Grenton Smart Home Datasheets - EN - 2018.10

Page 1

GRENTON ANALOG IN/OUT 0-10 V MUL-046-T-17

IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL

The in/out analog module for assembly in DIN rail expands the possibilities of the system and ensures support for popular communication standardsused in automation: 0-10 V and 1-Wire. • features four inputs and four outputs (0-10 V) • fully configurable – the user can set input sensitivity, range of supported values, value scalar and inertias for input • possible to connect any sensor operating in the 1-Wire standard • possible to connect any sensor or receiver operating in the 0-10 V standard to the system

www.Grenton.com

v. 1.0


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL

CONFIGURATION PARAMETERS OF 0-10 V OUTPUTS CHARACTERISTICS Name

Description

Value

Current output value (0.0 – 10.0 V)

ScaledValue

Current value multiplied by scalar

Scale

Output value scalar

Ramp

Time of output value increment (ms)

MinValue

Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Range: 0.0 – 10.0 V

MaxValue

Maximum value which Value can adopt. Attempting to set a higher value will generate an error. Range: 0.0 – 10.0 V

METHODS Name

Description

SetValue

Sets output value (0.0 – 10.0 V)

SetScaledValue

Sets output value taking into account the scalar

SetScale

Sets scalar value

SetRampTime

Sets increments for output value

SetMinValue

Sets MinValue

SetMaxValue

Sets MaxValue

Hold

Reduces or increases the output value using a ramp specified in the parameter. If the ramp parameter is not specified, the default ramp is used

Switch

Switches output state to an opposite state. If time > 0, after a specified period it restores the previous state. The second parameter (ramp) is optional

SwitchOn

Sets output value to MaxValue (default 10.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional

SwitchOff

Sets output value to MinValue (default 0.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional

EVENTS Name

Description

OnChangeValue

Event from changing the output value (when SetValue is requested)

OnLowerValue

Event occurring when the set value is lower than the previous value

OnRiseValue

Event occurring when the set value is higher than the previous value

OnOutRange

Event occurring with an attempt to exceed the permissible range (MinValue .. MaxValue). (The set value is cut down to this range)

OnSwitchOn

Event occuring when MaxValue (default 10.0 V) is set at output

OnSwitchOff

Event occuring when MinValue (default 0.0 V) is set at output

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL

CONFIGURATION PARAMETERS OF 0-10 V INPUTS CHARACTERISTICS Name

Description

Value

Current output value taking into account the scalar

Value%

Current percentage input value of the maximum value (MaxValue characteristic)

Scale

Input scalar – parameter which is used for multiplying the input value during reading

Sensitivity

Sensitivity – minimum change of input state when the OnChangeValue, OnLowerValue or OnRiseValue event is generated

Inertia

Input inertia value

MinValue

Minimum value of the Value characteristic after exceeding which the OnOutRange event is generate

MaxValue

Maximum value of the Value characteristic after exceeding which the OnOutRange event is generate

METHODS Name

Description

SetScale

Sets scalar value (float)

SetSensitivity

Sets input sensitivity value

SetInertia

Sets input inertia value

SetMin

Sets MinValue

SetMax

Sets MaxValue

EVENTS Name

Description

OnChangeValue

Event resulting from changing input state

OnLowerValue

Event occurs when a value lower than the value from the last reading appears at input

OnRiseValue

Event occurs when a value higher than the value from the last reading appears at input

OnOutRange

Event resulting from exceeding the permissible range (MinValue .. MaxValue)

OnSwitchOn

Event occurs when the input value reaches MaxValue

OnSwitchOff

Event occurs when the input value reaches MinValue

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL

CONFIGURATION PARAMETERS OF 1-WIRE SENSORS CHARACTERISTICS Name

Description

Value

Input value

Threshold

Hysteresis size (accuracy 0.1˚C or 0.1%) specifying the sensitivity with which the following events are generated: OnChange, OnLower, OnRise

Sensitivity

Time (in ms) for which the sampled values are averaged

MinValue

Minimum value of the Value characteristic after exceeding which the OnOutRange event is generated

MaxValue

Maximum value of the Value characteristic after exceeding which the OnOutRange event is generated

EVENTS Name

Description

OnChange

Event resulting from changing input state

OnRise

Event resulting from exceeding the upper threshold of hysteresis

OnLower

Event resulting from exceeding the lower threshold of hysteresis

OnOutOfRange

Event resulting from exceeding any range (MinValue .. MaxValue)

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

8.39 mA

weight

90 g

dimensions (H/W/D)

58/71/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

4

operating temperature range

O to +40°C

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOG MODULE FOR ASSEMBLY IN DIN RAIL

WIRING DIAGRAM

1...16

1W

TF-Bus

GND

Reciver 0-10 V

DQ

Sensor 0-10 V

DS1820, DS18B20, etc.

VDD

UTP cable, max. 50 m

GND

TF-Bus

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V MUL-067-T-17

IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY

The in/out analogue module for flush- mount assembly expands the possibilities of the system and ensures support for popular communication standards used in automation: 0-10 V and 1-Wire. • features two inputs and two outputs (0-10 V) • fully configurable – the user can set input sensitivity, range of supported values, value scalar and inertias for input • it is possible to connect any sensor operating in the 1-Wire standard • it is possible to connect any sensor or receiver operating in the 0-10 V standard to the system

www.Grenton.com

v. 1.0


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS OF 0-10 V OUTPUTS CHARACTERISTICS Name

Description

Value

Current output value (0.0 – 10.0 V)

ScaledValue

Current value multiplied by scalar

Scale

Output value scalar

Ramp

Time of output value increment (ms)

MinValue

Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Range: 0.0 – 10.0 V

MaxValue

Maximum value which Value can adopt. Attempting to set a higher value will generate an error. Range: 0.0 – 10.0 V

METHODS Name

Description

SetValue

Sets output value (0.0 – 10.0 V)

SetScaledValue

Sets output value taking into account the scalar

SetScale

Sets scalar value

SetRamp

Sets increments for output value

SetMinValue

Sets MinValue

SetMaxValue

Sets MaxValue

Hold

Reduces or increases the output value using a ramp specified in the parameter. If the ramp parameter is not specified, the default ramp is used

Switch

Switches output state to an opposite state. If time > 0, after a specified period it restores the previous state. The second parameter (ramp) is optional

SwitchOn

Sets output value to MaxValue (default 10.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional

SwitchOff

Sets output value to MinValue (default 0.0 V). The first parameter is the time of switching (how long it is to be switched for). The second parameter (ramp) is optional

EVENTS Name

Description

OnChangeValue

Event from changing output value (when SetValue is requested)

OnLowerValue

Event occurring when the set value is lower than the previous value

OnRiseValue

Event occurring when the set value is higher than the previous value

OnOutRange

Event occurring with an attempt to exceed the permissible range (MinValue - MaxValue). (The set value is cut down to this range)

OnSwitchOn

Event occuring when MaxValue (default 10.0 V) is set at output

OnSwitchOff

Event occuring when MinValue (default 0.0 V) is set at output

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS OF 0-10 V INPUTS CHARACTERISTICS Name

Description

Value

Current input value taking into account the scalar

Value%

Current percentage input value of the maximum value (MaxValue characteristic)

Scale

Input scalar – parameter which is used for multiplying the input value during reading

Sensitivity

Sensitivity – minimum change of input state when the OnChangeValue, OnLowerValue or OnRiseValue event is generated

Inertia

Input inertia value

MinValue

Minimum value of the Value characteristic after exceeding which th OnOutRange event is generated

MaxValue

Maximum value of the Value characteristic after exceeding which the OnOutRange event is generated

METHODS Name

Description

SetScale

Sets scalar value (float)

SetSensitivity

Sets input sensitivity value

SetInertia

Sets input inertia value

SetMinValue

Sets MinValue

SetMaxValue

Sets MaxValue

EVENTS Name

Description

OnChangeValue

Event resulting from changing the input state

OnLowerValue

Event occurs when a value lower than the value from the last reading appears at input

OnRiseValue

Event occurs when a value higher than the value from the last reading appears at input

OnOutRange

Event resulting from exceeding the permissible range (MinValue - MaxValue)

OnSwitchOn

Event occurs when the input value reaches MaxValue

OnSwitchOff

Event occurs when the input value reaches MinValue

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS OF 1-WIRE SENSORS CHARACTERISTICS Name

Description

Value

Input value

Threshold

Hysteresis size (accuracy 0.1°C or 0.1%) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRaise

MinValue

Minimum value of the Value characteristic after exceeding which the OnOutOfRange event is generated

MaxValue

Maximum value of the Value characteristic after exceeding which the OnOutOfRange event is generated

EVENTS Name

Description

OnChange

Event resulting from changing input state

OnRise

Event resulting from exceeding the upper threshold of hysteresis

OnLower

Event resulting from exceeding the lower threshold of hysteresis

OnOutOfRange

Event resulting from exceeding any range

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

8.39 mA

weight

37 g

dimensions (H/W/D)

52/57/21 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

O to +40°C

www.Grenton.com


GRENTON ANALOG IN/OUT 0-10 V IN/OUT ANALOGUE MODULE FOR FLUSH-MOUNT ASSEMBLY

WIRING DIAGRAM

TF-Bus

TF-Bus

DS1820,

UTP cable, max. 50 m

1W

GND

Receiver 0-10 V

VDD

Sensor 0-10 V

DQ

DS18B20, etc.

GND

1...16

www.Grenton.com


GRENTON CLU Z-WAVE CLU-022-E-02

COMMON LOGIC UNIT FOR DIN RAIL ASSEMBLY

The Common Logic Unit (CLU) module for DIN rail assembly, with Z-Wave wireless communication controller, executes the function of processing logic and storing the configuration. The CLU constitutes the basis for every system. The CLU module also ensures communication with IOM modules via a local busbar. It expands the communication possibilities of the GRENTON system with a wireless network. • • • • • • • • • • •

stores system configuration completes all calculations enables connection with the system Features a built-in switch and two RJ45 ports allows you to connect 48 modules (or 128 inputs/outputs) to the system busbar executes the functionality of cloud computing (distributed computing) allows you to connect the system to the internet stores created scripts/scenes enables you to create virtual CLU objects (timers, calendars, schedules, PID controllers, etc.) enables you to connect the system to any wireless device operating with the use of Z-Wave features a built-in busbar supply unit with 1000 mA capacity

www.Grenton.pl

v. 1.0


GRENTON CLU Z-WAVE

COMMON LOGIC UNIT FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Uptime

Time of device operation since last reset (in seconds)

Log

Internal device log

State

Device state

Date

Current date

Time

Current time (hh:mm:dd)

Day

Number of the current day of the month

Month

Current number of the month

Year

Current number of the year

DayOfWeek

Current day of the week (0 = Sunday)

Hour

Current hour (no minutes or seconds)

Minute

Current number of minutes from last full hour

UnixTime

Current Unix time

FirmwareVersion

Software version

METHODS Name

Description

AddToLog

Adds a new entry to the internal log

ClearLog

Deletes the contents of the internal device log

SetDateTime

Sets date and time

StartDiscovery

Initiates Z-Wave module discovery mode (if time = 0 then only to the first added node)

StopDiscovery

Stops Z-Wave module discovery mode

EVENTS Name

Description

OnInit

Event occurring once during device initialization

www.Grenton.com


GRENTON CLU Z-WAVE

COMMON LOGIC UNIT FOR DIN RAIL ASSEMBLY

TECHNICAL SPECIFICATIONS DC supply

12 - 24 V

average current input

112 mA

max. current input

250 mA

Z-Wave frequency

868 MHz

weight

106 g

dimensions (H/W/D)

58/71/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

4

operating temperature range

0 to +40°C

built-in busbar supply unit

1000 mA

WIRING DIAGRAM DC Power Jack 12 – 24 V 12 – 24 V Switch Ethernet 2 x RJ45

TF-Bus

LEDs

TF-Bus

TF-Bus

RS232 service port

LED – status indication: No supply Green diode blink every 500 ms – system OK Configuration error – system not configured or no communication with IOM module CLU in Z-Wave module discovery mode - green diode blink in 200 ms intervals

CLU in Z-Wave module removal mode - red diode blink in 200 ms intervals Confirmation of adding Z-Wave module - green diode lights constantly for 1 second, then green and red diods blink three times in 200 ms intervals Confirmation of removing Z-Wave module - red and green diodes blink three times in 200 ms intevals, then red diode goes off and green diode blink in 500 ms interval

www.Grenton.com


GRENTON DIGITAL IN INP-018-T-16

DIGITAL INPUT MODULE FOR ASSEMBLY ON DIN RAIL

Digital input module allows you to connect any digital input with the system.

• enables you to connect six independent binary input • enables you to connect two 230 V inputs • inputs are fully configurable • operates in two modes: monostable and bistable • differentiates a click in monostable mode, short press, long press, and button hold

www.Grenton.com

v. 1.0


GRENTON DIGITAL IN

DIGITAL INPUT MODULE FOR ASSEMBLY ON DIN RAIL

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns input mode as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs

StatisticState

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device, Pulse - measurement counted when the input state is high

Load

Multiplier of measured value. For StatisticState: Continous - consumption value per unit time; Pulse - consumption value per one pulse

METHODS Name

Description

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON DIGITAL IN

DIGITAL INPUT MODULE FOR ASSEMBLY ON DIN RAIL

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

4.7 mA

weight

94 g

dimensions (H/W/D)

58/71/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

4

operating temperature range

O to +40°C

WIRING DIAGRAM L N

TF-Bus

~230 V

TF-Bus

www.Grenton.com


GRENTON DIGITAL IN INP-029-T-16

DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

Digital input module allows you to connect any digital input with the system. • enables you to connect four independent binary inputs • enables you to connect two 230 V inputs • inputs are fully configurable • operates in two modes: monostable and bistable • differentiates a click in monostable mode, short press, long press, and button hold • recommended installation in a P80 flush or in a flush with side pocket

www.Grenton.com

v. 1.0


GRENTON DIGITAL IN

DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns input mode as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds, after which when pressing and holding a button, the OnHold event occurs

StatisticState

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device, Pulse - measurement counted when the input state is high

Load

Multiplier of measured value. For StatisticState: Continous - consumption value per unit time; Pulse - consumption value per one pulse

METHODS Name

Description

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON DIGITAL IN

DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

4.7 mA

weight

38 g

dimensions (H/W/D)

52/57/21 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

O to +40°C

WIRING DIAGRAM

TF-Bus

~230 V

TF-Bus

L N

www.Grenton.com


GRENTON DIGITAL IN Z-Wave INP-038-Z-04

WIRELESS DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

Wireless digital input module for flush-mount assembly allows you to connect any input with the system. • enables you to connect four 230 V inputs • inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • each input can carry out up to seven independent functions • each function can request up to four events simultaneously • operates with 230 V supply • communicates with other wireless modules using a mesh network

www.Grenton.com

v. 1.0


GRENTON DIGITAL IN Z-Wave

WIRELESS DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns input mode as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing task

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs

METHODS Name

Description

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON DIGITAL IN Z-Wave

WIRELESS DIGITAL INPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS AC supply

230 V

average current input

2 mA

max. current input

3 mA

Z-Wave frequency

868 MHz

weight

27 g

dimensions (H/W/D)

19/45/36 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

O to +40°C

WIRING DIAGRAM

~230 V

L N

www.Grenton.com


GRENTON DIMMER DIM-021-T-01

UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY

Universal dimmer module for DIN rail assembly enables smooth control of the light intensity level. • fully configurable • enables the following functions: dimming, continuous activation, and specific-time activation • controlled increment time • enables you to connect a lighting circuit with a total output of 690 W • enables you to define the maximum and minimum values for the lighting circuit

www.Grenton.com

v. 1.1


GRENTON DIMMER

UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Specifies the current output value (0.0 - 1.0)

RampTime

Delay value when changing illumination (in ms)

MinValue

Minimum value which “Value” can adopt. Attempting to set a lower value will generate an error. Range 0.0 - 1.0

MaxValue

Maximum value which “Value” can adopt. Attempting to set a higher value will generate an error. Range 0.0 - 1.0

StatisticState

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device

Load

Multiplier of measured value. For StatisticState: Continous - consumption value per unit time

METHODS Name

Description

SetValue

Sets output value (0.0 - 1.0)

SetRampTime

Determines the time of output value increment (ms)

SetMinValue

Setting the minimum value which can be adopted by an output. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0

SetMaxValue

Setting the maximum value which can be adopted by an output. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0

Hold

Executes the function of illuminating/dimming

Switch

Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments which is optional. If this parameter is not specified, the default ramp is used

SwitchOn

Sets output value to 1. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.

SwitchOff

Sets output value to 0.0. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.

EVENTS Name

Description

OnChange

Event resulting from changing the output state

OnLowerValue

Event occurring when the set value is lower than the current value

OnRaiseValue

Event occurring when the set value is higher than the current value

OnOutOfRange

Event occurring when setting a value which is higher than the MaxValue or lower than the MinValue

OnSwitchOn

Event occurring when the output value is changed from 0 to a value higher than 0

OnSwitchOff

Event occurring when 0 is set at the output

www.Grenton.com


GRENTON DIMMER

UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

8.39 mA

weight

104 g

dimensions (H/W/D)

58/36/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

2

operating temperature range

O to +40°C

maximum load

690 W

WIRING DIAGRAM ~230 V

L N

Bulb

TF-Bus

TF-Bus

www.Grenton.com


GRENTON DIMMER DIM-031-T-01

UNIVERSAL DIMMER MODULE FOR DIN RAIL ASSEMBLY

Enables smooth control of the light intensity level. • allows you to connect a lighting circuit with an output of 1x 350 W or 2x 250 W • small size – fits into a P60 box under the ancillary equipment • enables the following functions: dimming,continuous activation, and specific-time activation • controlled increment time • enables you to define the maximum and minimum values for the lighting circuit

www.Grenton.com

v. 1.0


GRENTON DIMMER

UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Specifies the current output value (0.0 - 1.0)

RampTime

Delay value when changing illumination (in ms)

MinValue

Minimum value which Value can adopt. Attempting to set a lower value will generate an error.

MaxValue

Maximum value which Value can adopt. Attempting to set a higher value will generate an error

StatisticState

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device

Load

Multiplier of measured value. For StatisticState: Continous - consumption value per unit time

METHODS Name

Description

SetValue

Sets output value (0.0 - 1.0)

SetRampTime

Determines the time of output value increment (ms)

SetMinValue

Setting the minimum value which can be adopted by an output. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0

SetMaxValue

Setting the maximum value which can be adopted by an output. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0

Hold

Executes the function of illuminating/dimming

Switch

Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used

SwitchOn

Sets output value to 1. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.

SwitchOff

Sets output value to 0. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.

EVENTS Name

Description

OnChange

Event resulting from changing the output state

OnLowerValue

Event occurring when the set value is lower than the current value

OnRaiseValue

Event occurring when the set value is higher than the current value

OnOutOfRange

Event occurring when setting a value which is higher than the MaxValue or lower than the MinValue

OnSwitchOn

Event occurring when the output value is changed from 0 to a value higher than 0

OnSwitchOff

Event occurring when 0 is set at the output

www.Grenton.com


GRENTON DIMMER

UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

8.39 mA

weight

30 g

dimensions (H/W/D)

52/57/21 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

O to +40°C

maximum load

1x 350 W or 2x 250 W

WIRING DIAGRAM

TF-Bus

TF-Bus

Bulb

~230 V

Bulb

L N

www.Grenton.com


GRENTON DIMMER Z-Wave DIM-041-Z-01

WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY

Universal dimmer module enables smooth control of the light intensity level. • allows you to connect a lighting circuit with a total output of 350 W • each of the dimmer responses (dimming, illuminating, activating, etc.) can generate up to 6 events and each event can execute up to 4 functions simultaneously • enables you to define the maximum and minimum values for the lighting circuit • features two 230 V inputs • inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • operates with 230 V supply • communicates with other wireless modules using a mesh network

www.Grenton.com

v. 1.0


GRENTON DIMMER Z-Wave

WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Specifies the current output value (0.0 - 1.0)

RampTime

Delay value when changing illumination (in ms)

MinValue

Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0

MaxValue

Maximum value which Value can adopt. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0

METHODS Name

Description

SetValue

Sets output value (0.0 - 1.0)

SetRampTime

Determines the time of output value increment (ms)

SetMinValue

Setting the minimum value which can be adopted by an output. Attempting to set a lower value will generate an error. Range: 0.0 - 1.0

SetMaxValue

Setting the maximum value which can be adopted by an output. Attempting to set a higher value will generate an error. Range: 0.0 - 1.0

Hold

Executes the function of illuminating/dimming

Switch

SwitchOn

SwitchOff

Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used Sets output value to 1. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) whichis optional. Sets output value to 0. The first parameter is the time of switching (how long it is to be switched for). The second parameter is the ramp (time of value increments) which is optional.

EVENTS Name

Description

OnChange

Event resulting from changing the output state

OnLowerValue

Event occurring when the set value is lower than the current value

OnRaiseValue

Event occurring when the set value is higher than the current value

OnOutOfRange

Event occurring when setting a value which is higher than the MaxValue or lower than the MinValue

OnSwitchOn

Event occurring when the output value is changed from 0 to a value higher than 0

OnSwitchOff

Event occurring when 0 is set at the output

www.Grenton.com


GRENTON DIMMER Z-Wave

WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY

INPUT PROPERTIES CHARACTERISTICS Name

Description

Value

Returns input mode as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs

METHODS Name

Description

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at the input

OnSwitchOff

Occurs when the low state is set at the input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON DIMMER Z-Wave

WIRELESS UNIVERSAL DIMMER MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS AC supply

230 V

average current input

2 mA

max current input

3 mA

Z-Wave frequency

868 MHz

weight

37 g

dimensions (H/W/D)

19/45/36

max connection wire section

≤ 1.5 mm2

operating temperature range

O to +40 °C

WIRING DIAGRAM

~230V

L N

www.Grenton.com

~230V

L N


GRENTON GATE ALARM INT-013-E-01

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

Module for integration with external devices and systems. Gate ALARM enables integration with Satel alarm system. • enables the service of up to 60 objects, such as zone, input, output, register • transmits information about the slave systems to the CLU enabling creating complex logic in the Grenton supervisory system • allows to create simple event-based configuration

www.Grenton.com

v. 1.0


GRENTON GATE ALARM

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

UpTime

Time of device operation since last reset (in seconds)

UnixTime

Current Unix time

FirmwareVersion

Gate software version

ClientReportInterval

Characteristics change report period

UpdateTime

Satel state update period

State

Satel state

SatelIP

ETHM Satel module IP address

SatelPort

ETHM Satel module port

AdminPassword

Administrator Satel password

EncryptionEnabled

Encrypting

EncryptionKey

Satel encrypting key

Value

Returns 1 for armed zone, high state at the input or On state at the output. Returns 0 for disarmed zone, low state at the input or Off state at the output.

Nr

Parameter defining to which zone, input, and output refers object.

UserPassword

User password. When setting the user password to "_", it will use the administrator password

METHODS Name

Description

SetDataTime

Sets date and time

SetClientReportInterval

Sets the characteristics change report period

SetUpdateTime

Sets the satel state update period

SetSatelIP

Sets the ETHM Satel module IP address

SetSatelPort

Sets the ETHM Satel module port

SetAdminPassword

Sets the administrator password

SetEncryptionEnabled

Enables or disables enrypting

SetEncryptionKey

Sets the Satel encrypting key

ArmZone

Arms the zone

DisarmZonne

Disarms the zone

SetNr

Sets the parameter defining to which zone, input, and output refers object.

SetUserPassword

Sets the user password. When setting the user password to "_", it will use the administrator password.

SwitchOn

Sets output value to 1

SwitchOff

Sets output value to 0

www.Grenton.com


GRENTON GATE ALARM

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

EVENTS Name

Description

OnInit

Event occurring once during device initialization

OnChange

Event occuring when a change in the state takes place (regardless of the value)

OnSwitchOn

Event occuring when On state is set at output or when high state is set at the input

OnSwitchOff

Event occuring when Off state is set at output or when normal state is set at the input

OnArm

Event occuring zone is armed

OnDisarm

Event occuring zone is disarmed

TECHNICAL SPECIFICATION power options

supply DC

12 - 24 V

TF-Bus

5V

max. current input for 12 V

80 mA

max. current input for 24 V

50 mA

weight

80 g

dimensions (H/W/D)

52/57/21 mm

operating temperature range

0 to +45°C

www.Grenton.com


GRENTON GATE ALARM

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

WIRING DIAGRAM GND

12 - 24 VDC

LED diodes

GATE ALARM

TF-Bus *

TF-Bus *

Reset

Ethernet 8P8C **

*) The device can be alternatively powered by means of the TF-Bus connector that provides 5 VDC power supply. However, it is recommended to use external 12 - 24 VDC supplies as it improves the stability of the system. The device works as a TF-Bus relay so it can be easily installed in the middle of other Grenton modules. **) The GATE module communicates with the CLU unit via the Ethernet network/interface (8P8C Ethernet connector, so-called RJ-45). In order for the system to operate correctly the CLU device(s), the GATE ALARM module as well as the ETH interface of the Alarm device have to be connected to the same ethernet network. LED - status indication: No supply

Slave device reports an error

Green diode blinks - system OK

Error or no configuration

www.Grenton.com


GRENTON GATE MODBUS INT-011-E-01

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

Module for integration with external devices and systems. Gate MODBUS enables integrations with every device supporting MODBUS RTU • possibility to control any Modbus-based devices by means of a mobile application • great integration flexibility thanks to the support for simultaneous communication with various devices, which may also use different transmission parameters • reliable ethernet communication with the Grenton CLU unit

www.Grenton.com

v. 1.0


GRENTON GATE MODBUS

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Uptime

Time of device operation since last reset (in seconds)

UnixTime

Current Unix time

FirmwareVersion

Gate software version

ClientReportInterval

Characteristics change report period

DeviceAddress

Modbus slave device address

AccessRights

Mode: Read or Read/Write

RegisterAddress

Supported register address

TransmisionSpeed

Transmission Speed

ValueType

Variable type

BitPosition

Bit position

BitCount

Number of register's bits

RefreshInterval

Refresh interval

ResponseTimeout

Response timeout

Divisor

Divisor

Endianess

Byte order

RegisterType

Modbus register type

ErrorCode

Error code

Value

Read or write value

RegisterValue

Register value

METHODS Name

Description

SetDateTime

Sets date and time

SetClientReportInterval

Sets the characteristics change report period

SetDeviceAddress

Sets modbus slave device address

SetAccessRights

Sets the mode for read or read/write

SetRegisterAddress

Sets the supported register address

SetTransmisionSpeed

Sets the transmission speed

SetValueType

Sets the variable type

SetBitPosition

Sets bit position

www.Grenton.com


GRENTON GATE MODBUS

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

Name

Description

SetBitCount

Sets the number of register's bits

SetRefreshInterval

Sets the refresh interval

SetResponseTimeout

Sets the response timeout

SetDivisor

Sets the divisor

SetEndianess

Sets byte order

SetRegisterType

Sets the modbus register type

SetValue

Sets read or write value

EVENTS Name

Description

OnInit

Event occurring once during device initialization

OnChange

Event occuring when a change in the state takes place (regardless of the value)

OnError

Event occuring when the slave device reports an error

TECHNICAL SPECIFICATION power options

supply DC

12 - 24 V

TF-Bus

5V

max. current input for 12 V

80 mA

max. current input for 24 V

50 mA

weight

80 g

dimensions (H/W/D)

52/57/21 mm

operating temperature range

0 to +45°C

Modbus physical layer

RS-485

www.Grenton.com


GRENTON GATE MODBUS

UNIVERSAL GATE MODULE FOR DIN RAIL ASSEMBLY

WIRING DIAGRAM TERM Modbus termination **

12 - 24 VDC

TERM

ON OFF

LED diodes Modbus B

GND

Modbus A

GATE MODBUS

TF-Bus *

TF-Bus *

Reset

Ethernet 8P8C

*) The device can be alternatively powered by means of the TF-Bus connector that provides 5 VDC power supply. However, it is recommended to use external 12 - 24 VDC supplies as it improves the stability of the system. The device works as a TF-Bus relay so it can be easily installed in the middle of other Grenton modules. **) If the GATE MODBUS is located at a physical end of the bus (Modbus), a terminator jumper should be placed in the ON position. For correct operation of the Modbus, termination is required at both ends.

LED - status indication: No supply

Slave device reports an error

Green diode blinks - system OK

Error or no configuration

www.Grenton.com


GSM

MUL-036-T-06

GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY

Enables bidirectional connection of the user with the system using a mobile telephone network. • sends information and receives requests • “Ask” function – if any events occur, a text message is sent with a request for response • enables you to divert a voice call to a mobile telephone

www.Grenton.com


GSM

GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Inbox

Inbox containing the last text message received. Does not apply to Y/N text messages sent in response to queries made using the Ask() method

Outbox

Outbox containing the outgoing buffer

AccessList

List of numbers which can be used for sending requests, e.g. 555555555; 666666666; A semi-colon must be included at the end!

ScriptList

List of scripts (scenes) which can be requested by text messages. List format: script1;script2;script3; etc. In practice, this will look as follows: waterplants;switchonboiler;switchoffboiler; A semi-colon must be included at the end!

Password

Password which must be included in a text message sent to the address of the gateway (if PassMandatory is set to 1)

PassMandatory

If set to 0, password is not required. If set to 1, password is required

ConfirmMessage

A confirmation text message. If defined, it will be sent after each correct activation of a script whose name was sent via a text message

RefuseMessage

A refusal text message. If defined, it will be sent after each correct activation of a script whose name was sent via a text message

SignalLevel

Mobile network signal level in the range of 0 - 32

AskConfirm

Text specifying the form of a confirmation message for the Ask() method, e.g. “y”, “yes”

AskRefuse

Text specifying the form of a refusal message for the Ask() method, e.g. “n”, “no”

PIN

PIN code of SIM card

METHODS Name

Description

ClearInbox

Clears the incoming buffer (inbox). The incoming buffer is cleared automatically when a new text message is received. This does not apply to text messages with Y/N confirmations.

ClearOutbox

Clears outgoing buffer (outbox)

AddToOutbox

Adds text to outgoing buffer (outbox)

SendOutboxTo

Sends outbox content to the specified number

Ask

A method which sends an enquiry to a telephone number. It returns 1 if the user received the message with a confirmation response and 0 if the response was a refusal or if the user did not respond in the required time (timeout). Parameters: Ask (tel. number; enquiry; timeout in s). At the end of the enquiry, the following text form is always added: [AskConfirm/AskRefuse] so for instance: [Y/N] or [yes/no].

Call

Calls the specified number. The method returns 1 if the connection is established or 0 when there is no connection

Drop

Drops the voice call

www.Grenton.com


GSM

GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY

EVENTS Name

Description

OnReceive

Occurs immediately after receiving a text message.

OnSend

The user can read an Inbox characteristic to check the text message content

OnStatus

Occurs immediately after sending a text message

OnCall

Occurs immediately after receiving a text message with the status command

OnScript

Occurs when a voice call is answered (only AccessList number calls are answered – the remainder are rejected)

TEXT MESSAGE COMMANDS Name

Description

“Help” or “password:Help”

If the number is included on the AccessList (if created) and when the password is correct (if required), it returns a list of the available scripts (ScriptList characteristic)

“Status” or “password:Status”

Generates the OnStatus event

Name of script with or without password

When the user sends the following text message to the number of the gateway: lamp1, the OnScript event will be generated when the following conditions are met: - no password is required; - the number is on the AccessList (AccessList characteristic); - “lamp1” is on the list of available scripts (ScriptList characteristic). If the password is required, the text message should be as follows: “password:lamp1”, so the command must be preceded by the password. A colon, semi-colon, comma, period or slash can be used as the separator (i.e. any non-letter character).

TECHNICAL SPECIFICATIONS DC supply

12 - 48 V

average current input (with 12V)

17 mA

max. current input (with 12V)

1000 mA

weight

72 g

dimensions (H/W/D)

58/36/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

2

operating temperature range

O to +40°C

www.Grenton.com


GSM

GSM COMMUNICATION MODULE FOR DIN RAIL ASSEMBLY

WIRING DIAGRAM 12 - 24 V LEDs

TF-Bus

TF-Bus

LED – status indication: Green diode flashes every 500 ms – no errors in the module, correct reception Red diode flashes every 500 ms – no reception Red diode is illuminated continuously – module not connected Red diode flashes ever 200 ms – no SIM card or card error Green diode flashes every 200 ms, for t = time – the module sent an enquiry with the Ask function and is awaiting response; t = time for awaiting response

www.Grenton.com


GRENTON LED RGB RGB-028-T-01

LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY

Enables smooth and full control of decorative lighting using LED RGB technology. • dimming function – allows it to operateas a three-channel dimmer • full freedom when setting the color: RGB or HSV model • 16.8 million colors • enables you to adjust both the saturation and hue • smooth transition when changing color, saturation, and intensity • enables you to set the ramp (transition time) for transitions between colors, saturation, and intensity of light

www.Grenton.com

v. 1.0


GRENTON LED RGB

LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Brightness value (range: 0 - 1)

Hue

Color hue value as per the HSV model (0 - 360)

Saturation

Color saturation value (0 - 1)

Rvalue

R component value (0 - 255) – Red

Gvalue

G component value (0 - 255) – Green

Bvalue

B component value (0 - 255) – Blue

#RGB

Color value as per the RGB model “#RRGGBB” (specified in HEX)

RampTime

Time value of increment of color and brightness (ms)

MinValue MaxValue

Minimum value which Value can adopt. Attempting to set a lower value will generate an error. Maximum value which Value can adopt. Attempting to set a higher value will generate an error.

Rcorrection

White correction – channel R (0 - 10,000), default 10,000

Gcorrection

White correction – channel G (0 - 10,000), default 8,333

Bcorrection

White correction – channel B (0 - 10,000), default 8,333

METHODS Name

Description

SetValue

Sets output value (0 - 1)

SetHue

Sets hue value (0 - 360)

SetSaturation

Sets saturation value (0 - 1)

SetRvalue

Sets R component value (0 - 255)

SetGvalue

Sets G component value (0 - 255)

SetBvalue

Sets B component value (0 - 255)

Set#RGB

Sets RGB value using the “#RRGGBB” string

HoldValue

Executes illumination/dimming function

HoldHue

Executes smooth hue transition

Switch

Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used.

SwitchOn

Sets output value to MaxValue

SwitchOff

Sets output value to MinValue

SetRampTime

Sets value of increment of color and input (ms)

SetMax

Sets MaxValue

SetMin

Sets MinValue

www.Grenton.com


GRENTON LED RGB

LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY

EVENTS Name

Description

OnChange

Event occurring when changing the output state

OnSwitchOn

Event occurring when the output state is changed from = 0 to >0

OnSwitchOff

Event occurring when “0” is set at the output

OnRaiseValueSet

Event occurring when the set value is higher than the current value

OnLowerValueSet

Event occurring when the set value is lower than the current value

OnOutOfRange

Event occurring when setting a value which is higher than the maximum value or lower than the minimum value

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

8.39 mA

weight

90 g

dimensions (H/W/D)

58/36/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

2

operating temperature range

O to +40°C

maximum load

16 A - total for all channels

www.Grenton.com


GRENTON LED RGB

LED RGB LIGHTING CONTROL MODULE FOR DIN RAIL ASSEMBLY

WIRING DIAGRAM

COM 12 VDC

12 VDC

LED Red

COM

LED Green LED 3

LED Blue

LED 2 LED 1

TF-Bus

www.Grenton.com

TF-Bus

TF-Bus

TF-Bus


GRENTON LED RGB RGB-042-T-16

LED RGB LIGHTING CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

Enables smooth and full control of decorative lighting using LED RGB technology. • dimming function – allows it to operate as a three-channel dimmer • full freedom when setting the color: RGB or HSV model • 16.8 million colors • enables you to adjust both the saturation and hue • smooth transition when changing color, saturation, and intensity • enables you to set the ramp (transition time) for transitions between colors, saturation, and intensity of light

www.Grenton.com

v. 1.0


GRENTON LED RGB

LED RGB LIGHTING CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Brightness value (range: 0 - 1)

Hue

Color hue value as per the HSV model (0 - 360)

Saturation

Color saturation value (0 - 1)

Rvalue

R component value (0 - 255) - Red

Gvalue

G component value (0 - 255) - Green

Bvalue

B component value (0 - 255) - Blue

#RGB

Color value as per the RGB model “#RRGGBB” (specified in HEX)

RampTime

Time value of increment of color and brightness (ms)

MinValue

Minimum value which Value can adopt. Attempting to set a lower value will generate an error.

MaxValue

Maximum value which Value can adopt. Attempting to set a higher value will generate an error.

Rcorrection

White correction - channel R (0 - 10,000), default 10,000

Gcorrection

White correction - channel G (0 - 10,000), default 8,333

Bcorrection

White correction - channel B (0 - 10,000), default 8,333

METHODS Name

Description

SetValue

Sets output value (0 - 1)

SetHue

Sets hue value (0 - 360)

SetSaturation

Sets saturation value (0 - 1)

SetRvalue

Sets R component value (0 - 255)

SetGvalue

Sets G component value (0 - 255)

SetBvalue

Sets B component value (0 - 255)

Set#RGB

Sets RGB value using the “#RRGGBB” string

HoldValue

Executes illumination/dimming function

HoldHue

Executes smooth hue transition

Switch

Changes the output value from 0 to 1 or from 1 to 0. The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds) The second parameter is the ramp (time of value increments) which is optional. If this parameter is not specified, the default ramp is used

SwitchOn

Sets output value to MaxValue

SwitchOff

Sets output value to MinValue

SetRampTime

Sets value of increment of color and input (ms)

SetMax

Sets MaxValue

SetMin

Sets MinValue

www.Grenton.com


GRENTON LED RGB

LED RGB LIGHTING CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

EVENTS Name

Description

OnChange

Event occurring when changing the output state

OnSwitchOn

Event occurring when the output state is changed from = 0 to >0

OnSwitchOff

Event occurring when “0” is set at the output

OnRaiseValueSet

Event occurring when the set value is higher than the current value

OnLowerValueSet

Event occurring when the set value is lower than the current value

OnOutOfRange

Event occurring when setting a value which is higher than the maximum value or lower than the minimum value

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

4.7 mA

weight

38 g

dimensions (H/W/D)

52/57/21 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

O to +40°C

maximum load

10 A - total for all channels

WIRING DIAGRAM TF-Bus

TF-Bus

TF-Bus

TF-Bus

LED 3

LED Blue

LED 2

LED Green

LED 1

LED Red 12 VDC

COM

COM 12 VDC

www.Grenton.com


GRENTON RELAYx2 REL-019-T-01

RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY

The relay output module allows you to control any electrical device without the need to use additional control relays. • two relay outputs • enables you to connect a direct load up to 3.6 kVA • enables the following functions: switching, continuous activation and specific-time activation • signals output state with a diode

www.Grenton.com

v. 1.0


GRENTON RELAYx2 DIN

RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns 1 for output set at “On” and 0 for output set at “Off”

StatisticState Load

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device Multiplier of measured value. For StatisticState: Continous - consumption value per unit time;

METHODS Name

Description

SetValue

SetValue Sets output value to 1 or 0

Switch

Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)

SwitchOn

Sets output value to 1

SwitchOff

Sets output value to 0

EVENTS Name

Description

OnChange

Occurs when a change in the state takes place (regardless of the value)

OnSwitchOn

Occurs when “On” is set at output

OnSwitchOff

Occurs when “Off” is set at output

TECHNICAL SPECIFICATIONS DC supply

5V

average current input

4.18 mA

max. current input

112 mA

contact arrangement

2x NO

weight

82 g

dimensions (H/W/D)

58/36/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

2

operating temperature range

O to +40°C

maximum load

3,600 VA per channel

www.Grenton.com


GRENTON RELAYx2 DIN

RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY

WIRING DIAGRAM

L

~230 V

N

Receiver

NO

TF-Bus

TF-Bus

www.Grenton.com


GRENTON RELAYx4 REL-020-T-11

RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY

The relay output module allows you to control any electrical device without the need to use additional control relays. • four relay outputs • enables you to connect a direct load up to 3.6 kVA • enables the following functions: switching, continuous activation and specific-time activation • signals output state with a diode

www.Grenton.com

v. 1.0


GRENTON RELAYx4

RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns 1 for output set at “On” and 0 for output set at “Off”

StatisticState Load

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device Multiplier of measured value. For StatisticState: Continous - consumption value per unit time

METHODS Name

Description

SetValue

SetValue Sets output value to 1 or 0

Switch

Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)

SwitchOn

Sets output value to 1

SwitchOff

Sets output value to 0

EVENTS Name

Description

OnChange

Occurs when a change in the state takes place (regardless of the value)

OnSwitchOn

Occurs when “On” is set at output

OnSwitchOff

Occurs when “Off” is set at output

TECHNICAL SPECIFICATIONS DC supply

5V

average current input

4.16 mA

max. current input

220 mA

contact arrangement

4x NO

weight

146 g

dimensions (H/W/D)

58/71/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

4

operating temperature range

O to +40°C

maximum load

3,600 VA per channel

www.Grenton.com


GRENTON RELAYx4

RELAY OUTPUT MODULE FOR DIN RAIL ASSEMBLY

WIRING DIAGRAM L

~230V

N

Receiver

NO

TF-Bus

TF-Bus

www.Grenton.com


GRENTON RELAYx2 REL-030-T-01

RELAY OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

Allows you to control any electrical device without the need to use additional control relays. • Two relay outputs • Enables you to connect a direct load up to 1.8 kW • Enables the following functions: switching, continuous activation, and specific-time activation

www.Grenton.com

v. 1.0


GRENTON RELAYx2

RELAY OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns 1 for output set at “On” and 0 for output set at “Off”

StatisticState Load

Measurement type. Off - turned off; Continuous - Load measurement throughout the machine cycle/Load measurement over the entire life cycle of the device Multiplier of measured value. For StatisticState: Continous - consumption value per unit time

METHODS Name

Description

SetValue

SetValue Sets output value to 1 or 0

Switch

Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)

SwitchOn

Sets output value to 1

SwitchOff

Sets output value to 0

EVENTS Name

Description

OnChange

Occurs when a change in the state takes place (regardless of the value)

OnSwitchOn

Occurs when “On” is set at output

OnSwitchOff

Occurs when “Off” is set at output

TECHNICAL SPECIFICATIONS DC supply

5V

average current input

4.18 mA

max. current input

112 mA

contact arrangement

2x NO

weight

46 g

dimensions (H/W/D)

52/57/21 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

O to +40°C

maximum load

1,800 VA per channel

www.Grenton.com


GRENTON RELAYx2

RELAY OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

WIRING DIAGRAM

TF-Bus

TF-Bus

NO

Receiver

~230V

L N

www.Grenton.com


GRENTON RELAYx2 Z-Wave REL-039-Z-07

WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

Allows you to control any electrical device without the need to use additional control relays. • two 230 V outputs • enables you to connect a direct load up to 1,800 VA • enables the following functions: switching, continuous activation, and specific-time activation • allows you to connect two 230 V inputs • Inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • operates with 230 V supply • communicates with other wireless modules using a mesh network

www.Grenton.com

v. 1.0


GRENTON RELAYx2 Z-Wave

WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

Value

Returns 1 for output set at “On” and 0 for output set at “Off”

METHODS Name

Description

SetValue

SetValue Sets output value to 1 or 0

Switch

Changes the output value from 0 to 1 or from 1 to 0.The first parameter is the time of change: - 0 – switches output to continuous mode - num – switches output for a time specified by a parameter (in milliseconds)

SwitchOn

Sets output value to 1

SwitchOff

Sets output value to 0

EVENTS Name

Description

OnChange

Occurs when a change in the state takes place (regardless of the value)

OnSwitchOn

Occurs when “On” is set at output

OnSwitchOff

Occurs when “Off” is set at output

www.Grenton.com


GRENTON RELAYx2 Z-Wave

WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

INPUT PROPERTIES CHARACTERISTICS Name

Description

Value

Returns input state as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs

METHODS Name

Description

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at the input

OnSwitchOff

Occurs when the low state is set at the input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON RELAYx2 Z-Wave

WIRELESS 230 V OUTPUT MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS AC supply

230 V

average current input

2 mA

max. current input

6 mA

Z-Wave frequency

868 HMz

weight

35 g

dimensions (H/W/D)

19/45/36 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

0 to +40°C

maximum load

1,800 VA per channel

WIRING DIAGRAM

Receiver

~230 V

www.Grenton.com

L N


GRENTON SMART PANEL SPS-001-T-01

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY AND HAND GESTURE CONTROL

Replacing traditional wall switches, Smart Panel allows to control not only the light, but also any device in a smart home. The Panel provides information from sensors, system parameters or its functional data. The versatile and intuitive control interface make it easy and quick to control an individual device or a whole home. • smart design matching every interior • four touch buttons, executing up to four independent functions • each button can signal corectness of activation or errors: ShowOK and ShowError • OLED screen • sound signals • proximity sensor and hand gesture control • temperature and light sensors • unlimited functionality - wide programming possibility www.Grenton.com

v. 1.2


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

BUTTONS PARAMETERS CHARACTERISTICS Name

Description

Value

Returns input state as 0 or 1

Mode

Returns the selected mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs

Label

The text that describes the button

IconA

The file name of the icon assigned to the button in monostable and bistable mode in the OFF position. The name preceded by '~' displays the graphic in negative. IconA has priority on the Label feature

IconB

The file name of the icon assigned to the button in bistable mode in the ON position. The name preceded by '~' displays the graphic in negative

METHODS

2

Name

Description

SetMode

Sets mode of button action (0 - monostabilny (monostable), 1 - bistabilny (bistable), 2 - zablokowany (locked)). In locked mode, the diode is illuminated in continous red light

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

ShowError

Causes the red diode on the button to flash for 2 seconds (frequency 500 ms). The green diode on the button is off

ShowOK

Causes the green diose on the button to flash for 2 seconds (frequency 500 ms). The red diode on the button is off

LedSwitchOn

Activates the green diode on the button

LedSwitchOff

Deactivates the green diode on the button

SetLabel

Sets Label value

SetIconA

Sets IconA value

SetIconB

Sets IconB value

www.Grenton.com


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval value

OnClick

Occurs after pressing the button for less than 500 ms

PANEL PARAMETERS CHARACTERISTICS Name

Description

GestureIconUp

The BMP file name of the icon for gesture Up (without extension)

GestureIconDown

The BMP file name of the icon for gesture Down (without extension)

GestureIconLeft

The BMP file name of the icon for gesture Left (without extension)

GestureIconRight

The BMP file name of the icon for gesture Right (without extension)

ProximitySens

Sensitivity of the proximity sensor

ProximityTimeout

The time after which the display will be blanked

ProximityValue

Proximity sensor value

BuzzerValue

Sound indication control (ON/OFF)

VibraValue

Vibration control (ON/OFF)

www.Grenton.com

3


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

METHODS Name

Description

SwitchOnDisplay

Wakes the display from sleep mode

ShowButtons

Changes display mode into "buttons". Clears the display and shows the icons (or text) for every button

ClearScreen

Clears the display in "freedraw" mode

PrintText

Displays the text in "freedraw" mode

PrintFloat

Displays the float number in "freedraw" mode

DrawLine

Draws the line in "freedraw" mode

DrawPoint

Draws the point in "freedraw" mode

DrawIcon

Draws the icon (bmp) in "freedraw" mode

DisplayContent

Displays the memory graphic buffer content. Changes display mode to "freedraw"

SetGestureIconUp

Sets the icon for gesture Up

SetGestureIconDown

Sets the icon for gesture Down

SetGestureIconLeft

Sets the icon for gesture Left

SetGestureIconRight

Sets the icon for gesture Right

SetProximitySens

Sets the ProximitySens value

SetProximityTimeout

Sets the ProximityTimeout value (in seconds)

SetBuzzerValue

Sets the BuzzerValue

SetVibraValue

Sets the VibraValue

EVENTS Name

Description

OnGestureUp

Occurs after gesture Up

OnGestureDown

Occurs after gesture Down

OnGestureLeft

Occurs after gesture Left

OnGestureRight

Occurs after gesture Right

OnProximityDetect

Occurs when the panel detects the object

GESTURES

Gesture Up

4

www.Grenton.com

Gesture Down

Gesture Left

Gesture Right


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

PREINSTALLED PICTOGRAMS

aircold

airwarm

airwmcd

alarmgo

alarmset

alarm

arrdown

arrup

automat

back

brekfast

brektime

chektime

cold

concierg

dontdist

doorbel

drink1

drink2

economic

elevato1

elevato2

fan1

fan2

fire

gym

heatoff

heaton

lamp1off

lamp1on

lamp2off

lamp2on

lamp3off

lamp3on

laundry

locked

luggtrol

minus

music

next

onoff

play

plus

presence

previous

safe

sauna

sauna2

sday

sdefault

servlea

shclosed

shgroup

shopen

sleep

smood

smovie

snight

socket

sparty

www.Grenton.com

5


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

stoppaus

sun

taxi

temp

tempcold

tempwarm

unlocked

warning

winclose

wingroup

winopen

SENSORES PARAMETERS CHARACTERISTICS Name

Description

Value

Input value: for temperature sensor from 0.0 to 45.0 (°C)

Threshold

Hysteresis size (accuracy 0.1°C) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRise

Sensitivity

Time (in ms) for which the sampled values are averaged

MinValue

Minimum value of the Value characteristic after exceeding which the OnOutOfRange event is generated

MaxValue

Maximum value of the Value characteristic after exceeding which the OnOutOfRange event is generated

EVENTS

6

Name

Description

OnChange

Event resulting from changing input state

OnRaiseValue

Event resulting from exceeding the upper threshold of hysteresis

OnLowerValue

Event resulting from exceeding the lower threshold of hysteresis

OnOutOfRange

Event resulting from exceeding any range

www.Grenton.com


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

TECHNICAL SPECIFICATIONS DC supply

5 - 24V

average current input in a standby mode for 5 V

20 mA

max. current input for 5 V

80 mA

weight

120 g

dimmensions (H/W/D)

surface part: 80/80/10 mm, concealed part: Ø 50 mm / h: 22 mm

operating temperature range

0 - 45°C (without condesantion)

microSD CARD INSTALLATION The card should be installed with the power supply turned off.

1

2

3

4 A B

www.Grenton.com

7


GRENTON SMART PANEL

FOUR CAPACITIVE BUTTONS TOUCH PANEL WITH THE OLED DISPLAY

WIRING DIAGRAM 1

2

flush box

fastening ring

3

TF-Bus

4

click!

push

8

www.Grenton.com

flush box


GRENTON ROLLER SHUTTER RSH-045-T-06

ROLLER SHUTTER CONTROL MODULE FOR DIN RAIL ASSEMBLY

Allows you to control any roller shutter drive. • equipped with two control contacts (up/down, left/right) • for installation in electrical switch rooms • allows you to control drives with a maximum capacity of 3.6 kVA

www.Grenton.com

v. 1.0


GRENTON ROLLER SHUTTER

ROLLER SHUTTER CONTROL MODULE FOR DIN RAIL ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

M1

State of M1 relay

M2

State of M2 relay

State

Device state. 0 - no movement, 1 - moving downwards, 2 - moving upwards

MaxTime

Default Time parameter value. Maximum movement time

METHODS Name

Description

Up

Roller Shutter Up or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Down

Roller Shutter Down or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Start

Roller Shutter Up if the preceding motion was Down or Roller Shutter Down if the preceding motion was Up. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Stop

Stop if moving

Hold

Hold with direction change

HoldUp

Hold always up

HoldDown

Hold always down

EVENTS Name

Description

OnChange

Occurs when changing the state of any of the outputs

OnUp

Occurs when changing the Stop state to the Up state

OnDown

Occurs when changing the Stop state to the Down state

OnStart

Occurs when Start is requested

OnStop

Occurs when Stop is requested

www.Grenton.com


GRENTON ROLLER SHUTTER

ROLLER SHUTTER CONTROL MODULE FOR DIN RAIL ASSEMBLY

TECHNICAL SPECIFICATIONS DC supply

5V

average current input

4.18 mA

max. current input

112 mA

weight

82 g

dimensions (H/W/D)

58/36/90 mm

max. connection wire section

≤ 2.5 mm2

size [DIN]

2

operating temperature range

O to +40°C

maximum load

3,600 VA

WIRING DIAGRAM L

~230V

N

M

TF-Bus

TF-Bus

www.Grenton.com


GRENTON ROLLER SHUTTER RSH-044-T-02

ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

Allows you to control any roller shutter drive. • equipped with two control contacts (up/down, left/right) • small size – fits into a P60 box under the ancillary equipment • allows you to control drives with a maximum capacity of 1.8 kVA

www.Grenton.com

v. 1.0


GRENTON ROLLER SHUTTER

ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

M1

State of M1 relay

M2

State of M2 relay

State

Device state. 0 - no movement, 1 - moving downwards, 2 - moving upwards

MaxTime

Default Time parameter value. Maximum movement time

METHODS Name

Description

Up

Roller Shutter Up or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Down

Roller Shutter Down or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Start

Roller Shutter Up if the preceding motion was Down or Roller Shutter Down if the preceding motion was Up. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Stop

Stop if moving

Hold

Hold with direction change

HoldUp

Hold always up

HoldDown

Hold always down

EVENTS Name

Description

OnChange

Occurs when changing the state of any of the outputs

OnUp

Occurs when changing the Stop state to the Up state

OnDown

Occurs when changing the Stop state to the Down state

OnStart

Occurs when Start is requested

OnStop

Occurs when Stop is requested

www.Grenton.com


GRENTON ROLLER SHUTTER

ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS DC supply

5V

average current input

4.18 mA

max. current input

112 mA

weight

46 g

dimensions (H/W/D)

52/57/21mm

max. connection wire section

≤ 1.5mm2

operating temperature range

O to +40°C

maximum load

1,800 VA

WIRING DIAGRAM TF-Bus

TF-Bus

M

~230V

L N

www.Grenton.com


GRENTON ROLLER SHUTTER Z-Wave RSH-040-Z-02

WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

Allows you to control any roller shutter drive. • equipped with two control contacts (up/down, left/right) • two 230 V outputs • inputs are fully configurable • small size – fits into a P60 box under the ancillary equipment • operates with 230 V supply • ccommunicates with other wireless modules using a mesh network

www.Grenton.com

v. 1.0


GRENTON ROLLER SHUTTER Z-Wave

WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

CONFIGURATION PARAMETERS CHARACTERISTICS Name

Description

M1

State of M1 relay

M2

State of M2 relay

State

Output state: 0 – stopped, 1 – moving up, 2 – moving down

MaxTime

Default value for the Time parameter, if “0” was entered

METHODS Name

Description

Up

Roller Shutter Up or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Down

Roller Shutter Down or Stop if moving. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Start

Roller Shutter Up if the preceding motion was Down or Roller Shutter Down if the preceding motion was Up. Parameter Time: - 0 - output is active for the time specified in MaxTime - number - output is active for specified time

Stop

Stop if moving

Hold

Hold with direction change

HoldUp

Hold always up

HoldDown

Hold always down

EVENTS Name

Description

OnChange

Occurs when changing the state of any of the outputs

OnUp

Occurs when changing the Stop state to the Up state

OnDown

Occurs when changing the Stop state to the Down state

OnStart

Occurs when Start is requested

OnStop

Occurs when Stop is requested

www.Grenton.com


GRENTON ROLLER SHUTTER Z-Wave

WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

INPUT PROPERTIES CHARACTERISTICS Name

Description

Value

Returns input state as 0 or 1

Inertion

Minimum interval in milliseconds which has to pass between presses of a button so that it is interpreted as a new pressing activity

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs

METHODS Name

Description

SetInertion

Sets Inertion value

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at the input

OnSwitchOff

Occurs when the low state is set at the input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval Value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON ROLLER SHUTTER Z-Wave

WIRELESS ROLLER SHUTTER CONTROL MODULE FOR FLUSH-MOUNT ASSEMBLY

TECHNICAL SPECIFICATIONS AC supply

230 V

average current input

2 mA

max. current input

3 mA

Z-Wave frequency

868 MHz

contact arrangement

2x NO

weight

35 g

dimensions (H/W/D)

19/45/36 mm

max. connection wire section

≤ 1.5 mm2

operating temperature range

0 to +40°C

maximum load

1,800 VA

WIRING DIAGRAM

M

~230V

www.Grenton.com

L N


GRENTON TOUCH PANEL TPA-023-T-0X

TOUCH PANEL WITH 4 BUTTONS

The touch panel replaces traditional light switches. • 4 buttons • each button can execute up to four independent functions • features a built-in temperature sensor • each button can signal correctness of activation or errors ShowOK and ShowError • available in dierent colors

www.Grenton.com

v. 1.0


GRENTON TOUCH PANEL TOUCH PANEL WITH 4 BUTTONS

BUTTON PROPERTIES CHARACTERISTICS Name

Description

Value

Returns input state as 0 or 1

Mode

Returns the selected mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs.

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs.

METHODS Name

Description

SetMode

Sets the mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

ShowError

Causes the red diode on the button to flash for 2 seconds (frequency 500 ms). The green diode on the button is off

ShowOK

Causes the green diode on the button to flash for 2 seconds (frequency 500 ms). The red diode on the button is off

LedSwitchOn

Activates the green diode on the button

LedSwitchOff

Deactivates the green diode on the button

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON TOUCH PANEL

TOUCH PANEL WITH 4 BUTTONS

SENSOR PROPERTIES CHARACTERISTICS Name

Description

Value

Input value: for temperature sensor from 0.0 to 6553.5 (°C), for light sensor 0 - 100

Threshold

Hysteresis size (accuracy 0.1°C or 0.1%) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRaise

Sensitivity

Time (in ms) for which the sampled values are averaged

MinValue

Minimum value of the Value characteristic after exceeding which the OnOutRange event is generated

METHODS Name

Description

SetThreshold

Changes hysteresis size

SetSensitivity

Changes sensitiv ity value

SetMinValue

Sets minimum value for the Value characteristic

SetMaxValue

Sets maximum value for the Value c haracteristic

EVENTS Name

Description

OnChange

Event resulting from changing input state

OnRaise

Event resulting from exceeding the upper threshold of hysteresis

OnLower

Event resulting from exceeding the lower threshold of hysteresis

OnOutOfRange

Event resulting from exceeding any range

www.Grenton.com


GRENTON TOUCH PANEL TOUCH PANEL WITH 4 BUTTONS

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input

36.3 mA

weight

200 g

dimensions (H/W/D)

160/80/18 mm

operating temperature range

O to +40°C

WIRING DIAGRAM 1

2

3

click!

TF-Bus

www.Grenton.com


GRENTON TOUCH PANEL TPA-02X-T-0X

TOUCH PANEL WITH 8 BUTTONS

The touch panel replaces traditional light switches. • 8 buttons • each button can execute up to four independent functions • features a built-in temperature sensor • each button can signal correctness of activation or errors Show OK and Show ERROR • available in dierent colors

www.Grenton.com

v. 1.0


GRENTON TOUCH PANEL TOUCH PANEL WITH 8 BUTTONS

BUTTON PROPERTIES CHARACTERISTICS Name

Description

Value

Returns input state as 0 or 1

Mode

Returns the selected mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.

HoldDelay

Time in milliseconds after which, when pressing and holding a button, the OnHold event occurs.

HoldInterval

Cyclical interval in milliseconds after which, when pressing and holding a button, the OnHold event occurs.

METHODS Name

Description

SetMode

Sets the mode of button action (0 – monostable, 1 – bistable, 2 – locked). In locked mode, the diode is illuminated in continuous red light.

SetHoldDelay

Sets HoldDelay value

SetHoldInterval

Sets HoldInterval value

ShowError

Causes the red diode on the button to flash for 2 seconds (frequency 500 ms). The green diode on the button is off

ShowOk

Causes the green diode on the button to flash for 2 seconds (frequency 500 ms). The red diode on the button is off

LedSwitchOn

Activates the green diode on the button

LedSwitchOff

Deactivates the green diode on the button

EVENTS Name

Description

OnChange

Occurs when a change in the input state takes place (regardless of the value)

OnSwitchOn

Occurs when the high state is set at input

OnSwitchOff

Occurs when the low state is set at input

OnShortPress

Occurs after pressing the button for 500 - 2000 ms

OnLongPress

Occurs after pressing the button for two seconds

OnHold

Occurs for the first time after HoldDelay time passes and then cyclically every HoldInterval value

OnClick

Occurs after pressing the button for less than 500 ms

www.Grenton.com


GRENTON TOUCH PANEL

TOUCH PANEL WITH 8 BUTTONS

SENSOR PROPERTIES CHARACTERISTICS Name

Description

Value

Input value: for temperature sensor from 0.0 to 6553.5 (°C), for light sensor 0 - 100

Threshold

Hysteresis size (accuracy 0.1°C or 0.1%) specifying the sensitivity when the following events are generated: OnChange, OnLower, OnRaise

Sensitivity

Time (in ms) for which the sampled values are averaged

MinValue

Minimum value of the Value characteristic after exceeding which the OnOutRange event is generated

METHODS Name

Description

SetThreshold

Changes hysteresis size

SetSensitivity

Changes sensitiv ity value

SetMinValue

Sets minimum value for the Value characteristic

SetMaxValue

Sets maximum value for the Value c haracteristic

EVENTS Name

Description

OnChange

Event resulting from changing input state

OnRaise

Event resulting from exceeding the upper threshold of hysteresis

OnLower

Event resulting from exceeding the lower threshold of hysteresis

OnOutOfRange

Event resulting from exceeding any range

www.Grenton.com


GRENTON TOUCH PANEL TOUCH PANEL WITH 8 BUTTONS

TECHNICAL SPECIFICATIONS DC supply

5V

max. current input [mA]

36.3 mA

weight

200 g

dimensions (H/W/D) [mm]

160/80/18

operating temperature range

0 to +40°C

WIRING DIAGRAM 1

2

3

click!

TF-Bus

www.Grenton.com


Turn static files into dynamic content formats.

Create a flipbook