9 minute read
Individual Temperature Control Cuts Utility Costs
by IdeaSoil
Independent room controls prevent energy waste from overheating or overcooling.
In recent years, average rent for a one-bedroom apartment in Brooklyn’s Bushwick neighborhood has skyrocketed to more than $3,000 a month, excluding utilities. That’s why New York City’s Department of Housing Preservation and Development (HPD) and Ridgewood Bushwick Senior Citizens Council (RBSCC) came together to develop Knickerbocker Commons.
Advertisement
RBSCC also wanted to radically cut tenant utility costs without compromising comfort. So, they enlisted Chris Benedict, R.A., New
York, to design an ultra-low-energy building. Henry Gifford, who works for Chris Benedict, designed the mechanical systems for the building. The team combined several technologies, such as continuous exterior insulation, energy-recovery ventilators, sealed-combustion boilers, and individual room-thermostat controls, including Baltimore-based Danfoss’, thermostatic radiator valves (TRVs). According to Gifford, the result is 90% lower energy consumption than comparable buildings—and heating costs below $50/apartment/year.
“The 803 Knickerbocker Avenue building was completed in 2014,” said Gifford. “We used proven building-science concepts that could be applied to any high-performance building. No energy-efficiency rebates defrayed the cost of the low-energy technology we used. In fact, we delivered an extreme level of efficiency and comfort without adding to the construction cost.”
Known for his life-long passion for building science, Henry Gifford attended the first class in the U.S. on ultra-low-energy building principles known as “Passive House.” According to Gifford, who recently published the book, Buildings Don’t Lie: Better Buildings by
Understanding Basic Building Science, “If you understand the underlying science, you’ll have the tools to improve buildings from the start.”
The Passive House principles use a continuous air barrier and exterior insulation. These construction techniques eliminate thermal bridging, creating an interior space that can maintain a comfortable temperature. Natural light and human activities keep the space generally warm. Mechanical systems handle domestic hot-water production and extreme hot and cold conditions.
When energy prices in Europe more than quintupled in the early 2000s, the “Passivhaus” idea took off—with more than 25,000 buildings on the continent meeting the voluntary, ultra-low-energy building standard by 2010.
In the United States, energy-cost hikes were not that extreme, but rising. In 2011, Gifford and Benedict were presented with two projects ideal for the unique design approach, one of which was Knickerbocker Commons.
Proven building-science concepts were used in the Knickerbocker Commons building to deliver an extreme level of efficiency and comfort without adding to the construction cost.
“It’s not merely about meeting a standard, but simply implementing the smartest possible building-science principles,” said Gifford. “That means integrating all building systems (insulation, water, lighting, and heating, cooling, and ventilating) into a cost-effective, holistic solution. That’s why a device like the Danfoss thermostatic radiator valve plays a big role in creating a comfortable, energy-efficient building.”
A THERMOSTAT FOR EACH ROOM One of Gifford’s design principles is that each room should have its own thermostat.
Gifford explained, “If a simple building with only two rooms is located where the sun shines from one direction and the wind blows from another direction, the heating and cooling loads will vary between rooms. Putting a single thermostat in one room will keep that room warm, but leave the other too hot or cold. Plus, internal loads will vary depending on cooking, showering, computers, and lighting. The temperature imbalance becomes very noticeable if the building is well insulated. People will run space heaters in winter to heat the cold room, and/or open windows in a hot room. That’s a huge waste of energy, and it makes the air dry and unhealthy.”
To avoid balance problems, Gifford specified each room at 803 Knickerbocker with a radiator controlled by its own individual thermostat.
Gifford observed that, “individual-room temperature control makes the whole apartment comfortable without wasting energy by overheating or overcooling. This allows the system to be downsized, which saves enough money to more than pay for the additional thermostats.”
To regulate the flow of hot water through the radiators, Danfoss RA2000 TRVs with a tamper-resistant non-electric operator were used. The RA2000 TRV is designed for hot water or low-pressure steam. In this case, the valves were installed on wall-mounted baseboard radiators to avoid coordination difficulties between flooring installers and plumbers.
The TRV regulates hot-water flow by using an integrated thermostat and valve assembly. A white knob containing a sealed capsule filled with a heat-sensitive vapor charge functions as the thermostat. If the room is too warm, the rise of temperature increases the vapor pressure in the bellows, closing the valve. If cold, the pressure decreases, opening the valve. In typical operation, the valve is not either fully opened or closed. Rather, it modulates between open, closed, or partly open based on a proportional difference between actual and desired temperatures.
With the TRV, controlling space temperature is easy. The apartment resident turns the knob to the desired temperature. The dial is scaled in five increments about 5-deg. F apart, ranging from 57 F to 79 F. Gifford set the upper temperature limit to 73 F, but residents can lower the temperature setting, if desired.
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/a328211fe73f66c9e4dfc673573fab7a.jpg?width=720&quality=85%2C50)
To avoid balance problems, each room was provided with a radiator controlled by its own Danfoss RA2000 thermostatic radiator valve (TRV).
“Psychological studies show that when people have control over room temperature, they tend to be more satisfied with their environment,” he noted. “That’s particularly valuable in mild weather when controlling temperature is difficult and a lot of energy is wasted due to overheating.”
REWARDING ENERGY SAVINGS Using room thermostat control in the integrated building design has produced extraordinary energy savings. Despite its 34,581 sq. ft., the property’s peak heating load is only 127,000 Btu/hr.
“This is an incredibly low heat load for a building of this size,” said Gifford. “But, just because the load for space heating goes down doesn’t mean the domestic hot water load is reduced. We put two small, sealed-combustion gas boilers in a mechanical room on the roof. The boiler capacity is primarily used to make domestic hot water and, secondarily, heat the building, which is opposite from the responsibility of most boilers in other buildings. We have four storage tanks for the domestic hot water, and we use the smallest, most efficient pumps possible to circulate water in the hydronic loop.”
A 1/8-hp pump supplies a two-pipe hot-water system, which runs whenever the outdoor temperature is lower than 55 F, serving the entire building. The Danfoss valves on each radiator control flow through the radiator.
The bottom line for the Passive House design: The space heating cost for each apartment averages about $44/yr. in a building constructed for the same cost/sq. ft. as any other NYC affordable-housing facility.
The ultra-low energy performance, comfort, and aesthetics of 803 Knickerbocker have been widely recognized. It was the first midsized apartment building in the United States to be certified to the Passive House standard, and was recognized in New York City Mayor Bill de Blasio’s One City Built To Last program as an innovative approach to reducing the city’s carbon footprint.
The building is further proof that an integrated, holistic approach to design is practical. It also has helped spur changes in NYC building code and zoning regulations to enable construction of more ultra-low-energy buildings.
However, most important to Gifford is the legacy of comfortable tenants and property owners. Gifford noted, “Since 803 Knickerbocker opened in 2014, there have been zero tenant complaints about heating. When you can make both tenants and property owners happy in Brooklyn, it shows using thermostatic radiator valves for every room really works.” CA
Want more information from Danfoss (danfoss.com)? Circle 3 on the Reader Service Card.
Sources listed below are linked at commercialarchitecturemagazine.com/1904danfoss.
• New York City’s Department of Housing Preservation and Development, nyc.gov/hpd
Ridgewood Bushwick Senior Citizens Council, riseboro.org • Chris Benedict, R.A.,
linkedin.com/in/chris-benedict-2abb8bb/
One City Built to Last, www1.nyc.gov/site/builttolast
EDITORS’ CHOICE
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/e768a5ecc260813ecf5d16a7b6f7c129.jpg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/9c5e15a22422855c0512bbcf3661d5df.jpg?width=720&quality=85%2C50)
VRF systems for light, mid-size applications
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/44a35e647e15e8feb93c3a27c9b26112.jpg?width=720&quality=85%2C50)
Airstage J-IIIL heat pumps:
Light to mid-sized applications Compact, slim design Wide range of indoor units
Airstage J-IIIL heat pumps in the VRF system line, for light to mid-sized applications, have a compact, slim design suited for limited installation space. Front-facing fans and a compact chassis permit the outdoor unit to be installed in narrow spaces, whether ground- or wall-mounted. Quiet operation ensures that building occupants are not disturbed. Six, eight, and ten-ton heat-pump systems are available. As many as 30 indoor units can be connected to the 10-ton outdoor condensing unit. irteen di erent types of indoor units are compatible, with capacities from 4,000 to 96,000 Btuh. Advanced refrigerant technology allows systems to reach a total refrigerant piping length of 1,312 ft., while the height di erence between indoor and outdoor units can be as much as 164 ft. External static pressure is available to 0.24in. W.G (60Pa).
Fujitsu General America, Fairfi eld, NJ Circle 71 fujitsugeneral.com
Lifting station for multiple fi xtures The Sanicubic 2 lifting station consists of two, 1-hp motors housed inside a compact but highly durable plastic enclosure. Each operating grinder has its own high-performance grinding system: a fast-rotating blade to reduce solids in the drainage stream from toilets, tubs and showers, sinks, washing machines, and dishwashers. The two grinders operate alternately, taking turns handling the incoming waste so that neither is more heavily used over time than the other.
Sanifl o USA, Edison, NJ Circle 74 sanifl o.com
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/bb2e1ff4739cf1adcc0be746da619bb7.jpg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/06fba668df428612a73c825479bcbafa.jpg?width=720&quality=85%2C50)
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/bf07cfd8948c7a475e53e31074e7e89e.jpg?width=720&quality=85%2C50)
Expanded line of gas boilers A full line of high-effi ciency gas boilers includes the Evergreen, Ultra Series 4, GV90+ cast-iron, and the AquaBalance Series 2. All units operate with natural or propane gas and have the latest hydronic heating technology to provide heating comfort and energy savings. Evergreen line is available in six sizes from 70 to 399 MBH input. Ultra Series 4 boilers have a nanotechnology coating that works like Ultra Armor, protecting units from buildup in the heat exchanger. The GV90+ has an AFUE rating of 91%. AquaBalance Series 2 units have an energy effi ciency of 95%.
Weil-McLain, Burr Ridge, IL Circle 72 weil-mclain.com
![](https://assets.isu.pub/document-structure/200924185522-cc2e8b27bc40a44daab2a4cf491afd73/v1/dcda1698af7476c3687e1e28dac458e4.jpg?width=720&quality=85%2C50)
Roof-venting system Using the existing roof as an air barrier, the company uses a vented-roof design said to virtually eliminate fl utter. With no peel, no shear, and no fl utter, no pressure is transferred to the roof seams. The vented system is patented, designed, and tested to meet high-wind requirements.