25' [7.62m] 3068
6'-9" [2.06m]
DN
MUHAMMAD SALEEM PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
CLIENT:
6' [1.83m] 67'-2" [20.48m]
33'-6" [10.20m]
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
25'-1" [7.63m]
UDC DESIGN CENTER LTD BUILDING - INTERIOR DESIGNERS
UP
UP
SHEET TITLE:
19'-10" [6.03m]
SITE PLAN
SCALE:
DATE:
CHECKED BY:
DRAWN BY:
1/8"=1'-0"
DEC. 2016
B.M.
G.S.B.
V01
FILE NO.
247
PROJECT NO.
SHEET NO:
A
1/6
SPECIFICATIONS AND GENERAL NOTES:
48' 26'-8"
21'-4"
EXTERIOR BUILDING FINISH MATERIALS:
1" 8'-102
1. ROOF FINISH: ASPHALT SHINGLE
1" 4'-82
7'-9"
1" 6'-72
8'-5"
1" 11'-72
2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE 3. EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
7'-1"
7'-1"
14'-2"
9'-3" Window Well Kit Window Well Kit
4'-11"
3030RS 6026RS
12'-4" 6'-2"
1" 3'-62
5'-4"
1" 3'-102
8'-10"
S
1" 3'-62
5'-4"
4'-5"
Inter Connected Door & Frame must have 20 min. fire rated CW self closing
A A1 2668
2668
3'-10"
2668
9'-2"
S
2668
UP 15R @ 7 1/2" 2'-3"
3968
EXTENT OF SUITE30 MIN. FIRE RATED FOR WALLS AND CLG.
2668
5'-5"
2668
3968
A A1
2668 5068
2668
ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.
2'-11"
S
2468
2626RS
4'-5"
2668
2668
5'-6"
2668
S
11'-2" 5'-8"
NOTES FOR ROOF SPACE VENTILATION
Window Well Kit
6026RS
21068
1. 2.
UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.
3. 4. 5. 6. 7.
PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. LEGEND: PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.
CS
WIN. - CASEMENT
13'-6"
2668 2'-6" WIDTH x 6'-8" HEIGHT 2668
ALL DOORS ARE HOLLOW CORE DOORS, OTHERWISE NOTED RS / LS WIN. - SLIDE TO RIGHT/LEFT
NOTE: WALL FOOTING SIZE - 22"x8": PROVIDE 2-15M LONGITUDINAL @3" CLEAR COVER FROM BOTTOM FOUNDATION WALL - 8" PROVIDE 15M@ 16" o.c. EACH WAY C/W 1.5" CLEAR COVER FROM INSIDE FACE OF WALL F1 - 36" x 36" x 10" CONC. PAD FOOTING 3-15M EACH WAY AT 3" CLEAR COVER FROM BOTTOM
CLIENT:
FX
WIN. - FIXED
SG
SAFETY GLASS - WINDOW
HC
HOLLOW CORE - DOOR
SCW
SOLID CORE W/ WEATHER SEAL - DOOR
WB
WASH BASIN
WC
WATER CLOSET
F
OVERHEAD EXHAUST FAN
3068scw
S
ST
INTERCONNECTED HARDWIRED SMOKE DETECTORS WITH A BATTERY BACKUP SMOKE ALARM & CARBON MONOXIDE (CO) ALARM SOLAR TUBES FOR DAYLIGHT ILLUMINATION AS PER THE MANU. SPECS.
NOTE: ALL LINTELS < 6'-0" LENGTH, SHALL BE 2 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS
20'
ALL LINTELS > 6'-0" LENGTH, SHALL BE 3 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
CO
SOLID CORE DOOR, W/WEATHER STRIPPING
14'-5"
13'-7"
48'
SHEET TITLE:
BASEMENT FLOOR
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
DEC. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
2/6
60'
2668
6'-2"
1" 1'-112 4'-6"
2626RS
Window Well Kit
3'
3'
INSULATION: PRODUCTS: EXTRUDED POLYSTYRENE: STANDARD CGSB51-GP-20M,TYPE 4. R: 5 PER INCH, RICHNESS: AS REQUIRED TO MEET P VALUE, LOCATION: FOUNDATION INSULATION. EXPANDED POLYSTYRENE: STANDARD: CGB51-GP-20M, TYPE 2, R: 4 PER INCH. THICKNESS: AS REQUIRED TO MEET R VALUE. LOCATION: CAVITY WALLS. BATT INSULATION: STANDARD: CSA A101-M83, TYPE 1. R VALUE: 19 . LOCATION WITHIN WOOD STUD WALLS, AND R 38 WITHIN CEILING. EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT USE CHIPPED OR CRACKED INSULATION BOARDS. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS. INSTALL INSULATION IN CONTINUOS CONTACT WITH INTERIOR SHEATING. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.
SECTION 07300
1" 5'-112
6'-11"
10'-6"
SECTION 07200
9'-5"
1" 7'-02
FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.
EXTENT OF SUITE30 MIN. FIRE RATED FOR WALLS AND CLG.
Window Well Kit
LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF
AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.
1" 4'-82
ROUGH CARPENTRY
FIRE RATED, SOLID CORE, WEATHER STRIPPED, SELF CLOSING DOOR
4'-9"
SECTION 06100
3068
SECTION 07270
5'-4"
12 - DWELLING SECURITY AS PER # 9.6.8 13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.
3068
1" 5'-22
11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN.
6040RS
5'-10"
9- ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. 10- PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING.
6040RS
13'-4"
CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS
1" 14'-92
WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4.
UP
1" 11'-02
78-
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
123456-
VAPOR BARRIER / VAPOR RETARDER PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.
20'-10"
GENERAL NOTES
SECTION 07200
60'
4. WINDOW TRIMS: HARDITRIM 5. SOFFITS: VENTED HARDISOFFIT
48' 25'-8" 1" 4'-62
1" 1'-112
5'-6"
1" 47'-102
22'-4"
3'-2"
1" 3'-52
6'-10"
1" 3'-52
3'
2'-1"
15'-8"
14'
8'-4"
1" 4'-92
1" 10'-102
1" 3'-32
1" 2'-42
1" 15'-62
8'-4" 2'-8"
1" 2'-42
2'-8"
1" 3'-32
1" 10'-102
1" 4'-92
27'-5" 27'-5"
3040RS
3040RS
3068
6040RS
5'
5'
8'-2"
8'-8"
Elongated Toilet
2668 2668
3010RS
2668
3030RS
6'-7"
6040RS
5'-1"
2668 8'-4"
31'-6"
8'-4" 6'-11"
Barrier Free Corner Shower
1" 2'-92
3010RS
1" 6'-22
3010RS
7'-10"
DN 16R @ 7 1/2"
Drain
A A1
Section A-A
1" 8'-72
S
15'-6"
7'-11"
2668 21068
3'-5"
2620RS
7'-8"
A A1
6'-10"
UP 16R @ 7 1/2"
1" 7'-02
A A1
S
21068
3'-8"
5'-4"
21068 1" 2'-32
3030RS
46'-7"
1" 1'-82
1" 5'-82
7'-10"
4'-7"
39'-4"
1" 5'-42
2668
21068
Elongated Toilet
4'-3"
Elongated Toilet
3030RS
21068
1" 10'-72
SMOKE ALARM & CARBON MONOXIDE (CO) ALARM
2668
5'-1"
21068 6'-5"
S CO
2668
8040RS
31'
16'
3010RS
16'
16'
S
1" 2'-22
S
2668
21068
3'
2020FX 3'
3'-9"
3030RS
7'-10"
3068
1" 2'-22
16'-8" 1" 8'-82
3'-9"
2020FX
6080
9977FX
6040RS
8'-6"
DN 4R @ 7"
3068
Electric Range [30W]
1" 10'-92
2020FX
1" 11'-62
8068
2668
3030RS 1" 5'-52
8'
11'-2"
1" 2'-62
21068
15'-8"
30'-7"
60'
2668
21068
DRYER
8470TC
1" 6'-82
6090
3030RS
21'
DN 4R @ 7"
1'-8"
4'-11"
4'-11"
1" 2'-12
1" 5'-32 12'
5'-4"
2'-4"
1" 7'-32
7'-8"
1" 7'-52 1" 13'-62
14'-9" 48'
12'-6"
BUILDING - INTERIOR DESIGNERS
7'-10"
3030RS
7'-6"
21068
5040RS
1" 10'-82
Tub-Shower 2
Washer
UDC DESIGN CENTER LTD
5068
1" 3'-12
3040RS
3010RS
5068
9'-6"
3040RS
1" 3'-82
3040RS
1" 2'-72
3040RS
6'-6"
1" 6'-112
1" 6'-112
DN 4R @ 7"
16080 7'-5"
7' 20'
14'-5"
13'-7"
48'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
SHEET TITLE:
M AIN AND UPPER FLOOR
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
DEC. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
3/6
3'-614" [1.07m]
ROOF RIDGE LVL. 49.40
1
3'-618" [1.07m]
MEAN ROOF LVL. 48.33
12 4
U/S CEILING LVL. 47.26
2 2020FX
2020FX
2020FX
LIST OF MATERIALS
7'-113 4" [2.43m]
9970FX
5
6' DIA.
12 2
3
12 2
8
9'-214" [2.80m]
2.
BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3.
1 x 8 ON 2" X 10" FASCIA BOARD
4.
1" X 4" WOODEN TRIM
5.
STUCCO
6.
ALUMINUM FRAMED WINDOW AND PATIO DOOR
7.
WOODEN EXTERIOR DOOR
6090 6080
6
8470TC
8.
STONE
9.
CEDAR SHAKE SIDING
7
1" 6'-92
9'-13 8" [2.78m]
MAIN FL. LVL. 42.03
29'-6" [8.99m]
4
AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25
FRONT ELEVATION SCALE 1/4" = 1'-0"
ROOF RIDGE LVL. 49.40
3'-614" [1.07m]
1" [0.02m]
3'-618" [1.07m]
MEAN ROOF LVL. 48.33
12 4
3010RS
7'-113 4" [2.43m]
U/S CEILING LVL. 47.26
3
3010RS
3
3010RS
3
8040RS 32
RIGHT ELEVATION
MAIN FL. LVL. 42.03
9'-214" [2.80m]
5040RS 20
9'-13 8" [2.78m]
TOTAL AREA: 976.82 SQ. FT. [90.75 m2] DISTANCE TO PROPERTY LINE: 6'-9" (2.06 M) â&#x2030;&#x2C6; 4.0M MAX. ALLOWABLE UNPROTECTED AREA @ 18.0% = 175.83 SQ. FT. PROPOSED UNPROTECTED AREA: = 100 SQ. FT
29'-6" [8.99m]
SECOND FLOOR LVL. 44.83
6026RS
6026RS 15
15
3030RS 9
AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25 1" [0.02m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
4
4
16080
ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK
12
12
SECOND FLOOR LVL. 44.83
1.
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
RIGHT ELEVATION SCALE 1/4" = 1'-0"
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
SHEET TITLE:
FRONT & RIGHT ELEVATION
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
DEC. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
4/6
3'-614" [1.07m]
ROOF RIDGE LVL. 49.40
3'-618" [1.07m]
MEAN ROOF LVL. 48.33
6040RS
3040RS
3040RS
6040RS
3068 3068
2668
9'-214" [2.80m]
3040RS
3040RS
5068
3040RS
3040RS
5068
9'-13 8" [2.78m]
MAIN FL. LVL. 42.03
29'-6" [8.99m]
SECOND FLOOR LVL. 44.83
AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25
REAR ELEVATION
ROOF RIDGE LVL. 49.40
SCALE 1/4" = 1'-0"
3'-614" [1.07m]
1" [0.02m]
3'-618" [1.07m]
MEAN ROOF LVL. 48.33
3010RS
7'-113 4" [2.43m]
U/S CEILING LVL. 47.26
3
3010RS
3
3010RS
3 2620RS
5
3030RS
3030RS 9
9
LEFT ELEVATION
MAIN FL. LVL. 42.03
LEFT ELEVATION
9'-214" [2.80m]
3030RS 9
3030RS 9
3030RS
3030RS 9
9
9
3068
2626RS
2626RS 6.25
6.25
AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25
SCALE 1/4" = 1'-0"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
3030RS
9'-13 8" [2.78m]
TOTAL AREA: 1113.06 SQ. FT. [103.41 m2] DISTANCE TO PROPERTY LINE: 6'-0" (1.83 M) â&#x2030;&#x2C6; 2.0M MAX. ALLOWABLE UNPROTECTED AREA @ 8.0% = 90 SQ. FT. PROPOSED UNPROTECTED AREA: 8.0% = 89.5 SQ. FT
29'-6" [8.99m]
SECOND FLOOR LVL. 44.83
CLIENT:
1" [0.02m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
7'-113 4" [2.43m]
U/S CEILING LVL. 47.26
2 : 12
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
SHEET TITLE:
REAR AND LEFT ELEVATION
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
MAY. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
5/6
3'-614" [1.07m]
ROOF RIDGE LVL. 49.40 SUPPORTED WALL (10M BAR)
LESS THAN 7'-6"
0"
0"
7'-6" TO 8'-0"
18"
20"
8'-1" TO 9'-0"
14"
20"
9'-1" TO 10'-0"
12"
20"
MEAN ROOF LVL. 48.33 EXTERIOR WALL CONSTRUCTION 5
NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER
3'-618" [1.07m]
B
U/S CEILING LVL. 47.26
8"
ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.) TYPICAL FLOOR CONSTRUCTION
2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE
212" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED
24"
15M @ 15" o.c.
4"Ã&#x2DC; PERIMETER DRAIN TILE WITH DRAIN ROCKS
ON PLAN
AS NOTED
8"
4" CONC. SLAB 6 MIL VAPOUR BARRIER
AS PER PLAN
2" RIGID INSULATION (N.I.C.)
MAIN FL. LVL. 42.03
21068
21068
3040RS
3040RS
DN 16R @ 7 1/2"
3040RS
CONCRETE FOOTING AS PER PLAN
AS NOTED ON PLAN
AVE. GRADE. LVL. 39.27 BSMT. FL. LVL./MBE 39.25
TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH
4
21068
112" CONC. TOPPING
AIL R D
R UA G H
IG
H 36"
21068
7
3
UP 15R @ 7 1/2"
3 3068
3068
6 DRAIN TILE 2-15M CONTINUOUS
1" [0.02m]
INTERNAL WALL FOUNDATION
112" CONC. TOPPING
1" 2
7
2-15M CONT.
SUPPORTED WALL SECTION
2668
5
9'-13 8" [2.78m]
4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL
8" REINFORCED CONCRETE FOUNDATION WALL
15# FELT SIMPSON POST CAP OR EQUIVALENT (N.I.C)
29'-6" [8.99m]
APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13
POST AS PER PLAN
3" CLR.
HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM)
SIMPSON POST CAP OR EQUIVALENT (N.I.C)
AS PER PLAN
MAX. COVER 2"
21068
2
4
BEAM AS PER PLAN
NET BACKFILL HEIGHT
VERTICAL STEEL = 'A' (ALTERNATE HOOKS)
1
5
SECOND FLOOR LVL. 44.83
MAIN FL. CONSTRUCTION
F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD
MAIN FLOOR
SECTION A1
A
1
FLOOR JOIST
6" MIN.
2" MIN.
8" MIN. CONC. LINTEL
WINDOW OPENING
2" MIN.
2 - 15M (TYP.) EXTEND 12" BEYOND OPENING E/S.
2 - 15M BARS FULL HEIGHT @ E/S. WINDOW JAMB
SECTIONAL DETAILS AND SPECIFICATIONS:
SCALE 1/4" = 1'-0"
1'-0"
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
GARAGE SLAB OR FINISHED GRADE
12 4
2
7'-113 4" [2.43m]
A
9'-214" [2.80m]
NET BACKFILL HT.
1
DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD
5
8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)
ROOF:
5
- ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD
F.R.R WALL DETAIL
2
EAVES:
- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION - 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)
6
CONCRETE WALL
3
FND. WALL OPENING DETAIL
4
SCALE: NTS
OUT 12"
NOTCH TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS
5
8" TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL
INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY
SUBFLOOR
-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD
DETAIL AT 'A'
7
FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE
EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD
BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL
- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
30 MIN. F.R.R. ASSEMBLY DETAIL
MAIN AND UPPER FLOOR (1 hr FRR):
INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL
F.R.R. CEILING DETAIL UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
SHEET TITLE:
SECTION AND DETAILS
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
DEC. 2016
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
6/6
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
â&#x2C6;&#x2122;
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
SHEET TITLE:
ENERGY DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
DEC. 2016
FILE NO.
SCALE:
N.T.S.
V01
SHEET NO:
A
GRID
GRID
HEADER
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING
MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
4" ADHERED FLASHING MEMBRANE
INTERIOR
EXTERIOR
4" FLANGE 6
100 mm (4")
FLOOR FINISH ON CONCRETE TOPPING
SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN
MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)
2"CONTINUOUS FLANGE AT PERIMETER OF HOOD
STUD @ 16" O.C
2"
2
SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
1 MIN 2"
BLDG. PAPER 2X10 FLOOR JOISTS
4.06
23.03
SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)
3.99
22.61
0.68
4.11
23.29
ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM
RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12
R 0.44 0.00 0.77 50.0 0.00 0.45 0.68
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
9.21
50.34
FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE
RSI 0.03 0.12 0.00 0.15 4.99 0.00
R 0.17 0.68 0.00 0.83 28.00 0.00
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
5.29
29.68
TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME
USI
U
1.4
0.246
SEPERATION AIR SPACE
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME
VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
1.5" SILL PLATE
EXTERIOR STUCCO CLADDING
- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )
INTERIOR
AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION
THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)
SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)
FLASHING & COUNTER FLASHING
SEALANT OR GASKET (A.B.)
ASPHALT IMPREGNATED PAPER
INSECT SCREEN - NO DAMPERS
EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD
GRID
1/2″ (12.7 MM) PLYWOOD SHEATHING
2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT
POLYETHYLENE VAPOR BARRIER
ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)
1/2″ (12.7 MM) GYPSUM BOARD
MIN. 2% SLOPE TO DRAIN
2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING
SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL
INSULATION GUARD
POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)
EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
GASKET (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
W-1
LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)
SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING
SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING
INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)
HOUSEWRAP AT HEADER (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD
BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE
25mm (1")
ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)
CEMENT OR ACRYLIC STUCCO PARGING
INSECT SCREEN CEMENT OR ACRYLIC STUCCO PARGING
SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS
DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
8" CONC. FOUNDATION WALL
FINISHED GRADE
4" EXTRUDED POLYSTYRENE R-5/in.
1/2"
2" MIN.
FILTER CLOTH
VENTED ALUMINUM SOFFIT PANELS
FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06 8" MINIMUM
SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL HOUSEWRAP (A.B.) TO FRAMING
CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL
ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER
INTERIOR
1" 2
REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.
DRYWALL FINISH
WOOD FRAMING (STUDS OR STRAPPING)
W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
MUHAMMAD SALEEM
PROJECT: CIVIC ADDRESS: LOT 1, 13817 62 AVE SURREY, BC LEGAL DESCRIPTION:
SHEET TITLE:
GENERAL DETAIL
RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12
1" 2
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
1 MIN.
ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW
SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
2a
2 SEALANT OR GASKET (A.B.)
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
12mm (1/2")
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)
1X2 STRAPPING
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
ROD AND SEALANT
4" FLANGE
25.4mm (1")
RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12
WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
SHEATHING PAPER TO LAP METAL FLASHING
ROD AND SEALANT 1
WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
4"
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI / R VALUE CALCULATIONS FOR ASSEMBLIES
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
GRID
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
247
DATE:
DEC. 2016
FILE NO.
SCALE:
N.T.S.
V01
SHEET NO:
b