13817 62 ave

Page 1

25' [7.62m] 3068

6'-9" [2.06m]

DN

MUHAMMAD SALEEM PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

CLIENT:

6' [1.83m] 67'-2" [20.48m]

33'-6" [10.20m]

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

25'-1" [7.63m]

UDC DESIGN CENTER LTD BUILDING - INTERIOR DESIGNERS

UP

UP

SHEET TITLE:

19'-10" [6.03m]

SITE PLAN

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

1/8"=1'-0"

DEC. 2016

B.M.

G.S.B.

V01

FILE NO.

247

PROJECT NO.

SHEET NO:

A

1/6


SPECIFICATIONS AND GENERAL NOTES:

48' 26'-8"

21'-4"

EXTERIOR BUILDING FINISH MATERIALS:

1" 8'-102

1. ROOF FINISH: ASPHALT SHINGLE

1" 4'-82

7'-9"

1" 6'-72

8'-5"

1" 11'-72

2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE 3. EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

7'-1"

7'-1"

14'-2"

9'-3" Window Well Kit Window Well Kit

4'-11"

3030RS 6026RS

12'-4" 6'-2"

1" 3'-62

5'-4"

1" 3'-102

8'-10"

S

1" 3'-62

5'-4"

4'-5"

Inter Connected Door & Frame must have 20 min. fire rated CW self closing

A A1 2668

2668

3'-10"

2668

9'-2"

S

2668

UP 15R @ 7 1/2" 2'-3"

3968

EXTENT OF SUITE30 MIN. FIRE RATED FOR WALLS AND CLG.

2668

5'-5"

2668

3968

A A1

2668 5068

2668

ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.

2'-11"

S

2468

2626RS

4'-5"

2668

2668

5'-6"

2668

S

11'-2" 5'-8"

NOTES FOR ROOF SPACE VENTILATION

Window Well Kit

6026RS

21068

1. 2.

UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.

3. 4. 5. 6. 7.

PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. LEGEND: PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.

CS

WIN. - CASEMENT

13'-6"

2668 2'-6" WIDTH x 6'-8" HEIGHT 2668

ALL DOORS ARE HOLLOW CORE DOORS, OTHERWISE NOTED RS / LS WIN. - SLIDE TO RIGHT/LEFT

NOTE: WALL FOOTING SIZE - 22"x8": PROVIDE 2-15M LONGITUDINAL @3" CLEAR COVER FROM BOTTOM FOUNDATION WALL - 8" PROVIDE 15M@ 16" o.c. EACH WAY C/W 1.5" CLEAR COVER FROM INSIDE FACE OF WALL F1 - 36" x 36" x 10" CONC. PAD FOOTING 3-15M EACH WAY AT 3" CLEAR COVER FROM BOTTOM

CLIENT:

FX

WIN. - FIXED

SG

SAFETY GLASS - WINDOW

HC

HOLLOW CORE - DOOR

SCW

SOLID CORE W/ WEATHER SEAL - DOOR

WB

WASH BASIN

WC

WATER CLOSET

F

OVERHEAD EXHAUST FAN

3068scw

S

ST

INTERCONNECTED HARDWIRED SMOKE DETECTORS WITH A BATTERY BACKUP SMOKE ALARM & CARBON MONOXIDE (CO) ALARM SOLAR TUBES FOR DAYLIGHT ILLUMINATION AS PER THE MANU. SPECS.

NOTE: ALL LINTELS < 6'-0" LENGTH, SHALL BE 2 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS

20'

ALL LINTELS > 6'-0" LENGTH, SHALL BE 3 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

CO

SOLID CORE DOOR, W/WEATHER STRIPPING

14'-5"

13'-7"

48'

SHEET TITLE:

BASEMENT FLOOR

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

DEC. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A

2/6

60'

2668

6'-2"

1" 1'-112 4'-6"

2626RS

Window Well Kit

3'

3'

INSULATION: PRODUCTS: EXTRUDED POLYSTYRENE: STANDARD CGSB51-GP-20M,TYPE 4. R: 5 PER INCH, RICHNESS: AS REQUIRED TO MEET P VALUE, LOCATION: FOUNDATION INSULATION. EXPANDED POLYSTYRENE: STANDARD: CGB51-GP-20M, TYPE 2, R: 4 PER INCH. THICKNESS: AS REQUIRED TO MEET R VALUE. LOCATION: CAVITY WALLS. BATT INSULATION: STANDARD: CSA A101-M83, TYPE 1. R VALUE: 19 . LOCATION WITHIN WOOD STUD WALLS, AND R 38 WITHIN CEILING. EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT USE CHIPPED OR CRACKED INSULATION BOARDS. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS. INSTALL INSULATION IN CONTINUOS CONTACT WITH INTERIOR SHEATING. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.

SECTION 07300

1" 5'-112

6'-11"

10'-6"

SECTION 07200

9'-5"

1" 7'-02

FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.

EXTENT OF SUITE30 MIN. FIRE RATED FOR WALLS AND CLG.

Window Well Kit

LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF

AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.

1" 4'-82

ROUGH CARPENTRY

FIRE RATED, SOLID CORE, WEATHER STRIPPED, SELF CLOSING DOOR

4'-9"

SECTION 06100

3068

SECTION 07270

5'-4"

12 - DWELLING SECURITY AS PER # 9.6.8 13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.

3068

1" 5'-22

11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN.

6040RS

5'-10"

9- ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. 10- PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING.

6040RS

13'-4"

CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS

1" 14'-92

WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4.

UP

1" 11'-02

78-

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

123456-

VAPOR BARRIER / VAPOR RETARDER PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.

20'-10"

GENERAL NOTES

SECTION 07200

60'

4. WINDOW TRIMS: HARDITRIM 5. SOFFITS: VENTED HARDISOFFIT


48' 25'-8" 1" 4'-62

1" 1'-112

5'-6"

1" 47'-102

22'-4"

3'-2"

1" 3'-52

6'-10"

1" 3'-52

3'

2'-1"

15'-8"

14'

8'-4"

1" 4'-92

1" 10'-102

1" 3'-32

1" 2'-42

1" 15'-62

8'-4" 2'-8"

1" 2'-42

2'-8"

1" 3'-32

1" 10'-102

1" 4'-92

27'-5" 27'-5"

3040RS

3040RS

3068

6040RS

5'

5'

8'-2"

8'-8"

Elongated Toilet

2668 2668

3010RS

2668

3030RS

6'-7"

6040RS

5'-1"

2668 8'-4"

31'-6"

8'-4" 6'-11"

Barrier Free Corner Shower

1" 2'-92

3010RS

1" 6'-22

3010RS

7'-10"

DN 16R @ 7 1/2"

Drain

A A1

Section A-A

1" 8'-72

S

15'-6"

7'-11"

2668 21068

3'-5"

2620RS

7'-8"

A A1

6'-10"

UP 16R @ 7 1/2"

1" 7'-02

A A1

S

21068

3'-8"

5'-4"

21068 1" 2'-32

3030RS

46'-7"

1" 1'-82

1" 5'-82

7'-10"

4'-7"

39'-4"

1" 5'-42

2668

21068

Elongated Toilet

4'-3"

Elongated Toilet

3030RS

21068

1" 10'-72

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

2668

5'-1"

21068 6'-5"

S CO

2668

8040RS

31'

16'

3010RS

16'

16'

S

1" 2'-22

S

2668

21068

3'

2020FX 3'

3'-9"

3030RS

7'-10"

3068

1" 2'-22

16'-8" 1" 8'-82

3'-9"

2020FX

6080

9977FX

6040RS

8'-6"

DN 4R @ 7"

3068

Electric Range [30W]

1" 10'-92

2020FX

1" 11'-62

8068

2668

3030RS 1" 5'-52

8'

11'-2"

1" 2'-62

21068

15'-8"

30'-7"

60'

2668

21068

DRYER

8470TC

1" 6'-82

6090

3030RS

21'

DN 4R @ 7"

1'-8"

4'-11"

4'-11"

1" 2'-12

1" 5'-32 12'

5'-4"

2'-4"

1" 7'-32

7'-8"

1" 7'-52 1" 13'-62

14'-9" 48'

12'-6"

BUILDING - INTERIOR DESIGNERS

7'-10"

3030RS

7'-6"

21068

5040RS

1" 10'-82

Tub-Shower 2

Washer

UDC DESIGN CENTER LTD

5068

1" 3'-12

3040RS

3010RS

5068

9'-6"

3040RS

1" 3'-82

3040RS

1" 2'-72

3040RS

6'-6"

1" 6'-112

1" 6'-112

DN 4R @ 7"

16080 7'-5"

7' 20'

14'-5"

13'-7"

48'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

SHEET TITLE:

M AIN AND UPPER FLOOR

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

DEC. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A

3/6


3'-614" [1.07m]

ROOF RIDGE LVL. 49.40

1

3'-618" [1.07m]

MEAN ROOF LVL. 48.33

12 4

U/S CEILING LVL. 47.26

2 2020FX

2020FX

2020FX

LIST OF MATERIALS

7'-113 4" [2.43m]

9970FX

5

6' DIA.

12 2

3

12 2

8

9'-214" [2.80m]

2.

BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3.

1 x 8 ON 2" X 10" FASCIA BOARD

4.

1" X 4" WOODEN TRIM

5.

STUCCO

6.

ALUMINUM FRAMED WINDOW AND PATIO DOOR

7.

WOODEN EXTERIOR DOOR

6090 6080

6

8470TC

8.

STONE

9.

CEDAR SHAKE SIDING

7

1" 6'-92

9'-13 8" [2.78m]

MAIN FL. LVL. 42.03

29'-6" [8.99m]

4

AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25

FRONT ELEVATION SCALE 1/4" = 1'-0"

ROOF RIDGE LVL. 49.40

3'-614" [1.07m]

1" [0.02m]

3'-618" [1.07m]

MEAN ROOF LVL. 48.33

12 4

3010RS

7'-113 4" [2.43m]

U/S CEILING LVL. 47.26

3

3010RS

3

3010RS

3

8040RS 32

RIGHT ELEVATION

MAIN FL. LVL. 42.03

9'-214" [2.80m]

5040RS 20

9'-13 8" [2.78m]

TOTAL AREA: 976.82 SQ. FT. [90.75 m2] DISTANCE TO PROPERTY LINE: 6'-9" (2.06 M) ≈ 4.0M MAX. ALLOWABLE UNPROTECTED AREA @ 18.0% = 175.83 SQ. FT. PROPOSED UNPROTECTED AREA: = 100 SQ. FT

29'-6" [8.99m]

SECOND FLOOR LVL. 44.83

6026RS

6026RS 15

15

3030RS 9

AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25 1" [0.02m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

4

4

16080

ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK

12

12

SECOND FLOOR LVL. 44.83

1.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

RIGHT ELEVATION SCALE 1/4" = 1'-0"

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

SHEET TITLE:

FRONT & RIGHT ELEVATION

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

DEC. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A

4/6


3'-614" [1.07m]

ROOF RIDGE LVL. 49.40

3'-618" [1.07m]

MEAN ROOF LVL. 48.33

6040RS

3040RS

3040RS

6040RS

3068 3068

2668

9'-214" [2.80m]

3040RS

3040RS

5068

3040RS

3040RS

5068

9'-13 8" [2.78m]

MAIN FL. LVL. 42.03

29'-6" [8.99m]

SECOND FLOOR LVL. 44.83

AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25

REAR ELEVATION

ROOF RIDGE LVL. 49.40

SCALE 1/4" = 1'-0"

3'-614" [1.07m]

1" [0.02m]

3'-618" [1.07m]

MEAN ROOF LVL. 48.33

3010RS

7'-113 4" [2.43m]

U/S CEILING LVL. 47.26

3

3010RS

3

3010RS

3 2620RS

5

3030RS

3030RS 9

9

LEFT ELEVATION

MAIN FL. LVL. 42.03

LEFT ELEVATION

9'-214" [2.80m]

3030RS 9

3030RS 9

3030RS

3030RS 9

9

9

3068

2626RS

2626RS 6.25

6.25

AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25

SCALE 1/4" = 1'-0"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

3030RS

9'-13 8" [2.78m]

TOTAL AREA: 1113.06 SQ. FT. [103.41 m2] DISTANCE TO PROPERTY LINE: 6'-0" (1.83 M) ≈ 2.0M MAX. ALLOWABLE UNPROTECTED AREA @ 8.0% = 90 SQ. FT. PROPOSED UNPROTECTED AREA: 8.0% = 89.5 SQ. FT

29'-6" [8.99m]

SECOND FLOOR LVL. 44.83

CLIENT:

1" [0.02m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

7'-113 4" [2.43m]

U/S CEILING LVL. 47.26

2 : 12

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

SHEET TITLE:

REAR AND LEFT ELEVATION

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

MAY. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A

5/6


3'-614" [1.07m]

ROOF RIDGE LVL. 49.40 SUPPORTED WALL (10M BAR)

LESS THAN 7'-6"

0"

0"

7'-6" TO 8'-0"

18"

20"

8'-1" TO 9'-0"

14"

20"

9'-1" TO 10'-0"

12"

20"

MEAN ROOF LVL. 48.33 EXTERIOR WALL CONSTRUCTION 5

NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER

3'-618" [1.07m]

B

U/S CEILING LVL. 47.26

8"

ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.) TYPICAL FLOOR CONSTRUCTION

2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE

212" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED

24"

15M @ 15" o.c.

4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS

ON PLAN

AS NOTED

8"

4" CONC. SLAB 6 MIL VAPOUR BARRIER

AS PER PLAN

2" RIGID INSULATION (N.I.C.)

MAIN FL. LVL. 42.03

21068

21068

3040RS

3040RS

DN 16R @ 7 1/2"

3040RS

CONCRETE FOOTING AS PER PLAN

AS NOTED ON PLAN

AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25

TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH

4

21068

112" CONC. TOPPING

AIL R D

R UA G H

IG

H 36"

21068

7

3

UP 15R @ 7 1/2"

3 3068

3068

6 DRAIN TILE 2-15M CONTINUOUS

1" [0.02m]

INTERNAL WALL FOUNDATION

112" CONC. TOPPING

1" 2

7

2-15M CONT.

SUPPORTED WALL SECTION

2668

5

9'-13 8" [2.78m]

4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL

8" REINFORCED CONCRETE FOUNDATION WALL

15# FELT SIMPSON POST CAP OR EQUIVALENT (N.I.C)

29'-6" [8.99m]

APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13

POST AS PER PLAN

3" CLR.

HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM)

SIMPSON POST CAP OR EQUIVALENT (N.I.C)

AS PER PLAN

MAX. COVER 2"

21068

2

4

BEAM AS PER PLAN

NET BACKFILL HEIGHT

VERTICAL STEEL = 'A' (ALTERNATE HOOKS)

1

5

SECOND FLOOR LVL. 44.83

MAIN FL. CONSTRUCTION

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD

MAIN FLOOR

SECTION A1

A

1

FLOOR JOIST

6" MIN.

2" MIN.

8" MIN. CONC. LINTEL

WINDOW OPENING

2" MIN.

2 - 15M (TYP.) EXTEND 12" BEYOND OPENING E/S.

2 - 15M BARS FULL HEIGHT @ E/S. WINDOW JAMB

SECTIONAL DETAILS AND SPECIFICATIONS:

SCALE 1/4" = 1'-0"

1'-0"

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

GARAGE SLAB OR FINISHED GRADE

12 4

2

7'-113 4" [2.43m]

A

9'-214" [2.80m]

NET BACKFILL HT.

1

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

5

8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)

ROOF:

5

- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

F.R.R WALL DETAIL

2

EAVES:

- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION - 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

6

CONCRETE WALL

3

FND. WALL OPENING DETAIL

4

SCALE: NTS

OUT 12"

NOTCH TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS

5

8" TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL

INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

SUBFLOOR

-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD

DETAIL AT 'A'

7

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

30 MIN. F.R.R. ASSEMBLY DETAIL

MAIN AND UPPER FLOOR (1 hr FRR):

INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

F.R.R. CEILING DETAIL UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

SHEET TITLE:

SECTION AND DETAILS

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

DEC. 2016

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A

6/6


BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

∙

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

SHEET TITLE:

ENERGY DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

DEC. 2016

FILE NO.

SCALE:

N.T.S.

V01

SHEET NO:

A


GRID

GRID

HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

EXTERIOR

4" FLANGE 6

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER 2X10 FLOOR JOISTS

4.06

23.03

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

3.99

22.61

0.68

4.11

23.29

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

SEPERATION AIR SPACE

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

EXTERIOR STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

INTERIOR

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)

SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

W-1

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

CEMENT OR ACRYLIC STUCCO PARGING

INSECT SCREEN CEMENT OR ACRYLIC STUCCO PARGING

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in.

1/2"

2" MIN.

FILTER CLOTH

VENTED ALUMINUM SOFFIT PANELS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06 8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

1" 2

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

DRYWALL FINISH

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

MUHAMMAD SALEEM

PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:

SHEET TITLE:

GENERAL DETAIL

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12

1" 2

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

ROD AND SEALANT

4" FLANGE

25.4mm (1")

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

GRID

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

247

DATE:

DEC. 2016

FILE NO.

SCALE:

N.T.S.

V01

SHEET NO:

b


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.