DALI 2in1 Rotary Dimmer 046PDPE Series: F92002-04638301 DALI DT6 & DALI DT8 Tunable White
LEDGEAR® Dimmer Specification GENERAL GUIDELINES This DALI MCU(Microcontroller) with DALI output for dimming of luminaires or transformers with DALI interface. Flush-mounted Rotary Dimmer for DALI DT6 and DT8 Tunable White applications, integrated DALI bus power supply of 92 which can power DALI bus while connected to AC mains. While not connected to AC mains, the DALI rotary dimmer can be powered by DALI bus. Broadcast control up to 46 DALI devices from one dimmer, and possible to extend installation with up to 4 dimmers(for multiple control locations) and 92 DALI-devices. Supplied without knob and front frame but compatible with most of the European frames, 5-year warranty. Dimming solutions are easy and reliable, no DALI addressing required. Switch-on with brightness thanks for the permanently. Double click enables users to switch between dimming and tuning(for DT8 only).
Product description • •
Works with DALI-2 DT6 and DALI DT8 Tc(Tunable White) ECGs 0.1% -100% dimming range
• •
2000K - 10000K color temperature tuning range with DALI DT8 Switch-on with last brightness or saved switch-on brightness
•
Switch-on brightness can be saved permanently
• •
92mA integrated DALI bus power supply when connected to AC mains Each DALI dimmer can control up to 46 DALI ECGs
•
Control up to 92 DALI ECGs with maximum 2 active DALI MCUs powered by AC mains and 2 passive MCUs powered by DALI bus
• •
Automatic synchronization between the control locations EcoDesign Directive (EU) 2019/2020 compliant
•
Permanent memory dimming & tuning
• •
Operating temperature ¹: 0°C ~ +45°C, the humidity: 20% ~ 85% Five-year factory guarantee and lifetime technical support ¹
“¹” Detailed data please refer to the " PARAMETERS" table . Housing Properties • •
Casing: grey aluminum, and white polycarbonate Type of protection IP20 Bldg 3, Nangang 3rd Industrial Zone, Tangtou, Shiyan, Baoan, Shenzhen, CHINA 518108 Tel: + 86 755 29516789 Fax: +86 755 29516769Email: Sales@Kinglumi.com
1
DALI 2in1 Rotary Dimmer 046PDPE Series: F92002-04638301 DALI DT6 & DALI DT8 Tunable White Intended use • • • •
Switching Dimming Colour temperature tuning* (only works with DALI DT8 Tc) Memory
Protection The device provides the following protective functions: • Inrush current limitation through soft start • Electronic overload, over temperature protection • Electronic short-circuit protection • Integrated thermal fuse • Electronic over voltage
PARAMETERS MODEL
Input
Load
Protection
AC Voltage range Frequency range Max. Power DALI current draw Operating life Standby power No load power Memory function Mains surge capability(between L-N) DALI mode Max. Connected load at 25 °C Dimming Range Color temperature tuning range Control interface Output voltage Over current Short circuit Over voltage Over temperature No-load operation No damage at wrong mains voltage level Working Temp.
Environment
Others
Max. case(tc point) Temp. Working humidity Storage temp., humidity Connection-Screw terminals
F92002-04638301 230/240VAC 50/60Hz 3W 4mA 50,000 cycles <0.3W @ 230V <0.5W @ 230V yes 0.5KV DALI DT6, DALI DT8 Tc(Tunable White) 46 DALI ECGs / 92mA 0.1-100% 2000K ~ 10000K DA+, DA10-16.5V √ √ √ √ √ √ 0°C ~50°C At an ambient temperature above 35°C the maximum load will decrease by 15 % per 5°C 70°C 20%~85%RH -40°C ~80°C 2 Max. 2.5mm input cable cord
Bldg 3, Nangang 3rd Industrial Zone, Tangtou, Shiyan, Baoan, Shenzhen, CHINA 518108 Tel: + 86 755 29516789 Fax: +86 755 29516769Email: Sales@Kinglumi.com
2
DALI 2in1 Rotary Dimmer 046PDPE Series: F92002-04638301 DALI DT6 & DALI DT8 Tunable White Warranty years
5
Lifespan (hrs) @ ta=25°C
≧50,000H
Glow wire test Dimension L x W x H
850°C for 5S; 650°C for 30S 70.8X70.8X45.8mm 1pc per box(74x74x60mm); 10pcs per inner carton; 100pcs per master carton(40x34x36cm)
Packing
MAX. LOADS DERATING CURVE If you do not install the dimmer in a single, standard flush mounting box, the maximum permissible load is reduced due to the decreased heat dissipation: ■ When installing the dimmer in a wall made of gas concrete, wood, or plasterboard, the maximum connection load must be reduced by 20%. ■ The connected load must always be reduced when several dimmers are installed one below the other or when other heat sources cause additional heating. the maximum connected load must be reduced according to the diagram.
MECHANICAL The flush-mounted dimmer must only be installed in flush mounted boxes according to DIN 49073-1 or suitable surface mounted housings. Only be installed in dry interior rooms. Observe the currently valid regulations.
Bldg 3, Nangang 3rd Industrial Zone, Tangtou, Shiyan, Baoan, Shenzhen, CHINA 518108 Tel: + 86 755 29516789 Fax: +86 755 29516769Email: Sales@Kinglumi.com
3
DALI 2in1 Rotary Dimmer 046PDPE Series: F92002-04638301 DALI DT6 & DALI DT8 Tunable White
DIMMER AND COVERS
(1)Dimmer (2) Frame (2) ,(4)Not included
(3)Nut (4) Rotary knob
(5) Screw terminals
Installation For your safety Risk of death and fire due to electrical voltage of 230 V. 1. Work on the 230V supply system may only be performed by authorized electricians! 2. Disconnect the mains power supply prior to installation and/or disassembly! 3. Please read the mounting instructions carefully and keep them for future use. 4. Additional user information and information about planning is available at www.Kinglumi.com
Wiring Support both Master mode(powered by AC mains),and Slave mode(powered by DALI bus). 1. AC power input should only be connected if the dimmer is used as a Master. 2. Wiring cross section Max. 2.5 mm. 3. Total length power cable Max. 300 m. 4. Total length of DALI bus cable Max. 300 m. 5. For wiring diagram, please refer to the installation instrcution
Commissioning i.
Save switch-on brightness If the lighting is not always to be switched on with the same brightness, then this can be saved as a switch on brightness. Bldg 3, Nangang 3rd Industrial Zone, Tangtou, Shiyan, Baoan, Shenzhen, CHINA 518108 Tel: + 86 755 29516789 Fax: +86 755 29516769Email: Sales@Kinglumi.com
4
DALI 2in1 Rotary Dimmer 046PDPE Series: F92002-04638301 DALI DT6 & DALI DT8 Tunable White 1.Switch on light. 2.Set required switch-on brightness. 3.Press the rotary knob for longer than 10 seconds. The lighting briefly switches off-on-off and then on. The switch-on brightness is saved. ii.
Delete switch-on brightness 1.Switch the light off. 2.Press the rotary knob for longer than 10 seconds. The lighting briefly switches on-off and then on. The switch-on brightness has been deleted
PACKAGING Part Number
Dimension
Gross Weight
Net Weight
Qty/Carton
F92002-04638301
40x34x36cm
/
/
100
Environment! Consider the protection of the environment! Used electric and electronic devices must not be disposed of with domestic waste. The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot.
Bldg 3, Nangang 3rd Industrial Zone, Tangtou, Shiyan, Baoan, Shenzhen, CHINA 518108 Tel: + 86 755 29516789 Fax: +86 755 29516769Email: Sales@Kinglumi.com
5
DALI 2in1 Rotary Dimmer 046PDPE Series: F92002-04638301 DALI DT6 & DALI DT8 Tunable White VERSION #
#
MODIFICATIONS
1
Version 1
Date. 2021.10.09
2
3
4
5
6
7
8
9
10
11
12
Copyright 2019-2025 by Kinglumi Co., Ltd.(K&L) All rights reserved. The information in this document is subject to change without notice.
Bldg 3, Nangang 3rd Industrial Zone, Tangtou, Shiyan, Baoan, Shenzhen, CHINA 518108 Tel: + 86 755 29516789 Fax: +86 755 29516769Email: Sales@Kinglumi.com
6