RETAINING WALL 16" HIGH
16' [4.88m]
50' [15.24m]
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
DRIVEWAY PAVING STONE
59'-612" [18.15m]
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
Exisiting Patio
19'-6" [5.94m]
Proposed Spice Kitchen and Powder
RETAINING WALL 16" HIGH
53' [16.15m]
104'-512" [31.84m]
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
PAVING STONE
19'-6" [5.94m] Exisiting Building 13330 20 AVE Surrey BC
PAVING STONE
Proposed Shed
93' [28.35m]
DN 2R
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
24' [7.32m]
16' [4.88m]
48'-114" [14.66m]
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
20' [6.09m]
214' [65.23m]
SHEET TITLE:
SITE
50' [15.24m]
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
1/8"=1'-0"
V10
SHEET NO:
A1
UDC DESIGN CENTER LTD
BUILDING - INTERIOR DESIGNERS UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
REAR TOP FLOOR COVERED DECK REMOVED TO OPEN DECK
SHEET TITLE:
COSMOS OVERVIEW
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
1/8"=1'-0"
V10
SHEET NO:
54'-0"
4'-3"
6'-11" 4040RS
7'-0"
3'-11"
9'-4" 2668
50
3050RS
3068
16
3050RS
2060RS
50
5060RS
2060RS
7'-8"
2668
13'-1"
16'-9"
9'-0" 2668
37'-11" 2668
4'-8"
2668
7'-3"
4068
S
2668
3'-4"
8'-10"
4'-6"
11'-6" [3.51m]
2650
5' [1.52m]
1'-0"
5040RS
12'-0" 2668
9080
3016 5040RS
5'-6"
9080
10'-7"
9'-4"
S
Tub-Shower 2
6'-10"
2' [0.61m]
16'-3"
8'-0"
6'-0"
5068
4668
34'-2"
3680
2668
4'-0"
2668
2668
1 Step Down
S
1680
8'-2"
6'-0"
2668
5'-9"
DN
1640
1'-8" 1'-1"
24'-2"
5'-11"
6'-0"
11'-0"
44'-0" 50'-0"
4030
3068
1668
3'-9"
2668
4068
2042
3068
1640
1'-1"1'-2"
9'-11"
3068
2042
6'-0"
3068
UP
10'-0"
2668
2668
4'-0"
5050RS
S
Tub-Shower 2
6'-11"
2668
S
6'-0"
15'-10"
4040RS
2668
9'-8"
7'-10" 1'-4"1'-10"
Rect (small) [55] Slipper Bathtub
2668
7'-8"
1'-4"
5040RS
Rect (small) [48]
7'-9"
15'-8" 58'-1"
BUILDING - INTERIOR DESIGNERS
2030RS
Existing Bay Window
S
SKYLIGHT 1936
6'-0"
10'-10"
2'-11"
5050
SMOKE ALARM & CARBON MONOXIDE (CO) ALARM
12'-7"
6'-4"
4036RS
PROPOSED EXTENSION
S CO
ISLAND 8'-0" X 4'-5"
1'-7"
9'-9"
27'-2" [8.28m]
3'-11"
BLT-IN COFFER MAKER
Double Door Refrigerator 2
2'-0"
16'-10"
16
tall cabinet Double Door Refrigerator 1
5'-1"
9'-3"
29'-10"
2668
4'-0"
BLT-IN OVEN
7'-7"
Tub-Shower 2
tall cabinet
Chateau Range
8'-3"
7'-5"
3'-0"
2030RS
3068
Dishwasher
UDC DESIGN CENTER LTD
2'-9"
5'-7"
3'-11"
14'-9"
11'-4"
9'-612" [2.91m]
7'-3"
15'-1"
10'-0"
54'-0"
2'-1"
14'-2"
16'-6"
A
A1
A A1
24'-2" [7.37m]
5350
1750
5'-8"
3'-1"
1750
8'-9"
17'-6"
2'-7" 1'-8"
6'-3" 8'-10"
4'-7"
4'-5"
6'-0"
4'-6"
4'-6"
2'-1"
17'-1"
10'-8" 54'-0"
14'-0"
6050RS
5'-1"
4'-11"
3'-8"
3'-10"
5'-11"
3'-0"
2'-5"
6'-5"
11'-8"
7'-3"
A A1
10'-0"
7'-6"
11'-3"
25'-3" S
54'-0"
A A1
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
SHEET TITLE:
MAIN AND UPPER
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
1
V10
4 "=1'-0"
SHEET NO:
A3
4'-212" [1.28m] 4'-212" [1.28m]
12 9.5
12
12
9.5
9.5
9 1/2 : 12
1750
5350
MEAN ROOF LVL.
U/S CEILING LVL.
3016
1750
5040RS
5040RS
9' [2.74m]
12 12
stone or stucco 12 4 : 12
4
1680 3680
6050RS 5050RS
9080
9080
10' [3.05m]
23'-212" [7.07m]
SECOND FLOOR LVL.
MAIN FL. LVL.
FRONT ELEVATION
4'-212" [1.28m] 4'-212" [1.28m]
scale: 14" = 1'-0"
9 1/2 : 12
9 1/2 : 12
ROOF RIDGE LVL. 99.67
MEAN ROOF LVL.
U/S CEILING LVL.
9' [2.74m]
9 1/2 : 12
12 : 12
hardy panel or stucco SECOND FLOOR LVL.
RIGHT ELEVATION TOTAL AREA: 914 SQ. FT. 84.9 SQM DISTANCE TO PROPERTY LINE: 19'-6" [5.9M] ≈ 6.0M MAX. ALLOWABLE UNPROTECTED AREA @ 34.0% = 311 SQ. FT. PROPOSED UNPROTECTED AREA: = 12 SQ. FT
4030
12
3068
10' [3.05m]
4 : 12
23'-212" [7.07m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
ROOF RIDGE LVL. 99.67
RIGHT ELEVATION scale: 14"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
MAIN FL. LVL.
= 1'-0"
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
SHEET TITLE:
FRONT AND RIGHT
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
1
V10
4 "=1'-0"
SHEET NO:
A4
4'-212" [1.28m] 4'-212" [1.28m]
9 1/2 : 12
4036RS
U/S CEILING LVL.
2030RS
3068
hardy panel or stucco
1'-6" [0.46m]
2060
5060
2060
4040 2030
3050RS
3050RS
10' [3.05m]
23'-212" [7.07m]
SECOND FLOOR LVL.
3068
MAIN FL. LVL.
REAR ELEVATION
4'-212" [1.28m] 4'-212" [1.28m]
scale: 14" = 1'-0"
9 1/2 : 12
1640 6
12 : 12
hardy panel or stucco
ROOF RIDGE LVL. 99.67
MEAN ROOF LVL.
U/S CEILING LVL.
9' [2.74m]
1640 6
SECOND FLOOR LVL.
12
RIGHT ELEVATION
1'-6" [0.46m]
TOTAL AREA: 972 SQ. FT. 90.3 SQM DISTANCE TO PROPERTY LINE: 19'-6" [5.9M] ≈ 6.0M MAX. ALLOWABLE UNPROTECTED AREA @ 34.0% = 330 SQ. FT. PROPOSED UNPROTECTED AREA: = 44.48 SQ. FT
4040RS 16
2042FX
2042FX
8.24
8.24
10' [3.05m]
4
23'-212" [7.07m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
MEAN ROOF LVL.
9' [2.74m]
5040
ROOF RIDGE LVL. 99.67
MAIN FL. LVL.
LEFT ELEVATION scale: 14" = 1'-0"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
SHEET TITLE:
REAR AND LEFT
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
1
V10
4 "=1'-0"
SHEET NO:
A5
4'-212" [1.28m] 4'-212" [1.28m]
1'-8" 7'-2"
13'-9"
3'-3"
1'-0"
Under Counter Fridge
13'-9"
3068
3068
12'-6"
1'-8"
1'-8"
1'-8"
10' [3.05m]
23'-212" [7.07m]
1'-6" [0.46m]
BBQ
SECOND FLOOR LVL. 4
6'-8"
1'-8"
21'-6"
5068
112" CONC. TOPPING
LAYOUT PLAN
MAIN FL. LVL.
scale: 14" = 1'-0" 300 SQFT
7
section 7'-23 4" [2.20m]
scale: 14" = 1'-0"
5
- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
2
EAVES:
- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION - 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)
6
EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
7
stone or stucco
RIGHT ELEVATION
FRONT ELEVATION
INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY
4
BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL
- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3
MAIN FLOOR (1 hr FRR):
5' [1.52m]
ROOF:
9' [2.74m]
1
12 6
4' [1.22m]
SECTIONAL DETAILS AND SPECIFICATIONS: 16'-23 4" [4.94m]
BUILDING - INTERIOR DESIGNERS
FIREPLACE
vaulted ceiling
5
2668
7'-9"
6'-0"
2'-0"
112" CONC. TOPPING
UDC DESIGN CENTER LTD
U/S CEILING LVL.
9' [2.74m]
3
7'-9" 10"
7 1/2 : 12
4 1/2 : 12
MEAN ROOF LVL.
1'-8"
ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM
21'-6"
10'-5"
DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
ATTIC
ROOF RIDGE LVL. 99.67
FOUNDATION WALLS:
scale: 14" = 1'-0"
scale: 14" = 1'-0"
- 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE
INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL
LEFT ELEVATION
REAR ELEVATION
scale: 14" = 1'-0"
scale: 14" = 1'-0"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
SHEET TITLE:
Section and Shed
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
1
V10
4 "=1'-0"
SHEET NO:
A6
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
∙
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
SHEET TITLE:
ENERGY DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
SHEET NO:
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
N.T.S.
V10
D1
HEADER
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING
MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
4" ADHERED FLASHING MEMBRANE
INTERIOR
100 mm (4")
FLOOR FINISH ON CONCRETE TOPPING
SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN
MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)
2"CONTINUOUS FLANGE AT PERIMETER OF HOOD
ROD AND SEALANT STUD @ 16" O.C
2"
2
SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
1 MIN 2"
BLDG. PAPER
4.06
23.03
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
3.99
22.61
0.68
4.11
23.29
ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW
ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM
RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12
R 0.44 0.00 0.77 50.0 0.00 0.45 0.68
SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)
2X10 FLOOR JOISTS
SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
9.21
50.34
FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE
RSI 0.03 0.12 0.00 0.15 4.99 0.00
R 0.17 0.68 0.00 0.83 28.00 0.00
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
5.29
29.68
TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME
USI
U
1.4
0.246
1" 2
SEPERATION AIR SPACE
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
1 MIN.
PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME
VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12
2a
2 SEALANT OR GASKET (A.B.)
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
12mm (1/2")
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)
1X2 STRAPPING
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
1.5" SILL PLATE
EXTERIOR
BUILDING - INTERIOR DESIGNERS
STUCCO CLADDING
- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )
INTERIOR
AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION
THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)
SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)
FLASHING & COUNTER FLASHING
SEALANT OR GASKET (A.B.)
ASPHALT IMPREGNATED PAPER
INSECT SCREEN - NO DAMPERS
EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD
GRID
1/2″ (12.7 MM) PLYWOOD SHEATHING
2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT
POLYETHYLENE VAPOR BARRIER
ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)
1/2″ (12.7 MM) GYPSUM BOARD
MIN. 2% SLOPE TO DRAIN
2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING
SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL
INSULATION GUARD
POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)
EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
GASKET (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)
W-1
SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING
SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING
INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)
HOUSEWRAP AT HEADER (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD
BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE
25mm (1")
ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)
2" MIN.
FILTER CLOTH
CEMENT OR ACRYLIC STUCCO PARGING
SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS
DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
8" CONC. FOUNDATION WALL
FINISHED GRADE
4" EXTRUDED POLYSTYRENE R-5/in. 1" 2
REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL
DRYWALL FINISH
912"
INSECT SCREEN
VENTED ALUMINUM SOFFIT PANELS
FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06
512"
CEMENT OR ACRYLIC STUCCO PARGING
8" MINIMUM
SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL HOUSEWRAP (A.B.) TO FRAMING
CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL
ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER
INTERIOR
1/2"
UDC DESIGN CENTER LTD
4" FLANGE
25.4mm (1")
R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68
WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
SHEATHING PAPER TO LAP METAL FLASHING
ROD AND SEALANT 1
RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
4" FLANGE 6
WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
EXTERIOR
4"
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI / R VALUE CALCULATIONS FOR ASSEMBLIES
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
GRID
COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.
WOOD FRAMING (STUDS OR STRAPPING)
W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
EXISITNG HOUSE RENOVATION CLIENT: PROJECT:
DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC
REVISION:
Rear Deck Removed Front Elevation Updated Office Room Size Updated
SHEET TITLE:
GENERAL DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
250
DATE:
FEB 2017
FILE NO.
SCALE:
N.T.S.
V10
SHEET NO:
D2