Design series | Designed by Marzia Bandini - Massimo Sacconi 10

ZUBEHÖR | ACCESSORIES

10

description Steel pole consisting of 2 separate elements. 9 First element: circular tubular cross section consisting of one single section. Second element (upper): circular tubular cross section with bent profile. The top end for the assembly of the upper element has an internal flange system with fastening using 6 stainless 8 steel side screws. The upper element is made of tubular shaped steel, with double differentiated opposite bend. End part with conical steel tip. Standard connection spigot for units with Ø 60 mm connection. Cable inlet slot and terminal box slot with finished edges, also suitable for the application of a flush mounted cover door.

AUSFÜHRUNG Feuerverzinkung gemäß der Norm DIN EN ISO 1461 mit anschließendem Bürsten zur Gewährleistung eines perfekten Oberflächenfinishs. Polyesterpulverlack lackiert.

Finish Hot galvanized in accordance with UNI EN ISO 1461, and subsequent brushing to ensure perfect surface finish. Polyester powder coating.

7

BASE BA/0

H

BESCHREIBUNG Einteilig aus Stahl gefertigter Mast mit rundem Querschnitt, mit einzelnem Ausleger ausgestattet. Für die Montage des Auslegers weist der Kopf ein mit internem Flansch versehenes System auf und ermöglicht eine Befestigung mittels 6 seitlicher Edelstahlschrauben. Der Ausleger ist aus einem Formstahlrohr mit zwei geformten und anschließend verschweißten Teilen gefertigt. Ansatzstück mit Standardstutzen, für Leuchten mit Ø 60 mm und Endstück mit konischer Stahlspitze geeignet. Erdstück mit Kabeldurchführung und Masttür zur Aufnahme eines Kabelübergangskastens, Schnittkanten entgratet, bündig zum Mast eingelassene Bedienungstür.

Ø D3

LP

S

Ø

9

H Ø

RESET

8

RESET

EXTRA GROSSE ÖFFNUNG Maxi terminal block hole L

WERKSTOFFE Materials

D1 D2 A1

AUSSTATTUNG Finishing

A2 T H

HÖHE Height

H1 H2 H3

ERDSTÜCK In-grounding GEWICHT Weight

P

4700 mm

5200 mm

6200 mm

7200 mm

76x3 mm

76x3 mm

76x3 mm

76x3 mm

800 mm

1000 mm

1000 mm

1000 mm

60 mm

60 mm

60 mm

60 mm

850 mm

850 mm

850 mm

850 mm

S235 JR

S235 JR

S235 JR

S235 JR

S235 JR

S235 JR

S235 JR

S235 JR

186x45 mm

186x45 mm

186x45 mm

186x45 mm

186x45 mm

186x45 mm

186x45 mm

186x45 mm

5

5 L L

139x3 mm

i

127x3 mm

H

127x3 mm

H3

127x3 mm

GRUNDPLATTE - Plate

Ø foro - hole Ø

4

PE 6 PE 7 PE 8 PE 9

Gewindeeinsatz M10, verzinkt - M10 threaded, galvanized insert 6000 mm

7000 mm

8000 mm

9000 mm

800 mm

800 mm

1000 mm

1000 mm

200 mm

200 mm

200 mm

200 mm

6780 mm

7740 mm

8740 mm

9740 mm

800 mm

800 mm

800 mm

800 mm

60 kg

75 kg

85 kg

100 kg

Die Wahl des Lichtmastes ist an Statikprüfungen gebunden, die in Abhängigkeit zum Montageort angestellt werden. AEC nimmt die Bemaßung und die Statikprüfung des Lichtmastes gemäß der Norm EN-40 vor.

i

LxL

180 180 260 260

250x250 250x250 350x350 350x350

Ø Loch Wandstärke Hole Ø Thickness 22 15 22 15 30 20 30 20

4

Ø

ANKERBOLZENSATZ ANCHOR BOLTS KIT

L

LP

PE 9

L1

D3

PE 8

3

3

L Ø

PE 6 / PE 7 500 M 18

PE 8 / PE 9 700 M 27

A1

H1

S

PE 7

T

Querschnitt/Section

Angaben in Millimetern | Measures in millimeters NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

The pole must be chosen after a structural pole test depending on the area of installation. AEC verifies the dimensioning and the resistance of the column according to the EN-40 standard.

altezze disponibili H altezze disponibili

H2

D2

PE 6

Leuchte Höhe available luminaire heights

A2

P

ABMESSUNGEN Dimensions

300x85 400x90

HxL

Nach vorhergehender Satikprüfung. Structural verification required. Andere auf Anfrage. Others upon request.

Angaben in Metern | Measures in metres

L1

6

Valori espressi in metri - Valori espressi in metri

D1

1. Segment (Ø x Wandstärke) 1st Section (Ø x thickness) Länge 1. Segment 1st Section length Ø Ausleger Ø Bracket Sporgenza Ausleger Bracket projection Ø Aufsatzstück Ø Spigot Länge Puntale End part length 1. Segment 1st Section Ausleger Bracket Masttür zur Aufnahme eines Kabelübergangskastens Terminal block hole Kabelzuführungsöffnung Cable slot Erdung Grounding Höhe über Erde Luminaire height Höhe Bedienungstür Hatch height Kabeldurchführungsöffnung Cable slot height Höhe über Erde Above ground height

Bündig zum Mast Flush mounted RESET 16 RESET 16 RESET 16 RESET 17

Mit 1 oder 2 Sicherungen erhältlich. - Available with 1 or 2 fuses.

H

Colours Code 01,02,03,04, RAL on request.

FARBEN Code 01,02,03,04, RAL auf Anfrage.

84 300

Standard Standard T-39 G T-39 G T-39 G T-39 G

PE 6 PE 7 PE 8 PE 9

Ø D2

T-39

6

PE 9

BEDIENUNGSTÜR MIT KABELÜBERGANGSKASTEN Terminal block with hatch

T-39

7

PE 6 / PE 7 PE 8 70 250

Ø D1

AEC POLE DIVISION | 87