International Journal of Advanced Engineering Research and Science (IJAERS) Peer-Reviewed Journal ISSN: 2349-6495(P) | 2456-1908(O) Vol-8, Issue-8; Aug, 2021 Journal Home Page Available: https://ijaers.com/ Article DOI: https://dx.doi.org/10.22161/ijaers.88.1
Solid Index versus Impression for transferring the Position of implants in Mandibular total Edentulous Arches: A Clinical study on trueness Ana Larisse Carneiro Pereira1, Henrique Vieira Melo Segundo2, Maria de Fátima Trindade Pinto Campos3, Míria Rafaelli Souza Curinga4, Ana Clara Soares Paiva Tôrres5, Adriana da Fonte Porto Carreiro6,* 1DDS,
MSc, PhD student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil. student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil. 3Collaborating Professora, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil. 4DDS, MSc student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil. 5Professora, Department of Dentistry, State University of Rio Grande do Norte (UERN), Caicó, RN, Brazil. 6Professora Titular, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil. *Corresponding author 2Graduation
Received:28 Jun 2021; Received in revised form: 14 Jul 2021; Accepted: 25 Jul 2021; Available online: 06 Aug 2021 ©2021 The Author(s). Published by AI Publication. This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/). Keywords— splinting, direct edentulous, dental abutments.
I.
technique,
Abstract— To evaluate the trueness of two techniques for transferring the position of implants, with respect to the angles and distances between them, in completely edentulous arches rehabilitated with 3 and 4 implants. All patients were subjected to 2 impressions techniques: solid index (SI) and conventional impression using the open tray (MC) technique. The cast models were digitized by a laboratory scanner, and the generated STL files were imported into engineering software to measure the axes of the coordinates of the implants and the distances between the implants. The Wilcoxon test was used to identify the differences between the SI and MC groups (p<0.05). The Spearman correlation coefficient was applied to identify the correlation between the coordinate axes and the distances between the implants (p<0.05). When comparing the SI and MC groups, a significant difference was observed in the x-axis of implant #1, for the arches with 3 and 4 implants (p<0.05). As for the distances, a significant difference was observed between implants 1-2 in the arches with 4 implants (p<0.05). No correlation was identified between the two dependent variables. The SI, as well as the MC, must be developed to obtain a passive adjustment framework.
INTRODUCTION
The passive adjustment of implant-supported fixed total prostheses is a determining factor for their long-term success.1-4 Biological and mechanical complications, such as progressive marginal bone loss (peri-implantitis), increase or accumulation of biofilm (mucositis), loosening of the abutment screw, fatigue fractures in the prosthetic components5,6 or the implant, and loss of osseointegration,
www.ijaers.com
,may contribute to the inadequate adjustment of the metallic infrastructure with the abutments or implant, to varying extents.2,4 The impression techniques and materials,4,7 impression copings, presence or absence of splinting, as well as the splint material and the number and angulations of the implants4,8 are factors that affect the transfer precision of the position of the implants to the mold and later to the
Page | 1