CIVIC ADDRESS
6398 - 120TH STREET, SURREY B.C.
LEGAL DESCRIPTION
LOT D SEC. 7 TP. 2 NWS PLAN LMD 35534 CD 36,388 S.F. (3,659.27 SM) 32.23% 1205.19 SQFT 27'-2" (8.28M) 0.32
PARKING : (NOTE AREAS EXCLUDE STAIRS)
REQUIRED ,
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
ZONING , SITE AREA , SITE COVERAGE , PROPOSED UNIT AREA BUILDING HEIGHT F. A. R. ,
PROPOSED UNIT PLAN
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
Dr. Vohra - Medical Clinic PROJECT:
SITE PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
XXXX
DATE:
NOV. 2016
FILE NO.
CIVIC ADDRESS:UNIT #102 -6398 120St, SURREY, BC SCALE:
1/8" = 1' - 0"
V01
SHEET NO:
A 1/3
LEGEND: EXIT SIGN EMERGENCY LIGHT EXHAUST FAN BUILDING IS FULLY SPRINKLED All Interior Walls are 8' High
PROPOSED WALL EXISTING WALL 72'-1" 5'
7'-4"
12'-6"
7'-4"
7'-4"
5'-9"
5'-5"
5'-4"
4'-4"
TRAVEL DISTANCE
5'
6'-8"
OCCUPANT LOAD (BCBC 2006 3.1.17): 12 PERSONS ( Max. ) 8'-6"
3068
2668
2668
6'-5"
A A1
5'
5'-6"
7'-1"
5'-6"
24'-7"
2668
ONE EXISTING WASHROOM WITHIN SUBJECT UNIT IS H/C ONE PROPOSED WASHROOM WITHIN SUBJECT UNIT IS H/C
16'-1"
2668
2668
A A1
2668
WASHROOM / WATER CLOSET (BCBC 2006 3.7.2.4)
4'-1"
18'-7"
2668
10'
8'-6"
2668
24'-1"
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
FYI DOCTOR (OPTOMETRY)
19'-6"
4'-5"
4'-1"
4'
16'-5" 24'-6"
19'
6'-7"
5'-1" 11'-7"
7'-1"
5' 12'
72'-1"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
Dr. Vohra - Medical Clinic PROJECT:
PRPOSED CLINIC LAYOUT PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
XXXX
DATE:
NOV. 2016
FILE NO.
CIVIC ADDRESS:UNIT #102 -6398 120St, SURREY, BC SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
2/4
GENERAL NOTES 1.
GENERAL CONTRACTOR SHALL ENSURE CONTINUOUS MAINTENANCE OF SITE DURING CONSTRUCTION FOR PROTECTION OF ALL MATERIALS, DONE TO DATE.
SHELL BUILDING GENERAL INFORMATION BUILDING A A) B) C)
BUILDING DESIGN UNDER B.C.B.C. 2012 EDITION APPLICABLE UNDER PART 3 MAJOR OCCUPANCY, GROUP E -COMBUSTIBLE, NON SPRINKLERED BUILDING AREA: 5940 S.F. (552 SM) BUILDING HEIGHT : 1 STOREY STREETS: FACES TWO STREETS ACCESSIBLE ENTRANCES: TWO ENTRANCES ACCESSIBLE FACILITIES: UNIVERSAL TOILET ROOM
2.
ALL PARTITIONS ARE TO BE CHALKED ON SITE AND APPROVED BY DESIGNER AND CLIENT PRIOR TO INSTALLATION OF FLOOR TRACK.
3.
GENERAL CONTRACTOR TO ENSURE SUFFICIENT BLOCKING IS PROVIDED IN AL AREAS REQUIRING SUPPORT OF WALL OR CEILING MOUNTED EQUIPMENT OR MATERIALS.
4.
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
D)
UNLESS OTHERWISE NOTED ON DRAWINGS/DETAILS, ALL DRYWALL PARTITIONS SHALL CONSIST OF 1/2" DRYWALL, APPLIED TO 3 5/8" STEEL STUD,,,INTERIOR CAVITIES TO BE FILLED WITH FIBREGLASS NOISE STOP BATT INSULATION.
5.
ALL STEEL STUDS TO BE LOCATED AT 16" O.C. UNLESS OTHERWISE NOTED ON PLAN.
6.
ALL DRYWALL SHALL BE TAPED, FILLED AND SANDED AND PREPARED TO ACCEPT FINISH.
E) F) G)
SHELL BUILDING (BUILDING A) DATA LEGAL DESCRIPTION 35534 CIVIC ADDRESS B.C. ZONING , SITE AREA , SITE COVERAGE , BUILDING HEIGHT F. A. R. , PARKING : (NOTE AREAS EXCLUDE STAIRS) S.F.) 5.5 SPACES
LOT D SEC. 7 TP. 2 NWS PLAN LMD 6398 - 120TH STREET, SURREY CD 36,388 S.F. (3,659.27 SM) 32.23% 27'-2" (8.28M) 0.32 REQUIRED , OFFICES
5,940 S.F. (1/1076.4
HARDIE PANEL SIDING PLYWOOD SHEATING 2X6 WOOD STUDS 1/2 GYPSUM BOARD, PAINTED
EXTERIOR WALL
NON-LOAD BEARING 1/2" GYPSUM BOARD, PAINTED 2 X 4 WOOD STUDS 1/2" GYPSUM BOARD, PAINTED
SUSPENDED CEILING
PROPOSED INTERIOR PARTITION NON-LOAD BEARING 5/8" GYPSUM BOARD, PAINTED 2 X 4 WOOD STUDS 5/8" GYPSUM BOARD, PAINTED
EXISTING INTERIOR PARTITION (1HR FRR FIRE SEPARATION)
NON-LOAD BEARING 1/2" GYPSUM BOARD, PAINTED 2 X 4 STUDS
INTERIOR CHASE WALL
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
Dr. Vohra - Medical Clinic PROJECT:
SECTION DETAIL PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
XXXX
DATE:
NOV. 2016
FILE NO.
CIVIC ADDRESS:UNIT #102 -6398 120St, SURREY, BC SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
3/4
EXISTING ACOUSTIC TILE CEILING
2 X 6 @ 2' O.C. WOOD STRUCTURE C/N
9'
12'
ABOVE FLOOR FINISHED
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
NOTES: PROVIDE THIRD PARTY ACCEPTANCE OF SEISMIC RESTRAINT INSTALLATION OF SUSPENDED CEILINGS BY A REGISTERED BC ENGINEER
CONTINUOUS SEALANT
FLOOR FINISHES PER INTERIOR DESIGNER SPECIFICATIONS
DASHED LINE INDICATES EXISTING CONTINUOUS VAPOUR BARRIER TOP OF SLAB
SECTION DETAIL INTERIOR WALL ASSEMBLY F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD
A
FLOOR JOIST
W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD
5
8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)
W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD
F.R.R WALL DETAIL
30 MIN. F.R.R. ASSEMBLY DETAIL SUBFLOOR
NOTCH OUT 21" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS
5
8"
TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL
DETAIL AT 'A'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD
F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD
F.R.R. CEILING DETAIL
CLIENT:
SHEET TITLE:
Proposed Medical Clinic PROJECT:
SECTION DETAIL PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
XXXX
DATE:
NOV. 2016
FILE NO.
CIVIC ADDRESS:UNIT #102 -6398 120St, SURREY, BC SCALE:
1/4"=1'-0"
V01
SHEET NO:
A
4/4