13'-112" [4.00m]
] 3m 4.7 CK " [1 BA '-4 ET 48 AR S RE
" '-1 2 5
m] 6 8 . [15
1"
8'[2.
TREE TO BE REMOVED
46
]
m 91
[0.
m] .78 [12 TH 1 " EP '-1 G D 4 1 BLD
'-3 48 4.7 " [1
EX: 2
BUILDING - INTERIOR DESIGNERS
] 0m
46.6 '
] 0m ACK 1 . [3 SETB " 2 '- E 10 SID HT RIG
EX: 2 47.8
'
46.6
'
'-1
42
m]
.44
[35
CK
3"
6'-
m] TBA .92 SE ' [7 NT 26 FRO G TIN
IS EX
EX: 2
11
2m
2.8
" [1
m] ACK 2 8 . TB '6 [1 E SE SID T LEF ]
m .09
]
' [6 20
EX: 2 47.8 '
]
5m
0.7
" [2
'-1
68
m]
.92
' [7
26
UDC DESIGN CENTER LTD
m]
3'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
Site Plan
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/8" = 1'-0"
V01
SHEET NO:
A1
A1 A 36' 8'-5"
12'-3"
15'-4"
36' 9'
15'
12'
UP
3068
14'
14'
14'
UP
14'
UP
NOOK 5068
8'-6" x 14'-0"
BCB24R
B36
Proposed stairs for Basement
2268
SB35 2668
OPEN BELOW
RB60
BATH
WORKSHOP
DINING
42'-1"
BEDROOM
SB24R
B24R
10'-5" x 11'-6"
9'-6" x 10'-9" 2668
B2421R
2668
2468
9'-0" x 8'-9"
12'-0" x 13'-3"
OFFICE
KITCHEN
2668
42'-1"
14'-3"
11'-4" x 13'-3"
3014DH EXISITING
5'-0" x 7'-6"
2914DH
EXISITING
14'-3"
2668
LAUNDRY/ MECH. RM SB40
7'-6" x 10'-0"
2668
2668
4'-4" x CLOSET
1368
2668
5'-1" 2668
2668
13'-10"
8'-0" x 12'-9"
7'-6" x 9'-0"
15'-0" x 15'-3"
BEDROOM 9'-6" x 13'-3"
EXISITING
STORAGE
BEDROOM 3014DH
EXISITING 1614DH
13'-10"
1'-4" x 4'-2"
16'-3" x 12'-9"
2668
LIVING
CLOSET
FAMILY
28'-1"
2668
2668
2668
2668
2668
28'-1"
5'-2" x 5'-6"
28'-1"
BATH
28'-1"
BEDROOM 9'-8" x 9'-9"
CLOSET 2668
1'-4" x 4'-6" 2868
5'
BUILDING - INTERIOR DESIGNERS
10'-7" x 2'-9"
SB40
7'-10"
17'-4"
1'-9"
9'-1"
36' 2668
LEGEND:
10'
WIN. - CASEMENT
18' 36'
2668 2'-6" WIDTH x 6'-8" HEIGHT CS
8'
2668
ALL DOORS ARE HOLLOW CORE DOORS, OTHERWISE NOTED RS / LS WIN. - SLIDE TO RIGHT/LEFT FX
WIN. - FIXED
SG
SAFETY GLASS - WINDOW
HC
HOLLOW CORE - DOOR
SCW
SOLID CORE W/ WEATHER SEAL - DOOR
WB
WASH BASIN
WC
WATER CLOSET
F
OVERHEAD EXHAUST FAN
3068scw SOLID
S
CO
ST
A1 A
UDC DESIGN CENTER LTD
6068
CORE DOOR, W/WEATHER STRIPPING
INTERCONNECTED HARDWIRED SMOKE DETECTORS WITH A BATTERY BACKUP SMOKE ALARM & CARBON MONOXIDE (CO) ALARM SOLAR TUBES FOR DAYLIGHT ILLUMINATION AS PER THE MANU. SPECS.
NOTE: ALL LINTELS < 6'-0" LENGTH, SHALL BE 2 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS ALL LINTELS > 6'-0" LENGTH, SHALL BE 3 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
basement floor plan
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A2
A1 A 35'-6"
PROPOSED 6160TC
A1 A
12'-3"
7'-11"
15'-4"
5068
36' 18'-1"
3'-2"
17'-11" DCB3736R
11'-5"
FAMILY
KITCHEN
12'-3" x 13'-7"
8'-8" x 13'-7"
14'
3040RS PROPOSED
SB40
SB45
B4818
DN
DCB3336R
7'-5"
SB36
2840DH
2668
4668
SB36
2668
BATH
8'-0" x 5'-0" 2668
2468
2668
3'
8'-0" x 4'-11"
BATH
5'-8" x 5'-0"
3'-0" x 5'-0"
2668
2668
9'-6" x 11'-6"
9'-5" x 10'-2"
13'-0" x 13'-6"
BEDROOM 9'-6" x 10'-2"
2668
CLOSET
CLOSET 2'-0" x 3'-8"
BEDROOM
12'-3"
BEDROOM
BEDROOM
2668
10'-5"
Fireplace
2668
15'-0" x 23'-7"
2668
ENTRY
CLOSET
19'-5"
6068
LIVING
CLOSET
5'-10"
1960FX
OPEN BELOW
19'-5"
4'-2" x 2'-0"
2'-3"
5'-1" SB40
CLOSET
28'-1"
9'-1"
BATH 5'-0" x 8'-0"
3020RS PROPOSED
2668
SB4118
4'-2" x 5'-8"
3'-4"
4068
CLOSET
3'-0" x 5'-4"
5'
3'-9"
PROPOSED 5639DC
42'-1"
3068
10'-9" x 3'-0"
Closet 28'-1"
9'-6" x 6'-10"
RB46
2668
2668
5'-1"
42'-1"
KITCHEN
13'-7"
OPEN BELOW
21'-8" x 13'-11"
PROPOSED 3640RS
3068
2268
PROPOSED 2870FX
UP
DECK
5'-2"
13'-11"
5'-1"
13'-11"
RB78
5' 3'-10"
5'-2"
2840DH
Fireplace
5'-10"
14'
NEW EXTENSION
10'-7" x 3'-3"
5'-1"
5068
2'-0" x 7'-9"
31036DC
5668
DECK 15'-2" x 4'-11"
DECK
3068
5636DC
5636DC
3068
DECK
5646DC PROPOSED
DECK
12'-2" x 6'-0"
3870
2860FX PROPOSED 3870
9060TC PROPOSED
4'-11"
10'-11" x 6'-0"
6'-7" x 4'-4" 2'
5570
2' 2'
BUILDING - INTERIOR DESIGNERS
8'-8"
NEW EXTENSION 1'-1"
6'
9'-8"
7'-9"
2'-5"
15'-9"
4'-11"
5'-3"
20'-3" 3'-2" 36'
6'-11" 10'
2'-5"
5'-2"
4'-8"
6'-2"
12'-3"
7'-6" 13'-8"
36'
A1 A A1 A
UDC DESIGN CENTER LTD
6'-1"
21'-8"
1'-4"
6"
3'-5"
6'
B12R
BF6
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
main and top floor plan
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A3
MATERIAL SPECIFICATIONS
NEW EXTENSION
9' [2.74m]
SECOND FLOOR LVL. 258.4'
5
EX: 2
47.8
EX: 2
46.6
5'-7" [1.69m]
8'-612" [2.60m]
AVE. GRADE. LVL. 246.4'
1.
ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK
2.
INSIDE GUTTERS - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3.
1 x 4 OVER 2" X 10" FASCIA BOARD
4.
4" OR 6" WINDOW AND DOOR TRIM
5. 6.
ALUMINUM FRAMED WINDOW AND PATIO DOOR HARDY PANEL
7.
WOODEN EXTERIOR DOOR
8. 9.
STONE CEDAR
4
MAIN FL. LVL. 249.4'
PROPOSED GRADE EX: 2 46.6 ' P.EL .: 24 6.6'
' '
P.EL
.: 24 6.6'
FRONT ELEVATION SCALE:1/4"-1'
MEAN ROOF LVL. 269.9'
8' [2.44m]
U/S CEILING LVL. 266.4'
9' [2.74m]
SECOND FLOOR LVL. 258.4'
27'-4" [8.32m]
ROOF RIDGE LVL. 273.5'
3'-73 4" [1.11m]3'-73 4" [1.11m]
BSMT. FL. LVL. 240.8'
MAIN FL. LVL. 249.4'
RIGHT ELEVATION
47.8
5'-7" [1.69m]
AVE. GRADE. LVL. 246.4'
EX: 2 8'-612" [2.60m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
2 3
8' [2.44m]
U/S CEILING LVL. 266.4'
1
27'-4" [8.32m]
MEAN ROOF LVL. 269.9'
3'-73 4" [1.11m]3'-73 4" [1.11m]
ROOF RIDGE LVL. 273.5'
P.EL
EX: 2
'
46.6
'
.: 24
6.6'
BSMT. FL. LVL. 240.8'
SCALE:1/4"-1'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
front and right elevation
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A4
9' [2.74m]
SECOND FLOOR LVL. 258.4'
6
EXISTING GRADE
MAIN FL. LVL. 249.4'
EX: 2 EX: 2
47.8 '
46.6
'
5'-7" [1.69m]
8'-612" [2.60m]
AVE. GRADE. LVL. 246.4'
REAR ELEVATION
MEAN ROOF LVL. 269.9'
SCALE:1/4"-1'
8' [2.44m]
U/S CEILING LVL. 266.4'
SECOND FLOOR LVL. 258.4'
27'-4" [8.32m]
ROOF RIDGE LVL. 273.5'
3'-73 4" [1.11m]3'-73 4" [1.11m]
BSMT. FL. LVL. 240.8'
9' [2.74m]
6
EXISTING GRADE
MAIN FL. LVL. 249.4'
EX: 2
47.8
LEFT ELEVATION
EX: 2
'
47.8
'
P.EL
5'-7" [1.69m]
AVE. GRADE. LVL. 246.4'
8'-612" [2.60m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
8' [2.44m]
U/S CEILING LVL. 266.4'
27'-4" [8.32m]
MEAN ROOF LVL. 269.9'
3'-73 4" [1.11m]3'-73 4" [1.11m]
ROOF RIDGE LVL. 273.5'
.: 24
6.6'
BSMT. FL. LVL. 240.8'
SCALE:1/4"-1'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
rear and left elevation
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A5
6
SECTIONAL DETAILS AND SPECIFICATIONS: CLOSET
BEDROOM
1
DECK
2
DECK
KITCHEN
FOYER
3870
6068
5068
NEW EXTENSION
3
2268
5'-7" [1.69m]
8'-612" [2.60m]
4
BATH
LAUNDRY/ MECH. RM
BSMT. FL. LVL. 240.8'
SB3218
MAIN AND UPPER FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION - 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)
6
BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL
INTERIOR PARTITIONS ( 1 hr FRR):
EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
2668
6
EAVES:
- 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY
MAIN FL. LVL. 249.4'
BEDROOM
5
- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
5
AVE. GRADE. LVL. 246.4'
ROOF: - ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
2468
9' [2.74m]
SECOND FLOOR LVL. 258.4'
12
1
27'-4" [8.32m]
8' [2.44m]
U/S CEILING LVL. 266.4'
3'-73 4" [1.11m]3'-73 4" [1.11m]
MEAN ROOF LVL. 269.9'
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
ROOF RIDGE LVL. 273.5'
DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
7
FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE
INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL
SECTION A-1 SCALE:1/4"-1'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
section and detail
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A6
SPECIFICATIONS AND GENERAL NOTES:
BUILDING SPEC. LIST:
EXTERIOR BUILDING FINISH MATERIALS:
1. ROOF (TRUSS):
7. UPPER FLOOR:
1. ROOF FINISH: ASPHALT SHINGLE 2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE 3. EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME 4. WINDOW TRIMS: HARDITRIM 5. SOFFITS: VENTED HARDISOFFIT
1HR. FIRE RATED FOR WALLS AND CLG.
GENERAL NOTES
SECTION 07200
123456-
VAPOR BARRIER / VAPOR RETARDER PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.
78-
WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4. CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS
9- ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. 10- PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING. 11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN. 12 - DWELLING SECURITY AS PER # 9.6.8 13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.
SECTION 06100 ROUGH CARPENTRY
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
2. CEILING:
LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.
SECTION 07200 INSULATION: PRODUCTS: EXTRUDED POLYSTYRENE: STANDARD CGSB51-GP-20M,TYPE 4. R: 5 PER INCH, RICHNESS: AS REQUIRED TO MEET P VALUE, LOCATION: FOUNDATION INSULATION. EXPANDED POLYSTYRENE: STANDARD: CGB51-GP-20M, TYPE 2, R: 4 PER INCH. THICKNESS: AS REQUIRED TO MEET R VALUE. LOCATION: CAVITY WALLS. BATT INSULATION: STANDARD: CSA A101-M83, TYPE 1. R VALUE: 19 . LOCATION WITHIN WOOD STUD WALLS, AND R 38 WITHIN CEILING. EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT USE CHIPPED OR CRACKED INSULATION BOARDS. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS. INSTALL INSULATION IN CONTINUOS CONTACT WITH INTERIOR SHEATING. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
1'-6" [0.46m]
8. FLOOR SLAB:
3. ROOF (RAFTERED): 9. FOUNDATION:
SECTION 07270 AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.
4. FASCIA:
11. STAIRS: 5. EXTERIOR WALL:
4
SECTION 07300
12 12. BEARING WALL
1'-6" [0.46m]
ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.
NOTES FOR ROOF SPACE VENTILATION 1. 2.
UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.
3. 4. 5. 6. 7.
PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.
6. INTERIOR WALL: 13. CRAWL SPACE:
4
12
4
E.EL. 252.34 P.EL. 252.84
E.EL. 251.44 P.EL. 252.84
4
12
E.EL. 251.44 P.EL. 252.84
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
GARAGE DETAILS
12
E.EL. 252.44 P.EL. 252.84
E.EL. 252.92 P.EL. 252.84
4
E.EL. 252.44 P.EL. 252.84
CLIENT:
10. DRAINAGE:
12
E.EL. 252.92 P.EL. 252.84
E.EL. 252.34 P.EL. 252.84
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
1/4"=1'-0"
V01
SHEET NO:
A7
8' [2.44m]
U/S CEILING LVL. 266.4'
SECOND FLOOR LVL. 258.4'
9' [2.74m]
27'-4" [8.32m]
MEAN ROOF LVL. 269.9'
BUILDING - INTERIOR DESIGNERS
AVE. GRADE. LVL. 246.4'
5'-7" [1.69m]
MAIN FL. LVL. 249.4'
8'-612" [2.60m]
UDC DESIGN CENTER LTD
ROOF RIDGE LVL. 273.5'
3'-73 4" [1.11m]3'-73 4" [1.11m]
â&#x2C6;&#x2122;
BSMT. FL. LVL. 240.8'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
ENERGY DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
SHEET NO:
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
N.T.S.
V01
A8
GRID
GRID
HEADER
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING
MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
4" ADHERED FLASHING MEMBRANE
INTERIOR
EXTERIOR
4" FLANGE 6
100 mm (4")
FLOOR FINISH ON CONCRETE TOPPING
SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN
MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)
2"CONTINUOUS FLANGE AT PERIMETER OF HOOD
STUD @ 16" O.C
2"
2
SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
1 MIN 2"
BLDG. PAPER 2X10 FLOOR JOISTS
4.06
23.03
SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)
PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME
VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 3.99
22.61
.12
0.68
4.11
23.29
ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM
RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12
R 0.44 0.00 0.77 50.0 0.00 0.45 0.68
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
9.21
50.34
FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE
RSI 0.03 0.12 0.00 0.15 4.99 0.00
R 0.17 0.68 0.00 0.83 28.00 0.00
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
5.29
29.68
TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME
USI
U
1.4
0.246
1" 2
SEPERATION AIR SPACE
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
1 MIN.
ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW
SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
2a
2 SEALANT OR GASKET (A.B.)
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
12mm (1/2")
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)
1X2 STRAPPING
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
1.5" SILL PLATE
BUILDING - INTERIOR DESIGNERS
EXTERIOR STUCCO CLADDING
- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )
INTERIOR
AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION
THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)
SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)
FLASHING & COUNTER FLASHING
SEALANT OR GASKET (A.B.)
ASPHALT IMPREGNATED PAPER
INSECT SCREEN - NO DAMPERS
EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD
GRID
1/2″ (12.7 MM) PLYWOOD SHEATHING
2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT
POLYETHYLENE VAPOR BARRIER
ADHERE SUBFLOOR TO HEADER (A.B.)
1/2″ (12.7 MM) GYPSUM BOARD
MIN. 2% SLOPE TO DRAIN
FLOOR FINISH ON CONCRETE TOPPING
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)
2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING
SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL
INSULATION GUARD
POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)
EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
GASKET (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)
W-1
SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING
SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING
INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)
HOUSEWRAP AT HEADER (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD
BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE
25mm (1")
ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)
2" MIN.
FILTER CLOTH
CEMENT OR ACRYLIC STUCCO PARGING
SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS
DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
8" CONC. FOUNDATION WALL
FINISHED GRADE
4" EXTRUDED POLYSTYRENE R-5/in. 1" 2
REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL
DRYWALL FINISH
912"
INSECT SCREEN
VENTED ALUMINUM SOFFIT PANELS
FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06
512"
CEMENT OR ACRYLIC STUCCO PARGING
8" MINIMUM
SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL HOUSEWRAP (A.B.) TO FRAMING
CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL
ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER
INTERIOR
1/2"
UDC DESIGN CENTER LTD
ROD AND SEALANT
4" FLANGE
25.4mm (1")
RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12
WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
SHEATHING PAPER TO LAP METAL FLASHING
ROD AND SEALANT 1
WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
4"
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI / R VALUE CALCULATIONS FOR ASSEMBLIES
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
GRID
COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.
WOOD FRAMING (STUDS OR STRAPPING)
W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620
GENERAL DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1280
DATE:
MAY 2017
FILE NO.
SCALE:
N.T.S.
V01
SHEET NO:
A9