GRENTON ANALOG IN/OUT 0-10 V MUL-046-T-17
IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL
The in/out analog module for assembly in DIN rail expands the possibilities of the system and ensures support for popular communication standardsused in automation: 0-10 V and 1-Wire. • features four inputs and four outputs (0-10 V) • fully configurable – the user can set input sensitivity, range of supported values, value scalar and inertias for input • possible to connect any sensor operating in the 1-Wire standard • possible to connect any sensor or receiver operating in the 0-10 V standard to the system
www.Grenton.com
v. 1.0
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL
CONFIGURATION PARAMETERS OF 0-10 V OUTPUTS CHARACTERISTICS Name
Description
Value
Current output value (0.0 – 10.0 V)
ScaledValue
Current value multiplied by scalar
Scale
Output value scalar
Ramp
Time of output value increment (ms)
MinValue
Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Range: 0.0 – 10.0 V
MaxValue
Maximum value which Value can adopt. Attempting to set a higher value will generate an error. Range: 0.0 – 10.0 V
METHODS Name
Description
SetValue
Sets output value (0.0 – 10.0 V)
SetScaledValue
Sets output value taking into account the scalar
SetScale
Sets scalar value
SetRampTime
Sets increments for output value
SetMinValue
Sets MinValue
SetMaxValue
Sets MaxValue
Hold
Reduces or increases the output value using a ramp specified in the parameter. If the ramp parameter is not specified, the default ramp is used
Switch
Switches output state to an opposite state. If time > 0, after a specified period it restores the previous state. The second parameter (ramp) is optional
SwitchOn
Sets output value to MaxValue (default 10.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional
SwitchOff
Sets output value to MinValue (default 0.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional
EVENTS Name
Description
OnChangeValue
Event from changing the output value (when SetValue is requested)
OnLowerValue
Event occurring when the set value is lower than the previous value
OnRiseValue
Event occurring when the set value is higher than the previous value
OnOutRange
Event occurring with an attempt to exceed the permissible range (MinValue .. MaxValue). (The set value is cut down to this range)
OnSwitchOn
Event occuring when MaxValue (default 10.0 V) is set at output
OnSwitchOff
Event occuring when MinValue (default 0.0 V) is set at output
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL
CONFIGURATION PARAMETERS OF 0-10 V INPUTS CHARACTERISTICS Name
Description
Value
Current output value taking into account the scalar
Value%
Current percentage input value of the maximum value (MaxValue characteristic)
Scale
Input scalar – parameter which is used for multiplying the input value during reading
Sensitivity
Sensitivity – minimum change of input state when the OnChangeValue, OnLowerValue or OnRiseValue event is generated
Inertia
Input inertia value
MinValue
Minimum value of the Value characteristic after exceeding which the OnOutRange event is generate
MaxValue
Maximum value of the Value characteristic after exceeding which the OnOutRange event is generate
METHODS Name
Description
SetScale
Sets scalar value (float)
SetSensitivity
Sets input sensitivity value
SetInertia
Sets input inertia value
SetMin
Sets MinValue
SetMax
Sets MaxValue
EVENTS Name
Description
OnChangeValue
Event resulting from changing input state
OnLowerValue
Event occurs when a value lower than the value from the last reading appears at input
OnRiseValue
Event occurs when a value higher than the value from the last reading appears at input
OnOutRange
Event resulting from exceeding the permissible range (MinValue .. MaxValue)
OnSwitchOn
Event occurs when the input value reaches MaxValue
OnSwitchOff
Event occurs when the input value reaches MinValue
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL
CONFIGURATION PARAMETERS OF 1-WIRE SENSORS CHARACTERISTICS Name
Description
Value
Input value
Threshold
Hysteresis size (accuracy 0.1˚C or 0.1%) specifying the sensitivity with which the following events are generated: OnChange, OnLower, OnRise
Sensitivity
Time (in ms) for which the sampled values are averaged
MinValue
Minimum value of the Value characteristic after exceeding which the OnOutRange event is generated
MaxValue
Maximum value of the Value characteristic after exceeding which the OnOutRange event is generated
EVENTS Name
Description
OnChange
Event resulting from changing input state
OnRise
Event resulting from exceeding the upper threshold of hysteresis
OnLower
Event resulting from exceeding the lower threshold of hysteresis
OnOutOfRange
Event resulting from exceeding any range (MinValue .. MaxValue)
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
8.39 mA
weight
90 g
dimensions (H/W/D)
58/71/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
4
operating temperature range
O to +40°C
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL
WIRING DIAGRAM
1...16
1W
TF-Bus
GND
Reciver 0-10 V
DQ
Sensor 0-10 V
DS1820, DS18B20, etc.
VDD
UTP cable, max. 50 m
GND
TF-Bus
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V MUL-067-T-17
IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY
The in/out analogue module for flush- mount assembly expands the possibilities of the system and ensures support for popular communication standards used in automation: 0-10 V and 1-Wire. • features two inputs and two outputs (0-10 V) • fully configurable – the user can set input sensitivity, range of supported values, value scalar and inertias for input • it is possible to connect any sensor operating in the 1-Wire standard • it is possible to connect any sensor or receiver operating in the 0-10 V standard to the system
www.Grenton.com
v. 1.0
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS OF 0-10 V OUTPUTS CHARACTERISTICS Name
Description
Value
Current output value (0.0 – 10.0 V)
ScaledValue
Current value multiplied by scalar
Scale
Output value scalar
Ramp
Time of output value increment (ms)
MinValue
Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Range: 0.0 – 10.0 V
MaxValue
Maximum value which Value can adopt. Attempting to set a higher value will generate an error. Range: 0.0 – 10.0 V
METHODS Name
Description
SetValue
Sets output value (0.0 – 10.0 V)
SetScaledValue
Sets output value taking into account the scalar
SetScale
Sets scalar value
SetRamp
Sets increments for output value
SetMinValue
Sets MinValue
SetMaxValue
Sets MaxValue
Hold
Reduces or increases the output value using a ramp specified in the parameter. If the ramp parameter is not specified, the default ramp is used
Switch
Switches output state to an opposite state. If time > 0, after a specified period it restores the previous state. The second parameter (ramp) is optional
SwitchOn
Sets output value to MaxValue (default 10.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional
SwitchOff
Sets output value to MinValue (default 0.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional
EVENTS Name
Description
OnChangeValue
Event from changing output value (when SetValue is requested)
OnLowerValue
Event occurring when the set value is lower than the previous value
OnRiseValue
Event occurring when the set value is higher than the previous value
OnOutRange
Event occurring with an attempt to exceed the permissible range (MinValue - MaxValue). (The set value is cut down to this range)
OnSwitchOn
Event occuring when MaxValue (default 10.0 V) is set at output
OnSwitchOff
Event occuring when MinValue (default 0.0 V) is set at output
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS OF 0-10 V INPUTS CHARACTERISTICS Name
Description
Value
Current input value taking into account the scalar
Value%
Current percentage input value of the maximum value (MaxValue characteristic)
Scale
Input scalar – parameter which is used for multiplying the input value during reading
Sensitivity
Sensitivity – minimum change of input state when the OnChangeValue, OnLowerValue or OnRiseValue event is generated
Inertia
Input inertia value
MinValue
Minimum value of the Value characteristic after exceeding which th OnOutRange event is generated
MaxValue
Maximum value of the Value characteristic after exceeding which the OnOutRange event is generated
METHODS Name
Description
SetScale
Sets scalar value (float)
SetSensitivity
Sets input sensitivity value
SetInertia
Sets input inertia value
SetMinValue
Sets MinValue
SetMaxValue
Sets MaxValue
EVENTS Name
Description
OnChangeValue
Event resulting from changing the input state
OnLowerValue
Event occurs when a value lower than the value from the last reading appears at input
OnRiseValue
Event occurs when a value higher than the value from the last reading appears at input
OnOutRange
Event resulting from exceeding the permissible range (MinValue - MaxValue)
OnSwitchOn
Event occurs when the input value reaches MaxValue
OnSwitchOff
Event occurs when the input value reaches MinValue
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS OF 1-WIRE SENSORS CHARACTERISTICS Name
Description
Value
Input value
Threshold
Hysteresis size (accuracy 0.1°C or 0.1%) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRaise
MinValue
Minimum value of the Value characteristic after exceeding which the OnOutOfRange event is generated
MaxValue
Maximum value of the Value characteristic after exceeding which the OnOutOfRange event is generated
EVENTS Name
Description
OnChange
Event resulting from changing input state
OnRise
Event resulting from exceeding the upper threshold of hysteresis
OnLower
Event resulting from exceeding the lower threshold of hysteresis
OnOutOfRange
Event resulting from exceeding any range
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
8.39 mA
weight
37 g
dimensions (H/W/D)
52/57/21 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
O to +40°C
www.Grenton.com
GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY
WIRING DIAGRAM
TF-Bus
TF-Bus
DS1820,
UTP cable, max. 50 m
1W
GND
Receiver 0-10 V
VDD
Sensor 0-10 V
DQ
DS18B20, etc.
GND
1...16
www.Grenton.com
GRENTON CLU Z-WAVE CLU-022-E-02
COMMON LOGIC UNIT FOR DIN RAIL ASSEMBLY
The Common Logic Unit (CLU) module for DIN rail assembly, with Z-Wave wireless communication controller, executes the function of processing logic and storing the configuration. The CLU constitutes the basis for every system. The CLU module also ensures communication with IOM modules via a local busbar. It expands the communication possibilities of the GRENTON system with a wireless network. • • • • • • • • • • •
stores system configuration completes all calculations enables connection with the system Features a built-in switch and two RJ45 ports allows you to connect 48 modules (or 128 inputs/outputs) to the system busbar executes the functionality of cloud computing (distributed computing) allows you to connect the system to the internet stores created scripts/scenes enables you to create virtual CLU objects (timers, calendars, schedules, PID controllers, etc.) enables you to connect the system to any wireless device operating with the use of Z-Wave features a built-in busbar supply unit with 1000 mA capacity
www.Grenton.pl
v. 1.0
GRENTON CLU Z-WAVE
COMMON LOGIC UNIT FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Uptime
Time of device operation since last reset (in seconds)
Log
Internal device log
State
Device state
Date
Current date
Time
Current time (hh:mm:dd)
Day
Number of the current day of the month
Month
Current number of the month
Year
Current number of the year
DayOfWeek
Current day of the week (0 = Sunday)
Hour
Current hour (no minutes or seconds)
Minute
Current number of minutes from last full hour
UnixTime
Current Unix time
FirmwareVersion
Software version
METHODS Name
Description
AddToLog
Adds a new entry to the internal log
ClearLog
Deletes the contents of the internal device log
SetDateTime
Sets date and time
StartDiscovery
Initiates Z-Wave module discovery mode (if time = 0 then only to the first added node)
StopDiscovery
Stops Z-Wave module discovery mode
EVENTS Name
Description
OnInit
Event occurring once during device initialization
www.Grenton.com
GRENTON CLU Z-WAVE
COMMON LOGIC UNIT FOR DIN RAIL ASSEMBLY
TECHNICAL SPECIFICATIONS DC supply
12 - 24 V
average current input
112 mA
max. current input
250 mA
Z-Wave frequency
868 MHz
weight
106 g
dimensions (H/W/D)
58/71/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
4
operating temperature range
0 to +40°C
built-in busbar supply unit
1000 mA
WIRING DIAGRAM DC Power Jack 12 – 24 V 12 – 24 V Switch Ethernet 2 x RJ45
TF-Bus
LEDs
TF-Bus
TF-Bus
RS232 service port
LED – status indication: No supply Green diode blink every 500 ms – system OK Configuration error – system not configured or no communication with IOM module CLU in Z-Wave module discovery mode - green diode blink in 200 ms intervals
CLU in Z-Wave module removal mode - red diode blink in 200 ms intervals Confirmation of adding Z-Wave module - green diode lights constantly for 1 second, then green and red diods blink three times in 200 ms intervals Confirmation of removing Z-Wave module - red and green diodes blink three times in 200 ms intevals, then red diode goes off and green diode blink in 500 ms interval
www.Grenton.com
GRENTON DIGITAL IN INP-018-T-16
DIGITAL INPUT MODULE FOR ASSEMBLY ON DIN RAIL
Digital input module allows you to connect any digital input with the system.
• enables you to connect six independent binary input • enables you to connect two 230 V inputs • inputs are fully configurable • operates in two modes: monostable and bistable • differentiates a click in monostable mode, short press, long press, and button hold
www.Grenton.com
v. 1.0
GRENTON DIGITAL IN
DIGITAL INPUT MODULE FOR ASSEMBLY ON DIN RAIL
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns input mode as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs
StatisticState
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device, Pulse - measurement counted when the input state is high
Load
Multiplier of measured value. For StatisticState: Continous - consumption value per unit time; Pulse - consumption value per one pulse
METHODS Name
Description
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON DIGITAL IN
DIGITAL INPUT MODULE FOR ASSEMBLY ON DIN RAIL
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
4.7 mA
weight
94 g
dimensions (H/W/D)
58/71/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
4
operating temperature range
O to +40°C
WIRING DIAGRAM L N
TF-Bus
~230 V
TF-Bus
www.Grenton.com
GRENTON DIGITAL IN INP-029-T-16
DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
Digital input module allows you to connect any digital input with the system. • enables you to connect four independent binary inputs • enables you to connect two 230 V inputs • inputs are fully configurable • operates in two modes: monostable and bistable • differentiates a click in monostable mode, short press, long press, and button hold • recommended installation in a P80 flush or in a flush with side pocket
www.Grenton.com
v. 1.0
GRENTON DIGITAL IN
DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns input mode as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds, after which when pressing and holding a button, the OnHold event occurs
StatisticState
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device, Pulse - measurement counted when the input state is high
Load
Multiplier of measured value. For StatisticState: Continous - consumption value per unit time; Pulse - consumption value per one pulse
METHODS Name
Description
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON DIGITAL IN
DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
4.7 mA
weight
38 g
dimensions (H/W/D)
52/57/21 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
O to +40°C
WIRING DIAGRAM
TF-Bus
~230 V
TF-Bus
L N
www.Grenton.com
GRENTON DIGITAL IN Z-Wave INP-038-Z-04
WIRELESS DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
Wireless digital input module for flush-mount assembly allows you to connect any input with the system. • enables you to connect four 230 V inputs • inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • each input can carry out up to seven independent functions • each function can request up to four events simultaneously • operates with 230 V supply • communicates with other wireless modules using a mesh network
www.Grenton.com
v. 1.0
GRENTON DIGITAL IN Z-Wave
WIRELESS DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns input mode as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing task
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs
METHODS Name
Description
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON DIGITAL IN Z-Wave
WIRELESS DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS AC supply
230 V
average current input
2 mA
max. current input
3 mA
Z-Wave frequency
868 MHz
weight
27 g
dimensions (H/W/D)
19/45/36 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
O to +40°C
WIRING DIAGRAM
~230 V
L N
www.Grenton.com
GRENTON DIMMER DIM-021-T-01
UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY
Universal dimmer module for DIN rail assembly enables smooth control of the light intensity level. • fully configurable • enables the following functions: dimming, continuous activation, and specific-time activation • controlled increment time • enables you to connect a lighting circuit with a total output of 690 W • enables you to define the maximum and minimum values for the lighting circuit
www.Grenton.com
v. 1.1
GRENTON DIMMER
UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Specifies the current output value (0.0 - 1.0)
RampTime
Delay value when changing illumination (in ms)
MinValue
Minimum value which “Value” can adopt. Attempting to set a lower value will generate an error. Range 0.0 - 1.0
MaxValue
Maximum value which “Value” can adopt. Attempting to set a higher value will generate an error. Range 0.0 - 1.0
StatisticState
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device
Load
Multiplier of measured value. For StatisticState: Continous - consumption value per unit time
METHODS Name
Description
SetValue
Sets output value (0.0 - 1.0)
SetRampTime
Determines the time of output value increment (ms)
SetMinValue
Setting the minimum value which can be adopted by an output. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0
SetMaxValue
Setting the maximum value which can be adopted by an output. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0
Hold
Executes the function of illuminating/dimming
Switch
Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments which is optional. If this parameter is not specified, the default ramp is used
SwitchOn
Sets output value to 1. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.
SwitchOff
Sets output value to 0.0. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.
EVENTS Name
Description
OnChange
Event resulting from changing the output state
OnLowerValue
Event occurring when the set value is lower than the current value
OnRaiseValue
Event occurring when the set value is higher than the current value
OnOutOfRange
Event occurring when setting a value which is higher than the MaxValue or lower than the MinValue
OnSwitchOn
Event occurring when the output value is changed from 0 to a value higher than 0
OnSwitchOff
Event occurring when 0 is set at the output
www.Grenton.com
GRENTON DIMMER
UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
8.39 mA
weight
104 g
dimensions (H/W/D)
58/36/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
2
operating temperature range
O to +40°C
maximum load
690 W
WIRING DIAGRAM ~230 V
L N
Bulb
TF-Bus
TF-Bus
www.Grenton.com
GRENTON DIMMER DIM-031-T-01
UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY
Enables smooth control of the light intensity level. • allows you to connect a lighting circuit with an output of 1x 350 W or 2x 250 W • small size – fits into a P60 box under the ancillary equipment • enables the following functions: dimming,continuous activation, and specific-time activation • controlled increment time • enables you to define the maximum and minimum values for the lighting circuit
www.Grenton.com
v. 1.0
GRENTON DIMMER
UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Specifies the current output value (0.0 - 1.0)
RampTime
Delay value when changing illumination (in ms)
MinValue
Minimum value which Value can adopt. Attempting to set a lower value will generate an error.
MaxValue
Maximum value which Value can adopt. Attempting to set a higher value will generate an error
StatisticState
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device
Load
Multiplier of measured value. For StatisticState: Continous - consumption value per unit time
METHODS Name
Description
SetValue
Sets output value (0.0 - 1.0)
SetRampTime
Determines the time of output value increment (ms)
SetMinValue
Setting the minimum value which can be adopted by an output. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0
SetMaxValue
Setting the maximum value which can be adopted by an output. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0
Hold
Executes the function of illuminating/dimming
Switch
Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used
SwitchOn
Sets output value to 1. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.
SwitchOff
Sets output value to 0. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.
EVENTS Name
Description
OnChange
Event resulting from changing the output state
OnLowerValue
Event occurring when the set value is lower than the current value
OnRaiseValue
Event occurring when the set value is higher than the current value
OnOutOfRange
Event occurring when setting a value which is higher than the MaxValue or lower than the MinValue
OnSwitchOn
Event occurring when the output value is changed from 0 to a value higher than 0
OnSwitchOff
Event occurring when 0 is set at the output
www.Grenton.com
GRENTON DIMMER
UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
8.39 mA
weight
30 g
dimensions (H/W/D)
52/57/21 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
O to +40°C
maximum load
1x 350 W or 2x 250 W
WIRING DIAGRAM
TF-Bus
TF-Bus
Bulb
~230 V
Bulb
L N
www.Grenton.com
GRENTON DIMMER Z-Wave DIM-041-Z-01
WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY
Universal dimmer module enables smooth control of the light intensity level. • allows you to connect a lighting circuit with a total output of 350 W • each of the dimmer responses (dimming, illuminating, activating, etc.) can generate up to 6 events and each event can execute up to 4 functions simultaneously • enables you to define the maximum and minimum values for the lighting circuit • features two 230 V inputs • inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • operates with 230 V supply • communicates with other wireless modules using a mesh network
www.Grenton.com
v. 1.0
GRENTON DIMMER Z-Wave
WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Specifies the current output value (0.0 - 1.0)
RampTime
Delay value when changing illumination (in ms)
MinValue
Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0
MaxValue
Maximum value which Value can adopt. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0
METHODS Name
Description
SetValue
Sets output value (0.0 - 1.0)
SetRampTime
Determines the time of output value increment (ms)
SetMinValue
Setting the minimum value which can be adopted by an output. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0
SetMaxValue
Setting the maximum value which can be adopted by an output. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0
Hold
Executes the function of illuminating/dimming
Switch
SwitchOn
SwitchOff
Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used Sets output value to 1. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) whichis optional. Sets output value to 0. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.
EVENTS Name
Description
OnChange
Event resulting from changing the output state
OnLowerValue
Event occurring when the set value is lower than the current value
OnRaiseValue
Event occurring when the set value is higher than the current value
OnOutOfRange
Event occurring when setting a value which is higher than the MaxValue or lower than the MinValue
OnSwitchOn
Event occurring when the output value is changed from 0 to a value higher than 0
OnSwitchOff
Event occurring when 0 is set at the output
www.Grenton.com
GRENTON DIMMER Z-Wave
WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY
INPUT PROPERTIES CHARACTERISTICS Name
Description
Value
Returns input mode as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs
METHODS Name
Description
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at the input
OnSwitchOff
Occurs when the low state is set at the input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON DIMMER Z-Wave
WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS AC supply
230 V
average current input
2 mA
max current input
3 mA
Z-Wave frequency
868 MHz
weight
37 g
dimensions (H/W/D)
19/45/36
max connection wire section
≤ 1.5 mm2
operating temperature range
O to +40 °C
WIRING DIAGRAM
~230V
L N
www.Grenton.com
~230V
L N
GRENTON GATE ALARM INT-013-E-01
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
Module for integration with external devices and systems. Gate ALARM enables integration with Satel alarm system. • enables the service of up to 60 objects, such as zone, input, output, register • transmits information about the slave systems to the CLU enabling creating complex logic in the Grenton supervisory system • allows to create simple event-based configuration
www.Grenton.com
v. 1.0
GRENTON GATE ALARM
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
UpTime
Time of device operation since last reset (in seconds)
UnixTime
Current Unix time
FirmwareVersion
Gate software version
ClientReportInterval
Characteristics change report period
UpdateTime
Satel state update period
State
Satel state
SatelIP
ETHM Satel module IP address
SatelPort
ETHM Satel module port
AdminPassword
Administrator Satel password
EncryptionEnabled
Encrypting
EncryptionKey
Satel encrypting key
Value
Returns 1 for armed zone, high state at the input or On state at the output. Returns 0 for disarmed zone, low state at the input or Off state at the output.
Nr
Parameter defining to which zone, input, and output refers object.
UserPassword
User password. When setting the user password to "_", it will use the administrator password
METHODS Name
Description
SetDataTime
Sets date and time
SetClientReportInterval
Sets the characteristics change report period
SetUpdateTime
Sets the satel state update period
SetSatelIP
Sets the ETHM Satel module IP address
SetSatelPort
Sets the ETHM Satel module port
SetAdminPassword
Sets the administrator password
SetEncryptionEnabled
Enables or disables enrypting
SetEncryptionKey
Sets the Satel encrypting key
ArmZone
Arms the zone
DisarmZonne
Disarms the zone
SetNr
Sets the parameter defining to which zone, input, and output refers object.
SetUserPassword
Sets the user password. When setting the user password to "_", it will use the administrator password.
SwitchOn
Sets output value to 1
SwitchOff
Sets output value to 0
www.Grenton.com
GRENTON GATE ALARM
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
EVENTS Name
Description
OnInit
Event occurring once during device initialization
OnChange
Event occuring when a change in the state takes place (regardless of the value)
OnSwitchOn
Event occuring when On state is set at output or when high state is set at the input
OnSwitchOff
Event occuring when Off state is set at output or when normal state is set at the input
OnArm
Event occuring zone is armed
OnDisarm
Event occuring zone is disarmed
TECHNICAL SPECIFICATION power options
supply DC
12 - 24 V
TF-Bus
5V
max. current input for 12 V
80 mA
max. current input for 24 V
50 mA
weight
80 g
dimensions (H/W/D)
52/57/21 mm
operating temperature range
0 to +45°C
www.Grenton.com
GRENTON GATE ALARM
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
WIRING DIAGRAM GND
12 - 24 VDC
LED diodes
GATE ALARM
TF-Bus *
TF-Bus *
Reset
Ethernet 8P8C **
*) The device can be alternatively powered by means of the TF-Bus connector that provides 5 VDC power supply. However, it is recommended to use external 12 - 24 VDC supplies as it improves the stability of the system. The device works as a TF-Bus relay so it can be easily installed in the middle of other Grenton modules. **) The GATE module communicates with the CLU unit via the Ethernet network/interface (8P8C Ethernet connector, so-called RJ-45). In order for the system to operate correctly the CLU device(s), the GATE ALARM module as well as the ETH interface of the Alarm device have to be connected to the same ethernet network. LED - status indication: No supply
Slave device reports an error
Green diode blinks - system OK
Error or no configuration
www.Grenton.com
GRENTON GATE MODBUS INT-011-E-01
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
Module for integration with external devices and systems. Gate MODBUS enables integrations with every device supporting MODBUS RTU • possibility to control any Modbus-based devices by means of a mobile application • great integration flexibility thanks to the support for simultaneous communication with various devices, which may also use different transmission parameters • reliable ethernet communication with the Grenton CLU unit
www.Grenton.com
v. 1.0
GRENTON GATE MODBUS
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Uptime
Time of device operation since last reset (in seconds)
UnixTime
Current Unix time
FirmwareVersion
Gate software version
ClientReportInterval
Characteristics change report period
DeviceAddress
Modbus slave device address
AccessRights
Mode: Read or Read/Write
RegisterAddress
Supported register address
TransmisionSpeed
Transmission Speed
ValueType
Variable type
BitPosition
Bit position
BitCount
Number of register's bits
RefreshInterval
Refresh interval
ResponseTimeout
Response timeout
Divisor
Divisor
Endianess
Byte order
RegisterType
Modbus register type
ErrorCode
Error code
Value
Read or write value
RegisterValue
Register value
METHODS Name
Description
SetDateTime
Sets date and time
SetClientReportInterval
Sets the characteristics change report period
SetDeviceAddress
Sets modbus slave device address
SetAccessRights
Sets the mode for read or read/write
SetRegisterAddress
Sets the supported register address
SetTransmisionSpeed
Sets the transmission speed
SetValueType
Sets the variable type
SetBitPosition
Sets bit position
www.Grenton.com
GRENTON GATE MODBUS
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
Name
Description
SetBitCount
Sets the number of register's bits
SetRefreshInterval
Sets the refresh interval
SetResponseTimeout
Sets the response timeout
SetDivisor
Sets the divisor
SetEndianess
Sets byte order
SetRegisterType
Sets the modbus register type
SetValue
Sets read or write value
EVENTS Name
Description
OnInit
Event occurring once during device initialization
OnChange
Event occuring when a change in the state takes place (regardless of the value)
OnError
Event occuring when the slave device reports an error
TECHNICAL SPECIFICATION power options
supply DC
12 - 24 V
TF-Bus
5V
max. current input for 12 V
80 mA
max. current input for 24 V
50 mA
weight
80 g
dimensions (H/W/D)
52/57/21 mm
operating temperature range
0 to +45°C
Modbus physical layer
RS-485
www.Grenton.com
GRENTON GATE MODBUS
UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY
WIRING DIAGRAM TERM Modbus termination **
12 - 24 VDC
TERM
ON OFF
LED diodes Modbus B
GND
Modbus A
GATE MODBUS
TF-Bus *
TF-Bus *
Reset
Ethernet 8P8C
*) The device can be alternatively powered by means of the TF-Bus connector that provides 5 VDC power supply. However, it is recommended to use external 12 - 24 VDC supplies as it improves the stability of the system. The device works as a TF-Bus relay so it can be easily installed in the middle of other Grenton modules. **) If the GATE MODBUS is located at a physical end of the bus (Modbus), a terminator jumper should be placed in the ON position. For correct operation of the Modbus, termination is required at both ends.
LED - status indication: No supply
Slave device reports an error
Green diode blinks - system OK
Error or no configuration
www.Grenton.com
GSM
MUL-036-T-06
GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY
Enables bidirectional connection of the user with the system using a mobile telephone network. • sends information and receives requests • “Ask” function – if any events occur, a text message is sent with a request for response • enables you to divert a voice call to a mobile telephone
www.Grenton.com
GSM
GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Inbox
Inbox containing the last text message received. Does not apply to Y/N text messages sent in response to queries made using the Ask() method
Outbox
Outbox containing the outgoing buffer
AccessList
List of numbers which can be used for sending requests, e.g. 555555555; 666666666; A semi-colon must be included at the end!
ScriptList
List of scripts (scenes) which can be requested by text messages. List format: script1;script2;script3; etc. In practice, this will look as follows: waterplants;switchonboiler;switchoffboiler; A semi-colon must be included at the end!
Password
Password which must be included in a text message sent to the address of the gateway (if PassMandatory is set to 1)
PassMandatory
If set to 0, password is not required. If set to 1, password is required
ConfirmMessage
A confirmation text message. If defined, it will be sent after each correct activation of a script whose name was sent via a text message
RefuseMessage
A refusal text message. If defined, it will be sent after each correct activation of a script whose name was sent via a text message
SignalLevel
Mobile network signal level in the range of 0 - 32
AskConfirm
Text specifying the form of a confirmation message for the Ask() method, e.g. “y”, “yes”
AskRefuse
Text specifying the form of a refusal message for the Ask() method, e.g. “n”, “no”
PIN
PIN code of SIM card
METHODS Name
Description
ClearInbox
Clears the incoming buffer (inbox). The incoming buffer is cleared automatically when a new text message is received. This does not apply to text messages with Y/N confirmations.
ClearOutbox
Clears outgoing buffer (outbox)
AddToOutbox
Adds text to outgoing buffer (outbox)
SendOutboxTo
Sends outbox content to the specified number
Ask
A method which sends an enquiry to a telephone number. It returns 1 if the user received the message with a confirmation response and 0 if the response was a refusal or if the user did not respond in the required time (timeout). Parameters: Ask (tel. number; enquiry; timeout in s). At the end of the enquiry, the following text form is always added: [AskConfirm/AskRefuse] so for instance: [Y/N] or [yes/no].
Call
Calls the specified number. The method returns 1 if the connection is established or 0 when there is no connection
Drop
Drops the voice call
www.Grenton.com
GSM
GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY
EVENTS Name
Description
OnReceive
Occurs immediately after receiving a text message.
OnSend
The user can read an Inbox characteristic to check the text message content
OnStatus
Occurs immediately after sending a text message
OnCall
Occurs immediately after receiving a text message with the status command
OnScript
Occurs when a voice call is answered (only AccessList number calls are answered – the remainder are rejected)
TEXT MESSAGE COMMANDS Name
Description
“Help” or “password:Help”
If the number is included on the AccessList (if created) and when the password is correct (if required), it returns a list of the available scripts (ScriptList characteristic)
“Status” or “password:Status”
Generates the OnStatus event
Name of script with or without password
When the user sends the following text message to the number of the gateway: lamp1, the OnScript event will be generated when the following conditions are met: - no password is required; - the number is on the AccessList (AccessList characteristic); - “lamp1” is on the list of available scripts (ScriptList characteristic). If the password is required, the text message should be as follows: “password:lamp1”, so the command must be preceded by the password. A colon, semi-colon, comma, period or slash can be used as the separator (i.e. any non-letter character).
TECHNICAL SPECIFICATIONS DC supply
12 - 48 V
average current input (with 12V)
17 mA
max. current input (with 12V)
1000 mA
weight
72 g
dimensions (H/W/D)
58/36/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
2
operating temperature range
O to +40°C
www.Grenton.com
GSM
GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY
WIRING DIAGRAM 12 - 24 V LEDs
TF-Bus
TF-Bus
LED – status indication: Green diode flashes every 500 ms – no errors in the module, correct reception Red diode flashes every 500 ms – no reception Red diode is illuminated continuously – module not connected Red diode flashes ever 200 ms – no SIM card or card error Green diode flashes every 200 ms, for t = time – the module sent an enquiry with the Ask function and is awaiting response; t = time for awaiting response
www.Grenton.com
GRENTON LED RGB RGB-028-T-01
LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY
Enables smooth and full control of decorative lighting using LED RGB technology. • dimming function – allows it to operateas a three-channel dimmer • full freedom when setting the color: RGB or HSV model • 16.8 million colors • enables you to adjust both the saturation and hue • smooth transition when changing color, saturation, and intensity • enables you to set the ramp (transition time) for transitions between colors, saturation, and intensity of light
www.Grenton.com
v. 1.0
GRENTON LED RGB
LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Brightness value (range: 0 - 1)
Hue
Color hue value as per the HSV model (0 - 360)
Saturation
Color saturation value (0 - 1)
Rvalue
R component value (0 - 255) – Red
Gvalue
G component value (0 - 255) – Green
Bvalue
B component value (0 - 255) – Blue
#RGB
Color value as per the RGB model “#RRGGBB” (specified in HEX)
RampTime
Time value of increment of color and brightness (ms)
MinValue MaxValue
Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Maximum value which Value can adopt. Attempting to set a higher value will generate an error.
Rcorrection
White correction – channel R (0 - 10,000), default 10,000
Gcorrection
White correction – channel G (0 - 10,000), default 8,333
Bcorrection
White correction – channel B (0 - 10,000), default 8,333
METHODS Name
Description
SetValue
Sets output value (0 - 1)
SetHue
Sets hue value (0 - 360)
SetSaturation
Sets saturation value (0 - 1)
SetRvalue
Sets R component value (0 - 255)
SetGvalue
Sets G component value (0 - 255)
SetBvalue
Sets B component value (0 - 255)
Set#RGB
Sets RGB value using the “#RRGGBB” string
HoldValue
Executes illumination/dimming function
HoldHue
Executes smooth hue transition
Switch
Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used.
SwitchOn
Sets output value to MaxValue
SwitchOff
Sets output value to MinValue
SetRampTime
Sets value of increment of color and input (ms)
SetMax
Sets MaxValue
SetMin
Sets MinValue
www.Grenton.com
GRENTON LED RGB
LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY
EVENTS Name
Description
OnChange
Event occurring when changing the output state
OnSwitchOn
Event occurring when the output state is changed from = 0 to >0
OnSwitchOff
Event occurring when “0” is set at the output
OnRaiseValueSet
Event occurring when the set value is higher than the current value
OnLowerValueSet
Event occurring when the set value is lower than the current value
OnOutOfRange
Event occurring when setting a value which is higher than the maximum value or lower than the minimum value
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
8.39 mA
weight
90 g
dimensions (H/W/D)
58/36/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
2
operating temperature range
O to +40°C
maximum load
16 A - total for all channels
www.Grenton.com
GRENTON LED RGB
LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY
WIRING DIAGRAM
COM 12 VDC
12 VDC
LED Red
COM
LED Green LED 3
LED Blue
LED 2 LED 1
TF-Bus
www.Grenton.com
TF-Bus
TF-Bus
TF-Bus
GRENTON LED RGB RGB-042-T-16
LED RGB LIGHTING CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
Enables smooth and full control of decorative lighting using LED RGB technology. • dimming function – allows it to operate as a three-channel dimmer • full freedom when setting the color: RGB or HSV model • 16.8 million colors • enables you to adjust both the saturation and hue • smooth transition when changing color, saturation, and intensity • enables you to set the ramp (transition time) for transitions between colors, saturation, and intensity of light
www.Grenton.com
v. 1.0
GRENTON LED RGB
LED RGB LIGHTING CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Brightness value (range: 0 - 1)
Hue
Color hue value as per the HSV model (0 - 360)
Saturation
Color saturation value (0 - 1)
Rvalue
R component value (0 - 255) - Red
Gvalue
G component value (0 - 255) - Green
Bvalue
B component value (0 - 255) - Blue
#RGB
Color value as per the RGB model “#RRGGBB” (specified in HEX)
RampTime
Time value of increment of color and brightness (ms)
MinValue
Minimum value which Value can adopt. Attempting to set a lower value will generate an error.
MaxValue
Maximum value which Value can adopt. Attempting to set a higher value will generate an error.
Rcorrection
White correction - channel R (0 - 10,000), default 10,000
Gcorrection
White correction - channel G (0 - 10,000), default 8,333
Bcorrection
White correction - channel B (0 - 10,000), default 8,333
METHODS Name
Description
SetValue
Sets output value (0 - 1)
SetHue
Sets hue value (0 - 360)
SetSaturation
Sets saturation value (0 - 1)
SetRvalue
Sets R component value (0 - 255)
SetGvalue
Sets G component value (0 - 255)
SetBvalue
Sets B component value (0 - 255)
Set#RGB
Sets RGB value using the “#RRGGBB” string
HoldValue
Executes illumination/dimming function
HoldHue
Executes smooth hue transition
Switch
Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used
SwitchOn
Sets output value to MaxValue
SwitchOff
Sets output value to MinValue
SetRampTime
Sets value of increment of color and input (ms)
SetMax
Sets MaxValue
SetMin
Sets MinValue
www.Grenton.com
GRENTON LED RGB
LED RGB LIGHTING CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
EVENTS Name
Description
OnChange
Event occurring when changing the output state
OnSwitchOn
Event occurring when the output state is changed from = 0 to >0
OnSwitchOff
Event occurring when “0” is set at the output
OnRaiseValueSet
Event occurring when the set value is higher than the current value
OnLowerValueSet
Event occurring when the set value is lower than the current value
OnOutOfRange
Event occurring when setting a value which is higher than the maximum value or lower than the minimum value
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
4.7 mA
weight
38 g
dimensions (H/W/D)
52/57/21 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
O to +40°C
maximum load
10 A - total for all channels
WIRING DIAGRAM TF-Bus
TF-Bus
TF-Bus
TF-Bus
LED 3
LED Blue
LED 2
LED Green
LED 1
LED Red 12 VDC
COM
COM 12 VDC
www.Grenton.com
GRENTON RELAYx2 REL-019-T-01
RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY
The relay output module allows you to control any electrical device without the need to use additional control relays. • two relay outputs • enables you to connect a direct load up to 3.6 kVA • enables the following functions: switching, continuous activation and specific-time activation • signals output state with a diode
www.Grenton.com
v. 1.0
GRENTON RELAYx2 DIN
RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns 1 for output set at “On” and 0 for output set at “Off”
StatisticState Load
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device Multiplier of measured value. For StatisticState: Continous - consumption value per unit time;
METHODS Name
Description
SetValue
SetValue Sets output value to 1 or 0
Switch
Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)
SwitchOn
Sets output value to 1
SwitchOff
Sets output value to 0
EVENTS Name
Description
OnChange
Occurs when a change in the state takes place (regardless of the value)
OnSwitchOn
Occurs when “On” is set at output
OnSwitchOff
Occurs when “Off” is set at output
TECHNICAL SPECIFICATIONS DC supply
5V
average current input
4.18 mA
max. current input
112 mA
contact arrangement
2x NO
weight
82 g
dimensions (H/W/D)
58/36/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
2
operating temperature range
O to +40°C
maximum load
3,600 VA per channel
www.Grenton.com
GRENTON RELAYx2 DIN
RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY
WIRING DIAGRAM
L
~230 V
N
Receiver
NO
TF-Bus
TF-Bus
www.Grenton.com
GRENTON RELAYx4 REL-020-T-11
RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY
The relay output module allows you to control any electrical device without the need to use additional control relays. • four relay outputs • enables you to connect a direct load up to 3.6 kVA • enables the following functions: switching, continuous activation and specific-time activation • signals output state with a diode
www.Grenton.com
v. 1.0
GRENTON RELAYx4
RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns 1 for output set at “On” and 0 for output set at “Off”
StatisticState Load
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device Multiplier of measured value. For StatisticState: Continous - consumption value per unit time
METHODS Name
Description
SetValue
SetValue Sets output value to 1 or 0
Switch
Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)
SwitchOn
Sets output value to 1
SwitchOff
Sets output value to 0
EVENTS Name
Description
OnChange
Occurs when a change in the state takes place (regardless of the value)
OnSwitchOn
Occurs when “On” is set at output
OnSwitchOff
Occurs when “Off” is set at output
TECHNICAL SPECIFICATIONS DC supply
5V
average current input
4.16 mA
max. current input
220 mA
contact arrangement
4x NO
weight
146 g
dimensions (H/W/D)
58/71/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
4
operating temperature range
O to +40°C
maximum load
3,600 VA per channel
www.Grenton.com
GRENTON RELAYx4
RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY
WIRING DIAGRAM L
~230V
N
Receiver
NO
TF-Bus
TF-Bus
www.Grenton.com
GRENTON RELAYx2 REL-030-T-01
RELAY OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
Allows you to control any electrical device without the need to use additional control relays. • Two relay outputs • Enables you to connect a direct load up to 1.8 kW • Enables the following functions: switching, continuous activation, and specific-time activation
www.Grenton.com
v. 1.0
GRENTON RELAYx2
RELAY OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns 1 for output set at “On” and 0 for output set at “Off”
StatisticState Load
Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device Multiplier of measured value. For StatisticState: Continous - consumption value per unit time
METHODS Name
Description
SetValue
SetValue Sets output value to 1 or 0
Switch
Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)
SwitchOn
Sets output value to 1
SwitchOff
Sets output value to 0
EVENTS Name
Description
OnChange
Occurs when a change in the state takes place (regardless of the value)
OnSwitchOn
Occurs when “On” is set at output
OnSwitchOff
Occurs when “Off” is set at output
TECHNICAL SPECIFICATIONS DC supply
5V
average current input
4.18 mA
max. current input
112 mA
contact arrangement
2x NO
weight
46 g
dimensions (H/W/D)
52/57/21 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
O to +40°C
maximum load
1,800 VA per channel
www.Grenton.com
GRENTON RELAYx2
RELAY OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
WIRING DIAGRAM
TF-Bus
TF-Bus
NO
Receiver
~230V
L N
www.Grenton.com
GRENTON RELAYx2 Z-Wave REL-039-Z-07
WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
Allows you to control any electrical device without the need to use additional control relays. • two 230 V outputs • enables you to connect a direct load up to 1,800 VA • enables the following functions: switching, continuous activation, and specific-time activation • allows you to connect two 230 V inputs • Inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • operates with 230 V supply • communicates with other wireless modules using a mesh network
www.Grenton.com
v. 1.0
GRENTON RELAYx2 Z-Wave
WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
Value
Returns 1 for output set at “On” and 0 for output set at “Off”
METHODS Name
Description
SetValue
SetValue Sets output value to 1 or 0
Switch
Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)
SwitchOn
Sets output value to 1
SwitchOff
Sets output value to 0
EVENTS Name
Description
OnChange
Occurs when a change in the state takes place (regardless of the value)
OnSwitchOn
Occurs when “On” is set at output
OnSwitchOff
Occurs when “Off” is set at output
www.Grenton.com
GRENTON RELAYx2 Z-Wave
WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
INPUT PROPERTIES CHARACTERISTICS Name
Description
Value
Returns input state as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs
METHODS Name
Description
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at the input
OnSwitchOff
Occurs when the low state is set at the input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON RELAYx2 Z-Wave
WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS AC supply
230 V
average current input
2 mA
max. current input
6 mA
Z-Wave frequency
868 HMz
weight
35 g
dimensions (H/W/D)
19/45/36 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
0 to +40°C
maximum load
1,800 VA per channel
WIRING DIAGRAM
Receiver
~230 V
www.Grenton.com
L N
GRENTON SMART PANEL SPS-001-T-01
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY AND HAND GESTURE CONTROL
Replacing traditional wall switches, Smart Panel allows to control not only the light, but also any device in a smart home. The Panel provides information from sensors, system parameters or its functional data. The versatile and intuitive control interface make it easy and quick to control an individual device or a whole home. • smart design matching every interior • four touch buttons, executing up to four independent functions • each button can signal corectness of activation or errors: ShowOK and ShowError • OLED screen • sound signals • proximity sensor and hand gesture control • temperature and light sensors • unlimited functionality - wide programming possibility www.Grenton.com
v. 1.2
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
BUTTONS PARAMETERS CHARACTERISTICS Name
Description
Value
Returns input state as 0 or 1
Mode
Returns the selected mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs
Label
The text that describes the button
IconA
The file name of the icon assigned to the button in monostable and bistable mode in the OFF position. The name preceded by '~' displays the graphic in negative. IconA has priority on the Label feature
IconB
The file name of the icon assigned to the button in bistable mode in the ON position. The name preceded by '~' displays the graphic in negative
METHODS
2
Name
Description
SetMode
Sets mode of button action (0 - monostabilny (monostable), 1 - bistabilny (bistable), 2 - zablokowany (locked)). In locked mode, the diode is illuminated in continous red light
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
ShowError
Causes the red diode on the button to flash for 2 seconds (frequency 500 ms). The green diode on the button is off
ShowOK
Causes the green diose on the button to flash for 2 seconds (frequency 500 ms). The red diode on the button is off
LedSwitchOn
Activates the green diode on the button
LedSwitchOff
Deactivates the green diode on the button
SetLabel
Sets Label value
SetIconA
Sets IconA value
SetIconB
Sets IconB value
www.Grenton.com
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval value
OnClick
Occurs after pressing the button for less than 500 ms
PANEL PARAMETERS CHARACTERISTICS Name
Description
GestureIconUp
The BMP file name of the icon for gesture Up (without extension)
GestureIconDown
The BMP file name of the icon for gesture Down (without extension)
GestureIconLeft
The BMP file name of the icon for gesture Left (without extension)
GestureIconRight
The BMP file name of the icon for gesture Right (without extension)
ProximitySens
Sensitivity of the proximity sensor
ProximityTimeout
The time after which the display will be blanked
ProximityValue
Proximity sensor value
BuzzerValue
Sound indication control (ON/OFF)
VibraValue
Vibration control (ON/OFF)
www.Grenton.com
3
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
METHODS Name
Description
SwitchOnDisplay
Wakes the display from sleep mode
ShowButtons
Changes display mode into "buttons". Clears the display and shows the icons (or text) for every button
ClearScreen
Clears the display in "freedraw" mode
PrintText
Displays the text in "freedraw" mode
PrintFloat
Displays the float number in "freedraw" mode
DrawLine
Draws the line in "freedraw" mode
DrawPoint
Draws the point in "freedraw" mode
DrawIcon
Draws the icon (bmp) in "freedraw" mode
DisplayContent
Displays the memory graphic buffer content. Changes display mode to "freedraw"
SetGestureIconUp
Sets the icon for gesture Up
SetGestureIconDown
Sets the icon for gesture Down
SetGestureIconLeft
Sets the icon for gesture Left
SetGestureIconRight
Sets the icon for gesture Right
SetProximitySens
Sets the ProximitySens value
SetProximityTimeout
Sets the ProximityTimeout value (in seconds)
SetBuzzerValue
Sets the BuzzerValue
SetVibraValue
Sets the VibraValue
EVENTS Name
Description
OnGestureUp
Occurs after gesture Up
OnGestureDown
Occurs after gesture Down
OnGestureLeft
Occurs after gesture Left
OnGestureRight
Occurs after gesture Right
OnProximityDetect
Occurs when the panel detects the object
GESTURES
Gesture Up
4
www.Grenton.com
Gesture Down
Gesture Left
Gesture Right
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
PREINSTALLED PICTOGRAMS
aircold
airwarm
airwmcd
alarmgo
alarmset
alarm
arrdown
arrup
automat
back
brekfast
brektime
chektime
cold
concierg
dontdist
doorbel
drink1
drink2
economic
elevato1
elevato2
fan1
fan2
fire
gym
heatoff
heaton
lamp1off
lamp1on
lamp2off
lamp2on
lamp3off
lamp3on
laundry
locked
luggtrol
minus
music
next
onoff
play
plus
presence
previous
safe
sauna
sauna2
sday
sdefault
servlea
shclosed
shgroup
shopen
sleep
smood
smovie
snight
socket
sparty
www.Grenton.com
5
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
stoppaus
sun
taxi
temp
tempcold
tempwarm
unlocked
warning
winclose
wingroup
winopen
SENSORES PARAMETERS CHARACTERISTICS Name
Description
Value
Input value: for temperature sensor from 0.0 to 45.0 (°C)
Threshold
Hysteresis size (accuracy 0.1°C) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRise
Sensitivity
Time (in ms) for which the sampled values are averaged
MinValue
Minimum value of the Value characteristic after exceeding which the OnOutOfRange event is generated
MaxValue
Maximum value of the Value characteristic after exceeding which the OnOutOfRange event is generated
EVENTS
6
Name
Description
OnChange
Event resulting from changing input state
OnRaiseValue
Event resulting from exceeding the upper threshold of hysteresis
OnLowerValue
Event resulting from exceeding the lower threshold of hysteresis
OnOutOfRange
Event resulting from exceeding any range
www.Grenton.com
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
TECHNICAL SPECIFICATIONS DC supply
5 - 24V
average current input in a standby mode for 5 V
20 mA
max. current input for 5 V
80 mA
weight
120 g
dimmensions (H/W/D)
surface part: 80/80/10 mm, concealed part: Ø 50 mm / h: 22 mm
operating temperature range
0 - 45°C (without condesantion)
microSD CARD INSTALLATION The card should be installed with the power supply turned off.
1
2
3
4 A B
www.Grenton.com
7
GRENTON SMART PANEL
FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY
WIRING DIAGRAM 1
2
flush box
fastening ring
3
TF-Bus
4
click!
push
8
www.Grenton.com
flush box
GRENTON ROLLER SHUTTER RSH-045-T-06
ROLLER SHUTTER CONTROL MODULE FOR DIN RAIL ASSEMBLY
Allows you to control any roller shutter drive. • equipped with two control contacts (up/down, left/right) • for installation in electrical switch rooms • allows you to control drives with a maximum capacity of 3.6 kVA
www.Grenton.com
v. 1.0
GRENTON ROLLER SHUTTER
ROLLER SHUTTER CONTROL MODULE FOR DIN RAIL ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
M1
State of M1 relay
M2
State of M2 relay
State
Device state. 0 - no movement, 1 - moving downwards, 2 - moving upwards
MaxTime
Default Time parameter value. Maximum movement time
METHODS Name
Description
Up
Roller Shutter Up or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Down
Roller Shutter Down or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Start
Roller Shutter Up if the preceding motion was Down or Roller Shutter Down if the preceding motion was Up. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Stop
Stop if moving
Hold
Hold with direction change
HoldUp
Hold always up
HoldDown
Hold always down
EVENTS Name
Description
OnChange
Occurs when changing the state of any of the outputs
OnUp
Occurs when changing the Stop state to the Up state
OnDown
Occurs when changing the Stop state to the Down state
OnStart
Occurs when Start is requested
OnStop
Occurs when Stop is requested
www.Grenton.com
GRENTON ROLLER SHUTTER
ROLLER SHUTTER CONTROL MODULE FOR DIN RAIL ASSEMBLY
TECHNICAL SPECIFICATIONS DC supply
5V
average current input
4.18 mA
max. current input
112 mA
weight
82 g
dimensions (H/W/D)
58/36/90 mm
max. connection wire section
≤ 2.5 mm2
size [DIN]
2
operating temperature range
O to +40°C
maximum load
3,600 VA
WIRING DIAGRAM L
~230V
N
M
TF-Bus
TF-Bus
www.Grenton.com
GRENTON ROLLER SHUTTER RSH-044-T-02
ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
Allows you to control any roller shutter drive. • equipped with two control contacts (up/down, left/right) • small size – fits into a P60 box under the ancillary equipment • allows you to control drives with a maximum capacity of 1.8 kVA
www.Grenton.com
v. 1.0
GRENTON ROLLER SHUTTER
ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
M1
State of M1 relay
M2
State of M2 relay
State
Device state. 0 - no movement, 1 - moving downwards, 2 - moving upwards
MaxTime
Default Time parameter value. Maximum movement time
METHODS Name
Description
Up
Roller Shutter Up or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Down
Roller Shutter Down or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Start
Roller Shutter Up if the preceding motion was Down or Roller Shutter Down if the preceding motion was Up. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Stop
Stop if moving
Hold
Hold with direction change
HoldUp
Hold always up
HoldDown
Hold always down
EVENTS Name
Description
OnChange
Occurs when changing the state of any of the outputs
OnUp
Occurs when changing the Stop state to the Up state
OnDown
Occurs when changing the Stop state to the Down state
OnStart
Occurs when Start is requested
OnStop
Occurs when Stop is requested
www.Grenton.com
GRENTON ROLLER SHUTTER
ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS DC supply
5V
average current input
4.18 mA
max. current input
112 mA
weight
46 g
dimensions (H/W/D)
52/57/21mm
max. connection wire section
≤ 1.5mm2
operating temperature range
O to +40°C
maximum load
1,800 VA
WIRING DIAGRAM TF-Bus
TF-Bus
M
~230V
L N
www.Grenton.com
GRENTON ROLLER SHUTTER Z-Wave RSH-040-Z-02
WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
Allows you to control any roller shutter drive. • equipped with two control contacts (up/down, left/right) • two 230 V outputs • inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • operates with 230 V supply • ccommunicates with other wireless modules using a mesh network
www.Grenton.com
v. 1.0
GRENTON ROLLER SHUTTER Z-Wave
WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
CONFIGURATION PARAMETERS CHARACTERISTICS Name
Description
M1
State of M1 relay
M2
State of M2 relay
State
Output state: 0 – stopped, 1 – moving up, 2 – moving down
MaxTime
Default value for the Time parameter, if “0” was entered
METHODS Name
Description
Up
Roller Shutter Up or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Down
Roller Shutter Down or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Start
Roller Shutter Up if the preceding motion was Down or Roller Shutter Down if the preceding motion was Up. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time
Stop
Stop if moving
Hold
Hold with direction change
HoldUp
Hold always up
HoldDown
Hold always down
EVENTS Name
Description
OnChange
Occurs when changing the state of any of the outputs
OnUp
Occurs when changing the Stop state to the Up state
OnDown
Occurs when changing the Stop state to the Down state
OnStart
Occurs when Start is requested
OnStop
Occurs when Stop is requested
www.Grenton.com
GRENTON ROLLER SHUTTER Z-Wave
WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
INPUT PROPERTIES CHARACTERISTICS Name
Description
Value
Returns input state as 0 or 1
Inertion
Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs
METHODS Name
Description
SetInertion
Sets Inertion value
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at the input
OnSwitchOff
Occurs when the low state is set at the input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON ROLLER SHUTTER Z-Wave
WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY
TECHNICAL SPECIFICATIONS AC supply
230 V
average current input
2 mA
max. current input
3 mA
Z-Wave frequency
868 MHz
contact arrangement
2x NO
weight
35 g
dimensions (H/W/D)
19/45/36 mm
max. connection wire section
≤ 1.5 mm2
operating temperature range
0 to +40°C
maximum load
1,800 VA
WIRING DIAGRAM
M
~230V
www.Grenton.com
L N
GRENTON TOUCH PANEL TPA-023-T-0X
TOUCH PANEL WITH 4 BUTTONS
The touch panel replaces traditional light switches. • 4 buttons • each button can execute up to four independent functions • features a built-in temperature sensor • each button can signal correctness of activation or errors ShowOK and ShowError • available in dierent colors
www.Grenton.com
v. 1.0
GRENTON TOUCH PANEL TOUCH PANEL WITH 4 BUTTONS
BUTTON PROPERTIES CHARACTERISTICS Name
Description
Value
Returns input state as 0 or 1
Mode
Returns the selected mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs.
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs.
METHODS Name
Description
SetMode
Sets the mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
ShowError
Causes the red diode on the button to flash for 2 seconds (frequency 500 ms). The green diode on the button is off
ShowOK
Causes the green diode on the button to flash for 2 seconds (frequency 500 ms). The red diode on the button is off
LedSwitchOn
Activates the green diode on the button
LedSwitchOff
Deactivates the green diode on the button
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON TOUCH PANEL
TOUCH PANEL WITH 4 BUTTONS
SENSOR PROPERTIES CHARACTERISTICS Name
Description
Value
Input value: for temperature sensor from 0.0 to 6553.5 (°C), for light sensor 0 - 100
Threshold
Hysteresis size (accuracy 0.1°C or 0.1%) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRaise
Sensitivity
Time (in ms) for which the sampled values are averaged
MinValue
Minimum value of the Value characteristic after exceeding which the OnOutRange event is generated
METHODS Name
Description
SetThreshold
Changes hysteresis size
SetSensitivity
Changes sensitiv ity value
SetMinValue
Sets minimum value for the Value characteristic
SetMaxValue
Sets maximum value for the Value c haracteristic
EVENTS Name
Description
OnChange
Event resulting from changing input state
OnRaise
Event resulting from exceeding the upper threshold of hysteresis
OnLower
Event resulting from exceeding the lower threshold of hysteresis
OnOutOfRange
Event resulting from exceeding any range
www.Grenton.com
GRENTON TOUCH PANEL TOUCH PANEL WITH 4 BUTTONS
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input
36.3 mA
weight
200 g
dimensions (H/W/D)
160/80/18 mm
operating temperature range
O to +40°C
WIRING DIAGRAM 1
2
3
click!
TF-Bus
www.Grenton.com
GRENTON TOUCH PANEL TPA-02X-T-0X
TOUCH PANEL WITH 8 BUTTONS
The touch panel replaces traditional light switches. • 8 buttons • each button can execute up to four independent functions • features a built-in temperature sensor • each button can signal correctness of activation or errors Show OK and Show ERROR • available in dierent colors
www.Grenton.com
v. 1.0
GRENTON TOUCH PANEL TOUCH PANEL WITH 8 BUTTONS
BUTTON PROPERTIES CHARACTERISTICS Name
Description
Value
Returns input state as 0 or 1
Mode
Returns the selected mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.
HoldDelay
Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs.
HoldInterval
Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs.
METHODS Name
Description
SetMode
Sets the mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.
SetHoldDelay
Sets HoldDelay value
SetHoldInterval
Sets HoldInterval value
ShowError
Causes the red diode on the button to flash for 2 seconds (frequency 500 ms). The green diode on the button is off
ShowOk
Causes the green diode on the button to flash for 2 seconds (frequency 500 ms). The red diode on the button is off
LedSwitchOn
Activates the green diode on the button
LedSwitchOff
Deactivates the green diode on the button
EVENTS Name
Description
OnChange
Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn
Occurs when the high state is set at input
OnSwitchOff
Occurs when the low state is set at input
OnShortPress
Occurs after pressing the button for 500 - 2000 ms
OnLongPress
Occurs after pressing the button for two seconds
OnHold
Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval value
OnClick
Occurs after pressing the button for less than 500 ms
www.Grenton.com
GRENTON TOUCH PANEL
TOUCH PANEL WITH 8 BUTTONS
SENSOR PROPERTIES CHARACTERISTICS Name
Description
Value
Input value: for temperature sensor from 0.0 to 6553.5 (°C), for light sensor 0 - 100
Threshold
Hysteresis size (accuracy 0.1°C or 0.1%) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRaise
Sensitivity
Time (in ms) for which the sampled values are averaged
MinValue
Minimum value of the Value characteristic after exceeding which the OnOutRange event is generated
METHODS Name
Description
SetThreshold
Changes hysteresis size
SetSensitivity
Changes sensitiv ity value
SetMinValue
Sets minimum value for the Value characteristic
SetMaxValue
Sets maximum value for the Value c haracteristic
EVENTS Name
Description
OnChange
Event resulting from changing input state
OnRaise
Event resulting from exceeding the upper threshold of hysteresis
OnLower
Event resulting from exceeding the lower threshold of hysteresis
OnOutOfRange
Event resulting from exceeding any range
www.Grenton.com
GRENTON TOUCH PANEL TOUCH PANEL WITH 8 BUTTONS
TECHNICAL SPECIFICATIONS DC supply
5V
max. current input [mA]
36.3 mA
weight
200 g
dimensions (H/W/D) [mm]
160/80/18
operating temperature range
0 to +40°C
WIRING DIAGRAM 1
2
3
click!
TF-Bus
www.Grenton.com