213 9th ave akbar

Page 1

13'-112" [4.00m]

] 3m 4.7 CK " [1 BA '-4 ET 48 AR S RE

" '-1 2 5

m] 6 8 . [15

1"

8'[2.

TREE TO BE REMOVED

46

]

m 91

[0.

m] .78 [12 TH 1 " EP '-1 G D 4 1 BLD

'-3 48 4.7 " [1

EX: 2

BUILDING - INTERIOR DESIGNERS

] 0m

46.6 '

] 0m ACK 1 . [3 SETB " 2 '- E 10 SID HT RIG

EX: 2 47.8

'

46.6

'

'-1

42

m]

.44

[35

CK

3"

6'-

m] TBA .92 SE ' [7 NT 26 FRO G TIN

IS EX

EX: 2

11

2m

2.8

" [1

m] ACK 2 8 . TB '6 [1 E SE SID T LEF ]

m .09

]

' [6 20

EX: 2 47.8 '

]

5m

0.7

" [2

'-1

68

m]

.92

' [7

26

UDC DESIGN CENTER LTD

m]

3'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

Site Plan

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/8" = 1'-0"

V01

SHEET NO:

A1


A1 A 36' 8'-5"

12'-3"

15'-4"

36' 9'

15'

12'

UP

3068

14'

14'

14'

UP

14'

UP

NOOK 5068

8'-6" x 14'-0"

BCB24R

B36

Proposed stairs for Basement

2268

SB35 2668

OPEN BELOW

RB60

BATH

WORKSHOP

DINING

42'-1"

BEDROOM

SB24R

B24R

10'-5" x 11'-6"

9'-6" x 10'-9" 2668

B2421R

2668

2468

9'-0" x 8'-9"

12'-0" x 13'-3"

OFFICE

KITCHEN

2668

42'-1"

14'-3"

11'-4" x 13'-3"

3014DH EXISITING

5'-0" x 7'-6"

2914DH

EXISITING

14'-3"

2668

LAUNDRY/ MECH. RM SB40

7'-6" x 10'-0"

2668

2668

4'-4" x CLOSET

1368

2668

5'-1" 2668

2668

13'-10"

8'-0" x 12'-9"

7'-6" x 9'-0"

15'-0" x 15'-3"

BEDROOM 9'-6" x 13'-3"

EXISITING

STORAGE

BEDROOM 3014DH

EXISITING 1614DH

13'-10"

1'-4" x 4'-2"

16'-3" x 12'-9"

2668

LIVING

CLOSET

FAMILY

28'-1"

2668

2668

2668

2668

2668

28'-1"

5'-2" x 5'-6"

28'-1"

BATH

28'-1"

BEDROOM 9'-8" x 9'-9"

CLOSET 2668

1'-4" x 4'-6" 2868

5'

BUILDING - INTERIOR DESIGNERS

10'-7" x 2'-9"

SB40

7'-10"

17'-4"

1'-9"

9'-1"

36' 2668

LEGEND:

10'

WIN. - CASEMENT

18' 36'

2668 2'-6" WIDTH x 6'-8" HEIGHT CS

8'

2668

ALL DOORS ARE HOLLOW CORE DOORS, OTHERWISE NOTED RS / LS WIN. - SLIDE TO RIGHT/LEFT FX

WIN. - FIXED

SG

SAFETY GLASS - WINDOW

HC

HOLLOW CORE - DOOR

SCW

SOLID CORE W/ WEATHER SEAL - DOOR

WB

WASH BASIN

WC

WATER CLOSET

F

OVERHEAD EXHAUST FAN

3068scw SOLID

S

CO

ST

A1 A

UDC DESIGN CENTER LTD

6068

CORE DOOR, W/WEATHER STRIPPING

INTERCONNECTED HARDWIRED SMOKE DETECTORS WITH A BATTERY BACKUP SMOKE ALARM & CARBON MONOXIDE (CO) ALARM SOLAR TUBES FOR DAYLIGHT ILLUMINATION AS PER THE MANU. SPECS.

NOTE: ALL LINTELS < 6'-0" LENGTH, SHALL BE 2 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS ALL LINTELS > 6'-0" LENGTH, SHALL BE 3 - 2x10 SPF # 2 W/ NO SPLICING PERMITTED B/W SUPPORTS

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

basement floor plan

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A2


A1 A 35'-6"

PROPOSED 6160TC

A1 A

12'-3"

7'-11"

15'-4"

5068

36' 18'-1"

3'-2"

17'-11" DCB3736R

11'-5"

FAMILY

KITCHEN

12'-3" x 13'-7"

8'-8" x 13'-7"

14'

3040RS PROPOSED

SB40

SB45

B4818

DN

DCB3336R

7'-5"

SB36

2840DH

2668

4668

SB36

2668

BATH

8'-0" x 5'-0" 2668

2468

2668

3'

8'-0" x 4'-11"

BATH

5'-8" x 5'-0"

3'-0" x 5'-0"

2668

2668

9'-6" x 11'-6"

9'-5" x 10'-2"

13'-0" x 13'-6"

BEDROOM 9'-6" x 10'-2"

2668

CLOSET

CLOSET 2'-0" x 3'-8"

BEDROOM

12'-3"

BEDROOM

BEDROOM

2668

10'-5"

Fireplace

2668

15'-0" x 23'-7"

2668

ENTRY

CLOSET

19'-5"

6068

LIVING

CLOSET

5'-10"

1960FX

OPEN BELOW

19'-5"

4'-2" x 2'-0"

2'-3"

5'-1" SB40

CLOSET

28'-1"

9'-1"

BATH 5'-0" x 8'-0"

3020RS PROPOSED

2668

SB4118

4'-2" x 5'-8"

3'-4"

4068

CLOSET

3'-0" x 5'-4"

5'

3'-9"

PROPOSED 5639DC

42'-1"

3068

10'-9" x 3'-0"

Closet 28'-1"

9'-6" x 6'-10"

RB46

2668

2668

5'-1"

42'-1"

KITCHEN

13'-7"

OPEN BELOW

21'-8" x 13'-11"

PROPOSED 3640RS

3068

2268

PROPOSED 2870FX

UP

DECK

5'-2"

13'-11"

5'-1"

13'-11"

RB78

5' 3'-10"

5'-2"

2840DH

Fireplace

5'-10"

14'

NEW EXTENSION

10'-7" x 3'-3"

5'-1"

5068

2'-0" x 7'-9"

31036DC

5668

DECK 15'-2" x 4'-11"

DECK

3068

5636DC

5636DC

3068

DECK

5646DC PROPOSED

DECK

12'-2" x 6'-0"

3870

2860FX PROPOSED 3870

9060TC PROPOSED

4'-11"

10'-11" x 6'-0"

6'-7" x 4'-4" 2'

5570

2' 2'

BUILDING - INTERIOR DESIGNERS

8'-8"

NEW EXTENSION 1'-1"

6'

9'-8"

7'-9"

2'-5"

15'-9"

4'-11"

5'-3"

20'-3" 3'-2" 36'

6'-11" 10'

2'-5"

5'-2"

4'-8"

6'-2"

12'-3"

7'-6" 13'-8"

36'

A1 A A1 A

UDC DESIGN CENTER LTD

6'-1"

21'-8"

1'-4"

6"

3'-5"

6'

B12R

BF6

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

main and top floor plan

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A3


MATERIAL SPECIFICATIONS

NEW EXTENSION

9' [2.74m]

SECOND FLOOR LVL. 258.4'

5

EX: 2

47.8

EX: 2

46.6

5'-7" [1.69m]

8'-612" [2.60m]

AVE. GRADE. LVL. 246.4'

1.

ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK

2.

INSIDE GUTTERS - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

3.

1 x 4 OVER 2" X 10" FASCIA BOARD

4.

4" OR 6" WINDOW AND DOOR TRIM

5. 6.

ALUMINUM FRAMED WINDOW AND PATIO DOOR HARDY PANEL

7.

WOODEN EXTERIOR DOOR

8. 9.

STONE CEDAR

4

MAIN FL. LVL. 249.4'

PROPOSED GRADE EX: 2 46.6 ' P.EL .: 24 6.6'

' '

P.EL

.: 24 6.6'

FRONT ELEVATION SCALE:1/4"-1'

MEAN ROOF LVL. 269.9'

8' [2.44m]

U/S CEILING LVL. 266.4'

9' [2.74m]

SECOND FLOOR LVL. 258.4'

27'-4" [8.32m]

ROOF RIDGE LVL. 273.5'

3'-73 4" [1.11m]3'-73 4" [1.11m]

BSMT. FL. LVL. 240.8'

MAIN FL. LVL. 249.4'

RIGHT ELEVATION

47.8

5'-7" [1.69m]

AVE. GRADE. LVL. 246.4'

EX: 2 8'-612" [2.60m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

2 3

8' [2.44m]

U/S CEILING LVL. 266.4'

1

27'-4" [8.32m]

MEAN ROOF LVL. 269.9'

3'-73 4" [1.11m]3'-73 4" [1.11m]

ROOF RIDGE LVL. 273.5'

P.EL

EX: 2

'

46.6

'

.: 24

6.6'

BSMT. FL. LVL. 240.8'

SCALE:1/4"-1'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

front and right elevation

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A4


9' [2.74m]

SECOND FLOOR LVL. 258.4'

6

EXISTING GRADE

MAIN FL. LVL. 249.4'

EX: 2 EX: 2

47.8 '

46.6

'

5'-7" [1.69m]

8'-612" [2.60m]

AVE. GRADE. LVL. 246.4'

REAR ELEVATION

MEAN ROOF LVL. 269.9'

SCALE:1/4"-1'

8' [2.44m]

U/S CEILING LVL. 266.4'

SECOND FLOOR LVL. 258.4'

27'-4" [8.32m]

ROOF RIDGE LVL. 273.5'

3'-73 4" [1.11m]3'-73 4" [1.11m]

BSMT. FL. LVL. 240.8'

9' [2.74m]

6

EXISTING GRADE

MAIN FL. LVL. 249.4'

EX: 2

47.8

LEFT ELEVATION

EX: 2

'

47.8

'

P.EL

5'-7" [1.69m]

AVE. GRADE. LVL. 246.4'

8'-612" [2.60m]

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

8' [2.44m]

U/S CEILING LVL. 266.4'

27'-4" [8.32m]

MEAN ROOF LVL. 269.9'

3'-73 4" [1.11m]3'-73 4" [1.11m]

ROOF RIDGE LVL. 273.5'

.: 24

6.6'

BSMT. FL. LVL. 240.8'

SCALE:1/4"-1'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

rear and left elevation

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A5


6

SECTIONAL DETAILS AND SPECIFICATIONS: CLOSET

BEDROOM

1

DECK

2

DECK

KITCHEN

FOYER

3870

6068

5068

NEW EXTENSION

3

2268

5'-7" [1.69m]

8'-612" [2.60m]

4

BATH

LAUNDRY/ MECH. RM

BSMT. FL. LVL. 240.8'

SB3218

MAIN AND UPPER FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION - 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)

6

BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL

INTERIOR PARTITIONS ( 1 hr FRR):

EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

2668

6

EAVES:

- 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY

MAIN FL. LVL. 249.4'

BEDROOM

5

- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT

5

AVE. GRADE. LVL. 246.4'

ROOF: - ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.

2468

9' [2.74m]

SECOND FLOOR LVL. 258.4'

12

1

27'-4" [8.32m]

8' [2.44m]

U/S CEILING LVL. 266.4'

3'-73 4" [1.11m]3'-73 4" [1.11m]

MEAN ROOF LVL. 269.9'

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

ROOF RIDGE LVL. 273.5'

DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP

7

FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE

INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL

SECTION A-1 SCALE:1/4"-1'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

section and detail

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A6


SPECIFICATIONS AND GENERAL NOTES:

BUILDING SPEC. LIST:

EXTERIOR BUILDING FINISH MATERIALS:

1. ROOF (TRUSS):

7. UPPER FLOOR:

1. ROOF FINISH: ASPHALT SHINGLE 2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE 3. EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME 4. WINDOW TRIMS: HARDITRIM 5. SOFFITS: VENTED HARDISOFFIT

1HR. FIRE RATED FOR WALLS AND CLG.

GENERAL NOTES

SECTION 07200

123456-

VAPOR BARRIER / VAPOR RETARDER PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.

78-

WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4. CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS

9- ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. 10- PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING. 11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN. 12 - DWELLING SECURITY AS PER # 9.6.8 13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.

SECTION 06100 ROUGH CARPENTRY

BUILDING - INTERIOR DESIGNERS

UDC DESIGN CENTER LTD

2. CEILING:

LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.

SECTION 07200 INSULATION: PRODUCTS: EXTRUDED POLYSTYRENE: STANDARD CGSB51-GP-20M,TYPE 4. R: 5 PER INCH, RICHNESS: AS REQUIRED TO MEET P VALUE, LOCATION: FOUNDATION INSULATION. EXPANDED POLYSTYRENE: STANDARD: CGB51-GP-20M, TYPE 2, R: 4 PER INCH. THICKNESS: AS REQUIRED TO MEET R VALUE. LOCATION: CAVITY WALLS. BATT INSULATION: STANDARD: CSA A101-M83, TYPE 1. R VALUE: 19 . LOCATION WITHIN WOOD STUD WALLS, AND R 38 WITHIN CEILING. EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT USE CHIPPED OR CRACKED INSULATION BOARDS. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS. INSTALL INSULATION IN CONTINUOS CONTACT WITH INTERIOR SHEATING. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

1'-6" [0.46m]

8. FLOOR SLAB:

3. ROOF (RAFTERED): 9. FOUNDATION:

SECTION 07270 AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.

4. FASCIA:

11. STAIRS: 5. EXTERIOR WALL:

4

SECTION 07300

12 12. BEARING WALL

1'-6" [0.46m]

ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.

NOTES FOR ROOF SPACE VENTILATION 1. 2.

UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.

3. 4. 5. 6. 7.

PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.

6. INTERIOR WALL: 13. CRAWL SPACE:

4

12

4

E.EL. 252.34 P.EL. 252.84

E.EL. 251.44 P.EL. 252.84

4

12

E.EL. 251.44 P.EL. 252.84

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

GARAGE DETAILS

12

E.EL. 252.44 P.EL. 252.84

E.EL. 252.92 P.EL. 252.84

4

E.EL. 252.44 P.EL. 252.84

CLIENT:

10. DRAINAGE:

12

E.EL. 252.92 P.EL. 252.84

E.EL. 252.34 P.EL. 252.84

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

1/4"=1'-0"

V01

SHEET NO:

A7


8' [2.44m]

U/S CEILING LVL. 266.4'

SECOND FLOOR LVL. 258.4'

9' [2.74m]

27'-4" [8.32m]

MEAN ROOF LVL. 269.9'

BUILDING - INTERIOR DESIGNERS

AVE. GRADE. LVL. 246.4'

5'-7" [1.69m]

MAIN FL. LVL. 249.4'

8'-612" [2.60m]

UDC DESIGN CENTER LTD

ROOF RIDGE LVL. 273.5'

3'-73 4" [1.11m]3'-73 4" [1.11m]

∙

BSMT. FL. LVL. 240.8'

UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

ENERGY DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

SHEET NO:

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

N.T.S.

V01

A8


GRID

GRID

HEADER

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING

MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

4" ADHERED FLASHING MEMBRANE

INTERIOR

EXTERIOR

4" FLANGE 6

100 mm (4")

FLOOR FINISH ON CONCRETE TOPPING

SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN

MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)

2"CONTINUOUS FLANGE AT PERIMETER OF HOOD

STUD @ 16" O.C

2"

2

SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

1 MIN 2"

BLDG. PAPER 2X10 FLOOR JOISTS

4.06

23.03

SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)

PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME

VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 3.99

22.61

.12

0.68

4.11

23.29

ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM

RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12

R 0.44 0.00 0.77 50.0 0.00 0.45 0.68

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

9.21

50.34

FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE

RSI 0.03 0.12 0.00 0.15 4.99 0.00

R 0.17 0.68 0.00 0.83 28.00 0.00

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

5.29

29.68

TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME

USI

U

1.4

0.246

1" 2

SEPERATION AIR SPACE

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

1 MIN.

ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW

SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

2a

2 SEALANT OR GASKET (A.B.)

EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68

EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY

12mm (1/2")

SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)

1X2 STRAPPING

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

1.5" SILL PLATE

BUILDING - INTERIOR DESIGNERS

EXTERIOR STUCCO CLADDING

- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )

INTERIOR

AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION

THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)

SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)

FLASHING & COUNTER FLASHING

SEALANT OR GASKET (A.B.)

ASPHALT IMPREGNATED PAPER

INSECT SCREEN - NO DAMPERS

EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD

GRID

1/2″ (12.7 MM) PLYWOOD SHEATHING

2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT

POLYETHYLENE VAPOR BARRIER

ADHERE SUBFLOOR TO HEADER (A.B.)

1/2″ (12.7 MM) GYPSUM BOARD

MIN. 2% SLOPE TO DRAIN

FLOOR FINISH ON CONCRETE TOPPING

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)

2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING

SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL

INSULATION GUARD

POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)

EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

GASKET (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED

LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)

W-1

SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING

SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING

INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)

HOUSEWRAP AT HEADER (A.B.)

BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD

BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE

25mm (1")

ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)

2" MIN.

FILTER CLOTH

CEMENT OR ACRYLIC STUCCO PARGING

SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS

DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

8" CONC. FOUNDATION WALL

FINISHED GRADE

4" EXTRUDED POLYSTYRENE R-5/in. 1" 2

REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL

DRYWALL FINISH

912"

INSECT SCREEN

VENTED ALUMINUM SOFFIT PANELS

FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06

512"

CEMENT OR ACRYLIC STUCCO PARGING

8" MINIMUM

SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

SEAL HOUSEWRAP (A.B.) TO FRAMING

CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL

ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER

INTERIOR

1/2"

UDC DESIGN CENTER LTD

ROD AND SEALANT

4" FLANGE

25.4mm (1")

RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12

WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM

SHEATHING PAPER TO LAP METAL FLASHING

ROD AND SEALANT 1

WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM VALUES ADOPTED FROM CANADIAN WOOD COUNCIL

4"

EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6

RSI / R VALUE CALCULATIONS FOR ASSEMBLIES

EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING

GRID

COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.

WOOD FRAMING (STUDS OR STRAPPING)

W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM

CLIENT:

SHEET TITLE:

MOHAMMAD RASOULI PROJECT: CIVIC ADDRESS: 213 9TH AVE, BC LEGAL DESCRIPTION: LOT 15 BLOCK 14 GROUP 1 NWD PLAN 2620

GENERAL DETAIL

DRAWN BY:

G.S.B.

PROJECT NO.

CHECKED BY:

B.M.

1280

DATE:

MAY 2017

FILE NO.

SCALE:

N.T.S.

V01

SHEET NO:

A9