13330 20 ave

Page 1

RETAINING WALL 16" HIGH

16' [4.88m]

50' [15.24m]

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

DRIVEWAY PAVING STONE

59'-612" [18.15m]

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

Exisiting Patio

19'-6" [5.94m]

Proposed Spice Kitchen and Powder

RETAINING WALL 16" HIGH

53' [16.15m]

104'-512" [31.84m]

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

PAVING STONE

19'-6" [5.94m] Exisiting Building 13330 20 AVE Surrey BC

PAVING STONE

Proposed Shed

93' [28.35m]

DN 2R

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

24' [7.32m]

16' [4.88m]

48'-114" [14.66m]

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

20' [6.09m]

214' [65.23m]

SHEET TITLE:

SITE

50' [15.24m]

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

1/8"=1'-0"

V10

SHEET NO:

A1


UDC DESIGN CENTER LTD

BUILDING - INTERIOR DESIGNERS UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

REAR TOP FLOOR COVERED DECK REMOVED TO OPEN DECK

SHEET TITLE:

COSMOS OVERVIEW

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

1/8"=1'-0"

V10

SHEET NO:


54'-0"

4'-3"

6'-11" 4040RS

7'-0"

3'-11"

9'-4" 2668

50

3050RS

3068

16

3050RS

2060RS

50

5060RS

2060RS

7'-8"

2668

13'-1"

16'-9"

9'-0" 2668

37'-11" 2668

4'-8"

2668

7'-3"

4068

S

2668

3'-4"

8'-10"

4'-6"

11'-6" [3.51m]

2650

5' [1.52m]

1'-0"

5040RS

12'-0" 2668

9080

3016 5040RS

5'-6"

9080

10'-7"

9'-4"

S

Tub-Shower 2

6'-10"

2' [0.61m]

16'-3"

8'-0"

6'-0"

5068

4668

34'-2"

3680

2668

4'-0"

2668

2668

1 Step Down

S

1680

8'-2"

6'-0"

2668

5'-9"

DN

1640

1'-8" 1'-1"

24'-2"

5'-11"

6'-0"

11'-0"

44'-0" 50'-0"

4030

3068

1668

3'-9"

2668

4068

2042

3068

1640

1'-1"1'-2"

9'-11"

3068

2042

6'-0"

3068

UP

10'-0"

2668

2668

4'-0"

5050RS

S

Tub-Shower 2

6'-11"

2668

S

6'-0"

15'-10"

4040RS

2668

9'-8"

7'-10" 1'-4"1'-10"

Rect (small) [55] Slipper Bathtub

2668

7'-8"

1'-4"

5040RS

Rect (small) [48]

7'-9"

15'-8" 58'-1"

BUILDING - INTERIOR DESIGNERS

2030RS

Existing Bay Window

S

SKYLIGHT 1936

6'-0"

10'-10"

2'-11"

5050

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

12'-7"

6'-4"

4036RS

PROPOSED EXTENSION

S CO

ISLAND 8'-0" X 4'-5"

1'-7"

9'-9"

27'-2" [8.28m]

3'-11"

BLT-IN COFFER MAKER

Double Door Refrigerator 2

2'-0"

16'-10"

16

tall cabinet Double Door Refrigerator 1

5'-1"

9'-3"

29'-10"

2668

4'-0"

BLT-IN OVEN

7'-7"

Tub-Shower 2

tall cabinet

Chateau Range

8'-3"

7'-5"

3'-0"

2030RS

3068

Dishwasher

UDC DESIGN CENTER LTD

2'-9"

5'-7"

3'-11"

14'-9"

11'-4"

9'-612" [2.91m]

7'-3"

15'-1"

10'-0"

54'-0"

2'-1"

14'-2"

16'-6"

A

A1

A A1

24'-2" [7.37m]

5350

1750

5'-8"

3'-1"

1750

8'-9"

17'-6"

2'-7" 1'-8"

6'-3" 8'-10"

4'-7"

4'-5"

6'-0"

4'-6"

4'-6"

2'-1"

17'-1"

10'-8" 54'-0"

14'-0"

6050RS

5'-1"

4'-11"

3'-8"

3'-10"

5'-11"

3'-0"

2'-5"

6'-5"

11'-8"

7'-3"

A A1

10'-0"

7'-6"

11'-3"

25'-3" S

54'-0"

A A1

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

SHEET TITLE:

MAIN AND UPPER

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

1

V10

4 "=1'-0"

SHEET NO:

A3


4'-212" [1.28m] 4'-212" [1.28m]

12 9.5

12

12

9.5

9.5

9 1/2 : 12

1750

5350

MEAN ROOF LVL.

U/S CEILING LVL.

3016

1750

5040RS

5040RS

9' [2.74m]

12 12

stone or stucco 12 4 : 12

4

1680 3680

6050RS 5050RS

9080

9080

10' [3.05m]

23'-212" [7.07m]

SECOND FLOOR LVL.

MAIN FL. LVL.

FRONT ELEVATION

4'-212" [1.28m] 4'-212" [1.28m]

scale: 14" = 1'-0"

9 1/2 : 12

9 1/2 : 12

ROOF RIDGE LVL. 99.67

MEAN ROOF LVL.

U/S CEILING LVL.

9' [2.74m]

9 1/2 : 12

12 : 12

hardy panel or stucco SECOND FLOOR LVL.

RIGHT ELEVATION TOTAL AREA: 914 SQ. FT. 84.9 SQM DISTANCE TO PROPERTY LINE: 19'-6" [5.9M] ≈ 6.0M MAX. ALLOWABLE UNPROTECTED AREA @ 34.0% = 311 SQ. FT. PROPOSED UNPROTECTED AREA: = 12 SQ. FT

4030

12

3068

10' [3.05m]

4 : 12

23'-212" [7.07m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

ROOF RIDGE LVL. 99.67

RIGHT ELEVATION scale: 14"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

MAIN FL. LVL.

= 1'-0"

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

SHEET TITLE:

FRONT AND RIGHT

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

1

V10

4 "=1'-0"

SHEET NO:

A4


4'-212" [1.28m] 4'-212" [1.28m]

9 1/2 : 12

4036RS

U/S CEILING LVL.

2030RS

3068

hardy panel or stucco

1'-6" [0.46m]

2060

5060

2060

4040 2030

3050RS

3050RS

10' [3.05m]

23'-212" [7.07m]

SECOND FLOOR LVL.

3068

MAIN FL. LVL.

REAR ELEVATION

4'-212" [1.28m] 4'-212" [1.28m]

scale: 14" = 1'-0"

9 1/2 : 12

1640 6

12 : 12

hardy panel or stucco

ROOF RIDGE LVL. 99.67

MEAN ROOF LVL.

U/S CEILING LVL.

9' [2.74m]

1640 6

SECOND FLOOR LVL.

12

RIGHT ELEVATION

1'-6" [0.46m]

TOTAL AREA: 972 SQ. FT. 90.3 SQM DISTANCE TO PROPERTY LINE: 19'-6" [5.9M] ≈ 6.0M MAX. ALLOWABLE UNPROTECTED AREA @ 34.0% = 330 SQ. FT. PROPOSED UNPROTECTED AREA: = 44.48 SQ. FT

4040RS 16

2042FX

2042FX

8.24

8.24

10' [3.05m]

4

23'-212" [7.07m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

MEAN ROOF LVL.

9' [2.74m]

5040

ROOF RIDGE LVL. 99.67

MAIN FL. LVL.

LEFT ELEVATION scale: 14" = 1'-0"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

SHEET TITLE:

REAR AND LEFT

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

1

V10

4 "=1'-0"

SHEET NO:

A5


4'-212" [1.28m] 4'-212" [1.28m]

1'-8" 7'-2"

13'-9"

3'-3"

1'-0"

Under Counter Fridge

13'-9"

3068

3068

12'-6"

1'-8"

1'-8"

1'-8"

10' [3.05m]

23'-212" [7.07m]

1'-6" [0.46m]

BBQ

SECOND FLOOR LVL. 4

6'-8"

1'-8"

21'-6"

5068

112" CONC. TOPPING

LAYOUT PLAN

MAIN FL. LVL.

scale: 14" = 1'-0" 300 SQFT

7

section 7'-23 4" [2.20m]

scale: 14" = 1'-0"

5

- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

2

EAVES:

- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION - 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

6

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

7

stone or stucco

RIGHT ELEVATION

FRONT ELEVATION

INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

4

BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3

MAIN FLOOR (1 hr FRR):

5' [1.52m]

ROOF:

9' [2.74m]

1

12 6

4' [1.22m]

SECTIONAL DETAILS AND SPECIFICATIONS: 16'-23 4" [4.94m]

BUILDING - INTERIOR DESIGNERS

FIREPLACE

vaulted ceiling

5

2668

7'-9"

6'-0"

2'-0"

112" CONC. TOPPING

UDC DESIGN CENTER LTD

U/S CEILING LVL.

9' [2.74m]

3

7'-9" 10"

7 1/2 : 12

4 1/2 : 12

MEAN ROOF LVL.

1'-8"

ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM

21'-6"

10'-5"

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

ATTIC

ROOF RIDGE LVL. 99.67

FOUNDATION WALLS:

scale: 14" = 1'-0"

scale: 14" = 1'-0"

- 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

LEFT ELEVATION

REAR ELEVATION

scale: 14" = 1'-0"

scale: 14" = 1'-0"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

SHEET TITLE:

Section and Shed

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

1

V10

4 "=1'-0"

SHEET NO:

A6


BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

∙

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

SHEET TITLE:

ENERGY DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

SHEET NO:

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

N.T.S.

V10

D1


HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

ROD AND SEALANT STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER

4.06

23.03

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

3.99

22.61

0.68

4.11

23.29

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

2X10 FLOOR JOISTS

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

1" 2

SEPERATION AIR SPACE

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

EXTERIOR

BUILDING - INTERIOR DESIGNERS

STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

INTERIOR

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)

SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

W-1

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

2" MIN.

FILTER CLOTH

CEMENT OR ACRYLIC STUCCO PARGING

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in. 1" 2

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL

DRYWALL FINISH

912"

INSECT SCREEN

VENTED ALUMINUM SOFFIT PANELS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06

512"

CEMENT OR ACRYLIC STUCCO PARGING

8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

1/2"

UDC DESIGN CENTER LTD

4" FLANGE

25.4mm (1")

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4" FLANGE 6

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

EXTERIOR

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

GRID

COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

EXISITNG HOUSE RENOVATION CLIENT: PROJECT:

DAWOOD SHEIKH CIVIC ADDRESS: 13330 20 AVE, SOUTH SURREY, BC

REVISION:

Rear Deck Removed Front Elevation Updated Office Room Size Updated

SHEET TITLE:

GENERAL DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

250

DATE:

FEB 2017

FILE NO.

SCALE:

N.T.S.

V10

SHEET NO:

D2