Simplicity Classic greenhouses instructions

Page 1

Use mm’s only!

A (mm)

B (mm)

6x4

6’3” X 4’3”

1298

6x6

6’3” X 6’4”

1918

6x8

6’3” X 8’4”

1918

2538

6x10 6’3” X 10’4”

3158

6x12 6’3” X 12’5”

3778

Customer Services: Unit 19, Blythe Park, Cresswell, Stoke-on-Trent, ST11 9RD, UK Tel 01782 388811, Fax 01782 388818, email: technical@simplicitygreenhouses.co.uk


Thank you for purchasing your new greenhouse. We recommend you familiarise yourself with the instructions and read all safety information before you commence assembly. These instructions are divided into sections; B-base, partlists,1-sides, 2-front gable, 3-rear, 4-joining the four sides together, 5-roof, 6-vent, 7-door, 8-glazing(8a horticultural glass, 8b toughened glass, 8c polycarbonate glazing when available), 9-vent attachment, 10-door attachment, 11 anchoring down, back cover-packing list. If you need to contact us for assistance please refer to the relevant section/s. Safety Warning  Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when assembling and glazing the building.  Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately.

  

Do not assemble the greenhouse in high winds. For safety reasons and ease of assembly, we recommend that this greenhouse is assembled by a minimum of two people. Please clear all lying snow from the greenhouse roof as it can cause the roof to buckle or collapse.

Site Preparation  When selecting a site for your greenhouse, it is vital that you choose as flat and level an area as possible.

   

A concrete or slabbed base ( slabbed recommended) will provide the most solid foundation for your greenhouse. IMPORTANT: Do not fix your building down until the building is fully assembled, including glazing. Avoid placing your greenhouse under trees or in other vulnerable locations. To minimise the risk of wind damage, try to select as sheltered a site as possible, e.g. beside a hedgerow or garden fence.

Additional Considerations  Please bear in mind that assembling your greenhouse can be time consuming. You may need to spread the construction over two or more days. We recommend that you avoid leaving the building partially glazed. If you ever have to leave your greenhouse half assembled and not anchored down, weigh it down with slabs or bags of sand to stop the wind moving it.  You will find it helpful to prepare a large, clean and clear area in which to work in. A garage floor or flat lawn area is ideal.

  

If you have arranged for someone to install your greenhouse for you, please check that all components are included. Most parts are numbered and can be identified by a stamp or removable label. Alternatively, the components can be identified by lengths detailed in the packing list (see diagram below). Anchoring down your greenhouse should be the final stage of construction just after glazing. Once installed, your greenhouse requires little maintenance, but to maintain the smooth running of your door WD40 or similar can be applied to the door wheels and lower door guides.

Guarantee  Your new greenhouse is guaranteed for 10 years against faulty manufacture of the framework. This does not include glazing, moving parts, accidental damage or wind damage.

KEY KEY DESCRIPTION SYMBOL LOOK

THINK / CHOOSE?

THIS SECTION RELATES TO ANOTHER (e.g. 1 to 5 or 9 back to 6)

622

mm CORRECT

DO NOT FIX DOWN!

1021 CUT

TIGHTEN

DO NOT WET!

CAN BE MIRRORED


Use mm’s only!

6x4

6’3” X 4’3”

6x6

6’3” X 6’4”

6x8

6’3” X 8’4”

A (mm)

B (mm) 1298 1918

1918

2538

6x10 6’3” X 10’4”

3158

6x12 6’3” X 12’5”

3778

OPTION 1: base on grass

OPTION 2: base on slabs

OPTION 3: base on concrete with drainage holes.

OPTION 4: no base on brick


Page Part Section Size 6x 6x 6x 6x 6x Ref No. / Part (mm) 4 6 8 10 12 SYBOL

M6

M6X11

SYNUT M6

M6

79

93

101 125 135

79

93

101 125 135

1025

3716

1026

3096

1027

2476

1028

1856

1029

1236

1030

3716

1031

3096

1032

2476

1033

1856

1034

1236

2

1006

1316

2

1015

1000

1001

1002

1003

1004

1214

1858

1214

1130

1130

1665

2

Page Part Ref No.

Section / Part

Size 6x 6x 6x 6x 6x (mm) 4 6 8 10 12

1005

1665

2

1006

1316

4

1007

615

2

1008

611

1

1011

1858

1

1012

1841

1

1013

1130

1

1014

1130

1

1040

153

4

85

622

93

636

1016

1130

1035

3716

1036

3096

1037

2476

1038

1856

1039

1236

1

1046

375

-

2 2 2 2 2 2 2 2

2

4

4

4

6

4

8

4

10

1

4

1

2

1

1

2

2

4

6

8

10

1

1

1 1 1 1

2 -

-

4

5


Page Part Ref No.

1021

1022

Section / Part

Size 6x 6x 6x 6x 6x (mm) 4 6 8 10 12

622

543

1

2

1

2

1

2

2

4

Page Part Ref No.

2

4

607

1

1

1

2

2

330

1

1

1

2

2

711

2

2

2

4

4

587

M4

6

6

6

12 12

578

M4

6

6

6

12 12

P3 + 1044

12

2

2

2

4

1017

619

1

1018

619

2

1019

619

1

1020

1605

2

1042

2

wheel

1043

11

2

583

19

8

1041

100 2

571 fluff

3500 1

Size 6x 6x 6x 6x 6x (mm) 4 6 8 10 12

SYCLIP

108 132 156 178 202

SYZCLIP

36

44

52

58

66

9 roll

12 roll

12 roll

15 roll

18 roll

SY1023

Section / Part

5000

FOAM

4

10mm

1009

1260

1

1010

390

1

300

34

1


1034

4’ X2 1029

Part No

mm

Quantity

1006

1316

2

1015

1214

2

1029

1236

2

1034

1236

2

M6

10

M6

10

Part No

mm

Quantity

1006

1316

4

1015

1214

4

6’

1033

1856

2

X2

1028

1856

2

1033

1028

M6

20

M6

20

Part No

mm

Quantity

1006

1316

4

1015

1214

6

8’

1032

2476

2

X2

1027

2476

2

1032

1027

1031

10’ X2 1026

M6

24

M6

24

Part No

mm

Quantity

1006

1316

4

1015

1214

8

1031

3096

2

1026

3096

2

M6

28

M6

28

Part No

mm

Quantity

1006

1316

4

1015

1214

10

12’

1030

3716

2

X2

1025

3716

2

1030

1025

M6

32

M6

32


1015

1006

1015


Part No

mm

Quantity

1000

1858

1

1001

1214

2

1002

1130

1

1003

1130

1

1004

1665

1

1005

1665

1

1006

1316

2

1007

615

2

1008

611

1

18

18

M6

2

1002

1003

1008 INTERNAL VIEW

1007

1007

1004

1005

1006

1006

1001

1001

1000

1002/ 1003

ALL VIEWS INTERNAL 1008

1002

1003

1004/ 1005


1007

1004/ 1005

1002/ 1003

1007

1006 1001

1006

1000

1001

1000

ALL VIEWS INTERNAL


Part No

mm

Quantity

1001

1214

2

1004

1665

1

1005

1665

1

1006

1316

2

1011

1858

1

1012

1841

1

1013

1130

1

1014

1130

1

16

16

M6

2

1013

INTERNAL VIEW

1014

1012

1004

1005

1006

1006

1001

1001

1011

1002/ 1003

ALL VIEWS INTERNAL

1002

1003

1004/ 1005


1012

1004/ 1005

1002/ 1003

1012

1006 1001

1006

1011

1001

1011

ALL VIEWS INTERNAL


8

8

M6

4

M6

4


Packed with OPTIONAL metal base!

18mm

If you have a metal base and you live in a windy location then you should drill and fix the frame to the base using 10mm nuts and bolts. Drill centrally between two vertical glazing bars for neatness (it is not essential to drill every section). Make sure the bolt head does NOT interfere with the line of the glass. Cills should be drilled 18mm from the inside vertical face to avoid the front glass face. Do NOT anchor the structure to the ground until the end!

7mm


4’ 10

Part No

mm

Quantity

85

622

1

1016

1130

2

1039

1236

1

6’ 14

Part No

mm

Quantity

93

636

1

1016

1130

4

1038

1856

1

8’ 18

Part No

mm

Quantity

93

636

1

1016

1130

6

1037

2476

1

1 1

1 1

1016

2 2 2

1016 2 1016


10’ 32

Part No

mm

Quantity

93

636

2

1016

1130

8

1036

3096

1

1046

375

4

12’ 38

Part No

mm

Quantity

93

636

2

1016

1130

10

1035

3715

1

1046

375

5

1046

X2 M4 X 4

’ 85 (4

, 93? only)

85 / 93


Part No

mm

Quantity

1021

622

1

1022

543

2

1023

607

1

M6 10mm X 6 X6 M4 X 2 M4 X 2 X1

1021

600 x 545 1022

1022

1021

600mm

545mm


1023

1023

ALL-WEATHER TRANSPARENT SILICONE NOT SUPPLLIED


Part No

mm

Quantity

1017

619

1

1018

619

2

1019

619

1

1020

1605

2

FLUFF FLUFF 1017

X2

INTERNAL VIEW

X2 1020

X8

X2

1018

1020

3.5 m

FLUFF 1019

3.2 m


1017 FLUFF

1020

1020

1020

1019


E.g.

E.g.


X

V

Z

R

A X

A

S

S

PACKED SEPERATELY WITH GLASS, NOT IN GREENHOUSE BOX. LONG EDGE GOES TO THE INSIDE AND TOWARDS THE SKY.

Z E X

X

R

S

450

X

24 610

S

S

4’

6’

8’

10’ 12’

S

610 X 1210

9

11 13

15

17

R

610 x 1144

3

5

7

8

10

A

610 x 610

3

3

3

4

4

V

600 X 545

1

1

1

2

2

E

610 X 439

1

N

610 X 228

1

610mm

6

A S

S

S

Size (mm)

L

S

A

A

N

S

V

D

Z

234 20 610

A

610 x 610

1

D

610 x 153

1

L

573 x 100

5


Z C

A

A

N

4’

6’

8’

A

610 X 610

24 30 36

42

48

U

610 X 544

4

5

7

8

10

V

600 X 545

1

1

1

2

2

B

610 X 467

1

N

610 X 228

1

U C

U

A

A

A

A

A

A

A

A A

A

A A

A

Size (mm)

V

U

V

A

A

A

A

10’ 12’

Z

B

C

C L

A

A

A

A

A

A

464

C

38 610

D

Z

234 20 610

D

610 x 153

1

L

573 x 100

5


V

Z Or optional capping?

R

N

C

A Size (mm)

4’

6’

8’

10’ 12’

S

610 X 1208

4

6

8

10

12

R

610 x 1142

3

5

7

8

10

A

610 x 608

3

3

3

4

4

V

600 X 545

1

1

1

2

2

N

610 X 226

56

64

32 40 48

765mm

4

L

5

447 18

610

B

610

1883

1659

D

C 1668

1233

610

573 x 100

B

232

1659

S

S

S

S

S

1

610mm

Z

R

A

A B

R

610

1233

610

D

C


85, 93?

85

123

,9

3?

85, 93?

85

,9

3?


1009

1260

2

1

2

1008 1009

1009

1017

1019


1010

390

4

1

4 1009 300

n/a

1

1010


EXTERNAL VIEW ON GRASS / SOIL

EXTERNAL VIEW ON GRASS / SOIL

SAN D

No 10 x 2”

EXTERNAL VIEW

O7mm

SLABS / CONCRETE / INTERNAL VIEW

Please note you will have to drill and screw through your metal base and into your solid foundation at an angle from inside the building. On a 6’ x 8’ building you should anchor the building at 10 points using 10 x 2” rawl plugs and screws (NOT SUPPLIED).

SLABS / CONCRETE / INTERNAL VIEW


mm

622

636

1858

1214

1130

1130

1665

1665

1316

615

611

1260

390

1858

1841

1130

1130

1214

1130

619

619

619

1605

622

543

No

85

93

1000

1001

1002

1003

1004

1005

1006

1007

1008

1009

1010

1011

1012

1013

1014

1015

1016

1017

1018

1019

1020

1021

1022

2

1

2

1

2

1

2

2

1

1

1

1

1

1

1

2

6

2

2

1

1

4

1

1

4’

2

1

2

1

2

1

4

4

1

1

1

1

1

1

1

2

8

2

2

1

1

4

1

1

6’

2

1

2

1

2

1

6

6

1

1

1

1

1

1

1

2

8

2

2

1

1

4

1

1

8’

4

2

2

1

2

1

8

8

1

1

1

1

1

1

1

2

8

2

2

1

1

4

1

2

10’

4

2

2

1

2

1

10

10

1

1

1

1

1

1

1

2

8

2

2

1

1

4

1

2

12’

3096 2476 1856 1236 3716

1031 1032 1033 1034 1035

375

1236

1856

2476

9

1

1

2

2

1

1

4’

12

1

1

2

2

1

1

6’

15

2

4

1

2

2

1

2

10’

18

2

5

1

2

2

1

2

12’

1 smalls pack for correct size of building

12

1

1

2

2

1

1

8’

BOX PACKED BY………………………………………………………………………

1046

1039

1038

1037

3096

3716

1030

1036

1236

1856

2476

3096

3716

607

mm

1029

1028

1027

1026

1025

1024

1023

No


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.