naomi_digital_x-ray_brochure_2010

Page 1



Contents From CR to DR................................... 02 No.1 Share in DR Market..................... 04 Features............................................... 06 Operation............................................ 08 Optional Items..................................... 10 Specifications....................................... 12 Support / After-Service........................ 13

Densely aligned CCD sensors with our own unique technology


From CR to DR Since Dr. Roentgen discovered the x-ray in 1895, we used films to capture its light. As the market continues to move towards film-less radiology, the technology to detect x-ray has changed from film-base to CR and now to DR system. Densely aligned CCD sensors in NAOMI are now opening a new frontier in digital radiography to make the radiography process more effective and faster.

02


Direct Digital Radiography CCD Imaging Sensor

03


In 2007 the No.1 Share in DR Market

* Researched by Yano Research Institute of Economy

Digital radiography system, NAOMI has honorably achieved the top share in DR market among private clinics in 2007. We are striving everyday to develop products to meet the customers' needs.

04


192 CCD sensors in the digital radiography system, NAOMI

Direct Digital Radiography CCD Imaging Sensor

05


Features 48 Megapixel High Image Quality NAOMI uses the maximum of 192 monochrome CCD sensors. By aligning them densely with our unique technology, NAOMI has achieved to capture the intense concentration of light and generates 48 megapixel image quality. The newly developed high-performance engine displays the image smoothly in 4096 gray scales (12 bit). A single image contains immense data information to be displayed, from soft tissue to osseous part in smoother and deeper levels of contrast.

Carbon Plate

Scintillator High Resolution Monochrome CCD Sensor

CCD Board

From 5 seconds - Instant Image Display Since it is a retrofit system, it is not necessary to replace x-ray generators, modify the office or redo in-office wirings. It is not associated with any hassles such as developing films or scanning the imaging plate with CR system. It takes seconds from x-ray exposure to image display. There is no more waiting for doctors and patients. The captured images are automatically stored in the computer for easier management of the patients' records.

06

PC NAOMI

USB cable


Simply Replace the Film Cassette The necessary equipments are only NAOMI sensor and a computer. The setup is to replace the film cassette with NAOMI sensor, and the office x-ray environment becomes digitized immediately. The doctors can continue to use their current x-ray generators.

Cost and Space Savings

Film-based

Since films and chemicals are no longer required, it drastically reduces the running cost of the x-ray. It also liberates the dark room and plumbing system for the extra space in the office.

NAOMI

film

None chemicals maintenance No cassette preparation or film development.

*NAOMI only requires electricity fee

Direct Digital Radiography CCD Imaging Sensor

07


Operation Digital Image Manipulation

As simple as a digital camera

The NAOMI software (DICOM 3.0) provides easier methods to digital image manipulation: from magnification on the area of interest, length and angle measurement, contrast adjustment, negative-positive switchover, horizontal/vertical rotation, and side-byside image layout for comparison. It provides more information on a single image to support diagnosis from various angles.

DICOM (Digital Image and Communication in Medicine) A communication standard developed by American College of Radiology (ACR) and National Electrical Manufacturers Association (NEMA) for medical image format acquired from CT, MRI, or digital x-ray.

Smooth Workflow NAOMI X-Ray Generator Through the USB cable, the image data will be downloaded automatically.

ID

USB Cable

Patient

1. Enter the patient information. Create a folder by the chart number or patient name.

08

2. Irradiate The existing x-ray generator in your clinic works with NAOMI.


Side-by-side Layout

Negative/Positive Switchover The image is displayed in both   negative and positive.

It allows to display 2, 4, 9 and 16 images on the screen. 2 images

Negative

4 images

Positive

Annotation

Inversion/Rotation It inverts or rotates the direction of the image. Inversion

Rotation

Another window opens with the image to measure and create an annotation. Length Measurement

Angle Measurement Text Insertion Comment

33.4cm

131.2 o

Create a text box on the image to insert a comment.

The length can be measured directly on the image.

The angle can be measured directly on the image.

PC Through the LAN connection, the different terminals can access and share the captured images.

Exam Room 1

LAN

3. Instant Image Acquisition The captured image is instantly displayed on the monitor and automatically saved into the computer.

Exam Room 2

Operation Room

Manipulating the image is with an easy single click operation on the mouse. A doctor can start diagnosis instantly.

Direct Digital Radiography CCD Imaging Sensor

09



Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.