TUNNEL
OPTIMIZED LIGHTING DISTRIBUTION FOR TUNNELS
IT’S TECHNICALLY SUPERIOR! Tunnel Lighting is the most technical and fundamentally broad one of all lighting applications. Beam directions, lux levels, luminance and illuminance levels, thresholds etc. becomes exceptionally important when it comes to tunnels. Due to the fact that optimum tunnel lighting is directly related to driver’s safety, from project to product design, many criteria have to be handled carefully to light up tunnels in the most adequate way. WE’RE EXPERIENCED! As Heper, we have a proud history over a dacade working in tunnel lighting applications. In the course of time, we have completed many significant tunnel projects successfully all around the world. In recent years, we have worked constantly to carry our success in conventional light source tunnel products to latest technology LEDs. DESIGNED TO RESIST TOUGH CONDITIONS! It is a fact that tunnels host a corrosive atmospheric condition and limited access. Therefore, high quality, low copper die-cast aluminum and stainless steel are used and all the developments have been made to make the product with the longest life possible. Also; Installation, dismantle and maintenance processes are as easy as it gets. IT’S ALL ABOUT SAFETY! Our tunnel luminaires meet the latest technology requirements and fundamentals in tunnel lighting for which the objective is to allow traffic to safely enter, pass through and exit the tunnel and do so without needing to reduce speed to identify objects and obstacles. It can also meet the different illumination needs for different zones in tunnels. Finally, it can be easily implemented with different type of control options to make sure the safety requirements are met for different times of the day.
TUNNEL LIGHTING PRINCIPLES ZONES TYPES
1 - Access zone The part of the open road in front of the tunnel portal in the approach direction, covering the distance over which an approaching driver is able to see tunnel entrance. The access zone begins at the stopping distance before of the entrance portal and it ends at the tunnel entrance portal.
3 - Transition zone The part of the tunnel starts from just after the threshold zone and ends at the beginning of interior zone. The lighting level in the transition zone is decreasing from the level at the end of the threshold zone to the level of the interior zone. Interior zone: the part of the tunnel after the transition zone till to the beginning of the exit zone.
2 - Threshold zone The first part of the tunnel, just after the entrance portal. The threshold zone starts either at the beginning of the tunnel or at the beginning of the daylight sunscreens when occurring. The length of the threshold zone is at least equal to the stopping distance.
4 - Interior zone The part of the tunnel after the transition zone till to the beginning of the exit zone.
L seq
L th
L tr
THRESHOLD TRANSITION ZONE LUMINANCE ZONE LUMINANCE THRESHOLD ZONE TRANSITION ZONE
EQUIVALENT VEILING LUMINANCE (ACCESS ZONE)
5 - Exit zone The exit zone begins at the end of the interior zone, ends at the exit portal of the tunnel.
L int
INTERIOR ZONE LUMINANCE INTERIOR ZONE
L ex
2 SSD
LUMINANCE IN THE EXIT ZONE LUMINANCE
L th Tunnel entrance Luminance
0.4 x L th
5 x Lth
L th
m SSD
ACCESS ZONE THRESHOLD ZONETRANSITION ZONE Luminance metre
SSD
1/2 SSD INTERIOR ZONE
EXIT ZONE
20m
SSD (Safe - Stopping - Distance)
TUNNEL LIGHTING PRINCIPLES DESIGN CRITERIA
Tunnel Tunnel is the structure over a roadway that restricts the normal daytime natural illumination of a roadway section such that the driver’s visual sensation is diminished. In order to classify changing lighting requirements along with the tunnel length, tunnel is evaluated in the form of sub interior zones: the access zone, the threshold zone, the transition zone, the interior zone, the exit zone and parting zone. Traffic Flow The number of vehicles passing a specific point in a stated time in stated direction(s). In tunnel design, peak hour traffic, vehicles per hour per lane, will be used.
Design Speed The design speed is the speed for which the tunnel is laid out. It is generally accepted that this speed is the maximum speed allowed on the access roads to the tunnel. Reference Point The reference point is in principle the point located in the centre of the approaching lanes, at a height of 1,5 m and at a distance from the entrance of the tunnel equal to the stopping distance (SD) at the design speed. Stopping Distance Stopping distance is the distance necessary to stop the vehicle moving at the speed in question in total safety. It comprises the distance covered during the reaction time and during the braking time.
DESIGN CRITERIA TUNNEL LIGHTING DISTRIBUTION TYPES
Symmetric lighting The lighting where the light equally falls on objects in directions with and against the traffic. Symmetric lighting is characterized by using luminaries that show a luminous intensity distribution that is symmetric in relation to the plane normal to the direction of the traffic.
Counter-beam lighting The lighting where the light falls on objects from an opposite direction to the traffic. Counter-beam lighting is characterized by using luminaries that show a luminous intensity distribution that is asymmetric in relation to the plane normal to the direction of the traffic, where the maximum luminous intensity is aimed against the direction of the traffic The term refers only to the direction of normal travel.
Pro-beam lighting The lighting where the light falls on objects in the same direction as the traffic. Pro-beam lighting is characterized by using luminaries that show a luminous intensity distribution that is asymmetric in relation to the where the maximum luminous intensity is aimed in the same direction as the direction of the traffic. 4
www.heperlighting.com
5
NOX STAINLESS STEEL DURABLE TUNNEL LIGHTING LUMINAIRE
With dozens of optical distribution options, there is no tunnel out there that our Nox cannot thrive in.
6
www.heperlighting.com
7
NOX SYMMETRIC - ASYMMETRIC TECHNICAL SPECIFICATIONS
APPLICATION AREAS • •
Tunnels Underpasses
GENERAL HIGHLIGHTS • • • • •
Various optics for different tunnel applications Operating temperature: -40˚C / +55˚C Easy installation and maintenance Exceptional thermal characteristics In compliance with EN 60598, EN 62722
ELECTRICAL PROPERTIES • • • • • • • • •
Drive current: 350mA, 525mA, 700mA Optimized PCB design Insulation class: CLASS I, CLASS II Energy class: A+ Power factor > 0.95 Input Voltage: 220V-240V / 110V-120V at 50Hz /60Hz Control Type: 1-10V, DALI, StepDIM, AstroDIM Constant Light Output (optional) Halogen free cabling
OPTICAL PROPERTIES •
Various lens arrangements for different zones and different installation areas • Homogenous light distribution • Reduced glare with special lenses with transmission > 95% • Power Chips • MacAdam Ellipse 3 / 5 • Lumen Output: 7200lm – 43000lm • Color Temperature: 3000K, 3500K, 4000K • CRI > 70 (4000K), CRI > 70 (3500K) CRI> 80 (3000K) • Lumen depreciation: L90B10 > 100000h (calculated) Photobiological safety: Risk Group 0 • Efficacy: 121 lm/W for 4000K at 700mA
BODY HOUSING & FINISH • • • • • •
Corrosion resistant high pressure die-cast aluminum housing Stainless steel glass frame (316 Ti/L) Electrostatic powder coating HM1 to HM6 standard colors with optional RAL codes Ingress protection: IP66 Impact protection: IK08
NOX SYMMETRIC INTERIOR LIGHTING Symmetric optic on cross plane for: 1. Single ot twin row arrangements 2. Rows in the corners for rectengular crosssections. 3- Single or muti lane traffic tunnels. 105˚
105˚
105˚
105˚
90˚
90˚
90˚
90˚
75˚
75˚ 200
60˚
45˚
15˚
320
300
400
480
400
45˚
45˚
640 800
600
700
960
700
0˚
30˚
15˚
0˚
C90 - C270
C90 - C270
C0 - C180
C90 - C270
500 600 700
30˚
15˚
0˚
468
600
265 355
400
40
265
68 40
400
cd/klm
C0 - C180
Goledo ME 8U0D
40
68 40 355
400
45˚
0˚
Goledo ME 4U4D
600
10
300
cd/klm
Goledo DWC
468
15˚
cd/klm
C0 - C180
Goledo DNW
30˚
200
60˚
500
600
cd/klm
C0 - C180
75˚ 200
60˚
300
500
30˚
75˚ 160
60˚
C90 - C270
IK
08
IP
66
CODE
LT1010.761
LT1010.762
LT1010.763
LT1010.764
LT1010.765
www.heperlighting.com
EN 60598
DESCRIPTION
NOX Sym 32 LED
NOX Sym 40 LED
NOX Sym 64 LED
NOX Sym 80 LED
NOX Sym 160 LED
CCT
DRIVE CURRENT
LUMEN OUTPUT
POWER
3000K
350mA
4100 lm
36W
3000K
525mA
5600 lm
54W
3000K
700mA
7200 lm
70W
3500K
350mA
4550 lm
36W
3500K
525mA
6200 lm
54W
3500K
700mA
8000 lm
70W
4000K
350mA
4800 lm
36W
4000K
525mA
6600 lm
54W
4000K
700mA
8500 lm
70W
3000K
350mA
4900 lm
46W
3000K
525mA
6700 lm
70W
3000K
700mA
8600 lm
90W
3500K
350mA
5500 lm
46W
3500K
525mA
7500 lm
70W
3500K
700mA
9600 lm
90W
4000K
350mA
5800 lm
46W
4000K
525mA
8000 lm
70W
4000K
700mA
10250 lm
90W
3000K
350mA
8200 lm
70W
3000K
525mA
11200 lm
105W
3000K
700mA
14400 lm
136W
3500K
350mA
9200 lm
70W
3500K
525mA
12500 lm
105W
3500K
700mA
16000 lm
136W
4000K
350mA
9600 lm
70W
4000K
525mA
13300 lm
105W
4000K
700mA
17000 lm
136W
3000K
350mA
10300 lm
90W
3000K
525mA
14000 lm
131W
3000K
700mA
18100 lm
170W
3500K
350mA
11600 lm
90W
3500K
525mA
15800 lm
131W
3500K
700mA
20200 lm
170W
4000K
350mA
12100 lm
90W
4000K
525mA
16800 lm
131W
4000K
700mA
21500 lm
170W
3000K
350mA
20600 lm
180W
3000K
525mA
28000 lm
262W
3000K
700mA
36200 lm
340W
3500K
350mA
23200 lm
180W
3500K
525mA
31600 lm
262W
3500K
700mA
40400 lm
340W
4000K
350mA
24200 lm
180W
4000K
525mA
33600 lm
262W
4000K
700mA
43000 lm
340W
11
NOX ASYMMETRIC ENTRANCE LIGHTING Asymmetric counter-beam optic symmetric on cross plane. This optic optimises the lighting distribution according to the tunnel and pavements width. Typical applications: 1. Single ot twin row arrangements 2. Rows in the corners for rectengular crosssections. 3- Single or muti lane traffic tunnels. 105˚ 90˚ 75˚ 1000
60˚
1500 2000
45˚
2500 3000 3500
15˚
30˚
C0 - C180
0˚
cd/klm
C90 - C270
468
468
Goledo Asym
600
355
355
40
68 40
265
600
400
40
265
68 40
400
12
IK
08
IP
66
CODE
LT1010.761
LT1010.762
LT1010.763
LT1010.764
LT1010.765
www.heperlighting.com
EN 60598
DESCRIPTION
NOX Asym 32 LED
NOX Asym 40 LED
NOX Asym 64 LED
NOX Asym 80 LED
NOX Asym 160 LED
CCT
DRIVE CURRENT
LUMEN OUTPUT
POWER
3000K
350mA
4050 lm
36W
3000K
525mA
5550 lm
54W
3000K
700mA
7150 lm
70W
3500K
350mA
4500 lm
36W
3500K
525mA
6150 lm
54W
3500K
700mA
7950 lm
70W
4000K
350mA
4750 lm
36W
4000K
525mA
6550 lm
54W
4000K
700mA
8450 lm
70W
3000K
350mA
4900 lm
46W
3000K
525mA
6700 lm
70W
3000K
700mA
8600 lm
90W
3500K
350mA
5500 lm
46W
3500K
525mA
7500 lm
70W
3500K
700mA
9600 lm
90W
4000K
350mA
5800 lm
46W
4000K
525mA
8000 lm
70W
4000K
700mA
10250 lm
90W
3000K
350mA
8200 lm
70W
3000K
525mA
11200 lm
105W
3000K
700mA
14400 lm
136W
3500K
350mA
9200 lm
70W
3500K
525mA
12500 lm
105W
3500K
700mA
16000 lm
136W
4000K
350mA
9600 lm
70W
4000K
525mA
13300 lm
105W
4000K
700mA
17000 lm
136W
3000K
350mA
10300 lm
90W
3000K
525mA
14000 lm
131W
3000K
700mA
18100 lm
170W
3500K
350mA
11600 lm
90W
3500K
525mA
15800 lm
131W
3500K
700mA
20200 lm
170W
4000K
350mA
12100 lm
90W
4000K
525mA
16800 lm
131W
4000K
700mA
21500 lm
170W
3000K
350mA
20600 lm
180W
3000K
525mA
28000 lm
262W
3000K
700mA
36200 lm
340W
3500K
350mA
23200 lm
180W
3500K
525mA
31600 lm
262W
3500K
700mA
40400 lm
340W
4000K
350mA
24200 lm
180W
4000K
525mA
33600 lm
262W
4000K
700mA
43000 lm
340W
13
14
www.heperlighting.com
15
ETA CONTINUOUS LINE ALUMINIUM EXTRUSION
With dozens of optical distribution options, there is no tunnel out there that our Eta cannot thrive in.
16
www.heperlighting.com
17
ETA SYMMETRIC - ETA ASYMMETRIC TECHNICAL SPECIFICATIONS
APPLICATION AREAS • •
Tunnels Underpasses
GENERAL HIGHLIGHTS • • • • •
Corrosion resistant extruded aluminum housing Various optics for different tunnel applications Operating temperature: -40˚C / +55˚C Compatible with different width of cable trays In compliance with EN 60598, EN 6272
ELECTRICAL PROPERTIES • • • • • • • • •
Drive current: 350mA, 525mA, 700mA Optimized PCB design Insulation class: CLASS I, CLASS II Energy class: A+ Power factor > 0.95 Input Voltage: 220V-240V / 110V-120V at 50Hz /60Hz Control Type: 1-10V, DALI, StepDIM, AstroDIM Constant Light Output (optional) Halogen free cabling
OPTICAL PROPERTIES •
Various lens arrangements for different zones and different installation areas • Homogenous light distribution • Reduced glare with special lenses with transmission > 95% • Power Chips • MacAdam Ellipse 3 / 5 • Lumen Output: 10000lm – 65000lm • Color Temperature: 3000K, 4000K • CRI > 70 (4000K), CRI> 80 (3000K) • Lumen depreciation: L90B10 > 100000h (calculated) Photobiological safety: Risk Group 0 • Efficacy: 125 lm/W for 4000K at 700mA
BODY HOUSING & FINISH • • • • • • • •
Galvanic corrosion protection for metal contacts Easy installation for cable trays with hinged connection Toolless maintenance with hinged cover High flux and power outputs on tunnels Electrostatic powder coating HM1 to HM6 standard colors with optional RAL codes Ingress protection: IP66 Impact protection: IK08
ETA ASYMMETRIC ENTRANCE LIGHTING Asymmetric counter-beam optic symmetric on cross plane. This optic optimises the lighting distribution according to the tunnel and pavements width. Typical applications: 1. Single ot twin row arrangements 2. Rows in the corners for rectengular crosssections. 3- Single or muti lane traffic tunnels. 105˚ 90˚ 75˚ 1000
60˚
1500 2000
45˚
2500 3000 3500
30˚
15˚
0˚ cd/klm
C0 - C180
C90 - C270
225
335
Goledo Asym
56
280
512
20
IK
08
IP
66
CODE
LT2043.761
LT2043.762
LT2043.763
LT2043.764
www.heperlighting.com
EN 60598
DESCRIPTION
ETA Asym 32 LED
ETA Asym 40 LED
ETA Asym 64 LED
ETA Asym 80 LED
CCT
DRIVE CURRENT
LUMEN OUTPUT
POWER
3000K
350mA
10300
90
3000K
525mA
14000
131
3000K
700mA
18100
170
4000K
350mA
12100
90
4000K
525mA
16800
131
4000K
700mA
21500
170
3000K
350mA
10300
90
3000K
525mA
14000
131
3000K
700mA
18100
170
4000K
350mA
12100
90
4000K
525mA
16800
131
4000K
700mA
21500
170
3000K
350mA
10300
90
3000K
525mA
14000
131
3000K
700mA
18100
170
4000K
350mA
12100
90
4000K
525mA
16800
131
4000K
700mA
21500
170
3000K
350mA
10300
90
3000K
525mA
14000
131
3000K
700mA
18100
170
4000K
350mA
12100
90
4000K
525mA
16800
131
4000K
700mA
21500
170
21
ETA SYMMETRIC INTERIOR LIGHTING Symmetric optic on cross plane for 1. Single ot twin row arrangements 2. Rows in the corners for rectengular crosssections. 3- Single or muti lane traffic tunnels.
105˚
105˚
105˚
105˚
90˚
90˚
90˚
90˚
75˚
75˚ 200
60˚
45˚
30˚
320
300
400
480
400
45˚
800
600
700
960
700
0˚
15˚
30˚
0˚
C0 - C180
C90 - C270
C0 - C180
Goledo DWC
280 56
300 400
45˚
500 600 700
0˚
30˚
15˚
0˚
cd/klm
Goledo ME 4U4D
512
22
15˚
cd/klm
225
C90 - C270
30˚
200
60˚
500
600
335
Goledo DNW
45˚
640
cd/klm
C0 - C180
75˚ 200
60˚
300
500
15˚
75˚ 160
60˚
C90 - C270
cd/klm
C0 - C180
Goledo ME 8U0D
C90 - C270
IK
08
IP
66
CODE
LT2043.761
LT2043.762
LT2043.763
LT2043.764
www.heperlighting.com
EN 60598
DESCRIPTION
ETA Sym 32 LED
ETA Sym 40 LED
ETA Sym 64 LED
ETA Sym 80 LED
CCT
DRIVE CURRENT
LUMEN OUTPUT
POWER
3000K
350mA
4100 lm
36W
3000K
525mA
5600 lm
54W
3000K
700mA
7200 lm
70W
4000K
350mA
4800 lm
36W
4000K
525mA
6600 lm
54W
4000K
700mA
8500 lm
70W
3000K
350mA
4900 lm
46W
3000K
525mA
6700 lm
70W
3000K
700mA
8600 lm
90W
4000K
350mA
5800 lm
46W
4000K
525mA
8000 lm
70W
4000K
700mA
10250 lm
90W
3000K
350mA
8200 lm
70W
3000K
525mA
11200 lm
105W
3000K
700mA
14400 lm
136W
4000K
350mA
9600 lm
70W
4000K
525mA
13300 lm
105W
4000K
700mA
17000 lm
136W
3000K
350mA
10300 lm
90W
3000K
525mA
14000 lm
131W
3000K
700mA
18100 lm
170W
4000K
350mA
12100 lm
90W
4000K
525mA
16800 lm
131W
4000K
700mA
21500 lm
170W
23
24
www.heperlighting.com
25
GOLEDO STATE OF THE ART TUNNEL LIGHTING LUMINAIRE
With dozens of optical distribution options, there is no tunnel out there that our Goledo cannot thrive in.
26
www.heperlighting.com
27
GOLEDO TECHNICAL SPECIFICATIONS
GENERAL HIGHLIGHTS •
Various optics for different tunnel and underpass applications • Operating temperature: -40°C / +55°C • Easy installation and maintenance • Direct cable tray mountable • Silicon gasket • Unique no-carry mounting and maintenance system • Exceptional thermal characteristics • In compliance with EN 60598, EN 62722 • ENEC and UL certified
ELECTRICAL PROPERTIES • • • • • •
Drive current: 350mA, 525mA, 700mA Optimized PCB design Insulation class: CLASS I, CLASS II Energy class: A+ Power factor > 0.95 Input Voltage: 220V - 240V / 110V - 120V (optional) at 50Hz /60Hz • Control Type: 1-10V, DALI, StepDIM, AstroDIM • Halogen free cabling
OPTICAL PROPERTIES •
Various lens arrangements for different zones and different installation areas • Homogenous light distribution • Reduced glare with special lenses with transmission > 95% • Power Chips • MacAdam Ellipse 3 • Lumen output (absolute photometry): 7200lm - 21500lm • Color Temperature: 3000K, 3500K, 4000K • CRI > 70 (4000K), CRI > 70 (3500K) CRI > 80 (3000K) • Lumen depreciation: L90B10 > 118000h • Photobiological safety: Risk Group 1 • Efficacy (absolute photometry): 127 lm/W for 4000K at 700mA
BODY HOUSING & FINISH • • • • •
Corrosion resistant die-cast aluminum housing Electrostatic powder coating RAL 7035 standard color with optional RAL codes Ingress protection: IP66 Impact protection: IK08
EXTRAS • • • • •
Constant Light Output Programmable driver for different scenarios Marine grade coating Different light distribution options Chromate coating prior to paint
GOLEDO ASYMMETRIC ENTRANCE LIGHTING Asymmetric counter-beam optic symmetric on cross plane. This optic optimises the lighting distribution according to the tunnel and pavements width. Typical applications: 1. Single ot twin row arrangements 2. Rows in the corners for rectengular crosssections. 3- Single or muti lane traffic tunnels.
105˚ 90˚ 75˚ 1000
60˚
1500 2000
45˚
2500 3000 3500
30˚
15˚
0˚ cd/klm
C0 - C180
C90 - C270
Goledo Asym
293 Standard bracket
168
250
700
Slide mount bracket
216
700
No-carry slide mount system
30
250
IK
08
IP
66
CODE
LT2037.761
LT2037.765
LT2037.767
LT2037.766
www.heperlighting.com
EN 60598
DESCRIPTION
Goledo T Asym 32 LED
Goledo T Asym 40 LED
Goledo T Asym 64 LED
Goledo T Asym 80 LED
CCT
DRIVE CURRENT
LUMEN OUTPUT
POWER
3000K
350mA
4050 lm
36W
3000K
525mA
5550 lm
54W
3000K
700mA
7150 lm
70W
4000K
350mA
4750 lm
36W
4000K
525mA
6550 lm
54W
4000K
700mA
8450 lm
70W
3000K
350mA
4050 lm
36W
3000K
525mA
5550 lm
54W
3000K
700mA
7150 lm
70W
4000K
350mA
4750 lm
36W
4000K
525mA
6550 lm
54W
4000K
700mA
8450 lm
70W
3000K
350mA
8200 lm
70W
3000K
525mA
11200 lm
105W
3000K
700mA
14400 lm
136W
4000K
350mA
9600 lm
70W
4000K
525mA
13300 lm
105W
4000K
700mA
17000 lm
136W
3000K
350mA
10300 lm
90W
3000K
525mA
14000 lm
131W
3000K
700mA
18100 lm
170W
4000K
350mA
12100 lm
90W
4000K
525mA
16800 lm
131W
4000K
700mA
21500 lm
170W
31
GOLEDO SYMMETRIC INTERIOR LIGHTING Symmetric optic on cross plane for: 1. Single ot twin row arrangements 2. Rows in the corners for rectengular crosssections. 3- Single or muti lane traffic tunnels.
105˚
105˚
90˚
90˚
75˚
75˚ 200
60˚
45˚
293
160
60˚
300
320
400
480
45˚
500
800
700
15˚
960
0˚
30˚
15˚
cd/klm
C90 - C270
C0 - C180
Goledo DNW
Goledo DWC
105˚
105˚
90˚
90˚
75˚
700
200
60˚
300
300
400
45˚
400
45˚
500
500
600
15˚
700
0˚
30˚
15˚
0˚
cd/klm
C0 - C180
Goledo ME 4U4D
32
C90 - C270
No-carry slide mount system
600
700
30˚
C90 - C270
75˚ 200
60˚
cd/klm
C0 - C180
Goledo ME 8U0D
Slide mount bracket
216
0˚
cd/klm
C0 - C180
250
700
640
600
30˚
Standard bracket
168
C90 - C270
250
IK
08
IP
66
CODE
LT2037.761
LT2037.765
LT2037.767
LT2037.766
www.heperlighting.com
EN 60598
DESCRIPTION
Goledo T Sym 32 LED
Goledo T Sym 40 LED
Goledo T Sym 64 LED
Goledo T Sym 80 LED
CCT
DRIVE CURRENT
LUMEN OUTPUT
POWER
3000K
350mA
4100 lm
36W
3000K
525mA
5600 lm
54W
3000K
700mA
7200 lm
70W
4000K
350mA
4800 lm
36W
4000K
525mA
6600 lm
54W
4000K
700mA
8500 lm
70W
3000K
350mA
4900 lm
46W
3000K
525mA
6700 lm
70W
3000K
700mA
8600 lm
90W
4000K
350mA
5800 lm
46W
4000K
525mA
8000 lm
70W
4000K
700mA
10250 lm
90W
3000K
350mA
8200 lm
70W
3000K
525mA
11200 lm
105W
3000K
700mA
14400 lm
136W
4000K
350mA
9600 lm
70W
4000K
525mA
13300 lm
105W
4000K
700mA
17000 lm
136W
3000K
350mA
10300 lm
90W
3000K
525mA
14000 lm
131W
3000K
700mA
18100 lm
170W
4000K
350mA
12100 lm
90W
4000K
525mA
16800 lm
131W
4000K
700mA
21500 lm
170W
33
2020-HPR-020319.54 Printed on 27.02.2020 *Heper withholds the right to make modifications on declared information without prior notice. HPR Pazarlama A.Ş. 1. Organize Sanayi Bölgesi Uygurlar Cad. No:1 Sincan (06935), Ankara, Türkiye T: +90 312 267 54 30 (pbx) F: +90 312 267 54 31 E: info@heperlighting.com W: www.heperlighting.com