PD
SYSTEM DELOS | SYSTEM DELOS 10
ZUBEHÖR | ACCESSORIES
10
BASE BD
AUSFÜHRUNG Feuerverzinkung gemäß der Norm DIN EN ISO 1461 mit anschließendem Bürsten zur Gewährleistung eines perfekten Oberflächenfinishs. Polyesterpulverlack lackiert.
ERDSTÜCK In-grounding GEWICHT Weight
PD 9
PD 10
D1
1. Segment (Ø x Wandstärke) 1st Section (Ø x thickness)
159x3 mm
159x3 mm
159x3 mm
193x3 mm
193x3 mm
193x3 mm
L1
Länge 1. Segment - 1st Section length
1100 mm
1100 mm
1700 mm
1700 mm
2000 mm
2000 mm 5
D2
2. Segment (Ø x Wandstärke) 2nd Section (Ø x thickness)
102x3 mm
127x3 mm
127x3 mm
127x3 mm
127x3 mm
127x3 mm
L2
Länge 2. Segment - 2nd Section length
3900 mm
2900 mm
2900 mm
3900 mm
3900 mm
4900 mm
D3
3. Segment (Ø x Wandstärke) 3rd Section (Ø x thickness)
-
102x3 mm
102x3 mm
102x3 mm
102x3 mm
102x3 mm
L3
Länge 3. Segment - 3rd Section length
-
1900 mm
2400 mm
2400 mm
2900 mm
2900 mm
D4
Ø Aufsatzstück - Ø Spigot
60x3 mm
60x3 mm
60x3 mm
60x3 mm
60x3 mm
60x3 mm
L4
Länge Ansatzstück - Spigot length
200 mm
200 mm
200 mm
200 mm
200 mm
200 mm
D1
1. Segment - 1st Section
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
D2
2. Segment - 2nd Section
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
D3
3. Segment - 3rd Section
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
D4
Ansatzstück - Spigot
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
A1
Masttür zur Aufnahme eines Kabelübergangskastens - Terminal block hole
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
A2
Kabelzuführungsöffnung - Cable slot
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
T
Erdung - Grounding
H
Höhe über Erde - Luminaire height
5200 mm
6100 mm
7200 mm
8200 mm
9000 mm
10000 mm
H1
Höhe Bedienungstür - Hatch height
800 mm
800 mm
800 mm
1000 mm
1000 mm
1000 mm
H2
Kabeldurchführungsöffnung - Cable slot height
200 mm
200 mm
200 mm
200 mm
200 mm
200 mm
H3
Höhe über Erde intermedio opzionale Middle luminaire installation height (optional)
-
4200 mm
4800 mm
5800 mm
6100 mm
7100 mm
800 mm
800 mm
800 mm
800 mm
1000 mm
1000 mm
53 kg
66 kg
77 kg
93 kg
103 kg
112 kg
P
H L
L4 Ø D3
PD 5 PD 6 PD 7 PD 8 PD 9 PD 10
7
6
Die Wahl des Lichtmastes ist an Statikprüfungen gebunden, die in Abhängigkeit zum Montageort angestellt werden. AEC nimmt die Bemaßung und die Statikprüfung des Lichtmastes gemäß der Norm EN-40 vor.
Bündig zum Mast Flush mounted RESET 18 RESET 18 RESET 18 RESET 0D 18 RESET 0D 18 RESET 0D 18
* Mit 1 oder 2 Sicherungen erhältlich. - Available with 1 or 2 fuses.
6,1
EXTRA GROSSE ÖFFNUNG Maxi terminal block hole
T-39
L
5,2 5
300x85 400x90
HxL
Nach vorhergehender Satikprüfung. Structural verification required. Andere auf Anfrage. Others upon request.
Ø D2
H
GRUNDPLATTE - Plate
L
4
i
L
L2
4
Ø foro - hole Ø
3
3
PD 5 PD 6 PD 7 PD 8 PD 9 PD 10
i
LxL
230 230 230 260 260 260
300x300 300x300 300x300 350x350 350x350 350x350
Ø Loch Wandstärke Hole Ø Thickness 22 15 22 15 22 15 30 20 30 20 30 20
ANKERBOLZENSATZ ANCHOR BOLTS L
Ø
L Ø
PD 5/PD 6 PD 7 500 M 18
PD 8 / PD 9 PD 10 700 M 27
Ausleger - BRACKET
S
A1 L1
Gewindeeinsatz M10, verzinkt - M10 threaded, galvanized insert
Standard Standard T-39 G T-39 G T-39 G T-39 G T-39 G T-39 G
T-39
H
PD 8
BEDIENUNGSTÜR MIT KABELÜBERGANGSKASTEN Terminal block with hatch
8
7,2
H 51 51 51 55 55 55
MPD/C MPD/L 750 1000 S Per composizioni su bracci e bracci sfalsati vedere tabelle pagina 69. For installation on brackets and staggered brackets see tables page 69.
H1
HÖHE Height
PD 7
RESET
T
Querschnitt/Section
Angaben in Millimetern | Measures in millimeters NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)
The pole must be chosen after a structural pole test depending on the area of installation. AEC verifies the dimensioning and the resistance of the column according to the EN-40 standard.
altezze disponibili H altezze disponibili
H2
AUSSTATTUNG Finishing
PD 6
L
8,2
LxL 310x310 310x310 310x310 360x360 360x360 360x360
PD 5 PD 6 PD 7 PD 8 PD 9 PD 10
RESET
6
PD 5
9
Leuchte Höhe available luminaire heights
A2
P
WERKSTOFFE Materials
Colours Code 01, RAL on request.
7
Valori espressi in metri - Valori espressi in metri
ABMESSUNGEN Dimensions
Finish Hot galvanized in accordance with UNI EN ISO 1461, and subsequent brushing to ensure perfect surface finish. Polyester powder coating.
Ø D4
Angaben in Metern | Measures in metres
FARBEN Code 01, RAL auf Anfrage.
Description Circular cross section tapered steel pole with flat steel 9 washer, consisting of two sections (PD 5 version only) or three sections and end spigot, made of tubular elements welded in sequence. The pole is fitted with trims and an ornamental base made of cast iron EN-GJL-200 UNI EN 1561. Cable inlet slot and terminal box slot with finished edges, also suitable for the application of a flush mounted 8 cover door. The poles of the PD range are part of the DELOS system, which includes Delos 1 and Delos 2 lighting bodies, with MPD/C and MPD/L brackets, available in the pole head, or the staggered versions.
L3
BESCHREIBUNG Stahlmast mit rundem, sich verjüngenden Querschnitt mit flacher Unterlegscheibe, bestehend aus zwei Teilen (nur Ausführung PD 5) und drei Teilen, am Ende mit einem Aufsatzstück versehen, aus sequentiell verschweißten Rohrelementen gefertigt. Der Mast ist mit dekorativen Elementen mit Ornamenten ausgestattet, die nach DIN EN 1561 aus Gusseisen EN-GJL-200 gefertigt sind. Erdstück mit Kabelzuführungsöffnung und Masttür zur Aufnahme eines Kabelübergangskastens, Schnittkanten entgratet, bündig zum Mast eingelassene Bedienungstür. Die Masten der Serie PD gehören dem System DELOS an, das die Leuchten Delos 1 und Delos 2 mit den Auslegern MPD/C und MPD/L in der Version als Aufsatzleuchte oder in der versetzt angeordneten Version umfasst.
Ø D1
AEC POLE DIVISION | 67