MY WO RK igor ruiz apilanez
Haz Restaurant
6 Mincing Lane, London Sophisticated and opulent Turkish restaurant in the heart of the City, created with the highest quality materials and the best craftsmanship. Project scope: • Liaisong with Client and Design Agency at design stage • Drawing Coordination • Obtainment of Statutory Approvals • Pre-Construction Project Management - Programme - Tender process and contract award - Consultant liaison and appointments - Contract negotiation • On-Site Project Management - Site inspection - Cost & Progress reports - Meetings, agendas and minutes - Problem solving and risk mitigation • Post Completion Snagging and Defects - Snagging review - Final account negotiation - O&M infomation compilation - Post completion defects meetings • Cost Reporting and Schedules Project Value: circa £800k
AXOR / Hansgrohe
Clerkenwell Road, London The Water Studio, with its working water cascade and the 4D-mapped animated artwork is not just a showroom but a place about creating new experiences. Project scope: • Liaisong with Client and Design Agency at design stage • Construction drawings and Bespoke joinery drawings • Drawings for all relevant Statutory Approvals • Drawing Coordination • Pre-Construction Project Management - Programme - Tender process and contract award - Consultant liaison and appointments - Contract negotiation • On-Site Project Management - Site inspection - Cost & Progress reports - Meetings, agendas and minutes - Problem solving and risk mitigation • Post Completion Snagging and Defects - Snagging review - Final account negotiation - O&M infomation compilation - Post completion defects meetings • Cost Reporting and Schedules Project Value: circa £500k
EXISTING CONCRETE WALL
BOX FRAME FITTED TO RECESS ON MOVING RUNNERS ALLOWING SERVICE ACCESS TO CISTERN
NEW 100 X 50mm TIMBER STUD WALL
CONCEALED CISTERN
RECESSED LED SPOTLIGHT AS PER LIGHTING SUPPLIER'S SCHEDULE
FLUSH MOUNTED MIRROR WALL HUNG WC TOILET ROLL HOLDER
WBP PLY BOX FRAME TO MOUNT TV RECESSED LED SPOTLIGHT AS PER LIGHTING SUPPLIER'S SCHEDULE
30
50 X 70mm ACOUSTIC METAL SECTION STUD PARTITION ACOUSTIC INSULATION
TV - - AS PER SPEC REF. MIRROR GLASS FIXED TO TV AS PER SPEC REF
CONCEALED LED STRIP IN CEILING COFFER - AS PER LIGHTING SUPPLIER'S SCHEDULE
A
100 X 50mm TIMBER STUD WALL
RMS001
B
C
RMS001
RMS001
20
SURFACE MOUNTED BASIN
MIRROR
PENDANT LIGHTS AS PER LIGHTING SUPPLIER'S SCHEDULE
D
50
RMS001
SOLID OAK COUNTER TOP ON STEEL GALLOWS BRACKET
5
12
RECESSED EXTRACT FAN
MARBLE WALL FINISH AS PER SPEC REF. TILE ADHESIVE AS PER SPEC REF.
100
PLAN
20
825
25
150
MARBLE WALL FINISH
WALL BUILD-UP: 70 X 50mm MET SEC STUD 50mm ACOUSTIC INSULATION 2No. 12.5mm AQUAPANEL 7.5mm TILE ADHESIVE DAB 3mm LARGE FORMAT TILE
WALL HUNG WC
'L' PROFILE STEEL CHANNEL SHADOW GAP
TOILET ROLL HOLDER
SECTION A-A
SCALE 1:5
SCALE 1:20
Interiors
www.mailendesign.com
Urban Design
info@mailendesign.com
Report all drawing errors, omissions and discrepancies to the architect.
0
500mm
REV DATE 1 2
07.08.15 18.09.15
NOTES
INT
ISSUED FOR TENDER ISSUED FOR CONSTRUCTION
IR IR
TAP
CLIENT DIRECT GEBERIT FLUSH PLATE SIGMA 10 FOR DUEL FLUSH CLIENT DIRECT
Scale 1:5 1m
CROSS SECTION A-A WORKING WATER DISPLAY - G.F.
2m
DRAWING NO.
Scale 1:20
MAILEN DESIGN
AXOR - HANSGROHE 12-16 CLERKENWELL ROAD LONDON, EC1
DRAWING TITLE
0
Room Sets
PROJECT TITLE
15013_CON_FF_008
MARBLE WALL FINISH
FLUSH PLATE WASTE TRAP
Working Water Cascade - Fixtures & Fittings
LOW-LEVEL WALL TILE HIGH LEVEL WALL TILE
Architecture
DRAWN IR
Interiors
Urban Design
info@mailendesign.com
www.mailendesign.com
CHECKED
MARBLE SKIRTING FLOOR FINISH
'L' PROFILE STEEL CHANNEL SHADOW GAP
KERLITE : DCK08 CENDRE BUXY 3000 x 1000 mm FORMAT GROUT - MAPEI 114 ANTRACITE KERLITE : DCKP08 CENDRE BUXY 1000x49 mm FORMAT CUT ON SITE GROUT - MAPEI 114 ANTRACITE JEWELS BLACKGOLD JW11 NATURAL / HONED FINISH GROUT - MAPEI 114 ANTRACITE JEWELS BLACKGOLD JW11 NATURAL / HONED FINISH GROUT - MAPEI 114 ANTRACITE JEWELS BLACKGOLD JW11 NATURAL / HONED FINISH GROUT - MAPEI 114 ANTRACITE
SCALE 1:20@A1
SCALE 1:20@A1
CEILING FINISH
MATERIALS: DURASTYLE TOILET WALL REF. 255909 DURAVIT - VERO 450 x 350 mm GROUND BASE ONE TAP HOLE GEBERIT DUOFIX FRAME H112 WITH SIGMA 12 CISTERN
WC
WASTE BIN
ELEVATION D
ELEVATION C
SCALE 1:20@A1
SANITARYWARE:
CISTERN BRASSWARE:
SINK AND TIMBER COUNTERTOP ON GALLOWS BRACKET
MARBLE SKIRTING
ELEVATION B
SCALE 1:20@A1
200
WALL BUILD-UP: 100 X 50mm TIMBER STUD 15mm WBP PLYWOOD 12.5mm AQUAPANEL 6mm TILE ADHESIVE 20mm MARBLE SLAB[>50kg/m.sq]
MARBLE SKIRTING
ELEVATION A
BASIN
Architecture
WALL BUILD-UP: 70 X 50mm MET SEC STUD 50mm ACOUSTIC INSULATION 18mm WBP PLYWOOD 2No. 12.5mm AQUAPANEL 7.5mm TILE ADHESIVE 3mm LARGE FORMAT TILE
WALL TILE AND TILE ADHESIVE
WALL TILE AND TILE ADHESIVE ON DOUBLE LAYER AQUAPANEL
800
300
40
780
1000
HAND DRIER
E
125
All areas are approximate and measured off preliminary drawings. They relate to the likely area of the building at the current state of the design and using the stated option either in accordance to client standards or the RICS Code of Measuring Practice, 6th Edition, RICS/ISVA. Any decisions to be made on the basis of these predictions, whether as to project viability, pre-letting, lease agreements or the like should include due allowances for the increases and decreases inherent in the design development and building process.
GRAB RAIL 1100 mm TO CENTER OF RAIL
RMS001
FLUSH PLATE
125
The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
DOUBLE AQUAPANEL ON WBP
ALARM RESET BUTTON
3 mm STEEL TRIM
WALL BUILD UP
MISCELLANEOUS
70 X 50mm MET SEC STUD KNAUF ACOUSTIC 'C' STUDS - OR SIMILAR ACOUSTIC INSULATION 50mm KNAUF EARTHWOOL ROLL - OR SIMILAR WBP 18mm & 15mm WBP BEHIND TILE BACKER BOARD ON SOME WALLS TILE BACKER BOARD 12.5mm AQUAPANEL OR SIMILAR
FIXED VERTICAL GRAB RAIL ALLGOOD - HOLT RANGE (CLIENT CLIENT) HORIZONTAL GRAB RAIL ALLGOOD - HOLT RANGE (CLIENT CLIENT) HAND DRIER DYSON AIRBLADE 'V'
SPECIFICATION
MAILEN DESIGN
FLUSH MOUNTED MIRROR WALL
WALL TILE AND TILE ADHESIVE
3 mm STEEL TRIM
MARBLE SKIRTING TO BE FLUSH WITH FINISHED WALL
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement.
WALL TILE AND TILE ADHESIVE DOOR PAINTED
FLUSH MOUNTED MDF SHELVING UNIT RECESSED INTO WALL
FLUSH MOUNTED MIRROR WALL
GLASS SHELF ON STEEL DOWEL
PLASTERBOARD CEILING COFFER SKIMMED AND PAINTED WALL BUILD-UP: 70 X 50mm MET SEC STUD 18mm WBP PLYWOOD 2No. 12.5mm AQUAPANEL 4.5mm MIRROR ADHESIVE 6mm MIRROR GLASS
ALARM PULL CORD WITH TWO RED BANGLES (100 mm & 900 mm AFFL)
GLASS SHELF ON STEEL DOWEL WALL TILE AND TILE ADHESIVE FLUSH MOUNTED MDF SHELVING UNIT RECESSED INTO WALL
SCALE 1:5
200
WALL BUILD-UP: 100 X 50mm TIMBER STUD 18mm WBP PLYWOOD 2No. 12.5mm AQUAPANEL 4.5mm MIRROR ADHESIVE 6mm MIRROR GLASS
RECESSED LED SPOTLIGHT RECESSED EXTRACT FAN
25
Do not scale from drawing.
SCALE 1:2@A1
SCALE 1:20@A1
WALL BUILD-UP: 70 X 50mm MET SEC STUD 50mm ACOUSTIC INSULATION 2No. 12.5mm AQUAPANEL 7.5mm TILE ADHESIVE DAB 3mm SMALL FORMAT TILE
2393
2368
625
20
150
1000
DOUBLE FLUSH - FLUSH PLATE AS PER SPEC REF.
E_ DETAIL
FLOORING PLAN
SCALE 1:20@A1
WALL BUILD-UP: 70 X 50mm MET SEC STUD 50mm ACOUSTIC INSULATION 2No. 12.5mm AQUAPANEL 7.5mm TILE ADHESIVE DAB 3mm LARGE FORMAT TILE
2863
1368
REFLECTED CEILING PLAN
SCALE 1:20@A1
50 5
12
PLASTERBOARD CEILING COFFER SKIMMED AND PAINTED
800
5 mm TRANSITION TRIM BETWEEN DIFFERENT FLOORS
FULL TILE START POINT
HANSGROHE
WBP FIXED TO TIMBER STUD AS PER SPEC REF.
CONCEALED CISTERN AS PER SPEC REF.
800
AXOR
12.5mm AQUAPANEL AS PER SPEC REF.
BLACK MARBLE TILE 600 mm x 600 mm FORMAT
CEILING COFFER OVER
FLOOR SLAB NOTCHED TO TAKE NEW FLOOR TILE WITH FLUSH TRANSITION FROM EXISTING FFL
SCALE 1:5
600
100 X 50mm TIMBER STUD WALL
3 mm MAX GROUT
RECESSED LED SPOTLIGHT AS PER LIGHTING SUPPLIER'S SCHEDULE
WALL MOUNTED HAND DRIER CEILING COFFER OVER
RAL 9010 - PURE WHITE
DOOR FINISH
PAINTED - XXXXXXXXXXX
MIRROR WALL FINISH
6MM MIRROR GLASS
TV MIRROR GLASS
'PRODISPLAY' MIRROR GLASS 6mm WITH NON-ACTIVE AREA COATING 18mm MDF NICHE SHELVING UNIT - PAINTED COLOUR TBC 10 X 10mm CROME BLACK C CHANNEL SHADOW BEAD 30mm SOLID LIMED OAK
MDF SHELVING NICHE 'C' CHANNEL BEAD TIMBER COUNTER TOP GLASS SHELVES
LIGHTING
TOILET ROLL HOLDER TOILET BRUSH WASTE BIN TV SLIDING TRACKS
ALLGOOD - HOLT RANGE (CLIENT CLIENT) ALLGOOD - HOLT RANGE (CLIENT CLIENT) ALLGOOD - HOLT RANGE (CLIENT CLIENT) BY CONTRACTOR
RECESSED SPOTLIGHT 12.4W ADJ. WHITE LED SPOT LIGHT C/W 1-10V DRIVER AND 3,000K LEDS PENDANT LIGHT BOCCI 14.1 - 1.5W CAST GLASS SPHERE PENDANT C/W WARM WHITE LEDS L.E.D STRIP LIGHT RECESSED LINEAR ALUMINIUM EXTRUSION C/W OPAL DIFFUSER, 1-10V DRIVER AND 3,000K LEDS TV OMITTED
6mm GLASS SHELF ON SS DOWELS
Do not scale from drawing. The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement.
REV
DATE
NOTES
1 2 3 4
07.08.15 19.08.15 24.08.15 04.09.15
ISSUED FOR TENDER REV. 2 - LOCATION OF HAND DRYER UPDATED ISSUED FOR BUILDING REGS APPROVAL ISSUED FOR CONSTRUCTION
INT IR IR IR IR
PROJECT TITLE AXOR - HANSGROHE 12-16 CLERKENWELL ROAD LONDON, EC1 DRAWN TM CHECKED BMA SCALE 1:20 @ A1 REVISION 4
DRAWING TITLE PROPOSED GROUND FLOOR WC
The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing. All areas are approximate and measured off preliminary drawings. They relate to the likely area of the building at the current state of the design and using the stated option either in accordance to client standards or the RICS Code of Measuring Practice, 6th Edition, RICS/ISVA. Any decisions to be made on the basis of these predictions, whether as to project viability, pre-letting, lease agreements or the like should include due allowances for the increases and decreases inherent in the design development and building process.
DRAWING NO. 15013_TEN_RMS_001
Report all drawing errors, omissions and discrepancies to the architect.
BM
SCALE 1:20 / 1:5 @ A3
REVISION 2
720
850
EQ.
HDMI HDMI
1080 720
50
980
50
600
50
720
50
50
TV
900
600
EQ.
50
360
1800
PLAN
ELEVATION A
SCALE 1:20
TV
TV
TV
ELEVATION B
SCALE 1:20
SCALE 1:20
BT
COMMS CABINET
720
360
250 50
50
250
250
TV
TV
900
850
900
900
TV HDMI
850
375
TV
TV
375
TV
480
50
1080 PROPOSED GROUND FLOOR PLAN
600
720
SCALE 1:50
ELEVATION C
ELEVATION D
SCALE 1:20
Electrical Plan - GA Plans
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement.
Architecture
Interiors
www.mailendesign.com
Urban Design
info@mailendesign.com
BT
The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
Report all drawing errors, omissions and discrepancies to the architect.
DATE
NOTES
INT
1 2
07.08.15 28.08.15 02.10.15 23.10.15
ISSUED FOR TENDER REV. 2 - FLOOR BOX'S ELECTRICAL REQUIREMENT UPDATED FOLLOWING HANSGROHE IT COMMENTS ISSUED FOR CONSTRUCTION REV. 4 - UPDATED FOLLOWING SITE MEETING COMMENTS ON 22.10.2015
IR IR
3 4
REV
Do not scale from drawing.
All areas are approximate and measured off preliminary drawings. They relate to the likely area of the building at the current state of the design and using the stated option either in accordance to client standards or the RICS Code of Measuring Practice, 6th Edition, RICS/ISVA. Any decisions to be made on the basis of these predictions, whether as to project viability, pre-letting, lease agreements or the like should include due allowances for the increases and decreases inherent in the design development and building process.
600
1800
PROPOSED BASEMENT PLAN
SCALE 1:50
MAILEN DESIGN
50 50
50
TV
TV
TV
0
Scale 1:50
1m
2m
3m
4m
5m
IR IR
Bespoke Joinery Do not scale from drawing.
PROJECT TITLE AXOR - HANSGROHE 12-16 CLERKENWELL ROAD LONDON, EC1 DRAWING TITLE PROPOSED ELECTRICAL AND SMALL POWER PLANS DRAWING NO. 15013_TEN_GA_007
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement.
DRAWN IR CHECKED BM SCALE 1:50 @A1 REVISION 4
MAILEN DESIGN Architecture
Interiors
www.mailendesign.com
SECTION E
SCALE 1:20
Urban Design
info@mailendesign.com
SCALE 1:20
REV DATE 1
NOTE: UNIT TO BE ON CASTORS. JOINERY CONTRACTOR TO ADVISE ON MINIMUM CASTOR SIZE AND MINIMUM GAP BETWEEN FINISHED FLOOR AND JOINERY UNIT. DESIRED GAP TO BE 20-30 mm
All areas are approximate and measured off preliminary drawings. They relate to the likely area of the building at the current state of the design and using the stated option either in accordance to client standards or the RICS Code of Measuring Practice, 6th Edition, RICS/ISVA. Any decisions to be made on the basis of these predictions, whether as to project viability, pre-letting, lease agreements or the like should include due allowances for the increases and decreases inherent in the design development and building process. Report all drawing errors, omissions and discrepancies to the architect.
25.09.15
NOTES
ISSUED FOR TENDER -
INT IR
PROJECT TITLE
AXOR- HANSGROHE 12-16 CLERKENWELL ROAD LONDON, EC1
DRAWING TITLE
The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
0
Scale 1:20
1m
2m
DRAWN IR
BASEMENT FLOOR MID FLOOR UNITS CHECKED PAGE 2 BM
DRAWING NO. 15013_TEN_JN_008
SCALE 1:20 @ A3
REVISION 1
550
50
50
670
750
900
EQ.
200
250
50
50
50
2450
3000
2650
2750
50 50
290
1000
3160
750
50
50
1300
1050
EQ.
SCALE 1:20
3120
PROPOSED SECTION B-B
SCALE 1:20
1050
PROPOSED SECTION A-A
2940
SCALE 1:20
3160
PROPOSED SHOP FRONT - ELEVATION
PROPOSED LONG SECTION A-A
900
1650
SCALE 1:50
A
1533
50 150
900
1633
150 50
2088
1200
50
2188
B
A
GA_012
SCALE 1:20
Do not scale from drawing.
MAILEN DESIGN
GA_008
50
50 50
PROPOSED SHOP FRONT - PLAN
GA_012
SCALE BAR
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement.
0
The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
Scale 1:20
All areas are approximate and measured off preliminary drawings. They relate to the likely area of the building at the
NOTE:
1m
2m
FABRICATION DRAWINGS TO BE PROVIDED BY CONTRACTOR FOR APPROVAL PRIOR CONSTRUCTION
REV
DATE
NOTES
INT
1
22.02.16
ISSUED FOR TENDER
IR
PROJECT TITLE
SECTION KEY
STRUTT & PARKER 90 OLD BROMPTON ROAD SW5 9HP DRAWING TITLE
PROPOSED SHOP FRONT PLAN, ELEVATIONS AND SECTIONS
DRAWN
IR
Do not scale from drawing.
CHECKED
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the
KH
SCALE BAR
0
1m
2m
3m
4m
5m
REV
DATE
NOTES
INT
1
22.02.16
ISSUED FOR TENDER
IR
PROJECT TITLE
STRUTT & PARKER 90 OLD BROMPTON ROAD
Strutt & Parker
Old Brompton Road, London Estate agents S&P chose their new location in South Kensington to launch their new eye-catching design with custom finishes across floor, ceiling and walls as well as bespoke joinery, digital displays and metalwork. Project scope: • Liaisong with Client and Design Agency at design stage • Drawing Coordination & Preparation of various technical and detailed drawings. • Pre-Construction Project Management - Programme - Tender process and contract award - Consultant liaison and appointments - Contract negotiation • On-Site Project Management - Site inspection - Cost & Progress reports - Meetings, agendas and minutes - Problem solving and risk mitigation • Post Completion Snagging and Defects - Snagging review - Final account negotiation - O&M infomation compilation - Post completion defects meetings • Cost Reporting and Schedules Project Value: circa £400k
Scarpetta Restaurant Canary Wharf, London
Artisan pasta restaurant in the heart of London’s financial district that evokes timeless Italian design. Situated in one of the busiest squares, it offers a spacious customer area thanks to the new mezzanine. Project scope: • Liaisong with Client and Design Agency at design stage • Drawing Coordination & assistance in the preparation of some technical and detail drawings • Pre-Construction Project Management - Programme - Tender process and contract award - Consultant liaison and appointments - Contract negotiation • On-Site Project Management - Site inspection - Cost & Progress reports - Meetings, agendas and minutes - Problem solving and risk mitigation • Post Completion Snagging and Defects - Snagging review - Final account negotiation - O&M infomation compilation - Post completion defects meetings • Cost Reporting and Schedules Project Value: circa £1 million
Chloe International
Asia, Middle East, Europe, North America Project scope:
Team leader on the development of Chloe´s new concept Store Design Guide. Other work on High-End retail brands include: The Kooples Rag & Bone Breitling Theory Ash Helmut Lang Comptoir de Cotoniers
• Liaisong with Client and In-House Team • Construction drawings • Bespoke joinery drawings • Project Management - (Harrods & Selfridges) - Site Inspection - Tender process and contract award - Meetings, agendas and minutes - Problem solving and risk mitigation - Snagging review - Post completion defects meeting
GLAZING
GLAZING
Elevation (Chengdu - China) HIGH STORES 4000 mm CEILING HEIGHT. 2500 mm HIGH FURNITURE (scale: 1:30)
TOTAL 3D WALL HEIGHT H = 3400 mm
HIGH STORES 4000 mm CEILING HEIGHT. 2500 mm HIGH
TOTAL 3D WALL HEIGHT H = 3400 mm
UNITS HEIGHT H = 2500 mm
UNITS HEIGHT H = 2500 mm
4th SHELF HEIGHT H = 2300 mm
4th SHELF HEIGHT H = 2300 mm
3rd SHELF HEIGHT H = 1750 mm
3rd SHELF HEIGHT H = 1750 mm
2nd SHELF HEIGHT H = 1200 mm
2nd SHELF HEIGHT H = 1200 mm
1st SHELF HEIGHT H = 650 mm
12mm SQUARE SECTION
1st SHELF HEIGHT H = 650 mm
PINK EGEE STONE LOW CUPBOARD
PINK EGEE STONE LOW CUPBOARD
AFFL H= ± 0.00mm
BRUSHED BRASS SKIRTING (H = 30 mm)
CHAMPAGNE MIRROR COLOUR REF: TO MATCH SAMPLE (SEE MATERIAL LIST SPEC)
LO AFFL H= ± 0.00mm
(V3) CH-3D WALL +(V3) DL.4 BACK LIT LOGO
(V3) DF.3 SHELVES ON 3D WALL + (V3) DJ.6 LOW CUPBOARD + (V3) DH.8 LEATHER GOODS DISPLAY BOX
(V3) DF.9 CURVED SHELVES ON 3D WALL + (V3) DK.11 SHOES BRUSHED BRASS PLINTH + (V3) DH.7 3D SHOES DISPLAY SKIRTING (H = 30 mm)
POLISHED BRASS FINISHED LOGO (BACKLIT WITH LED 4000K)
LEATHER GOODS BOX BRUSHED BRASS ILLUMINATED SHELVES WITH TOP COVERED IN LIGHT GREY SPINNEYBECK LEATHER VP 448
Chloe’s “Bible”- Store Design Guide
ANGLE VARIABLE BY WIDTH OF CURVE SPECIAL CORNER DISPLAY 50 x 50 mm HIDDEN STRUCTURE TO SUPPORT THE SHELVES
(V3)ACC DC.12 (V3) DF.8 BOX SHELVES COUNTER MIRROR BLADE ON (V3) DN.23SCHAMPAGNE
14
13
12
NON DISPLAY STORAGE
11
10
9
6
5 4
STOCK ROOM
1
3 2
UP
8
7
GA Plan (Madison Av. - NYC) HIGH STORES 4000 mm CEILING HEIGHT. 2500 mm HIGH FURNITURE (scale: 1:30)
Section (Madison Av. - NYC) HIGH STORES 4000 mm CEILING HEIGHT. 2500 mm HIGH FURNITURE (scale: 1:30)
H FURNITURE (scale: 1:30)
TOTAL 3D WALL HEIGHT H = 3400 mm
TOTAL 3D WALL HEIGHT H = 3400 mm
SQUARE SECTION BAR 25 x 25mm
SQUARE SECTION BAR 25 x 25mm
SQUARE SECTION BAR 25 x 25mm
UNITS HEIGHT H = 2500 mm
UNITS HEIGHT H = 2500 mm
4th SHELF HEIGHT H = 2300 mm
4th SHELF HEIGHT H = 2300 mm
3rd SHELF HEIGHT H = 1750 mm
3rd SHELF HEIGHT H = 1750 mm
SQUARE SECTION BAR 25 x 25mm
OPTION H=1000mm (SHELF AND STORAGE REMAIN AT THE SAME HEIGHT)
2nd SHELF HEIGHT H = 1200 mm
2nd SHELF HEIGHT H = 1200 mm
GLASS BOX DISPLAY
1st SHELF HEIGHT H = 650 mm
1st SHELF HEIGHT H = 650 mm
DRAWER
OCKABLE STORAGE
LOCKABLE STORAGE
DRAWER
AFFL H= ± 0.00mm
AFFL H= ± 0.00mm
(V3) DC.29 2S COUNTER
BRUSHED BRASS SKIRTING (H = 30 mm)
(V3) DH.9 (V3) DC.29 HANGING BUST 2S COUNTER
DA.8 ACC RAIL (V3) (V3) DC.30 1S COUNTER
'L' SHAPE OPTION
SIMPLE RAIL OPTION
(V2) LARGE CJ TABLE
(V3) DA.7 RTW RAIL
'L' SHAPE OPTION
SIMPLE RAIL OPTION
(V2) SMALL CJ TABLE
(V3) DA.9 MIXED RAIL
BRUSHED BRASS SKIRTING (H = 30 mm)
(V3) DG.8 WALL MOUNTED EYEWEAR DISPLAY
DG.7.1/7.2 (V3) DA.13(V3) LOW RAIL PIVOTING EYEWEAR DISPLAY
(V3) DE.7 SINGLE PIVOTING MIRRORS
(V3) DK.2 LOW STOOL(H=450mm) (V3) DK.2 HIGH STOOL (H=600mm)
(V3) DK.4 "L" SHAPE SOFA
(V3) DK.8 SQUARE 2SEATS SOFA
(V3) DK 2SEATS S
Private Residential
South London - Live Project Roof extention that feels like a Tribeca style apartment instead of a loft extension, hugely accessible, with plenty of light, natural finishes and light colours - Clients Brief 45°
45°
LIMIT OF EXTENSION AT SECOND FLOOR
Project scope: • Feasibility studies following client’s brief meeting • Feasibility programme of works • Planning submission drawing pack • Liaison with external consultants and surveyors
AM
PM
No.
5
No. 9
12
**** The above scope carried out to date ****
Location Plan Do not scale from drawing.
info@mailendesign.com
1
11.05.18
NOTES
INT
ISSUED FOR PLANNING
GM
N
The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
PROJECT TITLE
9 VALLEYFIELD ROAD LONDON SW16 2HS
DRAWING TITLE 0
All areas are approximate and measured off preliminary drawings. They relate to the likely area of the building at the current state of the design and using the stated option either in accordance to client standards or the RICS Code of Measuring Practice, 6th Edition, RICS/ISVA. Any decisions to be made on the basis of these predictions, whether as to project viability, pre-letting, lease agreements or the like should include due allowances for the increases and decreases inherent in the design development and building process.
1m
2m
3m
4m
PROPOSED SITE PLAN
5m
DRAWN GM
CHECKED BM
DRAWING NO.
Scale 1:200
Report all drawing errors, omissions and discrepancies to the architect.
17068_1001
SCALE 1:200 @ A3
REVISION 1
2000
700
UNDER ROOF STORAGE SPACE 12m2
www.mailendesign.com
REV DATE
SITE BOUNDARY
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement.
2200
• Construction drawings and Bespoke joinery drawings • Drawing Coordination • Pre-Construction Project Management - Programme - Tender process and contract award - Contract negotiation • On-Site Project Management - Cost & Progress reports - Meetings, agendas and minutes - Problem solving and risk mitigation • Post Completion Snagging and Defects - Snagging review - Final account negotiation - O&M infomation compilation - Post completion defects meetings
No. 11
No. 7
BATHROOM SPACE 7.5m2
900
BEDROOM SPACE 25m2 DRESSING SPACE 7.5m2
PROPOSED SECOND FLOOR PLAN
Proposed GA Plan
REV DATE
Do not scale from drawing.
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement. The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
0
1m
SCALE 1:50
2m
3m
4m
5m
1
11.05.18
NOTES
ISSUED FOR PLANNING
INT TM
PROJECT TI
9 VALLEYFIELD LONDON SW16 2HS
DRAWING T
PROPOSED SEC
65.54 PRECAST STONE FASCIA BAND
FIXED ALUMINUM FRAME PICTURE WINDOW ALUMINUM FRAME WINDOWS
VERTICAL TIMBER CLADDING
BRICKWORK BUILT UP TO MATCH EXISTING
WHITE uPVC WINDOWS RED BRICK - FLEMISH BOND
VELUX ROOFLIGHTS GREY FIBRE CEMENT PANTILES PAINTED FASCIA CREAM
WHITE uPVC WINDOW WHITE uPVC BI-FOLD DOORS RENDER - CREAM BOUNDARY FENCE
PROPOSED REAR ELEVATION
REV DATE
Do not scale from drawing.
Proposed Read Elevation
The author of this drawing takes no responsibility for any dimensions obtained by measuring or scaling from this drawing and no reliance may be placed on such dimensions. If no dimension is given it is the responsibility of the recipient to ascertain the dimension specifically from the author or by site measurement. The sizing of all structural and service elements must always be checked against the relevant engineer's drawings. No reliance should be placed upon sizing information shown on this drawing.
0
1m
SCALE 1:50
2m
3m
4m
5m
1
11.05.18
NOTES
ISSUED FOR PLANNING
INT TM
PROJECT TITLE
9 VALLEYFIELD ROAD LONDON SW16 2HS
DRAWING TITLE
PROPOSED REAR ELEVATION
DRAWN TM
Bank
Project scope:
NOTE: ALL DIMENSIONS MUST BE CHECKED BY CONTRACTOR PRIOR TO MANUFACTURE AND INSTALLATION.
DRAFT
CONTRACTOR TO ALLOW FOR CONFOR THE FOLLOWING REGULATIONS AS NEC
Manchester • Assist with Technical and Detail Design Drawings (Confidential) • Drawing Coordination (MEP, Struc. Engineer, etc.) ALL PROPOSALS SUBJECT TO STRUCTURAL ENGINEERS DETAILS.
30
• On-Site Project Management (Assistance) - Site inspection / Meeting attendance / Problem solving
105
105
LIGHTING DIFFUSERS (IF SPECIFIED) METAL LIG DIFFUSERS WILL BE USED IN THE SUSPENDED C SYSTEM
MECHANICAL CLADDING SYSTEM WITH SECRET FIXINGS. EQUITONE NV3 NVELOPE SYSTEM
CEILING FINISHES TO BE CLASS 0 GENERALLY THROUGHOUT INCLUDING CORRIDOR AND CIRC AREAS
FIXING METHOD TO EXISTING BEAM TO BE CONFIRMED BY MAIN CONTRACTOR
SPRINKLERS TO BE PROVIDED IN ACCORDANCE BRITISH STANDARD 5306 PART 2, HAZARD CLAS HAZARD GROUP IICONTRACTOR TO ALLOW FO
THE FOLLOWING REGULATIO
CONCEALED ROLLER SHUTTER FIXED TO ABOVE STRUCTURE.A5 SPEC TBC BY MAIN CONTRACTOR
700
30
FIRE ALARM TO BS5839 PART 1 : 1988. A TYPE 'M GLASS FIRE ALARM SYSTEM WILL BE PROVIDED WALL FINISHES TO WITH BE CLASS 1 GE AND INSTALLED IN ACCORDANCE BRITISH FINISHES TO CORRIDORS AND CIR 5839 PART 1
CAVITY BARRIERS TO BE PROVIDE
A SMOKE DETECTION SYSTEM WILL BE PROVID MAXIMUM 20M CENTRES. EXCEPT DESIGNED AND INSTALLED IN ACCORDANCE WI IS OVER A SINGLE ENCLOSED ROO STANDARD 5839 PART 1. AT A MAXIMUM 40 M CE PROVIDED
FIRE EXTINGUISHERS INSTALLED TO BS5036 PA
LIGHTING DIFFUSERS (IF SPECIFIE CONCEALED AIR CURTAIN FIXED EXISTING COLUMN. FINAL SIZE TBC WATER TYPE FIRE EXTINGUISHERS WILL IN BETHE PR DIFFUSERS WILL BE USED BY STRUCTURAL TO ABOVE STRUCTURE. SPEC TBC ENGINEER. SYSTEM THE RATE OF ONE FOR EVERY 200M SQ OF FLO BY M&E CONTRACTOR
A5
SPECIALIST WILL BE PROVIDED MECHANICAL CLADDING SYSTEM WITHEXTINGUISHER CEILING FINISHES TO BE CLASS 0 THENV3 INDIVIDUAL RISKS WHEN IDENTIFIED SECRET FIXINGS. EQUITONE THROUGHOUT INCLUDING CORRID NVELOPE SYSTEM AREAS
520
520
700
CAVITY BARRIERS TO BE PROVIDED IN CEILING MAXIMUM 20M CENTRES. EXCEPT WHEN THE CE IS OVER A SINGLE ENCLOSED ROOM WHERE TH PROVIDED AT A MAXIMUM 40 M CENTRES
A5
700
EXISTING COLUMN. FINAL SIZE TBC BY STRUCTURAL ENGINEER.
DRAFT
NOTE: ALL DIMENSIONS MUST BE CHECKED BY CONTRACTOR PRIOR TO MANUFACTURE AND INSTALLATION. ALL PROPOSALS SUBJECT TO STRUCTURAL ENGINEERS DETAILS.
WALL FINISHES TO BE CLASS 1 GENERALLY WIT FINISHES TO CORRIDORS AND CIRCULATION AR
NOTICES TO BS5499 PART 1 '1990 SUFFICIENT F
FIXING METHOD TO EXISTING NOTICES WILL BESPRINKLERS PROVIDED TO TOBE ENABLE THEINO PROVIDED
BEAM TO BE CONFIRMED BY STANDARD OF THE BUILDINGBRITISH TO IDENTIFY ALL 5306 THE PART FIRE 2, EXH LINEAR SLOT DIFFUSER MAIN CONTRACTOR
135
135 54
210 54
3
4 202 30
105
105
GLASS FINS. TOUGHENED AND HEAT SOAK GLASS
520
135
3100
3100
700
700
CROSS REFERENCE WITH OTHE
REV
DATEALL DIMENSIONS. DESCRIPTION
REV NEW FASCIA CLADDING TO OVERLAP WINDOW FRAME
Scale: 1:10
DO NOT SCALE FROM THIS DRAW DATE DESCRIPTION ANY CHANGES ON SPECIFICATIO 'I-AM' ASSOCIATES.
ALL WORKS TO COMPLY WITH L SITE REGULATIONS.
ROOT ANGLE FOR SINGLE TOUGHENED GLASS FIN
COPYRIGHT 'I-AM' ASSOCIATES
A5
A19 375
700 A5 B WORK SIGN REFER TO SIGNAGE PACK FOR DETAILS
A5
4
335
225
A19 700
3570
3570
POWDER COATED ALUMINIUM. REFER TO FINISHES SCHEDULE FOR DETAILS
DATE
DESCRIPT
REV
DATE
DESCRIPTIO
Scale: 1:10
3 202
ROLLER SHUTTER GUIDE RAIL
REV
DETAIL 2
NEW FASCIA CLADDING TO OVERLAP WINDOW FRAME EXTERNALLY
CL
A5
ASSESSMENT OF SUITABLE WEATHER PROOFING TO BE CARRIED OUT BY CONTRACTOR FOLLOWING EXISTING FACADE REMOVAL
700
ROLLER SHUTTER GUIDE RAIL
745 750
833
3570
3622
POWDER COATED ALUMINIUM. REFER TO FINISHES SCHEDULE FOR DETAILS
FOR ATM CUTOUT SIZE REFER TO SPECIALIST SUPPLIERS DRAWINGS
POWDER COATED ALUMINIUM. REFER TO FINISHES SCHEDULE FOR DETAILS
CL
3570
700
3622
DETAIL 2
620
A5 700
4
CL
ASSESSMENT OF SUITABLE WEATHER PROOFING TO BE CARRIED OUT BY EXISTING COLUMN. FINAL SIZE TBC CONTRACTOR FOLLOWING EXISTING BY STRUCTURAL ENGINEER. FACADE REMOVAL
A19
Scale: 1:20
66 Leonard Street London EC2A 4LW
Tel: 0207 613 4114 DWG STATUS Design
Email: hello@i-amo
David Judic
A19
Proposed Shopfro
48-50 M
1:25 @ A1 / 1:50
GLASS FINS. TOUGHENED AND HEAT SOAK GLASS
DETAIL 3
Emai
B Works
700
5
66 Le Lond EC2A
Tel: 0
B Works
David Ju 48-50 Market Stre
GLASS FINS. TOUGHENED AND HEAT SOAK GLASS
815 810 275
SECTION B-B
EXISTING COLUMN. FINAL SIZE TBC BY STRUCTURAL ENGINEER.
700
135
275
2
700
Design Intent
MECHANICAL CLADDING SYSTEM WITH SECRET FIXINGS. EQUITONE NV3 NVELOPE SYSTEM
FOR ATM CUTOUT SIZE REFER TO SPECIALIST SUPPLIERS DRAWINGS
135
815 810
833
POWDER COATED ALUMINIUM. REFER TO FINISHES SCHEDULE FOR DETAILS
A5
DWG STATUS
MECHANICAL CLADDING WITH NEW SYSTEM FASCIA CLADDING TO OVERLAPNV3 WINDOW FRAME SECRET FIXINGS. EQUITONE NVELOPE SYSTEM EXTERNALLY
745 750
375
595
620
A5 700
EXISTING WALLS/PARTITIONS
ALL DIMENSIONS.
700
202
3
JOINTS TO RECEIVE DECORATION PROVIDING MINIMUM 1/2 HOUR FIR
I-AM ASSOCIATES RECOMMEND FULL MEASU RESISTANCE AND MINIMUM CLASS BY CONTRACTOR PRIOR FINALISATION O SPREAD OFTO FLAME DRAWINGS AND MANUFACTURING.
EXISTING FASCIA CLADDING CROSS REFERENCE WITH OTHER DRAWINGS
A5
5
945
NEW STUD PARTITIONING CONSISTING OF 70MM STUDS AT MAXIMUM 600MM CENTRES FACIN
WITH ONE LAYER OF 12.5MM DESIGN INTENT SIDES DRAWING ONLY - BASED ON PLASTERBOARD SCRIMMED AND T SUPPLIED.
DO NOT SCALE FROM THIS DRAWING .
A19
B WORK SIGN REFER TO SIGNAGE PACK FOR DETAILS
NOTES
NOTES ASSESSMENT OF SUITABLE WEATHER PROOFING AND INSULATION TOCHANGES BE ANY ON SPECIFICATION TO BE AG NEW FASCIA CLADDING TO CARRIED OUT BY CONTRACTOR OVERLAP WINDOW FRAME 'I-AM' ASSOCIATES. FOLLOWING EXISTING FACADE REMOVAL DESIGN INTENT DRAWING ONLY SUPPLIED. EXISTING FASCIA CLADDING TO ALL WORKS TO COMPLY WITH LOCAL AUTHO BE REMOVED PRIOR TO THE ROOT ANGLE FOR SINGLE SITE REGULATIONS. I-AM ASSOCIATES RECOMMEND OF THE NEW TOUGHENED GLASS INSTALLATION FIN BY CONTRACTOR PRIOR TO FIN CLADDING SYSTEM. DRAWINGS AND MANUFACTURIN COPYRIGHT 'I-AM' ASSOCIATES 2016
CL
620
595
A5 700
EXISTING FASCIA CLADDING TO BE REMOVED PRIOR TO THE INSTALLATION OF THE NEW CLADDING SYSTEM.
700
700
Scale: 1:20
ASSESSMENT OF SUITABLE WEATHER PROOFING AND INSULATION TO BE CARRIED OUT BY CONTRACTOR FOLLOWING EXISTING FACADE REMOVAL
3100
3100
620
A5 700
202
SECTION A-A
EXISTING WALLS/PARTITIONS ACCORDANCE WITH BRITISH STAN
STUD PARTITIONING
A5
A5
1
3 HOUR NON - MAINTAINED EMERG WILL BE PROVIDED DESIGNED AN
EXISTING FASCIA CLADDING
A5
5
A5
Scale: 1:10
REFER TO DRAWING J736_405 FOR FIRST FLOOR GLAZED PARTITION DETAILS
202
700
DETAIL 1
LOW E LAMINATED SINGLE GLASS WITH PVB INTERLAYER AND FULLY TRANSPARENT BOMB FILM APPLIED INTERNALLY
945
335
3
THE RATE OF ONE FOR EVERY 200 SPECIALIST EXTINGUISHER WILL B
GLASS FINS. TOUGHENED AND HEAT SOAK GLASS
700
225
210 54
4 202
A19
700 A5
FIRE EXTINGUISHERS INSTALLED
NEW STUD PARTITIONING THE INDIVIDUAL RISKS WHEN IDEN CONSISTING OF 70MM STUDS AT NOTICES TO BS5499 PART 1 '1990 MAXIMUM 600MM CENTRES FACING BOTH NOTICES WILL BE PROVIDED TO E SIDES WITH ONE OF LAYER OF 12.5MM THE BUILDING TO IDENTIFY AL LINEAR SLOT DIFFUSER PLASTERBOARD NOT SCRIMMED AND TAPED IN EVERYDAY USE. JOINTS TO RECEIVE ALL DECORATION FIRE RESISTING DOORS WILL PROVIDING MINIMUM 1/2AHOUR FIRE KEEP SHUT EITHER FIRE DOOR LOCKED SHUT1WHEN NOT IN RESISTANCE ANDKEEP MINIMUM CLASS SPREAD OF FLAME
REFER TO DRAWING J736_405 FOR FIRST FLOOR GLAZED PARTITION DETAILS
54
700
690
STANDARD 5839 PART 1.
30
STUD PARTITIONING WATER TYPE FIRE LEGEND EXTINGUISHER
135
A5
690
3 HOUR NON - MAINTAINED EMERGENCY LIGHTI CONCEALED ROLLER SHUTTER FIXED A SMOKE DETECTION SYSTEM WIL WILLTBC BE PROVIDED DESIGNED AND INSTALLED TO ABOVE STRUCTURE. SPEC DESIGNED AND INSTALLED IN ACC BY MAIN CONTRACTOR ACCORDANCE WITH BRITISH STANDARD5266 PA CONCEALED AIR CURTAIN FIXED TO ABOVE STRUCTURE. SPEC TBC BY M&E CONTRACTOR
700
520
LOW E LAMINATED SINGLE GLASS WITH PVB INTERLAYER AND FULLY TRANSPARENT BOMB FILM APPLIED INTERNALLY
HAZARD NOT IN EVERYDAY USE. GROUP II ALL FIRE RESISTING DOORS WILL BE PROVIDED FIRE ALARM TO BS5839 PART 1 : 1 EITHER A FIRE DOOR KEEP A GLASS FIRESHUT ALARMNOTICE SYSTEMOR WILL KEEP LOCKED SHUT NOTIN INACCORDANCE USE ANDWHEN INSTALLED 5839 PART 1
Scale: 1:10
A5
REFER TO DRAWING J736_405 FOR FIRST FLOOR GLAZED PARTITION DETAILS
REFER TO DRAWING J736_405 FOR FIRST FLOOR GLAZED PARTITION DETAILS
DETAIL 1
27.07.18 Propose
Scale: 1:10
IR 5
DETAIL 3 Scale: 1:10
DWG NO.
1:25 @ A
J736_202 27.07.18 IR
DRAFT
INSTALLATION. ALL PROPOSALS SUBJECT TO STRUCTURAL ENGINEERS DETAILS. A22
A18
700
700
C-C 404
F8
A22
A19
700
700
700
6795
CLEAR LOW IRON TOUGHENED GLASS BALUSTRADE
05 405
LIGHTING DIFFUSERS DIFFUSERS WILL BE U SYSTEM
1100
FIRE ALARM TO BS58 GLASS FIRE ALARM S AND INSTALLED IN AC 5839 PART 1
FIRE EXTINGUISHERS WATER TYPE FIRE EX THE RATE OF ONE FO SPECIALIST EXTINGU THE INDIVIDUAL RISK
A-A 404
20
19
18
17
16
15
14
13
12
11
9
8
7
6
5
4
3
2
1
10
DOUBLE POWER SOCKET & USB CHARGER
NOTICES TO BS5499 P NOTICES WILL BE PRO OF THE BUILDING TO NOT IN EVERYDAY US ALL FIRE RESISTING D EITHER A FIRE DOOR KEEP LOCKED SHUT W
A22
3615
700 3615
SPRINKLERS TO BE P BRITISH STANDARD 5 HAZARD GROUP II
A SMOKE DETECTION DESIGNED AND INSTA STANDARD 5839 PART
VISIBILITY STRIP 1200
CAVITY BARRIERS TO MAXIMUM 20M CENTR IS OVER A SINGLE EN PROVIDED AT A MAXI
CEILING FINISHES TO THROUGHOUT INCLU AREAS
6910
3700
WALL FINISHES TO BE FINISHES TO CORRID
3 HOUR NON - MAINTA WILL BE PROVIDED D ACCORDANCE WITH B
B-B
STUD PARTIT
04
2360
2224
404
405
NEW STUD PARTITION CONSISTING OF 70MM MAXIMUM 600MM CEN SIDES WITH ONE LAY PLASTERBOARD SCR JOINTS TO RECEIVE D PROVIDING MINIMUM RESISTANCE AND MIN SPREAD OF FLAME
DOUBLE POWER SOCKET & USB CHARGER DOUBLE SIDED PARTITION TYPE 2
EXISTING WALLS/PAR
6795 6910
NOTES
DESIGN INTENT DRA SUPPLIED.
1
PROPOSED STAIR: Plan View
4
Scale: 1:25
I-AM ASSOCIATES R BY CONTRACTOR PR DRAWINGS AND MAN
SECTION C-C Scale: 1:25
CROSS REFERENCE ALL DIMENSIONS.
DO NOT SCALE FRO
ANY CHANGES ON S 'I-AM' ASSOCIATES.
CLEAR LOW IRON TOUGHENED GLASS BALUSTRADE
EQ.
EQ.
EQ.
EQ.
EQ.
EQ.
ALL WORKS TO COM SITE REGULATIONS.
A19
CLEAR LOW IRON TOUGHENED GLASS BALUSTRADE
VISIBILITY STRIP
700
COPYRIGHT 'I-AM' AS
EQ.
EQ.
REV
DATE
REV
DATE
1100
700
1100
A19
07 405
1100
06 405
230
900
SILICON JOINT
A19
A18
700
SILICON JOINT
700
900
700
1100
A18
900
03 405
DWG STATUS
1200
02
DOUBLE SIDED PARTITION TYPE 1
405
01 A18
405 1100
700
600
360
180
900
300
TIMBER UPSTAND (A22)
TIMBER UPSTAND (A22)
STEEL HANDRAIL (A18)
2
SECTION A-A Scale: 1:25
STAIR SUPPORT STRUCTURE TO BE CALCULATED BY SPECIALIST
3
SECTION B-B Scale: 1:25
DWG NO.
thank you
igor ruiz apilanez