM 0.26 - 9.0 GPM 0.26 - 8.0 GPM (1.0 - 37 L/min) (1.0 - 34 L/min) (1.0 - 30 L/min) 11 GPM 10 GPM 9 GPM (42 L/min) (38 L/min) (34 L/min) 64 lb (29 kg) 64 lb (29 kg) 62 lb (28 kg) 53 dB 52 dB 52 dB
Normal Standby
81 W
62 W
130,000 0.26 - 6.6 GPM (1.0 - 24 L/min) 7 GPM (26 L/min) 62 lb (28 kg) 52 dB
49 W
36 W
1.3 W
Freeze Protection Max Current
152 W 4 Amps
Fuse
10 Amps
• Minimum: 98° F (37° C) Default • Maximum: 120° F (49° C) Default
Temperature
140° F (60° C) With Parameter Adjustment
By-Pass Flow Control
Electronic
Gas Supply Pressure
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
2
Electronic Connections Water Supply Pressure Controller Cable Service Connections
Clearances
SIDE
• • • •
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)
• • • • • • •
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT
Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)
Top: 2 in. (51 mm)* • Back: 0 in. Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** Front: 0 in.** • Front Exhaust: 24 in. (610 mm)
* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box
BOTTOM
1
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
Connection COLD HOT GAS PRV 0
25
50
75
100
125
150
F C H B E D G A
in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type Model Numbers Approved Gas Types Uniform Energy Factor (UEF) Energy Factor (EF) (Canada) High Altitude Approved Water Flow Control Controller Certifications
• • • • •
Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year
Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Maximum Equivalent Vent Lengths: Twin Pipe:
Concentric:
Vent Sizes
Internal (Indoor) Residential Applications. Manufactured (Mobile) Home Certified RUR199i (REU-NP3237FF-US) RUR160i (REU-NP2530FF-US) Natural and Propane 0.93 RUR199i: 0.96 RUR160i: 0.95 Up to 10,200 ft (3,109 m) Water Flow Sensor, Electronic Water Control and Bypass Control Standard: MC-91-2US Required for Recirculation: MC-195T-US or Control-R™ Wi-Fi Module AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
2 in. (51 mm)
3 in. (76 mm)
Vent Lengths
65 ft (20 m)
150 ft (46 m)
Vent Sizes
2 in. X 4 in.
3 in. X 5 in.
Vent Lengths
65 ft (20 m)
150 ft (46 m)
Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Thermal Bypass Valve, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2) and Self-Tapping Screws (x2)
Rinnai Circ-Logic recirculation technology allows users to set recirculation patterns that coincide with their hot water usage patterns. Hot water is available when needed, without the expense of circulating it during times of inactivity. Two recirculation modes are available: • Dedicated Mode - With a dedicated return line, the integrated pump recirculates water from the tankless water heater through the return line and back to the heater. • Crossover Mode - In applications where a dedicated return line is not available or is difficult to install, ThermaCirc360® technology allows for the simple installation of a Thermal Bypass Valve (included with purchase) at the fixture farthest away from the water heater.
Additional Features • Mobile Home Certified • Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels
• Ultra Low NOx • Tankless Rack System™ Compatible • 1/2 in. (13 mm) Gas Line Compatible
Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
Thermal Bypass Valve
• • • •
Compact Design to Save Space Wi-Fi Technology for Remote Monitoring and Management Sliding Mounting Bracket for Easy Installation Simple Gas Conversion
● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
in. (mm)
Electrical
SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level
FRONT
RUR199i RUR160i 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000 199,000
160,000
0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 73 lb (33 kg) 49 dB
0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 71 lb (32 kg) 48 dB
Normal Standby
84 W
52 W 1.3 W
Freeze Protection Max Current
160 W 4 Amps
Fuse
10 Amps
• Minimum:
98° F (37° C) Default 120° F (49° C) Crossover Mode • Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment Electronic
Temperature By-Pass Flow Control
SIDE Vent Connection:
Gas Supply Pressure
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
nominal PVC/
• Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital) • Minimum: 50 PSI (Recommended 60-80 PSI for max
Polypropylene or
2
Electronic Connections Water Supply Pressure
2 in. (51 mm)
3 in./5 in. Concentric.
performance) • Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)
Controller Cable
• • • • • • •
Service Connections
Clearances
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT Top: 2 in. (51 mm)* • Back: 0 in. Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** Front: 0 in.** • Vent: 0 in.
* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box 1 2
BOTTOM
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
Connection COLD HOT GAS 0
25
50
75
100
125
150
PRV
F C H B E D G A
in. mm 9.27 235 3.11 79 14.49 368 6.52 166 3.57 91 2.79 71 10.40 264 7.60 193
35 Pump Performance Curve
30
Pump and Tankless Performance Curve @140°F Set
20 15
(5.30 GPM)
10 (1.05 GPM)
Head - Feet
25
5
0 0
1
2
3 Flow Rate (GPM)
4
5
The RUR pump has an operation range of 1.05 GPM to 5.30 GPM
Internal Recirculation Pump Control
Built-in Rinnai Circ-Logic: Recirculation program cycles internal pump
Internal Pump
Integrated pump and bypass technology allow for recirculation through a dedicated return line or thermal bypass valve.
Maximum Recirculation Pipe Lengths
• •
400 equivalent feet for 3/4 in. pipe diameter 100 equivalent feet for 1/2 in. pipe diameter Take equivalent elbow lengths into consideration when calculating pipe length. For dedicated return lines: Total length includes both hot water supply and dedicated return lines. Cross-over mode: Total length includes both hot water supply and cold water piping length from the tankless water heater to the thermal bypass valve. Cross-over mode requires the use of a thermal bypass valve (included).
6
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER
Rinnai Circ-Logic recirculation technology allows users to set recirculation patterns that coincide with their hot water usage patterns. Hot water is available when needed, without the expense of circulating it during times of inactivity. Two recirculation modes are available: • Dedicated Mode - With a dedicated return line, the integrated pump recirculates water from the tankless water heater through the return line and back to the heater. • Crossover Mode - In applications where a dedicated return line is not available or is difficult to install, ThermaCirc360® technology allows for the simple installation of a Thermal Bypass Valve (included with purchase) at the fixture farthest away from the water heater. Thermal Bypass Valve
Installation Type
External (Outdoor) Residential Applications
Model Numbers
RUR199e (REU-NP3237W-US) RUR160e (REU-NP2530W-US)
Approved Gas Types
Natural and Propane
Uniform Energy Factor (UEF)
0.93
Energy Factor (EF) (Canada)
0.96
High Altitude Approved
Up to 10,200 ft (3,109 m)
Water Flow Control
Water Flow Sensor, Electronic Water Control and Bypass Control
Controller
Standard: MC-91-2US Required for Recirculation: MC-195T-US or Control-R™ Wi-Fi Module
Certifications
AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Thermal Bypass Valve, Pressure Relief Valve and Adapter, Isolation Valve Kit, Integrated Controller, and Recirculation Pump Cable Additional Features
• Complies with South Coast • Ultra Low NOx Air Quality Management • Tankless Rack System™ Compatible District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels
Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
• Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion
●
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
in. (mm)
Electrical
SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level
FRONT
RUR199e RUR160e 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000 199,000
160,000
0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 73 lb (33 kg) 53 dB
0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 71 lb (32 kg) 52 dB
81 W
49 W
Normal Standby Freeze Protection Max Current
1.3 W 198 W 4 Amps
Fuse
10 Amps
• Minimum: Temperature By-Pass Flow Control
98° F (37° C) Default 120° F (49° C) Crossover Mode • Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment Electronic
Gas Supply Pressure2
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
Electronic Connections Water Supply Pressure Controller Cable Service Connections
Clearances
SIDE
• • • •
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)
• • • • • • •
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT Top: 2 in. (51 mm)* • Back: 0 in. Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** Front: 0 in.** • Front Exhaust: 24 in. (610 mm)
Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)
* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box 1 2
BOTTOM
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
Connection COLD HOT GAS 0
25
50
75
100
125
150
PRV
F C H B E D G A
in. mm 9.27 235 3.11 79 14.49 368 6.52 166 3.57 91 2.79 71 10.40 264 7.60 193
35 Pump Performance Curve
30
Pump and Tankless Performance Curve @140°F Set
20 15
(5.30 GPM)
10 (1.05 GPM)
Head - Feet
25
5
0 0
1
2
3 Flow Rate (GPM)
4
5
The RUR pump has an operation range of 1.05 GPM to 5.30 GPM
Internal Recirculation Pump Control
Built-in Rinnai Circ-Logic: Recirculation program cycles internal pump
Internal Pump
Integrated pump and bypass technology allow for recirculation through a dedicated return line or thermal bypass valve.
Maximum Recirculation Pipe Lengths
• •
400 equivalent feet for 3/4 in. pipe diameter 100 equivalent feet for 1/2 in. pipe diameter Take equivalent elbow lengths into consideration when calculating pipe length. For dedicated return lines: Total length includes both hot water supply and dedicated return lines. Cross-over mode: Total length includes both hot water supply and cold water piping length from the tankless water heater to the thermal bypass valve. Cross-over mode requires the use of a thermal bypass valve (included).
6
RL75i (VC2528FFUD-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
Rinnai Model Number
REU-VC2528FFUD-US
Operation / Installation
Forced combustion; indoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 180,000 BTU/h
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 76 w
Amperage
Max with pump: 8A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
Temperature
98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with MCC-91-2 controller for hydronic applications
Temperature (without remote)
120° F (49° C) (factory default) or 140° F (60° C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Isolation & Pressure Relief Valves Included
Isolation Valves are certified to NSF/ANSI 61 for potable water
Water Flow Control
Water flow sensor, electronic water control device and fixed by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w
Anti-frost protection: 120 w
Max without pump: 4A
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
Hot Water Flow Rate (gpm)
8.0 (30.3) 8.0
FLOW TABLE
7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0
00
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
125(69.4)
100
150(83.3)
125
150
RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature
© 2017 Rinnai Corporation
RL75i VC SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
SANITATION
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
RL75i (VC2528FFUD-US) External Recirculation Pump Control
Rinnai Circ-Logic™: Recirculation program cycles external pump
Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Top of heater - 6 inches(152mm) Back of heater - 0 inches Front of heater - 6 inches(152mm)* Ground / bottom - 12 inches(305mm) Sides of heater - 2 inches(51mm) From vent pipe - 0 inches
Clearances from Non-combustibles
Top of heater - 2 inches(51mm) Back of heater - 0 inches Front of heater - 6 inches(152mm)* Ground / bottom - 12 inches(305mm) Sides of heater - 1/2 inch(13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure (sea level)
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.2” W.C. (5.5mbar) low fire 0.61” W.C. (1.5mbar) Propane Gas: high fire 3.8” W.C. (9.5mbar) low fire 0.87” W.C. (2.2mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS 14.04 (356.6)
WEIGHT: 45.6 lb (20.7 kg) 9.27 (235.5)
0.4~1.8 (10~45) Variable 2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D DIMENSION Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
A
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
RL75e (VC2528WD-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion
Rinnai Model Number
REU-VC2528WD-US
Operation / Installation
Forced combustion; outdoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 180,000 BTU/h
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 57 w
Amperage
Max with pump: 8A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)
Temperature
98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with the MCC-91-2 controller for commercial and hydronic applications
Temperature (without remote)
120° F (49° C) (factory default) or 140° F (60° C)
Installation
Outdoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Isolation & Pressure Relief Valves Included
Isolation Valves are certified to NSF/ANSI 61 for potable water
Water Flow Control
Water flow sensor, electronic water control device and fixed by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w
Anti-frost protection: 104 w
Max without pump: 4A
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
Hot Water Flow Rate (gpm)
8.0 (30.3) 8.0
FLOW TABLE
7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0
00
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
125(69.4)
100
150(83.3)
125
150
RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature
© 2017 Rinnai Corporation
RL75e VC SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
SANITATION
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
RL75e (VC2528WD-US) External Recirculation Pump Control
Rinnai Circ-Logic™: Recirculation program cycles external pump
Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 12 inches(305mm) Back of heater - 0 inches Bottom of heater - 12 inches(305mm) Front (Panel) - 24 inches(610mm) Front (Exhaust) - 24 inches(610mm) Sides of heater - 6 inches(152mm)
Clearances from Non-combustibles
Back of heater - 0 inches Top of heater - 2 inches(51mm) Bottom of heater - 2 inches(51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches(610mm) Sides of heater - 1/8 inch(3.2mm)
*24 inches required for serviceability
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.) (sea level)
Natural Gas: high fire 2.0” W.C. (5.0mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 3.5” W.C. (8.7mbar) low fire 0.80” W.C. (2.00mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS 14.04 (356.6)
WEIGHT: 43.6 lb (19.8 kg) 2.23 (56.6)
Limited Warranty
0.28 (7.2)
9.27 (235.5)
0.59 (15)
8.90 (226)
C
F G
E D
22.95 (583)
1.14 (29)
B
DIMENSION Inches (mm)
A
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.91 (73.8)
A (HOT)
1.35 (34.4)
F
1.61 (40.8)
B
3.96 (100.7)
G
2.87 (73)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
RL94i (VC2837FFUD-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
Rinnai Model Number
REU-VC2837FFUD-US
Operation / Installation
Forced combustion; indoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 199,000 BTU/h
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 97 w
Amperage
Max with pump: 8A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)
Temperature
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications
Temperature (without remote)
120°F (49°C) (factory default) or 140°F (60°C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Isolation & Pressure Relief Valves Included
Isolation Valves are certified to NSF/ANSI 61 for potable water
Water Flow Control
Water flow sensor, electronic water control device and by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w
Anti-frost protection: 120 w
Max without pump: 4A
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE
10.0 (37.9) 10.0
Water Flow gpm (l/min)
9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0
0
0
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
100
125(69.4)
125
150(83.3)
150
delta T - Temperature Rise (ºF) © 2017 Rinnai
RL94i VC SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
RL94i (VC2837FFUD-US) External Recirculation Pump Control
Rinnai Circ-Logic™(Included): Recirculation program cycles external pump
Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Top of heater - 6 inches (152mm) Back of heater - 0 inches Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 2 inches (51mm) From vent pipe - 0 inches
Clearances from Non-combustibles
Top of heater - 2 inches (51mm) Back of heater - 0 inches Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 1/2 inch (13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure (sea level)
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.9” W.C. (7.22mbar) low fire 0.61” W.C. (1.52mbar) Propane Gas: high fire 4.7” W.C. (11.71mbar) low fire 0.87” W.C. (2.17mbar)
NOx
Complies with South Coast Air Quality Management District 40 ng/J or 55 ppm NOx emission levels
Limited Warranty
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS 14.04 (356.6)
WEIGHT: 46.3 lb (21.0 kg) 9.27 (235.5)
0.4~1.8 (10~45) Variable 2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D
A
DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
RLX94i (VC2737FFUD-US) Nat. Gas Unit Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
Rinnai Model Number
REU-VC2737FFUD-US
Minimum/Maximum Gas Rate (Input)
10,300 - 192,000 BTU/h (3.02-56.3kWh)
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 97 w
Amperage
Max with pump: 8A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)
Temperature
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications
Temperature (without remote)
120°F (49°C) (factory default) or 140°F (60°C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT
Isolation & Pressure Relief Valves Included
Isolation Valves are certified to NSF/ANSI 61 for potable water
Water Flow Control
Water flow sensor, electronic water control device and by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w
Anti-frost protection: 120 w
Max without pump: 4A
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
FLOW TABLE
(37.9) 10.0 10.0 (34.1) 9.09.0 (30.3) 8.08.0 (26.5) 7.07.0 (22.7) 6.06.0 (19.0) 5.05.0 (15.1) 4.04.0 (11.4) 3.03.0 (7.6) 2.02.0 (3.8) 1.01.0
0.0 0.0
0
25
50
(13.9)
(27.8)
25
50
75 75
(41.6)
100 100 (55.6)
150
125 125 (69.4)
150 (83.3)
delta T - Temperature Rise ºF (ºC)
© 2017 Rinnai Corporation
RLX94i VC SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
RLX94i (VC2737FFUD-US) Nat. Gas Unit External Recirculation Pump Control Water Temperature Control
Rinnai Circ-Logic™(Included): Recirculation program cycles external pump
Simulation feed forward and feedback
Controller
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Top of heater - 6 inches (152mm) Back of heater - 0 inches Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 2 inches (51mm) From vent pipe - 0 inches
Clearances from Non-combustibles
Back of heater - 0 inches Top of heater - 2 inches (51mm) Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 1/2 inch (13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure (sea level)
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.93” W.C. (7.3mbar) Low fire 0.61” W.C. (1.5mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Remaining flame (OHS) Thermal fuse Automatic frost protection
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS 14.04 (356.6)
WEIGHT: 46.3 lb (21.0 kg) 9.27 (235.5)
0.4~1.8 (10~45) Variable 2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D DIMENSION Inches (mm)
A
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
RL94e (VC2837WD-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion
Rinnai Model Number
REU-VC2837WD-US
Operation / Installation
Forced combustion; outdoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 199,000 BTU/h
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 65 w
Amperage
Max with pump: 8A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)
Temperature
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications
Temperature (without remote)
120°F (49°C) (factory default) or 140°F (60°C)
Installation
Outdoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Isolation & Pressure Relief Valves Included
Isolation Valves are certified to NSF/ANSI 61 for potable water
Water Flow Control
Water flow sensor, electronic water control device and by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w
Anti-frost protection: 104 w
Max without pump: 4A
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE
10.0 (37.9) 10.0
Water Flow gpm (l/min)
9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0
0
0
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
100
125(69.4)
125
150(83.3)
150
delta T - Temperature Rise (ºF) © 2017 Rinnai Corporation
RL94e VC SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
RL94e (VC2837WD-US) External Recirculation Pump Control
Rinnai Circ-Logic™(Included): Recirculation program cycles external pump
Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 12 inches(305mm) Back of heater - 0 inches Bottom of heater - 12 inches(305mm) Front (Panel) - 24 inches(610mm) Front (Exhaust) - 24 inches(610mm) Sides of heater - 6 inches(152mm)
Clearances from Non-combustibles
Top of heater - 2 inches(51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches(610mm)
* 24 inches required for serviceability
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Back of heater - 0 inches Bottom of heater - 2 inches(51mm) Sides of heater - 1/8 inch(3.2mm)
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.) (sea level)
Natural Gas: high fire 2.5” W.C. (6.23mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 4.5” W.C. (11.21mbar) low fire 0.80” W.C. (2.00mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS 14.04 (356.6)
WEIGHT: 44.3 lb (20.1 kg) 2.23 (56.6)
Limited Warranty
0.28 (7.2)
9.27 (235.5)
0.59 (15)
8.90 (226)
C
F G
E D
22.95 (583)
1.14 (29)
B
A
DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.91 (73.8)
A (HOT)
1.35 (34.4)
F
1.61 (40.8)
B
3.96 (100.7)
G
2.87 (73)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
HIGH-EFFICIENCY (NON-CONDENSING) TANKLESS WATER HEATER Installation Type
External (Outdoor) Residential Applications. Manufactured (Mobile) Home Certified
Model Number
V53De (REU-AM1620WD-US)
Approved Gas Types
Natural and Propane
Water Flow Control
Water Flow Sensor, Electronic Water Control and Fixed Bypass
Water Temperature Control Simulation Feed Forward and Feedback Ignition System
Direct Electronic Ignition
Controller
Standard: Status Monitor Optional: MC-601, MC-91-2US Certifications AHRI, ANSI Z21.10.3, CSA 4.3 Uniform Energy Factor (UEF) 0.81 High Altitude Approved
Up to 10,200 Ft (3,109 M)
Minimum Gas Consumption 15,500 Btu/h Maximum Gas Consumption 120,000 Btu/h
To Non-Combustibles in. (mm)
Top
12 (305)
2 (51)
Back
0 (zero)
0 (zero)
Front (Panel)
24 (610)
0 (zero)
Front (Exhaust)
24 (610)
24 (610)
Sides
6 (152)
1/8 (3.2)
Bottom
12 (305)
2 (51)
0.4 - 5.3 GPM (1.5 - 20.0 L/min)
Dimensions - w, h, d
14.0 in. x 19.8 in. x 7.9 in. (356 mm x 503 mm x 202 mm) 29.7 lb (13.5 kg)
Weight Sound Level Normal Standby Freeze Protection
Electrical
To Combustibles in. (mm)
Flow Rate1 (Min - Max)
50 W 2W 64 W
Max Current
1.2 Amps
Fuse
5 Amps
• Minimum: 115° F (46° C) Default • Maximum: 140° F (60° C) Default
Temperature
Without Temperature Controller: 120° F (49° C) Default or 140° F (60° C) Bypass Flow Control
The clearance for servicing is 24 in. (610 mm) in front of the water heater.
Gas Supply Pressure
Fixed 2
Electronic Connections
•
54 dB
• • • •
Natural: 4.5 in. w.c. - 10.5 in. w.c. Propane: 8.0 in. w.c. - 13.5 in. w.c. Appliance: AC 120 Volts, 60Hz. Temp. Controller: DC 12 Volts (Digital)
• Minimum: 20 PSI (Recommended
Safety Devices: Flame Failure -Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current-Glass Fuse, Remaining Flame (OHS), Automatic Frost Protection, and Thermal Fuse
Water Supply Pressure
• •
Gas Line Compatible: 1/2 in. (13 mm)
Controller Cable
Complies with South Coast Air Quality Management District 40 ng/J NOx Emission Levels
Non-Polarized Two Core Cable (Minimum 22 AWG)
Service Connections
•
Included with Purchase: V53De Tankless Water Heater and Wall Mounting Bracket
• Gas Supply: 3/4 in. (19 mm) MNPT • Cold Water Inlet: 3/4 in. (19 mm) MNPT • Hot Water Outlet: 3/4 in. (19 mm) MNPT
●
30-80 PSI for max performance)
• Maximum: 150 PSI
1
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.6 GPM (1.5 L/min).
2
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
in. (mm) A
Width
14.0 (356)
B
Depth
7.9 (202)
C
Height (Unit)
19.8 (503)
D
Height (With Brackets)
22.5 (571)
E
Hot Water Outlet From Wall
3.4 (87)
F
Hot Water Outlet From Center
4.1 (105)
G
Cold Water Inlet From wall
2.7 (68)
H
Cold Water Inlet From Center
0.4 (10)
I
Gas Connection From wall
3.0 (77)
J
Gas Connection From Center
3.3 (83)
K
From Base to Gas Connection
1.6 (40)
From Base to Cold Connection
2.0 (50)
From Base to Hot Connection
1.5 (39)
6.0
Water Flow (GPM)
5.0
4.0
3.0
2.0
1.0
0.0
0
25
50
75
100
Delta T - Temperature Rise (°F)
125
150
V65i (VC2025FFU-US) Type of Appliance
• • •
Rinnai Model Number
REU-VC2025FFU-US
Operation/Installation
Forced combustion; indoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 150,000 BTU/h (3.0-44.0 kWh)
Electrical
• •
Electrical Consumption
Normal: 76 w
Standby: 2 w
Amperage
Max: 4A
Fuse: 10A
Ignition System
Direct Electronic Ignition
Hot Water Capacity
• • •
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
Temperature
• • •
98°-120° F (37°- 49° C) (factory default) Maximum temperature is selectable at 120° F (49° C) or at 140° F (60° C) 98°-160° F (37°-71° C) available with the MCC-91-2 controller for hydronic applications
Temperature (without remote)
120° F (49° C) (factory default) or 140° F (60° C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.80
Service Connections
• • •
Water Flow Control
Water flow sensor, electronic water control device and fixed bypass
Minimum/Maximum Water Supply Pressure
• •
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced Combustion / Direct Vent
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Anti-frost protection: 120 w
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT 20-150 PSI (138-1,035 KPa) Recommend 30-80 PSI (209-552 KPa) for optimal performance
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE
Water Flow gpm (l/min)
7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0 0 0
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
125(69.4)
100
125
150(83.3)
150
delta T - Temperature Rise (ºF) © 2018 Rinnai
V65i SP(03)
6/2018 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
V65i (VC2025FFU-US) Water Temperature Control
Simulation feed forward and feedback
Controller
• • • •
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
• • • •
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
• • •
• Top of heater - 6 inches (152 mm) Front of heater - 6 inches (152 mm)* • Sides of heater - 2 inches (51 mm) •
Back of heater - 0 inches Ground / bottom - 12 inches (305 mm) From vent pipe - 0 inches
Clearances from Non-combustibles
• Top of heater - 2 inches (51 mm) • • Front of heater - 6 inches (152 mm)* • • Sides of heater - 1/2 inch (13 mm) • * 24 inches required for serviceability
Back of heater - 0 inches Ground / bottom - 12 inches (305 mm) From vent pipe - 0 inches
Min/Max Gas Supply Pressure
• •
Natural Gas: Min: 4” W.C. (10 mbar) Propane Gas: Min: 8” W.C. (20 mbar)
Max: 10.5” W.C. (26.1 mbar) Max: 13.5” W.C. (33.6 mbar)
Manifold Gas Pressure (inches W.C.)
• •
Natural Gas: High Fire: 1.8” W.C. (4.5 mbar) Propane Gas: High Fire: 2.8” W.C. (7.0 mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Warranty
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)
• • •
Remaining flame (OHS) Thermal fuse Automatic frost protection
Low Fire: 0.61” W.C. (1.5 mbar) Low Fire: 0.87” W.C. (2.2 mbar)
Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
DIMENSIONS 14.04 (356.6)
WEIGHT: 45.6 lb (20.7 kg) 9.27 (235.5)
0.4~1.8(10~45) Variable
2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D
A
DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
V65e (VC2025W-US) Type of Appliance
• • •
Rinnai Model Number
REU-VC2025W-US
Operation/Installation
Forced combustion; outdoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 150,000 BTU/h (3.0-44.0 kWh)
Electrical
• •
Electrical Consumption
Normal: 57 w
Standby: 2 w
Amperage
Max: 4A
Fuse: 10A
Ignition System
Direct Electronic Ignition
Hot Water Capacity
• • •
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
Temperature
• • •
98°-120° F (37°- 49° C) (factory default) Maximum temperature is selectable at 120° F (49° C) or at 140° F (60° C) 98°-160° F (37°-71° C) available with the MCC-91-2 controller for hydronic applications
Temperature (without remote)
120° F (49° C) (factory default) or 140° F (60° C)
Installation
Outdoor only
Uniform Energy Factor (UEF)
0.79
Service Connections
• • •
Water Flow Control
Water flow sensor, electronic water control device and fixed bypass
Minimum/Maximum Water Supply Pressure
• •
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Anti-frost protection: 104 w
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT 20-150 PSI (138-1,035 KPa) Recommend 30-80 PSI (209-552 KPa) for optimal performance
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. 7.0 (26.5) 7.0
Water Flow gpm (l/min)
FLOW TABLE
6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0 0 0
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
125(69.4)
100
125
150(83.3)
150
delta T - Temperature Rise (ºF) © 2018 Rinnai Corporation
V65e SP(03)
6/2018 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
V65e (VC2025W-US) Water Temperature Control
Simulation feed forward and feedback
Controller
• • • •
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
• • • •
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Clearances from Combustibles
• • •
Top of heater - 12 inches (305 mm) Front (Panel) - 24 inches (610 mm) Front (Exhaust) - 24 inches (610 mm)
• • •
Back of heater - 0 inches Bottom of heater - 12 inches (305 mm) Sides of heater - 6 inches (152 mm)
Clearances from Non-combustibles
• • •
Top of heater - 2 inches (51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches (610 mm)
• • •
Back of heater - 0 inches Bottom of heater - 2 inches (51 mm) Sides of heater - 1/8 inch (3.2 mm)
MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)
• • •
Remaining flame (OHS) Thermal fuse Automatic frost protection
* 24 inches required for serviceability Min/Max Gas Supply Pressure
• •
Natural Gas: Min: 4” W.C. (10 mbar) Propane Gas: Min: 8” W.C. (20 mbar)
Manifold Gas Pressure (inches W.C.)
• •
Natural Gas: High fire 1.30” W.C. (3.24 mbar) Propane Gas: High fire 2.45” W.C. (6.10 mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Low fire 0.52” W.C. (1.30 mbar) Low fire 0.80” W.C. (2.00 mbar)
Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year; (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
DIMENSIONS 14.04 (356.6)
WEIGHT: 43.6 lb (19.8 kg) 2.23 (56.6)
Warranty
Max: 10.5” W.C. (26.1 mbar) Max:13.5” W.C. (33.6 mbar)
0.28 (7.2)
9.27 (235.5)
0.59 (15)
8.90 (226)
C
F G
E D
22.95 (583)
1.14 (29)
B
DIMENSION Inches (mm)
A
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.91 (73.8)
A (HOT)
1.35 (34.4)
F
1.61 (40.8)
B
3.96 (100.7)
G
2.87 (73)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
V75i (VC2528FFU-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
Rinnai Model Number
REU-VC2528FFU-US
Operation / Installation
Forced combustion; indoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 180,000 BTU/h
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 76 w
Standby: 2 w
Amperage
Max: 4A
Fuse: 10A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)
Temperature
98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with MCC-91-2 controller for hydronic applications
Temperature (without remote)
120° F (49° C) (factory default) or 140° F (60° C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water Flow Control
Water flow sensor, electronic water control device and fixed by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Anti-frost protection: 120 w
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
Hot Water Flow Rate (gpm)
8.0 (30.3) 8.0
FLOW TABLE
7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0
00
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
125(69.4)
100
125
150(83.3)
150
RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature
© 2017 Rinnai Corporation
V75i SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
V75i (VC2528FFU-US) Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Top of heater - 6 inches(152mm) Back of heater - 0 inches Front of heater - 6 inches(152mm)* Ground / bottom - 12 inches(305mm) Sides of heater - 2 inches(51mm) From vent pipe - 0 inches
Clearances from Non-combustibles * 24 inches required for serviceability
Top of heater - 2 inches(51mm) Back of heater - 0 inches Front of heater - 6 inches(152mm)* Ground / bottom - 12 inches(305mm) Sides of heater - 1/2 inch(13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.2” W.C. (5.5mbar) low fire 0.61” W.C. (1.5mbar) Propane Gas: high fire 3.8” W.C. (9.5mbar) low fire 0.87” W.C. (2.2mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.
DIMENSIONS 14.04 (356.6)
WEIGHT: 45.6 lb (20.7 kg) 9.27 (235.5)
0.4~1.8 (10~45) Variable 2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
A
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
V75e (VC2528W-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion
Rinnai Model Number
REU-VC2528W-US
Operation / Installation
Forced combustion; outdoor only;
Minimum/Maximum Gas Rate (Input)
10,300 - 180,000 BTU/h
Electrical
Appliance: Controller:
Electrical Consumption
Normal: 57 w
Standby: 2 w
Amperage
Max: 4A
Fuse: 10A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)
Temperature
98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with MCC-91-2 controller for hydronic applications
Temperature (without remote)
120° F (49° C) (factory default) or 140° F (60° C)
Installation
Outdoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water Flow Control
Water flow sensor, electronic water control device and fixed by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa for optimal performance)
AC 120 Volts - 60 Hz DC 12 Volts Anti-frost protection: 104 w
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
Hot Water Flow Rate (gpm)
8.0 (30.3) 8.0
FLOW TABLE
7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0
00
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
125(69.4)
100
125
150(83.3)
150
RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature
© 2017 Rinnai Corporation
V75e SP(02)
5/2017 C
U
Low Lead Content NSF/ANSI 372
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SANITATION
V75e (VC2528W-US) Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 12 inches(305mm) Front (Panel) - 24 inches(610mm) Front (Exhaust) - 24 inches(610mm)
Back of heater - 0 inches Bottom of heater - 12 inches(305mm) Sides of heater - 6 inches(152mm)
Clearances from Non-combustibles
Top of heater - 2 inches(51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches(610mm)
Back of heater - 0 inches Bottom of heater - 2 inches(51mm) Sides of heater - 1/8 inch(3.2mm)
* 24 inches required for serviceability Min. / Max. Gas Supply Pressure
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.0” W.C. (5.0mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 3.5” W.C. (8.7mbar) low fire 0.80” W.C. (2.00mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.
DIMENSIONS
WEIGHT: 43.6 lb (19.8 kg)
14.04 (356.6)
2.23 (56.6)
Limited Warranty
0.28 (7.2)
9.27 (235.5)
0.59 (15)
8.90 (226)
C
F G
E D
22.95 (583)
1.14 (29)
B
A
DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.91 (73.8)
A (HOT)
1.35 (34.4)
F
1.61 (40.8)
B
3.96 (100.7)
G
2.87 (73)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
V94i (VC2837FFU-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
Rinnai Model Number
REU-VC2837FFU-US
Operation / Installation
Forced combustion; indoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 199,000 BTU/h (3.02-58.3kWh)
Electrical
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts
Electrical Consumption
Normal: 97 w
Amperage
Max : 4A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)
Temperature
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for hydronic applications
Temperature (without remote)
120°F (49°C) (factory default) or 140°F (60°C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control device and by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
Standby: 2 w
Anti-frost protection: 120 w
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE
10.0 (37.9) 10.0
Water Flow gpm (l/min)
9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8)
0.00.0
0
0
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
100
125(69.4)
125
150(83.3)
150
delta T - Temperature Rise (ºF) © 2017 Rinnai
V94i VC SP-01
5/2017 C
U
Low Lead Content NSF/ANSI 372
SANITATION
V94i (VC2837FFU-US) Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Top of heater - 6 inches (152mm) Back of heater - 0 inches Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 2 inches (51mm) From vent pipe - 0 inches
Clearances from Non-combustibles
Top of heater - 2 inches (51mm) Back of heater - 0 inches Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 1/2 inch (13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure (sea level)
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.9” W.C. (7.22mbar) low fire 0.61” W.C. (1.52mbar) Propane Gas: high fire 4.7” W.C. (11.71mbar) low fire 0.87” W.C. (2.17mbar)
NOx
Complies with South Coast Air Quality Management District 40 ng/J or 55 ppm NOx emission levels
Limited Warranty
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.
DIMENSIONS
WEIGHT: 46.3 lb (21.0 kg) 9.27 (235.5)
14.04 (356.6)
0.4~1.8 (10~45) Variable 2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D
A
DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
V94Xi (VC2737FFU-US) Nat. Gas Unit Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion / Direct vent
Rinnai Model Number
REU-VC2737FFU-US
Minimum/Maximum Gas Rate (Input)
10,300 - 192,000 BTU/h (3.02-56.3kWh)
Electrical
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts
Electrical Consumption
Normal: 97 w
Amperage
Max : 4A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)
Temperature
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for hydronic applications
Temperature (without remote)
120°F (49°C) (factory default) or 140°F (60°C)
Installation
Indoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control device and by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
Standby: 2 w
Anti-frost protection: 120 w
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Water Flow gpm (l/min)
FLOW TABLE
(37.9) 10.0 10.0 (34.1) 9.09.0 (30.3) 8.08.0 (26.5) 7.07.0 (22.7) 6.06.0 (19.0) 5.05.0 (15.1) 4.04.0 (11.4) 3.03.0 (7.6) 2.02.0 (3.8) 1.01.0
0.0 0.0
0
25
50
(13.9)
(27.8)
25
50
75 75
(41.6)
100 100 (55.6)
150
125 125 (69.4)
150 (83.3)
delta T - Temperature Rise ºF (ºC)
© 2017 Rinnai Corporation
V94Xi VC SP-01
5/2017 C
U
Low Lead Content NSF/ANSI 372
SANITATION
V94Xi (VC2737FFU-US) Nat. Gas Unit Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Top of heater - 6 inches (152mm) Back of heater - 0 inches Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 2 inches (51mm) From vent pipe - 0 inches
Clearances from Non-combustibles
Back of heater - 0 inches Top of heater - 2 inches (51mm) Front of heater - 6 inches (152mm) Ground / bottom - 12 inches (305mm) Sides of heater - 1/2 inch (13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure (sea level)
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.93” W.C. (7.3mbar) Low fire 0.61” W.C. (1.5mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Remaining flame (OHS) Thermal fuse Automatic frost protection
Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information. WEIGHT: 46.3 lb (21.0 kg)
DIMENSIONS
9.27 (235.5)
14.04 (356.6)
0.4~1.8 (10~45) Variable 2.67 (67.8)
5.05 (128.1)
B
C
E
F G
22.95 (583)
D DIMENSION Inches (mm)
A
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.89 (73.3)
A (HOT)
1.35 (34.4)
F
1.85 (47)
B
4.21 (106.9)
G
3.44 (87.3)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
V94e (VC2837W-US) Type of Appliance
Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion
Rinnai Model Number
REU-VC2837W-US
Operation / Installation
Forced combustion; outdoor only
Minimum/Maximum Gas Rate (Input)
10,300 - 199,000 BTU/h (3.02-58.3kWh)
Electrical
Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts
Electrical Consumption
Normal: 65 w
Amperage
Max : 4A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)
Temperature
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for hydronic applications
Temperature (without remote)
120°F (49°C) (factory default) or 140°F (60°C)
Installation
Outdoor only
Uniform Energy Factor (UEF)
0.81
Service Connections
Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control device and by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)
Standby: 2 w
Anti-frost protection: 104 w
Fuse: 10A
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE
10.0 (37.9) 10.0
Water Flow gpm (l/min)
9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0
0
0
25(13.9)
25
50(27.8)
50
75(41.6)
75
100(55.6)
100
125(69.4)
125
150(83.3)
150
delta T - Temperature Rise (ºF) © 2017 Rinnai Corporation
V94e VC SP-01
5/2017 C
U
Low Lead Content NSF/ANSI 372
SANITATION
V94e (VC2837W-US) Water Temperature Control
Simulation feed forward and feedback
Controller
MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 12 inches(305mm) Back of heater - 0 inches Bottom of heater - 12 inches(305mm) Front (Panel) - 24 inches(610mm) Front (Exhaust) - 24 inches(610mm) Sides of heater - 6 inches(152mm)
Clearances from Non-combustibles
Top of heater - 2 inches(51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches(610mm)
* 24 inches required for serviceability
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Back of heater - 0 inches Bottom of heater - 2 inches(51mm) Sides of heater - 1/8 inch(3.2mm)
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.) (sea level)
Natural Gas: high fire 2.5” W.C. (6.23mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 4.5” W.C. (11.21mbar) low fire 0.80” W.C. (2.00mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.
DIMENSIONS
WEIGHT: 44.3 lb (20.1 kg)
14.04 (356.6)
2.23 (56.6)
Limited Warranty
0.28 (7.2)
9.27 (235.5)
0.59 (15)
8.90 (226)
C
F G
E D
22.95 (583)
1.14 (29)
B
A
DIMENSION
Inches (mm)
DIMENSION
Inches (mm)
A (GAS)
1.31 (33.2)
D
4.33 (110)
A (COLD)
1.93 (49)
E
2.91 (73.8)
A (HOT)
1.35 (34.4)
F
1.61 (40.8)
B
3.96 (100.7)
G
2.87 (73)
C
1.17 (29.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
RUCS65i (KCM2025FFU) Type of Appliance
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified
Rinnai model number
REU-KCM2025FFU-US
Operation / Installation
Forced combustion; indoor only; Certified for installation in Manufactured (Mobile) Homes
Minimum/Maximum Gas Rate (Input)
10,300 - 130,000 BTU/h
Electrical
Appliance: Temperature Controller:
Electrical Consumption
Normal: 89 w
Standby: 1.3 w Anti-frost protection: 167 w
Amperage
Max: 2.3A
Fuse: 10A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
Temperature (with remote)
120° - 140° F (49°- 60°C)
Temperature (without remote)
120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)
Approved Gas Types
Natural or Propane (ensure unit matches gas type)
Uniform Energy Factor (UEF)
0.90
Service Connections
Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control and fixed by-pass
Minimum/Maximum Water Supply Pressure
50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)
High Altitude Capability
Up to 5,400 ft (1646 m) elevation above sea level
AC 120 Volts - 60 Hz DC 12 Volts
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
10.0 (37.9)
Water Flow gpm (l/min)
9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0
25 (13.9) 50 (27.8) 75 (41.6) delta T - Temperature Rise ºF (ºC) © 2017 Rinnai Corporation
RUCS65i-SP-2
100 (55.6)
5/2017 C
US
Low Lead Content NSF/ANSI 372
SANITATION
125 (69.4)
150 (83.3)
RUCS65i (KCM2025FFU) Controller (Optional)
MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 6 inches (152mm) Back of heater - 0 inches Front of heater - 6 inches *(152mm) Bottom of heater - 12 inches (305mm) Sides of heater - 2 inches (51mm) From vent pipe - 0 inches
* 24 inches (610mm) required for service Clearances from Non-combustibles * 24 inches (610mm) required for service
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Top of heater - 2 inches (51mm) Back of heater - 0 inches Front of heater - 6 inches *(152mm) Bottom of heater - 12 inches (305mm) Sides of heater - 1/2 inches (13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.27” W.C. (5.7mbar) low fire 1.00” W.C. (2.5mbar) Propane Gas: high fire 2.58” W.C. (6.4mbar) low fire 1.08” W.C. (2.7mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Venting
Direct Vent system designed for use with Ubbink Polypropylene Concentric Vent, Twin Pipe PVC/CPVC (3” and 4” configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adapter) See installation and operation manual for details regarding installation and allowed vent lengths.
Limited Warranty
Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
WEIGHT: 57.3 lb (26 kg) 10.1 (257)
ø 5.5 (140.2) 5.9 (150)
2 (50.6)
1.2 (30.7)
DIMENSIONS
D
B C
H
A
28.5 (723)
25.7 (653.2)
31.1 (789.6)
E
F
I
G J
DIM
Inches (mm)
DIM
Inches (mm)
A (GAS)
1.3 (33.2)
D
0.09 (2.2)
A (COLD)
1.93 (49)
E
5.6 (142.3)
A (HOT)
1.35 (34.4)
F
3.24 (82.4)
G
3.99 (101.4)
H
1.58 (40.1)
I
3.17 (80.4)
J
18.3 (466)
A (CONDENSATE OUTLET)
0.94 (23.9)
B
3.93 (100)
C
1.91 (48.6)
8.73 (221.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
RUS65e (KCM2025W) Type of Appliance
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified
Rinnai model number
REU-KCM2025W-US
Operation / Installation
Forced combustion; outdoor only; Certified for installation in Manufactured (Mobile) Homes
Minimum/Maximum Gas Rate (Input)
10,300 - 130,000 BTU/h
Electrical
Appliance: Temperature Controller:
Electrical Consumption
Normal: 61 w
Standby: 1.3 w
Amperage
Max: 2.3A
Fuse: 10A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)
Temperature (with remote)
120° - 140° F (49°- 60°C)
Temperature (without remote)
120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)
Approved Gas Types
Natural or Propane (ensure unit matches gas type)
Uniform Energy Factor (UEF)
0.90
Service Connections
Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control and fixed by-pass
Minimum/Maximum Water Supply Pressure
50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)
High Altitude Capability
Up to 5,400 ft (1646 m) elevation above sea level
AC 120 Volts - 60 Hz DC 12 Volts Anti-frost protection: 140 w
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
10.0 (37.9)
Water Flow gpm (l/min)
9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0
25 (13.9)
50 (27.8)
75 (41.6)
100 (55.6)
delta T - Temperature Rise ºF (ºC) © 2017 Rinnai Corporation
RUS65e-SP-2
5/2017 C
US
Low Lead Content NSF/ANSI 372
SANITATION
125 (69.4)
150 (83.3)
RUS65e (KCM2025FFW) Controller (Optional)
MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 12 inches (305mm) Front (Panel) - 24 inches (610mm) Front (Exhaust) - 24 inches (610mm)
Back of heater - 0 inches Bottom of heater - 12 inches (305mm) Sides of heater - 6 inches (152mm)
Clearances from Non-combustibles
Top of heater - 2 inches (51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches (610mm)
Back of heater - 0 inches Bottom of heater - 2 inches (51mm) Sides of heater - 1/8 inch (3.2mm)
* 24 inches (610mm) required for service
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.02” W.C. (5.0mbar) low fire 0.89” W.C. (2.2mbar) Propane Gas: high fire 2.32” W.C. (5.8mbar) low fire 0.96” W.C. (2.4mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS
WEIGHT: 57.3 lb (26 kg) 18.5 (470)
0.4 (10.1)
10.1 (257)
9.4 (238)
D
4.6 (117.3)
18.5 (470) 9.4
4.6
B
25.7 (653.2)
0.44
A
28.4 (721.4)
0.44 (11.1)
C
H E
F
I
G J
DIM
Inches (mm)
DIM
A (GAS)
1.3 (33.2)
D
0.09 (2.2)
A (COLD)
1.93 (49)
E
5.6 (142.3)
A (HOT)
1.35 (34.4)
F
3.24 (82.4)
A (CONDENSATE OUTLET)
G
3.99 (101.4)
0.94 (23.9)
H
1.58 (40.1)
B
3.93 (100)
I
3.17 (80.4)
C
1.91 (48.6)
J
18.3 (466)
Inches (mm)
8.73 (221.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
RUCS75i (KCM2528FFU) Type of Appliance
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified
Rinnai model number
REU-KCM2528FFU-US
Operation / Installation
Forced combustion; indoor only; Certified for installation in Manufactured (Mobile) Homes
Minimum/Maximum Gas Rate (Input)
10,300 - 160,000 BTU/h
Electrical
Appliance: Temperature Controller:
Electrical Consumption
Normal: 89 w
Standby: 1.3 w Anti-frost protection: 167 w
Amperage
Max: 2.3A
Fuse: 10A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)
Temperature (with remote)
120° - 140° F (49°- 60°C)
Temperature (without remote)
120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)
Approved Gas Types
Natural or Propane (ensure unit matches gas type)
Uniform Energy Factor (UEF)
0.90
Service Connections
Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control and fixed by-pass
Minimum/Maximum Water Supply Pressure
50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)
High Altitude Capability
Up to 5,400 ft (1646 m) elevation above sea level
AC 120 Volts - 60 Hz DC 12 Volts
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
10.0 (37.9)
Water Flow gpm (l/min)
9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0
25 (13.9) © 2017 Rinnai Corporation
RUCS75i-SP-2
50 (27.8) 75 (41.6) 100 (55.6) delta T - Temperature Rise ºF (ºC) 5/2017 C
US
Low Lead Content NSF/ANSI 372
SANITATION
125 (69.4)
150 (83.3)
RUCS75i (KCM2528FFU) Controller (Optional)
MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 6 inches (152mm) Back of heater - 0 inches Front of heater - 6 inches *(152mm) Bottom of heater - 12 inches (305mm) Sides of heater - 2 inches (51mm) From vent pipe - 0 inches
* 24 inches (610mm) required for service Clearances from Non-combustibles * 24 inches (610mm) required for service
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Top of heater - 2 inches (51mm) Back of heater - 0 inches Front of heater - 6 inches *(152mm) Bottom of heater - 12 inches (305mm) Sides of heater - 1/2 inches (13mm) From vent pipe - 0 inches
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 3.37” W.C. (8.4mbar) low fire 1.00” W.C. (2.5mbar) Propane Gas: high fire 3.75” W.C. (9.3mbar) low fire 1.08” W.C. (2.7mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Venting
Direct Vent system designed for use with Ubbink Polypropylene Concentric Vent, Twin Pipe PVC/CPVC (3” and 4” configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adapter) See installation and operation manual for details regarding installation and allowed vent lengths.
Limited Warranty
Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
WEIGHT: 57.3 lb (26 kg) 10.1 (257)
ø 5.5 (140.2) 5.9 (150)
2 (50.6)
1.2 (30.7)
DIMENSIONS
D
B C
H
A
28.5 (723)
25.7 (653.2)
31.1 (789.6)
E
F
I
G J
DIM
Inches (mm)
DIM
Inches (mm)
A (GAS)
1.3 (33.2)
D
0.09 (2.2)
A (COLD)
1.93 (49)
E
5.6 (142.3)
A (HOT)
1.35 (34.4)
F
3.24 (82.4)
G
3.99 (101.4)
H
1.58 (40.1)
I
3.17 (80.4)
J
18.3 (466)
A (CONDENSATE OUTLET)
0.94 (23.9)
B
3.93 (100)
C
1.91 (48.6)
8.73 (221.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
RUS75e (KCM2528W) Type of Appliance
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified
Rinnai model number
REU-KCM2528W-US
Operation / Installation
Forced combustion; outdoor only; Certified for installation in Manufactured (Mobile) Homes
Minimum/Maximum Gas Rate (Input)
10,300 - 160,000 BTU/h
Electrical
Appliance: Temperature Controller:
Electrical Consumption
Normal: 61 w
Standby: 1.3 w Anti-frost protection: 140 w
Amperage
Max: 2.3A
Fuse: 10A
Ignition System
Direct electronic ignition
Hot Water Capacity
Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)
Temperature (with remote)
120° - 140° F (49°- 60°C)
Temperature (without remote)
120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)
Approved Gas Types
Natural or Propane (ensure unit matches gas type)
Uniform Energy Factor (UEF)
0.90
Service Connections
Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT
Water Flow Control
Water flow sensor, electronic water control and fixed by-pass
Minimum/Maximum Water Supply Pressure
50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)
High Altitude Capability
Up to 5,400 ft (1646 m) elevation above sea level
AC 120 Volts - 60 Hz DC 12 Volts
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
10.0 (37.9)
Water Flow gpm (l/min)
9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0
25 (13.9) © 2017 Rinnai Corporation
RUS75e-SP-2
50 (27.8) 75 (41.6) 100 (55.6) delta T - Temperature Rise ºF (ºC) 5/2017 C
US
Low Lead Content NSF/ANSI 372
SANITATION
125 (69.4)
150 (83.3)
RUS75e (KCM2528W) Controller (Optional)
MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US
Controller Cable
Non-polarized two-core cable, minimum 22 AWG
Safety Devices
Clearances from Combustibles
Top of heater - 12 inches (305mm) Back of heater - 0 inches Front (Panel) - 24 inches (610mm) Bottom of heater - 12 inches (305mm) Front (Exhaust) - 24 inches (610mm) Sides of heater - 6 inches (152mm)
Clearances from Non-combustibles
Top of heater - 2 inches (51mm) Back of heater - 0 inches Front (Panel) - 0 inches * Bottom of heater - 2 inches (51mm) Front (Exhaust) - 24 inches (610mm) Sides of heater - 1/8 inch (3.2mm)
* 24 inches (610mm) required for service
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Min. / Max. Gas Supply Pressure
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)
Manifold Gas Pressure (inches W.C.)
Natural Gas: high fire 2.97” W.C. (7.4mbar) low fire 0.89” W.C. (2.2mbar) Propane Gas: high fire 3.49” W.C. (8.7mbar) low fire 0.96” W.C. (2.4mbar)
NOx
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Limited Warranty
Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.
DIMENSIONS
WEIGHT: 57.3 lb (26 kg) 18.5 (470) 9.4 (238)
0.4 (10.1)
10.1 (257)
D
4.6 (117.3)
H
28.4 (721.4)
E 25.7 (653.2)
0.44 (11.1)
B C
0.44 (11.1)
4.6 (117.3)
18.5 (470) 9.4 (238)
F
I
G J
DIM
Inches (mm)
DIM
A (GAS)
1.3 (33.2)
D
0.09 (2.2)
A (COLD)
1.93 (49)
E
5.6 (142.3)
A (HOT)
1.35 (34.4)
F
3.24 (82.4)
A (CONDENSATE OUTLET)
G
3.99 (101.4)
0.94 (23.9)
H
1.58 (40.1)
B
3.93 (100)
I
3.17 (80.4)
C
1.91 (48.6)
J
18.3 (466)
Inches (mm)
A 8.73 (221.8)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Vent-Free Fan Convectors The Rinnai Vent-Free Fan Convector is the perfect solution for rooms that are hard to heat. Incorporating a convection fan, this, gas-fired appliance evenly distributes comfortable warm air to eliminate cold spots in the most challenging installations.
Vent-Free Fan Convectors
Product Description
Min/Max Heating Input BTU
Fan Output (CFM Low / High)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs/kg)
Noise Level (dB/A)
List Price (U.S.)
FC510N
Fan Convector Vent Free Heater -10K BTU
5500/10000
67.8 / 97.8
23 x 22 x 13
26.5/12.0
28-38
$892
FC510P
Fan Convector Vent Free Heater -10K BTU
5600/10000
67.8 / 97.8
23 x 22 x 13
26.5/12.0
28-38
$892
FC824N
Fan Convector Vent Free Heater -24K BTU
8400/24000
109.5 / 215.4
27 x 22 x 13
33/14.9
30-44
$1,075
FC824P
Fan Convector Vent Free Heater -24K BTU
8000/22000
109.5 / 215.4
27 x 22 x 13
33/14.9
30-44
$1,075
Model Number
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • When ordering, please specify gas type with a “P” for Propane and a “N” for Natural Gas. Rinnai Vent-Free Fan Convectors are a supplemental heat source according to IFGC and should be used in applications as such. Codes vary from state to state. It is necessary to verify the approval of use of vent-free heaters based on local codes for your area. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial, federal and national gas fuel codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada, and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018
FC510 (RCE-391A-H) Type of Appliance
Vent free gas fan convection heater, suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RCE-391A-H-N (Natural gas)
RCE-391A-H-P (Propane)
Gas Rate Input (BTU/hour)
Low - 5,500 High - 10,000
Low - 5,600 High - 10,000
Minimum Gas Supply Pressure
3.5 in (135 mm) W.C.
8.0 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.5 in (267 mm) W.C
13.0 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 19 watts
Gas Connection
1/2 inch Male NPT
Combustion System
Ceramic Burner
Ignition System
Electronic spark ignition
Fan CFM Output
Low: 67.8
Temperature Settings
Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat
Weight
Approximately 22.1 lbs (10 kg)
Clearance from Combustibles
Side: 2 in. (50 mm), Top: 2 in. (50 mm), Front: 30 in. (762 mm) Back: 2 in. (50 mm), Bottom: 0 in.
Noise Level
Low-28dB
Warm Air Outlet
Bottom front louvers
Maximum Installation Elevation
5,200 Feet
FEATURES
High: 97.8
High-38dB
99.9% Efficient Cool-to-the-touch cabinet Modulating Technology Programmable Thermostat Child-Safety Lock Digital, Adaptive Control Electronic Iginition - No Pilot Light On Board Self-Diagnostics for Easier Maintenance Tilt Switch Push-Button, Electronic Ignition
© 2015 Rinnai Corporation
FC510 (RCE-391A-H SP)
7/2015
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
FC510 (RCE-391A-H)
Safety Devices
Overheat Switch: The appliance will automatically shut down when the appliance exceeds a predetermined temperature. Flame Failure Device: The appliance will automatically shut down if the burner flame is extinguished.
Oxygen Depletion Sensor: If the oxygen level in the room drops below a preset limit, this sensor disables the gas supply to the heater.
Tilt Switch: If the heater is knocked over, the tilt switch will disable the gas supply. The fan will continue to purge. Convection fan continues to run after burner shutdown to cool internal parts.
Child Lock: Prevents inadvertent operation.
Power Failure: The appliance will disable the gas supply if it loses electrical power.
Fuse: The electrical circuits are protected by a fuse. When the 5 amp fuse blows, the heater will not operate until the 5 amp fuse is replaced.
Warranty
3 years from date of purchase on all parts
Conversion Kit
NA-Unit is not field convertible
ATTENTION This appliance is intended for supplemental heating only. The International Fuel Gas Code Standard 620-6 “Prohibited Use” states that “One or more unvented room heaters shall not be used as a sole source of comfort heating in any dwelling”.
19.2 in (487 mm)
19.4 in (492 mm)
DIMENSIONS
9.6 in (244 mm)
Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269 Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us ©2015 Rinnai America Corporation. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation.
FC824 (RCE-691TA-H) Type of Appliance
Vent free gas fan convection heater, suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RCE-691TA-H-N (Natural gas)
RCE-691TA-H-P (Propane)
Gas Rate Input (BTU/hour)
Low - 8,400 High - 24,000
Low - 8,000 High - 22,000
Minimum Gas Supply Pressure
5.0 in (135 mm) W.C.
8.0 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.0 in (266 mm) W.C
13.0 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 29 watts
Gas Connection
1/2 inch Male NPT
Combustion System
Ceramic Burner
Ignition System
Electronic spark ignition
Fan CFM Output
Low: 109.5
Temperature Settings
Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat
Weight
Approximately 26.5 lbs (12 kg)
Clearance from Combustibles
Side: 2 in. (50 mm), Top: 2 in. (50 mm), Front: 30 in. (762 mm) Back: 2 in. (50 mm), Bottom: 0 in.
Noise Level
Low-30dB
Warm Air Outlet
Bottom front louvers
Maximum Installation Elevation
5,200 Feet
FEATURES
High: 215.4
High-44dB
99.9% Efficient Cool-to-the-touch cabinet Modulating Technology Programmable Thermostat Child-Safety Lock Digital, Adaptive Control Electronic Ignition - No Pilot Light On Board Self-Diagnostics for Easier Maintenance Tilt Switch Push-Button, Electronic Ignition
© 2015 Rinnai Corporation
FC824 (RCE-691TA-H SP)
7/2015
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
FC824 (RCE-691TA-H)
Safety Devices
Overheat Switch: The appliance will automatically shut down when the appliance exceeds a predetermined temperature. Flame Failure Device: The appliance will automatically shut down if the burner flame is extinguished.
Oxygen Depletion Sensor: If the oxygen level in the room drops below a preset limit, this sensor disables the gas supply to the heater.
Tilt Switch: If the heater is knocked over, the tilt switch will disable the gas supply. The fan will continue to purge. Convection fan continues to run after burner shutdown to cool internal parts.
Child Lock: Prevents inadvertent operation.
Power Failure: The appliance will disable the gas supply if it loses electrical power.
Fuse: The electrical circuits are protected by a fuse. When the 5 amp fuse blows, the heater will not operate until the 5 amp fuse is replaced.
Warranty
3 years from date of purchase on all parts
Conversion Kit
NA-Unit is not field convertible
ATTENTION This appliance is intended for supplemental heating only. The International Fuel Gas Code Standard 620-6 “Prohibited Use” states that “One or more unvented room heaters shall not be used as a sole source of comfort heating in any dwelling”.
24 in (610 mm)
19 in (482 mm)
DIMENSIONS
9.4 in (239 mm)
Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269 Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us ©2015 Rinnai America Corporation. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation.
EnergySaver® Direct Vent Wall Furnaces Designed to constantly monitor room temperatures, the Rinnai Direct Vent Wall Furnaces feature unique modulating technology that responds immediately to even the smallest temperature fluctuations.
Direct Vent Wall Furnaces Model Number
Min/Max Heating Input BTU
AFUE
Shipping Dimensions - Inches (W x H x D)
Shipping Weight lbs (kg)
Noise Level (dB/A)
List Price (U.S.)
EX08CTN
3000/8000
0.82
17 x 31 x 21
48 (21.8)
27-36
$1,385
EX08CTP
3000/8000
0.82
17 x 31 x 21
48 (21.8)
27-36
$1,385
EX11CTN
5500/11000
0.81
17 x 31 x 21
48 (21.8)
31-38
$1,657
EX11CTP
5700/11000
0.81
17 x 31 x 21
48 (21.8)
31-38
$1,657
EX17CTN
8200/16700
0.81
12 x 33 x 32.5
73 (33.1)
33-38
$1,983
EX17CTP
8200/16700
0.81
12 x 33 x 32.5
73 (33.1)
33-38
$1,983
EX22CTN
8200/21500
0.81
12 x 33 x 32.5
73 (33.1)
33-42
$2,192
EX22CTP
8200/20700
0.81
12 x 33 x 32.5
73 (33.1)
33-42
$2,192
EX22CTWN
8200/21500
0.81
12 x 33 x 32.5
73 (33.1)
33-42
$2,192
EX22CTWP
8200/20700
0.81
12 x 33 x 32.5
73 (33.1)
33-42
$2,192
EX38CTN
13200/38400
0.80
16.54 x 30.12 x 39.37
88 (39.9)
39-46
$2,612
EX38CTP
13200/36500
0.80
16.54 x 30.12 x 39.37
88 (39.9)
39-46
$2,612
EX38CTWN
13200/38400
0.80
16.54 x 30.12 x 39.37
88 (39.9)
39-46
$2,612
EX38CTWP
13200/36500
0.80
16.54 x 30.12 x 39.37
88 (39.9)
39-46
$2,612
Conversion Kits Item Number
TO NG
TO LP
List Price (U.S.)
EX08C
204000033
204000037
$11
EX11C
204000034
204000038
$11
EX17C
204000035
204000039
$11
EX22C / EX22CW
204000036
204000040
$11
EX38C / EX38CW
203000001
203000002
$95
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • When ordering, please specify gas type with a “P” for Propane and a “N” for Natural Gas. • All “T” Models require Rinnai Wall Thermostat Installation Kit 204000045 or 204000048 with customer supplied thermostat (2 or 3 wire type). Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 02/01/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Venting for Direct Vent Wall Furnaces Vent Terminations Item Number
Product Description
List Price (U.S.)
FOT-150
S Vent (3” - 4 1/2”)
$115
FOT-151
A Vent (4 1/2” - 9 1/2”) Included with each unit
$117
FOT-152
B Vent (9 1/2” - 15 3/4”)
$156
FOT-153
C Vent (15 3/4” - 23 5/8”)
$156
FOT-154
D Vent (23 5/8” - 31 1/2”)
$233
Extensions Item Number
Fits Model Number
Product Description
List Price (U.S.)
FOT-155
EX11C
12” - 20” Vent Pipe Extension
$102
FOT-156
EX11C
21” - 40” Vent Pipe Extension
$149
FOT-157
EX11C
60” - 80” Vent Pipe Extension
$183
FOT-158
EX11C / EX17C / EX22C
Elbow
$56
FOT-201
EX11C/ EX17C / EX22C
Long Elbow w/Intake Hose
$83
FOT-219
EX17C / EX22C
11” – 20” Vent Pipe Extension
$130
FOT-220
EX17C / EX22C
21” – 40” Vent Pipe Extension
$195
FOT-221
EX17C / EX22C
60” – 80” Vent Pipe Extension
$250
FOT-102
EX38C
11” - 20” Vent Pipe Extension
$125
FOT-103
EX38C
21” - 40” Vent Pipe Extension
$160
FOT-114
EX38C
60” - 80” Vent Pipe Extension
$207
FOT-115
EX38C
Elbow
$59
Extension Pipe Cover Kits & Wall Thermostat Installation Kits Item Number
Product Description
List Price (U.S.)
FOT-132*
Manifold Cover A for ES38, ES38W
$175
FOT-133*
Straight Cover A for ES38, ES38W
$238
FOT-134*
Elbow Cover A for ES38, ES38W
$107
FOT-140*
Manifold Cover B for EX11C, EX17C, EX22C (W)
$165
FOT-141*
Pipe Cover B for EX11C, EX17C, EX22C (W)
$143
FOT-142*
Elbow Cover B for EX11C, EX17C, EX22C (W)
$102
FOT-269
Relay Board Wall Thermostat
$115
204000045
Wall Thermostat Installation Kit (U.S. Market Only)
$80
204000048
Wall Thermostat Installation Kit (Canadian. Market Only)
$116
*Special order, confirm leadtimes.
2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 02/01/2018
EX08CT (RHFE-202FTA2) Type of Appliance
Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RHFE-202FTA2-N (Natural gas)
RHFE-202FTA2-P (Propane)
Gas Rate Input (BTU/hour)
Low - 3,000 High - 8,000
Low - 3,000 High - 8,000
Gas Rate Output (BTU/hour)
Low - 2,400 High - 6,400
Low - 2,400 High - 6,400
AFUE Rating
82%
Minimum Gas Supply Pressure
4.5 in (114 mm) W.C.
8 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 41 watts
Gas Connection
1/2 inch NPT
Combustion System
Stainless steel Bunsen burners
Ignition System
Electronic spark ignition
Fan CFM Output
Low - 48.3
Temperature Settings
Low (LO): minimum combustion 60°- 80° F in 2° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat Temperature limiting program to comply with Inside Design Temperature limits
Humidifier Tray
Enameled tray with capacity of 1.5 pints (700 cc)
Weight
Approximately 46 lbs (21 kg)
Clearance from Combustibles
Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)
Noise Level
27 - 36 dB(A)
Warm Air Outlet
Bottom front louvers
High - 78.6
FEATURES Restart capability
Restarts automatically when ignition or combustion fails.
Timer Settings
Starts and turns off the heater at 2 timer settings.
Seven-stage modulating gas valve
Provides precise gas flow by operating from one to seven stages.
Negative coefficient thermistor
Detects temperature change in 1/2 of a degree.
Variable speed inducer motor with pressure switch
Monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph.
Self diagnostic electronics
Continually monitors functions; provides auto shutdown codes; indicates
Quiet operation
Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.
Wall Thermostat connectable
Ability to connect to a field supplied wall thermostat.
© 2017 Rinnai Corporation
RHFE-202FTA2 SP
8/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX08CT (RHFE-202FTA2) Safety Devices
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown 3 amp fuse protects against power surge; results in auto shutdown Abnormal spark at time of ignition results in auto shutdown Combustion fan purges any gas from the combustion chamber before ignition Convection fan continues to run after burner shutdown to cool internal parts Child lock prevents inadvertent operation Appliance shuts down if room reaches 104° F (40° C)
Venting
Concentric; 3 1/8 inch (80 mm) wall hole
Maximum Vent Length
No extensions allowed; flue manifold termination connects directly to unit
Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)
Name
Kit No.
Fits Walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Warranty
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Conversion Kit
To natural gas: 204000033
To propane gas: 204000037
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX08CT (RHFE-202FTA2)
Clearance for Maintenance
Clearance to Combustibles
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX08CT (RHFE-202FTA2)
Zone Cubic Feet Square Feet* 1
-5,470
-680
2
- 3,550
- 440
3
- 2,980
- 370
4
- 2,520
- 320
5
- 2,080
- 260
6
- 1,700
- 210
7
- 1,550
- 190
Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai.
In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider.
Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer.
Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project.
Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection.
Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed.
Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes.
Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX11CT (RHFE-265FTA2) Type of Appliance
Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RHFE-265FTA2-N (Natural gas)
RHFE-265FTA2-P (Propane)
Gas Rate Input (BTU/hour)
Low - 5,500 High - 11,000
Low - 5,700 High - 11,000
Gas Rate Output (BTU/hour)
Low - 4,400 High - 8,800
Low - 4,560 High - 8,800
AFUE Rating
81%
Minimum Gas Supply Pressure
3.5 in (89 mm) W.C.
8 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 44 watts
Gas Connection
1/2 inch NPT
Combustion System
Stainless steel Bunsen burners
Ignition System
Electronic spark ignition
Fan CFM Output
Low - 96.4
Temperature Settings
Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat Temperature limiting program to comply with Inside Design Temperature limits
Humidifier Tray
Enameled tray with capacity of 1.5 pints (700 cc)
Weight
Approximately 46 lbs (21 kg)
Clearance from Combustibles
Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)
Noise Level
31 - 38 dB(A)
Warm Air Outlet
Bottom front louvers
High - 128.5
FEATURES Restart capability
Restarts automatically when ignition or combustion fails.
Timer Settings
Starts and turns off the heater at 2 timer settings.
Seven-stage modulating gas valve
Provides precise gas flow by operating from one to seven stages.
Negative coefficient thermistor
Detects temperature change in 1/2 of a degree.
Variable speed inducer motor with pressure switch
Monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph.
Self diagnostic electronics
Continually monitors functions; provides auto shutdown codes; indicates
Quiet operation
Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.
Wall Thermostat connectable
Ability to connect to a field supplied wall thermostat.
© 2017 Rinnai Corporation
RHFE-265FTA2 SP
8/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX11CT (RHFE-265FTA2) Safety Devices
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown 3 amp fuse protects against power surge; results in auto shutdown Abnormal spark at time of ignition results in auto shutdown Combustion fan purges any gas from the combustion chamber before ignition Convection fan continues to run after burner shutdown to cool internal parts Child lock prevents inadvertent operation Appliance shuts down if room reaches 104° F (40° C)
Venting
Concentric; 3 1/8 inch (80 mm) wall hole
Maximum Vent Length
13 feet (4 m) with a maximum of 2 bends; maximum 8 ft (2.4 m) vertically for altitudes at or below 2000 ft (610 m) maximum 5 ft (1.5 m) vertically for altitudes above 200 ft (610 m)
Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)
Name
Kit No.
Fits Walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Warranty
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Conversion Kit
To natural gas: 204000034
To propane gas: 204000038
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX11CT (RHFE-265FTA2)
Clearance for Maintenance
Clearance to Combustibles
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX11CT (RHFE-265FTA2)
Zone
Cubic Feet
Square Feet*
1
5,471 -7,430
681
-930
2
3,551 - 4,820
441
- 600
3
2,981 - 4,050
371
- 510
4
2,521 - 3,430
321
- 430
5
2,081 - 2,830
261
- 350
6
1,701 - 2,310
211
- 290
7
1,551 - 2,110
191
- 260
Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX17CT (RHFE-434FTA2) Type of Appliance
Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RHFE-434FTA2-N (Natural gas)
RHFE-434FTA2-P (Propane)
Gas Rate Input (BTU/hour)
Low - 8,200 High - 16,700
Low - 8,200 High - 16,700
Gas Rate Output (BTU/hour)
Low - 6,560 High - 13,360
Low - 6,560 High - 13,360
AFUE Rating
81%
Minimum Gas Supply Pressure
3.5 in (89 mm) W.C.
8 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 46 watts
Gas Connection
1/2 inch NPT
Combustion System
Stainless steel Bunsen burners
Ignition System
Electronic spark ignition
Fan CFM Output
Low: 110.5
Temperature Settings
Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat Temperature limiting program to comply with Inside Design Temperature limits
Humidifier Tray
Enameled tray with capacity of 2.1 pints (1000 cc)
Weight
Approximately 57 lbs (26 kg)
Clearance from Combustibles
Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)
Noise Level
33 - 38 dB(A)
Warm Air Outlet
Bottom front louvers
High: 141.3
FEATURES Restart capability
Restarts automatically when ignition or combustion fails.
Timer Settings
Starts and turns off the heater at 2 timer settings.
Seven-stage modulating gas valve
Provides precise gas flow by operating from one to seven stages.
Negative coefficient thermistor
Detects temperature change in 1/2 of a degree.
Variable speed inducer motor with
Monitors and controls combustion fan and allows the appliance to overcome
Self diagnostic electronics
Continually monitors functions; provides auto shutdown codes; indicates
Quiet operation
Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.
Wall Thermostat connectable
Ability to connect to a field supplied wall thermostat.
© 2017 Rinnai Corporation
RHFE-434FTA2 SP
8/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX17CT (RHFE-434FTA2) Safety Devices
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown 3 amp fuse protects against power surge; results in auto shutdown Abnormal spark at time of ignition results in auto shutdown Combustion fan purges any gas from the combustion chamber before ignition Convection fan continues to run after burner shutdown to cool internal parts Child lock prevents inadvertent operation Appliance shuts down if room reaches 104° F (40° C)
Venting
Concentric; 3 1/8 inch (80 mm) wall hole
Maximum Vent Length
13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically
Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)
Name
Kit No.
Fits Walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Warranty
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Conversion Kit
To natural gas: 204000035
To propane gas: 204000039
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX17CT (RHFE-434FTA2)
Clearance for Maintenance
Clearance to Combustibles
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX17CT (RHFE-434FTA2)
Zone
Cubic Feet
Square Feet*
1
7,431 -11,270 931
-1,410
2
4,821 - 7,310
601
- 910
3
4,051 - 6,150
511
- 770
4
3,431 - 5,200
431
- 650
5
2,831 - 4,290
351
- 540
6
2,311 - 3,510
291
- 440
7
2,111 - 3,210
261
- 400
Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX22CT (RHFE-559FTA2) Type of Appliance
Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RHFE-559FTA2-N (Natural gas)
RHFE-559FTA2-P (Propane)
Gas Rate Input (BTU/hour)
Low - 8,200 High - 21,500
Low - 8,200 High - 20,700
Gas Rate Output (BTU/hour)
Low - 6,560 High - 17,200
Low - 6,560 High - 16,560
AFUE Rating
81%
Minimum Gas Supply Pressure
3.5 in (89 mm) W.C.
8 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 56 watts
Gas Connection
1/2 inch NPT
Combustion System
Stainless steel Bunsen burners
Ignition System
Electronic spark ignition
Fan CFM Output
Low: 110.5
Temperature Settings
Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat Temperature limiting program to comply with Inside Design Temperature limits
Humidifier Tray
Enameled tray with capacity of 2.1 pints (1000 cc)
Weight
Approximately 57 lbs (26 kg)
Clearance from Combustibles
Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)
Noise Level
33 - 42 dB(A)
Warm Air Outlet
Bottom front louvers
High: 162.7
FEATURES Restart capability
Restarts automatically when ignition or combustion fails.
Timer Settings
Starts and turns off the heater at 2 timer settings.
Seven-stage modulating gas valve
Provides precise gas flow by operating from one to seven stages.
Negative coefficient thermistor
Detects temperature change in 1/2 of a degree.
Variable speed inducer motor with pressure switch
Monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph.
Self diagnostic electronics
Continually monitors functions; provides auto shutdown codes; indicates
Quiet operation
Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.
Wall Thermostat connectable
Ability to connect to a field supplied wall thermostat.
© 2017 Rinnai Corporation
RHFE-559FTA2 SP
8/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX22CT (RHFE-559FTA2) Safety Devices
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown 3 amp fuse protects against power surge; results in auto shutdown Abnormal spark at time of ignition results in auto shutdown Combustion fan purges any gas from the combustion chamber before ignition Convection fan continues to run after burner shutdown to cool internal parts Child lock prevents inadvertent operation Appliance shuts down if room reaches 104° F (40° C)
Venting
Concentric; 3 1/8 inch (80 mm) wall hole
Maximum Vent Length
13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically
Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)
Name
Kit No.
Fits Walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Warranty
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Conversion Kit
To natural gas: 204000036
To propane gas: 204000040
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX22CT (RHFE-559FTA2)
Clearance for Maintenance
Clearance to Combustibles
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX22CT (RHFE-559FTA2)
Zone
Cubic Feet
Square Feet*
1
11,271 -14,510 1,411 -1,810
2
7,311
- 9,410
911 - 1,180
3
6,151
- 7,920
771
- 990
4
5,201
- 6,700
651
- 840
5
4,291
- 5,530
541
- 690
6
3,511
- 4,520
441
- 570
7
3,211
- 4,130
401
- 520
Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX38CT (RHFE-1005FTA2) Type of Appliance
Direct vent wall furnace suitable for homes, apartments, and condominiums; modular/mobile home approved; forced combustion, forced convection
Rinnai Model Number
RHFE-1005FTA2-N (Natural gas) RHFE-1005FTA2-P (Propane)
Gas Rate Input (BTU/hour)
Low - 13,200 High - 38,400
Low - 13,200 High - 36,500
Gas Rate Output (BTU/hour)
Low - 10,560 High - 30,720
Low - 10,560 High - 29,200
AFUE Rating
80%
Minimum Gas Supply Pressure
3.5 in (89 mm) W.C.
8 in (203 mm) W.C.
Maximum Gas Supply Pressure
10.5 in (267 mm) W.C
13 in (330 mm) W.C.
Electrical Connection
AC 120V, 60 Hz, 117 watts
Gas Connection
1/2 inch FNPT
Combustion System
Stainless Steel Bunsen Burners
Ignition System
Electronic spark ignition
Temperature Settings
Low (LO): minimum combustion 60° - 80° F in 1° increments High (HI): maximum combustion
Temperature Control
Electronic thermostat Temperature limiting program to comply with Inside Design Temperature limits
Humidifier Tray
Enameled tray with capacity of 6.3 pints (3 liters)
Weight
Approximately 88 lbs (40 kg)
Clearance from Combustibles
Side: 2 inches (50 mm) Front: 40 inches (1 m)
Noise Level
39 - 46 dB(A)
Warm Air Outlet
Bottom front louvers
Top: 10 inches (250 mm)
FEATURES Timer Settings
Starts and turns off the heater at two timer settings
Seven-stage modulating gas valve
provides precise gas flow by operating from one to seven stages
Negative coefficient thermistor
detects temperature change in 1/2 of a degree
Variable speed inducer motor with pressure switch
monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph
Quiet operation
reduces noise through use of swept blades in convection fan; and through the design of the combustion chamber and heat exchanger which silently
Self diagnostic electronic
continually monitors functions; provides auto shutdown codes; indicates
Wall Thermostat connectable
Ability to connect to a field supplied wall thermostat
© 2017 Rinnai Corporation
RHFE-1005FTA2-SP
8/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX38CT (RHFE-1005FTA2) Safety Devices
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas Thermal fuse, and thermistor detect overheat condition; results in auto shutdown 5 amp fuse protects against power surge; results in auto shutdown Abnormal spark at time of ignition results in auto shutdown Combustion fan purges any gas from the combustion chamber before ignition Convection fan continues to run after burner shutdown to cool internal parts Function lock prevents inadvertent operation Appliance shuts down if room reaches 104° F (40° C)
Venting
Concentric; 3 1/8 inch (80 mm) wall hole
Maximum Vent Length
13 feet (4 m) with a maximum of 2 bends
Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)
Name
Kit No.
Fits Walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Wall Thermostat Kit
204000045 (US); 204000048 Canada
Warranty
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
EX38CT (RHFE-1005FTA2)
Clearance to Combustibles
Clearance for Maintenance
© 2016 Rinnai Corporation
RHFE-1005FTA2-SP
12/2016
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
EX38CT (RHFE-1005FTA2)
Zone
Cubic Feet
Square Feet*
1
14,5111 -25,600 1,811 -3,200
2
9,411 - 16,610 1181 - 2,080
3
7,921 - 13,960 991
- 1,750
4
6,701 - 11,820 841
- 1,480
5
5,531
- 9,750
691
- 1,220
6
4,521
- 7,980
571
- 1,000
7
4,131
- 7,280
521
- 910
Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Condensing Gas Boilers For maximum momentum. Using proven technology, these boilers offer three distinct advantages above and beyond the average boiler. The M-Series condensing gas boiler from Rinnai is designed to provide fast, easier installation, operational performance with efficient heating, and simplified serviceability.
Rinnai M-Series Wall-Mounted Product Description
Min / Max Input-Heating (Btu/h & kW)
Min / Max Input - DHW (Btuh/kW)
Max Flow Rate Domestic Hot Water (70° F Delta T)
AFUE
Shipping Dimensions - Inches (W x H x D)
Shipping Weight (lbs/kg)
List Price (U.S.)
M060CN
Boiler Max HTG Btu 60K DHW 103K Combi, NG
17,000 / 60,000 (5.0 / 17.6)
17,000 / 103,000 (5.0 / 30.2)
2.6 / 9.8
95.0%
31.5 x 12 x 23
88/40
$3,380
M090CN
Boiler Max HTG Btu 90K DHW 160K Combi, NG
23,500 / 90,000 (6.9 / 26.4)
23,500 / 160,000 (6.9 / 46.9)
4.2 / 15.9
95.0%
31.5 x 12 x 23
95/43
$3,790
M120CN
Boiler Max HTG Btu 120K DHW 160K Combi, NG
23,500 / 120,000 (6.9 / 35.1)
23,500 / 160,000 (6.9 / 46.9)
4.2 / 15.9
95.0%
31.5 x 12 x 23
95/43
$3,895
M160CN
Boiler Max HTG DHW Btu 23,500 / 160,000 160,000 Combi, NG (6.9 / 46.9)
23,500 / 160,000 (6.9 /46.9)
4.2 / 15.9
95.0%
31.5 x 12 x 23
95/43
$4,175
Model Number Combi Boilers
Heat Only Boilers M060SN
Boiler Max HTG Btu 60,000 Solo, NG
17,000/ 60,000 (5.0 / 17.6)
N/A
N/A
95.0%
31.5 x 12 x 23
75/34
$2,965
M090SN
Boiler Max HTG Btu 90,000 Solo, NG
17,000 / 90,000 (5.0 / 26.4)
N/A
N/A
95.0%
31.5 x 12 x 23
75/34
$3,360
M120SN
Boiler Max HTG Btu 120,000 Solo, NG
23,500 / 120,000 (6.9 / 35.1)
N/A
N/A
95.0%
31.5 x 12 x 23
81/37
$3,375
M160SN
Boiler Max HTG Btu 160,000 Solo, NG
23,500 / 160,000 (6.9 / 46.9)
N/A
N/A
95.0%
31.5 x 12 x 23
81/37
$3,710
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • “C” in the model number is for “Combi”, “S” is “Solo”, • LP Conversion Kit included with all Natural Gas, “N” models. • Plumbing kit available for all models. • Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial, federal and national gas fuel codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (U.S.) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Condensing Gas Boilers Rinnai offers condensing gas boilers that can be easily retro-fitted to replace traditional less efficient boilers or provide simple, space-saving installation in new builds. They feature exclusive stainless steel heat exchanger to deliver unparalleled performance efficiency.
Rinnai E-Series Wall-Mounted Condensing Gas Boilers Product Description
Min / Max Input-Heating (Btuh/kW)
Min / Max Input - DHW (Btuh/kW)
Max Flow Rate Domestic Hot Water (70° F Delta T) GPM / LPM
AFUE
Shipping Dimensions Inch;es (W x H x D)
Shipping Weight (lbs/kg)
List Price (U.S.)
E50CRN
Combi Condensing Boiler
13,600 / 50,000 (4 / 14.6)
13,600 / 85,000 (4 / 24.9)
2.3/8.5
95.6%
20 x 26 x 16
93/42
$2,580
E75CRN
Combi Condensing Boiler
13,600 / 75,000 (4 / 22)
13,600 / 85,000 (4 / 24.9)
2.3/8.5
95.5%
20 x 26 x 16
96/44
E75CRP
Combi Condensing Boiler
37,000 / 75,000 (10.8 / 22)
37,000/85,000 (10.8 / 24.9)
2.3/8.5
95.5%
20 x 26 x 16
96/44
E110CRN
Combi Condensing Boiler
26,000 / 110,000 (7.6 / 32.2)
26,000 / 130,000 (7.6 / 38.1)
3.4/13.0
95.5%
20 x 34 x 16
110/50
E110CRP
Combi Condensing Boiler
59,000 / 110,000 (17.3 / 32.2)
59,000/130,000 (17.3 / 38.1)
3.4/13.0
95.5%
20 x 34 x 16
110/50
Model Number Combi Boilers
$2,790
$3,015
Heat Only Boilers E60SRN
Condensing Boiler Heat Only
13,600 / 60,000 (4 / 17.6)
N/A
N/A
95.6%
20 x 26 x 16
90/41
E60SRP
Condensing Boiler Heat Only
37,000 / 60,000 (10.8 / 17.6)
N/A
N/A
95.6%
20 x 26 x 16
90/41
E85SRN
Condensing Boiler Heat Only
13,600 / 85,000 (4 / 24.9)
N/A
N/A
95.4%
20 x 26 x 16
90/41
E85SRP
Condensing Boiler Heat Only
37,000 / 85,000 (10.8 / 24.9)
N/A
N/A
95.4%
20 x 26 x 16
90/41
E110SRN
Condensing Boiler Heat Only
26,000/110,000 (7.6 / 32.2)
N/A
N/A
95.5%
20 x 34 x 16
103/47
E110SRP
Condensing Boiler Heat Only
59,000 / 110,000 (17.3 / 32.2)
N/A
N/A
95.5%
20 x 34 x 16
103/47
$2,190
$2,395
$2,600
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • “C” in the model number is for “Combi”, “S” is “Solo”, “R” is for packaged with modulating pump, parameter changes and without Low Loss Header & Expansion Tank • E50CR model does not include the Concentric Flue Adaptor or Flow Switch. For LP applications, field conversion (NG to LP) is required. • For a list of approved installation venting options, refer to the Owner & Installation Manual.
2018 SUGGESTED LIST PRICE (U.S.) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Rinnai Q-Series Wall-Mounted Condensing Gas Boilers Product Description
Min / Max Input-Heating (Btuh/kW)
Min / Max Input - DHW GPM / LCM
Max Flow Rate Domestic Hot Water (70° F Delta T) GPM / LCM
AFUE
Shipping Dimensions Inch;es (W x H x D)
Shipping Weight (lbs/kg)
List Price (U.S.)
Q130SN
Condensing Boiler
26,000 / 130,000 (7.6/38.1)
N/A
Indirect tank compatible
95.4%
20 x 27 x 15
117/53
$4,250
Q130SP
Condensing Boiler
59,000 / 130,000 (17.3/38.1)
N/A
Indirect tank compatible
95.4%
20 x 27 x 15
117/53
$4,250
Q175SN
Condensing Boiler
35,000 / 175,000 (10.2/51.2)
N/A
Indirect tank compatible
95.0%
26 x 27 x 15
141/64
$4,800
Q175SP
Condensing Boiler
74,000 / 175,000 (21.7/51.2)
N/A
Indirect tank compatible
95.0%
26 x 27 x 15
141/64
$4,800
Q175CN
Condensing Boiler
35,000 / 175,000 (10.2/51.2)
6.2/23.5
4.4/16.6
95.0%
40 x 27 x 15
196/89
$5,800
Q175CP
Condensing Boiler
74,000 / 175,000 (21.7/51.2)
6.2/23.5
4.4/16.6
95.0%
40 x 27 x 15
196/89
$5,800
Q205SN
Condensing Boiler
41,000 / 205,000 (12/60)
N/A
Indirect tank compatible
95.0%
26 x 27 x 15
141/64
$5,200
Q205SP
Condensing Boiler
74,000 / 205,000 (21.7/60)
N/A
Indirect tank compatible
95.0%
26 x 27 x 15
141/64
$5,200
Model Number
Rinnai Q Premier Gas Boilers Model Number
QP130N
Product Description
Min / Max Input-Heating (Btuh/kW)
First Hour Rating (Gallons)
Max Flow Rate Domestic Hot Water (70° F Delta T) GPM / LCM
AFUE
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs/kg)
List Price (U.S.)
Condensing Boiler/ Tank
26,000 / 130,000 (7.6 / 38.1)
211
3.4/13.0
95.4%
24 x 62 x 25
243/110
$6,500
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • “C” in the model number is for “Combi”, “S” is “Solo”, “QP” is for “Q Premier” All-in-one-system • E50CR model does not include the Concentric Flue Adaptor or Flow Switch. For LP applications, field conversion (NG to LP) is required. • For a list of approved installation venting options, refer to the Owner & Installation Manual.
2018 SUGGESTED LIST PRICE (U.S.) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Accessories for Boilers Item Number 803000023
Product Description Plumbing Kit, M-Series Boiler
List Price (U.S.) $333
804000074
Kit, Condensate Neutralizer (All Models)
$85
809000114
Refill, Condensate Neutralizer (All Models)
$30
808000025
Air Intake Filter (All Models)
$132
809000024
Boiler Tool Kit (All Models)
$72
103000038
ScaleCutter System
$210
103000039
ScaleCutter Refill Cartridge
$110
MIVK-T-LW
Plumbing Isolation Valve Kit, Compact design, Ease in Flushing
$109
804000061
E-Series Low Loss Header Kit (LLH, T/P Gauge, Valves, PRV)
$460
804000071
E75C, E110C Side Mount for Low Loss Header Kit
$315
805000040
Flue Gas Sensor with Cable (All Models Excluding M-Series)
$70
808000023
Concentric Flue Adaptor / E50C
803000011
RS100 Room Controller (Excluding Q Premier, and M-Series)
$300
803000015
Flow Switch Conversion Kit / E50C
$176
$32
804000072
Q85S, Q130S Side Mount Low Loss Header Kit
$420
804000073
Q175S, Q175C, Q205S Side Mount Low Loss Header Kit
$525 $240
804000013
3-Way Diverter Valve Kit Q85S & Q130S
804000014
3-Way Diverter Valve Kit Q175S & Q205S
$240
804000079*
Pre-Bend Connect Kit for Q Premier (LEFT)
$500
804000080*
Pre-Bend Connect Kit for Q Premier (RIGHT)
$500
804000081*
Pre-Bend Connect Kit for Q Premier (TOP)
$500
* Pre-Bend Connect Kits are optional accessories for ease of installation.
2018 SUGGESTED LIST PRICE (U.S.) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Gas Conversion Kits Conversion Kits for NG to LP Item Number
Product Description
List Price (U.S.)
803000024
NG to LP Conversion Kit for M060C
$70
803000026
NG to LP Conversion Kit for M060S
$70
803000028
NG to LP Conversion Kit for M090C
$70
803000030
NG to LP Conversion Kit for M090S
$70
803000032
NG to LP Conversion Kit for M120C
$70
803000034
NG to LP Conversion Kit for M120S
$70
803000036
NG to LP Conversion Kit for M160C
$70
803000038
NG to LP Conversion Kit for M160S
$70
803000014
NG to LP Conversion Kit for E50C/E50CR
$48
803000016
NG to LP Conversion Kit for E60SR
$70
803000018
NG to LP Conversion Kit for E85SR
$70
803000020
NG to LP Conversion Kit for E110SR
$70
804000015
NG to LP Conversion Kit for E75C/E75CR
$70
804000016
NG to LP Conversion Kit for E110C/E110CR
$70
804000017
NG to LP Conversion Kit for Q85S
$135
804000018
NG to LP Conversion Kit for Q130S
$135
804000082
NG to LP Conversion Kit for QP85N
$132
804000083
NG to LP Conversion Kit for QP130N
$132
804000089
NG to LP Conversion Kit for Q175S (replaces 804000019)
$392
804000090
NG to LP Conversion Kit for Q175C (replaces 804000021)
$392
804000091
NG to LP Conversion Kit for Q205S (replaces 804000020)
$392
Conversion Kits for LP to NG Item Number
Product Description
List Price (U.S.)
803000025
LP to NG Conversion Kit for M060C
$70
803000027
LP to NG Conversion Kit for M060S
$70
803000029
LP to NG Conversion Kit for M090C
$70
803000031
LP to NG Conversion Kit for M090S
$70
803000033
LP to NG Conversion Kit for M120C
$70
803000035
LP to NG Conversion Kit for M120S
$70
803000037
LP to NG Conversion Kit for M160C
$70
803000039
LP to NG Conversion Kit for M160S
$70
803000017
LP to NG Conversion Kit for E60SR
$70
803000019
LP to NG Conversion Kit for E85SR
$70
803000021
LP to NG Conversion Kit for E110SR
$135
804000023
LP to NG Conversion Kit for E75C/E75CR
$70
804000024
LP to NG Conversion Kit for E110C/E110CR
$135
804000025
LP to NG Conversion Kit for Q85S
$135
804000026
LP to NG Conversion Kit for Q130S
$135
804000027
LP to NG Conversion Kit for Q175S
$135
804000028
LP to NG Conversion Kit for Q205S
$135
804000029
LP to NG Conversion Kit for Q175C
$135
Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial, federal and national gas fuel codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (U.S.) • Page 6 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
CONDENSING WALL-MOUNTED, GAS-FIRED SOLO BOILER (CENTRAL HEATING) Models
M060S, M090S, M120S, M160S
Appliance Type
Wall-Mounted, Gas-Fired Solo Boiler
Installation
Indoor
Gas Types
Natural Gas (or Propane with field conversion)
Standard Features
• • • • • •
Included with Purchase
• • • • • • • • • • •
Optional Accessories
Closely Spaced Tee/Manifold Kit, Flue Gas Temperature Sensor, Condensate Neutralizer, ScaleCutter, ScaleCutter Refill Cartridge, and Boiler Toolkit
Venting Options
• Direct Vent (Concentric and Twin Pipe) • Room Air • Materials: Polypropylene, Stainless Steel, PVC, CPVC
Measurements: in. (mm)
4.44 (113)
4.25 (108)
1.62 (41)
3.74 (95)
0.39 (10)
27.56 (700)
Factory Installed Modulating Pump Outdoor Reset Control System with Sensor Modulating Ceramic Burner Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Approved for Room and Closet Installations
Condensing Gas Boiler with Integrated Modulating Pump Liquid Propane Field Conversion Kit Wall Mounting Bracket Pressure Relief Valve Condensate Collector Kit Outdoor Reset Sensor Vent Top with Integrated 3 in. (80 mm) PP Adapters 3 in. (80 mm) PP to 3" PVC Adapter (Qty 2) 3 in. PVC to 2 in. PVC or 2 in. (60 mm) PP Adapter (Qty 2) 3 in. X 5 in. Concentric Vent Adapter NPT Adapters: − 1 in. (Qty 2) − 3/4 in. (Qty 1 for Gas Supply Connection) • Documentation: Installation and Operation Manual, User Manual, and ISCL (Installation, Service, and Commissioning Log)
Maximum Equivalent Vent Lengths Twin Pipe and Room Air: Vent Sizes Boiler Model
2 in. PVC and 2 in. (60 mm) PP 3 in. PVC and 3 in. (80 mm) PP M060S, M120S, M060S, M120S, M090S M160S M090S M160S Vent Lengths 60 ft (18 m) 30 ft (9 m) 150 ft (46 m) 140 ft (43 m)
10.46 (266)
17.32 (440)
Gas
Concentric: Vent Sizes Boiler Model Vent Lengths
2 in. X 4 in. M060S, M120S, M090S M160S 60 ft (18 m) 30 ft (9 m)
3 in. X 5 in. M060S, M120S, M090S M160S 150 ft (46 m) 140 ft (43 m)
45° elbow equivalent to 3 ft (1 m). 90° elbow equivalent to 6 ft (2 m). 3.98 (101)
Central Heating Supply
Central Heating Return
2.36 (60) 8.66 (220) 14.96 (380)
● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Model Dimensions (w, h, d) Weight
M060S
M090S
Unit
− Convenient mounting
Shipping
75 lb. (34 kg)
81 lb. (37 kg)
bracket − NPT threads for connection points − More flexible venting options − Simplified parameters for commissioning and setup
Direct Electronic Ignition Stainless Steel 7.3 sq ft
11.8 sq ft
(Min - Max) 68° F - 185° F (20° C - 85° C) 1 Gal. (3.8 L)
1.4 Gal. (5.2 L)
Min
NG: 17,000 LP: 31,500
Max
60,000
NG: 23,500 LP: 73,500
90,000
57 MBH (17 kWh)
84 MBH (25 kWh)
160,000
112 MBH (33 kWh)
148 MBH (43 kWh)
Minimum: 14 PSI (97 kPa) Maximum: 45 PSI (310 kPa)
PRV
375 MBH (110 kWh) 30 PSI (207 kPa)
PRV Rating
UPER 15-78
Sound Level Normal
39 dB
42 dB
155 W
177 W
Standby Max Current
1.62 Amps
164 W
191 W
1.8 Amps
1.67 Amps
1.97 Amps
5 Amps
Clearances
− − − − − −
Top: 2 in. (51 mm)* Bottom: 12 in. (305 mm) Front: 6 in. (152 mm)** Back: 0 in. Sides: 2 in. (51 mm) Vent: 0 in. * 0 in. from vent components. 6 in. (152 mm) for closet installations. ** Clearance for servicing is 24 in. (610 mm) in front of boiler.
8.0 in. - 13.5 in. W.C. (19.9 - 33.6 mbar)
Propane
Electric Voltage
Warranty
AC 120 V, 60 Hz.
Electric Voltage Controls
Residential: −Heat Exchanger: 12 Years
24 V
Circuit Breaker Rating
ENERGY STAR® Certification
54 dB
3.0 in. - 10.5 in. W.C. (7.5 - 26 mbar)
Natural Gas
Turndown Ratio (TDR) Available Pressure Drop at Maximum Input Rate AFUE
48 dB 3.5 W
Fuse
Certifications
120,000
CH
Pump Model
1
design
70 lb. (32 kg)
Temperature Setting
Gas Supply Pressure1
− Compact & lightweight
64 lb. (29 kg)
Heat Exchanger Surface Area
Electrical Data
Faster, Easier Installation
Unit
Heat Exchanger Material
Water Supply Pressure
M160S
12 in. x 23 in. x 31.5 in. (305 mm x 585 mm x 800 mm)
Shipping
Ignition System
Water Content Gas Consumption (Btu/h) Heating Capacity
M120S
17 in. x 28 in. x 10 in. (439 mm x 699 mm x 264 mm)
15 A (Recommended) 3.5:1 / 1.9:1
5.3:1 / 2.9:1
5.1:1 / 1.6:1
6.8:1 / 2.2:1
21.1 ft at 3.2 GPM
16.9 ft at 4.8 GPM
9.5 ft at 6.3 GPM
4.8 ft at 7.5 GPM
95.0% Yes. Recognized as the Most Efficient of ENERGY STAR® 2018 ANSI Z21.13, CSA 4.9
Maximum gas supply pressure must not exceed the value specified by the manufacturer.
−All Other Parts/ Components: 2 Years
−Labor: 1 Year Commercial: − Heat Exchanger: 5 Years
− All Other Parts/ Components: 2 Years
− Labor: 1 Year Important
− If the boiler is to be installed in a system that has multiple zones, a Closely Spaced Tee/ Manifold Kit is recommended to be installed.
− If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator, a Closely Spaced Tee/Manifold Kit must be used. CH = Central Heating PRV = Pressure Relief Valve
CONDENSING WALL-MOUNTED, GAS-FIRED SOLO BOILER (CENTRAL HEATING) Models
M060S, M090S, M120S, M160S
Appliance Type
Wall-Mounted, Gas-Fired Solo Boiler
Installation
Indoor
Gas Types
Natural Gas (or Propane with field conversion)
Standard Features
• • • • • •
Included with Purchase
• • • • • • • • • • •
Optional Accessories
Closely Spaced Tee/Manifold Kit, Flue Gas Temperature Sensor, Condensate Neutralizer, ScaleCutter, ScaleCutter Refill Cartridge, and Boiler Toolkit
Venting Options
• Direct Vent (Concentric and Twin Pipe) • Room Air • Materials: Polypropylene, Stainless Steel, PVC, CPVC
Measurements: in. (mm)
4.44 (113)
4.25 (108)
1.62 (41)
3.74 (95)
0.39 (10)
27.56 (700)
Factory Installed Modulating Pump Outdoor Reset Control System with Sensor Modulating Ceramic Burner Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Approved for Room and Closet Installations
Condensing Gas Boiler with Integrated Modulating Pump Liquid Propane Field Conversion Kit Wall Mounting Bracket Pressure Relief Valve Condensate Collector Kit Outdoor Reset Sensor Vent Top with Integrated 3 in. (80 mm) PP Adapters 3 in. (80 mm) PP to 3" PVC Adapter (Qty 2) 3 in. PVC to 2 in. PVC or 2 in. (60 mm) PP Adapter (Qty 2) 3 in. X 5 in. Concentric Vent Adapter NPT Adapters: − 1 in. (Qty 2) − 3/4 in. (Qty 1 for Gas Supply Connection) • Documentation: Installation and Operation Manual, User Manual, and ISCL (Installation, Service, and Commissioning Log)
Maximum Equivalent Vent Lengths Twin Pipe and Room Air: Vent Sizes Boiler Model
2 in. PVC and 2 in. (60 mm) PP 3 in. PVC and 3 in. (80 mm) PP M060S, M120S, M060S, M120S, M090S M160S M090S M160S Vent Lengths 60 ft (18 m) 30 ft (9 m) 150 ft (46 m) 140 ft (43 m)
10.46 (266)
17.32 (440)
Gas
Concentric: Vent Sizes Boiler Model Vent Lengths
2 in. X 4 in. M060S, M120S, M090S M160S 60 ft (18 m) 30 ft (9 m)
3 in. X 5 in. M060S, M120S, M090S M160S 150 ft (46 m) 140 ft (43 m)
45° elbow equivalent to 3 ft (1 m). 90° elbow equivalent to 6 ft (2 m). 3.98 (101)
Central Heating Supply
Central Heating Return
2.36 (60) 8.66 (220) 14.96 (380)
● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Model Dimensions (w, h, d) Weight
M060S
M090S
Unit
− Convenient mounting
Shipping
75 lb. (34 kg)
81 lb. (37 kg)
bracket − NPT threads for connection points − More flexible venting options − Simplified parameters for commissioning and setup
Direct Electronic Ignition Stainless Steel 7.3 sq ft
11.8 sq ft
(Min - Max) 68° F - 185° F (20° C - 85° C) 1 Gal. (3.8 L)
1.4 Gal. (5.2 L)
Min
NG: 17,000 LP: 31,500
Max
60,000
NG: 23,500 LP: 73,500
90,000
57 MBH (17 kWh)
84 MBH (25 kWh)
160,000
112 MBH (33 kWh)
148 MBH (43 kWh)
Minimum: 14 PSI (97 kPa) Maximum: 45 PSI (310 kPa)
PRV
375 MBH (110 kWh) 30 PSI (207 kPa)
PRV Rating
UPER 15-78
Sound Level Normal
39 dB
42 dB
155 W
177 W
Standby Max Current
1.62 Amps
164 W
191 W
1.8 Amps
1.67 Amps
1.97 Amps
5 Amps
Clearances
− − − − − −
Top: 2 in. (51 mm)* Bottom: 12 in. (305 mm) Front: 6 in. (152 mm)** Back: 0 in. Sides: 2 in. (51 mm) Vent: 0 in. * 0 in. from vent components. 6 in. (152 mm) for closet installations. ** Clearance for servicing is 24 in. (610 mm) in front of boiler.
8.0 in. - 13.5 in. W.C. (19.9 - 33.6 mbar)
Propane
Electric Voltage
Warranty
AC 120 V, 60 Hz.
Electric Voltage Controls
Residential: −Heat Exchanger: 12 Years
24 V
Circuit Breaker Rating
ENERGY STAR® Certification
54 dB
3.0 in. - 10.5 in. W.C. (7.5 - 26 mbar)
Natural Gas
Turndown Ratio (TDR) Available Pressure Drop at Maximum Input Rate AFUE
48 dB 3.5 W
Fuse
Certifications
120,000
CH
Pump Model
1
design
70 lb. (32 kg)
Temperature Setting
Gas Supply Pressure1
− Compact & lightweight
64 lb. (29 kg)
Heat Exchanger Surface Area
Electrical Data
Faster, Easier Installation
Unit
Heat Exchanger Material
Water Supply Pressure
M160S
12 in. x 23 in. x 31.5 in. (305 mm x 585 mm x 800 mm)
Shipping
Ignition System
Water Content Gas Consumption (Btu/h) Heating Capacity
M120S
17 in. x 28 in. x 10 in. (439 mm x 699 mm x 264 mm)
15 A (Recommended) 3.5:1 / 1.9:1
5.3:1 / 2.9:1
5.1:1 / 1.6:1
6.8:1 / 2.2:1
21.1 ft at 3.2 GPM
16.9 ft at 4.8 GPM
9.5 ft at 6.3 GPM
4.8 ft at 7.5 GPM
95.0% Yes. Recognized as the Most Efficient of ENERGY STAR® 2018 ANSI Z21.13, CSA 4.9
Maximum gas supply pressure must not exceed the value specified by the manufacturer.
−All Other Parts/ Components: 2 Years
−Labor: 1 Year Commercial: − Heat Exchanger: 5 Years
− All Other Parts/ Components: 2 Years
− Labor: 1 Year Important
− If the boiler is to be installed in a system that has multiple zones, a Closely Spaced Tee/ Manifold Kit is recommended to be installed.
− If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator, a Closely Spaced Tee/Manifold Kit must be used. CH = Central Heating PRV = Pressure Relief Valve
E50CR Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water Standard Built-in Domestic Hot Water Plate Heat Exchanger Modulating Ceramic Premix Burner 3.7:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Twin Pipe Venting Standard Approved For Room and Closet Installations (Zero Clearance to Combustibles)
RS100 Single Zone Controller Flue Gas Temperature Sensor Twin Pipe to Concentric Vent Adapters Room Air Filter NG to LP Conversion Kit Flow Switch Conversion Kit Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
0.9 Gal / 3.4 L
Fuel Type
Max. Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
50 MBH / 14.7 kWh
Heating Capacity
47 MBH / 13.8 kWh
Input (DHW)
85 MBH / 24.9 kWh
Minimum Input
13.6 MBH / 4.0 kWh
Turndown Ratio
3.7:1 TDR
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
45 psi / 310 kPa 375 MBH / 110 kWh 30 psi / 207 kPa 81 lbs / 37 kg
Min Inlet Gas Pressure NG
3.0" WC / 7.5 mbar
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
Electrical Voltage Mains Electrical Voltage Controls
NG
120 V / 60 Hz
System Pump Model Max Head Pressure at Flow Rate
24 V
UPER 20-58 6.7 ft at 5.0 GPM 2.0 m at 18.9 LPM
Power Consumption Max Load
145 W
AFUE
Power Consumption Standby Load
14 W
DHW Flow Rate 75°F ΔT
2.1 GPM / 7.9 LPM
Recommended Circuit Breaker Rating
15 A
DHW Minimum Activation
0.5 GPM / 2.0 LPM
Sound Level
39 dB Flow Restrictor Color
95.6%
Brown
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
E50CR-SP-2
8/2017
E50CR Condensing Boiler DIMENSIONS
Additional Information:
If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.
If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.
If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.
Shipping Specifications:
Shipping Weight: 93 lbs (42 Kg)
Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)
A
Height
25.6” / 650 mm
B
Width
19.7” / 500 mm
C
Depth
15.6” / 395 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to Center / Vent and Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
9.8” / 250 mm
H
Left Side / Supply Pipe
5.9” / 150 mm
J
Left Side / Return Pipe
13.8” / 350 mm
K
Left Side / Condensate Pipe
15.9” / 405 mm
N
Left Side / Cold water Pipe
11.2” / 285 mm
O
Left Side / Hot Water Pipe
8.5” / 215 mm
P
Pipe Length of G
1” / 26 mm
Q
Pipe Length of C
1.6” / 40 mm
R
Pipe length of F, K, R, and W
3.5” / 90 mm
S
Back / Center of Pipes C, K, and W
1” / 26 mm
T
Back / Center of Pipes F, G, and R
1.9” / 49 mm
V
Pipe Length Vent Co-axial Pipe Length Vent Parallel
3.7” / 95 mm 7” / 177 mm
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
0
10” / 250 mm
Back
0
0
Front
1” / 25 mm
24” / 600 mm
Left Side
0
2” / 50 mm
Right Side
0
2” / 50 mm
Floor / Ground
0
12” / 300 mm
Vent
0
0
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
E50CR-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
E60SR Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Integrated Control for External Domestic Hot Water Indirect Tank Modulating Ceramic Premix Burner 4.4:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Concentric Venting System Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)
RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit DHW Indirect Tank Temperature Sensor
SPECIFICATIONS Performance Specifications
General Specifications Water Content
0.9 Gal / 3.4 L
Max. Supply Boiler Temperature
176 °F / 80 °C
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
45 psi / 310 kPa 375 MBH / 110 kWh 30 psi / 207 kPa 75 lbs / 34 kg
Min Inlet Gas Pressure NG
4.0" WC / 10.0 mbar
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
Electrical Voltage Mains Electrical Voltage Controls
120 V / 60 Hz 24 V
Power Consumption Max Load
145 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
39 dB
Fuel Types
NG and LP
Input (Heating)
60 MBH / 17.6 kWh
Heating Capacity
56 MBH / 16.4 kWh
Input (Domestic Hot Water) Minimum Input Turndown Ratio System Pump Model Max Head Pressure at Flow Rate AFUE
N/A NG: 13.6 MBH / 4.0 kWh LP: 37.0 MBH / 10.9 kWh 4.4:1 / 1.6:1 TDR UPER 20-58 7.3 ft at 5.0 GPM 2.2 m at 18.9 LPM 95.5%
DHW Flow Rate 75°F ΔT
N/A
DHW Minimum Activation
N/A
Flow Restrictor Color
N/A
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
E60SR-SP-2
8/2017
E60SR Condensing Boiler DIMENSIONS
Connection for combustion air supply and vent system A
Height
25.6” / 650 mm
B
Width
19.7” / 500 mm
C
Depth
15.6” / 395 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to Center / Vent & Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
9.8” / 250 mm
H
Left Side / Supply Pipe
5.9” / 150 mm
J
Left Side / Return Pipe
13.8” / 350 mm
K
Left Side / Condensate Pipe
15.9” / 405 mm
P
Pipe Length of G
1” / 26 mm
Q
Pipe Length of C
1.6” / 40 mm
S
Back / Center of Pipe C
T
Back / Center of Pipe F, G, and R
1.9” / 49 mm
V
Pipe Length Concentric Vent and Air Supply
7” / 177 mm
1” / 26 mm
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left side
2” / 50 mm
2” / 50 mm
Right side
2” / 50 mm
2” / 50 mm
Floor / Ground
0
12” / 300 mm
Vent
0
0
Additional Information:
If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed. If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used. If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.
Shipping Specifications:
Shipping Weight: 86 lbs (39 Kg)
Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
E60SR-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
E75CR Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water Standard Built-in Domestic Hot Water Plate Heat Exchanger Modulating Ceramic Premix Burner 5.5:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)
RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Flow Switch Conversion Kit Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
0.9 Gal / 3.4 L
Fuel Types
Max. Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
75 MBH / 22.0 kWh
Heating Capacity
69 MBH / 20.2 kWh
Input (DHW)
85 MBH / 24.9 kWh
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
45 PSI/ 310 kPa 375 MBH/ 110 kWh 30 PSI / 207 kPa 82 lbs / 37 kg
Minimum Input
Min Inlet Gas Pressure NG
4.0" WC / 10.0 mbar
Turndown Ratio
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
Electrical Voltage Mains Electrical Voltage Controls
NG and LP
120 V / 60 Hz 24 V
Power Consumption Max Load
145 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
39 dB
System Pump Model Max Head Pressure at Flow Rate AFUE
NG: 13.6 MBH / 4.0 kWh LP: 37.0 MBH / 10.9 kWh 5.5:1 / 2.0:1 TDR UPER 20-58 6.7 ft at 5.0 GPM 2.0 m at 18.9 LPM 95.5%
DHW Flow Rate 75°F ΔT
2.1 GPM / 7.9 LPM
DHW Minimum Activation
0.5 GPM / 2.0 LPM
Flow Restrictor Color
Brown
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
E75CR-SP-2
8/2017
E75CR Condensing Boiler DIMENSIONS Connection for combustion air supply and vent system
A
Height
25.6” / 650 mm
B
Width
19.7” / 500 mm
C
Depth
15.6” / 395 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to Center / Vent and Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
9.8” / 250 mm
H
Left Side / Supply Pipe
5.9” / 150 mm
J
Left Side / Return Pipe
13.8” / 350 mm
K
Left Side / Condensate Pipe
15.9” / 405 mm
N
Left Side / Cold Water Pipe
11.2” / 285 mm
O
Left Side / Hot Water Pipe
8.5” / 215 mm
P
Pipe Length of G
1” / 26 mm
Q
Pipe Length of C
1.6” / 40 mm
R
Pipe Length of F, K, R, and W
3.5” / 90 mm
S
Back / Center of Pipes C, K, and E
1” / 26 mm
T
Back / Center of Pipes F, G, and R
1.9” / 49 mm
V
Pipe Length Vent Co-axial Pipe Length Vent Parallel
3.7” / 95 mm 7” / 177 mm
Additional Information:
If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.
If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.
Clearances
If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.
Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Shipping Specifications:
Right Side
2” / 50 mm
2” / 50 mm
Shipping Weight: 94 lbs (43 Kg)
Floor / Ground
12” / 300 mm
12” / 300 mm
Shipping Dimensions: 34”x17”x22” (86 cm x 44 cm x 55 cm)
0
0
Vent
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
E75CR-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
E85SR Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Integrated Control for External Domestic Hot Water Indirect Tank Modulating Ceramic Premix Burner 6.25:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Concentric Venting System Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)
RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit DHW Indirect Tank Temperature Sensor
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
0.9 GAL / 3.4 L
Fuel Types
Max. Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
85 MBH / 24.9 kWh
Heating Capacity
78 MBH / 22.9 kWh
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight Min Inlet Gas Pressure NG
45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa 75 lbs / 34 kg
Input (DHW) Minimum Input
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
System Pump Model
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Head Pressure at Flow Rate
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
AFUE
Electrical Voltage Controls
N/A NG: 13.6 MBH / 4.0 kWh LP: 37.0 MBH / 10.9 kWh
4.0" WC / 10.0 mbar Turndown Ratio
Electrical Voltage Mains
NG and LP
120 V / 60 Hz
6.25:1 / 2.3:1 TDR UPER 20-58 7.3 ft at 5.0 GPM 2.2 m at 18.9 LPM 95.4%
DHW Flow Rate 75°F ΔT
N/A
DHW Minimum Activation
N/A
Flow Restrictor Color
N/A
24 V
Power Consumption Max Load
145 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
39 dB
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
E85SR-SP-2
8/2017
E85SR Condensing Boiler DIMENSIONS
Connection for combustion air supply and vent system
Height
25.6” / 650 mm
B
Width
19.7” / 500 mm
C
Depth
15.6” / 395 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to Center / Vent and Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
9.8” / 250 mm
H
Left Side / Supply Pipe
5.9” / 150 mm
J
Left Side / Return Pipe
13.8” / 350 mm
K
Left Side / Condensate Pipe
15.9” / 405 mm
P
Pipe Length of G
1” / 26 mm
Q
Pipe Length of C
1.6” / 40 mm
S
Back / Center of Pipe C
T
Back / Center of Pipes F, G, and R
1.9” / 49 mm
V
Pipe Length Concentric Vent and Air Supply
7” / 177 mm
1” / 26 mm
Clearances
Additional Information:
If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.
If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.
A
If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.
Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Right Side
2” / 50 mm
2” / 50 mm
12” / 300 mm
12” / 300 mm
0
0
Floor / Ground Vent
Shipping Specifications:
Shipping Weight: 86 lbs (39 Kg)
Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
E85SR-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
E110SR Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Integrated Control for External Domestic Hot Water (DHW) Indirect Tank Modulating Ceramic Premix Burner 4.2:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Concentric Venting System Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)
RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit DHW Indirect Tank Temperature Sensor
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
1.3 Gal / 4.8 L
Fuel Types
NG and LP
Max. Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
110 MBH / 32.2 kWh
45 PSI / 310 kPa
Heating Capacity
101 MBH / 29.6 kWh
Input (DHW)
N/A
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight Min Inlet Gas Pressure NG
375 MBH/ 110 kWh 30 PSI / 207 kPa 81 lbs / 37 kg 4.0" / 10.0 mbar
Max Inlet Gas Pressure NG
10.5"/26.2 mbar
Min Inlet Gas Pressure LP
8.0" / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” / 33.6 mbar
Electrical Voltage Mains Electrical Voltage Controls
120 V / 60 Hz 24 V
Power Consumption Max Load
145 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
49 dB
Minimum Input
NG: 26 MBH / 7.6 kWh LP: 59 MBH / 17.4 kWh
Turndown Ratio
4.2:1 / 1.9:1TDR
System Pump Model
UPER 20-78
Max Head Pressure at Flow Rate
14.2 ft at 5.0 GPM 4.3 m at 18.9 LPM
AFUE
95.5%
DHW Flow Rate 75°F ΔT
N/A
DHW Minimum Activation
N/A
Flow Restrictor Color
N/A
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
E110SR-SP-2
8/2017
E110SR Condensing Boiler DIMENSIONS
Connection for combustion air supply and vent system
A
Height
25.6” / 650 mm
B
Width
19.7” / 500 mm
C
Depth
15.6” / 395 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to Center / Vent and Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
9.8” / 250 mm
H
Left Side / Supply Pipe
5.9” / 150 mm
J
Left Side / Return Pipe
13.8” / 350 mm
K
Left Side / Condensate Pipe
15.9” / 405 mm
P
Pipe Length of G
1” / 26 mm
Q
Pipe Length of C
1.6” / 40 mm
S
Back / Center of Pipe C
T
Back / Center of Pipes F, G, and R
1.9” / 49 mm
V
Pipe Length Concentric Vent and Air Supply
7” / 177 mm
1” / 26 mm
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Right Side
2” / 50 mm
2” / 50 mm
If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.
Floor / Ground
12” / 300 mm
12” / 300 mm
0
0
Additional Information:
If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.
Vent
Shipping Specifications:
Shipping Weight: 92 lbs (42 Kg)
Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
E110SR-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
E110CR Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard Built-in DHW Plate Heat Exchanger Modulating Ceramic Premix Burner 4.2:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)
RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Flow Switch Conversion Kit Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
1.3 Gal / 4.8 L
Fuel Types
NG and LP
Max. Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
110 MBH / 32.2 kWh
45 PSI / 310 kPa
Heating Capacity
101 MBH / 29.6 kWh
375 MBH / 110 kWh
Input (DHW)
130 MBH / 38.1 kWh
Minimum Input
NG: 26 MBH / 7.6 kWh LP: 59 MBH / 17.4 kWh
Turndown Ratio
4.2:1 / 1.9:1 TDR
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
30 PSI / 207 kPa 92 lbs / 42 kg
Min Inlet Gas Pressure NG
4.0" WC / 10.0 mbar
System Pump Model
UPER 20-78
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Max Head Pressure at Flow Rate
13.8 ft at 5.0 GPM 4.2 m at 18.9 LPM
Min Inlet Gas Pressure LP
8.00" WC / 19.9 mbar
AFUE
95.5%
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
DHW Flow Rate 75°F ΔT
3.2 GPM / 12.1 LPM
DHW Minimum Activation
0.5 GPM / 2.0 LPM
Flow Restrictor Color
Green
Electrical Voltage Mains Electrical Voltage Controls
120 V / 60 Hz 24 V
Power Consumption Max Load
145 W
Power Consumption Standby Load
14 W
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Recommended Circuit Breaker Rating
15 A
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Sound Level
49 dB Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
E110CR-SP-2
8/2017
E110CR Condensing Boiler DIMENSIONS Connection for combustion air supply and vent system
A
Height
25.6” / 650 mm
B
Width
19.7” / 500 mm
C
Depth
15.6” / 395 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to center / Vent and Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
9.8” / 250 mm
H
Left Side / Supply Pipe
5.9” / 150 mm
J
Left Side / Return Pipe
13.8” / 350 mm
K
Left Side / Condensate Pipe
15.9” / 405 mm
N
Left Side / Cold Water Pipe
11.2” / 285 mm
O
Left Side / Hot Water Pipe
8.5” / 215 mm
P
Pipe Length of G
1” / 26 mm
Q
Pipe Length of C
1.6” / 40 mm
R
Pipe Length of F, K, R, and W
3.5” / 90 mm
S
Back / Center of Pipes C, K, and W
1” / 26 mm
T
Back / Center of Pipes F, G, and R
1.9” / 49 mm
V
Pipe Length Vent Co-axial Pipe Length Vent Parallel
3.7” / 95 mm 7” / 177 mm
Additional Information:
If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed. If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used. If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Right Side
2” / 50 mm
2” / 50 mm
12” / 300 mm
12” / 300 mm
0
0
Floor / Ground Shipping Specifications:
Shipping Weight: 104 lbs (47 Kg)
Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)
Vent
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
E110CR-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
Q130S Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard (with Optional 3-way Valve, Not Included) Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations
3-way Valve DHW Kit RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
1.3 Gal / 5.0 L
Fuel Types
Max Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
130 MBH / 38.0 kWh
Heating Capacity
119 MBH / 34.9 kWh
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight Min Inlet Gas Pressure NG
45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa 117 lbs / 53 kg
Input (DHW) Minimum Input
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
System Pump Model
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Head Pressure at Flow Rate
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
AFUE
Electrical Voltage Controls
N/A NG: 26.0 MBH / 7.6 kWh LP: 59.0 MBH / 17.3 kWh
4.0" WC / 10.0 mbar Turndown Ratio
Electrical Voltage Mains
NG and LP
120 V / 60 Hz
5.0:1 / 2.2:1 TDR UPER 20-78 16.4 ft at 5.0 GPM 5.0 m at 18.9 LPM 95.4%
DHW Flow Rate 75°F ΔT
N/A
DHW Minimum Activation
N/A
Flow Restrictor Color
N/A
24 V
Power Consumption Max Load
144 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
50 dB
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
Q130S-SP-2
8/2017
Q130S Condensing Boiler DIMENSIONS
A
Height
26.8” / 680 mm
B
Width
19.7” / 500 mm
C
Depth
15.2” / 385 mm
D
Left Side / Vent
13.2” / 335 mm
E
Center to Center/Vent and Air Supply
4.7” / 120 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
2.6” / 65 mm
H
Left Side / Supply Pipe
7.8” / 199 mm
J
Left Side / Return Pipe
16.8” / 428 mm
K
Left Side / Condensate Pipe
14.6” / 370 mm
P
Pipe Length of G
0.7” / 18 mm
Q
Pipe Length of C
2” / 50 mm
R
Pipe Length of F and R
17.7” / 450 mm
T
Back / Center of Pipe C
1” / 25 mm
U
Back / Center of Pipe G
1.6” / 40 mm
V1 Back / Center of Pipes f1 and r1
2” / 50 mm
V2 Back / Center of Pipes f2 and r2
2.1” / 54 mm
W
Pipe Length Vent Co-axial Pipe Length Vent Parallel
2.6” / 65 mm 5.8” / 147 mm
X
Bottom Side Boiler to Center Pressure Relief Valve
7.7” / 195 mm
Y
Bottom Side Boiler to Center Low Loss Header
10.2” / 260 mm
Z
Center to Center of f2 to r2
9” / 229 mm
aa
Depth of Low Loss Header
5.6” / 142 mm
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Right Side
2” / 50 mm
2” / 50 mm
12” / 300 mm
30” / 762 mm
Floor / Ground to Bottom of Low Loss Header
0
12” / 300 mm
Vent
0
0
Floor / Ground
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
Q130S-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
Q175S Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard (with Optional 3-way Valve, Not Included) Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations
3-way Valve DHW Kit RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
1.8 Gal / 7.0 L
Fuel Types
Max Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
175 MBH / 51.0 kWh
Heating Capacity
162 MBH / 47.5 kWh
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa 141 lbs / 64 kg
Input (DHW) Minimum Input
Min Inlet Gas Pressure NG
4.0" WC / 10.0 mbar
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
System Pump Model
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Head Pressure at Flow Rate
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
AFUE
Electrical Voltage Mains Electrical Voltage Controls
NG and LP
120 V / 60 Hz 24 V
Power Consumption Max Load
210 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
54 dB
Turndown Ratio
N/A NG: 35 MBH / 10.3 kWh LP: 74 MBH / 21.7 kWh 5.0:1 / 2.4:1 TDR UPER 20-78 16.4 ft at 5.0 GPM 5.0 m at 18.9 LPM 95.0%
DHW Flow Rate 75°F ΔT
N/A
DHW Minimum Activation
N/A
Flow Restrictor Color
N/A
Max Equivalent Exhaust Vent Length
80 ft / 24.4 m
Max Equivalent Combustion Air Vent Length
80 ft / 24.4 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
Q175S-SP-2
8/2017
Q175S Condensing Boiler DIMENSIONS
A
Height
26.8” / 680 mm
B
Width
26” / 660 mm
C
Depth
15.2” / 385 mm
D
Left Side / Vent
19.5” / 495 mm
E
Center to Center / Vent and Air Supply
4.7” / 121 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
2.6” / 65 mm
H
Left Side / Supply Pipe
7.8” / 199 mm
J
Left Side / Return Pipe
19.8” / 504 mm
K
Left Side / Condensate Pipe
20.9” / 530 mm
P
Pipe Length of G
0.7” / 18 mm
Q
Pipe Length of C
2” / 50 mm
R
Pipe Length of F and R
18.5” / 470 mm
T
Back / Center of Pipe C
1” / 25 mm
U
Back / Center of Pipe G
1.6” / 40 mm
V1 Back / Center of Pipes f1 and r1
2” / 50 mm
V2 Back/ Center of Pipes f2 and r2
2.1” / 54 mm
W
Pipe Length Vent Co-axial Pipe Length Vent Parallel
2.6” / 65 mm 5.8” / 147 mm
X
Bottom Side Boiler to Center Pressure Relief Valve
7.7” / 195 mm
Y
Bottom Side Boiler to Center Low Loss Header
10.2” / 260 mm
Z
Center to Center f2 to r2
aa
Depth of Low Loss Header
9” / 229 mm 5.6” / 142 mm
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Right Side
2” / 50 mm
2” / 50 mm
12” / 300 mm
30” / 762 mm
Floor / Ground to Bottom of Low Loss Header
0
12” / 300 mm
Vent
0
0
Floor / Ground
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
Q175S-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
Q175C Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard Built in DHW 6.6 Gallon Indirect Tank Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations
RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content (Heating)
1.8 Gal / 7.0 L
Water Content (DHW)
3.7 Gal / 14 L
Max Supply Boiler Temperature
176 °F / 80 °C
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
375 MBH / 110 kWh 30 PSI / 207 kPa
Input (Heating)
175 MBH / 51.0 kWh
Heating Capacity
162 MBH / 47.5 kWh
Input (DHW)
175 MBH / 51.0 kWh
Minimum Input
196 lbs / 89 kg 4.0" WC / 10.0 mbar
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
Electrical Voltage Controls
NG and LP
45 PSI / 310 kPa
Min Inlet Gas Pressure NG
Electrical Voltage Mains
Fuel Types
Turndown Ratio System Pump Model Max Head Pressure at Flow Rate AFUE
NG: 35 MBH / 10.3 kWh LP: 74 MBH / 21.7 kWh 5.0:1 / 2.4:1 TDR UPER 20-78 15.9 ft at 5.0 GPM 4.8 m at 18.9 LPM 95.0%
DHW Flow Rate 75°F ΔT
4.1 GPM / 15.5 LPM
DHW Minimum Activation
N/A N/A
120 V / 60 Hz 24 V
Power Consumption Max Load
210 W
Flow Restrictor Color
Power Consumption Standby Load
14 W
80 ft / 24.4 m
Recommended Circuit Breaker Rating
Max Equivalent Exhaust Vent Length
15 A
80 ft / 24.4 m
Sound Level
54 dB
Max Equivalent Combustion Air Vent Length Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
Q175C-SP-2
8/2017
Q175C Condensing Boiler DIMENSIONS
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left side
2” / 50 mm
2” / 50 mm
Right side
2” / 50 mm
2” / 50 mm
12” / 300 mm
30” / 762 mm
Floor / Ground to bottom of Low Loss Header
0
12” / 300 mm
Vent
0
0
Floor / Ground
A
Height
26.8” / 680 mm
B
Width
39.4” / 1000 mm
C
Depth
15.2” / 385 mm
D
Left Side / Vent
19.5” / 495 mm
E
Center to Center / Vent and Air Supply
4.7” / 121 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
2.6” / 65 mm
H
Left Side / Supply Pipe
7.8” / 199 mm
J
Left Side / Return Pipe
19.8” / 504 mm
K
Left Side / Condensate Pipe
20.9” / 530 mm
L
Left Side / Expansion Tank
23.2” / 590 mm
N
Left Side / Cold Water Pipe
34.8” / 885 mm
O
Left Side / Hot Water Pipe
37.6” / 955 mm
P
Pipe Length of G
0.7” / 18 mm
Q
Pipe Length of C
2” / 50 mm
R
Pipe Length of F and R
18.5” / 470 mm
T
Back / Center of Pipe C
1” / 25 mm
U
Back / Center of Pipe G
1.6” / 40 mm
V1
Back / Center of Pipes f1, e, k, r1, and w
2” / 50 mm
V2 Back/ Center of Pipes f2 and r2
2.1” / 54 mm
W
Pipe Length Vent Co-axial Pipe Length Vent Parallel
2.6” / 65 mm 5.8” / 147 mm
X
Bottom Side Boiler to Center Pressure Relief Valve
8” / 200 mm
Y
Bottom Side Boiler to Center Low Loss Header
10.4” / 265 mm
Z
Center to Center of f2 and r2
12” / 305 mm
aa Depth of Low Loss Header
5.6” / 142 mm
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
Q175C-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
Q205S Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard (with Optional 3-way Valve, Not Included) Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations
3-way Valve DHW Kit RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content
1.8 Gal / 7.0 L
Fuel Types
Max Supply Boiler Temperature
176 °F / 80 °C
Input (Heating)
205 MBH / 60.0 kWh
Heating Capacity
186 MBH / 54.5 kWh
Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight
45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa
Input (DHW)
141 lbs / 64 kg
Minimum Input
Min Inlet Gas Pressure NG
4.0" WC / 10.0 mbar
Turndown Ratio
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
Electrical Voltage Mains Electrical Voltage Controls
NG and LP
120 V / 60 Hz 24 V
Power Consumption Max Load
234 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
57 dB
System Pump Model Max Head Pressure at Flow Rate AFUE
N/A NG: 41 MBH / 12.0 kWh LP: 74 MBH / 21.7 kWh 5.0:1 / 2.8:1 TDR UPER 20-78 23.1 ft at 5.0 GPM 7.0 m at 18.9 LPM 95.0%
DHW Flow Rate 75°F ΔT
N/A
DHW Minimum Activation
N/A
Flow Restrictor Color
N/A
Max Equivalent Exhaust Vent Length
40 ft / 12.2 m
Max Equivalent Combustion Air Vent Length
40 ft / 12.2 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
Q205S-SP-2
8/2017
Q205S Condensing Boiler DIMENSIONS
A
Height
26.8” / 680 mm
B
Width
26” / 660 mm
C
Depth
15.2” / 385 mm
D
Left Side / Vent
19.5” / 495 mm
E
Center to Center / Vent and Air Supply
4.7” / 121 mm
F
Back / Vent
10.6” / 270 mm
G
Left Side / Gas Pipe
2.6” / 65 mm
H
Left Side / Supply Pipe
7.8” / 199 mm
J
Left Side / Return Pipe
19.8” / 504 mm
K
Left Side / Condensate Pipe
20.9” / 530 mm
P
Pipe Length of G
0.7” / 18 mm
Q
Pipe Length of C
2” / 50 mm
R
Pipe Length of F and R
18.5” / 470 mm
T
Back / Center of Pipe C
1” / 25 mm
U
Back / Center of Pipe G
1.6” / 40 mm
V1 Back / Center of Pipes f1 and r1
2” / 50 mm
V2 Back/ Center of Pipes f2 and r2
2.1” / 54 mm
W
Pipe Length Vent Co-axial Pipe Length Vent Parallel
2.6” / 65 mm 5.8” / 147 mm
X
Bottom Side Boiler to Center Pressure Relief Valve
7.7” / 195 mm
Y
Bottom Side Boiler to Center Low Loss Header
10.2” / 260 mm
Z
Center to Center f2 to r2
aa
Depth of Low Loss Header
9” / 229 mm 5.6” / 142 mm
Clearances Minimum required clearance to combustibles and non-combustibles
Recommended service clearances
Top
2” / 50 mm
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
2” / 50 mm
2” / 50 mm
Right Side
2” / 50 mm
2” / 50 mm
12” / 300 mm
30” / 762 mm
Floor / Ground to Bottom of Low Loss Header
0
12” / 300 mm
Vent
0
0
Floor / Ground
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
Q205S-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
QP130 Condensing Boiler Standard Features
Optional Accessories
Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Factory Installed Low Loss Header Priority Domestic Hot Water (DHW) Standard 24 Gallon Charged Indirect Stainless Steel Storage Tank Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations Pre-piped to Accept a DHW Recirculation Line
Room Air Filter NG to LP Conversion Kit
Piping Options
Right Side Pre-bend Piping Kit Left Side Pre-bend Piping Kit Top Side Pre-bend Piping Kit
SPECIFICATIONS General Specifications
Performance Specifications
Water Content (Heating)
1.3 Gal / 5 L
Water Content (DHW)
24 Gal / 90 L
Max Supply Boiler Temperature
176 °F / 80 °C
Max Operating Pressure Relief Valve Rating
375 MBH / 110 kWh 30 PSI / 207 kPa
Unit Weight
243 lbs / 110 kg
Min Inlet Gas Pressure NG
4.0" WC / 10.0 mbar
Max Inlet Gas Pressure NG
10.5" WC / 26.2 mbar
Min Inlet Gas Pressure LP
8.0" WC / 19.9 mbar
Max Inlet Gas Pressure LP
13.5” WC / 33.6 mbar
Electrical Voltage Controls
NG and LP
Input (Heating)
130 MBH / 38.0 kWh
Heating Capacity
119 MBH / 34.3 kWh
Input (DHW)
130 MBH / 38.0 kWh
45 PSI / 310 kPa
Relief Valve Pressure Rating
Electrical Voltage Mains
Fuel Types
120 V / 60 Hz
Minimum Input Turndown Ratio System Pump Model AFUE DHW Flow Rate 75°F ΔT
10 Minute Peak Flow (75°F ΔT) DHW Minimum Activation
NG: 26.0 MBH / 7.6 kWh LP: 59.0 MBH / 17.3 kWh 5.0:1 / 2.2:1 TDR UPER 20-78 95.4% 3.2 GPM / 12.1 LPM 56 Gal / 212 L N/A
24 V
Power Consumption Max Load
176 W
Power Consumption Standby Load
14 W
Recommended Circuit Breaker Rating
15 A
Sound Level
50 dB
First Hour Rating Flow Restrictor Color
211 GPH / 799 LPH N/A
Max Equivalent Exhaust Vent Length
100 ft / 30.5 m
Max Equivalent Combustion Air Vent Length
100 ft / 30.5 m
Approved Venting Materials
Polypropylene, Stainless Steel, PVC, CPVC
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation
QP130-SP-2
8/2017
QP130 Condensing Boiler DIMENSIONS P Q R
P Q R
S F
D
G
A
Height
61.8” / 1570 mm
B
Height Including Vent Connection
64.5” / 1640 mm
C
Width
23.6” / 600 mm
D
Depth
25.2” / 640 mm
E
Center Boiler / Vent
F
Back / Vent
18.5” / 470 mm
G
Center to Center / Vent and Air Supply
4.7” / 122 mm
3.7” / 95 mm
Connection Side: Left and Right E C
A B H
J K L
H
Bottom Side Boiler
Supply Pipe
48.4” / 1230 mm
J
Bottom Side Boiler
Return Pipe
45.7” / 1160 mm
K
Bottom Side Boiler
Hot Water Pipe Gas Pipe
42.9” / 1090 mm
L
Bottom Side Boiler
Cold Water Pipe DHW Circulation Return Pipe
40.2” / 1020 mm
M
Bottom Side Boiler
DHW Circulation Return Pipe Cold Water Pipe
37.4” / 950 mm
N
Bottom Side Boiler
Gas Pipe Hot Water Pipe
34.6” / 880 mm
0
Bottom Side Boiler
Condensate Pipe
26.0” / 662 mm
Connection Side: Top MN
P
Center boiler
Gas Pipe Hot Water Pipe
6.9” / 175 mm
Q
Center boiler
DHW Circulation Return Pipe Cold Water Pipe
4.1” / 105 mm
R
Center boiler
Supply Pipe Return Pipe
1.4” / 35 mm
S
Back boiler
Center of all Pipe Connections
1.2” / 30 mm
O
S
Clearances Minimum required clearance Recommended to combustibles and service clearances non-combustibles Top
0
10” / 250 mm
Back
0
0
Front
6” / 150 mm
24” / 600 mm
Left Side
0
2” / 50 mm
Right Side
0
2” / 50 mm
Vent
0
0
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
© 2017 Rinnai Corporation
QP130-SP-2
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
8/2017
SENSEI™ Commercial Tankless Water Heaters (Condensing) Rinnai Commercial Condensing Tankless Water Heaters are precision-engineered to produce an endless supply of hot water for even the most demanding applications from restaurants to hotels to multi-family residences, schools and more. When the demands are greatest, Rinnai delivers.
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
List Price (U.S.)
CU199iN
Commercial Int CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 31.3
64
199,000
22.1 x 14.8 x 33.9
74
97%
$2,200
CU199iP
Commercial Int CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 31.3
64
199,000
22.1 x 14.8 x 33.9
74
97%
$2,200
CU199eN
Commercial Exterior CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 28.4
64
199,000
22.1 x 14.8 x 33.9
72
97%
$2,200
CU199eP
Commercial Exterior CTWH 199k Btu 11 gpm max w/Valve
18 x 11.4 x 28.4
64
199,000
22.1 x 14.8 x 33.9
72
97%
$2,200
CU160eN
Commercial Exterior CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 28.4
62
160,000
22.1 x 14.8 x 33.9
71
97%
$1,864
CU160eP
Commercial Exterior CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 28.4
62
160,000
22.1 x 14.8 x 33.9
71
97%
$1,864
CU160iN
Commercial Int CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 31.3
62
160,000
22.1 x 14.8 x 33.9
72
97%
$1,864
CU160iP
Commercial Int CTWH 160k Btu 9 gpm max w/Valve
18 x 11.4 x 31.3
62
160,000
22.1 x 14.8 x 33.9
72
97%
$1,864
Model Number
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Demand Duo™ Commercial Hybrid Water Heating Systems Combining the on-demand, continuous-supply technology of the Rinnai Tankless with an energy-efficient and durable 119-gallon and 80-gallon storage tank, the Demand Duo™ provides more water-heating capacity than a traditional tank in the first hour. These systems are perfect for emergency replacement situations with connection locations similar to most popular high-efficiency tanks. Models available include condensing and non-condensing tankless units. CHS199100CU CHS19980 CHS398100CU
Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Tank Capacity/ First Hour Delivery (Gallons)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency (or UEF)
List Price (U.S.)
CHS199100CUiN
Commercial Hybrid, Indoor, Max BTU 199,000, First 30.8 x 34.5 x 69.3 Hour Rating: 315 gph
430
199,000
119/ 315
48 x 37.25 x 78
490
97% (N/A)
$7,600
CHS199100CUiP
Commercial Hybrid, Indoor, Max BTU 199,000, First 30.8 x 34.5 x 69.3 Hour Rating: 315 gph
430
199,000
119/ 315
48 x 37.25 x 78
490
97% (N/A)
$7,600
RHS199100SEiN
Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 315 gph
30.8 x 34.5 x 69.3
430
199,000
119/ 315
48 x 37.25 x 78
490
97% (N/A)
$7,600
RHS199100SEiP
Residential Hybrid, Internal, Max BTU 199,000, First 30.8 x 34.5 x 69.3 Hour Rating: 315 gph
430
199,000
119/ 315
48 x 37.25 x 78
490
97% (N/A)
$7,600
CHS19980HEiN
Commercial Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph
27.7 x 34.1 x 64.7
290
199,000
80/ 259
34 x 24 x 63
450
N/A (0.81)
$5,800
CHS19980HEiP
Commercial Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph
27.7 x 34.1 x 64.7
290
199,000
80/ 259
34 x 24 x 63
450
N/A (0.81)
$5,800
CHS19980HEXiN
Commercial Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 251 gph
27.7 x 34.1 x 64.7
290
199,000
80/ 251
34 x 24 x 63
450
N/A (0.81)
$5,800
RHS19980HEiN
Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph
27.7 x 34.1 x 64.7
290
199,000
80/ 259
34 x 24 x 63
450
N/A (0.81)
$5,800
RHS19980HEiP
Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph
27.7 x 34.1 x 64.7
290
199,000
80/ 259
34 x 24 x 63
450
N/A (0.81)
$5,800
RHS19980HEXiN
Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 251 gph
27.7 x 34.1 x 64.7
290
199,000
80/ 251
34 x 24 x 63
450
N/A (0.81)
$5,800
Commercial Hybrid, Indoor, Max BTU 398,000, First 41.0 x 38.8 x 68.6 Hour Rating: 504 gph
530
398,000
119/504
Rack: 70 x 35 x 66 Tank: 48 x 37.25 x 78
890
97%
$14,200
Commercial Hybrid, Indoor, Max BTU 398,000, First 41.0 x 38.8 x 68.6 Hour Rating: 504 gph
530
398,000
119/504
Rack: 70 x 35 x 66 Tank: 48 x 37.25 x 78
890
97%
$14,200
NEW
CHS398100CUIN NEW
CHS398100CUIP
2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Tankless Rack Systems - Wall Mount (Condensing) The Rinnai Tankless Rack System™ is designed to supply a packaged water heating solution as a fully-assembled system. The TRS includes pre-assembled water and gas connections and manifolds under the tankless water heaters that are properly sized to maintain optimum performance.
TRW23CU
TRW03CU
TRW02CU Rinnai Tankless Wall Rack Systems
Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRW02CUeN
Exterior Wall Hanging Rack, 2 unit NG
44 x 14.1 x 54.8
169
398,000
70 x 35 x 66
390
0.97
N/A
$6,000
TRW02CUeP
Exterior Wall Hanging Rack, 2 unit LPG
44 x 14.1 x 54.8
169
398,000
70 x 35 x 66
390
0.97
N/A
$6,000
TRW02CUiN
Interior Wall Hanging Rack, 2 unit NG
44 x 14.1 x 54.8
170
398,000
70 x 35 x 66
391
0.97
N/A
$6,000
TRW02CUiP
Interior Wall Hanging Rack, 2 unit LPG
44 x 14.1 x 54.8
170
398,000
70 x 35 x 66
391
0.97
N/A
$6,000
TRW23CUeN
2-Unit Exterior Wall Hanging Rack NG
65 x 14.1 x 58
183
398,000
70 x 35 x 66
402
0.97
N/A
$6,000
TRW23CUeP
2-Unit Exterior Wall Hanging Rack LP
65 x 14.1 x 58
183
398,000
70 x 35 x 66
407
0.97
N/A
$6,000
TRW23CUiN
2-Unit Interior Wall Hanging Rack NG
65 x 14.1 x 58
186
398,000
70 x 35 x 66
407
0.97
N/A
$6,000
TRW23CUiP
2-Unit Interior Wall Hanging Rack LP
65 x 14.1 x 58
186
398,000
70 x 35 x 66
407
0.97
N/A
$6,000
TRW03CUeN
Exterior Wall Hanging Rack, 3 unit NG
65 x 14.1 x 54.8
244
597,000
70 x 35 x 66
465
0.97
N/A
$9,000
TRW03CUeP
Exterior Wall Hanging Rack, 3 unit LPG
65 x 14.1 x 54.8
244
597,000
70 x 35 x 66
465
0.97
N/A
$9,000
TRW03CUiN
Interior Wall Hanging Rack, 3 unit NG
65 x 14.1 x 54.8
248
597,000
70 x 35 x 66
469
0.97
N/A
$9,000
TRW03CUiP
Interior Wall Hanging Rack, 3 unit LPG
65 x 14.1 x 54.8
248
597,000
70 x 35 x 66
469
0.97
N/A
$9,000
2018 SUGGESTED LIST PRICE (USD) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Tankless Rack Systems - ST/SE Models (Commercial & Residential) Rinnai SE+ Series Tankless Rack System™ (SE Model) features a sturdy, pre-assembled rack using two super high-efficiency RU199i or RU199e units, providing homeowners with an endless supply of hot water, energy savings, a space saving design and a multitude of environmental benefits. Rinnai SE+ Series Tankless Rack System™ (ST Model) features wall hanging rack that provides redundancy, optimum performance and unparalleled durability. The RUR199i/e or RU199e featuring Rinnai ThermaCirc360™ make recirculation of hot water regardless of the current plumbing configuration. Paired with one or two RUC98i or RUC98e units, the rack will deliver an endless supply of hot water, energy savings, a space saving design and a multitude of environmental benefits.
TRW03ST
TRW02ST
TRW02SE Rinnai ST Series Tankless Wall Rack Systems (Super High-Efficiency with Recirculation) Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRW02STeN
Ext Wall Hanging Rack, 2 unit NG, w/RUR
44 x 14.1 x 58
177
398,000
70 x 35 x 66
398
0.97
0.93
$6,500
TRW02STeP
Ext Wall Hanging Rack, 2 unit LPG, w/RUR
44 x 14.1 x 58
177
398,000
70 x 35 x 66
398
0.97
0.93
$6,500
TRW02STiN
Interior Wall Hanging Rack, 2 unit NG, w
44 x 14.1 x 58
178
398,000
70 x 35 x 66
399
0.97
0.93
$6,500
TRW02STiP
Int Wall Hanging Rack, 2 unit LPG w/RUR
44 x 14.1 x 58
178
398,000
70 x 35 x 66
399
0.97
0.93
$6,500
TRW03STeN
Ext Wall Hanging Rack, 3 unit NG, w/RUR
65 x 14.1 x 58
254
597,000
70 x 35 x 66
472
0.97
0.93
$9,500
TRW03STeP
Ext Wall Hanging Rack, 3 unit LPG, w/RUR
65 x 14.1 x 58
254
597,000
70 x 35 x 66
472
0.97
0.93
$9,500
TRW03STiN
Int Wall Hanging Rack, 3 unit NG, w/RUR
65 x 14.1 x 58
258
597,000
70 x 35 x 66
476
0.97
0.93
$9,500
TRW03STiP
IntWall Hanging Rack, 3 unit LPG, w/RUR
65 x 14.1 x 58
258
597,000
70 x 35 x 66
476
0.97
0.93
$9,500
Rinnai SE Series Tankless Wall Rack Systems (Built with RU199) Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRW02SEeN
Ext Wall Hanging Rack, 2 unit NG, w/RU199
44 x 14.1 x 54.8
169
398,000
70 x 35 x 66
390
0.97
0.93
$5,700
TRW02SEeP
Ext Wall Hanging Rack, 2 unit LPG, w/RU199
44 x 14.1 x 54.8
169
398,000
70 x 35 x 66
390
0.97
0.93
$5,700
TRW02SEiN
Interior Wall Hanging Rack, 2 unit NG, w/ RU199
44 x 14.1 x 54.8
170
398,000
70 x 35 x 66
391
0.97
0.93
$5,700
TRW02SEiP
Int Wall Hanging Rack, 2 unit LPG w/RU199
44 x 14.1 x 54.8
170
398,000
70 x 35 x 66
391
0.97
0.93
$5,700
2018 SUGGESTED LIST PRICE (USD) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Tankless Rack Systems - Corner Rack (Condensing) Rinnai Tankless Rack Systems Corner Rack design solutions are great for food service, hospitality are designed to supply a packaged water heating solution as a fully-assembled system. The TRS includes pre-assembled water and gas connections and manifolds under the tankless water heaters that are properly sized to maintain optimum performance.
TRC02CU
Rinnai Tankless Corner Rack Systems Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRC02CUiN
Corner Rack Assembly Indoor 2 unit NG
32.9 x 32.9 x 45
224
398,000
48 x 50 x 31.5
356
0.97
N/A
$6,190
TRC02CUiP
Corner Rack Assembly Indoor 2 unit LPG
32.9 x 32.9 x 45
224
398,000
48 x 50 x 31.5
356
0.97
N/A
$6,190
2018 SUGGESTED LIST PRICE (USD) • Page 6 Š 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Tankless Rack Systems - HE Models (Non-Condensing) Rinnai HE+ Series Tankless Water Heaters are now available in a pre-assembled wall-hanging rack. Free up premium space with wall mount designs that provide redundancy, optimum performance and unparalleled durability. Using up to three highefficiency RL94i or RL94e is ideal for custom homes with high flow requirements such as multi-head showers and high volume garden or whirlpools tubs. The HE+ Tankless Rack System™ is also an excellent option for fast food or fast casual restaurants or other light commercial applications.
TRW02HE
TRW03HE
Rinnai HE Series Tankless Wall Rack Systems (Built with RU199) Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRW02HEeN
2-Unit Wall Hanging Rack, w/RL94
36.5 x 12.5 x 49.1
120
398,000
70 x 35 x 66
345
N/A
0.81
$5,400
TRW02HEeP
2-Unit Wall Hanging Rack, w/RL94
36.5 x 12.5 x 49.1
120
398,000
70 x 35 x 66
345
N/A
0.81
$5,400
TRW02HEiN
2-Unit Wall Hanging Rack, w/RL94
36.5 x 12.5 x 49.1
120
398,000
70 x 35 x 66
345
N/A
0.81
$5,400
TRW02HEiP
2-Unit Wall Hanging Rack, w/RL94
36.5 x 12.5 x 49.1
120
398,000
70 x 35 x 66
345
N/A
0.81
$5,400
TRW02HEXiN
2-Unit Wall Hanging Rack, w/RL94x
36.5 x 12.5 x 49.1
120
384,000
70 x 35 x 66
345
N/A
0.81
$5,400
TRW03HEeN
3-Unit Wall Hanging Rack, w/RL94
51.5 x 12.5 x 49.1
160
597,000
70 x 35 x 66
385
N/A
0.81
$8,100
TRW03HEeP
3-Unit Wall Hanging Rack, w/RL94
51.5 x 12.5 x 49.1
160
597,000
70 x 35 x 66
385
N/A
0.81
$8,100
TRW03HEiN
3-Unit Wall Hanging Rack, w/RL94
51.5 x 12.5 x 49.1
160
597,000
70 x 35 x 66
385
N/A
0.81
$8,100
TRW03HEiP
3-Unit Wall Hanging Rack, w/RL94
51.5 x 12.5 x 49.1
160
597,000
70 x 35 x 66
385
N/A
0.81
$8,100
TRW03HEXiN
3-Unit Wall Hanging Rack, w/RL94
51.5 x 12.5 x 49.1
160
576,000
70 x 35 x 66
385
N/A
0.81
$8,100
2018 SUGGESTED LIST PRICE (USD) • Page 7 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Tankless Rack Systems- Free-Standing (Condensing) TRS03ILWCU
The Tankless Rack System™ is designed to supply a packaged water heating solun as a fully-assembled system. The TRS includes pre-assembled water and gas connections and manifolds under the tankless water heaters that are properly sized to maintain optimum performance.
TRS02ILWCU
TRS23ILWCU
Rinnai Free-Standing Inline Wall Rack Systems Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRS02ILWCUeN
Exterior Inline Wall Mount Rack, 2 NG
47 x 19.3 x 58
208
398,000
70 x 35 x 66
410
0.97
N/A
$8,180
TRS02ILWCUeP
Exterior Inline Wall Mount Rack, 2 LP
47 x 19.3 x 58
208
398,000
70 x 35 x 66
410
0.97
N/A
$8,180
TRS02ILWCUiN
Interior Inline Wall Mount Rack, 2 NG
47 x 19.3 x 58
208
398,000
70 x 35 x 66
410
0.97
N/A
$8,180
TRS02ILWCUiP
Interior Inline Wall Mount Rack, 2 LP
47 x 19.3 x 58
208
398,000
70 x 35 x 66
410
0.97
N/A
$8,180
TRS23ILWCUeN
2-Unit Exterior Wall Standing Rack NG
65 x 19.3 x 58
222
398,000
70 x 35 x 66
424
0.97
N/A
$8,180
TRS23ILWCUeP
2-Unit Exterior Wall Standing Rack LP
65 x 19.3 x 58
222
398,000
70 x 35 x 66
424
0.97
N/A
$8,180
TRS23ILWCUiN
2-Unit Interior Wall Standing Rack NG
65 x 19.3 x 58
222
398,000
70 x 35 x 66
424
0.97
N/A
$8,180
TRS23ILWCUiP
2-Unit Interior Wall Standing Rack LP
65 x 19.3 x 58
222
398,000
70 x 35 x 66
424
0.97
N/A
$8,180
TRS03ILWCUeN
Exterior Inline Wall Mount Rack, 3 NG
65 x 19.3 x 58
297
597,000
70 x 35 x 66
497
0.97
N/A
$12,565
TRS03ILWCUeP
Exterior Inline Wall Mount Rack, 3 LP
65 x 19.3 x 58
297
597,000
70 x 35 x 66
497
0.97
N/A
$12,565
TRS03ILWCUiN
Interior Inline Wall Mount Rack, 3 NG
65 x 19.3 x 58
297
597,000
70 x 35 x 66
497
0.97
N/A
$12,565
TRS03ILWCUiP
Interior Inline Wall Mount Rack, 3 LP
65 x 19.3 x 58
297
597,000
70 x 35 x 66
497
0.97
N/A
$12,565
2018 SUGGESTED LIST PRICE (USD) • Page 8 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Tankless Rack Systems - Free-Standing (Condensing Cont’d) Rinnai Tankless Free-Standing Rack Systems Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRS02CUeN
Exterior Free Standing Rack, 2 unit NG
47 x 31.1 x 55.6
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS02CUeP
Exterior Free Standing Rack, 2 unit LPG
47 x 31.1 x 55.6
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS02CUiN
Interior Free Standing Rack, 2 unit NG
47 x 31.1 x 55.6
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS02CUiP
Interior Free Standing Rack, 2 unit LPG
47 x 31.1 x 55.6
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS03CUeN
Exterior Free Standing Rack, 3 unit NG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS03CUeP
Exterior Free Standing Rack, 3 unit LPG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS03CUiN
Interior Free Standing Rack, 3 unit NG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS03CUiP
Interior Free Standing Rack, 3 unit LPG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS36CUeN
3-Unit Exterior Free Standing Rack NG
65 x 31.1 x 58
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS36CUeP
3-Unit Exterior Free Standing Rack LP
65 x 31.1 x 58
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS36CUiN
3-Unit Interior Free Standing Rack NG
65 x 31.1 x 58
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS36CUiP
3-Unit Interior Free Standing Rack LP
65 x 31.1 x 58
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS04CUeN
Exterior Free Standing Rack, 4 unit NG
65 x 31.1 x 55.6
365
796,000
70 x 35 x 66
562
0.97
N/A
$15,310
TRS04CUeP
Exterior Free Standing Rack, 4 unit LPG
65 x 31.1 x 55.6
365
796,000
70 x 35 x 66
562
0.97
N/A
$15,310
TRS04CUiN
Interior Free Standing Rack, 4 unit NG
65 x 31.1 x 55.6
365
796,000
70 x 35 x 66
562
0.97
N/A
$15,310
TRS04CUiP
Interior Free Standing Rack, 4 unit LPG
65 x 31.1 x 55.6
365
796,000
70 x 35 x 66
562
0.97
N/A
$15,310
TRS46CUeN
4-Unit Exterior Free Standing Rack NG
65 x 31.1 x 58
386
796,000
70 x 35 x 66
586
0.97
N/A
$15,310
TRS46CUeP
4-Unit Exterior Free Standing Rack LP
65 x 31.1 x 58
386
796,000
70 x 35 x 66
586
0.97
N/A
$15,310
TRS46CUiN
4-Unit Interior Free Standing Rack NG
65 x 31.1 x 58
386
796,000
70 x 35 x 66
586
0.97
N/A
$15,310
TRS46CUiP
4-Unit Interior Free Standing Rack LP
65 x 31.1 x 58
386
796,000
70 x 35 x 66
586
0.97
N/A
$15,310
Model Number
2018 SUGGESTED LIST PRICE (USD) • Page 9 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Tankless Rack Systems- Free-Standing (Condensing Cont’d) Rinnai Tankless Free-Standing Rack Systems Model Number
Product Description
Product Dimensions Inches (W x H x D)
Product Weight (lbs)
Max Heating Input (Btu/h)
Shipping Dimensions Inches (W x H x D)
Shipping Weight (lbs)
Thermal Efficiency
Uniform Energy Factor
List Price (U.S.)
TRS05CUeN
Exterior Free Standing Rack, 5 unit NG
65 x 31.1 x 55.6
462
995,000
70 x 35 x 66
658
0.97
N/A
$19,165
TRS05CUeP
Exterior Free Standing Rack, 5 unit LPG
65 x 31.1 x 55.6
462
995,000
70 x 35 x 66
658
0.97
N/A
$19,165
TRS05CUiN
Interior Free Standing Rack, 5 unit NG
65 x 31.1 x 55.6
462
995,000
70 x 35 x 66
658
0.97
N/A
$19,165
TRS05CUiP
Interior Free Standing Rack, 5 unit LPG
65 x 31.1 x 55.6
462
995,000
70 x 35 x 66
658
0.97
N/A
$19,165
TRS06CUeN
Exterior Free Standing Rack, 6 unit NG
65 x 31.1 x 55.6
538
1,194,000
70 x 35 x 66
731
0.97
N/A
$23,020
TRS06CUeP
Exterior Free Standing Rack, 6 unit LPG
65 x 31.1 x 55.6
538
1,194,000
70 x 35 x 66
731
0.97
N/A
$23,020
TRS06CUiN
Interior Free Standing Rack, 6 unit NG
65 x 31.1 x 55.6
538
1,194,000
70 x 35 x 66
731
0.97
N/A
$23,020
TRS06CUiP
Interior Free Standing Rack, 6 unit LPG
65 x 31.1 x 55.6
538
1,194,000
70 x 35 x 66
731
0.97
N/A
$23,020
Rinnai Tankless Free Standing Inline Rack Systems TRS02ILCUeN
Ext Inline Free Standing Rack, 2unit NG
47 x 31.1 x 55.6
212
398,000
70 x 35 x 66
414
0.97
N/A
$8,180
TRS02ILCUeP
Ext Inline Free Standing Rack, 2unit LPG
47 x 31.1 x 55.6
212
398,000
70 x 35 x 66
414
0.97
N/A
$8,180
TRS02ILCUiN
Int Inline Free Standing Rack, 2unit NG
47 x 31.1 x 55.6
212
398,000
70 x 35 x 66
414
0.97
N/A
$8,180
TRS02ILCUiP
Int Inline Free Standing Rack, 2unit LPG
47 x 31.1 x 55.6
212
398,000
70 x 35 x 66
414
0.97
N/A
$8,180
TRS23ILCUeN
2-Unit Exterior Free Standing Rack NG
65 x 19.3 x 58
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS23ILCUeP
2-Unit Exterior Free Standing Rack LP
65 x 19.3 x 58
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS23ILCUiN
2-Unit Interior Free Standing Rack NG
65 x 19.3 x 58
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS23ILCUiP
2-Unit Interior Free Standing Rack LP
65 x 19.3 x 58
214
398,000
70 x 35 x 66
416
0.97
N/A
$8,180
TRS03ILCUeN
Ext Inline Free Standing Rack, 3unit NG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS03ILCUeP
Ext Inline Free Standing Rack, 3unit LPG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS03ILCUiN
Int Inline Free Standing Rack, 3unit NG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
TRS03ILCUiP
Int Inline Free Standing Rack, 3unit LPG
65 x 31.1 x 55.6
290
597,000
70 x 35 x 66
490
0.97
N/A
$12,565
2018 SUGGESTED LIST PRICE (USD) • Page 10 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Common Vent 3” Common Vent Model Number
Product Description
List Price (U.S.)
790130
3” Kit Direct Vent for Corner Rack and In-line
$170
790131
3” Kit Room air for Corner Rack and In-line
$100
790120
Elbow 3” 45 (2x)
$12
790121
Elbow 3” 90
$9
790122
Extension 3”-39”
$12
790123
Bracket 3” metal
$5
790124
Wall terminal 3” plastic
$20
790125
Roof terminal 3” plastic
$46
Model Number
Product Description
List Price (U.S.)
790132
4” Common vent starter kit DV
$105
790134
4” Common vent in-line 6” DV
$140
790137
4” Common vent starter kit room air
$75
4’’ Common Vent
790142
4’’ Common Vent B2B DV Add on Kits
$240
790143
4’’ Common Vent B2B room air add on kits
$160
790139
4” Common vent in-line room air
$95
790026
Elbow 4” 45 (2x)
$16
790027
Elbow 4” 90
$9
790028
Extension 4”-39”
$14
790088
Extension 4”-78”
$21
790091
Bracket 4” metal
$5
790093
Wall terminal 4” plastic
$44
790095
Roof terminal 4” plastic
$127
790097
Rain cap flue terminal 4”
$28
780060
Rain cap air terminal 4”
$22
790099
4” and 6” flashing 25-45 shingle + Spec. adapter
$42
790101
4” and 6” flat roof flashing
$27
790102
4” extension roof terminal kit plastic
$57
2018 SUGGESTED LIST PRICE (USD) • Page 11 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Common Vent (Cont’d) 6’’ Common Vent Model Number
Product Description
List Price (U.S.)
790133
6” Common vent starter kit DV
$115
790135
6” Common vent in-line 6” DV
$155
790136
6” Common vent B2B 6” DV
$275
790138
6” Common vent starter kit 6” room air
$80
790140
6” Common vent in-line 6” room air
$105
790141
6” Common vent B2B 6” room air
$190
790086
Elbow 6”-45 (2x)
$35
790087
Elbow 6”-87
$18
790089
Extension 6”-39”
$26
790090
Extension 6”-78”
$52
790092
Bracket 6” metal
$5
790094
Wall terminal 6” plastic
$53
790096
Roof terminal 6” plastic
$135
790098
Rain cap flue terminal 6”
$32
780061
Rain cap air terminal 6”
$24
790103
6” extension roof terminal kit metal
$100
790099
4” and 6” flashing 25-45 shingle + Spec. adapter
$42
790101
4” and 6” flashing flat roof
$27
2018 SUGGESTED LIST PRICE (USD) • Page 12 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Commercial Accessories Model Number
Product Description
List Price (U.S.)
107000376
Grundfos UPS 26-99 (S)F Circulation Pump
$530
107000377
Grundfos UPS 26-150 (S)F Circulation Pump
$630
107000378
Grundfos UPS40-160 FB Circulation Pump
$2,400
109000733
TACO 265-3 Digital Timer Controller
$225
109000734
Honeywell L6006C Aquastat Controller
$205
109000735
Honeywell L6006A Aquastat Controller
$225
109000736
1’’ NC Solenoid
$250
109000737
1-1/2’’ NC Solenoid
$650
105000195
Freeze Protection Surge Protector kit KT
$400
MCC-91-2W
Commercial Controller (additional)
$120
REU-EZC-2
EZConnect® Cable for connecting 2 units
$45
REU-CSA-C1
Cascade Harness: 3m
$35
REU-CSA-C2
Cascade Harness: 8m
$65
REU-OPU3
BMS/Air Handler
$45
103000038
ScaleCutter® System 3/4” Feed
$210
103000039
ScaleCutter® System Refill
$110
103000067
Commercial Neutralization Tank w/ Media
$400
103000068
Commercial Neutralization Replacement Media (40 lbs)
$100
PCD07-IB
Pipe Cover (Commercial)
$128
PCD07-IB-BP
Pipe Cover bottom plate (Commercial)
$50
RGB-CTWH-4
Recess Box
$405
RWM101
Control-R™ Wireless Module
$125
RWMPB01
Control-R™ Push Button
$50
RWMMS01
Control-R™ Motion Sensor
$200
RWMKT01
Control-R™ Wireless Demand Recirc w/ Push Button
$175
RWMKT01P
Control-R™ Wireless Demand Recirc w/ Pump and Push Button
$525
RWMKT03
Control-R™ Wireless Demand Recirc w/ Push Button and Temperature Sensor
$400
RWMKT03P
Control-R™ Wireless Demand Recirc w/ Pump, Push Button and Temperature Sensor
$750
ST119
Gray 119 Gallon Storage Tank
$2,400
2018 SUGGESTED LIST PRICE (USD) • Page 13 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type
Internal (Indoor) Commercial Applications
Model Numbers
CU199i (REU-N3237FFC-US) CU160i (REU-N2530FFC-US)
Approved Gas Types
Natural and Propane
Thermal Efficiency
Up to 97%
Uniform Energy Factor (UEF)
0.93
Energy Factor (EF) (Canada)
CU199i: CU160i:
High Altitude Approved
Up to 10,200 ft (3,109 m) Water Flow Sensor, Electronic Water Control and Bypass Control Standard: Integrated Controller Optional: MC-91-2US
Water Flow Control Controller Certifications
Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Vent lengths up to 150 ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths:
Vent Lengths
2 in. (51 mm)
3 in. (76 mm)
65 ft (20 m)
150 ft (46 m)
Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2), and Self-Tapping Screws (x2) Additional Features • Complies with South Coast • Ultra Low NOx Air Quality Management District 14 ng/J or 20 ppm • Tankless Rack System™ Compatible • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels
Concentric
• • • •
Vent Sizes
2 in. X 4 in.
3 in. X 5 in.
Vent Lengths
65 ft (20 m)
150 ft (46 m)
AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
Warranty • Heat Exchanger: 8 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year
• • • •
Twin Pipe Vent Sizes
0.96 0.95
Commercial Tankless Rack Systems
Compact Design to Save Space Wi-Fi Technology for Remote Monitoring and Management Sliding Mounting Bracket for Easy Installation Simple Gas Conversion
Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Cascade Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
●
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Demand Duo™ Commercial Hybrid System
in. (mm)
Electrical
SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level
CU199i CU160i 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm)
FRONT
15,000 199,000
160,000
0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 64 lb (29 kg) 49 dB
0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 62 lb (28 kg) 48 dB
Normal Standby
84 W
52 W 1.3 W
Freeze Protection Max Current
148 W 4 Amps
Fuse
10 Amps
• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default
Temperature
185° F (85° C) With Parameter Adjustment
SIDE
By-Pass Flow Control
Electronic
Gas Supply Pressure2
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Vent Connection:
Ignition System
Direct Electronic Ignition
2 in. (51 mm)
• • • •
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)
nominal PVC/
• • • • • • •
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT
Electronic Connections
Polypropylene or
Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)
Water Supply Pressure Controller Cable Service Connections
Clearances
Top: 2 in. (51 mm)* Bottom/Ground: 12 in. (305 mm) Front: 0 in.**
3 in./5 in. Concentric.
• Back: 0 in. • Sides: 2 in. (51 mm)*** • Vent: 0 in.
* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box
BOTTOM
1
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
Connection COLD HOT GAS 0
25
50
75
100
125
150
PRV
F C H B E D G A
in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER
• • • •
Installation Type
External (Outdoor) Commercial Applications
Model Numbers
CU199e (REU-N3237WC-US) CU160e (REU-N2530WC-US)
Approved Gas Types
Natural and Propane
Thermal Efficiency
Up to 97%
Uniform Energy Factor (UEF)
0.93
Energy Factor (EF) (Canada)
0.96
High Altitude Approved
Up to 10,200 ft (3,109 m)
Water Flow Control
Water Flow Sensor, Electronic Water Control and Bypass Control
Controller
Standard: Integrated Controller Optional: MC-91-2US
Certifications
AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
Warranty
Compact Design to Save Space
• Heat Exchanger: 8 years or 12,000 operation hours, whichever
Wi-Fi Technology for Remote Monitoring and Management
occurs first
Simple Gas Conversion
• All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year
Electronically Connect up to 24 Water Heaters to Operate as One Hot Water Source
Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection
Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
Included with Purchase
• • • • •
Commercial Tankless Rack Systems
Tankless Water Heater Pressure Relief Valve and Adapter Isolation Valve Kit Integrated Controller Recirculation Pump Cable
Additional Features
• Fully-assembled, comprehensive water heating solutions
• Numerous configurations: Free
• Complies with South Coast • Ultra Low NOx Air Quality Management • Tankless Rack System™ Compatible District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels
Standing, Inline Free Standing, Inline Wall Mount, Wall Hanging, and Corner
• Made to Order Customized Solutions
● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
in. (mm)
Electrical
SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level
FRONT
CU199e CU160e 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000
Normal Standby
199,000
160,000
0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 64 lb (29 kg) 53 dB
0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 62 lb (28 kg) 52 dB
81 W
49 W 1.3 W
Freeze Protection Max Current
152 W 4 Amps
Fuse
10 Amps
Temperature
• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default
By-Pass Flow Control
Electronic
Gas Supply Pressure2
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
185° F (85° C) With Parameter Adjustment SIDE
• • • •
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)
Service Connections
• • • •
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT
Clearances
• Top: 2 in. (51 mm)* • Back: 0 in. • Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** • Front: 0 in.** • Front Exhaust: 24 in. (610 mm)
Electronic Connections Water Supply Pressure Controller Cable
Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)
* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box
BOTTOM
1
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
Connection COLD HOT GAS 0
25
50
75
100
125
150
PRV
F C H B E D G A
in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193
Demand Duo™ 80 Hybrid Water Heating System Direct Vent Options
• Concentric: Ubbink Concentric Non-Condensing Vent Clearances from Combustibles (RL94iRLX94i)
• Top of heater - 6 in. (152mm)* • Front of heater - 6 in. (152mm)** • Sides of heater - 2 in. (51mm)
• Back of heater - 0 in. • Bottom of heater - 12 in. (305mm) • From vent pipe - 0 in.
Clearances from Non-Combustibles (RL94i/RLX94i)
• Top of heater - 2 in. (51mm)* • Front of heater - 6 in. (152mm)** • Sides of heater - 1/2 in. (13mm)
• Back of heater - 0 in. • Bottom of heater - 12 in. (305mm) • From vent pipe - 0 in.
*54 in. (1371.6mm) required for anode rod serviceability **24 in. (610mm) required for serviceability Safety Features
• • • •
• Remaining flame (OHS) • Thermal fuse • Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Storage Tank
• Pre-installed temperature & pressure relief valve • 2 in. Foam insulation • Brass drain valve • Glass-lined inner tank • 1.5 in. MNPT dielectric hot and cold • Dual magnesium anode rods connections • Hand hole clean-out Limited Warranty
• • • •
Maximum Gas Consumption: 199,000 BTU/h Temperature Range F (C):
• •
Commercial: 98°- 185° (37°- 85°)
• •
RL94i: 259 Gallons (980 L)
Heat Exchanger: Residential - 12 years* / Commercial - 5 years* Tank: 6 years* All Other Parts: 5 years*
Labor: 1 year* (*Reference Tankless Water Heater manual for further warranty information.)
Residential: 98°- 140° (37°- 60°) Tank Capacity: 80 Gallons (303 L) First Hour Delivery (100°F Rise): RLX94i: 251 Gallons (950L)
Front
DIMENSIONS
Side
HOT OUTLET
Top 1-1/2” MNPT (HOT)
27.74 Ø 24.25 12.13 HOT
56.83
28.64 30.00°
Dual Anodes
62.69
54.28 T&P
64.71
29.29 (GAS)
24.53 PRV
4.19 COLD
1-1/2” MNPT (COLD)
3.54 DRAIN
WEIGHT: 290 lb (132 kg) © 2017 Rinnai America Corporation
28.66 (GAS) 34.05
COLD INLET
Demand Duo 80-SP
11/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Demand Duo™ 80 Hybrid Water Heating System Product Number
CHS19980HEiP
Product Description
CHS19980HEXiN
Hybrid System: Non-condensing tankless, Insulated Storage Tank, Pump & Control 10,300 (3.0) 199,000 (58.3) 192,000 (56.3) 80 Gallons (303 Liters) 0.81 259 Gallons 251 Gallons (980 Liters) (950 Liters) 98° F (37° C) to 185° F (85° C) 290 lb (132 kg) 49 dB 278 W 44 W
Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h) Tank Volume Uniform Energy Factor (RL94i) First Hour Delivery Temperature Setting Product Weight Noise level
System Electrical Data
CHS19980HEiN
Normal Standby Anti-frost Protection Max Current Fuse
300 W 5.5 A Tankless Engine - 10 A, System Controller - 10 A Electronic 8.0 - 13.5 inch W.C. 4.0 - 10.5 inch W.C. 4.0 - 10.5 inch W.C.
By-Pass Control Gas Supply Pressure
Gas Supply Inlet - 3/4 in. MNPT Hot Water Outlet - 1-1/2 in. MNPT Cold Water Inlet - 1-1/2 in. MNPT
Connections Ignition System
Direct Electronic Ignition Appliance: AC 120 Volts, 60Hz. Integrated Temperature Controller: DC 12 Volts (Digital)
Electric Connections Water Temperature Control
Simulation Feed forward and Feedback
Maximum Water Supply Pressure
150 PSI
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels (RL94i)
Yes
No
Yes
RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED Tank Capacity
CHS19980HE
CHS19980HEX
°F
30°F 40°F
50°F
60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F
°C
17°C 22°C
28°C
33°C 39°C 44°C 50°C
56°C
61°C
67°C
72°C
78°C
507
405
338
253
225
203
184
169
156
145
303 Liters LPH 2557 1917
1534
1278 1096 959
852
767
697
639
590
548
489
391
326
244
217
195
178
163
150
140
303 Liters LPH 2467 1850
1480
1233 1057 925
822
740
673
617
569
529
80 U.S. Gals.
80 U.S. Gals.
GPH 675
GPH 652
289
279
RL94 Tankless Water Heater maintains the following certifications:
© 2017 Rinnai America Corporation
Demand Duo 80-SP-1
C
US
Low Lead Content NSF/ANSI 372
11/2017
SANITATION
Demand Duo™ 80 Hybrid Water Heating System Product Number
RHS19980HEiP
Product Description Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h) Tank Volume Uniform Energy Factor (RL94i) First Hour Delivery Temperature Setting Product Weight Noise level
System Electrical Data
Normal Standby Anti-frost Protection Max Current Fuse
By-Pass Control Gas Supply Pressure
RHS19980HEiN
RHS19980HEXiN
Hybrid System: Non-condensing tankless, Insulated Storage Tank, Pump & Control 10,300 (3.0) 199,000 (58.3) 192,000 (56.3) 80 Gallons (303 Liters) 0.81 259 Gallons 251 Gallons (980 Liters) (950 Liters) 98° F (37° C) to 140° F (60° C) 290 lb (132 kg) 49 dB 278 W 44 W 300 W 5.5 A Tankless Engine - 10 A, System Controller - 10 A Electronic 8.0 - 13.5 inch W.C. 4.0 - 10.5 inch W.C. 4.0 - 10.5 inch W.C. Gas Supply Inlet - 3/4 in. MNPT Hot Water Outlet - 1-1/2 in. MNPT Cold Water Inlet - 1-1/2 in. MNPT
Connections Ignition System
Direct Electronic Ignition Appliance: AC 120 Volts, 60Hz. Integrated Temperature Controller: DC 12 Volts (Digital)
Electric Connections Water Temperature Control
Simulation Feed forward and Feedback
Maximum Water Supply Pressure
150 PSI
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels (RL94i)
Yes
No
Yes
RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED Tank Capacity
CHS19980HE
CHS19980HEX
80 U.S. Gals.
°F
30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F
°C
17°C 22°C 28°C 33°C 39°C 44°C 50°C
56°C
61°C
67°C
72°C
78°C
675
289
253
225
203
184
169
156
145
303 Liters LPH 2557 1917 1534 1278 1096
959
852
767
697
639
590
548
279
244
217
195
178
163
150
140
303 Liters LPH 2467 1850 1480 1233 1057
925
822
740
673
617
569
529
80 U.S. Gals.
GPH
GPH
652
507
489
405
391
338
326
RL94 Tankless Water Heater maintains the following certifications:
© 2017 Rinnai America Corporation
Demand Duo 80-SP-1
C
US
Low Lead Content NSF/ANSI 372
SANITATION
11/2017
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
SUPER-HIGH-EFFICIENCY (CONDENSING) HYBRID WATER HEATING SYSTEM
Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Vent lengths up to 150 ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths:
Vent Lengths
2 in. (51 mm)
3 in. (76 mm)
65 ft (20 m)
150 ft (46 m)
2 in. X 4 in.
3 in. X 5 in.
Vent Lengths
65 ft (20 m)
150 ft (46 m)
Model Numbers
RHS199100SE
Approved Gas Types
Natural and Propane
Maximum Gas Consumption
199,000 Btu/h (58.3 kW/h)
Uniform Energy Factor (UEF)
RU199i: 0.93
Energy Factor (EF) (For Canada)
RU199i: 0.96
First Hour Delivery (100°F Rise)
315 Gallons (1,192 L)
High Altitude Approved
Up to 10,200 Ft (3,109 M)
Tank Capacity
119 Gallons (450 L)
Water Flow Control
Water Flow Sensor, Electronic Water Control and Bypass Control
Controller
Standard: Integrated Controller Optional: MC-91-2US
Certifications
AHRI, ANSI Z21.10.3, CSA 4.3, and Energy Star®
Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • Tank: 6 years • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year (Refer to the Installation and Operation Manual for further warranty information.) Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection
Concentric Vent Sizes
Internal (Indoor) Residential Applications
Storage Tank • 2 in. (51 mm) Eco-friendly foam insulation • Glass-lined inner tank • 1-1/2 in. (38 mm) MNPT dielectric hot and cold connections • Pre-installed temperature and pressure relief valve • Brass drain valve • Dual magnesium anode rods • Hand hole clean-out
• • • •
Twin Pipe Vent Sizes
Installation Type
Additional Features • Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels
Condensate Neutralizer, ScaleCutter, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
• Ultra Low NOx • 1/2 in. (13 mm) Gas Line Compatible
• Wi-Fi Technology for Remote Monitoring and Management (with Control-R™ Wi-Fi Module accessory)
• Simple Gas Conversion
●
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
INCHES SPECIFICATION
Condensing Hybrid System: Condensing Tankless Water Heater, Insulated Storage Tank, Pump and Control
Product Description Minimum Gas Consumption Btu/h (kW/h)
15,000 (4.5)
Maximum Gas Consumption Btu/h (kW/h)
199,000 (58.3)
Tank Volume
119 Gallons (450 Liters)
Weight
431 lb (195 kg)
Sound Level
Electrical
TOP
RHS199100SE
49 dB
Normal
265 W
Standby
44 W
Freeze Protection
148 W
Max Current
FRONT
5.5 Amps
Fuse
Tankless Engine: 10 Amps, System Controller 10 Amps
• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default
Temperature
185° F (85° C) With Parameter Adjustment
By-Pass Flow Control
Electronic
Gas Supply Pressure
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
Electronic Connections
• Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital)
Water Supply Pressure
• Maximum: 150 PSI
Service Connections
• • • •
Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 1-1/2 in. (38 mm) NPT Hot Water Outlet: 1-1/2 in. (38 mm) NPT Condensate Drain: 1/2 in. (13 mm) (SOCKET)
T&P - Temperature and Pressure relief valve
RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED
Tank Capacity
°F
30°F
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
°C
17°C
22°C
28°C
33°C
39°C
44°C
50°C
56°C
61°C
67°C
72°C
78°C
119 U.S. Gals.
GPH
772
579
463
386
331
289
257
232
211
193
178
165
450 Liters
LPH
2922
2192
1753
1461
1253
1093
973
878
799
731
673
625
Demand Duo™ Commercial Hybrid Water Heating System Direct Vent Options
Concentric: Ubbink Polypropylene Concentric Vent Twin Pipe: PVC / CPVC (3” and 4” Configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adaptor)
Common Vent Solutions Room Air: PVC or PP 3” or 4 “ (VERTICAL TERMINATIONS ONLY) -Flue check valve for room air included with system. Clearances from Combustibles (C199i)
Top of heater - 6 in (152mm)* Front of heater - 6 in (152mm)** Sides of heater - 2 in (51mm)
Back of heater - 0 in Bottom of heater - 12 in (305mm) From vent pipe - 0 in
Clearances from Non-Combustibles (C199i)
Top of heater - 2 in (51mm)* Front of heater - 6 in (152mm)** Sides of heater - 1/2 in (13mm)
Back of heater - 0 in Bottom of heater - 12 in (305mm) From vent pipe - 0 in
*54 in (1371.6mm) required for anode rod serviceability **24 in (610mm) required for serviceability Safety Features
Remaining flame (OHS) Thermal fuse Automatic frost protection
Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse
Storage Tank
2” Eco-friendly foam insulation Glass-lined inner tank 2” MNPT dielectric hot and cold
Maximum Gas Consumption: 199,000 BTU/h
connections
Pre-installed temperature & pressure relief valve Brass drain valve Dual magnesium anode rods Hand hole clean-out
Commercial Limited Warranty
Thermal Efficiency: 96% (C199i) Temperature Range F (C): 98°- 185° (37°- 85°) Tank Capacity: 119 Gallons (450 L) First Hour Delivery (100°F Rise): 315 Gallons (1192 L)
DIMENSIONS
Front
Heat Exchanger: 6 years* Tank: 6 years* All Other Parts: 5 years*
Labor: 1 year* (*Reference Tankless Water Heater manual for further warranty information.) HOT OUTLET
Side
Top
Dual Anodes
WEIGHT: 428 lb (194 kg) COLD INLET
© 2015 Rinnai Corporation
CHS199100-SP
10/2015
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Demand Duo™ Commercial Hybrid Water Heating System Product Number
CHS199100 Condensing Hybrid System: Condensing tankless, Insulated Storage Tank, Pump & Control
Product Description Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h)
15,200 (4.5) 199,000 (58.3) 119 Gallons (450 Liters) 96% 315 Gallons (1192 Liters) 98° F (37° C) to 185° F (85° C) 428 lb (194 kg) 52 dB 256 W 44 W 326 W 5.5 A Tankless Engine - 10 A, System Controller - 10 A
Tank Volume Thermal Efficiency (C199i) First Hour Delivery Temperature Setting Product Weight Noise level Normal Standby Anti-frost Protection Max Current Fuse
System Electrical Data
By-Pass Control
Electronic Natural Gas Propane
Gas Supply Pressure
4.0 - 10.5 inch W.C. 8.0 - 13.5 inch W.C. Gas Supply Inlet - 3/4" MNPT Hot Water Outlet - 2" MNPT Cold Water Inlet - 2" MNPT
Connections Ignition System
Direct Electronic Ignition Appliance: AC 120 Volts, 60Hz. Integrated Temperature Controller: DC 12 Volts (Digital)
Electric Connections Water Temperature Control
Simulation Feed forward and Feedback
Maximum Water Supply Pressure
150 PSI Yes
Commercial Energy Star Certified (C199i) Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels (C199i)
Yes
RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED
Tank Capacity
°F
30°F
40°F
°C
17°C 22°C 28°C 579
50°F 463
60°F 70°F 80°F 90°F
100°F
33°C 39°C 44°C 50°C 56°C 386
331
110°F 120°F 130°F 140°F 61°C
67°C
72°C
78°C
119 U.S. Gals.
GPH
772
289
257
232
211
193
178
165
450 Liters
LPH
2922 2192 1753 1461 1253 1093
973
878
799
731
673
625
C199i Tankless Water Heater maintains the following certifications: C
US
Low Lead Content NSF/ANSI 372
SANITATION
SUPER-HIGH-EFFICIENCY (CONDENSING) HYBRID WATER HEATING SYSTEM Installation Type
Internal (Indoor) Commercial Applications
Model Numbers
CHS199100CU
Approved Gas Types
Natural and Propane
Maximum Gas Consumption
199,000 BTU/h
Thermal Efficiency
Up to 97%
First Hour Delivery (100°F Rise)
315 Gallons (1192 L)
High Altitude Approved
Up to 10,200 Ft (3,109 M)
Tank Capacity
119 Gallons (450 L)
Water Flow Control
Water Flow Sensor, Electronic Water Control and Bypass Control
Controller
Standard: Integrated Controller Optional: MC-91-2US
Certifications
AHRI, ANSI Z21.10.3, CSA 4.3, and Energy Star®
Storage Tank • 2” Eco-friendly foam insulation • Glass-lined inner tank • 1-1/2” MNPT dielectric hot and cold connections • Pre-installed temperature & Pressure relief valve • Brass drain valve • Dual magnesium anode rods • Hand hole clean-out
• • • •
Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Vent lengths up to 150 Ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes Vent Lengths
2 in. (51 mm)
3 in. (76 mm)
65 ft (20 m)
150 ft (46 m)
Warranty • Heat Exchanger: 8 years or 12,000 operation hours, whichever occurs first • Tank: 6 years • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year (Refer to the Installation and Operation Manual for further warranty information.) Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Additional Features • Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels
Concentric Vent Sizes
2 in. X 4 in.
3 in. X 5 in.
Vent Lengths
65 ft (20 m)
150 ft (46 m)
• Ultra Low NOx • Tankless Rack System™ Compatible • 1/2 in. (13 mm) Gas Line Compatible
Room Air Screen, Condensate Neutralizer, ScaleCutter, ControlR™ WI-FI Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.
• Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion
●
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
INCHES SPECIFICATION
CHS199100CU Condensing Hybrid System: Condensing Tankless, Insulated Storage Tank, Pump & Control
Product Description Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h)
15,000 (4.5) 199,000 (58.3) 119 Gallons (450 Liters) Up to 97% 431 lb (195 kg) 49 dB
Tank Volume Thermal Efficiency (CU199i) Weight Sound Level
Electrical
TOP
Normal Standby
265 W 44 W
Freeze Protection Max Current
148 W 5.5 Amps
Fuse
Tankless Engine: 10 Amps, System Controller 10 Amps
• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default
Temperature
185° F (85° C) With Parameter Adjustment
By-Pass Flow Control
Electronic
Gas Supply Pressure
• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System
Direct Electronic Ignition
2
Electronic Connections Water Supply Pressure Service Connections
FRONT
• • • • • • •
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital) Maximum: 150 PSI Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 1-1/2 in. ( mm) NPT Hot Water Outlet: 1-1/2 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) (SOCKET)
RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED
Tank Capacity
°F
30°F
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
°C
17°C
22°C
28°C
33°C
39°C
44°C
50°C
56°C
61°C
67°C
72°C
78°C
119 U.S. Gals.
GPH
772
579
463
386
331
289
257
232
211
193
178
165
450 Liters
LPH
2922
2192
1753
1461
1253
1093
973
878
799
731
673
625
rinnai.us
1-800-621-9419
SPECIFICATIONS
Tankless Rack System
Free-Standing Rack with Six Rinnai Tankless Water Heaters
For complete details on commercial water heating solutions and maintenance services call 866-383-0707 or email commercialservices@rinnai.us. Rinnai Tankless Rack System Specification Sheet JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
1
Configurations TRS configurations and part numbers are listed in the following tables.
WALL-HANGING RACKS CU Series Part No.* TRW02CUiN
Rack type
Configuration
Illustration
Configuration
Illustration
2-unit interior wall-hanging rack, NG
TRW02CUeN 2-unit exterior wall-hanging rack, NG TRW02CUiP
2-unit interior wall-hanging rack, LP
TRW02CUeP 2-unit exterior wall-hanging rack, LP TRW23CUiN
2-unit interior wall-hanging rack, NG
TRW23CUeN 2-unit exterior wall-hanging rack, NG TRW23CUiP
2-unit interior wall-hanging rack, LP
TRW23CUeP 2-unit exterior wall-hanging rack, LP TRW03CUiN
3-unit interior wall-hanging rack, NG
TRW03CUeN 3-unit exterior wall-hanging rack, NG TRW03CUiP
3-unit interior wall-hanging rack, LP
TRW03CUeP 3-unit exterior wall-hanging rack, LP
SE Series Part No.*
Rack type
TRW02SEiN
2-unit interior wall-hanging rack, NG RUC
TRW02SEeN
2-unit exterior wall-hanging rack, NG RUC
TRW02SEiP
2-unit interior wall-hanging rack, LP RUC
TRW02SEeP
2-unit exterior wall-hanging rack, LP RUC
SE+ Series Featuring ThermaCirc360â„¢ Part No.*
Rack type
TRW02STiN
2-unit interior wall-hanging rack, NG
TRW02STeN
2-unit exterior wall-hanging rack, NG
TRW02STiP
2-unit interior wall-hanging rack, LP
TRW02STeP
2-unit exterior wall-hanging rack, LP
TRW03STiN
3-unit interior wall-hanging rack, NG
TRW03STeN
3-unit exterior wall-hanging rack, NG
TRW03STiP
3-unit interior wall-hanging rack, LP
TRW03STeP
3-unit exterior wall-hanging rack, LP
Configuration
Illustration
* Part No. Legend: TR = Tankless Rack; W = Wall Hanging; S = Stand Alone; IL = Inline; ILW = Inline Wall Mount; 2/3/4/5/6 = Number of Water Heaters; i/e = Interior/Exterior; NG/LP = Natural Gas/Liquid Propane 2
Rinnai Tankless Rack System Specification Sheet
Wall Hanging Configurations (Continued)
HE+ Series Part No.*
Rack type
TRW02HEiN
2-unit interior wall-hanging rack, NG [1]
TRW02HEXiN
2-unit interior wall-hanging rack, NG [2]
TRW02HEeN
2-unit exterior wall-hanging rack, NG
TRW02HEiP
2-unit interior wall-hanging rack, LP
TRW02HEeP
2-unit exterior wall-hanging rack, LP
TRW03HEiN
3-unit interior wall-hanging rack, NG [1]
TRW03HEXiN
3-unit interior wall-hanging rack, NG [2]
TRW03HEeN
3-unit exterior wall-hanging rack, NG
TRW03HEiP
3-unit interior wall-hanging rack, LP
TRW03HEeP
3-unit exterior wall-hanging rack, LP
[1] [2]
Configuration
Illustration
For use with Rinnai RL94i Tankless Water Heaters. For use with Rinnai RLX94i Tankless Water Heaters.
WALL-MOUNT RACKS Part No.*
Rack type
TRS02ILWCUiN
Configuration
Illustration
2-unit interior wall-mount rack, NG
TRS02ILWCUeN 2-unit exterior wall-mount rack, NG TRS02ILWCUiP
2-unit interior wall-mount rack, LP
TRS02ILWCUeP 2-unit exterior wall-mount rack, LP TRS23ILWCUiN
2-unit interior wall-mount ount rack, NG
TRS23ILWCUeN 2-unit exterior wall-mount mount rack, NG TRS23ILWCUiP
2-unit interior wall-mount rack, LP
TRS23ILWCUeP 2-unit exterior wall-mount rack, LP TRS03ILWCUiN
3-unit interior wall-mount rack, NG
TRS03ILWCUeN 3-unit exterior wall-mount rack, NG TRS03ILWCUiP
3-unit interior wall-mount rack, LP
TRS03ILWCUeP 3-unit exterior wall-mount rack, LP
CORNER-HANGING RACKS Part No.*
Rack type
TRC02CUiN
2-unit interior corner-hanging rack, NG
TRC02CUiP
2-unit interior corner-hanging rack, LP
Configuration
Illustration
* Part No. Legend: TR = Tankless Rack; W = Wall Hanging; S = Stand Alone; IL = Inline; ILW = Inline Wall Mount; 2/3/4/5/6 = Number of Water Heaters; i/e = Interior/Exterior; NG/LP = Natural Gas/Liquid Propane Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
3
FREE-STANDING RACKS Part No.*
Rack type
Configuration
TRS02CUiN
2-unit interior free-standing rack, NG
TRS02CUeN
2-unit exterior free-standing rack, NG
TRS02CUiP
2-unit interior free-standing rack, LP
TRS02CUeP
2-unit exterior free-standing rack, LP
TRS02ILCUiN
2-unit INLINE interior free-standing rack, NG
TRS02ILCUeN
2-unit INLINE exterior free-standing rack, NG
TRS02ILCUiP
2-unit INLINE interior free-standing rack, LP
TRS02ILCUeP
2-unit INLINE exterior free-standing rack, LP
TRS23ILCUiN
2-unit INLINE interior free-standing rack, NG
TRS23ILCUeN
2-unit INLINE exterior free-standing rack, NG
TRS23ILCUiP
2-unit INLINE interior free-standing rack, LP
TRS23ILCUeP
2-unit INLINE exterior free-standing rack, LP
TRS03ILCUiN
3-unit INLINE interior free-standing rack, NG
TRS03ILCUeN
3-unit INLINE exterior free-standing rack, NG
TRS03ILCUiP
3-unit INLINE interior free-standing rack, LP
TRS03ILCUeP
3-unit INLINE exterior free-standing rack, LP
TRS03CUiN
3-unit interior free-standing rack, NG
TRS03CUeN
3-unit exterior free-standing rack, NG
TRS03CUiP
3-unit interior free-standing rack, LP
TRS03CUeP
3-unit exterior free-standing rack, LP
TRS36CUiN
3-unit interior free-standing rack, NG
TRS36CUeN
3-unit exterior free-standing rack, NG
TRS36CUiP
3-unit interior free-standing rack, LP
TRS36CUeP
3-unit exterior free-standing rack, LP
TRS04CUiN
4-unit interior free-standing rack, NG
TRS04CUeN
4-unit exterior free-standing rack, NG
TRS04CUiP
4-unit interior free-standing rack, LP
TRS04CUeP
4-unit exterior free-standing rack, LP
TRS46CUiN
4-unit interior free-standing rack, NG
TRS46CUeN
4-unit exterior free-standing rack, NG
TRS46CUiP
4-unit interior free-standing rack, LP
TRS46CUeP
4-unit exterior free-standing rack, LP
TRS05CUiN
5-unit interior free-standing rack, NG
TRS05CUeN
5-unit exterior free-standing rack, NG
TRS05CUiP
5-unit interior free-standing rack, LP
TRS05CUeP
5-unit exterior free-standing rack, LP
TRS06CUiN
6-unit interior free-standing rack, NG
TRS06CUeN
6-unit exterior free-standing rack, NG
TRS06CUiP
6-unit interior free-standing rack, LP
TRS06CUeP
6-unit exterior free-standing rack, LP
Illustration
Back to Back
* Part No. Legend: TR = Tankless Rack; W = Wall Hanging; S = Stand Alone; IL = Inline; ILW = Inline Wall Mount; 2/3/4/5/6 = Number of Water Heaters; i/e = Interior/Exterior; NG/LP = Natural Gas/Liquid Propane
4
Rinnai Tankless Rack System Specification Sheet
Specifications WALL-HANGING RACKS Available Configurations • 2-Units • 3-Units
CU Series
2-Unit Wa l l - H a n g i n g F r a m e LEFT
FRONT
BACK
7.58
BOTTOM Model
Configuration
Illustration
TRW02CU
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
5
CU Series 2-Unit Wall-Hanging Frame (Continued) Model Water Heater Model
TRW02CUi CU199i (NG/LP)
TRWCU02CUe CU199e (NG/LP)
Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs Rack Frame - Specifications Frame Material Frame Finish Color
66 x 70 x 35 170 380
169 379
14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray
16 Gauge Stainless Steel 1.5” Square Tube Stainless Stainless
Water & Gas Connections Hot Water Trunk Line Diameter
2"
Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type
2" Rigid Copper Rigid Copper 2" Pipe 1-1/4" 1-1/4” MNPT
Gas Trunk Line Material Gas Branch Line Material Electric Requirements Voltage
Sch 40 Steel PVC Over CSST AC 120 Volts—60 Hz
Maximum Current (Amperes)
8 BTU and Flow Rates for C199i, CU199e (NG/LP)
Number of Tankless Water Heaters
2
Flow rate @ 70°F rise (gpm)
10.8
Flow rate @ 100°F rise (gpm)
7.6
Minimum input rate (Btuh) Maximum input rate (Btuh)
15,200 398,000
TRW02CU
6
Rinnai Tankless Rack System Specification Sheet
WALL-HANGING RACKS → CU SERIES
CU Series
3-Unit Wa l l - H a n g i n g F r a m e
FRONT
LEFT
BACK
BOTTOM
Model
Configuration
Illustration
TRW03CU
TRW23CU
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
7
CU Series 3-Unit Wall-Hanging Frame (Continued) Model
TRW03CUi
Water Heater Model
TRW03CUe
TRW23CUi
CU199i (NG/LP) CU199e (NG/LP) 66 x 70 x 35 248 244 469 465
Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs
TRW23CUe
CU199i (NG/LP) CU199e (NG/LP) 66 x 70 x 35 186 183 407 402
Rack Frame - Specifications 14 Gauge Hot Rolled 16 Gauge Steel 1.5” Square Stainless Steel Tube 1.5” Square Tube
Frame Material Frame Finish Color
14 Gauge Hot Rolled Steel 1.5” Square Tube
16 Gauge Stainless Steel 1.5” Square Tube
Powder Coat
Stainless
Powder Coat
Stainless
Gray
Stainless
Gray
Stainless
Water & Gas Connections Hot Water Trunk Line Diameter
2"
Cold Water Trunk Line Diameter
2"
Hot Water Trunk Line Material
Rigid Copper
Cold Water Trunk Line Material
Rigid Copper
Water Trunk Connection Type
2" PIPE
Gas Trunk Line Diameter
1-1/4"
Gas Trunk Connection Type
1-1/4” MNPT
Gas Trunk Line Material
Sch 40 Steel
Gas Branch Line Material
PVC Over CSST
Electric Requirements Voltage
AC 120 Volts—60 Hz
Maximum Current (Amperes)
12
8
BTU and Flow Rates for CU199i, CU199e (NG/LP) Number of Tankless Water Heaters
3
2
Flow rate @ 70°F rise (gpm)
16.2
10.8
Flow rate @ 100°F rise (gpm)
11.4
7.6
Minimum input rate (Btuh)
15,200
15,200
Maximum input rate (Btuh)
597,000
398,000
TRW03CU
8
TRW23CU
Rinnai Tankless Rack System Specification Sheet
WALL-HANGING RACKS → SE SERIES
SE Series
2-Unit Wa l l - H a n g i n g F r a m e
LEFT
FRONT
BACK
36.00
BOTTOM Model
Configuration
Illustration
TRW02SE
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
9
SE Series 2-Unit Wall-Hanging Frame (Continued) Model Water Heater Model
TRW02SEi RU199i (NG/LP)
TRW02SEe RU199e (NG/LP)
Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs
66 X 70 X 35 170 391
169 390
14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray
16 Gauge Stainless Steel 1.5” Square Tube Stainless Stainless
Rack Frame - Specifications Frame Material Frame Finish Color Water & Gas Connections Hot Water Trunk Line Diameter
2"
Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type
2" Rigid Copper Rigid Copper 2" PIPE 1-1/4" 1-1/4” MNPT
Gas Trunk Line Material Gas Branch Line Material Electric Requirements Voltage
Sch 40 Steel PVC Over CSST AC 120 Volts—60 Hz
Maximum Current (Amperes)
8 BTU and Flow Rates for RU199i, RU199e (NG/LP)
Number of Tankless Water Heaters
2
Flow rate @ 70°F rise (gpm)
10.8
Flow rate @ 100°F rise (gpm)
7.6
Minimum input rate (Btuh) Maximum input rate (Btuh)
15,200 398,000
TRW02SE
10
Rinnai Tankless Rack System Specification Sheet
WALL-HANGING RACKS → SE+ SERIES FEATURING THERMACIRC360™
SE+ Series Featuring ThermaCirc360™
LEFT
2-Unit Wa l l - H a n g i n g F r a m e
FRONT
BACK
14.38 HOT (2”COPPER) 9.38 COLD (2”COPPER)
14.50 HOT (2”COPPER) 4.50 GAS(1-1/4”NPT)
9.50 COLD (2”COPPER) 4.63 GAS (1-1/4”NPT)
BOTTOM
Model
Configuration
Illustration
TRW02ST
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
11
SE+ Series Featuring ThermaCirc360™ 2-Unit Wall-Hanging Frame (Continued)
Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs
TRW02STi TRW02STe RUR199i AND RU199i (NG/LP) RUR199e AND RU199e (NG/LP) 66 X 70 X 35 178 177 399 398
Rack Frame - Specifications 14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray
Frame Material Frame Finish Color
16 Gauge Stainless Steel 1.5” Square Tube Stainless Stainless
Water & Gas Connections Hot Water Trunk Line Diameter
2"
Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type
2" Rigid Copper Rigid Copper 2" PIPE 1-1/4" 1-1/4” MNPT
Gas Trunk Line Material
Sch 40 Steel
Gas Branch Line Material Electric Requirements Voltage
PVC Over CSST AC 120 Volts—60 Hz
Maximum Current (Amperes)
8
BTU and Flow Rates for RUR199i, RUR199e, RU199i, RU199e (NG/LP) Number of Tankless Water Heaters
2
Flow rate @ 70°F rise (gpm)
10.8
Flow rate @ 100°F rise (gpm)
7.6
Minimum input rate (Btuh)
15,200
Maximum input rate (Btuh)
398,000
TRW02ST
12
Rinnai Tankless Rack System Specification Sheet
WALL-HANGING RACKS → SE+ SERIES FEATURING THERMACIRC360™
SE+ Series Featuring ThermaCirc360™
3-Unit Wa l l - H a n g i n g F r a m e
FRONT
LEFT
BACK
BOTTOM
Model
Configuration
Illustration
TRW03ST
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
13
SE+ Series Featuring ThermaCirc360™ 3-Unit Wall-Hanging Frame (Continued) Model
TRW03STi
Water Heater Model
TRW03STe
RUR199i AND RU199i (NG/LP)
Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs Rack Frame - Specifications Frame Material Frame Finish Color
RUR199e AND RU199e (NG/LP)
66 x 70 x 35 258 476
254 472
14 Gauge Hot Rolled Steel 1.5” Square Tube
16 Gauge Stainless Steel 1.5” Square Tube
Powder Coat
Stainless
Gray
Stainless
Water & Gas Connections Hot Water Trunk Line Diameter
2"
Cold Water Trunk Line Diameter
2"
Hot Water Trunk Line Material
Rigid Copper
Cold Water Trunk Line Material
Rigid Copper
Water Trunk Connection Type
2" PIPE
Gas Trunk Line Diameter
1-1/4"
Gas Trunk Connection Type
1-1/4” MNPT
Gas Trunk Line Material
Sch 40 Steel
Gas Branch Line Material
PVC Over CSST
Electric Requirements Voltage
AC 120 Volts—60 Hz
Maximum Current (Amperes)
12
BTU and Flow Rates for RUR199i, RUR199e, RU199i, RU199e (NG/LP) Number of Tankless Water Heaters
3
Flow rate @ 70°F rise (gpm)
16.2
Flow rate @ 100°F rise (gpm)
11.4
Minimum input rate (Btuh)
15,200
Maximum input rate (Btuh)
597,000
TRW03ST
14
Rinnai Tankless Rack System Specification Sheet
WALL-HANGING RACKS → HE SERIES
HE Series
2-Unit Wa l l - H a n g i n g F r a m e
FRONT
LEFT
BACK
38.50 30.50 5.65
15.00
49.10
11.50 HOT (2”COPPER) 7.50 COLD (2”COPPER) 3.25 GAS (1-1/4”NPT)
30.50
BOTTOM
Model
Configuration
Illustration
TRW02HE
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
15
HE Series 2-Unit Wall-Hanging Frame (Continued) Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs
TRW02HEi
TRW02HEXi
TRW02HEe
RL94i (NG/LP)
RLX94i (NG) 66 x 67 x 35 120 334
RL94e (NG/LP)
120 334
120 334
Rack Frame - Specifications Frame Material
14 Gauge Hot Rolled Steel 1.5” Square Tube
Frame Finish Color
16 Gauge Stainless Steel 1.5” Square Tube
Powder Coat
Stainless
Gray
Stainless
Water & Gas Connections Hot Water Trunk Line Diameter
1-1/2"
Cold Water Trunk Line Diameter
1-1/2"
Hot Water Trunk Line Material
Rigid Copper
Cold Water Trunk Line Material
Rigid Copper
Water Trunk Connection Type
1-1/2" PIPE
Gas Trunk Line Diameter
1-1/4"
Gas Trunk Connection Type
1-1/4” MNPT
Gas Trunk Line Material
Sch 40 Steel
Gas Branch Line Material
PVC Over CSST
Electric Requirements Voltage
AC 120 Volts—60 Hz
Maximum Current (Amperes)
8 BTU and Flow Rates for RL94i, RLX94i, RL94e (NG/LP)
Number of Tankless Water Heaters
2
2
2
Flow rate @ 70°F rise (gpm)
9.5
9
9.5
Flow rate @ 100°F rise (gpm)
6.6
6.3
6.6
Minimum input rate (Btuh)
10,300
10,300
10,300
Maximum input rate (Btuh)
398,000
384,000
398,000
TRW02HE / TRW02HEX
16
Rinnai Tankless Rack System Specification Sheet
WALL-HANGING RACKS → HE SERIES
HE Series
3-Unit Wa l l - H a n g i n g F r a m e FRONT
LEFT
BACK
BOTTOM
Model
Configuration
Illustration
TRW03HE
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
17
HE Series 3-Unit Wall-Hanging Frame (Continued)
Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs
TRW03HEi
TRW03HEXi
TRW03HEe
RL94i (NG/LP)
RLX94i (NG) 66 x 67 x 35 160 374
RL94e (NG/LP)
160 374
160 374
Rack Frame - Specifications Frame Material
14 Gauge Hot Rolled Steel 1.5” Square Tube
16 Gauge Stainless Steel 1.5” Square Tube
Powder Coat
Stainless
Gray
Stainless
Frame Finish Color Water & Gas Connections Hot Water Trunk Line Diameter
1-1/2"
Cold Water Trunk Line Diameter
1-1/2"
Hot Water Trunk Line Material
Rigid Copper
Cold Water Trunk Line Material
Rigid Copper
Water Trunk Connection Type
1-1/2" PIPE
Gas Trunk Line Diameter
1-1/4"
Gas Trunk Connection Type Gas Trunk Line Material
1-1/4” MNPT Sch 40 Steel
Gas Branch Line Material
PVC Over CSST
Electric Requirements Voltage
AC 120 Volts—60 Hz
Maximum Current (Amperes)
12 BTU and Flow Rates for RL94i, RLX94i, RL94e (NG/LP)
Number of Tankless Water Heaters
3
3
3
Flow rate @ 70°F rise (gpm)
14
13.5
14
Flow rate @ 100°F rise (gpm)
9.8
9.4
9.8
Minimum input rate (Btuh)
10,300
10,300
10,300
Maximum input rate (Btuh)
597,000
576,000
597,000
TRW03HE / TRW03HEX
18
Rinnai Tankless Rack System Specification Sheet
WALL-MOUNT RACKS Available Configurations • 2-Units • 3-Units
2-Unit Wa l l - M o u n t F r a m e LEFT
FRONT
BACK
47.00 20.50 5.91 TYP
BOTTOM
Model
Configuration
Illustration
TRS02ILWCU
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
19
2-Unit Wall-Mount Frame (Continued) Model
TRS02ILWCU CU199i, CU199e (NG/LP)
Water Heater Model Crate Dimensions (HxLxD) - in
66 x 70x 35
Weight - Fully Assembled - lbs
208
Weight - Shipping (total) - lbs Rack Frame - Specifications Frame Rail Type
410 Sheet Metal Aluminum (0.090 5052-H32)
Frame Material Frame Finish
Powder Coat
Color
Gray
Water & Gas Connections Hot Water Trunk Line Diameter Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type
2" 2" Rigid Copper Rigid Copper 2" PIPE 1-1/4" 1-1/4” MNPT
Gas Trunk Line Material
Sch 40 Steel
Gas Branch Line Material Electric Requirements
PVC Over CSST
Voltage
AC 120 Volts—60 Hz
Maximum Current (Amperes)
8 BTU and Flow Rates for CU199i, CU199e (NG/LP)
Number of Tankless Water Heaters
2
Flow rate @ 70°F rise (gpm)
10.8
Flow rate @ 100°F rise (gpm)
7.6
Minimum input rate (Btuh)
15,200
Maximum input rate (Btuh)
398,000
TRS02ILWCU
20
Rinnai Tankless Rack System Specification Sheet
3-Unit Wa l l - M o u n t F r a m e
FRONT
LEFT
BACK
BOTTOM
Model
Configuration
Illustration
TRS03ILWCU
TRS23ILWCU
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
21
3-Unit Wall-Mount Frame (Continued) Model
TRS03ILWCU
Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs Rack Frame - Specifications
TRS23ILWCU
CU199i, CU199e (NG/LP) 66 x 70 x 35 297
222
497
424
Frame Rail Type
Sheet Metal
Frame Material
Aluminum (0.090 5052-H32)
Frame Finish Color
Powder Coat Gray
Water, Gas, and Condensate Connections Hot Water Trunk Line Diameter
2"
Cold Water Trunk Line Diameter Hot Water Trunk Line Material
2" Rigid Copper
Cold Water Trunk Line Material
Rigid Copper
Water Trunk Connection Type Gas Trunk Line Diameter
2" PIPE 1-1/4"
Gas Trunk Connection Type
1-1/4” MNPT
Gas Trunk Line Material Gas Branch Line Material
Sch 40 Steel PVC Over CSST
Condensate Trunk Line Diameter
3/4”
N/A
Condensate Trunk Line Material
Sch–40 PVC
N/A
3/4” Pipe
N/A
Condensate Trunk Connection Type Electric Requirements Prewired Electrical Assembly Voltage
Yes (Indoor Models Only) AC 120 Volts—60 Hz
Maximum Current (Amperes)
12
N/A 8
BTU and Flow Rates for CU199i, CU199e (NG/LP)
Number of Tankless Water Heaters
3
2
Flow rate @ 70°F rise (gpm)
16.2
10.8
Flow rate @ 100°F rise (gpm)
11.4
7.6
Minimum input rate (Btuh)
15,200
15,200
Maximum input rate (Btuh)
597,000
398,000
TRS03ILWCU
22
TRS23ILWCU
Rinnai Tankless Rack System Specification Sheet
CORNER-HANGING RACKS Available Configurations • 2-Units
2-Unit Corner-Hanging Frame TOP
FRONT
Model
Configuration
Illustration
TRC02CU
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
23
2-Unit Corner-Hanging Frame (Continued)
Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs
TRC02CUi CU199i (NG/LP) 31.5 x 48 x 50 224 356
Rack Frame - Specifications Frame Material Frame Finish Color
14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray
Water & Gas Connections Hot Water Trunk Line Diameter
1-1/2"
Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type
1-1/2" Rigid Copper Rigid Copper 1-1/2" PIPE 1-1/4" 1-1/4” MNPT
Gas Trunk Line Material Gas Branch Line Material Electric Requirements Voltage Maximum Current (Amperes) Number of Tankless Water Heaters
Sch 40 Steel PVC Over CSST AC 120 Volts—60 Hz 8 BTU and Flow Rates for CU199i, (NG/LP) 2
Flow rate @ 70°F rise (gpm)
10.8
Flow rate @ 100°F rise (gpm)
7.6
Minimum input rate (Btuh) Maximum input rate (Btuh)
24
15,200 398,000
Rinnai Tankless Rack System Specification Sheet
FREE-STANDING RACKS Available Configurations • 2-Units, 3-Units, 4-Units, 5-Units, 6-Units
4-Unit Free-Standing Frame FRONT
LEFT
20.50
18.81
5.92 TYP
56.82
4.50 GAS (1-1/4”NPT) 9.38 COLD (2”COPPER)
34.53
14.38 HOT (2”COPPER)
26.29 28.59 BOTTOM
Model
Configuration
Illustration
Model
Configuration
Illustration
Inline
TRS02ILCU (facing same
TRS04CU
direction)
TRS02CU
TRS03CU
Back to Back
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
25
4-Unit Free-Standing Frame (Continued)
Model
TRS04CU
TRS03CU
Water Heater Model
TRS02CU
TRS02ILCU
CU199i, CU199e (NG/LP)
Crate Dimensions (HxLxD) - in
66 x 70 x 35
Weight - Fully Assembled - lbs
365
290
214
214
Weight - Shipping (total) - lbs
562
490
416
416
Rack Frame - Specifications Frame Rail Type
Sheet Metal
Frame Material
Aluminum (0.090 5052-H32)
Frame Finish
Powder Coat
Color
Gray
Water & Gas Connections Hot Water Trunk Line Diameter
2”
Cold Water Trunk Line Diameter
2”
Hot Water Trunk Line Material
Rigid Copper
Cold Water Trunk Line Material
Rigid Copper
Water Trunk Connection Type
2” PIPE
Gas Trunk Line Diameter
1-1/4”
Gas Trunk Connection Type
1-1/4” MNPT
Gas Trunk Line Material
Sch 40 Steel
Gas Trunk Branch Line Material
PVC Over CSST
Condensate Trunk Line Diameter
3/4”
N/A
Sch-40 PVC
N/A
3/4” Pipe
N/A
Yes (Indoor Models Only)
N/A
Condensate Trunk Material Condensate Trunk Connection Type Electric Requirements
Prewired Electrical Assembly Voltage Maximum Current (Amperes)
AC 120 Volts—60 Hz 16
12
8
BTU and Flow Rates for CU199i, CU199e (NG/LP) Number of Tankless Water Heaters
4
3
2
Flow rate @ 70°F rise (gpm)
21.6
16.2
10.8
Flow rate @ 100°F rise (gpm)
15.2
11.4
7.6
796,000
597,000
Minimum input rate (Btuh) Maximum input rate (Btuh)
TRS04CU
26
15,200
TRS03CU
398,000
TRS02CU
TRS02ILCU
Rinnai Tankless Rack System Specification Sheet
6-Unit Free-Standing Frame LEFT
FRONT
BOTTOM
Model
Configuration
Illustration
Model
TRS06CU
TRS36CU
TRS05CU
TRS46CU
TRS03ILCU
TRS23ILCU
Configuration
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Illustration
27
6-Unit Free-Standing Frame (Continued)
Rack Frame - Specifications Frame Rail Type
Sheet Metal
Frame Material Frame Finish
Aluminum (0.090 5052-H32) Powder Coat
Color
Gray
Water & Gas Connections Hot Water Trunk Line Diameter
2-1/2"
2”
Cold Water Trunk Line Diameter
2-1/2"
2” Rigid Copper Rigid Copper
Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type
2-1/2” PIPE
2” PIPE
Gas Trunk Line Diameter Gas Trunk Connection Type
1-1/2" 1-1/2” MNPT
1-1/4” 1-1/4”MNPT
Gas Trunk Line Material Gas Branch Line Material
Sch 40 Steel PVC Over CSST
Condensate Trunk Line Diameter
3/4”
N/A
Condensate Trunk Line Material
Sch-40 PVC
N/A
3/4” Pipe
N/A
Condensate Trunk Connection Type Electric Requirements Prewired Electrical Assembly
Yes (Indoor Models Only)
Voltage
N/A
AC 120 Volts—60 Hz
Max Current (Amperes)
24
20
16
12
12
8
BTU and Flow Rates for CU199i, CU199e (NG/LP)
Number of Tankless Water Heaters
6
5
3
4
2
Flow rate @ 70°F rise (gpm)
32.4
27.0
16.2
21.6
10.8
Flow rate @ 100°F rise (gpm)
22.8
19.0
11.4
15.1
7.6
796,000
398,000
Minimum input rate (Btuh) Maximum input rate (Btuh)
TRS06CU
28
TRS05CU
15,200 1,194,000
TRS03ILCU
995,000
TRS36CU
597,000
TRS46CU
TRS23ILCU
Rinnai Tankless Rack System Specification Sheet
Venting Venting components are packaged separately from the pre-assembled rack for field assembly of the vent system by the contractor. The following vent options are available: • Direct Vent with Concentric Pipe IMPORTANT HE+ Series tankless water heaters must use concentric venting with a metal exhaust pipe. Refer to the Installation and Operation Manual supplied with the HE+ Tankless Water Heater for venting options. • •
Direct Vent with Twin Pipe Common Vent
Direct Vent (Concentric Pipe)
Direct Vent (Twin Pipe)
Combustion air and exhaust vent directly through a single concentric connection. Hot exhaust exits through the interior tube, while combustion air enters through the outer layer.
Combustion air and exhaust vent directly through separate penetrations. Exhaust Combustion air
Exhaust Combustion air
Combustion air
Common Vent
(Indoor Units Only. Direct Vent and Non-Direct/Room Air Vent)
Direct Vent
Non-Direct (Room Air) Vent
Multiple water heaters sharing a combustion air header and a separate exhaust header that vents directly through separate penetrations to the outside.
Multiple water heaters using room air for combustion while sharing an exhaust header that vents directly to the outside.
Exhaust
Exhaust
Combustion Air Room Air For Combustion
Rinnai Tankless Rack System Specification Sheet
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
29
Vent Options The following table lists the vent options for the CU Series, SE Series and SE+ Series tankless water heaters. HE+ Series tankless water heaters must use concentric venting with a metal exhaust pipe. Refer to the Installation and Operation Manual supplied with the HE+ Tankless Water Heater for venting options.
Vent Options for CU Series, SE Series, and SE+ Series Tankless Water Heaters Vent Options
Common Vent
Vent Material Exhaust
Polypropylene or Schedule 40 PVC/CPVC
Intake
Polypropylene or Schedule 40 PVC/CPVC
Diameter
Max. Units
Maximum Vent Length
3 in.
2
65 FT
4 in.
4
1-3 Units: 150 FT 4 Units: 65 FT
7
1-6 Units: 150 FT 7 Units: 70 FT
8
150 FT
Header Vent
4 in.
6 in.
6 in.
Concentric Pipe
Twin Pipe
Polypropylene
Polypropylene* or Schedule 40 PVC/CPVC
Schedule 40 PVC
Schedule 40 PVC/CPVC
5 in.
150 FT 1
4 in.
65 FT
3 in.
150 FT 1
2 in.
65 FT
* Twin Pipe Polypropylene venting is provided by Centrotherm through their own distribution network.
Multiple Water Heaters With use of cascade cable(s) up to 24 water heaters can be electronically connected. This connection will rotate water heater operation order to ensure equal usage among the entire system and enables all water heaters connected to modulate operation and function as one hot water source.
30
Rinnai Tankless Rack System Specification Sheet
COMMON VENT SYSTEM Features and Benefits The CVent Common Venting system provides longer vent lengths and fewer wall or roof penetrations than conventional single-unit venting. For the exhaust flue, CVent utilizes a CSA certified and tested venting (PPTL) and for Canada ULC-S636-certified and tested venting (PPS) material from Ubbink, the same supplier for Rinnai's innovative line of concentric venting. The various sections are self locking and sealing and can be pushed together without use of cement or glue. CVent is for use in U.S. and Canada only. PPTL components are certified for U.S. installations whereas PPS components are certified for Canadian installations.
Model Applicability The common vent system is CSA certified (ANSI Z21.10.3, Gas Water Heaters Standards) for use with the following Rinnai tankless condensing water heaters only: RU98i (REU-KB3237FFUD-US), RUC98i (REU-KBD3237FFUD-US), and C199i (REU-KBD3237FFUDC-US)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 1 SP-CV-4
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
COMMON VENT SYSTEM Maximum Equivalent Vent Length When determining equivalent exhaust and intake vent lengths add:
• •
•
6 feet for each 90° elbow
•
3 feet for each 45° elbow
Add any vent extension lengths which are added within the header due to increased spacing of the water heaters Header kits have already been counted and do not need to be added.
Tankless Rack System (TRS) Venting Configuration Summary (PPTL & PPS) TRS Configuration
Tankless Models
# of Tankless Units
Minimum Equivalent Vent Length (Ft)
Maximum Equivalent Vent Length (Ft)
Exhaust*
Exhaust*
Intake*
8
8 7 2 to 6
C199i (REU-KBD3237FFUDC-US); RUC98i (REU-KBD3237FFUD); RU98i (REU-KB3237FFUD-US)
8
One Elbow + Termination
2 to 6
Intake*
Vent Option
Appliance Adapter
Room Air Configuration
Exhaust Position
41 Appliance Adapter
7 C199i (REU-KBD3237FFUDC-US)
Approved C-Vent Configuration
80 100
9
41
41
80
80
100
100
41
41
15 2 to 7
100
100
Parallel Pipe Configuration (Different Pressure Zone) (Page 23) Parallel Pipe Configuration (Same Pressure Zone & Face the Same Direction) (Page 23)
Vertical Only
Vertical or Horizontal
*Approved exhaust and intake diameter is 8 inches.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 2 SP-CV-4
COMMON VENT SYSTEM When ordering the CVent exhaust components and the Tankless Rack System (TRS) together, please use the following table and part numbers.
Direct Vent 8" Common Venting Direct Vent Common Venting Description 8" back-to-back 3 unit header kit 8" back-to-back 4 unit header kit 8" back-to-back 5 unit header kit 8" back-to-back 6 unit header kit 8" back-to-back 7 unit header kit 8" back-to-back 8 unit header kit 8" in-line 3 unit header kit 8" in-line 4 unit header kit 8" in-line 5 unit header kit 8" in-line 6 unit header kit 8" in-line 7 unit header kit 8" in-line 8 unit header kit
Back-to-Back Configuration
U.S. (PPtl)
Canada (PPs)
Item Number
Item Number
CV8BB3USDV CV8BB4USDV CV8BB5USDV CV8BB6USDV CV8BB7USDV CV8BB8USDV CV8IL3USDV CV8IL4USDV CV8IL5USDV CV8IL6USDV CV8IL7USDV CV8IL8USDV
CV8BB3CADV CV8BB4CADV CV8BB5CADV CV8BB6CADV CV8BB7CADV CV8BB8CADV CV8IL3CADV CV8IL4CADV CV8IL5CADV CV8IL6CADV CV8IL7CADV CV8IL8CADV
In-line Configuration
Key: CV = common vent; 8 = 8 inch diameter; IL/BB= stand alone/back-to-back; US/CA = United States/Canada; DV/RA = direct vent/room air; 4/5/6/7/8 = no. of water heaters
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 3 SP-CV-4
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
COMMON VENT SYSTEM Room Air 8" Common Venting U.S. (PPtl)
Canada (PPs)
Item Number
Item Number
8" back-to-back 3 unit header kit 8" back-to-back 4 unit header kit
CV8BB3USRA CV8BB4USRA
CV8BB3CARA CV8BB4CARA
8" back-to-back 5 unit header kit
CV8BB5USRA
CV8BB5CARA
8" back-to-back 6 unit header kit
CV8BB6USRA
CV8BB6CARA
8" back-to-back 7 unit header kit
CV8BB7USRA
CV8BB7CARA
8" back-to-back 8 unit header kit
CV8BB8USRA
CV8BB8CARA
8" in-line 3 unit header kit
CV8IL3USRA
CV8IL3CARA
8" in-line 4 unit header kit
CV8IL4USRA
CV8IL4CARA
8" in-line 5 unit header kit
CV8IL5USRA
CV8IL5CARA
8" in-line 6 unit header kit
CV8IL6USRA
CV8IL6CARA
8" in-line 7 unit header kit
CV8IL7USRA
CV8IL7CARA
8" in-line 8 unit header kit
CV8IL8USRA
CV8IL8CARA
Room Air Common Venting Description
Back-to-Back Configuration
In-line Configuration
Key: CV = common vent; 8 = 8 inch diameter; IL/BB= stand alone/back-to-back; US/CA = United States/Canada; DV/RA = direct vent/room air; 4/5/6/7/8 = no. of water heaters
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 4 SP-CV-4
COMMON VENT SYSTEM CVent Starter Kit 790005 / 791008PPS* 8-Inch For Back-to-Back or In-line Combustion Air & Exhaust
1
2
3
4
7
NO
QTY
PPTL PART #’S
*PPS PART #’S
1
1
DESCRIPTION CVENT ENDPIECE (EXHAUST) W/ CLEANOUT & CONDENSATE DRAIN (32mm)
790042
NA
2
1
CVENT COMB AIR ENDPIECE D8
780046
NA
3
1
CVENT CONDENSATE TRAP (32mm Connection)
790048
NA
4
1
CVENT DRAIN HOSE AND CLAMPS
790049
NA
6
1
UBBINK INSTALLATION INSTRUCTION
NA
NA
7
1
CENTROCERIN LUBRICANT
NA
NA
CVent In-line Kit 790007 / 791009PPS* 8-Inch Header Kit For In-line Combustion Air & Exhaust
1
2
3
4
Ø4”
5
7
6 Ø3”
NO QTY DESCRIPTION
PPTL PART #’S
*PPS PART #’S
1
1
CVENT COLLECTOR, 1 CONNECTION, D8 X L20 X D4 (Exhaust)
790040
NA
2
1
CVENT ELBOW D4 X 87° WITH CLEANOUT
790039
NA
3
1
CVENT EXTENSION, D4 X L18
790035
NA
4
1
CVENT APPLIANCE ADAPTER WITH CHECK VALVE AND HOSE TRAP
790038
NA
5
1
CVENT COMB. AIR COLLECTOR, 1 CONNECTION, D8 X L20 X D3
780044
NA
6
1
CVENT COMB AIR FLEX FITTING, D3
780050
NA
7
1
CENTROCERIN LUBRICANT
NA
NA
*PPS kits and components are certified for use in Canada
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 5 SP-CV-4
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
COMMON VENT SYSTEM CVent Back-2-Back Kit 790008 / 791010PPS 8-Inch Header Kit For Back-to-Back Combustion Air & Exhaust 1
5
Ø4”
Ø3”
Ø3”
Ø4”
2
4
3
6
7
PPTL PART #’S
*PPS PART #’S
1
NO QTY DESCRIPTION 1
CVENT COLLECTOR, 2 CONNECTION, D8 X L20
790041
NA
2
2
CVENT ELBOW D4 X 87° WITH CLEANOUT
790039
NA
3
2
CVENT EXTENSION, D4 X L18
790035
NA
4
2
CVENT APPLIANCE ADAPTER WITH CHECK VALVE AND HOSE TRAP
790038
NA
5
1
CVENT COMB. AIR COLLECTOR, 2 CONNECTION, D8 X L20 X D3
780045
NA
6
2
CVENT COMB. AIR FLEX FITTING, D3
780050
NA
7
1
CENTROCERIN LUBRICANT
NA
NA
*PPS kits and components are certified for use in Canada
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 6 SP-CV-4
COMMON VENT SYSTEM CVent Starter Kit-Room Air 790058 / 791011PPS* 8-Inch For Back-to-Back or In-line Combustion Air & Exhaust (Room air is only for C199i in Commercial Common Vent Applications) 1
2
3
6
NO QTY DESCRIPTION
PPTL PART #’S
*PPS PART #’S
1
1
CVENT ENDPIECE (EXHAUST) W/ CLEANOUT & CONDENSATE DRAIN (32mm)
790042
NA
2
1
CVENT CONDENSATE TRAP (32mm Connection)
790048
NA
3
1
CVENT DRAIN HOSE AND CLAMPS
790049
NA
5
1
UBBINK INSTALLATION INSTRUCTION
NA
NA
6
1
CENTROCERIN LUBRICANT
NA
NA
CVent In-line Kit-Room Air 790059 / 791012PPS* 8-Inch Header Kit For In-line Combustion Air & Exhaust (Room air is only for C199i in Commercial Common Vent Applications) 1
1
Ø4”
2
3
2 Ø4”
3 4
NO QTY DESCRIPTION
4
5
PPTL PART #’S
*PPS PART #’S
1
1
CVENT COLLECTOR, 1 CONNECTION, D8 X L20 X D4 (Exhaust)
790040
NA
2
1
CVENT ELBOW D4 X 87° WITH CLEANOUT
790039
NA
3
1
CVENT EXTENSION, D4 X L18
790035
NA
4 5
1 1
CVENT APPLIANCE ADAPTER (ROOM AIR), CHECK VALVE, HOSE TRAP CENTROCERIN LUBRICANT
NA NA
NA NA
*PPS kits and components are certified for use in Canada
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 7 SP-CV-4
COMMON VENT SYSTEM CVent Back-to-Back Kit-Room Air 790060 / 791013PPS* 8-Inch Header Kit For Back-2-Back Combustion Air & Exhaust (Room air is only for C199i in Commercial Common Vent Applications)
2 1
1
2
Ø4”
3 Ø4”
4
3
4
5
PPTL PART #’S
*PPS PART #’S
1
1
CVENT COLLECTOR, 2 CONNECTION, D8 X L20
790041
NA
2
2
CVENT ELBOW D4 X 87° WITH CLEANOUT
790039
NA
3
2
CVENT EXTENSION, D4 X L18
790035
NA
4
1
CVENT APPLIANCE ADAPTER (ROOM AIR), CHECK VALVE, HOSE TRAP
NA
NA
5
1
CENTROCERIN LUBRICANT
NA
NA
NO QTY
DESCRIPTION
*PPS kits and components are certified for use in Canada
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 8 SP-CV-4
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
COMMON VENT SYSTEM
Termination Kits Cvent 8-in Roof Termination Kit 790057 / 791007PPS (can be used as Intake or Exhaust)
If roof termination is being used as intake the assembly must include the intake rain cap Centrocerin Lubricant
CVent 8-in Roof Termination (Outer shell: available in PPtl or PPS)
Cvent 8-in Wall Termination Kit (Combustion Air & Exhaust) 790004 (for use with PPtl and PPS material) Ø0.24” (Qty. 4) 31”
Ø7.89”
Ø12.2”
Centrocerin lubricant
Interior Slip Fit Wall Plate
(Material: Stainless Steel)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 9 SP-CV-4
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
COMMON VENT SYSTEM
COMMON VENT COMPONENTS
CVent Elbow D8x90 degree #790023 / 791003PPS
CVent Elbow D8x45 degree
Inverter Coupling Kit With Condensate Trap #790032
CVent 8in Vent Rain Cap (Intake) #780053
CVent Elbow D8x90 degree Vertical Support #790029
CVent Extension D8xL18” #790020, D8xL39” #790021 / 791001PPS D8xL78” #790052 / 791006PPS
CVent 8in Vent Rain Cap (Exhaust) #790034
CVent Flat Roof Flashing #790002
Combustion Air PVC Adapter Kit #780037
CVent 8-in Bracket #790024
CVent 8-in Chase Cover #790030
CVent 8in Vent Distancer #790031
CVent Extension D4xL18” #790035 / 791004PPS D8xL39” #790028
CVent Pitched Roof Flashing (Including Storm Collar) #790003
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 10 SP-CV-4
COMMON VENT SYSTEM Intake Material Options for Combustion Air Vent:
•For extended Intake pipe runs, PVC can be used between the Intake Header and Termination. •Use the PVC adapter (described below) when transitioning from the PPTL/PPS intake header to the stainless steel Combustion Air Termination.
WARNING
The materials described below can only be used on the combustion air vent. The Ubbink Polypropylene CVent can be used on both the combustion air and exhaust. Field supplied PVC material can only be used on the combustion air side and MUST NOT be used for the exhaust.
Item Description
Approval Codes for Installation
Flue Material
United States Plastic Vent and/or combustion air components
PVC Schedule 40
ANSI/ASTM D1785
PVC - DWV
ANSI/ASTM D2665
CPVC Schedule 40
ANSI/ASTM F441
PVC
ANSI/ASTM D2564
CPVC
ANSI/ASTM F493
Plastic pipe cement and primer
•
Combustion Air PVC Adapter Kit (Part #: 790037) includes both a transition from the 8” (200mm) PP header to 8” PVC and an 8”PVC to 8” (200mm) termination PP to PVC ADAPTER: 8” (200mm) PP header to 8” PVC
PVC to TERMINATION ADAPTER: 8”PVC to 8” (200mm) termination
FIELD SUPPLIED PVC PIPE
Plastic pipe cement and primer
•
Fasten, secure, and support all vent materials using manufacturer and industry standards to avoid potential intake air leaks or blockage. Support horizontal vent runs a minimum of every 4 feet and all vertical vent runs a minimum of every 6 feet.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 11 SP-CV-4
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
COMMON VENT SYSTEM Terminations This appliance is only certified to use Rinnai terminations and mounted in the orientation shown below. Horizontal Termination Combustion Air Vent
Min 36”
Exhaust Vent
Min 36”
Combustion Air Vent
The exhaust and intake terminations must follow these clearances: [1] 12 inch minimum vertically from bottom of combustion air termination to ground or anticipated snow line.
INTAKE IS NOT ALLOWED WITHIN THE SHADED AREA
Combustion Air Vent Combustion Air Vent
Min 12” above grade or anticipated snow level
[2] From edge of exhaust termination to edge of intake termination: Minimum of 36 inches Maximum of 20 feet
Min 36” Max 20’
Combustion Air Vent
[3] 36 inch minimum from multiple exhaust CVents There should be a minimum of 36 inches between exhaust terminations in multiple common vent installations. The vent (exhaust and combustion air) terminations to be as specified in table in “Maximum Equivalent Vent Length” Section (model specific).
NOTE: During colder weather when the exhaust temperature is much hotter than the outside air, the exhaust fumes condense producing water vapor. As a result a plume of water vapor may be seen leaving the exhaust.
EXHAUST - CVent
MAXIMUM 20’ MINIMUM 36”
INTAKE - PVC
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 12 SP-CV-4
Installation Venting Components for Use with SE+, SE, HE+ (Condensing & Non-Condensing), Commercial Tankless Water Heaters & Boilers Product ID
Product Description
List Price (U.S.)
146141
Roof Flashing Assembly Flat
$40
169044
Pipe Clamp Universal Plastic
$7
189950
Shingle Roof Flashing, 1/12 to 6/12 pitch
$71
189951
Shingle Roof Flashing, 6/12 to12/12 pitch
$71
189952
Shingle Roof Flashing, 8/12 to16/12 pitch
$71
222053
Condensate Trap, Version II
$48
224042
Universal Bug Guard
$130
224045
3 in. / 5 in. Thimble (1 piece per box)
$58
224049
3 in. / 5 in. Vent Support Bracket
$43
242141
Flashing for Metal Roof
$136
710342
3 in. / 5 in. Rubber Wall Plate White
$7
710602
3 in. / 5 in. Rubber Wall Plate Black
$7
50171949
Tile/Shingle Roof Flashing, 1/12 to 6/12
$78
50171954
Tile/Shingle Flashing, 8/12 to 16/12
$78
50171961
Tile/Shingle Flashing, 6/12 to 12/12
$78
102000012
3 in. / 5 in. Horizontal Flashing Panel
$14
222716
2 in. Pipe Clamp Plastic (Qty 10) (SENSEI™ SE+ ONLY)
$28
224055
2 in. / 4 in. Thimble (SENSEI™ SE+ ONLY)
$52
710265
2 in. / 4 in. Rubber Wall Plate White (SENSEI™ SE+ ONLY)
$6
710192
2 in. / 4 in. Rubber Wall Plate Black (SENSEI™ SE+ ONLY)
$6
169013
2 in. / 4 in. Pipe Clamp Metal (SENSEI™ SE+ ONLY)
$6
224056
2 in. / 4 in. Vent Support Bracket (SENSEI™ SE+ ONLY)
$39
169043
3 in. / 5 in. Pipe Clamp Metal (SENSEI™ SE+ ONLY)
$7
2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
Installation Venting Components for Use with HE+ (Former Luxury) and HE (Former Value) Series Tankless Water Heaters (Non-Condensing) Concentric Venting Termination & Termination Kits for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) Product ID
Product Description
List Price (U.S.)
184127
Roof Discharge Termination 18 in. (above roof)
$125
224046
Raised Horizontal Termination Kit (“Snorkel”)
$545
223191
8.7 in. Universal Non-Condensing Horizontal Termination Kit
$91
223181
11.5 in. Universal Non-Condensing Horizontal Termination Kit
$114
223183
11.5 in. Universal Non-Condensing Horizontal Termination
$62
223182
21 in. Universal Non-Condensing Horizontal Termination Kit
$120
223184
21 in. Universal Non-Condensing Horizontal Termination
$69
223187
21 in. Non-Condensing Horizontal Termination Diverter Kit Termination for Minimal Clearance
$120
185342
Roof Termination Ext Kit
$70
224054
Telescoping Vent Length
$60
184118-S
Roof Discharge Termination 18 in. (above roof)
$104
184119
Roof Discharge Termination 38 in. (above roof); cold climate
$145
223188
12 in. Universal Termination Metal Kit
$136
Concentric Venting Elbow Components for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) 224063
90 Degree Elbow
$52
224050
45 Degree Elbow (Qty of 2)
$71
224255
90 Degree Elbow (Metal)
$60
224250
45° Elbow (Metal)
$85
Concentric Venting Vent Pipe Extensions for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) 224051
10 in. Vent Pipe Extension
$41
224052
19.5 in. Vent Pipe Extension
$58
224053
39 in. Vent Pipe Extension
$64
224260
10 in. Vent Pipe Extension (Metal)
$52
224265
19.5 in. Vent Pipe Extension (Metal)
$69
224270
39 in. Vent Pipe Extension (Metal)
$79
Installation Accessories for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) 222053
Condensate Trap
$48
224245
Condensate Collector
$77
2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
3 in. / 5 in. Installation Venting Components for Use with SE+ and SE Tankless Water Heaters (Condensing) and M, E, Q Series Boilers Product ID
Product Description
List Price (U.S.)
184162PP
3 in. / 5 in. Condensing Roof Discharge Termination 20in Above Roof
$90
185344PP
3 in. / 5 in. Roof Termination Extension Kit
$70
185346PP
3 in. / 5 in. Condensing Termination Extension
$82
185347PP
Separation Kit
$28
187585PP
Twin Pipe Adapter for use w/ PVC/CPVC (Special Order Only)
$60
223174PP
3 in. / 5 in. Condensing Horizontal Term Kit 8.7 in.
$84
223176PP
3 in. / 5 in. Condensing Horizontal Term Kit 12 in.
$90
223177PP
3 in. / 5 in. Condensing Horizontal Term Kit 21 in.
$94
223186PP
3 in. / 5 in. Condensing Horizontal Term Diverter Kit 19 in.
$100
224047PP
3 in. / 5 in. Condensing Raised Horiz Term Kit Snorkel
$380
224077PP
3 in. / 5 in. Condensing 45 Degree Elbow (Qty 2)
$50
224078PP
3 in. / 5 in. Condensing 90 Degree Vent Pipe Elbow
$36
224079PP
3 in. / 5 in. Condensing Vent Pipe Extension 19.5 in.
$40
224080PP
3 in. / 5 in. Condensing Vent Pipe Extension 39 in.
$47
224087PP
3 in. / 5 in. Condensing Vent Pipe Extension 10 in.
$32
196116PVC
3 in. Concentric PVC
$87
196985PVC
3 in. Low Profile PVC
$27
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. • “PP” at the end of the part number signifies Polypropylene venting components for use with SE and SE+ Condensing Tankless Water Heaters and Condensing Gas Boilers (M, E, Q Series) Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
2 in. / 4 in. Installation Venting Components for Use with SENSEI™ SE+ Tankless Water Heaters (Condensing) and M-Series Boilers SENSEI™ Tankless Models
M-Series Condensing Boilers
RU130
RU199
M060SN
M160SN
M120CN
RU160
RUR160
M090SN
M060CN
M160CN
RU180
RUR199
M120SN
M090CN
CU160
CU199
Product ID
Product Description
List Price (U.S.)
222710NPP
2 in. Condensing 45 Degree Elbow (20/Box)
$8
222711NPP
2 in. Condensing 90 Degree Elbow (20/Box)
$10
222712NPP
2 in. Condensing Vent Pipe Extension 39 in. (4/Box)
$70
222714NPP
2 in. Condensing Vent Pipe Extension 79 in. (4/Box)
$95
222715NPP
2 in. Condensing Fixing Clip Metal (Qty 10)
$30
184470NPP
2 in. Condensing Flex Termination Kit
$230
222720NPP
2 in. Flex Connector
$24
222721NPP
2 in. Flex Roll (41.5 ft.)
$300
223085NPP
2 in. Condensing Wall Terminal Twin Pipe
$80
187595NPP
2 in. x 2 in. / 4 in. Condensing Twin Pipe Adaptor
$75
710202NPP
2 in. / 4 in. Condensing 90 Degree Diverter Nose
$17
710215NPP
2 in. / 4 in. Condensing 45 Degree Diverter Nose
$12
229011NPP
2 in. / 4 in. Condensing Horizontal Termination Kit 8.7 in.
$75
229012NPP
2 in. / 4 in. Condensing Horizontal Termination Kit 12 in.
$80
229013NPP
2 in. / 4 in. Condensing Horizontal Termination Kit 21 in.
$84
229016NPP
2 in. / 4 in. Condensing 21 in. Wall Term (2 wall plates)
$55
224356NPP
2 in. / 4 in. Condensing Roof Discharge Term 20 in. Above Roof
$80
229205NPP
2 in. / 4 in. Condensing 45 Degree Elbow Qty 2
$45
229230NPP
2 in. / 4 in. (60/100) Condensing 90 Degree Elbow
$32
229253NPP
2 in. / 4 in. Condensing Horizontal Starter Adapter
$35
229308NPP
2 in. / 4 in. Condensing Vent Pipe Extension 10 in.
$29
229309NPP
2 in. / 4 in. Condensing Vent Pipe Extension 19.5 in.
$36
229310NPP
2 in. / 4 in. Condensing Vent Pipe Extension 39 in.
$42
227412NPP
2 in. / 4 in. Condensing Vertical Starter Adapter
$45
185348NPP
2 in. / 4 in. Condensing Roof Term Extension Kit
$63
196005PVC
IPEX 2 in. Concentric Termination 2 x 16
$79
196105PVC
IPEX 2 in. Concentric Termination 2 x 28
$87
196125PVC
IPEX 2 in. Concentric Termination 2 x 40
$96
196984PVC
IPEX PVC Low Profile Termination 2 in.
$27
NOTES: • Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. * “NPP” signifies Polypropylene venting components for use with the NEW Rinnai SENSEI™ Condensing Tankless Water Heaters and M-Series Condensing Gas Boilers. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.
2018 SUGGESTED LIST PRICE (USD) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018
Ubbink Vent Components - Concentric Non-Condensing For concentric venting, non-condensing models. Current water heater models incorporate a condensate collector and do not require an “adapter” vent component. (For models manufactured prior to 2008 a separate condensate collector is available) Plastic vent components consist of an outer plastic vent for the air intake (ø5”) and an inner metal vent for the exhaust gases (Ø3”). Metal vent components consist of metal inner and outer vents. Plastic and metal vent components are completely interchangeable. Refer to the Rinnai installation manual and the Ubbink installation instructions for complete installation details and requirements. PLASTIC VENT COMPONENTS
(Plastic Outer Pipe, Metal Inner Pipe)
Universal Non-Condensing Termination Kit
Part No.: 185342
L”
8.7”
223191
11.5” 21”
Part No.: 184118-S
Termination Only Length “L”
Part Number
223181
11.5”
223183
223182
21”
223184
61.4”
8.8”
39”
Part Number
Part No.: 184119
Roof Discharge Termination 18”
Termination Kit (termination, elbow, rubber wall plates) Length “L”
Roof Discharge Termination 38” (Cold Climate)
Roof Termination Extension Kit
Part No.: 223187 L”
Telescoping Vent Length Part No.: 224054
21”
(21” Non-Condensing Horizontal Termination Diverter Kit)
Rubber Wall Plate
Part No.: 710342 (White) Part No.: 710602 (Black) 45 Degree Elbow Part No.: 224050
Vent Pipe Extension
39”
224053
22.3”
224052
7.4”
19.5”
Effective Length 2.2-12 Inches
4.9”
224051
7.8”
10”
Condensate Collector Part No.: 224069
7.2”
2.3”
Part Number
6.4”
Length “L”
90 Degree Elbow Part No.: 224063
Ø0.78”
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
© 2017 Rinnai Corporation
Ubbink-VA-SP-19
JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com
1/2017
Ubbink Vent Components - Concentric Non-Condensing METAL VENT COMPONENTS
(Plastic Outer Pipe, Metal Inner Pipe)
Universal Termination Kit (Metal)
Roof Termination (Metal)
Part No.: 223188 12”
90 Degree Elbow (Metal)
Part No.: 224255
Rubber Wall Plate
Part No.: 710342 (White) Part No.: 710602 (Black) 21”
12” Universal Horizontal Termination (Metal)
39”
7.8”
8.8”
7.2”
6.4”
L”
Part No.: 224250 Vent Support Bracket Part No.: 224049
Thimble Part No.: 224045
10”
224260
19.5”
224265
39”
224270
Part No.: 224245
Ø0.78” Raised Horizontal Termination Kit “Snorkel”
Roof Flashing
Part No.: 224046
15.75”
*Fits 2x4 or 2x6 Wall Construction
Roof Pitch 8.6” Ø5.0”
Horizontal—Flashing Panel Part No.: 102000012
1/12 to 6/12 6/12 to 12/12 8/12 to 16/12
7.4”
45 Degree Elbow (Metal)
Part Number
4.9”
2.3”
Condensate Collector (Metal) Length “L”
Part No. for Part No. for Shingle Roofs Tile Roofs 189950 189951 189952
50171949 50171961 50171954
Condensate Trap Part No.: 222053
Roof Flashing—Flat Part No.: 146141
NSF Cover Part No.: 224040
Flashing for Metal Roof Part No.: 242141
12.25”
Universal Bug Guard Part No.: 224042
4.15”
Pipe Clamp Part No.: 169044
Kit Includes: 14.2” Vent Extenstion, Qty 3-90° Elbow, 19.5” Vent pipe extension, Special wall terminal, Cover.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
(PPs) - Polypropylene Ø3/5 (80/125) Ubbink Vent Components • For use on Rinnai CONDENSING water heaters only.
• Material of Outer/Combustion Air - Plastic.
• Do not combine the vent components illustrated on this page with any other vent components.
• Vent components consist of an outer plastic vent for air intake Ø5 in. (80 mm) and an inner polypropylene vent for the exhaust gases Ø3 in. (125 mm).
• Material of Inner/Exhaust - Polypropylene, Flame Retardant (ULC S636 Gas Vent-BH Class IIC 110°C/230°F)
Refer to the Rinnai Water Heater Installation and Operation manual for complete installation details and requirements. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
(PPs) POLYPROPYLENE VENT COMPONENTS
8.7” (221 mm)
223174PP
12” (305 mm)
223176PP
21” (533 mm)
223177PP
3/5 (80/125) Condensing Horizontal Termination Diverter Kit 19” (483 mm) Part #: 223186PP
3/5 (80/125) Condensing Vent Pipe Extension
L” 3/5 (80/125) Rubber Wall Plate Part No.: 710342(White) Part No.: 710602 (Black)
8.8” (223.5 mm)
3/5 (80/125) Thimble Part #: 224045
*Fits 2x4 or 2x6 Wall Construction
Part Number
10” (254 mm)
224087PP
19.5” (241 mm)
224079PP
39” (991 mm)
224080PP
Kit Includes: • 14.2” (361mm) Vent Extension (Qty. 3) • 90° Elbow • 19.5” (495mm) Vent Pipe Extension • Special wall terminal • Cover
3/5 (80/125) Condensing 45 Degree Elbow (Qty. 2) Part #: 224077PP
2” (53 mm)
3/5 (80/125) Vent Support Bracket Part #: 224049
Roof Flashing Assembly- Flat* Part #: 146141
Roof Flashing*
3/5 (80/125)Condensing 90 Degree Elbow Part #: 224078PP
5.5” (130 mm )
Universal Bug Guard* Part #: 224042
15.75” (400 mm)
8.6” 218 mm
3/5 (80/125) Pipe Clamp Metal Part #: 169043
Length “L”
25” (635 mm)
Part Number
4.7” (119 mm)
3/5 (80/125) Condensing Termination Extension Part #: 185346PP
Maximum Wall thickness “L”
3/5 (80/125) Condensing Roof Discharge Termination 25” (635 mm) above Roof Part #: 184228PP (for 6” B-Vent Flashing)
38” (203.2 mm)
L”
3/5 (80/125) Condensing Raised Horizontal Termination Kit “Snorkel” Part #: 224047PP
5.2” (32 mm)
3/5 (80/125) Condensing Horizontal Termination Kit (termination, elbow, rubber wall plates)
3/5 (80/125) Roof Termination Extension Kit Part #: 185344PP
20.3” (516mm)
38” (965mm)
3/5 (80/125) Condensing Roof Discharge Termination 20” above Roof Part #: 184162PP
Ø5.0” (127 mm)
Pipe Clamp Universal Plastic* Part #: 169044
3/5 (80/125) Horizontal— Flashing Panel Part #: 102000012
12.25” (311 mm)
4.15” (105 mm)
Roof Pitch
Part No. Shingle Roofs
Part No. Tile Roofs
1/12 to 6/12
189950
50171949
6/12 to 12/12
189951
50171961
8/12 to 16/12
189952
50171954
Flashing for Metal Roof* Part #: 242141 *Components are universal for use with 2/4(50/100) and 3/5 (80/125) components.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us © 2017 Rinnai Corporation
Ubbink-PP-SP-07
11/2017
(PPs) - Polypropylene Ø2” UBBINK COMPONENTS For use with the following models: RU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), CU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US). Refer to the Rinnai Water Heater Installation and Operation manual for complete installation details and requirements. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
(PPs) POLYPROPYLENE COMPONENTS 2 in. TWIN PIPE 2 in. (60) Condensing Wall Terminal Twin Pipe Part #: 223085NPP
2 in. TO CONCENTTRIC
2 in. FLEX
2 in. X 2/4 (60/100) Condensing Twin Pipe Adaptor Part #: 187595NPP
NOTE: FLEX VENTING MUST ONLY BE INSTALLED IN CONDENSING, VERTICAL, ROOM AIR APPLICATIONS. 2 in. (60) Condensing Flex Termination Kit Part #: 184470NPP
2/4 (60/100) Condensing Horizontal Termination Kit 21” (533 mm) (termination, rubber wall plates)
2 in. (60) Condensing Vent Pipe Extension
222712NPP
79” (2 m)
222714NPP
21” (533 mm)
2/4 (60/100) Rubber Wall Plate Part #: 710265 (White) Part #: 710192 (Black) 2 in. (60) Flex Roll X 41.5 Ft (12.5 m) Part #: 222721NPP
2 in. (60) Condensing 45 Degree Elbow Part #: 222710NPP
Roof Flashing*
2/4 (60/100) Vent Support Bracket Part #: 224056 15.75” (400 mm)
Ø4.0”(102 mm)
2/4 (60/100) Horizontal— Flashing Panel Part #: 102000022
12.25” (311 mm)
Fixing Clip Metal (Qty. 10) Part #: 222715NPP
38” (965 mm)
Includes: • 4 Vent Pipe Extensions • 4 Fixing Clips
(1) Clip required per vent connection
Pipe Clamp Universal Plastic* Part #: 169044
8.6” (218 mm)
39” (1 m)
Part #: 229016NPP
20.3” (516 mm)
Part Number
6.6” (168 mm)
L”
Length “L”
2/4 (60/100) Condensing Roof Discharge Termination 20” above Roof Part #: 224356NPP
Roof Flashing Assembly- Flat* Part #: 146141
2/4 (60/100) Thimble Part #: 224055
2 in. (60) Condensing 90 Degree Elbow Part #: 222711NPP 2 in. (60) Flex Connector Part #: 222720NPP
2 in. (60) Pipe Clamp Plastic (Qty. 10) Part #: 222716
Roof Pitch
Part No. Shingle Roofs
Part No. Tile Roofs
1/12 to 6/12
189950
50171949
6/12 to 12/12
189951
50171961
8/12 to 16/12
189952
50171954
Flashing for Metal Roof* Part #: 242141
Universal Bug Guard* Part #: 224042
* Components are universal for use with 2/4 (50/100) and 3/5 (80/125) components.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us © 2017 Rinnai Corporation
Ubbink-PP2-SP-00
11/2017
(PPs) - Polypropylene Ø2/4” (60/100) Ubbink Vent Components • For use with the following models: RU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), CU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US). • Do not combine the vent components illustrated on this page with any other vent components.
• Material of Inner/Exhaust - Polypropylene. • Material of Outer/Combustion Air - Plastic. • Vent components consist of an outer plastic vent for air intake Ø4 in. (100 mm) and an inner polypropylene vent for the exhaust gases Ø2 in. (60 mm).
Refer to the Rinnai Water Heater Installation and Operation manual for complete installation details and requirements. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
(PPs) POLYPROPYLENE VENT COMPONENTS 2/4 (60/100) Condensing Horizontal Termination Kit (termination, elbow, rubber wall plates)
2/4 (60/100) Condensing 45 Degree Diverter Nose Part #: 710215NPP
2/4 (60/100) Condensing 90 Degree Diverter Nose Part #: 710202NPP
L”
Part Number
8.7” (221 mm)
229011NPP
12” (305 mm)
229012NPP
21” (533 mm)
229013NPP
2/4 (60/100) Condensing 21 in. Wall Termination (includes 2 wall plates) Part #: 229016NPP
2/4 (60/100) Condensing Horizontal Starter Adapter Part #: 229253NPP
2/4 (60/100) Condensing Vertical Starter Adapter Part #: 227412NPP Ø2/4” (60/100) connection
Ø2/4” (60/100) connection
7.9” (200mm)
19.5” (495mm)
Maximum wall thickness “L”
4.6” (117mm) Ø3/5” (80/125) connection
Fits 2x4 or 2x6 Wall Construction
Length “L”
Part Number
10” (254 mm)
229308NPP
19.5” (240 mm)
229309NPP
39” (991 mm)
229310NPP
2/4 (60/100) Vent Support Bracket Part #: 224056
4.0” (107mm)
Roof Flashing Assembly- Flat* Part #: 146141
Roof Flashing*
2/4 (60/100) Condensing 45 Degree Elbow (Qty. 2) Part #: 229205NPP
2/4 (60/100) Condensing 90 Degree Elbow Part #: 229230NPP
4.9” (124mm)
L”
Ø3/5” (80/125) connection
2.0” (51mm) Universal Bug Guard* Part #: 224042
8.6” (218mm)
2/4 (60/100) Pipe Clamp Metal Part #: 169013
2/4 (60/100) Condensing Vent Pipe Extension
3.35” (85mm)
2/4 (60/100) Rubber Wall Plate Part #: 710265 (White) Part #: 710192 (Black)
6.6” (168mm)
2/4 (60/100) Thimble Part #: 224055
3.3” (84mm)
2/4 (60/100) Condensing Roof Termination Extension Kit Part #: 185348NPP
20.3” (516mm)
38” (965mm)
2/4 (60/100) Condensing Roof Discharge Termination 20” above Roof Part #: 224356NPP
Ø4.0”(102mm) 2/4 (60/100) Horizontal— Flashing Panel Part #: 102000022
12.25” (311mm)
4.15” (105mm)
Pipe Clamp Universal Plastic* Part #: 169044
Roof Pitch
Part No. Shingle Roofs
Part No. Tile Roofs
1/12 to 6/12
189950
50171949
6/12 to 12/12
189951
50171961
8/12 to 16/12
189952
50171954
Flashing for Metal Roof* Part #: 242141 *Components are universal for use with 2/4(60/100) and 3/5 (80-125) components.
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us © 2017 Rinnai Corporation
Ubbink-PP24-SP-00
11/2017