PE
Design series | Designed by Marzia Bandini - Massimo Sacconi 10
ZUBEHÖR | ACCESSORIES
10
description Steel pole consisting of 2 separate elements. 9 First element: circular tubular cross section consisting of one single section. Second element (upper): circular tubular cross section with bent profile. The top end for the assembly of the upper element has an internal flange system with fastening using 6 stainless 8 steel side screws. The upper element is made of tubular shaped steel, with double differentiated opposite bend. End part with conical steel tip. Standard connection spigot for units with Ø 60 mm connection. Cable inlet slot and terminal box slot with finished edges, also suitable for the application of a flush mounted cover door.
AUSFÜHRUNG Feuerverzinkung gemäß der Norm DIN EN ISO 1461 mit anschließendem Bürsten zur Gewährleistung eines perfekten Oberflächenfinishs. Polyesterpulverlack lackiert.
Finish Hot galvanized in accordance with UNI EN ISO 1461, and subsequent brushing to ensure perfect surface finish. Polyester powder coating.
7
BASE BA/0
H
BESCHREIBUNG Einteilig aus Stahl gefertigter Mast mit rundem Querschnitt, mit einzelnem Ausleger ausgestattet. Für die Montage des Auslegers weist der Kopf ein mit internem Flansch versehenes System auf und ermöglicht eine Befestigung mittels 6 seitlicher Edelstahlschrauben. Der Ausleger ist aus einem Formstahlrohr mit zwei geformten und anschließend verschweißten Teilen gefertigt. Ansatzstück mit Standardstutzen, für Leuchten mit Ø 60 mm und Endstück mit konischer Stahlspitze geeignet. Erdstück mit Kabeldurchführung und Masttür zur Aufnahme eines Kabelübergangskastens, Schnittkanten entgratet, bündig zum Mast eingelassene Bedienungstür.
Ø D3
LP
S
Ø
9
H Ø
RESET
8
RESET
EXTRA GROSSE ÖFFNUNG Maxi terminal block hole L
WERKSTOFFE Materials
D1 D2 A1
AUSSTATTUNG Finishing
A2 T H
HÖHE Height
H1 H2 H3
ERDSTÜCK In-grounding GEWICHT Weight
P
4700 mm
5200 mm
6200 mm
7200 mm
76x3 mm
76x3 mm
76x3 mm
76x3 mm
800 mm
1000 mm
1000 mm
1000 mm
60 mm
60 mm
60 mm
60 mm
850 mm
850 mm
850 mm
850 mm
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
S235 JR
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
186x45 mm
5
5 L L
139x3 mm
i
127x3 mm
H
127x3 mm
H3
127x3 mm
GRUNDPLATTE - Plate
Ø foro - hole Ø
4
PE 6 PE 7 PE 8 PE 9
Gewindeeinsatz M10, verzinkt - M10 threaded, galvanized insert 6000 mm
7000 mm
8000 mm
9000 mm
800 mm
800 mm
1000 mm
1000 mm
200 mm
200 mm
200 mm
200 mm
6780 mm
7740 mm
8740 mm
9740 mm
800 mm
800 mm
800 mm
800 mm
60 kg
75 kg
85 kg
100 kg
Die Wahl des Lichtmastes ist an Statikprüfungen gebunden, die in Abhängigkeit zum Montageort angestellt werden. AEC nimmt die Bemaßung und die Statikprüfung des Lichtmastes gemäß der Norm EN-40 vor.
i
LxL
180 180 260 260
250x250 250x250 350x350 350x350
Ø Loch Wandstärke Hole Ø Thickness 22 15 22 15 30 20 30 20
4
Ø
ANKERBOLZENSATZ ANCHOR BOLTS KIT
L
LP
PE 9
L1
D3
PE 8
3
3
L Ø
PE 6 / PE 7 500 M 18
PE 8 / PE 9 700 M 27
A1
H1
S
PE 7
T
Querschnitt/Section
Angaben in Millimetern | Measures in millimeters NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)
The pole must be chosen after a structural pole test depending on the area of installation. AEC verifies the dimensioning and the resistance of the column according to the EN-40 standard.
altezze disponibili H altezze disponibili
H2
D2
PE 6
Leuchte Höhe available luminaire heights
A2
P
ABMESSUNGEN Dimensions
300x85 400x90
HxL
Nach vorhergehender Satikprüfung. Structural verification required. Andere auf Anfrage. Others upon request.
Angaben in Metern | Measures in metres
L1
6
Valori espressi in metri - Valori espressi in metri
D1
1. Segment (Ø x Wandstärke) 1st Section (Ø x thickness) Länge 1. Segment 1st Section length Ø Ausleger Ø Bracket Sporgenza Ausleger Bracket projection Ø Aufsatzstück Ø Spigot Länge Puntale End part length 1. Segment 1st Section Ausleger Bracket Masttür zur Aufnahme eines Kabelübergangskastens Terminal block hole Kabelzuführungsöffnung Cable slot Erdung Grounding Höhe über Erde Luminaire height Höhe Bedienungstür Hatch height Kabeldurchführungsöffnung Cable slot height Höhe über Erde Above ground height
Bündig zum Mast Flush mounted RESET 16 RESET 16 RESET 16 RESET 17
Mit 1 oder 2 Sicherungen erhältlich. - Available with 1 or 2 fuses.
H
Colours Code 01,02,03,04, RAL on request.
FARBEN Code 01,02,03,04, RAL auf Anfrage.
84 300
Standard Standard T-39 G T-39 G T-39 G T-39 G
PE 6 PE 7 PE 8 PE 9
Ø D2
T-39
6
PE 9
BEDIENUNGSTÜR MIT KABELÜBERGANGSKASTEN Terminal block with hatch
T-39
7
PE 6 / PE 7 PE 8 70 250
Ø D1
AEC POLE DIVISION | 87