15493 18 ave

Page 1

25'-2" [7.68m]

77' [23.47m] BLDG DEPTH

48'-10" [14.89m]

27'-1" [8.26m] REAR SETBACK

9'-8" [2.95m]

BUILDING - INTERIOR DESIGNERS

SUMP

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

30'-11" [9.42m]

48'-1" [14.64m]

6' [1.83m] SIDE SETBACK

18' [5.49m] FRONT SETBACK

UDC DESIGN CENTER LTD

6'-83 4" [2.05m] SIDE SETBACK

to be removed

SHEET TITLE:

Site Plan

to be removed

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

1/8" = 1'-0"

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A 1/5


40'-6" 24'-5"

16'-1" 4'-7"

11'-10"

8'-0"

3030RS

3'-10" 3'-7"

6'-8"

3080FX

14'-4"

3'-10"

3080FX 3080FX

2668

3030RS

3'-0"

2668

4'-8" 4" 2'-0" 9'-2"

4'-1" 6040RS

2668

Elongated Toilet

5'-1"

2668

5'-1" 2'-8"

4'-6"

7'-10"

10'-5"

3070FX

21'-0"

Dryer (curved) 22" w/ Gas Upflow [22 1/2W28 5/8D] Medium Elec WH

5068

6'-6"

Elongated Toilet

2668

4068

Elevation 5

9'-5"

5'-0"

1468

Tub-Shower 2

5'-6"

5030RS

3016RS

5040RS

6040RS

3068

3030RS

3'-8"

2630RS

A1 A

FIRE RATED, SOLID CORE, WEATHER STRIPPED, SELF CLOSING DOOR

5'-0"

2668 S

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

3070FX

2468

E5

2668

Bottom Mount Refrigerator 3 S CO

5'-6"

3068 Dryer (curved) Apron Front Sink [24 13/16W]

9'-11"

2668

S

3070FX

9'-0"

3068

5'-4"

FIRE RATED WALL

FIRE RATED DOOR

3'-8"

5'-0"

3'-6"

2668

FIRE RATED WALL

3'-8"

31168

3040RS

2668

Electric Range

11'-5"

3068

13'-8"

21'-9"

16080

3'-2"

56'-8"

2668

3040RS

5'-0"

5068

9'-9"

A1 A

53'-0"

3'-8"

2668

6'-5"

35'-8"

9'-5"

DN

UP E6

3068

Elevation 6

LINE OF DECK ABOVE 31'-8"

6068

8'-8"

1'-6"

2668

BUILDING - INTERIOR DESIGNERS

4'-9"

Dishwasher

5"

SMOKE ALARM & CARBON MONOXIDE (CO) ALARM

WH

3068

UDC DESIGN CENTER LTD

7'-8"

4'-8"

3'-1"

3040RS S CO

5'-3"

5'-3"

3'-9"

4'-5"

18'-8"

3'-7"

4'-10"

2'-9" 3'-5"

8'-6"

2'-8"

4'-8"

5'-5"

4'-8" 9'-4"

2'-4"

1'-6" 1'-8" 2'-4"

3'-2"

4'-3"

19'-8" 22'-0"

77'-0"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

main floor plan

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

TOWNSHIP 1 NEW WESTMINSTER SCALE:

V01

SHEET NO:

A 2/5


49'-0" 11'-9"

15'-0"

12'-3"

2668

14'-5"

3068

10'-0"

E6

Elevation 6

3'-9" 2668

2'-9" 13'-6"

Elongated Toilet

4040RS

3'-0"

Tub-Shower 2

4068

4068

Tub-Shower 2

Elongated Toilet

6034RS

2030SH

8'-4"

4'-0"

6'-5"

5'-8"

16'-1"

6031RS

A1 A

2668

5'-8"

2668

5'-8"

A1 A

S

16'-0"

6'-0"

S

2'-6"

3040RS

2668

5068 5068

3040RS

21068

21068

5068

4'-4"

11'-2"

4'-8" 4020RS

2668

17'-3"

2668 S

51'-8"

5068

2668

2'-4"

6'-4"

W

51'-8"

D

BUILDING - INTERIOR DESIGNERS

DN

S

10'-1"

5068

6040RS

13'-4"

2668

24'-6"

2668

UDC DESIGN CENTER LTD

10'-8"

8'-4"

6'-8" 12'-4"

2'-8"

2'-8"

5'-4"

7'-3"

8'-0" 15'-3"

49'-0"

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

uppper floor plan

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A 3/5


ROOF RIDGE LVL. 112.45

ROOF RIDGE LVL. 112.45 6'-67 8" [2.00m]

6'-67 8" [2.00m]

1

MEAN ROOF LVL. 110.45

MEAN ROOF LVL. 110.45

U/S CEILING LVL. 108.45

10 3

U/S CEILING LVL. 108.45

2

9'-03 4" [2.76m]

9'-03 4" [2.76m]

8

8 4020RS 3040RS

6

4030FX

3040RS

10

SECOND FLOOR LVL. 105.69

4

3070FX

3070FX

3080FX

3080FX

3080FX

6040RS

3070FX

2'-87 8" [0.83m]

MAIN FL. LVL. 102.30

6

8

8

MAIN FL. LVL. 102.30

AVE. GRADE. LVL. 101.47

RIGHT ELEVATION TOTAL AREA: 856.6 SQ. FT. = 79.5 SQ.M DISTANCE TO PROPERTY LINE: 6' - 8" = 2M MAX. ALLOWABLE UNPROTECTED AREA @ 9.0% = 77.09 SQ. FT. PROPOSED UNPROTECTED AREA: = 77SQ. FT

3040RS

2'-8 8" [0.83m]

8

7

29'-6" [8.99m]

8

11'-13 8" [3.39m]

29'-6" [8.99m]

10

11'-13 8" [3.39m]

10

SECOND FLOOR LVL. 105.69

AVE. GRADE. LVL. 101.47

RIGHT ELEVATION SCALE:1/4"-1'

FRONT ELEVATION SCALE:1/4"-1' MATERIAL SPECIFICATIONS 1.

ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK

2.

BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3.

1 x 4 OVER 2" X 10" FASCIA BOARD

4.

4" OR 6" WINDOW AND DOOR TRIM

5.

STUCCO

6.

ALUMINUM FRAMED WINDOW AND PATIO DOOR

7.

WOODEN EXTERIOR DOOR

8. STONE 9. CEDAR 10. SHINGLES

6'-67 8" [2.00m]

ROOF RIDGE LVL. 112.45 6'-67 8" [2.00m]

ROOF RIDGE LVL. 112.45

6040RS

9'-03 4" [2.76m]

U/S CEILING LVL. 108.45

9'-03 4" [2.76m]

U/S CEILING LVL. 108.45

4040RS

TOTAL AREA: 1106.5 SQ. FT. [102.80SQ.M] DISTANCE TO PROPERTY LINE: 6' (1.82 M) ≈ 2.0M MAX. ALLOWABLE UNPROTECTED AREA @ 8.0% = 88.52 SQ. FT. PROPOSED UNPROTECTED AREA: 8.0% = 87.5 SQ. FT

MAIN FL. LVL. 102.30

3016RS 3030RS

5030RS 6040RS

2630RS

5040RS

2'-8 8" [0.83m]

3040RS

2'-87 8" [0.83m]

3040RS

7

29'-6" [8.99m] 3030RS

11'-13 8" [3.39m]

3030RS

AVE. GRADE. LVL. 101.47

2'-518" [0.74m]

AVE. GRADE. LVL. 101.47

LEFT ELEVATION

6031RS

6034RS

2030SH

SECOND FLOOR LVL. 105.69 29'-6" [8.99m]

SECOND FLOOR LVL. 105.69

MAIN FL. LVL. 102.30

6'-67 8" [2.00m]

MEAN ROOF LVL. 110.45 6'-67 8" [2.00m]

MEAN ROOF LVL. 110.45

11'-13 8" [3.39m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

6'-67 8" [2.00m]

6'-67 8" [2.00m]

10

REAR ELEVATION

LEFT ELEVATION

SCALE:1/4"-1'

SCALE:1/4"-1'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

ELEVATIONS

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

1/8" = 1'-0"

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A 4/5


6'-67 8" [2.00m]

ROOF RIDGE LVL. 112.45

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

6'-67 8" [2.00m]

MEAN ROOF LVL. 110.45

9'-03 4" [2.76m]

3040RS

TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH 1" 2

2'-87 8" [0.83m]

MAIN FL. LVL. 102.30

11'-13 8" [3.39m]

29'-6" [8.99m]

SECOND FLOOR LVL. 105.69

AVE. GRADE. LVL. 101.47

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

SUPPORTED WALL (10M BAR)

SECTION A-1 SCALE:1/4"-1'

NET BACKFILL HT.

A

B

LESS THAN 7'-6"

0"

0"

7'-6" TO 8'-0"

18"

20"

8'-1" TO 9'-0"

14"

20"

9'-1" TO 10'-0"

12"

20"

5

NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER

ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.)

8"

TYPICAL FLOOR CONSTRUCTION

2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE GARAGE SLAB OR FINISHED GRADE

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

VERTICAL STEEL = 'A' (ALTERNATE HOOKS) MAX. COVER 2" HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM) APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13

NET BACKFILL HEIGHT

2 2" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED

5

8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

NOTCH OUT 21" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS

5

8" TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL

-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (85") TYPE X GYPSUM BOARD

15M @ 15" o.c.

4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS

ON PLAN

8"

DETAIL AT 'A'

1

5

ROOF: - ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

F.R.R WALL DETAIL 2

- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

6

EAVES:

3

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD

F.R.R. CEILING DETAIL

BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

INTERIOR PARTITIONS ( 1 hr FRR): 7

- 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

4

MAIN AND UPPER FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

SUBFLOOR

4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL

8" REINFORCED CONCRETE FOUNDATION WALL

SUPPORTED WALL SECTION

SECTIONAL DETAILS AND SPECIFICATIONS:

FLOOR JOIST

30 MIN. F.R.R. ASSEMBLY DETAIL

1

24"

A

EXTERIOR WALL CONSTRUCTION

AS NOTED

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

U/S CEILING LVL. 108.45

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

2-15M CONT. AS NOTED ON PLAN

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

SECTION AND DETAILS

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A 5/5


6'-67 8" [2.00m]

ROOF RIDGE LVL. 112.45

9'-03 4" [2.76m]

U/S CEILING LVL. 108.45

3040RS

5

11'-13 8" [3.39m]

4 3

5 9'-05 8" [2.76m]

6'-4" [1.93m]

MAIN FL. LVL. 102.30 AVE. GRADE. LVL. 101.47

93 8" [0.24m]

29'-6" [8.99m]

SECOND FLOOR LVL. 105.69

7 TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH 1" 2

7 6

BSMT. FL. LVL. 99.54

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD

SUPPORTED WALL (10M BAR)

SECTION A-1 SCALE:1/4"-1'

NET BACKFILL HT.

A

B

LESS THAN 7'-6"

0"

0"

7'-6" TO 8'-0"

18"

20"

8'-1" TO 9'-0"

14"

20"

9'-1" TO 10'-0"

12"

20"

5

NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER

ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.)

8"

TYPICAL FLOOR CONSTRUCTION

2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE GARAGE SLAB OR FINISHED GRADE

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

VERTICAL STEEL = 'A' (ALTERNATE HOOKS) MAX. COVER 2" HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM) APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13

NET BACKFILL HEIGHT

2 2" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED

5

8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)

W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD

NOTCH OUT 21" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS

5

8" TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL

-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (85") TYPE X GYPSUM BOARD

15M @ 15" o.c.

4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS

ON PLAN

8"

DETAIL AT 'A'

1

5

ROOF: - ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

F.R.R WALL DETAIL 2

- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

6

EAVES:

3

F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD

F.R.R. CEILING DETAIL

BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

INTERIOR PARTITIONS ( 1 hr FRR): 7

- 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

4

MAIN AND UPPER FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

SUBFLOOR

4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL

8" REINFORCED CONCRETE FOUNDATION WALL

SUPPORTED WALL SECTION

SECTIONAL DETAILS AND SPECIFICATIONS:

FLOOR JOIST

30 MIN. F.R.R. ASSEMBLY DETAIL

1

24"

A

EXTERIOR WALL CONSTRUCTION

AS NOTED

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

12 7

6'-67 8" [2.00m]

MEAN ROOF LVL. 110.45

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

2-15M CONT. AS NOTED ON PLAN

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

SECTION AND DETAILS

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A6


BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

∙

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

ENERGY DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

N.T.S.

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A7


GRID

GRID GRID

HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER

4.06

23.03

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

3.99

22.61

0.68

4.11

23.29

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

2X10 FLOOR JOISTS

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

SEPERATION AIR SPACE

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12

1" 2

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

BUILDING - INTERIOR DESIGNERS

EXTERIOR STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED

INTERIOR

( APPLICATION CODE :CGSB -37-GP-55M) SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

W-1

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

2" MIN.

FILTER CLOTH

VENTED ALUMINUM SOFFIT PANELS

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06 DAMP PROOFING / VAP. BARRIER

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in. 1" 2

COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

CEMENT OR ACRYLIC STUCCO PARGING

DRYWALL FINISH

912"

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL

INSECT SCREEN

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

512"

CEMENT OR ACRYLIC STUCCO PARGING

8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

1/2"

UDC DESIGN CENTER LTD

ROD AND SEALANT

4" FLANGE

25.4mm (1")

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4" FLANGE 6

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

EXTERIOR

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT: BUILDER: YARED AFEWORK 604 - 290 - 7272 yared.a@alairhomes.com

DR. OLU

PROJECT: CIVIC ADDRESS:15493 18 AVE SOUTH SURREY, BC LEGAL DESCRIPTION: LOT #9 SECTION 14 DISTRICT PLAN 13376

SHEET TITLE:

GENERAL DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1281

DATE:

JUNE. 2017

FILE NO.

SCALE:

N.T.S.

V01

TOWNSHIP 1 NEW WESTMINSTER

SHEET NO:

A8


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.