Aug 2020 International Journal of Innovative Technology and Creative Engineering (ISSN:2045-8711)

Page 1

INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

UK: Managing Editor International Journal of Innovative Technology and Creative Engineering 1a park lane, Cranford London TW59WA UK

USA: Editor International Journal of Innovative Technology and Creative Engineering Dr. Arumugam Department of Chemistry University of Georgia GA-30602, USA.

India: Editor International Journal of Innovative Technology & Creative Engineering 36/4 12th Avenue, 1st cross St, Vaigai Colony Ashok Nagar Chennai , India 600083 Email: editor@ijitce.co.uk

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

IJITCE PUBLICATION

International Journal of Innovative Technology & Creative Engineering Vol.10 No.8 August 2020

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

Dear Researcher, Greetings! Articles in this issue discusses about Magnetic Resonance Imaging of the Brain. It has been an absolute pleasure to present you articles that you wish to read. We look forward many more new technologies in the next month.

Thanks, Editorial Team IJITCE


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

Editorial Members Dr. Chee Kyun Ng Ph.D Department of Computer and Communication Systems, Faculty of Engineering,Universiti Putra Malaysia,UPMSerdang, 43400 Selangor,Malaysia. Dr. Simon SEE Ph.D Chief Technologist and Technical Director at Oracle Corporation, Associate Professor (Adjunct) at Nanyang Technological University Professor (Adjunct) at ShangaiJiaotong University, 27 West Coast Rise #08-12,Singapore 127470 Dr. sc.agr. Horst Juergen SCHWARTZ Ph.D, Humboldt-University of Berlin,Faculty of Agriculture and Horticulture,Asternplatz 2a, D-12203 Berlin,Germany Dr. Marco L. BianchiniPh.D Italian National Research Council; IBAF-CNR,Via Salaria km 29.300, 00015 MonterotondoScalo (RM),Italy Dr. NijadKabbara Ph.D Marine Research Centre / Remote Sensing Centre/ National Council for Scientific Research, P. O. Box: 189 Jounieh,Lebanon Dr. Aaron Solomon Ph.D Department of Computer Science, National Chi Nan University,No. 303, University Road,Puli Town, Nantou County 54561,Taiwan Dr. Arthanariee. A. M M.Sc.,M.Phil.,M.S.,Ph.D Director - Bharathidasan School of Computer Applications, Ellispettai, Erode, Tamil Nadu,India Dr. Takaharu KAMEOKA, Ph.D Professor, Laboratory of Food, Environmental & Cultural Informatics Division of Sustainable Resource Sciences, Graduate School of Bioresources,Mie University, 1577 Kurimamachiya-cho, Tsu, Mie, 514-8507, Japan Dr. M. Sivakumar M.C.A.,ITIL.,PRINCE2.,ISTQB.,OCP.,ICP. Ph.D. Project Manager - Software,Applied Materials,1a park lane,cranford,UK Dr. Bulent AcmaPh.D Anadolu University, Department of Economics,Unit of Southeastern Anatolia Project(GAP),26470 Eskisehir,TURKEY Dr. Selvanathan Arumugam Ph.D Research Scientist, Department of Chemistry, University of Georgia, GA-30602,USA. Dr. S.Prasath Ph.D Assistant Professor, Department of Computer Science, Nandha Arts & Science College, Erode , Tamil Nadu, India


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

Review Board Members Mr. Rajaram Venkataraman Chief Executive Officer, Vel Tech TBI || Convener, FICCI TN State Technology Panel || Founder, Navya Insights || President, SPIN Chennai Dr. Paul Koltun Senior Research ScientistLCA and Industrial Ecology Group,Metallic& Ceramic Materials,CSIRO Process Science & Engineering Private Bag 33, Clayton South MDC 3169,Gate 5 Normanby Rd., Clayton Vic. 3168, Australia Dr. Zhiming Yang MD., Ph. D. Department of Radiation Oncology and Molecular Radiation Science,1550 Orleans Street Rm 441, Baltimore MD, 21231,USA Dr. Jifeng Wang Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign Urbana, Illinois, 61801, USA Dr. Giuseppe Baldacchini ENEA - Frascati Research Center, Via Enrico Fermi 45 - P.O. Box 65,00044 Frascati, Roma, ITALY. Dr. MutamedTurkiNayefKhatib Assistant Professor of Telecommunication Engineering,Head of Telecommunication Engineering Department,Palestine Technical University (Kadoorie), TulKarm, PALESTINE. Dr.P.UmaMaheswari Prof &Head,Depaartment of CSE/IT, INFO Institute of Engineering,Coimbatore. Dr. T. Christopher, Ph.D., Assistant Professor &Head,Department of Computer Science,Government Arts College(Autonomous),Udumalpet, India. Dr. T. DEVI Ph.D. Engg. (Warwick, UK), Head,Department of Computer Applications,Bharathiar University,Coimbatore-641 046, India. Dr. Renato J. orsato Professor at FGV-EAESP,Getulio Vargas Foundation,São Paulo Business School,RuaItapeva, 474 (8° andar),01332-000, São Paulo (SP), Brazil Visiting Scholar at INSEAD,INSEAD Social Innovation Centre,Boulevard de Constance,77305 Fontainebleau - France Y. BenalYurtlu Assist. Prof. OndokuzMayis University Dr.Sumeer Gul Assistant Professor,Department of Library and Information Science,University of Kashmir,India Dr. ChutimaBoonthum-Denecke, Ph.D Department of Computer Science,Science& Technology Bldg., Rm 120,Hampton University,Hampton, VA 23688 Dr. Renato J. Orsato Professor at FGV-EAESP,Getulio Vargas Foundation,São Paulo Business SchoolRuaItapeva, 474 (8° andar),01332-000, São Paulo (SP), Brazil Dr. Lucy M. Brown, Ph.D. Texas State University,601 University Drive,School of Journalism and Mass Communication,OM330B,San Marcos, TX 78666 JavadRobati Crop Production Departement,University of Maragheh,Golshahr,Maragheh,Iran VineshSukumar (PhD, MBA) Product Engineering Segment Manager, Imaging Products, Aptina Imaging Inc. Dr. Binod Kumar PhD(CS), M.Phil.(CS), MIAENG,MIEEE HOD & Associate Professor, IT Dept, Medi-Caps Inst. of Science & Tech.(MIST),Indore, India Dr. S. B. Warkad Associate Professor, Department of Electrical Engineering, Priyadarshini College of Engineering, Nagpur, India Dr. doc. Ing. RostislavChoteborský, Ph.D. Katedramateriálu a strojírenskétechnologieTechnickáfakulta,Ceskázemedelskáuniverzita v Praze,Kamýcká 129, Praha 6, 165 21 Dr. Paul Koltun Senior Research ScientistLCA and Industrial Ecology Group,Metallic& Ceramic Materials,CSIRO Process Science & Engineering Private Bag 33, Clayton South MDC 3169,Gate 5 Normanby Rd., Clayton Vic. 3168


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 DR.ChutimaBoonthum-Denecke, Ph.D Department of Computer Science,Science& Technology Bldg.,HamptonUniversity,Hampton, VA 23688 Mr. Abhishek Taneja B.sc(Electronics),M.B.E,M.C.A.,M.Phil., Assistant Professor in the Department of Computer Science & Applications, at Dronacharya Institute of Management and Technology, Kurukshetra. (India). Dr. Ing. RostislavChotěborský,ph.d, Katedramateriálu a strojírenskétechnologie, Technickáfakulta,Českázemědělskáuniverzita v Praze,Kamýcká 129, Praha 6, 165 21

Dr. AmalaVijayaSelvi Rajan, B.sc,Ph.d, Faculty – Information Technology Dubai Women’s College – Higher Colleges of Technology,P.O. Box – 16062, Dubai, UAE

Naik Nitin AshokraoB.sc,M.Sc Lecturer in YeshwantMahavidyalayaNanded University Dr.A.Kathirvell, B.E, M.E, Ph.D,MISTE, MIACSIT, MENGG Professor - Department of Computer Science and Engineering,Tagore Engineering College, Chennai Dr. H. S. Fadewar B.sc,M.sc,M.Phil.,ph.d,PGDBM,B.Ed. Associate Professor - Sinhgad Institute of Management & Computer Application, Mumbai-BangloreWesternly Express Way Narhe, Pune - 41 Dr. David Batten Leader, Algal Pre-Feasibility Study,Transport Technologies and Sustainable Fuels,CSIRO Energy Transformed Flagship Private Bag 1,Aspendale, Vic. 3195,AUSTRALIA Dr R C Panda (MTech& PhD(IITM);Ex-Faculty (Curtin Univ Tech, Perth, Australia))Scientist CLRI (CSIR), Adyar, Chennai - 600 020,India Miss Jing He PH.D. Candidate of Georgia State University,1450 Willow Lake Dr. NE,Atlanta, GA, 30329 Jeremiah Neubert Assistant Professor,MechanicalEngineering,University of North Dakota Hui Shen Mechanical Engineering Dept,Ohio Northern Univ. Dr. Xiangfa Wu, Ph.D. Assistant Professor / Mechanical Engineering,NORTH DAKOTA STATE UNIVERSITY SeraphinChallyAbou Professor,Mechanical& Industrial Engineering Depart,MEHS Program, 235 Voss-Kovach Hall,1305 OrdeanCourt,Duluth, Minnesota 55812-3042 Dr. Qiang Cheng, Ph.D. Assistant Professor,Computer Science Department Southern Illinois University CarbondaleFaner Hall, Room 2140-Mail Code 45111000 Faner Drive, Carbondale, IL 62901 Dr. Carlos Barrios, PhD Assistant Professor of Architecture,School of Architecture and Planning,The Catholic University of America

Y. BenalYurtlu Assist. Prof. OndokuzMayis University Dr. Lucy M. Brown, Ph.D. Texas State University,601 University Drive,School of Journalism and Mass Communication,OM330B,San Marcos, TX 78666 Dr. Paul Koltun Senior Research ScientistLCA and Industrial Ecology Group,Metallic& Ceramic Materials CSIRO Process Science & Engineering Dr.Sumeer Gul Assistant Professor,Department of Library and Information Science,University of Kashmir,India Dr. ChutimaBoonthum-Denecke, Ph.D Department of Computer Science,Science& Technology Bldg., Rm 120,Hampton University,Hampton, VA 23688


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 Dr. Renato J. Orsato Professor at FGV-EAESP,Getulio Vargas Foundation,São Paulo Business School,RuaItapeva, 474 (8° andar)01332-000, São Paulo (SP), Brazil Dr. Wael M. G. Ibrahim Department Head-Electronics Engineering Technology Dept.School of Engineering Technology ECPI College of Technology 5501 Greenwich Road - Suite 100,Virginia Beach, VA 23462 Dr. Messaoud Jake Bahoura Associate Professor-Engineering Department and Center for Materials Research Norfolk State University,700 Park avenue,Norfolk, VA 23504 Dr. V. P. Eswaramurthy M.C.A., M.Phil., Ph.D., Assistant Professor of Computer Science, Government Arts College(Autonomous), Salem-636 007, India. Dr. P. Kamakkannan,M.C.A., Ph.D ., Assistant Professor of Computer Science, Government Arts College(Autonomous), Salem-636 007, India. Dr. V. Karthikeyani Ph.D., Assistant Professor of Computer Science, Government Arts College(Autonomous), Salem-636 008, India. Dr. K. Thangadurai Ph.D., Assistant Professor, Department of Computer Science, Government Arts College ( Autonomous ), Karur - 639 005,India. Dr. N. Maheswari Ph.D., Assistant Professor, Department of MCA, Faculty of Engineering and Technology, SRM University, Kattangulathur, Kanchipiram Dt - 603 203, India. Mr. Md. Musfique Anwar B.Sc(Engg.) Lecturer, Computer Science & Engineering Department, Jahangirnagar University, Savar, Dhaka, Bangladesh. Mrs. Smitha Ramachandran M.Sc(CS)., SAP Analyst, Akzonobel, Slough, United Kingdom. Dr. V. Vallimayil Ph.D., Director, Department of MCA, Vivekanandha Business School For Women, Elayampalayam, Tiruchengode - 637 205, India. Mr. M. Moorthi M.C.A., M.Phil., Assistant Professor, Department of computer Applications, Kongu Arts and Science College, India PremaSelvarajBsc,M.C.A,M.Phil Assistant Professor,Department of Computer Science,KSR College of Arts and Science, Tiruchengode Mr. G. Rajendran M.C.A., M.Phil., N.E.T., PGDBM., PGDBF., Assistant Professor, Department of Computer Science, Government Arts College, Salem, India. Dr. Pradeep H Pendse B.E.,M.M.S.,Ph.d Dean - IT,Welingkar Institute of Management Development and Research, Mumbai, India Muhammad Javed Centre for Next Generation Localisation, School of Computing, Dublin City University, Dublin 9, Ireland Dr. G. GOBI Assistant Professor-Department of Physics,Government Arts College,Salem - 636 007 Dr.S.Senthilkumar Post Doctoral Research Fellow, (Mathematics and Computer Science & Applications),UniversitiSainsMalaysia,School of Mathematical Sciences, Pulau Pinang-11800,[PENANG],MALAYSIA. Manoj Sharma Associate Professor Deptt. of ECE, PrannathParnami Institute of Management & Technology, Hissar, Haryana, India RAMKUMAR JAGANATHAN Asst-Professor,Dept of Computer Science, V.L.B Janakiammal college of Arts & Science, Coimbatore,Tamilnadu, India Dr. S. B. Warkad Assoc. Professor, Priyadarshini College of Engineering, Nagpur, Maharashtra State, India Dr. Saurabh Pal Associate Professor, UNS Institute of Engg. & Tech., VBS Purvanchal University, Jaunpur, India Manimala Assistant Professor, Department of Applied Electronics and Instrumentation, St Joseph’s College of Engineering & Technology, Choondacherry Post, Kottayam Dt. Kerala -686579


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 Dr. Qazi S. M. Zia-ul-Haque Control Engineer Synchrotron-light for Experimental Sciences and Applications in the Middle East (SESAME),P. O. Box 7, Allan 19252, Jordan Dr. A. Subramani, M.C.A.,M.Phil.,Ph.D. Professor,Department of Computer Applications, K.S.R. College of Engineering, Tiruchengode - 637215 Dr. SeraphinChallyAbou Professor, Mechanical & Industrial Engineering Depart. MEHS Program, 235 Voss-Kovach Hall, 1305 Ordean Court Duluth, Minnesota 558123042 Dr. K. Kousalya Professor, Department of CSE,Kongu Engineering College,Perundurai-638 052 Dr. (Mrs.) R. Uma Rani Asso.Prof., Department of Computer Science, Sri Sarada College For Women, Salem-16, Tamil Nadu, India. MOHAMMAD YAZDANI-ASRAMI Electrical and Computer Engineering Department, Babol"Noshirvani" University of Technology, Iran. Dr. Kulasekharan, N, Ph.D Technical Lead - CFD,GE Appliances and Lighting, GE India,John F Welch Technology Center,Plot # 122, EPIP, Phase 2,Whitefield Road,Bangalore – 560066, India. Dr. Manjeet Bansal Dean (Post Graduate),Department of Civil Engineering,Punjab Technical University,GianiZail Singh Campus,Bathinda -151001 (Punjab),INDIA Dr. Oliver Jukić Vice Dean for education,Virovitica College,MatijeGupca 78,33000 Virovitica, Croatia Dr. Lori A. Wolff, Ph.D., J.D. Professor of Leadership and Counselor Education,The University of Mississippi,Department of Leadership and Counselor Education, 139 Guyton University, MS 38677


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

Contents Functional Connectivity of Magnetic Resonance Imaging of the Brain in Moving Subjects using Fetal, Neonatal and Adult Brain ……………………..…...[ 828]


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

Functional Connectivity of Magnetic Resonance Imaging of the Brain in Moving Subjects using Fetal, Neonatal and Adult Brain Dr. V. K. Narendira Kumar Assistant Professor of Computer Science, Gobi Arts & Science College (Autonomous), Gobichettipalayam, Erode District, Tamil Nadu, India. Email ID: kumarmcagobi@gmail.com Abstract — Brain MRI, a safe and painless test that produces detailed images of the brain and the brain stem, can help detect cysts, tumors, bleeding, and other problems. In this paper some of the important issues regarding the acquisition and reconstruction of anatomical and DTI imaging of moving subjects are addressed; methods to achieve high resolution and high Signal to Noise Ratio (SNR) volume data. Excellent fetal brain 3D Apparent Diffusion Coefficient maps in high resolution have been achieved for the first time as well as promising Fractional Anisotropy maps. Growth curves for the normally developing fetal brain have been devised by the quantification of cerebral and cerebellar volumes as well as someone dimensional measurements. A Verhulst model is to describe these growth curves, and this approach has achieved a correlation over 0.99 between the fitted model and actual data. Keywords: Brain, MRI, Registration, Fetal, Neonatal, Adult.

I. INTRODUCTION Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to form pictures of the anatomy and the physiological processes of the body in both health and disease. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves to generate images of the organs in the body. Magnetic Resonance Imaging (MRI) has proved to be one of the most important and valuable imaging modalities that produce high quality clinical images in a noninvasive way. MRI of the central nervous system (CNS), especially the brain, is attracting the most interest both anatomically and functionally. Despite many well established MR techniques targeting various pathologies, technical obstacles remain in certain situations, for example, imaging subjects under motion. During standard MR scanning, especially brain examinations, the patient are normally required to keep still. However, this is onerous for patients with specific diseases, e.g., dementia, especially when scanned with sequences that require several minutes’ acquisition. Moreover, it is also very difficult for the pediatric patients to keep still without sedation. Even with sedation, those patients especially the neonates may be disturbed or woken up by noisy scanning sequences [2]. Most specifically, in-utero fetal

828

MR imaging is very vulnerable to both the unintentional motion of the fetus itself and the mother’s respiration. Therefore, although highly desirable, there is currently no imaging technique from any imaging modality that can achieve high resolution volumetric imaging of the fetal brain. Besides anatomical MR imaging, motion will also cause severe problems to functional imaging. For instance, motion can invalidate diffusion tensor estimation in Diffusion Tensor Imaging (DTI). Motion will also bring error in functional MRI (fMRI) parameter, especially when there is intra-volume motion [8]. An approach to acquisition and reconstruction of anatomical and DTI MR imaging suitable for use on moving subjects is developed; methods to achieve high resolution and high SNR volume data are proposed. They have been applied successfully for brain studies on subjects that cannot stay still; and in some cases were moving substantially during scanning. For example, awake neonates, confused or distressed adults and, especially fetuses, for which no conventional high resolution 3D method is currently available. A. Background Theory of MRI Magnetic resonance imaging is of immense use in clinical practice for producing anatomical and functional images to aid diagnosis as a powerful non-invasive medical imaging technique. Bloch and Purcell discovered the nuclear magnetic resonance phenomenon independently in 1946. Its use in image formation was not demonstrated until 1973 but by the early 1980s diagnostically useful images were being produced. Introduce the basic principles of magnetic resonance imaging which can be found in a number of texts. Then, a number of sequences, which have been used to acquire data for various facets of this work, are detailed [4]. B. Existing Challenges MRI has been widely adopted clinically as a crucial supplement for ultrasound in in-utero fetal examination especially for pathologic diagnosis. Techniques have been developed since 1983 to allow the early development of human brain to be studied in

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 superior detail as described in previous sections. However, many challenges remain [5]. Anatomical Imaging: The unpredictable fetal motion has led to widespread use of single shot techniques, e.g. the ssTSE sequence, to freeze fetal motion and get a series of high quality 2D slices. However, in a conventional clinical exam, resolution and slice thickness are generally compromised to maintain signal-to-noise ratio (SNR). In addition, although parallel slices are prescribed in the scanner coordinates, the anatomical brain slices obtained are frequently inconsistent because of changes in fetal position between shots. It is therefore generally not possible to combine multiple slices into a self consistent view of the 3D brain. Functional Imaging: An even greater challenge is inutero Diffusion Weighted Imaging (DWI) and Diffusion Tensor Imaging (DTI). This is mainly due to the technical barrier in the conventional diffusion weighted sequence that is highly sensitive to fetal motion and maternal respiration. Motion not only produces various artifacts in the diffusion weighted images, but also invalidates the evaluation of the diffusion tensor matrix, and of course, the ADC and FA values. Therefore, to increase the SNR, a large voxel size has to be used. However, high resolution because of the tiny size of fetal brain is very desirable to achieve better localization of the response [1].

C. Registration and Reconstruction Algorithm The multi-slice data was separated into N separately acquired packages containing spatially separated 2D slices and each package was treated as an independent set of samples of the same rigid body object. One package that is most consistent and has least motion artifact is selected as the target for co-registering each package together at first. All the gap slices in each package are interpolated using cubic B-spline interpolation, thus making N synthesized volumes of the subject imaged under different spatial orientations [8]. Volume-to-volume rigid body registration using gradient decent as the optimization method was implemented here to co-register these synthetic volumes. Then, these packages of interleaved slices but not these synthetic volume were then reconstructed together into a single volume using a scattered data interpolation algorithm based on multilevel b-spline interpolation with control point spacing in the through slice direction set to equal the slice gap in a single package. This results in a mean brain volume image that can be used as a registration target for each package. In all cases final reconstruction uses control points spaced at half the acquired resolution both in plane and through slice as this has been found to provide an effective balance of resolution and signal to noise ratio [6]. D. Subjects and Scanning protocols

II. METHODOLOGY In this paper, an approach to acquisition and reconstruction of anatomical and DTI MR imaging suitable for use on moving subjects is developed; methods to achieve high resolution and high SNR volume data are proposed. They have been applied successfully for brain studies on subjects that cannot stay still; and in some cases were moving substantially during scanning. For example, awake neonates, confused or distressed adults and, especially fetuses, for which no conventional high resolution 3D method is currently available. A. Acquisition Details For ex-utero scanning, including neonatal, pediatric and adult scanning, three multi slice sequence variations with either T2 weighted or dual echo achieving both T2 and Proton Density weighted imaging were set up on a 3.0 T Philips Achieva scanner using an 8 channel SENSE head coil B. Subjects This method has been tested on 11 neonatal subjects with multi slice T2 sequence as well as 6 adult data from the IXI cohort of normal volunteers with a dual echo sequence. Motion artifacts like spatial inconsistency in the through slice direction and aliasing were quite obvious in the original acquired image. For ex-utero scans, segmenting the brain from non-brain tissue is not needed, therefore, this is a fully automatic process.

829

Fetal brain images were acquired on a 1.5 T Philips Achieva scanner (Best, The Netherlands) using a 5 channel torso array with a spin echo planar diffusion tensor sequence. The fetal brain images were preprocessed to isolate the region containing the head from the womb using a Semi-automated segmentation method. We first segment one loop of the fetal brain by roughly tracing the edge of the head manually to exclude maternal tissues. For a fetal data set consisting of 72 slices, the whole process takes around 20 minutes using Image. The fetal brain is then extracted from all the other images using registration based segmentation. This segmentation is later refined by interleaving it with the registration process used to determine slice alignment, allowing both registration and segmentation to be iteratively improved. All slices were inspected and the slices that were corrupted by in-plane motion were excluded before registration and reconstruction. A high resolution anatomical volume acquired with T2-W single short Turbo Spin Echo (ssTSE) dynamic sequence as described in SVR was also reconstructed for comparison. E. SVR Method To achieve high resolution 3D brain images of the fetal brain we have developed a complementary approach that uses dynamic single shot scanning to sample the spatial

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 region containing the brain with multiple overlapping slices. Image registration is then used to retrospectively align the images obtained based on the assumption that they represent a single rigid body undergoing an unknown motion. Having determined the correct location of each image in a self consistent anatomical space of the fetal brain, we regard the measured voxel intensities from all the slices as valid samples at known although irregularly spaced locations and use a scattered interpolation approach to reconstruct an optimal estimate of the 3D fetal brain [1].

For registration of the adult and neonatal data, the same algorithm was used with different rotation ranges for each stage, since the head motion generally covers a smaller range of translations and rotations than for the fetus. Therefore, after initial volume-to-volume registration, a narrower range of rotations was adopted (e.g. -9 to 9 degree or -6 to 6 degree), and some stages with intermediate numbers of slices could be skipped to save computational time. If severe motion does occur, strictly following the fetal registration scheme provides excellent results.

We term this concept of using dynamic single shot slice by slice imaging combined with retrospective alignment and data fusion to produce self consistent 3D volume images Snapshot MRI with Volume Reconstruction or SVR. Although inspired by fetal scanning it has wide application to imaging moving objects that can be assumed to have a constant shape, particularly when there may be other objects in the field of view that undergo differential motion and/or changes in shape. We have therefore tested the method in the general context of imaging the brains of subjects who cannot remain sufficiently still for conventional MRI examinations.

B. Test Data for Registration and Reconstruction

III. IMPLEMENTATION OF THE MRI SYSTEM Fetal brain images were acquired on a Philips 1.5T Intera system. Test data and images of the brains of neonates, children and adults were acquired at 3T. The basic sequence uses ssTSE methods with half Fourier data collection to acquire multiple T2 weighted 2D slices. The imaging was performed as dynamic loops with the scanner operating continuously to acquire parallel slices at a rate of about 1/second. The scans were specified as loops of continuous and overlapping slices with slice thickness 2H and slice gap –H to allow slice separation H and achieve dense sampling as described before. Slices were acquired in 4 packages and within each packages starting at one extreme end in an interleaved order, For a slice acquisition rate of ~1/sec with 60 slices covering the region of interest the total loop time would be 60 seconds and for each acquired slice the closest slices were excited at least 15 seconds previously or subsequently so that the relaxation history in the vicinity of the current slice is effectively uniform. A. Registration Algorithm The method requires individual 2D slices to be registered to a 3D volume. This is a difficult problem, particularly in the premature brain which has less complex patterns of sulcation than adult brains. The rigid body transformations are specified by 6 parameters: 3 rotations and 3 translations; therefore, the optimization takes place in high dimensional space: R6. The problem present here is actually a global optimization. Therefore, the method used should ideally be tuned for the particular problem at hand - in this case, slice to volume registration using fetal brain MR images [8].

830

In order to test the accuracy of slice-to-volume registration, we first used a set of adult MR images scanned with a T2-W ssTSE protocol using a T/R head coil. Each of the individual slices was registered to the target volume using slice-to-volume registration. To test the reconstruction accuracy a set of scattered data samples was created by sampling the gold standard object at random positions in all three dimensions. The number of samples was 8 times the number of gold standard voxels and the maximum sample separation was equal to the gold standard voxel size, so the data was both over-sampled and dense [6]. This scattered data was then reconstructed onto a regular grid using the multilevel scattered data approximation and compared with the gold standard. For both the registration and reconstruction tests noise was added to the gold standard data to recreate SNR levels similar as that of the actual fetal scans at 1.5T. To cover the entire neonatal brain required 72 slices for each loop in the transverse orientation, 80 slices for each loop in the coronal orientation and 64 slices for each loop in the sagittal orientation to be synthesized [8]. the introduction of new mathematic theories, such as compressed sensing, may help improve the efficiency of advanced postprocessing methods and make them applicable in clinical practice. C. SNR Test The effect of data compounding and of the reconstruction on SNR and resolution were also tested with the neonatal dataset. Four copies of the data were created with regular samples at unit intervals, but shifted progressively by 1/4 of a slice thickness in the slice direction and with independent Gaussian noise added [8]. Another numerical experiment was performed by adding independent Gaussian noise with increasing STD to the synthesized motion corrupted neonatal dataset to create data sets with SNR 11, 8.3 and 6.7 corresponding to SNR values for slice thicknesses of 3.3mm, 2.5mm and 2mm respectively at typical 1.5T performance. These data were then reconstructed by SVR and compared to the original data [7]. Finally motion corrupted fetal, neonatal and adult data sets were each reconstructed by SVR using a final lattice control point spacing of 0.5L (L = slice spacing in the scanner frame). The reconstruction programs were written in C++ and processing was done on a 1GHz Pentium PC.

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 IV. EXPERIMENTAL RESULTS Tests of the registration accuracy using synthesized motion corrupted data consisting of 4 loops in a transverse orientation with each slice undergoing a different rigid motion showed that all 249 slices were positioned accurately with cross correlation values above 0.93 after the final registration step. We found that these results were robust to the SNR of the individual images and the noise in the reconstructed image was almost Gaussian as well. SVR reconstruction also preserved the original high resolution of the source slice data, while making the whole volume consistent in space as well as increasing the SNR. Two profiles at corresponding edges of both reconstructed volume and original slice are shown in Figure 1 (j-k) allowing direct visual comparison. This qualitative test confirms that edge sharpness in anatomy is well preserved as well [5]. ➢

➢ ➢ ➢

Figure 1 (a)-(c) are acquired fetal MR transverse data viewed in Transverse, Coronal and Sagittal planes with 1.25mm.1.25mm in-plane resolution and 2.8mm TH. Figure 1 (d)-(f) are the corresponding views for averaged images from the full dynamic scan before motion correction. Figure 1 (g)-(i) are the corresponding views reconstructed to 1.25mm isotropic resolution image after registration. Figure 1 (j)-(k) are measured edge profiles of original acquired slice (marked as white line in (a)) and corresponding position at reconstructed image (marked as white line in (g)).

However, the 3T acquired data on adult brain we found that changing slice orientation resulted in differences in the data that introduced errors larger than the registration uncertainties. We interpret this result as evidence of slice distortion caused by changing interactions between the image encoding gradients and background susceptibility effects caused by the subject being in the scanner. In the adult brain data we collected we did not find this a significant problem at the lower field like 1.5T. We did not detect any slice distortion effects in the fetal data acquired, however since there is no motion free reference in this case we cannot rule this out [6]. A. Fetal Results All twenty fetal datasets were successfully reconstructed. Two examples are illustrated here to display reconstructed results with different acquired slice thickness and with only parallel slices or slices from all three orthogonal orientations. Figure 1 shows data from a fetus of 33 weeks gestation scanned using 4 dynamic loops of 60. 2.5mm slices prescribed as nominally in the transverse orientation. Figure 2 shows data from a less mature fetus of 28 gestation weeks combining 4-loops of transverse, 2-loops of coronal and 2-loops of sagittal slices with slice thickness 2.5mm and 1.25mm slice separation. In these figures, the top row shows a single loop of the original fetal image data in a 3-plane view (transverse, coronal and sagittal) [3]. Although the native (transverse) plane is as expected, the other views reveal motion corruption. Simply combining all the acquired slices without correcting for fetal motion resulted in blurred images (second row in Figure 1 - Figure 2).

Figure 1 (l)-(n) are the corresponding views of a preterm neonate born at 28 weeks and scanned at 34 week with 0.98.0.98mm in-plane resolution and 1 mm TH.

Fig. 2: Result for a normal fetus of 28 week gestational age. Fig. 1: Result for a normal fetus of 33 week gestational age.

831

Figure 2 (a)-(c) are acquired fetal MR transverse data viewed in Transverse, Coronal and Sagittal planes

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

➢ ➢ ➢

with 1.25mm.1.25mm in-plane resolution and 2.5mm TH. Figure 2 (d)- (f) are the corresponding views for averaged images from the full dynamic scan before motion correction. Figure 2 (g)- (i) are the corresponding views reconstructed to 1.25mm isotropic resolution image after registering slices from 3 orthogonal orientations. Figure 2 (j)- (l) are the corresponding views of a preterm neonate born at 28 week and scanned at 30 week with 0.98.0.98mm in-plane resolution and 1 mm TH [8].

At the final stage of image registration, Data 1 (Figure 1) uses 208 slices and Data2 (Figure 2) uses 327 slices. In each case a 1.25 mm isotropic reconstruction of a 3D self-consistent volume with improved SNR and high contrast between cortical grey and white matter is produced. Details of cortical folding and small structures in the cerebella are well displayed in all three planes (third row in Figure 1- Figure 2). Additionally, when compared to preterm born infants scanned at similar gestational age but at 3 Tesla (last row in Figure 1 - Figure 2), strong correlations in brain anatomy including cortical folding, deep white matter tracts and cerebellar structures can be found [2]. B. Adult Results This method can also be applied to other brain studies in both children and adults, wherever motion is a problem. This has been first tried on an adult volunteer study in which the subject deliberately moved about once per second, including making head rotations of up to 15. For comparison, images were also acquired with the same protocol while the subject was still. Because of this intense motion, some slice images were found to be degraded by movement during the single shot it [7].

All the slices that were not corrupted by in plane motion were accurately registered and used for reconstructing a 1.0.1.0.1.4 mm volume, which is almost identical to the motion free image with doubled SNR as displayed in Figure 3. Thus even in this extreme case, the method is able to recover detailed artifact free images [9]. ➢

➢ ➢

Figure 3 (a)-(c) are acquired MR transverse data viewed in Transverse, Coronal and Sagittal planes with 1.0 mm.1.0 mm in-plane resolution and 2.8 mm TH. Figure 3 (d)-(f) are the corresponding views reconstructed to a 1.0.1.0.1.4 mm resolution image after registration. Figure 3 (g)-(i) are the corresponding views of the same volunteer scanned with the same protocol but stayed still. Reduced coverage is realized because of limitation of scanning time.

The reconstruction has successfully achieved 3D coherent volume with both high resolution and almost doubled SNR despite of totally motion corrupted input data [6]. Alternative approaches focus on truncation of sampled data to decrease scanning time. Parallel imaging introduced by Sodickson and Manning51 in 1997 (simultaneous acquisition of spatial harmonics) and Pruessmann et al52 in 1999 (sensitivity encoding) has revolutionized MR imaging by its ability to speed up data acquisition by using multiple receiver coils to obtain extraspatial information. This can reduce the number of phase-encode steps required to form an image and can be applied to most sequences. Scanning times can be reduced significantly on the basis of the operator-selected speed-up factor. Speed-up factors of 2 halve total scanning time, without the introduction of artifacts but with some reduction in SNR. However, dedicated phased array coils are required to implement parallel imaging techniques [11]. Half-Fourier acquired single-shot turbo spin-echo, introduced by Margosian et al53 in 1986, is a single-shot technique combined with FSE, which measures only half the lines of k-space and makes use of the inherent theoretic symmetry of k-space to regenerate the other half, plus a few extra lines to correct imperfections. This method has been extensively applied in fetal brain imaging. There are similar techniques, such as partial (fractional) echo, in which a fraction of the generated echo is collected (the length of the readout is reduced) and the rest of the data is regenerated on the basis of echo symmetry. All the above-mentioned techniques manage to decrease total scanning time, often at a cost of image quality, and to minimize the likelihood of motion artifacts occurring during the scanning. However, they do not truly correct for motion; so motion artifacts will still appear and images will be affected in the event of patient motion during the shortened data acquisition.

Fig. 3: Results for Adult volunteer that deliberately moved during scanning

832

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 C. Neonatal Results A general application of SVR can be found in pediatric MR scanning including both neonates, who may move during natural sleep or sedation and young children who have difficulty staying still during scanning. By prescribing the slices as overlapped in their native planes, there is full sampling even if the subject does not move. This method can correct motion for each 2D slice and then achieve 3D coherent imaging with 1mm isotropic resolution and almost doubled SNR [12].

Fig. 4: Results for a neonate of 43 week GA who was unsettled in light sleep and moving during the scanning.

We scanned at 3T with the top-bottom direction as the slice select direction [10]. ➢ ➢ ➢

Figure 4 (a) Shows one loop of ssTSE dynamic scan when the neonates is moving. Figure 4 (b) Shows the reconstruction with 4 loops of ssTSE dynamic scan that achieved both coherent imaging and improved SNR. Figure 4 (c) Show an acquisition with a TSE sequence with subject being still. Although the subject was sedated, some motion artifacts that make structures slightly in-consistent are still visible as highlighted in the rectangle regions (basal ganglia, cerebella, and frontal cortex) in Figure 4 (i). The result compares well with the conventional multishot images acquired before the baby woke up. It is a high-fidelity reconstruction that is nearly identical when compared to actually required image when it was almost still (Figure 4, bottom row).

Motion degrades magnetic resonance (MR) images and prevents acquisition of self-consistent and highquality volume images. A novel methodology, Snapshot magnetic resonance imaging (MRI) with Volume Reconstruction (SVR) has been developed for imaging moving subjects at high resolution and high signal-to-

833

noise ratio (SNR). The method combines registered 2-D slices from sequential dynamic single-shot scans. The SVR approach requires that the anatomy in question is not changing shape or size and is moving at a rate that allows snapshot images to be acquired. After imaging the target volume repeatedly to guarantee sufficient sampling everywhere, a robust slice-to-volume registration method has been implemented that achieves alignment of each slice within 0.3 mm in the examples tested. Multilevel scattered interpolation has been used to obtain highfidelity reconstruction with root-mean-square (rms) error that is less than the noise level in the images. The SVR method has been performed successfully for brain studies on subjects that cannot stay still, and in some cases were moving substantially during scanning. For example, awake neonates, deliberately moved adults and, especially, on fetuses, for which no conventional high-resolution 3-D method is currently available. Fine structure of the in-utero fetal brain is clearly revealed for the first time and substantial SNR improvement is realized by having many individually acquired slices contribute to each voxel in the reconstructed image [13]. The first contribution of this work concerns the use of a SR framework for HR 3D isotropic fetal brain MR image reconstruction. Contrary to previous works [4,5,6] where sparse interpolation frameworks were used, an observation model is introduced in this paper in order to truly take into account physics of MR image acquisition (point spread function, sub-sampling and noise). This model allows potentially to recover fine image details compared to interpolation based approaches. Visual analysis of the obtained results on real data are very encouraging. Such high resolution image reconstruction algorithm represents an important step towards analysis of fine scale anatomical details [14]. The second contribution of this paper is the study of the sufficient number of LR images based on simulations using the Brain web images. Considering a set of orthogonal stack of 2D slices with an anisotropic resolution of 1 × 1 × 3mm, the sufficient number of LR images is three in the case of noise free images. When adding Gaussian noise, the sufficient number of LR inputs is less than 9. Including an efficient denoising step in the overall image processing pipeline should lead to a significant decrease of the number of required LR images. As a consequence, further work is to investigate the building of such pipeline in order to reduce the fetal imaging time [15]. Motion during data acquisition causes data to be inconsistent. The final MR image and the raw data, or kspace data, are related by the Fourier transform so that each pixel of the image is composed of a weighted sum of every k-space point and each k-space point contains a weighted sum of signals from every point in the region of the object being imaged; therefore, any inconsistency in k-space data sampling has the potential to affect every pixel in the resulting MR image.26,27

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020 There are essentially 2 ways in which data inconsistencies due to motion may produce artifacts 24: 1) intra-view (or within view) effects are caused by motion occurring between each RF pulse excitation and echo formation, and 2) inter-view (or view-to-view) effects are caused by motion occurring between the acquisition of successive phase-encoding steps. Interview effects result in phase errors due to the inconsistent location and signal intensity of the moving spins during phase-encoding, while intra-view effects result in phase incoherence among the moving spins at the time of echo formation. When intra-view effects take place, signal loss due to dephasing or spatial misregistration may occur. When inter-view effects occur and motion is periodic (such as with respiration), ghosting artifacts appear on MR images. Similarly, when inter-view effects are present and motion is random, image blurring degrades MR images. Both blurring and ghosting artifacts are mostly evident in the phase-encoding direction, irrespective of the actual direction of motion. This review will focus on inter-view motion effects. Both fetal and neonatal motion is unpredictable, characterized by unique patterns, perhaps the most extreme in the pediatric imaging spectrum. Artifacts from bulk head motion are destructive, may hamper diagnosis and timely intervention, and may require costly repeat scans. Although different methods of motion compensation are available for adults, there are no such techniques dedicated to neonates and fetuses. Adultbased motion-compensation strategies fail to provide satisfactory results unless adjusted to the characteristics and needs of this population.

V. CONCLUSION We have described a novel methodology, SVR, for imaging moving subject at high resolution and high SNR by combining registered 2D slices from sequential dynamic single-shot scans. The SVR method requires that the anatomy in question is not changing shape or size and is moving at a rate that allows snapshot images to be acquired. It has been performed successfully on neonates, adults and especially on fetuses, for which no conventional high resolution 3D method is currently available. Fine structure of the in-utero fetal brain is clearly revealed for the first time and substantial SNR improvement is realized by having many individually acquired slices contribute to each voxel in the reconstructed image. The price of the benefits offered by this technique is increased scan time to allow multiple loops to be acquired. The ability to acquire data with certainty that it will yield artifact free images allows a reduction in set up time and in repeated examinations that can in fact increase examination efficiency. For adult and pediatric subjects the method offers a capability to obtain high quality volume data even when the subject is unable to cooperate with the examination and may be moving by many millimeters or turning by many degrees during the acquisition period. Validation using both adult and neonate simulated data has been performed to verify that the results obtained are consistent with the known ground truth and the reconstruction is found to be faithful.

The effort to customize these techniques is triggered by the growing clinical interest in fetal and neonatal MR imaging and its increasing use as a biomarker and a surrogate outcome measure in clinical trials. Parallel imaging, along with prospective motion-correction techniques with fast navigator echoes and time-efficient reconstruction, seems to hold promise for advancing inter-view motion correction. Compensation for intra-view motion will also be vital to facilitate diffusion tensor imaging and functional MR imaging studies. NonCartesian k-space trajectories also show promising results, particularly because of the low spatial-frequency oversampling in k-space in the otherwise “SNR-starved� fetal and neonatal MR images. These efforts are backed by hardware improvements, such as high-field imaging, faster and stronger gradients, advancing coil design, and transmit coil technology. Additionally, the introduction of new mathematic theories, such as compressed sensing, may help improve the efficiency of advanced postprocessing methods and make them applicable in clinical practice. Motion compensation holds a very central role in neonatal and fetal MR imaging. Promising results rely on fine-tuning of the available methods to suit this population and often on using them in combination.

834

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

REFERENCES [1] Adamsbaum,C., (2011). - Myelin characterization of fetal brain with mono-point estimated T1-maps. Magn Reson. Imaging 22, 565-572. [2] Bydder,G.M. (2001). Diffusion-weighted imaging of the brain in neonates and infants. Magn Reson. Imaging Clin. 83-98, [3] Chang,C.H., (2000). Assessment of fetal cerebellar volume using three-dimensional ultrasound. Ultrasound Med. Biol. 981-988. [4] Chen,Q. (2001). Fast fetal magnetic resonance imaging techniques. Top. Magn Reson. Imaging 12, 67-79. [5] Sands,J. (2011). Quantitative growth and development of human brain. Arch. Dis. Child 48, 757-767. [6] Glover,G.H (2002). Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson. Med. 28, 275-289. [7] Grossman,R., (2006). Quantitative MRI measurements of human fetal brain development in utero. Neuroimage. 463470. [8] Jenkinson,M., (2002). Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage. 17, 825-841. [9] Griffiths PD, Paley MN, Whitby EH. MR imaging of the fetal brain and spine: a maturing technology. Ann Acad Med Singapore 2003;32:483–89 [10] Prayer D. Fetal MR. Eur J Radiol 2006;57:171 [11] Huppi PS, Inder TE. Magnetic resonance techniques in the evaluation of the perinatal brain: recent advances and future directions. Semin Neonatol 2001;6:195–210 [12] Edwards AD, Azzopardi D, Rutherford MA. Evaluation of MR imaging to predict neurodevelopmental impairment in preterm infants (e-prime). National Institute for Health Research Annual Report 2009 (http://www.nihr.ac.uk/files/pdfs/400891_NIHR_AnnualRe port2010−acc3.pdf). Accessed September 14, 2011 [13] Levine D. Ultrasound versus magnetic resonance imaging in fetal evaluation. Top Magn Reson Imaging 2001;12:25– 38 [14] Hayat TT, Nihat A, Martinez-Biarge M, et al. Optimization and initial experience of a multisection balanced steadystate free precession cine sequence for the assessment of fetal behavior in utero. AJNR Am J Neuroradiol 2011;32:331–38. [15] Chow LC. Motion correction for pediatric and MSK MRI. In: Proceedings of the International Society of Magnetic Resonance in Medicine Workshop on Current Concepts of Motion Correction for MRI & MRS, Kitzbuhel, Tyrol, Austria. February 24–28, 2010.

835

Author Profile Dr. V.K. NARENDIRA KUMAR M.C.A., M.Phil., Ph.D., Assistant Professor, PG & Research Department of Computer Science Gobi Arts & Science College (Autonomous), Gobichettipalayam – 638 453, Erode District, Tamil Nadu, India. He received his Ph.D. Degree in Computer Science from Bharathiar University in 2018. He has authored or co-authored more than 80 National, International Journal Papers, Technical Papers and Conference Presentations. He is an editorial board member of two International Journals and Eleven National Journals. His research interests are focused on network security, image processing, video processing, visual human-computer interaction, and biometrics technologies.

www.ijitce.co.uk


INTERNATIONAL JOURNAL OF INNOVATIVE TECHNOLOGY AND CREATIVE ENGINEERING (ISSN:2045-8711) VOL.10 NO.8 AUGUST 2020

836

www.ijitce.co.uk


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.